SPLIT-TYPE AIR CONDITIONERS Full Product Line Catalogue 2015

NOTICE

Do not install indoor units in areas (e.g., mobile phone base stations) where the emission of VOCs such as phthalate
compounds and formaldehyde is known to be high as this may result in a chemical reaction.
When installing or relocating or servicing the air conditioners, use only the specified refrigerant (R410A) to charge the
refrigerant lines.
Do not mix it with any other refrigerant and do not allow air to remain in the lines.
If air is mixed with the refrigerant, then it can be the cause of abnormal high pressure in the refrigerant lines, and may result
in an explosion and other hazards.
The use of any refrigerant other than that specified for the system will cause mechanical failure, system malfunction or unit
breakdown. In the worst case, this could lead to a serious impediment to securing product safety.

Eco Changes is the Mitsubishi Electric Groups environmental statement,


and expresses the Groups stance on environmental management.
Through a wide range of businesses, we are helping contribute to the
realization of a sustainable society.

Wrap Yourself in Comfort and Quiet


Eco-conscious Technologies from Japan

Full Product Line Catalogue

2015

For luxury mansion and condominium,


Maximize the comfortability with a single outdoor unit,
Mitsubishi Electric Inverter Multi split Systems

Space Savings

Economical Operation

Silent Control

Flexible Choice

The Mitsubishi Electric Inverter Multi split System is designed


to allow several indoor units to be connected to a single
outdoor unit. This enhances exterior aesthetics by reducing
the number of outdoor units necessary, while also providing
you with an easy and economical way of adding indoor units
at any time.

We are able to offer industry-leading levels of energy-efficient


operation for both heating and cooling with the latest innovative inverter technologies. Save energy and money with the
Mitsubishi Electric Inverter Multi split System.

Comfort with less noise, based on smooth operation and


innovative features such as automatic selection of low-noise
mode when operation load is low. Choose a wall-mounted
model to create a silent and comfortable space where noise
levels are kept low so that soothing peace and quiet can be
enjoyed.

Offering the ability to select up to 6 indoor units for a single


outdoor unit, Mitsubishi Electric Inverter Multi split Systems
satisfy diversified needs. With the cooling capacities of
outdoor units ranging from 5.0 to 12.0kW and a line up of
different models to suit specific applications, you will not be
hard pressed to find a better match for your building dimensions and comfort requirements.

Types of Air Conditioning Systems and


Suitable Choice for Your Home
Enhance room comfort with the air conditioner that best matches the interior.
For reliable operation and design, Mitsubishi Electric is the logical choice.

Single Split
Suitable for
Small residences like studio apartments
Homes with floor area of 20-50m2
Installing additional units if required

TABLE OF CONTENTS

INVERTER MULTI SPLIT


LINE-UP

Inverter Multi Split (5.0~12.0kW)

CITY MULTI (12.5~25.0kW)

Suitable for
Small to medium-sized residences
(condominiums or leased apartments)
Homes with floor area of 50-100m2
Homes with limited space for outdoor unit installation
Increasing usable space at homes (for developers)
Users who prefer to keep neat appearance with ceiling-concealed
model
Wide variety of indoor unit combination

Suitable for
Large-scale residences (condominiums or leased apartments)
Homes with floor area of 80m2 or more
Entrance hall or penthouse
Using a centralized control system as integrated control of air conditioning, lighting, security system and other electric appliances
More freedom in air conditioning design due to less piping length restrictions
Increasing usable space in homes (for developers)
Users who prefer to keep neat appearance with ceiling-concealed
model
Wide variety of indoor unit combination

INVERTER TECHNOLOGIES

7- 8

FUNCTIONS

9-14

MXY SERIES (Cooling Only)

15-24

MXZ SERIES (Heat Pump)

25-33

EXTERNAL DIMEMSIONS

34-39

PIPING INSTALLATIONS

40-41

CITY MULTI
CITY MULTI S SERIES

43-46

INDOOR UNIT LINE-UP

47-48

SYSTEM CONTROL

49-50

Please refer to page 50 for centralized control.

INVERTER
MULTI SPLIT

LINE-UP
INVERTER Models (Cooling Only)

MXY SERIES

5.0kW

7.5kW

7.5kW

9.2kW

Up to 2 indoor units
MXY-2E20VA

Up to 3 indoor units
MXY-3A28VA

Up to 4 indoor units
MXY-4A28VA

Up to 4 indoor units
MXY-4A38VA

Capacity Class

Model Name

SERIES
INVERTER Models (Heat Pump)

MXZ SERIES
Capacity Class

5.2kW

6.8kW

7.1kW

8.0kW

10.0kW

12.0kW

Up to 2 indoor units
MXZ-2C52VA

Up to 3 indoor units
MXZ-3C68VA

Up to 4 indoor units
MXZ-4C71VA

Up to 4 indoor units
MXZ-4C80VA

Up to 5 indoor units
MXZ-5C100VA

Up to 6 indoor units
MXZ-6C120VA

5.0kW

6.0kW

7.1kW

Model Name

Indoor Unit for MXY and MXZ


Model Name

Capacity Class

2.5kW

3.5kW

MSY-E Series
MSZ-E Series

Wallmounted
MSY-G Series
MSZ-G Series

MLZ Series

1-way
cassette

PLA Series

4-way
cassette

SEZ Series

Cellingconcealed

INVERTER TECHNOLOGIES
Mitsubishi Electric inverters ensure superior performance including the optimum control of operation frequency. As a result,
optimum power is applied in all heating/cooling ranges and maximum comfort is achieved while consuming minimal energy.
Fast, comfortable operation and low running cost Thats the Mitsubishi Electric promise.

MORE ADVANTAGES WITH MITSUBISHI ELECTRIC


PAM (Pulse Amplitude Modulation)

Joint Lap DC Motor


Mitsubishi Electric has developed a unique motor, called the
Poki-Poki Motor in Japan, which is manufactured using a joint
lapping technique. This innovative motor operates based on a
high-density, high-magnetic force, leading to extremely high efficiency and reliability.

PAM is a technology that controls the current waveform so that it


resembles the supply voltage wave, thereby reducing loss and realising more efficient use of electricity. Using PAM control, 98% of the
input power supply is used effectively.
With PAM control

Without PAM control


Supply
voltage

INVERTERS HOW THEY WORK

Time

Current

Inverters electronically control the electrical voltage, current and frequency of electrical devices such as the compressor motor in an air conditioner.
They receive information from sensors monitoring operating conditions, and adjust the revolution speed of the compressor, which directly
regulates air conditioner output. Optimum control of operation frequency results in eliminating the consumption of excessive electricity and
providing the most comfortable room environment.

Time

PAM adjusts the form of the current wave so that it becomes close to that of the supply
voltage wave. High harmonics are reduced and 98% of the electricity is utilized.

Merits of PAM Control

Reluctance DC Rotary Compressor


Powerful neodymium magnets are used in the rotor of the reluctance DC compressor motor. More efficient operation is realised by
strong magnetic and reluctance torques produced by the magnets.

ECONOMIC OPERATION
Impressively low operating cost is a key advantage of inverter air conditioners. Weve combined advanced inverter technologies with cutting-edge
electronics and mechanical technologies to achieve a synergistic effect that enables improvements in heating/cooling performance efficiency.
Better performance and lower energy consumption are the result.

Neodymium
magnets

DC compressor
motor (rotor)

Significant energy savings


Remarkable reduction in power
loss saves electricity

Power increased
Efficient voltage increase
realises increased power

PAM
Conventional
inverter
Limited power
Insufficient power
when needed

Limited energy savings


Electricity is wasted

Power Receiver and Twin LEV Control


Mitsubishi Electric has developed a power receiver and twin linear
expansion valves (LEVs) circuit that optimise compressor performance. This technology ensures optimum control in response to operating waveform and outdoor temperature. Operating efficiency has
been enhanced by tailoring the system to the characteristics of R410A
refrigerant.

TRUE COMFORT
Simple comparison of air conditioner operation control with and without inverter

Magnetic torque

Inverter Operation Image (cooling mode)

Cooling capacity (W)

Temperature (C)

Reluctance torque

Rated capacity

Setting temperature

Indoor temperature

Point 2
Measured capacity

Compressor

Power
receiver

Point 1
When room temperature is higher than the
setting, capacity rises quickly, adjusting the
temperature to the original setting.

Heat
exchanger

Heat
exchanger

LEV1

LEV2

Rare Earth Magnet Rotor (Compressor)


An innovative motor with a rare earth magnet rotor is equipped in the
compressor to ensure excellent efficiency. The rare earth magnet
has a residual magnetic flux density threefold that of the previously
used ferrite magnet.

When room temperature reaches the desired


setting, capacity eases in order to maintain
the set temperature level.

Grooved Piping
High-performance grooved piping is used in heat exchangers to increase the heat exchange area.
Grooved piping

Operation time (min)

Rare earth magnet


(for MSZ-EF)

Pipe image
Cross-sectional view

Point 1

Quick & Powerful

Increasing the compressor motor speed by controlling the operation


frequency ensures powerful output at start-up, brings the room
temperature to the comfort zone faster than units not equipped with
an inverter. Hot rooms are cooled, and cold rooms are heated faster
and more efficiently.

Point 2

Room Temperature Maintained

The compressor motor operating frequency and the change of room


temperature are monitored to calculate the most efficient waveform
to maintain the room temperature in the comfort zone. This eliminates the large temperature swings common to non-inverter systems, and guarantees a pleasant, comfortable environment.

DC Fan Motor
A highly efficient DC motor drives the fan of the outdoor unit.
Efficiency is much higher than an equivalent AC motor.

FUNCTIONS (1)

SYSTEM CONTROL
Versatile system controls can be realised using optional parts, relay circuits, control panels, etc.

AIRSYSTEM
DISTRIBUTION
MAJOR
CONTROL

ENERGY-SAVING
Econo Cool Energy-Saving Feature
Econo Cool is an intelligent temperature control feature that adjusts
the amount of air directed towards the body based on the air-outlet
temperature. The setting temperature can be raised by as much as
2C without any loss in comfort, thereby realising a 20% gain in
energy efficiency. (Function only available during manual cooling operation.)
Ambient temperature

Conventional
35C

Horizontal Vane

Econo Cool Mode

A comfortable room environment is maintained even when setting the


temperature 2C higher than the conventional cooling mode.
Econo Cool on

Conventional cooling mode

25C

27C

Perceived temperature

30C

29.3C

The airUnit
outlet vane swings up and down so that the
airflow
is spread
Indoor
M series
Indoor
Unit
evenly throughout
the room.
Outdoor
Unit

In the case of rooms with


high &
ceilings,
outlet-air
volume can be
S series
P series the
Indoor
Unit
increased to ensure that air is
circulated
all the way to the floor.
MXZ
Series Outdoor

MXZ Series Outdoor

Vertical Vane

Low Ceiling Mode


MAC397IF-E

If the room has a low ceiling, the airflow volume can be reduced for
less draft.

The air outlet fin swings from side to side so that theIndoor
airflow
reaches
unit
every part ofControl
the room.
PAR-30MAA
PAR-21MAA Control

Econo Cool
35C

Set temperature

High Ceiling Mode

System Examples

Outdoor unit

PAR-30MAA
PAR-21MAA

PAR-30MAA
PAR-21MAA

Auto Fan Speed Mode

Temperature distribution (C)


14

16

18

20

22

24

26

28

The airflow speed mode adjusts the fan speed of the indoor unit
Standard equipment
automatically
according
to thewith
present
roomcontrollers)
conditions.
(for indoor
units compatible
wired remote

Wired remote controller can be connected to


indoor unit

Details

Wide and Long Airflow

MAC-397IF-E (Interface)

ATTRACTIVE
Pure White

of the room.

PAR-21MAA (Wired remote controller)

Auto Vane

Pure white is adopted for the unit colour; white expressing the
essence of cleanliness and easily matching virtually all interior dcor.

PAR-30MAA (Wired remote controller)

PAR-30MAA
(Wired remote
controller) for large spaces, helping to ensure that air is well circulated and reaches every corner
Major
Parts
Required
The Optional
wide and
long
airflow function
is especially
beneficial
PAR-21MAA (Wired remote controller)

The vane closes automatically when the air conditioner is not


running, concealing the air outlet and creating a flat surface that is
aesthetically appealing.

Indoor unit

Indoor unit

CONVENIENCE
MAC-397IF-E

System Group Control

On/Off Operation Timer

Outdoor unit

Outdoor unit

MAC-397IF-E

PAR-30MAA
PAR-21MAA

PAR-30MAA
PAR-21MAA

Use the remote controller to set the times of turning the air conditioner On/Off.

AIR QUALITY
Catechin Filter

Fresh-air Intake
Indoor air quality is enhanced by the direct intake of fresh exterior air.

Anti-allergy Enzyme Filter


The anti-allergy enzyme filter works to trap allergens such as molds
and bacteria and decompose them using enzymes retained in the
filter.

Catechin is a bioflavonoid by-product of green tea with both antiviral


and antioxidant qualities. It also has an excellent deodorising effect,
which is why Mitsubishi Electric uses the compound in its air conditioner filters. In addition to improving air quality, it prevents the
spreading of bacteria and viruses throughout the room. Easily removed for cleaning and maintenance, when the filter is washed regularly the deodorising action is rated to last more than 10 years.

High-efficiency Filter
This high-performance filter has a much finer mesh compared to standard filters, and is capable of capturing minute particulates floating in
the air that were not previously caught.
Nano
Platinum

Nano Platinum Filter

The filter has a large capture area and incorporates nanometre-sized


platinum-ceramic particles that work to eliminate bacteria and deodourise the circulating air.

Details

Long-life Filter
A special process for the entrapment surface improves the filtering
effect, making the maintenance cycle longer than that of units
equipped with conventional filters.

Filter Check Signal


Air conditioner operating time is monitored, and the user is notified
when filter maintenance is necessary.
Electrostatic
Anti-allergy

Electrostatic Anti-allergy Enzyme Filter

This function features both the Air Cleaning Filter and Anti-allergy
Enzyme Filter.

One remote controller can control plural air conditioners with the same settings simultaneously.
One remote controller can control up to 16 refrigerant systems. (When connected to a MXZ unit, MAC-397IF-E is counted as one system.)

Up to two remote controller can be connected.


i save Mode/Smart
Set

MAC-397IF-E (Interface)
i save is a simplified setting
function that recalls the preferred (preset) temperature by pressing a single button on the remote controller.
PAR-30MAA (Wired remote controller)
PAR-21MAA
(Wired
remote controller)
Smart Set : Press the same button
twice
in repetition
to immediately return to the previous temperature setting.
Using this function contributes to comfortable waste-free operation, realising the most suitable air conditioning settings and saving on power
consumption when, for example, leaving the room or going to bed.
Outdoor
Outdoor

Major Optional Parts Required

Outdoor unit

unit

Low-temperature Cooling

(AG-150A etc)
performance even when the outside temperature isPAC-SC50KA
low.

