You are on page 1of 29

Workshop 2.

2
14.5 Release

ANSYS Aqwa Hydrodynamic Time Response

2012 ANSYS, Inc.

June 11, 2013

Release 14.5

Time Domain Simulation


Open Workbench and open project using File > Open

Browse to MooredShip.wbpj

2012 ANSYS, Inc.

June 11, 2013

Release 14.5

Open Hydrodynamic System


Double click on Model cell in the Hydrodynamic System
This is a similar model to that used in Workshop 2.1 and has already been
solved.

Close the Hydrodynamic System

2012 ANSYS, Inc.

June 11, 2013

Release 14.5

Adding the time response

Drag and drop the Hydrodynamic Time Response to the WB Project Schematic while
sharing the solution from hydrodynamic diffraction
Double-click on Setup
2012 ANSYS, Inc.

June 11, 2013

Release 14.5

Add fairlead connection points


Add four fairlead locations for the mooring system
Under Geometry in the Outline select Mooring Ship > Add > Connection
Point
Enter X,Y,Z coordinates in details panel as below (in global system!)
Repeat for other 3 connection points

Point 2 20, -14.2, 8


Point 3 180, 16, 8
Point 4 180, -16, 8
Rename Connection Points as Fairlead 1 through 4

2012 ANSYS, Inc.

June 11, 2013

Release 14.5

Add anchor fixed points


Add four anchor locations for the mooring system
Under Model in the Outline select Geometry > Add > Fixed Point
Enter X,Y,Z coordinates in details panel as below
Repeat for other 3 fixed points

Point 2 -1000,-1000,-500
Point 3 1000,1000,-500
Point 4 1000,-1000,-500
Rename Fixed Points as Anchor 1 through 4

2012 ANSYS, Inc.

June 11, 2013

Release 14.5

Set up mooring line properties


We are going to use composite catenary lines for the mooring system. These
are lines made up of one or more segments with varying properties e.g.
chain/wire/chain

Select Connections > Catenary Data > Insert Catenary Data > Catenary
Section. Note we can also define intermediate buoys and/or clump weights.

2012 ANSYS, Inc.

June 11, 2013

Release 14.5

Mooring line properties


Provide data for Mass/Unit Length, Equivalent Cross Sectional Area, Stiffness,
Maximum Tension and Equivalent Diameter as below. Rename as LineProp1

Note we can also define bending stiffness, non-linear axial properties


Repeat for two additional sections

2012 ANSYS, Inc.

June 11, 2013

Release 14.5

Mooring line connections


To add a line select Connections > Insert Connection > Cable
Choose Fixed Point & Structure for Connectivity and Non-Linear Catenary for
Type
We need to define end connection points and the segments along the line,
plus some data defining the possible dZ range of the fairlead (explained in
Workshop 3.2).
Rename mooring line as Cable 1

2012 ANSYS, Inc.

June 11, 2013

Release 14.5

Mooring line connections


Click on cell adjacent to Fixed Point and select Anchor1 (Fixed) from drop
down menu.
Click on cell adjacent to End Connection Point and select Fairlead 1
(MooringShip) from drop down menu.

2012 ANSYS, Inc.

June 11, 2013

10

Release 14.5

Mooring line configuration


The composition of the line is now defined

Segment allocation
Line length
Segments are defined from the anchor location up to the fairlead
Section 1 type should be set to LineProp1
Length 400 m
Repeat for sections 2 and 3 as shown
Finally set the Positive dZ Range under Cable Properties to 10m

2012 ANSYS, Inc.

June 11, 2013

11

Release 14.5

Mooring line configuration


Repeat these steps for the other three lines

2012 ANSYS, Inc.

June 11, 2013

12

Release 14.5

Mooring line configuration


Note that as you construct the line configuration the line properties are
reported in a window called Catenary Cable Definition Data
The Joint 1-2 etc refers to connection data such as clump weights or buoys

2012 ANSYS, Inc.

June 11, 2013

13

Release 14.5

Mooring line configuration


Select Connections in the Outline to see the final mooring configuration

2012 ANSYS, Inc.

June 11, 2013

14

Release 14.5

Time domain simulation options


Set Analysis Type to regular wave response
Set Use Cable Dynamics to No
Set Convolution to No

