Professional Documents
Culture Documents
24-FEB-03
EPCE02-20A
HRV
Heat Recovery Ventilation
FA
VAM - FA series
Combined
Air Conditioning
and Ventilation
for Energy Efficiency
and Comfort
mov78452_epce02-20a Page 2
T a b l e
o f
C O N T E N T S
24-FEB-03
mov78452_epce02-20a Page 3
24-FEB-03
I NTRODUCTION
p4
F E AT U R E S O F DA I K I N H RV
First-class compactness in the industry
First-class energy conservation in the industry
Simple design and construction
Cleanliness
p6
p6
p7
p8
p8
C O N T R O L S YST E M S
p9
Centralised control of air conditioning and ventilation
p9
Various control systems according to applications and conditions p 12
page
MODE L LI N E-U P
p 14
DIMENSIONS
p 16
S P E C I F I C AT I O N S
p 18
AC C E S S O R I E S
Installation of accessories
List of accessories
PC board adapter for heater control kit
Direct expansion coil unit
p 19
p 19
p 19
p 20
p 21
mov78452_epce02-20a Page 4
24-FEB-03
Introduction
Daikin's HRV (Heat Recovery Ventilation) recovers heat energy lost
through ventilation and holds down room temperature changes
caused by ventilation, thereby maintaining a comfortable and clean
environment. This also curbs the load on the air conditioning system
and conserves energy.
mov78452_epce02-20a Page 5
24-FEB-03
HRV UNIT
ON/OFF signal
Cooling/Heating mode signal
Set temperature signal
Ventilation signal
Humidifier ON/OFF signal
page
mov78452_epce02-20a Page 6
24-FEB-03
F e a t u r e s o f D a i k i n H RV
VA M - FA s e r i e s
First-class
compactness in
the industry
30%
348mm
page
mov78452_epce02-20a Page 7
24-FEB-03
First-class energy
conservation in
the industry
Return air
Exhaust
air
Outdoor
air intake
Supply air
Outdoor air temperature sensor
Air Conditioning
Load Reduced by
28% on Average
(maximum 40%)
Return air
Exhaust
air
Outdoor
air intake
2 Another approximately 6%
Supply air*
Intermediate season
Outdoor air temperature sensor
gained by auto-ventilation
mode changeover switching
Indoor air
temperature sensor
Note
The values mentioned above may vary according to
weather and other environmental conditions at
the location of the units installation.
page
mov78452_epce02-20a Page 8
24-FEB-03
F e a t u r e s o f D a i k i n H RV
VA M - FA s e r i e s
Simple design
and construction
Switch box
Access door
Maintenance cover
Portion of fresh-up
operation
HRV
Normal
ventilation fan
Air exhaust
HRV
Floor area
Air supply
Air exhaust
Cleanliness
Fresh-up Operation
Air supply
Portion of
exhaust
operation
eg. Office
eg. Hospital
page
Sick room
OFF
Dust
Blowing mode
With HRV
mov78452_epce02-20a Page 9
24-FEB-03
Control
systems
The operation of the air conditioner using its remote control is
interlocked to the operation of the HRV, greatly simplifying overall
system operation. In addition, installation work associated with
the HRV remote control is not necessary because operations for
air conditioning and ventilation are completely centralised on
the air conditioner remote control.
Also, the use of such a centralised remote control allows the user
to choose a wide range of control systems that integrate air
conditioning and ventilation. Furthermore, by using a variety of
centralised control equipment, the user can build a large, highgrade centralised control system.
Centralised
control of air
conditioning
and ventilation
page
Self-diagnosis functions
mov78452_epce02-20a Page 10
24-FEB-03
Control
systems
A variety of control
systems can be
controlled using
only the air conditioner
remote control
Group Control
One air conditioner remote
control simultaneously controls
up to 16 air conditioners and
1 HRV unit.
Air Conditioner
Up to 16 units
HRV
Air conditioner
remote control
Up to 500m
Air Conditioner
Group control
possible
HRV
Up to 500m
Air conditioner remote control (No.2)
Air conditioner remote control (No.1)
Air Conditioner
Group control
possible
HRV
Up to 500m
Air conditioner remote control
Control via 2 remote controls
page
Air Conditioner
Group control
possible
HRV
Up to 500 m
Air conditioner remote control
HRV remote control
10
mov78452_epce02-20a Page 11
24-FEB-03
Centralised control
systems
By combining the centralised
control systems (available as
accessory) below, the user can
achieve a wide range of
comprehensive centralised
control systems for air
conditioning and ventilation.
