You are on page 1of 32

SELECTION GUIDE

FIXED SPEED CONTROL


DIRECT ONLINE STARTERS
SOFT STARTERS
THE INTELLIGENT MOTOR CONTROL SOLUTION
FOR YOUR APPLICATION REQUIREMENTS

Intelligent Motor Control

Intelligent Motor Control with Fixed Speed Starters

Product features

Product selection
E1 Plus Electronic Overload Relays

E3 and E3 Plus Electronic Overload Relays

10

825-P Modular Protection System

12

SMC-Flex Smart Motor Controllers

14

ArmorStart Distributed Motor Controllers

18

Short-Circuit Coordination

24

Functionality Overview

26

Rockwell Automation, Allen-Bradley, PowerFlex, ArmorPoint, ArmorConnect, ArmorStart


are registered trademarks of Rockwell Automation. DeviceLogix, DeviceNet are trademarks of
Rockwell Automation.

AN INTEGRAL PART OF YOUR

INTEGRATED
ARCHITECTURE

FIXED SPEED
CONTROL

We understand that you need to control performance, reduce


downtime, improve safety, increase productivity, perform
diagnostics. Thats why weve combined leading-edge motor
control and protection devices with the advanced networking
and diagnostic capabilities of Rockwell Automations Integrated
Architecture to provide you with Intelligent Motor Control.

Direct Online
Starters

With solutions for a variety of motor control requirements and


devices hosting in-built intelligence, control of your motor
applications can be truly integrated into your solution. Seamless
integration allows your to monitor, control, program and
interrogate your motor control solutions to achieve the
efficiency, reliability and control you demand. With different
levels of integration available, there is an integrated solution
ideal for you.

WHAT YOU CAN ACHIEVE WITH INTEGRATED ARCHITECTURE


AND INTELLIGENT MOTOR CONTROL SOLUTIONS...

Optimise motor performance through intelligent equipment and networks


Reduce your energy consumption and increase efficiency
Reduce downtime in the event of drive damage with automatic device replacement (ADR)
Alerts you about motor problems before a failure occurs
Embed safety functionality to protect your process, personnel and equipment health
Achieve seamless communication and system visibility for increased system performance,
simplified troubleshooting and reduced startup times
and much more...

Soft
Starters

NetLinx
(EtherNet/IP, ControlNet, DeviceNet)

MOTION
CONTROL

VARIABLE SPEED
CONTROL

Low Voltage
AC Drives

Medium Voltage
AC Drives

Engineered
Drive Solutions

Servo
Drives

Servo
Motors

FIXED SPEED
CONTROL

Direct Online
Starters

E1 PLUS ELECTRONIC OVERLOAD RELAYS

E3 AND E3 PLUS ELECTRONIC OVERLOAD RELAYS

825-P - MODULAR
PROTECTION SYSTEM

0.1...800 A Current Range

0.4...860 A Current Range


9...5000 A Current Range with
Current Transformer

0.55000 A Current Range

DeviceNet Communication
integrated

Modular design with pluggable options


- Voltage input cards, including
DeviceNet communications
- RTD scanner module

Self-Powered
Fast Phase Loss Protection
Wide adjustment Range (5:1)
Low Energy
Consumption (150mW)
Visible Trip Indication
Side mount Communications Modules

Adjustable trip Class (530)


Programmable trip and
warning settings

Suitable for low- and medium- voltage


applications

Comprehensive protection functions

Diagnostic functions
(History of last 5 trips)

Built-in keypad and backlit 2-Line LCD

DeviceLogix component technology

3 Output relays
2 Configurable inputs

RELAYS E3
2 Inputs

1 Output

RELAYS E3 PLUS
4 Inputs

Status LEDs

2 Outputs

Built-in ground fault


sensor (through 90 A rating)
PTC thermistor input

Direct online Starting


Rockwell Automation offers a complete portfolio of
Allen-Bradley electronic motor protection relays with
communications that allow you immediate access to status
information, motor performance data, and diagnostics,
as well as the capability to perform control functions.

Distributed Motor Control


For your applications needing machine mounted motor
control, the ArmorStart Distributed Motor Controllers offer
a simple, cost-effective method of integrating motor
control, I/O and network capabilities in your on-machine
architecture. The ArmorStart is an integrated,
pre-engineered combination starter for full voltage DOL,
reversing, Soft starting and variable speed drive applications. The components are mounted closer to the application or on the machine reducing panel space as well as
wiring and conduit requirements making it easier to install
and start-up. Save more time by configuring intelligent
devices via the network and reduce at the same time
potential errors.

Soft Starting
Smart Motor Controllers (SMCs) minimize mechanical
wear resulting from full-voltage starting of AC induction
motors, enabling longer system life as well as limit line
disturbances from inrush currents, resulting in reduced
downtime.

Soft
Starters

ARMORSTART 280/281D DISTRIBUTED MOTOR CONTROLLERS

SMC-FLEX SMART MOTOR COTROLLERS

ARMORSTART 283D DISTRIBUTED MOTOR CONTROLLERS

0.187.5 kW (400V)

11250/1600 A Current Range

0.375.5 kW (400V)

Full Voltage DOL and Reversing starting

Soft Start

Current Limit Start, Soft Start, Soft Stop

IP69K/NEMA Type 4X or IP67/


NEMA Type 4 enclosure ratings

Current Limit Start


Full Voltage

IP69K/NEMA Type 4X or IP67/


NEMA Type 4 enclosure ratings

Modular plug and play design

Preset Slow Speed

Modular plug and play design

Network Communications with


DeviceNet including DeviceLogix

Soft Stop

Network Communications with


DeviceNet including DeviceLogix

4 Inputs and 2 Outputs

Options
Pump Control

4 Inputs and 2 Outputs

Quick Disconnects for I/O,


Communications, Motor Connection
and Control Power

Quick Disconnects for I/O,


Communications, Motor Connection
and Control Power

Braking Control

NETWORK
COMMUNICATION

E1 Plus electronic overload relays are the industrys rst modular self-powered devices, setting
a new standard for entry level motor protection.
The network communications modules expand
the functionality. Its compact, simplied control,
and exibilitys allows you to network motor
starters more cost efciently. Streamline
processes with enhanced control, protection,
monitoring, and diagnostic capability for improved operating efciency.

The unique line-side over molded power connections on the E1 Plus, on the E3, and E3 Plus
make for a sturdy two-component starter assembly that is unmatched in the industry. The preformed power connections allow for easy starter
assembly every time.

E3 Overload Relays control functions deliver


effective motor management to help prevent
and minimize production downtime. Critical
protective functions can prevent motor damage
and provide advance notication of a machines
performance being outside the boundaries of
normal operation.
Network communication delivers immediate
access to motor performance and diagnostic
data in addition to seamless control. Integrated
I/O provides convenient local termination of
motor-related inputs and outputs, simplifying
the control architecture. DeviceLogix component technology increases the control possibilities with function block programs that operate
at the device level.

PROTECTION

CONTROL

COMMUNICATIONS

Delta Connections

The SMC-Flex is a compact and cost-effective package


for your production applications. As standard, the
SMC-Flex includes I/O, electronic overload, integral
bypass, advanced communication capabilities, motor
starting capabilities for both star-delta and standard
squirrel-cage induction motors, advanced protection
and diagnostics.
The SMC-Flex is also available for medium voltage
applications with the same features and benets for
controlling motors rated up to 7.2 kV and 7500 hp
(5600 kW).

1/L1

2/T1

3/L2

4/T2

M
3~

Line Connection

5/L3

6/T3

The SMC-Flex provides 3 Phase Control


and excellent performance in a
compact design for your standard
squirrel cage or Star-Delta
induction motors.

