You are on page 1of 44

GenXT

NextGenerationImplantology

Product Catalogue
2014

GenXT
Published by TRATE. We reserve the right to make amendments without notice. All rights reserved.
No information published in this catalogue may be used the written agreement of TRATE, Switzerland.
Questions, comments, and requests can be sent by e-mail to support:GenXT.ch. Website address: www.GenXT.ch.
This catalogue, "GenXT 2014", is valide from 1 January 2014 untill the publication of the next catalogue.
Note: For the purpose of legibility, TRATE does not use or in the text.
This does not affect TRATE's rights with regard to registered trademarks.
Disclaimer: some products may not be available in all markets. Please contact your local TRATE representative
to review the product range available. Images of devices in this catalogue may differ from the actual devices.

GenXT
NextGenerationImplantology

Dental Implant Systems

Contents
2

About GenXT Dental Implants

Support, Service and sales

System Selection Indicators

Root Form - 2 Piece Implant System

21

Compressive - 1 Piece Implant System

29

Basal - 1 Piece Implant System

39

Educational Material

GenXT
Next Generation Implantology
iGenXT Dental Implants is a result of our constant interaction with researchers
and leading Implantologists, all focused on creating a treatment modality that
has the patients comfort at its center. Simplicity, ease of placement & resoration,
and predictable long term results our are key goals. With these goals in mind we
have created 3 Implant systems within a single platform that can answer the
needs of your patients.

Evolved from years of collective research


GenXT is the latest system developed with
current advancements in Implant dentistry.
Its not your old implant adapting to new trends,
its innovative bioengineering for the future
of Implantology.

GenXTConcepT
Implantology began with creativity and innovativeness. Somewhere along the
way this was lost, and a monotonous treatment plan was adapted to every patient
This was because of limited understanding of concepts at that time and limitations
in manufacturing. We decided to change that, instead of the doctor and patient
adapting to the limitations of the implant system. We created a system based on
simple biological principles, engineered in a way so that the system adapts to the
doctors innovativeness and patients demands. Ever felt limited by your tools,
GenXT provides with with the tools to excel.

GenXTConcepT

Clinical Viability
Innovative Research
Biologic principles

GenXT

The GenXT system, using the GenXTConcepT, has the advantage


of dispensing with the overcomplicated treatment procedures
recommended by implant manufacturers who are interested in promoting
their products on the market. The principle of the approach
is to create the ideal artificial tooth on a support which integrates
organically with existing biological structures.

Innovations and development


The system is being developed and perfected by independent practitioners
throughout the world, reflecting the collective views of the Open Dental Community.
This approach to development avoids reliance on individual opinions
and means that dentists can select the method most suited to the individual patient.

High quality and safety standards


As a leader in ECRS implantology, we aim to maximise efficiency in the production
and distribution of our products while maintaining high quality and safety standards.
ISO
13485

ISO
9001

Medical devices
Quality
management

Quality
management

The fact that we have our own global distribution network allows us to guarantee
high levels of service.

The company operates a quality management system based on DIN EN ISO


9001:2008 and EN ISO 13485:2010. The company's products are certified in
compliance with the provisions European Directive 93/42/EEC.

GenXT

Support and sales


TRATE provides comprehensive service and support via highly qualified representatives
and offers wide range of training services and a website for specialists, including an online shop.

Online shop - www.Genxtimplantology.com


Products from our entire range are available 24 hours a day from our online shop.
An intuitive interface allows you to find the right product quickly.
Orders are dispatched straight to your clinic or laboratory.

Support
TRATE representatives are on hand to help you with any questions you may have
about the GenXT system. They can also assist you in using our online shop.
You can contact our representatives directly or via the form on the website.

Training
We provide a full range of training services to help clinics and laboratories introduce
the GenXTCONCEPT. An online course is available for everybody, 24 hours a day.
For more detailed information, please visit our website at www.GenXT.ch.

Professional internet resource


Genxtimplantology.com

The resource at www.GenXT.ch has an intuitive and simple interface designed to cover everything
required in daily practice. It also provides a forum for you to exchange information with colleagues.

Guarantee
Al products are guaranteed for ten years. We liaise closely with our clients
and guarantee to replace failed implants, including the superstructures for reintegration.