Details

Indoor unit

Auto Restart

City Multi
indoor unit

MELANS
Intelligent
fan speed control in the outdoor unit ensures
optimum
M-NET
Connections
system controller
MAC-399IF-E

ME remote controller
(PAR-F27MEA)

unit

Indoor unit

Indoor unit

PAC-SC50KUA
Power supply
kit

Indoor unit
PAR-30MAA
PAR-21MAA

City Multi
indoor unit

PAR-30MAA
PAR-21MAA
MAC-399IF-E

Indoor unit
PAR-30MAA
PAR-21MAA

PAR-30MAA
PAR-21MAA

Especially useful at the time of power outages, the unit turns back on
MELANS
automatically when
power is restored.
system controller
(AG-150A etc)

Power supply
unit

PAC-SC50KA
Power supply
unit

MELANS
system controller
(AG-150A etc)

M-NET adapter
PAC-SF81MA-E

Low-noise Operation (Outdoor Unit)


Ampere Limit Group
Adjustment
of air conditioners can be controlled by MELANS system controller (M-NET).

Dipswitch settings can be used to adjust the maximum electrical


MAC-399IF-E (M-NET Interface)
current
for Parts
operation.
is highly
recommended for
MELANS System
controller
Major
Optional
RequiredThis function
PAC-SC50KUA (power supply unit)
managing energy costs.

System operation can be adjusted to prioritise less noise from the


PAC-SF81MA-E (M-NET converter)
outdoor unit over air conditioning
performance.
MELANS
System controller
PAC-SC50KUA (power supply unit)

*Maximum capacity is lowered with the use of this function.

MAJOR OPTIONAL PARTS


Operation Lock

Auto Changeover

M-NET
Interfacespecific use applications, cooling or heating
To
accommodate
Interface to connect with M-NET con-

M-NET interface

operation
can be specified when setting the control board of the
trollers.
outdoor unit. A convenient option when a system needs to be
configured for exclusive cooling or heating service.

Air
Guide
TheDischarge
air conditioner
automatically switches between heating and coolChanges the direction of air being
ing modes
to maintain
theunit.
desired temperature.
exhausted
from
the outdoor

10

FUNCTIONS
FUNCTIONS (2)

SYSTEM CONTROL
Versatile system controls can be realised using optional parts, relay circuits, control panels, etc.

Built-in Weekly Timer Function

MAJOR SYSTEM CONTROL

Easily sets desired temperatures and operation start/stop times to match lifestyle patterns. Reduce wasted energy consumption by using the timer
to prevent forgetting to turn off the unit and eliminate temperature setting adjustments.
Example Operation Pattern (Winter/Heating mode)
Mon.

Tues.

Wed.

Thurs.

Fri.

Sat.

Sun.

ON 20C

ON 20C

ON 20C

ON 20C

ON 20C

ON 20C

ON 20C

ON 18C

ON 18C

System Examples

Indoor Unit

M series Indoor Unit

S series & P series Indoor Unit

Outdoor Unit

MXZ Series Outdoor

MXZ Series Outdoor

Automatically changes to high-power operation at wake-up time


MAC397IF-E

OFF

OFF

OFF

OFF

OFF

Midday is warmer,
so the temperature is set lower

Automatically turned off during work hours

ON 20C

ON 20C

ON 20C

ON 20C

ON 20C

(during sleeping hours)

ON 18C

ON 18C

ON 18C

ON 18C

ON 20C

ON 18C

ON 18C

PAR-30MAA Control
PAR-21MAA Control

PAR-30MAA
PAR-21MAA

PAR-30MAA
PAR-21MAA

Details

Wired remote controller can be connected to


indoor unit

Standard equipment
(for indoor units compatible with wired remote controllers)

Major Optional Parts Required

MAC-397IF-E (Interface)
PAR-30MAA (Wired remote controller)
PAR-21MAA (Wired remote controller)

PAR-30MAA (Wired remote controller)


PAR-21MAA (Wired remote controller)

ON 18C

Automatically lowers temperature at bedtime for energy-saving operation at night

Settings

Outdoor unit

ON 20C

Automatically raises temperature setting to


match time when outside-air temperature is low

Automatically turns on, synchronized with arrival at home

Indoor unit

Pattern Settings: Input up to four settings for each day


Settings: Start/Stop operation Temperature setting The operation mode cannot be set.

Indoor unit

Indoor unit

MAC-397IF-E

Cleaning-free Pipe Reuse


The application of pipe reuse technology such as Mitsubishi Electrics original hard alkyl benzene oil makes it possible to reuse the same piping,
thereby allowing cleaning-free renewal of air conditioning systems that use R22 refrigerant.

Wiring/Piping Correction Function*


The push of a single button is all that is required to confirm that
piping and wiring are properly connected. Corrections are made automatically if a wiring error is detected, eliminating the need for complicated wiring confirmation work when expanding the number of
rooms served.

Wiring
confirmation
is time
consuming.

The outdoor unit


matches
pipes and wiring.

System Group Control


Outdoor unit

PAR-30MAA
PAR-21MAA

PAR-30MAA
PAR-21MAA

Details

One remote controller can control plural air conditioners with the same settings simultaneously.
One remote controller can control up to 16 refrigerant systems. (When connected to a MXZ unit, MAC-397IF-E is counted as one system.)
Up to two remote controller can be connected.

Major Optional Parts Required

MAC-397IF-E (Interface)
PAR-30MAA (Wired remote controller)
PAR-21MAA (Wired remote controller)

Outdoor unit

* This function cannot be used when the outdoor temperature is below 0C.
The correction process requires 1020 minutes, and only works when the unit is set
to the Cooling mode.

Indoor unit

Outdoor
unit

Outdoor
unit

Indoor unit

Indoor unit

City Multi
indoor unit

M-NET Connections

Drain Pump

Flare Connection

A built-in drain pump enables drain piping to be raised.

Outdoor unit

MAC-397IF-E

ME remote controller
(PAR-F27MEA)

Flare connection to cooling pipe work is possible.

MAINTENANCE

MAC-399IF-E

MELANS
system controller
(AG-150A etc)

PAC-SC50KUA
Power supply
kit

PAR-30MAA
PAR-21MAA

Indoor unit
PAR-30MAA
PAR-21MAA

City Multi
indoor unit

Indoor unit
PAR-30MAA
PAR-21MAA

PAR-30MAA
PAR-21MAA

MAC-399IF-E

MELANS
system controller
(AG-150A etc)

PAC-SC50KA
Power supply
unit

PAC-SC50KA
Power supply
unit

Details

Group of air conditioners can be controlled by MELANS system controller (M-NET).

Major Optional Parts Required

MAC-399IF-E (M-NET Interface)


MELANS System controller
PAC-SC50KUA (power supply unit)

MELANS
system controller
(AG-150A etc)

M-NET adapter
PAC-SF81MA-E

PAC-SF81MA-E (M-NET converter)


MELANS System controller
PAC-SC50KUA (power supply unit)

Easy Clean

MAJOR OPTIONAL PARTS

The cover panel can be quickly removed for washing and the airflow vents can be opened without any special tools, making it easy to clean the
inside of the air conditioner in minutes. Periodic cleaning of the air conditioner is recommended to maintain optimum operating efficiency and
energy savings.

Self-Diagnostic Function (Check Code Display)


Check codes are displayed on the remote controller or the operation
indicator to inform the user of malfunctions detected.

11

Failure Recall Function

Air Discharge Guide

M-NET Interface

Interface to connect with M-NET controllers.

M-NET interface

Changes the direction of air being


exhausted from the outdoor unit.

Operation failures are recorded, allowing confirmation when needed.

12

FUNCTION LIST

Category
Category

Indoor Unit

Icon

Combination

Outdoor Unit
DCunit
Inverter
Indoor
MSZ-FD20/35/50VA(S)
Joint Lap DC Motor
Reluctance
DC Rotary
Compressor
MUZ
MXZ MXZ
MXZ MXZ MXZ MXZ
Outdoor unit
Rare Earth-FD
Magnet
-2CRotor
-3C(Compressor)
-4C -5C -6C -8B
Technology
DC Fan Motor
DC Inverter
Technology
PAM (Pulse Amplitude Modulation)
Joint Lap DC Motor
Power Receiver and Twin LEV Control
Grooved
Magnetic Flux Vector Sine Wave
Drive Piping
Energy Saving
Econo Cool Energy-saving Feature
Reluctance DC Rotary Compressor
80
Pure White
Attractive
Highly Efficient DC Scroll Compressor
Auto Vane
Fresh-air Intake
Rare Earth Magnet Rotor(Compressor)
Anti-allergy Enzyme Filter
DC Fan Motor
Electrostatic Anti-allergy Enzyme Filter
Vector-Wave Eco Inverter High-efficiency Filter
Air Quality
Catechin Filter
PAM(Pulse Amplitude Modulation)
Nano Platinum Filter
Power Receiver and Twin LEV Control
Long-life Filter
Grooved Piping
Filter Check Signal
Energy
Vane
Felt Temperature Control (i-seeHorizontal
Sensor)
Saving
Vertical Mode
AREA Temperature Monitor
High Ceiling Mode
AirEcono
Distribution
Cool Energy-saving Low
Feature
Ceiling Mode
Functions
Auto Fan Speed Mode
'I-Feel' Control
Wide and Long Airflow
Demand Function
Opt
On/Off Operation Timer
Attractive Pure White
VA
VA
VA
VA
VA Set
VA / Smart
VA
"i save" Mode
Auto Restart
Auto Vane
Low-noise Operation
Air QualityConvenience
Plasma Duo
Ampere Limit Adjustment
Air Cleaning Filter
Operation Lock
Fresh-air Intake
Built-in Weekly Timer Function
Anti-allergy Enzyme Filter Cleaning-free Pipe Reuse
Wiring/Piping Correction Function
Installation
Electrostatic Anti-allergy Enzyme Filter
Drain Pump
High-efficiency Filter
Flare Connection
Easy Clean
Catechin Filter
Maintenance
Self-Diagonosis Function (Check Code Display)
Nano Platinum Filter
Failure Recall Function

MSY-EF (10/13/18)

MXY-2E

MXY-3A

M SERIES

MXY-4A

MSY-GE (10/13/18/24/26)
MXY-2E

MSZ-EF22/25/35/42/50VE(W)(B)(S)

MXY-3A

MLZ-KA (25/35/50)

MXY-4A

MXY-2E

MSZ-GE22/25/35/42/50/60/71VA

MXY-3A

PLA-RP (50/60/71)
MXY-4A

MSZ-SF15/20VA

4A38
4A38
4A38
MUZ MXZ MXZ MXZ MXZ MXZ
MXZ MUZ MXZ MXZ MXZ MXZ MXZ
MXZ MXZ MXZ MXZ MXZ MXZ MXZ
-EF -2C -3C -4C -5C -6C -8B -GE -2C -3C -4C -5C -6C -8B -2C -3C -4C -5C -6C -8B

80

VAW

VAW

Opt

80

VAW

Opt

Opt 10-18
Opt 24/26

Opt

Opt

Opt

10-18

10-18
24/26

10-18
24/26

Opt

Opt

Opt

24/26

24/26

24/26

24/26

*2

*2

24/26

24/26

*2

MUZ MUH MU MUH MUH MUH MU


-HC -GA 4A38
-GA -GE -GA -GD -GE

Opt

Opt

Opt

Opt

Opt Opt Opt Opt


22-50 22-50 22-50 22-50
Opt
Opt Opt
Opt 60/71
60 60/71

4A38

Opt

Opt

60

M SERIES

MU
-GA

S SERIES

MFZ-KA25/35/50VA

Opt
22-50
Opt
60/71

MLZ-KA25/35/50VA

Opt Opt
22-50 22-50
4A38
Opt Opt
60/71 60/71

SLZ-KA25/35/50VAL/VAQ

SEZ-KD25/35/50/60/71VAL/VAQ

MU 4A38
SUZ MXZ MXZ MXZ MXZ MXZ MXZ MXZ MXZ MXZ MXZ MXZ MXZ SUZ MXZ MXZ MXZ MXZ MXZ MXZ SUZ MXZ MXZ MXZ MXZ MXZ MXZ
-GD -KA -2C -3C -4C -5C -6C -8B -2C -3C -4C -5C -6C -8B -KA -2C -3C -4C -5C -6C -8B -KA -2C -3C -4C -5C -6C -8B

80

80

71

80

Opt

Opt

Opt

4A38

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

4A38
Opt

22-50 22-50 22-50 22-50 22-50 22-50 22-50


60/71

MXY-4A

35

Opt

Opt

MXY-3A

MSH- MSH- MSH- MS- MS- MSMSCHC25/35 GE20/25/35 GE50 GA60 GD80 GE50 GA60 GD80
VA(B)
VB
VB VB
VB VB
VB
VB

Opt

VEW VEW VEW VEW VEW VEW VEW

MXY-2E

80

Opt 10-18
Opt 24/26

Opt

SEZ-KD (25/35/50/60/71)

MXY-4A

80

Opt 10-18
Opt

MXY-3A
MSZ-

Opt

4A38
Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

60/71 60/71 60/71 60/71

Oil Mist Filter

Category

Long-life Filter

Indoor Unit

Filter Check Signal

Outdoor Unit

DC Inverter
Joint Lap DC Motor
Reluctance DC Rotary Compressor
High Ceiling Mode
Rare Earth Magnet Rotor (Compressor)
Technology
DC Fan Motor
Low Ceiling Mode
PAM (Pulse Amplitude Modulation)
Auto Fan Speed Mode
Power Receiver and Twin LEV Control
Wide and Long Airflow
Grooved Piping
Convenience
Energy
Econo Cool Energy-saving Feature
On/offSaving
Operation Timer
Pure White
"i save" Mode
Attractive
Auto Vane
Auto Changeover
*1
*1
*1
*1
Fresh-air Intake *1
Anti-allergy Enzyme Filter
Auto Restart
Electrostatic Anti-allergy Enzyme Filter
Low-temperature Cooling
High-efficiency Filter
AirLow-noise
Quality Operation(Outdoor Unit)
Catechin Filter
Ampere Limit Adjustment Nano Platinum Filter
80
Long-life Filter
Operation Lock
Filter Check Signal
Built-in Weekly Timer Function
Horizontal Vane
Rotation, Back-up and 2nd Stage Cut-inVertical
Functions Mode
High Ceiling Mode
System AirPAR-30MAA
Opt Opt Opt Opt Opt Opt
DistributionControl *3
Control
Low Ceiling Mode
PAR-21MAA Control *3
Opt Mode
Opt Opt Opt Opt Opt
Auto Fan Speed
Centraliesd On/Off Control Wide
*3 and Long
Functions
Opt Airflow
Opt Opt Opt Opt Opt
Timer
System Group Control *3 On/Off Operation
Opt Opt Opt Opt Opt Opt
"I save" Mode
M-NET Connection *3
Opt Opt Opt Opt Opt Opt
Auto Changeover
COMPO *4
Auto Restart
Low-temperature Cooling
Convenience
MXZ Connection
*2
*2
*2
*2
*2
Low-noise Operation
Installation Cleaning-free Pipe Reuse
Ampere Limit Adjustment
Reuse of Existing Wiring Operation Lock
Built-in Weekly Timer Function80
Wiring/Piping Correction Function
Cleaning-free Pipe Reuse
Drain Pump
Wiring/Piping Correction Function
Installation
Pump Down Switch
Drain Pump
Flare Connection
Flare Connection
Easy Clean
Maintenance Quick Clean Body
Maintenance
Self-Diagonosis Function (Check Code Display)
Self-Diagnosis Function(Check Code
Display)Recall Function
Failure

