You are on page 1of 121

Development of Novel Carbon Sorbents for

CO2 Capture
Final Technical Report
Start Date:

October 1, 2008

End Date:

November 30, 2013

Principal Author:

Dr. Gopala N. Krishnan, Associate Director


Materials Research Laboratory

Contributors:

Dr. Marc Hornbostel, Dr. Jianer Bao, Dr. Jordi Perez,


Mr. Anoop Nagar, and Dr. Angel Sanjurjo

Date Report Issued:

March 2014

DOE Award Number:

Cooperative Agreement No. DE-NT0005578

Submitting Organization: SRI International


333 Ravenswood Avenue
Menlo Park, CA 94025
Project Partners:

ATMI, Inc.
7 Commerce Drive, Danbury, CT 06810
The University of Toledo
Department of Chemical and Environmental Engineering,
3048 Nitschke Hall, 1610 N Westwood Ave, Toledo, OH 43607

Prepared for:

U.S. Department of Energy


National Energy Technology Center
3600 Collins Ferry Road
Morgantown, WV 26505
Attention: Mr. Andrew OPalko

P18775 Final Report

P18775 Final Report

P18775 Final Report

P18775 Final Report

P18775 Final Report

P18775 Final Report

P18775 Final Report

P18775 Final Report

P18775 Final Report

P18775 Final Report

P18775 Final Report

P18775 Final Report

P18775 Final Report

P18775 Final Report

P18775 Final Report

P18775 Final Report

P18775 Final Report

P18775 Final Report

P18775 Final Report

P18775 Final Report

P18775 Final Report

120.0
Temperature: 5 C

20 wt% CO2

CO2 Adsorbed (cm3/g)

100.0
Desorption

80.0

Adsorption

60.0
40.0
20.0
0.0
0.00

0.20

0.40

0.60

0.80

CO2 Partial Pressure (atm)

1.00

1.20

P18775 Final Report

120.0
Temperature: 5 C

CO2 Adsorbed (cm3/g)

100.0
10C
15C

80.0

20C
30C

60.0

40.0

20.0

0.0
0.0

0.2

0.4
0.6
0.8
CO2 Partial Pressure (atm)

1.0

1.2

P18775 Final Report

Log (Volume of CO2 Adsorbed/g)

2.5

2.0

1.5

1.0
y = -0.1298x + 2.2878
R2 = 0.9996

0.5

0.0
0

8
2

Log (Po/P)

10

12

14

P18775 Final Report

114

Temperature

100

110
80
108
60
106
Weight

40

104
102

20

100

0
40

140

240

340

440

Elapsed Time (Minutes)

540

Temperature (C)

Relative Weight (%)

112

120

P18775 Final Report

140

Temperature
100% CO2

110

120
100

75% CO2

108

80
50% CO2

106

60
25% CO2

104

40

102

20

100
250

300

350

400

450

500

550

0
600

Elapsed Time (Minutes)

12

Wt% CO2 on the Sorbent

Relative Weight (%)

112

%CO2 in CO2-Ar Gas Mixture


100

10
75

8
50

6
25

4
15

2
0
0

20

40

60
80
Temperature (C)

100

120

Temperature (C)

114

P18775 Final Report

7.0
6.5

Ln Equilibrium CO2 Pressure

6.0

CO2 adsorbed:
65 cm3/g
60
55
50
45
40
35

5.5
5.0
4.5

30
25

4.0

20

3.5
15

3.0
10

2.5
3.2E-03

3.3E-03

3.4E-03

3.5E-03

Inverse Temperature (1/K)

3.6E-03

3.7E-03

P18775 Final Report

30

Heat of Adsorption (kJ/mol)

29
28
27
26
Latent Heat of Vaporization of CO2

25
24
23
22
21
20
0

10

20

30

40

50
3

Quantity of CO2 Adsorbed (cm /g)

60

70

P18775 Final Report

7.0

Ln CO2 Partial Pressure

6.5
40

6.0

30
25
20
15

5.5
5.0
4.5

10

4.0
CO2 adsorbed: 5 cm3/g

3.5
3.0
2.5
0.0027

0.0028

0.0029

0.0030

0.0031

0.0032

0.0033

0.0034

Inverse Temperature (1/K)

30
Heat of Adsorption (kJ/mole)

27 kJ/mole

25
20
15
10
5
0
0

10

15

20

25

30
3

Quantity of CO2 Adsorbed (cm /g)

35

40

P18775 Final Report

18
16

10C

14

15C
20C

Volume of N2 adsorbed (cm /g)

5C

12

25C

10
8
6
4
2
0
0

0.2

0.4

0.6
Pressure (atm)

0.8

1.2

P18775 Final Report

18
5C

16

Volume of O2 Adsorbed (cm3/g)

10C
14
15C
20C

12

25C

10
8
6
4
2
0
0

0.2

0.4

0.6
Pressure (atm)

0.8

1.2

P18775 Final Report

18
5C
10C

14

15C

Volume of Ar adsorbed (cm /g)

