You are on page 1of 4

Chemical fixings

37

Injection mortar FIS V


The high-performance hybrid mortar in the shuttle cartridge.

OVERVIEW
Injection mortar
FIS V 360 S,
styrene free

Static mixer FIS S

Injection mortar
FIS V 950 S,
styrene free

Approvals:
European Technical
Approval Option 7 in
conjunction with Threaded
rods FIS A resp. RG M for
non-cracked concrete.
German approval (DIBt) in
conjunction with injection
anchor sleeve FIS H M
and injection anchor parts
FIS G and FIS E for solid
and hollow bricks (solid
brick also without anchor
sleeve).
German approval (DIBt)
for aerated cement in
conjunction with cone drill
PBB, centering sleeve
PBZ and Threaded rod
FIS G.
German approval (DIBt)
for reinforcement bars.
German approval (DIBt)
for Remedial wall tie VBS
8.
German approval (DIBt)
for Weather facing renovation system FWS.
ICC-Approval for threaded
rods and rebars

For fixing of:


Steel constructions
Railings
Hand-rails
Consoles
Ladders
Machines
Cable trays
Staircases
Gates
Facades
Window elements
High racks
Canopies
Stand-off installations

For load data see page 54


Description
Styrene-free, quick-curing high-performance hybrid mortar
(contains vinyl ester resin and cement).
Resin and cement as well as water and hardener are stored
in two separate chambers and are not mixed and activated
until pushed through the static mixer.
Partially-used cartridges can easily be reused by changing
the static mixer.

Accessories / Recommended loads






For fixing in concrete


For fixing in masonry
For fixing in aerated concrete
For reinforcement bars
Appropriate injection guns

Advantages/Benefits

High-performance hybrid mortar for high loads in almost all


building materials.
Universal fixing system for a broad range of applications on
building sites.
Expansion-free anchoring allows low axial spacings and
edge distances.
Extensive range of accessories for a wide variety of
applications.
Ergonomic injection guns for quick and easy installation.
A variety of approvals cover many applications in nearly all
building material and guarantee maximum safety.
First injection system world-wide with approvals for
concrete, reinforcement bars, solid bricks, perforated bricks
and aircrete.
FIXING PRINCIPLES

In detail: The general principles for installation, the correct drilling procedure and much more on page 303.

STANDARDS

You will find everything that has standards


on page 313 under the keyword approvals.

Chemical fixings

38

Technical DATA
Injection mortar FIS V 360 S,
styrene free

Type

Art.-No.

ID

approvals

Injection mortar FIS V 950 S,


styrene free

contents

languages on the lable

shelf life

qty. per box

months

pcs.

18

D, GB, F, NL, I, E, P, JP, PRC

18

10

DIBt ETA

FIS V 360 S

94405

FIS V 950 S

17101

FIS S

61223

1 cartridge 360 ml +
2 static mixer
1 cartridge 950 ml +
2 static mixer
10 static mixer FIS V 360 S

FIS V 360 S HWK small

FIS V 360 S HWK big

Type

Art.-No.

ID

contents

languages on the lable

FIS V 360 S HWK big

96554

FIS V 360 S HWK small

92430

pcs.

20 x FIS V 360 S cartridges + 360 ml/560 g,


40 x static mixers
10 x FIS V 360 S cartridges + 360 ml/560 g,
20 x static mixers

D, GB, F, NL,

D, GB, F, NL,

CURING TIME
Gelling and curing time of fischer FIS V
Cartridge temperature
(mortar)

+ 5C +10C
+ 10C + 20C
+ 20C + 30C
+ 30C + 40C

Gelling time

13 min.
5 min.
4 min.
2 min.

Temperature at
anchoring base
- 5C 0C
0C +5C
+ 5C + 10C
+ 10C + 20C
+ 20C + 30C
+ 30C + 40C

qty. per box

Curing time
24 hrs.
3 hrs.
90 min.
60 min.
45 min.
35 min.

