Professional Documents
Culture Documents
Product/Manual Catalog
Contents
Introduction
S.L.A. Surface
SuperLine Characteristics
SuperLine Color Coding by Diameter
SuperLine Fixture
IMPLANTIUM Characteristics
IMPLANTIUM Color Coding by Diameter
IMPLANTIUM Fixture
Surgical Components
Cover Screw
Healing Abutment
04
06
08
09
12
14
15
Prosthetic Procedure 3
38
39
40
41
Prosthetic Procedure 4
Overdenture Procedure
- Positioner / Mini Ball / Magnetic Attachment
16
17
Prosthetic Procedure 1
Combi Abutment
19
Dual Abutment [Hex] 20
Dual Abutment [Non-hex] 21
Abutment Level Impression Components
22
Restorative Kit
23
44
Positioner 45
Mini Ball Attachment
47
Magnetic Attachment (Dome Type)
48
Magnetic Attachment (Flat Type)
49
Instruments
04
S.L.A. Surface
S.L.A. (Sandblasting with large grit and acid etching)
In vivo test
06
SuperLine Characteristics
"Immediate Implantation with Excellent Bone Response"
Higher stabilization in extraction socket
Early loading in upper posterior
Harmony with anatomy
Sharp & fast insertion
Abutment
Platform
Abutment Height
Abutment
G/H
Bevel
Fixture Length
A
Body
Selection Guideline
Ideal emergence profile for each tooth
07
SuperLine Characteristics
A Tapered Design
Tapered load distribution may achieve excellent
bone response.
Tapered design may harmonize with surrounding
bone anatomically.
The large surface area helps provide excellent
initial stability with sinus augmentation.
B Biological Connection
C-2 Osseointegration
D Prosthesis
Dual
Milling
Angled
Direct
Screw
08
Cap Color
Yellow
Green
Blue
Red
Orange
Violet
3.7
4.0
4.5
5.0
6.0
7.0
3.6
4.0
4.5
5.0
5.0
5.8
1.5
1.5
1.5
1.5
1.5
1.5
0.1
0.3
0.4
0.7
1.0
Fixture
SuperLine
(Mount Free)
Platform
Fixture
Platform
Diameter
Fixture
Body
Diameter
Body
Bevel
L:7
Fixture
Bevel
Height
Bevel
L : 8, 10,
12, 14
Fixture
Bevel
Height
09
SuperLine Fixture
Unit: mm, Scale 1 : 1.5 / mm
3.7
Art. No.
FXS 36 07
FXS 36 08
10
FXS 36 10
12
FXS 36 12
14
FXS 36 14
Art. No.
FXS 40 07
FXS 40 08
10
FXS 40 10
12
FXS 40 12
14
FXS 40 14
Art. No.
FXS 45 07
FXS 45 08
10
FXS 45 10
12
FXS 45 12
14
FXS 45 14
Art. No.
FXS 50 07
FXS 50 08
10
FXS 50 10
12
FXS 50 12
14
FXS 50 14
12
14
3.6
4.0
07
08
1.5
0.1
10
0.1
12
0.1
14
0.1
4.0
4.5
07
08
1.5
0.3
10
0.3
12
0.3
14
0.3
4.5
5.0
10
08
1.5
07
07
1.5
08
0.4
10
5.0
Note: 1) To prevent damage to the Implant driver or fixture, do not over torque during fixture insertion
0.4
12
0.4
14
0.4
10
SuperLine Fixture
Unit: mm, Scale 1 : 1.5 / mm
6.0
Art. No.
FXS 60 07
FXS 60 08
10
FXS 60 10
FXS 60 12
12
Art. No.
FXS 70 07
FXS 70 08
10
FXS 70 10
FXS 70 12
12
1.5
08
0.7
10
0.7
12
0.7
5.0
7.0
07
5.8
07
1.5
08
1.0
10
1.0
12
1.0
12
Implantium Characteristics
Abutment
Platform
Abutment Height
Maximum
Reduction Line
Abutment
G/H
Bevel
Neck
E
Fixture Length
D
A
Final Drill
Body
Selection Guideline
Ideal emergence profile for each tooth
13
Implantium Characteristics
A Longer and Upgraded Cutting
Edge
C Biological Connection
D Biological Thread
Thread
platform design creates excellent bone to
implant contact.
initial stability through longer and sharper
Enhanced
threading
G Maintained Compatibility
Prosthetic
components and Surgical Kit 100%
14
Cap Color
Yellow
Green
Blue
Red
Fixture
Platform
Diameter
3.6
4.0
4.5
5.0
Fixture
Body
Diameter
3.6
4.0
4.5
5.0
Fixture
Bevel
Height
0.15
0.11
0.25
0.4
Fixture
Implantium
(Mount Free)
Platform
Body
Bevel
15
Implantium Fixture
Unit: mm, Scale 1 : 1.5 / mm
Art. No.
FXI 36 08
10
FXI 36 10
12
FXI 36 12
14
FXI 36 14
3.6
08
10
12
14
08
10
12
14
08
10
12
14
08
10
12
14
L
3.6
Art. No.
FXI 40 08
10
FXI 40 10
12
FXI 40 12
14
FXI 40 14
4.0
L
4.0
Art. No.
FXI 45 08
10
FXI 45 10
12
FXI 45 12
14
FXI 45 14
4.5
L
4.5
Art. No.
FXI 50 08
10
FXI 50 10
12
FXI 50 12
14
FXI 50 14
5.0
L
5.0
Note: 1) To prevent damage to the Implant driver or fixture, do not over torque during fixture insertion
16
Cover Screw
Single use only
4.5
3.6
3.6
Color: Green
Art. No.
CS36
Healing Abutment
Single use only
G/H 3.0
4.5
H 5.0
Hex driver: Use no more than 5Ncm torque when screwing a cover screw to a fixture.
If hex is worn, slot on the head of the product can be used to rotate it.
17
G/H
Art. No.
3.5
GBHAB 33 35
0.5
GBHAB 38 05
GBHAB 38 20
2.0
2.0
3.8
3.8
3.5
2.0
0.5
Diameter 4.0
G/H
Art. No.
2.0
2.0
HAB 40 20 20 L
2.0
3.5
HAB 40 20 35 L
3.0
5.0
HAB 40 30 50 L
4.0
7.0
HAB 40 40 70 L
4.0
2.0
3.5
2.0
4.0
4.0
4.0
5.0
3.0
7.0
4.0
Diameter 4.5
G/H
Art. No.
2.0
2.0
HAB 45 20 20 L
2.0
3.5
HAB 45 20 35 L
3.0
5.0
HAB 45 30 50 L
4.0
7.0
HAB 45 40 70 L
4.5
2.0
3.5
2.0
4.5
4.5
4.5
5.0
3.0
7.0
4.0
Diameter 5.5
G/H
Art. No.
2.0
2.0
HAB 55 20 20 L
2.0
3.5
HAB 55 20 35 L
3.0
5.0
HAB 55 30 50 L
4.0
7.0
HAB 55 40 70 L
5.5
5.5
2.0
3.5
2.0
5.5
5.5
5.0
3.0
7.0
4.0
Diameter 6.5
G/H
Art. No.
2.0
2.0
HAB 65 20 20 L
2.0
3.5
HAB 65 20 35 L
3.0
5.0
HAB 65 30 50 L
4.0
7.0
HAB 65 40 70 L
2.0
G/H
Art. No.
3.0
5.0
HAB 75 30 50 L
3.0
5.0
HAB 85 30 50 L
5.0
HAB 95 30 50 L
3.0
6.5
6.5
7.5
3.0
8.5
5.0
3.0
Hex driver: Use no more than 10Ncm of torque when screwing a healing abutment to a fixture.
If hex is worn, slot on the head of the product can be used to rotate it.
7.0
5.0 4.0
3.5 3.0
2.0
6.5
6.5
9.5
5.0
3.0
5.0
18
Prosthetic Procedure 1
Impression Technique and Restoration Selection
Combi Abutment
Dual Abutment
Page 19
Page 20, 21
Impression Coping
Analog
Analog
Page 22
Page 22
Burn-out Cylinder
Bridge
Single
Rotational
Non-rotational
Page 22
Page 22
Modification
Cemented Restoration
19
Combi Abutment
Unit: mm, Scale 1 : 1 / mm
5.5
5.5
1.5
5.5
4.0
G/H 3.5
G/H 3.5
Diameter 4.5
Type
G/H
G/H
1.0
3.5
4.5
CAB 45 45 SL
CAB 45 45 L
5.5
CAB 45 55 SL
CAB 45 55 L
1.5
2.5
3.5
4.5
5.5
Art. No
4.0
CAB 45 10 SL
CAB 45 10 L
G/H
1.5
CAB 45 15 SL
CAB 45 15 L
2.5
CAB 45 25 SL
Short
Art. No.
Type
1.0
CAB 45 35 SL
Long
CAB 45 25 L
Diameter 5.5
G/H
1.5
2.5
Type
G/H
G/H
Art. No.
Type
CAB 55 15 SL
Short
5.5
CAB 45 35 L
CAB 55 25 SL
CAB 55 35 SL
Long
1.5
2.5
3.5
4.5
5.5
Art. No
4.0
CAB 55 15 L
G/H
CAB 55 25 L
3.5
4.5
CAB 55 45 SL
CAB 55 35 L
CAB 55 45 L
5.5
5.5
CAB 55 55 SL
CAB 55 55 L
G/H
Diameter 6.5
Type
G/H
Type
2.5
3.5
4.5
5.5
G/H
Art. No
4.0
1.5
CAB 65 15 SL
CAB 65 15 L
G/H
2.5
CAB 65 25 SL
CAB 65 25 L
3.5
4.5
CAB 65 45 SL
CAB 65 45 L
5.5
5.5
CAB 65 55 SL
CAB 65 55 L
G/H
Short
Art. No.
