You are on page 1of 6

ODISHA POWER TRANSMISSION CORPORATION LIMITED

Name of the Work:-Construction of 132KV SC Line on DC tower from 132/33 KV, Kesinga Grid S/s to 132/33 KV, Junagarh Grid S/s with 132KV feeder bay extension at both S/s ends.(App. Line Length: 52.794Kms.)

PACKAGE 67(III)/2014-15

NOTICE INVITING TENDER-NIT NO. 67/2014-15


BID DOCUMENT No.:Sr. G.M- CPC- TENDER- PACKAGE- 67(III)/2014-15
PART-I SCHEDULE-2A (FOR SUBSTATION)(Equipment/Materials Supply Price Break-up of Ex-works Prices against PACKAGE: 67(III)/2014-15
NAME OF THE BIDDER
SUPPLY_ SUBSTATION EQUIPMENT/MATERIALS
S. No.

1
1
2
2.1
2.2
3
4
5
6
7
7.1
7.1.1

DESCRIPTION OF ITEMS
SUPPLY OF FOLLOWING EQUIPMENTS
(As per Technical Specification)

2
145 KV,800-400-200 A,31.5 KA,4CORE SINGLE PHASE CURRENT TRANSFORMER
145 KV,1200A,31.5KA,ISOLATORS
S/I WITH OUT EARTH SWITCH
D/I WITH SINGLE EARTH SWITCH
145 KV,6600pF,3CORE,SINGLE PHASE CAPACITOR VOLTAGE TRANSFORMER
120 KV METAL OXIDE SURGE ARRESTOR, 10 KA, Class III
132 KV Bus Post Insulators
145KV,3150A,40KA,SF6,CIRCUIT BREAKER WITH SUPPORTING STRUCTURE
BUS BAR & CIRCUIT MATERIALS
TENSION & SUSPENSION ANTI FOG TYPE INSULATOR STRING
120 kN ANTIFOG INSULATOR STRINGS for Double Moose cond (TENSION)-132 KV

UNITS

Quantity for:
construction of 1
no. 132 kV feeder
bay Extn. at
132/33kV
Kesinga SS

Quantity for:
Construction of
1no.132Kv Fdr.
Bay Extn. at
132/33KV SubStation at
Junagarh SS

Total Quantity

Unit Ex-Works Price


IN INR

Total Ex-Works Price


IN INR

Unit F&I Charges


IN INR

Total F&I Charges


IN INR

Mode of Transaction
(Direct or Bought-out
item)

Unit Excise duty


IN INR

Unit VAT
IN INR

Unit CST
in INR

Any other tax


IN INR

Total Taxes and duties


IN INR

Unit FORD Price


IN INR

TOTAL FORD Price


IN INR

7.00

8=7X6

9.00

10=9X6

11

12

13

14

15

NOS

NOS
NOS

1
1

1
1

16= 12+13+14+15

17=7+9+12+13+14+15

18=17X6

0.00

0.00

0.00

0.00

0.00

2
2

0.00
0.00

0.00
0.00

0.00
0.00

0.00
0.00

NOS

0.00
0.00

0.00

0.00

0.00

0.00

NOS
NOS

3
2

3
2

0.00

6
4

0.00
0.00

0.00
0.00

0.00
0.00

0.00
0.00

NOS

0.00
0.00

0.00

0.00

0.00

0.00

SET

0.00

12

0.00

0.00

0.00

0.00

SET

12

0.00

12

24

0.00

0.00

0.00

0.00

0.00

120 kN ANTIFOG INSULATOR STRINGS for Single Moose cond ( TENSION)-132 KV


7.1.2
7.1.3

90 kN ANTIFOG INSULATOR STRINGS


SUSPENSION)-132 KV
ACSR MOOSE CONDUCTOR

for Double/ Single Moose cond (

SET

18

0.00

0.00

0.00

0.00

0.00

KMS

0.5

0.5

0.00

0.00

0.00

0.00

0.00

LOT

0.00

0.00

0.00

0.00

0.00

SETS

0.00

0.00

0.00

0.00

0.00

MTRS

700

700

1400

0.00

0.00

0.00

0.00

0.00

MTRS

450

450

900

0.00

0.00

0.00

0.00

0.00

MTRS

25

25

50

0.00

0.00

0.00

0.00

0.00

MTRS

25

25

50

0.00

0.00

0.00

0.00

0.00

section 1-1

MTRS

80

80

160

0.00

0.00

0.00

0.00

0.00

Section 2-2
'7.5.5.3 Section 3-3
'7.5.5.4 section 4-4

MTRS

70

70

140

0.00

0.00

0.00

0.00

0.00

MTRS

50

50

100

0.00

0.00

0.00

0.00

0.00

MTRS

0.00

0.00

0.00

0.00

0.00

NOS
NOS

1
2

1
2

2
4

0.00
0.00

0.00
0.00

0.00
0.00

0.00
0.00

0.00
0.00

NOS
NOS

2
1

2
1

4
2

NOS
NOS
MT

2
2
6.41

2
2
6.41

4
4
12.82

7.2
7.3

7.4
7.5
7.5.1
7.5.2
7.5.3
7.5.4

7.5.5
'7.5.5.1

HARDWARES & FITTINGS/SPACERS/CLAMP & CONNECTORS


EARTHING SPIKE & IT'S FITTING to be fixed on the Tower column as per OPTCL
standard(50 NB Heavy Gauge 7 mtrs long GI pipe & accessories & 2 Nos 65 NB 50
SUBSTATION EARTHING SYSTEMS
EARTHING CONDUCTOR FOR BURRIAL : 75X10 mm GI Flat for laying (spacing
maximum 5m both way )
EARTHING CONDUCTOR: 50X6 mm GI Flat for Raiser from the burial earth mat to
equipment,structure etc)
EARTHING DEVICE & ASSOCIATED ACCESSORIES (50 mm heavy duty GI
PERFORATED PIPE 3 mtrs long for treated earth pit)
EARTHING DEVICE & ASSOCIATED ACCESSORIES 40mm MS rod 3 mtrs long for non
treated earth pit)
G.I Cable Trays including support GI angle suitable for different sections i.e. Section:1-1,2-2,33 & 4-4 along with its accessories in complete shape as per TS.

