You are on page 1of 284

Facilities Management Handbook

Section 12 - Reference Materials

Policy Handbook - Release 2


August 31, 2012

2012 City of Los Angeles. All rights reserved.

Facilities
s Management Handbook

ELEC
CTRONIC FORMS
F
AN
ND REFER
RENCE
MATERIAL
M
LS

Page:
Date:

12
2-2
8/31/12
08

SEC
CTION 12A ELECT
TRONIC FORMS
F
This section
s
contaiins electronic forms neede
ed to perform the facilities m
managementt procedures d
detailed
in this
s handbook.
The fo
orms include:

NOTE: Forms are in pdf editable format.


For Excel versions of forms please contact us via
email at FM-Unit@lawa.org

12A.1 Fac
cility Change
e Documentt
12A.2 Space Naming
g Procedure Checklist
12A.3 Building System
m Scorecard
d
m Scorecard
d (BSS) Calcculation Form
m (Excel file required for calculations.)
12A.4 Building System
cility Condition Assessm
ment (FCA) D
Data Collection and Proccessing Form
m
12A.5 Fac
12A.6 Fac
cility Fixed Asset
A
Capita
alization (FFA
AC) Append
dix Form (Excel file required for calculations.)
12A.7 E-F
Form for F/S
S/C Transitio
on *This form only available in electronic format.
12A.8 Info
ormation Technology (IT
T) Change A
Assessment Form

SEC
CTION 12B REFER
RENCE MATERIAL
L
This section
s
contaiins reference materials callled out in oth
her section.
The materials
m
inclu
ude:

12B.1 Data Dictionary


y
STM UNIFOR
RMAT II Clas
ssification fo
or Building E
Elements
12B.2 AS
12B.3 PC
CR Template
e (Pdf only provides Outline for Document. Contact us for Word file.)
12B.4 Ass
sessment Guide for Builldings
12B.5 Ass
sessment Guide for Maintained Lan
ndscape
12B.6 As
ssessment Guide
G
for Lan
ndside Signss
12B.7 Ass
sessment Guide for Lan
ndside Lighti ng
12B.8 Ass
sessment Guide for Lan
ndside Pavem
ment

2
2012 City of Los A
Angeles. All righ
hts reserved.

2012 City of Los Angeles. All rights reserved.

FACILITY CHANGE DOCUMENT


Unique
ID

Location / Area
/ Facility

Brief Description of F/S/C


being changed

Replacement?
Y/N

Yes

New
Unique ID if
replaced

Date F/S/C
Modified

Reason for Modification /


Change.

Attributes
Attached
Y/N

Yes

Facility
Registry
Updated
Y/N

Yes

2012 City of Los Angeles. All rights reserved.

Building Space Naming Procedure Checklist


Building ID:

Description:

Building Name:

Building Address:

Requested by:

Naming Authorized by:

Naming Objective(s):
Existing Space

Facilities Management Coordinator:


New or Remodeled Space
Naming Performed by:
Establish Column Name
Reviewer List:

Procedure Checks

Yes

No

NA

1. For existing building and acquisition process, have the floor plans for subject areas been processed into the
LAWA Geospatial System (GIS)?
1.1. If No, Initiate a request to have the GIS database updated
2. For existing building and acquisition process, are the most recent floor plans available in CADD or another
suitable electronic format?
2.1. If No, stop the evaluation and coordinate with requestor to develop a plan to get floor plans processed
into a format suitable for the naming process
3. Has Facilities Management coordinator reviewed and approved floor plans and is there stakeholder
consensus regarding designation of zones and/or levels?

4. Completed corridor layout review and acceptance?

5.

Completed space name review and acceptance?

6.

Completed review and acceptance complete?

7.

Completed space walk-through validation of naming results?

8.

Final naming review and documentation complete and submitted to FMS and GIS data team.

2012 City of Los Angeles. All rights reserved.

Bu
uildin
ng Syste
S em S
Scorrecarrd
Grad
ding Sta
andard
ds for Non-Tec
N
chnicall Assesssment oof
Build
ding Sy
ystems

R
Release 2.0 Au
ugust, 2012

2012 City of Los Angeles. All rights reserved.

BUILDIN
NG SCORE C
CARD

Bu
uilding Name
e and FMS_
_ID:
Bu
uilding Addre
ess:
Bu
uilding Type

_____
___________
__________
___

___
___________
__________
_____

_______
__________
___________
_

Bu
uilding Mana
ager

___
___________
__________
_____

LA
AWA Propertty Manager

_______
__________
__________
__

Ev
valuation perrformed by:

_______
__________
__________
__

valuation Date:
Ev

___
___________
__________
_____

Foundation
n (page 2), Super
S
Structture (page 2), and Exterrior Vertical
Enclosures
s (page 3), Exterior
E
Hori zontal Enclo
osures (page
e 4)

Interior Con
nstruction (p
page 5), Inte rior Finishess (page 6)

Conveying System (page 7)

Plumbing (p
page 8), HV
VAC (pages 9
9, 10)

Fire Protec
ction (page 11)

Electrical (p
pages 12, 13
3)

Electronic Safety
S
and Security
S
(pag
ge 14)

Site Improv
vements (pages 15, 16)

2012 City of Los Angeles. All rights reserved.

General Information and Field Notes:


_____________________________________________________________________________________
_____________________________________________________________________________________
_____________________________________________________________________________________
_____________________________________________________________________________________
_____________________________________________________________________________________
_____________________________________________________________________________________
_____________________________________________________________________________________
_____________________________________________________________________________________
_____________________________________________________________________________________
_____________________________________________________________________________________
_____________________________________________________________________________________
_____________________________________________________________________________________
_____________________________________________________________________________________
_____________________________________________________________________________________
_____________________________________________________________________________________
_____________________________________________________________________________________
_____________________________________________________________________________________
_____________________________________________________________________________________
_____________________________________________________________________________________
_____________________________________________________________________________________
_____________________________________________________________________________________
_____________________________________________________________________________________
_____________________________________________________________________________________
_____________________________________________________________________________________
_____________________________________________________________________________________
_____________________________________________________________________________________
_____________________________________________________________________________________
_____________________________________________________________________________________

2012 City of Los Angeles. All rights reserved.

SYSTEM:
nt:
Componen

A10 Fo
oundations
A1010 Standard Foundations

RATING

EVALUATION

CONDITION STANDA
ARD

10

Excellent Condition

New or like new with n


no defects. No visible signs of settlement or
on elements, including footting, walls and
d
cracking.. All foundatio
slabs sho
ow no sign off distress.

7.5

ndition
Good Con

Minor vis
sual cracking or spalling. C
Cracking in wa
alls or slabs iss
superficia
al. Slabs and footing are le
evel and wallss and column
ns are
plumb.

Average Condition
C

Cracking
g and/or leakin
ng evident, bu
ut no serious structural deffects.
Minor diff
fferential settle
ement and slab settlement only in locallized
areas.

2.5

Poor Con
ndition

Excessiv
ve or uneven ssettlement. C
Cracking visible through
foundatio
on walls. Sign
nificant differe
ential settleme
ent between ccolumn
footings affecting
a
the sstructural inte
egrity of the b
building. Steel
reinforcin
ng is exposed
d in some loca
ations.

Fail Cond
dition

Foundation is no long er structurallyy sound.

s: ___________
____________
_____________
______________________________________________
Comments
__________
____________
_____________
____________
______________________________________________

SYSTEM:
nt:
Componen

B10 Su
uperstructure
e
B1010 Floor Constru
uction (include
es loading do
ocks/ramps)
B1080 Stairs

RATING

EVALUATION

CONDITION STANDA
ARD

10

Excellent Condition

New or like new. No vvisible signs o


of distress to sstructure or
finishes.

7.5

Good Con
ndition

Stairs/ram
mps in norma
al working con
ndition. No se
ettling, damag
ge, or
other visiible signs of d
distress to strructural framin
ng. Finishes sslightly
worn but no major defficiencies obsserved.

Average Condition
C

Visible wear
w
to stair trreads, risers, landing, and ramps that ca
an be
easily rep
paired. Stairss are structura
ally sound. Miinor cracking or
settling may
m be observved, which ca
an be easily rrepaired. Minimal
rust and//or deterioratio
on to structurral piers and b
beams.

2.5

Poor Con
ndition

Major strructural deficie


encies, settlin
ng and cracking observed in
floor structure. Structu
ural piers and
d beams exhib
bit significant
uire complete replacementt, and
rusting/damage. Stair finishes requ
age is observe
ed to stairs an
nd/or ramps.
minor strructural dama

Fail Cond
dition

Stair or ramp finishes require comp


plete replacem
ment. Stairs o
or
nd present a safety hazard
d.
ramps arre not structurrally-sound an
Substanttial distressess to floor struccture are obse
erved.

s: ___________
____________
_____________
______________________________________________
Comments
__________
____________
_____________
____________
______________________________________________

2
2012 City of Los Angeles. All rights reserved.

SYSTEM:
nt:
Componen

B20 Exterio
or Vertical En
nclosures
B2010 Exterrior Walls

RATING

EVALUATION

CONDITION STANDA
ARD

10

Excellent Condition

New or like new with n


no defects. No signs of wa
ater intrusion o
or
elated crackin
ng.
damage. No signs of sstructurally-re

7.5

Good Con
ndition

Exterior wall
w system in
n sound cond
dition. Minor ccracking in wa
all
treatmen
nt may be obsserved, which can be easilyy repaired. N
No sign
of water intrusion or d amage.

Average Condition
C

Visible se
ettlement of sstructural mem
mbers, wall trreatment show
wing
signs of settlement.
s
A
Any water intru
usion is incon
nsequential.

2.5

Poor Con
ndition

Settleme
ent is continuo
ous, significan
nt cracking is apparent. W
Water
intrusion is apparent w
with signs of w
water entrancce into buildin
ng and
ation and/or le
evel changes in
penetration into other areas. Eleva
al members a
are directly ob
bservable.
horizonta

Fail Cond
dition

Failure of wall structurre. Building s eems unsafe

s: ___________
____________
_____________
______________________________________________
Comments
__________
____________
_____________
____________
______________________________________________

SYSTEM:
nt:
Componen

B20 Exterio
or Vertical En
nclosures
B2020 Exterrior Windows
B2050 Exterrior Doors (inc
cludes overhe
ead doors)

RATING

ON
EVALUATIO

CONDITION
C
S
STANDARD

10

Excellent Co
ondition

New
N
or like ne
ew with no de
efects. Windo
ows or doors a
are
completely
c
fun
nctional and m
meet requirem
ments.

7.5

Good Condition

Windows
W
and doors have b
been maintain
ned well and are in
good
g
operatin
ng condition. O
Only minor ro
outine mainten
nance
required.
r

Average Condition

Some
S
cracked
d window pan
nes are obserrved, door
hardware
h
mayy require repa
air or adjustm
ment. All deficiiencies
can
c be easily repaired.

2.5

Poor Condition

Windows
W
or d
doors inadequ
uate for intend
ded function.

Fail Conditio
on

Windows
W
and doors are no
ot existent or provide little tto no
protection
p
from
m outside ele
ements. Do no
ot meet life sa
afety
codes
c
and un able to securre facility. Building is unsaffe and
a clear dange
er to occupantts.

s: ___________
____________
_____________
______________________________________________
Comments
__________
____________
_____________
____________
______________________________________________

3
2012 City of Los Angeles. All rights reserved.

SYSTEM:
nt:
Componen

B30 Exterio
or Horizontal Enclosures
B3010 Roofing
ces
B3020 Roof Appurtenanc

RATING

ATION
EVALUA

CONDITION STANDA
ARD

10

Excellen
nt Condition

New or like new with n


no defects. P
Pitch line straiight, no sign o
of
a ridge line, w
with good dra
ainage and no
o ponding. No
o
sagging at
plugged roof drains orr flashing failu
ures.

7.5

Good Co
ondition

Minor me
embrane craccking on surfa
ace with no le
eakage. Sligh
ht
sagging in
i ridge line, m
minor signs o
of ponding. R
Roof drains plu
ugged
with grav
vel or leaves. Any deficienccies can be e
easily repaired
d.

Average
e Condition

Visible crracking or blissters in surfacce sealing witth no leakage


e.
Sagging at ridge line, ponding or sttanding waterr puddles, loo
ose or
d flashing. So
ome isolated roof drain clo
ogs. Minor rep
pairs
displaced
required.

2.5

Poor Condition

Serious cracking
c
and//or blisters in surface sealing with visible
e
leakage through
t
roof. Sagging and
d irregular ridg
ge line, ponding and
standing bodies of wa
ater. Damage or debris-clogged roof dra
ains
g are apparen
nt. Spongy or water-soaked
d
and damaged flashing
m
with
h water damag
ge to underlying structure.
surface materials

Fail Cond
dition

Roof doe
es not preventt rain or moissture entry. B
Broken ridge o
or
rafters. Roofing
R
mate
erials are wate
er logged and
d collapsing. T
Total
roof repla
acement requ
uired.

s: ___________
____________
_____________
______________________________________________
Comments
__________
____________
_____________
____________
______________________________________________

4
2012 City of Los Angeles. All rights reserved.

SYSTEM:
nt:
Componen

C10 Interiorr Constructio


on
C1010 Interiior Partitions

RATING

EVALUA
ATION

CONDITION STANDA
ARD

10

Excellen
nt Condition

New or like new with n


no defects.

7.5

Good Co
ondition

Interior partitions
p
are iin normal worrking order. W
Walls are
structurally sound. De
eficiencies are
e minor and e
easily repaired
d.

Average
e Condition

Slightly soiled,
s
worn o
or cracked surrfaces that require minor re
epairs.
Deteriora
ation such as peeling/fadin
ng/stains/craccking are mino
or and
affect only a small porrtion of interio
or partitions. W
Walls are
structurally sound.

2.5

Poor Condition

Soiled orr stained wall surfaces, cra


acking, eviden
nce of water
intrusion. Plaster requ
uires repair. In
nterior partitio
ons have strucctural
hat could resu
ult in hazardo
ous conditionss to building
defects th
occupantts if not corre cted immedia
ately.

Fail Condition

Interior partitions
p
have
e deteriorated
d to conditionss that result in
n an
eminent life safety hazzard to buildin
ng occupantss.

s: ___________
____________
_____________
______________________________________________
Comments
__________
____________
_____________
____________
______________________________________________

SYSTEM:
nt:
Componen

C10 Interiorr Constructio


on
C1020 Interiior Windows
C1030 Interiior Doors

RATING

EVALUATIO
ON

CONDITION
C
S
STANDARD

10

Excellent Co
ondition

New
N
or like ne
ew with no de
efects.

7.5

Good Condition

Interior doors and windowss are in good working orde


er.
Doors
D
are hun
ng plumb. Trim is set plum
mb and level w
with
jo
oints tightly fi tted. Hardware may requirre minor
readjustment.
r
. Any deficien
ncies are mino
or and can be
e
easily
e
repaired
d.

Average Condition

Minor
M
blemish
hes, including
g damaged fra
ame, chipped paint,
broken
b
or mallfunctioning h
hardware that can be easilyy
repaired.
r
Dam
mage affects o
only a small p
portion of tota
al
interior window
ws and doorss.

Poor Condition

Major
M
repairs//replacement required for m
more than ha
alf of
interior doors and windowss. Damaged fframes, broke
en
panes,
p
malfun
nctioning hard
dware and oth
her significant
deficiencies
d
a
are apparent.

on
Fail Conditio

Interior doors and windowss have deterio


orated to cond
ditions
that
t
result in a
an eminent liffe safety haza
ard to building
g
occupants.
o
Co
omplete repla
acement requ
uired.

s: ___________
____________
_____________
______________________________________________
Comments
__________
____________
_____________
____________
______________________________________________

5
2012 City of Los Angeles. All rights reserved.

SYSTEM:
Componen
nt:

C20 Interiorr Finishes


C2010 Wall Finishes
C2030 Floorring
C2050 Ceilin
ng Finishes

RATING

EVALUATIO
ON

CONDITION
C
S
STANDARD

10

Excellent Co
ondition

New
N
or like ne
ew with no de
efects. Surfacce finishes ha
ave no
blemishes.
b
Ma
aterial is clea
an and in good
d condition. F
Floor
surfaces
s
are fflat and level.

7.5

Good Condition

Interior finishe
es are in good
d working ord
der. Finish ma
aterial
s clean and in
n good condittion with only minor wear
is
apparent.
a
Anyy deficienciess affect only a small portion
n of
finishes
f
and rrequire minor repairs only.

Average Condition

Slight
S
deteriorration of finish
hes, soiled, w
worn, or crackked
surfaces
s
begi nning to appe
ear. Signs of w
wear apparen
nt,
carpets
c
have tears or stain
ns, tiles are worn or chippe
ed.
Less
L
than halff of finish matterial requiress replacemen
nt.

Poor Condition

Significant
S
po
ortion of finish material at e
end of service
e life
and
a replacem
ment and renewal should be
e scheduled. Badly
soiled
s
or stain
ned surfaces, cracking evid
dent. Cracking or
spalling
s
of con
ncrete floor surfaces. Majo
ority of lay-in cceiling
tiles
t
loose or m
missing.

on
Fail Conditio

Floor
F
and ceil ing surfaces have deteriorrated to conditions
that
t
result in e
eminent dang
ger to human safety. Floorr is not
structurally
s
so
ound. Hazard
dous condition
ns, including friable
asbestos,
a
nee
ed immediate attention. Ca
arpets soiled tto
unsightly
u
cond
dition. Floor tile is broken o
or chipped. Fallen
plaster
p
or sevverely impaire
ed surfaces. C
Conditions ressulting
in damage to substrate and
d surface.

s: ___________
____________
_____________
______________________________________________
Comments
__________
____________
_____________
____________
______________________________________________

6
2012 City of Los Angeles. All rights reserved.

SYSTEM:
Componen
nt:

D10 Convey
ying
D1010 Vertic
cal Conveying
g Systems (e
elevators and escalators)
D1030 Horiz
zontal Convey
ying (moving walks)

RATING

ON
EVALUATIO

CONDITION
C
S
STANDARD

10

Excellent Co
ondition

New
N
or like ne
ew with no ob
bservable deffects. State/lo
ocal
inspection cerrtifies that all components are in working
condition.
c

7.5

Good Condition

State/local
S
insspection certiffies that all co
omponents arre in
normal
n
workin
ng condition. No evidence
e of malfunctio
on or
imminent dec line in perform
mance. Minorr finish defectts
appearing
a
on surfaces, wh
hich can easilyy be repaired.
Surfaces
S
are fflat and level,, cab travel iss smooth and levels
properly.
p
All m
major equipme
ent is operating normally w
with
only
o
minor russting, noise, o
or vibration.

Average Condition

State/local
S
insspection requ
uires some minor items to b
be
repaired.
r
Systtem continuess to perform w
within accepta
able
standards,
s
witth some incre
ease in down time. Deterio
oration
of
o finishes, so
oiled, worn, orr cracked surffaces beginniing to
appear.
a
Som e finish material should be
e replaced. Rusting
and
a leaks are
e apparent, bu
ut can be easily repaired.
Equipment
E
is nearing end o
of useful life.

2.5

Poor Condition

State/local
S
insspections require frequent and/or majorr
systems
s
repa irs. Major com
mponents are
e not functioniing
and
a should be
e replaced. Surfaces are n
not flat or leve
el,
significant
s
we
ear to finishes . Down-time iis high regard
dless
of
o use. Majorrity of equipm
ment is beyond
d useful life and
requires
r
repla
acement. Majo
or repairs are
e required to rrestore
system
s
to ope
erating condittion.

on
Fail Conditio

State/local
S
insspection recommends repllacement or
decertification
d
n. System at e
end of its use
eful life and ca
annot
feasibly
f
be resstored to accceptable stand
dards. Down-time
and/or
a
repair ffrequency is high and/or p
parts are difficcult to
obtain.
o

s: ___________
____________
_____________
______________________________________________
Comments
__________
____________
_____________
____________
______________________________________________

7
2012 City of Los Angeles. All rights reserved.

SYSTEM:
Componen
nt:

D20 Plumbiing
D2010 Domestic Water Distribution
D
(D
D2010.40 Dom
mestic Water Piping)

RATING

EVALU
UATION

CONDITION STANDA
ARD

10

Excellent Condition

Plumbing
g supply syste
em is new or like new and in normal
operating
g condition.

7.5

Good Condition
C

Plumbing
g system com
mpletely opera
ational. Any deficiencies
including
g leaking partss or rust are m
minor and affe
ect only a sm
mall
portion of the system. Sound/vibrattion controls a
and sufficientt shutoff valves
s exist. No lo
oss of redund ancy and ade
equate for futu
ure
loads.

Average Condition

System is in working o
order but minor repairs are
e required. Vissible
deficienc
cies include m
missing insulattion, minor leaks and rust,
mineral deposits
d
or ino
operable bacckflow preventtion.

2.5

ondition
Poor Co

Major rep
pairs required
d. Operations are inefficien
nt, frequent le
eaks
are appa
arent or signifiicant rust/corrrosion or no b
backflow prevvention

Fail Condition

System inoperable or requires com


mplete replace
ement.

s: ___________
____________
_____________
______________________________________________
Comments
__________
____________
_____________
____________
______________________________________________

SYSTEM:
Componen
nt:

D20 Plumbiing
D2010 Domestic Water Distribution
D
(D
D2010.60 Plum
mbing Fixture
es)

RATING

EVALU
UATION

CONDITION STANDA
ARD

10

Excellent Condition

New or like new with n


no defects.

7.5

Good Condition
C

Plumbing
g fixtures com
mpletely opera
ational with on
nly minor leakking
parts and
d rust. Any de
eficiencies afffect a small po
ortion of fixtures
and can be easily corrrected.

Average Condition

Fixtures are in working


g order but m
minor repairs a
are required.
Missing insulation, min
nor leaks and
d rust, minera
al deposits, no
o
w prevention, b
broken/inoperrable fixtures may be obse
erved,
backflow
deficienc
cies can be ea
asily corrected
d.

2.5

ondition
Poor Co

Significan
nt number of fixtures need
d to be repaire
ed or replaced
d.
Problems
s result in freq
quent leaks o
or significant rrust/corrosion
n.

Fail Condition

Most fixtu
ures are inop erable and re
equire comple
ete replaceme
ent.

s: ___________
____________
_____________
______________________________________________
Comments
__________
____________
_____________
____________
______________________________________________

8
2012 City of Los Angeles. All rights reserved.

SYSTEM:
Componen
nt:

D20 Plumbiing
D2020 Sanittary Drainage
e

RATING

UATION
EVALU

CONDITION STANDA
ARD

10

Excellent Condition

Plumbing
g waste syste
em is new or like new and in normal ope
erating
condition
n.

7.5

Good Condition
C

Plumbing
g waste syste
em is in norma
al working ord
der and requires
only routine maintena nce. No leakiing parts, rustt, corrosion. S
Sound
ation controls exist. Sufficie
ent clean-outss exist. Sump
p
and vibra
pumps are automatic where necesssary.

Average Condition

System is in working o
order but minor repairs are
e required. Vissible
deficienc
cies include m
missing insulattion, minor leaks and rust,
mineral deposits,
d
no b
backflow prevvention, broke
en/inoperable
fixtures, inoperative
i
su
ump pumps, insufficient clean-outs.

2.5

ondition
Poor Co

Major rep
pairs required
d to bring systtem to good o
operating con
ndition.
Operations are inefficiient, frequentt leaks are ap
pparent, signifficant
osion causing
g damage to o
other building
g systems, no
rust/corro
backflow
w prevention, iinsufficient cle
ean-outs.

Fail Condition

System is inoperable or requires co


omplete repla
acement.

s: ___________
____________
_____________
______________________________________________
Comments
__________
____________
_____________
____________
______________________________________________

SYSTEM:
nt:
Componen

D30 HVAC
D3020 Heating Systems

RATING

EVALU
UATION

CONDITION STANDA
ARD

10

Excellent Condition

New or like new with n


no defects.

7.5

Good Condition
C

Equipme
ent and piping
g in normal wo
orking condition. Automaticc
controls in
i working ord
der and sound and vibratio
on controls arre
installed. Any deficien
ncies are mino
or and can be
e easily repairred.

Average Condition

System is in working b
but needs som
me repair. Th
here are minor
st, unusual no
oise or missin
ng insulation. Equipment iis
leaks, rus
nearing end
e of useful life.

2.5

ondition
Poor Co

Major rep
pairs are requ
uired. Significcant leaks, missing insulattion,
inefficien
nt operation, e
excessive noise or frequen
nt breakdownss
reported.. Majority of e
equipment see
ems to need to be replace
ed.

Fail Condition

System is completely inoperable.

s: ___________
____________
_____________
______________________________________________
Comments
__________
____________
_____________
____________
______________________________________________

9
2012 City of Los Angeles. All rights reserved.

SYSTEM:
nt:
Componen

D30 HVAC
D3030 Cooling Systems

RATING

EVALU
UATION

CONDITION STANDA
ARD

10

Excellent Condition

New or like new with n


no defects.

7.5

Good Condition
C

Equipme
ent and piping
g in normal wo
orking condition. Automaticc
controls in
i working ord
der and sound and vibratio
on controls arre
installed. Any deficien
ncies are mino
or and can be
e easily repairred.

Average Condition

System is in working o
order but requ
uires minor m
maintenance. T
There
oise or missin
ng insulation.
are minor leaks, rust, noticeable no
ent is nearing end of usefull life.
Equipme

2.5

ondition
Poor Co

Major rep
pairs are requ
uired. There a
are significantt leaks, missin
ng
insulation
n, inefficient o
operation, exccessive noise
e or frequent
breakdow
wns reported.. Majority of e
equipment is p
past the end o
of
useful life
e and require s replacemen
nt.

Fail Condition

System is completely inoperable.

s: ___________
____________
_____________
______________________________________________
Comments
__________
____________
_____________
____________
______________________________________________

SYSTEM:
nt:
Componen

D30 HVAC
C Distribution
n Systems (hyydronic, steam
m, air distribu
ution)
D3050 HVAC
D3060 Ventilation

RATING

UATION
EVALU

CONDITION STANDA
ARD

10

Excellent Condition

Equipme
ent and piping
g is new or like
e new and op
perating prope
erly.

7.5

Good Condition
C

Equipme
ent and piping
g in normal wo
orking condition. Automaticc
controls in
i working ord
der and sound and vibratio
on controls arre
installed. Insulation is in place and little to no russt or corrosion
observed
d. System is b
balanced, no excessive no
oise.

Average Condition

The syste
em is in workking order but requires minor maintenan
nce.
Minor lea
aks, rust, exce
essive noise, missing insulation.

2.5

Poor Co
ondition

Major rep
pairs are requ
uired to bring system to go
ood operating
condition
n. Significant leaks, missin
ng insulation, inefficient
operation
n, frequent brreakdowns reported.

System is inoperative or requires re


eplacement o
of more than 8
85% of
c
system components.
s: ___________
____________
_____________
______________________________________________
Comments
Fail Condition

__________
____________
_____________
____________
______________________________________________

10
2012 City of Los Angeles. All rights reserved.

SYSTEM:
nt:
Componen

D40 Fire Pro


otection
D4010 Fire Suppression
S

RATING

EVALU
UATION

CONDITION STANDA
ARD

10

Excellent Condition

New or like new fire sp


prinkler riser and system ccomponents.
on sticker possted from loca
al
Sprinklerr riser has currrent inspectio
authority//contractor.

7.5

C
Good Condition

Fire sprin
nkler system ccomponents completely op
perable. One
e or
more valv
ves may be o
obstructed, bu
ut all sprinklerrs are unobsttructed
and appe
ear to provide
e adequate co
overage throu
ughout the building.
Sprinklerr riser has currrent inspectio
on sticker possted from loca
al
authority//contractor.

Average Condition

Sprinklerrs, valves, fire


e pump, or oth
her system co
omponents ap
ppear
moderate
ely corroded, or corrosion is visible on p
painted or
galvanize
ed sprinkler p
pipe. Some s prinklers are obstructed orr
appear in
nsufficient in q
quantity in an
ny areas of the
e building. Miinor
leaks or drips
d
from the
e sprinkler sysstem may be evident from
m stains
on ceiling
gs, floors, or w
wall finishes. Control valves are fully open
but do no
ot have a cha
ain/lock or electronic tampe
er switch.

2.5

ondition
Poor Co

Sprinklerrs are only ob


bserved in the
e partial areass of the buildin
ng, are
located more
m
than 12 inches down from the ceiling/deck, or h
have
not been relocated witth new partitio
ons or buildin
ng renovationss. Wet
s
pipin
ng installed in areas of the building interrior or
system sprinkler
exterior that
t
are subje
ect to freezing
g temperature
es. No exterior
water flow
w bell or fire d
department cconnection is provided, or ffire
sprinkler water flow sw
witch wiring d
does not appe
ear connected
d to the
m panel. Jockkey pump or d
dry system air compressorr
fire alarm
running frequently
f
or ccontinuously.

Fail Condition

System is completely inoperable.

s: ___________
____________
_____________
______________________________________________
Comments
__________
____________
_____________
____________
______________________________________________

11
2012 City of Los Angeles. All rights reserved.

SYSTEM:
Componen
nt:

D50 Electric
cal
D5020 Electtrical Service and Distributtion (panelboa
ards, switchgear, etc.)
D5030 Gene
eral Purpose Electric Powe
er (ducts, cab
ble trays, wirin
ng)

RATING

EVALU
UATION

CONDITION STANDA
ARD

10

Excellent Condition

All wiring
g, cable tray a
and conduit arre new or like
e new with no
defects and
a meet cod e. Visible low
w-voltage wirin
ng is labeled,
appears neatly organiized and route
ed in straight, well-supportted
y. Conduit (fo
or power wirin
ng) routing is neat, straightt,
cable tray
organized and labeled
d. Bends are neat and orga
anized.

7.5

Good Condition
C

Wiring, cable
c
tray and
d conduit are kknown to be lless than 10 yyears
old, still neat
n
in appea
arance and prroperly labeled. Components
are fully operational
o
w
with only mino
or repairs requ
uired. Wiring is
known to
o be of adequ ate size to ca
arry the curren
nt loads. Circcuit
protection is matched to the wire siize.

Average Condition

Wiring, cable
c
tray and
d conduit are 10 to 20 yearrs old. Most la
abels
are still le
egible. Repairr and mainten
nance is done
e as needed a
and no
evidence
e of loss of po
ower to equipm
ment. Minor rrepairs require
ed to
the comp
ponents. Wiriing is known tto be of adeq
quate size to ccarry
the curre
ent loads

2.5

Poor Co
ondition

Wiring, cable
c
tray and
d conduit are 2
20-25 years o
old. Labels arre
illegible or
o missing. Diisorganized a
and/or too much wiring is ro
outed
in the cab
ble tray. Incid
dents regarding the loss of power to
equipment have occurrred. Major rrepairs or repllacement required
past
to the components. O utages have been reported during the p
n to be not of adequate sizze to carry the
e loads
year. Wiiring is known
that are on
o the circuitss.

Fail Condition

Wiring, cable
c
tray and
d conduit are g
greater than 2
25 years old.
System has
h deterioratted to a condition that mayy present life ssafety
hazards to
t building occcupants and requires com
mplete replace
ement.

s: ___________
____________
_____________
______________________________________________
Comments
__________
____________
_____________
____________
______________________________________________

12
2012 City of Los Angeles. All rights reserved.

SYSTEM:
Componen
nt:

D50 Electric
cal
D5040 Lightting

RATING

EVALU
UATION

CONDITION STANDA
ARD

10

Excellent Condition

New or like new with n


no defects. Energy efficien
nt.

7.5

Good Condition
C

System is in good worrking order with no broken fixtures or le


enses.
Lighting controls
c
are in
n good condittion. Any deficiencies are minor
and can be easily corrrected.

Average Condition

The syste
em is in workking order but requires minor maintenan
nce.
Deficienc
cies such as lloose or disco
olored coverss, diffusers an
nd
fittings; surface
s
corrossion; loose su
upports; and intermittent
operation
ns may be ob
bserved. Lightting controls a
are operationa
al but
in need of
o minor main
ntenance.

2.5

Poor Co
ondition

Major rep
pairs are requ
uired. Compo
onents are ino
operable, brokken,
corroded
d with pitting, a
abandoned in
n place, have missing partss, or
are beyond repair. Ele
ectrical code vviolations are
e noted, but are not
deemed hazardous to
o the life safetty of building occupants.

Fail Condition

System is completely inoperable an


nd/or hazardo
ous to the life
e safety
of buildin
ng occupants.. Does not me
eet minimum life safety or
electricall code regulattions.

s: ___________
____________
_____________
______________________________________________
Comments
__________
____________
_____________
____________
______________________________________________

13
2012 City of Los Angeles. All rights reserved.

SYSTEM:
Componen
nt:

D70 Electro
onic Safety and Security
D7010 Acce
ess Control an
nd Intrusion D
Detection
D7050 Detection and Ala
arm

RATING

EVALUATIO
ON

CONDITION
C
S
STANDARD

10

Excellent Co
ondition

New
N
or like ne
ew UL-labeled
d addressable fire alarm p
panel.
Panel
P
has currrent inspectio
on sticker possted from loca
al
authority/cont
a
tractor.

7.5

Good Condition

UL-labeled
U
ad
ddressable firre alarm pane
el with LCD re
eadout
in operable co
ondition. One or more horn
ns/strobes or pull
stations
s
may a
appear obstru
ucted or mounted too high
h, but
any
a smoke de
etectors appe
ear completelyy operable. P
Panel
has
h current in
nspection stickker posted fro
om local
authority/cont
a
tractor.

Average Condition

No
N UL label o
on the fire alarrm panel or p
panel is outda
ated
conventional
c
ttype with LED
Ds only (no LC
CD readout.)
Insufficient qu
uantity of strobes and horn
ns observed in
n the
occupied
o
area
as of the build
ding, no pull sstations provid
ded
near
n
exit doorrs, or smoke d
detectors app
pear dirty, covvered,
or
o obsolete. A few false allarms may be
e reported from
m
building
b
occup
pants. No sm
moke detectorr located direcctly
over
o
fire alarm
m panel.

2.5

Poor Condition

nel requires m
Fire
F alarm pan
major repairs to return to n
normal
working
w
orderr, or no fire ala
an be located. May
arm panel ca
be
b no LEDs p
provided on pa
anel. Wiring near panel orr
devices
d
appea
ars cut or frayyed. No smokke alarms or ssmoke
detectors
d
loca
ated in sleepin
ng rooms of rresidential
occupancies.
o
Panel canno
ot be reset to n
normal condittion.

Fail Conditio
on

nel was remo


Fire
F alarm pan
oved or is inop
perable.

14
2012 City of Los Angeles. All rights reserved.

SYSTEM:
Componen
nt:

G20 Site Im
mprovements
s
G2010 Road
dways
G2020 Parking Lots

RATING

EVALU
UATION

CONDITION STANDA
ARD

10

Excellent Condition

Roadway
ys and parkin
ng lots are lesss than one ye
ear old and sh
how
no visible
e signs of disttress or failurre. Preventive
e maintenancce will
be adequ
uate to mainta
ain existing co
ondition.

7.5

C
Good Condition

No visible
e signs of disstress or failurre in roadwayy or parking lo
ots.
Routine maintenance
m
will be adequ
uate to mainta
ain existing
condition
n.

Average Condition

Minor fra
actures in road
dway or parkiing lots. No disruption of service
accessing the facility. A few minor fractures in p
paving materia
al.

2.5

Poor Co
ondition

Fractures
s in paving afffecting roadw
way or parking
g lot usage.
Correctiv
ve action shou
uld take place
e at once to sstop any furthe
er
damage.

Fail Condition

Signs of failure or disttress such as cracking or sspalling. Emergency


attention required, succh as patching and possible excavation
n and
ment of roadw
way paving and base materrials.
replacem

s: ___________
____________
_____________
______________________________________________
Comments
__________
____________
_____________
____________
______________________________________________

SYSTEM:
nt:
Componen

G20 Site Im
mprovements
s
G2030 Pede
estrian Paving
g

RATING

EVALU
UATION

CONDITION STANDA
ARD

10

Excellent Condition

Sidewalk
ks and pedesttrian paving a
are less than o
one year old and
show no visible signs of distress orr failure. Prevventive
ance will be a
adequate to m
maintain existing condition.
maintena

7.5

C
Good Condition

No visible
e signs of disstress or failurre in paving. Routine
maintena
ance will be a
adequate to m
maintain existing condition.

Average Condition

Minor fra
actures and se
eparations in paving. No d
disruption of sservice
accessing the facility. A few minor fractures in p
paving materia
al.
ous observatio
on recommen
nded.
Continuo

2.5

ondition
Poor Co

Fractures
s in paving afffecting pedesstrian paveme
ent usage and
d
access to
o the facility. P
Possible unevven surfaces. Corrective a
action
should ta
ake place at o
once to stop a
any further da
amage.

Fail Condition

Paving appears to havve failed. Majjor distress su


uch as crackin
ng or
o require patcching and posssible excava
ation
spalling, that seems to
acement of pa
aving and basse.
and repla

s: ___________
____________
_____________
______________________________________________
Comments
__________
____________
_____________
____________
______________________________________________

15
2012 City of Los Angeles. All rights reserved.

SYSTEM:
Componen
nt:

G20 Site Im
mprovements
s
G2040 Site Developmentt (Fences/Gattes, Retaining
g Walls, Signss and
ures
Water Featu

RATING

EVALU
UATION

CONDITION STANDA
ARD

10

Excellent Condition

Site deve
elopment item
ms less than o
one year old w
with no visible
e signs
of distres
ss or failure. Preventive m
maintenance w
will be adequa
ate to
maintain existing cond
dition.

7.5

C
Good Condition

No visible
e signs of disstress or failurre. Routine m
maintenance w
will be
adequate
e to maintain existing cond
ditions.

Average Condition

Signs of wear apparen


nt. Soiled, wo
orn, damaged
d or cracked
surfaces or slight soili ng or discolo ration of finishes visible.

2.5

Poor Co
ondition

pparent. Rep
Major sig
gns of wear ap
placement and renewal of finish
or covering should be scheduled. S
Soiled, stained, cracked fin
nishes.
aintenance wiill restore to u
usable conditiion.
Major ma

Fail Condition

Severe distress
d
or faillure of site de
evelopment co
omponent.
Possible hazardous co
onditions present.

s: ___________
____________
_____________
______________________________________________
Comments
____________
_____________
____________
______________________________________________
__________

SYSTEM:
nt:
Componen

G40 Site Ele


ectrical Utilitties
G4010 Site Lighting

RATING

EVALU
UATION

CONDITION STANDA
ARD

10

Excellent Condition

The site lighting is les s than a yearr old, energy e


efficient, and in
on. Requires o
only preventivve maintenan
nce to
good worrking conditio
maintain existing cond
dition.

7.5

C
Good Condition

The syste
em is in good
d working orde
er, energy effficient and on
nly
requires routine mainttenance. No b
broken fixture
es or lenses.
Appropria
ate lighting le
evels. No bare
e fixtures in public areas.

Average Condition

The syste
em is in workking order but needs mainttenance.
Deficienc
cies include n
non-functionin
ng fixtures, po
oor light levelss,
unprotec
cted bulbs or iinefficient fixtu
ures.

2.5

ondition
Poor Co

System in working ord


der but has significant prob
blems. Major
ance required
d.
maintena

Fail Condition

System is inoperable and requires major repairss or replacem


ments
e condition
b
to usable
to bring back

s: ___________
____________
_____________
______________________________________________
Comments
__________
____________
_____________
____________
______________________________________________

16
2012 City of Los Angeles. All rights reserved.

EXAMPLE: For illustrative purposes Level 3 Score of 5.0 used for all fields

BuildingSystems
Assessor:

Date:

Systems
as
UniformatLevels1,2and3
ASUBSTRUCTURE
A10Foundations
A1010StandardFoundations
BSHELL
B10Superstructure
B1010FloorConstruction
B1080Stairs
B20ExteriorVerticalEnclosures
B2010ExteriorWalls
B2020ExteriorWindows
B2050ExteriorDoors
B30ExteriorHorizontalEnclosures
B3010Roofing
B3020RoofAppurtenances
CINTERIORS
C10InteriorConstruction
C1010InteriorPartitions
C1020InteriorWindows
C1030InteriorDoors
C20InteriorFinishes
C2010WallFinishes
C2030Flooring
C2050CeilingFinishes
DSERVICES
D10Conveying
D1010VerticalConveying
D1030HorizontalConveying
D20Plumbing
D2010.40DomesticWaterPiping
D2010.60PlumbingFixtures
D2020SanitaryDrainage
D30HVAC
D3020HeatingSystems
D3030CoolingSystems
D3050HVACDistributionSystems
D3060Ventilation
D40FireProtection
D4010FireSuppression
D50Electrical
D5020ElectricalServiceandDistribution
D5030GeneralPurposeElectricPower
D5040Lighting
D70ElectronicSafetyandSecurity
D7010AccessandIntrusionControl
D7050DetectionandAlarm

TotalBuildingScore:
10
9.9to7.5
7.4to5.0
4.9to2.5
2.4to0

System
Weight
1.4
1.4
1.4
2.7
0.1

InsertScoreCardValuesinGreenCells

Adjusted
Level3
System
Score
Weights
(fromBSS)
(as%)

Weighted Normalized
Level2
Level2
Score
Score

14%
14%
14%
27%
0.0

0.1

1%

5.0

1.1
0.9

11%
9%

5.0
4.1

0.2

2%

0.9

1.5

15%

1.5

15%

5.0

1.4
0.5
0.4

14%
5%
4%

5.0
4.0

0.1

1%

1.0

0.9

9%

0.9

9%

4.5
0.3

45%
3%

0.3

3%

0.8
0.3
0.3
0.2
1.6
0.4
0.4

8%
3%
3%
2%
16%
4%
4%

5
5

0.8

8%

2.5

0.2
0.2
1.3

2%
2%
13%

5.0
5.0
5.0

5.0
5.0

0.7

5.0

0.1

5.0

5.0
5

5
5
5

0.8

0.3

0.5

0.2

5.0
5.0
1.9
1.9
1.3
5.0
1.3
1.3

0.7

7%

2.7

0.6
0.3

6%
3%

2.3
5.0

0.3

3%

5.0

Average

0.6

5.0

5.0
5

Comment

0.4

0.8

0.1
0.7

0.2

5.0

Excellent
Good
Average
Poor
Fail

2012 City of Los Angeles. All rights reserved.

EXAMPLE: For illustrative purposes Level 3 Score of 5.0 used for all fields

SiteImprovements/Grounds
Assessor:

Date:

Systems
as
UniformatLevels1,2and3
GSITEWORK
G20SiteImprovements
G2010Roadways
G2020ParkingLots
G2030PedestrianPaving
G2040SiteDevelopment
G40SiteElectricalUtilities
G4010SiteLighting

TotalBuildingScore:
10
9.9to7.5
7.4to5.0
4.9to2.5
2.4to0

System
Weight
10
8

Adjusted
Weighted
Normalized
System Level3Score
Level2
Level2Score
Weights (fromBSS)
Score
(as%)
100%
4.0
80%
5.0

40%

2.5

2
2
2
2

20%
20%
20%
20%

5
5

1.3
1.3
5.0
5.0

Average

ActionItem/Comment

1.0

5.0

Excellent
Good
Average
Poor
Fail

2012 City of Los Angeles. All rights reserved.

FACILTYDATACOLLECTIONINFORMATION
Campus:
FacilityTypeCode:
FacilityID
LegacyName:

CampusArea:
InspectionType:
Inspector'sName:
InspectionDate:

SYSTEM/COMPONENTINFORMATION
SystemID:
ComponentID:
Est.RemainingLife:

DeficiencyRefNo.

SystemTypeCode:
Comp.TypeCode:
UniformatCode:

WorkType

SubWork
Description

Priority

DeficiencyDescription

Quantity

UoM

Photo#

2012 City of Los Angeles. All rights reserved.

FACILITYOFFICEDATAPROCESSREQUIREMENTS
DeficiencyRef
No.

Work
Type

UniformatCode

Locations
(rooms)

SubWork
Description

Priority

DeficiencyDescription

Maintenance/Repair/ReplacementScenario

Quantity

UoM

Photo#

CraftCode
Material Equipment
No.Hours
TotalCost
(s)
Costs
Costs

2012 City of Los Angeles. All rights reserved.

LAWA FACILITY FIXED ASSET CAPITALIZATION FORM


Asset ID (Ai.)

Date (Avii.)

Asset Name (Aii.)

Submitted By (Aviii.)

Location (Aiii.)

Construction/Acquisition Cost (Aix.)

Asset / Facility Type (Aiv.)

WBS/Total Capital Cost (Ax.)

Construction Date (Av.)

Annual Projected Custodial (Axi.)

Projected Asset Life in Years (Avi.)

Annual Projected Utility (Axii.)

Asset System/Component

(Bi.)

UNIFORMAT/
FMS ID
(Bii.)

Substructure
Exterior Enclosure
Roof
Interior Construction
Interior Finishes
Conveying Systems (Elevator/Escalator)
Plumbing
HVAC
Fire Protection
Electrical
Communications and Security
Fixed Building Equipment (BHS, etc)

A
B20
B10/B30
C10
C30
D10
D20
D30
D40
D50
D5030
E10

Construction/Acquistion Costs
Date
(Ci.)

QTY
(Cii.)

UOM
(Ciii.)

Cost
(Civ.)

SY
SF
SF
SF
SF
EA
SF
SF
SF
SF
SF
EA
TOTAL COST:

Other Costs
(Cv.)

$0
$0
$0
$0
$0
$0
$0
$0
$0
$0
$0
$0
$0

$0
$0
$0
$0
$0
$0
$0
$0
$0
$0
$0
$0
$0

Design Life Annualized Value

Total Cost
(Cvi.)

(Di.)

$0
$0
$0
$0
$0
$0
$0
$0
$0
$0
$0
$0
$0

50
15
15
8
8
15
30
30
30
30
5
30

(Dii.)

Annual
Maintenance

Average Annual Renewal


(Projected)

(Projected)
(Diii.)

$0
$0
$0
$0
$0
$0
$0
$0
$0
$0
$0
$0
$0

$0
$0
$0
$0
$0
$0
$0
$0
$0
$0
$0
$0
$0

(Div.)

Annual Operating Cost


(Projected)

$0
$0
$0
$0
$0
$0
$0
$0
$0
$0
$0
$0
$0

(Dv.)

Total Cost of
Ownership (Projected)
(Dvi.)

$0
$0
$0
$0
$0
$0
$0
$0
$0
$0
$0
$0
$0

$0
$0
$0
$0
$0
$0
$0
$0
$0
$0
$0
$0
$0

Version 1

Facility Fixed Asset Capitalization

Total Cost of Ownership

Notes/Instructions:
1
2
3
4
5
6
7
8
9
10
11
12

Blue highlighted fields are the only areas intended for data entry or modification
Rows should be inserted for multiple systems or non-homogeneous systems
There may be multiple lines for an Asset System if the design life varies or it is desirable to track the system uniqely from a financial depreciation standpoint
UNIFORMAT ID/FMS ID is based on the LAWA FMS ID protocol
Construction Cost Information is for the Building System, not overall Asset
Other Costs is non-construction costs allocated to each system on a pro-rata basis
Design Life is the specified design life for the system.
Annualized Value is Total Construction Cost on an annualized basis
Annual Utility Cost is the projected Annual Utility Cost for the entire Asset (GSF x $/GSF)
Annual Maintenance is the projected annual maintenance for the system
Renewal is the projected renewal cost for systems with a design liife less than Projected Asset Life
Custodial is the projected Annual Custodial

2012 City of Los Angeles. All rights reserved.

Information Technology Change Assessment Form


Subject
Originating Division
Contact Name & Phone
Submittal Date
Workflow process

Software

Nonstandard
Hardware

Category:
New

Change

New

Change

New

Change

Standards
New

Change

Requested Action:

General Description:

Business Process Impacts:

Technical Assessment:

Benefits:

Costs:

Staffing Needs:

Timeframe:

Originator: Do Not Complete Section Below

Requesting Division Coordinator Review:

Division Coordinator Initials and Comments:

Division Coordinator Initials and Comments:

Division Coordinator Initials and Comments:

2012 City of Los Angeles. All rights reserved.

Information Technology Change Assessment Form


Division Coordinator Initials and Comments:

Division Manager Review:

Authorization:

Approved

Disapproved

Approved

Disapproved

FMG Director review:

Authorization:
Comments:

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

Page:
Date:

12B.1-1
02/29/12

DATA DICTIONARY

Section Contents
SECTION CONTENTS ............................................................................................................................................................1
DATA DICTIONARY DEFINITIONS ............................................................................................................................................6
1.0

Fencing (FEN) .................................................................................................................................................7

2.0

Gates (GAT) ....................................................................................................................................................8

3.0

Landscaping (LND) ..........................................................................................................................................9

3.1

Ground Cover/Turf (GCT) .............................................................................................................................. 10

3.2

Irrigation (IRR) ............................................................................................................................................... 11

4.0

Apron (APR) .................................................................................................................................................. 12

4.1

Apron Marking System (APM) ....................................................................................................................... 13

4.2

Apron Lighting System (APL)......................................................................................................................... 14

5.0

Bridges (BRD)................................................................................................................................................ 15

6.0

Parking Lots (PKL) ......................................................................................................................................... 16

7.0

Roads (RDS) ................................................................................................................................................. 17

7.1.1

Signs (SGN)................................................................................................................................................... 18

8.0

Runway (RWY) .............................................................................................................................................. 19

8.1

Runway Marking System (RNM) .................................................................................................................... 20

8.2

Runway Lighting System (RNL) ..................................................................................................................... 21

9.0

Taxiway (TWY) .............................................................................................................................................. 22

9.1

Taxiway Marking System (TWM) ................................................................................................................... 23

9.2

Taxiway Lighting System (TWL) .................................................................................................................... 24

10.0

Jet Blast Deflector (JBD)................................................................................................................................ 25

11.0

Tunnels (TNL) ................................................................................................................................................ 26

11.1

Ventilation (VNT) ........................................................................................................................................... 28

11.1.1

Exhaust Fan (EXF) ........................................................................................................................................ 29

11.2

Lighting System (LGT) ................................................................................................................................... 31

12.0

Building .......................................................................................................................................................... 32

12.1

Exterior Closure (EXT) ................................................................................................................................... 34

12.1.1

Commercial Overhead Door (CDR) ............................................................................................................... 36

12.2

Interior Finishes (INF) .................................................................................................................................... 38

12.3

Conveyance (CVY) ........................................................................................................................................ 39

12.3.1

Elevator (ELV) ............................................................................................................................................... 40

12.3.2

Escalator (ESC) ............................................................................................................................................. 42

12.3.3

Moving Walkway (MWW) ............................................................................................................................... 44

12.4

Electrical Service and Distribution (ESD) ....................................................................................................... 46

12.5

Electrical (ELC) .............................................................................................................................................. 47


2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

Page:
Date:

12B.1-2
02/29/12

DATA DICTIONARY

12.5.1

Generator (GEN) ........................................................................................................................................... 48

12.5.2

Distribution Panel (EDP) ................................................................................................................................ 49

12.5.3

Transformer (TNF) ......................................................................................................................................... 50

12.5.4

Switchboard (SWB)........................................................................................................................................ 51

12.5.5

mOTOR cONTROL CENTER (mcc) .............................................................................................................. 52

12.6

Fire Protection (FPS) ..................................................................................................................................... 53

12.6.1

Fire Alarm Control Panel (FCP) ..................................................................................................................... 54

12.7

Heat Generating System (HGS) .................................................................................................................... 55

12.8

Cooling Generating System (CGS) ................................................................................................................ 56

12.9

HVAC (HVA) .................................................................................................................................................. 57

12.9.1

Air Handling Unit (AHU) ................................................................................................................................. 58

12.9.2

Condensing Unit (CDN) ................................................................................................................................. 60

12.9.3

Exhaust Fan (EXF) ........................................................................................................................................ 61

12.10

Mechanical (MEC) ......................................................................................................................................... 63

12.10.1 Compressor (CMP) ........................................................................................................................................ 64


12.10.2 Pump (PMP) .................................................................................................................................................. 66
12.11

Plumbing System (PLM) ................................................................................................................................ 68

12.12

Rest Room (RRM) ......................................................................................................................................... 69

12.13

Roofing (ROF) ............................................................................................................................................... 71

12.14

Building Automation System (BAS) ............................................................................................................... 73

12.15

Baggage Handling System (BHS) .................................................................................................................. 74

12.16

Passenger Boarding Bridge (PBB) ................................................................................................................ 75

12.17

Communication (COM) .................................................................................................................................. 76

12.17.1 Communication Components......................................................................................................................... 77


13.0

Communication (COM) .................................................................................................................................. 78

13.1.1

Communication Components......................................................................................................................... 79

14.0

Fuel (FUL)...................................................................................................................................................... 80

14.1.1

Fuel Tanks (FT) ............................................................................................................................................. 81

15.0

Natural Gas (NTG) ......................................................................................................................................... 82

16.0

Storm Drain (SDN) ......................................................................................................................................... 83

17.0

Water (WTR).................................................................................................................................................. 84

18.0

Compressed Air (CMA) .................................................................................................................................. 85

19.0

Industrial Waste (INW) ................................................................................................................................... 86

19.1.1

tRASH cOMPACTOR (TRC) .......................................................................................................................... 87

20.0

Electrical (ELE) .............................................................................................................................................. 88

21.0

Heat/Cool Distribution (HCD) ......................................................................................................................... 89

22.0

Registered components NO ATTRIBUTES ................................................................................................ 90


2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

Page:
Date:

12B.1-3
02/29/12

DATA DICTIONARY

Appendix 3C: ASTM UNIFORMAT II Classification for Building Elements (E1557-97) ................................................ 91

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

Page:
Date:

12B.1-4
02/29/12

DATA DICTIONARY

The LAWA Facilities Management System employs a structure of facilities, systems and components
defined below and in Table 12B.1-1.

Hierarchical Level:

Facility

Facility Group:
Code
Description:

Defined in Table 12B.1-1


Defined in Table 12B.1-1
Facility identifiers represent a single constructed item versus a complex
assembly of structures.

Hierarchical Level:

System

Facility Association:
Code
Description:

Varies depending on the facility to which the system belongs.


Follows naming procedure and code indicated in this document.
System identifiers represent an associated complex assembly of components.

Hierarchical Level:

Component

System Association:
Code
Description:

Various depending upon the system to which the component belongs.


Follows naming procedure and code indicated in this document.
Component identifiers represent a single device or piece of equipment in a
system.

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-5
02/29/12

DATA DICTIONARY

Table 12B.1-1 Facility Groups, Types and Codes

Facility Group / Class

Grounds

Transportation Infrastructure

Building

Utility Infrastructure

Facility Type

Code

Fencing

FEN

Gates

GAT

Landscaping

LND

Aprons

APR

Bridges

BRD

Parking Lots

PKL

Roads

RDS

Runway

RWY

Taxiway

TWY

Blast Fence

BLF

Tunnels

TNL

Central Utility Plant

CUP

Cargo

CRG

Office

OFF

Parking Structure

PKS

Terminal

TER

Communication

COM

Fuel

FUL

Natural Gas

NTG

Storm Water

STW

Sanitary Sewer

SWR

Water

WTR

Compressed Air

CMS

Industrial Waste

INW

Electrical

ELE

Heat / Cool Distribution

HCD

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

Page:
Date:

12B.1-6
02/29/12

DATA DICTIONARY

Data Dictionary Definitions


Attribute:

A characteristic or feature of a facility, system or component.

