You are on page 1of 5

TX output power & Combiner loss (dBm)

Low loss configuration (Non Combine)

Combine Configuration

Standard MP Configuration

MP Power 45.44dBm / 35W ====>

ANCD Non-Combine (-0.95dBm)

===> 44.4dBm / 27.5W

MP Power 45.44dBm / 35W ====>

ANCD Combine (-4.4dBm)

===> 41.0dBm / 12.5W

MP Power 45.44dBm / 35W ====>

ANY (-3.3dBm)

ANCD Combine (-4.4dBm)

===> 37.5dBm / 5.6W

No-Double Ant Solution


No.MP TRX
per sector
1 TRE
2 TRE
3 TRE
4 TRE
5 TRE
6 TRE
7 TRE
8 TRE

No. of
Antenna
1
1
1
1
1
1
1
1

ANCD mode
No-Combining (-0.95dBm)
No-Combining (-0.95dBm)
Combining (-4.4dBm)
Combining (-4.4dBm)
Combining (-4.4dBm)
Combining (-4.4dBm)
Combining (-4.4dBm)
Combining (-4.4dBm)

ANY Mode
Combine (-3.3dBm)
Combine (-3.3dBm)
Combine (-3.3dBm)
Combine (-3.3dBm)

TRE Type
MP Low-loss
MP Low-loss
MP Combine
MP Combine
MP Combine + ANY
MP Combine + ANY
MP Combine + ANY
MP Combine + ANY

Output power at Ant


Connector
44.4dBm / 27.5W
44.4dBm / 27.5W
41.0dBm / 12.5W
41.0dBm / 12.5W
37.5dBm / 5.6W
37.5dBm / 5.6W
37.5dBm / 5.6W
37.5dBm / 5.6W

Remark
Used
Used
Used
Used
Used less
Used less
Used less
Used less

* Remark; used / used less: configuration on north region network


MP Low -loss Configuration

Double Ant Solution


No.MP TRX
per sector
1 TRE
2 TRE
3 TRE
4 TRE
5 TRE
6 TRE
7 TRE
8 TRE

No. of
Antenna
1
1
2
2
2
2
2
2

ANCD mode
No-Combining (-0.95dBm)
No-Combining (-0.95dBm)
No-Combining (-0.95dBm)
No-Combining (-0.95dBm)
Combining (-4.4dBm)
Combining (-4.4dBm)
Combining (-4.4dBm)
Combining (-4.4dBm)

ANY Mode
-

TRE Type
MP Low-loss
MP Low-loss
MP Low-loss (Double Ant)
MP Low-loss (Double Ant)
MP Combine (Double Ant)
MP Combine (Double Ant)
MP Combine (Double Ant)
MP Combine (Double Ant)

Output power at Ant


Connector
44.4dBm / 27.5W
44.4dBm / 27.5W
44.4dBm / 27.5W
44.4dBm / 27.5W
41.0dBm / 12.5W
41.0dBm / 12.5W
41.0dBm / 12.5W
41.0dBm / 12.5W

Remark
Used
Used
Not Used
Not Used
Used
Used
Used
Used

Standard HP configuration

HP Power 47.78dBm / 60W ====>

ANCD Non-Combine (-0.95dBm)

HP Power 47.78dBm / 60W ====>

ANCD Combine (-4.4dBm)

===> 46.54dBm / 47.8W


===> 42.8dBm / 24W

No Double Ant solution


No. HP TRX
per sector
1 TRE
2 TRE
3 TRE
4 TRE

No.of
Antenna
1
1
1
1

ANCD mode
No-Combining (-0.95dBm)
No-Combining (-0.95dBm)
Combining (-4.4dBm)
Combining (-4.4dBm)

ANY Mode
-

TRE Type
HP Low-loss
HP Low-loss
HP Combine
HP Combine

Output power at Ant


Connector
46.54dBm / 45W
46.54dBm / 45W
42.73dBm / 18.7W
42.73dBm / 18.7W

Remark
Used
Used
Used
Used

HP Low loss configuration

Double Ant solution


No. HP TRX
per sector
1 TRE
2 TRE
3 TRE
4 TRE
5 TRE
6 TRE
7 TRE
8 TRE

No.of
Antenna
1
1
2
2
2
2
2
2

ANCD mode
No-Combining (-0.95dBm)
No-Combining (-0.95dBm)
No-Combining (-0.95dBm)
No-Combining (-0.95dBm)
Combining (-4.4dBm)
Combining (-4.4dBm)
Combining (-4.4dBm)
Combining (-4.4dBm)

ANY Mode
-

TRE Type
HP Low-loss
HP Low-loss
HP Low-loss (Double Ant)
HP Low-loss (Double Ant)
HP Combine (Double Ant)
HP Combine (Double Ant)
HP Combine (Double Ant)
HP Combine (Double Ant)

Output power at Ant


Connector
46.54dBm / 45W
46.54dBm / 45W
46.54dBm / 45W
46.54dBm / 45W
42.73dBm / 18.7W
42.73dBm / 18.7W
42.73dBm / 18.7W
42.73dBm / 18.7W

Remark
Used
Used
Used
Used
Not Used (Heat Over)
Not Used (Heat Over)
Not Used (Heat Over)
Not Used (Heat Over)

You might also like