MSZ-EF (25/35/50)
MXZ-2C

MXZ-3C

MXZ-4C

Air
Horizontal Vane
Distribution
Vertical Vane

Functions

4C80

VEW
*1

*1

VEW
*1

Opt

*1

MSZ-GE (25/35/50/60/71)
MXZ-5C

Opt

*1

MXZ-2C

60/71

60/71 60/71 60/71 60/71

60/71

60/71 60/71 60/71 60/71

VEW
*1

MXZ-6C

VEW
*1

*1

Opt

MXZ-3C

MXZ-4C

MXZ-5C

MLZ-KA (25/35/50)
MXZ-6C

MXZ-2C

MXZ-3C

4C80

MXZ-4C

PLA-RP (50/60/71)
MXZ-5C

MXZ-6C

MXZ-3C

MXZ-4C

4C80

MXZ-6C

MXZ-2C
VAQ
VAQ VAQ MXZ-4C
VAQ VAQ
VAQ VAQMXZ-3C

4C80

MXZ-5C

MXZ-6C

4C80

VEW
*1

Opt

*1

*1

*1

*1

*1

*1

*1

*1

*1

*1

*1

*1

Opt 25-50

Opt 25-50
Opt 60

Opt 25-50
Opt 60/71

Opt 25-50
Opt 60/71

Opt 25-50
Opt 60/71

Opt

Opt

Opt

Opt

Opt

25-50

25-50
60

25-50
60/71

25-50
60/71

25-50
60/71

Opt

Opt

Opt

Opt

Opt

60/71

60/71

Opt

*1

*1

*1

80

80

80

*1

*1

Opt

60/71

SEZ-KD (25/35/50/60/71)

MXZ-5C

*1

Opt

*1

*1

Opt

80

*1

*1

*1

*1

*1

*1

*1

*1

*1

*1

*1

*1

*1

*1

Opt
80

80

80

60 60/71 60/71 60/71 60/71

60

60/71

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

60
Opt

Opt

60/71
Opt Opt

60/71
Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

*1 Opt

Opt

*1Opt

Opt

Opt

Opt

Opt

*1 Opt

Opt

*1Opt

Opt

Opt

Opt

Opt

*1 Opt

Opt

Opt

Opt

Opt

*1 Opt

Opt

*1Opt

Opt

Opt
*1

Opt

Opt

*1

Opt

Opt

*1 Opt

Opt

Opt
*1

Opt

Opt

Opt

Opt

*1 Opt

Opt

*1Opt

Opt

Opt

Opt

Opt

Opt

*2

*2

*2

*2

*2

*2

*2

*2

*2

*2

*2

*2

*2

*2

*2

*2

*2

*2

*2

*2

*2

*2

*2

*2

*2

*2

*2

*2

*2

*2

*2

*2

Opt

Opt

Opt

Opt

Opt

Opt

*2

*1

*2

*1

22-50*2 22-50*2

*2

*2

*1

4C80

4C80

*1

60

80

60/71
4C80

*1

*1

*1

*2

4C80
80

80

*2

*1

60/71

*1

*2

4C80
60/71

60/71

4C80
80

4C80

*2

*1

*2

*1

4C80
80

80

4C80
Opt

Opt

80

4C80
Opt

Opt

Opt

Opt

*1 When multiple indoor


units
connected
Failure
Recall
Functionto an MXZ outdoor unit are runnning at the same time, simultaneours cooling and heating is not possible.
*2 Smart Set is available for MSY-GE10/13/18VA, "i save" mode is available for MSY-GE24/26VA

13

14

MXY

SELECTION
Choose from three types of indoor units and three types of outdoor units.
Create the system that best matches the room shapes and the number of rooms.

STEP 1

SELECT INDOOR UNITS


Select the indoor unit to be installed in each room.

Wall-mounted

Cassette

Ceiling-concealed

SERIES
MSY-EF

MSY-GE(10-18)

MLZ-KA

PLA-RP

SEZ-KD

MSY-GE(24-26)

SELECT OUTDOOR UNITS

STEP 2

Select the best outdoor unit based on the number of indoor units and overall system capacity required.

2-port

3-port

4-port

Connect up to 2 indoor units

Connect up to 3 indoor units

Connect up to 4 indoor units

MXY-2E20VA

MXY-3A28VA

MXY-4A28VA

MXY-4A38VA

CHECK SYSTEM COMPATIBILITY

STEP 3

Possible combinations depends on the outdoor unit chosen. Please check the following points.

Check Indoor Units

Refer to the Indoor Unit Compatibility Table to check if the indoor units selected can be used with
the outdoor unit selected. (Indoor units not listed in the table cannot be used.)

Check Indoor Unit Capacity


Combination

Refer to the Combination Table in data book to check if the capacity combination of the indoor unit
selected is connectable. (Combinations not listed cannot be connected.)

If the desired combination cannot be found, please change either the indoor or outdoor unit
to match one of the combinations shown in the tables.

15

16

MXY

MSY-E

SERIES

Our Inverter Technology adjusts capacity in response to conditions such as


the difference between the outside and inside air temperatures, allowing
our air conditioners to run more efficiently and reduce energy costs.

SERIES

MSY-EF10/13/18VAW

White

MSY-EF10/13/18VAS

Silver

MSY-EF10/13/18VAB

Black

Developed to complement modern interior room


dcor, StarMEX ZEN air conditioners are available in
three colors specially chosen to blend in naturally
wherever installed.

Stylish Line-up Matches


Any Room Dcor
2-port

3-port

MXY-2E20VA

The streamlined wall-mounted indoor units have eloquent


silver-bevelled edges, expressing sophistication and quality.
Combining impressively low power consumption and quiet
yet powerful performance, these units provide a bestmatch scenario for diverse interior designs while simultaneeously ensuring maximum room and energy savings.

4-port

4-port

MXY-4A38VA

MXY-3A28VA
MXY-4A28VA

EXAMPLE SYSTEM
MSY-EF

MSY-GE

PLA-RP

Quiet Comfort All Day Long

Superior Exterior
and Operating Design Concept

Mitsubishi Electrics advanced Silent Mode fan speed setting provides super-quiet operation as low as 21dB for EF10/13 models. This
unique feature makes the StarMEX ZEN series ideal for use in any situation.

The indoor unit of the StarMEX ZEN keeps its amazingly thin form
even during operation. The only physical change notable is the
movement of the variable vent. As a result, a slim attractive look is
maintained.

Noise Level

Closed

Human

Subway car
interior

Quiet passenger
car interior
(40km/h)

Library interior

80dB

60dB

40dB

Open

hearing limits
Sound of
rustling leaves (Extremely quiet)

MLZ-KA
MXY-4A38VA

10dB

21dB

Only
(for EF10/13 models)

Handle Up to 4 Rooms with a Single Outdoor Unit


The MXY Series offers a four-system line-up to choose from, ranging between 5.0 and 9.2kW. All of them are compatible with specific M, S and
P series indoor units. A single outdoor unit can handle a wide range of building layouts.

MXY SERIES

4A38

2A/3A

Built-in Weekly Timer Function


Easily sets desired temperatures and operation start/stop times to match lifestyle patterns. Reduce wasted energy consumption by using the timer
to prevent forgetting to turn off the unit and eliminate temperature setting adjustments.

3A/4A

Cooling Only MULTI

Type
Model Name
Power Supply (V/Phase/Hz)
Cooling

Capacity
Input
Dimensions

Outdoor

Ext. Piping

Air Volume
Sound Level (SPL)
Breaker Size

MXY-2E20VA
Rated
Min - Max
Rated
HWD
Weight
Cooling
Cooling

Liquid
Diameter
Gas
Total Piping Length (max)
Each Indoor Unit Piping Length
Max. Height

kW
kW
kW
mm
kg
m3/min
dB(A)
A
mm
mm
m
m
m

5.0
1.10 - 6.55
1.44
550 - 800 - 285
38
31
49
15
6.35 2
9.52 2
30
20
15 (10)*

"Guaranteed Operating
Cooling
C
-10 ~ +46
Range(Outdoor)"
*If the outdoor unit is installed higher than the indoor unit, max. height is reduced to 10m.

17

Inverter Cooling Only


MXY-3A28VA
MXY-4A28VA
230/Single/50
7.5
7.5
2.9 - 8.9
3.7 - 8.9
2.18
2.16
710 - 840 - 330
57
58
42.1
42.1
49
49
25
25
6.35 3
6.35 4
9.52 3
9.52 3 + 12.7 1
60
60
25
25
15 (10)*
15 (10)*
-10 ~ +46

-10 ~ +46

MXY-4A38VA
9.2
3.7 - 11.2
2.45
900 - 900 - 320
67
42.2
46
25
6.35 4
9.52 3 + 12.7 1
70
25
15 (10)*
-10 ~ +46

Electrostatic
Anti-allergy

Nano
Platinum

Optional

Optional

Optional

4A

Optional

Type
Model Name
Power Supply (V/Phase/Hz)
Air Volume
Silent-Lo-Mid-Hi-SHi*
Cooling
SPL
Operating Current (max.)
Demensions HWD
Weight
Diameter
Ext.Piping
*SHi : Super High

Liquid/Gas

MSY-EF10VAW/B/S
3

m /min
dB(A)
mm
kg
mm

4.0 - 4.6 - 6.3 - 8.3 - 10.5


21 - 23 - 29 - 36 - 42
0.14
299 - 895 - 195
11.5
6.35/9.52

Cooling Only
MSY-EF13VAW/B/S
Outdoor (230/Single/50)
4.0 - 4.6 - 6.3 - 8.3 - 10.5
21 - 24 - 29 - 36 - 42
0.14
299 - 895 - 195
11.5
6.35/9.52

MSY-EF18VAW/B/S
5.8 - 6.8 - 7.9 - 9.3 - 11.0
30 - 33 - 36 - 40 - 43
0.18
299 - 895 - 195
11.5
6.35/12.7

18

MSY-GE10/13/18VA

MLZ-KA25/35/50VA

MSY-G

MLZ

MSY-GE24/26VA

SERIES

The standard model MSY-G units provide excellent energy savings and operation is
impressively silent. A vast series line-up is ready to ensure comfortable room
environments in response to your air conditioning needs.

SERIES

Introducing a new type of ceiling cassette for the Multi-Split Series with streamed
interior dimensions and a sharp, sleek appearance.

Ceiling Mounted

10/13
Only

Wide Line-up

Quiet Operation

Five different indoor units (Model 10-26) are available to meet your
diversified air conditioning needs.

A Silent Mode setting has been added to the fan speed settings,
ensuring super-quiet operation below 20dB for model sizes 13 and
under. Perfect for the bedroom; its so quiet youll check to see if its on.

MSY-GE10/13/18VA

19dB

MSY-GE24/26VA
24/26

Stylish and Compact

Nano Platinum Filter

An elegant, high-quality look is achieved through the new stylish


design adopted for indoor units. The simple ergonomic square shape
and pure white color express a sense of sophistication that matches
well with virtually any interior dcor.

This filter incorporates nanometre-sized platinum-ceramic particles


that generate stable antibacterial and deodourising effects. The size
of the three-dimensional surface has been increased as well, enlarging the filter capture area. These features give the Nano Platinum
Filter of the MSY-GE24/26 models better dust collection performance than conventional filters. The superior air-cleaning effectiveness raises room comfort yet another level.

Fits neatly above


800mm-wide doors.

MSY-GE10/13/18VA

800mm

Only 798mm

Nano
Platinum

Slim Body

Access door not required

Installing the ceiling-mounted MLZ


Series unit in a room creates a more
spacious feel that enhances room
comfort. This overhead format is also
an excellent solution when lighting
equipment is installed at the centre
of the room and fixtures such as
book shelves are mounted on wall
surfaces.

The new units are designed with a slim body (only 175mm high), ensuring easy installation even when low ceiling cavities limit installation space. The need for ceiling cavity service space is also eliminated, further reducing the dimensions required for installation.

Air Volume Settings by Ceiling Height

Auto Vane Control

Dual-level airflow selection is engineered to accommodate specific


ceiling heights. This is a key feature for adjusting airflow effectively
when it is either too strong or too weak due to being mismatched
with the height of the ceiling.

Outlet vanes can be moved left


and right, and up and down
using the remote controller.
This improved airflow control
feature solves the problem of
drafts.

175mm

25

35

50

Standard

2.4m

2.4m

2.4m

High ceiling

2.7m

2.7m

2.7m

Left and Right


Up and Down

Easy Installation
A built-in drain pump (500mm lift) and flexible drain joints make attaching the drain hose in the ceiling cavity easy, resulting in simple and fast
installation. Tight yet flexible fittings eliminate the need of wrapping with heat-insulation tape, and ensure that pipe and drain cover connections
are free of condensation.
Drain

In the case of MSY-GE10-18


It is okay to wash the filter with water
(air-cleaning effect is maintained)

i save Mode
i save is a simplified setting function that recalls the preferred
(preset) temperature by pressing a single button on the remote controller. Press the same button twice in repetition to immediately
return to the previous temperature setting. Using this function contributes to comfortable, waste-free operation, realizing the most
suitable air conditioning settings and saving on power consumption
when, for example, leaving the room or going to bed.

Easy joint
connections!

3D surface (Waved surface)


24/26*2

Cooling

Installation Example

Piping Supporters

Built-in drain pump


secures drainage
water lift of 500mm

Cooling

Insulation material pretreatment


eliminates need for wrapping.

