You are on page 1of 18

siemens.

com/gasturbines

Reliable and powerful


economical, safe-investment packages
SGT6-PAC 5000F/SCC6-PAC 5000F

SGT6-PAC 5000F packages:


flexible answers to drive your business forward
Innovation for fossil power generation is our business.
As a technology leader, we are familiar with the global
energy markets, and always have a ready answer with
our future-oriented product portfolio in spite of constantly changing requirements.
We combine maximum performance with minimum
emissions, and we achieve high levels of energy efficiency
with minimized operating costs and calculable investments. And by continously investing in research and
development, we will ensure that this continues
intothefuture as well.

You will profit from our experience


With the comprehensive Siemens packages for the hightech gas turbine SGT6-5000F for combined cycle or simple
cycle applications, you will profit even before the plant
is commissioned. Gas turbine, generator, steam turbine,
and the corresponding auxiliary systems are combined
into aperfectly functioning unit and individually matched
to your specific project targets.
In this way we can significantly reduce the engineering
work required for coordinating interfaces and lower the
risks entailed in the performance and delivery of EPCs.
Individual components in our packages canalso be
combined with other manufacturers models with no
additional effort.

This is how we have made the SGT6-PAC 5000F and its


individual components the first choice for challenging
projects. Regardless of whether you need to compete
in OPEX- or CAPEX-driven markets or if you have to face
the challenges in markets with a high share of renewables, our power plant components will ensure that
you remain competitive.
In brief: in a dynamic energy market, the SGT6-PAC 5000F
is the economical and flexible answer to your project.

Flexibility
you can rely on
We have developed a variety of packages specifically for
our proven and reliable SGT6-5000F gas turbines 60 Hz
market. The SGT6-5000F itself is the core component of
every package. And because we know that every project
is different and poses its own individual requirements, we
supply a variety of different turbine and package options.
Performance or efficiency oriented, forcombined cycle
(SCC6-PAC 5000F) orsimple cycle (SGT6-PAC 5000F)
applications, ordesigned for IGCC application.
In addition to the gas turbine, you can also rely on
the performance of all the other market tested, topquality components in the SGT6-PAC 5000F package.
The SGen6-1000A generator and SST6-5000 steam
turbine work p
erfectly together with the gas turbine.

This enables you to get the full potential from all


components and achieve maximum cost efficiency,
whether in peak, intermediate, or base load duty.
The SGT6-5000F packages:
keeping the interfaces in mind
Forward looking technologies for competitive power
plant operation. WiththeSGT6-PAC 5000F and the
SCC6-PAC 5000F, you are right on track.
One of the attractive features of our packages is their
low lifecycle costs, thanks to the seamless coordination
of the individual components. This plays aninvaluable
role in helping operators stay competitive.

SGT6-PAC 5000F

SCC6-PAC 5000F

for simple cycle operation

for combined cycle operation

SGT6-5000F

SGen6-1000A

2xSGT6-5000F

3xSGen6-1000A

SST6-5000

Presentation is exemplary.

Additional applications are available, including MS 2x1 or MS 3x1 and MS 4x1, depending on specific requirements

SGT6-PAC 5000F and SCC6-PAC 5000F


your benefits at a glance
Security of investment: as a result of
the long-term availability of spare parts
and service and maintenance expertise
Minimized engineering and project
management costs thanks to accelerated
engineering: pre-engineered package
Shorter lead times for construction
and commissioning: standardized
package designs, predefined interfaces
to the overall power plant, utilization of
proven components
Plant design freedom: small footprint
of packaged components, predefined
interfaces to the overall power plant
Higher flexibility to fulfill both customerand site-specific requirements:
generator cooling options, dual fuel
option, air intake system, exhaust gas
system, and noise abatement

Scope of supply for SGT6-PAC 5000F


for simple cycle applications
typical installation

Scope of supply for SCC6-PAC 5000F


2x1 MS for combined cycle applications

SGT6-5000F (gas turbine)


SGen6-1000A (electrical generator)
Air intake system
Exhaust gas system
Start-up system
Major auxiliary system
Instrumentation and control
Electrical systems
Lubrication oil system
Hydraulic oil system
Turning gear
Compressor water wash skid
Piping packages
Cooling systems
Power control center
Enclosures
Fire protection

