AS=12

Dec 2008

Wyo.

2202016

Proj.

Sheet

B33

of

B128

Sheets

CONCRETE RETAINING WALL


STA 40 I50 STA 43 I
60
WORLAND STREETS
WEST RIVER ROAD & BIG HORN CANAL
2202016

WASHAKIE COUNTY

DESIGN DATA
SPECIFICATIONS: AASHTO LRFD Bridge Design Specifications, 4th Edition

ESTIMATED QUANTITIES
ITEM NO.

ITEM

REINFORCED CONCRETE: Load and Resistance Factor Design UNIT

TOTAL
QUANTITY

f y=40,000 psi (Grade 40)

209.01000

WATER

MG

125

212.02100

DRY EXCAVATION

CY

6550

212.02200

WET EXCAVATION

CY

490

301.01020

CRUSHER RUN SUBBASE

TON

8032

513.00015

CLASS B CONCRETE

LS

LUMP SUM

610.8 CY

514.00015

REINFORCING STEEL

LS

LUMP SUM

65,230 LB

900.60000

CONTRACTOR QUALITY CONTROL (CONCRETE)

LS

Class B Concrete f
c =3250 psi
Reinforcing Steel fy =60,000 psi (Grade 60)

ESTIMATE

RETAINING WALL DESIGN DATA


Foundation Material

LUMP SUM

39^

0.81

120 pcf

all

4.0 tsf

SPECIFICATIONS: WYDOT Standard Specifications for Road and Bridge


Construction, 2003 Edition

WATERSTOP: Work necessary for the waterstop is incidental to the


contract pay item Class B Concrete.

26^

85 pcf

0 psf

32^

125 pcf

act

1.66 tsf

REFERENCES
Supplementary Specifications:
SS-500G

Dated

Structural Concrete With Quality Control and


Quality Acceptance

DIMENSIONS: Longitudinal dimensions are horizontal and include no


correction for grade.

Rev 5-2-07

CRUSHER RUN SUBBASE: Use crusher run subbase conforming to


Grading J.

2" unless noted. Dimensions for bent bars are out to out.

WATER: Water at 13.6 gallons per ton has been estimated for
compaction of the crusher run subbase.

BAR MARKS
Straight Bars
Size

Length

Size

Designation

STRUCTURE NO. LVH

DRY EXCAVATION: The estimated quantity of dry excavation is


calculated below the existing ground line to elevation 4072.0.

ML2202B, RM 0.61

508-3

Bent Bars

4.02 - Example

REINFORCING STEEL: Concrete cover to face of reinforcing steel is

4A2

SEC 26, T47N, R93W

WET EXCAVATION: The estimated quantity of wet excavation is


calculated below elevation 4072.0.

WYOMING DEPARTMENT OF TRANSPORTATION

PREFORMED EXPANSION JOINT FILLER: Use preformed expansion joint


filler conforming to AASHTO M 153 Type ?. Work necessary for the
joint filler is incidental to the contract pay item Class B Concrete.

BRIDGE PROGRAM

FOUNDATION: The retaining wall is on a footing founded on dense

REVISIONS

sand and gravel.

APPROVED

Design Section

DESIGN

DATE

DETAIL
QS

JJJ

Q R Stuv

PPP
Drwg. No.

0021

Sheet

of

2202016_2ts.dgn

Section 4.02 - General Notes

GENERAL NOTES

Reinforced
Backfill Material

Retained Soil

Wyo.

Sheet

Proj.

2202016

B34

of

B128

Sheets

City of Worland
Underground
Water Line

| Survey

43+00

41+00

N 0^1200.0" W

End Retaining Wall


Sta 43+60.00

17-4"

RT Communications
Underground
Telephone Line

13-0"

27-4"
3-0"

30-4"

Begin Retaining Wall


Sta 40+50.00

42+00

Wyoming Gas
Underground
Gas Line

FF Wall

Telephone Pole
| Const Jt
RT Communications
Overhead Telephone Line

Footing

| Const Jt

& Exp Jt

| Exp Jt

Pacific Power
& Light Company
Overhead
Power Line

& Exp Jt

90-0"
80-0"

50-0"

90-0"

140-0"

PLAN

Elev 4089.83

Elev 4089.72

Contr
Jt (Typ)

