Professional Documents
Culture Documents
Parmetros constantes
m/s
4.561
4.100
49.896
102.000
1.500
m/m
20.543
0.00080
m/m
2.429
Gravedad (g):
9.806
m/s
Espejo (T):
17.782
n Manning:
0.025
Velocidad (V):
2.044
m/s
Coef. energa:
1.120
4.774
Nm/N
Talud (Z):
Pendiente (S0):
Parmetros calculados
Caudal recalculado
Caudal (Q):
4.560532907
102.000
Parmetros calculados
m/s
2.925
4.100
24.825
Talud (Z):
1.500
m/m
14.646
Coef. energa:
1.120
1.695
Espejo (Tc):
12.875
Velocidad (Vc):
4.109
m/s
Yn= 4.561
0.390
Tipo de Flujo:
4.100
4.100
Subcrtico
4.561
dy/dX:
2.925
Tipo de flujo:
Nmero de Froude:
Y
4.652
Tipo de perfil:
0.390
Tipo de curva:
Remanso
Tipo de flujo:
Subcrtico
0.00080
0.00522
m/m
m/m
Perfil hidrulico:
M1
0.1518747
>
4.561
2.925
0.000800
>
2.925
4.561
Nmero de tramos:
20
4.652
5.520
R^ (4/3)
V (m)
V2/2g
E (m)
E (m)
sf
4.035
1.493
0.127
5.647
0.000345
23.846
4.000
1.512
0.131
5.607
-0.040
X (m)
X (m)
0.000357
0.000351
-89.172
-89.172
23.690
3.964
1.533
0.134
5.567
-0.040
23.533
3.929
1.553
0.138
5.528
-0.040
0.000370
0.000364
-91.489
-180.661
0.000384
0.000377
-94.054
23.377
3.894
1.574
0.142
5.488
-274.714
-0.040
0.000398
0.000391
-96.907
23.220
3.858
1.596
0.145
-371.621
5.448
-0.040
0.000412
0.000405
-100.098
-471.720
23.063
3.823
1.618
22.907
3.788
1.640
0.149
5.409
-0.039
0.000428
0.000420
-103.689
-575.408
0.154
5.370
-0.039
0.000444
0.000436
-107.756
22.750
3.753
-683.164
1.663
0.158
5.331
-0.039
0.000460
0.000452
-112.397
60.494
22.594
-795.561
3.718
1.686
0.162
5.292
-0.039
0.000478
0.000469
-117.740
59.651
-913.300
22.437
3.683
1.710
0.167
5.253
-0.039
0.000496
0.000487
-123.952
-1037.252
5.042
4.999
58.814
22.281
3.648
1.734
0.172
5.214
-0.039
0.000515
0.000506
-131.257
-1168.509
57.982
22.124
3.613
1.759
0.177
5.176
-0.038
0.000535
0.000525
-139.968
2.925
4.956
-1308.477
57.156
21.968
3.578
1.785
0.182
5.138
-0.038
0.000556
0.000546
-150.522
4.561
2.925
-1458.999
4.912
56.335
21.811
3.544
1.811
0.187
5.099
-0.038
0.000578
0.000567
-163.564
4.561
-1622.563
2.925
4.869
55.520
21.655
3.509
1.837
0.193
5.062
-0.038
0.000601
0.000590
-180.078
-1802.641
4.561
2.925
4.825
54.711
21.498
3.475
1.864
0.198
5.024
-0.038
0.000625
0.000613
-201.642
-2004.283
4.561
2.925
4.782
53.907
21.342
3.440
1.892
0.204
4.986
-0.037
0.000650
0.000638
-230.967
-2235.250
4.561
2.925
4.739
53.109
21.185
3.406
1.921
0.211
4.949
-0.037
0.000677
0.000664
-273.119
-2508.369
4.561
2.925
4.695
52.317
21.029
3.371
1.950
0.217
4.912
-0.037
0.000705
0.000691
-338.807
-2847.176
4.561
2.925
4.652
51.530
20.872
3.337
1.979
0.224
4.875
-0.037
0.000734
0.000719
-455.239
-3302.415
2.925
4.561
2.925
5.477
4.561
2.925
5.433
4.561
2.925
5.390
Sc
4.561
2.925
5.346
0.005221
4.561
2.925
5.303