Benefits of using DeviceLogix


Faster sense-to-actuate response
Local processing
Higher network performance
Increased system reliability
Improved diagnostics and reduced troubleshooting
Reducing potential points of failure at system level
Increasing uptime through distributing ControlLogic
throughout system
Enables reliability in operation under failures or during
maintenance operations

What is DeviceLogix?
DeviceLogix is a stand-alone Boolean program that resides
within the ArmorStart.

Increased system/machine modularity


Distributing control on the machine
Smaller programs in the master system scan
and processing times

DeviceLogix is programmed using Boolean math operations


such as AND, OR, NOT, Timers, Counters, and Latches.
RSNetWorx for DeviceNet Version 3.0 or later is required
to program the device.
IP69K Rated ArmorStart!
The IP69K rated ArmorStart Distributed Motor Controller
is suitable for harsh production environments. Rated for
environment high pressure wash down with caustic
chemicals used in the food and beverage industry
(i.e. sodium hydroxide exposure). The IP69K rated
ArmorStart offers the same features as the IP67 rated
ArmorStart.

Peer to Peer
Communications (ZIP)
The new Zone Control capabilities of ArmorStart Distributed
Motor Controller is ideal for large horsepower motored
conveyors. The ArmorStart Distributed Motor Controller have
built-in DeviceNet Communications, DeviceLogix technology
and the added Zone Interlocking Parameters (ZIP) which
allows one ArmorStart to consume data directly from up
to four other DeviceNet nodes without going through the
network scanner. These direct communications between
conveyor zones are beneficial in merge, diverter and
accumulation conveyor applications.

E1 PLUS

Description

0.1...800 A Current Range


Self-Powered
Fast Phase Loss Protection
Wide Adjustment Range (5:1)
1 N.O. and 1 N.C. Isolated auxiliary Contacts
(B600, AC-15 Rated)

Low Energy Consumption (150 mW)


Ambient Temperature Compensation
Visible Trip Indication
Jam/Remote Reset optional accessoires
Side-mount Modules for enhanced Motor Protection

Mounts to Contactor

Adjustment Range
[A]

Cat. No.

Three-Phase Devices 193-ED


0.127 A Current Range
Fixed Trip Class 10
Manual Reset

100-C09100-C23

0.10.5

193-ED1AB

0.21.0

193-ED1BB

1.05.0

193-ED1CB

3.216

193-ED1DB

5.427

193-ED1EB

100-C09100-C23

0.10.5

193-EEAB

100-C09100-C23

0.21.0

193-EEBB

100-C09100-C23

1.05.0

193-EECB

100-C09100-C23

3.216

193-EEDB

100-C09100-C23

5.427

193-EEEB

100-C30100-C43

5.427

193-EEED

100-C30100-C43

945

193-EEFD

Three-Phase Devices 193-EE

0.1800 A Current Range


Selectable Trip Class (10, 15, 20 or 30)
Selectable Manual/Auto-Manual Reset
Single-Phase and Devices with Cage Clamp Control
Terminals are also available,
see publication 193-SG009_-EN-P.

100-C60100-C85

1890

193-EEGE

100-D95100-D180

30150

193-EEHF

100-D95100-D180

40200

193-EEJF

100-D210100-D420

40200

193-EEJG

100-D210100-D420

60300

193-EEKG

100-D210100-D420

100500

193-EELG

100-D630100-D860

120600

193-EEMH

100-D630100-D860

160800

193-EENH

Description

For Use With

Cat. No.

193-EE

193-EDN

Jam Protection Module with Remote Reset


Side-mount module with trip level settings of 150, 200, 300
and 400% FLA, and delay time settings of 0.5, 1.0, 2.0
and 4 seconds. For remote resetting of a trip condition.
Supply voltage required.

193-EE

193-EJM

Ground Fault Module with Remote Reset


Side-mount module for core-balanced ground fault protection,
adjustable trip level 20 mA...5 A. Supply voltage required.

193-EE

193-EGF

Ground Fault/Jam Module with Remote Reset


Side-mount module for core-balanced ground fault protection,
adjustable trip level 20 mA...5 A; Jam protection with fixed trip level
setting of 400% FLA, fixed delay time setting of 0.5 seconds.
Supply voltage required.

193-EE

193-EGJ

100-C09...C37

193-CBCT1

100-C09...C85

193-CBCT2

193-EE

193-ERR

193-ED1_B, 193-EE_B
193-ED1_B, 193-EE_B
193-EE_E

193-EPB
193-EPD
193-EPE

DeviceNet Communications Module


Integrated I/O allow simplification of the network
architecture, providing local connection of motor starter
related inputs and outputs.
2 Inputs 24V DC rated, module supplied
1 Output B300 rated

Core Balance Ground Fault Sensors


Max. 45 A; Window 19.1 mm
Max. 90 A; Window 39.6 mm
Remote Reset Module
For remote resetting of a trip condition.
Supply voltage required.
DIN Rail/Panel Adapter
For separate mounting can be mounted
to top-hat rail EN 50 022-35.
External Reset Button
For enclosed, through-the-door reset applications.
Metal construction IP66, non-illuminated with rod
(length: 142 mm, adjustable range 141159 mm).
Refer to the 800F catalog pages for additional types.

193-ED (all)
193-EE (all)

Current Adjustment Shield


Prevents inadvertent adjustment of the current setting.
Must be ordered in multiples of package quantities.
Package Quantity = 10

193-ED (all)
193-EE (all)
592-EE (all)

193-BC8

External Reset Adapter


For enclosed, through-the-door reset applications.
Use with External Reset Button.

193-ED (all)
193-EE_B,
193-EE_D,
193-EE_E

193-ERA

100-D140, 100-D180,
100-D95ED180E,
193-EC_F, 193-EE_F

100-DTB180

100-D210...100-D420,
193-EC_G, 193-EF2C,
193-EE_G

100-DTB420

100-D95100-D180,
193-EC_F, 193-EE_F

100-DTC180

Terminal Lugs
Set of 2
Protection class IP2X per IEC 60529 and DIN 40 050

Terminal Covers
Protection class IP20 per IEC 60529 and DIN 40 050
For direct-on-line, reversing, two-speed,
and wye-delta/star-delta assemblies
Phase Barriers
Set of 4

100-D210...100-D420,
193-EC_G, 193-EE_G
100-D630100-D860,
193-EC_H, 193-EE_H
100-D630D860,
193-EC_H, 193-EE_H

800FP-R611
800F-ATR08

100-DTC420
100-DTC860
100-DPB860

E3 & E3 PLUS
0.4...860 A Current Range
9...5000 A Current Range with Current Transformer

DeviceNet communication integrated


LED indicators
Test / Reset button
Adjustable trip Class (530)
Integrated I/Os E3: 2 Inputs / 1 Output
E3 Plus: 4 Inputs / 2 Outputs

Low-level ground (earth) fault protection 193-EC2


Ground fault range 15 A

PTC thermistor input 193-EC2


Programmable trip and warning settings
Diagnostic functions (History of last 5 trips)
DeviceLogix (series B)

Relay
193-EC1
Mounts to Contactor

100-C09100-C23

100-C30100-C43

100-C60100-C85
100-D95100-D180

100-D210100-D420

100-D630100-D860

Relay
193-EC2

Adjustment Range [A]

Cat. No.

Cat. No.

0.42

193-EC1PB

193-EC2PB

15

193-EC1AB

193-EC2AB

315

193-EC1BB

193-EC2BB

525

193-EC1CB

193-EC2CB

15

193-EC1AD

193-EC2AD

315

193-EC1BD

193-EC2BD

525

193-EC1CD

193-EC2CD

945

193-EC1DD

193-EC2DD

945

193-EC1DE

193-EC2DE

1890

193-EC1EE

193-EC2EE

28140 

193-EC1FF

193-EC2FF

42210 

193-EC1GF

193-EC2GF

42210 

193-EC1GG

193-EC2GG

60302 

193-EC1HG

193-EC2HG

84420 

193-EC1JG

193-EC2JG

125630 

193-EC1KH

193-EC2KH

172860 

193-EC1LH

193-EC2LH

 Does not include terminal lugs.