'7.5.5.2

7.6

SUB STATION SWITCHYARD BMK,AC CONSOLE & OTHER MARSHALLING BOXES

7.6.1
7.6.3

0.00

0.00

0.00

0.00

0.00

SET
SET
SET
SET
SET
SET
MT
MT

2
3
3
3
2
2
5.382
1

2
3
3
3
2
2
5.382
1

4
6
6
6
4
4
10.764
2

0.00
0.00

0.00
0.00

0.00
0.00

0.00
0.00

0.00
0.00

9.1.3

BAY MARSHALLING KIOSK (01 No 132 kv bay )


CT & CVT Out Door Console Boxes
SWITCH YARD STRUCTURES (LATTICE TYPE) FOR 220/132/33 KV CLASS
INCLUDING FOUNDATION BOLTS & NUTS.
DIFFERENT TYPES OF COLUMNS WITH DETAILS
T1S - 132 KV(NOMINAL UNIT WT- 1.2 MT)
T4S - 132KV (NOMINAL UNIT WT- 0.95 MT)
DIFFERENT TYPE OF BEAMS WITH DETAILS
G1 - 132 KV(NOMINAL UNIT WT- 0.62 MT)
G2 - 132 KV(NOMINAL UNIT WT- 0.91 MT)
TOTAL WEIGHT OF COLUMN & BEAM
SUPPORT STRUCTURES (LATTICE/PIPE TYPE) FOR ALL 132 KV & 33KV
EQUIPMENTS
ISOLATORS-132KV
CTS-132 KV
CVTS-132 KV
Surge Arrester-132 kV
Wave Trap-132 KV
BPI-132 KV
TOTAL WEIGHT OF EQUIPMENT STRUCTURE
Total weight of GI Nuts and bolts for the above structures
GENERAL EQUIPMENT & SUBSTATION ACCESSORIES
POWER CABLES,1.1KV,PVC/XLPE,ARMOURED, ALUMINIUM CONDUCTOR (As
per Specification)
PVC 3.5 CX35 mm2

MTRS

250

250

500

0.00

0.00

0.00

0.00

0.00

9.1.4

PVC 4 CX 6 mm2

MTRS

250

250

500

0.00

0.00

0.00

0.00

0.00

9.1.5

PVC 2CX 6 mm2


CONTROL CABLES,1.1 KV, PVC,STRANDED COPPER(As per specification)

MTRS

200

200

400

0.00

0.00

0.00

0.00

0.00

9.2.1
9.2.2

2 CX 2.5 mm2
4 CX 2.5 mm

MTRS
MTRS

500
2500

500
2500

1000
5000

0.00
0.00

0.00
0.00

0.00
0.00

0.00
0.00

0.00
0.00

9.2.3

5 CX 2.5 mm

0.00

0.00

0.00

9.2.4

7CX 2.5 mm2

9.2.5

10 CX 2.5 mm

9.2.6

12 CX 2.5 mm
ACCESSORIES FOR PLCC SYSTEM AS PER TECHNICAL SPECIFICATION

8
8.1
8.1.1
8.1.2
8.2
8.2.1
8.2.2
8.3
8.4
8.4.1
8.4.3
8.4.5
8.4.8
8.4.9
8.4.10
8.5
8.6
9
9.1

9.2

500
500

0.00

0.00

MTRS

500
500

1000
1000

0.00

0.00

0.00

0.00

0.00

MTRS

1000

1000

2000

0.00

0.00

0.00

0.00

0.00

MTRS

1000

1000

2000

0.00

0.00

0.00

0.00

0.00

10.1

132 kV Line Trap for Pedestal mounting with complete accessories :1200A, 0.5 mH, (90500kHZ),Isc=31.5kA compatible to IEC 353 specifications

NOS

0.00

0.00

0.00

0.00

0.00

10.2

LINE MATCHING UNIT & LINE MATCHING DISTRIBUTION UNIT

SET

0.00

0.00

0.00

0.00

0.00

MTRS

500

500

1000

0.00

0.00

0.00

0.00

0.00

MTRS
NO

100
4

100
4

200
8

0.00
0.00

0.00
0.00

0.00
0.00

0.00
0.00

0.00
0.00

NOS

12

0.00

0.00

0.00

0.00

0.00

NOS

0.00

0.00

0.00

0.00

0.00

SET
Nos.

1
2

1
2

2
4

0.00
0.00

0.00
0.00

0.00
0.00

0.00
0.00

10

10.3
10.4
10.5
11

11.1

12
12.1
12.1.1
13
13.1
13.1.1
14

MTRS

12.5 mm OD armoured Co-axial Cable; Impedance: 75 ohms, Insulation Resistance: 100 Meg
Ohms Dielectric strength: 5 kV, Signal attenuation: 6 dB/KM (Max) at 500 kHz

4 PAIR NON ARMOURED TELEPHONE CABLES


2 WIRE TELEPHONE SET
SUB STATION LIGHTING (AS PER SPECIFICATION AND APPROVED DRAWINGS
)(Switch yard and other street area)
SUB-STATION SWITCH YARD LIGHTING,150 Watt Flood lighting,IT INCLUDES
SUPPLY OF FIXTURES & LAMPS (LED) of reputed make (Philips/CGL/Bajaj) with
switch gear,GI Conduit etc.(Lighting fixtures are to be fixed rigidly on the Column at a
suitable height so that the required lux can be maintained).
PROTECTION,CONTROL METERING, EVENT LOGGER,BUS BAR PROTN
PAN,COMM PAN, RELAY TOOL KITS AS PER TECH SPEC
132 KV SIDE
FEEDER CONTROL & RELAY PANEL(Duplex type)
AC & DC SYSTEM
AC SYSTEM
INDOOR RECEPTACLE BOARD
BEST QUALITY &APPROVED MAKE RUBBER MAT TO BE KEPT INFRONT OF ALL
PANELS,BOARDS
ETC.(1000mmX3000mmX12mm)
TOTAL
OF SUBSTATION-2A
(PART-I)

0.00
0.00

0.00

SUPPLY_ TRANSMISSION LINE EQUIPMENT/MATERIALS


S. No.

SUPPLY OF FOLLOWING EQUIPMENTS


(As per Technical Specification)

2
SUPPLY of Following type tested Lattice type Galvanized steel tangent / Angle tower
with stubs and cleats , different type of G.I HT Nuts & Bolts, washer, spring washer for
the towers ,hanger and all accessories, tower super structure complete including step
bolts. Supply of black bituminous paint for three coats up to a height of 500mm above
the cooping(legs & bracing members). All Supply should confirm to the Technical
Specification.

UNITS

TOTAL
Unit Ex-Works Price
QUANTITY for
IN INR
construction of
132KV SC
Transmission
line on DC tower
from
132/33kVKesing
a Grid S/s to
proposed
132/33kV
JunagarhGrid
S/s
(APPROX.LENG
TH 52.794 kms.)

PA TYPE (SUSPENSION ) TOWERS (Nominal unit weight 3.430 MT)

Nos.

147

+3 EXTENSION (Nominal unit weight 0.537 MT)


+6 EXTENSION (Nominal unit weight 1.349 MT)
PBTYPE (30 deg ANGLE ) TOWERS (Nominal unit weight 4.973 MT)
.+3 EXTENSION (Nominal unit weight 1.018 MT)
PC TYPE (60 deg ANGLE ) TOWERS (Nominal unit weight 6.214 MT)
.+3 EXTENSION (Nominal unit weight 1.119MT)
+6 EXTENSION (Nominal unit weight 2.342 MT)
UR TYPE TOWERS (Nominal unit weight 13.585 MT)
+6 EXTENSION (Nominal unit weight 4.249 MT)
TEMPLATES
PA (Nominal unit weight 0.665 MT)
PB (Nominal unit weight 0.602 MT)
PC (Nominal unit weight 0.904 MT)
UR (Nominal unit weight 1.509 MT)
WEIGHT OF THE STRUCTURES (including Tower stubs, Templates & Foundation
Nut and Bolts)
Weight of different type G.I Nuts and Bolts
Supply of the following tower accessories as per technical specification and as
directed by the engineer in charge.

Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.

19
10
26
3
12
1
1
4
4

EARTHING DEVICE
DANGER BOARD
NUMBER PLATE
PHASE PLATE
BIRD GUARD
ANTICLIMBING DEVICE
CIRCUIT PLATE
Supply of following POWER CONDUCTORS in the proposed 132 kV lines with
provision for sag and wastage as per the technical specification and as per the
instruction of the engineer in charge.
ACSR Panther (30/7/3.0 mm)
POWER CONDUCTOR ACESSORIES
For ACSR PANTHER
VIBRATION DAMPER
MID SPAN JOINT
Repair Sleeve
Supply of the GI earth wire of size 7/3.15 mm as per the technical
specification, with provision for Sag & Wastage and as per the direction of
Engineer in charge.
EARTH CONDUCTOR ACESSORIES
VIBRATION DAMPER
FLEXIBLE EARTH BOND
SUSPENSION CLAMP
TENSION CLAMP
MID SPAN JOINT
Repair Sleeve
Supply of the following Anti fog type disc insulators as per the technical
specification and as per the instruction of the Engineer in charge.
90 KN Insulator
120KN Insulator
Supply of the following hard ware fittings suitable for ACSR Panther
conductors as per the technical specification.
For ACSR PANTHER
Single suspension Hard wares fittings.(AGS type) suitable for 90 KN insulator.
Double suspension Hard wares fittings.(AGS type) suitable for 90 KN insulator.
Single tension Hard wares fittings suitable for 120 KN insulator.
Double tension Hard wares fittings suitable for 120 KN insulator.
D Shackle
Hanger

Total Ex-Works Price


IN INR

Unit F&I Charges


IN INR

Total F&I Charges


IN INR

Mode of Transaction
(Direct or Bought-out
item)

Unit Excise duty


IN INR

Unit VAT
IN INR

Unit CST
in INR

Any other tax


IN INR

Total Taxes and duties


IN INR

Unit FORD Price


IN INR

TOTAL FORD Price


IN INR

6=5X4

8=7X4

10

11

12

13

14=4X(10+11+12+13)

15=5+7+10+11+12+13

16=4X15

.
1.1
1.1.1
1.1.2
1.2
1.2.1
1.3
1.3.1
1.3.2
1.4
1.4.1
1.5
1.5.1
1.5.2
1.5.3
1.5.4
1.6
1.7
2.0
2.1
2.2
2.3
2.4
2.5
2.6
2.7
3.0
3.1
4.0
4.1
4.1.1
4.1.2
4.1.3
5.0
6.0
6.1
6.2
6.3
6.4
6.5
6.6
7.0
7.1
7.2
8.0
8.1
8.1.1
8.1.2
8.1.3
8.1.4
8.1.5
8.1.6

Note:
1
2
3
4
5

Nos.
Nos.
Nos.
Nos.

15
3
2
1

MT

947.47

0.00

0.00

0.00

0.00

0.00

MT

42.00

0.00

0.00

0.00

0.00

0.00

Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.

195
195
195
585
585
195
195

0.00
0.00
0.00
0.00
0.00
0.00
0.00

0.00
0.00
0.00
0.00
0.00
0.00
0.00

0.00
0.00
0.00
0.00
0.00
0.00
0.00

0.00
0.00
0.00
0.00
0.00
0.00
0.00

0.00
0.00
0.00
0.00
0.00
0.00
0.00

Kms.

160.76

0.00

0.00

0.00

0.00

0.00

Nos.
Nos.
Nos.

1170
160
160

0.00
0.00
0.00

0.00
0.00
0.00

0.00
0.00
0.00

0.00
0.00
0.00

0.00
0.00
0.00

Kms.

54.19

0.00

0.00

0.00

0.00

0.00

Nos.
Nos.
Nos.
Nos.
Nos.
Nos.

390
96
147
96
54
54

0.00
0.00
0.00
0.00
0.00
0.00

0.00
0.00
0.00
0.00
0.00
0.00

0.00
0.00
0.00
0.00
0.00
0.00

0.00
0.00
0.00
0.00
0.00
0.00

0.00
0.00
0.00
0.00
0.00
0.00

Nos.
Nos.

4170
6805

0.00
0.00

0.00
0.00

0.00
0.00

0.00
0.00

0.00
0.00

Nos.
Nos.
Nos.
Nos.
Nos.
Nos.

441
0
252
36
126
441

0.00
0.00
0.00
0.00
0.00
0.00

0.00
0.00
0.00
0.00
0.00
0.00

0.00
0.00
0.00
0.00
0.00
0.00

0.00
0.00
0.00
0.00
0.00
0.00

0.00
0.00
0.00
0.00
0.00
0.00

TOTAL (Part-II)-2A-LINE

0.00

TOTAL OF SUPPLY PRICE_SCHEDULE 2A

0.00

Before filling up rate/amount etc. in the schedules bidders are requested to read carefully the instruction given in Vol-I of Bidding Document.
Bidders are required to fill up amount in all column except shaded portion.
Bidders are requested to not leave any column blank. If any column is left blank it shall be considered that amount against those items are included in any other item and the total amount for that item shall be calculated as free of cost (Zero value).
In mode of transaction column please indicate Direct/Bought-Out. For Taxes & Duties on Direct/Bought-out items ref clause 6.0 of SCC (Vol-IA)
Bidder should quoted F&I including service tax, no service tax shall be paid/reimbursed on this account.

ODISHA POWER TRANSMISSION CORPORATION LIMITED

Name of the Work:-Construction of 132KV SC Line on DC tower from 132/33 KV, Kesinga Grid S/s to 132/33 KV, Junagarh Grid
S/s with 132KV feeder bay extension at both S/s ends.(App. Line Length: 52.794Kms.)
NOTICE INVITING TENDER-NIT NO. 67/2014-15

PACKAGE 67(III)/2014-15
BID DOCUMENT No.:Sr. G.M- CPC- TENDER- PACKAGE- 67(III)/2014-15

SCHEDULE-2C (Erection of Equipment/Materials Price Break-up against PACKAGE: 67(III)/2014-15

NAME OF THE BIDDER

ERECTION _ SUBSTATION EQUIPMENTS / MATERIALS


Sl No

ERECTION,TESTING & COMMISSIONING INCLUDING CIVIL WORKS OF FOLLOWING EQUIPMENTS ALONG WITH
CIVIL WORKS (As per Technical Specification)

1
PART A
1.0
1.1

2
ELECTRICAL WORKS
ERECTION OF SUPERSTRUCTURE :
Supply of labour,T&P and other necessary arrangements for erection of Columns,Beams,Equipments supporting structures &
Nuts and Bolts

2.0
2.1

ERECTION OF EQUIPMENTS
Supply of all labour ,T&P and Transportation from the site store,erections as per specification and testing
commissioning etc as per the instruction of the Engineer-in-charge.