Patients literature
We care about your relationship with your patients, so we provide free literature for patients.
A complete literature aimed at patients can be found at the end of this catalogue
and at the online shop.

GenXT

Logic of implant selection

ROOTFORM

ROOTFORM

Rootform
implants

GenXT

Improved platform
precision internal hex
single platform for all diameters
reliable bonding with superstructures
convenient set of superstructures

ROOTFORM

Double strength
conical implant body shape
cylindrical thread shape

the space between the cylindrical and conical structures


ensures reliable macrofixation
maximises bone nourishment around the implant body,
decreasing the risk of implant failure both at the early stages
with immediate loading and in the longer term.

Thread structure
decompression groove
the decompression groove not only reduces bone compression,
but also increases the surface area of the intraosseous part
of the implant

Apical part
sharp, deep thread
compact structure
apical self-tapping blades
straight apical platform

the special apical part at the lower third is introduced easily


when screwing into the trabeculae of the compact layer of bone
reliable macrofixation providing primary stability
installation can be performed immediately after dense bone drilling

GenXT

Cervical part
quadruple-start microthread radial structure
treated surface
the microthread in the cervical part means
that the implant couples gently with the compact
hard part of the bone and protects it against breakage

ROOTFORM

the improved radial structure provides


more effective dynamic load distribution

Thread structure
double thread
thread pitch reduces in the apical direction
three-component thread
m-shaped apical part
n-shaped middle part
n-shaped pre-cervical part

gradual thinning ridge with increase in pitch


from the cervical part of the implant
less traumatic insertion
less insertion effort
high primary stability
bone condensation
self-tapping

All these factors contribute towards successful osseointegration


and reliable functioning of orthopaedic constructions
that have been integrated into soft and hard bone using GenXTCONCEPT

GenXT
Two-component root-form screw implant with active thread.
Suitable for single and multiple restorations with immediate and
delayed loading in the upper and lower jaws in all types of bone tissue.
Implant can be placed by flap or flapless approach. Implant placement is
also possible immediately following tooth extraction, as long as

ROOTFORM

sufficient bone tissue is available vertically and horizontally.

Excellent primary stability in all bone types


Microthread in the cervical part
Decompressive groove
Active self-tapping thread

Logic of selection

Reliable implant-abutment bonding

10

GenXT

8 mm

3.8 mm

4.2 mm

5.5 mm

R3808

R4208

R5508

10 mm

R3510

R3810

R4210

R5510

12 mm

R3512

R3812

R4212

R5512

14 mm

R3514

R3814

R4214

R5514

16 mm

R3516

R3816

R4216

R5516

ROOTFORM

3.5 mm

All ROOTFORM
implants are
supplied with a
SC cover screw,
AT2 abutment
with transfer function
and transfer cap
TS
Form drilling
Initial drilling
Use Drills in Sequence till Implant Diameter
Pilot drilling

Check depth
and direction
Implant
positioning
R3810

Drill speed (rpm)

1200-1500

900-1200

200-800
Sequential drilling with form drills of increasing diameter.
If the bone density is insufficient, we recommend reducing
the drill diameter by one step or positioning after pilot drilling.

25-35

11

GenXT

Gingiva former
Anatomical
Should be used in all cases except narrow spaces and

GF1

GF2

1 mm

2 mm

straight abutments with ball attachments. Height is selected


depending on gum biotype. Former shape corresponds
to the gingival part of anatomical and transgingival

ROOTFORM

abutments of the corresponding size.

GF3

GF4

3 mm

4 mm

Narrow
Used where there is insufficient space to place

GFN1

GFN2

1 mm

2 mm

an anatomical abutment and to form the gums


when using straight abutments with ball attachment.

GFN4
4 mm

Preparation of individual
gingival formers
Used to create the required gingival contour in aesthetically
important areas, generally along with surgical correction
of the gum contour. Where necessary, it can be used

GFI

12

as a temporary abutment. Made from biocompatible plastic.


Supplied with S8 fixing screw.

GenXT

Transfers

Transfer, open tray


Should be used in all cases. Supplied with ST transfer screw.
Round marker with 1-mm step for determination of depth
and selection of abutment of corresponding height.

TO

ROOTFORM

WARNING!
Do not use if there is insufficient clinical height for placement
in the distal parts of the upper and lower jaws or if implant axes
diverge by more than 10.