16

12

20C
25C

10
8
6
4
2
0
0

0.2

0.4

0.6
Pressure (atm)

0.8

1.2

P18775 Final Report

300
5C

Volume of H2O Vapor Adsorbed (cm3/g)

10C

250
15C
20C

200

30C

150

100

50

0
0

0.1

0.2

0.3
Relative Pressure (P/P0)

0.4

0.5

0.6

P18775 Final Report

3.0

SO2 adsorbed (cm 3/g)

2.5
2.0
1.5
1.0
0.5
0.0
0

0.2

0.4

0.6

0.8

1.2

SO2 pressure (torr)

Quantity Adsorbed (cm 3/g STP)

1.2
1.0
0.8
0.6
0.4
0.2
0.0
0

6
NO pressure (Torr)

10

12

P18775 Final Report

20

Heat of Adsorption (kJ/mole)

19
18
N2
17

O2
Ar

16
15
14
13
12
11
10
0

8
3

Volume of Gas Adsorbed (cm /g)

10

12

P18775 Final Report

50
45

Heat of Adsorption (kJ/mole)

40
35
30
25
20
15
10
5
0
0

50

100

150

200
3

Volume of H2O Vapor Adsorbed (cm /g)

250

P18775 Final Report

Table III-2. Physical Properties of the ACS-1 Sorbent

P18775 Final Report

P18775 Final Report

Table III-3. Attrition Resistance of the ACS-1 Sorbent

P18775 Final Report

P18775 Final Report

15
Blank Run
40% RH
Percent CO2 in the Reactor Exit

Empty
80% RH

0% RH

10

0
0

10

15

20

25

30

35

40

Time (min)

25.0
0% RH

CO2 Loading on the Sorbent (cm /g)

40% RH
20.0
80% RH

15.0

10.0

5.0

0.0
0

10

20
Time(min)

30

40

P18775 Final Report

50.00

40.00

Adsorbed Gas (cm /g)

5C

30.00
10 C
25 C

20.00

10.00

0.00
0

10

20

30

40
Nominal RH (%)

50

60

70

80

100

2000

90

1800

80

1600
Temperature (C)

Temperature (C)

70

1400

60

1200

50

1000

40

800

30

600

20

CO2 Flow Rate (cc/min)

P18775 Final Report

400
CO2 Flow Rate

10

200

0
80

85

90

95

100

105

0
110

Time (min)

CO2 Loading (cm3/g), Temperature (C)

120

100
CO2 Loading
80

Temperature

60
100 C
40

20

90 C

106 C

0
70

75

80

85
Time (min)

90

95

100

P18775 Final Report

110

140

109

120
100

Weight %

107
106

80

105
60

104
103

40

102
20

101
100

0
0

500

1000

Run time (min)

1500

Temperature (C)

108

P18775 Final Report

1700

Surface area (m 2/g)

1600
1500
1400
1300
1200
1100
1000
ACS1

ACS2

ACS3

9.5

Weight %

9.0
8.5
8.0
7.5
7.0
ACS1

ACS2

ACS3

P18775 Final Report

P18775 Final Report

Feed Hopper

Flue gas in

15% CO2

Sorbent flow

Adsorber

0% CO2

Rectifier
100% CO2

Stripper

1 bar steam
Receiving Hopper

Lean flue gas

P18775 Final Report

P18775 Final Report

P18775 Final Report

8
7

Granule velocity (in/sec)

6
5
4
3
2
1
0
0

10

15
Gas linear velocity (in/sec)

20

25

30

P18775 Final Report

1.4

Pressure Differential (inch of water)

1.2

0.8
Sorbent Flow
(0.3 gpm/ft^2)

0.6

0.4

0.2
No Sorbent Flow
0
0

10

20

30

40
Air Flow (SLM)

50

60

70

80

P18775 Final Report

18
16
14

Percent CO2

12
10
8
6
30 SLM
4

19 SLM

25 SLM

15 SLM

2
0
-100

20 SLM
10 SLM
-50

50

100
Time (sec)

150

200

250

300

P18775 Final Report

120

Capture Efficiency

100

80

Capacity predicted from


adsorption isotherm data

60

40

20

0
10

12

14

16

18

20

22

Gas feed rate (SLM)

24

26

28

30

P18775 Final Report

120

Percent captured

100

80

60

40

20

0
3

3.5

4.5

5.5

Residence time (sec)

6.5

P18775 Final Report

200

100

180

90
80

Percent desorbed

140

70

120

60

100

50

80

40

60

30
CO2 Flow Rate

40

20

20

10

0
0

10
Time (min)

12

14

16

18

20

Percent desorbed

CO2 flow (std cm /min)

160

P18775 Final Report

Transition

P18775 Final Report

CO2
Percent
Percent CO
2 in the Exit Gas
4

-100

-50

50

40

30

20

-50

50

50

100

100

150

150

200

200

Run Time (sec)