Data Type:

A category of data. Typical data types are logical (true/false), numeric, alphanumeric
(character), and dates. When data are assigned a type, they cannot be treated like
another type. For example, alphanumeric data cannot be calculated and digits within
numeric data cannot be isolated. Date types can only contain valid dates.

Unit:

A unit (of measurement) is a definite magnitude of a physical quantity that is used as a


standard for measurement of the same physical quantity.

Domain:

A domain is the set of possible data values of an attribute, which have a standard set of
characteristics.

Range
of Values:

The range specifies the lower and upper boundaries of the values that an attribute may
legally have.

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-7
02/29/12

DATA DICTIONARY

1.0

FENCING (FEN)

Hierarchical Level:

Facility

Facility Group:

Grounds

Code:

FEN

Description:

A structure serving as an enclosure, a barrier or a boundary; usually made of posts or


stakes joined together by boards, wires or rails; includes boundary walls.

Attribute

Data Type

Unit

Domain / Range of Values

Var

N/A

System generated unique id for the entity | barcode

SAP ID

Var

N/A

ID used to reference SAP Asset

FSC ID

Var

N/A

Unique id for the entity | FEN.### for the Facility


based upon the FSC naming convention

Fence Description

Note

N/A

A narrative description of the entity

Fence Type

Combo

N/A

Chain link, architectural, other

Criticality

Number

N/A

1, 2, 3, 4, 5

Legacy Names

Var

N/A

Common name or previous name of the entity

Date Entered

Date

N/A

Condition Rating

Number

N/A

System date of when the record was entered into


the database
Condition rating of the facility

Inspection Date

Date

N/A

Date of the last inspection for the condition rating

Year Built

Date

N/A

Year that the facility was constructed

Design Life

Number

N/A

Design life

Remaining Useful Life

Number

N/A

Remaining useful life estimate

Original Construction
Cost
Replacement Cost

Number

$US

Cost of initial construction or purchase cost

Currency

$US

Current replacement value of the facility

Airfield Security

Integer

Y/N

Is the fence for Airfield security?

Length

Number

ft

Total length of fencing

Height

Number

ft

Average height of fencing

Security Wire

Combo

Y/N

Campus Location

Combo

N/A

Razor wire, Galvanized 4 point barb wire,


Permafuse 4 point barb wire, None
LAX, VNY, ONT, PMD

Address

Var

N/A

Physical address if applicable

Location ID

Var

N/A

Uniformat Code

Var

N/A

Geographic Information System (GIS) Coordinate,


Building ID, or other location reference.
G2041

Fence ID

Grey highlighted fields indicate a field that must contain information.

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-8
02/29/12

DATA DICTIONARY

2.0

GATES (GAT)

Hierarchical Level:

Facility

Facility Group:

Grounds

Code:

GAT

Description:

A structure that can be swung, drawn or lowered to block an entrance or passageway.

Attribute

Data Type

Unit

Domain / Range of Values

Gate ID

Var

N/A

System generated unique id for the entity | barcode

SAP ID

Var

N/A

ID used to reference SAP Asset

FSC ID

Var

N/A

Unique id for the entity | GAT.### for the Facility


based upon the FSC naming convention

Gate Description

Note

N/A

A narrative description of the entity

Combo

N/A

Criticality

Number

N/A

Swing gate, Vertical gate, Draw gate, Crash gate,


Rolling gate
1, 2, 3, 4, 5

Legacy Names

Var

N/A

Common name or previous name of the entity

Date Entered

Date

N/A

Condition Rating

Number

N/A

System date of when the record was entered into


the database
Condition rating of the facility

Inspection Date

Date

N/A

Date of the last inspection for the condition rating

Year Built

Date

N/A

Year that the facility was constructed

Design Life

Number

N/A

Design life

Remaining Useful Life

Number

N/A

Remaining useful life estimate

Original Construction
Cost
Replacement Cost

Number

$US

Cost of initial construction or purchase cost

Currency

$US

Current replacement value of the facility

Airfield Security

Integer

Y/N

Is the fence for Airfield security?

Length

Number

ft

Total length of the gate

Height

Number

ft

Average height of fencing

Motorized

Integer

Y/N

Is the gate motorized?

Security Wire

Combo

Y/N

Campus Location

Combo

N/A

Razor wire, Galvanized 4 point barb wire,


Permafuse 4 point barb wire, None
LAX, VNY, ONT, PMD

Address

Var

N/A

Physical address if applicable

Location ID

Var

N/A

Uniformat Code

Var

N/A

GIS Coordinate, Building ID, or other location


reference.
G2041

Gate Type

Grey highlighted fields indicate a field that must contain information.

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-9
02/29/12

DATA DICTIONARY

3.0

LANDSCAPING (LND)

Hierarchical Level:

Facility

Facility Group:

Grounds

Code:

LND

Description:

Areas that contain vegetation, rock, wood, and/or other natural or manufactured
materials placed to improve appearance, control erosion, screen views, or control
vehicular or personnel traffic as a part of an anti-terrorism plan.

Attribute

Data Type

Unit

Domain / Range of Values

Landscape ID

Var

N/A

System generated unique id for the entity | barcode

SAP ID

Var

N/A

ID used to reference SAP Asset

FSC ID

Var

N/A

Unique id for the entity | LND.### for the Facility


based upon the FSC naming convention

Landscape Description

Note

N/A

A narrative description of the entity

Landscape Type

Combo

N/A

Bed, Turf, Hardscape

Criticality

Number

N/A

1, 2, 3, 4, 5

Legacy Names

Var

N/A

Common name or previous name of the entity

Date Entered

Date

N/A

Condition Rating

Number

N/A

System date of when the record was entered into


the database
Condition rating of the facility

Inspection Date

Date

N/A

Date of the last inspection for the condition rating

Year Built

Date

N/A

Year that the facility was constructed

Design Life

Number

N/A

Design life

Remaining Useful Life

Number

N/A

Remaining useful life estimate

Original Construction Cost

Number

$US

Cost of initial construction or purchase cost

Replacement Cost

Currency

$US

Current replacement value of the facility

Area

Number

SF

Total square footage of the landscape area

Campus Location

Combo

N/A

LAX, VNY, ONT, PMD

Address

Var

N/A

Physical address if applicable

Location ID

Var

N/A

Uniformat Code

Var

N/A

GIS Coordinate, Building ID, or other location


reference.
G2050

Grey highlighted fields indicate a field that must contain information.

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-10
02/29/12

DATA DICTIONARY

3.1

GROUND COVER/TURF (GCT)

Hierarchical Level:

System

Grounds Association:

Landscaping

Code:

GCT

Description:

The description of the plantings in the landscape area.

Attribute

Data Type

Unit

Domain / Range of Values

Plant ID

Var

N/A

System generated unique id for the entity | barcode

SAP ID

Var

N/A

ID used to reference SAP Asset

FSC ID

Var

N/A

Unique id for the entity | GCT.### for the Facility


based upon the FSC naming convention

Plant Description

Note

N/A

A narrative description of the entity

Plant Type

Combo

N/A

Shrub, Tree, Flower, Bush

Criticality

Number

N/A

1, 2, 3, 4, 5

Legacy Names

Var

N/A

Common name or previous name of the entity

Date Entered

Date

N/A

Condition Rating

Number

N/A

System date of when the record was entered into the


database
Condition rating of the system

Inspection Date

Date

N/A

Date of the last inspection for the condition rating

Year Built

Date

N/A

Year that the system was constructed

Design Life

Number

N/A

Design life

Remaining Useful Life

Number

N/A

Remaining useful life estimate

Original Construction
Cost
Replacement Cost

Number

$US

Cost of initial construction or purchase cost

Currency

$US

Current replacement value of the system

Scientific name

Combo

N/A

Common Name

N/A

N/A

Quantity

Number

ea / sf

Height

Number

ft

Scientific name for the plant linked to the common


name for the plant
Common name for the plant linked to the scientific
name
The number of individual plants are or the total
coverage for ground cover in the landscape
Average height of the plant at maturity

Color

Var

N/A

Color of the foliage, flowers of the plant

Native

Integer

Y/N

Is the plant native to the area.

Campus Location

Combo

N/A

LAX, VNY, ONT, PMD

Address

Var

N/A

Physical address if applicable

Location ID

Var

N/A

Uniformat Code

Var

N/A

GIS Coordinate, Building ID, or other location


reference.
G2055

Grey highlighted fields indicate a field that must contain information.

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-11
02/29/12

DATA DICTIONARY

3.2

IRRIGATION (IRR)

Hierarchical Level:

System

Grounds Association:

Landscaping

Code:

IRR

Description:

A network of valves, chemical feeders, weather stations and/or control devices (manual
or automatic) connected by piping or channels to a water source (potable or nonpotable) that distribute water to; flood zones, sprinkler heads, and/or drip lines for the
purpose of watering vegetation.

Attribute

Data Type

Unit

Domain / Range of Values

Irrigation ID

Var

N/A

System generated unique id for the entity | barcode

SAP ID

Var

N/A

ID used to reference SAP Asset

FSC ID

Var

N/A

Unique id for the entity | IRR.### for the Facility


based upon the FSC naming convention

Irrigation Description

Note

N/A

A narrative description of the entity

Irrigation Type

Combo

N/A

Criticality

Number

N/A

Ditch, Terraced, Drip, Sprinkler, Rotary, Center


pivot
1, 2, 3, 4, 5

Legacy Names

Var

N/A

Common name or previous name of the entity

Date Entered

Date

N/A

Condition Rating

Number

N/A

System date of when the record was entered into


the database
Condition rating of the system

Inspection Date

Date

N/A

Date of the last inspection for the condition rating

Year Built

Date

N/A

Year that the system was constructed

Design Life

Number

N/A

Design life

Remaining Useful Life

Number

N/A

Remaining useful life estimate

Original Construction
Cost
Replacement Cost

Number

$US

Cost of initial construction or purchase cost

Currency

$US

Current replacement value of the system

Warranty Period

Date

N/A

The end date of the warranty period for the system

Size

Number

SF

Campus Location

Combo

N/A

The square footage of coverage for the irrigation


system.
LAX, VNY, ONT, PMD

Address

Var

N/A

Physical address if applicable

Location ID

Var

N/A

Uniformat Code

Var

N/A

GIS Coordinate, Building ID, or other location


reference.
G2057

Grey highlighted fields indicate a field that must contain information.

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-12
02/29/12

DATA DICTIONARY

4.0

APRON (APR)

Hierarchical Level:

Facility

Facility Group:

Transportation Infrastructure

Code:

APR

Description:

An area used for parking aircraft, or moving aircraft from a terminal, hangar, storage, or
maintenance area to another structure, runway, or helipad.

Attribute

Data Type

Unit

Domain / Range of Values

Apron ID

Var

N/A

System generated unique id for the entity | barcode

SAP ID

Var

N/A

ID used to reference SAP Asset

FSC ID

Var

N/A

Unique id for the entity | APR.### for the Facility


based upon the FSC naming convention

Apron Description

Note

N/A

A narrative description of the entity

Criticality

Number

N/A

1, 2, 3, 4, 5

Legacy Names

Var

N/A

Common name or previous name of the entity

Date

N/A

Condition Rating

Number

N/A

System date of when the record was entered into the


database
Condition rating of the facility

Inspection Date

Date

N/A

Date of the last inspection for the condition rating

Year Built

Date

N/A

Year that the facility was constructed

Design Life

Number

N/A

Design life

Remaining Useful Life

Number

N/A

Remaining useful life estimate

Original Construction
Cost
Replacement Cost

Number

$US

Cost of initial construction or purchase cost

Currency

$US

Current replacement value of the facility

Apron Area

Number

SF

The square footage of apron area.

Aircraft Served

Combo

N/A

Airplane types

Campus Location

Combo

N/A

LAX, VNY, ONT, PMD

Address

Var

N/A

Physical address if applicable

Location ID

Var

N/A

Uniformat Code

Var

N/A

GIS Coordinate, Building ID, or other location


reference.
G2010

Date Entered

Grey highlighted fields indicate a field that must contain information.

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-13
02/29/12

DATA DICTIONARY

4.1

APRON MARKING SYSTEM (APM)

Hierarchical Level:

System

Facility Association:

Aprons

Code:

APM

Description:

Markings on the apron pavement and other apron markers used to guide/position
aircraft.

Attribute
System ID

Data Type
Var

Unit
N/A

Domain / Range of Values


System generated unique id for the entity | barcode

SAP ID

Var

N/A

ID used to reference SAP Asset

FSC ID

Var

N/A

Unique id for the entity | APM.### for the Facility


based upon the FSC naming convention

System Description

Note

N/A

A narrative description of the entity

Criticality

Number

N/A

1, 2, 3, 4, 5

Legacy Names

Var

N/A

Common name or previous name of the entity

Date Entered

Date

N/A

Condition Rating

Number

N/A

System date of when the record was entered into


the database
Condition rating of the system

Inspection Date

Date

N/A

Date of the last inspection for the condition rating

Year Built

Date

N/A

Year that the system was constructed

Design Life

Number

N/A

Design life

Remaining Useful Life

Number

N/A

Remaining useful life estimate

Original Construction
Cost
Replacement Cost

Number

$US

Cost of initial construction or purchase cost

Currency

$US

Current replacement value of the system

Campus Location

Combo

N/A

LAX, VNY, ONT, PMD

Address

Var

N/A

Physical address if applicable

Location ID

Var

N/A

Uniformat Code

Var

N/A

GIS Coordinate, Building ID, or other location


reference.
G2016

Grey highlighted fields indicate a field that must contain information.

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-14
02/29/12

DATA DICTIONARY

4.2

APRON LIGHTING SYSTEM (APL)

Hierarchical Level:

System

Facility Association:

Aprons

Code:

APL

Description:

Apron lighting system used to guide/position aircraft.

Attribute
System ID

Data Type
Var

Unit
N/A

Domain / Range of Values


System generated unique id for the entity | barcode

SAP ID

Var

N/A

ID used to reference SAP Asset

FSC ID

Var

N/A

Unique id for the entity | APL.### for the Facility


based upon the FSC naming convention

System Description

Note

N/A

A narrative description of the entity

Criticality

Number

N/A

1, 2, 3, 4, 5

Legacy Names

Var

N/A

Common name or previous name of the entity

Date Entered

Date

N/A

Condition Rating

Number

N/A

System date of when the record was entered into


the database
Condition rating of the system

Inspection Date

Date

N/A

Date of the last inspection for the condition rating

Year Built

Date

N/A

Year that the system was constructed

Design Life

Number

N/A

Design life

Remaining Useful Life

Number

N/A

Remaining useful life estimate

Original Construction
Cost
Replacement Cost

Number

$US

Cost of initial construction or purchase cost

Currency

$US

Current replacement value of the system

Warranty Period

Date

N/A

Year the warranty expires on the system

Number of fixtures

Number

Each

Number of light fixtures

Fixture Type

Combo

N/A

Elevated, in-pavement, Edge

Voltage

Number

Volts

Voltage of the system

Campus Location

Combo

N/A

LAX, VNY, ONT, PMD

Address

Var

N/A

Physical address if applicable

Location ID

Var

N/A

Uniformat Code

Var

N/A

GIS Coordinate, Building ID, or other location


reference.
G2016

Grey highlighted fields indicate a field that must contain information.

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-15
02/29/12

DATA DICTIONARY

5.0

BRIDGES (BRD)

Hierarchical Level:

Facility

Facility Group:

Transportation Infrastructure

Code:

BRD

Description:

A bridge is a structure erected over a waterway, road, or other obstruction, having a


track or passageway for vehicular or pedestrian traffic or other moving loads.

Attribute

Data Type

Unit

Domain / Rang of Values

Bridge ID

Var

N/A

System generated unique id for the entity | barcode

SAP ID

Var

N/A

ID used to reference SAP Asset

FSC ID

Var

N/A

Unique id for the entity | CALTRANS ID or BRD.### for non


DOT bridges.

Bridge Description

Note

N/A

A narrative description of the entity

Bridge Type

Combo

N/A

Criticality

Number

N/A

Beam, Cantilever, Arch, Suspension, Cable-stayed, Movable,


Double-decked
1, 2, 3, 4, 5

Legacy Names

Var

N/A

Common name or previous name of the entity

Date Entered

Date

N/A

Condition Rating

Number

N/A

System date of when the record was entered into the


database
Condition rating of the facility; NBIS rating

Inspection Date

Date

N/A

Date of the last inspection for the condition rating

Year Built

Date

N/A

Year that the facility was constructed

Design Life

Number

N/A

Design life

Remaining Useful Life

Number

N/A

Remaining useful life estimate

Original Construction
Cost
Replacement Cost

Number

$US

Cost of initial construction or purchase cost

Currency

$US

Current replacement value of the facility

Deck Material

Combo

N/A

Concrete, Asphalt, other

Deck Width

Number

ft

Width of the bridge deck

Deck Length

Number

ft

Length of the bridge deck

Installation Date

Date

N/A

Date the bridge was put into service

Load Rating

Number

lbs

Load rating of the bridge

Vertical Clearance

Number

ft

Minimum clear distance under the bridge

Sufficiency Rating

Number

N/A

NBIS rating

Campus Location

Combo

N/A

LAX, VNY, ONT, PMD

Address

Var

N/A

Physical address if applicable

Location ID

Var

N/A

GIS Coordinate, Building ID, or other location reference.

Uniformat Code

Var

N/A

G2017

Grey highlighted fields indicate a field that must contain information.

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-16
02/29/12

DATA DICTIONARY

6.0

PARKING LOTS (PKL)

Hierarchical Level:

Facility

Facility Group:

Transportation Infrastructure

Code:

PKL

Description:

An area used for the temporary occupation of vehicles, equipment, or stored materials.

Attribute

Data Type

Unit

Domain / Range of Values

Lot ID

Var

N/A

System generated unique id for the entity | barcode

SAP ID

Var

N/A

ID used to reference SAP Asset

FSC ID

Var

N/A

Unique id for the entity | PKL.### for the Facility


based upon the FSC naming convention

Lot Description

Note

N/A

A narrative description of the entity

Lot Use

Combo

N/A

Waiting, Parking, Service Vehicles, Temporary

Criticality

Number

N/A

1, 2, 3, 4, 5

Legacy Names

Var

N/A

Common name or previous name of the entity

Date Entered

Date

N/A

Condition Rating

Number

N/A

System date of when the record was entered into the


database
Condition rating of the facility

Inspection Date

Date

N/A

Date of the last inspection for the condition rating

Year Built

Date

N/A

Year that the facility was constructed

Design Life

Number

N/A

Design life

Remaining Useful Life

Number

N/A

Remaining useful life estimate

Original Construction
Cost
Replacement Cost

Number

$US

Cost of initial construction or purchase cost

Currency

$US

Current replacement value of the facility

Surface Type

Combo

N/A

Asphalt, Concrete, Other

Fenced

Integer

Y/N

Is the lot fenced?

Area

Number

SF

Are of the parking lot

Space Quantity

Number

Each

Number of designated (marked) parking spaces

Campus Location

Combo

N/A

LAX, VNY, ONT, PMD

Address

Var

N/A

Physical address if applicable

Location ID

Var

N/A

Uniformat Code

Var

N/A

GIS Coordinate, Building ID, or other location


reference.
G2020

Grey highlighted fields indicate a field that must contain information.

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-17
02/29/12

DATA DICTIONARY

7.0

ROADS (RDS)

Hierarchical Level:

Facility

Facility Group:

Transportation Infrastructure

Code:

RDS

Description:

A maintained right-of-way used for the passage of traffic. Roadways may be for airport,
airline, public, security, or maintenance use and are generally engineered/designed for
the passage of vehicular traffic. The roadways can be inside and outside the AOA.

Attribute

Data Type

Unit

Domain / Range of Values

Road ID

Var

N/A

System generated unique id for the entity | barcode

SAP ID

Var

N/A

ID used to reference SAP Asset

FSC ID

Var

N/A

Unique id for the entity | RDS.### for the Facility based


upon the FSC naming convention

Road Description

Note

N/A

A narrative description of the entity

Road Type

Combo

N/A

Alley, Arterial, Service, Dead-end

Criticality

Number

N/A

1, 2, 3, 4, 5

Legacy Names

Var

N/A

Common name or previous name of the entity

Date Entered

Date

N/A

Condition Rating

Number

N/A

System date of when the record was entered into the


database
Condition rating of the facility

Inspection Date

Date

N/A

Date of the last inspection for the condition rating

Year Built

Date

N/A

Year that the facility was constructed

Design Life

Number

N/A

Design life

Remaining Useful Life

Number

N/A

Remaining useful life estimate

Original Construction
Cost
Replacement Cost

Number

$US

Cost of initial construction or purchase cost

Currency

$US

Current replacement value of the facility

Surface Type

Combo

N/A

Asphalt, Concrete, other

Thickness

Number

in

Thickness of the wearing course

Width

Number

ft

Average width of the road

Lanes

Number

ea

Number of lanes

Length

Number

ft

Length of the road

Condition Rating

Number

N/A

The PCI rating for the road

Condition Rating Date

Date

N/A

Date of the last condition rating

Campus Location

Combo

N/A

LAX, VNY, ONT, PMD

Address

Var

N/A

Physical address if applicable

Location ID

Var

N/A

GIS Coordinate, Building ID, or other location reference.

Uniformat Code

Var

N/A

G2010

Grey highlighted fields indicate a field that must contain information.

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-18
02/29/12

DATA DICTIONARY

7.1.1 SIGNS (SGN)

Hierarchical Level:

Component

Facility Group:

Transportation Infrastructure

Code:

SGN

Description:

Traffic signs installed to provide information to users. Signs are standardized using
MUTCD codes to provide a standard to facilitate travel and to enhance traffic safety.

Attribute

Data Type

Unit

Domain / Range of Values

Sign ID

Var

N/A

System generated unique id for the entity | barcode

SAP ID

Var

N/A

ID used to reference SAP Asset

FSC ID

Var

N/A

Unique id for the entity | SGN.### for the Facility


based upon the FSC naming convention

Sign Description

Note

N/A

A narrative description of the entity

Sign Type

Combo

N/A

California MUTCD codes

Criticality

Number

N/A

1, 2, 3, 4, 5

Legacy Names

Var

N/A

Common name or previous name of the entity

Date Entered

Date

N/A

Condition Rating

Number

N/A

System date of when the record was entered into


the database
The retro-reflectivity rating for the sign

Inspection Date

Date

N/A

Date of the last inspection for the condition rating

Installation date

Date

N/A

Year that the sign was installed

Design Life

Number

N/A

Design life

Remaining Useful Life

Number

N/A

Remaining useful life estimate

Original Construction
Cost
Replacement Cost

Number

$US

Cost of initial construction or purchase cost

Currency

$US

Current replacement value of the sign

Campus Location

Combo

N/A

LAX, VNY, ONT, PMD

Address

Var

N/A

Physical address if applicable

Location ID

Var

N/A

Uniformat Code

Var

N/A

GIS Coordinate, Building ID, or other location


reference.
G2016

Grey highlighted fields indicate a field that must contain information.

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-19
02/29/12

DATA DICTIONARY

8.0

RUNWAY (RWY)

Hierarchical Level:

Facility

Facility Group:

Transportation Infrastructure

Code:

RWY

Description:

Engineered surface constructed and maintained in accordance with FAA regulations for
the movement, take-off, and landing of fixed-wing aircraft.

Attribute

Data Type

Unit

Domain / Range of Values

Runway ID

Var

N/A

System generated unique id for the entity | barcode

SAP ID

Var

N/A

ID used to reference SAP Asset

FSC ID

Var

N/A

Unique id for the entity | RWY.### where ### is


runway designator (i.e. RWY.27L) for the Facility

Runway Description

Note

N/A

A narrative description of the entity

Runway Type

Combo

N/A

Commercial, Helicopter pad, Military, Private

Criticality

Number

N/A

1, 2, 3, 4, 5

Legacy Names

Var

N/A

Common name or previous name of the entity

Date Entered

Date

N/A

Condition Rating

Number

N/A

System date of when the record was entered into


the database
Condition rating of the facility

Inspection Date

Date

N/A

Date of the last inspection for the condition rating

Year Built

Date

N/A

Year that the facility was constructed

Design Life

Number

N/A

Design life

Remaining Useful Life

Number

N/A

Remaining useful life estimate

Original Construction
Cost
Replacement Cost

Number

$US

Cost of initial construction or purchase cost

Currency

$US

Current replacement value of the facility

Runway Width

Number

ft

Width of the runway edge to edge

Runway Length

Number

ft

Length of the runway

Runway Direction

Var

N/A

Cardinal Directions

Campus Location

Combo

N/A

LAX, VNY, ONT, PMD

Address

Var

N/A

Physical address if applicable

Location ID

Var

N/A

Uniformat Code

Var

N/A

GIS Coordinate, Building ID, or other location


reference.
G2010

Grey highlighted fields indicate a field that must contain information.

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-20
02/29/12

DATA DICTIONARY

8.1

RUNWAY MARKING SYSTEM (RNM)

Hierarchical Level:

System

Facility Association:

Runways

Code:

RNM

Description:

Markings on the runway pavement and other runway markers used to guide/position
aircraft.

Attribute
System ID

Data Type
Var

Unit
N/A

Domain / Range of Values


System generated unique id for the entity | barcode

SAP ID

Var

N/A

ID used to reference SAP Asset

FSC ID

Var

N/A

Unique id for the entity | RNM.### where ### is the


runway designator for the Facility

System Description

Note

N/A

A narrative description of the entity

System Type

Combo

N/A

Paint, Tape, Raised Pavement Marker (RPM)

Criticality

Number

N/A

1, 2, 3, 4, 5

Legacy Names

Var

N/A

Common name or previous name of the entity

Date Entered

Date

N/A

Condition Rating

Number

N/A

System date of when the record was entered into


the database
Condition rating of the system

Inspection Date

Date

N/A

Date of the last inspection for the condition rating

Year Built

Date

N/A

Year that the system was constructed

Design Life

Number

N/A

Design life

Remaining Useful Life

Number

N/A

Remaining useful life estimate

Original Construction
Cost
Replacement Cost

Number

$US

Cost of initial construction or purchase cost

Currency

$US

Current replacement value of the system

Campus Location

Combo

N/A

LAX, VNY, ONT, PMD

Address

Var

N/A

Physical address if applicable

Location ID

Var

N/A

Uniformat Code

Var

N/A

GIS Coordinate, Building ID, or other location


reference.
G2016

Grey highlighted fields indicate a field that must contain information.

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-21
02/29/12

DATA DICTIONARY

8.2

RUNWAY LIGHTING SYSTEM (RNL)

Hierarchical Level:

System

Facility Association:

Runways

Code:

RNL

Description:

Runway lighting system used to guide/position aircraft.

Attribute
System ID

Data Type
Var

Unit
N/A

Domain / Range of Values


System generated unique id for the entity |
barcode

SAP ID

Var

N/A

ID used to reference SAP Asset

FSC ID

Var

N/A

Unique id for the entity | RNL.### where ### is


the runway designator for the Facility.

System Description

Note

N/A

A narrative description of the entity

Criticality

Number

N/A

1, 2, 3, 4, 5

Legacy Names

Var

N/A

Common name or previous name of the entity

Date Entered

Date

N/A

Condition Rating

Number

N/A

System date of when the record was entered into


the database
Condition rating of the system

Inspection Date

Date

N/A

Date of the last inspection for the condition rating

Year Built

Date

N/A

Year that the system was constructed

Design Life

Number

N/A

Design life

Remaining Useful Life

Number

N/A

Remaining useful life estimate

Original Construction Cost

Number

$US

Cost of initial construction or purchase cost

Replacement Cost

Currency

$US

Current replacement value of the system

Warranty Period

Date

N/A

Year the warranty expires on the system

Number of fixtures

Number

Each

Number of light fixtures

Fixture Type

Combo

N/A

Elevated, in-pavement, Edge

Voltage

Number

Volts

Voltage of the system

Campus Location

Combo

N/A

LAX, VNY, ONT, PMD

Address

Var

N/A

Physical address if applicable

Location ID

Var

N/A

Uniformat Code

Var

N/A

GIS Coordinate, Building ID, or other location


reference.
G2016

Grey highlighted fields indicate a field that must contain information.

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-22
02/29/12

DATA DICTIONARY

9.0

TAXIWAY (TWY)

Hierarchical Level:

Facility

Facility Group:

Transportation Infrastructure

Code:

TWY

Description:

Engineered surface constructed and maintained in accordance with FAA regulations for
the movement of fixed-wing aircraft between runways, hangars, terminals, aprons, and
related AOA elements.

Attribute

Data Type

Unit

Domain / Range of Values

Taxiway ID

Var

N/A

System generated unique id for the entity | barcode

SAP ID

Var

N/A

ID used to reference SAP Asset

FSC ID

Var

N/A

Unique id for the entity | TWY.### where ### is the


runway designator for the Facility

Taxiway Description

Note

N/A

A narrative description of the entity

Taxiway Type

Combo

N/A

Way, Lane

Criticality

Number

N/A

1, 2, 3, 4, 5

Legacy Names

Var

N/A

Common name or previous name of the entity

Date Entered

Date

N/A

Condition Rating

Number

N/A

System date of when the record was entered into


the database
Condition rating of the facility

Inspection Date

Date

N/A

Date of the last inspection for the condition rating

Year Built

Date

N/A

Year that the facility was constructed

Design Life

Number

N/A

Design life

Remaining Useful Life

Number

N/A

Remaining useful life estimate

Original Construction
Cost
Replacement Cost

Number

$US

Cost of initial construction or purchase cost

Currency

$US

Current replacement value of the facility

Taxiway Width

Number

ft

Width of the Taxiway edge to edge

Taxiway Length

Number

ft

Length of the taxiway

Campus Location

Combo

N/A

LAX, VNY, ONT, PMD

Address

Var

N/A

Physical address if applicable

Location ID

Var

N/A

Uniformat Code

Var

N/A

GIS Coordinate, Building ID, or other location


reference.
G2010

Grey highlighted fields indicate a field that must contain information.

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-23
02/29/12

DATA DICTIONARY

9.1

TAXIWAY MARKING SYSTEM (TWM)

Hierarchical Level:

System

Facility Group:

Taxiway

Code:

TWM

Description:

Markings on the taxiway pavement and other taxiway markers used to guide/position
aircraft.

Attribute
System ID

Data Type
Var

Unit
N/A

Domain / Range of Values


System generated unique id for the entity | barcode

SAP ID

Var

N/A

ID used to reference SAP Asset

FSC ID

Var

N/A

Unique id for the entity | TWM.### where ### is the


runway designator for the Facility

System Description

Note

N/A

A narrative description of the entity

System Type

Combo

N/A

Paint, Tape, Raised Pavement Marker (RPM)

Criticality

Number

N/A

1, 2, 3, 4, 5

Legacy Names

Var

N/A

Common name or previous name of the entity

Date Entered

Date

N/A

Condition Rating

Number

N/A

System date of when the record was entered into


the database
Condition rating of the system

Inspection Date

Date

N/A

Date of the last inspection for the condition rating

Year Built

Date

N/A

Year that the system was constructed

Design Life

Number

N/A

Design life

Remaining Useful Life

Number

N/A

Remaining useful life estimate

Original Construction
Cost
Replacement Cost

Number

$US

Cost of initial construction or purchase cost

Currency

$US

Current replacement value of the system

Campus Location

Combo

N/A

LAX, VNY, ONT, PMD

Address

Var

N/A

Physical address if applicable

Location ID

Var

N/A

Uniformat Code

Var

N/A

GIS Coordinate, Building ID, or other location


reference.
G2016

Grey highlighted fields indicate a field that must contain information.

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-24
02/29/12

DATA DICTIONARY

9.2

TAXIWAY LIGHTING SYSTEM (TWL)

Hierarchical Level:

System

Facility Association:

Taxiways

Code:

TWL

Description:

Taxiway lighting system used to guide/position aircraft.

Attribute
System ID

Data Type
Var

Unit
N/A

Domain / Rang of Values


System generated unique id for the entity | barcode

SAP ID

Var

N/A

ID used to reference SAP Asset

FSC ID

Var

N/A

Unique id for the entity | TWL.### where ### is the


runway designator for the Facility

System Description

Note

N/A

A narrative description of the entity

Criticality

Number

N/A

1, 2, 3, 4, 5

Legacy Names

Var

N/A

Common name or previous name of the entity

Date Entered

Date

N/A

Condition Rating

Number

N/A

System date of when the record was entered into


the database
Condition rating of the system

Inspection Date

Date

N/A

Date of the last inspection for the condition rating

Year Built

Date

N/A

Year that the system was constructed

Design Life

Number

N/A

Design life

Remaining Useful Life

Number

N/A

Remaining useful life estimate

Original Construction Cost

Number

$US

Cost of initial construction or purchase cost

Replacement Cost

Currency

$US

Current replacement value of the system

Warranty Period

Date

N/A

Year the warranty expires on the system

Number of fixtures

Number

Each

Number of light fixtures

Fixture Type

Combo

N/A

Elevated, in-pavement, Edge

Voltage

Number

Volts

Voltage of the system

Campus Location

Combo

N/A

LAX, VNY, ONT, PMD

Address

Var

N/A

Physical address if applicable

Location ID

Var

N/A

Uniformat Code

Var

N/A

GIS Coordinate, Building ID, or other location


reference.
G2016

Grey highlighted fields indicate a field that must contain information.

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-25
02/29/12

DATA DICTIONARY

10.0 JET BLAST DEFLECTOR (JBD)

Hierarchical Level:

Facility

Facility Group:

Transportation Infrastructure

Code:

JBD

Description:

A jet blast deflector (JBD) or blast fence is a safety device that redirects the high
energy exhaust from a jet engine to prevent damage and injury.

Attribute

Data Type

Unit

Domain / Range of Values

Blast Fence ID

Var

N/A

System generated unique id for the entity | barcode

SAP ID

Var

N/A

ID used to reference SAP Asset

FSC ID

Var

N/A

Description

Text

N/A

Unique id for the entity | JBD.### for the Facility


based upon the FSC naming convention
A narrative description of the entity

Type

Combo

N/A

Concrete, Metal, Other

Criticality

Number

N/A

1, 2, 3, 4, 5

Legacy Names

Var

N/A

Common name or previous name of the entity

Date Entered

Date

N/A

Condition Rating

Number

N/A

System date of when the record was entered into the


database
Condition rating of the blast fence

Inspection Date

Date

N/A

Date of the last inspection for the condition rating

Year Built

Date

N/A

Year that the blast fence was constructed

Design Life

Number

N/A

Design life

Remaining Useful Life

Number

N/A

Remaining useful life estimate

Original Construction
Cost
Replacement Cost

Number

$US

Cost of initial construction or purchase cost

Currency

$US

Current replacement value of the facility

Length

Number

ft

Length of the blast fence

Height

Number

ft

Height of the blast fence

Sound Attenuators

Integer

N/A

Yes, No

Campus Location

Combo

N/A

LAX, VNY, ONT, PMD

Address

Var

N/A

Physical address if applicable

Location ID

Var

N/A

Uniformat Code

Var

N/A

GIS Coordinate, Building ID, or other location


reference.
G9090

Grey highlighted fields indicate a field that must contain information.

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-26
02/29/12

DATA DICTIONARY

11.0 TUNNELS (TNL)

Hierarchical Level:

Facility

Facility Group:

Transportation Infrastructure

Code:

TNL

Description:

A tunnel providing access/passage to pedestrian or vehicular traffic.

Attribute

Data Type

Unit

Domain / Range of Values

Tunnel ID

Var

N/A

System generated unique id for the entity | barcode

SAP ID

Var

N/A

ID used to reference SAP Asset

FSC ID

Var

N/A

Tunnel Description

Text

N/A

Unique identity for the entity | CALTRANS ID or


TNL.### for non DOT tunnels
A narrative description of the entity

Tunnel Type

Combo

N/A

Cut-and-cover, bored, Soft ground, jacked-box

Criticality

Number

N/A

1, 2, 3, 4, 5

Legacy Names

Var

N/A

Common name or previous name of the entity

Date Entered

Date

N/A

Condition Rating

Number

N/A

System date of when the record was entered into the


database
Condition rating of the facility

Inspection Date

Date

N/A

Date of the last inspection for the condition rating

Year Built

Date

N/A

Year that the facility was constructed

Design Life

Number

N/A

Design life

Remaining Useful Life

Number

N/A

Remaining useful life estimate

Original Construction
Cost
Replacement Cost

Number

$US

Cost of initial construction or purchase cost

Currency

$US

Current replacement value of the facility

Tunnel X-Section

Combo

N/A

Circular, Rectangular, Horseshoe

Liner Type

Combo

N/A

Invert Type

Combo

N/A

Unlined rock, Rock reinforcement, Shotcrete, Ribbed,


Segmental, Placed concrete, Slurry wall
On grade, above grade

Finish Type

Combo

N/A

Painted, Natural, Shotcrete

Tunnel Width

Number

ft

Width of tunnel and widest part

Tunnel Length

Number

ft

Length of tunnel

Installation Date

date

N/A

Year that the tunnel was constructed

Vertical Clearance

Number

ft

Minimum (posted) vertical clearance for traffic

Condition Rating

Number

N/A

Ventilation Types

Combo

N/A

Rating from FHWA Highway and Rail Transit Tunnel


Inspection Manual
Natural, Longitudinal, semi transverse, full

Grey highlighted fields indicate a field that must contain information.

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-27
02/29/12

DATA DICTIONARY

Ventilation equipment

Integer

N/A

transverse, etc
Yes, No

Sound Attenuators

Integer

N/A

Yes, No

Lighting System

Integer

N/A

Yes, No

Campus Location

Combo

N/A

LAX, VNY, ONT, PMD

Address

Var

N/A

Physical address if applicable

Location ID

Var

N/A

Uniformat Code

Var

N/A

GIS Coordinate, Building ID, or other location


reference.
G9010

Grey highlighted fields indicate a field that must contain information.

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-28
02/29/12

DATA DICTIONARY

11.1 VENTILATION (VNT)

Hierarchical Level:

System

Facility Association:

Tunnels

Code:

VNT

Description:

Tunnel ventilation equipment.

Attribute
System ID

Data Type
Var

Unit
N/A

Domain / Range of Values


System generated unique id for the entity | barcode

SAP ID

Var

N/A

ID used to reference SAP Asset

FSC ID

Var

N/A

Unique id for the entity | VNT.### for the Facility


based upon the FSC naming convention

System Description

Text

N/A

A narrative description of the entity

Criticality

Number

N/A

1, 2, 3, 4, 5

Legacy Names

Var

N/A

Common name or previous name of the entity

Date Entered

Date

N/A

Condition Rating

Number

N/A

System date of when the record was entered into


the database
Condition rating of the system

Inspection Date

Date

N/A

Date of the last inspection for the condition rating

Year Built

Date

N/A

Year that the system was constructed

Design Life

Number

N/A

Design life

Remaining Useful Life

Number

N/A

Remaining useful life estimate

Original Construction
Cost
Replacement Cost

Number

$US

Cost of initial construction or purchase cost

Currency

$US

Current replacement value of the system

Warranty Period

Date

N/A

The end date of the warranty period for the system

Air Handling Units, qty

Number

Each

Number of air handling units servicing the tunnel

Exhaust Removal
Systems, qty
Supply Fans, qty

Number

Each

Number

Each

Number of exhaust removal units servicing the


tunnel
Number of supply fans servicing the tunnel

Campus Location

Combo

N/A

LAX, VNY, ONT, PMD

Address

Var

N/A

Physical address if applicable

Location ID

Var

N/A

Uniformat Code

Var

N/A

GIS Coordinate, Building ID, or other location


reference.
D3042

Grey highlighted fields indicate a field that must contain information.

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-29
02/29/12

DATA DICTIONARY

11.1.1

EXHAUST FAN (EXF)

Hierarchical Level:

Component

System Association:

Ventilation

Code:

EXF

Description:

A fan for ventilating an enclosed space by moving air from the interior to the exterior of
a structure.

Attribute
Component ID

Data Type
Var

Unit
N/A

Domain / Range of Values


System generated unique id for the entity | barcode

SAP ID

Var

N/A

ID used to reference SAP Asset

FSC ID

Var

N/A

Unique id for the entity | EXF.### for the Facility


based upon the FSC naming convention

Component Description

Text

N/A

A narrative description of the entity

Component Type

Combo

N/A

axial, centrifugal, propeller, utility

System ID

Var

N/A

The system ID that the component is associated to

Criticality

Number

N/A

1, 2, 3, 4, 5

Legacy Names

Var

N/A

Common name or previous name of the entity

Date Entered

Date

N/A

Condition Rating

Number

N/A

System date of when the record was entered into the


database
Condition rating of the component

Inspection Date

Date

N/A

Date of the last inspection for the condition rating

Year Built

Date

N/A

Year that the component was constructed

Design Life

Number

N/A

Design life

Remaining Useful Life

Number

N/A

Remaining useful life estimate

Original Construction
Cost
Replacement Cost

Number

$US

Cost of initial construction or purchase cost

Currency

$US

Current replacement value of the component

CFM

Number

cfm

Air flow volume (design)

Use

Combo

N/A

Exhaust, Supply

Mount Type

Combo

N/A

Motor Manufacturer

Text

N/A

anti-vibration, base mount, close coupled, flange


mounted, horizontal mount, in-line mount, roof
mount, suspended, vertical mount, wall mount, floor
mounted, wall mounted
To be developed on-the-fly

Motor Serial Number

Var

N/A

Unique identifier for the motor

Motor Frame Size

Combo

N/A

48, 56, 143, 143T, 145, 145T, 182, 182T, 184, 184T,
203, 204, 213, 213T, 215, 215T, 224, 225, 254,
254U, 254T, 256U, 256T, 284, 284U, 284T, 284TS,
286U, 286T, 286TS, 324, 324U, 324S, 324T, 324TS,

Grey highlighted fields indicate a field that must contain information.

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-30
02/29/12

DATA DICTIONARY

Motor Voltage

Number

volts

326, 326U, 326S, 326T, 326TS, 364, 364S, 364U,


364US, 364T, 364TS, 365, 365S, 365U, 365US,
365T, 365TS, 404, 404S, 404U, 404US, 404T,
404TS, 405, 405S, 405U, 405US, 405T, 405TS, 444,
444S, 444U, 444US, 444T, 444TS, 445, 445S, 445U,
445US, 445T, 445TS, 447TS, 449TS, 504U, 505,
505S
Operating voltage for the motor

Motor Phases

Combo

N/A

1 Phase, 3 Phase

Motor Amps

Number

amps

Current draw for the motor

Motor Horse Power

Number

hp

Motor HP rating

NEMA Designation

Combo

N/A

Drip proof, Splash proof, Totally enclosed fan cooled,


Water proof, Explosion proof

Uniformat Code

Var

N/A

D3042

Grey highlighted fields indicate a field that must contain information.

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-31
02/29/12

DATA DICTIONARY

11.2 LIGHTING SYSTEM (LGT)

Hierarchical Level:

System

Facility Association:

Tunnels

Code:

LGT

Description:

Lighting system.

Attribute
System ID

Data Type
Var

Unit
N/A

Domain / Range of Values


System generated unique id for the entity | barcode

SAP ID

Var

N/A

ID used to reference SAP Asset

FSC ID

Var

N/A

Unique id for the entity | LGT.### for the Facility


based upon the FSC naming convention

System Description

Text

N/A

A narrative description of the entity

Criticality

Number

N/A

1, 2, 3, 4, 5

Legacy Names

Var

N/A

Common name or previous name of the entity

Date Entered

Date

N/A

Condition Rating

Number

N/A

System date of when the record was entered into the


database
Condition rating of the system

Inspection Date

Date

N/A

Date of the last inspection for the condition rating

Year Built

Date

N/A

Year that the system was constructed

Design Life

Number

N/A

Design life

Remaining Useful Life

Number

N/A

Remaining useful life estimate

Original Construction
Cost
Replacement Cost

Number

$US

Cost of initial construction or purchase cost

Currency

$US

Current replacement value of the system

Warranty Period

Date

N/A

The end date of the warranty period for the system

Number of fixtures

Number

Each

Number of fixtures servicing the tunnel

Fixture Type

Combo

N/A

LED, Induction

Voltage

Number

Volts

Voltage of the light fixtures

Campus Location

Combo

N/A

LAX, VNY, ONT, PMD

Address

Var

N/A

Physical address if applicable

Location ID

Var

N/A

Uniformat Code

Var

N/A

GIS Coordinate, Building ID, or other location


reference.
D5020

Grey highlighted fields indicate a field that must contain information.

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-32
02/29/12

DATA DICTIONARY

12.0 BUILDING

Hierarchical Level:

Facility

Facility Group:

Building

Code:

Terminal (TER), Office (OFF), Cargo (CRG), Aircraft Rescue Fire Fighting (ARF),
Central Utility Plant (CUP), Maintenance Buildings (MNT)

Description:

A relatively permanent enclosed construction over a plot of land, having a roof and
usually windows and often more than one level, used for any of a wide variety of
activities, as living, working, or manufacturing. Each facility may also have additional
unique characteristics beyond the basic information.

Attribute

Data Type

Unit

Domain / Range of Values

Building ID

Text

N/A

Unique name for the entity | see facility spreadsheet

SAP ID

Var

N/A

ID used to reference SAP Asset

FSC ID

Var

N/A

Building Type

Combo

N/A

Building Description

Var

Unique id for the Facility based upon the FSC


naming convention
Terminal, Office, Cargo, Aircraft Rescue
Firefighting, Parking Structure, Maintenance
A narrative description of the building

Criticality

Number

N/A

1, 2, 3, 4, 5

Legacy Names

Var

N/A

Common name or previous name of the entity

Date Entered

Date

N/A

Condition Rating

Number

N/A

System date of when the record was entered into


the database
Condition rating of the facility

Inspection Date

Date

N/A

Date of the last inspection for the condition rating

Year Built

Date

N/A

Year that the facility was constructed

Design Life

Number

N/A

Design life

Remaining Useful Life

Number

N/A

Remaining useful life estimate

Original Construction
Cost
Replacement Cost

Number

$US

Cost of initial construction or purchase cost

Currency

$US

Current replacement value of the facility

Year of Last Renovation

Date

N/A

Initial Occupancy Date

Date

N/A

Year of the last renovation that modified the


deprecation rate
Date that the building was first occupied

Ownership

Combo

N/A

LAWA, Tenant/Other

Gross Area

Number

SF

Gross square footage

Source of Area

Combo

N/A

As-built drawing, survey

Rentable Area

Number

SF

Net rentable area

Maintainable Area

Number

SF

Net area maintained

Grey highlighted fields indicate a field that must contain information.

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-33
02/29/12

DATA DICTIONARY

Attribute

Data Type

Unit

Domain / Range of Values

Circulation Area

Number

SF

Net circulation space

Budget Number

Var

N/A

Accounting number for financial transactions

Type of Construction

Combo

N/A

Temporary, Permanent

Campus Location

Combo

N/A

LAX, VNY, ONT, PMD

Address

Var

N/A

Physical address if applicable

Location ID

Var

N/A

GIS Coordinate, Building ID, or other location


reference.

All Buildings share the same basic attributes. The following buildings have additional specific attributes.

Parking Structure (PKS)

Hierarchical Level:

Facility

Facility Group:

Building

Code:

PKS

Description:

A structure or building for parking vehicles.

Attribute

Data Type

Unit

Domain / Range of Values

Number of levels

Number

Each

Number of parking levels

Number of parking stalls

Number

Each

Number of parking stalls

Grey highlighted fields indicate a field that must contain information.

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-34
02/29/12

DATA DICTIONARY

12.1 EXTERIOR CLOSURE (EXT)

Hierarchical Level:

System

Facility Association:

Terminal

Code:

EXT

Description:

Exterior enclosure of a building including walls, doors and windows, excluding roofs.

Attribute

Data Type

Unit

Domain / Range of Values

System ID

Var

N/A

System generated unique id for the entity | barcode

SAP ID

Var

N/A

ID used to reference SAP Asset

FSC ID

Var

N/A

Unique id for the entity | EXT.### for the Facility


based upon the FSC naming convention

System Description

Text

N/A

A narrative description of the entity

Criticality

Number

N/A

1, 2, 3, 4, 5

Legacy Names

Var

N/A

Common name or previous name of the entity

Date Entered

Date

N/A

Condition Rating

Number

N/A

System date of when the record was entered into


the database
Condition rating of the system

Inspection Date

Date

N/A

Date of the last inspection for the condition rating

Year Built

Date

N/A

Year that the system was constructed

Design Life

Number

N/A

Design life

Remaining Useful Life

Number

N/A

Remaining useful life estimate

Original Construction
Cost
Replacement Cost

Number

$US

Cost of initial construction or purchase cost

Currency

$US

Current replacement value of the system

Commercial Overhead
Doors, qty
Exterior Doors, qty

Number

ea

Total number of overhead doors

Number

ea

Total number of exterior doors

Fixed Aluminum Single


Pane Windows, qty
Fixed Aluminum Double
Pane/Thermal
Windows, qty
Aluminum Store Front
Swing Double Doors,
qty
Glass Store Front
Sliding Double Doors,
qty
Steel Solid Core Swing
Double Doors, qty

Number

ea

Number of windows

Number

ea

Number of windows

Number

ea

Number of doors

Number

ea

Number of doors

Number

ea

Number of doors

Grey highlighted fields indicate a field that must contain information.

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-35
02/29/12

DATA DICTIONARY

Attribute

Data Type

Unit

Domain / Range of Values

Steel Solid Core Swing


Single Doors, qty
Campus Location

Number

ea

Number of doors

Combo

N/A

LAX, VNY, ONT, PMD

Address

Var

N/A

Physical address if applicable

Location ID

Var

N/A

Uniformat Code

Var

N/A

GIS Coordinate, Building ID, or other location


reference.
B20

Grey highlighted fields indicate a field that must contain information.

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-36
02/29/12

DATA DICTIONARY

12.1.1

COMMERCIAL OVERHEAD DOOR (CDR)

Hierarchical Level:

Component

System Association:

Exterior

Code:

CDR

Description:

Exterior overhead doors.

Attribute
Component ID

Data Type
Var

Unit
N/A

Domain / Range of Values


System generated unique id for the entity | barcode

SAP ID

Var

N/A

ID used to reference SAP Asset

FSC ID

Var

N/A

Unique id for the entity | CDR.### for the Facility


based upon the FSC naming convention

Component Description

Text

N/A

A narrative description of the entity

Component Type

Combo

N/A

Roll-up, Sectional

System ID

Var

N/A

The system ID that the component is associated to

Criticality

Number

N/A

1, 2, 3, 4, 5

Legacy Names

Var

N/A

Common name or previous name of the entity

Date Entered

Date

N/A

Condition Rating

Number

N/A

System date of when the record was entered into the


database
Condition rating of the component

Inspection Date

Date

N/A

Date of the last inspection for the condition rating

Year Built

Date

N/A

Year that the component was constructed

Design Life

Number

N/A

Design life

Remaining Useful Life

Number

N/A

Remaining useful life estimate

Original Construction
Cost
Replacement Cost

Number

$US

Cost of initial construction or purchase cost

Currency

$US

Current replacement value of the component

Operating Mechanism

Text

N/A

Automatic, Manual

Motion Detection

Integer

N/A

Yes, No

Panic Hardware

Integer

N/A

Yes, No

Warranty Period

Date

N/A

Date of warranty expiration

Manufacturer

Combo

N/A

To be developed on-the-fly

Model Number

Var

N/A

Manufacturers door model number (catalog id)

Serial Number

Var

N/A

Unique identifier for the Component

Width

Number

feet

Width of the door

Height

Number

feet

Height of the door

Grey highlighted fields indicate a field that must contain information.

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-37
02/29/12

DATA DICTIONARY

Attribute
Material

Data Type
Combo

Unit
N/A

Domain / Range of Values


Wood, Metal Grate, Metal Frame and Panels, Metal
Frame with Glass Panels

Motor Voltage

Number

volts

Operating voltage for the motor

Motor Phases

Combo

N/A

1 Phase, 3 Phase

Motor Amps

Number

amps

Current draw for the motor

Motor Horse Power

Number

hp

Motor HP rating

NEMA Designation

Combo

N/A

Drip proof, Splash proof, Totally enclosed fan cooled,


Water proof, Explosion proof

Uniformat Code

Var

N/A

B2034

Grey highlighted fields indicate a field that must contain information.

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-38
02/29/12

DATA DICTIONARY

12.2 INTERIOR FINISHES (INF)

Hierarchical Level:

System

Facility Association:

Terminal

Code:

INF

Description:

Interior finishes for walls, floors and ceilings.

Attribute

Data Type

Unit

Domain / Range of Values

System ID

Var

N/A

System generated unique id for the entity | barcode

SAP ID

Var

N/A

ID used to reference SAP Asset

FSC ID

Var

N/A

Unique id for the entity | INF.### for the Facility based


upon the FSC naming convention

System Description

Text

N/A

A narrative description of the entity

Criticality

Number

N/A

1, 2, 3, 4, 5

Legacy Names

Var

N/A

Common name or previous name of the entity

Date Entered

Date

N/A

Condition Rating

Number

N/A

System date of when the record was entered into the


database
Condition rating of the system

Inspection Date

Date

N/A

Date of the last inspection for the condition rating

Year Built

Date

N/A

Year that the system was constructed

Design Life

Number

N/A

Design life

Remaining Useful Life

Number

N/A

Remaining useful life estimate

Original Construction Cost

Number

$US

Cost of initial construction or purchase cost

Replacement Cost

Currency

$US

Current replacement value of the system

Interior Door,

Number

each

Total number of interior doors

Interior Windows,

Number

SF

Total number of interior windows

Interior Walls, Painted

Number

SF

Total area of painted walls

Interior Walls, Other

Number

SF

Total area of other wall coversings

Flooring Type

Combo

Flooring, qty

Number

SF

Terrazzo, Carpet, VCT, Ceramic Tile, Unfinished, Quarry


Tile, Other
Total area of flooring

Ceiling Type

Combo

Ceiling, qty

Number

SF

Total area of ceiling structure

Campus Location

Combo

N/A

LAX, VNY, ONT, PMD

Address

Var

N/A

Physical address if applicable

Location ID

Var

N/A

GIS Coordinate, Building ID, or other location reference.

Uniformat Code

Var

N/A

C30

Acoustic, Drywall, Concrete, Other

Grey highlighted fields indicate a field that must contain information.

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-39
02/29/12

DATA DICTIONARY

12.3 CONVEYANCE (CVY)

Hierarchical Level:

System

Facility Association:

Terminal

Code:

CVY

Description:

All means of transportation from one floor to another or from one part of a corridor to
another.

Attribute
System ID

Data Type
Var

Unit
N/A

Domain / Range of Values


System generated unique id for the entity | barcode

SAP ID

Var

N/A

ID used to reference SAP Asset

FSC ID

Var

N/A

Unique id for the entity | CVY.### for the Facility based


upon the FSC naming convention

System Description

Text

N/A

A narrative description of the entity

Criticality

Number

N/A

1, 2, 3, 4, 5

Legacy Names

Var

N/A

Common name or previous name of the entity

Date Entered

Date

N/A

Condition Rating

Number

N/A

System date of when the record was entered into the


database
Condition rating of the system

Inspection Date

Date

N/A

Date of the last inspection for the condition rating

Year Built

Date

N/A

Year that the system was constructed

Design Life

Number

N/A

Design life

Remaining Useful Life

Number

N/A

Remaining useful life estimate

Original Construction
Cost
Replacement Cost

Number

$US

Cost of initial construction or purchase cost

Currency

$US

Current replacement value of the system

Warranty

Date

N/A

Date of warranty expiration

Hydraulic Elevators, qty

Number

ea

Number of hydraulic elevators

Traction Elevators, qty

Number

ea

Number of traction style elevators

Escalators, qty

Number

ea

Number of escalators

Moving Walkways, qty

Number

ea

Number of moving walkways

Campus Location

Combo

N/A

LAX, VNY, ONT, PMD

Address

Var

N/A

Physical address if applicable

Location ID

Var

N/A

GIS Coordinate, Building ID, or other location reference.