UNITS

Quantity for: construction


Quantity for:
of 1 no. 132 kV feeder bay
Construction of
Extn. at 132/33kV Kesinga
1no.132Kv Fdr. Bay
SS
Extn. at 132/33KV SubStation at Junagarh SS

Total Quantity

Unit Erection Rate


IN INR

Total Erection Price


IN INR

8=6X7

MT

14

14

28

0.00

145 KV,(Different Ratio),31.5KA,4CORE SINGLE PHASE CURRENT TRANSFORMER


145 KV,1200A,31.5KA,ISOLATORS
S/I WITH OUT EARTH SWITCH
D/I WITH SINGLE EARTH SWITCH
145 KV,4400pF,3CORE,SINGLE PHASE CAPACITOR VOLTAGE TRANSFORMER
120 KV METAL OXIDE SURGE ARRESTOR, 10 KA, Class III

NOS

0.00

NOS
NOS
NOS

1
1
3

1
1
3

2
2
6

0.00
0.00
0.00

NOS

0.00

'2.1.5

132 KV Bus Post Insulators

NOS

0.00

'2.1.6

145KV,3150A,40KA,SF6,CIRCUIT BREAKER WITH SUPPORTING STRUCTURE

NOS

0.00

2.1.1
2.1.2
'2.1.2.1
'2.1.2.2
'2.1.3
'2.1.4

3.0
3.1

BUS-BAR STRINGING
Supply of labour,T&P and other necessary arrangements for stringing of bus bar conductors,hoisting of single or double
insulator strings,Single or Double Hard-wares Fittings, Clamp & connectors, as per requirements, Jumpers, connections to
Equipments,testing,commissioning etc. as per the instruction of Engineer-in charge.

3.1.1
3.1.2
4.0

Single conductor
Twin Conductor
SUB-STATION EARTH-MAT
Substation earth-mat Design, engineering, supply inclusive of corrosion protection measures if any,laying of earth-mat
conductors of Hot dip galvanized flats of size 75X10mm to the approval of Project Manager, excavation, welding/jointing
,application of two coats of bituminous Paint,wrapping of HT Tape etc of ground conductors along with risers (of size 50X6
mm GI flats) etc back filling and good compaction,grounding driven rods(40 mm MS solid rod),perforated GI pipes for treated
earth pits(with details of treatment as per IS). The spacing between the earth conductor not more than 5 mtrs(both way) and
to be buried at depth of 700mm from the finished ground level. For provision of treated earth-pit and untreated earth pit, refer
the specification for designing. Provision of water taps inside the switch yard areas and peripheral treated and un-treated
earth pit are required to be provided for watering the treated earth pits. The no. of treated and un treated earth pits are to be
done as per the practice and as indicated in the drawing for different equipments. This is as per approved drawing and
specification.

Mtr.
Mtr.

350
150

350
150

700
300

0.00
0.00

MTRS
MTRS
NOS
NOS

700
450
25
25

700
450
25
25

1400
900
50
50

0.00
0.00
0.00
0.00

Mtrs
Mtrs
Mtrs
Mtrs

80
70
50
2

80
70
50
2

160
140
100
4

0.00
0.00
0.00
0.00

5.1

75x10 MM GI FLAT
50x6 MM GI FLAT
40 MM MS ROD FOR NON-TREATED EARTH PIT ELECTORDE
50MM GI PIPE FOR TREATED EARTH PIT ELECTRORDE WITH CHAMBER AND COVER
Fixing G.I Cable Trays including fixing of Link- plate & with supply of all labour and T & P etc. suitable for different sections i.e.
Section:1-1,2-2,3-3 & 4-4 along with its accessories as per TS.
Section 1-1
Section 2- 2
Section 3-3
Section 4-4
Laying of Power and Control Cable including fixing of cable with terminal connections both at equipments and control panels
with supply of and fixing of lugs,Ferrules,clamps,connectors,glands,fixing of cable trays, including supply of N&B,Link
plates,Cable Markers,PVC pipes Bends,Plaster of Paris, M-Seal compounds etc for sealing purpose and all necessary
arrangements,laying of Earthing Flats,earthing ,laying of Cable trench slabs and chequered plate etc for the cable
trench,Cable scheduled and cable diagram to be prepared by the contractor
POWER CABLES,1.1KV,XLPE,ARMOURED, ALUMINIUM CONDUCTOR (As per Specification)

5.1.5

PVC 3.5 CX35 mm2

MTRS

250

250

500

0.00

5.1.7
5.1.8
5.2
5.2.1
5.2.2
5.2.3
5.2.4
5.2.5
5.2.6

MTRS
MTRS

250
200

250
200

500
400

0.00
0.00

MTRS
MTRS
MTRS
MTRS
MTRS
MTRS

500
2500
500
500
1000
1000

500
2500
500
500
1000
1000

1000
5000
1000
1000
2000
2000

0.00
0.00
0.00
0.00
0.00
0.00

NOS

0.00

SET

0.00

MTRS

500

500

1000

0.00

'6.4

PVC 4 CX 6 mm2
PVC 2CX 6 mm2
CONTROL CABLES, 1.1 KV, PVC, STRANDED COPPER(As per specification)
2 CX 2.5 mm2
4 CX 2.5 mm2
5 CX 2.5 mm2
7CX 2.5 mm2
10 CX 2.5 mm2
12 CX 2.5 mm2
ACCESSORIES FOR PLCC SYSTEM AS PER TECHNICAL SPECIFICATION)
132 kV Line Trap for Pedestal mounting with complete accessories :800A, 0.5 mH, (90-500kHZ),Isc=31.5kA compatible to
IEC 353 specifications
LINE MATCHING UNIT HAVING BUILT-IN PROTECTIVE DEVICES LIKE DRAINAGE COIL, SURGE ARRESTOR AND
EARTH SWITCH. TUNABLE BAND PASS COUPLING FILTER: 90-500KHZ. HF POWER RATING: 650 W & LINE
MATCHING DISTRIBUTION UNIT
12.5 mm OD armoured Co-axial Cable; Impedance: 75 ohms, Insulation Resistance: 100 Meg Ohms Dielectric strength: 5
kV, Signal attenuation: 6 dB/KM (Max) at 500 kHz
4 PAIR NON ARMOURED TELEPHONE CABLES

MTRS

100

100

200

0.00

'6.5

2 WIRE TELEPHONE SET

NO

0.00

7
7.1
7.2
8

SUB STATION SWITCYARD BMK,AC CONSOLE & OTHER MARSHALLING BOXES


BAY MARSHALLING KIOSK
CT & CVT Out Door Console Boxes
SUB STATION LIGHTING(AS PER SPECIFICATION AND APPROVED DRAWINGS)
Switch yard lighting: Design, engineering, procurement of labour, material including all associated works for construction
of switch yard lightings as per technical specification and approved drawings. The fixture shall be of reputed make
(Philips/CGL/Bajaj) and fixtures shall be 150Watt Flood light lamps(LED) and proper cabling from the lighting outdoor
distribution boards to the junction boxes and from junction boxes to the fixtures. The lighting fixtures are to be installed on the
switch yard structures. The quantity of such fixtures are to be designed and to be ascertained.