ST

Abutment with Direct transfer Function


Used when there is insufficient clinical height in the distal parts
of the upper and lower jaws and when implant axes diverge by up to 20.
Supplied with SL8 laboratory fixing screw. Round marker with 1-mm step
for determination of depth and selection of abutment of corresponding height.
The innovatory plastic cap fixation system provides an accurate cast
comparable with open tray transfer. The semicircular cutout matches

AT2

TC

the anti-rotation slot and allows several transfer caps to be placed


in a narrow space.

Angled straight transfer


Used when there is insufficient clinical height in the distal parts
of the upper and lower jaws and when the implant axes diverge
by more than 20. Supplied with SL8 laboratory fixing screw.
Round marker with 1-mm step for determination of depth
and selection of abutment of corresponding height. The innovatory
plastic cap fixation system provides an accurate cast comparable

TR17

TC

with open tray transfer. The semicircular cutout matches


the anti-rotation slot and allows several transfer caps to be placed
in a narrow space.

13

GenXT

Implant analogue
Metal analogue
Used for model preparation. The special shape prevents
macro- and micro-mobility during milling, with a minimal internal
diameter, without preventing preparation of split models.

ROOTFORM

AN

Fixing screw
Laboratory
Used at the laboratory stages. Anodised green to avoid
incorrect use during fixation of abutments in the oral cavity.
Supplied with all abutment types.

SL8

Clinical
Used for permanent fixation of abutments in the oral cavity
with a force of 30 Ncm. The structure and material used prevent
unwanted damage to the screw during use.
Supplied with all abutment types in individual pack.

S8

14

GenXT

Abutments
1 mm

2 mm

3 mm

4 mm

Anatomical
Should be used for creating cemented constructions.
The gingival part has been designed on the basis
of detailed analysis of the cervical zone of the natural

Straight

tooth. The anatomical shape of the abutment


significantly reduces the time usually spent milling

ROOTFORM

standard abutments. Supplied with an individually


packed SL8 laboratory fixing screw and S8 clinical
screw.

WARNING!
Do not use for creation of single cemented
constructions in the masticatory area,
in narrow spaces, or for placing implants
at gum level or above.

Angled, 15

Angled, 25

Transgingival
Used for creating of single cemented constructions
in the masticatory area and for preparing

AT1
1 mm

AT2
2 mm

of temporary constructions for immediate


ROOTFORM implant loading. Height adjustment
only. The horizontal limiting marker prevents
the abutment from being shortened by more than
4 mm, ensuring stable fixation. Provided with
BP burnout cap to ensure precise alignment
of the metal body and prevent cementing failure.
Supplied with an individually packed SL8 laboratory
fixing screw and S8 clinical screw.

AT3
3 mm

AT4
4 mm

15

GenXT

Burnout cap
Used for preparation of high-precision metal body for precise alignment
and to prevent cementing failure, which is extremely important when creating
single cemented constructions in the masticatory area.

BP

ROOTFORM

Narrow
Used to create cemented constructions when there is insufficient space
to place an anatomical abutment and when implants are placed at or above
gum level. Supplied with an individually packed SL8 laboratory fixing screw
and S8 clinical screw.

A1N

With ball attachment


Used to improve fixation and to stabilise dentures in the upper and lower jaws.
A straight abutment with ball attachment is used when the axes of positioned implants
diverge by up to 25; angled abutments are used for divergence of up to 60.
All abutments with ball attachments are provided with a holder, a detachable plastic liner,
and a protective disc. Angled abutments are supplied with an individually packed
SL8 laboratory fixing screw and an S8 clinical screw.

B1
1 mm

BCW
Standard
retention

16

B2
2 mm

BCP
Soft retention

B3
3 mm

B4
4 mm

BCY
Extra-soft
retention

B5
5 mm

HBC
Holder

B2A17
2 mm
Angled 17

PD
Protective disc

GenXT

Burnout with hex


Used for preparation of single constructions with transocclusal fixation
in the masticatory areas and when there is insufficient clinical height
for cement fixation (less than 4 mm). Can be used for preparation
of individual abutments for subsequent cement fixation
of aesthetic restorations. Supplied with an individually packed SL8
laboratory fixing screw and S8 clinical screw.

AB

ROOTFORM

WARNING!
A burnout abutment with hex on a metal platform should be used for high precision.