Uniformat Code

Var

N/A

D10

Grey highlighted fields indicate a field that must contain information.

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-40
02/29/12

DATA DICTIONARY

12.3.1

ELEVATOR (ELV)

Hierarchical Level:

Component

System Association:

Conveyance

Code:

ELV

Description:

An enclosed compartment that is raised or lowered mechanically, used as


transportation between levels in a building.

Attribute

Data Type

Unit

Domain / Range of Values

Component ID

Var

N/A

System generated unique id for the entity | barcode

SAP ID

Var

N/A

ID used to reference SAP Asset

FSC ID

Var

N/A

Unique id for the entity | ELV.### for the Facility


based upon the FSC naming convention

Component Description

Text

N/A

A narrative description of the entity

Component Type

Combo

N/A

Traction, Hydraulic, MRL

System ID

Var

N/A

The system ID that the component is associated to

Criticality

Number

N/A

1, 2, 3, 4, 5

Date Entered

Date

N/A

Condition Rating

Number

N/A

System date of when the record was entered into


the database
Condition rating of the component

Inspection Date

Date

N/A

Date of the last inspection for the condition rating

Year Built

Date

N/A

Year that the component was constructed

Design Life

Number

N/A

Design life

Remaining Useful Life

Number

N/A

Remaining useful life estimate

Original Construction
Cost
Replacement Cost

Number

$US

Cost of initial construction or purchase cost

Currency

$US

Current replacement value of the component

Warranty Period

Date

N/A

Date of warranty expiration

Manufacturer

Combo

N/A

To be developed on-the-fly

Serial Number

Var

N/A

Unique identifier for the Component

State Number

Var

N/A

Unique ID assigned by the state

Use

Combo

N/A

Passenger, Freight, Dumbwaiter

Front and Rear Doors

Integer

N/A

Yes, No

Number Of Floors Served

Number

ea

Number Of Floors Served

Weight Capacity

Number

lbs

Capacity rating

Manufacturer Contract
Number

Var

N/A

Manufacturer Contract Number

Grey highlighted fields indicate a field that must contain information.

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-41
02/29/12

DATA DICTIONARY

Attribute

Data Type

Unit

Domain / Range of Values

Controller Type

Combo

N/A

ACRT, ACVF, DCSS, Hydro

Opening Type

Combo

N/A

Front, Rear, Both

Phone Number

Number

N/A

Phone number of the elevator call-box

Motor Manufacturer

Var

N/A

To be developed on-the-fly

Motor Serial Number

Var

N/A

Unique identifier for the Component

Motor Frame Size

Combo

N/A

Motor Voltage

Number

volts

48, 56, 143, 143T, 145, 145T, 182, 182T, 184,


184T, 203, 204, 213, 213T, 215, 215T, 224, 225,
254, 254U, 254T, 256U, 256T, 284, 284U, 284T,
284TS, 286U, 286T, 286TS, 324, 324U, 324S,
324T, 324TS, 326, 326U, 326S, 326T, 326TS, 364,
364S, 364U, 364US, 364T, 364TS, 365, 365S,
365U, 365US, 365T, 365TS, 404, 404S, 404U,
404US, 404T, 404TS, 405, 405S, 405U, 405US,
405T, 405TS, 444, 444S, 444U, 444US, 444T,
444TS, 445, 445S, 445U, 445US, 445T, 445TS,
447TS, 449TS, 504U, 505, 505S
Operating voltage for the motor

Motor Phases

Combo

N/A

1 Phase, 3 Phase

Motor Amps

Number

amps

Current draw for the motor

Motor Horse Power

Number

hp

Motor HP rating

NEMA Designation

Combo

N/A

Door Operator Type

Combo

N/A

Drip proof, Splash proof, Totally enclosed fan


cooled, Water proof, Explosion proof
Side, Center

Hatch Cab Door Speed

Combo

N/A

one speed, two speed, center opening

Hatch Cab Door Size

Number

sf

Area of the cab door

Hatch Door Opening

Number

N/A

Area of the hatch opening

Governor Rope Diameter

Number

in

Diameter of governor roper

Governor Rope Type

Combo

N/A

Iron, Traction, Extra High Strength Traction

Hoist Type

Combo

N/A

Belt, Rope

Hoist Rope Type

Combo

N/A

Iron, Traction, Extra High Strength Traction

Hoist Rope Diameter

Number

in

Hoist Rope Diameter

Hoist Rope Quantity

Number

ea

Hoist Rope Quantity

Piston Diameter

Number

in

Piston Diameter

Uniformat Code

Var

N/A

D1011 passenger, D1012 freight, D1013 lifts,


D1091 Dumbwaiter

Grey highlighted fields indicate a field that must contain information.

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-42
02/29/12

DATA DICTIONARY

12.3.2

ESCALATOR (ESC)

Hierarchical Level:

Component

System Association:

Conveyance

Code:

ESC

Description:

A set of moving steps, attached to a continuously circulating belt that carries people up
and down levels of a building.

Attribute

Unit

Domain / Range of Values

Component ID

Data
Type
Var

N/A

System generated unique id for the entity | barcode

SAP ID

Var

N/A

ID used to reference SAP Asset

FSC ID

Var

N/A

Unique id for the entity | ESC.### for the Facility


based upon the FSC naming convention

Component Description

Text

N/A

A narrative description of the entity

Component Type

Combo

N/A

System ID

Var

N/A

The system ID that the component is associated to

Criticality

Number

N/A

1, 2, 3, 4, 5

Date Entered

Date

N/A

Condition Rating

Number

N/A

System date of when the record was entered into the


database
Condition rating of the component

Inspection Date

Date

N/A

Date of the last inspection for the condition rating

Year Built

Date

N/A

Year that the component was constructed

Design Life

Number

N/A

Design life

Remaining Useful Life

Number

N/A

Remaining useful life estimate

Original Construction
Cost
Replacement Cost

Number

$US

Cost of initial construction or purchase cost

Currency

$US

Current replacement value of the component

Direction of Travel

Combo

N/A

Up, Down

Width

Number

feet

Width of escalator

Length

Number

feet

Length of escalator

Escalator Rise

Number

feet

Escalator Rise (floor to floor distance)

Warranty Period

Date

N/A

Date of warranty expiration

Manufacturer

Combo

N/A

To be developed on-the-fly

Model Number

Var

N/A

Manufacturers model number (catalog id)

Serial Number

Var

N/A

Unique identifier for the Component

State Number

Var

N/A

Unique ID assigned by the state

Grey highlighted fields indicate a field that must contain information.

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-43
02/29/12

DATA DICTIONARY

Attribute

Data
Type
Text

Unit

Domain / Range of Values

N/A

Manufacturer Contract Number

Text

N/A

ACRT, ACVF, DCSS, Hydro

Step Width

Number

inches

Width of steps

Step Quantity

Number

ea

Number of steps

Step Chain Type

Combo

N/A

2, 4

Step Chain
Manufacturer
Handrail Length

Text

N/A

To be developed on-the-fly

Number

feet

Handrail Length

Handrail Drive Type

Combo

N/A

Sprocket, Helical Pinion Gear, Pulley, Friction

Motor Quantity

Number

ea

Number of motors

Motor Manufacturer

Text

N/A

To be developed on-the-fly

Motor Serial Number

Var

N/A

Unique identifier for the Component

Motor Frame Size

Combo

N/A

Motor Voltage

Number

volts

48, 56, 143, 143T, 145, 145T, 182, 182T, 184, 184T,
203, 204, 213, 213T, 215, 215T, 224, 225, 254, 254U,
254T, 256U, 256T, 284, 284U, 284T, 284TS, 286U,
286T, 286TS, 324, 324U, 324S, 324T, 324TS, 326,
326U, 326S, 326T, 326TS, 364, 364S, 364U, 364US,
364T, 364TS, 365, 365S, 365U, 365US, 365T, 365TS,
404, 404S, 404U, 404US, 404T, 404TS, 405, 405S,
405U, 405US, 405T, 405TS, 444, 444S, 444U,
444US, 444T, 444TS, 445, 445S, 445U, 445US,
445T, 445TS, 447TS, 449TS, 504U, 505, 505S
Operating voltage for the motor

Motor Phases

Combo

N/A

1 Phase, 3 Phase

Motor Amps

Number

amps

Current draw for the motor

Motor Horse Power

Number

hp

Motor HP rating

NEMA Designation

Combo

N/A

Uniformat Code

Var

N/A

Drip proof, Splash proof, Totally enclosed fan cooled,


Water proof, Explosion proof
D1021

Manufacturer Contract
Number
Controller Type

Grey highlighted fields indicate a field that must contain information.

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-44
02/29/12

DATA DICTIONARY

12.3.3

MOVING WALKWAY (MWW)

Hierarchical Level:

Component

System Association:

Conveyance

Code:

MWW

Description:

A moving conveyor belt that serves as transportation over flat or slightly inclined
surfaces and may also be known as a moving sidewalk.

Attribute

Unit

Domain / Range of Values

Component ID

Data
Type
Var

N/A

System generated unique id for the entity | barcode

SAP ID

Var

N/A

ID used to reference SAP Asset

FSC ID

Var

N/A

Unique id for the entity | MWW.### for the Facility based


upon the FSC naming convention

Component Description

Text

N/A

A narrative description of the entity

Component Type

Combo

N/A

System ID

Var

N/A

The system ID that the component is associated to

Criticality

Number

N/A

1, 2, 3, 4, 5

Date Entered

Date

N/A

Condition Rating

Number

N/A

System date of when the record was entered into the


database
Condition rating of the component

Inspection Date

Date

N/A

Date of the last inspection for the condition rating

Year Built

Date

N/A

Year that the component was constructed

Design Life

Number

N/A

Design life

Remaining Useful Life

Number

N/A

Remaining useful life estimate

Original Construction
Cost
Replacement Cost

Number

$US

Cost of initial construction or purchase cost

Currency

$US

Current replacement value of the component

Direction of Travel

Combo

N/A

Up, Down

Width

Number

feet

Width of escalator

Length

Number

feet

Length of escalator

Escalator Rise

Number

feet

Escalator Rise (floor to floor distance)

Warranty Period

Date

N/A

Date of warranty expiration

Manufacturer

Combo

N/A

To be developed on-the-fly

Model Number

Var

N/A

Manufacturers model number (catalog id)

Serial Number

Var

N/A

Unique identifier for the Component

State Number

Var

N/A

Unique ID assigned by the state

Grey highlighted fields indicate a field that must contain information.

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-45
02/29/12

DATA DICTIONARY

Attribute

Data
Type
Text

Unit

Domain / Range of Values

N/A

Manufacturer Contract Number

Text

N/A

ACRT, ACVF, DCSS, Hydro

Step Width

Number

inches

Width of steps

Step Quantity

Number

ea

Number of steps

Step Chain Type

Combo

N/A

2, 4

Step Chain
Manufacturer
Handrail Length

Text

N/A

To be developed on-the-fly

Number

feet

Handrail Length

Handrail Drive Type

Combo

N/A

Sprocket, Helical Pinion Gear, Pulley, Friction

Motor Quantity

Number

ea

Number of motors

Motor Manufacturer

Text

N/A

To be developed on-the-fly

Motor Serial Number

Var

N/A

Unique identifier for the Component

Motor Frame Size

Combo

N/A

Motor Voltage

Number

volts

48, 56, 143, 143T, 145, 145T, 182, 182T, 184, 184T,
203, 204, 213, 213T, 215, 215T, 224, 225, 254, 254U,
254T, 256U, 256T, 284, 284U, 284T, 284TS, 286U,
286T, 286TS, 324, 324U, 324S, 324T, 324TS, 326,
326U, 326S, 326T, 326TS, 364, 364S, 364U, 364US,
364T, 364TS, 365, 365S, 365U, 365US, 365T, 365TS,
404, 404S, 404U, 404US, 404T, 404TS, 405, 405S,
405U, 405US, 405T, 405TS, 444, 444S, 444U, 444US,
444T, 444TS, 445, 445S, 445U, 445US, 445T, 445TS,
447TS, 449TS, 504U, 505, 505S
Operating voltage for the motor

Motor Phases

Combo

N/A

1 Phase, 3 Phase

Motor Amps

Number

amps

Current draw for the motor

Motor Horse Power

Number

hp

Motor HP rating

NEMA Designation

Combo

N/A

Uniformat Code

Var

N/A

Drip proof, Splash proof, Totally enclosed fan cooled,


Water proof, Explosion proof
D1022

Manufacturer Contract
Number
Controller Type

Grey highlighted fields indicate a field that must contain information.

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-46
02/29/12

DATA DICTIONARY

12.4 ELECTRICAL SERVICE AND DISTRIBUTION (ESD)

Hierarchical Level:

System

Facility Association:

Central Utility Plant

Code:

ESD

Description:

Electrical service and distribution.

Attribute
System ID

Data Type
Var

Unit
N/A

Domain / Rang of Values


System generated unique id for the entity | barcode

SAP ID

Var

N/A

ID used to reference SAP Asset

FSC ID

Var

N/A

Unique id for the entity | ESD.### for the Facility


based upon the FSC naming convention

System Description

Text

N/A

Date Entered

Date

N/A

Condition Rating

Number

N/A

Condition rating of the system

Inspection Date

Date

N/A

Date of the last inspection for the condition rating

Year Built

Date

N/A

Year that the system was constructed

Design Life

Number

N/A

Design life

Remaining Useful Life

Number

N/A

Remaining useful life estimate

Original Construction Cost

Number

$US

Cost of initial construction or purchase cost

Replacement Cost

Currency

$US

Current replacement value of the system

Replacement Year

Date

N/A

Warranty Period

Date

N/A

Location ID

Var

N/A

Uniformat Code

Var

N/A

GIS Coordinate, Building ID, or other location


reference.
D5010

Grey highlighted fields indicate a field that must contain information.

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-47
02/29/12

DATA DICTIONARY

12.5 ELECTRICAL (ELC)

Hierarchical Level:

System

Facility Association:

Terminal

Code:

ELC

Description:

Equipment used to generate, transmit, transform and distribute electric energy or


power.

Attribute

Data Type

Unit

Domain / Range of Values

System ID

Var

N/A

System generated unique id for the entity | barcode

SAP ID
FSC ID

Var
Var

N/A
N/A

System Description
Criticality
Legacy Names
Date Entered

Text
Number
Var
Date

N/A
N/A
N/A
N/A

Condition Rating

Number

N/A

ID used to reference SAP Asset


Unique id for the entity | ELC.### for the Facility
based upon the FSC naming convention
A narrative description of the entity
1, 2, 3, 4, 5
Common name or previous name of the entity
System date of when the record was entered into the
database
Condition rating of the system

Inspection Date

Date

N/A

Date of the last inspection for the condition rating

Year Built

Date

N/A

Year that the system was constructed

Design Life

Number

N/A

Design life

Remaining Useful Life

Number

N/A

Remaining useful life estimate

Original Construction
Cost
Replacement Cost

Number

$US

Cost of initial construction or purchase cost

Currency

$US

Current replacement value of the system

Warranty Period
Generators, qty
Distribution Panels, qty

Date
Number
Number

N/A
ea
ea

Major Transformers, qty

Number

ea

Date of warranty expiration


Number of electrical generators
Number of distribution Main & Major Distribution
Panels
Number of transformers

Campus Location

Combo

N/A

LAX, VNY, ONT, PMD

Address

Var

N/A

Physical address if applicable

Location ID

Var

N/A

Uniformat Code

Var

N/A

GIS Coordinate, Building ID, or other location


reference.
D50

Grey highlighted fields indicate a field that must contain information.

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-48
02/29/12

DATA DICTIONARY

12.5.1

GENERATOR (GEN)

Hierarchical Level:

Component

System Association:

Electrical

Code:

GEN

Description:

Device used to convert mechanical energy into electricity.

Attribute
Component ID
SAP ID

Data Type
Var
Var

Unit
N/A
N/A

Domain / Range of Values


System generated unique id for the entity | barcode

FSC ID

Var

N/A

Unique id for the entity | GEN.### for the Facility


based upon the FSC naming convention

Component Description

Text

N/A

A narrative description of the entity

Component Type
System ID
Criticality

Combo
Var
Number

N/A
N/A
N/A

AC, DC
The system ID that the component is associated to
1, 2, 3, 4, 5

Legacy Names

Var

N/A

Common name or previous name of the entity

Date Entered

Date

N/A

Condition Rating

Number

N/A

System date of when the record was entered into


the database
Condition rating of the component

Inspection Date

Date

N/A

Date of the last inspection for the condition rating

Year Built

Date

N/A

Year that the component was constructed

Design Life

Number

N/A

Design life

Remaining Useful Life

Number

N/A

Remaining useful life estimate

Original Construction
Cost
Replacement Cost

Number

$US

Cost of initial construction or purchase cost

Currency

$US

Current replacement value of the component

Warranty Period

Date

N/A

Date of warranty expiration

Manufacturer

Combo

N/A

To be developed on-the-fly

Serial Number

Var

N/A

Unique identifier for the Component

Model Number
Fuel Type
Kilowatts
Voltage
Phase
Uniformat Code

Var
Combo
Number
Combo
Combo
Var

N/A
N/A
KVA
N/A
N/A
N/A

Manufacturers door model number (catalog id)


Gasoline, Diesel, Propane, Other
Total generator capacity
120/208, 120/240, 277/480, 2400/4160
1 Phase, 3 Phase
D5092

ID used to reference SAP Asset

Grey highlighted fields indicate a field that must contain information.

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-49
02/29/12

DATA DICTIONARY

12.5.2

DISTRIBUTION PANEL (EDP)

Hierarchical Level:

Component

System Association:

Electrical

Code:

EDP

Description:

An electric panel used to distribute electricity within a building.

Attribute
Component ID

Data Type
Var

Unit
N/A

Domain / Range of Values


System generated unique id for the entity | barcode

SAP ID

Var

N/A

ID used to reference SAP Asset

FSC ID

Var

N/A

Unique id for the entity | EDP.### for the Facility


based upon the FSC naming convention

Component Description

Text

N/A

A narrative description of the entity

System ID

Var

N/A

The system ID that the component is associated to

Criticality

Number

N/A

1, 2, 3, 4, 5

Legacy Names

Var

N/A

Common name or previous name of the entity

Date Entered

Date

N/A

Condition Rating

Number

N/A

System date of when the record was entered into


the database
Condition rating of the component

Inspection Date

Date

N/A

Date of the last inspection for the condition rating

Year Built

Date

N/A

Year that the component was constructed

Design Life

Number

N/A

Design life

Remaining Useful Life

Number

N/A

Remaining useful life estimate

Original Construction
Cost
Replacement Cost

Number

$US

Cost of initial construction or purchase cost

Currency

$US

Current replacement value of the component

Voltage

Number

Volts

Panel voltage 120, 240

Current Capacity Rating

Number

Amps

Current rating

Manufacturer

Combo

N/A

To be developed on-the-fly

Breaker Switches, qty

Number

ea

Number of breaker switches installed

Spares, qty

Number

ea

Number of spare slots

Spaces, qty

Number

ea

Total quantity of breaker spaces

Uniformat Code

Var

N/A

D5012

Grey highlighted fields indicate a field that must contain information.

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-50
02/29/12

DATA DICTIONARY

12.5.3

TRANSFORMER (TNF)

Hierarchical Level:

Component

System Association:

Electrical

Code:

TNF

Description:

A device that transfers electrical energy from one alternating circuit to another with a
change in voltage, current, phase, or impedance.

Attribute

Data Type

Unit

Domain / Range of Values

Component ID

Var

N/A

System generated unique id for the entity | barcode

SAP ID

Var

N/A

ID used to reference SAP Asset

FSC ID

Var

N/A

Unique id for the entity | TNF.### for the Facility


based upon the FSC naming convention

Component Description

Text

N/A

A narrative description of the entity

Component Type

Combo

N/A

Roll-up, Sectional

System ID

Var

N/A

The system ID that the component is associated to

Criticality

Number

N/A

1, 2, 3, 4, 5

Legacy Names

Var

N/A

Common name or previous name of the entity

Date Entered

Date

N/A

Condition Rating

Number

N/A

System date of when the record was entered into


the database
Condition rating of the component

Inspection Date

Date

N/A

Date of the last inspection for the condition rating

Year Built

Date

N/A

Year that the component was constructed

Design Life

Number

N/A

Design life

Remaining Useful Life

Number

N/A

Remaining useful life estimate

Original Construction
Cost
Replacement Cost

Number

$US

Cost of initial construction or purchase cost

Currency

$US

Current replacement value of the component

Manufacturer

Combo

N/A

To be developed on-the-fly

Mounting

Combo

N/A

Floor, Wall/Ceiling, Grade

High Side Voltage

Number

Volts

High side voltage

Low Side Voltage

Number

Volts

Low side voltage

Current Capacity Rating

Number

Amps

Current capacity rating

Uniformat Code

Var

N/A

D5011

Grey highlighted fields indicate a field that must contain information.

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-51
02/29/12

DATA DICTIONARY

12.5.4

SWITCHBOARD (SWB)

Hierarchical Level:

Component

System Association:

Electrical

Code:

SWB

Description:

Insulating panels containing electrical devices such as switches, circuit breakers, fuses
and meters required to operate electrical equipment.

Attribute

Data Type

Unit

Domain / Range of Values

Component ID

Var

N/A

System generated unique id for the entity | barcode

SAP ID

Var

N/A

ID used to reference SAP Asset

FSC ID

Var

N/A

Unique id for the entity | SWB.### for the Facility


based upon the FSC naming convention

Component Description

Text

N/A

A narrative description of the entity

System ID

Var

N/A

The system ID that the component is associated to

Criticality

Number

N/A

1, 2, 3, 4, 5

Legacy Names

Var

N/A

Common name or previous name of the entity

Date Entered

Date

N/A

Condition Rating

Number

N/A

System date of when the record was entered into


the database
Condition rating of the component

Inspection Date

Date

N/A

Date of the last inspection for the condition rating

Year Built

Date

N/A

Year that the component was constructed

Design Life

Number

N/A

Design life

Remaining Useful Life

Number

N/A

Remaining useful life estimate

Original Construction
Cost
Replacement Cost

Number

$US

Cost of initial construction or purchase cost

Currency

$US

Current replacement value of the component

Manufacturer

Combo

N/A

To be developed on-the-fly

Mounting

Combo

N/A

Floor, Wall/Ceiling, Grade

Voltage

Number

Volts

Voltage

Current Capacity Rating

Number

Amps

Current Capacity Rating

Switches, qty

Number

ea

Number of switches

Spares, qty

Number

ea

Number of spare slots

Spaces, qty

Number

ea

Total quantity of spaces

Uniformat Code

Var

N/A

D5021

Grey highlighted fields indicate a field that must contain information.

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-52
02/29/12

DATA DICTIONARY

12.5.5

MOTOR CONTROL CENTER (MCC)

Hierarchical Level:

Component

System Association:

Electrical

Code:

MCC

Description:

A device or group of devices that serves to govern in some predetermined manner the
performance of an electric motor. A motor controller might include a manual or
automatic means for starting and stopping the motor, selecting forward or reverse
rotation, selecting and regulating the speed, regulating or limiting the torque, and
protecting against overloads and faults.

Attribute

Data Type

Unit

Domain / Range of Values

Component ID

Var

N/A

System generated unique id for the entity | barcode

SAP ID

Var

N/A

ID used to reference SAP Asset

FSC ID

Var

N/A

Unique id for the entity | SWB.### for the Facility


based upon the FSC naming convention

Component Description

Text

N/A

A narrative description of the entity

System ID

Var

N/A

The system ID that the component is associated to

Criticality

Number

N/A

1, 2, 3, 4, 5

Legacy Names

Var

N/A

Common name or previous name of the entity

Date Entered

Date

N/A

Condition Rating

Number

N/A

System date of when the record was entered into


the database
Condition rating of the component

Inspection Date

Date

N/A

Date of the last inspection for the condition rating

Year Built

Date

N/A

Year that the component was constructed

Design Life

Number

N/A

Design life

Remaining Useful Life

Number

N/A

Remaining useful life estimate

Original Construction
Cost
Replacement Cost

Number

$US

Cost of initial construction or purchase cost

Currency

$US

Current replacement value of the component

Manufacturer

Combo

N/A

To be developed on-the-fly

Voltage

Number

Volts

Voltage

Current Capacity Rating

Number

Amps

Current Capacity Rating

Switches, qty

Number

ea

Number of switches

Spares, qty

Number

ea

Number of spare slots

Spaces, qty

Number

ea

Total quantity of spaces

Uniformat Code

Var

N/A

D5013

Grey highlighted fields indicate a field that must contain information.

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-53
02/29/12

DATA DICTIONARY

12.6 FIRE PROTECTION (FPS)

Hierarchical Level:

System

Facility Association:

Terminal

Code:

FPS

Description:

Equipment used to mitigate and protect against the unwanted effects of fire.

Attribute

Data Type

Unit

Domain / Range of Values

System ID

Var

N/A

System generated unique id for the entity | barcode

SAP ID
FSC ID

Var
Var

N/A
N/A

System Description
System Type

Text
Combo

N/A
N/A

ID used to reference SAP Asset


Unique id for the entity | FPS.### for the Facility
based upon the FSC naming convention
A narrative description of the entity
Wet pipe, dry pipe, halon, CO2,

Criticality
Legacy Names
Date Entered

Number
Var
Date

N/A
N/A
N/A

Condition Rating

Number

N/A

1, 2, 3, 4, 5
Common name or previous name of the entity
System date of when the record was entered into
the database
Condition rating of the system

Inspection Date

Date

N/A

Date of the last inspection for the condition rating

Year Built

Date

N/A

Year that the system was constructed

Design Life

Number

N/A

Design life

Remaining Useful Life

Number

N/A

Remaining useful life estimate

Original Construction Cost

Number

$US

Cost of initial construction or purchase cost

Replacement Cost

Currency

$US

Current replacement value of the system

Warranty Period
Manufacturer

Date
Combo

N/A
N/A

Date of warranty expiration


To be developed on-the-fly

Area Covered

Var

N/A

Full, Partial

Is Fire Suppression
included as a part of this
system?
Is a Fire alarm included as
a part of this system?

Integer

Yes,

Is Fire Suppression included as a part of this


system?

Campus Location

Combo

N/A

LAX, VNY, ONT, PMD

Address

Var

N/A

Physical address if applicable

Location ID

Var

N/A

Uniformat Code

Var

N/A

GIS Coordinate, Building ID, or other location


reference.
D40

No
Integer

Yes,

Is a Fire alarm included as a part of this system?

No

Grey highlighted fields indicate a field that must contain information.

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-54
02/29/12

DATA DICTIONARY

12.6.1

FIRE ALARM CONTROL PANEL (FCP)

Hierarchical Level:

Component

System Association:

Fire Protection

Code:

FCP

Description:

An electrical panel that is the controlling component of a fire protection system.

Attribute
Component ID
SAP ID

Data Type
Var
Var

Unit
N/A
N/A

Domain / Range of Values


System generated unique id for the entity | barcode

FSC ID

Var

N/A

Unique id for the entity | FCP.### for the Facility


based upon the FSC naming convention

System Description

Text

N/A

A narrative description of the entity

Component Type

Combo

N/A

System ID
Criticality

Var
Number

N/A
N/A

Multiplex, Addressable, Releasing, Conventional,


Coded
The system ID that the component is associated to
1, 2, 3, 4, 5

Legacy Names

Var

N/A

Common name or previous name of the entity

Date Entered

Date

N/A

Condition Rating

Number

N/A

System date of when the record was entered into


the database
Condition rating of the component

Inspection Date

Date

N/A

Date of the last inspection for the condition rating

Year Built

Date

N/A

Year that the component was constructed

Design Life

Number

N/A

Design life

Remaining Useful Life

Number

N/A

Remaining useful life estimate

Original Construction
Cost
Replacement Cost

Number

$US

Cost of initial construction or purchase cost

Currency

$US

Current replacement value of the component

Warranty Period

Date

N/A

Date of warranty expiration

Manufacturer

Combo

N/A

To be developed on-the-fly

Serial Number

Var

N/A

Unique identifier for the Component

Model Number
Number Of Zones

Var
Number

N/A
ea

Manufacturers door model number (catalog id)


Number Of Zones covered

Uniformat Code

Var

N/A

D5037

ID used to reference SAP Asset

Grey highlighted fields indicate a field that must contain information.

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-55
02/29/12

DATA DICTIONARY

12.7 HEAT GENERATING SYSTEM (HGS)

Hierarchical Level:

System

Facility Association:

Central Utility Plant

Code:

HGS

Description:

Heat generating system.

Attribute
System ID

Data Type
Var

Unit
N/A

Domain / Range of Values


System generated unique id for the entity | barcode

SAP ID

Var

N/A

ID used to reference SAP Asset

FSC ID

Var

N/A

Unique id for the entity | HGS.### for the Facility


based upon the FSC naming convention

System Description

Text

N/A

Legacy Names

Var

N/A

Date Entered

Date

N/A

Condition Rating

Number

N/A

Condition rating of the system

Inspection Date

Date

N/A

Date of the last inspection for the condition rating

Year Built

Date

N/A

Year that the system was constructed

Design Life

Number

N/A

Design life

Remaining Useful Life

Number

N/A

Remaining useful life estimate

Original Construction Cost

Number

$US

Cost of initial construction or purchase cost

Replacement Cost

Currency

$US

Current replacement value of the system

Installation Year

Date

N/A

Warranty Period

Date

N/A

Rating

Number

MBTU

Uniformat Code

Var

N/A

Common name or previous name of the entity

D3020

Grey highlighted fields indicate a field that must contain information.

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-56
02/29/12

DATA DICTIONARY

12.8 COOLING GENERATING SYSTEM (CGS)

Hierarchical Level:

System

Facility Association:

Central Utility Plant

Code:

CGS

Description:

Cooling generating system.

Attribute
System ID

Data Type
Var

Unit
N/A

Domain / Range of Values


System generated unique id for the entity | barcode

SAP ID

Var

N/A

ID used to reference SAP Asset

FSC ID

Var

N/A

Unique id for the entity | CGS.### for the Facility


based upon the FSC naming convention

System Description

Text

N/A

Legacy Names

Var

N/A

Date Entered

Date

N/A

Condition Rating

Number

N/A

Condition rating of the system

Inspection Date

Date

N/A

Date of the last inspection for the condition rating

Year Built

Date

N/A

Year that the system was constructed

Design Life

Number

N/A

Design life

Remaining Useful Life

Number

N/A

Remaining useful life estimate

Original Construction Cost

Number

$US

Cost of initial construction or purchase cost

Replacement Cost

Currency

$US

Current replacement value of the system

Warranty Period

Date

N/A

Rating

Number

Tons

Uniformat Code

Var

N/A

Common name or previous name of the entity

D3030

Grey highlighted fields indicate a field that must contain information.

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-57
02/29/12

DATA DICTIONARY

12.9 HVAC (HVA)

Hierarchical Level:

System

Facility Association:

Terminal

Code:

HVA

Description:

Heating, ventilation and air conditioning equipment.

Attribute
System ID

Data Type
Var

Unit
N/A

Domain / Range of Values


System generated unique id for the entity | barcode

SAP ID
FSC ID

Var
Var

N/A
N/A

System Description
Criticality
Legacy Names
Date Entered

Text
Number
Var
Date

N/A
N/A
N/A
N/A

Condition Rating
Last Inspection Date
Year Built
Design Life
Remaining Useful Life
Original Construction Cost
Replacement Cost
Warranty Period
Air Handling Units, qty

Number
Date
Date
Number
Number
Number
Currency
Date
Number

N/A
N/A
N/A
N/A
N/A
$US
$US
N/A
ea

ID used to reference SAP Asset


Unique id for the entity | HVA.### for the Facility based
upon the FSC naming convention
A narrative description of the entity
1, 2, 3, 4, 5
Common name or previous name of the entity
System date of when the record was entered into the
database
Condition rating of the system
Date of last inspection for the condition rating
Year that the system was constructed
Design life
Remaining useful life estimate
Cost of initial construction or purchase cost
Current replacement value of the system
Date of warranty expiration
Number of air handling units

Condensing Units, qty

Number

ea

Number of condensing units

Heat Exchangers, qty

Number

ea

Number of heat exchanges

VFDs, qty

Number

ea

Number of variable frequency drives

Vehicle Exhaust Removal


Systems, qty
Boilers, qty

Number

ea

Number of vehicle exhaust systems

Number

ea

Number of boilers

Chillers, qty

Number

ea

Number of chillers

Cooling Towers, qty

Number

ea

Number of cooling towers

Furnaces, qty

Number

ea

Number of furnaces

Packaged Unit, qty

Number

ea

Number of packaged units

Supply Fans, qty

Number

ea

Number of supply fans

Campus Location

Combo

Address

Var

N/A

Physical address if applicable

Location ID

Var

N/A

GIS Coordinate, Building ID, or other location reference.

Uniformat Code

Var

N/A

D30

LAX, VNY, ONT, PMD

Grey highlighted fields indicate a field that must contain information.

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-58
02/29/12

DATA DICTIONARY

12.9.1

AIR HANDLING UNIT (AHU)

Hierarchical Level:

Component

System Association:

HVAC

Code:

AHU

Description:

A packaged assembly of air-conditioning equipment, such as coils, filters, humidifiers


etc., which provide the treatment of air before it is distributed.

Attribute
Component ID

Data Type
Var

Unit
N/A

Domain / Range of Values


System generated unique id for the entity | barcode

SAP ID

Var

N/A

ID used to reference SAP Asset

FSC ID

Var

N/A

Unique id for the entity | AHU.### for the Facility


based upon the FSC naming convention

Component Description

Text

N/A

A narrative description of the entity

Component Type

Combo

N/A

Single Zone, Multi Zone

System ID
Criticality

Var
Number

N/A
N/A

The system ID that the component is associated to


1, 2, 3, 4, 5

Legacy Names

Var

N/A

Common name or previous name of the entity

Date Entered

Date

N/A

Condition Rating

Number

N/A

System date of when the record was entered into


the database
Condition rating of the component

Inspection Date

Date

N/A

Date of the last inspection for the condition rating

Year Built

Date

N/A

Year that the component was constructed

Design Life

Number

N/A

Design life

Remaining Useful Life

Number

N/A

Remaining useful life estimate

Original Construction Cost

Number

$US

Cost of initial construction or purchase cost

Replacement Cost

Currency

$US

Current replacement value of the component

Warranty Period

Date

N/A

Date of warranty expiration

Manufacturer

Combo

N/A

To be developed on-the-fly

Serial Number

Var

N/A

Unique identifier for the Component

Model Number
Has Cooling Coils

Var
Integer

N/A
Yes,

Manufacturers door model number (catalog id)


Does the unit of cooling coils?

No
Has Heating Coils

Integer

Yes,

Does the unit of heating coils?

No

Heat System Type

Combo

N/A

None, Electric, Steam, Hot Fluid

Number Of VAV Boxes

Number

ea

Number Of VAV Boxes

Grey highlighted fields indicate a field that must contain information.

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-59
02/29/12

DATA DICTIONARY

Attribute
CFM

Data Type
Number

Unit
cfm

Domain / Range of Values


Volume of air flow

Tonnage

Number

tons

Cooling rating

BTU

Number

btu

Heating rating

Motor Manufacturer

Text

N/A

To be developed on-the-fly

Motor Serial Number

Var

N/A

Unique identifier for the Component

Motor Frame Size

Combo

N/A

Motor Voltage

Number

volts

48, 56, 143, 143T, 145, 145T, 182, 182T, 184,


184T, 203, 204, 213, 213T, 215, 215T, 224, 225,
254, 254U, 254T, 256U, 256T, 284, 284U, 284T,
284TS, 286U, 286T, 286TS, 324, 324U, 324S,
324T, 324TS, 326, 326U, 326S, 326T, 326TS, 364,
364S, 364U, 364US, 364T, 364TS, 365, 365S,
365U, 365US, 365T, 365TS, 404, 404S, 404U,
404US, 404T, 404TS, 405, 405S, 405U, 405US,
405T, 405TS, 444, 444S, 444U, 444US, 444T,
444TS, 445, 445S, 445U, 445US, 445T, 445TS,
447TS, 449TS, 504U, 505, 505S
Operating voltage for the motor

Motor Phases

Combo

N/A

1 Phase, 3 Phase

Motor Amps

Number

amps

Current draw for the motor

Motor Horse Power

Number

hp

Motor HP rating

NEMA Designation

Combo

N/A

Uniformat Code

Var

N/A

Drip proof, Splash proof, Totally enclosed fan


cooled, Water proof, Explosion proof
D3052

Grey highlighted fields indicate a field that must contain information.

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-60
02/29/12

DATA DICTIONARY

12.9.2

CONDENSING UNIT (CDN)

Hierarchical Level:

Component

System Association:

HVAC

Code:

CDN

Description:

The exterior component of a cooling system that includes a compressor and


condensing coil.

Attribute
Component ID

Data Type
Var

Unit
N/A

Domain / Range of Values


System generated unique id for the entity | barcode

SAP ID

Var

N/A

ID used to reference SAP Asset

FSC ID

Var

N/A

Unique id for the entity | CDN.### for the Facility


based upon the FSC naming convention

Component Description

Text

N/A

A narrative description of the entity

System ID
Criticality

Var
Number

N/A
N/A

The system ID that the component is associated to


1, 2, 3, 4, 5

Legacy Names

Var

N/A

Common name or previous name of the entity

Date Entered

Date

N/A

Condition Rating

Number

N/A

System date of when the record was entered into the


database
Condition rating of the component

Inspection Date

Date

N/A

Date of the last inspection for the condition rating

Year Built

Date

N/A

Year that the component was constructed

Design Life

Number

N/A

Design life

Remaining Useful Life

Number

N/A

Remaining useful life estimate

Original Construction Cost

Number

$US

Cost of initial construction or purchase cost

Replacement Cost

Currency

$US

Current replacement value of the component

Warranty Period

Date

N/A

Date of warranty expiration

Manufacturer

Combo

N/A

To be developed on-the-fly

Serial Number

Var

N/A

Unique identifier for the Component

Model

Var

N/A

Manufacturers door model number (catalog id)

Cooling Type

Combo

N/A

Air cooled, Water cooled

Tonnage

Number

tons

Capacity of condenser

Uniformat Code

Var

N/A

D3032

Grey highlighted fields indicate a field that must contain information.

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-61
02/29/12

DATA DICTIONARY

12.9.3

EXHAUST FAN (EXF)

Hierarchical Level:

Component

System Association:

HVAC

Code:

EXF

Description:

A fan for ventilating an enclosed space by moving air from the interior to the exterior of
a building.

Attribute
Component ID

Data Type
Var

Unit
N/A

Domain / Range of Values


System generated unique id for the entity | barcode

SAP ID

Var

N/A

ID used to reference SAP Asset

FSC ID

Var

N/A

Unique id for the entity | EXF.### for the Facility


based upon the FSC naming convention

Component Description

Text

N/A

A narrative description of the entity

Component Type

Combo

N/A

axial, centrifugal, propeller, utility

System ID

Var

N/A

The system ID that the component is associated to

Criticality

Number

N/A

1, 2, 3, 4, 5

Legacy Names

Var

N/A

Common name or previous name of the entity

Date Entered

Date

N/A

Condition Rating

Number

N/A

System date of when the record was entered into


the database
Condition rating of the component

Inspection Date

Date

N/A

Date of the last inspection for the condition rating

Year Built

Date

N/A

Year that the component was constructed

Design Life

Number

N/A

Design life

Remaining Useful Life

Number

N/A

Remaining useful life estimate

Original Construction Cost

Number

$US

Cost of initial construction or purchase cost

Replacement Cost

Currency

$US

Current replacement value of the component

CFM

Number

cfm

Air flow volume (design)

Use

Combo

N/A

Exhaust, Supply

Mount Type

Combo

N/A

Motor Manufacturer

Text

N/A

anti-vibration, base mount, close coupled, flange


mounted, horizontal mount, in-line mount, roof
mount, suspended, vertical mount, wall mount,
floor mounted, wall mounted
To be developed on-the-fly

Motor Serial Number

Var

N/A

Unique identifier for the motor

Motor Frame Size

Combo

N/A

48, 56, 143, 143T, 145, 145T, 182, 182T, 184,


184T, 203, 204, 213, 213T, 215, 215T, 224, 225,
254, 254U, 254T, 256U, 256T, 284, 284U, 284T,
284TS, 286U, 286T, 286TS, 324, 324U, 324S,

Grey highlighted fields indicate a field that must contain information.

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-62
02/29/12

DATA DICTIONARY

Attribute

Data Type

Unit

Motor Voltage

Number

volts

Domain / Range of Values


324T, 324TS, 326, 326U, 326S, 326T, 326TS, 364,
364S, 364U, 364US, 364T, 364TS, 365, 365S,
365U, 365US, 365T, 365TS, 404, 404S, 404U,
404US, 404T, 404TS, 405, 405S, 405U, 405US,
405T, 405TS, 444, 444S, 444U, 444US, 444T,
444TS, 445, 445S, 445U, 445US, 445T, 445TS,
447TS, 449TS, 504U, 505, 505S
Operating voltage for the motor

Motor Phases

Combo

N/A

1 Phase, 3 Phase

Motor Amps

Number

amps

Current draw for the motor

Motor Horse Power

Number

hp

Motor HP rating

NEMA Designation

Combo

N/A

Uniformat Code

Var

N/A

Drip proof, Splash proof, Totally enclosed fan


cooled, Water proof, Explosion proof
D3042

Grey highlighted fields indicate a field that must contain information.

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-63
02/29/12

DATA DICTIONARY

12.10 MECHANICAL (MEC)

Hierarchical Level:

System

Facility Association:

Terminal

Code:

MEC

Description:

A collection of components such as blowers, pump, compressors and controllers that


distributes utilities to facilities.

Attribute
System ID

Data Type
Var

Unit
N/A

Domain / Range of Values


System generated unique id for the entity | barcode

SAP ID
FSC ID

Var
Var

N/A
N/A

System Description
System Type

Text
Combo

N/A
N/A

Legacy Names
Date Entered

Var
Date

N/A
N/A

Condition Rating
Last Inspection Date
Year Built
Design Life
Remaining Useful Life
Original Construction Cost
Replacement Cost
Warranty Period
Air Compressors, qty

Number
Date
Date
Number
Number
Number
Currency
Date
Number

N/A
N/A
N/A
N/A
N/A
$US
$US
N/A
ea

ID used to reference SAP Asset


Unique id for the entity | MEC.### for the Facility
based upon the FSC naming convention
A narrative description of the entity
Steam distribution, Air distribution, Hot water
distribution, Chilled water distribution
Common name or previous name of the entity
System date of when the record was entered into
the database
Condition rating of the system
Date of last inspection for the condition rating
Year that the system was constructed
Design life
Remaining useful life estimate
Cost of initial construction or purchase cost
Current replacement value of the system
Date of warranty expiration
Number of air compressors

Air Drier, qty

Number

ea

Number of air driers

Gas Compressors, qty

Number

ea

Number of gas compressors

Gas Turbine Compressors,


qty
Campus Location

Number

ea

Number of gas turbines

Address

Var

N/A

Physical address if applicable

Location ID

Var

N/A

Uniformat Code

Var

N/A

GIS Coordinate, Building ID, or other location


reference.
D3040

Combo

LAX, VNY, ONT, PMD

Grey highlighted fields indicate a field that must contain information.

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-64
02/29/12

DATA DICTIONARY

12.10.1

COMPRESSOR (CMP)

Hierarchical Level:

Component

System Association:

Mechanical

Code:

CMP

Description:

A machine that compresses gas so that the power produced when the gas is released
can be used to power another machine.

Attribute
Component ID

Data Type
Var

Unit
N/A

Domain / Range of Values


System generated unique id for the entity | barcode

SAP ID

Var

N/A

ID used to reference SAP Asset

FSC ID

Var

N/A

Component Description

Text

N/A

Unique id for the entity | CMP.### for the Facility


based upon the FSC naming convention
A narrative description of the entity

Component Type

Combo

N/A

System ID
Criticality

Var
Number

N/A
N/A

Reciprocating, Rotary Screw, Rotary vane, Scroll,


Diaphragm, Axial-flow, Centrifugal, Mixed-flow
The system ID that the component is associated to
1, 2, 3, 4, 5

Legacy Names

Var

N/A

Common name or previous name of the entity

Date Entered

Date

N/A

Condition Rating

Number

N/A

System date of when the record was entered into the


database
Condition rating of the component

Inspection Date

Date

N/A

Date of the last inspection for the condition rating

Year Built

Date

N/A

Year that the component was constructed

Design Life

Number

N/A

Design life

Remaining Useful Life

Number

N/A

Remaining useful life estimate

Original Construction Cost

Number

$US

Cost of initial construction or purchase cost

Replacement Cost

Currency

$US

Current replacement value of the component

Warranty Period

Date

N/A

Date of warranty expiration

Manufacturer

Combo

N/A

To be developed on-the-fly

Serial Number

Var

N/A

Unique identifier for the Component

Model Number

Var

N/A

Manufacturers door model number (catalog id)

Warranty Period

Date

N/A

Date of warranty expiration

Application

Combo

N/A

HVAC, Fire Protection

Has Air Drier?

Integer

N/A

Yes, No

Air Control Type

Combo

N/A

Dual, Single

Maximum Pressure

Number

psi

Maximum Pressure

Grey highlighted fields indicate a field that must contain information.

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-65
02/29/12

DATA DICTIONARY

Attribute
Tank Size

Data Type
Number

Unit
gallons

Domain / Range of Values


Tank Size

Cooling Method

Combo

N/A

Air, Water, Oil

Motor Manufacturer

Text

N/A

To be developed on-the-fly

Motor Serial Number

Var

N/A

Unique identifier for the Component

Motor Frame Size

Combo

N/A

Motor Voltage

Number

volts

48, 56, 143, 143T, 145, 145T, 182, 182T, 184, 184T,
203, 204, 213, 213T, 215, 215T, 224, 225, 254,
254U, 254T, 256U, 256T, 284, 284U, 284T, 284TS,
286U, 286T, 286TS, 324, 324U, 324S, 324T, 324TS,
326, 326U, 326S, 326T, 326TS, 364, 364S, 364U,
364US, 364T, 364TS, 365, 365S, 365U, 365US,
365T, 365TS, 404, 404S, 404U, 404US, 404T,
404TS, 405, 405S, 405U, 405US, 405T, 405TS, 444,
444S, 444U, 444US, 444T, 444TS, 445, 445S, 445U,
445US, 445T, 445TS, 447TS, 449TS, 504U, 505,
505S
Operating voltage for the motor

Motor Phases

Combo

N/A

1 Phase, 3 Phase

Motor Amps

Number

amps

Current draw for the motor

Motor Horse Power

Number

hp

Motor HP rating

NEMA Designation

Combo

N/A

Motor Power Source

Combo

N/A

Oil Type

Var

N/A

Drip proof, Splash proof, Totally enclosed fan cooled,


Water proof, Explosion proof
Electric, Gasoline, Diesel, Hydraulic, Pneumatic,
Other
Type of oil

Oil Capacity

Number

gallons

Oil Capacity

Uniformat Code

Var

N/A

D2091

Grey highlighted fields indicate a field that must contain information.

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-66
02/29/12

DATA DICTIONARY

12.10.2

PUMP (PMP)

Hierarchical Level:

Component

System Association:

Mechanical

Code:

PMP

Description:

A device for raising, compressing, or transferring fluids. Includes sump pumps, transfer
pumps, etc.

Attribute
Component ID

Data Type
Var

Unit
N/A

Domain / Range of Values


System generated unique id for the entity | barcode

SAP ID

Var

N/A

ID used to reference SAP Asset

FSC ID

Var

N/A

Unique id for the entity | PMP.### for the Facility


based upon the FSC naming convention

Component Description

Text

N/A

A narrative description of the entity

Component Type

Combo

N/A

Centrifugal, Ejector, Sump

System ID
Criticality

Var
Number

N/A
N/A

The system ID that the component is associated to


1, 2, 3, 4, 5

Legacy Names

Var

N/A

Common name or previous name of the entity

Date Entered

Date

N/A

Condition Rating

Number

N/A

System date of when the record was entered into


the database
Condition rating of the component

Inspection Date

Date

N/A

Date of the last inspection for the condition rating

Year Built

Date

N/A

Year that the component was constructed

Design Life

Number

N/A

Design life

Remaining Useful Life

Number

N/A

Remaining useful life estimate

Original Construction Cost

Number

$US

Cost of initial construction or purchase cost

Replacement Cost

Currency

$US

Current replacement value of the component

Model Number

Var

N/A

Manufacturers model number (catalog id)

Serial Number

Var

N/A

Unique identifier for the Component

Pump Manufacturer

Combo

N/A

To be developed on-the-fly

Warranty Period

Date

N/A

Date of warranty expiration

Motor Manufacturer

Combo

N/A

To be developed on-the-fly

Serial Number

Var

N/A

Unique identifier for the Component

Model Number
Application
Mount Style

Var
Combo
Combo

N/A
N/A
N/A

Manufacturers door model number (catalog id)


HVAC, Fire Protection, Sanitary, Domestic Water
in-line, base mount, horizontal mount, vertical
mount, anti-vibration, close coupled, foot mounted,
flange mounted

Grey highlighted fields indicate a field that must contain information.

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-67
02/29/12

DATA DICTIONARY

Attribute
Head Pressure
Gallons Per Minute
Material

Data Type
Number
Number
Combo

Unit
feet
gpm
N/A

RPM
Size

Number
Number

rpm
inches

Domain / Range of Values


Head Pressure
Gallons Per Minute
steel alloy, stainless steel, cast iron, cast bronze,
pvc, reinforced plastic, other
Maximum rpm
Flange size

Motor Manufacturer

Text

N/A

To be developed on-the-fly

Motor Serial Number

Var

N/A

Unique identifier for the Component

Motor Frame Size

Combo

N/A

Motor Voltage

Number

volts

48, 56, 143, 143T, 145, 145T, 182, 182T, 184,


184T, 203, 204, 213, 213T, 215, 215T, 224, 225,
254, 254U, 254T, 256U, 256T, 284, 284U, 284T,
284TS, 286U, 286T, 286TS, 324, 324U, 324S,
324T, 324TS, 326, 326U, 326S, 326T, 326TS, 364,
364S, 364U, 364US, 364T, 364TS, 365, 365S,
365U, 365US, 365T, 365TS, 404, 404S, 404U,
404US, 404T, 404TS, 405, 405S, 405U, 405US,
405T, 405TS, 444, 444S, 444U, 444US, 444T,
444TS, 445, 445S, 445U, 445US, 445T, 445TS,
447TS, 449TS, 504U, 505, 505S
Operating voltage for the motor

Motor Phases

Combo

N/A

1 Phase, 3 Phase

Motor Amps

Number

amps

Current draw for the motor

Motor Horse Power

Number

hp

Motor HP rating

NEMA Designation

Combo

N/A

Motor Power Source

Combo

N/A

Drip proof, Splash proof, Totally enclosed fan


cooled, Water proof, Explosion proof
Electric, Natural gas, Steam, Propane, Other

Mechanical Seal ID

Number

inches

Mechanical Seal ID

Thrust Bearing ID

Number

inches

Thrust Bearing ID

Radial Bearing ID

Number

inches

Radial Bearing ID

Impeller Diameter

Number

inches

Impeller Diameter

Coupling Bores

Number

inches

Coupling Bores

Keyway Size

Number

inches

Keyway Size

Uniformat Code

Var

N/A

D3041 Air distribution, D3043 Steam


distribution, D3044 Hot water distribution, D3045
Chilled water distribution, D3047 Glycol
distribution system

Grey highlighted fields indicate a field that must contain information.

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-68
02/29/12

DATA DICTIONARY

12.11 PLUMBING SYSTEM (PLM)

Hierarchical Level:

System

Facility Association:

Terminal

Code:

PLM

Description:

A system to deliver water in a building.

Attribute
System ID
SAP ID

Data Type
Var
Var

Unit
N/A
N/A

Domain / Range of Values


System generated unique id for the entity | barcode

FSC ID

Var

N/A

System Type

Combo

N/A

Unique id for the entity | PLM.###; RRM.###;


JCL.###; BRM.### for the Facility.
Hot Water, Cold Water

System Description
Criticality
Legacy Names
Date Entered

Text
Number
Var
Date

N/A
N/A
N/A
N/A

Condition Rating

Number

N/A

A narrative description of the entity


1, 2, 3, 4, 5
Common name or previous name of the entity
System date of when the record was entered into
the database
Condition rating of the system

Inspection Date

Date

N/A

Date of the last inspection for the condition rating

Year Built

Date

N/A

Year that the system was constructed

Original Construction Cost

Number

$US

Cost of initial construction or purchase cost

Design Life

Number

N/A

Design life

Remaining Useful Life

Number

N/A

Remaining useful life estimate

Replacement Cost

Currency

$US

Current replacement value of the system

Campus Location

Combo

Address

Var

N/A

Physical address if applicable

Location ID

Var

N/A

Uniformat Code

Var

N/A

GIS Coordinate, Building ID, or other location


reference.
D20

ID used to reference SAP Asset

LAX, VNY, ONT, PMD

Grey highlighted fields indicate a field that must contain information.

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-69
02/29/12

DATA DICTIONARY

12.12 REST ROOM (RRM)

Hierarchical Level:

Location

Facility Association:

Terminal

Code:

Room Number

Description:

A room equipped with plumbing fixtures such as toilets, urinals, wash basins, hand
dryers, change stations, faucets, etc.

Attribute
System ID

Data Type
Var

Unit
N/A

Domain / Range of Values


Unique location id based upon Facility and Space
Naming Convention | bar code applied to location

SAP ID

Var

N/A

ID used to reference SAP Asset

System Description
Criticality
Legacy Names
Date Entered

Text
Number
Var
Date

N/A
N/A
N/A
N/A

Condition Rating

Number

N/A

A narrative description of the entity


1, 2, 3, 4, 5
Common name or previous name of the entity
System date of when the record was entered into
the database
Condition rating of the system

Inspection Date

Date

N/A

Date of the last inspection for the condition rating

Year Built

Date

N/A

Year that the system was constructed

Original Construction Cost

Number

$US

Cost of initial construction or purchase cost

Design Life

Number

N/A

Design life

Remaining Useful Life

Number

N/A

Remaining useful life estimate

Replacement Cost

Currency

$US

Current replacement value of the system

Toilets, qty

Number

each

Number of Toilets

Urinals, qty

Number

each

Number of Urinals

Toilet Compartments, qty

Number

each

Number of Toilet Compartments

Changing Tables, qty

Number

each

Number of Changing Tables

Counter Areas, qty

Number

SF

Counter Area

Hand Dryers, qty

Number

each

Number of Hand Dryers

Light Fixtures, qty

Number

each

Number of Light Fixtures

Wall Areas, qty

Number

SF

Wall Area

Dispensing Fixtures, qty

Number

each

Number of Dispensing Fixtures

Urinal Screens, qty

Number

each

Number of Urinal Screens

Sinks, qty

Number

each

Number of Sinks

Sink Type

Combo

N/A

Hand, Slop, Pedestal, Trough, Vessel

Faucets

Number

each

Faucet Type

Combo

N/A

Ball, Disc, Cartridge, Compression

Grey highlighted fields indicate a field that must contain information.