250

Run Time (sec)

100

90

80

70

60

10

250

300
350

300

350

Sorbent flow off

Sorbent flow off

Steam stripping off

Sorbent and steam flow on

Steam stripping off

-100

Sorbent flow on

CO2
Percent
Percent CO
2 in the Exit Gas

P18775 Final Report

16

14

12

10

400

400

450

450

P18775 Final Report

120

Temperature (C)

110

100

90

80

70

60
0

50

100

150

Run Time (sec)

200

250

P18775 Final Report

P18775 Final Report


100%
98%
96%

Product purity

94%
92%
90%
88%
86%
84%
82%
80%
0.0

0.2

0.4

0.6

0.8

1.0

1.2

1.4

1.0

1.2

1.4

CO2 product/feed ratio

100%
90%

Capture efficiency

80%
70%
60%
50%
40%
30%
20%
0.0

0.2

0.4

0.6

0.8

CO2 product/feed ratio

P18775 Final Report

100.0%
98.0%
96.0%
94.0%
92.0%

Capture efficiency
CO2 purity

90.0%
88.0%
86.0%
84.0%
82.0%
4

Gas residence time (sec)

P18775 Final Report

Vent

CO2 Depleted Air

Absorber

Simulated Flue Gas

Transition

Sorbent Return

CO2 Out

Regeneration

Steam

Transition
Air-CO2 Recirculation

Condenser

Dehydration

Cooling
Water
Sorbent
Dry AirCooling

P18775 Final Report

Absorber
12 ft
Rectifier
Transition

CO2 Stripper

Sorbent Cooler

P18775 Final Report

P18775 Final Report

P18775 Final Report

P18775 Final Report

P18775 Final Report

P18775 Final Report

P18775 Final Report

P18775 Final Report

P18775 Final Report

100
90

Quantity of CO2 absorbed (ml/g)

Fresh Granules
80
70
60

Granules after 1000-cycle test

50
40
30
20
10
0
0

100

200

300

400

500

600

CO2 Partial Pressure (Torr)

700

800

900

P18775 Final Report

100

% CO2 in the
Feed Gas

90

% CO2 in the
Output Gas

CO2 Concentration (%)

80
70

Startup

Steady-State Operation (~1 h)

Shut Down

60
50
40
30
20
10
0

~95% Capture

Run Time

% CO2 in the
Absorber Exit
Gas

P18775 Final Report

P18775 Final Report

Flue Gas
Chimney

Reactor
assembly

Figure VI-1. The integrated reactor installed at the University of Toledo boiler site.

P18775 Final Report

VENT
CO2
0-1%

CO2
0-20%

ABSORBER

FT
IDF

DPT

TRANSITION

TT

FI

NaHCO3

DESOx

FT

VENT
GAS
FILTER

BLOWER
TRAP

COOLING
WATER
TT
DCE

STRIPPER

TT

FLUE GAS

STEAM
STEAM OUT
SODIUM BICARBONATE
SOLUTION RESERVOIR

STEAM IN

ROTARY VALVE
AIR/
MOISTURE
STEAM OUT
STEAM IN
COOLING WATER OUT
DPT

COOLING WATER IN
AIR

SCREW FEEEDER
COMPRESSED AIR

CO2
0-100%

P18775 Final Report

Flue Gas
Chimney

Integrated
Reactor

Sorbent
Feed
Flue Gas
outlet Filter

Pneumatic
Feed Tube

Top of
Adsorber

Figure VI-4. A photograph of the sorbent inlet and flue gas outlet sections

P18775 Final Report

Stripper

Rotary Valve

Sorbent
Dehydrator

Sorbent Cooler

Screw Feeder

Pneumatic Pickup

P18775 Final Report

. Process Parameters and Their Values Used in the Field Test at the
University of Toledo

P18775 Final Report

10
% CO2 in Stripper Outlet Gas

CO2 Capture or CO2 in Stripper (%)

90
80

9
8

% CO2 Capture

70

60

50

% CO2 in Feed Gas

40

30

20

10

0
0

50

100

150
Time (Min)

200

250

0
300

Percentage CO2 in Feed Gas (%)

100

P18775 Final Report

% CO2 Capture or % CO2 Product Purity

120

Product CO2 Purity

100

Percent CO2 Capture

80

Interruption in Steam Flow


60

40

20

0
0

50

100

150

200
Time (Min)

250

300

350

400

P18775 Final Report

90

Cumualtive CO2 adsorbed (cm3/g-STP)

80
After 135 h of Testing
70
60

Fresh

50
40
30
20
10
0
0

100

200

300

400

500

CO2 Pressure (Torr)

600

700

800

900

P18775 Final Report

P18775 Final Report

. Comparison of Inorganic Elements in the Fresh and Field Test Sorbents

Element
Na
P
K
Ca
Mn
Fe
Zn
Cl
S
Hg

Fresh
ppm
102
80
74
41
<2
<2
<2
468
19
<0.06

Used
ppm
95
66
6
41
24
1234
15
611
132
0.31

. Comparison of Adsorbed Gases in the Fresh and Field Test Sorbents

Contaminant
Acetone
NO
CO2
Methylbutane
Methylisocyanide
Pentane
Benzene
Acetic Acid

Fresh
ppb
3.24
N.D.
N.D.
N.D.
N.D.
N.D.
N.D.
N.D.

