Size of Vertical Gates

No.
size
2
0.75 * 1.25
2
0.75 * 1.65
2
1.00 * 1.2
2
1.00 * 1.60
2
1.00 * 2.65
2
1.20 * 1.90
2
1.30 * 1.50
2
1.40 * 1.85
2
1.50 * 1.25
2
1.60 * 1.10
2
1.60 * 2.30
2
1.75 * 1.80
2
1.90 * 2.45
2
1.90 * 3.35
2
2.00 * 2.35

Cross Regulator At Chainage 8983 m. of Pipli Distributory (LD-3B) Offtaking 63625 m.


of Vallabhipur Sub Branch Canal
1.0 Data :Sr. No.

Parameters

U/S

D/S

Units
m3 / sec.

( i ) Canal Discharge
( ii ) Canal Bed Width

6.5739
1.15

6.5739
1.1

( iii ) Full Supply Depth


( iv ) Full Supply Level

1.84
14.46

1.79
14.41

m.
m.

( v ) Canal Bed Level


( vi ) Free Board

12.62
0.55

12.62
0.55

m.
m.

( vii ) Top Bank Level


( viii ) Side slope (inner)(H:V

15.01
1.5:1

14.96
1.5:1

m.

( ix ) Side slope (outer)(H:


( x ) Natural Surface Level

2.0:1
10.239

2.0:1

m.

m.

2.0 Hydraulic Design :2.1 Water way :Since the canal is lined, the clear linear waterway has been kept equal to
the average width of canal with marginal adjustment.
Top width at F.S.L. =1.1 + 2 * 1.79 * 1.5 = 6.47 m.
Clear waterway = (D/S bed width + top width at FSL) / 2
Clear waterway = (1.1 + 6.47) / 2 = 3.785 m.
FSL 14.41 m.
1

1.79 m.
1.5

1
1.5
CBL 12.62 m.

1.1 m.
D/S Canal Section
Provide no. of spans 2
Each span = Clear waterway / no. of spans =
3.785 / 2 = 1.893 m.
So provide span of gate section =
1.9
m
Thickness of section =
0.6
m
However Provide 2 spans each of 1.9 m. & pier each of 0.6 m. thickness for fixing the gate.
Overall linear waterway = (No. of spans * width of clear span) + (no. of piers * pier thickness) =
(2 * 1.9) + (1 * 0.6) 4.4 m.

Number of vertical gates to be provided = 2


Height of gate = (U/S F.S.L. + 0.5) - Crest R.L.

Provide Gate Size = 1.9 * 2.45


Effective width provided = span length * no. of spans = 1.9 *3.8 m.

2.2 Crest Design :( i ) Crest Level :Crest has been provided 15 cm. above U/S or D/S CBL whichever is higher.
Crest level = max.(U/S CBL,D/S CBL) + 0.15
Crest level = MAX(12.62,12.62) + 0.15 = 12.77 m.
Provide Crest level at E.L. 12.77 m.
( ii ) Crest Width :U/S T.E.L. = U/S F.S.L. + Va2 / 2g
where, Va = Approach velocity i.e. Designed canal velocity in U/S.
g = Acceleration due to gravity = 9.81 m / sec2
Q = A * Va Va = Q / A
Va = Q / (b + nd) * d =
Va = 6.5739 / (1.15 + 1.5 * 1.84) * 1.84 =
U/S T.E.L. = 14.46 + (0.914^2 / (2*9.81)) =
D/S T.E.L. = D/S F.S.L. + Va2 / 2g
Va = 6.5739 / (1.1 + 1.5 * 1.79) * 1.79 =

0.914 m / sec.
14.503 m.

0.97 m / sec.
D/S T.E.L. = 14.41 + (0.97^2 / (2*9.81)) =
14.458 m.
As per IS:7114-1973 Cl. 3.2.1 Crest width shall be fixed to a minimum of 2 / 3 H.
where, H is the head over the crest.
H = U/S T.E.L. - Crest E.L.
H = 14.503 - 12.77 =
Crest width = (2 / 3) * 1.733 =
Provide crest width = 1.2 m.

1.733 m.
1.155 m.