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-70
02/29/12

DATA DICTIONARY

Attribute
Gender

Data Type
Combo

Unit
N/A

Domain / Range of Values


Female, Male

Campus Location

Combo

Address

Var

N/A

Physical address if applicable

Location ID

Var

N/A

Uniformat Code

Var

N/A

GIS Coordinate, Building ID, or other location


reference.
D2010

LAX, VNY, ONT, PMD

Grey highlighted fields indicate a field that must contain information.

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-71
02/29/12

DATA DICTIONARY

12.13 ROOFING (ROF)


Hierarchical Level:

Location

Facility Association:

Terminal

Code:

ROF

Description:

The exterior surface and its supporting structures on the top of a building.

Attribute
System ID

Data Type
Var

Unit
N/A

SAP ID
System Description
System Type

Var
Text
Combo

N/A
N/A
N/A

Legacy Names
Date Entered

Var
Date

N/A
N/A

Condition Rating

Number

N/A

Domain / Range of Values


Unique id for the entity | ROF.### per the Facility
and Space Naming Convention
ID used to reference SAP Asset
A narrative description of the entity
Mansard, Dome, Hip, Shed, Gambrel, Canopy,
Flat, A Frame/Gable, Arch
Common name or previous name of the entity
System date of when the record was entered into
the database
Condition rating of the system

Inspection Date

Date

N/A

Date of the last inspection for the condition rating

Year Built

Date

N/A

Year that the system was constructed

Design Life

Number

N/A

Design life

Remaining Useful Life

Number

N/A

Remaining useful life estimate

Original Construction Cost

Number

$US

Cost of initial construction or purchase cost

Replacement Cost

Currency

$US

Current replacement value of the system

Warranty Period
Quantity (Area)
Manufacturer
Warranty Number
Material

Date
Number
Text
Var
Combo

N/A
SF
N/A
N/A
N/A

Is Ballasted

Combo

Integer

Date of warranty expiration


Square footage of roof area
To be developed on-the-fly
Manufacturer warranty reference
Built-up, Modified bituminous, Single-ply membrane
unballasted, Inverted membrane, Roll roofing,
Asphalt shingles, Architectural shingles, Wood
shingles, Wood shake roofing, Slate tile, Clay tile,
Metal panel, Standing seam metal, Fiberglass,
Copper, Lead-coated copper, Polyurethane sprayon roofing, Elastomeric roof coating, Other, Singleply membrane ballasted, Glass
Yes, No

Ballast Material

Combo

Var

Pavers, River-rock

Pitch

Number

degree

Roof pitch

Has Lightning Protection

Combo

Integer

False, True

Primary Roof Drain Count

Number

each

Number of primary roof drains

Grey highlighted fields indicate a field that must contain information.

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-72
02/29/12

DATA DICTIONARY

Attribute
Secondary Roof Drain
Count
Gutter Count

Data Type
Number

Unit
each

Domain / Range of Values


Number of secondary roof drains

Number

each

Number of gutters

Downspout Count

Number

each

Number of downspouts

Ventilators, qty

Number

each

Number of ventilators

Skylights, qty

Number

each

Number of skylights

Antenna, qty

Number

each

Number of antennas

Screening, qty

Number

each

Number of screening

Campus Location

Combo

Address

Var

N/A

Physical address if applicable

Location ID

Var

N/A

Uniformat Code

Var

N/A

GIS Coordinate, Building ID, or other location


reference.
D3010

LAX, VNY, ONT, PMD

Grey highlighted fields indicate a field that must contain information.

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-73
02/29/12

DATA DICTIONARY

12.14 BUILDING AUTOMATION SYSTEM (BAS)

Hierarchical Level:

System

Facility Association:

Terminal

Code:

BDA

Description:

A network of integrated computer instruments that automatically control a range of


building operations from lighting to security access to fire safety control.

Attribute

Data Type

Unit

Domain / Range of Values

System ID

Var

N/A

System generated unique id for the entity | barcode

SAP ID
FSC ID

Var
Var

N/A
N/A

System Description
System Type

Text
Combo

N/A
N/A

Legacy Names
Date Entered

Var
Date

N/A
N/A

Condition Rating
Last Inspection Date
Year Built
Design Life

Number
Date
Date
Number

N/A
N/A
N/A
N/A

ID used to reference SAP Asset


Unique id for the entity | BDA.### for the Facility
based upon the FSC naming convention
A narrative description of the entity
Lighting control, recording instrumentation, building
control
Common name or previous name of the entity
System date of when the record was entered into
the database
Condition rating of the system
Date of last inspection for the condition rating
Year that the system was constructed
Design life

Remaining Useful Life

Number

N/A

Remaining useful life estimate

Original Construction
Cost
Replacement Cost
Warranty Period
Campus Location

Number

$US

Cost of initial construction or purchase cost

Currency
Date
Combo

$US
N/A

Current replacement value of the system


Date of warranty expiration
LAX, VNY, ONT, PMD

Address

Var

N/A

Physical address if applicable

Location ID

Var

N/A

Uniformat Code

Var

N/A

GIS Coordinate, Building ID, or other location


reference.
F1052

Grey highlighted fields indicate a field that must contain information.

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-74
02/29/12

DATA DICTIONARY

12.15 BAGGAGE HANDLING SYSTEM (BHS)

Hierarchical Level:

System

Facility Association:

Terminal

Code:

BHS

Description:

A system that transports checked luggage from ticket counters to areas where bags
can be loaded onto aircraft.

Attribute
System ID

Data Type
Var

Unit
N/A

Domain / Range of Values


System generated unique id for the entity | barcode

SAP ID
FSC ID

Var
Var

N/A
N/A

System Description
System Type

Text
Combo

N/A
N/A

Area Served

Combo

N/A

Legacy Names
Date Entered

Var
Date

N/A
N/A

Condition Rating
Last Inspection Date
Year Built
Design Life

Number
Date
Date
Number

N/A
N/A
N/A
N/A

ID used to reference SAP Asset


Unique id for the entity | BHS.### for the Facility
based upon the FSC naming convention
A narrative description of the entity
Inbound, Carousels, Oversize, ticket counter,
Curbside, Mainline, Recirculation line, Scanner
array,
Arrival Level, Departure Level, Baggage Make-up
Area
Common name or previous name of the entity
System date of when the record was entered into
the database
Condition rating of the system
Date of last inspection for the condition rating
Year that the system was constructed
Design life

Remaining Useful Life

Number

N/A

Remaining useful life estimate

Original Construction Cost


Replacement Cost
Warranty Period
Number of Conveyors

Number
Currency
Date
Number

$US
$US
N/A
each

Cost of initial construction or purchase cost


Current replacement value of the system
Date of warranty expiration
Number of Conveyors

Conveyor Length

Number

feet

Overall conveyor Length

Manufacturer

Combo

N/A

Built on-the-fly

Serial Number

Var

N/A

Unique identifier for the Component

Model Number
Campus Location

Var
Combo

N/A

Manufacturers model number (catalog id)


LAX, VNY, ONT, PMD

Address

Var

N/A

Physical address if applicable

Location ID

Var

N/A

Uniformat Code

Var

N/A

GIS Coordinate, Building ID, or other location


reference.
D1097

Grey highlighted fields indicate a field that must contain information.

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-75
02/29/12

DATA DICTIONARY

12.16 PASSENGER BOARDING BRIDGE (PBB)

Hierarchical Level:

System

Facility Association:

Terminal

Code:

PBB

Description:

An extendable bridge for loading passengers onto aircraft. It provides protected access
from the gate to the plane.

Attribute
System ID

Data Type
Var

Unit
N/A

Domain / Range of Values


System generated unique id for the entity | barcode

SAP ID
FSC ID

Var
Var

N/A
N/A

System Description
Legacy Names
Date Entered

Text
Var
Date

N/A
N/A
N/A

Condition Rating
Last Inspection Date
Year Built
Design Life

Number
Date
Date
Number

N/A
N/A
N/A
N/A

ID used to reference SAP Asset


Unique id for the entity | PBB.### for the Facility
based upon LAWA naming convention using the
terminal and gate number. See FSC Naming
convention.
A narrative description of the entity
Common name or previous name of the entity
System date of when the record was entered into
the database
Condition rating of the system
Date of last inspection for the condition rating
Year that the system was constructed
Design life

Remaining Useful Life

Number

N/A

Remaining useful life estimate

Original Construction
Cost
Replacement Cost
Warranty Period
Bridge Length

Number

$US

Cost of initial construction or purchase cost

Currency
Date
Number

$US
N/A
feet

Current replacement value of the system


Date of warranty expiration
Overall conveyor Length

Manufacturer

Combo

N/A

Built on-the-fly

Serial Number

Var

N/A

Unique identifier for the Component

Model Number
Campus Location

Var
Combo

N/A

Manufacturers model number (catalog id)


LAX, VNY, ONT, PMD

Address

Var

N/A

Physical address if applicable

Location ID

Var

N/A

Uniformat Code

Var

N/A

GIS Coordinate, Building ID, or other location


reference.
F1012

Grey highlighted fields indicate a field that must contain information.

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-76
02/29/12

DATA DICTIONARY

12.17 COMMUNICATION (COM)

Hierarchical Level:

System

Facility Group:

Terminal

Code:

COM

Description:

A telephone, radio, television, data transmission, or other system in which informationbearing signals originated at one place are reproduced at a distant point.

Attribute
System ID
SAP ID
FSC ID

Data Type
Var
Var
Var

Unit
N/A
N/A
N/A

System Description
Legacy Names
Date Entered

Text
Var
Date

N/A
N/A
N/A

System Type

Combo

N/A

Criticality

Number

N/A

Domain / Range of Values


System generated unique id for the entity | barcode
ID used to reference SAP Asset
Unique id for the entity | COM.### for the Facility
based upon the FSC naming convention
A narrative description for the entity
Common name or previous name of the entity
System date of when the record was entered into the
database
IT Network, CCTV, Phone, Radio, Security, Fire,
Paging, Clock
1, 2, 3, 4, 5

Condition Rating
Last Inspection Date
Year Built
Design Life

Number
Date
Date
Number

N/A
N/A
N/A
N/A

Condition rating of the system


Date of last inspection for the condition rating
Year that the system was constructed
Design life

Remaining Useful Life

Number

N/A

Remaining useful life estimate

Original Construction
Cost
Replacement Cost
Warranty Period
Campus Location

Number

$US

Cost of initial construction or purchase cost

Currency
Date
Combo

$US
N/A
N/A

Current replacement value of the system


Date of warranty expiration
LAX, VNY, ONT, PMD

Address

Var

N/A

Physical address if applicable

Location ID

Var

N/A

Uniformat Code

Var

N/A

GIS Coordinate, Building ID, or other location


reference.
D5031-Public Address & Music Systems; D5032Intercommunication & Paging System; D5033Telephone Systems; D5034-Call Systems; D5035Television Systems; D5036-Clock and Program
Systems; D5037-Fire Alarm Systems; D5038-Security
and Detection Systems; D5039-Local Area Networks

Grey highlighted fields indicate a field that must contain information.

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-77
02/29/12

DATA DICTIONARY

12.17.1

COMMUNICATION COMPONENTS

Hierarchical Level:

Component

System Association:

Communication

Code:

CMC

Description:

A component of a communication system such as a CCTV camera, network router,


radio base station, etc.

Attribute

Data Type

Unit

Domain / Range of Values

Component ID

Var

N/A

System generated unique id for the entity | barcode

SAP ID

Var

N/A

ID used to reference SAP Asset

FSC ID

Var

N/A

Unique id for the entity | CMC.### for the Facility


based upon the FSC naming convention

Component Description

Text

N/A

A narrative description of the entity

Component Type

Combo

N/A

Camera, Network Hub, Radio base, Clock

System ID
Criticality

Var
Number

N/A
N/A

The system ID that the component is associated to


1, 2, 3, 4, 5

Legacy Names

Var

N/A

Common name or previous name of the entity

Date Entered

Date

N/A

Condition Rating

Number

N/A

System date of when the record was entered into


the database
Condition rating of the component

Inspection Date

Date

N/A

Date of the last inspection for the condition rating

Year Built

Date

N/A

Year that the component was constructed

Design Life

Number

N/A

Design life

Remaining Useful Life

Number

N/A

Remaining useful life estimate

Original Construction Cost

Number

$US

Cost of initial construction or purchase cost

Replacement Cost

Currency

$US

Current replacement value of the component

Manufacturer

Combo

N/A

To be developed on-the-fly

Model Number

Var

N/A

Manufacturers model number (catalog id)

Serial Number

Var

N/A

Unique ID provided by the manufacturer

Uniformat Code

Var

N/A

D5031 Public Address & Music Systems


D5032 Intercommunication & Paging System
D5033 Telephone Systems
D5034 Call Systems
D5035 Television Systems
D5036 Clock and Program Systems
D5037 Fire Alarm Systems
D5038 Security and Detection Systems
D5039 Local Area Networks

Grey highlighted fields indicate a field that must contain information.

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-78
02/29/12

DATA DICTIONARY

13.0 COMMUNICATION (COM)

Hierarchical Level:

Facility

Facility Group:

Utility Infrastructure

Code:

COM

Description:

A telephone, radio, television, data transmission, or other system in which informationbearing signals originated at one place are reproduced at a distant point.

Attribute
System ID
SAP ID
FSC ID

Data Type
Var
Var
Var

Unit
N/A
N/A
N/A

System Description
Legacy Names
Date Entered

Text
Var
Date

N/A
N/A
N/A

System Type

Combo

N/A

Criticality

Number

N/A

Domain / Range of Values


System generated unique id for the entity | barcode
ID used to reference SAP Asset
Unique id for the entity | COM.### for the Facility
based upon the FSC naming convention
A narrative description for the entity
Common name or previous name of the entity
System date of when the record was entered into the
database
IT Network, CCTV, Phone, Radio, Security, Fire,
Paging, Clock
1, 2, 3, 4, 5

Condition Rating
Last Inspection Date
Year Built
Design Life

Number
Date
Date
Number

N/A
N/A
N/A
N/A

Condition rating of the system


Date of last inspection for the condition rating
Year that the system was constructed
Design life

Remaining Useful Life

Number

N/A

Remaining useful life estimate

Original Construction
Cost
Replacement Cost
Warranty Period
Campus Location

Number

$US

Cost of initial construction or purchase cost

Currency
Date
Combo

$US
N/A
N/A

Current replacement value of the system


Date of warranty expiration
LAX, VNY, ONT, PMD

Address

Var

N/A

Physical address if applicable

Location ID

Var

N/A

Uniformat Code

Var

N/A

GIS Coordinate, Building ID, or other location


reference.
G4031 Site Communications Systems
G4032 Site Security & Alarm Systems

Grey highlighted fields indicate a field that must contain information.

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-79
02/29/12

DATA DICTIONARY

13.1.1

COMMUNICATION COMPONENTS

Hierarchical Level:

Component

System Association:

Communication

Code:

CMC

Description:

A component of a communication system such as a CCTV camera, Network router,


radio base station, etc.

Attribute

Data Type

Unit

Domain / Range of Values

Component ID

Var

N/A

System generated unique id for the entity | barcode

SAP ID

Var

N/A

ID used to reference SAP Asset

FSC ID

Var

N/A

Unique id for the entity | CMC.### for the Facility


based upon the FSC naming convention

Component Description

Text

N/A

A narrative description of the entity

Component Type

Combo

N/A

Camera, Network hub, Radio Base, Clock

System ID
Criticality

Var
Number

N/A
N/A

The system ID that the component is associated to


1, 2, 3, 4, 5

Legacy Names

Var

N/A

Common name or previous name of the entity

Date Entered

Date

N/A

Condition Rating

Number

N/A

System date of when the record was entered into


the database
Condition rating of the component

Inspection Date

Date

N/A

Date of the last inspection for the condition rating

Year Built

Date

N/A

Year that the component was constructed

Design Life

Number

N/A

Design life

Remaining Useful Life

Number

N/A

Remaining useful life estimate

Original Construction Cost

Number

$US

Cost of initial construction or purchase cost

Replacement Cost

Currency

$US

Current replacement value of the component

Manufacturer

Combo

N/A

To be developed on-the-fly

Model Number

Var

N/A

Manufacturers model number (catalog id)

Serial Number

Var

N/A

Unique ID provided by the manufacturer

Uniformat Code

Var

N/A

G4031 Site Communications Systems


G4032 Site Security & Alarm Systems

Grey highlighted fields indicate a field that must contain information.

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-80
02/29/12

DATA DICTIONARY

14.0 FUEL (FUL)

Hierarchical Level:

System

Facility Group:

Utility Infrastructure

Code:

FUL

Description:

Fuel distribution systems.

Attribute

Data Type

Unit

Domain / Range of Values

System ID

Var

N/A

System generated unique id for the entity | barcode

SAP ID

Var

N/A

ID used to reference SAP Asset

FSC ID

Var

N/A

Unique id for the entity | FUL.### for the Facility based


upon the FSC naming convention

System type
Legacy Names

Combo
Var

N/A
N/A

Diesel, Gas, Jet A-1, Jet B


Common name or previous name of the entity

Date Entered

Date

N/A

System date of when the record was entered into the


database

Condition Rating

Number

N/A

Condition rating of the facility

Inspection Date

Date

N/A

Date of the last inspection for the condition rating

Year Built

Date

N/A

Year that the facility was constructed

Design Life

Number

N/A

Design life

Remaining Useful Life

Number

N/A

Remaining useful life estimate

Original Construction
Cost

Number

$US

Cost of initial construction or purchase cost

Replacement Cost

Currency

$US

Current replacement value of the facility

Legacy Names

Var

N/A

Common name or previous name of the entity

Location

Var

N/A

GIS Coordinate, Building ID, or other location reference.

Associated System ID

Var

N/A

Uniformat Code

Var

N/A

G3060

Grey highlighted fields indicate a field that must contain information.

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-81
02/29/12

DATA DICTIONARY

14.1.1

FUEL TANKS (FT)

Hierarchical Level:

Component

System Association:

Fuel System

Code:

FLT

Description:

Fuel storage tanks.

Attribute

Data Type

Unit

Domain / Range of Values

Component ID

Var

N/A

System generated unique id for the entity | barcode

SAP ID

Var

N/A

ID used to reference SAP Asset

FSC ID

Var

N/A

Unique id for the entity | FLT.### for the Facility


based upon the FSC naming convention

Component Description

Text

N/A

A narrative description of the entity

Component Type

Combo

N/A

System ID
Criticality

Var
Number

N/A
N/A

The system ID that the component is associated to


1, 2, 3, 4, 5

Legacy Names

Var

N/A

Common name or previous name of the entity

Date Entered

Date

N/A

Condition Rating

Number

N/A

System date of when the record was entered into the


database
Condition rating of the system

Inspection Date

Date

N/A

Date of the last inspection for the condition rating

Year Built

Date

N/A

Year that the system was constructed

Design Life

Number

N/A

Design life

Remaining Useful Life

Number

N/A

Remaining useful life estimate

Original Construction Cost

Number

$US

Cost of initial construction or purchase cost

Replacement Cost

Currency

$US

Current replacement value of the system

Uniformat Code

Var

N/A

G3063

Grey highlighted fields indicate a field that must contain information.

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-82
02/29/12

DATA DICTIONARY

15.0 NATURAL GAS (NTG)

Hierarchical Level:

Facility

Facility Group:

Utility Infrastructure

Code:

NTG

Description:

Natural Gas distribution systems

Attribute

Data Type

Unit

Domain / Range of Values

System ID

Var

N/A

System generated unique id for the entity | barcode

SAP ID

Var

N/A

ID used to reference SAP Asset

FSC ID

Var

N/A

Unique id for the entity | NTG.### for the Facility


based upon the FSC naming convention

System type

Combo

N/A

Date Entered

Date

N/A

System date of when the record was entered into the


database

Condition Rating

Number

N/A

Condition rating of the facility

Inspection Date

Date

N/A

Date of the last inspection for the condition rating

Year Built

Date

N/A

Year that the facility was constructed

Design Life

Number

N/A

Design life

Remaining Useful Life

Number

N/A

Remaining useful life estimate

Original Construction Cost

Number

$US

Cost of initial construction or purchase cost

Replacement Cost

Currency

$US

Current replacement value of the facility

Legacy Names

Var

N/A

Common name or previous name of the entity

Location

Var

N/A

GIS Coordinate, Building ID, or other location


reference.

Associated System ID

Var

N/A

Uniformat Code

Var

N/A

Grey highlighted fields indicate a field that must contain information.

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-83
02/29/12

DATA DICTIONARY

16.0 STORM DRAIN (SDN)

Hierarchical Level:

Facility

Facility Group:

Utility Infrastructure

Code:

SDN

Description:

A drain or drain system designed to drain excess rain and ground water from paved
streets, parking lots, sidewalks, and roofs.

Attribute

Data Type

Unit

Domain / Range of Values

System ID

Var

N/A

System generated unique id for the entity | barcode

SAP ID

Var

N/A

ID used to reference SAP Asset

FSC ID

Var

N/A

Unique id for the entity | SDN.### for the Facility


based upon the FSC naming convention

System type

Combo

N/A

Date Entered

Date

N/A

System date of when the record was entered into


the database

Condition Rating

Number

N/A

Condition rating of the facility

Inspection Date

Date

N/A

Date of the last inspection for the condition rating

Year Built

Date

N/A

Year that the facility was constructed

Design Life

Number

N/A

Design life

Remaining Useful Life

Number

N/A

Remaining useful life estimate

Original Construction Cost

Number

$US

Cost of initial construction or purchase cost

Replacement Cost

Currency

$US

Current replacement value of the facility

Legacy Names

Var

N/A

Common name or previous name of the entity

Location

Var

N/A

GIS Coordinate, Building ID, or other location


reference.

Associated System ID

Var

N/A

Uniformat Code

Var

N/A

Grey highlighted fields indicate a field that must contain information.

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-84
02/29/12

DATA DICTIONARY

17.0 WATER (WTR)

Hierarchical Level:

Facility

Facility Group:

Utility Infrastructure

Code:

WTR

Description:

Water supply is the provision of water via a system of pumps and pipes.

Attribute

Data Type

Unit

Domain / Range of Values

System ID

Var

N/A

System generated unique id for the entity | barcode

SAP ID

Var

N/A

ID used to reference SAP Asset

FSC ID

Var

N/A

Unique id for the entity | WTR.### for the Facility


based upon the FSC naming convention

System type

Combo

N/A

Date Entered

Date

N/A

System date of when the record was entered into


the database

Condition Rating

Number

N/A

Condition rating of the facility

Inspection Date

Date

N/A

Date of the last inspection for the condition rating

Year Built

Date

N/A

Year that the facility was constructed

Design Life

Number

N/A

Design life

Remaining Useful Life

Number

N/A

Remaining useful life estimate

Original Construction Cost

Number

$US

Cost of initial construction or purchase cost

Replacement Cost

Currency

$US

Current replacement value of the facility

Legacy Names

Var

N/A

Common name or previous name of the entity

Location

Var

N/A

GIS Coordinate, Building ID, or other location


reference.

Associated System ID

Var

N/A

Uniformat Code

Var

N/A

Grey highlighted fields indicate a field that must contain information.

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-85
02/29/12

DATA DICTIONARY

18.0 COMPRESSED AIR (CMA)

Hierarchical Level:

Facility

Facility Group:

Utility Infrastructure

Code:

CMA

Description:

Compressed Air distribution system

Attribute

Data Type

Unit

Domain / Range of Values

System ID

Var

N/A

System generated unique id for the entity | barcode

SAP ID

Var

N/A

ID used to reference SAP Asset

FSC ID

Var

N/A

Unique id for the entity | CMA.### for the Facility


based upon the FSC naming convention

System type

Combo

N/A

Date Entered

Date

N/A

System date of when the record was entered into


the database

Condition Rating

Number

N/A

Condition rating of the facility

Inspection Date

Date

N/A

Date of the last inspection for the condition rating

Year Built

Date

N/A

Year that the facility was constructed

Design Life

Number

N/A

Design life

Remaining Useful Life

Number

N/A

Remaining useful life estimate

Original Construction Cost

Number

$US

Cost of initial construction or purchase cost

Replacement Cost

Currency

$US

Current replacement value of the facility

Legacy Names

Var

N/A

Common name or previous name of the entity

Location

Var

N/A

GIS Coordinate, Building ID, or other location


reference.

Associated System ID

Var

N/A

Uniformat Code

Var

N/A

Grey highlighted fields indicate a field that must contain information.

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-86
02/29/12

DATA DICTIONARY

19.0 INDUSTRIAL WASTE (INW)

Hierarchical Level:

Facility

Facility Group:

Utility Infrastructure

Code:

INW

Description:

Treatment of industrial waste and processed. The equipment may include clarification
units, disinfection, sludge or nutrient removal units, discharge piping and trash
compactors.

Attribute

Data Type

Unit

Domain / Range of Values

System ID

Var

N/A

System generated unique id for the entity | barcode

SAP ID

Var

N/A

ID used to reference SAP Asset

FSC ID

Var

N/A

Unique id for the entity | INW.### for the Facility based


upon the FSC naming convention

System type

Combo

N/A

Date Entered

Date

N/A

System date of when the record was entered into the


database

Condition Rating

Number

N/A

Condition rating of the facility

Inspection Date

Date

N/A

Date of the last inspection for the condition rating

Year Built

Date

N/A

Year that the facility was constructed

Design Life

Number

N/A

Design life

Remaining Useful Life

Number

N/A

Remaining useful life estimate

Original Construction Cost

Number

$US

Cost of initial construction or purchase cost

Replacement Cost

Currency

$US

Current replacement value of the facility

Legacy Names

Var

N/A

Common name or previous name of the entity

Location

Var

N/A

GIS Coordinate, Building ID, or other location


reference.

Associated System ID

Var

N/A

Uniformat Code

Var

N/A

Grey highlighted fields indicate a field that must contain information.

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-87
02/29/12

DATA DICTIONARY

19.1.1

TRASH COMPACTOR (TRC)

Hierarchical Level:

Component

Facility Group:

Industrial Waste System

Code:

TRC

Description:

Mechanized compaction of solid waste.

Attribute

Data Type

Unit

Domain / Range of Values

System ID

Var

N/A

System generated unique id for the entity | barcode

SAP ID

Var

N/A

ID used to reference SAP Asset

FSC ID

Var

N/A

Unique id for the entity | INW.### for the Facility based


upon the FSC naming convention

System type

Combo

N/A

Date Entered

Date

N/A

System date of when the record was entered into the


database

Condition Rating

Number

N/A

Condition rating of the facility

Inspection Date

Date

N/A

Date of the last inspection for the condition rating

Year Built

Date

N/A

Year that the facility was constructed

Design Life

Number

N/A

Design life

Remaining Useful Life

Number

N/A

Remaining useful life estimate

Original Construction Cost

Number

$US

Cost of initial construction or purchase cost

Replacement Cost

Currency

$US

Current replacement value of the facility

Legacy Names

Var

N/A

Common name or previous name of the entity

Motor Horsepower

Number

HP

Motor Quantity

Number

EA

Motor Amps

Number

Motor Manufacturer

Var

N/A

Motor Voltage

Number

Location

Var

N/A

Associated System ID

Var

N/A

Uniformat Code

Var

N/A

GIS Coordinate, Building ID, or other location


reference.

G3091

Grey highlighted fields indicate a field that must contain information.

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-88
02/29/12

DATA DICTIONARY

20.0 ELECTRICAL (ELE)

Hierarchical Level:

Facility

Facility Group:

Utility Infrastructure

Code:

ELE

Description:

Electricity distribution is the delivery of electricity to end users. A distribution system's


network carries electricity from the transmission system and delivers it to consumers.
Typically, the network would include medium-voltage (less than 50 kV) power lines,
substations and pole-mounted transformers, low-voltage (less than 1 kV) distribution
wiring and sometimes meters.

Attribute

Data Type

Unit

Domain / Range of Values

System ID

Var

N/A

System generated unique id for the entity | barcode

SAP ID

Var

N/A

ID used to reference SAP Asset

FSC ID

Var

N/A

Unique id for the entity | ELE.### for the Facility


based upon the FSC naming convention

System type

Combo

N/A

Date Entered

Date

N/A

System date of when the record was entered into


the database

Condition Rating

Number

N/A

Condition rating of the facility

Inspection Date

Date

N/A

Date of the last inspection for the condition rating

Year Built

Date

N/A

Year that the facility was constructed

Design Life

Number

N/A

Design life

Remaining Useful Life

Number

N/A

Remaining useful life estimate

Original Construction Cost

Number

$US

Cost of initial construction or purchase cost

Replacement Cost

Currency

$US

Current replacement value of the facility

Legacy Names

Var

N/A

Common name or previous name of the entity

Location

Var

N/A

GIS Coordinate, Building ID, or other location


reference.

Associated System ID

Var

N/A

Uniformat Code

Var

N/A

Grey highlighted fields indicate a field that must contain information.

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-89
02/29/12

DATA DICTIONARY

21.0 HEAT/COOL DISTRIBUTION (HCD)

Hierarchical Level:

Facility

Facility Group:

Utility Infrastructure

Code:

HCD

Description:

Distribution of chilled water, hot water and steam to facilities for heating and cooling of
the facilities.

Attribute

Data Type

Unit

Domain / Range of Values

System ID

Var

N/A

System generated unique id for the entity | barcode

SAP ID

Var

N/A

ID used to reference SAP Asset

FSC ID

Var

N/A

Unique id for the entity | HCD.### for the Facility


based upon the FSC naming convention

System type

Combo

N/A

Date Entered

Date

N/A

System date of when the record was entered into


the database

Condition Rating

Number

N/A

Condition rating of the facility

Inspection Date

Date

N/A

Date of the last inspection for the condition rating

Year Built

Date

N/A

Year that the facility was constructed

Design Life

Number

N/A

Design life

Remaining Useful Life

Number

N/A

Remaining useful life estimate

Original Construction Cost

Number

$US

Cost of initial construction or purchase cost

Replacement Cost

Currency

$US

Current replacement value of the facility

Legacy Names

Var

N/A

Common name or previous name of the entity

Location

Var

N/A

GIS Coordinate, Building ID, or other location


reference.

Associated System ID

Var

N/A

Uniformat Code

Var

N/A

Grey highlighted fields indicate a field that must contain information.

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-90
02/29/12

DATA DICTIONARY

22.0 REGISTERED COMPONENTS NO ATTRIBUTES


The following components are registered but do not have associated attributes. In many cases these
components require regular inspections and require verification and documentation.

Component Description

FSC Code

Requirement

Fire Extinguisher

FXH

Perform monthly inspections

Fire Hose Cabinet

FHC

Replace fire hoses after 5 years

Medical Devices

MED

Perform regular inspections

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-91
02/29/12

DATA DICTIONARY

APPENDIX 3C: ASTM UNIFORMAT II CLASSIFICATION FOR BUILDING


ELEMENTS (E1557-97)
Level 1
Major Group Elements

Level 2
Group Elements

Level 3
Individual Elements
A1010 Standard Foundations

A10 Foundations

A1020 Special Foundations


A1030 Slab on Grade

A SUBSTRUCTURE

A2010 Basement Excavation


A20 Basement Construction
A2020 Basement Walls
B1010 Floor Construction
B10 Super Structure
B1020 Roof Construction
B2010 Exterior Walls
B SHELL

B20 Exterior Enclosure

B2020 Exterior Windows


B2030 Exterior Doors
B3010 Roof Coverings

B30 Roofing
B3020 Roof Openings
C1010 Partitions
C10 Interior Construction

C1020 Interior Doors


C1030 Fittings

C INTERIORS

C2010 Stair Construction


C20 Stairs
C2020 Stair Finishes
C3010 Wall Finishes
C30 Interior Finishes

C3020 Floor Finishes


C3030 Ceiling Finishes
D1010 Elevators & Lifts

D10 Conveying

D1020 Escalators & Moving Walks


D1090 Other Conveying Systems
D2010 Plumbing Fixtures
D2020 Domestic Water Distribution

D20 Plumbing

D2030 Sanitary Waste


D2040 Rain Water Drainage

D SERVICES

D2090 Other Plumbing Systems


D3010 Energy Supply
D3020 Heat Generating Systems
D3030 Cooling Generating Systems
D30 HVAC

D3040 Distribution Systems


D3050 Terminal & Package Units
D3060 Controls & Instrumentation
D3070 Systems Testing & Balancing
2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-92
02/29/12

DATA DICTIONARY

Level 1
Major Group Elements

Level 2
Group Elements

Level 3
Individual Elements
D3090 Other HVAC Systems & Equipment
D4010 Sprinklers
D4020 Standpipes

D40 Fire Protection


D4030 Fire Protection Specialties
D4090 Other Fire Protection Systems
D5010 Electrical Service & Distribution
D5020 Lighting and Branch Wiring
D50 Electrical
D5030 Communications & Security
D5090 Other Electrical Systems
E1010 Commercial Equipment
E1020 Institutional Equipment
E10 Equipment
E1030 Vehicular Equipment
E EQUIPMENT & FURNISHINGS

E1090 Other Equipment


E2010 Fixed Furnishings
E20 Furnishings
E2020 Movable Furnishings
F1010 Special Structures
F1020 Integrated Construction
F10 Special Construction

F1030 Special Construction Systems


F1040 Special Facilities

F SPECIAL CONSTRUCTION &


DEMOLITION

F1050 Special Controls and


Instrumentation
F2010 Building Elements Demolition
F20 Selective Building Demolition
F2020 Hazardous Components Abatement

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-93
02/29/12

DATA DICTIONARY

Level 1
Major Group Elements

Level 2
Group Elements

Level 3
Individual Elements
G1010 Site Clearing
G1020 Site Demolition and Relocations

G10 Site Preparation


G1030 Site Earthwork
G1040 Hazardous Waste Remediation
G2010 Roadways
G2020 Parking Lots
G20 Site Improvements

G2030 Pedestrian Paving


G2040 Site Development
G2050 Landscaping
G3010 Water Supply

G BUILDING SITEWORK
G3020 Sanitary Sewer
G3030 Storm Sewer
G30 Site Mechanical Utilities

G3040 Heating Distribution


G3050 Cooling Distribution
G3060 Fuel Distribution
G3090 Other Site Mechanical Utilities
G4010 Electrical Distribution
G4020 Site Lighting

G40 Site Electrical Utilities


G4030 Site Communications & Security
G4090 Other Site Electrical Utilities
G9010 Service and Pedestrian Tunnels
G90 Other Site Construction
G9090 Other Site Systems & Equipment

The classification was designed to meet the following additional requirements:

Applies to any building type, although it is designed for commercial buildings.


Allows specific details required for describing specialized buildings.
Separates the classification of building elements from the classification of building related site-work.
Relates to other elemental classifications such as the original UNIFORMAT and those of the Canadian
Institute of Quantity Surveyors (CIQS) and the Royal Institute of Chartered Surveyors (RICS-UK).

UNIFORMAT II is not intended to classify elements of major civil works. Buildings, however, are usually
accompanied by roads, utilities, parking areas and other non-building features. The UNIFORMAT II
classification of building-related site-work is provided for exclusive use in support of construction of buildings so
users do not have to resort to multiple elemental classifications for what is primarily a buildings project.

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-94
02/29/12

DATA DICTIONARY

Level 4 for the UNIFORMAT II Classification of Building- Related Sitework


Level 3 Elements

Level 4 Sub-Elements

A1010 Standard
Foundations

A1011 Wall Foundations

A2022 Moisture Protection

A1012 Column Foundations &


Pile Caps

A2023 Basement Wall


Insulation

A1013 Perimeter Drainage &


Insulation

A2024 Interior Skin

A1020 Special
Foundations

A1021 Pile Foundations

Level 3 Elements

B1010 Floor
Construction

A1022 Grade Beams

Level 4 Sub-Elements

B1011 Suspended Basement


Floors Construction
B1012 Upper Floors
Construction

A1023 Caissons
B1013 Balcony Floors
Construction

A1024 Underprinting

B1014 Ramps

A1025 Dewatering
A1026 Raft Foundations

B1015 Exterior Stairs and Fire


Escapes

A1027 Pressure Injected


Grouting

B1016 Floor Raceway Systems


B1019 Other Floor Construction

A1029 Other Special Conditions


A1030 Slab on
Grade

A1031 Standard Slab on Grade

B1022 Pitched Roof


Construction

A1033 Inclined Slab on Grade

B1023 Canopies

A1034 Trenches, Pits & Bases

B1029 Other Roof Systems

A2011 Excavation for


Basements
A2012 Structure Back Fill &
Compaction

A2020 Basement
Walls

B1021 Flat Roof Construction

A1032 Structural Slab on Grade

A1035 Under-Slab Drainage &


Insulation
A2010 Basement
Excavation

B1020 Roof
Construction

B2010 Exterior
Walls

B2011 Exterior Wall


Construction
B2012 Parapets
B2013 Exterior Louvers,
Screens, and Fencing

A2013 Shoring

B2014 Exterior Sun Control


Devices

A2021 Basement Wall


Construction

B2015 Balcony Walls &


Handrails

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

Page:
Date:

12B.1-95
02/29/12

DATA DICTIONARY

Level 3 Elements

B2020 Exterior
Windows

Level 4 Sub-Elements

Level 3 Elements

Level 4 Sub-Elements

B2016 Exterior Soffits

C1014 Site Built Toilet Partitions

B2021 Windows

C1015 Site Built Compartments


Cubicles
C1016 Interior Balustrades and
Screens

B2022 Curtain Walls


C1017 Interior Windows &
Storefronts

B2023 Storefronts
B2030 Exterior
Doors

B2031 Glazed Doors &


Entrances

C1020 Interior
Doors

C1021 Interior Doors


C1022 Interior Door Frames

B2032 Solid Exterior Doors


C1023 Interior Door Hardware
B2033 Revolving Doors
C1024 Interior Door Wall
Opening Elements

B2034 Overhead Doors

C1025 Interior Door Sidelights &


Transoms

B2039 Other Doors & Entrances


B3010 Roof
Coverings

B3011 Roof Finishes

C1026 Interior Hatches &


Access Doors

B3012 Traffic Toppings &


Paving Membranes

C1027 Door Painting &


Decoration

B3013 Roof Insulation & Fill


C1030 Fittings
B3014 Flashings & Trim

C1032 Fabricated
Compartments & Cubicles

B3015 Roof Eaves and Soffits


B3016 Gutters and Downspouts
B3020 Roof
Openings

C1010 Partitions

C1031 Fabricated Toilet


Partitions

C1033 Storage Shelving and


Lockers

B3021 Glazed Roof Openings


B3022 Roof Hatches

C1034 Ornamental Metals and


Handrails

B3023 Gravity Roof Ventilators

C1035 Identifying Devices

C1011 Fixed Partitions

C1036 Closet Specialties

C1012 Demountable Partitions

C1037 General Fittings & Misc.


Metals

C1013 Retractable Partitions


C2010 Stair

C2011 Regular Stairs

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-96
02/29/12

DATA DICTIONARY

Level 3 Elements
Construction

Level 4 Sub-Elements

Level 3 Elements

C2012 Curved Stairs


C2013 Spiral Stairs

D1013 Lifts
D1020 Escalators &
Moving Walks

C2014 Stair Handrails and


Balustrades
C2020 Stair
Finishes

C2021 Stair, Tread, and


Landing Finishes

Level 4 Sub-Elements

D1021 Escalators
D1022 Moving Walks

D1090 Other
Conveying Systems

D1091 Dumbwaiters
D1092 Pneumatic Tube
Systems

C2022 Stair Soffit Finishes


D1093 Hoists & Cranes
C2023 Stair Handrail &
Balustrade Finishes
C3010 Wall
Finishes

D1094 Conveyors

C3011 Wall Finishes to Inside


Exterior Walls

D1095 Chutes
D1096 Turntables

C3012 Wall Finishes to Interior


Walls

C3020 Floor
Finishes

C3013 Column Finishes

D1097 Baggage Handling &


Loading Systems

C3021 Floor Toppings

D1098 Transportation Systems

C3022 Traffic Membranes

D2010 Plumbing
Fixtures

D2011 Water Closets

C3023 Hardeners and Sealers

D2012 Urinals

C3024 Flooring

D2013 Lavatories

C3025 Carpeting

D2014 Sinks

C3026 Bases, Curbs and Trim

D2015 Bathtubs

C3027 Access Pedestal


Flooring

D2016 Wash Fountains


D2017 Showers

C3030 Ceiling
Finishes

C3031 Ceiling Finishes


D2018 Drinking Fountains and
Coolers

C3032 Suspended Ceilings

D2019 Bidets and Other


Plumbing Fixtures

C3033 Other Ceilings


D1010 Elevators &
Lifts

D1011 Passenger Elevators


D1012 Freight Elevators

D2020 Domestic
Water Distribution

D2021 Cold Water Service


D2022 Hot Water Service

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-97
02/29/12

DATA DICTIONARY

Level 3 Elements

Level 4 Sub-Elements

Level 3 Elements

D2023 Domestic Water Supply


Equipment

Level 4 Sub-Elements
D3016 Solar Energy System
D3017 Wind Energy System

D2030 Sanitary
Waste

D2031 Waste Piping


D2032 Vent Piping

D3021 Boilers

D3020 Heat
Generating
Systems

D3022 Boiler Room Piping &


Specialties

D2033 Floor Drains

D2040 Rain Water


Drainage

D2034 Sanitary Waste


Equipment

D3023 Auxiliary Equipment

D2035 Pipe Insulation

D3024 Insulation

D2041 Pipe & Fittings

D3030 Cooling
Generating
Systems

D3031 Chilled Water Systems

D3040 Distribution
Systems

D3041 Air Distribution Systems

D2042 Roof Drains


D2043 Rainwater Drainage
Equipment

D3042 Exhaust Ventilation


Systems

D2044 Pipe Insulation


D2090 Other
Plumbing Systems

D3032 Direct Expansion


Systems

D2091 Gas Distribution

D3043 Steam Distribution


Systems

D2092 Acid Waste Systems


D3044 Hot Water Distribution
D2093 Interceptors
D3045 Chilled Water
Distribution

D2094 Pool Piping and


Equipment

D3046 Change-over Distribution


System

D2095 Decorative Fountain


Piping Devices

D3047 Glycol Distribution


Systems

D2099 Other Piping Systems


D3010 Energy
Supply

D3011 Oil Supply System

D3050 Terminal &


Package Units

D3051 Terminal Self-Contained


Units

D3012 Gas Supply System


D3052 Package Units
D3013 Coal Supply System
D3014 Steam Supply System
D3015 Hot Water Supply
System

D3060 Controls &


Instrumentation

D3061 Heating Generating


Systems
D3062 Cooling Generating
Systems
D3063 Heating/Cooling Air

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-98
02/29/12

DATA DICTIONARY

Level 3 Elements

Level 4 Sub-Elements

Level 3 Elements

Handling Units

Equipment

D3064 Exhaust & Ventilating


Systems

D4013 Dry Sprinkler System


D4020 Standpipes

D3065 Hoods and Exhaust


Systems

D4023 Standpipe Equipment

D3067 Energy Monitoring &


Control
D3068 Building Automation
Systems

D4024 Fire Hose Equipment


D4030 Fire
Protection
Specialties

D4031 Fire Extinguishers

D4090 Other Fire


Protection Systems

D4091 Carbon Dioxide Systems

D4032 Fire Extinguisher


Cabinets

D3069 Other Controls &


Instrumentation

D3090 Other HVAC


Systems &
Equipment

D3071 Piping System Testing &


Balancing

D4021 Standpipe Water Supply


D4022 Pumping Equipment

D3066 Terminal Devices

D3070 Systems
Testing &
Balancing

Level 4 Sub-Elements

D4092 Foam Generating


Equipment

D3072 Air Systems Testing &


Balancing

D4093 Clean Agent Systems

D3073 HVAC Commissioning

D4094 Dry Chemical System

D3079 Other Systems Testing


and Balancing

D4095 Hood & Duct Fire


Protection

D3091 Special Cooling Systems


& Devices

D5010 Electrical
Service &
Distribution

D3092 Special Humidity Control

D5011 High Tension Service &


Dist.
D5012 Low Tension Service &
Dist.

D3093 Dust & Fume Collectors


D3094 Air Curtains

D5020 Lighting &


Branch Wiring

D5021 Branch Wiring Devices


D5022 Lighting Equipment

D3095 Air Purifiers


D3096 Paint Spray Booth
Ventilation
D3097 General Construction
Items (HVAC)

D5030
Communications &
Security

D5031 Public Address & Music


Systems
D5032 Intercommunication &
Paging System
D5033 Telephone Systems

D4010 Sprinklers

D4011 Sprinkler Water Supply


D5034 Call Systems
D4012 Sprinkler Pumping
2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-99
02/29/12

DATA DICTIONARY

Level 3 Elements

Level 4 Sub-Elements

Level 3 Elements

Level 4 Sub-Elements
Equipment

D5035 Television Systems

E1024 Instrumental Equipment

D5036 Clock and Program


Systems

E1025 Audio-visual Equipment


D5037 Fire Alarm Systems
E1026 Detention Equipment

D5090 Other
Electrical System

D5038 Security and Detection


Systems

E1027 Laboratory Equipment

D5039 Local Area Networks

E1028 Medical Equipment

D5091 Grounding Systems

E1029 Other Institutional


Equipment

D5092 Emergency Light &


Power Systems

E1030 Vehicular
Equipment

E1031 Vehicular Service


Equipment

D5093 Floor Raceway Systems


E1032 Parking Control
Equipment

D5094 Other Special Systems &


Devices

E1033 Loading Dock Equipment


D5095 General Construction
Items (Elect.)
E1010 Commercial
Equipment

E1011 Security & Vault


Equipment

E1090 Other
Equipment

E1091 Maintenance Equipment

E1012 Teller and Service


Equipment

E1092 Solid Waste Handling


Equipment

E1013 Registration Equipment

E1093 Food Service Equipment

E1014 Checkroom Equipment

E1094 Residential Equipment

E1015 Mercantile Equipment

E1095 Unit Kitchens

E1016 Laundry & Dry Cleaning


Equipment

E1097 Window Washing


Equipment

E1017 Vending Equipment

E1099 Other Equipment

E1018 Office Equipment


E1020 Institutional
Equipment

E1039 Other Vehicular


Equipment

E2010 Fixed
Furnishings

E2011 Fixed Artwork

E1021 Ecclesiastical Equipment

E2012 Fixed Casework

E1022 Library Equipment

E2013 Blinds and Other


Window Treatment

E1023 Theater & Stage


2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

Page:
Date:

12B.1-100
02/29/12

DATA DICTIONARY

Level 3 Elements

Level 4 Sub-Elements

Level 3 Elements

E2014 Fixed Floor Grilles and


Mats

F1044 Kennels & Animal


Shelters

E2015 Fixed Multiple Seating

F1045 Liquid & Gas Storage


Tanks

E2016 Fixed Interior


Landscaping
E2020 Movable
Furnishings

E2021 Movable Artwork


E2022 Furniture & Accessories

F1049 Other Special Facilities


F1050 Special
Controls &
Instrumentation

F1059 Other Special Controls &


Instrumentation

E2024 Movable Interior


Landscaping
F1011 Air Supported Structures

F2010 Building
Elements
Demolition

F1012 Pre-engineered
Structures
F1013 Other Special Structures
F1020 Integrated
Construction

F1021 Integrated Assemblies

F1030 Special
Construction
Systems

F2020 Hazardous
Components
Abatement

G1010 Site
Clearing

G1011 Clearing & Grubbing


G1012 Tree Removal &
Thinning

G1020 Site
Demolition &
Relocation

F1033 Special Security Systems

F1040 Special
Facilities

F2021 Removal of Hazardous


Components
F2022 Encapsulation of
Hazardous Components

F1031 Sound, Vibration &


Seismic Const.
F1032 Radiation Protection

F2011 Building Interior


Demolition
F2012 Building Exterior
Demolition

F1022 Special Purpose Rooms


F1023 Other Integrated
Construction

F1051 Recording
Instrumentation
F1052 Building Automation
System

E2023 Movable Rugs and Mats

F1010 Special
Structures

Level 4 Sub-Elements

G1021 Building Demolition


G1022 Demolition of Site
Components

F1034 Vaults

G1023 Relocation of Building &


Utilities

F1039 Other Special


Construction Systems

G1024 Utilities Relocation

F1041 Aquatic Facilities

G1030 Site
Earthwork

G1031 Site Grading Excavation

F1042 Ice Rinks

G1032 Borrow Fill

F1043 Site Constructed


Incinerators

G1033 Soil Stabilization &


Treatment
2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-101
02/29/12

DATA DICTIONARY

Level 3 Elements

Level 4 Sub-Elements

Level 3 Elements

Level 4 Sub-Elements

G1034 Site Dewatering

G2040 Site
Development

G2041 Fences & Gates

G1035 Site Shoring

G2042 Retaining Walls

G1036 Embankments

G2043 Terrace & Perimeter


Walls

G1037 Erosion Control


G2044 Signage
G1040 Hazardous
Waste Remediation

G2010 Roadways

G1041 Removal of
Contaminated Soil

G2045 Site Furnishings

G1042 Soil Restoration &


Treatment

G2046 Fountains, Pools, &


Watercourses

G2011 Bases and Sub-Bases

G2047 Playing Fields

G2012 Paving & Surfacing


Structures

G2048 Flagpoles
G2049 Miscellaneous

G2013 Curbs Gutters & Drains

G2050
Landscaping

G2051 Fine Grading & Soil


Preparation

G2014 Guardrails and Barriers


G2052 Erosion Control
Measures

G2015 Painted Lines

G2053 Top Soil and Planting


Beds

G2016 Markings & Signage


G2017 Vehicular Bridges

G2054 Seeding and Sodding


G2020 Parking Lots

G2021 Bases and Sub-Bases


G2055 Planting
G2022 Paving & Surfacing
G2056 Planters
G2023 Curbs, Rails & Barriers
G2057 Irrigation Systems
G2024 Parking Booths &
Equipment

G2059 Other Landscape


Features

G2025 Markings & Signage


G2030 Pedestrian
Paving

G2031 Paving & Surfacing

G3010 Water
Supply

G3011 Potable Water


Distribution and Storage

G2032 Edging

G3012 Non Potable Water


Distrib. and Storage

G2033 Exterior Steps

G3013 Well Systems

G2034 Pedestrian Bridges

G3014 Fire Protection


2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

12B.1-102
02/29/12

DATA DICTIONARY

Level 3 Elements

G3020 Sanitary
Sewer

Level 4 Sub-Elements

Level 3 Elements

Level 4 Sub-Elements

Distribution and Storage

Cooling/Heating

G3015 Pumping Stations

G3053 Pumping Stations

G3016 Package Water


Treatment Plants

G3054 Cooling Towers on Site

G3021 Piping

G3060 Fuel
Distribution

G3061 Fuel Piping


G3062 Fuel Equipment

G3022 Manholes & Cleanouts


G3063 Fuel Storage Tanks
G3023 Septic Disposal Systems
G3064 Fuel Dispensing Stations
G3024 Lift Stations
G3025 Packaged Water Waste
Treatment Plants

G3090 Other Site


Mechanical Utilities

G3092 POL (Petroleum Oil &


Lubricants) Distribution Systems

G3026 Septic Tanks

G3027 Drain Fields


G3030 Storm
Sewer

G4010 Electrical
Distribution

G4013 Underground Power


Distribution

G3032 Manholes
G4020 Site Lighting

G3035 Retention Ponds

G4023 Wiring Conduits &


Ductbanks

G3036 Ditches & Culverts

G4024 Site Lighting Controls

G3041 Steam Supply


G3042 Condensate Return

G4030 Site
Communication &
Security

G3044 Pumping Stations

G4090 Other Site


Electrical Utilities

G4091 Cathodic Protection


G4092 Site Emergency Power
Generation

G3051 Chilled Water Piping


G3052 Wells for

G4031 Site Communications


Systems
G4032 Site Security & Alarm
Systems

G3043 Hot Water Supply


System

G3050 Cooling
Distribution

G4021 Fixtures & Transformers


G4022 Poles

G3034 Lift Stations

G3040 Heating
Distribution

G4011 Substations
G4012 Overhead Power
Distribution

G3031 Piping

G3033 Headwalls & Catch


Basins

G3091 Industrial Waste


Systems

G9010 Service &

G9011 Service Tunnels

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

Page:
Date:

12B.1-103
02/29/12

DATA DICTIONARY

Level 3 Elements
Pedestrian Tunnels

G9090 Other Site


Systems

Level 4 Sub-Elements
G9012 Trench BoxesG9013
Pedestrian Tunnels
G9091 Snow Melting Systems

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

Page:

12B.2-1

ASTM UNIFORMAT II CLASSIFICATION


FOR BUILDING ELEMENTS (E1557-97)

Date:

01/31/12

ASTM UNIFORMAT II CLASSIFICATION FOR BUILDING ELEMENTS


(E1557-97)
Level 1
Major Group Elements

Level 2
Group Elements

Level 3
Individual Elements
A1010 Standard Foundations

A10 Foundations

A1020 Special Foundations


A1030 Slab on Grade

A SUBSTRUCTURE

A2010 Basement Excavation


A20 Basement Construction
A2020 Basement Walls
B1010 Floor Construction
B10 Super Structure
B1020 Roof Construction
B2010 Exterior Walls
B SHELL

B20 Exterior Enclosure

B2020 Exterior Windows


B2030 Exterior Doors
B3010 Roof Coverings

B30 Roofing
B3020 Roof Openings
C1010 Partitions
C10 Interior Construction

C1020 Interior Doors


C1030 Fittings

C INTERIORS

C2010 Stair Construction


C20 Stairs
C2020 Stair Finishes
C3010 Wall Finishes
C30 Interior Finishes

C3020 Floor Finishes


C3030 Ceiling Finishes
D1010 Elevators & Lifts

D10 Conveying

D1020 Escalators & Moving Walks


D1090 Other Conveying Systems
D2010 Plumbing Fixtures

D SERVICES

D2020 Domestic Water Distribution


D2030 Sanitary Waste
D20 Plumbing
D2040 Rain Water Drainage
D2090 Other Plumbing Systems

2012 City of Los Angeles. All rights reserved.

Level 1
Major Group Elements

Facilities Management Handbook

Page:

12B.2-2

ASTM UNIFORMAT II CLASSIFICATION


FOR BUILDING ELEMENTS (E1557-97)

Date:

01/31/12

Level 2
Group Elements

Level 3
Individual Elements
D3010 Energy Supply
D3020 Heat Generating Systems
D3030 Cooling Generating Systems
D3040 Distribution Systems

D30 HVAC
D3050 Terminal & Package Units
D3060 Controls & Instrumentation
D3070 Systems Testing & Balancing
D3090 Other HVAC Systems & Equipment
D4010 Sprinklers
D4020 Standpipes
D40 Fire Protection
D4030 Fire Protection Specialties
D4090 Other Fire Protection Systems
D5010 Electrical Service & Distribution
D5020 Lighting and Branch Wiring
D50 Electrical
D5030 Communications & Security
D5090 Other Electrical Systems
E1010 Commercial Equipment
E1020 Institutional Equipment
E10 Equipment
E1030 Vehicular Equipment
E EQUIPMENT & FURNISHINGS

E1090 Other Equipment


E2010 Fixed Furnishings
E20 Furnishings
E2020 Movable Furnishings
F1010 Special Structures
F1020 Integrated Construction
F10 Special Construction

F1030 Special Construction Systems


F1040 Special Facilities

F SPECIAL CONSTRUCTION &


DEMOLITION

F1050 Special Controls and


Instrumentation
F2010 Building Elements Demolition
F20 Selective Building Demolition
F2020 Hazardous Components Abatement

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

Page:

12B.2-3

ASTM UNIFORMAT II CLASSIFICATION


FOR BUILDING ELEMENTS (E1557-97)

Date:

01/31/12

Level 1

Level 2

Level 3

Major Group Elements

Group Elements

Individual Elements
G1010 Site Clearing
G1020 Site Demolition and Relocations

G10 Site Preparation


G1030 Site Earthwork
G1040 Hazardous Waste Remediation
G2010 Roadways
G2020 Parking Lots
G20 Site Improvements

G2030 Pedestrian Paving


G2040 Site Development
G2050 Landscaping
G3010 Water Supply

G BUILDING SITEWORK

G3020 Sanitary Sewer


G3030 Storm Sewer
G30 Site Mechanical Utilities

G3040 Heating Distribution


G3050 Cooling Distribution
G3060 Fuel Distribution
G3090 Other Site Mechanical Utilities
G4010 Electrical Distribution
G4020 Site Lighting

G40 Site Electrical Utilities


G4030 Site Communications & Security
G4090 Other Site Electrical Utilities
G9010 Service and Pedestrian Tunnels
G90 Other Site Construction
G9090 Other Site Systems & Equipment

The classification was designed to meet the following additional requirements:

Applies to any building type, although it is designed for commercial buildings.