Used
ppm
9.02
3210
758
19.6
67.1
30.1
40
284

P18775 Final Report

cheaper

Table VI-4. Design Parameters and Their Values Used in the Field Test at NCCC

P18775 Final Report

P18775 Final Report

P18775 Final Report

P18775 Final Report

P18775 Final Report

P18775 Final Report

P18775 Final Report

25.0

Output Signal (mA)

20.0

15.0

10.0

5.0

0.0
0

Differential Pressure (Inch Water)

10

12

P18775 Final Report

9.0
8.0
7.0
Signal (mA)

6.0
5.0
4.0
3.0
2.0
1.0
0.0
0

200

400

600

800

1000

CO2 Flow (Liters/min) at 20 C

16
14

Signal (mA)

12
10
8
6
4
2
0
0

20

40

60

80

100

Temperature (C)

120

140

160

P18775 Final Report

25

Signal (mA)

20

15

10

0
0

100

200

300

400

Air Flow (Liters/min) at 20 C

500

600

P18775 Final Report

P18775 Final Report

P18775 Final Report

P18775 Final Report

70

Percentage CO2 in Gas

60

50
CO2-Rich Product Gas
40

30

20
Flue Gas
10

CO2-Lean Flue Gas

0
0

20

40

60

80

100
Time (Minutes)

120

140

160

180

200

P18775 Final Report

NETL

SRI

CO2 Capture
Gross Power Output (kW)
Auxiliary Power Requirement (kW)
Net Power Output (kW)

No
580,260
30,110
550,150

Yes
663,445
117,450
545,995

No
581,034
31,016
550,018

Yes
679,911
129,485
550,426

Net Plant HHV Efficiency (%)


Net Plant HHV Heat Rate (Btu/kW-hr)
Coal Flowrate (lb/hr)
CO2 Emissions (lb/MWh)

39.1%
8,721
411,282
1,773

27.2%
12,534
586,627
254

38.9%
8,859
414,000
1,790

27.1%
12,590
594,000
252

Total Plant Cost ($ x 1000)


Total Plant Cost ($/kW)
LCOE (/kWh)

866,391
1,575
6.33

1,567,073
2,870
11.48

872,118
1,586
6.40

1,586,765
2,883
11.58

P18775 Final Report

P18775 Final Report

Water

SCR

Baghouse

Air

Induced
Draft Fans
Stack
Gas

FGD

Fly Ash

PC
Boiler

Air
Forced Draft Fans

Limestone
Slurry

Gypsum
Slurry

Hot Reheat
HP Steam
Cold
Reheat

Generator
HP
Turbine

LP
Turbine

LP Turbines

Air
Primary Air Fans

Condenser

Illinois #6

Bottom
Ash

Feedwater
Preheater
System

P18775 Final Report

Net Power Output, MW


Steam Cycle, (psig,F,F)
Coal
Condenser pressure, mmHg
Cooling water to condenser, F
Cooling water from condenser, F
Stack Temperature, F
SO2 Control
FGD Efficiency, % SO2 Removal
NOx Control
SCR Efficiency, % NOx Removal
Ammonia Slip, ppmv
Particulate Control
Fabric Filter Efficiency, % Ash Removal
Mercury Control
Mercury Removal Efficiency, %
CO2 Capture, %

SRI Supercritical Power Plant


550
3500,1100,1100
Illinois #6
50.8
67.5
94.5
131.0
Wet Limestone Forced Oxidation
98.0
Low NOx Burners w/OFA and SCR
86.0
2.0
Fabric Filter
99.8
Co-Benefit Capture
90.0
N/A

NETL Supercritical Power Plant


550
3500,1100,1100
Illinois #6
50.8
60
80
135.0
Wet Limestone Forced Oxidation
98.0
Low NOx Burners w/OFA and SCR
86.0
2.0
Fabric Filter
99.8
Co-Benefit Capture
90.0
N/A

NETL

SRI

CO2 Capture
Gross Power Output (kW)
Auxiliary Power Requirement (kW)
Net Power Output (kW)

No
580,260
30,110
550,150

No
581,034
31,016
550,018

Net Plant HHV Efficiency (%)


Net Plant HHV Heat Rate (Btu/kW-hr)
Coal Flowrate (lb/hr)
CO2 Emissions (lb/MWh)