Top of Wall

Elev 4089.29

Approximate Existing
Ground Line at FF Wall

Elev 4088.59

Elev 4088.84

4090

4080

4070
| Const Jt

Bott of Footing

& Exp Jt

4060

80-0" Wall Segment A

| Const Jt

Elev 4070.00

| Exp Jt

& Exp Jt

90-0" Wall Segment B

90-0" Wall Segment C

50-0" Wall Segment D

4050

ELEVATION
WYOMING DEPARTMENT OF TRANSPORTATION
BRIDGE PROGRAM
REVISIONS

GENERAL PLAN AND ELEVATION


CONCRETE RETAINING WALL
STA 40+50 - STA 43+60
Worland Streets
West River Road & Big Horn Canal
Wa

2202016
APPROVED
DESIGN

DATE

DETAIL
QS

PPP
JJJ
MMM

NNN
PPP
NNN

Design Section
Drwg. No.

0021

Q R Stuv
Sheet

of

2202016_2gp.dgn

Section 4.21 - Earth Retaining Structures

310-0"

4.21 - Example

OPW

Dec 2008

OTW

AS=25

AS=12
Dec 2008

Wyo.

Sheet

2202016

B35

of

B128

Sheets

Match Line

460-0 (5 per line)


& 419-3@4 Eq
Spa (Bott)

& 419-3@12"
=12-0" (Top)

460-0 (5 per line)


6"

13-0"

6"

Const Jt
w/2"\8"
Keyway (Typ)

Proj.

712-8@6"=79-6" (Top)
3"

7W1@6"=79-6" (Bott)

712-8@6"=89-6" (Top)
3"

3"

7W1@6"=89-6" (Bott)

80-0"

3"

90-0"

140-0"
310-0"

Match Line

(Typ)

FF Wall

712-8@6"=139-6" (Top)
3"
90-0"

7W1@6"=139-6" (Bott)

3"

140-0"

310-0"

FOOTING PLAN
(Longitudinal keyway not shown)

4.21 - Example

WYOMING DEPARTMENT OF TRANSPORTATION


BRIDGE PROGRAM
REVISIONS

RETAINING WALL DETAILS


CONCRETE RETAINING WALL
STA 40+50 - STA 43+60
Worland Streets
West River Road & Big Horn Canal

Note: Place short leg of 7W1 bars in footing.

Wa

2202016
APPROVED
DESIGN

DATE

DETAIL
QS

PPP
JJJ
MMM

NNN
PPP
NNN

Design Section
Drwg. No.

0021

Q R Stuv
Sheet

of

2202016_2rw1.dgn

Section 4.21 - Earth Retaining Structures

1-11" Lap

AS=8
Dec 2008

Wyo.

Proj.

2202016

80-0"
B36

Sheet

3"

7W2@6"=79-6" (RF)

3"

of

B128

Sheets

30-0"
3"

417-3@12"=79-0" (FF)

3"

A
| Contr Jt

| Exp Jt

| Contr Jt
660-0 (EF)

13-9"

17-5 5/8 "

3-8 5/8 "

622-7 (EF)

@12"=13-0" (EF)

460-0 & 421-7

25-0"

6"

13-9"

17-7"

3"

3-10"

460-0 & 421-7


@12"=2-0" (EF)

25-0"

Wall Segment B

Footing
2-0"

3-0"

ELEVATION - WALL SEGMENT A


1-0"

1-0"

Opt Const Jt w/
2"\4" Keyway

7W2

13-9"

417-3

FF
Wall

460-0 or 421-7

Varies

(3-10" to
3-8 5/8 ")

660-0 or 622-7

Longitudinal
Const Jt w/
2"\8" Keyway

Note: 1) Place 7W2 bars with 7W1 bars.


2) Place 7W2 and 417-3 bars to maintain 2" clearance
from top of wall.
3) Trim contraction joints with 1/2 " bevel strips.

WYOMING DEPARTMENT OF TRANSPORTATION

2-3"

BRIDGE PROGRAM
REVISIONS

460-0 or
419-3

7W1

RETAINING WALL DETAILS


CONCRETE RETAINING WALL

3" Cl

4.21 - Example

712-8

STA 40+50 - STA 46+60


Worland Streets

460-0 or 419-3

West River Road & Big Horn Canal

APPROVED
DESIGN

SECTION A-A

Wa

2202016

13-0"

DATE

DETAIL
QS

PPP
JJJ
MMM

NNN
PPP
NNN

Design Section
Drwg. No.