The above times apply from the moment of contact between resin and hardener in the static mixer.
For installation, the cartridge temperature must be at least +5C. For longer installation times, i.e. when interruptions occur in work, the mixer should be replaced.

Chemical fixings

54

Injection technique for concrete


Technical DATA
Compressed-air cleaning gun ABP

Cleaning brush for concrete

Type

Art.-No.

ID

for thread

qty. per box

78177
78178
78179
78180
78181
78182
78183
78184
59456

BS 8
BS 10
BS 12
BS 14
BS 18
BS 24
BS 28
BS 35
ABP

7
4
1
7
4
1
8
5
8

pcs.

M6
M8
M 10
M 12
M 16
M 20
M 24
M 30
-

1
1
1
1
1
1
1
1
1

LOADS - Injection mortar FIS V, FIS VS and FIS VW


Mean ultimate loads, design resistant and recommended loads for single anchors of fischer Injection system FIS V and
FIS VS, FIS VW used with fischer threaded rods with large axial spacing and edge distance.
Anchor size
h01 =
h02 =
h03 =

Effektive anchorage depth =


Drill hole depth
Drill hole diameter

hef1
hef2
hef3
d0

Mean ultimate loads Nu and Vu [kN]

M6

M8

M 10

Non-cracked concrete
M 12
M 16

M 20

M 24

M30

50
60
75
8

65
80
95
10

80
90
110
12

95
110
120
14

160
170
210
24

190
240
285
28

240
280
340
35

[mm]
[mm]
[mm]
[mm]

A4
14.1*
14.1*
14.1*
8.4*

gvz
19.0*
19.0*
19.0*
11.4*

A4
25.6*
25.6*
25.6*
15.4*

gvz
30.2*
30.2*
30.2*
18.1*

A4
40.6*
40.6*
40.6*
24.4*

gvz
43.8*
43.8*
43.8*
26.3*

A4
58.4
59.0*
59.0*
35.4*

gvz
A4
gvz
81.6* 93.2 127.4
81.6* 104.4 127.4*
81.6* 109.9* 127.4*
49.0* 65.9* 76.4*

gvz
4.7
5.7
7.1
4.2

A4
4.7
5.7
7.1
4.5

gvz
8.2
10.1
11.9
7.6

A4
8.2
10.1
11.9
8.2

gvz
12.6
14.1
17.3
12.1

A4
12.6
14.1
17.3
13.0

gvz
17.9
20.7
22.6
17.5

A4
17.9
20.7
22.6
18.9

gvz
31.4
35.2
42.7
32.6

gvz

A4

gvz

A4

gvz

A4

gvz

A4

gvz

A4

gvz

A4

gvz

A4

gvz

A4

3.4
4.1
5.1
3.0

3.4
4.1
5.1
3.2

5.9
7.2
8.5
5.4

5.9
7.2
8.5
5.9

9.0
10.1
12.4
8.6

9.0
10.1
12.4
9.3

12.8
14.8
16.1
12.5

12.8
14.8
16.1
13.5

22.4
25.1
30.5
23.3

22.4
25.1
30.5
25.2

28.7
30.5
37.7
36.4

28.7
30.5
37.7
39.3

40.9
51.7
61.4
52.4

40.9
51.7
61.4
56.6

48.4
56.6
68.6
83.4

48.4
56.6
68.6
89.9

gvz
Mrec [Nm]
4.5
Component dimensions, minimum axial spacings and edge distances

A4
4.9

gvz
11.4

A4
11.9

gvz
22.3

A4
23.8

gvz
38.9

A4
42.1

gvz
98.9

A4
gvz
A4
gvz
A4
gvz
A4
106.7 193.1 207.9 333.1 359.4 668.0 720.7

Tensile

Nu

Shear

90

Vu

gvz
[kN] hef1 10.5*
[kN] hef2 10.5*
[kN] hef3 10.5*
[kN]
6.3*

125
140
170
18

Design resistant loads NRd and VRd [kN]