1.5
CAB 65 35 SL
Long
CAB 65 35 L
Note: 1) If the Implantium fixture with size of 3.4 body is used, abutment height after assembly will become 0.5mm longer
than other sized fixtures.
2) It is recommended to keep the torque level at 25~30 Ncm to tighten the combi abutment with fixture.
20
5.5
1.5
5.5
G/H 3.5
G/H
Art. No.
1.0
DAB 45 10 HL
1.5
DAB 45 15 HL
2.5
DAB 45 25 HL
3.5
DAB 45 35 HL
4.5
DAB 45 45 HL
5.5
DAB 45 55 HL
G/H
1.0
1.5
2.5
3.5
4.5
5.5
5.5
G/H
G/H
Art. No.
1.5
DAB 55 15 HL
2.5
DAB 55 25 HL
3.5
DAB 55 35 HL
4.5
DAB 55 45 HL
5.5
DAB 55 55 HL
G/H
1.5
2.5
3.5
4.5
5.5
5.5
G/H
G/H
Art. No.
1.5
DAB 65 15 HL
2.5
DAB 65 25 HL
3.5
DAB 65 35 HL
4.5
DAB 65 45 HL
5.5
DAB 65 55 HL
G/H 1.5
2.5
3.5
4.5
5.5
5.5
G/H
Note: 1) If the Implantium fixture with size of 3.4 body is used, abutment height after assembly will become 0.5mm longer
than other sized fixtures.
2) It is recommended to keep the torque level at 25~30 Ncm to tighten the dual abutment with fixture.
21
5.5
1.5
5.5
G/H 3.5
G/H
Art. No.
1.0
DAB 45 10 NL
1.5
DAB 45 15 NL
2.5
DAB 45 25 NL
3.5
DAB 45 35 NL
4.5
DAB 45 45 NL
5.5
DAB 45 55 NL
G/H
1.0
1.5
2.5
3.5
4.5
5.5
5.5
G/H
G/H
Art. No.
1.5
DAB 55 15 NL
2.5
DAB 55 25 NL
3.5
DAB 55 35 NL
4.5
DAB 55 45 NL
5.5
DAB 55 55 NL
G/H
1.5
2.5
3.5
4.5
5.5
5.5
G/H
G/H
Art. No.
1.5
DAB 65 15 NL
2.5
DAB 65 25 NL
3.5
DAB 65 35 NL
4.5
DAB 65 45 NL
5.5
DAB 65 55 NL
G/H
1.5
2.5
3.5
4.5
5.5
5.5
G/H
Note: 1) If the Implantium fixture with size of 3.4 body is used, abutment height after assembly will become 0.5mm longer
than other sized fixtures.
2) It is recommended to keep the torque level at 25~30 Ncm to tighten the dual abutment with fixture.
22
Type
Diameter
Art. No.
4.5 CCC 45 CS
Short
5.5
6.5 CCC 65 CS
4.5
CCC 45 C
Long
5.5
CCC 55 C
6.5
CCC 65 C
4.5
5.5
6.5
4.8
CCC 55 CS
6.8
Impression Coping
Diameter
Art. No.
4.5 CIC 45 L
5.5 CIC 55 L
6.5 CIC 65 L
Lab Analog
Type
Diameter
Art. No.
4.5 CAN 45 SL
Short
5.5
6.5 CAN 65 SL
4.5
CAN 45 LL
Long
5.5
CAN 55 LL
6.5
CAN 65 LL
4.5
5.5
6.5
10.4
4.5
5.5
6.5
4.0
12.0
CAN 55 SL
5.5
12.0
Burn-out Cylinder
Type
Diameter
Art. No.
4.5 CBC 45 SL
Single
5.5
6.5 CBC 65 SL
4.5
CBC 45 BL
Bridge
5.5
CBC 55 BL
6.5
CBC 65 BL
CBC 55 SL
4.5
5.5
6.5
12.8
12.8
Restorative Kit
CAN 45 SL
CIC 45 L
XSDAB 45 CCC 45 C CAN 45 LL
CBC 45 SL CBC 45 BL
XSDAB 55 S CCC 55 CS
CAN 55 SL
CIC 55 L
CBC 55 SL CBC 55 BL
XSDAB 55 CCC 55 C CAN 55 LL
XSDAB 65 S CCC 65 CS
CAN 65 SL
CIC 65 L
XSDAB 65 CCC 65 C CAN 65 LL
CBC 65 SL CBC 65 BL
23
24
Prosthetic Procedure 2
Impression Technique and Restoration Selection
Non-hex
Open
Hex
Non-hex
Closed
Page 25
Page 26
Analog
DAN 34 / DANSE
Page 25, 26
Dual
Abutment
Custom
Abutment
Dual Milling
Abutment
4.5 / 5.5
4.0 / 4.5
5.5 / 6.5 / 7.5
Hex / Non-hex
Hex / Non-hex
Page 20, 21
Page 27
Angled
Abutment
Hex / Non-hex
Hex / Non-hex
Page 28, 30
15 / 25
4.5 / 5.5
Modification
Cemented
Restoration
Modification
Direct-Casting
Abutment
Metal-Casting
Abutment
4.5
4.5
Page 36
Page 37
Hex / Non-hex
Page 36
Hex / Non-hex
Temporary
Abutment
Hex / Non-hex
Screw-Retained
Restoration
25
Size
Type
Art. No.
Size
Type
Art. No.
Short
Hex DPU 40 11 HL
Short
Hex DPU 45 11 HL
Short
Non-hex DPU 40 11 NL
Short
Non-hex DPU 45 11 NL
Long
Hex DPU 40 15 HL
Long
Hex DPU 45 15 HL
Long
Non-hex DPU 40 15 NL
Long
Non-hex DPU 45 15 NL
4.0
4.0
4.0
Non-hex
Hex
4.5
Hex
4.5
4.5
21.0
21.0
17.0
17.0
Non-hex
Hex
4.5
21.0
21.0
17.0
17.0
4.0
Non-hex
Non-hex
Hex
Size
Type
Art. No.
Size
Type
Art. No.
Short
Hex DPU 55 11 HL
Short
Hex DPU 65 11 HL
Short
Non-hex DPU 55 11 NL
Short
Non-hex DPU 65 11 NL
Long
Hex DPU 55 15 HL
Long
Hex DPU 65 15 HL
Long
Non-hex DPU 55 15 NL
Long
Non-hex DPU 65 15 NL
5.5
5.5
5.5
Non-hex
Hex
6.5
21.0
21.0
17.0
17.0
Hex
5.5
6.5
Hex
Non-hex
6.5
21.0
21.0
17.0
17.0
Non-hex
6.5
Hex
Non-hex
Analog
Art. No.
Application (Body)
Art. No.
3.4(Only Implantium)
DAN 34
Size
Short
DPS 11
Long
DPS 15
DANSE
4.5
Short
23.0
Long
27.0
12.0
12.0
26
Size
Type
Short
Short
Long
Type
Short
DTF 40 11 NL
Short
Hex DTF 40 15 HL
Long
DTF 40 15 NL
Long
Non-hex
4.0
11.0
Hex
Size
Hex DTF 40 11 HL
Non-hex
Long
4.0
Art. No.
4.0
4.0
15.0
15.0
11.0
Non-hex
4.5
Hex DTF 45 11 HL
Hex DTF 45 15 HL
DTF 45 15 NL
Non-hex
4.5
Hex
DTF 45 11 NL
Non-hex
4.5
4.5
Non-hex
15.0
15.0
11.0
11.0
Non-hex
Hex
Art. No.
Non-hex
Hex
Size
Type
Short
Short
Long
Type
Short
DTF 55 11 NL
Short
Hex DTF 55 15 HL
Long
DTF 55 15 NL
Long
Non-hex
5.5
11.0
Hex
Size
Hex DTF 55 11 HL
Non-hex
Long
5.5
Art. No.
5.5
5.5
15.0
15.0
11.0
Non-hex
Hex
6.5
Hex DTF 65 11 HL
Hex DTF 65 15 HL
DTF 65 15 NL
Non-hex
6.5
Hex
DTF 65 11 NL
Non-hex
11.0
Non-hex
Art. No.
6.5
15.0
15.0
11.0
Non-hex
6.5
Hex
Non-hex
Analog
Size
Art. No.
Application (Body)
Art. No.
Short
DTS 11
DAN 34
Long
DTS 15
DANSE
4.0
4.5
Short
17.0
Long
21.0
12.0
12.0
27
Custom Abutment
Abutment screw is included.
5.5
Top view
5.5
4.5
G/H 1.0
5.5
Diameter 4.5
G/H
Type
Art. No.
0.5
Hex
CDAB 45 05 H
0.5
Non-hex
CDAB 45 05 N
Hex
CDAB 45 15 H
Non-hex
CDAB 45 15 N
1.5
1.5
4.5
4.5
0.5
4.5
4.5
1.5
0.5
1.5
Hex
Non-hex
Hex
Non-hex
5.5
5.5
5.5
5.5
Diameter 5.5
G/H
Type
Art. No.
1.0
Hex
CDAB 55 10 H
1.0
Non-hex
CDAB 55 10 N
Hex
CDAB 55 20 H
Non-hex
CDAB 55 20 N
2.0
2.0
1.0
Hex
2.0
1.0
Non-hex
Hex
2.0
Non-hex
Note: 1) If the Implantium fixture with size of 3.4 body is used, abutment height after assembly will become 0.5mm longer
than other sized fixtures.