Allows specific details required for describing specialized buildings.
Separates the classification of building elements from the classification of building related sitework.
Relates to other elemental classifications such as the original UNIFORMAT and those of the
Canadian Institute of Quantity Surveyors (CIQS) and the Royal Institute of Chartered Surveyors
(RICS-UK).

UNIFORMAT II is not intended to classify elements of major civil works. Buildings, however, are usually
accompanied by roads, utilities, parking areas and other non-building features. The UNIFORMAT II
classification of building-related site-work is provided for exclusive use in support of construction of
buildings so users do not have to resort to multiple elemental classifications for what is primarily a
buildings project.

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

Page:

12B.2-4

ASTM UNIFORMAT II CLASSIFICATION


FOR BUILDING ELEMENTS (E1557-97)

Date:

01/31/12

Level 4 for the UNIFORMAT II Classification of Building- Related Sitework

Level 3 Elements

Level 4 Sub Elements

Level 3 Elements

Level 4 Sub Elements

A1010 Standard
Foundations

A1011 Wall Foundations

A2020 Basement
Walls

A2021 Basement Wall


Construction

A1020 Special
Foundations

A1012 Column Foundations &


Pile Caps

A2022 Moisture Protection

A1013 Perimeter Drainage &


Insulation

A2023 Basement Wall


Insulation

A1021 Pile Foundations

A2024 Interior Skin

A1022 Grade Beams

B1010 Floor
Construction

B1011 Suspended Basement


Floors Construction

A1023 Caissons
B1012 Upper Floors
Construction

A1024 Underprinting

A1030 Slab on
Grade

A1025 Dewatering

B1013 Balcony Floors


Construction

A1026 Raft Foundations

B1014 Ramps

A1027 Pressure Injected


Grouting

B1015 Exterior Stairs and Fire


Escapes

A1029 Other Special Conditions

B1016 Floor Raceway Systems

A1031 Standard Slab on Grade

B1019 Other Floor Construction

A1032 Structural Slab on Grade

B1020 Roof
Construction

B1021 Flat Roof Construction

A1033 Inclined Slab on Grade

B1022 Pitched Roof


Construction

A1034 Trenches, Pits & Bases


B1023 Canopies
A1035 Under-Slab Drainage &
Insulation
A2010 Basement
Excavation

A2011 Excavation for


Basements

B1029 Other Roof Systems


B2010 Exterior
Walls

B2011 Exterior Wall


Construction

A2012 Structure Back Fill &


Compaction

B2012 Parapets

A2013 Shoring

B2013 Exterior Louvers,


Screens, and Fencing

2012 City of Los Angeles. All rights reserved.

Level 3 Elements

Facilities Management Handbook

Page:

12B.2-5

ASTM UNIFORMAT II CLASSIFICATION


FOR BUILDING ELEMENTS (E1557-97)

Date:

01/31/12

Level 4 Sub Elements

Level 3 Elements

Level 4 Sub Elements

B2014 Exterior Sun Control


Devices

C1010 Partitions

C1011 Fixed Partitions


C1012 Demountable Partitions

B2015 Balcony Walls &


Handrails

C1013 Retractable Partitions

B2016 Exterior Soffits


B2020 Exterior
Windows

B2030 Exterior
Doors

C1014 Site Built Toilet Partitions

B2021 Windows

C1015 Site Built Compartments


Cubicles

B2022 Curtain Walls

C1016 Interior Balustrades and


Screens

B2023 Storefronts

C1017 Interior Windows &


Storefronts

B2031 Glazed Doors &


Entrances

C1020 Interior
Doors

C1021 Interior Doors


C1022 Interior Door Frames

B2032 Solid Exterior Doors


C1023 Interior Door Hardware
B2033 Revolving Doors
C1024 Interior Door Wall
Opening Elements

B2034 Overhead Doors

C1025 Interior Door Sidelights &


Transoms

B2039 Other Doors & Entrances


B3010 Roof
Coverings

B3011 Roof Finishes


C1026 Interior Hatches &
Access Doors

B3012 Traffic Toppings &


Paving Membranes

C1027 Door Painting &


Decoration

B3013 Roof Insulation & Fill


B3014 Flashings & Trim
B3015 Roof Eaves and Soffits

C1030 Fittings

C1031 Fabricated Toilet


Partitions
C1032 Fabricated
Compartments & Cubicles

B3016 Gutters and Downspouts


B3020 Roof
Openings

B3021 Glazed Roof Openings


B3022 Roof Hatches
B3023 Gravity Roof Ventilators

C1033 Storage Shelving and


Lockers
C1034 Ornamental Metals and
Handrails
C1035 Identifying Devices

2012 City of Los Angeles. All rights reserved.

Level 3 Elements

Facilities Management Handbook

Page:

12B.2-6

ASTM UNIFORMAT II CLASSIFICATION


FOR BUILDING ELEMENTS (E1557-97)

Date:

01/31/12

Level 4 Sub Elements

Level 3 Elements

C1036 Closet Specialties


C1037 General Fittings & Misc.
Metals

Level 4 Sub Elements


C3033 Other Ceilings

D1010 Elevators &


Lifts

D1011 Passenger Elevators


D1012 Freight Elevators

C2010 Stair
Construction

C2011 Regular Stairs


D1013 Lifts
C2012 Curved Stairs
C2013 Spiral Stairs

D1020 Escalators &


Moving Walks

D1021 Escalators
D1022 Moving Walks

C2014 Stair Handrails and


Balustrades
C2020 Stair
Finishes

D1090 Other
Conveying Systems

C2021 Stair, Tread, and


Landing Finishes

D1092 Pneumatic Tube


Systems

C2022 Stair Soffit Finishes

D1093 Hoists & Cranes

C2023 Stair Handrail &


Balustrade Finishes
C3010 Wall
Finishes

D1091 Dumbwaiters

D1094 Conveyors
D1095 Chutes

C3011 Wall Finishes to Inside


Exterior Walls

D1096 Turntables
C3012 Wall Finishes to Interior
Walls

D1097 Baggage Handling &


Loading Systems

C3013 Column Finishes


D1098 Transportation Systems
C3020 Floor
Finishes

C3021 Floor Toppings


C3022 Traffic Membranes

D2010 Plumbing
Fixtures

D2011 Water Closets


D2012 Urinals

C3023 Hardeners and Sealers


D2013 Lavatories
C3024 Flooring
D2014 Sinks
C3025 Carpeting
D2015 Bathtubs
C3026 Bases, Curbs and Trim
D2016 Wash Fountains
C3027 Access Pedestal
Flooring
C3030 Ceiling
Finishes

C3031 Ceiling Finishes

D2017 Showers
D2018 Drinking Fountains and
Coolers

C3032 Suspended Ceilings

2012 City of Los Angeles. All rights reserved.

Level 3 Elements

Facilities Management Handbook

Page:

12B.2-7

ASTM UNIFORMAT II CLASSIFICATION


FOR BUILDING ELEMENTS (E1557-97)

Date:

01/31/12

Level 4 Sub Elements

Level 3 Elements

D2019 Bidets and Other


Plumbing Fixtures

Level 4 Sub Elements


D3013 Coal Supply System
D3014 Steam Supply System

D2020 Domestic
Water Distribution

D2021 Cold Water Service


D3015 Hot Water Supply
System

D2022 Hot Water Service


D2023 Domestic Water Supply
Equipment

D3016 Solar Energy System


D3017 Wind Energy System

D2030 Sanitary
Waste

D2031 Waste Piping


D2032 Vent Piping

D3021 Boilers

D3020 Heat
Generating
Systems

D3022 Boiler Room Piping &


Specialties

D2033 Floor Drains

D2040 Rain Water


Drainage

D2034 Sanitary Waste


Equipment

D3023 Auxiliary Equipment

D2035 Pipe Insulation

D3024 Insulation

D2041 Pipe & Fittings

D3030 Cooling
Generating
Systems

D3031 Chilled Water Systems

D3040 Distribution
Systems

D3041 Air Distribution Systems

D2042 Roof Drains


D2043 Rainwater Drainage
Equipment

D3042 Exhaust Ventilation


Systems

D2044 Pipe Insulation


D2090 Other
Plumbing Systems

D3032 Direct Expansion


Systems

D2091 Gas Distribution

D3043 Steam Distribution


Systems

D2092 Acid Waste Systems


D3044 Hot Water Distribution
D2093 Interceptors
D3045 Chilled Water
Distribution

D2094 Pool Piping and


Equipment

D3046 Change-over Distribution


System

D2095 Decorative Fountain


Piping Devices

D3047 Glycol Distribution


Systems

D2099 Other Piping Systems


D3010 Energy
Supply

D3011 Oil Supply System

D3050 Terminal &


Package Units

D3051 Terminal Self-Contained


Units

D3012 Gas Supply System


D3052 Package Units

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

Page:

12B.2-8

ASTM UNIFORMAT II CLASSIFICATION


FOR BUILDING ELEMENTS (E1557-97)

Date:

01/31/12

Level 3 Elements

Level 4 Sub Elements

D3060 Controls &


Instrumentation

D3061 Heating Generating


Systems

Level 3 Elements

Ventilation
D3097 General Construction
Items (HVAC)

D3062 Cooling Generating


Systems
D4010 Sprinklers
D3063 Heating/Cooling Air
Handling Units

D4011 Sprinkler Water Supply


D4012 Sprinkler Pumping
Equipment

D3064 Exhaust & Ventilating


Systems
D3065 Hoods and Exhaust
Systems

Level 4 Sub Elements

D4013 Dry Sprinkler System


D4020 Standpipes

D4021 Standpipe Water Supply


D4022 Pumping Equipment

D3066 Terminal Devices


D4023 Standpipe Equipment
D3067 Energy Monitoring &
Control
D3068 Building Automation
Systems

D4024 Fire Hose Equipment


D4030 Fire
Protection
Specialties

D4031 Fire Extinguishers

D4090 Other Fire


Protection Systems

D4091 Carbon Dioxide Systems

D4032 Fire Extinguisher


Cabinets

D3069 Other Controls &


Instrumentation
D3070 Systems
Testing &
Balancing

D3071 Piping System Testing &


Balancing

D4092 Foam Generating


Equipment

D3072 Air Systems Testing &


Balancing

D4093 Clean Agent Systems


D3073 HVAC Commissioning
D4094 Dry Chemical System
D3079 Other Systems Testing
and Balancing
D3090 Other HVAC
Systems &
Equipment

D3091 Special Cooling Systems


& Devices
D3092 Special Humidity Control

D4095 Hood & Duct Fire


Protection
D5010 Electrical
Service &
Distribution

D5012 Low Tension Service &


Dist.

D3093 Dust & Fume Collectors


D3094 Air Curtains

D5020 Lighting &


Branch Wiring

D5021 Branch Wiring Devices


D5022 Lighting Equipment

D3095 Air Purifiers


D3096 Paint Spray Booth

D5011 High Tension Service &


Dist.

D5030
Communications &

D5031 Public Address & Music


Systems

2012 City of Los Angeles. All rights reserved.

Level 3 Elements
Security

Facilities Management Handbook

Page:

12B.2-9

ASTM UNIFORMAT II CLASSIFICATION


FOR BUILDING ELEMENTS (E1557-97)

Date:

01/31/12

Level 4 Sub Elements

Level 3 Elements

D5032 Intercommunication &


Paging System
D5033 Telephone Systems

Level 4 Sub Elements


E1018 Office Equipment

E1020 Institutional
Equipment

E1021 Ecclesiastical Equipment


E1022 Library Equipment

D5034 Call Systems


E1023 Theater & Stage
Equipment

D5035 Television Systems


D5036 Clock and Program
Systems

E1024 Instrumental Equipment


E1025 Audio-visual Equipment

D5037 Fire Alarm Systems


E1026 Detention Equipment
D5038 Security and Detection
Systems

E1027 Laboratory Equipment

D5039 Local Area Networks


D5090 Other
Electrical System

E1028 Medical Equipment

D5091 Grounding Systems


D5092 Emergency Light &
Power Systems

E1029 Other Institutional


Equipment
E1030 Vehicular
Equipment

E1031 Vehicular Service


Equipment

D5093 Floor Raceway Systems


E1032 Parking Control
Equipment

D5094 Other Special Systems &


Devices

E1033 Loading Dock Equipment


D5095 General Construction
Items (Elect.)
E1010 Commercial
Equipment

E1011 Security & Vault


Equipment
E1012 Teller and Service
Equipment
E1013 Registration Equipment
E1014 Checkroom Equipment
E1015 Mercantile Equipment
E1016 Laundry & Dry Cleaning
Equipment
E1017 Vending Equipment

E1039 Other Vehicular


Equipment
E1090 Other
Equipment

E1091 Maintenance Equipment


E1092 Solid Waste Handling
Equipment
E1093 Food Service Equipment
E1094 Residential Equipment
E1095 Unit Kitchens
E1097 Window Washing
Equipment
E1099 Other Equipment

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

Page:

12B.2-10

ASTM UNIFORMAT II CLASSIFICATION


FOR BUILDING ELEMENTS (E1557-97)

Date:

01/31/12

Level 3 Elements

Level 4 Sub Elements

E2010 Fixed
Furnishings

E2011 Fixed Artwork


E2012 Fixed Casework

Level 3 Elements

Construction Systems
F1040 Special
Facilities

F1043 Site Constructed


Incinerators

E2014 Fixed Floor Grilles and


Mats

F1044 Kennels & Animal


Shelters

E2015 Fixed Multiple Seating

F1045 Liquid & Gas Storage


Tanks

E2016 Fixed Interior


Landscaping

F1049 Other Special Facilities

E2021 Movable Artwork


E2022 Furniture & Accessories

F1050 Special
Controls &
Instrumentation

E2023 Movable Rugs and Mats

F1059 Other Special Controls &


Instrumentation

F1011 Air Supported Structures


F1012 Pre-engineered
Structures

F2010 Building
Elements
Demolition

F1021 Integrated Assemblies

F2020 Hazardous
Components
Abatement

F1022 Special Purpose Rooms


F1023 Other Integrated
Construction
F1030 Special
Construction
Systems

F1033 Special Security Systems

F2021 Removal of Hazardous


Components
F2022 Encapsulation of
Hazardous Components

G1010 Site
Clearing

F1031 Sound, Vibration &


Seismic Const.
F1032 Radiation Protection

F2011 Building Interior


Demolition
F2012 Building Exterior
Demolition

F1013 Other Special Structures


F1020 Integrated
Construction

F1051 Recording
Instrumentation
F1052 Building Automation
System

E2024 Movable Interior


Landscaping
F1010 Special
Structures

F1041 Aquatic Facilities


F1042 Ice Rinks

E2013 Blinds and Other


Window Treatment

E2020 Movable
Furnishings

Level 4 Sub Elements

G1011 Clearing & Grubbing


G1012 Tree Removal &
Thinning

G1020 Site
Demolition &
Relocation

G1021 Building Demolition


G1022 Demolition of Site
Components

F1034 Vaults
F1039 Other Special

G1023 Relocation of Building &


Utilities

2012 City of Los Angeles. All rights reserved.

Level 3 Elements

Facilities Management Handbook

Page:

12B.2-11

ASTM UNIFORMAT II CLASSIFICATION


FOR BUILDING ELEMENTS (E1557-97)

Date:

01/31/12

Level 4 Sub Elements

Level 3 Elements

G1024 Utilities Relocation


G1030 Site
Earthwork

G1031 Site Grading Excavation

Level 4 Sub Elements


G2025 Markings & Signage

G2030 Pedestrian
Paving

G2031 Paving & Surfacing

G1032 Borrow Fill

G2032 Edging

G1033 Soil Stabilization &


Treatment

G2033 Exterior Steps


G2034 Pedestrian Bridges

G1034 Site Dewatering


G1035 Site Shoring

G2040 Site
Development

G2041 Fences & Gates


G2042 Retaining Walls

G1036 Embankments
G2043 Terrace & Perimeter
Walls

G1037 Erosion Control


G1040 Hazardous
Waste Remediation

G1041 Removal of
Contaminated Soil

G2044 Signage
G2045 Site Furnishings

G1042 Soil Restoration &


Treatment
G2010 Roadways

G2046 Fountains, Pools, &


Watercourses

G2011 Bases and Sub-Bases


G2047 Playing Fields
G2012 Paving & Surfacing
Structures

G2048 Flagpoles
G2049 Miscellaneous

G2013 Curbs Gutters & Drains


G2014 Guardrails and Barriers
G2015 Painted Lines

G2050
Landscaping

G2051 Fine Grading & Soil


Preparation
G2052 Erosion Control
Measures

G2016 Markings & Signage

G2020 Parking Lots

G2017 Vehicular Bridges

G2053 Top Soil and Planting


Beds

G2021 Bases and Sub-Bases

G2054 Seeding and Sodding

G2022 Paving & Surfacing

G2055 Planting

G2023 Curbs, Rails & Barriers

G2056 Planters

G2024 Parking Booths &


Equipment

G2057 Irrigation Systems


G2059 Other Landscape

2012 City of Los Angeles. All rights reserved.

Level 3 Elements

G3010 Water
Supply

Facilities Management Handbook

Page:

12B.2-12

ASTM UNIFORMAT II CLASSIFICATION


FOR BUILDING ELEMENTS (E1557-97)

Date:

01/31/12

Level 4 Sub Elements

Level 3 Elements

Features

Distribution

G3042 Condensate Return

G3011 Potable Water


Distribution and Storage

G3043 Hot Water Supply


System

G3012 Non Potable Water


Distrib. and Storage
G3013 Well Systems

G3020 Sanitary
Sewer

Level 4 Sub Elements

G3044 Pumping Stations


G3050 Cooling
Distribution

G3051 Chilled Water Piping

G3014 Fire Protection


Distribution and Storage

G3052 Wells for


Cooling/Heating

G3015 Pumping Stations

G3053 Pumping Stations

G3016 Package Water


Treatment Plants

G3054 Cooling Towers on Site

G3021 Piping

G3060 Fuel
Distribution

G3061 Fuel Piping


G3062 Fuel Equipment

G3022 Manholes & Cleanouts


G3063 Fuel Storage Tanks
G3023 Septic Disposal Systems
G3064 Fuel Dispensing Stations
G3024 Lift Stations
G3025 Packaged Water Waste
Treatment Plants

G3090 Other Site


Mechanical Utilities

G3092 POL (Petroleum Oil &


Lubricants) Distribution Systems

G3026 Septic Tanks


G4010 Electrical
Distribution
G3027 Drain Fields
G3030 Storm
Sewer

G3091 Industrial Waste


Systems

G4011 Substations
G4012 Overhead Power
Distribution

G3031 Piping
G4013 Underground Power
Distribution

G3032 Manholes
G3033 Headwalls & Catch
Basins

G4020 Site Lighting

G4021 Fixtures & Transformers


G4022 Poles

G3034 Lift Stations

G3040 Heating

G3035 Retention Ponds

G4023 Wiring Conduits &


Ductbanks

G3036 Ditches & Culverts

G4024 Site Lighting Controls

G3041 Steam Supply

G4030 Site

G4031 Site Communications

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

Page:

12B.2-13

ASTM UNIFORMAT II CLASSIFICATION


FOR BUILDING ELEMENTS (E1557-97)

Date:

01/31/12

Level 3 Elements

Level 4 Sub Elements

Communication &
Security

Systems

Level 3 Elements

Level 4 Sub Elements

G9010 Service &


Pedestrian Tunnels

G9011 Service Tunnels

G4032 Site Security & Alarm


Systems
G4090 Other Site
Electrical Utilities

G4091 Cathodic Protection

G9012 Trench BoxesG9013


Pedestrian Tunnels
G9090 Other Site
Systems

G9091 Snow Melting Systems

G4092 Site Emergency Power


Generation

2012 City of Los Angeles. All rights reserved.

Property Condition Report (PCR)


Table of Contents

1.0

INTRODUCTION ................................................................................. 3

1.1. Purpose ............................................................................................ 3


1.2. Scope of Work ................................................................................. 3

2.0

METHODOLOGY ................................................................................ 4

2.1. Field Team........................................................................................ 4


2.2. Procedures....................................................................................... 4
2.3. Interviews ......................................................................................... 4
2.4. Basis of Cost ................................................................................... 4

3.0

FIELD OBSERVATIONS .................................................................... 5

3.1. Introduction ..................................................................................... 5


3.2. Project Summary ............................................................................. 5
3.3. Civil / Site Development .................................................................. 5
3.4. Pavement ......................................................................................... 5
3.5. Structure and Foundations ............................................................ 5
3.6. Exterior Systems ............................................................................. 5
3.7. Interior Systems .............................................................................. 5
3.8. Vertical Transportation ................................................................... 5
3.9. Mechanical ....................................................................................... 5
3.10. Plumbing Systems .......................................................................... 5
3.11. Fire Protection/Life Safety .............................................................. 5
3.12. Electrical .......................................................................................... 5
3.13. Code Compliance ............................................................................ 5

4.0

REVIEW OF OTHER REPORTS ....................................................... 6

5.0

LIMITATIONS/QUALIFICATIONS .................................................. 7

[Click here and type Project Title:]


[Click here and type Date:]

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-1
02/29/12

Section Contents
Introduction Facility Class ...................................................................................................................... 2
Facility Type Inventory - Buildings ......................................................................................................... 3
Buildings ................................................................................................................................................. 4
A

Substructure .................................................................................................................................... 5
A10
A20

Shell ................................................................................................................................................ 9
B10
B20
B30

Conveying .............................................................................................................................. 43
Plumbing ................................................................................................................................ 47
HVAC ..................................................................................................................................... 54
Fire Protection Systems ........................................................................................................ 67
Electrical ................................................................................................................................ 71

Equipment and Furnishings .......................................................................................................... 93


E10
E20

Interior Construction .............................................................................................................. 28


Stairs ...................................................................................................................................... 32
Interior Finishes ..................................................................................................................... 33

Services ........................................................................................................................................ 39
D10
D20
D30
D40
D50

Superstructure ....................................................................................................................... 12
Exterior Closure ..................................................................................................................... 14
Roofing .................................................................................................................................. 21

Interiors ......................................................................................................................................... 25
C10
C20
C30

Foundations ............................................................................................................................. 5
Basement Construction ........................................................................................................... 7

Equipment .............................................................................................................................. 94
Furnishings ............................................................................................................................ 95

Special Construction & Demolition ............................................................................................... 96


F10
F20
G20

Special Construction .............................................................................................................. 96


Selective Building Demolition ................................................................................................ 96
Site Improvements ............................................................................................................. 97

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-2
02/29/12

Introduction Facility Class


The facility condition assessment should include a complete visual assessment of all architectural,
civil/structural, mechanical, and electrical components of each facility. Perform the field assessment
should be performed using both a system and component assessment method to identify all
maintenance and repair deficiencies that need correction. The engineer/engineering technician
should determine if there is sufficient evidence to warrant complete replacement of a system versus
repairing only system parts (e.g. replacing all the windows in a facility versus repairing some only
windows, or replacing the entire floor covering rather than only repairing only certain parts).
Utilize a systematic approach to visual assessments to document all revealed problems. Some
deficiencies announce themselves, such as a steam leaks or ponding on a roof. However, many
deficiencies are more subtle and will require further examination. During the assessment, the
engineer/engineering technician should thoroughly document the information that will be needed in
the preparation of cost estimates and assessment reports. At a minimum, record the following for
each deficiency:

Specify the corrective action with the appropriate verb (e.g. repair, replace, prepare and
paint, realign, adjust, remove).

Define the deficiency (e.g. cracked window, leaking steam valve packing, missing door
hinge, corroded metal window frame).

Provide location data (e.g. northeast corner of lower roof, in room 123, or in main lobby at
the reception desk).

Quantify data in sufficient detail to permit later development of budget level cost
estimates (e.g. 120 linear feet of 4 steel conduit, or 220 square feet, or 7 each). It is
helpful to determine approximate sizes and types of dynamic equipment such as boilers,
chillers, and pumps.

Note: The results of the visual assessment are not intended be used for capacity planning,
environmental design, etc. If these topics are of particular interest, perform specialized assessments
and analyses.
The following document will provide guidance for the building assessments. At the beginning of each
section, a list of life-cycle estimates will be provided for actions ranging from recurring maintenance
tasks to major system replacements. The life-cycle estimates assume that each component will
experience normal wear-and-tear and that proper maintenance and repair is provided over the life
cycle. Use these estimates as general guidance, noting any deviation based on local conditions or
facility usage as described below.
In some cases, local conditions may alter the life-cycle estimates. For example, under normal
circumstances an electric water heater has an estimated ten-year service life. If the local area has
poor water quality due to high levels of particulate, the expectation might be to replace the water
heaters every five years. The life-cycle estimates may also require alteration due to the different
levels of activity within specific facility usage types. For example, the interior finishes (e.g. paint,
carpet, wallpaper, etc.) in a terminal will likely require replacement more frequently than the finishes
in an administrative building with little traffic. Once again, use the life-cycle estimates as general
guidance and make note of any deviation.

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-3
02/29/12

Facility Type Inventory - Buildings


In addition to gathering deficiency information during the field assessment phase, the
engineer/engineering technician will gather and/or verify information associated with systems and
their components.

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-4
02/29/12

Buildings
Facility Category Buildings is comprised of various different components within the Uniformat II work
breakdown structure (WBS). The authors of the assessment guidance have made a concerted effort
to include every applicable component from the Uniformat II WBS that may be associated with
buildings, thereby producing a self-contained guidance document. The primary systems for buildings
are found in the following Uniformat sections: A - Substructure, B - Shell, C - Interiors, D - Services, E
- Equipment and Furnishings, and F - Special Construction & Demolition.
The assessment guidance for the following subsystems within G - Building Site work is published
separately in various Facility Categories: G10 - Site Preparations, G20 - Site Improvements, G30 Site Mechanical Utilities, G40 - Site Electrical Utilities, and G90 - Other Site Construction.

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-5
02/29/12

Substructure

This system includes all work below the lowest floor construction (usually slab-on-grade) and the
enclosing horizontal and vertical elements required to form a basement, together with the necessary
mass excavation and backfill.

Life-Cycle Estimates:
SUBSTRUCTURES
Item:

Years

Concrete Foundation Walls and


Piers
CMU Block Foundation Walls
and Piers
Brick Foundation Walls and
Piers

40
30
30

Item:

Years

Stone Foundation Walls and


Piers
Wood Foundation Walls and
Piers
Slab on Grade

40
25
40

A10 Foundations
Continuous footings, spread footings, grade beams, foundation walls, pile caps, and column piers.

A1010 Standard Foundations


Lead-Based Paint: About two-thirds of facilities built before 1940 and one-half of facilities
built from 1940 to 1960 contain heavily leaded paint. Some facilities built after 1960 also
contain heavily leaded paint. It may be on any interior or exterior surface, particularly on
woodwork, doors, and windows. In 1978, the U.S. Consumer Product Safety Commission
lowered the legal maximum lead content in most kinds of paint. Formal lead-based paint
assessments require specific equipment and training beyond the scope of a normal condition
assessment. Since the assessments are non-invasive, there is little chance of disturbing any
existing lead-based paint during an assessment. However, when maintenance and repair
scenarios involve the disturbance of the contaminated material (such as removing walls,
doors, and windows; refinishing doors and windows; scrapping paint; etc.), a subsequent cost
factor will determine the need for containing, handling and disposing of the contaminated
material. Facilities constructed before 1980 should be tested for lead if any paint face shows
signs of deterioration or before any renovation that would disturb painted surfaces.

Checks to be made:
1. Exterior surface
Deteriorated paint/waterproofing
Deteriorated/missing caulking
Loose vents
2. Interior surface
Evidence of moisture intrusion
3. Vent screen
Frames - binding, jamming, or poor fit

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-6
02/29/12

Hardware or connections - loose, broken, or missing


Metal parts - rusting or corroding
Fabric - holes or rotting
Wooden parts - rotting and other damage
Vent openings - clogged, blocked, covered, or inadequate ventilated area
resulting in under floor condensation

4. Concrete
Spalling or broken areas
Leaks or dampness
Exposed reinforcing
Out-of-plumb
Differential settlement or frost heave indicated by cracks, binding of doors
and windows, and/or separation of wall or slab from footing
5. Masonry
Eroded or sandy mortar joints
Mortar cracking and pulling away from brick
Soft or spalling brick
Leaks or dampness
Out-of-plumb
Differential settlement or frost heave indicated by cracks, binding of doors
and windows, and/or separation of wall or slab from footing
6. Termites
Termite tubes on or penetrating concrete foundation
Form boards, scrap wood, or other cellulose material under buildings and/or
near foundation or structural wood
7. Drainage
Trash, debris or improper surface grading around structure resulting in water
ponding or surface runoffs draining back towards building

A1020 Special Foundations


All work associated with special foundations including piles, caissons, and any other special
foundation situation.

Checks to be made:
1. Concrete
Spalling or broken areas
Leaks or dampness
Exposed reinforcing
Out-of-plumb
Differential settlement or frost heave indicated by cracks, binding of doors
and windows, and/or separation of wall or slab from footing
2. Masonry
Eroded or sandy mortar joints
Mortar cracking and pulling away from brick
Soft or spalling brick
2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-7
02/29/12

Leaks or dampness
Out-of-plumb
Differential settlement or frost heave indicated by cracks, binding of doors
and windows, and/or separation of wall or slab from footing

3. Termites
Termite tubes on or penetrating concrete foundation
Form boards, scrap wood, or other cellulose material under buildings and/or
near foundation or structural wood.

A1030 Slab on Grade


A slab poured on earth, whether on undisturbed soil or fill soil. Concrete bases may be nonreinforced or reinforced, depending on the load to be supported. Non-reinforced concrete
slabs-on-grade are cast in place and thick enough to provide required strength. Reinforced
concrete slabs-on-grade utilize welded wire mesh or reinforcing rods imbedded in the
concrete to increase resistance to tensile and shear stresses.
Non-reinforced base units may be used as pads under lightweight equipment such as
transformers or heat units, while reinforced bases may be used to support building
components, heavy equipment, etc.
Reinforced concrete pit walls and flooring are poured in place; thickness depends on angle of
repose and weight of supported structures.

Checks to be made:
1. Concrete damage
Cracking, extensive disintegration of surface
Scaling, spalling, popout, and/or vertical displacement
2. Reinforcing steel
Rusting/discoloration evident, cracks occurring parallel to reinforcement
Exposure of reinforcing steel
3. Sealant damage
Deterioration evidenced by hardening of sealant/caulking
Deterioration evidenced by shrinking, cracking or missing sealant/caulking

A20 Basement Construction


A2010 Basement Excavation
Excavation work associated with constructing a basement.

Checks to be made:
1. Excavation and Drainage
Proper grading and drainage around building perimeter

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-8
02/29/12

A2020 Basement Walls


Checks to be made:
1. Interior surface
Evidence of moisture intrusion
2. Concrete
Spalling or broken areas
Leaks or dampness
Exposed reinforcing
Out-of-plumb
Differential settlement or frost heave indicated by cracks, binding of doors
and windows, and/or separation of wall or slab from footing
3. Masonry
Eroded or sandy mortar joints
Mortar cracking and pulling away from brick
Soft or spalling brick
Leaks or dampness
Out-of-plumb
Differential settlement or frost heave indicated by cracks, binding of doors
and windows, and/or separation of wall or slab from footing
4. Termites
Termite tubes on or penetrating concrete foundation
Form boards, scrap wood, or other cellulose material under buildings and/or
near foundation or structural wood

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-9
02/29/12

Shell

This system includes all structural slabs, and decks and supports within basements and above grade.
Note that the structural work will include both horizontal items (slabs, decks, etc.) and vertical
structural components (columns and interior structural walls).

Component Renewal Life-Cycle Estimates:


FLOOR CONSTRUCTION
Item:

Years

Item:

Years

CONCRETE
TERRAZZO
2" X 6" FLOOR JOIST
2" X 8" FLOOR JOIST
2" X 10" FLOOR JOIST
2" X 12" FLOOR JOIST
BRIDGING X TYPE AT FLOOR
JOISTS
PLYWOOD SUBFLOORING
BLANKET INSULATION

75
75
125
125
125
125

PARQUET
HARDWOOD STRIP
WOOD GYM FLOOR
WOOD PLANK
STEEL DECKING
STEEL GRATING

40
40
40
40
30
30

125

GALVANIZED STEEL GRATING

25

125
50

ALUMINUM GRATING

35

Years

Item:

Years

125

2" X 8" ROOF JOIST

125

125
125
125

2" X 10" ROOF JOIST


2" X 10" ROOF JOIST

125
125

Item:

Years

Item:

Years

STUCCO
EIFS
METAL COPING
WOOD LATTICE
ALUMINUM SKIRT SIDING

100
100
30
25
35

25
25
25
25
45

WOOD SKIRT SIDING

25

FIBERGLASS INSULATION

50

BATT INSULATION

50

BRICK

75

CMU
ADOBE

60
75

SOFFIT BOARD
EXTERIOR FASCIA BOARD
WOOD CORNICE
WALL WOOD TRIM
WALL METAL TRIM/FLASHING
GALVANIZED WALL DRIP
EDGE
ALUMINUM WALL DRIP EDGE
RIDGID
POLYSTYRENE/BLUEBOARD
INSULATION
MOLDED BEADBOARD
INSULATION
FIBERBOARD INSULATION
DECORATIVE WOOD

ROOF CONSTRUCTION
Item:
PLYWOOD ROOF
SHEATHING
WOOD ROOF DECKING
STEEL ROOF DECKING
2" X 6" ROOF JOIST
EXTERIOR WALLS

30
35
50
50
50
40

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-10
02/29/12

TERRA COTTA

50

GLASS BLOCK

75

VINYL SIDING

70

ALUMINUM SIDING
WOOD SHEET SIDING
WOOD CLAPBOARD SIDING
WOOD SHINGLE SIDING
GALVANIZED CORRUGATED
SIDING
INSULATED STEEL
SANDWICH SIDING
MASONITE HARD BOARD
SIDING

35
25
25
40

COLUMNS
STRUCTURAL WOOD
COLUMNS
MASONRY COLUMNS
CUT/POINT MASONRY
COLUMNS
SILL PLATE (UP TO 2" X 8")
2" X 4" WOOD STUD
2" X 6" WOOD STUD
2" X 8" WOOD STUD

30

2" X 4" WOOD FRAMING

125

45

2" X 6" WOOD FRAMING

125

12

WALL SHEATHING, PLYWOOD

125

FIBERGLASS PANEL SIDING

WALL SHEATHING, WOOD


FIBERBOARD

125

Years

Item:

Years

20

CASEMENT ALUMINUM

50

20
40
50
45
60
40

CASEMENT STEEL
CASEMENT VINYL CLAD
AWNING WOOD
AWNING ALUMINUM
AWNING STEEL
AWNING VINYL CLAD

45
60
40
50
45
60

Item:

Years

Item:

Years

REPLACE PANIC HARDWARE


REPLACE EXTERIOR METAL
DOOR FRAME
REPLACE EXTERIOR WOOD
DOOR FRAME
REPLACE EXTERIOR WOOD
DOOR
REPLACE EXTERIOR STEEL
DOOR
REPLACE EXTERIOR
ALUMINUM DOOR
ALUMINUM OVERHEAD
DOOR
STEEL ROLLING DOOR
MOTOR OPERATOR,

25

STORE FRONT, ALUMINUM

50

45

REVOLVING, ALUMINUM

25

30

SLIDING, PATIO TYPE

50

30

DOUBLE ACTING,SOLID
CORE, WOOD

30

40

GARAGE, HARDBOARD

45

50

GARAGE, METAL

50

75

GARAGE, WOOD

60

75
25

STEEL, SECTIONAL
WOOD OVERHEAD DOOR

80
60

40
100
25
125
125
125
125

EXTERIOR WINDOWS
Item:
GLAZING COMPOUND IN
WINDOW
NEOPRENE GASKETS
DOUBLE HUNG WOOD
DOUBLE HUNG ALUMINUM
DOUBLE HUNG STEEL
DOUBLE HUNG VINYL CLAD
CASEMENT WOOD
EXTERIOR DOORS

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-11
02/29/12

ROLLING DOOR
ROOF COVERINGS
Item:

Years

Item:

Years

BUILT-UP
MODIFIED BITUMINOUS
SINGLE-PLY/THERMOSET

25
25
20

20
100
10

ROLL ROOFING

20

ASPHALT SHINGLE
WOOD/CEDAR
SLATE

20
40
70

CLAY TILE

70

FIBERGLASS
COPPER
MEMBRANE FLASHING
MODIFIED BITUMINOUS
FLASHING
METAL FLASHING
METAL RIDGE CAP FLASHING
COPPER COUNTER FLASHING
ALUMINUM COUNTER
FLASHING

METAL PANEL

30

Years

Item:

Years

10

CUT/POINT BRICK WALL

25

10

CUT/POINT CMU WALL


CUT/POINT RANDOM STONE
WALL
CUT/POINT CUT STONE WALL
CUT/POINT COPING BLOCKS

25

20
20
30
20
20

Recurring Maintenance Cycles:


EXTERIOR WALLS
Item:
P/P MASONRY/CONCRETE
WALL
P/P STUCCO WALL
P/P WOOD SIDING

20

P/P METAL SIDING


C/C WALL VENT LOUVERS
C/C WALL JOINTS
C/C SEAMS

20
20
20
20

25
25
25

Life-Cycle Estimates:
EXTERIOR WINDOWS
Item:

Years

Item:

Years

P/P METAL WINDOW

C/C AROUND EXTERIOR


WINDOW FRAMES

P/P WOOD WINDOW

EXTERIOR DOORS

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Item:

Years

P/P/REFINISH EXTERIOR
WOOD DOOR
P/P/REFINISH EXTERIOR
METAL DOOR
P/P COMMERCIAL
OVERHEAD METAL DOOR
C/C EXTERIOR DOOR

4
4
4

Item:

Page:
Date:

12B.4-12
02/29/12

Years

P/P COMMERCIAL OVERHEAD


WOOD DOOR
P/P RESIDENTIAL GARAGE
METAL DOOR
P/P RESIDENTIAL GARAGE
WOOD DOOR

4
4
4

B10 Superstructure
B1010 Floor Construction
Checks to be made:
1. Concrete
Wear, pitting, roughness discoloration, stains, settlement, or shrinkage
cracks, particularly where placed over wood framing
Absence of treatment or waxing that would prevent surface dusting
Cracked, chipped, or damage caused by settlement
2. Joists
Warping, checking, splitting, bowing, sagging, or broken members
Deflection
Rotting or fungus growth
Evidence of prolonged dampness
Damage or possible damage to wooden parts due to closeness or direct
contact with soil
Insect damage
3. Subfloor
Warping or sagging
Deflection
Rotting or fungus growth
Evidence of prolonged dampness
Insect damage
4. Insulation
Missing or insufficient insulation
Loose, torn, or damaged facing material
5. Metal Decking / Grating
Wear, rusting, corroding, loose, bent, or other surface damage, and structural
supports, broken welds and loose, missing or damaged bolts, nuts, rivets,
and screws
6. Trench Drains - Concrete
Cracks, spalling, broken areas, settlement, damaged grating

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-13
02/29/12

7. Trench Drains - PVC


Cracks, broken areas, settlement, damaged grating

B1020 Roof Construction


Checks to be made:
1. Roof Rafters, Joists, and Sheathing
Checks, splits, broken members, open joints, loose boards, sag of members,
displacement of joints, insect damage
2. Trusses-Timber
SCOPE: All types of building trusses normally designed for the express purpose
of supporting roof loads (and ceilings, where applicable). All lateral and vertical
bracing and ties between trusses are included.
From ground: twisted and bowed members; excessive number and size of
knots; slope of grain over one inch in ten; checks and splits in ends of web
members; separation or slippage at joints; sag; overloading
From truss: loose bolts, split rings, shear plates, and fastening devises;
checks and splits in bracing, chord members, splice plates (scabs), web
members and filler blocks; missing filler blocks; looseness of tie rods
Steel splice plates: rupture, shearing, crushing, rust
Examine trusses for sagging (Truss Member Identification: Use a sketch of
the truss and label the panel points either numerically or alphabetically)
Wooden parts: dampness and prolonged surface moisture; fungus and
insect (including termite) infestation. Termite and fungus infestations are
often detected prior to actual visual damage by probing with a sharp-pointed
instrument those areas where prolonged dampness is not directly associated
with rainfall or damp climate.
Wooden supports near or at ground level: termite tubes or tunnels; dirt piled
up to wood level
Painted surfaces: blistering, checking, cracking, scaling, wrinkling, flaking,
mildew, bleeding, rust, or corrosion; complete absence of paint, particularly
at ends of members
3. Trusses-Steel
All types of building trusses normally designed for the express purpose of
supporting roof loads (and ceilings, where applicable). All lateral and vertical
bracing and ties between trusses are included.
From ground: twisted, bowed, deformed, or broken members
From truss: loose bolts, rivets, or defective welds
From truss: rupture, shearing, or crushing of steel plates, members, bolts,
and rivets
4. Insulation
Missing or insufficient insulation
Loose, torn, or damaged facing material

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-14
02/29/12

B20 Exterior Closure


B2010 Exterior Walls
Lead-Based Paint: About two-thirds of facilities built before 1940 and one-half of
facilities built from 1940 to 1960 contain heavily leaded paint. Some facilities built
after 1960 also contain heavily leaded paint. It may be on any interior or exterior
surface, particularly on woodwork, doors, and windows. In 1978, the U.S. Consumer
Product Safety Commission lowered the legal maximum lead content in most kinds of
paint. Formal lead-based paint assessments require specific equipment and training
beyond the scope of a normal condition assessment. Since the assessments are
non-invasive, there is little chance of disturbing any existing lead-based paint during
an assessment. However, when maintenance and repair scenarios involve the
disturbance of the contaminated material (such as removing walls, doors, and
windows; refinishing doors and windows; scrapping paint; etc.), a subsequent cost
factor will determine the need for containing, handling and disposing of the
contaminated material. Facilities constructed before 1980 should be tested for lead if
any paint face shows signs of deterioration or before any renovation that would
disturb painted surfaces.
In addition to gathering deficiency information for exterior walls, the
engineer/engineering technician will often gather information specific to the type of
wall. The inventory provides a single-source account of these major components
within an airport. The information inventoried should be:
Unit of Measurement (UOM): SF (of wall)
Additional attribute choices:
1. Wall Material
2. Exterior Finish

Checks to be made:
1. Painting
NOTE: painting of concrete is not recommended unless required for
waterproofing.
Alligatoring, checking, blistering, crawling, cracking, scaling, peeling,
wrinkling, flaking, fading, loss of gloss, excessive chalking, mildew, bleeding,
staining caused by insect screens or splashing, discoloration, complete
absence of paint
2. Weathertightness
Lack of weathertightness, where butting dissimilar surfaces, between joints
3. Parapet Walls and Copings
Cracks, spalling, defective joints and other damage
4. Stucco
Corrosion or disintegration
Alligator cracks
Water stains
Broken areas

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-15
02/29/12

5. Concrete
Cracks, spalling, broken areas, settlement, exposed reinforcing, termite
tubes to wood surfaces
6. Masonry
Eroded or sandy mortar joints
Mortar cracking and pulling away from brick or concrete masonry units
Efflorescence, soft, spalling, or cracked bricks or concrete masonry units
Settlement or expansion cracks
Termite tubes to wood surfaces
7. Siding - Cement/Asbestos
Stains, loose fastenings, or broken sheets
8. Siding Asbestos Shingle
Cracked, missing shingles and deteriorated areas
9. Siding - Aluminum
Corrosion from corrosive atmosphere, loose fastenings, or other damage
10. Siding - Ferrous and Other Metal
Scars, scuffs, rust, corrosion, breaks in protective coatings, puncture of
metal, loose, missing, or broken fastenings
Sagging, buckling, support failure
11. Siding - Wood
Looseness, warping, surface cracking, checking; swelling of joints, loose or
missing knots
Rotting, fungus or termite infestation
Stains
Evidence of prolonged dampness
Skirting and other wooden parts for interference with ventilation and
condensation control
Damage or rot from closeness to soil levels and need for corrective or
preventive treatment
12. Siding - Vinyl
Looseness, warping, surface cracking, missing sections, or other damage
13. Weatherstripping
Lack of weathertightness around framed openings, where butting dissimilar
surfaces, between joints
14. Trim / Flashing - Wood
Looseness
Warping; surface cracking or checking
Swelling of joints
Loose or missing knots
Rotting
Fungus or termite infestation
Stains
2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-16
02/29/12

Evidence of prolonged dampness

15. Wall Insulation


Missing or insufficient insulation
Loose, torn, or damaged facing material
16. Vents/Clean-outs and Chimney Screen
Fly ash clogging; rust, tears, and other damage
Bolts and screws: rust, corrosion, loose, broken, or missing parts
17. Deflection
Rotting or fungus growth
Evidence of prolonged dampness
Damage or possible damage to wooden parts due to closeness or direct
contact with soil
18. Columns - Concrete
Cracks, spalling, broken areas, settlement, or exposed reinforcing
19. Columns - Wood/Timber
Warping, checking, splitting, bowing, sagging, or broken members
20. Columns - Steel
Corrosion, cracking, bowing, settlement
Missing fire proofing
Asbestos fire proofing
21. Columns - Masonry/Stone
Eroded or sandy mortar joints
Mortar cracking and pulling away from brick or concrete masonry units
Efflorescence, soft, spalling, or cracked bricks or concrete masonry units
Settlement or expansion cracks
22. Beams/Girders/Joists/Rafters/Trusses/Studs/Sills
Warping, checking, splitting, bowing, sagging, or broken members
Deflection
Rotting or fungus growth
Evidence of prolonged dampness
Damage or possible damage to wooden parts due to closeness or direct
contact with soil
Insect damage
23. Sheathing
Warping or sagging
Rotting or fungus growth
Evidence of prolonged dampness
Damage or possible damage to wooden parts due to closeness or direct
contact with soil
Insect damage

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-17
02/29/12

B2020 Exterior Windows


Lead-Based Paint: About two-thirds of facilities built before 1940 and one-half of facilities
built from 1940 to 1960 contain heavily leaded paint. Some facilities built after 1960 also
contain heavily leaded paint. It may be on any interior or exterior surface, particularly on
woodwork, doors, and windows. In 1978, the U.S. Consumer Product Safety Commission
lowered the legal maximum lead content in most kinds of paint. Formal lead-based paint
assessments require specific equipment and training beyond the scope of a normal condition
assessment. Since the assessments are non-invasive, there is little chance of disturbing any
existing lead-based paint during an assessment. However, when maintenance and repair
scenarios involve the disturbance of the contaminated material (such as removing walls,
doors, and windows; refinishing doors and windows; scrapping paint; etc.), a subsequent cost
factor will determine the need for containing, handling and disposing of the contaminated
material. Facilities constructed before 1980 should be tested for lead if any paint face shows
signs of deterioration or before any renovation that would disturb painted surfaces.
In addition to gathering deficiency information for exterior windows, the engineer/engineering
technician will often gather information specific to the type of window. The inventory provides
a single-source account of these major components within an airport. The information
inventoried should be:
Unit of Measurement (UOM): EA
Capacities to collect: IN (width), IN (height)
Additional attribute choices:
1. Window Material
2. Operation
3. Insulated (Yes or No)
4. Window Type

Checks to be made:
1. Paint/Caulk/Glaze
Worn/peeling paint
Missing/deteriorated caulking
Missing/loose glazing compound, corrosion, abrasion, loss of finish coating
Broken seals/weather-stripping
Fogging/moisture between panes
2. Glass
Missing or broken panes, disintegration of putty
3. Trim
Looseness, scratches, indentations mechanical damage, personal abuse
4. Adjust/secure
Loose, broken, or missing hardware
Binding, jamming, poor fit of frames
5. Hardware
Loose, missing, broken parts
Binding, misalignment, improper installation or adjustment, lack of lubrication
Corrosion, abrasion, loss of finish coating
2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-18
02/29/12

6. Screens
Loose, broken, or missing hardware
Binding, jamming, poor fit of frames
Metal parts: rust, corrosion, holes in fabric
Wooden parts: rotting, stain, or other damage
7. Shutters
Splitting, rotting, cracking, loose, missing, or misalignment
Freedom of swing or little/no free motion as required
8. Venetian Blinds, Window Shades
Insecure or broken fasteners
Poor operation
Frayed or broken cords or tapes
Broken or damaged slats
Worn or torn material
9. Wood Sash, Frame, Casing and Trim
Splitting, rotting, cracking, loose, poor fit, binding, missing, scratches,
indentations, mechanical damage, personal abuse, loose or missing
caulking, or lack of weathertightness
10. Metal Sash and Trim
Rust, corrosion, warping, binding, poor fit, non-weathertightness
11. Storm Sash
Binding, jamming, poor fit of frames
Metal parts: rust and corrosion
Wood parts: rotting and other damage
12. Wood Sash, Frame, Casing and Trim
Splitting, rotting, cracking, loose, poor fit, binding, missing, loose or missing
caulking, lack of weathertightness
13. Metal Sash and Trim or Metal Storm Sash
Rust, corrosion, warping, binding, poor fit, non-weathertightness

B2030 Exterior Doors


Maintenance (Paint/Caulk/Adjust/Secure/Lubricate):
Lead-Based Paint: About two-thirds of facilities built before 1940 and one-half of facilities
built from 1940 to 1960 contain heavily leaded paint. Some facilities built after 1960 also
contain heavily leaded paint. It may be on any interior or exterior surface, particularly on
woodwork, doors, and windows. In 1978, the U.S. Consumer Product Safety Commission
lowered the legal maximum lead content in most kinds of paint. Formal lead-based paint
assessments require specific equipment and training beyond the scope of a normal condition
assessment. Since the assessments are non-invasive, there is little chance of disturbing any
existing lead-based paint during an assessment. However, when maintenance and repair
scenarios involve the disturbance of the contaminated material (such as removing walls,
doors, and windows; refinishing doors and windows; scrapping paint; etc.), a subsequent cost

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-19
02/29/12

factor will determine the need for containing, handling and disposing of the contaminated
material. Facilities constructed before 1980 should be tested for lead if any paint face shows
signs of deterioration or before any renovation that would disturb painted surfaces.
In addition to gathering deficiency information for exterior doors, the engineer/engineering
technician will often gather information specific to the type of door. The inventory provides a
single-source account of these major components within an airport. The information
inventoried should be:
Unit of Measurement (UOM): EA
Capacities to collect: IN (width)
Additional attribute choices:
1. Door Material
2. Frame Material
3. Door Type - (Standard, Storm, Screen, Overhead, Garage, Other)
4. Door Core/Paint (Solid, Hollow), Painted or Unpainted (note steel doors
may have a non steel core; these are still considered hollow not solid steel)
5. Number of Doors (Single, Double, Other)

General - checks to be made:


1. Wood and Trim
Splitting, rotting, cracking, loose, poor fit, binding, missing, loose or missing
caulking, lack of weathertightness
2. Glass
Missing or broken panes, disintegration of putty
3. Trim
Looseness, scratches, indentations, mechanical damage, personal abuse
4. Paint/Caulk
Worn/peeling paint
Missing/deteriorated caulking
Corrosion, abrasion, loss of finish coating
Broken seals/weather-stripping
5. Adjust/Secure/Lubricate
Loose, broken, or missing hardware
Binding, jamming, poor fit

Components/hardware - checks to be made:


1. Hardware
Loose, missing, broken parts
Binding, misalignment, improper installation or adjustment, lack of lubrication
Corrosion, abrasion, loss of finish coating

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-20
02/29/12

Exterior doors and frames - checks to be made:


1. Wood
Splitting, rotting, cracking, loose, poor fit, binding, missing, scratches,
indentations, loose/damaged hardware, inoperative hardware, mechanical
damage, personal abuse, delimitation, loose or missing caulking, or lack of
weathertightness
2. Metal
Corrosion, warping, binding, poor fit, bent, loose/damaged hardware,
mechanical damage, personal abuse, loose/missing caulking, or lack of
weathertightness
3. Fiberglass
Warping, binding, cracked, poor fit, loose/damaged hardware, mechanical
damage, personal abuse, loose/missing caulking, or lack of weathertightness

Access panels/locks checks to be made:


1. Access Panels/Locks
Corrosion, warping, binding, poor fit, bent, loose/damaged hardware,
mechanical damage, personal abuse

Exterior Doors and Frames:


In addition to gathering deficiency information for overhead doors, the engineer/engineering
technician will often gather information specific to the type of overhead door. The inventory
provides a single-source account of these major components within an airport. The
information inventoried should be:
Unit of Measurement (UOM): EA
Capacities to collect: LF (height), LF (width)
Additional attribute choices:
1. Door Type
2. Door Operation
3. Door Material

Checks to be made:
1. Wood
Splitting, rotting, cracking, loose, poor fit, binding, missing, scratches,
indentations, loose/damaged hardware, inoperative hardware, mechanical
damage, personal abuse, delimitation, loose or missing caulking, or lack of
weathertightness
2. Metal
Corrosion, warping, binding, poor fit, bent, loose/damaged hardware,
mechanical damage, personal abuse, loose/missing caulking, or lack of
weathertightness
3. Fiberglass
Warping, binding, cracked, poor fit, loose/damaged hardware, mechanical
damage, personal abuse, loose/missing caulking, or lack of weathertightness

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-21
02/29/12

B30 Roofing
B3010 Roof Coverings
Lead-Based Paint: About two-thirds of facilities built before 1940 and one-half of facilities
built from 1940 to 1960 contain heavily leaded paint. Some facilities built after 1960 also
contain heavily leaded paint. It may be on any interior or exterior surface, particularly on
woodwork, doors, and windows. In 1978, the U.S. Consumer Product Safety Commission
lowered the legal maximum lead content in most kinds of paint. Formal lead-based paint
assessments require specific equipment and training beyond the scope of a normal condition
assessment. Since the assessments are non-invasive, there is little chance of disturbing any
existing lead-based paint during an assessment. However, when maintenance and repair
scenarios involve the disturbance of the contaminated material (such as removing walls,
doors, and windows; refinishing doors and windows; scrapping paint; etc.), a subsequent cost
factor will determine the need for containing, handling and disposing of the contaminated
material. Facilities constructed before 1980 should be tested for lead if any paint face shows
signs of deterioration or before any renovation that would disturb painted surfaces.
SAFETY: DO NOT walk directly on slate, cement-asbestos, asphalt-roll, or asphalt shingle
roofs. Use ladders or cleated boards to distribute your weight.
In addition to gathering deficiency information for roofs, the engineer/engineering technician
will often gather information specific to the type of roof. The inventory provides a singlesource account of these major components within an airport. The information inventoried
should be:
Unit of Measurement (UOM): SF (each roof)
Additional attribute choices:
1. Roof Type
2. Ballasted or Unballasted

Maintenance - checks to be made:


1. Painting
Alligatoring, checking, blistering, crawling, cracking, scaling, peeling,
wrinkling, flaking, fading, loss of gloss, excessive chalking, mildew, bleeding,
staining caused by insect screens or splashing, discoloration, complete
absence of paint
2. Exposed metal surfaces
NOTE: Painting of concrete is not recommended unless required for
waterproofing.
Need for rust removal and painting or protective coating

Roof covering, general - checks to be made:


1. Roof surface and drains
Trash and debris

Roof covering, single-ply membrane (elastomeric) - checks to be made:


1. Membrane surface
Deterioration, cracking, splitting, and cuts

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-22
02/29/12

2. Side and end lap seams


Separation and failure
3. Ballasted roof system
Loss of stone cover
4. Roof edge flashing
Pulled loose or missing
5. Adhered membrane system
Separated from fasteners

Roof covering, wood shingles - checks to be made:


1. Shingles
Weathering, warped, broken, loose, split, curling, missing, or flashing failures
Rotted decking or dampness: where possible, without damaging roof
covering, use screwdriver to probe under edge of roof covering at overhang
to conduct check
2. Wall, vent, valley, and edge flashing
Open joints, loose, proper fastenings, and other damage

Roof covering, built-up - checks to be made:


1. Built-up
Cracking, alligatoring, low spots and water ponding
Failure or lack of gravel stops
Cracks in membrane
Exposed bituminous coating
Exposed, disintegrated, blistered, curled, or buckled felts
2. Fastenings
Improper materials, loose, missing, broken, defective, exposure
3. Pitch pockets/pans
Replenishment of pitch

Roof covering, other materials - checks to be made:


1. Clay tile
Weathering, broken, missing, cracked, loose, flashing failures
Deterioration of expansion joint material or tile rising from improper placing or
inadequate expansion joints.
2. Slate
Weathering, broken, cracked, loose, missing, flashing failures
3. Metal
Holes, looseness, punctures, broken seams, inadequate side and end laps,
inadequate expansion joints
Rust or corrosion and damage resulting from contact of dissimilar metals
2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-23
02/29/12

4. Cement-Asbestos
Wear from weathering, broken, cracked, loose, missing, insufficient side or
end lap
5. Asphalt-Roll
Weathering, cracking, alligatoring, buckling, blistering, insufficient or uncemented laps, tearing from nails too close to edge, other damage to coating
6. Asphalt-Shingle
Weathering, lifting, cracking, curling, buckling, blistering, loss of granules,
excessive exposure
7. Asbestos Shingles
Weathering, broken, cracked, loose, missing, sufficient side or end lap
8. Concrete Slabs
Cracks, sapling, expansion joint deterioration, low spots, improper drainage

Flashing general checks to be made:


1. Metal base flashing
Rust, open vertical joints, loose flanges, inadequate or exposed nailing,
improper fastening, improper sealing with felt strips, deteriorated or missing
cant strip
2. Other base flashing
Sagging, deteriorating, separation, adequate coverage or embedment,
vertical joints, proper fastening, buckling, cracking, surface coat, cant strip
3. Metal cap flashing
Rust, corrosion, open joints, loose, improper fastenings

Flashing - other cap flashings checks to be made:


1. General
Open joints, buckling, cracking
Surface coat disintegration
Improper fastenings

Expansion joints/ballast material/debris checks to be made:


1. Expansion joints
Holes, deteriorated/missing caulking, missing/loose fasteners, deteriorated
membrane
2. Ballast material
Missing ballast material
3. Debris
Debris on roof surface

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-24
02/29/12

Drainage checks to be made:


1. Gutters and Downspouts
Misalignment, rust, corrosion, material accumulations and clogging, breaks,
leaks, missing wire guards, loose or missing hangars or other fastenings
Failure to connect downspouts to available storm sewers, or terminate on
properly installed splash blocks

B3020 Roof Openings


Checks to be made:
1. Hatches/Smoke Hatches/Skylights
Splitting, cracking, improperly installed, weathertightness, rusting or
inoperative hardware.