2xSGT6-PAC 5000F
(scope of supply identical to simple
cycle application for each SGT6-5000F)

The combined cycle application


also features
SST6-5000 (steam turbine) including
auxiliaries
SGen6-1000A including a
uxiliaries
Steam turbine electrical instrumentation
and control

Optional equipment is available customized to your project, such as


a dual fuel combustion system, inlet heating system, and much more
5

9
4

8
3
6

The SGT6-5000F:
world class reliability truly multitalented
Continuous flexibility, high performance and reliability,
high efficiency, and superior environmental indicators
are the requirements for electricity production today.
Meeting these challenges is no problem for the
SGT6-5000F and its various packages.
We are consistently working to make it even better,
which is why the SGT6-5000F is one of the best in class.

Key
1 Generator coupling
2 Variable guide vanes
3 Compressor rotating blades
4 Fuel nozzles
5 Combustors
6 Combustor transition
7 Turbine rotating blades
8 Turbine discs
9 Turbine casing

Its success proves us right


Since its market launch in 1993, the SGT6-5000F has
demonstrated world class reliability. An operating fleet
of 320 turbines with cumulative fired hours exceeding
ten million and a fleet reliability of consistently
99 percent speaks for itself. The SGT6-5000Fs world
class reliability isachieved through proven technology,
low F-class firing temperatures, and theuse of conventionally cast alloys inthe turbine. Despite its low firing
temperature, the SGT6-5000F packages deliver highlevel efficiency. However, the SGT6-5000F excels not
only in worldwide service, but also with remarkable
performance parameters. Best of all, as the core package
component, the SGT6-5000F also influences the equally
exceptional performance ofthe packages in simple cycle
as well as combined cycle applications.

Versatility you can count on


The SGT6-5000F is the basic component in numerous
different concepts in the area of fossil electricity generation. In the 60 Hz market, it is the first choice forsimple
cycle and combined cycle operation with orwithout
integrated gasification combined cycle (IGCC), combined
heat and power (cogeneration), and repowering.
The 13-stage high efficiency compressor and four-stage
turbine are on one central tie bolt rotor with Hirth
serration. The SGT6-5000F isdesigned to use a wide
range of different fuels. It runs on natural gas, low
ormedium calorific BTU gas, as well as on distillate oils
and there is no need to shut down the turbine when
switching from gas to liquidfuel.

Flexibility that enables you to react with


maximum efficiency
The need for flexible power generation has increased
dramatically over the years. The SGT6-5000F is the right
choice to meet those ever-changing energy demands.
The unique turbine design is always biased toward
high efficiency values. But in applications where power
has the a
bsolute top priority, we can rapidly increase
power output by an additional ten percent with Shaping
PowerTM this provides operating flexibility to respond
to changing grid demands without impacting part life.
And to provide even more flexibility the SGT6-5000F with
Shaping Power TM can also operate in max efficiency
mode with reduced fuel consumption.
The SGT6-5000F achieves short and c ost efficient start-up
times thanks to the fast start option. You can produce
power for the grid in five minutes and generate 150 MW
in ten minutes from turning gear speed. While connected

to the grid, the gas turbine can ramp at 30MW/min


with no service penalty. The low load turndown option
provides you with the flexibility to reduce load down to
< 40 percent of gas t urbine base load while maintaining
emissions compliance. This gives youthe benefits of
remaining cost effectively connected to the grid with
reduced fuel costs during off-peak hours, while also
avoiding start-up and shutdown costs. You are therefore
able to respond more quickly to changing grid demands.
You can always rely on the SGT6-5000F for consistent
performance with low emissions and high flexibility
in operation.
Environmental friendliness that allows you
to set benchmarks
Withnine ppm NOx without water injection and less than
four ppm CO, the SGT6-5000F boasts the lowest emission
values today. We achieve this through the Ultra Low NOx
(ULN) combustion system.