DCS302B51
DCS301B51
DST301B51
Schedule timer
One unit can control the operation of up to 128 HRV and air
conditioner units on a weekly schedule.
Can set two ON/OFF operations per day for a period of one week.
page
11
2 units
8 units
1 unit
mov78452_epce02-20a Page 12
24-FEB-03
Control
systems
System
characteristics
INDEPENDENT
OPERATION
SIMULTANEOUS
OPERATION OF
MULTIPLE UNITS
STANDARD SYSTEM
HRV
Indoor unit
HRV
Air conditioner
remote control
Group 1
Indoor
unit
Air conditioner
remote control
Group 1
Indoor
unit
Air conditioner
remote control
HRV
page
12
HRV
remote
control
Main
remote control
Group 2
Indoor
unit
Air conditioner
remote control
Group 2
Air
conditioner
remote
control
Indoor
unit
Air conditioner
remote control
Wiring adapter
for electrical
appendices
HRV
remote
control
HRV
remote control
Main
remote control
Necessary
accessories
Independent operation of
HRV is possible.
HRV
HRV
System construction
HRV
Air
conditioner
remote
control
mov78452_epce02-20a Page 13
24-FEB-03
Image of group
control system
ON/OFF
control
HRV
Indoor
unit
Indoor
unit
HRV LCD
remote
control
Air conditioner
remote control
HRV
Indoor
unit
Indoor
unit
Indoor
unit
Indoor
unit
HRV
Air conditioner
remote control
Indoor
unit
Indoor
unit
HRV
COMBINATION
WITH OTHER
TYPES OF
AIR CONDITIONERS
HRV
Can connect to
multiple HRV units
Air conditioner
remote control
Air conditioner
Air conditioner
remote control
page
13
Combined system
Independent
system
System
characteristics
Necessary
accessories
Unified ON/OFF
control, air
conditioner
remote control.
When necessary,
centralised remote
control, schedule
timer, HRV remote
control, and Sky Air
connection adapter
Unified ON/OFF
control, air
conditioner
remote control.
When necessary,
centralised remote
control, schedule
timer, HRV remote
control, and Sky Air
connection adapter
Simultaneous operation of
HRVs and air conditioners is
possible using the air
conditioner remote control.
Use of the HRV remote
control enables to change
settings or operate HRVs
independently.
Connection adapter
(No-voltage
a-contact signal)
HRV LCD
remote
control
Air conditioner
remote control
Centralised remote
control
System construction
Combined
individual system
Connecting line
can be extended
up to 50m
mov78452_epce02-20a Page 14
24-FEB-03
M
Model
Line-up
VAM150FA7VE
50Hz, 220-240V
60Hz, 220V
Exchange efficiency
90 (%)
VAM150FAVE
Tem
pera
ture
exc
80
han
ge
effic
ienc
y
Ent
halp
ye
xch
ang
e
Ent
halp
ye
xch
ang
ee
ffic
Ultra-High
200
70
effic
ien
cy (h
eati
n
20m
60
g)
ien
cy
(co
olin
g)
VAM250FA7VE
15m
High
50Hz, 220-240V
60Hz, 220V
150
Exchange efficiency
10m
90 (%)
100
VAM250FAVE
Tempe
rature
exchan
ge effic
iency
Enthal
py ex
chang
e effic
iency
(heatin
g)
Enthal
py exch
ange
efficie
ncy (c
ooling)
5m
50
100
Pipe
length
Low
0
50
100
150
200
250
Air flow rate (m3/h)
250
80
70
60
Ultra-High
200
External static pressure (Pa)
150
Pipe
length
High
150
40m
30m
100
50
20m
Low
10m
0
50
100
150
200
250
300
350
Air flow rate (m3/h)
VAM350FA7VE
50Hz, 220-240V
60Hz, 220V
Exchange efficiency
VAM350FAVE
Tem
pera
Enth
300
Ent
halp
y
alpy
exch
a
exc
han
ge
250
ture
exch
nge
ang e
80
effic
ie
effic
ienc
y (h
effic
ienc
y
nc y
eatin
g)
70
30m
60
(coo
ling
)
Ultra-High
200
90 (%)
40m
VAM500FA7VE
50
20m
50Hz, 220-240V