2) It is recommended to keep the torque level at 25~30 Ncm to tighten the custom abutment with fixture.
28
5.5
12
G/H 1.5
Diameter 4.0
4.0
4.0
G/H
Type
Art. No.
1.0
Hex
DAB 40 105 HL
1.0
Non-hex
DAB 40 105 NL
1.0
Diameter 4.5
G/H
Type
1.5
Hex
DAB 45 156 HL
1.5
Non-hex
DAB 45 156 NL
1.0
Hex
Non-hex
4.5
4.5
Art. No.
1.5
1.5
Hex
Non-hex
5.5
5.5
Diameter 5.5
G/H
Type
1.5
Hex
DAB 55 157 HL
1.5
Non-hex
DAB 55 157 NL
Hex
DAB 55 257 HL
Non-hex
DAB 55 257 NL
2.5
2.5
Art. No.
5.5
1.5
Hex
1.5
Non-hex
5.5
2.5
Hex
2.5
Non-hex
Note: 1) If the Implantium fixture with size of 3.4 body is used, abutment height after assembly will become 0.5mm longer
than other sized fixtures.
2) It is recommended to keep the torque level at 25~30 Ncm to tighten the dual milling abutment with fixture.
29
Diameter 6.5
G/H
Type
Art. No.
1.5
Hex
DAB 65 158 HL
1.5
Non-hex
DAB 65 158 NL
Hex
DAB 65 258 HL
Non-hex
DAB 65 258 NL
Hex
DAB 65 358 HL
Non-hex
DAB 65 358 NL
2.5
2.5
3.5
3.5
6.5
6.5
6.5
1.5
Hex
2.5
2.5
1.5
Non-hex
6.5
Hex
Non-hex
6.5
6.5
3.5
3.5
Hex
Non-hex
7.5
7.5
Diameter 7.5
G/H
Type
Art. No.
2.5
Hex
DAB 75 259 HL
2.5
Non-hex
DAB 75 259 NL
Hex
DAB 75 359 HL
Non-hex
DAB 75 359 NL
3.5
3.5
7.5
Hex
Non-hex
3.5
3.5
2.5
2.5
7.5
Hex
Non-hex
Note: 1) If the Implantium fixture with size of 3.4 body is used, abutment height after assembly will become 0.5mm longer
than other sized fixtures.
2) It is recommended to keep the torque level at 25~30 Ncm to tighten the dual milling abutment with fixture.
30
5.5
12
G/H 1.5
Diameter 4.0
4.0
4.0
G/H
Type
Art. No.
1.0
Hex
DAB 40 105 HG
1.0
Non-hex
DAB 40 105 NG
1.0
Diameter 4.5
G/H
Type
Art. No.
1.5
Hex
DAB 45 156 HG
1.5
Non-hex
DAB 45 156 NG
1.0
Hex
Non-hex
4.5
4.5
1.5
1.5
Hex
Non-hex
5.5
5.5
Diameter 5.5
G/H
Type
Art. No.
1.5
Hex
DAB 55 157 HG
1.5
Non-hex
DAB 55 157 NG
Hex
DAB 55 257 HG
Non-hex
DAB 55 257 NG
2.5
2.5
5.5
1.5
Hex
2.5
2.5
1.5
Non-hex
5.5
Hex
Non-hex
Note: 1) If the Implantium fixture with size of 3.4 body is used, abutment height after assembly will become 0.5mm longer
than other sized fixtures.
2) It is recommended to keep the torque level at 25~30 Ncm to tighten the dual milling abutment with fixture.
31
Diameter 6.5
G/H
Type
1.5
Hex
DAB 65 158 HG
1.5
Non-hex
DAB 65 158 NG
Hex
DAB 65 258 HG
Non-hex
DAB 65 258 NG
Hex
DAB 65 358 HG
Non-hex
DAB 65 358 NG
2.5
3.5
3.5
6.5
6.5
Art. No.
2.5
6.5
6.5
1.5
Hex
Non-hex
2.5
2.5
1.5
Hex
Non-hex
6.5
6.5
3.5
3.5
Hex
Non-hex
Diameter 7.5
G/H
Type
2.5
Hex
DAB 75 259 HG
2.5
Non-hex
DAB 75 259 NG
Hex
DAB 75 359 HG
Non-hex
DAB 75 359 NG
3.5
3.5
Art. No.
Non-hex
7.5
3.5
3.5
2.5
2.5
Hex
7.5
7.5
7.5
Hex
Non-hex
Note: 1) If the Implantium fixture with size of 3.4 body is used, abutment height after assembly will become 0.5mm longer
than other sized fixtures.
2) It is recommended to keep the torque level at 25~30 Ncm to tighten the dual milling abutment with fixture.
32
4.5
15
10.5
G/H 1.5
Diameter 4.5
| Angled 15
G/H
Type
Art. No.
1.5
Hex
AAB 15 45 15 HL
1.5
Non-hex
AAB 15 45 15 NL
2.5
Hex
AAB 15 45 25 HL
2.5
Non-hex
AAB 15 45 25 NL
3.5
Hex
AAB 15 45 35 HL
3.5
Non-hex
AAB 15 45 35 NL
Diameter 5.5
G/H
4.5
4.5
Hex
2.5
1.5
1.5
4.5
4.5
Non-hex
Hex
4.5
4.5
3.5
2.5
Hex
Non-hex
3.5
Non-hex
| Angled 15
Type
Art. No.
1.5
Hex
AAB 15 55 15 HL
1.5
Non-hex
AAB 15 55 15 NL
2.5
Hex
AAB 15 55 25 HL
2.5
Non-hex
AAB 15 55 25 NL
3.5
Hex
AAB 15 55 35 HL
3.5
Non-hex
AAB 15 55 35 NL
5.5
5.5
Non-hex
5.5
2.5
1.5
1.5
Hex
5.5
Hex
Non-hex
5.5
5.5
3.5
2.5
Hex
3.5
Non-hex
Note: 1) If the Implantium fixture with size of 3.4 body is used, abutment height after assembly will become 0.5mm longer
than other sized fixtures.
2) It is recommended to keep the torque level at 25~30 Ncm to tighten the angled abutment with fixture.
33
4.5
25
10.5
G/H 1.5
Diameter 4.5
| Angled 25
G/H
Type
Art. No.
1.5
Hex
AAB 25 45 15 HL
1.5
Non-hex
AAB 25 45 15 NL
2.5
Hex
AAB 25 45 25 HL
2.5
Non-hex
AAB 25 45 25 NL
3.5
Hex
AAB 25 45 35 HL
3.5
Non-hex
AAB 25 45 35 NL
Diameter 5.5
G/H
4.5
4.5
Non-hex
4.5
2.5
1.5
1.5
Hex
4.5
Hex
4.5
3.5
2.5
Non-hex
4.5
Hex
3.5
Non-hex
| Angled 25
Type
Art. No.
1.5
Hex
AAB 25 55 15 HL
1.5
Non-hex
AAB 25 55 15 NL
2.5
Hex
AAB 25 55 25 HL
2.5
Non-hex
AAB 25 55 25 NL
3.5
Hex
AAB 25 55 35 HL
3.5
Non-hex
AAB 25 55 35 NL
5.5
5.5
Non-hex
5.5
2.5
1.5
1.5
Hex
5.5
Hex
Non-hex
5.5
5.5
3.5
2.5
Hex
3.5
Non-hex
Note: 1) If the Implantium fixture with size of 3.4 body is used, abutment height after assembly will become 0.5mm longer
than other sized fixtures.
2) It is recommended to keep the torque level at 25~30 Ncm to tighten the angled abutment with fixture.
34
4.5
15
10.5
G/H 1.5
Diameter 4.5
| Angled 15
G/H
Type
Art. No.
1.5
Hex
AAB 15 45 15 HG
1.5
Non-hex
AAB 15 45 15 NG
2.5
Hex
AAB 15 45 25 HG
2.5
Non-hex
AAB 15 45 25 NG
3.5
Hex
AAB 15 45 35 HG
3.5
Non-hex
AAB 15 45 35 NG
Diameter 5.5
G/H
4.5
4.5
Non-hex
4.5
2.5
1.5
1.5
Hex
4.5
Hex
4.5
3.5
2.5
Non-hex
4.5
Hex
3.5
Non-hex
| Angled 15
Type
Art. No.
1.5
Hex
AAB 15 55 15 HG
1.5
Non-hex
AAB 15 55 15 NG
2.5
Hex
AAB 15 55 25 HG
2.5
Non-hex
AAB 15 55 25 NG
3.5
Hex
AAB 15 55 35 HG
3.5
Non-hex
AAB 15 55 35 NG
5.5
5.5
Non-hex
5.5
2.5
1.5
1.5
Hex
5.5
Hex
Non-hex
5.5
5.5
3.5
2.5
Hex
3.5
Non-hex
Note: 1) If the Implantium fixture with size of 3.4 body is used, abutment height after assembly will become 0.5mm longer
than other sized fixtures.
2) It is recommended to keep the torque level at 25~30 Ncm to tighten the angled abutment with fixture.
35
4.5
25
10.5
G/H 1.5
Diameter 4.5
| Angled 25
G/H
Type
Art. No.