39.1%
8,721
411,282
1,773

38.9%
8,859
414,000
1,790

Total Plant Cost ($ x 1000)


Total Plant Cost ($/kW)
LCOE (/kWh)

866,391
1,575
6.33

872,118
1,586
6.40

P18775 Final Report

P18775 Final Report

Condensate
Return
Water

SCR

Air

Induced
Baghouse Draft Fans
FGD

Fly Ash

PC
Boiler

Air
Forced Draft Fans

Limestone
Slurry

Gypsum
Slurry

Econamine
CO2 Capture

CO2
Compressor
Generator

HP
Turbine

LP
Turbine

LP Turbines

Air
Primary Air Fans

Condenser

Illinois #6

Bottom
Ash

CO2

Stripper
Steam

Hot Reheat
HP Steam
Cold
Reheat

Stack
Gas

Feedwater
Preheater
System

P18775 Final Report

Net Power Output, MW


Steam Cycle, (psig,F,F)
Coal
Condenser pressure, mmHg
Cooling water to condenser, F
Cooling water from condenser, F
Stack Temperature, F
SO2 Control
FGD Efficiency, % SO2 Removal
NOx Control
SCR Efficiency, % NOx Removal
Ammonia Slip, ppmv
Particulate Control
Fabric Filter Efficiency, % Ash Removal
Mercury Control
Mercury Removal Efficiency, %
CO2 Control
CO2 Capture, %
CO2 Sequestration

SRI Supercritical Power Plant


w/ Econamine FG+ CO2 Captue
550
3500,1100,1100
Illinois #6
50.8
64.5
85.5
74.0
Wet Limestone Forced Oxidation
98.0
Low NOx Burners w/OFA and SCR
86.0
2.0
Fabric Filter
99.8
Co-Benefit Capture
90.0
Econamine FG Plus
90
Off-site Saline Formation

NETL Supercritical Power Plant


w/ Econamine FG+ CO2 Captue
550
3500,1100,1100
Illinois #6
50.8
60
80
74.0
Wet Limestone Forced Oxidation
98.0
Low NOx Burners w/OFA and SCR
86.0
2.0
Fabric Filter
99.8
Co-Benefit Capture
90.0
Econamine FG Plus
90
Off-site Saline Formation

NETL

SRI

CO2 Capture
Gross Power Output (kW)
Auxiliary Power Requirement (kW)
Net Power Output (kW)

Yes
663,445
117,450
545,995

Yes
679,911
129,485
550,426

Net Plant HHV Efficiency (%)


Net Plant HHV Heat Rate (Btu/kW-hr)
Coal Flowrate (lb/hr)
CO2 Emissions (lb/MWh)

27.2%
12,534
586,627
254

27.1%
12,590
594,000
252

1,567,073
2,870
11.48

1,586,765
2,883
11.58

Total Plant Cost ($ x 1000)


Total Plant Cost ($/kW)
LCOE (/kWh)

P18775 Final Report

Parameter
Steam Turbine Gross Power
Auxiliary Load
Coal Handling & Conveying
Limestone Handling & Reagent Preparation
Pulverizers
Ash Handling
Primary Air Fans
Forced Draft Fans
Induced Draft Fans
SCR
Baghouse
FGD Pumps & Agitators
Econamine Plus Auxiliaries
CO2 Compressor
Miscellaneous Balance-of-Plant
Condensate Pumps
Circulating Water Pumps
Cooling Tower Fans
Transformer Losses
Auxillary Power Requirements
Total
Net Plant Performance
Auxiliary Load
Net Plant Power
Net Plant Efficiency (HHV)
Net Plant Heat Rate (HHV)
Coal Feed Flowrate
Thermal Input1
Limestone Sorbent Feed
CO2 Emitted

Unit
kWe

CO2 Captured

lb/hr

CO2 Removal
Water Requirement

lb/s

kWe
kWe
kWe
kWe
kWe
kWe
kWe
kWe
kWe
kWe
kWe
kWe
kWe
kWe
kWe
kWe
kWe
kWe
kWe
kWe
kWe
Btu/kWhr
lb/hr
kWth
lb/hr
lb/hr

No CO2 Capture
581,034

CO2 Capture with


Econamine
679,911

508
1,004
3,472
803
1,262
1,324
7,165
218
558
4,664
0
0
1,453
1,085
3,977
2,070
1,453

729
1,441
4,981
1,152
1,810
1,900
28,581
313
788
7,061
16,733
48,999
1,700
820
4,050
6,728
1,700