Tensile

NRd

Shear

90

VRd

[kN] hef1
[kN] hef2
[kN] hef3
[kN]

Recommended loads Nrec and Vrec [kN]

Tensile

Nrec

Shear

90

Vrec

[kN] hef1
[kN] hef2
[kN] hef3
[kN]

Recommended bending moment Mrec [Nm]

Min. axial spacing 1)


Min. edge distance 1)
Min. structural component thickness
Required torque

smin
cmin
hmin1
hmin2
hmin3
T inst

[mm]
[mm]
[mm]
[mm]
[mm]
[Nm]

40
40
100
100
115
5

40
40
100
110
125
10

45
45
110
120
140
20

55
55
125
140
150
40

A4
31.4
35.2
42.7
35.3

65
65
165
180
210
60

A4
127.4
135.4
167.2
102.9*

gvz
176.9
183.6*
183.6*
110.1*

A4
176.9
223.5
247.1*
148.3*

A4
40.2
42.7
52.8
55.0

gvz
57.3
72.4
85.9
73.4

A4
57.3
72.4
85.9
79.2

gvz
40.2
42.7
52.8
51.0

85
85
210
220
260
120

105
105
250
300
345
150

gvz
248.1
289.5
291.7*
175.0*

A4
248.1
289.5
351.5
235.6*

gvz
A4
67.8 67.8
79.2 79.2
96.1 96.1
116.7 125.9

140
140
310
350
410
300

Steel failure decisive.


For minimum axial spacing and minimum edge distance the above described loads have to be reduced (see fischer Technical Handbook or design software CC-Compufix)!
Values given above are valid under the following assumptions: - Sufficient mechanical cleaning of the drill hole using stainless steel brushes.

- Dry concrete, temperature range 50C long term temperature and 80C short term temperature.
All values apply for concrete C 20/25 without edge or spacing influence.
Design resistant loads: material safety factor M is included. Material safety factor M depends on the type of anchor.
Recommended loads: material safety factor M and safety factor for load L = 1.4 are included.

1)

The condition of application differ from those given in the European Technical Approval (ETA). For further detailed information about the ETA please contact the fischer technical service department.
RG M threaded rods can be used as an alternative. Please refer to page 64 for suitable threaded rods.
Higher loads are available using Premium Cleaning methods. Please contact Technical Department for details on 01491 827920.

Technical Data Sheet


fischer Injection mortar FIS V
FIS V 360 S, FIS V 950 S
Order numbers 94404, 94405, 68435, 17101

Product description:

High performance hybrid mortar in shuttle cartridge, styrene free,


colour: grey

Product data

Testing method Results

Stability

UV-resistance (sunlight)
Temperature resistance
Water resistancy
Water absorption
Cleaning agents
Long-term behaviour
(Freezing and thawing resistance)

EOTA part 5

Resistant
120C
Resistant
After 14 days: 0.8%
1% tenside solution: no
effects
Approved suitability for
outside applications

Physical properties

Flexural strength
Compressive strength
Tensile strength
Elongation at break
Elastic modulus
Shrinkage
Hardness Shore A
Thermal conductivity
Specific contact resistance
pH-value
Density

According to
DIN EN 196-1
According to
DIN EN 196-1
ISO 527
ISO 527
ISO 527
ISO 868
DIN 52612
IEC 60093

After 45 min: 15 N/mm2


After 45 min: 60 N/mm2
After 24 hours: 10 MPa
After 24 hours: 0.47%
After 24 hours: 4.3 GPa
< 0.8%
After 45 min: 91
0.65 W/mK
21.9 17.1 x 109cm
After 24 hours: > 12 (22C)
1.70 0.1 g/cm3

Workability features

Viscosity (20C)
Open time (20C)
Curing time (20C)
Shelf life

TDS FIS V EN 0/2006-03-02

Brookfield (Sp.7) 120 160 Pas


10 U/min
5 min
60 min
18 months

page 1/1