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-25
02/29/12

Interiors

Interiors are defined by construction that takes place inside the exterior wall or exterior skin. The
system does not include interior structural walls, which are included in System B, Superstructure.

Component Renewal Life-Cycle Estimates:


INTERIOR PARTITIONS
Item:

Years

DRYWALL

75

PLASTER

75

WOOD PANELING

30

VINYL WALL COVERING

15

WALLPAPER

20

ACOUSTIC WALL TILE

60

Item:

Years

STRUCTURAL FACING TILE

75

PAINTED CMU WALL


PAINTED BRICK WALL
BENCH, WOOD
BENCH, ALUMINUM
BENCH, CAST IRON
BENCH, WOOD SLATS/
STEEL PEDESTALS

75
75
30
25
20

PAINTED TERRA COTTA


BLOCK WALL
GLASS BLOCK WALL
CUT/POINT PAINTED BRICK
WALL
CUT/POINT PAINTED CMU
WALL
WATER CLOSET PARTITION,
PAINTED METAL
WATER CLOSET PARTITION,
MARBLE
WATER CLOSET PARTITION
STAINLESS STEEL
BASE CABINET, HARDWOOD
BASE CABINET, WOOD
WALL CABINETS, WOOD
WARDROBE, PLASTIC
LAMINATE
BASE CABINET, METAL
WALL CABINETS, METAL
COUNTERTOP, PLASTIC
COUNTERTOP, STAINLESS
BLEACHERS, ALUMINUM

30

BLEACHERS, WOOD

30

BENCH, CONCRETE

75

Years

Item:

Years

40

REPLACE INTERIOR HOLLOW


CORE WOOD DOOR

30

Item:

Years

ACOUSTIC CARPET WALL


COVERING
CORK
CERAMIC WALL TILE
MARBLE

10
16
75
75

75
75
25
25
20
50
75
100
100
100
70
20
20
70
75
25

INTERIOR DOORS
Item:
REPLACE INTERIOR SOLID
CORE WOOD DOOR
REPLACE INTERIOR METAL
DOOR

60

STAIRWAYS
Item:

Years

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

CONCRETE STAIR TREAD


INSERTS
RUBBER/VINYL STAIR
TREAD
RUBBER STAIR NOSING
ANTI-SLIP ABRASIVE TREAD
TAPE
BRICK TREAD
TERRAZZO TREAD
CLAY/QUARRY TILE TREAD

Page:
Date:

12B.4-26
02/29/12

30

WOOD STAIR TREAD

40

18

METAL GRATE TREAD

30

STONE TREAD

50

WOOD RAILING

40

50
50
50

STEEL PIPE RAILING


WROUGHT IRON RAILING

45
45

Item:

Years

Item:

Years

PARQUET
HARDWOOD STRIP
WOOD GYM FLOOR
WOOD PLANK
STEEL DECKING
STEEL GRATING
GALVANIZED STEEL
GRATING
ALUMINUM GRATING
SEALER/HARDENER
SILICONE BASE ON
CONCRETE
EPOXY COAT/FILM TO
CONCRETE

40
40
40
40
30
30

VINYL
RUBBER
CORK
CERAMIC TILE
NATURAL CLAY/QUARRY TILE
MARBLE TILE

18
18
16
50
50
50

25

SLATE TILE

70

35

SHEET VINYL

18

10

FLOOR MAT, IN-LAID BLACK


RUBBER

18

15

TERRAZZO

75

Item:

Years

Item:

Years

SUSPENDED ACOUSTIC
SUSPENDED MINERAL FIBER
HARDBOARD PANELS
PLYWOOD

50
50
50
50

40
75
50
50

FINISHED WOOD STRIP

50

SHEETROCK/DRYWALL
PLASTER
SPRAYED ACOUSTICAL
ROLLED BATT INSULATION
BLOWN-IN FIBERGLASS
INSULATION

INTERIOR FLOORS

INTERIOR CEILINGS

50

Recurring Maintenance Cycle Estimates:


INTERIOR PARTITIONS

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-27
02/29/12

Item:

Years

Item:

Years

P/P WALLS AND


CEILINGS(CONCRETE/DRY
WALL/PLASTER)

P/P WOOD WATER CLOSET


STALL

P/P METAL WALL

P/P WOOD

10

P/P/STAIN CABINETS AND


CASEWORK
P/P METAL WATER CLOSET
STALL

P/P REFINISH INTERIOR


WOOD TRIM
P/P REFINISH WOOD
WAINSCOT
C/C AT WALL AND COUNTER
TOP

4
4
7

C/C PLUMBING FIXTURE

Years

Item:

Years

INTERIOR DOORS
Item:
P/P/REFINISH INTERIOR
WOOD DOOR
P/P/REFINISH INTERIOR
METAL DOOR

4
4

P/P/REFINISH WATER CLOSET


WOOD DOOR
P/P WATER CLOSET METAL
DOOR

4
4

STAIRWAYS
Item:

Years

Item:

Years

P/P METAL STAIRS


P/P CONCRETE STAIRS
P/P/STAIN WOOD STAIRS

7
7
7

7
7
8

P/P METAL PIPE RAIL

P/P/STAIN WOOD STAIR RAIL

P/P WROUGHT IRON RAIL


P/P METAL STAIR RAILING
RUBBER STAIR NOSING
ANTI-SLIP ABRASIVE TREAD
TAPE
CARPET

Years

Item:

Years

10

CARPET

15

CARPET TILE

10

10
10

ANTI-SLIP TAPE
P/P STONE

8
10

Item:

Years

Item:

Years

P/P INTERIOR CEILING

P/P METAL CEILING/DECKING

8
8

INTERIOR FLOORS
Item:
SEALER/HARDENER
SILICONE BASE ON
CONCRETE
EPOXY COAT/FILM TO
CONCRETE
P/P CONCRETE
P/P WOOD
INTERIOR CEILINGS

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-28
02/29/12

CONCRETE/DRYWALL/
PLASTER
P/P/FINISH INTERIOR WOOD

P/P INTERIOR CEILING/


PIPES/UTILITIES/GIRDERS

C10 Interior Construction


C1010 Interior Partitions
Drywall/plaster/paneling - checks to be made:
1. Wallboard, plasterboard, hard pressed fiberboard, and cement-asbestos
board
Open joints, cracking, buckling, sagging, support failure, loose, failure of
nailing or adhesive, abrasions, breaks, holes
Discoloration from weather or utility leaks
2. Plaster
Cracking, buckling, sagging, support failure
Spalling, crumbling, or falling from moisture absorption
Efflorescence, peeling, or flaking from moisture or sealer failure
Discoloration from weather or utility leaks
3. Wood
Checking, cracking, splintered, broken, warping, sagging, support failure, rot
Insect (including termite) or fungus infestation
Abrasion, scuff marks, mechanical damage, personal abuse
4. Soft fiberboard (acoustical and insulation)
Open joints, buckling, sagging, support failure, loose, missing, failure of
fastenings or adhesive, abrasions, breaks, holes
5. Metal
Corrosion, rust abrasions, indentations, punctures, deterioration of protective
coating

Ceramic tile/masonry/glass block - checks to be made:


1. Ceramic tile/masonry/glass block
Chipped, cracked, loose, missing, holes, defective mortar joints
Etched, pitted or dull surfaces caused by use of acidulous or abrasive
cleaners

Trim - checks to be made:


1. Wood
Missing, cracking, splintered, broken, warping, rot
Insect (including termite) or fungus infestation
Abrasion, scuff marks, personal abuse
2. Resilient (linoleum, vinyl plastic)

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-29
02/29/12

Curling, loose, adhesive failure, abrasions, indentations, punctures, tears


Etched, pitted, or dull surfaces caused by use of acidulous or abrasive
cleaner
Evidence of mechanical damage or personal abuse

3. Ceramic/porcelain/marble
Chipped, cracked, loose, missing, holes, defective mortar joints
Etched, pitted or dull surfaces caused by use of acidulous or abrasive
cleaners

Mirrors/fixtures - checks to be made:


1. Mirrors
Missing, cracking, broken, abrasion, deteriorated backing, missing/damaged
mounting hardware
2. Fixtures
Missing, loose, inoperative, bent, or other damage

Corner guards/rub rails - checks to be made:


1. Wood
Missing, loose, cracked, warped, damaged/missing hardware, worn finish
2. Metal
Missing, bent, damaged/missing hardware, worn finish
3. Resilient (vinyl plastic)
Curling, loose, adhesive failure, abrasions, indentations, punctures, tears
Etched, pitted, or dull surfaces caused by use of acidulous or abrasive
cleaner
Evidence of mechanical damage or personal abuse

C1020 Interior Doors


General - checks to be made:
1. Wood and Trim
Splitting, rotting, cracking, loose, poor fit, binding, missing
2. Glass
Missing or broken panes, disintegration of putty
3. Trim
Looseness, scratches, indentations mechanical damage, personal abuse
Maintenance (Paint/Caulk/Adjust/Secure/Lubricate):
Lead-Based Paint: About two-thirds of facilities built before 1940 and one-half of facilities
built from 1940 to 1960 contain heavily leaded paint. Some facilities built after 1960 also
contain heavily leaded paint. It may be on any interior or exterior surface, particularly on
woodwork, doors, and windows. In 1978, the U.S. Consumer Product Safety Commission
lowered the legal maximum lead content in most kinds of paint. Formal lead-based paint
assessments require specific equipment and training beyond the scope of a normal condition
2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-30
02/29/12

assessment. Since the assessments are non-invasive, there is little chance of disturbing any
existing lead-based paint during an assessment. However, when maintenance and repair
scenarios involve the disturbance of the contaminated material (such as removing walls,
doors, and windows; refinishing doors and windows; scrapping paint; etc.), a subsequent cost
factor will determine the need for containing, handling and disposing of the contaminated
material. Facilities constructed before 1980 should be tested for lead if any paint face shows
signs of deterioration or before any renovation that would disturb painted surfaces.

Checks to be made:
1. Paint/caulk
Worn/peeling paint
Missing/deteriorated caulking
Corrosion, abrasion, loss of finish coating
2. Adjust/secure/lubricate
Loose, broken, or missing hardware
Binding, jamming, poor fit

Components/hardware - checks to be made:


1. Hardware
Loose, missing, broken parts
Binding, misalignment, improper installation or adjustment, lack of lubrication
Corrosion, abrasion, loss of finish coating

Interior doors and frames - checks to be made:


1. Wood
Splitting, rotting, cracking, loose, poor fit, binding, missing, scratches,
indentations, loose/damaged hardware, inoperative hardware, mechanical
damage, personal abuse, delimitation
2. Metal
Corrosion, warping, binding, poor fit, bent, loose/damaged hardware,
mechanical damage, personal abuse

C1030 Fittings
Miscellaneous partitions - checks to be made:
1. Wood
Missing, cracking, splintered, broken, warping, rot, abrasion, scuff marks,
deteriorated paint/finish
Evidence of mechanical damage or personal abuse
Missing/damaged hardware
2. Metal
Missing, loose, indentations, bent, corrosion, deteriorated paint/finish
Evidence of mechanical damage or personal abuse
Missing/damaged hardware
3. Marble

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-31
02/29/12

Missing, cracked, loose, holes


Etched, pitted or dull surfaces caused by use of acidulous or abrasive
cleaners
Missing/damaged hardware

Water closet partitions - checks to be made:


1. Wood
Missing, cracking, splintered, broken, warping, rot, abrasion, scuff marks,
deteriorated paint/finish
Evidence of mechanical damage or personal abuse
Missing/damaged hardware
2. Metal
Missing, loose, indentations, bent, corrosion, deteriorated paint/finish
Evidence of mechanical damage or personal abuse
Missing/damaged hardware
3. Marble
Missing, cracked, loose, holes
Etched, pitted or dull surfaces caused by use of acidulous or abrasive
cleaners
Missing/damaged hardware
4. Phenolic
Missing, cracked, loose
Etched, pitted or dull surfaces caused by use of acidulous or abrasive
cleaners
Missing/damaged hardware

Toilet/shower/tub doors and hardware - checks to be made:


1. Wood
Splitting, rotting, cracking, loose, poor fit, binding, missing, scratches,
indentations, loose/damaged hardware, inoperative hardware, mechanical
damage, personal abuse, delimitation
2. Metal
Corrosion, warping, binding, poor fit, bent, loose/damaged hardware,
mechanical damage, personal abuse
3. Marble
Missing, cracked, loose, holes
Etched, pitted or dull surfaces caused by use of acidulous or abrasive
cleaners
Missing/damaged hardware
4. Phenolic
Missing, cracked, loose, holes
Etched, pitted or dull surfaces caused by use of acidulous or abrasive
cleaners
Missing/damaged hardware

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-32
02/29/12

Cabinets/counters - checks to be made:


1. Wood
Missing, cracking, splintered, broken, warping, rot, abrasion, scuff marks,
deteriorated paint/finish
Evidence of mechanical damage or personal abuse
Missing/damaged hardware
2. Metal
Missing, loose, indentations, bent, corrosion, deteriorated paint/finish
Evidence of mechanical damage or personal abuse
Missing/damaged hardware

C20 Stairs
C2010 Stair Construction
Treads - checks to be made:
1. Risers and treads
Wear, splintered, split, cracked, chipped, loose, broken, sagging, rotted,
damage to supporting structure, or damage caused by settlement
2. Finished treads
Absence of protective coatings
Evidence of insect infestation in finish and supporting members
Inadequate exposure of abrasive necessary for non-slip finish surfaces
Loose, missing, broken, or other damage to abrasive stair nosing or treads
Lack of non-slip finish or other types of stair covering
3. Steel
Wear, rusted, loose, bent, or other damage to surfaces, risers, treads, and
structural supports

Stairs/landings - checks to be made:


4. Concrete
Cracks, spalling, broken areas, settlement, exposed reinforcing
5. Masonry/Stone
Eroded or sandy mortar joints
Mortar cracking and pulling away from brick or concrete masonry units
Efflorescence, soft, spalling, or cracked bricks or concrete masonry units
Settlement or expansion cracks
6. Wood
Missing, loose, cracked, warped, damaged/missing hardware, worn finish

Railing balustrade - checks to be made:


1. Hand railing and supports
Lack of rigidity of supporting members

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-33
02/29/12

Loose, splintered, missing, or other damage to handrails, lattices, and


supports
Absence of protective coatings

2. Metal railings
Rust, loose, bent, or other damage to surfaces and structural supports
Broken welds and loose, missing or damaged bolts, nuts, rivets and screws

C2020 Stair Finishes


Maintenance (Paint/Secure):
Lead-Based Paint: About two-thirds of facilities built before 1940 and one-half of facilities
built from 1940 to 1960 contain heavily leaded paint. Some facilities built after 1960 also
contain heavily leaded paint. It may be on any interior or exterior surface, particularly on
woodwork, doors, and windows. In 1978, the U.S. Consumer Product Safety Commission
lowered the legal maximum lead content in most kinds of paint. Formal lead-based paint
assessments require specific equipment and training beyond the scope of a normal condition
assessment. Since the assessments are non-invasive, there is little chance of disturbing any
existing lead-based paint during an assessment. However, when maintenance and repair
scenarios involve the disturbance of the contaminated material (such as removing walls,
doors, and windows; refinishing doors and windows; scrapping paint; etc.), a subsequent cost
factor will determine the need for containing, handling and disposing of the contaminated
material. Facilities constructed before 1980 should be tested for lead if any paint face shows
signs of deterioration or before any renovation that would disturb painted surfaces.

Checks to be made:
1. Painting
NOTE: Painting of concrete is not recommended unless required for
waterproofing.
Alligatoring, checking, blistering, crawling, cracking, scaling, peeling,
wrinkling, flaking, fading, loss of gloss, excessive chalking, mildew, bleeding,
staining caused by insect screens or splashing, discoloration, complete
absence of paint. Paint film is less than three mils in thickness on metal
surfaces.

Tread inserts/covering/anti-slip treatment - checks to be made:


1. Abrasive Tape
Missing, loose, worn/torn
2. Metal
Missing, bent, damaged/missing hardware, worn surface, worn finish/paint

C30 Interior Finishes


C3010 Wall Finishes
Maintenance (Paint/Caulk/Secure/Seal):
Lead-Based Paint: About two-thirds of facilities built before 1940 and one-half of facilities
built from 1940 to 1960 contain heavily leaded paint. Some facilities built after 1960 also
contain heavily leaded paint. It may be on any interior or exterior surface, particularly on

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-34
02/29/12

woodwork, doors, and windows. In 1978, the U.S. Consumer Product Safety Commission
lowered the legal maximum lead content in most kinds of paint. Formal lead-based paint
assessments require specific equipment and training beyond the scope of a normal condition
assessment. Since the assessments are non-invasive, there is little chance of disturbing any
existing lead-based paint during an assessment. However, when maintenance and repair
scenarios involve the disturbance of the contaminated material (such as removing walls,
doors, and windows; refinishing doors and windows; scrapping paint; etc.), a subsequent cost
factor will determine the need for containing, handling and disposing of the contaminated
material. Facilities constructed before 1980 should be tested for lead if any paint face shows
signs of deterioration or before any renovation that would disturb painted surfaces.

Checks to be made:
1. Painting
NOTE: Painting of concrete is not recommended unless required for
waterproofing.
Alligatoring, checking, blistering, crawling, cracking, scaling, peeling,
wrinkling, flaking, fading, loss of gloss, excessive chalking, mildew, bleeding,
staining caused by insect screens or splashing, discoloration, complete
absence of paint. Paint film is less than three mils in thickness on metal
surfaces.

Wall coverings - checks to be made:


1. Resilient coverings (linoleum, vinyl plastic)
Curling, loose, adhesive failure, abrasions, indentations, punctures, tears
Etched, pitted, or dull surfaces caused by use of acidulous or abrasive
cleaner
Evidence of mechanical damage or personal abuse
2. Canvas and paper covering
Breaks, wrinkling, fading, adhesive failure
Evidence of mechanical damage or personal abuse

C3020 Floor Finishes


General - checks to be made:
1. All finished flooring
Overloading
Absence of protective coatings
Evidence of insect infestation in finish and subflooring indicated by presence
of sawdust, wood pellets, or small round emergence holes
Prolonged dampness could contain infestation and fungus growth
Maintenance (Paint/Caulk/Penetration/Secure):
Lead-Based Paint: About two-thirds of the facilities built before 1940 and one-half of the
facilities built from 1940 to 1960 contain heavily leaded paint. Some facilities built after 1960
also contain heavily leaded paint. It may be on any interior or exterior surface, particularly on
woodwork, doors, and windows. In 1978, the U.S. Consumer Product Safety Commission
lowered the legal maximum lead content in most kinds of paint. Formal lead-based paint
assessments require specific equipment and training that is beyond the scope of a normal
condition assessment. Since the assessments are non-invasive, there is little chance of

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-35
02/29/12

disturbing any existing lead-based paint during an assessment. However, when maintenance
and repair scenarios involve the disturbance of the contaminated material (such as removing
walls, doors and windows; refinishing doors and windows; scrapping paint; etc.), a cost factor
will be developed to reflect the need for containing, handling and disposing of the
contaminated material. Facilities constructed before the 1980s should be tested for lead
before any renovation that would disturb painted surfaces or if any paint face shows signs of
deterioration.

Checks to be made:
1. Painting
Alligatoring, checking, blistering, crawling, cracking, scaling, peeling,
wrinkling, flaking, fading, loss of gloss, excessive chalking, mildew, bleeding,
staining caused by insect screens or splashing, discoloration, complete
absence of paint. Paint film is less than three mils in thickness on metal
surfaces.

Terrazzo - checks to be made:


1. Terrazzo
Wear, pitting, roughness, discoloration, settlement cracks

Wood floors - checks to be made:


1. Wood
Sagging, wear, splintered, loose, warped, scratched, shrinkage cracks,
rotted, stains, discoloration, moisture penetration, indentations
Absence of protective coatings
Evidence of insect infestation in finish and subflooring indicated by presence
of sawdust, wood pellets, or small round emergence holes
Prolonged dampness could contain infestation and fungus growth
2. Strip and plank
Sagging, wear, splintered, loose, warped, scratched, shrinkage cracks,
rotted, stains, discoloration, moisture penetration, indentations
3. End-grain block
Loose, missing, rotted or otherwise damaged individual blocks that form
uneven surfaces

Masonry/stone - checks to be made:


1. Clay, quarry tile, brick
Sandy and eroded mortar joints
Individually stained, broken, chipped, or loose, resulting in uneven surfaces

Access flooring - checks to be made:


1. Tiles, carpet or vinyl
Panels fit properly in frame
Pedestals are proper height and are securely anchored

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-36
02/29/12

Carpet - checks to be made:


1. Carpets and rugs
Wear, tear, cuts, raveling, discoloration, fading
Binding or anchoring strips for wear, damage, poor anchorage
Worn or missing tractive substance on backing of small rugs or carpets
where placed over polished floor
Beetle or moth damage

Tile, soft - checks to be made:


1. Resilient floor coverings (linoleum, vinyl plastic, vinyl asbestos, cork,
rubber, and asphalt tiles)
Wear, cracking, shipping, breaking, scratches, tears, indentations
Lack of bonding and unevenness underlayment
Evidence of damage resulting from use of solvents or excessive water use
for cleaning
Absence of protective wax coatings

Tile, hard - checks to be made:


1. Ceramic, porcelain, marble, clay
Cracking, chipping, breaking, scratches
Lack of bonding and unevenness underlayment
Evidence of damage resulting from use of solvents or excessive water use
for cleaning
Absence of protective sealant

Sheet covering/abrasive strips/mats - checks to be made:


1. Resilient floor coverings (linoleum, vinyl plastic, vinyl asbestos, cork,
rubber
Wear, cracking, chipping, breaking, scratches, tears, indentations

Lack of bonding and unevenness underlayment

Evidence of damage resulting from use of solvents or excessive water use


for cleaning

Absence of protective wax coatings

C3030 Ceiling Finishes


Maintenance (Paint/Secure):
Lead-Based Paint: About two-thirds of facilities built before 1940 and one-half of facilities
built from 1940 to 1960 contain heavily leaded paint. Some facilities built after 1960 also
contain heavily leaded paint. It may be on any interior or exterior surface, particularly on
woodwork, doors, and windows. In 1978, the U.S. Consumer Product Safety Commission
lowered the legal maximum lead content in most kinds of paint. Formal lead-based paint
assessments require specific equipment and training beyond the scope of a normal condition
assessment. Since the assessments are non-invasive, there is little chance of disturbing any
existing lead-based paint during an assessment. However, when maintenance and repair
scenarios involve the disturbance of the contaminated material (such as removing walls,
doors, and windows; refinishing doors and windows; scrapping paint; etc.), a subsequent cost
factor will determine the need for containing, handling and disposing of the contaminated
2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-37
02/29/12

material. Facilities constructed before 1980 should be tested for lead if any paint face shows
signs of deterioration or before any renovation that would disturb painted surfaces.

Checks to be made:
1. Painting
NOTE: Painting of concrete is not recommended unless required for
waterproofing.
Alligatoring, checking, blistering, crawling, cracking, scaling, peeling,
wrinkling, flaking, fading, loss of gloss, excessive chalking, mildew, bleeding,
staining caused by insect screens or splashing, discoloration, complete
absence of paint
2. Metal
Corrosion, rust, abrasions, indentations, punctures, deterioration of protective
coating

Tile - checks to be made:


1. Ceramic Tile
Chipped, cracked, loose, missing, holes, defective mortar joints
Etched, pitted or dull surfaces caused by use of acidulous or abrasive
cleaners

Sheetrock/plaster - checks to be made:


1. Plaster
Cracking, buckling, sagging, support failure
Spalling, crumbling, or falling from moisture absorption
Efflorescence, peeling, or flaking from moisture or sealer failure
Discoloration from weather or utility leaks
2. Wallboard, plasterboard, hard pressed fiberboard, and cement-asbestos
board
Open joints, cracking, buckling, sagging, support failure, loose, failure of
nailing or adhesive, abrasions, breaks, holes, discoloration from weather or
utility leaks
3. Soft fiberboard (acoustical and insulation)
Open joints, cracking, buckling, sagging, support failure, loose, failure of
nailing or adhesive, abrasions, breaks, holes, discoloration from weather or
utility leaks

Sprayed material & insulation - checks to be made:


1. Insulation
Loose/missing sections, damaged facing material, insufficient thickness or Rvalue
2. Sprayed material
Loose/missing/flaking sections, damaged areas, insufficient thickness

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-38
02/29/12

Concrete - checks to be made:


1. Concrete
Cracks, spalling, broken areas, settlement, exposed reinforcing

Wood - checks to be made:


1. Wood
Checking, cracking, splintered, broken, warping, sagging, support failure, rot
Insect (including termite) or fungus infestation
Abrasion, scuff marks, mechanical damage, personal abuse

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-39
02/29/12

Services

Life-Cycle Estimates:
CONVEYING SYSTEMS
Item:

Years

Item:

Years

HYDRAULIC ELEVATOR
TRACTION ELEVATOR
ESCALATOR

25
25
15

DUMBWAITER
BELT CONVEYOR

20
5

Item:

Years

Item:

Years

LAVATORY

40

25

SINK

40

GARBAGE DISPOSAL

SERVICE SINK

35

FAUCET

10

BATHTUB, FIBERGLASS

20

BATHTUB, PE ON CI

40

BATHTUB, ENAMELED STEEL

35

SHOWER, ENAMELED STEEL


SHOWER, FIBERGLASS
TUB/SHOWER MIXING VALVE
WALL MOUNTED, WATER
COOLER
WATER CLOSET
URINAL

35
20
10

FLUSH VALVE
ELECTRIC TO 50 Gallon, HOT
WATER GENERATOR
ELECTRIC 80 - 2000 GAL, HOT
WATER GENERATOR
GAS/OIL TO 50 GAL, HOT
WATER GENERATOR
GAS/OIL 50 TO 70 GAL, HOT
WATER GENERATOR
GAS/OIL COMMERCIAL, HOT
WATER GENERATOR
HEAT EXCHANGER, SHELL/
TUBE, HOT WATER
GENERATOR
STORAGE TANK, DOMESTIC
HOT WATER, HOT WATER
GENERATOR
AIR COMPRESSOR
REFRIGERATED
VACUUM PUMP UNIT
VACUUM PUMP SINGLE
STAGE COMPRESSOR
VACUUM PUMP MOTOR

PLUMBING

10
35
35

10
15
10
12
20
20

50
25
15
25
25
25

HEATING
Item:

Years

Item:

Years

GAS/OIL FIRED, BOILERS


ELECTRIC, BOILERS

30
15

15
20

BURNER, BOILERS

BURNER MOTOR, BOILERS

SOLAR PANEL
SOLAR STORAGE TANK
CENTRIFUGAL PUMP/ MOTOR
SET, SOLAR ENERGY
SHELL & TUBE, HEAT
EXCHANGER

20
30

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

UNDERGROUND FUEL OIL


STORAGE UNIT, BOILERS
GAS/OIL, FURNACES

Page:
Date:

20

CIRCULATING (SET)

15

15

10

ELECTRIC, FURNACES

15

FURNACE FAN MOTOR


STEAM/HOT WATER,
RADIANT HEATERS
FIN TUBE STEAM/HOT
WATER, RADIANT HEATERS
ELECTRIC BASEBOARD,
RADIANT HEATERS

10

MOTOR, CIRCULATING
PUMP,HEAD(EXCLUDES
MOTOR), CIRCULATING
FUEL OIL PUMP, BOILER

50

PUMP SEALS

20

FAN COIL UNIT

15

20

FAN MOTOR

10

GAS FIRED, UNIT HEATERS

15

STEAM/HOT WATER, UNIT


HEATERS

15

ELECTRIC, UNIT HEATERS

20

GAS FIRED, INFRARED


HEATERS
ELECTRIC, INFRARED
HEATERS

15
15

DX HEAT PUMP, AIR


HANDLING UNITS
HOT WATER STEAM, AIR
HANDLING UNITS
FAN MOTOR, AIR HANDLING
UNITS
COOLING COIL, AIR
HANDLING UNITS
HEATING COIL, AIR HANDLING
UNITS

12B.4-40
02/29/12

15
7

20
15
10
25
25

Life-Cycle Estimates:
COOLING
Item:

Years

PUMP-DOWN COMPRESSOR,
CENTRIFUGAL CHILLER

10

AIR COOLED,
RECIPROCATING CHILLER
WATER COOLED,
RECIPROCATING CHILLER
COMPRESSOR,
RECIPROCATING CHILLER
CONDENSER COIL,
RECIPROCATING CHILLER
CONDENSER FAN MOTOR,
RECIPROCATING CHILLER
AIR COOLED/GAS FIRED,
ABSORPTION CHILLER
WATER COOLED,
ABSORPTION CHILLER
BURNER BLOWER,
ABSORPTION CHILLER
CIRCULATING PUMP,
ABSORPTION CHILLER

20
20
10
10

Item:

Years

FLUID COOLER CIRCULATING


PUMP, AIR COOLED
CONDENSER
FORCED DRAFT, COOLING
TOWER
FAN MOTOR, COOLING
TOWER
FLOAT VALVE, COOLING
TOWER
AIR CONDITIONER, WINDOW
UNIT

14
15
10
10
10

10

EVAPORATIVE CONDENSER

15

20

CONDENSER FAN MOTOR

10

20

CIRCULATING PUMP

10

EVAPORATIVE COOLER

12

14

DX WATER/GLYCOL COOLED

20

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

DX AIR COOLED, SPLIT


SYSTEM
DX, COMPRESSOR, SPLIT
SYSTEM
CONDENSER COIL, SPLIT
SYSTEM
DX, FAN MOTOR, SPLIT
SYSTEM
PACKAGE UNIT,
HORIZONTAL, SELFCONTAINED
PACKAGE UNIT, FREE
STANDING, WATER COOLED
DX COMPRESSOR,
ROOFTOP UNIT
AIR COOLED CONDENSER
COIL, ROOFTOP UNIT
WATER COOLED
CONDENSER, ROOFTOP
UNIT
FAN MOTOR, ROOFTOP UNIT
HOT WATER/STEAM
HEATING COIL, ROOFTOP
UNIT
GAS FURNACE IN ROOFTOP
PACKAGE UNIT
DIRECT DRIVE, AIR COOLED
CONDENSER
FAN MOTOR, AIR COOLED
CONDENSER

Page:
Date:

20

DX COMPRESSOR

10

10

EVAPORATOR FAN MOTOR

10

10

AIR COMPRESSOR

25

10

AIR COMPRESSOR MOTOR

15

15

CENTRIFUGAL PUMP/ MOTOR


SET

20

15

CIRCULATING MOTOR

15

10

FAN COIL UNIT

15

10

FAN MOTOR

10

10

FAN MOTOR

15

10

COOLING COIL, DX

10

25

COOLING COIL, CHILLED


WATER

25

15

HEATING COIL, HOT WATER

25

12B.4-41
02/29/12

10

SYSTEM (CONTROL PANEL,


SENSORS, CHEMICAL PUMPS
CHEMICAL PUMPS

Item:

Years

Item:

Years

RELIEF VENTILATOR
FAN MOTOR

20
10

FAN, ROOF/WALL EXHAUST

15

Item:

Years

Item:

Years

DRY PIPE/DELUGE

100

WET PIPE
TRIM PACKAGE, AND
RETARDING VALVE
COMPRESSED GAS
CYLINDER, CO2

100

15

15
15

VENTILATION

EXTINGUISHING SYSTEMS

100
25

DRY CHEMICAL EXPELLANT


CYLINDER
WET CHEMICAL CYLINDER
COMMERCIAL KITCHEN HOOD
FIRE EXTINGUISHING SYSTEM
AIR COMPRESSOR, DRY
PIPE/DELUGE

25
25
25
25

Life-Cycle Estimates:

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-42
02/29/12

ELECTRICAL SERVICE AND DISTRIBUTION


Item:

Years

Item:

Years

SERVICE ENTRANCE, CABLE


1 POLE MOLDED CASE,
CIRCUIT BREAKER
2 POLE MOLDED CASE,
CIRCUIT BREAKER
3 POLE MOLDED CASE,
CIRCUIT BREAKER
ELECTRICAL METALLIC
TUBE, CONDUIT
600 AMP, FUSES
ELECTRICAL SERVICE,
GROUNDING
BUILDING STRUCTURE,
GROUNDING
LIGHTNING PROTECTION,
GROUNDING

30

GROUND ROD

25

50

3ASCR, OVERHEAD SERVICE

30

50

SAFETY SWITCHES

25

50

SWITCHBOARDS

20

25

LIQUID FILLED,
TRANSFORMERS
DRY, TRANSFORMERS

50

8" X 8", WIREWAY

20

50

MOTOR STARTER

18

Years

Item:

Years

20

METAL HALIDE BALLAST,


LIGHT FIXTURE

10

10

QUARTZ, LIGHT FIXTURE

20

20

EXIT LIGHT

20

50

30
30

25

ELECTRICAL LIGHTING AND POWER


Item:
FLUORESCENT INTERIOR,
LIGHT FIXTURE
FLUORESCENT BALLAST,
LIGHT FIXTURE
INCANDESCENT, LIGHT
FIXTURE
METAL HALIDE, LIGHT
FIXTURE

20

ELECTRICAL SPECIAL SYSTEMS


Item:

Years

Item:

Years

PULL STATION

15

25

SMOKE DETECTOR

15

HEAT DETECTOR

15

ANNUNCIATOR PANEL
CONTROL PANEL
ALARM BELL

15
15
20

GENERATOR SETS
BATTERY CHARGER,
GENERATOR SET
UPS BATTERY, GENERATOR
SET
TRANSFER SWITCH
COIL, TRANSFER SWITCH

20
15
18
5

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-43
02/29/12

D10 Conveying
D1010 Elevators and Lifts
Hydraulic Elevators
Users Comment:
Ask maintenance personnel for comments on performance and condition of elevator
before starting assessment.
In addition to gathering deficiency information for elevators, the engineer/engineering
technician will often gather information specific to the type of elevator. The inventory
provides a single-source account of these major components within an airport. The
information inventoried should be:
Unit of Measurement (UOM): EA
Capacities to collect: LB, ST (stops)
Additional attribute choices:
1. Type
2. Use

Checks to be made:
1. Hydraulic Elevators
Operational cab doors, leveling, smoothness of ride, or smell of hydraulic
fluid
Loose, disconnected, missing, or damaged cab components
Loose, missing, damaged, or inoperative electrical components or call
stations
Excessive noise and vibration from hydraulic pump unit
Reason for out of service message

Traction Elevators
Users Comment:
Ask maintenance personnel for comments on performance and condition of elevator
before starting assessment.
In addition to gathering deficiency information for elevators, the engineer/engineering
technician will often gather information specific to the type of elevator. The inventory
provides a single-source account of these major components within an airport. The
information inventoried should be:
Unit of Measurement (UOM): EA
Capacities to collect: LB, ST (stops)
Additional attribute choices:
1. Type
2. Use

Checks to be made:
1. Traction Elevators
Operational cab doors, leveling, or smoothness of ride

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-44
02/29/12

Loose, disconnected, missing, or damaged cab components


Loose, missing, damaged, or inoperative electrical components or call
stations
Excessive noise and vibration from drive assembly or motor generator
Damaged or deteriorated hoist wire ropes
Reason for out of service message

D1020 Escalators and Moving Walks


Escalators
Users Comment:
Ask maintenance personnel for comments on performance and condition of escalator
before starting assessment.
In addition to gathering deficiency information for escalators, the engineer/engineering
technician will often gather information specific to the type of escalator. The inventory
provides a single-source account of these major components within an airport. The
information inventoried should be:
Unit of Measurement (UOM): EA
Capacities to collect: LF (length), LF (width)
Additional attribute choices:
1. Type (Vertical or Horizontal)

Checks to be made:
1. Escalators
Variable speed of handrails, smoothness of ride, and levelness of foot plates
Loose, disconnected, missing, or damaged components
Loose, missing, damaged, or inoperative electrical components
Excessive noise and vibration during operation
Reason for out of service message

D1090 Other Conveying Systems


Dumbwaiters
Users Comment:
Ask maintenance personnel for comments on performance and condition of dumbwaiter
before starting assessment.
In addition to gathering deficiency information for dumbwaiters, the engineer/engineering
technician will often gather information specific to the type of dumbwaiter. The inventory
provides a single-source account of these major components within an airport. The
information inventoried should be:
Unit of Measurement (UOM): EA
Capacities to collect: LB, ST (stops)
Additional attribute choices:
1. Type
2. Use

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-45
02/29/12

Checks to be made:
1. Dumbwaiters
Operation of cab doors, leveling, or smoothness of ride
Loose, disconnected, missing, or damaged cab components
Loose, missing, damaged, or inoperative electrical components or call
stations
Excessive noise and vibration from drive assembly or motor generator
Reason for out of service message

Belt Conveyors
Users Comment:
Ask maintenance personnel for comments on performance and condition of belt conveyor
before starting assessment.
In addition to gathering deficiency information for conveyors, the engineer/engineering
technician will often gather information specific to the type of conveyor. The inventory
provides a single-source account of these major components within an airport. The
information inventoried should be:
Unit of Measurement (UOM): EA
Capacities to collect: LF (length), LF (width)

Checks to be made:
1. Belt conveyors
Rust damage, oil leak, loose, missing, or damaged parts, and deteriorated
surfaces
Damaged frame, worn belt, and improper belt tracking
Loose, missing, damaged, or inoperative electrical components
Excessive noise and vibration from drive assembly or gear motor
Aged, deteriorated, or inoperative belt conveyor

Roller Conveyors
Users Comment:
Ask maintenance personnel for comments on performance and condition of roller
conveyor before starting assessment.
In addition to gathering deficiency information for conveyors, the engineer/engineering
technician will often gather information specific to the type of conveyor. The inventory
provides a single-source account of these major components within an airport. The
information inventoried should be:
Unit of Measurement (UOM): EA
Capacities to collect: LF (length), LF (width)

Checks to be made:
1. Roller conveyors
Rust damage, oil leak, loose, missing, or damaged parts, and deteriorated
surfaces
Damaged frame
Loose, missing, damaged, or inoperative electrical components

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-46
02/29/12

Excessive noise and vibration from drive assembly or gear motor


Aged, deteriorated, or inoperative conveyor

Pneumatic Tube System


Users Comment:
Ask maintenance personnel for comments on performance and condition of pneumatic
tube system before starting assessment.

Checks to be made:
1. Pneumatic tube system
Rust damage, air leak, loose, missing, or damaged parts, and deteriorated
surfaces
Damaged tubes, supports, or hangers
Loose, missing, damaged, or inoperative electrical components
Excessive noise and vibration from blower or motor
Aged, deteriorated, or inoperative blower assembly

Bridge Cranes
Users Comment:
Ask maintenance personnel for comments on performance and condition of bridge crane
before starting assessment.

Checks to be made:
1. Bridge cranes
Rust damage, leaking hydraulic fluid, loose, missing, or damaged parts,
deteriorated surfaces, and missing identifiers of bridge crane and runway or
trolley and bridge rails
Loose, missing, damaged, or inoperative electrical components, operator
stations or devices
Excessive noise and vibration from bridge crane or trolley gear motor drive
units or hoist motor
Damaged or deteriorated hoist, wire rope, block or hook
Aged, deteriorated, or inoperative bridge crane or trolley

Jetways
Users Comment:
Ask maintenance personnel for comments on performance and condition of jetways
before starting assessment.
In addition to gathering deficiency information for jetways, the engineer/engineering
technician will often gather information specific to the type of jetway. The inventory provides
a single-source account of these major components within an airport. The information
inventoried should be:
Unit of Measurement (UOM): EA
Capacities to collect: LF (length), LF (width)

Checks to be made:
1. Jetways

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-47
02/29/12

Rust damage, oil leak, loose, missing, or damaged parts, and deteriorated
surfaces
Damaged frame
Loose, missing, damaged, or inoperative electrical components
Excessive noise and vibration from drive assembly or gear motor
Aged, deteriorated, or inoperative conveyor

D20 Plumbing
D2010 Plumbing Fixtures
Checks to be made:
1. Maintenance
Loose fixtures, water leaks
Loose, missing, deteriorated, or damaged components, hangers, or fittings
Inadequate or excessive water flow
Slow or clogged drains
2. Lavatories/sinks (including wash fountains, utility sinks, and laundry sinks)
Aged, deteriorated or damaged fixture and/or accessories
3. Bathtubs/showers
Aged, deteriorated or damaged fixture and/or accessories
4. Water coolers
Aged, deteriorated or damaged fixture and/or components
5. Water closets/urinals/bidets
Aged, deteriorated or damaged fixture and/or accessories

D2020 Domestic Water Distribution


Checks to be made:
1. Maintenance
Rust damage, water leaks
Loose, missing, or damaged parts, mounts, hangers, or fittings
Deteriorated surfaces, missing identifier, or blocked access

Hot Water Generators


This includes hot water heaters, shell and tube hot water generators, hot water storage tanks,
and swimming pool heaters.
Users Comment:
Ask maintenance personnel for comments on performance and condition of hot water
generator before starting assessment.
In addition to gathering deficiency information for water heaters, the engineer/engineering
technician will often gather information specific to the type of water heater. The inventory
provides a single-source account of these major components within an airport. The
information inventoried should be:
2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-48
02/29/12

Unit of Measurement (UOM): EA


Capacities to collect: GA, MBH
Additional attribute choices:
1. Fuel Type

Checks to be made:
1. Hot water generators
Rust damage, fuel leaks, water leaks, excessive noise and vibration
Loose, disconnected, missing, or damaged parts
Damaged or loose electrical connections
Damaged or missing insulation
Aged, deteriorated, damaged, or inoperative hot water generator

Piping, Fittings, Valves


In addition to gathering deficiency information for valves, the engineer/engineering technician
will often gather information specific to the type of valve. The inventory provides a singlesource account of these major components within an airport. The information inventoried
should be:
Unit of Measurement (UOM): EA
Capacities to collect: IN
Additional attribute choices:
1. Type
2. Operating Mechanism
3. Material
4. Rating
5. Connection Type
6. Location

Checks to be made:
1. Piping, fittings, valves
Condition of pipes, fittings, valves, hangers, supports, backflow preventers,
master water temperature control valve and pipe insulation

Pumps
In addition to gathering deficiency information for pumps, the engineer/engineering technician
will often gather information specific to the type of pump. The inventory provides a singlesource account of these major components within an airport. The information inventoried
should be:
Unit of Measurement (UOM): EA
Capacities to collect: HP, GPM
Additional attribute choices:
1. Type
2. Material
3. Power/Fuel Source
4. Mounting Method

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-49
02/29/12

Checks to be made:
1. Pumps
Rust damage, water leaks, excessive noise and vibration
Loose, missing, or damaged parts
Condition of motor, coupling, and pump
Damaged or missing pump insulation
Damaged or loose electrical connections
Aged, deteriorated, or inoperative pump

D2030 Sanitary Waste


Checks to be made:
1. Maintenance
Rust damage, water leaks, clogged drain
Loose, missing, or damaged parts, hangers, supports, or fittings
Deteriorated surfaces, missing identifier, or blocked access

Ejectors and Pumps


In addition to gathering deficiency information for pumps, the engineer/engineering technician
will often gather information specific to the type of pump. The inventory provides a singlesource account of these major components within an airport. The information inventoried
should be:
Unit of Measurement (UOM): EA
Capacities to collect: HP, GPM
Additional attribute choices:
1. Type
2. Material
3. Power/Fuel Source
4. Mounting Method

Checks to be made:
1. Ejectors and pumps
Rust damage, leaks, excessive noise and vibration
Loose, missing, or damaged parts
Condition of motor and pump
Condition of floats and controllers
Damaged or loose electrical connections
Aged, deteriorated, or inoperative pump

Piping and Fittings


Checks to be made:
1. Piping and fittings
Condition of pipes, fittings and valves
Aged or abandoned piping

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-50
02/29/12

D2040 Rain Water Drainage


Checks to be made:
1. Maintenance
Loose fixtures, water leaks
Loose, missing, deteriorated, or damaged components, hangers, or fittings
Inadequate or excessive water flow
Slow or clogged drains

Ejectors and pumps


In addition to gathering deficiency information for pumps, the engineer/engineering technician
will often gather information specific to the type of pump. The inventory provides a singlesource account of these major components within an airport. The information inventoried
should be:
Unit of Measurement (UOM): EA
Capacities to collect: HP, GPM
Additional attribute choices:
1. Type
2. Material
3. Power/Fuel Source
4. Mounting Method

Checks to be made:
1. Ejectors and pumps
Rust damage, leaks, excessive noise and vibration
Loose, missing, or damaged parts
Condition of motor and pump
Condition of floats and controllers
Damaged or loose electrical connections
Aged, deteriorated, or inoperative pump

Piping and fittings


Checks to be made:
1. Piping and fittings
Condition of pipes, fittings and valves
Aged or abandoned piping

D2090 Other Plumbing Systems


Compressed Air Maintenance
Checks to be made:
1. Maintenance
Rust damage, air leaks

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-51
02/29/12

Loose, missing, deteriorated, or damaged components, mounts, hangers, or


fittings
Deteriorated surfaces, missing identifier, or blocked access

Compressed Air Air Compressors


In addition to gathering deficiency information for air compressors, the engineer/engineering
technician will often gather information specific to the type of air compressor. The inventory
provides a single-source account of these major components within an airport. The
information inventoried should be:
Unit of Measurement (UOM): EA
Capacities to collect: HP, PSI
Required capacities (estimating notes if required): HP rating of motor and
maximum PSI rating observed at storage tank gauge.
Additional attribute choices:
1. Air Drier (Yes or No)
2. Air Control Type (Dual or Single)
3. Tank Capacity
4. Compressor Use

Checks to be made:
1. Air compressors
Rust damage, oil leaks, air leaks
Loose, missing, deteriorated, or damaged components
Condition of tank, motors, belts, compressors and condensate drain system
Continuous running or too-frequent cycling
Aged, deteriorated, or inoperative

Compressed Air Dryers


Checks to be made:
1. Dryers
Rust damage, oil/refrigerant leaks, water leaks, excessive noise and vibration
Loose, missing, or damaged parts
Debris collected on intake side of condenser coils
Condition motor and fan
Damaged or loose electrical connections
Aged, deteriorated, or inoperative

Compressed Air Piping, Fittings, Valves


In addition to gathering deficiency information for valves, the engineer/engineering technician
will often gather information specific to the type of valve. The inventory provides a singlesource account of these major components within an airport. The information inventoried
should be:
Unit of Measurement (UOM): EA
Capacities to collect: IN
Additional attribute choices:
2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

1.
2.
3.
4.
5.
6.

Page:
Date:

12B.4-52
02/29/12

Type
Operating Mechanism
Material
Rating
Connection Type
Location

Checks to be made:
1. Piping, fittings, valves
Rust damage, air leaks
Loose, missing, deteriorated, or damaged components, filters and oil
separators
Condition of pipes, fittings, valves, hangers and supports

Vacuum System Maintenance


Checks to be made:
1. Maintenance
Rust damage, air leaks
Loose, missing, deteriorated, or damaged components, mounts, hangers, or
fittings
Deteriorated surfaces, missing identifier, or blocked access

Vacuum System Vacuum Pumps


Checks to be made:
1. Vacuum pumps
Rust damage, oil leaks, air leaks
Loose, missing, deteriorated, or damaged components
Condition of tank, motors, belts and air compressors
Continuous running or too-frequent cycling
Aged, deteriorated, or inoperative

Vacuum System Piping, Fittings, Valves


In addition to gathering deficiency information for valves, the engineer/engineering technician
will often gather information specific to the type of valve. The inventory provides a singlesource account of these major components within an airport. The information inventoried
should be:
Unit of Measurement (UOM): EA
Capacities to collect: IN
Additional attribute choices:
1. Type
2. Operating Mechanism
3. Material
4. Rating
5. Connection Type
6. Location

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-53
02/29/12

Checks to be made:
1. Piping, fittings, valves
Rust damage, air leaks
Loose, missing, deteriorated, or damaged components
Condition of pipes, fittings, valves, hangers and supports

Indus/Med Gas Maintenance


Checks to be made:
1. Maintenance
Rust damage, leaks
Loose, missing, deteriorated, or damaged components, mounts, hangers, or
fittings
Deteriorated surfaces, missing identifier, or blocked access

Indus/Med Gas Storage Vessels


Checks to be made:
1. Storage vessels
Rust damage, air leaks
Loose, missing, deteriorated, or damaged components
Deteriorated or missing insulation

Indus/Med Gas Piping, Fittings, Valves


In addition to gathering deficiency information for valves, the engineer/engineering technician
will often gather information specific to the type of valve. The inventory provides a singlesource account of these major components within an airport. The information inventoried
should be:
Unit of Measurement (UOM): EA
Capacities to collect: IN
Additional attribute choices:
1. Type
2. Operating Mechanism
3. Material
4. Rating
5. Connection Type
6. Location

Checks to be made:
1. Piping, fittings, valves
Rust damage, air leaks
Loose, missing, deteriorated, or damaged components
Condition of pipes, fittings, valves and pipe insulation

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-54
02/29/12

D30 HVAC
D3010 Energy Supply
Fuel Storage
Checks to be made:
1. Fuel storage
Rust damage, fuel leaks
Loose, disconnected, missing, or damaged parts
Condition of storage tank, frame, and supports
Damaged or missing insulation
Damaged or loose electric heater connections
Damaged or missing fuel spill containment system

Piping, Fittings, Valves


In addition to gathering deficiency information for valves, the engineer/engineering technician
will often gather information specific to the type of valve. The inventory provides a singlesource account of these major components within an airport. The information inventoried
should be:
Unit of Measurement (UOM): EA
Capacities to collect: IN
Additional attribute choices:
1. Type
2. Operating Mechanism
3. Material
4. Rating
5. Connection Type
6. Location

Checks to be made:
1. Piping, fittings, valves
Condition of pipes, fittings, valves, hangers, or supports and pipe insulation
Aged or abandoned piping

D3020 Heat Generating Systems


Maintenance
Users Comment:
Ask maintenance personnel for comments on performance and condition of the heating
components before starting assessment.