10

Description
2 Inputs
1 Output

4 Inputs
2 Outputs
Ground fault sensor input
PTC thermistor input
DeviceLogix

Adjustment Range [A]

Cat. No.

95000

193-EC1ZZ

95000

193-EC2ZZ

Current transformers supplied by customer.


Order panel adapter 193-ECPM2 separately.
See table below for CT Ratio to FLA setting range correlation. Discount Schedule MPC

CT Ratio

FLA Setting
Range (A)

CT Ratio

FLA Setting
Range (A)

CT Ratio

FLA Setting
Range (A)

50:5
100:5
150:5
200:5

945
1890
28140
42210

300:5
500:5
600:5
800:5

60302
84420
125630
172860

1200:5
2500:5
5000:5

2401215
4502250
10005000

Description

DIN Rail/Panel Adapter 

AC Input Interface Module


rated 110/120V AC, 50/60 Hz

Core Balance Ground Fault Sensor

Terminal Lugs
Set of 2
Protection class IP2X per IEC 60529 and DIN 40 050

Terminal Covers
Protection class IP20 per IEC 60529 and DIN 40 050
For direct-on-line, reversing, two-speed,
and wye-delta/star-delta assemblies

Phase Barriers
Set of 4
 The electronic motor protection relay can be mounted separately to top-hat rail EN 50 02-35.
11

For Use With

Cat. No.

193-EC__B

193-ECPM1

193-EC_D, 193-EC_ZZ

193-ECPM2

193-EC__E

193-ECPM3

193-EC all
592-EC all

193-EIMD

193-EC2_F, 193-EC2_G,
193-EC2_H, 193-EC2ZZ

825-CBCT

100-D140, 100-D180,
100-D95ED180E,
193-EC_F, 193-EE_F

100-DTB180

100-D210...100-D420,
193-EC_G, 193-EF2C,
193-EE_G

100-DTB420

100-D95100-D180,
193-EC_F, 193-EE_F

100-DTC180

100-D210...100-D420,
193-EC_G, 193-EE_G

100-DTC420

100-D630100-D860,
193-EC_H, 193-EE_H

100-DTC860

100-D630D860,
193-EC_H, 193-EE_H

100-DPB860

825-P
0.55000 A Current Range
Suitable for low- and medium-voltage applications
Modular design with pluggable options
- Voltage input cards
- Expansion I/O cards
- Communications cards, including DeviceNet
- RTD scanner module
Comprehensive protection functions
Built-in keypad and backlit 2-Line LCD
Test / Reset button
Status LEDs
3 Output relays
2 Configurable inputs

Description

Cat. No.

Cat. No.

Basic Unit
Note: The minimum requirements
for a complete basic system are one
Basic Unit and one Converter Module.

120240V AC/DC

825-PD

User Manual
Ships separate from Basic Unit.
Please consult your local sales office.

825-UM004_-EN-P

Converter Module

Core Balance Ground Fault Sensor

RTD Scanner Module


12 RTD input channels with individual
programming for 10 copper, 100
nickel, 120 nickel, or 100 platinum.
Fiber optic connection to Basic Unit.
Class I, Division 2, Group T48

 Please consult your local sales office for factory configurated devices with option cards.

12

0.52.5 A

825-MCM2

2.520 A

825-MCM20

20180 A

825-MCM180

160630 A

825-MCM630N

100:1

825-CBCT

120 / 240V AC

825-PR12D

Description
Voltage Input Card
Monitoring of VA, VB, VC, and VN
Expansion I/O Card
(3) Inputs
(4) Output Relays
(1) 420 mA Analog Output

Cat. No.
240V AC Max. 

825-PVS

120V AC Rated Inputs 

825-PIOD

24V DC Rated Inputs 

825-PIOR

DeviceNet Communication Card


DeviceLogix technology, Node address selection switches, 
ODVA conformance tested

825-PDN

Modbus RTU Communication Card

825-PMB

M8 connections
Set of 3
4 x 16 x 102 mm (1/8 x 5/8 x 4-1/64 in.) (125 A max.)
Universally applicable
Weight: 230 g

825-MVM

M8 connections
Set of 3
4 x 20 x 117 mm (180 A max.)
Universally applicable

825-MVM2

M6 lower connections
Set of 3
For mounting on 100-D95 and 100-D110 contactors with conventional coil

825-MVS

M8 lower connections
Set of 3
For mounting on 100-D140, 100-D180 conventional and
100-D95E100-D180E contactors with electronic coil

825-MVS2

Terminal Shields
Set of 2
Protection class IP10 per IEC 60529
and DIN 40 050
For direct-on-line, reversing, two-speed,
and wye-delta/star-delta assemblies

Terminal Lugs
Set of 2
Protection class IP2X per IEC 60529
and DIN 40 050

Thermal Utilization Meter

Connection cable (replacement)


825-P to 825-MCM connection

100-D95, 100-D110

100-DTS110

100-D140, 100-D180,
100-D95-E100-D180-E

100-DTS180

100-D210...100-D420

100-DTS420

100-D95, 100-D110

100-DTB110

100-D140, 100-D180,
100-D95ED180E,
193-EC_F, 193-EE_F

100-DTB180

100-D210...100-D420,
193-EC_G, 193-EF2C,
193-EE_G

100-DTB420

For display of percent


thermal capacity utilized
Requires the use of an
Expansion I/O Card

825-MTUM

825-MCA

13

SMC-FLEX

11250/1600 A Current Range


Built-in Electronic Overload Protection
Soft Start
Current Limit Start
Dual Ramp
Full Voltage
Linear Speed Acceleration
Preset Slow Speed
Soft Stop

Options
Pump Control
Braking Control

Rating for line


connection 

Rating for delta


connection 

Motor
Current
[A]

400V
[kW]

Motor
Current
[A]

400V
[kW]

15

2.2

1.78.7

5...25

11

8.743

22

8.6...43

22

14.974

37

12...60

30

20.8...104

55

17...85

45

29.4147

75

27108

55

47187

90

34135

75

59234

132

67201

110

116348

160

84251

132

145435

250

106317

160

183549

135

120361

200

208625

355

160480

250

277831

450

208625

355

283850

500

260780

450

300900

500

323...970

560

4001200

710

4161250

710

5331600

900

Without
Option

With Pump
Control Option

With Braking
Control Option

Control Voltage

Cat. No.

Cat. No.

Cat. No.