1.5
Hex
AAB 25 45 15 HG
1.5
Non-hex
AAB 25 45 15 NG
2.5
Hex
AAB 25 45 25 HG
2.5
Non-hex
AAB 25 45 25 NG
3.5
Hex
AAB 25 45 35 HG
3.5
Non-hex
AAB 25 45 35 NG
Diameter 5.5
G/H
4.5
4.5
Non-hex
4.5
2.5
1.5
1.5
Hex
4.5
Hex
4.5
3.5
2.5
Non-hex
4.5
Hex
3.5
Non-hex
| Angled 25
Type
Art. No.
1.5
Hex
AAB 25 55 15 HG
1.5
Non-hex
AAB 25 55 15 NG
2.5
Hex
AAB 25 55 25 HG
2.5
Non-hex
AAB 25 55 25 NG
3.5
Hex
AAB 25 55 35 HG
3.5
Non-hex
AAB 25 55 35 NG
5.5
5.5
Non-hex
5.5
2.5
1.5
1.5
Hex
5.5
Hex
Non-hex
5.5
5.5
3.5
2.5
Hex
3.5
Non-hex
Note: 1) If the Implantium fixture with size of 3.4 body is used, abutment height after assembly will become 0.5mm longer
than other sized fixtures.
2) It is recommended to keep the torque level at 25~30 Ncm to tighten the angled abutment with fixture.
36
4.5
4.5
12
12
4.5
G/H 1.0
4.5
G/H
Type
Art. No.
1.0
Hex
RAB 45 GH
1.0
Non-hex
RAB 45 GN
G/H 1.0
4.5
12
12
4.5
G/H
Type
Art. No.
1.0
Hex
RAB 45 CH
1.0
Non-hex
RAB 45 CN
4.5
4.5
1.0
1.0
Hex
Non-hex
4.5
4.5
12
12
4.5
1.0
Hex
4.5
1.0
Non-hex
Note: 1) If the Implantium fixture with size of 3.4 body is used, abutment height after assembly will become 0.5mm longer than other
sized fixtures.
2) It is recommended to keep the torque level at 25~30 Ncm to tighten the direct-casting / metal-casing abutment with fixture.
37
Temporary Abutment
Abutment screw is included.
4.5
4.5
10
8
G/H 2.0
G/H 1.0
Ti-Temporary Abutment
Diameter
G/H
Type
4.5
4.5
Art. No.
10
10
1.0
Hex
1.0
Non-hex
G/H
Type
4.5
Art. No.
4.5
8.0
5.5
8.0
2.0
5.5
2.0
hex
Non-hex
6.5
6.5
hex
Non-hex
8.0
2.0
hex
Non-hex
Note: 1) If the Implantium fixture with size of 3.4 body is used, abutment height after assembly will become 0.5mm longer
than other sized fixtures.
2) It is recommended to keep the torque level at 25~30 Ncm to tighten the temporary abutment with fixture.
38
Prosthetic Procedure 3
Impression Technique and Restoration Selection
Screw Abutment
Abutment Level Impression
Screw Abutment
Page 39
Page 40
4.5 / 5.5
4.5 / 5.5
Page 41
Page 41
Analog
4.5/5.5
Page 42
Burn-out Cylinder
Gold Cylinder
4.5 / 5.5
4.5 / 5.5
Metal Cylinder
Titanium Cylinder
Page 43
Page 43
Page 43
Page 43
4.5 / 5.5
Bridge
(Non-hex)
Single
(Hex)
Bridge
(Non-hex)
Single
(Hex)
Bridge
(Non-hex)
Single
(Hex)
Polishing Protector
4.5 / 5.5
Bridge
(Non-hex)
Single
(Hex)
Temporary Restoration
4.5 / 5.5
Page 42
Ti-Retaining Screw
Page 42
Screw-Retained Restoration
39
Screw Abutment
Unit: mm, Scale 1 : 1.5 / mm
5.5
G/H 3.5
Delivery Holder
Diameter 4.5
G/H
Art. No.
1.0 SAB45 10 L
1.5 SAB45 15 L
2.5 SAB45 25 L
3.5 SAB45 35 L
4.5 SAB45 45 L
5.5 SAB45 55 L
G/H
1.0
1.5
2.5
3.5
4.5
5.5
G/H
Diameter 5.5
G/H
Art. No.
1.5 SAB55 15 L
2.5 SAB55 25 L
3.5 SAB55 35 L
4.5 SAB55 45 L
5.5 SAB55 55 L
G/H
1.5
2.5
3.5
4.5
5.5
G/H
Note: 1) The Implantium fixture with size of 3.4 body is not recommended to use with the screw abutment. Should they be
used together, abutment height after assembly will become 0.5mm longer than the other sized fixtures.
2) It is recommended to keep the torque level at 25~30 Ncm to tighten the screw abutment with fixture.
40
5.5
5.5
30
15
G/H 1.5
G/H 1.5
Delivery Holder
G/H
Type
Art. No.
1.0
Hex
ASA 45 15 10 18 H
1.0
Non-hex
ASA 45 15 10 18 N
Hex
ASA 45 30 10 18 H
1.0
1.0
Non-hex
ASA 45 30 10 18 N
2.0
Hex
ASA 45 15 20 18 H
2.0
Non-hex
ASA 45 15 20 18 N
Hex
ASA 45 30 20 18 H
Non-hex
ASA 45 30 20 18 N
2.0
2.0
15
15
30
30
1.0
1.0
1.0
1.0
2.0
2.0
2.0
2.0
Hex
Non-hex
Hex
Non-hex
15
15
30
30
G/H
Type
Art. No.
1.5
Hex
ASA 55 15 15 18 H
1.5
Non-hex
ASA 55 15 15 18 N
Hex
ASA 55 30 15 18 H
1.5
Non-hex
ASA 55 30 15 18 N
3.0
Hex
ASA 55 15 30 18 H
3.0
Non-hex
ASA 55 15 30 18 N
Hex
ASA 55 30 30 18 H
Non-hex
ASA 55 30 30 18 N
1.5
3.0
3.0
Hex
1.5
1.5
1.5
1.5
3.0
3.0
3.0
3.0
Non-hex
Hex
Non-hex
2.3
7.3
ASASC 20 23
2.0
Note: 1) The Implantium fixture with size of 3.4 body is not recommended to use with the screw abutment. Should they be
used together, abutment height after assembly will become 0.5mm longer than the other sized fixtures.
2) It is recommended to keep the torque level at 25~30 Ncm to tighten the screw abutment with fixture.
41
Type
4.5
4.5
5.5
5.5
4.5
Single (Hex)
Bridge (Non-hex)
5.5
5.5
Single (Hex)
Bridge (Non-hex)
4.5
4.5
Single (Hex)
Bridge (Non-hex)
5.5
5.5
Single (Hex)
Bridge (Non-hex)
Art. No.
Diameter
4.5
Art. No.
4.5
4.5
5.5
5.5
Type
Art. No.
Pick-up
SPS 09
Transfer
STS 09
15.0
9.0
42
Comfort Cap
Diameter
4.5
Art. No.
4.5 SCC 45 L
5.5 SCC 55 L
5.0
Analog
5.5
5.0
4.5
Diameter
5.5
Art. No.
4.5 SAN 45 L
5.5 SAN 55 L
12.0
12.0
Polishing Protector
Diameter
Art. No.
4.5 SPP 45 L
5.5 SPP 55 L
4.5
Ti-Retaining Screw
5.5
2.3
SRS 18 T
1.8
Ti-Cylinder
Diameter
4.5
4.5
Type
Art. No.
4.5
4.5
5.5
5.5
8.7
8.7
3.3
3.3
Single (Hex)
Bridge (Non-hex)
5.5
5.5
Single (Hex)
8.7
8.7
3.3
3.3
Bridge (Non-hex)
2.3
1.8
2.3
1.8
43
Gold Cylinder
Diameter
4.5
Type
4.5
Art. No.
4.5
4.5
5.5
5.5
2.3
12.0
Single (Hex)
12.0
Bridge (Non-hex)
5.5
5.5
12.0
Single (Hex)
Type
4.5
12.0
Bridge (Non-hex)
4.5
4.5
5.5
5.5
Single (Hex)
12.0
Bridge (Non-hex)
Type
12.0
Single (Hex)
Bridge (Non-hex)
4.5
4.5
Art. No.
4.5
4.5
5.5
5.5
1.8
5.5
12.0
Diameter
1.8
2.3
12.0
5.5
Burn-out Cylinder
2.3
4.5
Art. No.
1.8
2.3
1.8
2.3
12.0
12.0
Single (Hex)
Bridge (Non-hex)
5.5
5.5
1.8
2.3
12.0
Single (Hex)
12.0
Bridge (Non-hex)
1.8
44
Prosthetic Procedure 4
Impression Technique and Restoration Type
Overdenture Procedure
Positioner / Mini Ball / Magnetic Attachment
Positioner Abutment
Implant Keeper
Implant Keeper
3.5
3.5
4.5 / 5.5
4.5 / 5.5
Page 45
Page 47
Page 48
Page 49
Magnetic Assay
Magnetic Assay
Page 48
Page 49
Page 45
Page 47
Positioner Analog
Page 45
Page 47
Socket Spacer
Page 46
Page 47
Page 46
Positioner Attachment
for Overdenture
Magnetic Attachment
for Overdenture
45
Positioner
Unit: mm, Scale 1 : 1.5 / mm
5.2
2.3
0.4
G/H 2.0
Positioner Abutment
G/H
Art. No.