Checks to be made:
1. Maintenance
Rust damage, fuel leaks, water leaks, excessive noise and vibration
Loose, disconnected, missing, or damaged parts

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-55
02/29/12

Boilers, Gas/Oil/Electric
Users Comment:
Ask maintenance personnel for comments on performance and condition of boiler before
starting assessment.
In addition to gathering deficiency information for boilers, the engineer/engineering technician
will often gather information specific to the type of boiler. The inventory provides a singlesource account of these major components within an airport. The information inventoried
should be:
Unit of Measurement (UOM): EA
Capacities to collect: MBH, PSI
Additional attribute choices:
1. Boiler Type
2. Fuel Type
3. Boiler Style

Checks to be made:
1. Boilers, gas/oil/electric
Rust damage, fuel leaks, water leaks, excessive noise and vibration
Loose, disconnected, missing, or damaged parts
Aged or deteriorated burner/blower
Damaged or missing insulation
Damaged or loose electrical connections
Aged, deteriorated, or obsolete boiler

Furnaces, Gas/Oil/Electric
Users Comment:
Ask maintenance personnel for comments on performance and condition of furnace
before starting assessment.
In addition to gathering deficiency information for furnaces, the engineer/engineering
technician will often gather information specific to the type of furnace. The inventory provides
a single-source account of these major components within an airport. The information
inventoried should be:
Unit of Measurement (UOM): EA
Capacities to collect: MBH
Additional attribute choices:
1. Cooling Coil (Yes or No)
2. Furnace Fuel Type

Checks to be made:
1. Furnaces, gas/oil/electric
Rust damage, fuel leaks, excessive noise and vibration
Loose, disconnected, missing, or damaged parts
Damaged or loose electrical connections
Aged, deteriorated, or inoperative furnace

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-56
02/29/12

Radiant Heaters Steam/Hot Water/Gas


Checks to be made:
1. Radiant heaters steam/hot water/gas
Rust damage, fuel leaks, excessive noise and vibration
Loose, disconnected, missing, or damaged parts
Damaged or loose electrical connections
Aged, deteriorated, or inoperative radiant heater

Unit Heaters Gas/Steam/Electric


Checks to be made:
1. Unit heaters gas/steam/electric
Rust damage, fuel leaks, excessive noise and vibration
Loose, disconnected, missing, or damaged parts
Inoperative motor or damaged fan
Damaged or missing hangers or supports
Damaged or loose electrical connections
Aged, deteriorated, or inoperative unit heater

Infrared Heaters Gas/Electric


Checks to be made:
1. Infrared heaters gas/electric
Rust damage, fuel leaks, excessive noise and vibration
Loose, disconnected, missing, or damaged parts
Damaged or missing hangers or supports
Damaged or loose electrical connections
Aged, deteriorated, or inoperative infrared heater

Solar Energy
Checks to be made:
1. Solar energy
Rust damage, fuel leaks, excessive noise and vibration
Loose, disconnected, missing, or damaged parts
Condition of panels, pump, piping and insulation
Damaged or missing supports
Damaged or loose electrical connections
Deteriorated or inoperative solar heater

Pumps, Circulating
In addition to gathering deficiency information for pumps, the engineer/engineering technician
will often gather information specific to the type of pump. The inventory provides a singlesource account of these major components within an airport. The information inventoried
should be:
Unit of Measurement (UOM): EA

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-57
02/29/12

Capacities to collect: HP, GPM


Additional attribute choices:
1. Type
2. Material
3. Power/Fuel Source
4. Mounting Method

Checks to be made:
1. Pumps, circulating
Rust damage, water leaks, excessive noise and vibration
Loose, missing, or damaged parts
Condition of motor, coupling, and pump
Damaged or missing pump insulation
Damaged or loose electrical connections
Aged, deteriorated, or inoperative pump

Fan Coil Units Hot Water


Checks to be made:
1. Fan coil units hot water
Rust damage, water leaks, excessive noise and vibration
Loose, missing, or damaged parts
Inoperative motor or damaged fan/blower
Aged, deteriorated, inoperative, or abandoned fan coil unit

Piping, Fittings, Valves


In addition to gathering deficiency information for valves, the engineer/engineering technician
will often gather information specific to the type of valve. The inventory provides a singlesource account of these major components within an airport. The information inventoried
should be:
Unit of Measurement (UOM): EA
Capacities to collect: IN
Additional attribute choices:
1. Type
2. Operating Mechanism
3. Material
4. Rating
5. Connection Type
6. Location

Checks to be made:
1. Piping, fittings, valves
Condition of pipes, fittings, valves, hangers, or supports and pipe insulation
Aged or abandoned piping

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-58
02/29/12

Chemical Water Treatment


Checks to be made:
1. Chemical water treatment
Condition of controller, sensors, pumps, pipes, fittings and valves

D3030 Cooling Generating Systems


Maintenance
Checks to be made:
1. Maintenance
Rust damage, air leaks, water leaks
Loose, missing, or damaged parts, mounts, hangers, or fittings
Deteriorated surfaces, missing identifier, or blocked access

Centrifugal Chillers
Users Comments:

Ask maintenance personnel for comments on performance and condition of chiller before
starting assessment.

In addition to gathering deficiency information for chillers, the engineer/engineering technician


will often gather information specific to the type of chiller. The inventory provides a singlesource account of these major components within an airport. The information inventoried
should be:
Unit of Measurement (UOM): EA
Capacities to collect: TN
Additional attribute choices:
1. Chiller Type
2. Condenser Type
3. Coolant Type
4. Power Source
5. Water Treated (Yes or No)

Checks to be made:
1. Centrifugal Chillers
Rust damage, oil leaks, water leaks, excessive noise and vibration
Loose, disconnected, missing, or damaged parts
Damaged or missing insulation
Type of refrigerant used in system
Aged, deteriorated, high maintenance or inoperative chiller

Reciprocating Chillers
Users Comment:
Ask maintenance personnel for comments on performance and condition of chiller before
starting assessment.

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-59
02/29/12

In addition to gathering deficiency information for chillers, the engineer/engineering technician


will often gather information specific to the type of chiller. The inventory provides a singlesource account of these major components within an airport. The information inventoried
should be:
Unit of Measurement (UOM): EA
Capacities to collect: TN
Additional attribute choices:
1. Chiller Type
2. Condenser Type
3. Coolant Type
4. Power Source
5. Water Treated (Yes or No)

Checks to be made:
1. Water cooled reciprocating chiller
Rust damage, oil leaks, water leaks, excessive noise and vibration
Loose, disconnected, missing, or damaged parts
Damaged or missing insulation
Type of refrigerant used in system
Aged, deteriorated, high maintenance or inoperative chiller
2. Air cooled reciprocating chiller
Rust damage, oil leaks, water leaks, excessive noise and vibration
Loose, disconnected, missing, or damaged parts
Damaged or missing insulation
Debris collected on intake side of condenser coils or fans bent or out of
balance
Type of refrigerant used in system
Aged, deteriorated, high maintenance or inoperative chiller

Absorption Chillers
Users Comment:
Ask maintenance personnel for comments on performance and condition of chiller before
starting assessment.
In addition to gathering deficiency information for chillers, the engineer/engineering technician
will often gather information specific to the type of chiller. The inventory provides a singlesource account of these major components within an airport. The information inventoried
should be:
Unit of Measurement (UOM): EA
Capacities to collect: TN
Additional attribute choices:
1. Chiller Type
2. Condenser Type
3. Coolant Type
4. Power Source
5. Water Treated (Yes or No)

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-60
02/29/12

Checks to be made:
1. Absorption chillers
Rust damage, water leaks, excessive noise and vibration
Loose, disconnected, missing, or damaged parts
Aged, deteriorated, high maintenance or inoperative chiller

Split System
Users Comment:
Ask maintenance personnel for comments on performance and condition of system
before starting assessment.

Checks to be made:
1. Split system
Rust damage, oil/refrigerant leaks, excessive noise and vibration
Loose, missing, or damaged parts
Debris collected on intake side of condenser coils
Condition motors and fans
Damaged or loose electrical connections
Damaged refrigerant piping or missing pipe insulation
Type of refrigerant used in system
Aged, deteriorated, or inoperative system

DX Split System Condenser Units/Heat Pumps


Users Comment:
Ask maintenance personnel for comments on performance and condition of condenser
before starting assessment.

Checks to be made:
1. Condenser, air cooled
Rust damage, oil/refrigerant leaks, excessive noise and vibration
Loose, missing, or damaged parts
Debris collected on intake side of condenser coils
Condition motors and fans
Damaged or loose electrical connections
Damaged refrigerant piping or missing pipe insulation
Type of refrigerant used in system
Aged, deteriorated, or inoperative condenser
2. Condenser, water cooled
Rust damage, oil/refrigerant leaks, excessive noise and vibration
Loose, missing, or damaged parts
Damaged or loose electrical connections
Damaged refrigerant piping or missing pipe insulation
Type of refrigerant used in system
Aged, deteriorated, or inoperative condenser
Water leaks or stoppages in condenser water
Loose rusted corroded condenser piping

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-61
02/29/12

Air Conditioner Package/Rooftop Units


Users Comment:
Ask maintenance personnel for comments on performance and condition of
package/rooftop unit before starting assessment.
In addition to gathering deficiency information for package/rooftop units, the
engineer/engineering technician will often gather information specific to the type of unit. The
inventory provides a single-source account of these major components within an airport. The
information inventoried should be:
Unit of Measurement (UOM): EA
Capacities to collect: TN, MBH
Additional attribute choices:
1. Package Cooling Type
2. Heating Type

Checks to be made:
1. Air conditioner package/rooftop units
Rust damage, oil/refrigerant leaks, excessive noise and vibration
Loose, missing, or damaged parts
Debris collected on intake side of condenser coils or fans bent or out of
balance.
Damaged or loose electrical connections
Type of refrigerant used in system
Aged, deteriorated, or inoperative package/rooftop unit

Cooling Towers
Users Comment:
Ask maintenance personnel for comments on performance and condition of cooling tower
before starting assessment.
In addition to gathering deficiency information for cooling towers, the engineer/engineering
technician will often gather information specific to the type of cooling tower. The inventory
provides a single-source account of these major components within an airport. The
information inventoried should be:
Unit of Measurement (UOM): EA
Capacities to collect: TN
Additional attribute choices:
1. Material
2. Cooling Tower Type
3. Chemical Treatment (Yes or No)
4. Absorption System (Yes or No)
Checks to be made:
1. Cooling towers
Rust damage, calcium build-up, water leaks, excessive noise and vibration
Loose, missing, or damaged parts
Condition of cold deck, drift eliminators, motors, drives, belts, blowers or fans
Damaged or loose electrical connections

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-62
02/29/12

Condition of tower supports


Aged, deteriorated, or inoperative cooling tower

Air Conditioner, Window


Users Comment:
Ask maintenance personnel for comments on performance and condition of air
conditioner before starting assessment.

Checks to be made:
1. Air conditioner, window
Rust damage, water leaks, excessive noise and vibration
Loose, missing, or damaged parts
Openings between air conditioner and window or wall
Aged, deteriorated, or inoperative air conditioner

Condenser, Evaporative
Users Comment:
Ask maintenance personnel for comments on performance and condition of evaporative
cooler before starting assessment.
In addition to gathering deficiency information for condensing units, the engineer/engineering
technician will often gather information specific to the type of unit. The inventory provides a
single-source account of these major components within an airport. The information
inventoried should be:
Unit of Measurement (UOM): EA
Capacities to collect: TN
Additional attribute choices:
1. Air-Cooled
2. Water-Cooled

Checks to be made:
1. Condenser, evaporative
Rust damage, calcium build-up, water leaks, excessive noise and vibration
Loose, missing, or damaged parts
Condition of pump, motor, belts, blowers or fans
Damaged or loose electrical connections
Condition of condenser supports
Aged, deteriorated, or inoperative evaporative condenser

Evaporative Coolers
Checks to be made:
1. Evaporative coolers
Rust damage, calcium build-up, water leaks, excessive noise and vibration
Loose, missing, or damaged parts
Leaks at pump or in piping
Improper setting of float control device

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-63
02/29/12

Improper overflow of solids contained in water


Insufficient outdoor air flow
Clogged nozzles
Inadequate spread of water
Aged, deteriorated, or inoperative evaporative cooler

Computer Room Units


Users Comment:
Ask maintenance personnel for comments on performance and condition of computer
room unit before starting assessment.

Checks to be made:
1. Computer room units
Rust damage, oil/refrigerant leaks, water leaks, excessive noise and vibration
Loose, missing, or damaged parts
Aged, deteriorated, high maintenance or inoperative computer room unit

Circulating Pumps
Checks to be made:
1. Circulating pumps
Rust damage, water leaks, excessive noise and vibration
Loose, missing, or damaged parts
Condition of motor, coupling, and pump
Damaged or missing pump insulation
Damaged or loose electrical connections
Aged, deteriorated, or inoperative pump

Fan Coil Units


Checks to be made:
1. Fan coil units
Rust damage, leaks, excessive noise and vibration
Loose, missing, or damaged parts
Aged, deteriorated, inoperative, or abandoned fan coil unit

Piping, Fittings, Valves


In addition to gathering deficiency information for valves, the engineer/engineering technician
will often gather information specific to the type of valve. The inventory provides a singlesource account of these major components within an airport. The information inventoried
should be:
Unit of Measurement (UOM): EA
Capacities to collect: IN
Additional attribute choices:
1. Type
2. Operating Mechanism
3. Material
2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-64
02/29/12

4. Rating
5. Connection Type
6. Location

Checks to be made:
1. Piping, fittings, valves
Condition of pipes, fittings, valves, hangers, or supports and pipe insulation
Aged or abandoned piping

Chemical Water Treatment System


Checks to be made:
1. Chemical water treatment system
Condition of controller, sensors, pumps, pipes, fittings and valves
Aged, deteriorated, inoperative, or abandoned water treatment system

D3040 Distribution Systems


Maintenance
Checks to be made:
1. Maintenance
Rust damage, air leaks
Loose, missing, or damaged parts, mounts, hangers, or fittings
Deteriorated surfaces, missing identifier, or blocked access

Ventilators
Checks to be made:
1. Ventilators
Rust damage, air leaks, loose, missing, or damaged parts, hangers, or
fittings.
Inoperative or missing ventilator.

Fans Supply/Exhaust
Checks to be made:
1. Fans supply/exhaust
Rust damage, air leaks, excessive noise and vibration
Loose, missing, or damaged parts
Condition of housing, motor, belt, and blower or fan
Damaged or loose electrical connections
Deteriorated, inoperative or abandoned fan unit

Air Handling Units


In addition to gathering deficiency information for air handling units, the engineer/engineering
technician will often gather information specific to the type of unit. The inventory provides a

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-65
02/29/12

single-source account of these major components within an airport. The information


inventoried should be:
Unit of Measurement (UOM): EA
Capacities to collect: CFM
Additional attribute choices:
1. Power Source
2. AHU Type
3. Cooling type
4. Heating type
5. Motor Size

Checks to be made:
1. Air handling units
Rust damage, water leaks, excessive noise and vibration
Loose, missing, or damaged parts
Condition of motor, belts and belt guard
Inoperative or disconnected dampers or damper motors
Inoperative or disconnected automatic filter system
Damaged or loose electrical connections
Aged, deteriorated, or inoperative air handling unit

Air Distribution
Users Comment:
Ask maintenance personnel for comments on performance and condition of air
distribution system before starting assessment. Are there even temperatures throughout
the areas?

Checks to be made:
1. Air distribution
Condition of ducts, supports, duct insulation, grilles and registers
Dirt, dust, and other deposits at the supply air grilles
Missing or damaged flexible duct connections or access panel covers

Piping, Fittings and Valves


In addition to gathering deficiency information for valves, the engineer/engineering technician
will often gather information specific to the type of valve. The inventory provides a singlesource account of these major components within an airport. The information inventoried
should be:
Unit of Measurement (UOM): EA
Capacities to collect: IN
Additional attribute choices:
1. Type
2. Operating Mechanism
3. Material
4. Rating
5. Connection Type

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-66
02/29/12

6. Location

Checks to be made:
1. Piping, fittings and valves
Condition of pipes, fittings, valves, hangers, supports, and pipe insulation
Aged or abandoned piping

D3050 Terminal & Package Units


Terminal & Package Units
In addition to gathering deficiency information for package/rooftop units, the
engineer/engineering technician will often gather information specific to the type of unit. The
inventory provides a single-source account of these major components within an airport. The
information inventoried should be:
Unit of Measurement (UOM): EA
Capacities to collect: TN, MBH
Additional attribute choices:
1. Package Cooling Type
2. Heating Type

Checks to be made:
1. Terminal & package units
Rust damage, steam or water leaks
Disconnected, missing, or damaged parts
Condition of insulation
Abandoned or inoperative heat exchanger/converter

D3060 Controls and Instrumentation


Users Comment:
Ask maintenance personnel for comments on performance and condition of control
system before starting assessment.

Checks to be made:
1. Controls and instrumentation
Abandoned, inoperative, loose, missing, or damaged parts or components
Aged, high maintenance, or obsolete control system

D3070 Systems Testing & Balancing


Humidifiers/Electronic Air Cleaners
Checks to be made:
1. Humidifiers/electronic air cleaners
Rust damage, loose, disconnected, missing, or damaged parts
Damaged or loose electrical connections
Deteriorated or inoperative humidifier/electronic air cleaner

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-67
02/29/12

Specialized Equipment
Specialized equipment includes laboratory fume hoods, air curtains, dust collectors, kitchen
hood systems, and engine exhaust systems.
Users Comment:
Ask maintenance personnel for comments on performance and condition of specialized
equipment before starting assessment.

Checks to be made:
1. Specialized equipment:
Rust damage, air leaks, excessive noise and vibration
Loose, missing, or damaged parts
Condition of housing, motor, belt, and blower or fan
Damaged or loose electrical connections
Deteriorated, inoperative or abandoned equipment

D3090 Other HVAC Systems and Equipment


This subsystem includes special mechanical systems that are not normally included as part
of standard HVAC systems.

D40 Fire Protection Systems


D4010 Sprinklers
Maintenance
In addition to gathering deficiency information for fire protection systems, the
engineer/engineering technician will often gather information specific to the type of system.
The inventory provides a single-source account of these major components within an airport.
The information inventoried should be:
Unit of Measurement (UOM): EA
Capacities to collect: SF (of coverage), IN (diameter of pipe)
Additional attribute choices:
1. Extinguisher Type
2. NFPA Classification

Checks to be made:
1. Maintenance
Rust damage, water leaks
Loose, missing, or damaged parts, hangers, or fittings
Continuous running or too-frequent cycling of jockey pump
Deteriorated surfaces, missing identifier, or blocked access

Sprinkler System Alarm Valves


Users Comment:
Ask maintenance personnel for comments on performance and condition of fire
protection system before starting assessment.

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-68
02/29/12

In addition to gathering deficiency information for valves, the engineer/engineering technician


will often gather information specific to the type of valve. The inventory provides a singlesource account of these major components within an airport. The information inventoried
should be:
Unit of Measurement (UOM): EA
Capacities to collect: IN
Additional attribute choices:
1. Type
2. Operating Mechanism
3. Material
4. Rating
5. Connection Type
6. Location

Checks to be made:
1. Sprinkler system alarm valves
Rust damage, air leaks, water leaks
Loose, disconnected, missing, or damaged parts
Damaged or loose electrical connections
Aged deteriorated or damaged alarm valve

Piping, Fittings, Valves


In addition to gathering deficiency information for valves, the engineer/engineering technician
will often gather information specific to the type of valve. The inventory provides a singlesource account of these major components within an airport. The information inventoried
should be:
Unit of Measurement (UOM): EA
Capacities to collect: IN
Additional attribute choices:
1. Type
2. Operating Mechanism
3. Material
4. Rating
5. Connection Type
6. Location

Checks to be made:
1. Piping, fittings, valves
Rust damage, water leaks, air leaks
Loose, missing, or damaged parts, mounts, hangers, or fittings
Condition of sprinkler heads
Verify that valves are locked in open position

Fire Protection Pumps


In addition to gathering deficiency information for pumps, the engineer/engineering technician
will often gather information specific to the type of pump. The inventory provides a single-

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-69
02/29/12

source account of these major components within an airport. The information inventoried
should be:
Unit of Measurement (UOM): EA
Capacities to collect: HP, GPM
Additional attribute choices:
1. Type
2. Material
3. Power/Fuel Source
4. Mounting Method

Checks to be made:
1. Water pumps
Rust damage, water leaks, excessive noise and vibration
Loose, missing, or damaged parts
Condition of motor, coupling, and pump
Damaged or missing pump insulation
Damaged or loose electrical connections
Aged, deteriorated, or inoperative pump

D4020 Standpipes
Piping, Fittings, Valves
In addition to gathering deficiency information for valves, the engineer/engineering technician
will often gather information specific to the type of valve. The inventory provides a singlesource account of these major components within an airport. The information inventoried
should be:
Unit of Measurement (UOM): EA
Capacities to collect: IN
Additional attribute choices:
1. Type
2. Operating Mechanism
3. Material
4. Rating
5. Connection Type
6. Location

Checks to be made:
1. Piping, fittings, valves
Rust damage, water leaks, air leak
Loose, missing, or damaged parts, mounts, hangers, or fittings
Condition of sprinkler heads
Verify that valves are locked in open position
2. Hoses
Rotted or damaged hose
Damaged connectors or fittings

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-70
02/29/12

D4030 Fire Protection Specialties


Fire Extinguishing Devices
Users Comment:
Ask maintenance personnel for comments on performance and condition of fire
protection system before starting assessment.

Checks to be made:
1. Fire extinguishing devices
Rust damage
Condition of nozzles
Loose, disconnected, missing, or damaged parts
Verify adequate charge and assessment information

D4090 Other Fire Protection Systems


Chemical Extinguishing Systems
Users Comment:
Ask maintenance personnel for comments on performance and condition of fire
protection system before starting assessment.

Checks to be made:
1. Chemical extinguishing systems
Rust damage
Condition of nozzles
Loose, disconnected, missing, or damaged parts
Damaged or loose electrical connections
Condition of chemical cylinder or tank and gas pressure level

Piping, Fittings, Valves


In addition to gathering deficiency information for valves, the engineer/engineering technician
will often gather information specific to the type of valve. The inventory provides a singlesource account of these major components within an airport. The information inventoried
should be:
Unit of Measurement (UOM): EA
Capacities to collect: IN
Additional attribute choices:
1. Type
2. Operating Mechanism
3. Material
4. Rating
5. Connection Type
6. Location

Checks to be made:
1. Piping, fittings, valves

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-71
02/29/12

Rust damage, water leaks, air leak


Loose, missing, or damaged parts, mounts, hangers, or fittings
Condition of sprinkler heads
Verify that valves are locked in open position

Air Compressors
Checks to be made:
1. Air compressors
Rust damage, air leak
Loose, missing, or damaged parts, mounting, hangers, or fittings
Continuous running or too-frequent cycling
Aged deteriorated or damaged air compressor

D50 Electrical
D5010 Electrical Service and Distribution
Maintenance
Checks to be made:
1. Cords, cord extensions, portable and appliance cords and plugs
Inadequate, unsafe, unreliable, incorrect types
Lengths too long, poor insulation, twisted, spliced, exposed to damage
underfoot, laying on floor or across heated surfaces or lamps; lamp types
used for portable extensions that are subject to moisture, oil, and grease
Plugs: cracks, breaks, loose connections, wires improperly attached and in
danger of pulling away from plug when removing from outlet, missing
protective cover on male ends, no grounding terminal or ground wire with
clamp
Power Plugs: cable clamps loose or missing
Improper or unauthorized flexible cords and cable running through holes in
walls, ceiling or floor

Distribution System (Interior) Switchgear


Electrical switchgear, associated apparatus, and equipment connected to distribution circuits
in buildings, 600 volts and under, and not located in vaults or fire resistant rooms. It includes,
primarily, switchgear known as "metal clad", "draw out", "cubicle", or "truck" type.

Checks to be made:
1. Housekeeping
Poor appearance, damp, dirty, inaccessible
Detrimental conditions (greater than 100, humidity, rodents/insects, stored
combustibles, trash/dirt/dust, poor location, poor ventilation, gas/steam/water
leakage)
2. Exterior housings and enclosure ground

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-72
02/29/12

Rust, corrosion, need for painting, signs of abuse, unauthorized or improper


signs, scribbling, calendars
Storage of materials or dust accumulations on top of enclosures
Missing parts, schedules, or other items
Poor condition and inadequacy of enclosure ground

3. Interior of compartments, cubicles, and drawers


Dirty, condensation
Symptoms of overheating, burns from ground and short circuits, defective
insulation
Defective operation of locks, doors, and drawers
4. Pneumatic systems
Poor general condition and unsatisfactory operation of all components
serving breakers including air pressure, valves, pistons, and associated
equipment
Poor speed of air-pressure recovery, air leaks, moisture and dirt in air lines
5. Enclosed switches
Unsatisfactory operation of handle and mechanism
Blade latch functions improperly
Blades insecure when closed
Blade, clips or tongue lack cleanliness, signs of oxidation, arcing,
overheating, and poor contact
6. Switchgear relays
Visible evidence of accumulations of dust and dirt, broken glass, loose or
missing nuts, loose mounting, noisy operation, signs of arcs, loose
connections
7. Instrument transformers
Lack of cleanliness, inadequate connections, inadequate insulation, improper
ventilation, and unsatisfactory grounding
8. Small wiring
Physical damage, defective insulation, poorly soldered connections, damage
to other connections
9. Buses and buswork
Lack of cleanliness, defective insulation, overheating, signs of flashovers
10. Rheostats/associated mechanisms
Inadequate operation, lack of cleanliness, overheating, dirty contacts, overtravel
11. Mechanical devices: de-energized
Unsatisfactory operation and inadequacy of mechanical devices for elevating
and lowering or drawing out switchgear
Improper operation of interlocks, gang switches, and contact safety shutters
12. Switchgear foundations

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-73
02/29/12

Settling or movement of floors, pedestals, and other foundations resulting in


possible misalignment of operating parts in switchgear

Boxes
Checks to be made:
1. Boxes
Loose mounting/attachment
Missing mounting hardware or fasteners
Loose or missing cover
Open conduit or cable entry knockouts
Corrosion with pitting or blistering
Corrosion with loss of base material
Evidence of overheating, grounds, and short circuits, overheated splices,
damaged or defective insulation
Other physical damage such as impact, breaks, or deformation
Missing identification markers such as labels or color indicators
Conduit connection separated or loose

Cable
Checks to be made:
1. Cable
Dirty, poor ventilation, presence of moisture, greases, oil, chemical fumes
Improper or unauthorized connections and dangerous temporary connections
Damaged wiring devices, defective insulators, cleats, and cable supports
Broken/missing parts or exposed live parts.
Excessive cable sag, crowded cable spacing, excessive number of
conductors in conduit and raceways
Evidence of overheating, grounds, and short circuits, overheated splices,
damaged or defective insulation
Need for painting of non-current-carrying parts subject to corrosion
Unsafe, unreliable cable and wire to lighting and power panels
Fuses, switches, and other sources of discontinuity in the neutral wire of
grounded AC systems

Circuit Breakers
Air and oil circuit breakers, oilless-type air blast breakers - de-energized, 50 Amperes and
above. Only conduct a visual assessment of fuses and small circuit breakers and their
enclosures in electrical circuits operating at 600 volts or below and rated at 30 amperes and
below.
DO NOT contact fuses. DO NOT remove covers. DO NOT de-energize.

Checks to be made:
1. Circuit breakers
Incorrect wipe of main and arcing contacts on opening and closing

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-74
02/29/12

Overheating, lack of continuity, and looseness of connections on all


mechanisms
Incorrectly placed pins and cotter pins
Improper functioning of rods and moving parts, binding occurs when
operating breaker
No freedom of action in tripping devices and latches
Insufficient travel of armature of over-current trip devices to assure release of
breaker latch
Dirty oil in oil-film timers
Improper functioning and unsatisfactory condition of control switch and
closing relay

2. Oil tanks
Leaks, cracks, corrosion, defective gaskets, improper oil levels, incorrect
gauge indications, presence of dirt in oil, or sludge
3. Bushings and insulators
Accumulation of dirt, cracks, chips, lack of rigidity of supports, inadequacy of
connections
4. Arc chutes
Moisture and other contaminants present, arc mufflers have loose scale,
runners and springs have wear or other damage
5. Indicating lamps
Inoperative

Conduit
Checks to be made:
1. Conduit
Loose or missing fasteners or fittings (such as straps, couplings, or
connectors) causing lack of support
Physical damage such as breaks or abnormal deformation or bends
Corrosion with loss of base metal
Evidence of overheating or burning such as charred, flash over, carbon
tracking, or other heat related deformation
Abandoned conduits with no identified or intended use

Fuses
Checks to be made:
1. By-passing
Apparent by-passing of fuses or circuit breakers report for further
investigation
2. Housekeeping
Dust, dirt, oil, grease, corrosion, foreign matter within enclosure
Inadequate identification of circuits

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-75
02/29/12

3. Enclosures
Deterioration of enclosures or connecting conduit or cable due to rust or
corrosion
Loose, corroded, or missing covers
4. Connections (if visible without removing covers)
Loose, corroded, inadequate
Deteriorated insulation
5. Fuses (if visible without removing covers)
Overheating, indicated by discoloration of brass or copper at contact points
Distortion, charring, deterioration of fiber cases of cartridge type cases
6. Grounding
Loose corroded connections; deteriorated or abraded insulation; frayed or
broken cables

Grounding
Checks to be made:
1. Instrumentation grounding system - grounding conductor insulation
Cut, broken, physical damage
2. Instrumentation grounding system - grounding rod
Bent, broken, or missing
3. Instrumentation grounding system - grounding conductor termination
Loose, corroded, cracked, missing, improper material (dislike or incompatible
metals)
Signs of arcing, carbon tracking, burning or overheating
4. Lightning protection - rods, points, air terminals
Bent, damaged, missing
5. Lightning protection - rod mounting bases
Improperly anchored to structure, damaged, cable connectors loose or
missing
6. Lightning protection - main conductor cable and downloads
Loose, missing, broken, signs of burning, corrosion, frayed cable strands, not
anchored to structure
7. Lightning protection - ground rod
Download connection loose, damaged, or disconnected

Overhead Services
Checks to be made:
1. Overhead services

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-76
02/29/12

Aerial drop cable: too tight (no sag) causing excessive force/pressure on the
mast; too much sag; less than 10 above highest point of grade; less than 2
away from surrounding surfaces or appurtenances (such as roof surfaces,
windows, doors, walls, columns, or trees and other buildings); rubbing
against surrounding surfaces or appurtenances.
Cable insulation: frayed, cracked, cut, burned, show signs of overheating, or
missing
Cable to cable connections: missing, loose, show signs of overheating, or
have no insulation or are missing the drip loop
Cable to mast connections and fasteners: missing, loose, corroded with loss
of base metal, use improper material, or is made less that 2 away from
surrounding surfaces or appurtenances
Mast conduit: less than 2 in diameter; not rigid galvanized steel; shows signs
of physical damage (such as bent or broken); fasteners missing, loose,
improper material type, or corroded with loss of base metal; roof seal and
flashing missing where the mast conduit penetrates a roof; connections
loose, missing, corroded with loss of base metal, or show signs of burning or
overheating
Mast conduit head: loose, missing, broken, corroded with loss of base metal,
shows signs of burning or overheating; installed less than 2 away from
surrounding surfaces or appurtenances; missing internal parts such as
insulation and fasteners

Panelboards
Checks to be made:
1. Panelboards
Dirty, corroded, signs of overheating, need for touch-up painting
Un-posted or illegible instructions, identification charts, circuit diagrams, and
feeder schedules

Safety Switches
Checks to be made:
1. Safety switches
Dirty, corroded, signs of overheating, need for touch-up painting
Un-posted or illegible instructions, identification charts, circuit diagrams, and
feeder schedules
Loose or inadequate connections
Switches need lubrication, operate improperly
Knife switches and fuse clips improperly aligned
Improper fuse ratings and ground connections
Removed fuse jumpers and dangerous temporary connections

Switchboards
Electrical switchgear, associated apparatus, and equipment connected to distribution circuits
in buildings, 600 volts and under, and not located in vaults or fire resistant rooms. It includes,
primarily, switchgear known as "metal clad", "draw out", "cubicle", or "truck" type.

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-77
02/29/12

Checks to be made:
1. Housekeeping
Poor appearance, damp, dirty, inaccessible
Detrimental conditions (greater than 100, humidity, rodents/insects, stored
combustibles, trash/dirt/dust, poor location, poor ventilation, gas/steam/water
leakage)
2. Exterior housings and enclosure ground
Rust, corrosion, need for painting, signs of abuse, unauthorized or improper
signs, scribbling, calendars
Storage of materials or dust accumulations on top of enclosures
Missing parts, schedules, or other items
Poor condition and inadequacy of enclosure ground
3. Interior of compartments, cubicles, and drawers
Dirty, condensation
Symptoms of overheating, burns from ground and short circuits, defective
insulation
Defective operation of locks, doors, and drawers
4. Pneumatic systems
Poor general condition and unsatisfactory operation of all components
serving breakers including air pressure, valves, pistons, and associated
equipment
Poor speed of air-pressure recovery, air leaks, moisture and dirt in air lines
5. Enclosed switches
Unsatisfactory operation of handle and mechanism
Blade latch functions improperly
Blades insecure when closed
Blade, clips or tongue lack cleanliness, signs of oxidation, arcing,
overheating, and poor contact
6. Switchgear relays
Visible evidence of accumulations of dust and dirt, broken glass, loose or
missing nuts, loose mounting, noisy operation, signs of arcs, loose
connections
7. Instrument transformers
Lack of cleanliness, inadequate connections, inadequate insulation, improper
ventilation, and unsatisfactory grounding
8. Small wiring
Physical damage, defective insulation, poorly soldered connections, damage
to other connections
9. Buses and buswork
Lack of cleanliness, defective insulation, overheating, signs of flashovers
10. Rheostats/associated mechanisms

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-78
02/29/12

Inadequate operation, lack of cleanliness, overheating, dirty contacts, overtravel

11. Mechanical devices: de-energized


Unsatisfactory operation and inadequacy of mechanical devices for elevating
and lowering or drawing out switchgear
Improper operation of interlocks, gang switches, and contact safety shutters
12. Switchgear foundations
Settling or movement of floors, pedestals, and other foundations resulting in
possible misalignment of operating parts in switchgear
Dirty, corroded, signs of overheating, and need for touch-up painting
Un-posted or illegible instructions, identification charts, circuit diagrams, and
feeder schedules
Loose or inadequate connections
Switches need lubrication, operate improperly
Knife switches and fuse clips improperly aligned
Improper fuse ratings and ground connections
Removed fuse jumpers and dangerous temporary connections

Transformers
Checks to be made:
1. Dry-type transformers
Accumulation of dust on core, coils, and leads
Evidence of moisture, oil, or other contaminants
Evidence of overloads and burned insulation
Poor contacts and connections
Signs of corrosion
Poorly painted surfaces, nameplates, guards and warning signs
Inadequate ventilation, detrimental ambient temperatures, and defective
ground connections
Check operating temperature loads and voltage during critical operating
periods from log data (if available)

Transformers Energized
Energized electric distribution transformers used for voltage reduction.

Checks to be made:
1. Concrete foundations and supporting pads
Settling and movement, surface cracks exceeding 1/16 inch in width,
breaking or crumbling within 2 inches of anchor bolts
Anchor bolts: loose or missing parts, corrosion, particularly at points closest
to metal base plates and concrete foundation resulting from moisture or
foreign matter, and exceeding 1/8 inch in depth
2. Mounting platforms wooden
Cracks, breaks, signs of weakening around supporting members

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-79
02/29/12

Rot, particularly at bolts and other fastening, holes through which bolts pass,
wood contacting metal
Charring and burning at contact points, indicating grounding deficiency
Inadequate wood preservation treatment

3. Mounting platforms metallic


Deep pits from rust, corrosion, or other signs of deterioration likely to weaken
structure
4. Hangers/brackets/braces/connectors
Rust, corrosion, bent, distorted, loose, missing, broken, split, other damage
Burning or charring at wood contact points resulting from grounding
deficiency
5. Enclosures, cases, and attached appurtenances
Collections of dirt or other debris close to enclosure that may interfere with
radiation of heat from transformer or flashover
Dirt, particularly around insulators, bushings, or cable entrance boxes
Leaks of liquid-filled transformers
Deteriorated paint, scaling, rust
Corrosion, particularly at all attached appurtenances, such as lifting lugs,
bracket connections, and metallic parts in contact with each other
6. Nameplates and warning signs
Dirty, chipped, worn, corroded, illegible, improperly placed
7. Grounding
Visual connections: loose, missing, broken connections; signs of burning or
overheating, corrosion, rust, frayed cable strands, more than 1 strand broken
in 7-strand cable, more than 3 strands broken in 19-strand cable
8. Bushings and insulators
Cracked, chipped, or broken porcelain
Indication of carbon deposits
Streaks from flashovers
Dirt, dust, grease, soot, or other foreign material on porcelain parts
Signs of oil or moisture at point of insulator entrance
9. Grounding and phase terminals
Overheating evidenced by excessive discoloration of copper
Loose connection bolts
Defective cable insulation
No mechanical tension during temperature changes
Leads appear improperly trained and create danger of flashovers from
unsafe phase-to-phase or phase-to-ground clearances caused by
deterioration of leads or expansions during temperature changes
10. Breathers
Holes plugged with debris
Desiccant-type breathers need servicing or replacement

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-80
02/29/12

11. Grills and louvers for ventilation of air-cooled transformers


Plugged with debris or foreign matter, interfering with free passage of air
(openings located near floor or ground line can be inspected with small
nonmetallic framed mirror having long insulated handle, used in conjunction
with light from hand flash lamp having insulated casing; throw light beam
onto mirror and reflect upward into openings)

Transformers De-energized
De-energized electric distribution transformers used for voltage reduction.
Transformer must be de-energized and circuit switches locked out. Use grounding harnesses
on input terminals.

Checks to be made:
1. Bushings and insulators
Insulators and porcelain parts: indications of cracks, checks, chips breaks;
where flashover streaks are visible, reexamine for injury to glaze or for
presence of cracks
Chipped glaze exceeding 1/2 inch in depth or an area exceeding one square
inch on any insulator or insulator unit (report for investigation by a qualified
electrical engineer)
Severe cracks, chipped cement, or indications of leakage around bases of
joints of metal to porcelain parts at terminal and transformer ends
Terminal ends: mechanical deficiencies, looseness, corrosion, damage to
cable clamps
Improper oil level in oil-filled bushings
Heating evidenced by discoloration, and corrosion indicated by blue, green,
white, or brown corrosion products on metallic portions of all main and
ground terminals, including terminal board and grounding connections inside
transformer case
2. Coils and cores
Deficiencies, dirt, and sludge exceeding inch (when cover is open,
examine interior; if feasible, probe down sides with glass rod)
3. Enclosures and cases
If case is opened for any reason, examine for signs of moisture inside cover,
and where present for plugged breathers, inactive desiccant, enclosure
leakage, etc.
4. Gauges and alarms
Liquid level gauge and alarm system: dirty, not legible, improper frequency of
calibration

Service & Distribution


Use this section to determine the need to replace the entire Service & Distribution System as
a whole, versus the repair or replacement of certain or specific system components. In
general, the Service & Distribution systems consist of the service transformer(s). The
overhead or lateral service feeders, the main switchgear or main distribution panelboard(s).
The system also includes any subfeeders from the switchgear or main distribution panelboard

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-81
02/29/12

to step down transformers or other panelboards and the sub-fed equipment, such as the step
down transformers and other panelboards. Additional components of the Service &
Distribution system include Motor Control Centers.
CONSIDERATIONS: Make the decision to replace the entire Service & Distribution system
only after evaluating and determining the condition of the systems inherent components and
equipment. Thus, make the decision to replace the entire system only by weighing the
overall findings of the inherent components conditions.

Checks to be made:
1. Service & distribution
System equipment and components: reliability and availability of spare parts,
layout and modernization, maintainability
Cost to replace entire system versus cost to replace/repair individual
components or equipment
Overall physical condition of individual components or equipment and
maintenance history
Overall age of the components and equipment
Overall capacity of the system and determination of overloading or available
capacity for expansion

Wireways
Checks to be made:
1. Wireways
Dirty, poor ventilation, detrimental ambient conditions, presence of moisture,
greases, oil, chemical fumes
Improper or unauthorized connections and dangerous temporary connections
Damaged wiring devices, defective insulators, cleats, and cable supports
Broken or missing parts or exposed live parts
Excessive cable sag and vibration, crowded cable spacing, excessive
number of conductors in conduit and raceways
Evidence of overheating, grounds, and short circuits, overheated splices,
damaged or defective insulation
Need for painting of non-current-carrying parts subject to corrosion
Loose mounting/attachment
Missing mounting hardware or fasteners
Loose cover
Missing cover
Open conduit or cable entry knockouts
Corrosion with pitting or blistering
Corrosion with loss of base material
Evidence of overheating, grounds, and short circuits, overheated splices,
damaged or defective insulation
Other physical damage such as impact, breaks, or deformation
Missing identification markers such as labels or color indicators
Conduit connection separated or loose

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-82
02/29/12

Motor Starters/Motor Control Center


Checks to be made:
1. Motor starters/motor control center
Dirty, corroded, signs of overheating
Missing or illegible instructions, identification charts, circuit diagrams, and
feeder schedules
Loose or inadequate connections
Switches need lubrication, operate improperly
Knife switches and fuse clips improperly aligned
Improper fuse ratings and ground connections
Removed fuse jumpers and dangerous temporary connections
Cut, broken, or damaged grounding conductor insulation
Grounding conductor termination is loose, corroded, cracked, missing,
improper material (dislike or incompatible metals)
Signs of arcing, carbon tracking, burning or overheating
Instrumentation indicators such as lights or gauges broken or inoperative
Interior not clean or moisture free
Enclosure damaged and cannot be sealed, openings are unused exposing
interior live surfaces or connections

D5020 Lighting & Branch Wiring


Maintenance
Checks to be made:
1. Switches and breakers
Poor condition of contacts, contact misalignment
Signs of overheating, oxidation, and inadequate capacity
Rust, corrosion, loose brackets on group operated switches
2. Receptacles and other devices
Defective operation, broken or missing parts, arcing noises
Insecure, loose, damaged, missing plate or switch cover
Not grounded
Excessive use of extension cords
3. Lighting fixtures
Broken or missing parts such as diffusers, enclosures, or covers
Loose or missing mounting hardware and fasteners
Inoperative
Loud humming of ballast
Evidence of burning or overheating, such as carbon tracking, flash over, or
deformation

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-83
02/29/12

Devices
Checks to be made:
1. Receptacles
Dirty, inadequate, defective contacts, difficult plugging, overheating, evidence
of overloading on multiple sockets, servicing lamps or appliances, lack of
grounding terminal
Inadequate number, improper type, inconvenient location, loose or damaged
plate covers
Receptacles without GFCI (Ground Fault Circuit Interrupt) protection in
dwelling unit kitchens and bathroom
Outdoor receptacles not weatherproof

Lighting Fixtures and Components


Interior emergency building lighting, including exit lighting, wall mounted lights and wall
hanging battery pack emergency lighting located in auditorium, corridors, lobbies,
passageways, stairways, and fire escapes.

Checks to be made:
1. Lighting Fixtures
Inadequately supported, insecure, and improperly located
Evidence of unauthorized removal and relocation
Incorrect types installed in hazardous locations; change in facility class
requires replacement
Improperly located in clothes closets (should be above door or in ceiling and
not serviced with cord pendants)
Cracked or broken luminaries and fixture parts, missing pull cords, metal pull
chains not provided with insulating links
Indications of objects being supported from, hung on, or stored in fixtures
Evidence of overheating, undersized, or other damage to sockets
Exposed or damaged connecting wiring
2. Lamps
Oversized, blistering, loose base
Thermal cracks from contact with fixture
Bare lamps in hazardous locations
Poor socket lamp connections and proper types for special applications
Operation of fluorescent fixtures shows poor burning and starting
characteristics, and loud humming ballasts
3. Lighting voltage
Unauthorized connections of hot plates, coffee pots, heating devices and
other electrical equipment on lighting circuits
Interference with branch circuits for power and lighting from motor starting or
stopping (such as excessive light flicker or excessive voltage dips causing
fluorescent/mercury lamps to drop out)
4. Illumination levels
Ambient conditions such as dirty walls and ceilings

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-84
02/29/12

D5030 Communications & Security


Maintenance
Checks to be made:
1. Connections and termination (visual)
Poor condition of contacts, contact misalignment
Signs of overheating, oxidation, and inadequate capacity
Rust, corrosion, loose brackets on group operated switches
2. Control stations and other devices
Visual signs of defective operation, broken or missing parts, arcing noises
Insecure, loose, damaged, missing plate or switch cover
Not grounded
3. Enclosures and cabinets
Broken or missing parts
Loose mounting fasteners
Corrosion
Physical damage prohibiting normal function
Missing identification tags
Missing or outdated maintenance logs

Fire Alarm Systems


In addition to gathering deficiency information for fire alarm systems, the
engineer/engineering technician will often gather information specific to the type of system.
The inventory provides a single-source account of these major components within an airport.
The information inventoried should be:
Unit of Measurement (UOM): EA
Capacities to collect: SF (of coverage)
Additional attribute choices:
1. Panel Type

Checks to be made:
1. Alarm systems fire/theft
Wire terminal connections in panel and pull-boxes: tightness or possible
corrosion
Pull-boxes and mechanisms: proper lubrication
Improper operation or improper signals transmitted over fire alarm system
(actuate interior heat or smoke detector system by applying heat to a
selected heat/smoke detector in the building; verify proper operation with the
Fire Department's operator)
Improper operation of individual heat/smoke detectors (for systems not
connected to local fire alarm system)
Improper automatic sprinkler system fire department connections
2. Termination board, cabinet, pedestal or outlet
Missing identification or wiring diagram
2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-85
02/29/12

Loose or missing fasteners and supports


Missing parts
Physical damage such as broken or cracked termination strips, enclosure
covers, or cut wiring or cable
Abandoned wiring or cable
Presence of moisture of corrosion inside the equipment

3. Boxes
Loose mounting/attachment
Missing mounting hardware or fasteners
Loose or missing cover
Open conduit or cable entry knockouts
Corrosion with pitting or blistering
Corrosion with loss of base material
Evidence of overheating, grounds, and short circuits, overheated splices,
damaged or defective insulation
Other physical damage such as impact, breaks, or deformation
Missing identification markers such as labels or color indicators
Conduit connection separated or loose
4. Cable
Dirty, poor ventilation, detrimental ambient conditions, presence of moisture,
greases, oil, chemical fumes
Improper or unauthorized connections and dangerous temporary connections
Damaged wiring devices, defective insulators, cleats, and cable supports
Broken or missing parts or exposed live parts
Excessive cable sag and vibration, crowded cable spacing, excessive
number of conductors in conduit and raceways
Evidence of overheating, grounds, and short circuits, overheated splices,
damaged or defective insulation
Need for painting of non-current-carrying parts subject to corrosion
Unsafe, unreliable cable and wire to lighting and power panels
Fuses, switches, and other sources of discontinuity in the neutral wire of
grounded AC systems
Circuits: improper operation of switches, receptacles, wiring for overloaded
circuits and missing cover plates
5. Conduit
Loose or missing fasteners or fittings such as, straps, couplings, or
connectors causing lack of support
Physical damage such as breaks or abnormal deformation or bends
Corrosion with loss of base metal
Evidence of overheating or burning (such as charring, flash over, carbon
tracking, or other heat related deformation)
Abandoned conduits with no identified or intended use
Open conduit penetrations of fire barrier walls or floors

Intercom Systems
In addition to gathering deficiency information for intercom systems, the engineer/engineering
technician will often gather information specific to the type of system. The inventory provides

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-86
02/29/12

a single-source account of these major components within an airport. The information


inventoried should be:
Unit of Measurement (UOM): EA
Capacities to collect: SF (of coverage)
Additional attribute choices:
1. Panel Type

Checks to be made:
1. Intercom systems
Inoperative or damaged master, zone, or point station
Missing parts on master, zone, or point station such as control buttons, dials,
gauges, indicator lights, speakers, enclosure covers
Loose or missing fasteners for enclosures, wires, conduits or cabling
Missing speakers and point stations
Missing identification, wiring diagrams and specification information
Overall general housekeeping of the equipment for maintenance and upkeep
Type, size and capacity of the system, including capacity, number of stations
and wiring configuration
2. Termination board, cabinet, pedestal or outlet
Missing identification or wiring diagram
Loose or missing fasteners and supports, missing parts
Physical damage such broken or cracked termination strips, enclosure
covers, or cut wiring or cable
Abandoned wiring or cable
Presence of moisture or corrosion inside the equipment
3. Boxes
Loose mounting/attachment
Missing mounting hardware or fasteners
Loose or missing cover
Open conduit or cable entry knockouts
Corrosion with pitting or blistering
Corrosion with loss of base material
Evidence of overheating, grounds, and short circuits, overheated splices,
damaged or defective insulation
Other physical damage such as impact, breaks, or deformation
Missing identification markers such as labels or color indicators
Conduit connection separated or loose
4. Cable
Dirty, poor ventilation, detrimental ambient conditions, presence of moisture,
greases, oil, chemical fumes
Improper or unauthorized connections and dangerous temporary connections
Damaged wiring devices, defective insulators, cleats, and cable supports
Broken or missing parts or exposed live parts
Excessive cable sag and vibration, crowded cable spacing, excessive
number of conductors in conduit and raceways

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-87
02/29/12

Evidence of overheating, grounds, and short circuits, overheated splices,


damaged or defective insulation
Need for painting of non-current-carrying parts subject to corrosion
Unsafe, unreliable cable and wire to lighting and power panels
Fuses, switches, and other sources of discontinuity in the neutral wire of
grounded AC systems
Circuits for operation of switches, receptacles, wiring for overloaded circuits
and missing cover plates

5. Conduit
Loose or missing fasteners or fittings such as, straps, couplings, or
connectors causing lack of support
Physical damage such as breaks or abnormal deformation or bends
Corrosion with loss of base metal
Evidence of overheating or burning (such as charring, flash over, carbon
tracking, or other heat related deformation)
Abandoned conduits with no identified or intended use
Open conduit penetrations of fire barrier walls or floors

Telephone Systems
Checks to be made:
1. Telephone systems
Determine if the point of entry is underground or overhead
Determine number of terminal boards, cabinets, pedestals and outlets are
served by the system
2. For overhead service entry
Aerial drop cable: too tight (no sag) causing excessive force/pressure on the
mast; too much sag; less than 10 above highest point of grade; less than 2
away from surrounding surfaces or appurtenances (such as roof surfaces,
windows, doors, walls, columns, or trees and other buildings); rubbing
against surrounding surfaces or appurtenances
Cable insulation: frayed, cracked, cut, burned, show signs of overheating, or
missing
Cable to cable connections: missing, loose, show signs of overheating, have
no insulation, or missing the drip loop
Cable to mast connections and fasteners: missing, loose, corroded with loss
of base metal, use improper material, or made less than 2 away from
surrounding surfaces or appurtenances
Mast conduit: less than 2 in diameter; not rigid galvanized steel; shows signs
of physical damage (such as bent or broken); fasteners missing, loose,
improper material type, or are corroded with loss of base metal; roof seal and
flashing missing where the mast conduit penetrates a roof; mast conduit
connections loose, missing, corroded with loss of base metal, or show signs
of burning or overheating
Mast conduit head: loose, missing, broken, corroded with loss of base metal;
shows signs of burning or overheating; installed less than 2 away from
surrounding surfaces or appurtenances; missing internal parts such as
insulation and fasteners

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-88
02/29/12

3. For underground service entry


Cable riser: missing physical protection between grade and termination
board
Loose or missing cable or conduit fasteners between grade and termination
point
Physical damage such as fraying, cut, burned, or broken cable
4. Termination board, cabinet, pedestal or outlet
Missing identification or wiring diagram
Loose or missing fasteners and supports, missing parts
Physical damage such broken or cracked termination strips, enclosure
covers, or cut wiring or cable
Abandoned wiring or cable
Presence of moisture or corrosion inside the equipment
5. Boxes
Loose mounting/attachment
Missing mounting hardware or fasteners
Loose or missing cover
Open conduit or cable entry knockouts
Corrosion with pitting or blistering
Corrosion with loss of base material
Evidence of overheating, grounds, and short circuits, overheated splices,
damaged or defective insulation
Other physical damage such as impact, breaks, or deformation
Missing identification markers such as labels or color indicators
Conduit connection separated or loose
6. Cable
Dirty, poor ventilation, detrimental ambient conditions, presence of moisture,
greases, oil, chemical fumes.
Improper or unauthorized connections and dangerous temporary connections
Damaged wiring devices, defective insulators, cleats, and cable supports
Broken or missing parts or exposed live parts
Excessive cable sag and vibration, crowded cable spacing, excessive
number of conductors in conduit and raceways
Evidence of overheating, grounds, and short circuits, overheated splices,
damaged or defective insulation
Need for painting of non-current-carrying parts subject to corrosion
Unsafe, unreliable cable and wire to lighting and power panels
Fuses, switches, and other sources of discontinuity in the neutral wire of
grounded AC systems
Circuits: improper operation of switches, receptacles, wiring for overloaded
circuits and missing cover plates
7. Conduit
Loose or missing fasteners or fittings such as, straps, couplings, or
connectors causing lack of support
Physical damage such as breaks or abnormal deformation or bends

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-89
02/29/12

Corrosion with loss of base metal


Evidence of overheating or burning (such as charring, flash over, carbon
tracking, or other heat related deformation)
Abandoned conduits with no identified or intended use
Open conduit penetrations of fire barrier walls or floors

Television Systems
Checks to be made:
1. Television systems
Determine if the point of entry is underground or overhead
Determine number of terminal boards, cabinets, pedestals and outlets served
by the system
2. For overhead service entry
Aerial drop cable: too tight (no sag) causing excessive force/pressure on the
mast; too much sag; less than 10 above highest point of grade; less than 2
away from surrounding surfaces or appurtenances (such as roof surfaces,
windows, doors, walls, columns, or trees and other buildings); rubbing
against surrounding surfaces or appurtenances
Cable insulation: frayed, cracked, cut, burned, show signs of overheating, or
missing
Cable to cable connections: missing, loose, show signs of overheating, have
no insulation, or missing the drip loop
Cable to mast connections and fasteners: missing, loose, corroded with loss
of base metal, use improper material, or made less than 2 away from
surrounding surfaces or appurtenances
Mast conduit: less than 2 in diameter; not rigid galvanized steel; shows signs
of physical damage (such as bent or broken); fasteners missing, loose,
improper material type, or are corroded with loss of base metal; roof seal and
flashing missing where the mast conduit penetrates a roof; mast conduit
connections loose, missing, corroded with loss of base metal, or show signs
of burning or overheating
Mast conduit head: loose, missing, broken, corroded with loss of base metal;
shows signs of burning or overheating; installed less than 2 away from
surrounding surfaces or appurtenances; missing internal parts such as
insulation and fasteners
3. For Underground Service Entry
Cable riser: missing physical protection between grade and termination
board
Loose or missing cable or conduit fasteners between grade and termination
point
Physical damage such as fraying, cut, burned, or broken cable
4. Termination board, cabinet, pedestal or outlet
Missing identification or wiring diagram
Loose or missing fasteners and supports, missing parts
Physical damage such broken or cracked termination strips, enclosure
covers, or cut wiring or cable

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-90
02/29/12

Abandoned wiring or cable


Presence of moisture or corrosion inside the equipment

5. Boxes
Loose mounting/attachment
Missing mounting hardware or fasteners
Loose or missing cover
Open conduit or cable entry knockouts
Corrosion with pitting or blistering
Corrosion with loss of base material
Evidence of overheating, grounds, and short circuits, overheated splices,
damaged or defective insulation
Other physical damage such as impact, breaks, or deformation
Missing identification markers such as labels or color indicators
Conduit connection separated or loose
6. Cable
Dirty, poor ventilation, detrimental ambient conditions, presence of moisture,
greases, oil, chemical fumes
Improper or unauthorized connections and dangerous temporary connections
Damaged wiring devices, defective insulators, cleats, and cable supports
Broken or missing parts or exposed live parts
Excessive cable sag and vibration, crowded cable spacing, excessive
number of conductors in conduit and raceways
Evidence of overheating, grounds, and short circuits, overheated splices,
damaged or defective insulation
Need for painting of non-current-carrying parts subject to corrosion
Unsafe, unreliable cable and wire to lighting and power panels
Fuses, switches, and other sources of discontinuity in the neutral wire of
grounded AC systems
Circuits for operation of switches, receptacles, wiring for overloaded circuits
and missing cover plates
7. Conduit
Loose or missing fasteners or fittings such as, straps, couplings, or
connectors causing lack of support
Physical damage such as breaks or abnormal deformation or bends
Corrosion with loss of base metal
Evidence of overheating or burning (such as charring, flash over, carbon
tracking, or other heat related deformation)
Abandoned conduits with no identified or intended use
Open conduit penetrations of fire barrier walls or floors

Computer/LAN Systems
Checks to be made:
1. Termination board, cabinet, pedestal or outlet
Missing identification or wiring diagram
Loose or missing fasteners and supports, missing parts

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-91
02/29/12

Physical damage such broken or cracked termination strips, enclosure


covers, or cut wiring or cable
Abandoned wiring or cable
Presence of moisture or corrosion inside the equipment

2. Boxes
Loose mounting/attachment
Missing mounting hardware or fasteners
Loose or missing cover
Open conduit or cable entry knockouts
Corrosion with pitting or blistering
Corrosion with loss of base material
Evidence of overheating, grounds, and short circuits, overheated splices,
damaged or defective insulation
Other physical damage such as impact, breaks, or deformation
Missing identification markers such as labels or color indicators
Conduit connection separated or loose
3. Cable
Dirty, poor ventilation, detrimental ambient conditions, presence of moisture,
greases, oil, chemical fumes
Improper or unauthorized connections and dangerous temporary connections
Damaged wiring devices, defective insulators, cleats, and cable supports
Broken or missing parts or exposed live parts
Excessive cable sag and vibration, crowded cable spacing, excessive
number of conductors in conduit and raceways
Evidence of overheating, grounds, and short circuits, overheated splices,
damaged or defective insulation
Need for painting of non-current-carrying parts subject to corrosion
Unsafe, unreliable cable and wire to lighting and power panels
Fuses, switches, and other sources of discontinuity in the neutral wire of
grounded AC systems
Circuits for operation of switches, receptacles, wiring for overloaded circuits
and missing cover plates
4. Conduit
Loose or missing fasteners or fittings such as, straps, couplings, or
connectors causing lack of support
Physical damage such as breaks or abnormal deformation or bends
Corrosion with loss of base metal
Evidence of overheating or burning (such as charring, flash over, carbon
tracking, or other heat related deformation)
Abandoned conduits with no identified or intended use
Open conduit penetrations of fire barrier walls or floors

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-92
02/29/12

D5090 Other Electrical Systems


Maintenance
Checks to be made:
1. Connections and termination (visual)
Poor condition of contacts, contact misalignment
Signs of overheating, oxidation, or inadequate capacity
Rust, corrosion, or loose brackets on group operated switches
2. Control stations and other devices
Visual signs of defective operation, broken or missing parts, arcing noises
Insecure, loose, damaged, missing plate or switch cover
Not grounded
3. Enclosures and cabinets
Broken or missing parts
Loose mounting fasteners
Corrosion
Physical damage prohibiting normal function
Missing identification tags
Missing or outdated maintenance logs

Generator Sets
In addition to gathering deficiency information for generators, the engineer/engineering
technician will often gather information specific to the type of generator. The inventory
provides a single-source account of these major components within an airport. The
information inventoried should be:
Unit of Measurement (UOM): EA
Capacities to collect: KW
Additional attribute choices:
1. Voltage
2. Phase
3. Fuel
4. Performance Factor

Checks to be made:
1. Generator sets (visual unit not running)
Corrosion evidenced by pitting or blistering
Corrosion with loss of base metal
Panel fasteners loose, broken or missing
Unit not grounded
Indicator or gauges broken or inoperative
Fuel or coolant leaks
Damaged or missing battery
Missing parts or components
Missing identification, wiring diagram, specification tags

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-93
02/29/12

Loose, missing, corroded, or damaged conduit or cable connections


Broken or disconnected fuel lines
Unit mounting loose, broken or missing
Dirty or clogged radiator
Worn or loose belts
Recurring problems and testing frequency shown in maintenance records
and test logs
Overall general housekeeping, maintenance, and upkeep of equipment
Evidence of overheating or carbon tracking
Type and size of the generator including capacity, fuel type, voltage, phase
and power factor
Estimated connected load and comparison to unit specifications

Automatic Transfer Switch


Checks to be made:
1. Automatic transfer switch
Corrosion evidenced by pitting or blistering
Corrosion with loss of base metal
Enclosure mounting loose or broken
Panel fastener loose, broken or missing
Indicators or gauges damaged or inoperative
Enclosure damaged and cannot be sealed or closed
Unused opening not sealed
Handle bent or inoperative
Security devices missing or inoperative
Carbon tracking from flash over
Discoloration or deformity from overheating
Unit is not grounded
Switch or push buttons missing or damaged
Missing identification, wiring diagrams or operation instruction
Free space and clearance around the switch from debris or stored material
Overall housekeeping and maintenance of equipment

Equipment and Furnishings

Life-Cycle Estimates:
INSTITUTIONAL EQUIPMENT
Item:

Years

Item:

Years

REMOTE CONDENSER UNIT

15

CONDENSER/EVAPORATIVE
FAN MOTOR

10

EVAPORATIVE UNIT

15

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-94
02/29/12

E10 Equipment
E1010 Commercial Equipment
Laundry Equipment
Users Comment:
Ask maintenance personnel for comments on performance and condition of laundry
equipment before starting assessment.