0021

Q R Stuv
Sheet

of

2202016_2rw2.dgn

Section 4.21 - Earth Retaining Structures

8-0"

AS=8
Dec 2008

Wyo.

Proj.

2202016

90-0"
Sheet

460-0 & 431-7


@12"=2-0" (EF)

3"

7W3@6"=89-6" (RF)

3"
B

B128

Sheets

3"

| Exp Jt

| Contr Jt

| Contr Jt

of

3"

416-10@12"=89-0" (FF)

| Exp Jt

B37

30-0"

660-0 (EF)

13-9"

17-0 1/2 "

3-3 1/2 "

632-7 (EF)

@12"=13-0" (EF)

460-0 & 431-7

30-0"

6"

13-9"

17-5 5/8 "

3"

3-8 5/8 "

30-0"

Wall Segment A

Wall Segment C
Footing
2-0"

3-0"

ELEVATION - WALL SEGMENT B


1-0"

1-0"

Opt Const Jt w/
2"\4" Keyway

7W3

13-9"

416-10

FF
Wall

460-0 or 431-7

(3-8 5/8 "


to 3-3 1/2 ")

Varies

660-0 or 632-7

Longitudinal
Const Jt w/
2"\8" Keyway

Note: 1) Place 7W3 bars with 7W1 bars.


2) Place 7W3 and 416-10 bars to maintain 2" clearance
from top of wall.
3) Trim contraction joints with 1/2 " bevel strips.

WYOMING DEPARTMENT OF TRANSPORTATION

2-3"

BRIDGE PROGRAM
REVISIONS

460-0 or
419-3

7W1

RETAINING WALL DETAILS


CONCRETE RETAINING WALL

3" Cl

4.21 - Example

712-8

STA 40+50 - STA 46+60


Worland Streets

460-0 or 419-3

West River Road & Big Horn Canal

APPROVED
DESIGN

SECTION B-B

Wa

2202016

13-0"

DATE

DETAIL
QS

PPP
JJJ
MMM

NNN
PPP
NNN

Design Section
Drwg. No.

0021

Q R Stuv
Sheet

of

2202016_2rw3.dgn

Section 4.21 - Earth Retaining Structures

8-0"

AS=8
Dec 2008

Wyo.

Proj.

2202016

90-0"
Sheet

460-0 & 431-7


@12"=2-0" (EF)

3"

7W4@6"=89-6" (RF)

3"

B128

Sheets

3"

| Exp Jt

| Contr Jt

| Contr Jt

of

3"

416-5@12"=89-0" (FF)

| Exp Jt

B38

30-0"

660-0 (EF)

13-9"

16-7 1/8 "

2-10 1/8 "

632-7 (EF)

@12"=13-0" (EF)

460-0 & 431-7

30-0"

6"

13-9"

17-0 1/2 "

3"

3-3 1/2 "

30-0"

Wall Segment B

Wall Segment D
Footing

2-0"
1-0"

3-0"

ELEVATION - WALL SEGMENT C

1-0"

Opt Const Jt w/
2"\4" Keyway

7W4

13-9"

416-5

FF
Wall

460-0 or 431-7

(3-3 1/2 "


to 2-10 1/8 ")

Varies

660-0 or 632-7

Longitudinal
Const Jt w/
2"\8" Keyway

Note: 1) Place 7W4 bars with 7W1 bars.


2) Place 7W4 and 416-5 bars to maintain 2" clearance
from top of wall.
3) Trim contraction joints with 1/2 " bevel strips.

WYOMING DEPARTMENT OF TRANSPORTATION

2-3"

BRIDGE PROGRAM
REVISIONS

460-0 or
419-3

7W1

RETAINING WALL DETAILS


CONCRETE RETAINING WALL

3" Cl

4.21 - Example

712-8

STA 40+50 - STA 46+60


Worland Streets

460-0 or 419-3

West River Road & Big Horn Canal

APPROVED
DESIGN

SECTION C-C

Wa

2202016

13-0"

DATE

DETAIL
QS

PPP
JJJ
MMM

NNN
PPP
NNN

Design Section
Drwg. No.