1.0
PAB 35 10
2.0
PAB 35 20
3.0
PAB 35 30
4.0
PAB 35 40
5.0
PAB 35 50
6.0
PAB 35 60
7.0
PAB 35 70
3.5
3.5
G/H
1.0
3.5
2.0
3.5
3.5
5.0
4.0
3.0
3.5
3.5
6.0
4.5
4.5
Positioner Analog
PAN
12.4
Note: 1) The Implantium fixture with size of 3.4 body is not recommended to use with the positioner abutment. Should they
be used together, abutment height after assembly will become 0.5mm longer than the other sized fixtures.
2) It is recommended to keep the torque level at 25~30 Ncm to tighten the ball abutment with fixture.
7.0
46
Positioner
Unit: mm, Scale 1 : 1.5 / mm
Plastic Socket
5.2
FSMH
2.3
Art. No.
MSHP (Blue)
Tilting Type
10
MSMP (Orange)
MSLP (Ivory)
Retention Force
100gf
300gf
500gf
1,000gf
Retention Force
100gf
300gf
500gf
1,000gf
MSOP (White)
MSHPN (Blue)
MSMPN (Orange)
MSLPN (Ivory)
MSOP
(White)
PBOS
XPCT
6.5
0.5
47
4.05
2.9
G/H 2.0
G/H
Art. No.
BAB 35 0018
1.0
BAB 35 1018
2.0
BAB 35 2018
3.0
BAB 35 3018
4.0
BAB 35 4018
5.0
BAB 35 5018
3.3
3.5
3.5
3.5
3.5
3.5
1.8
1.8
1.8
1.8
1.8
1.8
1.0
2.0
3.0
4.0
5.0
4.0
GICA
Socket Spacer
GBIC3L
Art. No.
GBIC2L
Female Socket
BPF3 (300~500gf)
Art. No.
BPF2 (500~700gf)
4.05
(BFS3)
4.85
2.9
3.3
(BNO1)
(300~500gf)
(BFS2)
(BNO2)
(500~700gf)
Note: 1) The Implantium fixture with size of 3.4 body is not recommended to use with the ball abutment. Should they be used
together, abutment height after assembly will become 0.5mm longer than the other sized fixtures.
2) It is recommended to keep the torque level at 25~30 Ncm to tighten the ball abutment with fixture.
48
4.5
2.0
0.5
G/H 2.0
Magnetic Assay
Application
Diameter
Art. No.
MKP45D
4.5
2.0
MGT 45 20 D
MKP55D
5.5
2.0
MGT 55 20 D
4.5
2.0
2.5
5.5
2.0
2.5
G/H
Art. No.
1.0
MKP 45 10 D
2.0
MKP 45 20 D
3.0
MKP 45 30 D
4.0
MKP 45 40 D
5.0
MKP 45 50 D
6.0
MKP 45 60 D
G/H
1.0
2.0
3.0
4.0
5.0
6.0
G/H
G/H
Art. No.
1.0
MKP 55 10 D
2.0
MKP 55 20 D
3.0
MKP 55 30 D
4.0
MKP 55 40 D
5.0
MKP 55 50 D
6.0
MKP 55 60 D
G/H
1.0
2.0
3.0
4.0
5.0
6.0
G/H
Note: 1) The Implantium fixture with size of 3.4 body is not recommended to use with the magnetic abutment. Should they be
used together, abutment height after assembly will become 0.5mm longer than the other sized fixtures.
2) It is recommended to keep the torque level at 25~30 Ncm to tighten the magnetic abutment with fixture.
49
4.5
1.5
G/H 2.0
Magnetic Assay
4.5
Application
Diameter
Art. No.
MKP45
4.5
1.5
MGT 45 15
MKP45
4.5
2.0
MGT 45 20
MKP55
5.5
1.5
MGT 55 15
MKP55
5.5
2.0
MGT 55 20
1.5
4.5
2.0
5.5
1.5
5.5
2.0
G/H
1.0
Art. No.
MKP 45 10
2.0
MKP 45 20
3.0
MKP 45 30
4.0
MKP 45 40
5.0
MKP 45 50
6.0
MKP 45 60
G/H
1.0
2.0
3.0
4.0
5.0
6.0
G/H
G/H
Art. No.
1.0
MKP 55 10
2.0
MKP 55 20
3.0
MKP 55 30
4.0
MKP 55 40
5.0
MKP 55 50
6.0
MKP 55 60
G/H
1.0
2.0
3.0
4.0
5.0
6.0
G/H
Note: 1) The Implantium fixture with size of 3.4 body is not recommended to use with the magnetic abutment. Should they be
used together, abutment height after assembly will become 0.5mm longer than the other sized fixtures.
2) It is recommended to keep the torque level at 25~30 Ncm to tighten the magnetic abutment with fixture.
50
UXIF
Kit Contents
First guide drill
XLD 22 29
Parallel pin x4
XPP 162220 T
Hand-piece adapter
XID 27 H
XLD 22 35 (Stopper)
XLD 26 29
XLD 26 35 (Stopper)
XID 32 H
XFD 34 35
XFD 38 35
Ratchet adapter
XID 26 W
XFD 43 35
XID 32 W
XFD 48 35
Final drill
XFD 34 29
XFD 38 29
XFD 43 29
Path pin x2
XMFPA2
Hex driver
XHD 26 T
Drill extension
XDE
XFD 48 29
XFD 58 31
Countersink
XCS 36 29 SW
XCS 40 29 SW
Depth gauge
XDGL
XCS 45 29 SW
XCS 50 29 SW
XCS 60 29 SW
XCS 70 29 SW
Ratchet
XRCA1
51
UXIFN
Kit Contents
Final drill
XLD 22 31
Parallel pin
XPP 162220 T
XPP 162226 T
XLD 26 31
Hand-piece adapter
XID 30 H
Ratchet adapter
XID 26 W
MF path pin x2
XMFPA2
Hex driver
XHD 26 T
XFD 34 31
XFD 38 31
XFD 43 31
XFD 48 31
XFD 58 31
Countersink
XHD 25 H
XCS 36 29 SW
XCS 40 29 SW
Drill extension
XDE
XCS 45 29 SW
XCS 50 29 SW
XCS 60 29 SW
XCS 70 29 SW
Ratchet
XRCA1
52
XSIK
Kit Contents
First guide drill
XLD 22 07
Parallel pin 2
XLD 26 07
Hand-piece adapter
XID 27 H
Ratchet adapter
XID 26 W
Final drill
XFC 36 07
MF path pin x2
XMFPA2
Hex driver
XHD 26 T
XFC 40 07
XFC 45 07
XPP 162212
XFC 50 07
XHD 25 H
XFC 60 07
XFC 70 07
Ratchet
XRCA1
53
XDS
Kit Contents
XLDST 12
XLDST 10
XLDST 08
XLDST 06
XFDST 08
XFDST 06
XFDST 08L
XFDST 06L
XLD 26 35
XFDST 14
XFDST 12
XFDST 10
XFD 38 35
XFD 48 35
XFDST 14L
XFDST 12L
XFDST 10L
54
Drill
8 10 12 14 16
Guide Drill
Diameter
1.5
20
XGD 15 20
1.5
28
XGD 15 28
1.5
Art. No.
20
1.5
28
First Drill
Diameter
2.0
29
XFD 20 29
2.0
33
XFD 20 33
2.0
Art. No.
29
2.0
33
2.2
26
1.7
2.2
1.7
Art. No.
2.2
26
XLD 22 07
2.2
29
XLD 22 29
2.2
31
XLD 22 31
2.2
33
XLD 22 33
2.2
35
XLD 22 35
2.2
41
XLD 22 41
29
2.2
1.7
31
2.2
1.7
33
2.2
Stopper
1.7
35
2.2
1.7
41
2.6
2.35
26
2.6
26
XLD 26 07
2.6
29
XLD 26 29
2.6
31
XLD 26 31
2.6
33
XLD 26 33
2.6
35
XLD 26 35
2.6
41
XLD 26 41
2.6
Art. No.
2.35
29
2.6
2.35
31
2.6
2.35
33
2.6
2.35
Stopper
35
2.6
2.35
41
Note: Drill speed 1,000rpm, 30~45Ncm with irrigation.
55
Drill
Unit: mm, Scale 1 : 1 / mm
Pilot Drill
Diameter
30
3.0
Art. No.
XPD 20 30
3.0
1.9
30
7.0
Art. No.
3.6
27 XFC 36 07
4.0
27
XFC 40 07
4.5
27
XFC 45 07
5.0
27
XFC 50 07
6.0
27
XFC 60 07
7.0
27
XFC 70 07
3.6
2.85
4.0
3.3
4.5
3.85
5.0
4.4
6.0
4.4
7.0
5.4
27
12
Art. No.
2.9
29 XFD 34 29
3.35
29
XFD 38 29
3.85
29
XFD 43 29
4.4
29
XFD 48 29
5.4
29
XFD 58 29SW
2.9
3.35
3.85
4.4
5.4
29
14
Art. No.
2.9
31 XFD 34 31
3.35
31
XFD 38 31
3.85
31
XFD 43 31
4.4
31
XFD 48 31
5.4
31
XFD 58 31
2.9
3.35
3.85
4.4
5.4
31
56
Drill
Unit: mm, Scale 1 : 1 / mm
16
Art. No.
2.9
33 XFD 34 33
3.35
33
XFD 38 33
3.85
33
XFD 43 33
4.4
33
XFD 48 33
2.9
3.35
3.85
4.4
33
Art. No.
2.9
35 XFD 34 35
3.35
35
XFD 38 35
3.85
35
XFD 43 35
4.4
35
XFD 48 35
2.9
3.35
3.85
4.4
35
16
Art. No.