Checks to be made:
1. Laundry equipment
Rust damage, oil leaks, steam leaks, water leaks, excessive noise and
vibration
Loose, missing, or damaged parts or components
Condition of equipment cabinet, doors, door glass, gaskets and hardware
Condition of motors and fans
Damaged or loose electrical controls or connections
Aged, deteriorated, or inoperative equipment

E1020 Institutional Equipment


Refrigeration Equipment
Users Comment:
Ask maintenance personnel for comments on performance and condition of refrigeration
equipment before starting assessment.

Checks to be made:
1. Refrigeration equipment
Rust damage, oil/refrigerant leaks, water leaks, excessive noise and vibration
Loose, missing, or damaged parts or components
Condition of equipment cabinet, doors, gaskets and hardware
Debris collected on intake side of condenser coils
Condition of refrigeration unit, motors and fans
Damaged or loose electrical controls or connections
Damaged refrigerant piping or missing pipe insulation
Type of refrigerant used in system
Aged, deteriorated, or inoperative equipment

E1030 Vehicular Equipment


The assessment of vehicular equipment is outside the scope of this document.

E1040 Other Equipment


Kitchen Equipment
Users Comment:
Ask maintenance personnel for comments on performance and condition of kitchen
equipment before starting assessment.

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-95
02/29/12

In addition to gathering deficiency information for kitchen equipment, the


engineer/engineering technician will often gather information specific to the type of
equipment. The inventory provides a single-source account of these major components
within an airport. The information inventoried should be:
Unit of Measurement (UOM): EA
Additional attribute choices:
1. Equipment Type

Checks to be made:
1. Kitchen equipment
Rust damage, refrigerant leaks, oil leaks, steam leaks, water leaks,
excessive noise and vibration
Loose, missing, or damaged parts or components
Condition of equipment cabinet, doors, door glass, gaskets and hardware
Grease and food particle build-up on equipment
Debris collected on intake side of condenser coils
Condition of refrigeration unit, motors and fans
Damaged or loose electrical controls or connections
Type of refrigerant used in system
Aged, deteriorated, or inoperative equipment

E20 Furnishings
E2010 Fixed Furnishings
Seating
Checks to be made:
1. Wood
Missing, cracked, warped, damaged/missing hardware, worn finish, worn/torn
fabric/cushions
2. Metal
Missing, bent, damaged/missing hardware, worn finish, worn/torn
fabric/cushions

E2020 Movable Furnishings


The assessment of movable furnishings, such as art work, tables, chairs, etc., is outside the
scope of this document.

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-96
02/29/12

Special Construction & Demolition

Life-Cycle Estimates:
Interior Swimming Pools
Item:

Years

Item:

Years

Surface Vinyl
Surface Concrete
Surface Gunite
Surface - Metal
Surface Tile
Surface Fiberglass
Pumps
Motors

20
30
30
20
30
40
15
15

Controls
Water Heaters
Piping and Fittings
Valves
Water Filters
Chlorinators
Underwater Lights

15
15
30
15
15
15
10

F10 Special Construction


F1010 Special Structures
The assessment guidance for the subsystems included in this section (pre-engineered
buildings, exterior utility buildings, and other special construction) will be the same as the
assessment guidance for a regularly constructed building.

F1020 Integrated Construction


The assessment guidance for the subsystem included in this section (special purpose rooms)
will be the same as the assessment guidance for a regularly constructed building.

F1030 Special Construction Systems


Checks to be made:
1. Vaults
Damaged structure or door
Damage/missing hardware or locking mechanism

F1050 Special Controls and Instrumentation


The assessment guidance for Special Controls and Instrumentation will be the same as the
assessment guidance for a regularly constructed building.

F20 Selective Building Demolition


Although Uniformat II includes this section for demolition, the assessment guidance found in
the previous sections will determine whether a building requires demolition. Therefore, the
following subsystems will not have assessment guidance:

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-97
02/29/12

F2010 Building Elements Demolition


F2020 Hazardous Components Abatement

G20 Site Improvements


G204005 Signage
Signage is used to provide graphic presentation of direction, identification, information,
regulation warning or restriction. Signs are constructed of wood, metal, concrete,
masonry/stone or various combinations of these materials.

Wood signage checks to be made:

Loose, damaged, illegible or missing sign face


Splits/cracks/broken posts: separated surface fibers, less than 25 percent of thickness
affected; separated surface fibers, greater than 25 percent of thickness affected;
physically damaged and broken
Rot, fungus or decay of posts: moist stained area; discolored, soft or crushed area
Parasite damage of posts: holes less than 1/8", surface, sag, and frass; large holes
greater than 1/8", surface channels, punctures, and crushing
Out of level: less than or equal to 3" in 4'; more than 3" in 4'
Out of plumb: less than or equal to 3" in 8'; more than 3" in 8'
Erosion/vegetation: soil erosion around posts; vines, trees or shrubs climbing over or
obscuring sign

Metal signage checks to be made:

Loose, damaged, illegible or missing sign face


Out of level: less than or equal to 3" in 4'; more than 3" in 4'
Out of plumb: Less than or equal to 3" in 8'; More than 3" in 8'
Corrosion of posts: surface corrosion, no pitting evident; corrosion evidenced by pitting
or blistering; rust/corrosion evidenced loss of base metal
Erosion/vegetation: soil erosion around posts; vines, trees or shrubs climbing over or
obscuring sign

Concrete signage checks to be made:

Loose, damaged, illegible or missing sign face


Cracking: hairline cracks; medium cracks 1/16" wide; wide cracks more than 1/16"
wide; disintegration of concrete surfaces, with loss of surface exceeding depth of 2"
Spalling: Less than 1" deep or 6" in diameter; more than 1" deep or 6" in diameter, or
loss of more than 10 percent of surface area of a member; disintegration of surface
area, with corrosion of exposed reinforcing steel
Scaling: loss of surface up to 1/2" deep, with exposure of coarse aggregates; loss of
surface from 1/2" to 1" deep with coarse aggregates clearly exposed; loss of surface
exceeds 1", reinforcing steel usually exposed
Reinforcing steel corrosion: rusting/discoloration evident, cracks occurring parallel to
reinforcement
Out of level: less than or equal to 3" in 4'; more than 3" in 4'
Out of plumb: less than or equal to 3" in 8'; more than 3" in 8'

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: BUILDINGS

Page:
Date:

12B.4-98
02/29/12

Erosion/vegetation: soil erosion around posts; vines, trees or shrubs climbing over or
obscuring sign

Masonry/stone signage checks to be made:

Loose, damaged, illegible or missing sign face


Deteriorated mortar joint material: cracked mortar joint material; loose/missing mortar
joint material
Out of level: less than or equal to 2" in 8'; more than 2" in 8'
Out of plumb: less than or equal to 3" in 8'; more than 3" in 8'
Damage bricks, stones or CMU: Cracked, split, damaged; loose or missing
Erosion/vegetation: soil erosion around sign footing; vines, trees or shrubs climbing
over or obscuring sign

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: MAINTAINED


LANDSCAPE

Page:
Date:

12B.5-1
02/29/12

Section Contents
Introduction Facility Class ................................................................................................................ 2
Facility Type Inventory Maintained Landscape ............................................................................. 3
Life-Cycle Estimates ........................................................................................................................ 4
Fencing and Gates ........................................................................................................................... 5
Irrigation ........................................................................................................................................... 8
Planting Area .................................................................................................................................. 10
Retaining Walls .............................................................................................................................. 11
Turf/Grass ...................................................................................................................................... 12
Trees .............................................................................................................................................. 13

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: MAINTAINED


LANDSCAPE

Page:
Date:

12B.5-2
02/29/12

Introduction Facility Class


The condition assessment should include a complete visual assessment of all architectural,
civil/structural, electrical, and mechanical components where applicable. Perform the field
assessment using both a system and component assessment method to identify all maintenance
and repair deficiencies that need correction. The engineer/engineering technician should
determine if there is sufficient evidence to warrant complete replacement of a system versus
repairing only specific system parts. For example, it may be sufficient to replace sections of
irrigation piping in lieu of replacing all piping and sprinkler heads.
Utilize a systematic approach to visual assessments to document all revealed problems. Some
deficiencies announce themselves, such as a crack or spalling of concrete. However, many
deficiencies are more subtle and will require further examination. During the assessment, the
engineer/engineering technician should thoroughly document the information needed in the
preparation of cost estimates and assessment reports. At a minimum, record the following should
be recorded for each deficiency:

Specify the corrective action with the appropriate verb (e.g. repair, replace, trim, remove, and reseed).

Define the deficiency (e.g. cracked 2" PVC pipe, trim 6" tree limb 20' high, reseed 100
SF of missing grass, replace 20' of rotten planting boarder).

Provide location data (e.g. northeast irrigation system, 12" Oak tree south of main
building, or throughout seasonal planting area west of building).

Quantify data in sufficient detail to permit later development of budget level cost
estimates (e.g. 120 square yards of sod, 220 linear feet of piping, or seven each).

Note: The results of the visual assessment are not intended be used for capacity planning,
environmental design, etc. If these topics are of particular interest, perform specialized
assessments and analyses.
The following document will provide guidance for the assessment of the Maintained Landscape
class. A list of life-cycle estimates has been provided for actions ranging from recurring
maintenance tasks to major system replacements. The life-cycle estimates assume that each
component will experience normal wear-and-tear and that proper maintenance and repair is
provided over the life cycle. Use these estimates as general guidance, noting any deviation
based on local conditions or facility usage as described below.
In some cases, local conditions may alter the life-cycle estimates. The life-cycle estimates may
require alteration due to the different levels of activity. For example, airports using non-treated
water will likely require irrigation sprinkler head replacement more frequently than an airport using
treated water. Once again, use the life-cycle estimates as general guidance and make note of
any deviation.

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: MAINTAINED


LANDSCAPE

Page:
Date:

12B.5-3
02/29/12

Facility Type Inventory Maintained Landscape


In addition to gathering deficiency information during the field assessment phase, the
engineer/engineering technician will gather and/or verify information associated with systems and
their components.

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: MAINTAINED


LANDSCAPE

Page:
Date:

12B.5-4
02/29/12

Life-Cycle Estimates
Controls
Fencing/Gates Wood
Fencing/Gates Metal
Fencing/Gates Concrete
Fencing/Gates Masonry/Stone
Motors
Piping and Fittings
Herbaceous annuals,
bulbs/perennials in seasonal floral
displays
Perennials, turf, and groundcovers
with a life expectancy of 1-5 years

15
10
20
30
33
15
30
1

Tree, shrub, perennials, turf, and


groundcover species with a life expectancy of 5-10 years
Tree, shrub, perennials, turf, and
groundcover species with a life expectancy of 10 - 20 years

10

Mulched surface areas


Pumps
Pump Seals
Sprinklers
Tanks Fiberglass
Tanks Metal
Valves
Tree, shrub, perennials, and
groundcover species with a life expectancy of 20-50 years
Tree, shrub, perennials, and
groundcover species with a life expectancy of 50-100 years
Tree and shrub species with a life
expectancy of 100+ years

1
15
7
5
40
25
10
50

100

100

20

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: MAINTAINED


LANDSCAPE

Page:
Date:

12B.5-5
02/29/12

Fencing and Gates


A fence consists of a line of posts secured to the ground and connected with railing, pickets,
planks, braces and other fence members secured in place. Check posts out of plumb by eye
sight, string line, or by transit. Wood gates are constructed with wood rails, pickets, planks,
braces and other members securely fastened into a single unit. Metal gates are fabricated with
pipe/tube framing covered with metal chain link or other woven wire mesh preformed panel or
metal laced fabric and kept in shape with wires, rods or turn buckles. Security components such
as barbed, razor or concertina wire may be installed around the top of a fence, either directly to
the posts or on a metal angle bracket attached to top of the posts.

Checks to be made:
1. Fencing & Gates: Fence Panels Wood
Splitting, cracking, or broken panels: Separated surface fibers extending over
entire member, less than 25 percent of thickness affected; separated surface
fibers extending over entire member, greater than 25 percent of thickness
affected; physically damage
Rot, fungus or decay: moist stained area; discolored, soft, or crushed area
Parasite damage: holes less than 1/8" diameter, surface sag, and frass; large
holes greater than 1/8" diameter, surface channels, punctures, and crushing
Out of plumb: more than 3" in 8'
Erosion/vegetation: soil erosion under fence wall; vines, trees or shrubs climbing
over or growing into fence
2. Fencing & Gates: Fence Panels Metal
Defective fence fabric: loose or sagging fence fabric greater than 2" in 8';
damaged or missing fence fabric
Defective fence panels: loose fence panels; damaged or missing fence panels.
Loose connections/anchorage: loose bolts or wire fasteners; loose or bent railing;
missing or broken components
Out of plumb: more than 3" in 8'
Corrosion: missing protective coating-galvanizing/paint no pitting evident;
corrosion evidenced by pitting or blistering; rust/corrosion evidenced by loss of
base metal
Erosion/vegetation: soil erosion under fence wall; vines, trees or shrubs climbing
over or growing into fence
3. Fencing & Gates: Fence Panels Concrete
Cracking: hairline cracks to 1/16" wide; wide cracks more than 1/16" wide;
disintegration of concrete surfaces, with loss of surface exceeding depth of 2"
Spalling: less than 1" deep or 6" in diameter; more than 1" in depth or greater
than 6" in diameter, or loss of more than 10 percent of surface area of a member;
disintegration of surface area, with corrosion of exposed reinforcing steel
Scaling: loss of surface up to 1/2" deep, with exposure of coarse aggregates;
loss of surface from 1/2" to 1" deep with coarse aggregates clearly exposed; loss
of surface exceeds 1", reinforcing steel usually exposed
Reinforcing steel corrosion: rusting/discoloration evident, cracks occurring
parallel to reinforcement
Out of plumb: more than 3" in 8'
Erosion/vegetation: soil erosion under fence walls; vines, trees or shrubs
climbing over or growing into fence

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: MAINTAINED


LANDSCAPE

Page:
Date:

12B.5-6
02/29/12

4. Fencing & Gates: Fence Panels Masonry/Stone


Deteriorated mortar joint material: cracked mortar joint material; loose/missing
mortar joint material; eroded mortar greater than 1/2" deep
Out of plumb: more than 3" in 8'
Damaged bricks, stones or CMU: cracked, split, damaged; loose, missing
Erosion/vegetation: soil erosion under fence wall; vines, trees or shrubs climbing
over or growing into fence
5. Fencing & Gates: Fence Posts Wood
Splitting, cracking, or broken posts: Separated surface fibers extending over
entire member, less than 25 percent of thickness affected; separated surface
fibers extending over entire member, greater than 25 percent of thickness
affected; physically damage.
Rot, fungus or decay: moist stained area; discolored, soft, or crushed area
parasite damage: holes less than 1/8" diameter, surface, sag, and frass; large
holes greater than 1/8" diameter surface channels, punctures, and crushing
out of plumb: more than 3" in 8'
erosion/vegetation: soil erosion around posts; vines, trees or shrubs climbing
over or around posts
6. Fencing & Gates: Fence Posts Metal
Loose connections/anchorage: loose bolts or wire fasteners; loose or bent pipe
posts or railing; missing or broken components
Out of plumb: more than 3" in 8'
Corrosion: missing protective coating-galvanizing/paint no pitting evident;
corrosion evidenced by pitting or blistering; rust/corrosion evidenced loss of base
metal
Erosion/vegetation: soil erosion around posts; vines, trees or shrubs climbing
over or around posts
7. Fencing & Gates: Fence Posts Concrete
Cracking: hairline crack; wide cracks more than 1/16" wide; disintegration of
concrete surfaces, with loss of surface exceeding depth of 2"
Spalling: less than 1" deep or 6" in diameter; more than 1" in depth or greater
than 6" in diameter, or loss of more than 10 percent of surface area of a member;
disintegration of surface area, with corrosion of exposed reinforcing steel
Scaling: loss of surface up to 1/2" deep, with exposure of coarse aggregates;
loss of surface from 1/2" to 1" deep with coarse aggregates clearly exposed; loss
of surface exceeds 1", reinforcing steel usually exposed
Reinforcing steel corrosion: rusting/discoloration evident, cracks occurring
parallel to reinforcement
Out of plumb: more than 3" in 8'
Erosion/vegetation: soil erosion around posts; vines, trees or shrubs climbing
over or around posts
8. Fencing & Gates: Fence Piers Masonry/Stone
Deteriorated mortar joint material: cracked mortar joint material; loose/missing
mortar joint material
Out of plumb: more than 3" in 8'
Damage bricks, stones or CMU: cracked, split, damaged; loose, missing
Erosion/vegetation: soil erosion around piers; vines, trees or shrubs climbing
over or around piers

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: MAINTAINED


LANDSCAPE

Page:
Date:

12B.5-7
02/29/12

9. Fencing & Gates: Gates Wood


Defective gate: Separated surface fibers extending over entire member, less than
25 percent of thickness affected; separated surface fibers extending over entire
member, greater than 25 percent of thickness affected; damaged or missing wood
sections
Rot, fungus or decay: moist stained area; discolored, soft or crushed area
Parasite damage: holes less than 1/8" diameter, surface sag, and frass; large
holes greater than 1/8" diameter, surface channels, punctures, and crushing
Out of plumb: more than 3" in 6'
Connections: loose wood at connection site; broken, split, or damaged wood at
connection site
Missing fasteners or anchorage
10. Fencing & Gates: Gates Metal
Defective gate fabric: loose or sagging gate fabric; damaged or missing gate
fabric
Defective gate panels: loose gate panels; damaged or missing gate panels
Loose connections: loose bolts or wire fasteners; loose or bent pipe post/bracing;
missing or broken hinges, latches or other components
Out of plumb: more than 1/2" in 6'
Corrosion: missing protective coating-galvanizing/paint no pitting evident;
corrosion evidenced by pitting or blistering; corrosion evidenced by loss of base
metal
11. Fencing & Gates: Security Wires
Loose connections: loose brackets or bolts; missing or broken brackets or bolts
Defective wire: loose or sagging wire; broken or missing wire
Corroded wire: missing protective coating-galvanizing/paint no pitting evident;
corrosion evidenced by loss of base metal
Corroded brackets: missing protective coating-galvanizing/paint no pitting
evident; corrosion evidenced

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: MAINTAINED


LANDSCAPE

Page:
Date:

12B.5-8
02/29/12

Irrigation
An irrigation system is a potable water distribution system used to maintain and promote
vegetation growth in specific landscape areas. The irrigation system includes backflow
preventers, valves, pumps, pipe, sprinkler heads, and tanks as components of the system.

Checks to be made:
1. Backflow Preventer
Verify annual testing for public health requirements
Non-functioning check valves
2. Valves
Leaking valves, packing glands/gaskets, broken/missing valve handles, bent
valve stems, and/or cracked valve bodies
Corrosion
3. Pumps
Physical damage, cracked or damaged pump housing, and/or broken pump base
Excessive pump noise and vibration
Loose, broken or missing pump assembly/mounting bolts
Leakage
Deteriorated or corroded protective covering
Problems priming or engaging pump
Pest problems
4. Pump Base and Coupling
Loose, broken or missing pump/motor assembly/mounting bolts
Loose/missing set screws, defective couplings, and/or loose/missing coupling
guards
Deterioration of protective covering/corrosion
Abandoned pump assemblies that require disposal
5. Pump Controls
Electrical arcing noise
Damage, damage to control panel, burned out pilot lamps, and/or access to panel
blocked
Deterioration of protective covering/corrosion
Malfunctioning pressure gauges
6. Pipe
Bent/cracked fittings and/or signs of leakage
Bent/cracked pipes and/or signs of leakage
Loose supports or hangers, and/or broken/missing supports or hangers
Loose, damaged, deteriorated, and/or missing insulation
Galvanic anode cathode protection system for reduction in thickness and/or loose
fasteners or broken welds
Corrosion, pitting, blistering, and/or loss of base metal
Impressed current cathode protection system
Plugging/clogging
7. Sprinkler Heads
Damaged or broken head (observe spray patterns while functioning)

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: MAINTAINED


LANDSCAPE

Page:
Date:

12B.5-9
02/29/12

8. Tanks
Leakage
Vandalization and/or presence of graffiti
Corrosion of metal tanks
Wear on fiberglass tanks

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: MAINTAINED


LANDSCAPE

Page:
Date:

12B.5-10
02/29/12

Planting Area
A planting area is a maintained landscape specifically designated for use of decorative or annual
vegetation.

Factors Reducing Life Expectancy


The genetic potential of vegetative features may be reduced by 10% to 95% depending on the
quantity and severity of these impacts.
Climatic Impacts
Temperature/light extremes
Precipitation/flooding/drought
Wind/snow/lightning
Severe storms
Maintenance Impacts
Stress induced by poor maintenance activities
Repeated structural damage (bark removal/injury, sign/lighting attachment, etc.)
Management Impacts
Sustained pest infestations (chronic pest damage)
Resource Management Impacts
Growth beyond design intent or functional use
Growth impacting adjacent resources, facilities or equipment
Repeated pest infestations (severe, regular/recurring pest damage)
Site Impacts
Harsh growing environments (urban conditions, roadside salt, pavement restrictions, compacted soil etc.)
Restrictive site conditions (small planting boxes, etc.)

Checks to be made:
1. Planting Area
Compacted soil
Improper soil fertility/pH/moisture
Poor soil texture/structure
Soil erosion or build up
Presence of holes, burrows, ruts, or depressions
Further assessment/testing required
Inadequate mulching or fertilization
Damaged/missing, uplifted, sharp or settled edging

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: MAINTAINED


LANDSCAPE

Page:
Date:

12B.5-11
02/29/12

Retaining Walls
These are structures used to prevent the flow or lateral movement of soil. Assemblies exist for
cast-in-place concrete retaining walls.

Checks to be made:
1. Retaining Walls
Leaning and bulges
Creepers and vines causing damage (paint peeling, joint deterioration etc.)
Plants holding water against structure
Tree roots damaging structure
Insect/termite infestation and decay on wood members
Masonry and mortar: pay particular attention to loose mortar joints, cracks, stains
and wet spots on the wall
Cracks: Cracks can be horizontal, vertical, diagonal, hairline or major. Document
the nature of the crack, explaining as best as possible the causes of the cracks
Check mortar: inspect mortar joints to determine if they are loose or missing and
evaluate their condition as good, fair or poor
Check brick: stains, wet spots, bulges, spalling, efflorescence, and missing brick.
Check stone: wet spots, stains, spalling, bulges, and florescence

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: MAINTAINED


LANDSCAPE

Page:
Date:

12B.5-12
02/29/12

Turf/Grass
Turf/grass refers to the vegetative ground cover of non-seasonal or non-decorative natural
landscapes. This will generally be limited to grass areas.

Checks to be made:
1. Turf
Thin/spotty/poorly established turf
Damaging/improper mowing
Inadequate drainage or excessive water
Improper turf species
Excessive thatch layer
Wilted/stressed turf
Presence of holes, burrows, ruts, or depressions
Edge poorly defined
Debris/organic matter on surfaces
Insect/disease/pest problems
Vandalization
Weed/exotic species problems

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: MAINTAINED


LANDSCAPE

Page:
Date:

12B.5-13
02/29/12

Trees
A tree is a perennial plant that consists of roots, trunk, secondary limbs, and foliage. A tree will
have a long life span and bear a nut, fruit, or flower.

Factors Reducing Life Expectancy


The genetic potential of vegetative features may be reduced by 10% to 95% depending on the
quantity and severity of these impacts.
Climatic Impacts
Temperature/light extremes
Precipitation/flooding/drought
Wind/snow/lightning
Severe storms
Maintenance Impacts
Stress induced by poor maintenance activities
Repeated structural damage (bark removal/injury, sign/lighting attachment, etc.)
Management Impacts
Sustained pest infestations (chronic pest damage)
Resource Management Impacts
Growth beyond design intent or functional use
Growth impacting adjacent resources, facilities or equipment
Repeated pest infestations (severe, regular/recurring pest damage)
Site Impacts
Harsh growing environments (urban conditions, roadside salt, pavement restrictions, compacted soil etc.)
Restrictive site conditions (small planting boxes, etc.)

Checks to be made:
1. Trees
Plant health/vigor problems
Flowers/fruit problems (insect, disease, or pest damage)
Trunk/root problems or defects (gouges, mechanical damage, root rot, gidling or
exposed roots, materials embedding, etc.)
Excessive/irregular plant growth
Foliage problems (insect damage/disease, chlorotic, wilting, etc.)
Branch/limb problems (cracked, dead, broken, hazard/safety issues etc.)
Inappropriate size and shape
Weed/exotic species problems
Density problems/plant mortality
Vegetation overgrowth
Inadequate mulching
Damaged/improperly installed/removed components (tree staking, guy wires, cable and bracing, lightning protection)
Vandalization
Damaged, missing, uplifted, sharp or settled edging

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: LANDSIDE SIGNS

Page:
Date:

12B.6-1
02/29/12

Section Contents
Introduction Facility Class ................................................................................................................ 2
Facility Type Inventory Landside Signs ........................................................................................ 3
Life-Cycle Estimates ........................................................................................................................ 4
Signs ................................................................................................................................................ 5

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: LANDSIDE SIGNS

Page:
Date:

12B.6-2
02/29/12

Introduction Facility Class


The condition assessment should include a complete visual assessment of all architectural,
civil/structural, electrical, and mechanical components where applicable. Perform the field
assessment using both a system and component assessment method to identify all maintenance
and repair deficiencies that need correction. The engineer/engineering technician should
determine if there is sufficient evidence to warrant complete replacement of a system versus
repairing only system parts.
Utilize a systematic approach to visual assessments to document all revealed problems. Some
deficiencies announce themselves, such as a crack or spalling of concrete. However many
deficiencies are more subtle and will require further examination. During the assessment, the
engineer/engineering technician should thoroughly document the information needed in the
preparation of cost estimates and assessment reports. At a minimum, record the following for
each deficiency:

Specify the corrective action with the appropriate verb (e.g. repair, replace, prepare
and paint, remove).

Define the deficiency (e.g. rotted wood, damaged masonry).

Provide location data (e.g. south of building name or along/throughout entire


facility).

Quantify data in sufficient detail to permit later development of budget level cost
estimates (e.g. metal sign 4' long by 2' high, or 7 each).

Note: The results of the visual assessment are not intended be used for capacity planning,
environmental design, etc. If these topics are of particular interest, perform specialized
assessments and analyses.
The following document will provide guidance for the assessment of the Landside Sign facility
class. A list of life-cycle estimates has been provided for actions ranging from recurring
maintenance tasks to major system replacements. The life-cycle estimates assume that each
component will experience normal wear-and-tear and that proper maintenance and repair is
provided over the life cycle. Use these estimates as general guidance, noting any deviation
based on local conditions or facility usage as described below.
In some cases, local conditions may alter the life-cycle estimates. The life-cycle estimates may
require alteration due to the different levels of activity. For example, metal signs at an airport near
salt water will likely require replacement more frequently than at an airport located inland. Once
again, use the life-cycle estimates as general guidance and make note of any deviation.

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: LANDSIDE SIGNS

Page:
Date:

12B.6-3
02/29/12

Facility Type Inventory Landside Signs


In addition to gathering deficiency information during the field assessment phase, the
engineer/engineering technician will gather and/or verify information associated with systems and
their components.

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

ASSESSMENT GUIDE: LANDSIDE SIGNS

12B.6-4
02/29/12

Life-Cycle Estimates
Item:

Years

Item:

Years

Signage Wood
Signage Concrete

10
30

Signage Metal
Signage Masonry/Stone

20
30

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: LANDSIDE SIGNS

Page:
Date:

12B.6-5
02/29/12

Signs
Signage is used to provide graphic presentation of direction, identification, information, regulation
warning or restriction. Signs are constructed of wood, metal, concrete, masonry/stone or various
combinations of these materials.

Checks to be made:
1. Wood
Loose, damaged, illegible or missing sign face
Splits/cracks/broken posts: separated surface fibers, less than 25 percent of
thickness affected; separated surface fibers, greater than 25 percent of thickness
affected; physically damaged and broken posts
Rot, fungus or decay of posts: moist stained area; discolored, soft, or crushed
area
Parasite damage of posts: holes less than 1/8" with surface, sag, and frass; large
holes greater than 1/8", surface channels, punctures, and crushing
Out of level: less than or equal to 3" in 4'; more than 3" in 4'
Out of plumb: less than or equal to 3" in 8'; more than 3" in 8'
Erosion/vegetation: soil erosion around posts; vines, trees or shrubs climbing
over or obscuring sign
2. Metal
Loose, damaged, illegible or missing sign face
Out of level: less than or equal to 3" in 4'; more than 3" in 4'
Out of plumb: less than or equal to 3" in 8'; more than 3" in 8'
Corrosion of posts: surface corrosion no pitting evident; corrosion evidenced by
pitting or blistering; rust/corrosion evidenced loss of base metal
Erosion/vegetation: soil erosion around posts; vines, trees or shrubs climbing over
or obscuring sign
3. Concrete
Loose, damaged, illegible or missing sign face
Cracking: hairline crack; medium cracks 1/16" wide; wide cracks more than 1/16"
wide; disintegration of concrete surfaces, with loss of surface exceeding depth of
2"
Spalling: less than 1" deep or 6" in diameter; more than 1" in depth or greater
than 6" in diameter, or loss of more than 10 percent of surface area of a member;
disintegration of surface area, with corrosion of exposed reinforcing steel
Scaling: loss of surface up to 1/2" deep, with exposure of coarse aggregates; loss
of surface from 1/2" to 1" deep with coarse aggregates clearly exposed; loss of
surface exceeds 1", reinforcing steel usually exposed
Reinforcing steel corrosion: rusting/discoloration evident, cracks occurring parallel
to reinforcement
Out of level: less than or equal to 3" in 4'; more than 3" in 4'
Out of plumb: less than or equal to 3" in 8'; more than 3" in 8'
Erosion/vegetation: soil erosion around posts; vines, trees or shrubs climbing
over or obscuring sign
4. Masonry/Stone
Loose, damaged, illegible or missing sign face
Deteriorated mortar joint material: cracked mortar joint material; loose/missing
mortar joint material
Out of level: less than or equal to 2" in 8'; more than 2" in 8'

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: LANDSIDE SIGNS

Page:
Date:

12B.6-6
02/29/12

Out of plumb: less than or equal to 3" in 8'; more than 3" in 8'
Damaged bricks, stones or CMU: cracked, split, damaged; loose, missing
Erosion/vegetation: soil erosion around sign footing; vines, trees or shrubs
climbing over or obscuring sign

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: LANDSIDE


LIGHTING

Page:
Date:

12B.7-1
02/29/12

Section Contents
Introduction Facility Class ................................................................................................................ 2
Facility Type Inventory Landside Lighting ..................................................................................... 3
Life-Cycle Estimates ........................................................................................................................ 4
Circuits ............................................................................................................................................. 5
Controls ............................................................................................................................................ 6
Light Fixtures .................................................................................................................................... 7

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: LANDSIDE


LIGHTING

Page:
Date:

12B.7-2
02/29/12

Introduction Facility Class


The condition assessment should include a complete visual assessment of all architectural,
civil/structural, electrical, and mechanical components where applicable. Perform the field
assessment using both a system and component assessment method to identify all maintenance
and repair deficiencies that need correction. The engineer/engineering technician should
determine if there is sufficient evidence to warrant complete replacement of a system versus
repairing only system parts.
Utilize a systematic approach to visual assessments to document all revealed problems. Some
deficiencies announce themselves, such as a crack or spalling of concrete. However, many
deficiencies are more subtle and will require further examination. During the assessment, the
engineer/engineering technician should thoroughly document the information needed in the
preparation of cost estimates and assessment reports. At a minimum, record the following for
each deficiency:

Specify the corrective action with the appropriate verb (e.g. repair, replace, adjust,
and remove).

Define the deficiency (e.g. broken lens, missing cover).

Provide location data (e.g. north exterior of "building name", in room 123, or south
of "building name").

Quantify data in sufficient detail to permit later development of budget level cost
estimates (e.g. 24 x 24 cover or seven each).

Note: The results of the visual assessment are not intended be used for capacity planning,
environmental design, etc. If these topics are of particular interest to the site, perform specialized
assessments and analyses.
The following document will provide guidance for the assessment of the Landside Lighting facility
class. A list of life-cycle estimates has been provided for actions ranging from recurring
maintenance tasks to major system replacements. The life-cycle estimates assume that each
component will experience normal wear-and-tear and that proper maintenance and repair is
provided over the life cycle. Use these estimates as general guidance, noting any deviation
based on local conditions or facility usage as described below.
In some cases, local conditions may alter the life-cycle estimates. The life-cycle estimates may
require alteration due to the different levels of activity. For example, equipment located outside at
an airport near salt water will likely require replacement more frequently than equipment located
indoors further inland. Once again, use the life-cycle estimates as general guidance and make
note of any deviation.

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: LANDSIDE


LIGHTING

Page:
Date:

12B.7-3
02/29/12

Facility Type Inventory Landside Lighting


In addition to gathering deficiency information during the field assessment phase, the
engineer/engineering technician will gather and/or verify information associated with systems and
their components.

2012 City of Los Angeles. All rights reserved.

Page:
Date:

Facilities Management Handbook

ASSESSMENT GUIDE: LANDSIDE


LIGHTING

12B.7-4
02/29/12

Life-Cycle Estimates
Item:

Years

Item:

Years

Lighting Controllers

15

Light Fixture

20

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: LANDSIDE


LIGHTING

Page:
Date:

12B.7-5
02/29/12

Circuits
A circuit includes the energy source, devices that use current (such as motors, lamps, and
electronics), and connecting wires or transmission lines.

Checks to be made:
1. Circuit
Corrosion, pitting, or loss of base metal
Physical damage
Improper grounding or hot spots
Damaged security door or devices
Signs of fire or scorching

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: LANDSIDE


LIGHTING

Page:
Date:

12B.7-6
02/29/12

Controls
Controls contain switches, timers, relays, and other equipment used to regulate electrical devices,
such as lights.

Checks to be made:
1. Control
Corrosion, pitting, or loss of base metal
Physical damage
Improper grounding or hot spots
Damaged security door or devices
Signs of fire or scorching

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: LANDSIDE


LIGHTING

Page:
Date:

12B.7-7
02/29/12

Light Fixtures
Lighting consists of various types, sizes, and shapes of lighting fixtures together with a wide range
of lamp sources.

Checks to be made:
1. Fixtures
Inadequately supported, insecure, and improperly located fixtures and evidence
of unauthorized removal
Incorrect types installed in hazardous locations
Cracked or broken luminaries and fixture parts
Indications of objects being supported from, or hung on fixtures
Evidence of overheating, undersized sockets, other damage to sockets, or
exposed or damaged connecting wiring
2. Lamps
Oversized lamps, blistering, loose base, thermal cracks from fixture contact, bare
lamps, or poor socket lamp connections
Operation of fluorescent fixtures showing poor burning and starting
characteristics, and loud humming ballasts

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: LANDSIDE


PAVEMENT

Page:
Date:

12B.8-1
02/29/12

Section Contents
Introduction Facility Class ................................................................................................................ 2
Facility Inventory Type Landside Pavement ................................................................................. 3
Life-Cycle Estimates ........................................................................................................................ 4
Roads ............................................................................................................................................... 5
Driveway........................................................................................................................................... 6
Parking Lot ....................................................................................................................................... 8
Pedestrian Plaza ............................................................................................................................ 11
Walkways ....................................................................................................................................... 13

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: LANDSIDE


PAVEMENT

Page:
Date:

12B.8-2
02/29/12

Introduction Facility Class


The condition assessment should include a complete visual assessment of all architectural,
civil/structural, electrical, and mechanical components where applicable. Perform the field assessment
using both a system and component assessment method to identify all maintenance and repair
deficiencies that need correction. The engineer/engineering technician should determine if there is
sufficient evidence to warrant complete replacement of a system versus repairing only system parts. For
example, it may be sufficient to fill potholes in lieu of repaving whole sections.
Utilize a systematic approach to visual assessments to document all revealed problems. Some
deficiencies announce themselves, such as a crack or spalling of concrete. However, many deficiencies
are more subtle and will require further examination. During the assessment, the engineer/engineering
technician should thoroughly document the information needed in the preparation of cost estimates and
assessment reports. At a minimum, record the following for each deficiency:

Specify the corrective action with the appropriate verb (e.g. repair, replace, prepare and
paint, repave, remove).

Define the deficiency (e.g. cracked asphalt, spalling concrete, pothole in asphalt pavement,
missing gravel).

Provide location data (e.g. northeast corner of parking lot, left lane where road meets highway, or along/throughout entire facility).

Quantify data in sufficient detail to permit later development of budget level cost estimates
(e.g. 120 square yards of concrete, or 220 linear feet of markings, or seven each).

Note: The results of the visual assessment are not intended be used for capacity planning, environmental
design, etc. If these topics are of particular interest, perform specialized assessments and analyses.
The following document will provide guidance for the assessment of the Landside Pavements facility
class. A list of life-cycle estimates has been provided for actions ranging from recurring maintenance
tasks to major system replacements. The life-cycle estimates assume that each component will
experience normal wear-and-tear and that proper maintenance and repair is provided over the life-cycle.
Use these estimates as general guidance, noting any deviation based on local conditions or facility usage
as described below.
In some cases, local conditions may alter the life-cycle estimates. The life-cycle estimates may require
alteration due to the different levels of activity. For example, the paved public roads (i.e., entrance roads,
roads between parking garages, etc.) at an airport will likely require replacement more frequently than the
paved service roads. Once again, use the life-cycle estimates as general guidance and make note of any
deviation.
This assessment guide will cover the pavements that do not require security clearance to access. Many
of these facility types have a corresponding facility type under the Airfield Pavement facility class. The
two systems are separated because of the additional cost needed to cover the security personnel and
precautions that have to be taken into account when performing the maintenance.

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: LANDSIDE


PAVEMENT

Page:
Date:

12B.8-3
02/29/12

Facility Inventory Type Landside Pavement


In addition to gathering deficiency information during the field assessment phase, the
engineer/engineering technician will gather and/or verify information associated with systems and their
components.

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: LANDSIDE


PAVEMENT

Page:
Date:

12B.8-4
02/29/12

Life-Cycle Estimates
Item:

Years

Item:

Years

Driveway Asphalt
Driveway Brick Pavers
Driveway Concrete
Driveway Earth
Driveway Gravel
Parking Lot Asphalt
Parking Lot Brick
Parking Lot Concrete
Parking Lot Earth
Parking Lot Granite Pavers
Parking Lot Gravel
Parking Lot Large Slate/
Stone Slab Pavers
Parking Lot Precast Pavers
Parking Lot Stone
Pedestrian Plaza Asphalt
Pedestrian Plaza Brick

15
25
25
100
15
20
45
35
100
35
10

Pedestrian Plaza Concrete


Pedestrian Plaza Precast
Concrete Pavers
Pedestrian Plaza Stone
Pedestrian Plaza Wood
Roads Asphalt
Roads Concrete
Roads Earth
Roads Gravel
Asphalt
Brick
Concrete
Rubber Acrylic
Slate
Stone
Wood

35

45
45
35
25
25

35
50
15
20
30
100
15
25
35
35
7
50
50
15

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: LANDSIDE


PAVEMENT

Page:
Date:

12B.8-5
02/29/12

Roads
A road is any maintained route or path designed to give motorized vehicles access from one point to
another. Public roads will commonly be designed for the use of cars, while service roads can be
designed for cars & trucks and/or smaller maintenance vehicles. The amount of traffic and initial design
work of each road will affect the design life. Public roads will be maintained at a higher level than service
roads for liability and aesthetic reasons. Some service roads are not designed for heavy usage and will
not be expected to remain as visually appealing as public roads; a continually cracking service road due
to tree roots is a good example of this. In these situations, determine the desired maintenance level
expectations of the roads.

Checks to be made:
1. Asphalt Road
Cracking, pitting, damage
Spalling
Potholes or patches
Depleted or missing surface material
Erosion problems
Unevenness, uplifting, sinking
Vandalization
Grooves
Improper drainage
Curb and gutter damage
2. Concrete Road
Cracking, pitting, damage
Spalling
Potholes or patches
Depleted or missing surface material
Erosion problems
Unevenness, uplifting, sinking
Vandalization
Grooves
Improper drainage
Missing joint material
Curb and gutter damage
Efflorescence
3. Gravel Road
Potholes
Depleted or missing surface material
Erosion
Washboarding
Improper grading
Improper drainage
Ruts
4. Earth Road
Potholes
Erosion
Washboarding
Improper grading
Improper drainage
Ruts

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: LANDSIDE


PAVEMENT

Page:
Date:

12B.8-6
02/29/12

Driveway
A driveway is the connecting route leading from a road to a facility or destination area. A driveway is
usually shorter than the road it leads from. Driveways are similar in design and maintenance to roads.

Checks to be made:
1. Asphalt Driveway
Cracking, pitting, damage
Spalling
Potholes or patches
Depleted or missing surface material
Erosion problems
Unevenness, uplifting, sinking
Vandalization
Grooves
Improper drainage
Curb and gutter damage
2. Concrete Driveway
Cracking, pitting, damage
Spalling
Potholes or patches
Depleted or missing surface material
Erosion problems
Unevenness, uplifting, sinking
Vandalization
Grooves
Improper drainage
Missing joint material
Curb and gutter damage
Efflorescence
3. Gravel Driveway
Potholes
Depleted or missing surface material
Erosion
Washboarding
Improper grading
Improper drainage
Ruts
4. Earth Driveway
Potholes
Erosion
Washboarding
Improper grading
Improper drainage
Ruts
5. Brick Paver Driveway
Cracking, pitting, damage
Spalling
Potholes or patches
Depleted or missing surface material

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: LANDSIDE


PAVEMENT

Page:
Date:

12B.8-7
02/29/12

Erosion problems
Unevenness, uplifting, sinking
Vandalization
Grooves
Improper drainage
Missing joint material
Curb and gutter damage
Efflorescence

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: LANDSIDE


PAVEMENT

Page:
Date:

12B.8-8
02/29/12

Parking Lot
A parking lot is an area specifically designed and allocated to safely leave motorized vehicles unattended.
Parking lots are generally located close to a facility or destination area entrance. Public parking lots will
require ADA access to and from the parking lot and the facility or area it serves. A separate ADA
guidance document will be available to the engineer/engineering technician performing the necessary
ADA checks. The engineer/engineering technician will also have to assess the markings, stall bumpers,
curbs, gutters, signage, and surface material of the parking lot. The team assessing the condition of
parking lots should have an agreement on the boundaries of the facility before performing the
assessment.

Checks to be made:
1. Brick Parking Lot
Cracking, pitting, damage
Spalling
Potholes or patches
Depleted or missing surface material
Erosion problems
Unevenness, uplifting, sinking
Vandalization
Grooves
Improper drainage
Missing joint material
Curb and gutter damage
Efflorescence
2. Stone Parking Lot
Cracking, pitting, damage
Potholes or patches
Depleted or missing surface material
Erosion problems
Unevenness, uplifting, sinking
Vandalization
Grooves
Improper drainage
Missing joint material
Curb and gutter damage
3. Precast Paver Parking Lot
Cracking, pitting, damage
Spalling
Potholes or patches
Depleted or missing surface material
Erosion problems
Unevenness, uplifting, sinking
Vandalization
Grooves
Improper drainage
Missing joint material
Curb and gutter damage
Efflorescence
4. Large Slate/Stone Slab Paver Parking Lot
Cracking, pitting, damage

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: LANDSIDE


PAVEMENT

Page:
Date:

12B.8-9
02/29/12

Potholes or patches
Depleted or missing surface material
Erosion problems
Unevenness, uplifting, sinking
Vandalization
Grooves
Improper drainage
Missing joint material
Curb and gutter damage

5. Granite Paver Parking Lot


Cracking, pitting, damage
Potholes or patches
Depleted or missing surface material
Erosion problems
Unevenness, uplifting, sinking
Vandalization
Grooves
Improper drainage
Missing joint material
Curb and gutter damage
6. Concrete Parking Lot
Cracking, pitting, damage
Spalling
Potholes or patches
Depleted or missing surface material
Erosion problems
Unevenness, uplifting, sinking
Vandalization
Grooves
Improper drainage
Missing joint material
Curb and gutter damage
Efflorescence
7. Asphalt Parking Lot
Cracking, pitting, damage
Spalling
Potholes or patches
Depleted or missing surface material
Erosion problems
Unevenness, uplifting, sinking
Vandalization
Grooves
Improper drainage
Missing joint material
Curb and gutter damage
Ruts
8. Gravel Parking Lot
Potholes or patches
Depleted or missing surface material
Erosion problems

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: LANDSIDE


PAVEMENT

Page:
Date:

12B.8-10
02/29/12

Unevenness, uplifting, sinking


Vandalization
Improper drainage
Curb and gutter damage
Ruts
Washboarding

9. Earth Parking Lot


Potholes or patches
Depleted or missing surface material
Erosion problems
Unevenness, uplifting, sinking
Vandalization
Improper drainage
Curb and gutter damage
Ruts
Washboarding

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: LANDSIDE


PAVEMENT

Page:
Date:

12B.8-11
02/29/12

Pedestrian Plaza
A pedestrian plaza is a paved surface where the public can congregate. A pedestrian plaza is similar to a
large patio. A pedestrian plaza can be attached or independent of a building. Some pedestrian plaza are
surrounding by merchant shops. The pedestrian plaza can include lighting, signage, markings, benches,
vegetation boarders and other common use public items. A pedestrian plaza will normally only have ADA
signage and ramp requirements to check. The ADA guide should be consulted for the specifications on
their requirements.

Checks to be made:
1. Concrete Pedestrian Plaza
Cracking, pitting, damage
Spalling
Potholes or patches
Depleted or missing surface material
Erosion problems
Unevenness, uplifting, sinking
Vandalization
Grooves
Improper drainage
Missing joint material
Efflorescence
2. Asphalt Pedestrian Plaza
Cracking, pitting, damage
Potholes or patches
Depleted or missing surface material
Erosion problems
Unevenness, uplifting, sinking
Vandalization
Grooves
Improper drainage
3. Precast Concrete Paver Pedestrian Plaza
Cracking, pitting, damage
Spalling
Potholes or patches
Depleted or missing surface material
Erosion problems
Unevenness, uplifting, sinking
Vandalization
Grooves
Improper drainage
Missing joint material
Efflorescence
4. Wood Pedestrian Plaza
Wearing
Loose boards
Broken boards
Loose / missing railing
Rot
Improper drainage
Insect damage

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: LANDSIDE


PAVEMENT

Page:
Date:

12B.8-12
02/29/12

Vandalization
Uneven surfaces

5. Brick Pedestrian Plaza


Cracking, pitting, damage
Spalling
Potholes or patches
Depleted or missing surface material
Erosion problems
Unevenness, uplifting, sinking
Vandalization
Grooves
Improper drainage
Missing joint material
Efflorescence
6. Stone Pedestrian Plaza
Cracking, pitting, damage
Potholes or patches
Depleted or missing surface material
Erosion problems
Unevenness, uplifting, sinking
Vandalization
Grooves
Improper drainage
Missing joint material

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: LANDSIDE


PAVEMENT

Page:
Date:

12B.8-13
02/29/12

Walkways
A walkway is a designed surface intended for non-motorized vehicle use. A walkway excludes bridges
and tunnels because they will be collect under their own facility types. Common associated items with
walkways are signage, markings, railings, steps, and ramps. The normal ADA items to check on
walkways are proper signage and surface slope degree. The ADA guide should be consulted for the
specifications on their requirements.

Checks to be made:
1. Slate Walkway
Cracking, pitting, damage
patches
Depleted or missing surface material
Erosion problems
Unevenness, uplifting, sinking
Vandalization
Improper drainage
Missing joint material
2. Brick Walkway
Cracking, pitting, damage
Spalling
Potholes or patches
Depleted or missing surface material
Erosion problems
Unevenness, uplifting, sinking
Vandalization
Grooves
Improper drainage
Missing joint material
Efflorescence
3. Stone Walkway
Cracking, pitting, damage
Potholes or patches
Depleted or missing surface material
Erosion problems
Unevenness, uplifting, sinking
Vandalization
Improper drainage
Missing joint material
4. Concrete Walkway
Cracking, pitting, damage
Spalling
Potholes or patches
Depleted or missing surface material
Erosion problems
Unevenness, uplifting, sinking
Vandalization
Grooves
Improper drainage
Missing joint material
Efflorescence

2012 City of Los Angeles. All rights reserved.

Facilities Management Handbook

ASSESSMENT GUIDE: LANDSIDE


PAVEMENT

Page:
Date:

12B.8-14
02/29/12

5. Asphalt Walkway
Cracking, pitting, damage
Spalling
Potholes or patches
Depleted or missing surface material
Erosion problems
Unevenness, uplifting, sinking
Vandalization
Grooves
Improper drainage
Missing joint material
6. Rubber Acrylic Walkway
Cracking, pitting, damage
Potholes or patches
Depleted or missing surface material
Erosion problems
Unevenness, uplifting, sinking
Vandalization
Improper drainage
Ruts
7. Wood Walkway
Wearing
Loose boards
Broken boards
Loose / missing railing
Rot
Improper drainage
Insect damage
Vandalization
Uneven surfaces

2012 City of Los Angeles. All rights reserved.