0021

Q R Stuv
Sheet

of

2202016_2rw4.dgn

Section 4.21 - Earth Retaining Structures

C
8-0"

AS=8
Dec 2008

Wyo.

Sheet

Proj.

2202016

B39

of

B128

Sheets

50-0"
25-0"
3"

25-0"
7W5@6"=49-6" (RF)

3"

| Exp Jt

3"

416-2@12"=49-0" (FF)

3"

| Contr Jt

2-7 1/8 "


16-4 1/8 "

13-9"

12"
449-7@12"=13-0" (EF)

449-7 (EF)

6"

16-7 1/8 "

3"

2-10 1/8 "


13-9"

649-7 (EF)

8-0"

2-0"

3-0"

Wall Segment C

1-0"
D

Varies

(2-10 1/8 "


to 2-7 1/8 ")

649-7

ELEVATION - WALL SEGMENT D

Opt Const Jt w/
2"\4" Keyway

449-7

7W5

13-9"

416-2

FF
Wall

Longitudinal
Const Jt w/
2"\8" Keyway

Note: 1) Place 7W5 bars with 7W1 bars.


2) Place 7W5 and 416-2 bars to maintain 2" clearance
from top of wall.
3) Trim contraction joints with 1/2 " bevel strips.

WYOMING DEPARTMENT OF TRANSPORTATION


BRIDGE PROGRAM
REVISIONS

460-0 or 419-3

7W1

RETAINING WALL DETAILS

3" Cl

4.21 - Example

2-3"

712-8

CONCRETE RETAINING WALL


STA 40+50 - STA 46+60

460-0 or 419-3

Worland Streets

13-0"
West River Road & Big Horn Canal
Wa

2202016

SECTION D-D
APPROVED

DESIGN

DATE

DETAIL
QS

PPP
JJJ
MMM

NNN
PPP
NNN

Design Section
Drwg. No.

0021

Q R Stuv
Sheet

of

2202016_2rw5.dgn

Section 4.21 - Earth Retaining Structures

Footing
1-0"

AS=8
X 2008
Dec
2008

Wyo.

2202016

Proj.

B40

Sheet

of

B128

Sheets

BILL OF REINFORCEMENT

419-3

18

Bending Diagrams
3"

Wall

1 3/4

Back Limits
of Excavation

TYPICAL SECTION

7W1

416-10

90

(9-11")

417-3

80

421-7

34

431-7

68

7W2

7W3

449-7

32

(17-4")

(16-11")

460-0

102

622-7

632-7

649-7

660-0

7W2

160

7W3

180

7W4

180

7W5

100

Weight

1/2 " Preformed


Expansion
Joint Filler

4-9 1/2 "

13-9 1/2 "

13-9 1/2 "

90

2 1/4 "

32,772 LB

2-5"

2"

7W4

7W5

(16-6")

(16-3")

| Exp Jt

6"

Note: The estimated quantity of class B concrete for footing is


335.8 CY. The estimated quantity of class B concrete for
wall is 275.0 CY.

4.21 - Example

3/8 "\9" Waterstop


(Place full height of wall)

WYOMING DEPARTMENT OF TRANSPORTATION

FF Wall

BRIDGE PROGRAM
REVISIONS

RETAINING WALL DETAILS

SECTION THRU EXPANSION JOINT


CONCRETE RETAINING WALL
STA 40+50 - STA 46+60
Worland Streets
West River Road & Big Horn Canal
Wa

2202016
APPROVED
DESIGN

DATE

DETAIL
QS

PPP
JJJ
MMM

NNN
PPP
NNN

Design Section
Drwg. No.

0021

Q R Stuv
Sheet

of

2202016_2rw6.dgn

Section 4.21 - Earth Retaining Structures

2-6"

50

416-5

2-5"

416-2

2-8"

Crusher
Run
Subbase

620
32,458 LB

13-9 1/2 "

Approximate
Existing
Ground Line

712-8
Weight

2-8"

Backfill to
match existing
ground line

620

13-9 1/2 "

FF Wall

90

7W1

5-1"

Roadway

460-0

2 3/4 "

"
3-1 1/2

Footing

"
3-6 1/2

| Survey

5-1"

4 1/2 "

3-1 1/2 "

Mark

3-6 1/2 "

Location

27-4"

Number
Required