100...240V AC 50/60 Hz
24V AC/DC 
100...240V AC 50/60 Hz
24V AC/DC 
100...240V AC 50/60 Hz
24V AC/DC 
100...240V AC 50/60 Hz
24V AC/DC 
100...240V AC 50/60 Hz
24V AC/DC 
100...240V AC 50/60 Hz
24V AC/DC 
100...240V AC 50/60 Hz
24V AC/DC 
100...240V AC 50/60 Hz
24V AC/DC 
100...240V AC 50/60 Hz
24V AC/DC 
100...240V AC 50/60 Hz
24V AC/DC 
100...240V AC 50/60 Hz
24V AC/DC 
100...240V AC 50/60 Hz
24V AC/DC 
110/120V AC 50/60 Hz
230/240V AC 50/60 Hz
110/120V AC 50/60 Hz
230/240V AC 50/60 Hz
110/120V AC 50/60 Hz
230/240V AC 50/60 Hz
110/120V AC 50/60 Hz
230/240V AC 50/60 Hz

150-F5NBD
150-F5NBR
150-F25NBD
150-F25NBR
150-F43NBD
150-F43NBR
150-F60NBD
150-F60NBR
150-F85NBD
150-F85NBR
150-F108NBD
150-F108NBR
150-F135NBD
150-F135NBR
150-F201NBD
150-F201NBR
150-F251NBD
150-F251NBR
150-F317NBD
150-F317NBR
150-F361NBD
150-F361NBR
150-F480NBD
150-F480NBR
150-F625NBE
150-F625NBA
150-F780NBE
150-F780NBA
150-F970NBE
150-F970NBA
150-F1250NBE
150-F1250NBA

150-F5NBDB
150-F5NBRB
150-F25NBDB
150-F25NBRB
150-F43NBDB
150-F43NBDR
150-F60NBDB
150-F60NBRB
150-F85NBDB
150-F85NBRB
150-F108NBDB
150-F108NBRB
150-F135NBDB
150-F135NBRB
150-F201NBDB
150-F201NBRB
150-F251NBDB
150-F251NBRB
150-F317NBDB
150-F317NBRB
150-F361NBDB
150-F361NBRB
150-F480NBDB
150-F480NBRB
150-F625NBEB
150-F625NBAB
150-F780NBEB
150-F780NBAB
150-F970NBEB
150-F970NBAB
150-F1250NBEB
150-F1250NBAB

150-F5NBDD
150-F5NBRD
150-F25NBDD
150-F25NBRD
150-F43NBDD
150-F43NBDR
150-F60NBDD
150-F60NBRD
150-F85NBDD
150-F85NBRD
150-F108NBDD
150-F108NBRD
150-F135NBDD
150-F135NBRD
150-F201NBDD
150-F201NBRD
150-F251NBDD
150-F251NBRD
150-F317NBDD
150-F317NBRD
150-F361NBDD
150-F361NBRD
150-F480NBDD
150-F480NBRD
150-F625NBED
150-F625NBAD
150-F780NBED
150-F780NBAD
150-F970NBED
150-F970NBAD
150-F1250NBED
150-F1250NBAD

14

Rating for line


connection 
Motor
Current
[A]

Rating for delta


connection 
Motor
Current
[A]

400V
[kW]

400V
[kW]

15

2.2

1.78.7

5...25

11

8.743

22

8.6...43

22

14.974

37

12...60

30

20.8...104

55

17...85

45

29.4147

75

27108

55

47187

90

34135

75

59234

132

67201

110

116348

160

84251

132

145435

250

106317

160

183549

135

120361

200

208625

355

160480

250

277831

450

208625

355

283850

500

260780

450

300900

500

323...970

560

4001200

710

4161250

710

5331600

900

Without
Option

With Pump
Control Option

With Braking
Control Option

Control Voltage

Cat. No.

Cat. No.

Cat. No.

100...240V AC 50/60 Hz

150-F5NCD
150-F5NBCR
150-F25NCD
150-F25NCR
150-F43NCD
150-F43NCR
150-F60NCD
150-F60NCR
150-F85NCD
150-F85NCR
150-F108NCD
150-F108NCR
150-F135NCD
150-F135NCR
150-F201NCD
150-F201NCR
150-F251NCD
150-F251NCR
150-F317NCD
150-F317NCR
150-F361NCD
150-F361NCR
150-F480NCD
150-F480NCR
150-F625NCE
150-F625NCA
150-F780NCE
150-F780NCA
150-F970NCE
150-F970NCA
150-F1250NCE
150-F1250NCA

150-F5NCDB
150-F5NCRB
150-F25NCDB
150-F25NCRB
150-F43NCDB
150-F43NCDR
150-F60NCDB
150-F60NCRB
150-F85NCDB
150-F85NCRB
150-F108NCDB
150-F108NCRB
150-F135NCDB
150-F135NCRB
150-F201NCDB
150-F201NCRB
150-F251NCDB
150-F251NCRB
150-F317NCDB
150-F317NCRB
150-F361NCDB
150-F361NCRB
150-F480NCDB
150-F480NCRB
150-F625NCEB
150-F625NCAB
150-F780NCEB
150-F780NCAB
150-F970NCEB
150-F970NCAB
150-F1250NCEB
150-F1250NCAB

150-F5NCDD
150-F5NCRD
150-F25NCDD
150-F25NCRD
150-F43NCDD
150-F43NCDR
150-F60NCDD
150-F60NCRD
150-F85NCDD
150-F85NCRD
150-F108NCDD
150-F108NCRD
150-F135NCDD
150-F135NCRD
150-F201NCDD
150-F201NCRD
150-F251NCDD
150-F251NCRD
150-F317NCDD
150-F317NCRD
150-F361NCDD
150-F361NCRD
150-F480NCDD
150-F480NCRD
150-F625NCED
150-F625NCAD
150-F780NCED
150-F780NCAD
150-F970NCED
150-F970NCAD
150-F1250NCED
150-F1250NCAD

24V AC/DC 
100...240V AC 50/60 Hz
24V AC/DC 
100...240V AC 50/60 Hz
24V AC/DC 
100...240V AC 50/60 Hz
24V AC/DC 
100...240V AC 50/60 Hz
24V AC/DC 
100...240V AC 50/60 Hz
24V AC/DC 
100...240V AC 50/60 Hz
24V AC/DC 
100...240V AC 50/60 Hz
24V AC/DC 
100...240V AC 50/60 Hz
24V AC/DC 
100...240V AC 50/60 Hz
24V AC/DC 
100...240V AC 50/60 Hz
24V AC/DC 
100...240V AC 50/60 Hz
24V AC/DC 
110/120V AC 50/60 Hz
230/240V AC 50/60 Hz
110/120V AC 50/60 Hz
230/240V AC 50/60 Hz
110/120V AC 50/60 Hz
230/240V AC 50/60 Hz
110/120V AC 50/60 Hz
230/240V AC 50/60 Hz

 Controllers rated 108 A and greater are not equipped with line and load terminal lugs.

 Motor FLA and Motor Running Current must fall within the running current range of the device to operate properly.
Utilization category: 5...480A AC-53b: 3-50: 1750
 Separate 120V or 240V single phase is required for fan operation.
625...1250A AC-53b: 3-50: 3550

a
Options
B
C
Z

Voltage Range
Up to 480V AC
Up to 600V AC
Up to 690V AC 

 For controllers rated 108...1250A only

b
Options
D
R
E
A

Voltage Range
100240V AC (5...480A units)
24 V AC/DC (5...480A units)
110/120V AC (625...1250A units)
230/240V AC (625...1250A units)

Optional Configurations

150-F108N

Options
Blank

Description
Standard
Pump Control
Provides smooth motor acceleration and deceleration,
reducing surges caused by the starting and stopping
of centrifugal pumps. Starting time is adjustable
from 030 seconds, and stopping time is
adjustable from 0120 seconds.

Braking Control
Provides Smart Motor Braking (SMB), Accu-Stop,
and Slow Speed with Braking. Prices on request.

15

Description
Protective Modules

Cat. No.


480V Protective Module
600V Protective Module

IEC Terminal Covers

585 A

150-F84

1081250 A

150-F84L

585 A

150-F86

1081250 A

150-F86L


Terminal Cover
IEC line or load terminal covers for 108...135 A devices.
Dead front protection

150-TC1

Terminal Cover
IEC line or load terminal covers for 201251 A devices.
Dead front protection

150-TC2

Terminal Cover
IEC line or load terminal covers for 317480 A devices.
Dead front protection

150-TC3

Human Interface Modules


LCD Display,
Full Numeric Keypad

20-HIM-A3

LCD Display,
Programmer Only HIM

20-HIM-A5

Door Mounted
Human Interface Modules

LCD Display,
Full Numeric Keypad
(includes 3 m cable)

20-HIM-C3S

Human Interface Module


Interface Cables

HIM Interface Cable,


1 m (39 in.)