NOS
NOS

1
2

1
2

2
4

0.00
0.00
0.00

NOS

12

0.00

NOS

0.00

SET

0.00

SET

0.00

ERECTION OF PLCC EQUIPMENT SUPPLIED BY OWNER INCLUDING DISMANTLING FROM EXISTING


SUBSTATION ( AS PER THE DETAILS SLD GIVEN IN TS) AND TRANSPORTATION AS REQUIRED

SET

0.00

BEST QUALITY & APPROVED MAKE RUBBER MAT TO BE KEPT INFRONT OF ALL PANELS,BOARDS ETC.(Size
1000mm x 3000mm x 12mm)

NOS

4.1

4.1.1
4.1.2
4.1.3
4.1.4
4.1.5
'4.1.5.1
'4.1.5.2
'4.1.5.3
'4.1.5.4
5.0

6.0
'6.1
'6.2
'6.3

8.1

9
9.1
9.1.1
10
10.1
10.1.1

11.0

12

13.0

PROTECTION,CONTROL METERING,EVENT LOGGER,BUS BAR PROTN PAN,COMM PAN,RELAY TOOL KITS AS


PER TECH SPEC AND BOQ FOR PCM (ANNEXURE-II-E-BOQ-PCM)

132 KV SIDE
FEEDER CONTROL & RELAY PANEL(Duplex type)
AC & DC SYSTEM
AC SYSTEM
INDOOR RECEPTACLE BOARD
COLOUR CODING, BAY MARKING Etc:Design, engineering, procurement of labour, material including all associated
works for the followings. This should be as per direction of site In charge. a)Color coding (red,Yellow & Blue) for
equipments,Bus gantry &column of entire switch yard. Good quality weather proof sticker may be used for identification.
b)Each bay should be identified with the help of bay marker sign board, suitably grouted. MS sign board with stand to be
installed. Proper painting and lettering to be done of the entire switch yard area.

PART B
14
14.1

14.2

0.00

0.00

TOTAL OF ELECTRICAL WORKS (A)


CIVIL WORKS
CONTOUR SURVEY,AND LEVELING, BACK FILLING
Contour survey and furnishing contour map including supply of all materials, Labour and T&P
Soil investigation : Supply of labour,T&Pand other necessary arrangements for Soil investigation/testing of the
Switchyard,control Room, Quarters area etc.as per the site requirement,Technical specification & instruction of Engineer-inCharge.

SQ.MTRS.

600

600

1200

0.00

PER POINT

0.00

CUM

300

300

600

0.00

Cutting, Filling and Leveling of Sub-station area including supply of labour and T&P
15

15.1

15.1.1
15.1.2
15.2
15.2.1
16
16.1

LEVELLING OF S/S AREA:Providing, neatly dressing up and levelling of substation area including switchyard area to a
required level as decided by the Engineer in Charge, the work includes removal, clearing of the entire area from vegetation,
trees, bushes, uprooting of plants and disposal of surplus earth and unusable material from the site by means of any
mechanical transport, if required as per direction of the Project In charge, with all labours, tools, tackles and plants complete
as per approved drawing and specification. This also includes excavation in all type of soils or rocks, back filling and disposal
of excess earth or rocks to make the area to a level for construction as per scope and as per approved drawing and
specification.
CUTTING of substation area
Soft/loose soil
FILLING of substation area with borrowed earth with supply of all labour,T & P.
Beyond 100mtr lead
Anti-Weed Treatment
Supply of labour,T&P,Chemicals and other necessary arrangements for anti-weed treat of the switch-yard areas,controlroom
etc. as per the instruction of Engineer-in-Charge.

CUM

100

100

200

0.00

Sq.Mtrs

450

450

900

0.00

Excavation for OPEN CAST foundation and back filling of columns,Equipments foundations,including supply of
all labours,T&P,and materials and as per the direction of the Engineer-in-Charge.
17

'17.1
'17.2

Soft Soil/Loose Soil.


Hard Soil.

CUM
CUM

200
150

200
130

400
280

0.00
0.00

'17.3

Soft/Disintegrated Rock( not Requiring Blasting)

CUM

100

100

200

0.00

'17.4
18

Hard Rock (Requiring Blasting/Using Rock Breaker Machinery)


OPEN CAST/SHALLOW FOUNDATION CONCRETE WORKS

CUM

30

50

80

0.00

18.1

Foundations : Design, engineering, supply of all labour, material and construction(open cast foundation) of PCC, RCC
footings of any depth, pedestal including the cost of soil investigation, concreting, cement, reinforcement steel FE-500,
shuttering, grouting, underpinning and back filling of foundations etc complete for the switchyard gantry/ portal /column
structures and equipment support as per the technical specification and approved drawings & disposal of excess earth as
per the direction of Engineer In charge.
PCC(1:3:6)
(RCC) MIX 1:1.5:3 (of grade M20)
Design, engineering, and construction of RCC(1:1.5:3) cable trenches and all associated works for cable trench crossings
to the required depths, precast RCC covers(1:1.5:3), water stops, brickwork with plastering wherever required including the
supply of labour,material, cement, reinforcement steel, formwork, steel angles(G.I), flats(G.I) and providing PCC(1:3:6) below
cable trenches as per technical specifications and approved drawings and as per direction of the Project Manager. This also
includes excavation in all types of soil or rocks,backfilling,and disposal of excess earth as per the direction of Engineer In
charge. The cable tray support frame shall be pre fabricated GI angle as per requirement and to be welded with the plate fixed
on the trench wall for better rigidity. The plate (6mm) fixed on the wall are also to be welded with the MS rods provided for the
trench wall before concreting.
*CABLE TRENCHES INSIDE THE CONTROL ROOM SHALL BE COVERED WITH M.S CHEQUERED PLATE
INCLUDING STANDARD SUPORT.

CUM
CUM

16
85

16
85

32
170

0.00
0.00

Mtrs
Mtrs
Mtrs
Mtrs

25
20
20
20

25
20
20
20

50
40
40
40

0.00
0.00
0.00
0.00

Nos
Nos

1
1

1
1

2
2

0.00
0.00

CUM

30

30

60

0.00

CUM

35

35

70

0.00

7 mtrs concrete road with shoulder at both the side as per technical specification indicated in the civil section(from the
switch yard main gate to all internal roads of the switch yard).Shall have drain on both side of the road.

MTRS

20

20

40

0.00

23

Switchyard fencing: Providing and fixing of G.I chain link(2.5mm dia) fencing( the posts and links shall be of HD
Galvanised ) in switch yard and other areas of the substation with a total fence height complete as per specification and
approved drawings, and as required under the safety regulation of local, state and central government bodies and as per
instruction of the Engineer-in-Charge.(The PCC work for grouting the post shall be 1:2:4 and a continuous RR masonary
work with ratio 1:5 and cement pointing of the joints, for the fencing upto a height of 350mm from the finished ground level)
.This also includes excavation in all types of soil or rocks,backfilling,and disposal of excess earth as per the direction of
Engineer In charge. The earthing of the fencing as per specification.