Refrigerant pipe

Insulating material wrapping


only required from this point

24 c

22 c

Flexible drain joints

Flexible drain joints simplify


drain piping work in narrow ceiling areas

The newly adopted insulation-free cover eliminates


the need for wrapping pipes with insulation tape and
prevents the forming of condensation.

Drain cover
10 - 18

24/26

10 - 18

24/26

24/26

24/26*1

24/26*2

Nano
Platinum

Electrostatic
Anti-allergy
Optional

24/26

Easy

Mounting Plate

Suspension work simplified with


well-designed mounting plates

Optional

Secure one side

Push the unit to the other side


Secure the opposite side

Move unit to the centre

4A

Optional

Optional

Optional
Optional

Type
Model Name

Power Supply (V/Phase/Hz)


Air
Silent-LoVolume
Cooling
Mid-Hi-SHi*
SPL
Operating Current (max.)
Demensions HWD

MSY-GE10VA

MSY-GE13VA

Cooling Only
MSY-GE18VA
Outdoor (230/Single/50)

m3/min

4.2 - 4.9 - 6.7 - 8.9 - 11.4

4.2 - 4.9 - 6.7 - 9.2 - 12.8

6.5 - 7.8 - 9.6 - 11.8 - 15.1

N/A - 9.7 - 13.3 - 15.4 - 17.9

9.7 - 11.5 - 13.3 - 15.4 - 17.9

dB(A)

19 - 21 - 29 - 36 - 40
0.22
295 - 798 - 232
10
6.35/9.52

19 - 22 - 30 - 36 - 45
0.29
295 - 798 - 232
10
6.35/9.52

28 - 33 - 38 - 44 - 49
0.39
295 - 798 - 232
10
6.35/12.7

N/A - 30 - 40 - 45 - 49
0.55
325 - 1100 - 238
16
9.52/15.88

30 - 37 - 41 - 45 - 49
0.55
325 - 1100 - 238
16
9.52/15.88

mm
kg
mm

Weight
Ext.Piping Diameter Liquid/Gas
*SHi : Super High
*1 Functions and specification may differ depending on the market.
*2 Smart Set is available for MSY-GE10/13/18VA.

19

MSY-GE24VA*

MSY-GE26VA

Optional
4A

Type
Model Name
Power Supply (V/Phase/Hz)
Air Volume
Lo-Mid-Hi
Cooling
SPL
Operating Current (max.)
Demensions HWD

Weight
Ext.Piping

Diameter

Liquid/Gas

Optional

m3/min
dB(A)
mm
kg
mm

Optional

Optional

MLZ-KA25VA

Cooling Only
MLZ-KA35VA
Outdoor (230/Single/50)

MLZ-KA50VA

7.2 - 8.0 - 8.8


29 - 32 - 35
0.4
175 - 1102 - 360
15
6.35/9.52

7.3 - 8.4 - 9.4


31 - 34 - 37
0.4
175 - 1102 - 360
15
6.35/9.52

8.3 - 9.8 - 11.4


34 - 38 - 43
0.4
175 - 1102 - 360
15
6.35/12.7

20

PLA-RP50/60/71
MLZ-KA25/35/50VA

SEZ

PLA
MLZ

SERIES
SERIES

Slim Body

Access door not required

Installing the ceiling-mounted MLZ


Series unit in a room creates a more
spacious feel that enhances room
comfort. This overhead format is also
an excellent solution when lighting
equipment is installed at the centre
of the room and fixtures such as
book shelves are mounted on wall
surfaces.
Individual Vane Settings
Optimum airflow settings provide maximum
comfort throughout the room.

The new units are designed with a slim body (only 175mm high), ensuring easy installation even when low ceiling cavities limit installation space. The need for ceiling cavity service space is also eliminated, further reducing the dimensions required for installation.

175mm

Optimum Airflow

Wide Airflow
Wide-angle outlets distribute airflow
to all corners of the room.

Air Volume Settings by Ceiling Height

Auto Vane Control

Standard

25

35

50

2.4m

2.4m

2.4m

2.7m

2.7m New 4-Way Ceiling Cassette

Horizontal

2.7m

AirflowHigh
direction
at
ceiling
each vane can be set
using the wired remote
controller.

Setting

Wide Airflow

The combination of individual vane setting,


which enables the optimal outlet setting for
each room layout, and the wide airflow function
works to ensure even temperature distribution
throughout each room. The result is uniformly
comfortable air conditioning.

72 airflow patterns

A built-in drain pump (500mm lift) and flexible drain joints make attaching the drain hose in the ceiling cavity easy, resulting in simple and fast
installation. Tight yet flexible fittings eliminate the need of wrapping with heat-insulation tape, and ensure that pipe and drain cover connections
are free of condensation.

The New Swing Function Cools All Corners of the Room


Drain

Installation Example

Piping Supporters

Wave Airflow Operation


Easy
joint
Wave Airflow is essentially
the
advanced control of the vanes
connections!
drain joints
directing
the
airflow
from the unit. Blown-air is repeatedFlexible
dispersed
Built-in
drain
pump
from
the unit
in horizontal and downward directions at time-lagged
secures
drainage
waterto
liftprovide
of 500mm
intervals
uniform heating throughout theInsulating
room. material wrapping
only required from this point

Thermograph of Wave Control Effect

Refrigerant pipe

Downward

Horizontal Airflow
Wave Airflow
Insulation material pretreatment
eliminates need for wrapping.

Indoor Unit

Indoor Unit

Downward

Temperature gap
Uneven temperature distribution

Easy

Mounting Plate

Minimized temperature gap


Uniform cool air is supplied throughout the room,
minimizing uneven temperature distribution.

Suspension work simplified with


well-designed mounting plates

Wide Selection of Fan Speed and Static Pressure Level


Three fan speeds (Low - Mid - High) and four static pressure levels (5 - 15 - 35 - 50Pa) are available by using the DC fan motor to meet
various needs.

Drain Pump (Optional)


The PAC-KE07DM-E drain pump is now available as an option. With the pump, a drain hose length of up to 550mm can be used,
leading to increased installation possibilities.

Flexible drain joints simplify


drain piping work in narrow ceiling areas

The newly adopted insulation-free cover eliminates


the need for wrapping pipes with insulation tape and
prevents the forming of condensation.

Drain cover

Downward Downward

Vertical swinging mode is adapted in the case of cooling operation

Air inlet
Air outlet
Access door
Ceiling surface
Canvas duct
Air filter
Inlet grille

SEZ-KD35VAL

Up and Down

Downward

A
B
C
D
E
F
G

200

Individual Vane
Left and Right

Fixed

Adjustable

Easy Installation

990

Dimension

moved left
and right, and up and down
using the remote controller.
This improved
Previous airflow control
model the problem of
feature solves
drafts.

ceiling heights. This is a key feature for adjusting airflow effectively


when
it is either too strong or too weak due to being mismatched
2-, 3-, 4-way airflow
patternthe
selection
with
height of the ceiling.

Compact Ceiling-concealed Units


Only the intake-air grille and outlet vents are visible when using this ceiling-concealed indoor unit. The rest of the unit is conveniently hidden in the
ceiling cavity, essentially leaving the ceiling and walls free of bulky looking devices and maintaining a high-class interior dcor. The compact units
require minimal space and can be installed in buildings with lowered ceilings, where exposed units were the rule in the past.

Image of multi-directional
air conditioning

In addition to the selection of variable airflow patterns (i.e., 2-,


The outlets are larger than those of previous
3- or 4-way), this function allows the independent selection of
models and the shape has been improved for
vertical
airflow levels
for selection
each vane, thereby
maintaining
combetter
wide-angle ventilation.
Dual-level
airflow
is engineered
toa accommodate
specific
Outlet vanes can be
fortable room environment with even temperature distribution.

* Optional shuffle placement is required


for 2- and 3-way patterns.

SEZ-KD25-71VAL

This concealed ceiling-mounted indoor unit series is compact, and fits easily into
rooms with lowered ceilings. Highly reliable energy-saving performance makes it
a best match choice for concealed unit installations.

The
Introducing
incorporation
a new
of wide
type air-outlet
of ceilingand
cassette
the i-see
for Sensor
the Multi-Split
enhances
Series
airflow
with
distribution
streamed
control,
interiorachieving
dimensions
an enhanced
and a sharp,
levelsleek
of comfort
appearance.
throughout the room. The synergy of
higher energy efficiency and more comfortable room environment results in the utmost
user satisfaction.

Ceiling Mounted

SERIES

Secure one side

Temperature distribution comparison approximately 20min after turning on a PLA-RP71BA


4-Way ceiling cassette. The measurement point
for comparison is a plane 1.2m above the floor.

Push the unit to the other side


Secure the opposite side

Move unit to the centre


4A

Optional
4A

Optional
Optional

Optional

Type
Model Name
Power Supply (V/Phase/Hz)
Air Volume Lo-Mid2Cooling
Mid1-Hi
SPL
Operating Current (max.)
Demensions HWD
Weight
Ext.Piping

21

Diameter

Liquid/Gas

m3/min
dB(A)
mm
kg
mm

PLA-RP50BA

Cooling Only
PLA-RP60BA
Outdoor (230/Single/50)

PLA-RP71BA

12.0 - 14.0 - 16.0 - 18.0


28 - 29 - 31 - 32
0.36
258 - 840 - 840
22
6.35/12.7

12.0 - 14.0 - 16.0 - 18.0


28 - 29 - 31 - 32
0.36
258 - 840 - 840
23
6.359.52/15.88

14.0 - 16.0 - 18.0 - 21.0


28 - 30 - 32 - 34
0.51
258 - 840 - 840
23
9.52/15.88

Type
Model Name
Power Supply (V/Phase/Hz)
Air Volume
Lo-Mid-Hi
Cooling
SPL
Operating Current (max.)
Demensions HWD
Weight
Liquid/Gas
Ext.Piping Diameter
External Static Pressure

Optional

m3/min
dB(A)
mm
kg
mm

Optional

SEZ-KD25VAL

SEZ-KD35VAL

Cooling Only
SEZ-KD50VAL
Outdoor (230/Single/50)

SEZ-KD60VAL

SEZ-KD71VAL

5.5 - 7.0 - 9.0


23 - 26 - 30
0.39
200 - 790 - 700
18
6.35/9.52
5/15/35/50

7.0 - 9.0 - 11.0


23 - 28 - 33
0.46
200 - 990 - 700
21
6.35/9.52
5/15/35/50

10.0 - 12.5 - 15.0


30 - 34 - 37
0.63
200 - 990 - 700
23
6.35/12.7
5/15/35/50

12.0 - 15.0 - 18.0


30 - 34 - 38
0.63
200 - 1190 - 700
27
6.35/15.88
5/15/35/50

12.0 - 16.0 - 20.0


30 - 35 - 40
0.84
200 - 1190 - 700
27
9.52/15.88
5/15/35/50

22

Indoor Unit Compatibility Table


Possible combinations of outdoor units and indoor units are shown below.
Outdoor Unit

MXY2E20VA

Indoor Unit

3A28VA

4A28VA

4A38VA

MSY-EF10VA

Wall-mounted

MSY-EF13VA

MSY-EF18VA

MSY-EF

MSY-GE10VA

MSY-GE13VA
MSY-GE(10-18)

MSY-GE18VA

MSY-GE(24-26)

MSY-GE24VA

MSY-GE26VA

1-way cassette

MLZ-KA25VA

MLZ-KA35VA

MLZ Series

4-way cassette

MLZ-KA50VA

PLA-RP50BA

PLA-RP60BA

PLA Series

Ceiling-concealed

PLA-RP71BA

SEZ-KD35VAL

SEZ-KD50VAL

SEZ-KD60VAL

SEZ Series

SEZ-KD71VAL

23

24

MXZ

SELECTION
Choose from three types of indoor units and five types of outdoor units.
Create the system that best matches the room shapes and the number of rooms.

STEP 1

SELECT INDOOR UNITS


Select the indoor unit to be installed in each room.

Wall-mounted

Cassette

Ceiling-concealed

SERIES
MSZ-EF

MSZ-GE(25/35/50)

MLZ-KA

PLA-RP

SEZ-KD

MSZ-GE(60/71)

SELECT OUTDOOR UNITS

STEP 2

Select the best outdoor unit based on the number of indoor units and overall system capacity required.

2-port

3-port

4-port

Connect up to 2 indoor units

Connect up to 3 indoor units

Connect up to 4 indoor units

MXZ-2C52VA

5-port

MXZ-3C68VA

Connect up to 5 indoor units

MXZ-4C71VA

6-port

MXZ-4C80VA

Connect up to 6 indoor units

MXZ-5C100VA

MXZ-6C120VA

CHECK SYSTEM COMPATIBILITY

STEP 3

Possible combinations depends on the outdoor unit chosen. Please check the following points.

Check Indoor Units

Refer to the Indoor Unit Compatibility Table to check if the indoor units selected can be used with
the outdoor unit selected. (Indoor units not listed in the table cannot be used.)

Check Indoor Unit Capacity


Combination

Refer to the Combination Table in data book to check if the capacity combination of the indoor unit
selected is connectable. (Combinations not listed cannot be connected.)

If the desired combination cannot be found, please change either the indoor or outdoor unit
to match one of the combinations shown in the tables.

25

26

MXZ

MSZ-E

SERIES

SERIES

MSZ-EF25/35/50VEW

White

MSZ-EF25/35/50VES

Silver

MSZ-EF25/35/50VEB

Black

Developed to complement modern interior room


dcor, Kirigamine ZEN air conditioners are available
in three colors specially chosen to blend in naturally
wherever installed.

Advancements in the MXZ Series include efficiency and flexibility in system


expansion capabilities. The best solution when requiring multi-system air
conditioning needs.

Stylish Line-up Matches


Any Room Dcor

2-port

3-port

MXZ-2C52VA

4-port

4-port

5-port

6-port

MXZ-4C80VA
MXZ-5C100VA

MXZ-3C68VA
MXZ-4C71VA

The streamlined wall-mounted indoor units have eloquent


silver-bevelled edges, expressing sophistication and quality.
Combining impressively low power consumption and quiet
yet powerful performance, these units provide a bestmatch scenario for diverse interior designs while simultaneeously ensuring maximum room and energy savings

MXZ-6C120VA

EXAMPLE SYSTEM
MSZ-EF

(example of MXZ-6C120VA system)

MSZ-GE

Quiet Comfort All Day Long

Superior Exterior
and Operating Design Concept

Mitsubishi Electrics advanced Silent Mode fan speed setting provides super-quiet operation as low as 21dB for EF25/35 models. This
unique feature makes the Kirigamine ZEN series ideal for use in any
situation.