20-HIM-H10

Remote I/O

20-COMM-R

Hand Held
Human Interface Modules

Communication Modules

Communication Modules (IP30/Type 1)

RS-485/DF1

20-COMM-S

ProfiBUS

20-COMM-P

ControlNet

20-COMM-C

Interbus

20-COMM-I

DeviceNet

20-COMM-D

Ethernet/IP

20-COMM-E

RS-485 HVAC

20-COMM-H

ControlNet (Fiber)

20-COMM-Q

100:1

825-CBCT

Core Balance Transformer


Core Balance Ground Fault Sensor

 The same protective module mounts on the line or load side of the SMC-Flex. For applications requiring both line and load side protection, two protective modules must be ordered.
 One terminal cover is shipped as standard with the SMC-Flex controllers.
Requires a 20-HIM-H10 cable to connect to the SMC-Flex.
Discount Schedule SOF (150-), Discount Schedule 23 (20-), Discount Schedule MPC (825-CBCT)

16

17

ARMORSTART
Bulletin 280/281
On-Machine starting solution
Full-Voltage DOL and reversing starting
Modular plug and play design
Quick disconnect connections for I/O, communications,
three phase motor connection and control power

Gland plate entry: conduit entrance or ArmorConnect power media


4 Inputs and 2 Outputs (expandable with ArmorPoint)
LED status indication
DeviceNet communications
DeviceLogix component technology
Connectivity to ArmorPoint distributed I/O products
ControlNet and EtherNet communications via ArmorPoint
Factory Installed Options:
- Hand/Off/Auto (HOA) keypad configuration
- Safety monitor

Conduit Entrance for Control and 3-Phase Power, 3 m unshielded cordset male 90 Motor Cable
Current Rating

Max.
Motor Power

24V DC
Control Voltage

[A]

[kW]
400V AC
50 Hz

DeviceNet
Communications
Cat. No.

ArmorPoint
Communications
Cat. No.

DeviceNet
Communications
Cat. No.

ArmorPoint
Communications
Cat. No.

0.241.2

0.37

280D-F12Z-10A-CR

280A-F12Z-10A-CR

280D-F12B-10A-CR

280A-F12B-10A-CR

0.52.5

0.75

280D-F12Z-10B-CR

280A-F12Z-10B-CR

280D-F12B-10B-CR

280A-F12B-10B-CR

1.15.5

2.2

280D-F12Z-10C-CR

280A-F12Z-10C-CR

280D-F12B-10C-CR

280A-F12B-10C-CR

3.216

7.5

280D-F23Z-25D-CR

280A-F23Z-25D-CR

280D-F23B-25D-CR

280A-F23B-25D-CR

TM

240V AC
Control Voltage
TM

Version with quick disconnects for ArmorConnect power media for Control and 3-Phase Power:
Replace -CR at the end of the Cat. No. with -RR (Example: 280D-F23Z-25D-RR)

for harsh production environments


Conduit Entrance for Control and 3-Phase Power, 3 m unshielded cordset male 90 Motor Cable
Current Rating

Max.
Motor Power

24V DC
Control Voltage

[A]

[kW]
400V AC
50 Hz

DeviceNet
Communications
Cat. No.

ArmorPoint
Communications
Cat. No.

DeviceNet
Communications
Cat. No.

ArmorPoint
Communications
Cat. No.

0.241.2

0.37

280D-S12Z-10A-CR

280A-S12Z-10A-CR

280D-S12B-10A-CR

280A-S12B-10A-CR

0.52.5

0.75

280D-S12Z-10B-CR

280A-S12Z-10B-CR

280D-S12B-10B-CR

280A-S12B-10B-CR

1.15.5

2.2

280D-S12Z-10C-CR

280A-S12Z-10C-CR

280D-S12B-10C-CR

280A-S12B-10C-CR

3.216

7.5

280D-S23Z-25D-CR

280A-S23Z-25D-CR

280D-S23B-25D-CR

280A-S23B-25D-CR

TM

Version with quick disconnects for ArmorConnect power media for Control and 3-Phase Power:
Replace -CR at the end of the Cat. No. with -RR (Example: 280D-S23Z-25D-RR)

18

240V AC
Control Voltage
TM

Conduit Entrance for Control and 3-Phase Power, 3 m unshielded cordset male 90 Motor Cable
Current Rating

Max.
Motor Power

24V DC
Control Voltage

240V AC
Control Voltage

[A]

[kW]
400V AC
50 Hz

0.241.2

0.37

281D-F12Z-10A-CR

281A-F12Z-10A-CR

281D-F12B-10A-CR

281A-F12B-10A-CR

0.52.5

0.75

281D-F12Z-10B-CR

281A-F12Z-10B-CR

281D-F12B-10B-CR

281A-F12B-10B-CR

1.15.5

2.2

281D-F12Z-10C-CR

281A-F12Z-10C-CR

281D-F12B-10C-CR

281A-F12B-10C-CR

3.216

7.5

281D-F23Z-25D-CR

281A-F23Z-25D-CR

281D-F23B-25D-CR

281A-F23B-25D-CR

ArmorPoint
Communications
Cat. No.

DeviceNet
Communications
Cat. No.
TM

DeviceNet
Communications
Cat. No.
TM

ArmorPoint
Communications
Cat. No.

Version with quick disconnects for ArmorConnect power media for Control and 3-Phase Power:
Replace -CR at the end of the Cat. No. with -RR (Example: 281D-F23Z-25D-RR)

for harsh production environments


Conduit Entrance for Control and 3-Phase Power, 3 m unshielded cordset male 90 Motor Cable
Current Rating

Max.
Motor Power

24V DC
Control Voltage

240V AC
Control Voltage

[A]

[kW]
400V AC
50 Hz

0.241.2

0.37

281D-S12Z-10A-CR

281A-S12Z-10A-CR

281D-S12B-10A-CR

281A-S12B-10A-CR

0.52.5

0.75

281D-S12Z-10B-CR

281A-S12Z-10B-CR

281D-S12B-10B-CR

281A-S12B-10B-CR

1.15.5

2.2

281D-S12Z-10C-CR

281A-S12Z-10C-CR

281D-S12B-10C-CR

281A-S12B-10C-CR

3.216

7.5

281D-S23Z-25D-CR

281A-S23Z-25D-CR

281D-S23B-25D-CR

281A-S23B-25D-CR

ArmorPoint
Communications
Cat. No.

DeviceNet
Communications
Cat. No.
TM

DeviceNet
Communications
Cat. No.
TM

ArmorPoint
Communications
Cat. No.

Version with quick disconnects for ArmorConnect power media for Control and 3-Phase Power:
Replace -CR at the end of the Cat. No. with -RR (Example: 281D-S23Z-25D-RR)

Cat. No.
Modification

Description

Example: 281D-S23Z-25D-RR-3

Hand Off-Auto Selector Keypad

-3

Hand Off-Auto Selector Keypad


with Forward/Reverse Function

-3FR

Example: 281D-S23Z-25D-RR-3FR

Safety Monitor

-SM

Example: 281D-S23Z-25D-RR-3FR-SM

For factory installed options, please contact your local sales office.
Other ArmorStart versions available.
Please consult publication 280-SG001_-EN-P for complete product information.

19

ARMORSTART
Bulletin 283
On-Machine starting solution
Soft Start motor control
Modular plug and play design
Quick disconnect connections for I/O, communications,
three phase motor connection and control power

Gland plate entry: conduit entrance or ArmorConnect power media


4 inputs and 2 outputs (expandable with ArmorPoint)
LED status indication
DeviceNet communications
DeviceLogix component technology
Connectivity to ArmorPoint distributed I/O products
ControlNet and EtherNet communications via ArmorPoint
Factory Installed Options:
- Hand/Off/Auto (HOA) keypad configuration
- Source brake contactor
- Safety monitor

Conduit Entrance for Control and 3-Phase Power, 3 m unshielded cordset male 90 Motor Cable
Current Rating

Max.
Motor Power

24V DC
Control Voltage

[A]

[kW]
400V AC
50 Hz

DeviceNet
Communications
Cat. No.