MTRS

55

55

110

0.00

24

Any other civil work to be included in the schedule by the Bidder if required essential for successful completion of project,
including supply of labour, material, cement reinforcement steel, form work etc. Bidder shall also quote the unit rate for the
following items of works.(Rate shall be inclusive of supply of labour, material, cement, reinforcement steel, form work etc. )

18.1.1
18.1.2

19

19.1
19.1.1
19.1.2
19.1.3
19.1.4
19.2
19.2.1
19.2.2

20

21

Cable trench with covers


Section 1-1
Section 2- 2
Section 3-3
Section 4-4
Cable trench crossing:Design,engineering,construction including supply of labour, materials, cement, reinforcement steel,
form box etc,and all associated works for construction of trench crossing as per technical specification and approved
drawing.
Section 2- 2
Section 3-3
PCC before site surfacing :Providing and supplying all labour, material, equipments etc. required for proper levelling of
earth after erection of structures and equipments and proper compaction by using roller of adequate capacity(minimum 3 Ton
capacity) with water sprinkling of switch yard area .After proper levelling of the switch yard area (after anti-weed treatment),
spreading of plain cement concert with mixing ratio 1:4:8 (M10) and maintaining proper sloping for easy discharge of storm
water having concrete thickness of 75 mm. including rolling , dressing, compacting,the area . As per technical specification
and approved drawing, and as per the instruction of the Engg-in-Charge.This also includes excavation in all types of soil or
rocks,backfilling,and disposal of excess earth as per the direction of Engineer In charge and approved drawing.
METAL SPREADING IN THE SWITCH-YARD

21.1

Providing supplying and laying two layers of machine crushed metals (gravel) fill, the first layer after compaction shall make
minimum 50 mm thickness coarse/ layer of 20 mm nominal size consolidated/ compacted and (by using roller as specified in
the specification).A final layer of 50 mm thickness of machine crushed 20 mm nominal size of metals(gravel) above the first
layer of 50 mm thickness and as per the technical specification and instruction of Engineer in charge above the
PCC(1:4:8).The total compacted thickness of the metals(20 mm Nominal) 100mm above the PCC.

22

Roads: Design, construction of roads and walkways/ shoulders within sub-station as per specification, layout and approved
drawings complete. This also includes excavation in all types of soil or rocks,backfilling,and disposal of excess earth as per
the direction of Engineer In charge. Provision of drains on both the side of the roads for easy discharge of rain water.

22.1

24.1
24.2
24.3
24.4
24.5

Excavation. This also includes excavation in all types of soil or rocks,backfilling,and disposal of excess earth as per the
direction of Engineer In charge.

CUM

0.00

PCC 1: 4 : 8
PCC 1: 3 : 6
RCC M 15

CUM
CUM

0
0

0
0

0
0

0.00
0.00

CUM

0.00

RCC M 20

CUM

0.00
0.00

Brick masonry work in cement sand mortar 1: 6 with bricks of class designation 150KG/SQ.MTR.

CUM

24.7

12 mm thick plaster in cement sand mortar ( 1: 6 ).

SQ. MTRS.

24.8

Supply,Cutting,bending and fixing of reinforcement.

MT

24.6

0.00
0.00

0.00
0.00

TOTAL OF CIVIL WORKS (B)


GRAND TOTAL S/S BAY EXTN ( ELECTRICAL WORKS + CIVIL WORKS) (A+B)
ERECTION_TRANSMISSION LINE EQUIPMENTS / MATERIALS
S. No.

TOTAL QUANTITY
for construction of
132KV SC
Transmission line
on DC tower from
132/33kVKesinga
Grid S/s to
proposed 132/33kV
4

Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.
Nos.

147
19
10
26
3
12
1
1
4
4

Nos.
Nos.
Nos.
Nos.

15
3
2
1
947.47
42.00

0.00
0.00

DESCRIPTION OF ITEMS
ERECTION,TESTING & COMMISSIONING OF FOLLOWING EQUIPMENTS ALONG WITH CIVIL WORKS (As per Technical
Specification)
UNITS

1
PART A
1.0
1.1
1.1.1
1.1.2
1.2
1.2.1
1.3
1.3.1
1.3.2
1.4
1.4.1
1.5
1.5.1
1.5.2
1.5.3
1.5.4
1.4.4
1.4.5

2.0

2.1
3.0
3.1

4.0

2
ELECTRICAL WORKS
ERECTION,TESTING & COMMISSIONING of tested Lattice type Galvanized steel tangent / Angle tower super structures
without
stubs
and cleats including
different
type of unit
G.I HT
Nuts3.430
& Bolts,
PA TYPE
(SUSPENSION
) TOWERS
(Nominal
weight
MT)washer, spring washer for the above type towers ,hanger
+3 EXTENSION (Nominal unit weight 0.537 MT)
+6 EXTENSION (Nominal unit weight 1.349 MT)
PBTYPE (30 deg ANGLE ) TOWERS (Nominal unit weight 4.973 MT)
.+3 EXTENSION (Nominal unit weight 1.018 MT)
PC TYPE (60 deg ANGLE ) TOWERS (Nominal unit weight 6.214 MT)
.+3 EXTENSION (Nominal unit weight 1.119MT)
+6 EXTENSION (Nominal unit weight 2.342 MT)
UR TYPE TOWERS (Nominal unit weight 13.585 MT)
+6 EXTENSION (Nominal unit weight 4.249 MT)
TEMPLATES
PA (Nominal unit weight 0.665 MT)
PB (Nominal unit weight 0.602 MT)
PC (Nominal unit weight 0.904 MT)
UR (Nominal unit weight 1.509 MT)

5.0

5.1

5.2
5.3
5.4
5.5
6.0
6.1
'6.1.1
'6.1.2
'6.1.3
'6.1.4
'6.1.5
'6.1.6
7.0
7.1
7.2
7.3
7.4
8.0
8.1

8.1.1

8.2

8.2.1

8.2.1.1
8.3
8.3.1
8.4

8.4.1

8.4.1.1
8.5
8.5.1

Total Erection Price


IN INR

6=4x5

WEIGHT OF THE STRUCTURES (including Tower stubs, & Foundation Nut and Bolts)
Weight of different type G.I Nuts and Bolts
Hoisting and fixing of insulators with required accessories(power conductor accessories,Earth conductor
accessories,Anti fog type insulators & hard ware fittings,tower accessories etc), paying out of conductor
,jointing, stringing, sagging & Jumpering etc. of power conductor with G.I. Earth wire in the proposed lines and
with earth wire with all required accessories including scaffolding for 33 KV,11 KV, LT , P&T lines, roads and
using own required T&P and compression jointing machines etc. with provision for Sag & Wastage and as per
the direction of Engineer in charge.