31,016

129,485

31,016
550,018
38.9%
8,859
414,000
1,415,453
41,089
984,315

129,485
550,426
27.1%
12,590
594,000
2,030,867
58,953
138,598

0.0%

1,247,382

0
707

90.0%
1,417

P18775 Final Report

P18775 Final Report

Condensate
Return
Water

SCR

Air

Induced
Baghouse Draft Fans
FGD

Fly Ash

PC
Boiler

Air
Forced Draft Fans

Limestone
Slurry

Hot Reheat
HP Steam
Cold
Reheat

Gypsum
Slurry

Carbon
Sorbent
CO2 Capture

CO2
Stripper
Steam

Primary Air Fans

LP
Turbine

LP Turbines

Condenser

Bottom
Ash

CO2
Compressor
Generator

HP
Turbine

Air

Illinois #6

Stack
Gas

Feedwater
Preheater
System

P18775 Final Report

Net Power Output, MW


Steam Cycle, (psig,F,F)
Coal
Condenser pressure, mmHg
Cooling water to condenser, F
Cooling water from condenser, F
Stack Temperature, F
SO2 Control
FGD Efficiency, % SO2 Removal
NOx Control
SCR Efficiency, % NOx Removal
Ammonia Slip, ppmv
Particulate Control
Fabric Filter Efficiency, % Ash Removal
Mercury Control
Mercury Removal Efficiency, %
CO2 Control
CO2 Capture, %
CO2 Sequestration

SRI Supercritical Power Plant


w/ Carbon Sorbent CO2 Captue
550
3500,1100,1100
Illinois #6
50.8
64.5
85.5
74.0
Wet Limestone Forced Oxidation
98.0
Low NOx Burners w/OFA and SCR
86.0
2.0
Fabric Filter
99.8
Co-Benefit Capture
90.0
Econamine FG Plus
90
Off-site Saline Formation

Base Case

NETL Supercritical Power Plant


w/ Econamine FG+ CO2 Captue
550
3500,1100,1100
Illinois #6
50.8
60
80
74.0
Wet Limestone Forced Oxidation
98.0
Low NOx Burners w/OFA and SCR
86.0
2.0
Fabric Filter
99.8
Co-Benefit Capture
90.0
Econamine FG Plus
90
Off-site Saline Formation

Econamine FG+

Carbon Sorbent

CO2 Capture
Gross Power Output (kW)
Auxiliary Power Requirement (kW)
Net Power Output (kW)

No
581,034
31,016
550,018

Yes
679,911
129,485
550,426

Yes
640,421
90,246
550,175

Net Plant HHV Efficiency (%)


Net Plant HHV Heat Rate (Btu/kW-hr)
Coal Flowrate (lb/hr)
CO2 Emissions (lb/MWh)

38.9%
8,859
414,000
1,790

27.1%
12,590
594,000
252

35.1%
9,717
458,280
194

Total Plant Cost ($ x 1000)


Total Plant Cost ($/kW)
LCOE (/kWh)
Increase in COE (%)

872,118
1,586
6.40
0.0%

1,586,765
2,883
11.58
80.9%

1,224,213
2,225
9.23
44.2%

101

P18775 Final Report

Parameter

Units

CO2 Capture by
Carbon Sorbent
Econamine
640,415
679,911

Steam Turbine Gross Power


Auxiliary Load
Coal Handling & Conveying
Limestone Handling & Reagent Preparation
Pulverizers
Ash Handling
Primary Air Fans
Forced Draft Fans
Induced Draft Fans
SCR
Baghouse
FGD Pumps & Agitators
Carbon Sorbents/Econoamine Plus Auxiliaries
CO2 Compressor
Miscellaneous Balance-of-Plant
Condensate Pumps
Circulating Water Pumps
Cooling Tower Fans
Transformer Losses

kWe
kWe
kWe
kWe
kWe
kWe
kWe
kWe
kWe
kWe
kWe
kWe
kWe
kWe
kWe
kWe
kWe
kWe

563
1,112
3,844
889
1,397
1,466
13,528
241
615
5,246
5,484
41,966
1,601
1,053
5,002
4,638
1,601

729
1,441
4,981
1,152
1,810
1,900
28,581
313
788
7,061
16,733
48,999
1,700
820
4,050
6,728
1,700

Total

kWe

90,246

129,485

Auxiliary Load
Net Plant Power
Net Plant Efficiency (HHV)
Net Plant Heat Rate (HHV)
Coal Feed Flowrate
Thermal Input1
Limestone Sorbent Feed
CO2 Emitted

kWe
kWe

90,246
550,170
35.1%
9,718
458,280
1,566,845
45,483
106,944

129,485
550,426
27.1%
12,590
594,000
2,030,867
58,953
138,598

CO2 Captured

lb/hr

962,496

1,247,382

90.0%
917

90.0%
1,417

Net Plant Performance

CO2 Removal
Water Requirement

Btu/kWhr
lb/hr
kWth
lb/hr
lb/hr

pounds/s

102

P18775 Final Report

103

P18775 Final Report

Parameter
Reboiler Steam Pressure
Flue Gas Pressure Drop
Reboiler Heat Input
Max Absorber Inlet Temperature
Absorbent CO2 Capacity
CO2 Capture Capital Cost
Net Plant HHV Efficiency
Gross Plant Output
Coal Flowrate