SGT6-5000F your benefits at a glance


Operating flexibility:

Cost efficiency:

Fuel flexibility natural gas with varying Wobbe index,


distillate oils, and syngas
Fuel changeover without shutting down
Rapid start-up and shutdown to quickly r espond to grid
demands to equalize n
etwork fluctuations
Fast, cost efficient start-up (five minutes tofull speed
no load from turning gear, and30 MW/min loading rates)

Optimal fuel utilization due to high efficiency


High power output (rated power output of up to 242 MW)
Best-in-class environmental performance:
Low emission gas turbines, single digit NOxand
CO operation, high efficiency levels
Low emissions even in part load operation

High availability and reliability:


Short inspection times thanks to maintenance friendly design.
For example, compressor blades can be easily removed and
replaced in the field, additionally there are special service
programs and support available during o
peration, such as
remote online diagnostics
More than 320 engines and ten million o
perating hours,
with more than 171,000 hours on the lead unit

The SST6-5000:
full steam ahead for your project
About 75 machines under contract, and about 16,500
installed MW. These figures speak for themselves
and for our extensive experience. We have developed the
SST6-5000 especially for operation incombined cycle
power plants and coal fired steam power plants.
Customized designs you can count on
The SST6-5000 c ombines short start-up times with
highest efficiency and world class operating reliability.
It consists of acombined high-pressure/medium-pressure
section and adouble-flow intermediate-pressure section
available intwo variants: high level (exhaust flowdownwards) and low level (exhaust flow on one or two sides).
Thanks to its modular design, the SST6-5000 is as flexible
as your project requires, and can be adapted to meet your
project specific thermal cycle needs.The modular turbine
design minimizes assembly and commissioning costs as
well as technical and commercial project risks. Due to the
customized design ofthe blade path, the SST6-5000 can
offer you a range of power outputs from 120 to 700 MW
depending on application and grid frequency. Our optimized condensers complete the turbo set scope of supply.
10

SST6-5000
your benefits at a glance
Maximized energy efficiency: short start-up times, high
component efficiency, advanced blading technology,
3DV profiles, variable reaction type blading
Compact and cost-effective plant layout: small footprint,
single bearing between t urbine modules
High versatility and reliability: proven designs for single
and multi shaft combined c ycle configurations
Short project lead times: s tandardized auxiliary modules
and short delivery, installation, and commissioning times
Reduced maintenance costs and high availability:
ten-year major inspection intervals

The SGen6-1000A:
the reliable power package
High power density in minimal space: the SGen6-1000A
manages a power range up to 310 MVA. Its compact
design makes our generator the first choice for gas,
combined cycle, combined heat and power, and steam
power plants. With theSGen-1000A series, we offer
you atechnology with aproven track record, with over
100machines successfully inoperation throughout the
world.
Reliable peak performance
With a world class efficiency, the SGen6-1000A ranks
among thebest inclass, and it is versatile, too. Depending
on the project requirements, we can offer you a choice
of TEWAC (Totally Enclosed Water-to-Air Cooling) or
OAC (Open Air Cooling) cooling systems. The air cooled
SGen6-1000A eliminates the maintenance and safety
related costs associated with hydrogen cooling.

SGen6-1000A
your benefits at a glance
High power output: world class efficiency
Low maintenance costs: reliable air-cooling system
Low lifecycle costs: suitable for outdoor installation,
small footprint, high efficiency
Short project lead times: dimensions appropriate for
rail transport in most countries, simplified installation
High availability and reliability: design based on
field-proven components

11

Auxiliaries the ideal equipment


to round out the package
We pay attention to the details. We not only offer
you the core c omponents for flexible and efficient
packages, we also provide the auxiliaries necessary
for economical and reliable operation. To minimize
field work during assembly and maintenance, the
auxiliary systems and associated piping are designed
and manufactured to allow easy access and require
fewer connections.
Air intake system
Ambient air is guided and filtered to the
compressor inlet with an option for a selfcleaning (pulse) filter with automatic dust
removal. Inlet air conditioning options are
available that include evaporative cooling
and inlet chilling for increased output on
hot days. Inlet heating options are available for extreme cold environments.
12

Exhaust gas system


Exhaust gas is guided from the gas turbine
via the diffuser to the turbine plants stack
or to a combined cycle plants heat recovery
steam generator (HRSG). A bypass stack
option is available for combined cycle
plants for switching between combined
cycle mode and simple cycle mode during
operation.