2.9
41 XFD 34 41
3.35
41
XFD 38 41
3.85
41
XFD 43 41
4.4
41
XFD 48 41
2.9
3.35
3.85
4.4
41
57
Drill
Unit: mm, Scale 1 : 1 / mm
Art. No.
2.85
35 XFH 34 35
3.3
35
XFH 38 35
3.85
35
XFH 43 35
4.4
35
XFH 48 35
2.85
3.3
3.85
4.4
35
Countersink
Diameter
Art. No.
3.6
29 XCS 36 29 SW
4.0
29
XCS 40 29 SW
4.5
29
XCS 45 29 SW
5.0
29
XCS 50 29 SW
6.0
27
XCS 60 29 SW
7.0
27
XCS 70 29 SW
3.6
4.0
4.5
5.0
29
6.0
7.0
27
Round Bur
Diameter
Art. No.
2.0
33 XRB 20 33
3.0
33
XRB 30 33
2.0
3.0
58
Stopper
Unit: mm, Scale 1 : 1 / mm
Drilling Depth
14
Art. No.
4.6 XLDST 14
4.45
12 6.6 XLDST 12
10 8.6 XLDST 10
4.45
4.6
XLDST14
4.45
6.6
XLDST12
08 10.6 XLDST 08
4.45
8.6
XLDST10
4.45
12.6
10.6
XLDST08
06 12.6 XLDST 06
4.45
XLDST06
4.45
14.6
16.6
XLDST04
XLDST02
5.14
5.14
04 14.6 XLDST 04
02 16.6 XLDST 02
Drilling Depth
14
Art. No.
4.6 XFDST 14
5.14
4.6
12 6.6 XFDST 12
10 8.6 XFDST 10
5.14
XFDST14
5.14
6.6
XFDST12
08 10.6 XFDST 08
5.14
8.6
XFDST10
5.14
12.6
10.6
XFDST08
06 12.6 XFDST 06
XFDST06
14.6
XFDST04
16.6
XFDST02
04 14.6 XFDST 04
02 16.6 XFDST 02
Drilling Depth
14
Art. No.
6.14
4.6
6.14
XFDST14L
6.14
6.6
XFDST12L
6.14
8.6
XFDST10L
6.14
10.6
XFDST08L
6.14
12.6
XFDST06L
6.14
14.6
XFDST04L
16.6
XFDST02L
59
Instrument
Unit: mm, Scale 1 : 1 / mm
Type
Art. No.
27 XID 27 H
Hand-piece
30
32 XID 32 H
24
XID 24 W
Ratchet
26
XID 26 W
29
XID 29 W
29
XID 32 W
27
XID 30 H
30
32
24
26
29
32
Diameter
Art. No.
1.6
XPP 162212
1.6
XPP 162220T
1.6
XPP 162226T
1.6
15.5
1.6
20
1.6
26
Path Pin
Art. No.
18.6
XMFPA2
18.6
60
Instrument
Unit: mm, Scale 1 : 1 / mm
Type
Art. No.
Hand-piece
25
XHD 25 H
21
XHD 21 W
25
XHD 25 W
27
XHD 27 W
Manual
26
XHD 26 T
Ratchet
30
25
21
25
XHD 30 T
27
26
30
Slot Driver
Type
Art. No.
Ratchet
SDA 17 R
SDA 25 R
17
25
Drill Extension
XDE
26
Driver | Manual
Type
12
Art. No.
Manual XHDHT
61
Instrument
Unit: mm
Type
Hand-piece
Ratchet
Art. No.
XMAA1
XMA 21W
20
21
21
Ratchet
XRCA1
Depth Gauge
XDGL
Note: One side of Depth Gauge measures the
osteotomy depth and the other side
measures the gingival height from the
top of the implant.
62
DASK
Kit Contents
DASK drill
XRT332035
XRT372035
Stopper
XFDST 08
XED331035D
XRT064025
XRT084025
XST083025
XSE1L
XSE2L
XSE3L
XSE4L
XFDST 06
XFDST 04
XFDST 02
63
XRT083025
SDK
Kit Contents
DASK drill
Stopper
XFDST 08
XFDST 06
XRT332035
XRT064025
XRT372035
XRT084025
XED331035D
XST083025
XFDST 04
XFDST 02
Sinus Kit
(XSE1L)
(XSE2L)
(XSE3L)
(XSE4L)
XSKL
64
XRT332035
Lateral
Approach
DASK Drill #
Art.No.
DASK Drill #1
XRT 332035
DASK Drill #2
XRT 372035
DASK Drill #3
XED 331035D
DASK Drill #4
XRT 064025
DASK Drill #5
XRT 084025
DASK Drill #6
XST 083025
3.3
12 10 8
12 10 8
XRT372035
3.7
XED331035D
1.6
12 10 8
210
6.0
XRT064025
4.0
XRT084025
8.0
4.0
XST083025
6.6
8.0
1.51.5
Drilling Depth
08
Art.No.
10.6 XFDST 08
5.14
10.6
06 12.6 XFDST 06
04 14.6 XFDST 04
02 16.6 XFDST 02
XSE1L
XSE2L
XSE3L
XSE4L
5.14
XFDST08
5.14
12.6
XFDST06
5.14
14.6
XFDST04
16.6
XFDST02
3.3
65
Osteotome Kit
Unit: mm
Osteotome Kit
Osteotome compresses the bone laterally, providing denser bony interface
rather than removing valuable bone from the surgical site.
XOF 20 A1
XOF 20 B1
Type A
(Convex)
XOF 34 A1
XOF 34 B1
XOF 38 A1
XOF 38 B1
Type B
(Concave)
XOF 43 A1
XOF 43 B1
XOF 48 A1
XOF 48 B1
Osteotome Kit
Type
Art.No. A B
XOFK
Type A
XOF 34 A1 2.3
(Convex)
2.8
XOFBK
Type B
XOF 34 B1 2.3
(Concave)
2.8
XOFK (Type A)
XOFBK (Type B)
66
Trephine Kit
Unit: mm
Trephine Bur
Excellent fine cutting
Strong engagement when attaching the trephine to cortical bone
Cut-outs facilitates ease of harvest retrieval
23
37
14
Easy harvesting
Inner
Diameter
Art. No.
3.0
2.3
XTP 24 03
4.0
3.3
XTP 34 04
5.0
4.2
XTP 44 05
6.0
5.2
XTP 54 06
7.0
6.1
XTP 64 07
8.0
7.1
XTP 74 08
9.0
8.0
XTP 84 09
10.0
9.0
XTP 94 10
4.0
3.0
Outer
Outer
3.3
2.3
Inner
Inner
6.0
5.0
Outer
Outer
5.2
4.2
Inner
Inner
8.0
7.0
Outer
Outer
7.1
6.1
Inner
Inner
10.0
9.0
Outer
Outer
9.0
8.0
Inner
Trephine Kit
XIT
10
8
6
4
2
Inner
Prosthetic Kit
Hex Driver S/T | Scale 1 : 1 / mm
B.WRENCH
ADAPTER
XHD 15
XIP
67
68
Planning Kit
Unit: mm, Scale 1 : 1 / mm
Kit Contents
Diameter 4.5 | Combi & Dual abutment
G/H
Art.No.
1.5
PDAB 45 15
2.5
PDAB 45 25
3.5
PDAB 45 35
4.5
PDAB 45 45
5.5
PDAB 45 55
XPK
G/H
5.5
4.5
3.5
2.5
1.5
G/H
Art.No.
G/H
Art.No.
1.5
PDAB 55 15
1.5
PDAB 65 15
2.5
PDAB 55 25
2.5
PDAB 65 25
3.5
PDAB 55 35
3.5
PDAB 65 35
4.5
PDAB 55 45
4.5
PDAB 65 45
5.5
PDAB 55 55
5.5
PDAB 65 55
G/H
5.5
4.5
3.5
2.5
1.5
G/H
Art.No.
5.5
4.5
3.5
2.5
1.5
Art.No.
4.5
2.0
PAAB 15 45 20
4.5
2.0
PAAB 25 45 20
4.5
4.0
PAAB 15 45 40
4.5
4.0
PAAB 25 45 40
5.5
2.0
PAAB 15 55 20
5.5
2.0
PAAB 25 55 20
5.5
4.0
PAAB 15 55 40
5.5
4.0
PAAB 25 55 40
G/H
15
2.0
15
4.0
15
2.0
15
4.0
G/H
25
2.0
25
4.0
25
2.0
25
4.0
69
Art. No.
13
XHD 13
15
XHD 15
21
XHD 21
28
XHD 28
13
Hex 1.28
Diameter
Art. No.
4.5 CRG 45 L
5.5 CRG 55 L
6.5 CRG 65 L
4.5
5.5
6.5
Type
Art. No.
Bridge SRG BL
Single SRG SL
Bridge
Single
15
21
28
70
71
Help Kit
Unit: mm
Art. No
25 XRRHD
25
XIH
Art. No
20 XRHR20
25 XRFS2S
25 XRHR25
33 XRFS2
Art. No
33
20
25
25
Type
Art. No
Type
Art. No
XRFRT
Tap
XRSTR
Remover
XRFRTF
11 Guide
XRSG11
XRFRTO
8 Guide
XRSG8
Wrench
XRFRW
8
11
11
25
25
75
25
25
72
SURGICAL MANUAL
Surgical Drill Sequence I
Surgical Drill Sequence II
Drilling Depth Guide
Fixture Connection
Installation Procedure & Warnings
Surgical Kit Maintenance
73
75
77
79
80
81
73
First
Guide Drill
Final Drill
Second
Guide Drill
3.6
2.2
Platform: 4.0
Platform: 4.5
Platform: 5.0
Platform: 6.0
Platform: 7.0
4.5
Countersink
5.0
3.6
4.0
4.5
5.0
6.0
7.0
7.0
3.6
4.0
4.5
5.0
6.0
5.4
7.0
2.6
2.9
Platform: 3.6
4.0
3.35
3.85
4.4
74
Crestal
Bone
-0.5mm
7mm
10mm
Depth Indication
Depth
Gauge
Use the depth gauge after first drill / First guide drill to check depth of drilling.