MT
MT

SINGLE CIRCUIT(ACSR/AAAC,THREE POWER CONDCTOR & 1 EARTH WIRE)


WELDING OF N & B
Supply of all materials for continuous welding of bolts & nuts (around the bolts) up to top of tower without cross arm, including
welding rods, welding generator machine (diesel engine operator.), application of required zinc rich paints around the welding portion
after welding (two coats),fuel,lubricants,T&P and labours and other arrangements etc.
PTCC approval, railway crossing has to be obtained by submitting the required documents to the concerned department through
OPTCL. Way-Leave blockade charges and any other charges are to be borne by the bidders. The documents for PTCC clearance &
Railway clearance including required drawings etc has to be submitted by the contractor within 5 months of award of contract. Beyond
the above period L.D as applicable & the amount shall be deducted as specified in the specification.

RKM

52.794

0.00

Nos.

125816

0.00

SET

CIVIL WORKS
SURVEY OF LINE & PREPARATION LAND SCHEDULE: Supply of required T&Ps, Technical personnels, labours for
conducting
Preliminary survey, Detail survey and resurvey (required for avoiding ROW problem) including but not limited to taking of levels,
profile plotting, tower spotting ,marking of towers locations at site including showing P&T line, power line, Railway line, river
crossing, roads and submission of route map and survey report etc. The P&T lines and railway lines for a minimum distance of 8 kms
on either side of alignment shall be clearly indicated.
Preparation of land schedule on revenue (if required)maps indicating alignment therein duly authenticated by Revenue Inspector &
Tahasildar, enumeration of trees with the help of Forest officer and other prominent features required for alignment of the proposed
132 KV line. Final route to be plotted on 1:50000 topo sheet for approval.
Check survey including supply of all labour, T&P as per instruction of Engineer in Charge and as per the approved profile.
Soil Testing in complete shape along with submission of report etc. up to the depth of 15mtrs.
Soil Testing in complete shape along with submission of report etc. upto the depth of 45 mtrs for River bed pile.
EXCAVATION WORKS FOR OPEN CAST/SHALLOW TYPE FOUNDATIONS/CAPPING WORK FOR PILE
FOUNDATION
Excavation in all type soil and rocks and back filling (back filling shall be done in layers of 500mm sprinkling of water and
compaction thereafter and disposed of excess quantity of excavated soil at suitable place after back filling), including all T&P,
labour as required.
Soft/Loose soil
Wet soil
Partial Submerged soil
Fully submerged soil

Soft/Disintegrated rock(Not requiring Blasting)


Hard Rock(Requiring Blasting/Using breaker machinery)
Fixing of of Templates & setting of stubs
PA Type
PB Type
PC Type
UR Type
FOUNDATION MATERIALS: Supply of all materials like cement, steel, all coarse aggregates, fine aggregates and making
foundations of the required above mentioned type towers as per the direction laid down in the technical specification and the
direction of the site- in charge
PCC(Lean Concrete) in the ratio 1:3:6(Grade M-10)
(i) FOR OPENCAST FOUNDATION:Providing & laying of RCC work of ratio 1:1.5:3 (Grade M-20) with approved quality
stone chips of nominal size 12mm to 20mm in tower foundation and cooping inclusive of cost of mixing, supply of form boxes
Chimney & fixing, curing, testing of sample cement concrete cubes & cost of all materials like cement,reinforcement steel FE-500 etc.
as per IS.456
(ii) The cooping height shall be 350mm above the ground level. The surrounding area shall be clear from materials and damage of
land if any shall be repaired before measurement and as per requirement, including labours and T&P as per specification in the
concrete ratio 1:1.5:3 (Grade M-20.)
PILE FOUNDATION (UNDER-REAMED )
Supply of all materials like cement, steel, all coarse aggregates, fine aggregates and making Under-reamed pile foundations (after pile
boring as per required depth, basing on design by means of manual Auger or motor driven machinery etc. ) of the required above
mentioned type towers and as per requirement, including supply of all equipments with labours, proper curing of the foundations
and T&P as per specification in the concrete ratio 1:1.5:3 (Grade M-20.) including supply of Bentonite required for stabilization bore
of required diameter bore holes applicable for under ream piles up-to the depth of 20 Mtrs.
375MM DIA
500MM DIA
CAPPING,PEDESTAL & TIE-BEAM CONCRETE WORKS OF UNDER-REAMED PILE
Pile riser (if required),capping, tie beams etc, required for stub setting including supply of rods-FE-500, cement, different gradient for
concrete ratio 1:1.5:3 (Grade M-20.) including curing minimum for 15 days continuous with excavation in all type of soils and back
filling etc.
PILE FOUNDATION (RIVER BED PILE BORING BY DMC METHOD )
Supply of all materials like cement, steel, all coarse aggregates, fine aggregates and applying DMC Method pile foundations (after
pile boring as per required depth, basing on design by means of machinery and high power pumps etc. used for DMC method piling)
of the required above mentioned type towers and as per requirement, including supply of all equipments shoring & shuttering
materials, dewatering with labours, proper curing of the foundations and T&P as per specification in the concrete ratio 1:1.5:3 (Grade
M-20.) including supply of Bentonite required for stabilization bore of required diameter bore holes applicable for piles beyond 20
Mtrs.
1000 MM DIA
PILE RISER,CAPPING,PEDESTAL & TIE-BEAM CONCRETE WORKS OF RIVER-BED PILE.
PCC(Lean Concrete) in the ratio 1:3:6(Grade M-10)

0.00

0.00

Total ELECTRICAL Works (Part-A)-LINE-2C


PART B

Unit Erection Rate


IN INR

KM.

53

0.00

KM.

53

0.00

KM.
Per Loc.
Per Loc.

53
42
0

0.00
0.00
0.00

CUM
CUM
CUM
CUM
CUM
CUM

4800
7250
20
15.58
782.87
365.55

0.00
0.00
0.00
0.00
0.00
0.00

Sets
Sets
Sets
Sets

147
26
12
4

0.00
0.00
0.00
0.00

CUM

254

0.00

CUM

2022

0.00

MTR
MTR

0
0

0.00
0.00

CUM

0.00

MTR

0.00

CUM

0.00

8.5.2
8.6
8.6.1
8.7
8.7.1
8.8
8.9
9.0
'9.1
'9.2
'9.3
'9.4
'9.5
10.0

Pile riser (if required),capping, tie beams etc, required for stub setting including supply of rods-FE-500 , cement, different gradient for
concrete ratio 1:1.5:3 (Grade M-20.) including curing minimum for 15 days continuous with excavation in all type of soils and back
filling etc.
DE-WATERING(FOR OPEN CAST LOCATION)
(ii) With Supply of all T&P, Fuel, Lubricant & electricity on HP Hour basis.
Supply of borrowed earth/morrum for back filling for foundation/revertment works
(iii beyond 100 mtr lead
SHORING & SHUTTERING-Required in wet/submerged or special locations of open cast/shallow type foundations with
supply of all materials,T&P and Labour.
Head-Loading of all types of foundation-materials,towers,structures, conductors,Insulators,Hard-wares & Emergency Restoration
System towers required for special inaccessible Locations beyond 400 mtrs from the nearest approach road as per the
recommendation of site Engineer-In- Charge and approval of GM of Concerned circle.
REVERTMENT / STONE PITCHING FOR PROTECTION OF TOWER BASE.
Excavation in all type of soil including rock
& back filling including supply of sand with back filling.
Lean Concrete in the ratio1:3:6(Grade M-10) including supply of sand chips etc.
PCC in the ratio 1:2:4(Grade M-15) as above.
RR Massonary work in the ratio 1:5.
Plastering and punning etc.
Erection of earthing device including supply of materilas as per Technical Spec

CUM

0.00

HP Hour

0.00

CUM

0.00

SQ.MTR.