Electrical system
The electrical package contains equipment necessary
for sequencing, control, and monitoring of the gas turbine
and generator. This includes the gas turbine control system,
motor control centers, generator protective relay panels,
fire protection system, battery bank, battery charger,
and dry-type transformers.

During start-up, the turning gear rotates the rotor to


remove bow and facilitate a smooth start. The turning
gear also provides the breakaway torque to accelerate
the gas turbine to the speed needed to engage the SFC.
The SFC accelerates the gas turbine to ignition speed, and
after successful ignition the SFC will assist in accelerating
the unit to rated speed.

Oil systems
The oil systems consist of a lube oil (LO) package and a
hydraulic oil power unit (HPU). The LO package provides
clean, filtered oil for lubricating and lifting the gas turbine
and generator bearings, and provides lubrication for the
turning gear. The LO skid consists of the lube oil reservoir,
LO pump, and lift oil pumps and provides a support structure for the LO cooling system (fin-fan air or water cooled).
An all-weatherproof lube oil enclosure option is available
for cold or dusty environments. The HPU provides mediumpressure hydraulic oil to operate the gas fuel stage throttle
valve, the inlet guide vane actuator, and the variable guide
vane actuators.

Compressor water wash skid


The compressor water wash skid is provided for online
and offline compressor cleaning. It features an AC motordriven pump, piping, valves, strainer junction box, cabling,
flowmeter, and detergent storage tank. Everything is
assembled on a portable skid for greater flexibility.

Starting system
The starting system consists of an air cooled static frequency converter (SFC) and a turning gear system. The
turning gear can be remotely and automatically operated.
The turning gear system rotates the rotor at 120 rpm
during shutdown to facilitate a uniform cooldown.

Enclosures
The gas turbine is housed in an enclosure with easy
disassemble/assemble walls for quick engine access.
Fire protection
The fire protection system gives a visual indication of
actuation at the local control panel. The fire suppressant
system provides total protection of the turbine enclosure
and the electrical control package.
There are many other options available to meet your
project specific needs.

13

The SGT6-PAC 5000F packages on site:


tailor-made success, satisfied customers
The many different options available for customizing
the SGT6-PAC 5000F technology enable you to meet
your customers specific requirements. On the following
page, we can only offer a brief overview of the extensive
range of possible applications of the SGT6-PAC 5000F
packages. Please get in touch with us if you would like
to find out how you can use our packages profitably for
your next project.

14

References all over the world: selected


SGT6-PAC 5000F package projects in brief
Site: Posco
Country:
South Korea
Customer:
Posco Power
Plant type:
CCPP MS 2x1
Commercial operation: 2011
Fuel:
Natural gas
Power output:
633 MW*
Site:
Kemper County
Country: U.S.
Customer:
Mississippi Power Company

(a Southern Company)
Plant type: IGCC
Commercial operation: Planned for 2014
Fuel:
Syngas/natural gas
Power output:
232 MW*
Site:
Elk River
Country: U.S.
Customer:
Great River Energy
Plant type: SCPP
Commercial operation: 2009
Fuel:
Natural gas/distillate oil
Power output:
204 MW*
*Net values, corrected to ISO conditions

Genuine top performance:


Elk River Plant
Since July 2009, Great River Energy (GRE) in Minnesota
(U.S.) has placed its trust in our package technology.
GRE successfully operates a SGT6-PAC 5000F package
tasked with managing peak loads at its Elk River simple
cycle gas turbine power plant.
Great River Energy specifically opted for our SGT6-PAC
5000F package because a significant proportion of their
power supply is p
rovided by wind power. The gas turbine
is deployed as a powerful and flexible peaker to handle
power peaks regardless of weather conditions. This is an
ideal area of application: because of its fast start-up time,
the SGT6-5000F can compensate for power shortfalls in
an extremely short time, and so it plays an invaluable
role in providing a reliable and stable power supply.

