stressing is continued to achieve the required jacking force/extension, without exceeding the specified
values by more than 5%. Tendons satisfying the above are locked. Tendons failing to satisfy are pulled out,
reinserted after cleaning blockages, if any, and stressed again.
Piles
21. All pile reinforcement are extended into pile caps as indicated on the drawings.
22. Precast and cast-in-place piles have the contact surfaces with the pile cap scrabbled in accordance with
the specification and are extended 50mm (min) into the pile cap.