0.00

Per MT/Per Mtr

0.00

CUM

9040

0.00

CUM
CUM
CUM
SQ.MTR.
Nos.

218
56
3132
320
195

0.00
0.00
0.00
0.00
0.00

Total CIVIL Works (Part-B)-LINE-2C


TOTAL OF LINE-2C (PART-II)(Part A + Part B)

0.00
0.00

ERECTION PRICE_ TOTAL OF SCHEDULE 2C

0.00

NOTE:1 Before filling up rate/amount etc. in the schedules bidders are requested to read carefully the instruction given in Vol-I of Bidding Document.
2 Bidders are required to fill up amount in all column except shaded portion.
3 Bidders are requested not to leave any column blank. If any column is left blank it shall be considered that amount against those items are included in any other item and the total amount for that
4 Bidder has to quote rates excluding service tax (if any), service tax shall be paid/reimbursed as per conditions of Bid Document.

ODISHA POWER TRANSMISSION CORPORATION LIMITED


Name of the Work:-Construction of 132KV SC Line on DC tower from 132/33 KV,
Kesinga Grid S/s to 132/33 KV, Junagarh Grid S/s with 132KV feeder bay extension at
both S/s ends.(App. Line Length: 52.794Kms.)

PACKAGE 67(III)/2014-15

NOTICE INVITING TENDER-NIT NO. 67/2014-15


BID DOCUMENT No.:Sr. G.M- CPC- TENDER- PACKAGE- 67(III)/2014-15

SCHEDULE 1_ ABSTRACT OF PRICE SCHEDULES (SUBSTATION &


LINE)

NAME OF THE BIDDER


SL NO.
1
1.0
1.1
1.2
1.3
1.4
1.5
1.6
1.1 :1.6
2.0
2.1
2.2
2.3
2.4
2.5
2.6
2.1 :2.6
3.0
3.1
3.2
3.3
3.4
3.5
3.6
3.1 :3.6
4.0
5.0
5.1
5.2
5.1 :5.2
6.0
6.1
6.2
6.1 :6.2
7.0
8.0

DESCRIPTION
2
Substation_Supply of Equipments and materials
TOTAL of Ex-Works / Basic Price
TOTAL Excise Duty
TOTAL VAT
TOTAL CST
TOTAL Any other tax
TOTAL F&I CHARGES
Total of Substation_Supply
Transmission Line_Supply of Equipments and materials
TOTAL of Ex-Works / Basic Price
TOTAL Excise Duty
TOTAL VAT
TOTAL CST
TOTAL Any other tax
TOTAL F&I CHARGES
Total of Transmission Line_Supply
Mandatory spares_Supply
TOTAL of Ex-Works / Basic Price
TOTAL Excise Duty
TOTAL VAT
TOTAL CST
TOTAL Any other tax
TOTAL F&I CHARGES
Total of Mandatory spares_Supply
Total of Schedule 2A _ Supply contract price
Substation_ (Electrical work charges, Civil work charges)
Electrical works
Civil works
Total of Substation_Electrical work charges & Civil works charges
Transmission Line_(Electrical work charges, Civil work charges)
Electrical works
Civil works
Total of Transmission Line_Electrical work charges & Civil works
charges
Total of Schedule 2C _ Erection contract price
Total Bid Price (Supply + Erection)

PRICE IN INR

0.00

0.00

0.00
0.00

0.00

0.00
0.00
0.00

ODISHA POWER TRANSMISSION CORPORATION LIMITED


Name of the Work:-Construction of 132KV SC Line on DC tower from 132/33 KV, Kesinga Grid S/s to 132/33 KV, Junagarh Grid S/s with 132KV feeder
bay extension at both S/s ends.(App. Line Length: 52.794Kms.)
NOTICE INVITING TENDER-NIT NO. 67/2014-15
BID DOCUMENT No.:Sr. G.M- CPC- TENDER- PACKAGE- 67(III)/2014-15
SCHDULE 1 (PART-II) (D1, D2,E,F,G) - DETAILS OF TAXES AND DUTIES
NAME OF THE BIDDER
Description of Applicable Tax/Levy
Item /Component Sl. No. of Bid price on which
Applicable
Details of Taxes and levies on the direct transactions
between Bidder and ODISHA POWER
TRANSMISSION CORPORATION LTD.
applicable on the date of bid opening, not included
in the Bid Price above but as may be payable by
ODISHA POWER TRANSMISSION
CORPORATION LTD

Sl No
D1

(i)

Excise Duty [as per Schedule-2A]

(ii)

CST [as per Schedule-2A]

(III)

VAT/Sales Tax [as per Schedule-2A]

(iv)

Any other Levies: [as per Schedule-2A] except Entry


Tax** (please specify): Central :-

Tax @ __% Total Amount of


Taxes /Duty/ Levies

(a)

(b)

TOTAL OF TAXES AND DUTIES [Sum (i) to (iv)


D2

Service Tax***

E. Applicable Entry tax payable if any additionally in


respect of bought-out finished items which shall be
dispatched directly from our sub-vendors works to
Employers site (sale-in-transit).

F. Total Bid Price: (including Taxes & Duties and


other levies, but excluding entry tax and service tax,
if the contract is awarded to us)

G. The total bid price as summarised herein is


derived from Schedule 2A,2B, 2C and 3, However,
in the event of a difference in prices between
schedule-2A ,2B,2C & 3 and Schedule-1, the total
price, derived from the quoted unit price in Schedule
2A ,2B,2C and 3 after arithmetical corrections if any,
shall prevail and the quoted total bid price

0.00

* List of the items and their values considered under this component of bid price for taxes and levies to be enclosed by separately as annexure to this
** Entry Tax for all direct items shall not be included in the bid price, as the same shall be reimbursed at actual on the production of documentary evidence
*** Service Tax on Erection price shall not be included in the bid price, as the same shall be reimbursed at actual on the production of documentary evidence.
NOTE:- Lumpsum prices quoted by the Bidder shall include cost of total scope of work and any other supplies/work(s) not specifically mentioned in the
i) Excise Duty/VAT/Sales Tax/Service Tax/ any other taxes (except Octroi & Entry Tax) shall be inclusive in the bid price and shall not be paid/reimbursed
ii) Entry Tax for bought out items shall not be included in the bid price, as the same shall be reimbursed at actual on the production of documentary
evidence.