60Hz, 220V
High
150
Exchange efficiency
400
100
90 (%)
10m
VAM500FAVE
150
Pipe
length
50
Low
Temp
eratu
re exch
350
Enth
a
icien
Enth
150
200
250
300
Air flow rate (m3/h)
250
External static pressure (Pa)
100
80
efficie
ncy
hang
e eff
300
0
50
ange
lpy e
xc
alpy
e
xcha
n
ge e
fficie
70
cy (h
eating)
ncy
(co
Ultra-High
200
60
oling
High
200
Pipe
length
50m
150
40m
100
30m
20m
Low
50
10m
0
100
page
14
200
300
400
500
600
700
Air flow rate (m3/h)
mov78452_epce02-20a Page 15
24-FEB-03
VAM650FA5VE
50Hz, 220-240V
60Hz, 220V
Exchange efficiency
550
90 (%)
VAM650FAVE
Tempe
rature
500
Entha
450
Enth
a
exchan
lpy ex
chang
lpy e
xc
400
hang
e
ge effic
e effic
iency
(h
efficie
ncy (c
80
iency
70
eating)
60
oolin
g)
350
VAM800FA5VE
50
Ultra-High
60m
300
High
50m
250
40m
200
30m
150
50Hz, 220-240V
60Hz, 220V
Low
Exchange efficiency
20m
100
90 (%)
VAM800FA(5)VE
Temp
eratu
400
hang
ee
100
fficie
ncy
Enth
alpy
exch
ange
Enth
effic
alpy
ienc
exch
y (hea
ang
ting)
e eff
icien
cy (c
oolin
g)
Ultra-High
500
re exc
10m
50
80
200
300
400
500
600
700
800
900
Air flow rate (m3/h)
70
60
High
300
50
200
100m
VAM1000FA5VE
80m
Low
60m
100
50Hz, 220-240V
60Hz, 220V
40m
Exchange efficiency
90 (%)
20m
0
200
400
600
800
1000
Air flow rate (m3/h)
250
Pipe
length
VAM1000FA5VE
Tempe
rature
exchan
ge effic
iency
Enth
alpy
exch
ang e
effic
iency
(heatin
Enth
g)
alpy
exch
ang e
effic
iency
(coo
ling)
500
VAM1500FA5VE
400
External static pressure (Pa)
Enth
Enth
alpy
60
100m
80m
200
60m
High
40m
Low
20m
0
VAM1500FA5VE
Tem
p
500
70
Exchange efficiency
90 (%)
700
600
80
Ultra-High
300
100
50Hz, 220-240V
60Hz, 220V
200
Pipe
length
400
600
800
1000
1200
3
eratu
alpy
exch
400
200
re ex
exch
a
a ng e
chan
g
ng e
80
e eff
icien
cy
effic
iency
(heatin
g
effic
iency
(c
250
Pipe
length
70
)
60
oolin
g)
50
300
Ultra-High
VAM2000FA5VE
200
High
100
50Hz, 220-240V
60Hz, 220V
Low
Exchange efficiency
90 (%)
0
500
1000
1500
2000
VAM2000FA5VE
2500
Tempe
Entha
500
Enth
alpy
rature
exch
ang e
80
exchan
ge effic
iency
lpy e
xcha
ng
e eff
effic
400
iciency
(h
iency
(coo
70
eating)
60
ling)
Ultra-High
50
300
200
High
100
Low
0
500
1000
1500
2000
2500
page
15
mov78452_epce02-20a Page 16
24-FEB-03
Dimensions
VAM150~500FA7VE
VAM650~1000FA5VE
20
Fresh air
from outdoors
(Outdoor air)
OA
Supply
air to
room SA
EA
Exhaust
air to outdoors
67
150~250
600 or more
A
B
Celling hook
4-14x40 oval hole
Inspection
hole
450
20
RA
Return
air from
room
Damper plate
M
Maintenance cover
J
K
L
Remark:
Be sure to provide the inspection
hole (450x450mm) to inspect
air filters, exchange elements and fans.
DIMENSIONS
VAM150FA7VE
Switch box
VAM250FA7VE
VAM350FA7VE
VAM500FA7VE
VAM650FA5VE
VAM800FA5VE
VAM1000FA5VE
page
16
Air filters
H
145
132
132
84
J
760
89
97
146 200
812
137
912
197
196 250
988
246
263 146
264 157
379 189
mov78452_epce02-20a Page 17
24-FEB-03
VAM1500~2000FA5VE
Switch box
EA
Exhaust air
to outdoors
380
140
Fresh air
from
outdoors
(Outdoor air)
OA
20
325
RA
Return air
from room
A
B
E
1186
Supply air
to room
SA
380
C
95
20
710
383
Celling hook
4-14x40 oval hole
Inspection
hole
450
200~300
600 or more
912
Damper plate
988
DIMENSIONS
VAM1500FA5VE
VAM2000FA5VE
page
17
14.5
Remark:
Be sure to provide the
inspection hole (450x450mm)
to inspect air filters, exchange
elements and fans.