4.561
2.925
5.260
4.561
2.925
5.216
Sf
4.561
2.925
5.173
A (m2)
68.338
67.444
66.555
65.672
64.795
63.924
63.058
62.198
61.343
0.000345
4.561
2.925
5.129
4.561
2.925
5.086
4.561
2.925
4.561
2.925
4.561
6.000
5.000
4.000
Y (M)
P (m)
Y
5.520
Perfil hidrulico
24.003
Yc
2.925
Pendientes (m/m)
S0
Yn
Criterios de flujo
Perfiles hidrulicos
4.561
S0
<
4.652
Yc
Pendientes (m/m)
0.000800
5.520
4.561
>
Tirantes (m)
<
Yn
>
Yn
M1
F2
Suave
Subcrtico
2.9249247
Yc= 2.925
102.000 m/s
Nmero de Froude:
Tirante (Y):
3.000
2.000
1.000
0.000
-3500
-3000
-2500
-2000
-1500
ABSCISA (M)
-1000
-500
Perfil hidrulico M1
El flujo es subcrtico; aguas arriba, la pendiente del perfil de flujo tiende a cero, y el flujo tiende asintticamente al flujo uniforme; el perfil de flujo no
puede tener concavidad hacia abajo, ni ser una lnea recta, sino de concavidad hacia arriba. Se presenta detrs de una represa, vertedero y
compuertas. Su longitud puede ser de varios kilmetros extendindose aguas arriba desde la estructura e control hasta una seccin en la que el
tirante difiera en uno o dos por ciento respecto al tirante normal.
Parmetros constantes
m/s
4.561
4.100
49.896
102.000
1.500
m/m
20.543
0.00080
m/m
2.429
Gravedad (g):
9.806
m/s
Espejo (T):
17.782
n Manning:
0.025
Velocidad (V):
2.044
m/s
Coef. energa:
1.120
4.774
Nm/N
Talud (Z):
Pendiente (S0):
Parmetros calculados
Caudal recalculado
Caudal (Q):
4.560532907
102.000
Parmetros calculados
m/s
2.925
4.100
24.825
Talud (Z):
1.500
m/m
14.646
Coef. energa:
1.120
1.695
Espejo (Tc):
12.875
Velocidad (Vc):
4.109
m/s
Yn= 4.561
0.390
Tipo de Flujo:
4.100
Subcrtico
4.100
4.561
dy/dX:
2.925
Tipo de flujo:
Nmero de Froude:
Yn
4.561
Tipo de perfil:
0.390
Tipo de curva:
Cada
Tipo de flujo:
Subcrtico
0.00080
0.00522
m/m
m/m
Perfil hidrulico:
M2
0.1518747
<
>
2.925
>
4.561
2.925
0.000800
0.000800
<
4.561
Nmero de tramos:
20
4.515
2.926
P (m)
R^ (4/3)
V (m)
V2/2g
E (m)
E (m)
sf
14.646
2.021
4.109
0.964
3.889
0.005220
14.933
2.079
3.945
0.889
3.893
0.004
X (m)
X (m)
0.004677
0.004948
-0.967
-0.967
15.219
2.138
3.790
0.821
3.904
0.011
15.506
2.197
3.645
0.759
3.922
0.018
0.004200
0.004438
-3.126
-4.093
0.003781
0.003990
-5.604
15.792
2.256
3.509
0.703
3.946
-9.696
0.024
0.003411
0.003596
-8.455
-18.151
16.078
2.315
3.380
0.652
16.365
2.375
3.258
0.606
3.975
0.029
0.003084
0.003248
-11.748
-29.899
4.008
0.033
0.002794
0.002939
-15.571
16.651
2.434
3.143
-45.470
0.564
4.045
0.037
0.002537
0.002666
-20.034
16.938
2.494
3.034
-65.504
0.526
4.086
0.041
0.002307
0.002422
-25.285
-90.789
34.798
17.224
2.554
36.001
17.511
2.614
2.931
0.491
4.131
0.044
0.002102
0.002205
-31.516
-122.305
2.833
0.458
4.178
0.047
0.001919
0.002011
-38.990
37.223
17.797
2.675
-161.295