Burnout without hex


Used for preparation of bridge constructions with transocclusal fixation
in the masticatory areas, when there is insufficient clinical height
for cement fixation (less than 4 mm), and when the angles of positioned
implants diverge by up to 10. Supplied with an individually packed
SL8 laboratory fixing screw and S8 clinical screw.

ABR

Burnout with hex on metal platform


Used for preparation of highly aesthetic individual abutments from press-ceramics
and zirconium dioxide, allowing extremely precise aesthetic recreation
of the cervical part of the future construct. A state-of-the-art tool for skilled teams.
The non-metallic part is fixed to a metal platform with glue. This construct transfers
the loading of the fixing screw directly to the metal platform, which, in contrast
to all-zirconium abutments, protects them from stress and subsequent failure.
Supplied with an individually packed SL8 laboratory fixing screw and S8 clinical screw.

ABM

WARNING!
Should be used with individual gingival former.

17

GenXT

Laser-inscribed item ID
the first two numbers show the diameter (mm*10)
the second two numbers show the length (mm)

Colour indicator - length


16 mm

Colour indicator - diameter


3.5 mm
3.8 mm
4.2 mm
5.5 mm

ROOTFORM

16 mm
14 mm
12 mm
10 mm
8 mm

Pilot drill
2 mm

8 mm

Form drill
3.5 mm

D2008

10 mm

3.8 mm

4.2 mm

5.5mm

D3808

D4208

D5508

D2010

D3510

D3810

D4210

D5510

D2012

D3512

D3812

D4212

D5512

D2014

D3514

D3814

D4214

D5514

D2016

D3516

D3816

D4216

D5516

12 mm

14 mm

16 mm

Drill extender

ET
TP4

Punch
4.0 mm

18

TP5
5.0 mm

TP6
6.0 mm

Initial drill

D1508

Guide pin

P2

1.5 mm, L8 mm

GenXT
Extended version

Insertion tool, manual

IT

ITL

Insertion tool for angled handpiece

ITH

ITHL

Hex ratchet screwdriver

SD

SDL

Hex screwdriver for angled handpiece

SDH

SDHL

Hex screwdriver, manual

SDM

SDML

Instrument tray

TRR

Ratchet wrench

RW

Torque wrench (15-50 Ncm)

TW50

Depth measuring gauge

DPG

ROOTFORM

Standard length

19

COMPRESSIVE

COMPRESSIVE

Compressive
implants

21

GenXT

Improved Abutment platform


High-precision cone
Round indicator
Three recesses
Optimum size
compact abutment size with round indicator and high-precision cone
provides more accurate and aesthetic constructions
The three recesses make implant placement safer,
protecting the abutment from unwanted damage

COMPRESSIVE

Implant neck
special design
polished surface

Bendable up to 15 degrees the abutment allows implants to be placed


at the optimum bone site
polished surface protects from accumulation of bacteria
at the cervical part of the implant

Apical part
Minimal dimensions

Allows the inferior alveolar nerve to be avoided


Self tapping apex

22

GenXT

Intraosseous part
special compression thread
radial microthread space
tapered
apical part - small diameter
middle part - medium diameter

COMPRESSIVE

pre-cervical part - large diameter

when inserting into cancellous trabeculae, the special compression implant thread
produces compression, creating a layer of cortical bone around the implant,
with reliable macrofixation
allows immediate implant loading with high primary stability
this compact layer then transforms into cancellous bone,
which is accompanied by osseointegration

Cortical bone zone


immediately after
implant positioning

Osseointegrated zone
180 days after
implant positioning

The combination of these factors provides successful osseointegration


and reliable and early functioning of prosthetic constructions,
reducing the length of treatment.

23

GenXT

The COMPRESSIVE implant is a single-component implant


with a compression thread. It is used for multiple unit restorations with
immediate loading in the upper and lower jaws with adequate bone
tissue. It can be used in combination with basal implants and allows flap
and flapless placement. Abutment direction can be adjusted using a
special instrument up to 15 relative to the implant axis. Can be used with
caution to create single restorations in situations where high primary
stability is achieved on placement.

