You are on page 1of 7

Peru Engineering

Method of Procedure (MOP)


Date

25/08/2015

Ver.

Page

Last
Update

TSS E INSTALACION DE SOPORTE MW 1.20 M


0101204_TA_LOS_PALOS

[JEAN PIERRIE MEJIA ]


Designed by
COMFUTURA

Confidential

[CARLA ALVAREZ]
Approved by
O&M

Peru Engineering
Method of Procedure (MOP)
Date

25/08/2015

Page

Last
Update

Ver.

General Information
Proposed Date:

[20/05/2016~ 31/05/2016]

Proposed Time:

[Peru GMT-5 (09:00 hrs ~ 19:00 hrs)]

Activity Description:

Technical Site Survey

Activity Purpose:

Instalacin de soporte MW 1.20 M.

Network Type

iDEN

Network Domains
Involved:

RAN (Radio Access Network)


CS Core

Involved NEs:
Involved Services:

Involved Markets and


Providers:
Nextel NOC
Monitoring

3G

DATACOM

LTE

WiMax

Other: MW

Transport/Transmission
ISP

VAS

Sites

PS Core
Other:______________

NINGUNA EN PRODUCCION
TACNA

COMUNICACION FUTURA SAC

Sites & TX
VAS

Confidential

2G

Voice
Datacomm

Dispatch / ISP / HPPTT / CWAN

Peru Engineering
Method of Procedure (MOP)
Date

25/08/2015

Page

Last
Update

Ver.

RPN (Risk Priority


Number)
Location for
execution:

TACNA

Bridge (if needed):

NO SE REQUIERE
Onsite Support Required:

Facilities:

Yes

No:

Remote Support Required: Yes:

No:

Partners Support Required: Yes:

No:

Network Impact:

Yes:

Impact Duration:

No existir afectacin de servicios.

Notification to
OSIPTEL:

Yes:

No:

Date: []

Notification to
Providers:

Yes:

No:

Date: []

Impacted NEs:
Impacted Services:

N/A

Impacted Markets
and Providers:

N/A

Confidential

No:

Places (if yes): []

Contact Info: []

Peru Engineering
Method of Procedure (MOP)
Date

25/08/2015

Page

Last
Update

Ver.

Ticket or Case
reference (if any):
Comments and
remarks:

MOP Scope and


Detailed
Description

N/A

Instalacin de soporte MW 1.20 m.


Sitio
La_Yarada

Fecha Plan

Fecha Backup

20/May

31/May

Pre-conditions
in the Network

Que no existan cortes de energa ni cadas de servicio.

General
Expected
Results

Instalacion de soporte MW 1.20 m

Pre Works

Confidential

Attach test matrix and necessary checklist:


1. Arribar al sitio.

Peru Engineering
Method of Procedure (MOP)
Date

Attach Hour by Hour Activity:


Owner
Step

Date

Description
Inspeccin de instalacin

1
Abrir evento con TIER 1 Entel.
2

Cooperad
or

TSS e Instalacin de Soporte

Cooperad
or

Tomas fotogrficas

Cooperad
or

Cierre de evento con TIER 1

Cooperad
or

Command
Configuration

20/05/201
6/
20/05/201
6
20/05/201
6/
20/05/201
6
20/05/201
6/
20/05/201
6
20/05/201
6/
20/05/201
6

Attach the scripts and commands sequence:


1. [Item1]
2. [Item2]

Validation

Attach test matrix and necessary validations:


1. [Item1]
2. [Item2]

Confidential

Last
Update

Ver.

MOP Activities
Description

Page

25/08/2015

Referenc
e Start
Time
-

Reference
End Time

09:00 AM

09:10 AM

09:10 AM

12:00 AM

12:00 PM

1:00 PM

5:00 PM

5:30 PM

Peru Engineering
Method of Procedure (MOP)
Date

25/08/2015

Ver.

Page

Last
Update

Attach the GO / NO GO Criteria and escalation levels:


Go / No Go
Criteria

1. [Item1]
2. [Item2]

Attach the scripts and commands sequence:


Roll Back
Procedure

1. [Item1]
2. [Item2]

Roles &
The roles and responsibilities should be detailed below and some
Responsibilities additional information can be gathered including providers:
Contact name

Contact Number
/ UFMI

Area / Responsability

Jean Pierrie Mejia

972800893

CONTRATISTA

955243622

Coordinador de
Construccin de
Infraestructura Mvil

Carla Alvarez

Confidential

E-mail
supervision@comfutura.com
carla.alvarez@entel.pe

Peru Engineering
Method of Procedure (MOP)
Date

25/08/2015

Page

Last
Update

Ver.

Additional
Information:
Detallo personal a ingresar en los sitios de mencionados.
Apellidos y Nombres

Confidential

Documento de
Identidad

LAURA TOVAR, SAUL

10697026

AYALA MOSQUERA, PEDRO

16134267

TAIPE LLANOS, VICTOR MANUEL

41268930

SOLORZANO PAUCAR, EDUARDO

08634197

MEJIA VAN DYCK, JEAN

972800893

You might also like