Place the depth gauge against the wall of the osteotomy.
75
First
Guide Drill
Harvest Drill
Second
Guide Drill
3.4
2.2
3.8
4.3
Final Drill
Countersink
4.8
3.6
4.0
4.5
5.0
6.0
7.0
7.0
3.6
4.0
4.5
5.0
6.0
5.4
7.0
2.6
2.85
3.3
3.85
4.4
Platform: 3.6
Platform: 4.0
Platform: 4.5
Platform: 5.0
Platform: 6.0
Platform: 7.0
: During the 4.3/4.8 fixture insertion into the bone density of D3~D4, the 3.4/3.8 harvest drilling process can be skipped.
76
Harvest Drill
Simultaneous and effective autogenous bone collection during the final drilling procedure using a
specially designed drill
S harp pointed tip design of the drill prevents drill chatter and helps guide drill path.
A
vailable drill stopper helps control drill depth for safe and efficient bone collection, especially in the buccal side
of ridge.
Recommended drill speed of less than 100rpm/50Ncm helps preserve the vital autogenous bone.
Excellent clinical results may be achieved when harvested autogenous bone is combined with OSTEON II.
Harvest drill
4.0
Stopper
Locking with drill stopper for bone collection
(I)
( II )
Second
guide drill
(1000rpm / 30~45Ncm)
Final drill
3.6
Countersink
3.6
FXS 3610
FX 3410
3.7
3.6
3.6
3.4
0.5mm
10mm
Second
guide drill
(1000rpm / 30~45Ncm)
Final drill
3.6
Final drill
4.0
Countersink
4.0
FXS 4010
4.0
FX 3810
4.0
0.5mm
10mm
4.0
Second
guide drill
3.8
(1000rpm / 30~45Ncm)
Final drill
3.6
Final drill
4.0
Final drill
4.5
Countersink
4.5
FXS 4510
FX 4310
4.5
4.5
4.5
4.3
10mm
0.5mm
77
78
Second
guide drill
(1000rpm / 30~45Ncm)
Final drill
3.6
Final drill
4.0
Final drill
4.5
Final drill
5.0
Countersink
5.0
FXS 5010
FX 4810
5.0
5.0
5.0
4.8
0.5mm
10mm
Second
guide drill
(1000rpm / 30~45Ncm)
Final drill
3.6
Final drill
4.0
Final drill
4.5
Final drill
5.0
Countersink
6.0
FXS 6010
6.0
0.5mm
10mm
5.0
Second
guide drill
(1000rpm / 30~45Ncm)
Final drill
3.6
Final drill
4.0
Final drill
4.5
Final drill
5.0
Countersink
6.0
Final drill
7.0
Countersink
7.0
FXS 7010
7.0
10mm
5.8
0.5mm
79
Fixture Connection
Caution_ W
hen opening the fixture pack,
hold the fixture container upward
and engage the adapter into the
fixture.
By hand-piece
20rpm / 35Ncm
By ratchet
Connection
Hand-piece
Adapter
Ratchet
Adapter
80
By Hex Driver
Healing Abutment
By Hex Driver
Warnings
Dental Implant surgery and restoration involve complex dental procedures. Appropriate and adequate training in proper
technique is strongly recommended prior to use.
Improper medical examination and/or treatment plan can result in implant failure and/or loss of supportive bone.
Improper initial stability and/or excessive occlusal forces during healing period may lead to osseointergration failure.
Excessive insertion torque may lead to mechanical failure or implant biologic failure due to bone compression and necrosis.
When forces or loads are greater than its design, implant or abutment fracture could happen. Therefore clinicians should
make careful decisions with regards to clinical treatment planning to minimize the risk of fracture. Appropriate implant
quantity, occlusal interface and a nightguard are essential. Potential excessive loading conditions may include the following:
01
02
03
04
05
06
07
08
09
10
11
81
device.
It is important to use and follow proper cleaning, disinfection and sterilization procedures.
It is also important to follow the manufactures recommendation on the usage of drills.
Please keep a log as to how many times the drills are used.
Drills are used per implant placed not per patient. Bone density determines the life of the drills.
Replace white and red o-rings on adapters and hex drivers, if worn and dried out.
Drills should be considered for replacement around 20 uses based on bone density.
01 A
ll instruments immediately after use must be pre-soaked for a few minutes in a germicidal bath to loosen and
prevent debris from attaching to instruments. Do not soak over-night.
02 Scrub with a soft brush to remove any debris.
03 For internal irrigation drills use a reamer or small gauge needle to cleanout drill internally.
04 If using an ultrasonic cleaner, wrap drills in a 2 2 to prevent rubbing against each other.
05 Rinse thoroughly under warm water.
06 Clean all instrument trays with a germicidal cleaner prior to replacing instruments in kit.
07 Dry completely and place back into kit.
08 Always check for damage or corrosion after rinsing and drying.
09 Seal the tray in a sterilization pouch.
10 Sterilize using a steam autoclave at 121C / 250 for 30 minutes or refer to manufacture's recommendations.
11 Store in a dry area at room temperature.
Final Drill
Countersink Drill
Depending on bone density,
the rpm could be adjusted.
82
PROSTHESIS
MANUAL
Prosthetic Introduction
Understanding the Implant and Prosthesis
Types of Abutment
Dual Abutment
Combi Abutment
Dual Milling / Anged / Temporay /
Direct-Casting / Metal-Casting Abutment
Screw Abutment / Angled Screw Abutment
Points to Consider in Abutment Selection
Minimum Height Requirement for
SuperLine Prosthetic Abutment
83
84
85
86
Prosthetic Procedure 1
92
93
96
Prosthetic Procedure 2
Fixture Level [Pick-up Type]- Dual Abutment
Fixture Level [Transfer Type]- Dual Abutment
Fixture Level [Transfer Type]- Dual Milling Abutment
Fixture Level [Pick-up Type]- Angled Abutment
Fixture Level- Direct-Casting Abutment
Fixture Level- Metal-Casting Abutment
Fixture Level [Pick-up Type]- Temporary Abutment
Prosthetic Procedure 3
87
89
90
91
98
99
102
105
107
109
110
111
112
113
116
Prosthetic Procedure 4
118
Positioner 119
Ball Attachment
121
Magnetic Attachment
122
Biological Connection
The tapered conical hex connection between implant
and abutment interface provides hermetic sealing.
The biological connection distributes the load to the
fixture evenly. Therefore it may minimize bone loss.
All implant diameters share the same internal connection.
One abutment screw fits all abutments and fixtures.
Types of Abutment (Abutments are available in various diameters & gingival heights)
Dual Abutment
Combi Abutment
Abutment level
Dual Abutment
Dual Milling Abutment
Angled Abutment (15/25)
Direct-Casting Abutment
Fixture level
Metal-Casting Abutment
Temporary Abutment (Plastic & Titanium)
Screw Abutment
Angled Screw Abutment (15/ 30)
Positioner Attachment
Ball Attachment
Magnetic Attachment
83
84
Types of Abutment
One-Piece
Two-Pieces
Hex
Combi Abutment
(15)
Hex
Non-hex
Dual Abutment
(30)
(15)
Non-hex
Hex
Non-hex
Hex
Non-hex
Screw Abutment
Hex
Non-hex
Hex
Angled Abutment
Direct-Casting Abutment
Titanium
Hex
Cylinder
Hex
Non-hex
Metal-Casting Abutment
Abutment Level
Non-hex
Non-hex
Plastic
Hex Non-hex
Temporary Abutment
Fixture Level
Selection Guideline
Ideal emergence profile for each tooth
85
Dual Abutment
Hex
Non-hex
Dual Abutment
It is possible to take an impression at both fixture level and abutment level.
(A Dual Abutment may be interchanged with a Combi Abutment)
For abutment level impressions, the same prosthetic procedures apply to both Dual and Combi Abutments.
For fixture level impressions, the abutment selection takes place on the master model.
For fixture level impressions, a precise positioning jig for abutment may be required.
Either hex or non-hex abutments may be used, according to operator's preference.
* If a cement retained restoration requires retrieval, cutting a hole in the occlusal surface would allow access to the
screw to permit removal.
Hex / Non-hex
Positioning Jig
Hex Non-hex
Unnecessary
Radiograph
Required
Required
Unnecessary
Diameter
G/H
Vertical Angle
4.5
5.5
6.5
86
Combi Abutment
Prosthetic part
Transmucosal part
Margin of prosthetic element:
Sub-gingival, equilibrium,
supra-gingival
Diameter
G/H
Vertical Angle
4.5
5.5
6.5
Hex
Hex
Non-hex
Hex
Non-hex
Hex
Non-hex
Temporary Abutment
(15)
Non-hex
Hex
(25)
Non-hex
Angled Abutment
Hex
Non-hex
Direct-Casting Abutment
Hex
Non-hex
Metal-Casting Abutment
Angled Abutment
The Angled Abutment is recommended when the restoration path of
insertion is unfavorable in either anterior or posterior sites.
Retention force can be increased through milling process.