Units
psia
psia
BTU/lb-CO2
F
wt%
$/(lb/hr-CO2)
%
MW
tons/hr

Power Plant Capital


Power Plant Fuel
Variable Plant O&M
Fixed Plant O&M
CO2 Transport, Monitoring, & Storage

c/kWh

Cost of Electricity (COE)


Increase in COE

c/kWh

c/kWh
c/kWh
c/kWh
c/kWh
%

Base Case
17.7
0.54
250

Reboiler
Reboiler Flue Gas Flue Gas
Steam
Steam
Pressure Pressure Reboiler
Reboiler
Pressure Pressure
Drop
Drop
Heat Input Heat Input
53.1
131.1
17.7
17.7
17.7
17.7
0.5
0.5
1.0
2.0
0.5
0.5
250
250
250
250
350
500

70
6.7%
191

70
6.7%
191

70
6.7%
191

70
6.7%
191

70
6.7%
191

70
6.7%
191

70
6.7%
191

35.1%
640
458

34.8
641
463

34.5
642
467

34.9
644
461

34.5
653
467

34.8
641
462

34.4
643
468

5.23
2.11
0.93
0.58
0.38
9.23
44.2%

5.28
2.13
0.93
0.58
0.38
9.30
45.3%

5.33
2.15
0.94
0.58
0.38
9.38
46.6%

5.26
2.12
0.93
0.58
0.38
9.28
45.0%

5.33
2.15
0.94
0.58
0.38
9.38
46.6%

5.27
2.13
0.93
0.58
0.38
9.30
45.3%

5.34
2.15
0.94
0.58
0.38
9.39
46.7%

104

P18775 Final Report

Parameter
Reboiler Steam Pressure
Flue Gas Pressure Drop
Reboiler Heat Input
Max Absorber Inlet Temperature
Absorbent CO2 Capacity
CO2 Capture Capital Cost

Units

Base Case
17.7
0.54
250
70
wt%
6.7%
$/(lb/hr-CO2)
191

psia
psia
BTU/lb-CO2
F

Absorbent Absorbent
Max
Max
CO2
CO2
Absorb.
Absorb.
Inlet Temp Inlet Temp Capacity Capacity
17.7
17.7
17.7
17.7
0.5
0.5
0.5
0.5
250
250
250
250
50
100
70
70
6.7%
6.7%
10.0%
5.0%
191
191
191
191

CO2
Capture
Capital
Cost
17.7
0.5
250
70
6.7%
96

CO2
Capture
Capital
Optimized
Cost
Case
17.7
17.7
0.5
0.5
250
250
70
50
6.7%
10.0%
127
96

Net Plant HHV Efficiency


Gross Plant Output
Coal Flowrate

%
MW
tons/hr

35.1%
640
458

34.9
645
461

35.1
640
458

35.1
640
458

35.0
643
460

35.1
640
458

35.1
640
458

34.9
645
461

Power Plant Capital


Power Plant Fuel
Variable Plant O&M
Fixed Plant O&M
CO2 Transport, Monitoring, & Storage
Cost of Electricity (COE)
Increase in COE

c/kWh
c/kWh
c/kWh
c/kWh

5.23
2.11
0.93
0.58
0.38
9.23
44.2%

5.26
2.12
0.93
0.58
0.39
9.28
44.9%

5.23
2.11
0.93
0.58
0.38
9.22
44.1%

5.23
2.11
0.93
0.58
0.38
9.22
44.1%

5.25
2.12
0.93
0.58
0.38
9.26
44.7%

4.47
2.11
0.93
0.58
0.38
8.47
32.3%

4.72
2.11
0.93
0.58
0.38
8.72
36.3%

4.50
2.12
0.93
0.58
0.39
8.50
32.8%

c/kWh
c/kWh
%

105

P18775 Final Report

. Characteristics of the CO2 Capture System


Units

Original
17.7
0.54
250
70
10
$/(lb/hr-CO2)
96

Parameter
Reboiler Steam Pressure
Flue Gas Pressure Drop
Reboiler Heat Input
Max Absorber Inlet Temperature
Absorbent CO2 Capacity
CO2 Capture Capital Cost

psia
psia
BTU/lb-CO2
F
wt%

106

Revised
17.7
1
500
70
5
96

P18775 Final Report

. Characteristics of a Supercritical Power Plant with CO2 Capture

Net Power Output, MW


Steam Cycle, (psig,F,F)
Coal
Condenser pressure, mmHg
Cooling water to condenser, F
Cooling water from condenser, F
Stack Temperature, F
SO2 Control
FGD Efficiency, % SO2 Removal
NOx Control
SCR Efficiency, % NOx Removal
Ammonia Slip, ppmv
Particulate Control
Fabric Filter Efficiency, % Ash Removal
Mercury Control
Mercury Removal Efficiency, %
CO2 Control
CO2 Capture, %
CO2 Sequestration