2.740
0.429
4.228
0.050
0.001755
0.001837
-48.077
3.878
38.463
18.084
-209.372
2.735
2.652
0.402
4.280
0.052
0.001607
0.001681
-59.303
2.925
3.958
39.723
-268.675
18.370
2.796
2.568
0.377
4.334
0.054
0.001474
0.001540
-73.461
4.561
2.925
4.037
-342.135
41.001
18.656
2.857
2.488
0.353
4.391
0.056
0.001354
0.001414
-91.784
4.561
2.925
-433.920
4.117
42.299
18.943
2.919
2.411
0.332
4.449
0.058
0.001245
0.001299
-116.320
-550.240
5.000
4.561
4.500
4.561
2.925
4.196
43.615
19.229
2.980
2.339
0.312
4.508
0.060
0.001147
0.001196
-150.719
-700.959
2.925
4.276
44.951
19.516
3.042
2.269
0.294
4.570
0.061
0.001058
0.001103
-202.194
4.000
-903.153
4.561
2.925
4.355
46.305
19.802
3.104
2.203
0.277
4.632
0.062
0.000977
0.001018
-287.273
-1190.426
4.561
2.925
4.434
47.678
20.089
3.166
2.139
0.261
4.696
0.064
0.000904
0.000940
-453.984
-1644.410
4.561
2.925
4.514
49.070
20.375
3.228
2.079
0.247
4.761
0.065
0.000837
0.000870
-925.277
-2569.687
Yc
Y
2.925
2.925
4.561
2.925
3.004
4.561
2.925
3.084
4.561
2.925
3.163
Sc
4.561
2.925
3.243
0.005221
4.561
2.925
3.322
4.561
2.925
3.402
4.561
2.925
3.481
Sf
4.561
2.925
3.561
0.005220
4.561
2.925
3.640
4.561
2.925
3.719
4.561
2.925
3.799
4.561
2.925
4.561
Perfil hidrulico
2.925
2.925
Pendientes (m/m)
S0
Yn
Criterios de flujo
Perfiles hidrulicos
4.561
S0
<
2.925
Yc
Pendientes (m/m)
>
Tirantes (m)
Yn
M2
F2
Suave
Subcrtico
2.9249247
Yc= 2.925
102.000 m/s
Nmero de Froude:
Tirante (Y):
3.500
A (m2)
24.826
25.858
26.910
27.980
29.069
30.177
31.304
32.450
33.615
Y (M)
3.000
2.500
2.000
1.500
Perfil hidrulico M2
El flujo es subcrtico, se produce una cada hidrulica; El flujo tiende a ser uniforme. Se desarrolla en pendiente suave, cuando el tirante se reduce en
el sentido del flujo, por ejemplo un estrechamiento de la seccin o en la proximidad de una rpida.
1.000
0.500
0.000
-3000
-2500
-2000
-1500
ABSCISA (M)
-1000
-500
Parmetros constantes
m/s
4.548
4.150
49.901
102.000
1.500
m/m
20.548
Pendiente (S0):
0.00080
m/m
2.428
Gravedad (g):
9.806
m/s
Espejo (T):
17.794
n Manning:
0.025
Velocidad (V):
2.044
m/s
Coef. energa:
1.150
4.761
Nm/N
Abertura (Ya):
2.230
0.6000
Talud (Z):
Parmetros calculados
Caudal recalculado
Caudal (Q):
4.547992596
102.000
Parmetros calculados
m/s
2.935
4.150
25.096
Talud (Z):
1.500
m/m
14.731
Coef. energa:
1.150
1.704
Espejo (Tc):
12.954
Velocidad (Vc):
4.064
m/s
Yn= 4.548
2.93454492
Yc= 2.935
102.000 m/s
Nmero de Froude:
0.390
Tipo de Flujo:
Subcrtico
4.150
4.150
2.925
4.548
2.935
Tipo de flujo:
Suave
dy/dX:
Yn
4.548
Tipo de perfil:
Subcrtico
0.390
Tipo de curva:
Remanso
0.00080
m/m
Tipo de flujo:
Supercrtico
Yn
0.00507
m/m
Perfil hidrulico:
M3
4.548
Nmero de Froude:
>
Yc
2.935
2.935
1.338
2.925
2.935
4.548
Nmero de tramos:
20.000
A (m2)
8.238
8.899
9.580
10.279
10.998
11.736
12.492
13.268
14.063
P (m)
R^ (4/3)
V (m)
V2/2g
E (m)
E (m)
sf
8.974
0.892
12.382
8.989
10.327
0.107397
9.262
0.948
11.462
7.703
9.121
-1.206
>
2.925
Tirantes (m)
>
Yn
Yc
Yc
4.548
2.935
1.338
2.935
4.548
2.935
1.418
0.086596
X (m)
X (m)
12.541
12.541
0
0.096997
9.550
1.004
10.647
6.648
8.145
-0.976
0.070561
0.078579
12.542
25.084
9.838
1.060
9.923
5.774
7.351
-0.794
0.058041
0.064301
12.506
37.589
10.126
1.116
9.275
5.044
6.701
-0.650
0.048152
0.053096
12.430
50.020
10.413
1.173
8.692
4.430
6.167
-0.534
0.040258
0.044205
12.312
62.331
10.701
1.229
8.165
3.909
5.726
-0.441
0.033897
0.037078
12.147
74.478
10.989
1.286
7.687
3.465
5.362
-0.364
0.028727
0.031312
11.931
86.409
11.277
1.342
7.253
3.085
5.061
-0.301
0.024492
0.026609
11.659
98.068
14.878
11.565
1.399
6.856
2.756
4.813
-0.249
0.020996
0.022744
11.327
109.395
15.711
11.852
1.456
6.492
2.472
4.608
-0.205
0.018092
0.019544
10.926
120.321
16.563
12.140
1.513
6.158
2.224
4.440
-0.168
0.015663
0.016877
10.451
130.772
2.296
17.435
12.428
1.570
5.850
2.007
4.303
-0.137
0.013621
0.014642
9.893
140.664
2.935
2.376
18.326
12.716
1.628
5.566
1.817
4.192
-0.111
0.011894
0.012758
9.242
149.906
4.548
2.935
2.456
19.235
13.004
1.685
5.303
1.649
4.104
-0.088
0.010427
0.011161
8.489
158.395
4.548
2.935
2.535
20.164
13.292
1.743
5.058
1.500
4.036
-0.069
0.009174
0.009801
7.620
166.015
4.548
2.935
2.615
21.112
13.579
1.801
4.831
1.369
3.984
-0.052
0.008100
0.008637
6.622
172.637
4.500
4.548
2.935
2.695
22.080
13.867
1.859
4.620
1.251
3.946
-0.037
0.007174
0.007637
5.478
178.115
4.000
4.548
2.935
2.775
23.066
14.155
1.918
4.422
1.147
3.922
-0.025
0.006374
0.006774
4.168
182.283
4.548
2.935
2.855
24.071
14.443
1.976
4.237
1.053
3.908
-0.014
0.005679
0.006027
2.671
184.953
4.548
2.935
2.935
25.096
14.731
2.035
4.064
0.969
3.903
-0.004
0.005074
0.005377
0.958
185.911
F2
0.1519379
<
S0
M3
4.548
2.935
1.498
4.548
2.935
1.577
Sc
4.548
2.935
1.657
0.005074
4.548
2.935
1.737
4.548
2.935
1.817
4.548
2.935
1.897
Sf
4.548
2.935
1.977
0.107397
4.548
2.935
2.056
4.548
2.935
2.136
4.548
2.935
2.216
4.548
2.935
4.548
Pendientes (m/m)
0.000800
<
Criterios de flujo
Pendientes (m/m)
S0
Perfiles hidrulicos
0.000800
<
Perfil hidrulico
5.000
3.500
Y (M)
3.000
2.500
2.000
1.500
Perfil hidrulico M3
El flujo es supercrtico; El perfil del flujo se eleva en el sentido de la corriente, es decir, la profundidad aumenta corriente abajo; ocurre un Resalto
Hidrulico. Se encuentra aguas debajo de un cambio de pendiente de supercrtica a subcrtica, o despus de la descarga de una compuerta con
pendiente suave. Esta regido por las condiciones aguas abajo y termina normalmente en un resalto.