The indoor unit of the Kirigamine ZEN keeps its amazingly thin form
even during operation. The only physical change notable is the
movement of the variable vent. As a result, a slim attractive look is
maintained.

Noise Level

MSZ-GE

Closed

Human

Subway car
interior

Quiet passenger
car interior
(40km/h)

Library interior

80dB

60dB

40dB

Open

hearing limits
Sound of
rustling leaves (Extremely quiet)

MLZ-KA

10dB

21dB

Only
(for EF25/35 models)

PLA-BA
MXZ-6C120VA

Built-in Weekly Timer Function

SEZ-KD

Handle Up to 6 Rooms with a Single Outdoor Unit


The MXZ Series offers a six-system line-up to choose from, ranging between 5.2 and 12.0kW. All of them are compatible with specific M, S and
P series indoor units. A single outdoor unit can handle a wide range of building layouts.

MXZ SERIES

4C80-6C

2C/3C/4C

Easily sets desired temperatures and operation start/stop


times to match lifestyle patterns. Reduces wasted energy
consumption by using the timer to prevent forgetting to turn
off the unit and eliminate temperature setting adjustments.
Easy Set-up Using Dedicated Buttons

The remote controller is equipped with buttons that are


used exclusively for setting the Weekly Timer. Setting
operation patterns easy and quick.

3C - 6C

INVERTER MULTI

Type
Model Name
Power Supply (V/Phase/Hz)
Rated
Capacity
Min - Max
Cooling
Rated
Input
Rated
Capacity
Min - Max
Heating
Rated
Input
HWD
Dimensions
Weight
Cooling
Air Volume
Heating
Outdoor

MXZ-2C52VA
kW
kW
kW
kW
kW
kW
mm
kg
m3/min
m3/min

5.2
1.1 - 6.0
1.3
6.4
1.0 - 7.0
1.61
550 - 800 - 285
38
32.9

33.3
dB(A)
49
Sound Level Cooling
(SPL)
Heating
dB(A)
50
A
15
Breaker Size
Liquid
mm
6.35 2
Diameter
Gas
mm
9.52 2
Ext.
m
30
Total Piping Length (max)
Piping
m
20
Each Indoor Unit Piping Length
m
15 (10)*
Max. Height
C
-10 ~ +43
"Guaranteed Operating Cooling
Range(Outdoor)"
Heating
C
-15 ~ +24
* If the outdoor unit is installed higher than the indoor unit, max.height is reduced to 10m.

27

Inverter Heat Pump


MXZ-4C71VA
MXZ-4C80VA
MXZ-5C100VA
230/Single/50
6.8
7.1
8.0
10.0
2.9 - 8.4
3.7 - 8.8
3.7 - 9.2
3.9 - 11.0
1.78
1.68
1.955
2.80
8.6
8.6
9.4
12.0
2.6 - 10.6
3.4 - 10.7
3.4 - 11.6
4.1 - 14.0
2.05
1.71
1.93
2.84
710 - 840 - 330
900 - 900 - 320
57
58
67
68
42.1
42.1
42.1
56.6

MXZ-3C68VA

43
48
52
25
6.35 3
9.52 3
60
25
15 (10)*
-10 ~ +43
-15 ~ +24

43
48
52
25
6.35 4
9.52 3 + 12.7 1
60
25
15 (10)*
-10 ~ +43
-15 ~ +24

43.8
46
48
25
6.35 4
9.52 3 + 12.7 1
70
25
15 (10)*
-10 ~ +43
-15 ~ +24

59.3
51
54
25
6.35 5
9.52 4 + 12.7 1
80
25
15 (10)*
-10 ~ +43
-15 ~ +24

A maximum of 4ON or OFF timers can be set for individual days of the week
A maximum of 28 ON or OFF timers can be set for a week.

Setting

E.g. : Runs at 24C from waking up to leaving home, and runs at 27C from
getting home to going to bed on weekdays.
Runs at 27C from waking up late to going bed early on weekends
Mon

Setting1
ON

Fri

6:00

Sat
Sun

MXZ-6C120VA
12.0
3.5 - 13.5
3.61
14.0
3.5 - 16.5
3.47
1070 - 900 - 320
88
55.4
69.9
55
57
32
6.35 6
9.52 5 + 12.7 1
80
25
15 (10)*
-10 ~ +43
-15 ~ +24

Electrostatic
Anti-allergy

24C

Setting2
OFF

8:30
Setting1
ON

Setting3
ON

27C

17:30

Setting4
OFF
22:00
Setting2
OFF

27C

8:00

21:00

Nano
Platinum

Optional

Optional

4C/5C/6C

Optional

4C/5C/6C

Optional

Type
Model Name
Power Supply (V/Phase/Hz)
Air Volume
Cooling
SPL
Air Volume
Heating
SPL
Operating Current (max.)
HWD
Demensions
Weight
Diameter
Ext.Piping
*SHi : Super High

m /min
Silent-Lo-Mid-Hi-SHi*
m3/min
Silent-Lo-Mid-Hi-Shi*

dB(A)
dB(A)

Liquid/Gas

mm
kg
mm

MSZ-EF25VEW/B/S

Inverter Heat Pump


MSZ-EF35VEW/B/S
Outdoor (230/Single/50)

MSZ-EF50VEW/B/S

4.0 - 4.6 - 6.3 - 8.3 - 10.5


21 - 23 - 29 - 36 - 42
4.0 - 4.6 - 6.2 - 8.9 - 11.9
21 - 24 - 29 - 37 - 45
0.3
299 - 895 - 195
11.5
6.35/9.52

4.0 - 4.6 - 6.3 - 8.3 - 10.5


21 - 24 - 29 - 36 - 42
4.0 - 4.6 - 6.2 - 8.9 - 12.7
21 - 24 - 30 - 38 - 46
0.3
299 - 895 - 195
11.5
6.35/9.52

5.8 - 6.8 - 7.9 - 9.3 - 11.0


30 - 33 - 36 - 40 - 43
6.4 - 7.3 - 9.0 - 11.1 - 13.2
30 - 33 - 37 - 43 - 49
0.4
299 - 895 - 195
11.5
6.35/12.7

28

MSZ-GE25/35/50VA

MLZ-KA25/35/50VA

MSZ-G

MLZ

MSZ-GE60/71VA

SERIES

The standard model MSZ-G units provide excellent energy savings and operation is
impressively silent. A vast series line-up is ready to ensure comfortable room
environments in response to your air conditioning needs.

SERIES

Introducing a new type of ceiling cassette for the Multi-Split Series with streamed
interior dimensions and a sharp, sleek appearance.

Ceiling Mounted
25-35
Only

Wide Line-up

Quiet Operation

Five different indoor units (Model 25-71) are available to meet your
diversified air conditioning needs.

A Silent Mode setting has been added to the fan speed settings,
ensuring super-quiet operation below 20dB for model sizes 35 and
under. Perfect for the bedroom; its so quiet youll check to see if its on.

MSZ-GE25/35/50VA

19dB

MSZ-GE60/71VA

Installing the ceiling-mounted MLZ


Series unit in a room creates a more
spacious feel that enhances room
comfort. This overhead format is also
an excellent solution when lighting
equipment is installed at the centre
of the room and fixtures such as
book shelves are mounted on wall
surfaces.

The new units are designed with a slim body (only 175mm high), ensuring easy installation even when low ceiling cavities limit installation space. The need for ceiling cavity service space is also eliminated, further reducing the dimensions required for installation.

Air Volume Settings by Ceiling Height

Auto Vane Control

Dual-level airflow selection is engineered to accommodate specific


ceiling heights. This is a key feature for adjusting airflow effectively
when it is either too strong or too weak due to being mismatched
with the height of the ceiling.

Outlet vanes can be moved left


and right, and up and down
using the remote controller. This
improved airflow control feature
solves the problem of drafts.

175mm

60/71

Stylish and Compact

Nano Platinum Filter

An elegant, high-quality look is achieved through the new stylish


design adopted for indoor units. The simple ergonomic square shape
and pure white color express a sense of sophistication that matches
well with virtually any interior dcor.

This filter incorporates nanometre-sized platinum-ceramic particles


that generate stable antibacterial and deodourising effects. The size
of the three-dimensional surface has been increased as well, enlarging the filter capture area. These features give the Nano Platinum
Filter of the MSZ-GE60/71 models better dust collection performance than conventional filters. The superior air-cleaning effectiveness raises room comfort yet another level.

Fits neatly above


800mm-wide doors.

MSZ-GE25/35/50VA

Slim Body

Access door not required

800mm

Only 798mm

Nano
Platinum

25

35

50

Standard

2.4m

2.4m

2.4m

High ceiling

2.7m

2.7m

2.7m

Left and Right


Up and Down

Easy Installation

In the case of MSZ-GE25-50


It is okay to wash the filter with water
(air-cleaning effect is maintained)

3D surface (Waved surface)

i save Mode

A built-in drain pump (500mm lift) and flexible drain joints make attaching the drain hose in the ceiling cavity easy, resulting in simple and fast
installation. Tight yet flexible fittings eliminate the need of wrapping with heat-insulation tape, and ensure that pipe and drain cover connections
are free of condensation.
Drain

i save is a simplified setting function that recalls the preferred


(preset) temperature by pressing a single button on the remote controller. Press the same button twice in repetition to immediately
return to the previous temperature setting. Using this function contributes to comfortable, waste-free operation, realizing the most
suitable air conditioning settings and saving on power consumption
when, for example, leaving the room or going to bed.

Heating

Heating

18 c

22 c

Installation Example

Piping Supporters
Easy joint
connections!

Built-in drain pump


secures drainage
water lift of 500mm

Flexible drain joints

Refrigerant pipe

Insulating material wrapping


only required from this point
Insulation material pretreatment
eliminates need for wrapping.

Flexible drain joints simplify


drain piping work in narrow ceiling areas

The newly adopted insulation-free cover eliminates


the need for wrapping pipes with insulation tape and
prevents the forming of condensation.

Drain cover
25 - 50

60/71

25 - 50

60/71

60/71

60/71

Optional

Weight
Ext.Piping Diameter
*SHi : Super High

29

Liquid/Gas

4C/5C/6C

Secure one side

Push the unit to the other side


Secure the opposite side

Move unit to the centre

4C/5C/6C

Optional

Type
Model Name
Power Supply (V/Phase/Hz)
Air
Silent-LoVolume
Cooling
Mid-Hi-SHi*
SPL
Air
Silent-LoVolume
Heating
Mid-Hi-Shi*
SPL
Operating Current (max.)
Demensions HWD

Mounting Plate

Suspension work simplified with


well-designed mounting plates

Optional
4C/5C/6C

Optional

Easy

Nano
Platinum

Electrostatic
Anti-allergy
Optional

60/71

m3/min
dB(A)
m3/min
dB(A)
mm
kg
mm

MSZ-GE25VA

MSZ-GE35VA

Inverter Heat Pump


MSZ-GE50VA
Outdoor (230/Single/50)

MSZ-GE60VA

MSZ-GE71VA

4.1 - 4.8 - 6.7 - 9.1 - 11.3

4.1 - 4.8 - 6.7 - 9.1 - 12.7

6.5 - 7.8 - 9.6 - 11.9 - 15.1

9.8 - 11.3 - 13.4 - 15.6 - 18.3

9.7 - 11.5 - 13.3 - 15.4 - 17.8

19 - 21 - 29 - 36 - 42

19 - 22 - 30 - 36 - 43

28 - 33 - 38 - 44 - 49

29 - 37 - 41 - 45 - 49

30 - 37 - 41 - 45 - 49

4.1 - 4.8 - 6.6 - 9.1 - 11.5

4.1 - 4.8 - 6.7 - 9.1 - 11.5

6.5 - 7.9 - 9.6 - 12.2 - 14.5

9.8 - 11.3 - 13.4 - 15.6 - 18.3

10.2 - 11.5 - 13.3 - 15.4 - 17.8

19 - 21 - 29 - 36 - 42
0.4
295 - 798 - 232
10
6.35/9.52

19 - 22 - 30 - 36 - 42
0.4
295 - 798 - 232
10
6.35/9.52

28 - 33 - 37 - 43 - 48
0.5
295 - 798 - 232
10
6.35/12.7

29 - 37 - 41 - 45 - 49
0.5
325 - 1100 - 238
16
6.35/15.88

30 - 37 - 41 - 45 - 49
0.5
325 - 1100 - 238
16
9.52/15.88

Optional

Optional

Optional

Optional

Optional

4C/5C/6C

Type
Model Name
Power Supply (V/Phase/Hz)
Air Volume
Lo-Mid-Hi
Cooling
SPL
Air Volume
Lo-Mid-Hi
Heating
SPL
Operating Current (max.)
Demensions HWD

Weight
Ext.Piping

Diameter

m /min
dB(A)
m3/min
dB(A)

mm
kg
Liquid/Gas mm

MLZ-KA25VA

Inverter Heat Pump


MLZ-KA35VA
Outdoor (230/Single/50)

MLZ-KA50VA

7.2 - 8.0 - 8.8


29 - 32 - 35
7.0 - 8.2 - 9.2
28 - 32 - 36
0.4
175 - 1102 - 360
15
6.35/9.52

7.3 - 8.4 - 9.4


31 - 34 - 37
7.7 - 8.8 - 9.9
31 - 35 - 38
0.4
175 - 1102 - 360
15
6.35/9.52

8.3 - 9.8 - 11.4


34 - 38 - 43
8.8 - 10.3 - 11.8
34 - 39 - 43
0.4
175 - 1102 - 360
15
6.35/12.7

30

PLA-RP50/60/71
MLZ-KA25/35/50VA

SEZ

PLA
MLZ

SERIES
SERIES

Slim Body

Access door not required

Installing the ceiling-mounted MLZ


Series unit in a room creates a more
spacious feel that enhances room
comfort. This overhead format is also
an excellent solution when lighting
equipment is installed at the centre
of the room and fixtures such as
book shelves are mounted on wall
surfaces. Vane Settings
Individual

The new units are designed with a slim body (only 175mm high), ensuring easy installation even when low ceiling cavities limit installation space. The need for ceiling cavity service space is also eliminated, further reducing the dimensions required for installation.

175mm

Optimum Airflow

Wide Airflow
Wide-angle outlets distribute airflow
to all corners of the room.

Optimum airflow settings provide maximum


comfort throughout the room.

Air Volume Settings by Ceiling Height

Auto Vane Control

ceiling heights. This is a key feature for adjusting airflow effectively


when
it isairflow
either too strong or too weak due to being mismatched
2-, 3-, 4-way
patternthe
selection
with
height of the ceiling.

moved left
and right, and up and down
using the remote controller. This
improved airflow
Previous control feature
solves themodel
problem of drafts.