SRI Supercritical Power Plant with


Carbon Sorbent CO2 Captue

NETL Supercritical Power Plant


with Econamine FG+ CO2 Captue

550

550

3500,1100,1100

3500,1100,1100

Illinois #6

Illinois #6

50.8

50.8

64.5

60

85.5

80

74.0

74.0

Wet Limestone Forced Oxidation

Wet Limestone Forced Oxidation

98.0

98.0

Low NOx Burners w/OFA and SCR

Low NOx Burners w/OFA and SCR

86.0

86.0

2.0

2.0

Fabric Filter

Fabric Filter

99.8

99.8

Co-Benefit Capture

Co-Benefit Capture

90.0

90.0

Advanced Carbon Sorbent

Econamine FG Plus

90

90

Off-site Saline Formation

Off-site Saline Formation

107

P18775 Final Report

. Auxiliary Loads and Power Plant Performance

Parameter
Steam Turbine Gross Power
Auxiliary Load
Coal Handling & Conveying

CO2 Capture
CO2 Capture
with Economine with the Carbon
No CO2 Capture
FG+
Sorbent
580,400
662,800
642,113

Unit
kW e
kW e

440

510

556

Limestone Handling & Reagent Prep

kW e

890

1,250

1,078

Pulverizers

kW e

2,780

3,850

3,703

Ash Handling

kW e

530

740

860

Primary Air Fans

kW e

1,300

1,800

1,342

Forced Draft Fans

kW e

1,660

2,300

1,410

Induced Draft Fans

kW e

7,050

11,120

17,020

SCR

kW e

50

70

253

Baghouse

kW e

70

100

642

FGD Pumps & Agitators

kW e

2,970

4,110

5,047

Econamine FG Plus Auxiliaries

kW e

20,600

6,000

CO2 Compressor

kW e

44,890

43,274

Miscellaneous Balance-of-Plant

kW e

2,000

2,000

2,395

Steam Turbine Auxiliaries

kW e

400

400

Condensate Pumps

kW e

800

560

811

Circulating Water Pumps

kW e

4,730

10,100

4,376

Ground Water Pumps

kW e

480

910

4,477

Cooling Tower Fans

kW e

2,440

5,230

1,588

Transformer Losses

kW e

1,820

2,290

3,922

Total

kW e

30,410

112,830

98,751

Net Plant Performance


Auxiliary Load

kW e

30,410

112,830

98,751

kW e

549,990
39.3%
8,687
409,528
1,400,163
40,646
972,382

549,970
28.4%
12,002
565,820
1,934,520
57,245
134,193

543,362
36.0%
9,472
441,178
1,508,374
43,508
102,924

0
90.0%
4,252

1,207,730
90.0%
7,300

926,317
90.0%
7,072

Net Plant Power


Net Plant Efficiency (HHV)
Net Plant Heat Rate (HHV)
Coal Feed Flowrate
Thermal Input
Limestone Sorbent Feed
CO2 Emitted
CO2 Captured
CO2 Removal
Water Requirement

Btu/kWhr
lb/hr
kW th
lb/hr
lb/hr
lb/hr
1000s gpd

108

P18775 Final Report

. Cost of CO2 Capture

Parameter
Capacity Factor
Capital Charge Factor
20-year Levelization Factors
Fuel
Non-Fuel Variable O&M
Fixed O&M
Plant Operating Life
Power Production @100% Capacity
Power Plant Capital
Power Plant Fuel
Variable Plant O&M
Fixed Plant O&M
Power Plant Total
CO2 TS&M
BOTTOM LINE TOTAL
Increase in COE
CO2 Emissions

CO2 Capture
CO2 Capture
with Economine with the Carbon
No CO2 Capture
FG+
Sorbent
85%
85%
85%
11.65%
12.43%
12.43%

Unit

1.2089
1.1618
1.1618

1.2089
1.1618
1.1618

1.2089
1.1618
1.1618

years
GWh/yr

30
4,818

30
4,818

30
4,760

c/kWh
c/kWh
c/kWh
c/kWh
c/kWh
c/kWh
c/kWh

3.17
1.42
0.51
0.80
5.89
5.89

5.96
1.96
0.87
1.30
10.10
0.56
10.66

4.40
1.55
0.66
0.96
7.56
0.54
8.10

0.0%

80.2%

37.2%

lb/MWh

1,768

244

189

109

P18775 Final Report

110

P18775 Final Report

1. The performance of the process will be demonstrated using a flue gas stream
from an operating PC-fired power plant for an extended period of time.
2. The system design will focus on the materials of construction to reduce the
cost of CO2 capture to acceptable levels. The capital cost of the system is a
major factor in the cost of CO2 capture.
3. Thermal integration concepts can be evaluated at a preliminary level.
Although thermal requirements cannot be defined precisely at this scale, we
will obtain a reasonable estimate of steam requirements, which is a major
operating cost.

111

P18775 Final Report

112

You might also like