Air filters
Switch box
130
621
254
621
395
350
330
130
16.5
Maintenance cover
(Heat
exchange
element)
mov78452_epce02-20a Page 18
24-FEB-03
Specifications
Models
Temperature exchange efficiency (%)
Enthalpy exchange
efficiency (%)
for heating
for cooling
Power Supply
Sound pressure
level dB(A)
VAM-FA7VE
250
350
150
Heat exchange
mode
Bypass mode
External static
pressure (Pa)
74
74
79
64
64
69
58
58
64
72
72
77
64
64
68
58
58
62
27-28.5
26-27.5
20.5-21.5
27-28.5
26.5-27.5
20.5-21.5
28-29
26-27
21-22
28-29
27-28
21-22
mm
kg
ultra-high
kW
mm
page
18
150
150
110
69
39
20
250
250
155
64
39
20
0.030 x 2
100
650
800
74
74
74
74
74
74
77
77
76
62
63
65
62
63
65
67
66
67
58
58
60
58
58
60
63
63
62
1 ~, 220~240V, 50Hz
32-34
33-34.5
34.5-35.5
36-37
31.5-33
31.5-33
33-34
34.5-36
23.5-26
24.5-26.5
27-28
31-32
32-34
33.5-34.5
34.5-35.5
36-37
31-32.5
32.5-33.5
34-35
34.5-36
24.5-26.5
25.5-27.5
27-28.5
31-33
galvanised steel plate
self-extinguishable urethane foam
285 x 812 x 800
348 x 988 x 852
24
high
low
ultra-high
high
low
Motor Output
Connection Duct Diameter
Unit ambient condition
75
75
80
65
65
70
61
61
67
VAM-FA
Casing
Insulation Material
Dimensions
HxWxD
Weight
Heat Exchange System
Heat Exchange Element Material
Air Filter
Fan
Type
Air Flow
Rate (m3/h)
ultra-high
high
low
ultra-high
high
low
ultra-high
high
low
VE
ultra-high
high
low
ultra-high
high
low
500
150
VAM-FA5VE
1000
1500
2000
75
75
76.5
66
66
68
61
61
63
75
75
78
66
66
68
61
61
64
75
75
78
66
66
70
61
61
66
36-37
35-36
31-32
36-37
35.5-36
31-32
39.5-41.5
38-39
34-36
40.5-41.5
38-39
33.5-36
40-42.5
38-41
35-37
40-42.5
38-41
35-37
Notes: Air flow rate can be changed over to Low mode or High mode.
Sound pressure level is measured at 1.5m below the center of the body.
Sound pressure level is measured in an anechoic chamber.
Sound pressure levels generally become greater than this value depending on the operating conditions, reflected sound, and peripheral noise.
The sound pressure level at the air discharge port is about 8dB higher than the unit's sound level.
Even when the outdoor temperature is below -15C, the system is operable down to -20C with the pre-heater installed at the outdoor air intake side.
mov78452_epce02-20a Page 19
24-FEB-03
Accessories
Air suction/discharge grille (accessory)
Installation of
accessories
Flexible duct
(Accessory)
High efficiency filter
(Accessory)
RA
SA
Round hood
(Field supply)
Branch duct
(Field supply)
Silencer ( Accessory)
SA
Duct
(Field supply)
Thermal insulation material
(Field supply)
EA
OA
List of
accessories
VAM-FA7VE
250
350
Model
Item
150
PC Board Adapter
Controlling device
FXYCP
KRP1B61*
KRP1B96 *2, 3
Notes:
page
19
FXK
KRP1B61
500
650
800
VAM-FA5VE
1000
1500
BRC301B61
DCS302B51
DCS301B51
DST301B51
KRP2A61
KRP50-2
KRP50-2A90 (mounted electric component assembly of HRV)
BRP4A50
FXYFP
FXYSP
FXH
FXYAP/FXA
FXL
KRP1B59*
KRP1B61
KRP1B3
KRP1D98*4
KRP1B93*3
Schedule timer
FXN
KRP1B61
2000
FXM
mov78452_epce02-20a Page 20
24-FEB-03
Silencer
VAM-FA7VE
250
350
Model
Additional function
Item
Silencer
150
reference
nominal pipe (mm)
white
nominal pipe (mm)
Air suction /
Discharge grille
High efficiency filter
Replacement for high efficiency filter
Flexible duct (1m)
Flexible duct (2m)
Duct adapter
reference
nominal pipe (mm)
Direct expansion
reference