1.000
0.500
0.000
0
20
40
60
80
100
ABSCISA (M)
120
140
160
180
200
Parmetros constantes
m/s
2.380
4.100
18.258
102.000
1.500
m/m
12.682
0.01200
m/m
1.440
Gravedad (g):
9.806
m/s
Espejo (T):
11.241
n Manning:
0.025
Velocidad (V):
5.587
m/s
3.972
Nm/N
Talud (Z):
Pendiente (S1):
Parmetros calculados
Coef. energa:
1.120
Pendiente (S1):
0.01200
m/m
Caudal recalculado
Caudal (Q):
2.380283106
102.000
Parmetros calculados
m/s
2.925
4.100
24.825
Talud (Z):
1.500
m/m
14.646
Coef. energa:
1.120
1.695
Espejo (Tc):
12.875
Velocidad (Vc):
4.109
m/s
Yn= 2.380
1.400
Tipo de Flujo:
4.100
4.100
Supercrtico
2.380
dy/dX:
2.925
Tipo de flujo:
Nmero de Froude:
Yc
2.925
Tipo de perfil:
1.400
Tipo de curva:
Cada
Tipo de flujo:
Supercrtico
0.01200
m/m
0.00522
m/m
Perfil hidrulico:
1.9595823
>
Yn
<
2.380
S0
S2
2.925
>
0.012000
>
2.380
0.012000
>
2.925
2.380
Nmero de tramos:
20
2.404
2.925
P (m)
R^ (4/3)
V (m)
V2/2g
E (m)
E (m)
sf
14.646
2.021
4.109
0.964
3.889
0.005221
14.552
2.002
4.165
0.991
3.889
0.000
X (m)
X (m)
0.005416
0.005318
0.068
0.068
14.458
1.983
4.222
1.018
3.891
0.001
14.364
1.964
4.281
1.046
3.893
0.002
0.005619
0.005518
0.215
0.283
0.005832
0.005726
0.378
14.270
1.945
4.340
1.076
3.897
0.660
0.003
0.006055
0.005944
0.559
14.176
1.926
4.402
1.106
1.220
3.901
0.004
0.006288
0.006172
0.764
1.984
14.083
1.907
4.464
13.989
1.888
4.528
1.138
3.907
0.006
0.006532
0.006410
0.996
2.980
1.171
3.913
0.007
0.006788
0.006660
1.260
13.895
1.869
4.240
4.593
1.205
3.921
0.008
0.007056
0.006922
1.564
21.890
13.801
5.804
1.850
4.660
1.240
3.931
0.009
0.007337
0.007196
1.918
21.574
7.723
13.707
1.831
4.728
1.277
3.941
0.011
0.007631
0.007484
2.335
10.058
2.638
2.612
21.260
13.613
1.812
4.798
1.315
3.953
0.012
0.007940
0.007786
2.832
12.890
20.948
13.519
1.793
4.869
1.354
3.966
0.013
0.008265
0.008102
3.436
2.925
2.586
16.326
20.638
13.425
1.774
4.942
1.395
3.981
0.015
0.008605
0.008435
4.185
2.380
2.925
20.512
2.560
20.330
13.331
1.755
5.017
1.438
3.998
0.017
0.008963
0.008784
5.137
2.380
25.648
2.925
2.534
20.024
13.237
1.736
5.094
1.482
4.016
0.018
0.009339
0.009151
6.387
32.035
2.380
2.925
2.508
19.721
13.144
1.718
5.172
1.528
4.036
0.020
0.009734
0.009537
8.101
40.136
2.380
2.925
2.482
19.419
13.050
1.699
5.253
1.576
4.058
0.022
0.010150
0.009942
10.594
50.730
2.380
2.925
2.456
19.119
12.956
1.680
5.335
1.625
4.082
0.024
0.010588
0.010369
14.553
65.283
2.380
2.925
2.430
18.822
12.862
1.661
5.419
1.677
4.107
0.026
0.011048
0.010818
21.806
87.089
2.380
2.925
2.404
18.526
12.768
1.643
5.506
1.731
4.135
0.028
0.011534
0.011291
39.376
126.465
Yn
Yc
2.925
2.925
2.925
2.380
2.925
2.899
2.380
2.925
2.873
2.380
2.925
2.847
Sc
2.380
2.925
2.821
0.005221
2.380
2.925
2.795
2.380
2.925
2.769
2.380
2.925
2.743
Sf
2.380
2.925
2.717
A (m2)
24.825
24.490
24.158
23.828
23.500
23.174
22.850
22.528
22.207
0.005221
2.380
2.925
2.691
2.380
2.925
2.664
2.380
2.925
2.380
2.925
2.380
Perfil hidrulico
3.500
2.380
Pendientes (m/m)
S0
2.925
Yc
Criterios de flujo
Perfiles hidrulicos
Pendientes (m/m)
>
Tirantes (m)
S2
F2
Empinada
Supercrtico
2.92492469
Yc= 2.925
102.000 m/s
Nmero de Froude:
Tirante (Y):
3.000
2.500
Y (M)
2.000
1.500
1.000
0.500
0.000
0
20
40
60
80
ABSCISA (M)
100
120
140
Perfil hidrulico S2
El flujo es supercrtico; el perfil de flujo se abate en el sentido de la corriente, es decir, la profundidad disminuye corriente abajo; cambio de
concavidad debido al paso de un perfil de flujo subcrtico a un perfil. Supercrtico. Se encuentra a la entrada de un tramo de gran pendiente o aguas
abajo de un cambio de pendiente de suave a fuerte. Su longitud es generalmente corta, extendindose desde la seccin de control (tirante crtico)
hacia aguas abajo, hasta una seccin en la que el tirante es mayor en uno o dos por ciento respecto al tirante normal.