Standard
AirflowHigh
direction
at
ceiling
each vane can be set
using the wired remote
controller.

25

35

50

2.4m

2.4m

2.4m

2.7m

2.7m

2.7m

Horizontal

Adjustable

Easy Installation

New 4-Way Ceiling Cassette

Setting

Wide Airflow

The
setting,
which enables the optimal outlet setting for
each room layout, and the wide airflow function
works to ensure even temperature distribution
throughout each room. The result is uniformly
comfortable air conditioning.

72 airflow patterns

Wave Airflow Thoroughly Warming All Corners of the Room!

Refrigerant pipe

Downward

Horizontal Airflow
Wave Airflow
Insulation material pretreatment
eliminates need for wrapping.

Indoor Unit

Indoor Unit

Downward

Temperature gap
Uneven temperature distribution

Drain cover

Downward Downward

Wave Airflow is possible only when using the heating mode

SEZ-KD35VAL

Wide Selection of Fan Speed and Static Pressure Level


Three fan speeds (Low - Mid - High) and four static pressure levels (5 - 15 - 35 - 50Pa) are available by using the DC fan motor to meet
various needs.

Drain Pump (Optional)


The PAC-KE07DM-E drain pump is now available as an option. With the pump, a drain hose length of up to 550mm can be used,
leading to increased installation possibilities.

Flexible drain joints simplify


drain piping work in narrow ceiling areas

The newly adopted insulation-free cover eliminates


the need for wrapping pipes with insulation tape and
prevents the forming of condensation.

Easy

Installation Example

Piping Supporters

only required from this point

Air inlet
Air outlet
Access door
Ceiling surface
Canvas duct
Air filter
Inlet grille

Up and Down
combination of individual vane

Downward

Thermograph of Wave Control Effect

A
B
C
D
E
F
G

200

A built-in drain pump (500mm lift) and flexible drain joints make attaching the drain hose in the ceiling cavity easy, resulting in simple and fast
installation. Tight yet flexible fittings eliminate the need of wrapping with heat-insulation tape, and ensure that pipe and drain cover connections
are free of condensation.

Drain

990

Dimension

Individual Vane
Left and Right

Fixed

Wave Airflow Operation


Wave Airflow is essentially
the
advanced control of the vanes
Easy
joint
drain joints
directing the airflow from theconnections!
unit. Blown-air is repeatedFlexible
dispersed
Built-in drain pump
from
the unit
in horizontal and downward directions at time-lagged
secures
drainage
intervals
uniform heating throughout theInsulating
room. material wrapping
waterto
liftprovide
of 500mm

Compact Ceiling-concealed Units


Only the intake-air grille and outlet vents are visible when using this ceiling-concealed indoor unit. The rest of the unit is conveniently hidden in the
ceiling cavity, essentially leaving the ceiling and walls free of bulky looking devices and maintaining a high-class interior dcor. The compact units
require minimal space and can be installed in buildings with lowered ceilings, where exposed units were the rule in the past.

Image of multi-directional
air conditioning

In addition to the selection of variable airflow patterns (i.e., 2-,


The outlets are larger than those of previous
3- or 4-way), this function allows the independent selection of
models and the shape has been improved for
vertical
airflow levels
for selection
each vane, thereby
maintaining
combetter
wide-angle ventilation.
Dual-level
airflow
is engineered
toa accommodate
specific
Outlet vanes can be
fortable room environment with even temperature distribution.

* Optional shuffle placement is required


for 2- and 3-way patterns.

SEZ-KD25-71VAL

This concealed ceiling-mounted indoor unit series is compact, and fits easily into
rooms with lowered ceilings. Highly reliable energy-saving performance makes it
a best match choice for concealed unit installations.

The
Introducing
incorporation
a new
of wide
type air-outlet
of ceilingand
cassette
the i-see
for Sensor
the Multi-Split
enhances
Series
airflow
with
distribution
streamed
control,
interiorachieving
dimensions
an enhanced
and a sharp,
levelsleek
of comfort
appearance.
throughout the room. The synergy of
higher energy efficiency and more comfortable room environment results in the utmost
user satisfaction.

Ceiling Mounted

SERIES

Minimized temperature gap


Warm air is supplied throughout the room,
minimizing uneven temperature distribution.

Temperature distribution comparison approximately 20min after turning on a PLA-RP71BA


4-Way ceiling cassette. The measurement point
for comparison is a plane 1.2m above the floor.

Mounting Plate

Suspension work simplified with


well-designed mounting plates

Secure one side

Push the unit to the other side


Secure the opposite side

Move unit to the centre

Optional
4C/5C/6C

4C/5C/6C

Optional

Optional

Type
Model Name
Power Supply (V/Phase/Hz)
Heating and Air Volume Lo-Mid2-Mid1-Hi
Cooling
SPL
Operating Current (max.)
HWD
Demensions
Weight
Diameter
Liquid/Gas
Ext.Piping

31

4C/5C/6C

Optional

m3/min
dB(A)
mm
kg
mm

PLA-RP50BA

Inverter Heat Pump


PLA-RP60BA
Outdoor (230/Single/150)

PLA-RP71BA

12.0 - 14.0 - 16.0 - 18.0


28 - 29 - 31 - 32
0.36
258 - 840 - 840
22
6.35/12.7

12.0 - 14.0 - 16.0 - 18.0


28 - 29 - 31 - 32
0.36
258 - 840 - 840
23
6.359.52/15.88

14.0 - 16.0 - 18.0 - 21.0


28 - 30 - 32 - 34
0.51
258 - 840 - 840
23
9.52/15.88

Type
Model Name
Power Supply (V/Phase/Hz)
Heating and Air Volume Lo-Mid-Hi
Cooling
SPL
Operating Current (max.)
HWD
Demensions
Weight
Diameter
Ext.Piping
External Static Pressure

Liquid/Gas

m3/min
dB(A)
mm
kg
mm

Optional

4C/5C/6C

Optional

SEZ-KD25VAL

SEZ-KD35VAL

Inverter Heat Pump


SEZ-KD50VAL
Outdoor (230/Single/50)

SEZ-KD60VAL

SEZ-KD71VAL

5.5 - 7.0 - 9.0


23 - 26 - 30
0.39
200 - 790 - 700
18
6.35/9.52
5/15/35/50

7.0 - 9.0 - 11.0


23 - 28 - 33
0.46
200 - 990 - 700
21
6.35/9.52
5/15/35/50

10.0 - 12.5 - 15.0


30 - 34 - 37
0.63
200 - 990 - 700
23
6.35/12.7
5/15/35/50

12.0 - 15.0 - 18.0


30 - 34 - 38
0.63
200 - 1190 - 700
27
6.35/15.88
5/15/35/50

12.0 - 16.0 - 20.0


30 - 35 - 40
0.84
200 - 1190 - 700
27
9.52/15.88
5/15/35/50

32

Indoor Unit Compatibility Table


Possible combinations of outdoor units and indoor units are shown below.
Outdoor Unit
Indoor Unit
MSZ-EF25VE

Wall-mounted

MSZ-EF35VE

MSZ-EF50VE
MSZ-EF

MSZ-GE25VA

MSZ-GE35VA
MSZ-GE(25/35/50)

MSZ-GE50VA

MSZ-GE60VA
MSZ-GE(60/71)

MSZ-GE71VA

1-way cassette

MLZ-KA25VA

MLZ-KA35VA

MLZ Series

4-way cassette

MLZ-KA50VA

PLA-RP50BA

PLA-RP60BA

PLA Series

Ceiling-concealed

PLA-RP71BA

SEZ-KD25VAL

SEZ-KD35VAL

SEZ-KD50VAL

SEZ Series

SEZ-KD60VAL

SEZ-KD71VAL

33

MXZ2C52VA

3C68VA

4C71VA

4C80VA

5C100VA

6C120VA

External Dimensions
Wall-Mounted
MSY-EF10VA MSY-EF13VA MSY-EF18VA
MSZ-EF25VE MSZ-EF35VE MSZ-EF50VE

Unit : mm

MSY-GE10VA MSY-GE13VA MSY-GE18VA


MSZ-GE25VA MSZ-GE35VA MSZ-GE50VA
INDOOR UNIT

INDOOR UNIT
895
875

798
785

10

6.5

Air in
Installation plate

Air in
232

299

Piping

Air out

50

619

42

130

Drain hose

107

Air out

112

19

159

58

56
69

18

193

60

Drain hose

94
110

(80)

100

158

295

678

58

Piping

47

100

59

Installation plate

MSY-GE24VA MSY-GE26VA MSZ-GE60VA MSZ-GE71VA


INDOOR UNIT

1100
1090

238
Air in
Installation plate
Piping

843

181

Air out

125
160
184

Drain hose

18

193

60

65
( 70 )

76

100

12

67

325

34

Light weight

By the entrance

Easy to transport and


install at site.

On the balcony

Light and easy to carry


Welc
om

Easy to transport by elevator

SERIES

Flexible choice and suitable for


the limited outdoor space.

Smaller footprint
8HP

New S series

8HP
Extended residence space.

Advanced
Energy-saving
Technologies

S series

PUMY-P VKM
PUMY-P YKM

Highly efficient fan and grille for outdoor unit


The shapes of the fan and grille of the outdoor unit have been redesigned, realising an increase in blowing capacity and more efficient heat
exchange while maintaining the same operating noise level.

Outdoor unit fan opening increased


4HP x 2units

8HP x 1units

New S series can maximize


residential area.

The two-pipe zoned system designed for Heat


Pump Operation
The CITY MULTI S series make use of a two-pipe refrigerant system, which allows for system changeover from cooling to
heating, ensuring that a constant indoor climate is maintained in all zones. The compact outdoor unit utilizes R410A refrigerant and an INVERTER-driven compressor to use energy effectively.
With a wide range of indoor unit line-up in connection with a flexible piping system, the CITY MULTI series can be configured
for all applications. Up to 12 indoor units can be connected with up to 130% connected capacity to maximize engineer's
design options. This feature allows easy air conditioning in each area with convenient individual controllers.

The diameter of the opening for the fan in the outdoor unit has been increased from 490 to 550mm. Blowing capacity has been increased
while maintaining the same fan rotation speed.

Opening increased
from 490 to 550mm
in diameter

Grille shape changed

Inflexed fan

The shape of the air


outlet grille has been
c h a n g e d to r e d u c e
pressure l o s s. T h i s
has helped to improve
heat exchange performance.

Adoption of a fan with improved ventilation characteristics and a newly designed rear edge that suppresses
wind turbulence raises fan operation efficiency.

PUMY-P V/YHMB

Fan rear edge

PUMY-P V/YKM

Highly efficient heat exchanger


A high density and increase in surface area have improved the heat-exchange efficiency
of the heat exchanger.
Outdoor unit

[P112~140(V/YKM)]

Residence

Refrigerant Piping Lengths

Maximum meters

Total length
Maximum allowable length
Farthest indoor from first branch

300
150 (175 equivalent)
30

Vertical differentials between units

Maximum meters

Indoor/outdoor (outdoor higher)


Indoor/outdoor (outdoor lower)
Indoor/indoor

50
40
15

Furthest piping length


175m
(equivalent length)
(actual length 150m)

Top-bottom
differential
50m

Between indoor units


top-bottom differential
15m

High-density heat exchanger

Outdoor unit

Outdoor unit

Silent mode can reduce sound


pressure level by 3dB(A)

Maximum meters

Total length
Maximum allowable length
Farthest indoor from first branch

150
80 (90 equivalent)
30

Vertical differentials between units

Maximum meters

Indoor/outdoor (outdoor higher)


Indoor/outdoor (outdoor lower)
Indoor/indoor

50
40
15

Furthest piping length


90m
(equivalent length)
(actual length 80m)

Top-bottom
differential
50m

Between indoor units


top-bottom differential
15m

Indoor unit

Heat exchanger

A HIC circuit has been added to improve energy efficiency during cooling operation. Liquid refrigerant is
rerouted, transformed into a gas state and injected
back into the system to increase overall pressure of
the refrigerant being sent to the compressor, thereby
reducing the load on the compressor and raising efficiency.

Heat exchanger

PUMY-P V/YHMB

Heat
Interchanger
(HIC)

PUMY-P V/YKM

Cooling operation

Indoor
HEX

Outdoor
HEX

Accumulator
LEV B

Compressor

LEV C

LEV A
Heat
interchanger(HIC)

w/ HIC circuit
w/o HIC circuit
I_current
I_new

43

Increase in heat-exchanger surface area

(image)

Heat-exchange surface area increased


Heat exchanger size extended horizontally, increasing the
surface area.

Indoor unit

[P175~225(YKM)]

2 lines, 64 columns

The pipe diameter has been changed from 9.52 to 7.94mm, resulting
in a high-density heat exchanger.

Heat Interchanger (HIC) Added


Refrigerant Piping Lengths

2 lines, 52 columns

HIC without to increase the heat


exchange volume with increasing

I.

44

Advanced
Energy-saving
Technologies

System Controller

OUTDOOR UNIT S Series


Specifications

MITSUBISHI ELECTRIC's Air-conditioner Network System (MELANS) leads air conditioner management a PC
browser and Network era.

Model

Power source

Cooling capacity
(Nominal)

12.5

14.0

15.5

12.5

14.0

42,700

47,800

52,900

42,700

47,800
3.46
5.53-5.26-5.07

Indoor temp.

8HP
Extended residence space.

4.46-4.24-4.09

3.43

4.48

4.05

W.B.

15.0~24.0C

15.0~24.0C

15.0~24.0C

15.0~24.0C

15.0~24.0C
-5.0~46.0C

D.B.

-5.0~46.0C

-5.0~46.0C

-5.0~46.0C

-5.0~46.0C

kW

14.0

16.0

18.0

14.0

16.0

*2

BTU / h

47,800

54,600

61,400

47,800

54,600
3.74
5.98-5.68-5.48

Power input

kW

3.04

3.74

4.47

3.04

Current input

14.03-13.42-12.86

17.26-16.51-15.82

20.63-19.73-18.91

4.86-4.62-4.45

4.61

4.28

4.03

4.61

D.B.

15.0~27.0C

15.0~27.0C

15.0~27.0C

15.0~27.0C

Outdoor temp.

W.B.