ArmorPoint
Communications
Cat. No.

DeviceNet
Communications
Cat. No.

ArmorPoint
Communications
Cat. No.

1.1...3.0

1.1

283D-FB3Z-10A-CR

283A-FB3Z-10A-CR

283D-FB3B-10A-CR

283A-FB3B-10A-CR

3.0...5.5

2,2

283D-FB9Z-10B-CR

283A-FB9Z-10B-CR

283D-FB9B-10B-CR

283A-FB9B-10B-CR

5.5...7.6

3.0

283D-FB16Z-10C-CR

283A-FB16Z-10C-CR

283D-FB16B-10C-CR

283A-FB16B-10C-CR

6.316

5.5

283D-FB19Z-25D-CR

283A-FB19Z-25D-CR

283D-FB19B-25D-CR

283A-FB19B-25D-CR

TM

240V AC
Control Voltage
TM

Version with quick disconnects for ArmorConnect power media for Control and 3-Phase Power:
Replace -CR at the end of the Cat. No. with -RR (Example: 283D-FB19Z-25D-RR)

for harsh production environments


Conduit Entrance for Control and 3-Phase Power, 3 m unshielded cordset male 90 Motor Cable
Current Rating

Max.
Motor Power

24V DC
Control Voltage

[A]

[kW]
400V AC
50 Hz

1.1...3.0

1.1

283D-SB3Z-10A-CR

283A-SB3Z-10A-CR

283D-SB3B-10A-CR

283A-SB3B-10A-CR

3.0...5.5

2,2

283D-SB9Z-10B-CR

283A-SB9Z-10B-CR

283D-SB9B-10B-CR

283A-SB9B-10B-CR

5.5...7.6

3.0

283D-SB16Z-10C-CR

283A-SB16Z-10C-CR

283D-SB16B-10C-CR

283A-SB16B-10C-CR

6.316

5.5

283D-SB19Z-25D-CR

283A-SB19Z-25D-CR

283D-SB19B-25D-CR

283A-SB19B-25D-CR

ArmorPoint
Communications
Cat. No.

DeviceNet
Communications
Cat. No.
TM

Version with quick disconnects for ArmorConnect power media for Control and 3-Phase Power:
Replace -CR at the end of the Cat. No. with -RR (Example: 283D-SB19Z-25D-RR)

20

240V AC
Control Voltage
DeviceNet
Communications
Cat. No.
TM

ArmorPoint
Communications
Cat. No.

Conduit Entrance for Control and 3-Phase Power, 3 m unshielded cordset male 90 Motor Cable
Current Rating

Max.
Motor Power

24V DC
Control Voltage

240V AC
Control Voltage

[A]

[kW]
400V AC
50 Hz

1.1...3.0

1.1

283D-FC3Z-10A-CR

283A-FC3Z-10A-CR

283D-FC3B-10A-CR

283A-FC3B-10A-CR

3.0...5.5

2,2

283D-FC9Z-10B-CR

283A-FC9Z-10B-CR

283D-FC9B-10B-CR

283A-FC9B-10B-CR

5.5...7.6

3.0

283D-FC16Z-10C-CR

283A-FC16Z-10C-CR

283D-FC16B-10C-CR

283A-FC16B-10C-CR

6.316

5.5

283D-FC19Z-25D-CR

283A-FC19Z-25D-CR

283D-FC19B-25D-CR

283A-FC19B-25D-CR

ArmorPoint
Communications
Cat. No.

DeviceNet
Communications
Cat. No.
TM

ArmorPoint
Communications
Cat. No.

DeviceNet
Communications
Cat. No.
TM

Version with quick disconnects for ArmorConnect power media for Control and 3-Phase Power:
Replace -CR at the end of the Cat. No. with -RR (Example: 283D-FC19Z-25D-RR)

for harsh production environments


Conduit Entrance for Control and 3-Phase Power, 3 m unshielded cordset male 90 Motor Cable
Current Rating

Max.
Motor Power

24V DC
Control Voltage

240V AC
Control Voltage

[A]

[kW]
400V AC
50 Hz

1.1...3.0

1.1

283D-SC3Z-10A-CR

283A-SC3Z-10A-CR

283D-SC3B-10A-CR

283A-SC3B-10A-CR

3.0...5.5

2,2

283D-SC9Z-10B-CR

283A-SC9Z-10B-CR

283D-SC9B-10B-CR

283A-SC9B-10B-CR

5.5...7.6

3.0

283D-SC16Z-10C-CR

283A-SC16Z-10C-CR

283D-SC16B-10C-CR

283A-SC16B-10C-CR

6.316

5.5

283D-SC19Z-25D-CR

283A-SC19Z-25D-CR

283D-SC19B-25D-CR

283A-SC19B-25D-CR

ArmorPoint
Communications
Cat. No.

DeviceNet
Communications
Cat. No.
TM

ArmorPoint
Communications
Cat. No.

DeviceNet
Communications
Cat. No.
TM

Version with quick disconnects for ArmorConnect power media for Control and 3-Phase Power:
Replace -CR at the end of the Cat. No. with -RR (Example: 283D-SC19Z-25D-RR)

Description

Cat. No.
Modification

Hand Off-Auto Selector Keypad

-3

Example: 283D-SC19Z-25D-RR-3

Source Brake Contactor

-SB

Example: 283D-SC19Z-25D-RR-3-SB

Safety Monitor

-SM

Example: 283D-SC19Z-25D-RR-3-SB-SM

For factory installed options, please contact your local sales office.
Other ArmorStart versions available.
Please consult publication 280-SG001_-EN-P for complete product information.

21

ARMORSTART
Bulletin 284
On-Machine starting solution
Variable frequency AC drive using PowerFlex technology
Modular plug and play design
Quick disconnect connections for I/O, communications,
three phase motor connection and control power

Gland plate entry: conduit entrance or ArmorConnect power media


4 Inputs and 2 Outputs (expandable with ArmorPoint)
LED status indication
DeviceNet communications
DeviceLogix component technology
Connectivity to ArmorPoint distributed I/O products
ControlNet and EtherNet communications via ArmorPoint
Factory Installed Options:
- Hand/Off/Auto (HOA) keypad configuration
- EMI filter
- Dynamic brake connector
- Output contactor
- Source brake contactor
- Shielded motor cable
- Safety monitor
- 0...10V analog input

Sensorless Vector Control and Volts per Hertz, with DeviceNet Communications,
EMI-Filter, Conduit Entrance for Control and 3-Phase Power, 3 m unshielded cordset male 90 Motor Cable

Input Voltage
200...240V, 50/60 Hz
3-Phase

380...480V, 50/60 Hz
3-Phase

460600V, 50/60 Hz
3-Phase

Output Current
[A]

3-Phase Rating
[kW]

24V DC
Control Voltage

240V AC
Control Voltage

Cat. No.

Cat. No.