2.3 Head loss calculation :(Reference-IS - 7114-1973-cl-4.1)


Canal bed level at D/S =

12.62

Full supply at level D/S =


Full supply depth at D/S =
Area at D/S canal section =

14.41
1.79
6.776

m
m
m2

Velocity at D/S = Discharge / Area =


Velocity head
=
=
=

0.971
V 2 / 2*g

m/sec

(0.971*0.971)/(2*9.81)
0.049

Area of gate section

2 * 1.9 * 1.79

Velocity at section

=
=

6.802
6.5739 / 6.802

Velocity head

=
=

0.967
(0.967 * 0.967)/(2*9.81)
0.048

Change in velocity head


Loss at exit

m2

0.001
0.5 * 0.001
0.0005

0.0005 < 0.05 so size of gate bay is ok


2.4 Cistern Design :( i ) Length of cistern
Discharge/Rmt = D/S Discharge/Effective width = 6.5739 / 3. 1.73 cumecs / Rmt.
HL = U/S F.S.L. - D/S F.S.L. = 14.46 - 14.41 =

HL = 0.05 m.
From Theory and design of irrigation structure Vol-II Varshney and Gupta Blench Curve (fig. 2.5),Page - 40
Ef2 = #VALUE!

#VALUE! #VALUE!
m.
Also, length of cistern = 5 * D/S F.S.D. = 5 * 1.79 = 8.95 m.
Provide length of cistern = #VALUE!
m.
( ii ) Cistern Level :Depth of cistern is designed on the following conditions whichever is lower.
( i ) Cistern RL = D/S T.E.L. - 1.25 Ef2
#VALUE!

#VALUE!
m.

( ii ) Cistern RL = D/S T.E.L. - D/S F.S.D. / 3


Cistern RL = 14.458 - (1.79 / 3) =
13.861m.
( iii ) Cistern RL = D/S F.S.L. - 1.25 * dx
where, x = 0.98 * q0.52 * HL0.21
x = 0.98 * 1.73 ^ 0.52 * 0.05 ^ 0.21 =
Cistern RL = 14.41 - 1.25 * 0.695 =
13.541m.
( iv ) Cistern RL = D/S C.B.L. - 0.5
Cistern RL = 12.62 - 0.5 =
12.12 m.
#VALUE!

0.695

2.5 Check for Uplift Pressure, Exit Gradient & Floor Thickness :( i ) Uplift Pressure Calculation :Crest EL 12.77 m.
U/S CBL 12.62 m.

D/S CBL 12.62 m.


#VALUE!

NSL 10.239 m.
Foundation EL 8.739 m.
1.2

#VALUE!

#VALUE!

#VALUE!

0.15
#VALUE!
Section showing elevation of Crest & Cistern

12.62

1
11.62
D1'

D'
Depressed Floor

For the Uplift pressure calculation(using Khosla's theory), base slab


has been idealized as depressed floor of uniform thickness as shown in the fig. above.
#VALUE!
#VALUE!
Thickness of depressed floor = 1 m.

Maximum static head = 1.84 m.


value of 1 / = d / b =
#VALUE!
#VALUE!
= #VALUE!
= (1 + (1 + a2))/2 =
#VALUE!
= #VALUE!
Percentage pressure at the D/S point D' = D' = D - 2/3 * (E - D) + 3/a2
where,D = (1/Pie) COS-1 ((-1)/) =
#VALUE!
D =
& E = (1/Pie) COS-1 ((-2)/) =
E =

#VALUE!

#VALUE!
#VALUE!
%

Thus D' =

#VALUE!
Thus D' = #VALUE!
& percentage pressure at the upstream side key point D 1' = 100 - D' = #VALUE!
Uplift pressure at the point D1' = % pressure * max. static head
thus, uplift pressure at point D1' =
also Uplift pressure at D/S point D' =

#VALUE! #VALUE!
m.
#VALUE! #VALUE!
m.

75% of water head is considered.


( ii ) Exit Gradient :The exit gradient at the end is given by (0.84 / d) * pressure at the D/S key point, where
d = thickness of the depressed floor.
#VALUE!

#VALUE!

which is less than 0.2 and may be considered safe for ordinary conditions as the canal is lined.
The pressure distribution from upstream key point to the downstream key point is linear.
D1 '

D'
#VALUE!

#VALUE!