Simple placement and prosthetic procedure

COMPRESSIVE

Immediate loading
Excellent primary stability in all types of bone
Adjustable abutment angle
Resistant to cervical fractures

Logic of selection

Special compressive thread

24

GenXT

3.5 mm

8 mm

4.0 mm

4.5 mm

5.0 mm

5.5 mm

C4008

C4508

C5008

C5508

10 mm

C3010

C3510

C4010

C4510

C5010

C5510

12 mm

C3012

C3512

C4012

C4512

C5012

C5512

14 mm

C3014

C3514

C4014

C4514

C5014

C5514

16 mm

C3016

C3516

COMPRESSIVE

3.0 mm

25

GenXT
Transfers
Used to take closed transfers of single-component implants. The transfer construction
provides reliable fixation of the transfer in the tray. The preferred material for transfer is
Addition Silicon. The transfer can be modified in case of restricted space.

TRA

Implant analogue
Used for model preparation. Use of plastic provides the model with elasticity corresponding to
the micromobility of the implant. The special antirotation shape prevents macromobility while
working with the analogue, maintaining minimal size preventing interference with placing
when implants are close together.

ANA

Burnout cap
COMPRESSIVE

Used to prepare high-precision metal body for precise alignment and to prevent cementing

BOP

failure. The round indicator which matches to the indicator on the abutment shows
the height adjustment of the abutment. The opening in the upper part of the burnout cap,
combined with the colour contrast (red-yellow), gives an accurate impression of the fit
on the analogue, preventing misalignment in clinical situations. Available in Straight , 15
degree , 25 degree and shoulder margin patterns.

Form drilling
Initial drilling
Check depth
and direction

Use Drills in Sequence till Implant Diameter

Use expansion
Screw if
Required

Implant
positioning
C3010

Drill speed (rpm)

800 - 1200

1200-1500
Sequential drilling with cone drills of increasing diameter.
If the bone density is insufficient, we recommend reducing
the drill diameter by one step or positioning after pilot drilling.

26

15-25

GenXT

Laser-inscribed item ID
the first two numbers show the diameter (mm*10)
the second two numbers show the length (mm)

Colour indicator - length


14 mm
16 mm

Colour indicator - diameter


16 mm
14 mm
12 mm
10 mm
8 mm

3.0 mm
3.5 mm
4.0 mm
5.0 mm
5.5 mm

Form drills and compression screws


3.5 mm

8 mm

4.0 mm

5.0 mm

5.5 mm

DC4008 CS4008 CS4508

DC5008 CS5008

DC5508 CS5508

10 mm

DC3010 CS3010

DC3510 CS3510

DC4010 CS4010 CS4510

DC5010 CS5010

DC5510 CS5510

12 mm

DC3012 CS3012

DC3512 CSS3512

DC4012 CS4012 CS4512

DC5012 CS5012

DC5512 CS5512

14 mm

DC3014 CS3014

DC3514 CS3514

DC4014 CS4014 CS4514

DC5014 CS5014

DC5514 CS5514

16 mm

DC3016 CS3016

DC3516 CS3516

COMPRESSIVE

3.0 mm

27

GenXT

Initial drill

D1508

1.5 mm, L8 mm

Punch

TP4

TP5

Insertion tool for angled handpiece

ITEH

ITEHL

Insertion tool for wrench

ITE

ITEL
Extended version

ITEXL
Extraextended version

COMPRESSIVE

Standard length

TP6

28

Instrument tray

TRR

Ratchet wrench

RW

Torque wrench (15-50 Ncm)

TW50

Depth measuring gauge

DPG

BASAL

BASAL

Basal
implants

29

GenXT

Improved Abutment platform


High-precision cone
Round indicator
Three recesses
Optimum size
compact abutment size with round indicator and high-precision cone
provides more accurate and aesthetic constructions
The three recesses make implant placement safer,
protecting the abutment from unwanted damage

Implant neck
Special design
Polished surface

Depending on the length of the implant the abutment can be bent from
15 - 25 degrees , as long as the implant is placed in sound bone
polished surface protects from accumulation of bacteria
at the cervical part of the implant

BASAL

Surface
Polished surface

Prevents bacteria and plaque from adhering to the implant


neck or body

Implant body
Thin implant body combined with wide thread turns

Allows increased vascularity around the implant and high


bone implant contact

30

GenXT

The last thread turn


The last turn is milled at an angle to the neck
prevents spontaneous rotation around its axis

Sizes
large diameter
short height

the macrostructure of large-diameter basal implants are well suited


to cases where there is insufficient bone tissue height.