Elk River Plant impressive features


SGT6-PAC 5000F generating equipment: SGT6-5000F
(204 MW), 275 MVA 60 Hz SGen6-1000A generator
38.0 percent simple cycle efficiency
Outstanding quick start capabilities:
150 MW ten minutes after the start button is pushed;
full 204 MW ISO base load output after just two to three
more minutes
Low NOx emissions: less than nine ppm dry combustion
of natural gas

15

Conclusive figures
SGT6-5000F

SGen6-1000A

Compressor

Frequency

60 Hz

Type

Axial flow

Power factor

0.8 to 0.9

Number of stages

13

Speed

3,600 rpm

Rotor speed

3,600 rpm

Terminal voltage

13.8 kV to 18 kV

Inlet guide vanes

Variable

Efficiency

Up to 98.8%

Combustion system

Apparent power

165 MVA to 310 MVA

Combustors

Coolant

Air, OAC (Open Air Cooling) or TEWAC


(Totally Enclosed Water-to-Air Cooling)

Design

In accordance with IEC and ANSI standards

Thermal classification

Class F insulation system

Type of enclosure

Suitable for outdoor installation

Excitation

Static or brushless

Transport dimensions

Suitable for rail transport in most countries

Type

Dry low NOx

Configuration

Can-annular

Number

16

Fuel

Gas fuel only


Gas fuel and liquid (dual fuel option)
Syngas (option)

Turbine
Number of stages

Drive

Cold end, direct coupled

Starting system

SST6-5000
Turbine series

Combined high-pressure/
intermediate-pressure
reverse-flow (HI) modules and
low-pressure (L) modules for 60 Hz

Starting system

SFC (Static Frequency Converter)

Starting time to base load*

30 min (base)

Turning gear speed

120 rpm

Recommended inspection intervals

Plant type

Combined cycle power plant


Coal-fired steam power plant

NOTE: flexible service intervals are available with an


LTSA (Long Term Service Agreement)

Output range

120 MW to 500 MW for combined cycle


applications

Inspection type gas fuel

Equivalent base hours Equivalent starts

Combustor

12,500

900

Hot gas path

25,000

900

50,000

1,800

120 to 700 MW for steam power plants


Main steam
(Typical parameters)

Temperature:
Pressure:

up to 600 C / 1,112 F
up to 177 bar / 2,566 psi

Major overhaul

Reheat steam
(Typical parameters)

Temperature:

up to 600 C / 1,112 F

*A fast start option is available to provide 150 MW in 10 minutes

Exhaust areas

60 Hz: 4.4 m to 8.7 m;


26 inches to 38 inches*

* Last blade profile length

16

SGT6-PAC 5000F

ISO conditions, net values


Configuration flexibility to meet power plant-specific needs
Power output

[MW]

242

Efficiency [%]

39

Heat rate

[kJ/kWh]

9,231

Heat rate

[Btu/kWh]

8,749

Pressure ratio

18.9

Exhaust temperature

[C]

~593

Exhaust temperature

[F]

~1,100

Exhaust mass flow

[kg/s]

571

Exhaust mass flow

[lb/s]

1,260

SGT6-PAC 5000F MS 2x1

ISO conditions, net values


Configuration flexibility to meet power plant-specific needs
Power output

[MW]

720

Efficiency [%]

58

Heat rate

[kJ/kWh]

6,205

Heat rate

[Btu/kWh]

5,882

[C]

~ 593

[F]

~1,100

Exhaust temperature
Exhaust temperature
Exhaust mass flow

[kg/s]

571

Exhaust mass flow

[lb/s]

1,260

17

Published by and copyright 2015:


Siemens AG
Freyeslebenstrasse 1
91058 Erlangen, Germany

Siemens Energy, Inc.


4400 Alafaya Trail
Orlando, FL 32826-2399, USA

For more information, please contact


our Customer Support Center.
Phone: +49 180/524 70 00
Fax: +49 180/524 24 71
(Charges depending on provider)
E-mail: support.energy@siemens.com

Power and Gas Division


Article No. E50001-W220-A112-V4-4A00 | Printed in Germany |
Dispo 34802 |
TH 214-150247 | W | WS | 04150.5

Printed on elementary chlorine-free bleached paper.


All rights reserved.
Trademarks mentioned in this document
are the property of Siemens AG, its affiliates,
or their respective owners.

Subject to change without prior notice.


The information in this document contains general
descriptions of the technical options available, which
may not apply in all cases. The required technical
options should therefore be specified in the contract.

You might also like