Direct-Casting Abutment
Excellent for either single or bridgework
Used as an esthetic custom made abutment.
Used when angulation is not ideal and a standard abutment cannot be used.
Used when there is inadequate inter-arch distance and a standard abutment cannot be used.
A fixture level impression is taken, and the soft tissue contours can be supported.
87
88
Temporary Abutment
Temporary Abutments are available with titanium or plastic.
The titanium abutment comes in both hex and non-hex with a gingival height of 1.0mm.
The plastic abutment comes in diameters (4.5, 5.5, 6.5) with a gingival height of 2.0mm.
Dual Milling
Hex
Non-hex
1.0mm
4.5
1.5mm
5.5
1.5 / 2.5mm
6.5
7.5
2.5 / 3.5mm
4.5
1.5mm
2.5mm
3.5mm
15 / 25
5.5
1.5mm
2.5mm
3.5mm
15 / 25
4.5
1.0mm
4.5
1.0mm
4.5
1.0mm
4.5
5.5
6.5
2.0mm
Angled
Hex
Direct-Casting
Abutment
Metal-Casting
Abutment
Non-hex
Hex
Hex
Non-hex
Hex
Non-hex
Ti-Temporary
Hex
Plastic
Temporary
Hex
Non-hex
Non-hex
Non-hex
Screw Abutment
Screw Abutment
If prosthesis repair is anticipated, use of a Screw Abutment retained prosthesis enables easy
retrieval.
Useful for connecting multiple units or when there is a preference for a screw retained prosthesis.
Useful when respective long axes of implants differ. Each side tapers by 30 and this permits up to 60
divergence between two abutments.
Useful when the prognosis of an adjacent restoration is not ideal thus permitting easy retrieval and modification
of the restoration.
2.3mm
1.8mm
Screw Abutment
Diameter G/H
4.5
5.5
2.3mm
4.5
1.0mm 15
5.5
1.5mm 30
2.0mm
89
90
Impression of Implant
According to the case the impression can be taken at abutment or fixture level.
Fixture Level
Abutment Level
1. Dual Abutment
1. Dual Abutment
3. Screw Abutment
4. Direct-Casting Abutment
5. Metal-Casting Abutment
6. Temporary Abutment (Plastic & Titanium)
Dual Abutment
Combi Abutment
Cementation type
Angled Abutment
Screw Abutment
Direct-Casting Abutment
Metal-Casting Abutment
3.0
8.0
3.0
8.0
2.5
Combi
10.8
Dual
5.0
5.0
2.5
14.1
13.0
12.0
5.5
5.5
7.5
2.5
Angled
Dual Milling
Direct-Casting
Screw
Diagram above indicates the minimum height required for SuperLine / IMPLANTIUM prosthetic abutment.
Gingival Height
Preparable Amount
1.5mm
2.0
2.5mm
3.0
3.5mm
4.0
4.5mm
5.0
5.5mm
6.0
91
92
Prosthetic Procedure 1
Impression Technique and Restoration Selection
Combi Abutment
Dual Abutment
Impression Coping
Transfer (Snap on) 4.5 / 5.5 / 6.5
Analog
Analog
Burn-out Cylinder
Bridge
Single
Rotational
Non-rotational
Modification
Cemented Restoration
93
Clinical Procedure
Cover Screw
Healing Abutment
Dual Abutment
Comfort Cap
Temporary
Restoration
or Comfort Cap
Abutment Level
Impression
Chairside
Impression taking
94
Laboratory Procedure
Gold Crown
Porcelain
Crown
Cylinder
Crown Wax-up
Final Restoration
Cementation Type
LabSide
Completion of wax-up
95
Metal framework
Porcelain build-up
SCRP: O nce an access hole has been created, it can be converted to a SCRP (Screw
& Cemented Retained Prosthesis).
Final prosthesis
Metal framework
Final prosthesis
96
Impression taking
Injection of impression material
Impression taking
Inner-surface of impression
LabSide
97
Wax-up
Completed framework
Porcelain build-up
final prosthesis
Chairside
*If the combi analog is trimmed due to limited inter-occlusal space in the lab, make a reduction jig. Then a slight
modify of the abutment in the oral cavity may be necessary to the height of the jig.
98
Prosthetic Procedure 2
Impression Technique and Restoration Selection
Non-hex
Hex
Non-hex
Hex / Non-hex
Hex / Non-hex
Analog
4.0 / 4.5
Dual
Abutment
Dual Milling
Abutment
Angled
Abutment
Direct-Casting
Abutment
Metal-Casting
Abutment
Temporary
Abutment
Hex / Non-hex
Hex / Non-hex
Hex / Non-hex
Hex / Non-hex
Hex / Non-hex
Hex / Non-hex
4.0 / 4.5
5.5 / 6.5 / 7.5
15/ 25
4.5 / 5.5
4.5
4.5
Modification
Modification
Cemented Restoration
Screw-Retained Restoration
99
Clinical Procedure
Healing Abutment
Impression Coping
Pick-up Type
Chairside
Impression taking
100
Laboratory Procedure
Gold
Crown
Porcelain
Crown
Height Modification of
Dual Abutment
Burn-out Cylinder
Crown Wax-up
Final Restoration
Cementation Type
Labside
Wax-up
Metal framework
101
Final prosthesis
* In the process of seating the prosthesis, the prosthesis can be rebounded by gingival tissue.
In this case it is advised to apply occlusal load on the prosthesis for 10~15 minutes.
SCRP- Labside
Wax-up
Metal framework
SCRP- Chairside
Final prosthesis
* In the process of seating the prosthesis, the prosthesis can be rebounded by gingival tissue.
In this case it is advised to apply occlusal load on the prosthesis for 10~15 minutes.
102
Clinical Procedure
Healing Abutment
Impression Coping
Transfer Type
Chairside
Impression taking
103
Laboratory Procedure
Gold
Crown
Porcelain
Crown
Height Modification of
Dual Abutment
Burn-out Cylinder
Crown Wax-up
Final Restoration
Cementation
Labside
104
Completion of wax-up
Chairside
Completed wax-up
Metal framework
SCRP- Labside
SCRP- Chairside
Final prosthesis
* In the process of seating the prosthesis, the prosthesis can be rebounded by gingival tissue.
In this case it is advised to apply occlusal load on the prosthesis for 10~15 minutes.
105
Clinical Procedure
Impression Coping
Transfer Type
Healing Abutment
Chairside
Impression taking
Laboratory Procedure
Modification
Crown Wax-up
Final Restoration
Cementation
106
Master cast
Completion of wax-up
Metal framework
Chairside
Final prosthesis
* I n the process of seating the prosthesis, the prosthesis can be rebounded by gingival tissue.
In this case it is advised to apply acclusal load on the prosthesis for 10~15 minutes.
107
Clinical Procedure
Angled Abutment
Chairside
Impression taking
(individual tray with holes)
Removed impression
Laboratory Procedure
Angled Abutment
Connection
Modification
Crown Wax-up
Final Restoration
Cementation
108
Master cast
Wax-up
Chairside
Final prosthesis
109
Laboratory Procedure
Direct-Casting Abutment
Connection
Modification
Abutment Wax-up
Final Restoration
Cementation
Labside
Wax-up
Metal framework
Chairside
Final prosthesis
110
Laboratory Procedure
Metal-Casting Abutment
Connection
Modification
Abutment Wax-up
Final Restoration
Cementation
Labside
Wax-up
Metal framework
Chairside
Final prosthesis
111
Ti-Temporary Abutment
<Using Ti Abutment>
112
Prosthetic Procedure 3
Impression Technique and Restoration Selection
Screw Abutment
Abutment Level Impression
Screw Abutment
4.5 / 5.5
hex / Non-hex
4.5 / 5.5
Analog
4.5 / 5.5
Burn-out Cylinder
Gold Cylinder
Metal Cylinder
Titanium Cylinder
4.5 / 5.5
4.5 / 5.5
4.5 / 5.5
4.5 / 5.5
Bridge
Single
Bridge
Single
Bridge
Single
Bridge
Single
(Non-hex)
(Hex)
(Non-hex)
(Hex)
(Non-hex)
(Hex)
(Non-hex)
(Hex)
Polishing Protector
Temporary Restoration
4.5 / 5.5
Ti-Retaining Screw
Screw-Retained Restoration
113
Clinical Procedure
Cover Screw
Healing Abutment
Screw Abutment
Impression Coping
Transfer Type
Abutment Level
Impression
Chairside
Impression taking
Inner-surface of impression
114
Laboratory Procedure
Cylinder Connection
Modification
Crown Wax-up
Final Restoration
Screw Retained
Labside
Wax-up
115
Metal framework
Completion of porcelain
116
Final prosthesis
117
118
Prosthetic Procedure 4
Impression Technique and Restoration Type
Overdenture Procedure
Positioner / Mini Ball / Magnetic Attachment
Positioner
Implant Keeper
3.5
3.5
4.5 / 5.5
Positioner Analog
Positioner Attachment
for Overdenture
Socket Spacer
Magnetic Assay
Magnetic Attachment
for Overdenture
119
Positioner
Chairside
Labside
Positioner Analog
120
Positioner
Case 1
Chairside
Case 2
Chairside
121
Ball Attachment
Case 1
Chairside
Case 2
Chairside
122
Magnetic Attachment
Chairside
Case 1
123
Magnetic Attachment
Case 2
126
127
HEAD OFFICE
501 Gyeonggi R&DB Center, 105 Gwanggyo-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, Korea [443-270]
T +82-31-888-5431 F +82-31-888-5430
E-mail biz_mail@dentium.com / www.dentium.com