Parmetros constantes
m/s
Parmetros clculados
Tirante normal (Yn):
0.791
Caudal (Q):
7.136
m/s
1.326
Dimetro ():
1.829
1.089
Dimetro ():
1.829
2.039
Pendiente (S):
0.0200
m/m
2.626
Gravedad (g):
9.806
m/s
3.726
n Manning:
0.012
0.415
0.547
Gravedad (g):
9.806
Espejo (T):
1.812
Coef. energa:
1.000
Velocidad (V):
6.554
m/s
2.981
Nm/N
7.1358450
m/s
Caudal (Q):
m/s
Nmero de Froude:
Tipo de Flujo:
0.791235
1.829
Yn= 0.791
1.633
3.499
m/s
1.950
Nm/N
Nmero de Froude:
1.00
164.5
0.791
dy/dX:
1.326
Tipo de flujo:
Nmero de Froude:
Yc
1.326
Tipo de perfil:
Zona del flujo:
2.700
Tipo de curva:
Cada
Tipo de flujo:
Supercrtico
0.02000
m/m
0.00394
m/m
233.5
0.841
1.326
Empinada
Supercrtico
1.829
Yc= 1.326
1.32569012
Espejo (T):
Velocidad (V):
2.700
Supercrtico
Tirante (Y):
Perfil hidrulico:
F2
7.2898037
>
1.325
Yn
<
0.000
0.791
S0
S2
0.020000
>
0.012000
1.326
Nmero de tramos:
Yc
0.791
1.326
1.326
233.4607
0.791
1.326
1.265
225.1003
0.791
1.326
1.204
216.9864
0.791
1.326
1.144
209.0605
Sc
0.791
1.326
1.083
201.2746
0.003938
0.791
1.326
1.023
193.5869
0.791
1.326
0.962
185.9604
0.791
1.326
0.901
178.3602
0.791
1.326
0.841
170.7527
Sf
>
0.791
Pendientes (m/m)
S0
Yc
Criterios de flujo
Perfiles hidrulicos
Yn
Pendientes (m/m)
1.325
Yn
>
Tirantes (m)
S2
>
8
2
A (m )
2.039
1.939
1.835
1.728
1.620
1.511
1.400
1.289
1.179
P (m)
R^ (4/3)
V (m)
V2/2g
E (m)
E (m)
sf
3.726
0.448
3.499
0.624
1.950
0.000008
3.592
0.439
3.681
0.691
1.956
0.006
3.463
0.429
3.889
0.771
1.976
3.336
0.416
4.128
0.869
2.013
3.212
0.402
4.404
0.989
2.072
3.090
0.385
4.723
1.138
2.968
0.367
5.096
2.847
0.348
5.534
2.725
0.327
6.054
1.869
X (m)
X (m)
0.497
0.000008
0.000008
0.497
0.020
0.000008
0.000008
1.649
0.037
0.000007
0.000008
3.097
5.242
0.059
0.000007
0.000007
4.945
10.187
2.160
0.088
0.000007
0.000007
7.340
17.527
1.324
2.286
0.126
0.000007
0.000007
10.498
28.026
1.562
2.463
0.177
0.000006
0.000006
14.740
42.765
2.709
0.247
0.000006
0.000006
20.554
63.319
0.000008
Perfil hidrulico
1.400
1.200
1.000
Y (M)
0.800
0.600
0.400
0.200
0.000
0
10
20
30
40
ABSCISA (M)
50
60
70
Perfil hidrulico S2
El flujo es supercrtico; el perfil de flujo se abate en el sentido de la corriente, es decir, la profundidad disminuye corriente abajo; cambio de concavidad debido al paso de un
perfil de flujo subcrtico a un perfil. Supercrtico. Se encuentra a la entrada de un tramo de gran pendiente o aguas abajo de un cambio de pendiente de suave a fuerte. Su
longitud es generalmente corta, extendindose desde la seccin de control (tirante crtico) hacia aguas abajo, hasta una seccin en la que el tirante es mayor en uno o dos por
ciento respecto al tirante normal.
2.146