Integration
BASAL

the implant should always be anchored in basal bone


placement of implants in areas not subject to bone resorption
stability of implants essential to allow for osseointigration

These factors combine to provide successful osseointegration


even in the most difficult clinical situations. Using these implants
significantly reduces treatment costs and makes it possible to do
immediate loading even in complex cases.

31

GenXT
BASAL implants are used to create multiple unit restorations in the upper
and lower jaws. They can be placed in extraction sockets and also in healed
bone. The structural characteristics allow placement in bone that is deficient in
height and width. They can be placed with flap or flapless technique.
A good understanding of the maxillofacial anatomy is recommended so that
bi-cortical engagement is achieved. Can be used to bypass the mandibular
nerve, and for engagement of the cortical bone at the fusion of the pterygoid
with the maxilla. Can be used in combination with compressive implants.
Using a special instrument abutment direction can be adjusted up to 15
relative to the implant axis.

Ideal for resorbed ridges


Immediate loading
Placement in the socket of an extracted tooth
Improved abutment
Excellent protection from periimplantitis around the implant

Logic of selection

BASAL

Adjustment of abutment angle up to 15

32

10 mm

12 mm

14 mm

16 mm

18 mm

20 mm

22 mm

24 mm

26 mm

3.5 mm B3510

B3512

B3514

B3516

B3518

B3520

B3522

B3524

B3526

4.5 mm B4510

B4512

B4514

B4516

B4518

B4520

B4522

B4524

B4526

5.5 mm B5510

B5512

B5514

B5516

6.5 mm B6510

B6512

B6514

B6516

8.5 mm B8510

B8512

B8514

10.5 mm B1110

B1112

B1114

BASAL

GenXT

33

GenXT
Transfers
Used to take closed transfers of single-component implants. The transfer construction
provides reliable fixation of the transfer in the tray. The preferred material for transfer is
Addition Silicon. The transfer can be modified in case of restricted space.

TRA

Implant analogue
Used for model preparation. Use of plastic provides the model with elasticity corresponding
to the micromobility of the implant. The special antirotation shape prevents macromobility
while working with the analogue, maintaining minimal size preventing interference with

ANA

placing when implants are close together.

Burnout cap
BOP

Used to prepare high-precision metal body for precise alignment and to prevent cementing
failure. The round groove which matches the groove on the abutment can be used as a
reference for the height adjustment of the abutment. The opening in the upper part of the
burnout cap, combined with the colour contrast (red-yellow), gives an accurate impression of
the fit on the analogue, preventing misalignment in clinical situations.

For Ease of insertion

BASAL

Initial drilling

Implant
positioning
B4514

Cortical Bone Layer


Drill speed (rpm)

34

1200-1500

1200-1500

15-25

GenXT

Laser-inscribed item ID
the first two numbers show the diameter (mm*10)
the second two numbers show the length (mm)

Colour indicator - length


20 mm
22 mm
24 mm
26 mm

20 mm

Expansion
screws

Form drills
22 mm

24 mm

26 mm

BASAL

20 mm

Colour indicator - diameter


18 mm
2.0 mm
2.3 mm
16 mm
14 mm
12 mm
10 mm
8 mm

2.0 mm

DB2020

DB2022

DB2024

DB2026

CS8514

CS1114

D2016

35

GenXT

Initial drill

D1508

1.5 mm, L8 mm

Punch

TP4

TP5

Insertion tool for angled handpiece

ITEH

ITEHL

Insertion tool for wrench

ITE

ITEL
Extended version

ITEXL
Extraextended version

COMPRESSIVE

Standard length

TP6

36

Instrument tray

TRR

Ratchet wrench

RW

Torque wrench (15-50 Ncm)

TW50

Depth measuring gauge

DPG

GenXT

Information
for clinics
and patients

39

GenXT
TRATE can provide a complete set of documents for communicating with patients.
These documents which use plain language and clear illustrations, are useful
for patients and dentists alike. They help patients decide how to solve problems
due to damage or loss of a single tooth, several teeth, or complete edentulation.

For the waiting room


Patient education is an important part of medical care. Properly explaining and presenting
treatment plans help to build trust and to resolve any problems that are likely to arise.
Our patient communication tools work from the moment the patient enters the waiting room.
We have a wide range of materials, including brochures, posters, and documents on electronic
media available for use.