Indoor unit
connectable

Total capacity

-20.0~15.0C

-20.0~15.0C

-20.0~15.0C

-20.0~15.0C

50~130 % of outdoor unit capacity

50~130 % of outdoor unit capacity

50~130 % of outdoor unit capacity

50~130 % of outdoor unit capacity

P15~P140 / 9

P15~P140 / 10

P15~P140 / 12

P15~P140 / 9

P15~P140 / 10

49 / 51

50 / 52

51 / 53

49 / 51

50 / 52

9.52 Flare

9.52 Flare

15.88 Flare

15.88 Flare

Model / Quantity
dB <A>

Highly efficient
fan
outdoor unit
15.88
Flare and grille for
15.88 Flare
15.88 Flare
mm

Refrigerant piping
diameter

Liquid pipe

FAN

Air flow rate

New S series can maximize


residential area.

9.52 Flare

9.52 Flare

9.52 Flare

m3 /min

110

110

110

110

110

L/s

1,833

1,833

1,833

1,833

1,833

Gas pipe

kg

Power source

123

123

The two-pipe zoned system designed for Heat


Pump Operation

Heating capacity
(Nominal)

The CITY MULTI S series make use of a two-pipe refrigerant system, which allows for system changeover from cooling to
heating, ensuring that a constant indoor climate is maintained in all zones. The compact outdoor unit utilizes R410A refrigerant and an INVERTER-driven compressor to use energy effectively.
With a wide range of indoor unit line-up in connection with a flexible piping system, the CITY MULTI series can be configured
for all applications. Up to 12 indoor units can be connected with up to 130% connected capacity to maximize engineer's
design options. This feature allows easy air conditioning in each area with convenient individual controllers.

Temp. range of
heating
Indoor unit
connectable

R410A 4.8kg

125

125

Outdoor unit

[P112~140(V/YKM)]
Refrigerant Piping Lengths

Maximum meters

Total length
Maximum allowable length
Farthest indoor from first branch

300
150 (175 equivalent)
30

Vertical differentials between units

Maximum meters

Indoor/outdoor (outdoor higher)


Indoor/outdoor (outdoor lower)
Indoor/indoor

50
40
15

Furthest piping length


175m
(equivalent length)
(actual length 150m)

Top-bottom
differential
50m

Between indoor units


top-bottom differential
15m

6.91

9.62

11.29-10.72-10.34

15.72-14.93-14.39

3.65

3.24

2.60

Indoor temp.

W.B.

15.0~24.0C

15.0~24.0C

15.0~24.0C

15.0~24.0C

-5.0~46.0C

-5.0~46.0C

FAN

Air flow rate

Gas pipe

22.4
5.73
9.36-8.89-8.57

11.37-10.80-10.41

3.91

3.59

3.57

15.0~27.0C

15.0~27.0C

15.0~27.0C

-20.0~15.0C

-20.0~15.0C

50~130 % of outdoor unit capacity

50~130 % of outdoor unit capacity

P15~P224 / 12

P15~P250 / 12

P15~P250 / 12

56/ 61
PUMY-P
V/YKM

9.52 Flare *3

9.52 Flare *3

mm

15.88 Flare

22.2 Brazed

22.2 Brazed

22.2 Brazed

m3 /min

110

134

134

143.8

2,233

2,397

L/s
1,833
2,233
Highly
efficient
heat exchanger
cfm

3,884

4,732

4,732

5,078

1,338 x 1,050 x 330 (+25)

1,338 x 1,050 x 330 (+25)

1,338 x 1,050 x 330 (+25)

1,338 x 1,050 x 330 (+25)

High-density heat exchanger

Indoor unit

7.5m

0m

2 lines, 52 columns

ExternalTheDimensions
pipe diameter has been changed from 9.52 to 7.94mm, resulting

Unit : mm

2 lines, 64 columns

PUMY-P112V(Y)KM
PUMY-P125V(Y)KM
PUMY-P140V(Y)KM
in a high-density
heat exchanger.
PUMY-P175YKM
PUMY-P200YKM
PUMY-P225YKM

Increase in heat-exchanger surface area

(image)

Heat-exchange
surface area increased
OUTDOOR
UNIT
1050

Between indoor units


top-bottom differential
15m

7C DB/6C WB

Level difference

A high density and increase in surface area have improved the heat-exchange efficiency
Type x original charge
R410A 4.8kg
R410A 7.3kg
R410A 7.3kg
R410A 7.3kg
of the heat exchanger.
kg
125
138
138
138

600

362

Terminal connection
From left to right

Heat exchanger
For the *1
branch box
power supply

For the
power supply

Ground for the power supply


("GR"marking position)

For the
transmission line

Heat exchanger

For concentration
control

PUMY-P V/YHMB

225

19

PUMY-P V/YKM

Ground for the transmission line


Ground for concentration control

417

370

330

Maximum meters
50
40
15

20C DB

Pipe length

Fan rear edge

mm

56
33
0
53

70(75*)

632

56(60*)

1338

28

42

25

Vertical differentials between units


Indoor/outdoor (outdoor higher)
Indoor/outdoor (outdoor lower)
Indoor/indoor

58 / 63

9.52 Flare *3

2-U Shaped notched holes


(Foundation Bolt M10)

Handle for
moving

Air Discharge
A HIC circuit
has been added to improve energy efficiency during cooling operation. Liquid refrigerant is
PUMY-P175/200/225YKM
rerouted, *transformed
into a gas state and injected
back into the system to increase overall pressure of
the refrigerant being sent to the compressor, thereby
reducing the load on the compressor and raising efficiency.

1 Refrigerant GAS pipe connection


PUMY-P112/125/140V(Y)KM:(Flare) 15.88

Ground for *1
the branch box

power supply
Heat
Interchanger
Service panel
(HIC)

Cooling operation
PUMY-P175/200/225YKM:(attached JOINT) 22.2

2 Refrigerant LIQUID pipe connection


:(Flare) 9.52

Handle for
moving

Air Intake

Indoor
HEX

LEV B

1
2

*1 PUMY-P112/125/140V(Y)KM only.
Outdoor
Accumulator
*2 Indication
of STOP VALVE connection
location.
HEX
*3 PUMY-P175/200/225YKM:(Flare) 19.05(3/4F)

Compressor

Model

PUMY-P112/125/140VKM

LEV1062
A
Heat
interchanger(HIC)
PUMY-P112/125/140YKM
909

26

2-1236 Oval holes


(Foundation Bolt M10)

369

Furthest piping length


90m
(equivalent length)
(actual length 80m)

Top-bottom
differential
50m

56 / 61

9.52 Flare

Heat Interchanger (HIC) Added

150
80 (90 equivalent)
30

35C DB

*3 Liquid pipe diameter:12.7mm in case of farthest


piping length is longer than 60m.

-20.0~15.0C

mm

Installation Feet

Total length
Maximum allowable length
Farthest indoor from first branch

12.50-11.87-11.44

50~130 % of outdoor unit capacity

Side Air Intake

Maximum meters

Cooling

Outdoor

Adoption of a fan-5.0~46.0C
with improved ventilation
characterisHeating
7.5m
0m
25.0
27.3
tics and a newly designed
rear *Nominal
edgecondition
that*1,*2suppresses
85,300
93,200
are subject to ISO 15042.
6.96
7.65 fan operation
*Due to continuing
improvement, above specification
wind turbulence raises
efficiency.
may be subject to change without notice.

76,400

51 / 53
PUMY-P
V/YHMB

dB <A>

Inflexed fan

*1,*2 Nominal conditions

Indoor
Opening increased
fromCooling
490 27C
to 550mm
DB/19CWB
in diameter
Heating

5.48
8.95-8.51-8.20

225

Refrigerant Piping Lengths

85,300

4.52

Heat exchanger size extended horizontally, increasing the


Rear Air Intake
surface area.

Outdoor unit

25.0

7.23-6.87-6.62

Liquid pipe

Indoor unit

[P175~225(YKM)]

3-phase 380-415V 50Hz

Outdoor temp.
The
shape of D.B.
the air -5.0~46.0C
18.0
*2
kW
outlet grille*2has
61,400
BTU /been
h
4.47
c h Power
a n ginput
e d to r ekWd u c e
7.15-6.79-6.55
Current input
A
pressure
l o skWs./ kWT h i s
4.03
COP
15.0~27.0C
temp. to improve
D.B.
hasIndoor
helped
-20.0~15.0C
Outdoor temp.
heat
exchange W.B.
perfor50~130 % of outdoor unit capacity
Total capacity
mance.
P15~P140 / 12
Model / Quantity

Notes:

PUMY-P225YKM

kW

Refrigerant piping
diameter

Refrigerant

LEV C

Front piping cover


Rear piping cover

w/ HIC circuit
w/o HIC circuit

I_current
I_new

45

R410A 4.8kg

123

Current input

Sound pressure level


(measured in anechoic room)

Net weight

Silent mode can reduce sound


pressure level by 3dB(A)

3,884
1,338 x 1,050 x 330 (+25)

Power input

External dimension HxWxD

Outdoor unit

3,884
1,338 x 1,050 x 330 (+25)

PUMY-P140YKM
PUMY-P200YKM
The diameter of the opening
for the fan in thePUMY-P175YKM
outdoor unit has been
in380-415VBlowing
50Hz
3-phase 380-415V
3-phase 380-415V 50Hz
creased from 490 to 3-phase
550mm.
capacity
has50Hz
been increased
15.5
20.0
22.4
*1
kW
while maintaining
the same52,900
fan rotation speed. 68,200
*1 BTU / h
76,400

Grille
shape
changed
3.43
EER
kW / kW
Temp. range of
cooling

-20.0~15.0C

mm

The shapes ofcfm


the fan and3,884
grille of the outdoor
unit have been rede3,884
3,884
External dimension HxWxD
signed, realising
an increase
in blowing capacity
and more efficient
heat
mm
1,338 x 1,050 x 330 (+25)
1,338 x 1,050 x 330 (+25)
1,338 x 1,050 x 330 (+25)
exchange
while maintaining
the same operating
noise level.
Refrigerant
Type x original charge
R410A 4.8kg
R410A 4.8kg
R410A 4.8kg

Cooling capacity
(Nominal)

PUMY-P
VKM
4.28
15.0~27.0C
PUMY-P
YKM

50~130 % of outdoor unit capacity

Outdoor unit fan opening increased


8HP x 1units

S series

kW / kW

Indoor temp.

Net weight

4HP x 2units

Residence

20.86-19.95-19.12

4.05

Temp. range of
heating

Model

15.97-15.27-14.64

4.48

Welc
om

New S series

4.52

12.87-12.32-11.80

B *2

Light and easy to carry

8HP

3.46

kW / kW

C *2*3

On the balcony

Easy to transport by elevator

By the entrance

Smaller footprint

2.79

2.79

kW

*2

Outdoor temp.

Sound pressure level


(measured in anechoic room)

Light weight

PUMY-P125YKM
3-phase 380-415V 50Hz

kW

COP

Flexible choice and suitable for


the limited outdoor space.

PUMY-P112YKM
3-phase 380-415V 50Hz

BTU / h

Current input

Easy to transport and


install at site.

PUMY-P140VKM

1-phase 220-240V 50Hz

*1

EER

Heating capacity
(Nominal)

PUMY-P125VKM

1-phase 220-240V 50Hz

*1

Power input

Temp. range of
cooling

PUMY-P112VKM

1-phase 220-240V 50Hz

PUMY-P175/200/225YKM

HIC without to increase the heat


exchange volume with increasing

986

510

426

510

426

450

393

I.

46

Wide Selection of Indoor Units


Model name

Ceiling
Cassette

4-way air flow

Model name

Model

P15

P20

P25

P32

P40

P50

P63

P71

P80

P100

P125

P140

P200

P250

PLFY-P VBM-E

PLFY-P VCM-E2

2-way air flow

PLFY-P VLMD-E

1-way air flow

PMFY-P VBM-E

Ceiling Concealed

PEFY-P VMR-E-L/R

PEFY-P VMS1(L)-E

PEFY-P VMA(L)-E

PEFY-P VMA3-E

PEFY-P VMH(S)-E

Fresh Air
Intake

PEFY-P VMH-E-F

Ceiling
Suspended

PCFY-P VKM-E

Wall Mounted

PKFY-P VBM-E

PKFY-P VHM-E

PKFY-P VKM-E

Floor Standing/
Floor Mounted
Concealed

PFFY-P VKM-E2

PFFY-P VLEM-E

PFFY-P VLRM-E
PFFY-P VLRMM-E

47

48

System
SystemController
Controller

The
System
New Structure
Cooling-only Models

Mitsubishi
MITSUBISHI
Electric's
ELECTRIC's
Air-conditioner
Air-conditioner
NetworkNetwork
System (MELANS)
System (MELANS)
introduces
leads
an era
airofconditioner
air conditioner
management
management
a PC
via
browser
PC browsers
and Network
connected
era.
to a Network.

Mitsubishi
In an easyElectric
and flexible
offersmanner
a wide with
lineup
our
ofnew
newCentralized
cooling-only
Controller
models with
AE-200E,
themaximum
an optimum
capacity
system
of 54
canHP*.
be Different
patterns
established
of combinations
according toof
the
basic
scale
modules
of facilities.
provide either standard or high COP.
*Applicable to standard model combinations only

MELANS
MELANS

Requires
joint work

Single module up 20 HP

Use
Useofofour
ourMELANS
MELANSproducts
productsenhances
enhancesEFFICIENCY
EFFICIENCYand
andQUALITY
QUALITYofofair-conditioning,
air-conditioning,contributing
contributingtotoENERGY
ENERGYSAVING
SAVINGand
and
reduction
reduction
inin
running
running
cost.
cost.
We
We
offer
offer
a wide
a wide
variety
variety
ofof
MELANS
MELANS
products
products
toto
meet
meet
allall
requirements
requirements
- from
- from
the
the
smallest
smallest
and
and
simplest
simplest
toto
the
thelargest
largestand
andmost
mostcomplex.
complex.
We
Wehave
haveindividual
individualremote
remotecontrollers,
controllers,various
variouscentralized
centralizedcontrollers,
controllers,and
andcentralized
centralizedintegrated
integratedsoftware,
software,asaswell
wellasasBMS
BMS
interface
interface
hardware
hardwareand
andsoftware
softwareetc.
etc.Above
Aboveall,all,with
withAE-200E/AE-50E/AG-150A/EB-50GU-J/GB-50ADA-J,
AE-200E/AE-50E/AG-150A/EB-50GU-J/GB-50ADA-J,PC
PCbrowser
browserand
andlong
longdistance
distance
remote
remotecontrol
control(monitoring
(monitoringand
andoperating)
operating)viaviacommunication
communicationNetwork
Networkis ispossible
possibleand
andeasy.
easy.

ndividual Remote Controller

Remote
Controller

Simple
Remote
Controller

Wireless Remote
Controller

C entralized Remote Controller


Advanced
Touch
Controller

Field-installed

HUB
BACnet

NEW

AE-200E/AE-50E

Field-installed

Tablet

All modules feature inverter-driven compressors.