coil unit
discharge adapter
K-DGL100A
100
YAFM323F15
YAFF323F15
K-FDS101C
K-FDS102C
K-DGL150A
150
YAFM323F25
YAFM323F35
YAFF323F25
YAFF323F35
K-FDS151C
K-FDS152C
500
Flexible duct
(Noise suppression type)
650
KDDM24A50
200
K-DGL200A
200
YAFM323F50
YAFF323F50
K-FDS201C
K-FDS202C
BHDM50AJVE
KDAJ25K36
800
VAM-FA5VE
1000
1500
KDDM24A100
YAFM323F65
YAFF323F65
BHDM80AJVE
KDAJ25K56
Duct adapter
2000
KDDM24A100X2
250
K-DGL250A
250
YAFM323F100 YAFM323F65X2 YAFM323F100X2
YAFF323F100 YAFF323F65X2 YAFF323F100X2
K-FDS251C
K-FDS252C
YDFA25A1
250
BHDM100AJVE
INDOOR
RA
OUTDOOR
EA
HRV
SA
BRP4A50
Temperature thermostat. (field supply)
(OFF when the temperature is at or more than 5C)
Heater
control kit
(field supply)
OA
Temperature thermostat
(field supply)
(ON when the temperature
is at or below -10C)
page
20
mov78452_epce02-20a Page 21
24-FEB-03
OUTDOOR
INDOOR
RA
EA
HRV
SA
BHDM
OA
Connection with
VRV system
HRV remote
control
Air conditioner
remote control
Notes:
Be sure to interlock HRV and BHDM in the same group by using an air conditioner remote control.
All system operations other than air flow rate switching can be controlled using the air conditioner remote control. To switch the air flow rate,
please use the HRV remote control.
Specifications :
direct expansion coil unit
BHDM-AJVE
50
Capacity index
Power supply
Cooling capacity *1
Heating capacity *2
25
Casing/colour
Dimensions
Air flow rate range
Weight
Piping
connection
Flare
connection
HxWxD
liquid
gas
drain
kW
kW
2.8 (3.0*)
3.2 (3.2*)
mm
m3/h
kg
mm
mm
mm
80
40
1 ~, 220~240V / 220V, 50Hz/60Hz
4.5 (4.8*)
5.0 (5.0*)
galvanised steel plate
300 x 700 x 800
480~780
25
6.4
12.7
VP25 (external diameter 32, internal diameter 25)
R-407C
Refrigerant *3
100
50
5.6 (6.1*)
6.3 (6.3*)
540~930
9.5
15.9
Notes
*1. Nominal cooling capacities are based on:
indoor temperature: 27CDB, 19CWB outdoor temperature: 35CDB equivalent refrigeratn piping: 5m (horizontal)
*2. Nominal heating capacities are based on: indoor temperature: 20CDB outdoor temperature: 7CDB, 6CWB equivalent refrigerant piping: 5m (horizontal)
Cooling and Heating capacities marked with * are in case of connecting HRV unit.
Cooling capacities are based on:
Indoor temperature: 27CDB, 50RH% Outdoor temperature: 35CDB, 60RH% Equivalent ref. piping: 5m (horizontal)
HRV performance :
Temperature exchange efficiency: 74% Enthalpy exchange efficiency: 58%
Heating capacities are based on:
Indoor temperature: 20CDB, 40RH% Outdoor temperature: 7CDB, 70RH% Equivalent ref. piping: 5m (horizontal)
HRV performance :
Temperature exchange efficiency: 74% Enthalpy exchange efficiency: 62%
*3. R-22 compatible models can be manufactured on request
page
21
mov78452_epce02-20a Page 22
24-FEB-03
9
150
9
10
27
YVIEW
145
67
150
200
135
300
245
215
150
5
Y
G
H
4-M8~10
65
800
440
315
135 120
60
50
25
suspension
C
2X65=130
4-screw
bottom plate
57
E
F
service space
1.
2.
3.
4.
DIMENSIONS
A
600
BHDM80AJVE
750
BHDM100AJVE
page
4
300 or more
required installation space
11
BHDM50AJVE
ZVIEW
46
300 or more
XVIEW
45
22
B
4x65=
260
6x65=
390
5.
6.
7.
8.
550
310
700
460
E
2x150=
300
3x150=
450
F
335
485
197
89
137
89
246 263
mov78452_epce02-20a Page 23
24-FEB-03
mov78452_epce02-20a Page 24
24-FEB-03
Zandvoordestraat 300
B-8400 Oostende, Belgium
Internet: http://www.daikineurope.com