Professional Documents
Culture Documents
DIGITAL THERMOSTAT
Use 5 and 6 buttons to display Option 06.The SET icon should be off.
normally should not be modified by the home owner. These options are
Press M button once. The SET icon will be come on. The display now
Press M button again to return to Option 06. The SET icon will now be off.
button
Wire Diagram
TST-EFNC06213SCS00/ TST-EFNNC06223SCS00:
TST-EFNC06213SCS00 / TST-EFND06213SCS01
PROTECTION)
L(R)
L(R)
In the low temperature protection mode, When the thermostat is off , and
Val2
Heating Val
TST-EFNC06223SCS00 / TST-EFND06223SCS01
-CoolHeat and Ventilation
Val1
Cooling Val
Low
Low
TO ADJUST:
Med
Med
Hi
Hi
N(C)
N(C)
-Blue Backlight
-Fahrenheit or Centigrade
-Auto Recovery
off.
Press M button once. The SET icon will be come on. The display now
Heat mode
Cool mode
Room temperature
as required.
Press M button again to return to Option 01. The SET icon will now be
TST-EFND06213SCS01/ TST-EFND06223SCS01:
L(R)
L(R)
Val2
Heating Val
Val1
Cooling Val
Low
Low
Med
Med
Hi
Hi
off.
N(C)
N(C)
off.
Change mode
button
Fan indicator
TO ADJUST:
Enter configuration mode (if not already there).
Power button
Mode button
Not used
Press M button once. The SET icon will be come on. The display now
Specification
Operating difference: 1
Press M button again to return to Option 02. The SET icon will now be
off.
button
S1
OUTDOOR SENSOR
S2
CONNECTION
Fan coil
THERMOSTAT
Display: LCD
Power supply:
temperature sensor. There are various reasons why the home owners
Installation:
Thermostat Location
temperature. The number can range between -5 and +5. Factory default
Basic Operation
To turn the thermostat on, press
or
),
plus or minus 1F, so this adjustment will provide the best accuracy when
TO ADJUST:
Use 5 and 6 buttons to display Option 03.The SET icon should be
off.
Press M button once. The SET icon will be come on. The display now
is displayed, it will be
apart.
Press M button again to return to Option 03. The SET icon will now be
off.
Fan Setting:
Fan speed select: press the fan button to select
Auto. In mode
which will be displayed and acted upon as if it were 72. The effect is that
Select Mode:
partitioning wall.
set to 0.
read 74F. If setpoint is 72, the room will control to an actual value of 70
a positive number selection will make the room temperature lower and
Power ON/OFF
Low
Fan coil
THERMOSTAT
Hi
Med
button
Auto recovery feature means the thermostat will retain the previous
status when power is back. This option can be used to choose whether
).
TO ADJUST
packing box.
off.
Press M button once. The SET icon will come on. The display now
TST-EFND06213SCS01 / TST-EFND06223SCS01:
point is displayed.
Press the MODE button to select the second temperature setting(either
HEAT or COOL)
Error Codes
TST-EFNC06213SCS00 / TST-EFNC06223SCS00:
button
TST-EFND06213SCS01 / TST-EFND06223SCS01:
temperature reaches the set point, valve will close, fan will keep running;
DB means that when temperature reaches the set point, Valve and fan
will close together.
TO ADJUST