Maximum combined horse power: 60 HP

52C

New

Current

M-NET

M-NET

LAN1

AG-150A

group 1

AT-50B

ON/OFF
Remote
Controller

M-NET
M-NET

Capable of running cooling operations


HUB of up to
HUBtemperature
in the outdoor
52C*.
LAN2
*Compared to 46C of the older model

NEW

20HP

No need for
joint work

PC

*1

All of the local remote controllers feature liquid


crystal and LED displays and easy to operate.

10HP

Capable
of management
covering up
to 20 HP with a single module and a single
Building
system
BMS
compressor.
Reduced piping work.

To be connectable with
Compatibility
to outdoor temperature
BACnet
Router
of up to 52C*1

10HP

group 2

AE-200E
EB-50GU-J

PAC-YG50ECA

PAR-31MAAE

M-NET

Increase in the limit of piping length


LAN1 : For air conditioning systems
LAN2 : For BACnet

PAC-YT52CRA
PAR-FL32MA PAR-FA32MA

GB-50ADA-J
PAC-YT40ANRA

Farthest indoor from first branch: 90 m Height difference


between indoor and indoor units is up to 30 m.

group 3

AHC ADAPTER

PAR-U02MEDA

First Branch
*1

PAR-SA9FA-E

PAR-SL94B-E

group 4

PAC-IF01AHC-J

PI Controller

Power supply unit


(PAC-SC51KUA)

Max height

30m

*2

General Equipment
DIDO Controller (PAC-YG66DCA)

Max length

90m*3

Temp/Humidity sensor

Lights

Ventilation

Security card reader

AI Controller (PAC-YG63MCA)

PAC-YG60MCA

OUTDOOR UNIT
S : PUMY
Y : PUCY/PUHY

DIDO Controller

INDOOR UNIT
PLFY
PMFY
PEFY

PCFY
PKFY
PFFY

PAC-YG66DCA

AI Controller

Watt hour meter

Standard or high COP options are available


by different combinations
of modules.
LAN2

PI Controller (PAC-YG60MCA)

LAN1

Farthest indoor from first branch: 90 m Height difference


AE-50E
between indoor and indoor units is up to 30 m.
PAC-YG63MCA

Interface

Interface

LAN2

*1. Advanced HVAC CONTROLLER

LLAN1

XL
AE-50E

BAC-HD150

A ir-Conditioning

LMAP04-E

LAN2

Control System

BACnet *1

transmission line
(Ethernet)

This is a specialized air conditioning management system, in which


up to 2000 indoor units can be
centrally controlled.

LONWORKS *2

transmission line

Mitsubishi Electric's
CITY MULTI can be easily
connected to the building
management system through
BACnet .

LAN1

HP
example : 30HP

8 10 12

COP

Integrated centralized
control software
TG-2000A

COP

3.33

3.88

Standard
model

HighCOP
model

12

Ethernet

AE-50E
20

14 16 18

18

30

*1. Please contact your local distributor for when the feature is supported.

14

30

Integrated centralized
control software TG-2000A

49

*Some controllers cannot be used in combination with certain models of devices.


*1 BACnet is a registered trademark of ASHRAE.
*2 LonWorks is a trademark of Echelon Corporation registered in the United States and other countries.

*1 : Any continuous operation over 46C may require an increased frequency of maintenance.
*2 : When the height difference is 15m or greater, use the one size larger liquid pipe between the indoor unit and the indoor unit.
*3 : When the piping length is 40m or longer, use the one size larger liquid pipe between the indoor unit and the first branch.
50

1-way cassette

Unit : mm

MLZ-KA25VA MLZ-KA35VA MLZ-KA50VA


INDOOR UNIT
(Top)

35

466.5

0
10

20~45
860~910

605 +35
-5

74

241 258

85 77

20~45

Detail connecting of branch duct


90

100

Cut out hole

90

Power supply wire,


Indoor unit/Outdoor unit
connecting wire entry

Ceiling
Grille

155

Keep approximately
10 to 15mm space
between unit ceiling
and ceiling slab.

175

Burring hole pitch

350

150

167

70

Control wire entry

35

Suspension bolt
lower edge

100

130

Drain pipe

100

377

Hole position for the


installation of grille

284

17 +50

R6

466.5

166.5
173

60

Refrigerant pipe
(gas)
170

160

105

CL

414

81.8

PLA-RP60BA

840

Suspension bolt
M10 or W3/8

50~70

R6

80

PLA-RP71BA

Refrigerant pipe
(liquid)

172.4
166.5

(7.5)

Ceiling surface

24

Grille

160

Ceiling surface

140

CL

PLA-RP50BA

190

34

1200

Receiving section

Models

Branch duct hole

87

187.5

Grille (MLP-440W)

Suspension bolt pitch

Suspension bolt M10

Ceiling hole

(7.5)

160
840

Indoor power supply


terminal block(optional part)

Ceiling
surface
Display and
receiving section

(Front)

Remote controller
terminal block
Indoor unit/Outdoor
unit connecting
terminal block

156

58 No gaps between
the ceiling surface and grille

0.04m2

Branch duct hole


950

112
60

25

48

Gas pipe
Liquid pipe

31

110

116
Pipe cover
Drain pan

Outlet opening area

20

110
Drain pipe

Electrical box

54.5

90

78

Suspension bolt pitch

175

170

180 or more

960

1160 Ceiling opening

244

Drain hose

160

Outlet

1051 Suspension bolt pitch

360

175

1102

Air outlet

1200 Outer side of grille

(Right side)
Drain hose

20~45

860~910
810

620

38

15

54.5
20

(Front)

Ceiling hole

20~45

Fresh air
intake hole

150

20

950
Center of ceiling opening,
suspension bolt pitch and grille
are located in one position.

308 Suspension bolt pitch

158

15

180

230
15

1051 Suspension bolt pitch

18

26

Drain hose
connecting part

Air outlet

58

414 Outer side of grille

26

Pipe
cover

Electrical box

20

308
Suspension bolt pitch

2
2

Wireless
remote controller

384 Ceiling opening

Center of ceiling opening, suspension bolt pitch


and grille are located in one position.

38

13.5

58

49.7

Unit : mm

PLA-RP50BA PLA-RP60BA PLA-RP71BA


INDOOR UNIT

(Top)

(51.6)

4 -way cassette

14- 2.8

Burring hole

Cut out hole

36

Ceiling-concealed

Unit : mm

SEZ-KD25VAL SEZ-KD35VAL SEZ-KD50VAL SEZ-KD60VAL SEZ-KD71VAL

OUTDOOR UNIT

37
400

169

Drain hole

63.2

Air in

18.3

344.5

16.8

171

288

12.3

Air in

Air out

Air out

Drain holes

2-10x21 Oval hole


22.3

23

285

17.7

H
100XJ=K

Air
inlet

500
233.1

40

Air
outlet

B (Suspension bolt pitch)

D (Duct)

100X(E-1)=F

17.5

Air in

304 325

44

88

Air in

396

37 100

OUTDOOR UNIT

17.7

12

15

157.5

MXY-3A28VA MXZ-3C68VA

360.6
(Bolt Pitch)

20

Unit : mm

MXY-2E20VA MXZ-2C52VA

31.3

INDOOR UNIT

MXY SERIES MXZ SERIES

4-10 x 21 Oval hole


(Base bolt M10)

13

840

30

200

30

330

13

240

66.3

170.4

800

69

440

C unit connection

500

225

150

Gas pipe

710

251.1

302.5

Knockout hole 27
(Indoor/outdoor connecting line)

Control box

B unit connection
A unit connection

299

Notes:

700

20

900

24

MXY-4A28VA MXZ-4C71VA

MXY-4A38VA MXZ-4C80VA MXZ-5C100VA

OUTDOOR UNIT

OUTDOOR UNIT

169

500
233.1

31.3

200

171

288

35

Air in

18.3

16.8

63.2

12.3

Air in
Drain holes

500

Air in

Air out

Air in
Drain holes

4-10 x 21 Oval hole


(Base bolt M10)

30

30

27.1
Indoor and outdoor
connect wiring
39 x 27 hole

2-12 x 36 Oval hole


(Base bolt M10)

30

330

13

Handle

Handle

84

Gas pipe

132
317

10

88

B unit connection
A unit connection

299

45

C unit connection

440

45

360

315

710

D unit connection

460

Gas pipe

320

Indoor and
outdoor
connect
wiring
(35 x 53) hole

66.3

405

200

2 U-shaped notched hole


(Base bolt M10)

900

240

840

200

270

17.7

Air out

250

900

860

(Bolt pitch)
387

800

1000 1060

597

9
11

1. Use M10 bolts for suspension (purchase locally).


2. Keep service space for maintenance at the bottom.
3. This chart is based on the SEZ-KD50VAL, which has three fans.
SEZ-KD25VAL and SEZ-KD35VAL have two fans,
and SEZ-KD60VAL and SEZ-KD71VAL have four fans.
4. If an inlet duct is used, remove the air filter supplied with the unit,
and install a locally purchased filter on the suction side.

16

L
16

11

K
500

355

860

J
5

24

998

H
660

16

952

F
600

27

900

1100 1152 1198 1060

E
7

40

D
660

35

C
798

74

B
752

396

A
700

17.7

Drain pipe(Spontaneous draining)

Model
SEZ-KD25VAL
SEZ-KD35VAL
SEZ-KD50VAL
SEZ-KD60VAL
SEZ-KD71VAL

Liquid pipe

23.1

200

Terminal block
Terminal block (Indoor/outdoor connecting line)
(Remote controller transmission line)

70
270

360.6
(Bolt Pitch)

116

170

102

2X2- 2.9
Refrigerant piping
flare connection (gas)

Knockout hole 27
(Remote controller transmission line)

Indoor and outdoor


connect wiring
39 x 27 hole

A unit
connection

45

Air filter

27.1

B unit
connection

84

23
10

100

150 (Duct)

23
25

Refrigerant piping
flare connection (liquid)

700
677

51 51 51

L- 2.9

Suspension bolt hole


4-14X30 Slot

Liquid pipe
Gas pipe
Liquid pipe
Gas pipe

360

625 (Suspension bolt pitch)

49

10

23

10

280

20
12

57

2XE- 2.9

90

25

20
30

88

550

100

100

handle

E unit connection
(MXZ-5C100VA)
D unit connection
C unit connection
B unit connection
A unit connection

23
Liquid pipe

23.1
Liquid pipe

37

38

Piping Installation
MXZ-6C120VA

MXY SERIES MXZ SERIES

OUTDOOR UNIT

MXY-2E20VA MXZ-2C52VA

Unit : mm

Maximum Piping Length


450

200

(Foundation Bolt M10)

16

42 Drain Hole

Air
Discharge

Outdoor unit - Indoor unit (a,b)

20m

Total length (a+b)

30m

Maximum height
difference

Outdoor
unit

Maximum Number of Bends

40

24

Side Air Intake

387

355
(Bolt Pitch)

11

48

Rear Air
Intake

2-U Shaped Notched Hole

27

500

16

200

Indoor
units

2-12 x 36 Oval Hole

Outdoor unit - Indoor unit (a,b)

20

Total number (a+b)

30

Outdoor unit
|

Indoor unit

15m

*Outdoor unit
installed lower

21

320

15m

(Foundation Bolt M10)

900

Indoor unit
Indoor unit

Outdoor unit
|

Indoor unit

b
Connecting
Wire Hole
(36 x 96)

10m

*Outdoor unit
installed higher

Handle
70

515

LIQ
GAS
LIQ
GAS
LIQ
GAS
LIQ
GAS
LIQ
GAS
LIQ
GAS

Unit F
Unit E
Unit D
Unit C

LIQ 6.35(1/4")FLARE
GAS 9.52(3/8")FLARE

Unit B
Unit A

LIQ 6.35(1/4")FLARE
GAS 12.7(1/2")FLARE

125

45

548

730

65

1070

Handle

340

34

MXY-3A28VA MXZ-3C68VA

Indoor
units

Maximum Piping Length


Outdoor unit - Indoor unit (a,b,c)

25m

Total length (a+b+c)

60m

Highest

Outdoor
unit

Maximum Number of Bends


Outdoor unit - Indoor unit (a,b,c)

25

Total number (a+b+c)

60

Maximum height
difference

Outdoor unit
|

Indoor unit

15m

*Outdoor unit
installed lower
Indoor unit
|

Indoor unit

15m

Lowest

Outdoor unit

Indoor unit

10m

*Outdoor unit
installed higher

39

40

MXY-4A28VA MXZ-4C71VA

Indoor
units

Maximum Piping Length


Outdoor unit - Indoor unit (a,b,c,d)

25m

Total length (a+b+c+d)

60m

Highest

Outdoor
unit

Maximum Number of Bends


Outdoor unit - Indoor unit (a,b,c,d)

25

Total number (a+b+c+d)

60

Maximum height
difference

Outdoor unit
|

Indoor unit

15m

*Outdoor unit
installed lower Indoor unit
|

MXY-4A38VA MXZ-4C80VA

Indoor unit

15m

Lowest

Maximum Piping Length


Outdoor unit - Indoor unit (a,b,c,d)

25m

Total length (a+b+c+d)

70m

Outdoor unit

Indoor unit

10m

*Outdoor unit
installed higher

Maximum Number of Bends


Outdoor unit - Indoor unit (a,b,c,d)

25

Total number (a+b+c+d)

70

Indoor
units

MXZ-5C100VA

Maximum Piping Length


Outdoor unit - Indoor unit (a,b,c,d,e)

25m

Total length (a+b+c+d+e)

80m

Highest

Maximum height
difference

a
Outdoor
unit

Outdoor unit
|

Indoor unit

Maximum Number of Bends

15m

Outdoor unit - Indoor unit (a,b,c,d,e)

25

Total number (a+b+c+d+e)

80

*Outdoor unit
installed lower Indoor unit
|

Indoor unit

15m

Outdoor unit
|

Lowest

Indoor unit

10m

d e

*Outdoor unit
installed higher

Highest
Indoor
units

MXZ-6C120VA

Maximum Piping Length


Outdoor unit - Indoor unit (a,b,c,d,e,f)

25m

Total length (a+b+c+d+e+f)

80m

Maximum height
difference

a
Outdoor
unit

Outdoor unit
|

Indoor unit

Maximum Number of Bends

15m

Outdoor unit - Indoor unit (a,b,c,d,e,f)

25

Total number (a+b+c+d+e+f)

80

*Outdoor unit
installed lower Indoor unit
|

Indoor unit

15m

Outdoor unit
|

Lowest

Indoor unit

d f

41

10m

*Outdoor unit
installed higher

42