GenXT
Bring back your smile!

Bring back your smile!


Comprehensive information explaining what implantation is
and why tooth loss cannot be ignored.
Brochure
REF 0100 English
REF 0101 German
REF 0102 Russian

Poster
REF 0110 English
REF 0111 German
REF 0112 Russian

GenXT

Lost or damaged a tooth?

Lost or damaged a tooth?


Information explaining why even a single missing or damaged tooth cannot be ignored.
Brochure
REF 0200 English
REF 0201 German
REF 0202 Russian

GenXT

Lost more than one tooth?

Poster
REF 0210 English
REF 0211 German
REF 0212 Russian

Lost more than one tooth?


Information explaining why several missing teeth cannot be ignored.
Description of restoration solutions.
Brochure
REF 0300 English
REF 0301 German
REF 0302 Russian

GenXT
Living with a denture
or with no teeth?

Poster
REF 0310 English
REF 0311 German
REF 0312 Russian

Living with a denture or with no teeth?


Information explaining why the use of dentures and older prostheses
is not the ideal solution. It describes how missing teeth can be restored.
Brochure
REF 0400 English
REF 0401 German
REF 0402 Russian

40

Poster
REF 0410 English
REF 0411 German
REF 0412 Russian

GenXT

During the consultation


We have developed a flipchart presentation to back up patient consultations visually.
The presentation will back up your explanations and the high-quality images help bring home
what you are saying. The reverse of the flipchart has additional information.

Catalogue of implantation
used by the Open Dental Community
Catalogue
of implantation

Catalogue
of implantation

This series of documents will help you to illustrate the possible missing tooth replacement solutions
during consultations. Solutions are based on the document "Catalogue of implantation used
by the Open Dental Community", which gives the patient confidence in the proposed treatment.

All solutions brochure


REF 0500 English
REF 0501 German
REF 0502 Russian

All solutions app for iPad


REF 0520 English
REF 0521 German
REF 0522 Russian

All solutions flipchart


REF 0510 English
REF 0511 German
REF 0512 Russian

FLASH version for website


REF 0530 English
REF 0531 German
REF 0532 Russian

After treatment
Special patient brochure - "Life with a smile" - which helps maintain dentist-patient relations
after treatment. The brochure includes information about your clinic in the form of a tear-off
card with your contact details so the patient can always find you in emergencies or for further
advice. It is also a guarantee to the patient that you use high-quality TRATE products.

The "Life with a smile" brochure


GenXT

Life with a smile

General information about implants, advice on hygiene and the need for regular check-ups.
The brochure provides information about TRATE's implant and superstructure guarantees.
The brochure includes pages for entering post-implantation guidance. TRATE recommends
use of the "Life with a smile" brochure after each implantation to boost patient confidence.
Ref 0600 English
Ref 0601 German
Ref 0602 Russian

For further information on how TRATE can help you communicate with patients,
visit our website at www.GenXT.ch or contact your TRATE representative.

41

GenXT

Notes

42

GenXT

43

GenXT

44

REGIONAL OFFICES
Belarus
TOP RATE IMPLANTS, OOO
Kiseleva st.55-11
220002 Minsk

Latvia
TRATE AG office in Latvia
ertrdes st. 109-1
1009 Riga

Lithuania
TRATE AG office in Lithuania
Vilniaus st. 31/1 (4th Floor, Room No. 6)
01402 Vilnius

Poland
TRATE AG office in Poland
G rczewska st. 24, m.58
01147 Warszawa

Russia
TOP RATE IMPLANTS, OOO
Rustaveli 14-6
127254 Moscow

Spain
TRATE AG office in Spain
Calle de Santiago 19-21
47001 Valladolid

Ukraine
nstitut Botehnologj
Srbnokl's'ka st.12, sekcja B
02068 Kiev

REF. CATALOG 12 Printed in Switzerland TRATE AG, 2012. All rights reserved.
The TRATE logo and other trade marks are registered trade marks of TRATE, unless otherwise stated in the text.
Images of implants at scale 1:1.25

TRATE AG
Seestrasse 58
8806 Bch
Switzerland
India
Mr. Bhalotia
Info@genxtimplantology.com

Genxtimplantology.com

You might also like