2.3

0.4

284D-FVB2P3Z-10-CR-EMI

284D-FVB2P3B-10-CR-EMI

0.75

284D-FVB5P0Z-10-CR-EMI

284D-FVB5P0B-10-CR-EMI

7.6

1.5

284D-FVB7P6Z-25-CR-EMI

284D-FVB7P6B-25-CR-EMI

1.4

0.4

284D-FVD1P4Z-10-CR-EMI

284D-FVD1P4B-10-CR-EMI

2.3

0.75

284D-FVD2P3Z-10-CR-EMI

284D-FVD2P3B-10-CR-EMI

1.5

284D-FVD4P0Z-10-CR-EM

284D-FVD4P0B-10-CR-EMI

2.2

284D-FVD6P0Z-25-CR-EMI

284D-FVD6P0B-25-CR-EMI

7.6

284D-FVD7P6Z-25-CR-EMI

284D-FVD7P6B-25-CR-EMI

1.7

0.75

284D-FVE1P7Z-10-CR-EMI

284D-FVE1P7B-10-CR-EMI

1.5

284D-FVE3P0Z-10-CR-EMI

284D-FVE3P0B-10-CR-EMI

4.2

2.2

284D-FVE4P2Z-25-CR-EMI

284D-FVE4P2B-25-CR-EMI

6.1

284D-FVE6P6Z-25-CR-EMI

284D-FVE6P6B-25-CR-EMI

Version with ArmorPoint Communications:


Replace 284D at the beginning of the Cat. No. with 284A (Example: 284A-FVE6P6Z-25-CR-EMI)
Version with Quick Disconnects for ArmorConnect Power Media for Control and 3-Phase Power:
Replace -CR at the end of the Cat. No. with -RR (Example: 284D-FVE6P6Z-25-RR-EMI)

22

Sensorless Vector Control and Volts per Hertz, with DeviceNet Communications,
EMI-Filter, Conduit Entrance for Control and 3-Phase Power, 3 m unshielded cordset male 90 Motor Cable

Input Voltage

24V DC
Control Voltage

240V AC
Control Voltage

Output Current
[A]

3-Phase Rating
[kW]

Cat. No.

Cat. No.

2.3

0.4

284D-SVB2P3Z-10-CR-EMI

284D-SVB2P3B-10-CR-EMI

0.75

284D-SVB5P0Z-10-CR-EMI

284D-SVB5P0B-10-CR-EMI

7.6

1.5

284D-SVB7P6Z-25-CR-EMI

284D-SVB7P6B-25-CR-EMI

1.4

0.4

284D-SVD1P4Z-10-CR-EMI

284D-SVD1P4B-10-CR-EMI

2.3

0.75

284D-SVD2P3Z-10-CR-EMI

284D-SVD2P3B-10-CR-EMI

1.5

284D-SVD4P0Z-10-CR-EMI

284D-SVD4P0B-10-CR-EMI

200...240V, 50/60 Hz
3-Phase

380...480V, 50/60 Hz
3-Phase

460600V, 50/60 Hz
3-Phase

2.2

284D-SVD6P0Z-25-CR-EMI

284D-SVD6P0B-25-CR-EMI

7.6

284D-SVD7P6Z-25-CR-EMI

284D-SVD7P6B-25-CR-EMI

1.7

0.75

284D-SVE1P7Z-10-CR-EMI

284D-SVE1P7B-10-CR-EMI

1.5

284D-SVE3P0Z-10-CR-EMI

284D-SVE3P0B-10-CR-EMI

4.2

2.2

284D-SVE4P2Z-25-CR-EMI

284D-SVE4P2B-25-CR-EMI

6.1

284D-SVE6P6Z-25-CR-EMI

284D-SVE6P6B-25-CR-EMI

Version with ArmorPoint Communications:


Replace 284D at the beginning of the Cat. No. with 284A (Example: 284A-SVE6P6Z-25-CR-EMI)
Version with Quick Disconnects for ArmorConnect Power Media for Control and 3-Phase Power:
Replace -CR at the end of the Cat. No. with -RR (Example: 284D-SVE6P6Z-25-RR-EMI)

Description

Cat. No.
Modification

Hand Off-Auto Selector Keypad


with JOG Function

-3

Example: 284D-SVE6P6Z-25-CR-3-EMI

Control Brake Contactor

-CB

Example: 284D-SVE6P6Z-25-CR-3-CB-EMI

Dynamic Brake Connector

-DB

Example: 284D-SVE6P6Z-25-CR-3-DB-EMI

Source Brake Contactor

-SB

Example: 284D-SVE6P6Z-25-CR-3-SB-EMI

0...10V Analog Input

-A10

Example: 284D-SVE6P6Z-25-CR-3-SB-A10

EMI Filter

-EMI

Example: 284D-SVE6P6Z-25-CR-3-SB-EMI

Output Contactor

-OC

Example: 284D-SVE6P6Z-25-CR-3-SB-OC

-SM 

Example: 284D-SVE6P6Z-25-CR-3-SB-SM

Safety Monitor
 The output contactor is included with the Safety Monitor option.
For factory installed options, please contact your local sales office.

23

SHORT

Motor

Direct-Online Class 10
Circuit Breaker 140M MCP (Magnetic Only)
Contactor 100-C / 100-D
Overload Relay E1Plus - 193-ED../193-EE..
Rated Operational Voltage 400V 50Hz
Rated Conditional S-C Current (Iq) 50kA (rms sym)
Type of Coordination (IEC 947-4-1) Type "2"

Circuit Breaker

Contactor

1500 rpm
[kW]

[A]

Type

Magnetic
Setting
[A]

0.06
0.09
0.12
0.18
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3
4
5.5
7.5
10
11
15
18.5
22
30
37
45
55
75
90
110
132
160
200

0.24
0.33
0.43
0.61
0.80
1.1
1.5
1.9
2.7
3.5
5.0
6.6
8.5
11
15
20
22
29
36
41
56
68
81
99
135
162
196
232
281
350

140M-C2N-A25
140M-C2N-A40
140M-C2N-A63
140M-C2N-A63
140M-C2N-B10
140M-C2N-B16
140M-C2N-B16
140M-C2N-B25
140M-D8N-B40
140M-D8N-B40
140M-D8N-B63
140M-D8N-C10
140M-D8N-C10
140M-D8N-C16
140M-D8N-C16
140M-D8N-C25
140M-D8N-C25
140M-F8N-C32
140M-F8N-C45
140M-F8N-C45
140M-H8P-C70
140M-H8P-C70
140M-H8P-D10
140M-H8P-D10
140M-J8P-D20
140M-J8P-D20
140M-J8P-D20
140M-J8P-D25
140M-L8P-D30
140M-L8P-D40

3.3
5.2
8.2
8.2
13
20
20
32
52
52
82
130
130
208
208
325
325
416
585
585
210 - 770
210 - 770
300 - 1100
300 - 1100
1000 - 2000
1000 - 2000
1000 - 2000
1250 - 2500
1500 - 3000
2000-4000

(1) Use of current ajustment shield 193-BC8 is recommended to prevent inadvertent adjustment of the current setting

24

Overload Relay

Type

Type (1)

Thermal
Setting
[A]

100-C09
100-C09
100-C09
100-C09
100-C09
100-C09
100-C09
100-C09
100-C09
100-C09
100-C09
100-C09
100-C09
100-C12
100-C16
100-C23
100-C23
100-C30
100-C37
100-C43
100-C60
100-C72
100-C85
100-D210
100-D210
100-D210
100-D210
100-D250
100-D300
100-D420

193-ED1AB
193-ED1AB
193-ED1AB
193-ED1BB
193-ED1BB
193-ED1CB
193-ED1CB
193-ED1CB
193-ED1CB
193-ED1CB
193-ED1CB
193-ED1DB
193-ED1DB
193-ED1DB
193-ED1DB
193-EEED
193-EEED
193-EEFD
193-EEFD
193-EEFD
193-EEFD
193-EEGE
193-EEGE
193-EEJG
193-EEJG
193-EEJG
193-EEJG
193-EEKG
193-EEKG
193-EELG