Set Finish Time to 180 seconds

2012 ANSYS, Inc.

June 11, 2013

15

Release 14.5

Define the environment


RMB on Hydrodynamic Time
Response > Insert > Regular Wave

Set Wave Type to Airy Wave Theory


Set Amplitude to 1 m
Set Period to 10 s
Set Direction to 90 degrees
Run the analysis by clicking on
Solution and

2012 ANSYS, Inc.

June 11, 2013

16

Release 14.5

Check the solution


RMB Solution to Insert Result >
Structure Position > Actual
Response
Select the Global Z as the mode of
motion and generate the graph
(RMB Evaluate All Results)

2012 ANSYS, Inc.

June 11, 2013

17

Release 14.5

Check the solution


Add a second graph item -Insert
Result > Cable Forces > Whole Cable
Forces
Select Tension for Cables 1 and 3
Evaluate All Results

2012 ANSYS, Inc.

June 11, 2013

18

Release 14.5

Irregular wave simulation


RMB Regular Wave and Suppress

Change the Analysis Type in


Analysis Settings to Irregular
Wave Response and set
Convolution to Yes
RMB on Hydrodynamic Time
Response to Insert > Irregular
Wave Pierson-Moskowitz

2012 ANSYS, Inc.

June 11, 2013

19

Release 14.5

Set Irregular wave characteristics


Set Direction to 90 degrees
Set Seed to 10001 (this is used to
generate the random phase relationships
of the wave components)

Set Start Frequency to 0.1 rad/s


Set Finish Frequency to 2.0 rad/s
Set Significant Wave Height to 0.88 m
Set Zero Crossing Period to 10 s

2012 ANSYS, Inc.

June 11, 2013

20

Release 14.5

Set Analysis Settings and Solve


Set Finish Time to 1200 s
Run the analysis by clicking on
Solution and

2012 ANSYS, Inc.

June 11, 2013

21

Release 14.5

Setting up parameters
For design studies, several input parameters can be set as variable (such as
environmental parameters)
Click the square on the left hand side of the Significant Wave Height on the
Irregular Wave Details
P in the box will indicate that this value is a variable parameter and the
value input box will be locked

2012 ANSYS, Inc.

June 11, 2013

22

Release 14.5

...Setting up parameters
Go back to Project Schematic

You will see that the Parameter Set box has appeared. D-Click on the
Parameter Set box

2012 ANSYS, Inc.

June 11, 2013

23

Release 14.5

Design Points View


Design Points view in workbench consists of several sub-views;

Outline of all parameters


Table of design points
Properties
Chart
Parameters Chart Toolbox

2012 ANSYS, Inc.

June 11, 2013

24

Release 14.5

Setting up output parameters


Go back to the Aqwa window.
Select the Cable Forces Result
Set the maximum value of Line B as an
output parameter (this will enable
design point computations to be
automated)
Under Analysis Settings set Time Step
to 0.25 s and Finish Time to 600 s (will
reduce total solution time)

2012 ANSYS, Inc.

June 11, 2013

25

Release 14.5

Setting up output parameters


You will see in Outline of All Parameters window that this value is set as an
Output Parameter

2012 ANSYS, Inc.

June 11, 2013

26

Release 14.5

Setting up Design Points


Go to Table of Design Points
Input more periods as design points
Click

The solution will take several minutes, so be patient.

Note the Exported column. If one or more of these boxes are checked then the
results for that particular design point(s) will be saved. Otherwise only the initial
design point (marked as Current) is preserved.

2012 ANSYS, Inc.

June 11, 2013

27

Release 14.5

Results of Parameter Studies


You can observe the result of the outputs in tabular form in Table of Design
Points

2012 ANSYS, Inc.

June 11, 2013

28

Release 14.5

... Results of Parameter Studies


You can also plot them from the Parameter Charts Toolbox

Select Outline Of All Parameters to see the Toolbox


D-click on Parameters Chart
Select X axis and Y axis parameters from Properties of Outline
The resulting plot will be observed in Parameter Chart window (Note that line properties may be
modified by RMB on the line and select Edit Properties)

2012 ANSYS, Inc.

June 11, 2013

29

Release 14.5

You might also like