You are on page 1of 3

Page 1 of 3

PROJECT NAME:

DONE BY:

CHK BY:

DATE: JAN 4TH . 2015


REVISION:

TITLE:

Reference

Output

The applicable building code specifies the use of ASCE/ISEI 7 for


calculation of loads. The required strengths at the face of the column and
the centerline of the Beam in question are determined by a second order
analysis including the effects of P and P with reduced stiffness as
required by the direct analysis method .
The governing load combinations for the required flexural and shear
strength at the face of the column are:
LRFD Load combination 5 :
Mu= 1.2+ 0.2SDS)D +Qe + L + 0.2S

12.4.2.3

=
L=

0.918
20.21 k-ft
1.3
6.5 k-ft

Qe=

3
59.95 k-ft

Mu=

89.35 k-ft

SDS=
D=
12.3.4
Table 12.21

12.4.2.3

1.2+ 0.2SDS)D +Qe + L + 0.2S

LRFD Load combination 5:


Vu=1.2+ 0.2SDS)D +Qe + L + 0.2S

12.4.2.3

SDS=
D=
=
L=

0.918
5.8 kips
1.3
1.9

Qe=

3
6.85 kips

Vu=

18.72 kips

Page 2 of 3

PROJECT NAME:

DONE BY:

CHK BY:

DATE: JAN 4TH . 2015


REVISION:

TITLE:

Reference

Output
The governing load combinations for the required flexural and shear
strenght at the centerline of the beam are :
LRFD Load combination 5:
SDS=
0.918
D=
18.53 k-ft
=
1.3
L=
7.1 k-ft

3
Qe=
0 k-ft

12.4.2.3

1.2+ 0.2SDS)D +Qe + L + 0.2S

Mu=

48 k-ft

FROM AISC MANUAL TABLE 2-4


Column = W14x68
d=
A=
Zx=
h/tw
tw=
rx=
bf=
bf/2tf=
Ix=
ry=
tf=
Iy
Sx
kdes =
E
Fy=
Length of beam=

14
20
115
27.5
0.415
6.01
10
6.97
722
2.46
0.72
121
103
1.31
29000
50

in
in2
in3
in
in
in

in4
in
in
in4
in3
in
ksi
ksi
20 ft

BEAM ELEMENT SLENDERNESS:


AISC Seismic Provisions Section E3.5a requires that the stiffened and
unstiffened elements of SMF columns satisfy the requirements of Section
DI. l for highly ducutile members
hd=0.30 (E/Fy)

hd=
Because hd=

7.22495675
7.22495675 >

6.97 =f

FLANGES SATISFY THE REQUIREMENTS FOR HIGHLY DUCTILE


ELEMENTS

Okay

Page 3 of 3

PROJECT NAME:

DONE BY:

CHK BY:

DATE: JAN 4TH . 2015


REVISION:

TITLE:

Reference

Output
From AISC Seismic Provisions Table D 1.1, for webs of rolled I-shaped
sections used as beams or columns, recognizingtbat Ca = Pu/(Pn) is
assumed to be zero because no axial force is present for the beam, the
limiting width-to-thickness ratio is:

Table D
1.1

hd=2.45E/Fy

hd=

59.00

Because w=h/tw=

27.5 >

59 =hd

Okay

THE WEB SATISFIES THE REQUIREMENT FOR HIGHLY DUCTILE


Spacing Of lateral Bracing :
AISC Seismic Provision section D1.2b Requires that both flanges be
Laterally Braced at interavls not to exceed lbmax :

Lbmax= 0.08ry(E/Fy)

Unbraced length =
Lbmax=

10 ft.
10.2254 ft.

>

10 ft

lb

Okay

LATERAL BRACING IS NOT REQUIRED

Available and required flexural strenght at the centreline of the beam and
at the face of the column :

At the Beam centreline :


Mp= FyZx

431.25 kip-ft >

48 kip-ft

Okay

THE BEAM HAS SUFFICIENT FLEXURAL STRENGTH

At Column Face :
Mp= FyZx

431.25 kip-ft >

89.3 kip-ft

Okay

The Beam Has Sufficient Flexural Strength

AVAILABLE SHEAR STRENGTH:


Using AISC Manual Table 3-2 For the

W14x68

Vn =

>

175 kips

beam

18.7 kips

Okay

You might also like