#VALUE!
( iii ) Floor Thickness :1 Thickness required at U/S end of depressed floor = uplift pressure at pt. D 1' / G - 1
#VALUE!
#VALUE!
m.
#VALUE!
2 4 m away from U/S end of depressed floor
The thickness required at 4m away from U/
So provide depth after 4m away from U/S

#VALUE! m
0.7 m

2.6 U/S & D/S Cut-off walls :( i ) U/S Cut-off wall :Depth of u/s cut-off wall shall be maximum of the following :
( a ) U/S FSD / 3 + 0.5 m.
1.84 / 3 + 0.5 =
1.113
( b ) As per USBR,
Depth of u/s cut-off = 0.69 U/S FSD
0.69 * 1.84 ^ 0.5 =
So provide depth of cutoff at U/S =

0.936
1.2

Provide depth of U/S cut-off 1.2 m.


( i ) D/S Cut-off wall :Depth of d/s cut-off wall shall be maximum of the following :
( a ) D/S FSD / 2 + 0.5 m.
1.79 / 2 + 0.5 =
1.395
( b ) As per USBR,
Depth of d/s cut-off = 0.69 D/S FSD
0.69 * 1.79 ^ 0.5 =
So provide depth of cutoff at D/S =

0.923
1.4

Provide depth of D/S cut-off 1.4 m.

Value Of Ef2 From Blench Curves

HL
0
0.3
0.5
0.7
1
1.5
2
2.5
3
3.5
4
4.5
5
5.5
6

q
0.3
Ef2
0.37
0.52
0.62
0.67
0.75
0.8
0.88
0.96
1
1
1.03
1.05
1.07
1.08
1.09

q
1
Ef2
0.6
0.78
0.9
0.97
1.08
1.15
1.27
1.3
1.36
1.43
1.48
1.5
1.5
1.5
1.5

q
2
Ef2
1.04
1.244
1.38
1.44
1.54
1.65
1.88
1.97
2
2.03
2.12
2.2
2.24
2.27
2.35

q
3
Ef2
1.45
1.63
1.75
1.85
2
2.2
2.35
2.4
2.48
2.52
2.58
2.74
2.78
2.85
2.9

q
4
Ef2
1.62
1.926
2.13
2.23
2.38
2.51
2.58
2.72
2.84
2.96
3.01
3.1
3.14
3.21
3.24

q
5
Ef2
2
2.282
2.47
2.53
2.63
2.84
3
3.1
3.25
3.32
3.39
3.48
3.51
3.61
3.65

q
6
Ef2
2.22
2.532
2.74
2.84
3
3.14
3.26
3.46
3.5
3.6
3.66
3.7
3.76
3.88
4

q
7
Ef2
2.5
2.8
3
3.11
3.28
3.45
3.56
3.72
3.76
3.94
4
4.08
4.14
4.24
4.38

#VALUE!
q
8
Ef2
2.75
3.05
3.25
3.35
3.5
3.64
3.86
4
4.1
4.2
4.38
4.45
4.5
4.55
4.64

0
0
50
35
26
22.5
19.7
17.4
13.2
11
9.8
8
7
6.5
5
4.1
4
3.8
3.7
2.7
2.5
2.1
1.8
1.5
1.3
1
0
0
0
0

0
0.05
0.06
0.07
0.08
0.09
0.1
0.11
0.12
0.13
0.14
0.15
0.16
0.17
0.18
0.19
0.2
0.21
0.22
0.23
0.24
0.25
0.26
0.27
0.28
0.29
0.3
0.31
0.32
0.33

QUANTITY OF Cross Regulator AT CH. 8983 FOR Pipali Distributory of LD-3B(VALLABHIPUR SUB BRANCH
CANAL)
Sl
Item of work
NOS L ( m ) B (m ) D ( m ) Total Qty
S-1 Excavation for foundation in all sorts of soil including sandy and gravelly
soils, soft murrum including depositing the excavated stuff as and where
directed including backfilling the trenches with suitable excavated stuff etc.
complete for lead upto 50 mt. and lift as under.

1.1 Lift 0.0 to 1.5m


(a) Section A-A :

depth =
1.5
Total Depth =
1.50
Length = 3 + 0.15*1 + crest width + (crest RL - cistern RL)*2
#VALUE!
Width = 2 * top width of bank + 2*outer slope*0.5*U/S FB +
2*berm + (U/S FSD + lined FB)*inner slope*2 + bed width
= 2*1.5 + 2*2*0.5*0.55 + 2*0.2 + (1.84+0.3)*1.5*2 + 1.15
1.2 Lift 1.5 to 3.0m
(a) Section A-A :
depth =
0
Total Depth =
0
1.3 Lift 3.0 to 4.5m
(a) Section A-A :
Balance D=
0
Total
S-3 Providing and laying cement concrete 1:2:4 (Nominal mix) of
cement,
sand
and
metal
in
foundation
including
centering,shuttering,transporting,mixing,placing,vibrating,smooth
finishing, curing etc.complete for all leads and lifts wherever
necessary for footing of barrel, pier, abutment, column, return wall,
chute wall, transition wall etc.