0.10 - 0.50
0.10 - 0.50
0.10 - 0.50
0.20 - 1.0
0.20 - 1.0
1.0 - 5.0
1.0 - 5.0
1.0 - 5.0
1.0 - 5.0
1.0 - 5.0
1.0 - 5.0
3.2 - 16
3.2 - 16
3.2 - 16
3.2 - 16
5.4 - 27
5.4 - 27
9 - 45
9 - 45
9 - 45
9 - 45
18 - 90
18 - 90
40 - 200
40 - 200
40 - 200
40 - 200
60 - 300
60 - 300
100 - 500

SHORT

Motor

Direct-Online Class 10
Circuit Breaker 140M MCP (Magnetic Only)
Contactor 100-C / 100-D
Overload Relay E3 - 193-EC1 / 193-EC2
Rated Operational Voltage 400V 50Hz
Rated Conditional S-C Current (Iq) 50kA (rms sym)
Type of Coordination (IEC 947-4-1) Type "2"

Circuit Breaker

1500 rpm
[kW]

[A]

0.06
0.09
0.12
0.18
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3
4
5.5
7.5
10
11
15
18.5
22
30
37
45
55
75
90
110
132
160
200

0.24
0.33
0.43
0.61
0.80
1.1
1.5
1.9
2.7
3.5
5.0
6.6
8.5
11
15
20
22
29
36
41
56
68
81
99
135
162
196
232
281
350

Contactor

Overload Relay

Type

Magnetic
Setting
[A]

Type

Type (1) (2)

Thermal
Setting
[A]

140M-C2N-A25
140M-C2N-A40
140M-C2N-A63
140M-C2N-A63
140M-C2N-B10
140M-C2N-B16
140M-C2N-B16
140M-C2N-B25
140M-D8N-B40
140M-D8N-B40
140M-D8N-B63
140M-D8N-C10
140M-D8N-C10
140M-D8N-C16
140M-D8N-C16
140M-D8N-C25
140M-D8N-C25
140M-F8N-C32
140M-F8N-C45
140M-F8N-C45
140M-H8P-C70
140M-H8P-C70
140M-H8P-D10
140M-H8P-D10
140M-J8P-D15
140M-J8P-D20
140M-J8P-D20
140M-J8P-D25
140M-L8P-D30
140M-L8P-D40

3.3
5.2
8.2
8.2
13
20
20
32
52
52
82
130
130
208
208
325
325
416
585
585
210 - 770
210 - 770
300 - 1100
300 - 1100
750 - 1500
1000 - 2000
1000 - 2000
1250 - 2500
1500 - 3000
2000-4000

100-C09
100-C09
100-C09
100-C09
100-C09
100-C09
100-C09
100-C09
100-C09
100-C09
100-C09
100-C09
100-C09
100-C12
100-C16
100-C23
100-C23
100-C30
100-C37
100-C43
100-C60
100-C72
100-C85
100-D110
100-D140
100-D180
100-D210
100-D250
100-D300
100-D420

193-EC1PB
193-EC1PB
193-EC1PB
193-EC1PB
193-EC1PB
193-EC1PB
193-EC1PB
193-EC1PB
193-EC1AB
193-EC1AB
193-EC1AB
193-EC1BB
193-EC1BB
193-EC1BB
193-EC1BB
193-EC1CB
193-EC1CB
193-EC1DD
193-EC1DD
193-EC1DD
193-EC1EE
193-EC1EE
193-EC1EE
193-EC1FF
193-EC1FF
193-EC1GF
193-EC1GG
193-EC1HG
193-EC1HG
193-EC1JG

0.4 - 2.0
0.4 - 2.0
0.4 - 2.0
0.4 - 2.0
0.4 - 2.0
0.4 - 2.0
0.4 - 2.0
0.4 - 2.0
1-5
1-5
1-5
3 - 15
3 - 15
3 - 15
3 - 15
5 - 25
5 - 25
9 - 45
9 - 45
9 - 45
18 - 90
18 - 90
18 - 90
28 - 140
28 - 140
42 - 210
42 - 210
60 - 302
60 - 302
84 - 420

(1) Use of current ajustment shield 193-BC8 is recommended to prevent inadvertent adjustment of the current setting

25

(2) Overload Relay 193-EC2.. can also be used

Motor Protection
Overload
Underload
Stall
Jam
Thermistor Input
Earth Fault Input
Phase loss
Current Imbalance
Short Circuit
Phase Reversal
Under Voltage
Over Voltage
Starts Per Hour
2 Speed Motor
Stator RTD
Bearing RTD
Ambient RTD
Trip class
Manual reset
Automatic reset
Single phase
Three phase
Warnings
Fault History
General Features
Communication
Logic Functions
Local display
I/O
Soft Starter Control
Soft Start
Kick Start
Curent Limit
Dual ramp Start
Full Voltage
Soft Stop
Pump Control
Preset Slow Speed
Linear Speed
Braking
Accu-Stop
Slow Speed with Braking
Suitable for inside the delta wiring
Variable Speed Control
Variable Speed
Flying Start
S - Curve
Process Control Loop (PID
Fast Flux Up
Fast Brake to Stop
Flux Braking
Speed Proles
Close Loop Speed Control
Close Loop Torque Control
P-jump (Traverse Function)
Pump/Fan Application Functions
Lifting Application Functions
Winder Application Functions
Electronic Gearing/Line Shaft
Motion Control Functions
Safe-Off
Mechanical Protection
Overall Vibration level
Unbalance
Misalignment
Flow problems
Bearing Defects
Mechanical Looseness
Rubbing
Drive Belt Problems

193-ED

10

193-EE

(1)
(1)
(1)
(1)

193-EC1

193-EC2

5...30

5...30

(1)

10...30

825-P

(1)
(1)

(1)
(1)
(1)
1...600

SMC-3

5...30

26

SMC-FLEX

PF4M

PF4

PF40

PF40P

PF400

PF70

PF700

PF700H

PF700S

NA
regulated

NA
regulated

NA
regulated

NA
regulated

NA
regulated

NA
regulated

NA
regulated

NA
regulated

NA
regulated

regulated

regulated

regulated

regulated

regulated

regulated

regulated

regulated

regulated

no limits
NA

no limits
NA

no limits
NA

no limits
NA

no limits
NA

no limits
NA

no limits
NA

no limits
NA

no limits
NA

variable

variable

variable

variable

variable

variable

variable

variable

variable

(1)

(1)

(1)

(1)
(1)

(1)

(1)

(1) With add on Modules.

27

XM-16X

XM-12X

(1)

(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)

(1)

(1)

28

29

Rockwell Automation Services & Support


Assessment Services

PREDICT

Baseline evaluations of plant floor technical skills, procedures, equipment operation, spare parts inventory, risk,
safety and security as well as other automation-related assessments.
Condition Monitoring
Predictive Maintenance products and services for rotating equipment.
Asset Management Services
Maintenance Repair Operations (MRO) process and Spare Parts Management for automation assets.
Remote Support Services
Real-time troubleshooting and monitoring* of automation equipment and systems by off-site automation
specialists.

PREVENT

Safety, Network & Security Services


Network design and evaluation, security policy development/deployment, and machine safety services.
Training Services
Instructor-led training, self-paced training and competency testing on automation and related topics.
OnSite Support Services
Startup, troubleshooting, repair, conversions and Preventive Maintenance for automation equipment and
systems by Rockwell Automation Field Support Engineers.

REACT

Repair Services & Renewal Parts


Remanufacturing and exchange services for automation products and
build-to-order legacy automation products.
*System monitoring not available at all service levels

For More Information


For more information about Rockwell Automation Services and Support go to
www.rockwellautomation.com/services. To learn which other Rockwell Automation Services and
Support will be most beneficial to your maintenance strategy, contact your local authorised AllenBradley distributor or Rockwell Automation sales office.

Publication DOLSMC-SG001A-EN-P June 2007

Copyright 2007 Rockwell Automation, Inc. All Rights Reserved. Printed in Europe.

You might also like