###

12.07

1.50

#VALUE!

###

12.07

0.00

#VALUE!

###

12.07

0.00

#VALUE!
#VALUE!

###

12.07

0.15

#VALUE!

C.C. ( 1 : 2 : 4 ) proportion ( O.P.C.) M15

(a) Section A-A :


Length = 3 + 0.15*1 + crest width + (crest RL - Cistern RL)*slope
#VALUE!
Total

#VALUE!

S-4 Providing and laying ordinary portland cement concrete M-15 grade
for R.C.C. curb, abutments, wing walls, and return walls, including
form work, scaffolding, rodding, vibrating, smooth finishing, curing
etc. complete for all leads and lifts.
Machinery based
(a) Section A-A : (Idealised Depressed floor)
Rectangle portion under cistern
Rectangle portion under the CBL
Rectangle portion under the Crest
Triangle portion between the Crest & CBL
Triangle portion at glacis
Triangle portion at D/S end

1
1
1
1
1
1
Total =

Qty. Page 9 of 17

###
12.07
12.07
12.07
12.07
12.07

12.07
3.15
1.20
0.15
###
###

###
###
###
0.15
###
###

#VALUE!
#VALUE!
#VALUE!
0.14
#VALUE!
#VALUE!
#VALUE!

Sl
Item of work
NOS L ( m )
S-5 Providing and laying reinforced cement concrete of M-20 grade,
using ordinary portland cement (OPC), sand and coarse aggregate
for piers, abutment, wing wall, well stening, raft, barrels, troughs,
footing of piers etc. including form work, batching, mixing, placing,
vibrating, curing, smooth finishing etc. complete for all leads and
lifts excluding cost of reinforcement.
Machinary based :(a) U/S Return wall (Section :4-4)
Trapezoidal portion
Rectangle portion (bottom)
(b) D/S Return wall (Section :5-5)
Trapezoidal portion
Rectangle portion (bottom)

B (m ) D ( m ) Total Qty

2
2

12.07
12.07

0.625
4.47

5.52
0.60

83.30
64.67

2
2

12.07
12.07

0.63
4.43

5.47
0.60

82.54
64.16
294.68

1
1
1
1
1
1

###
12.07
12.07
12.07
12.07
12.07

12.07
3.15
1.20
0.15
###
###

0.70
0.70
0.70
0.70
0.70
0.70

#VALUE!
26.61
10.14
0.63
#VALUE!
#VALUE!

3
4

12.07
12.07

0.80
0.15

5.40
0.15

156.43
0.54

3
4

12.07
12.07

0.80
0.15

2.39
0.15

69.23
0.54

2
2

12.07
12.07

0.45
0.15

###
0.15

#VALUE!
0.27
#VALUE!

Total
S-48 Providing and laying reinforced cement concrete of M-25 grade, using
ordinary portland cement (OPC), sand and coarse aggregate for piers,
abutment, wing wall, well stening, raft, barrels, troughs, footing of piers etc.
including form work, batching, mixing, placing, vibrating, curing, smooth
finishing etc. complete for all leads and lifts excluding cost of reinforcement.

Machinary based :(a) Section A-A : (Idealised Depressed floor)


Rectangle portion under cistern
Rectangle portion under the CBL
Rectangle portion under the Crest
Triangle portion between the Crest & CBL
Triangle portion at glacis
Triangle portion at D/S end
(b) Section 1-1:
Three rectangular vertical bays
150 mm. * 150 mm. Fillet
(c) Section 2-2:
Three rectangular vertical bays
150 mm. * 150 mm. Fillet
(d) Section 3-3:
Two rectangular vertical bays
150 mm. * 150 mm. Fillet
Total

Qty. Page 10 of 17

Sl
Item of work
NOS L ( m )
S-6 Providing and placing in position mild steel or high yield strength deformed

B (m ) D ( m ) Total Qty

(HYSD) steel reinforcement including cutting, bending, binding and welding


joints where necessary, hooking etc. complete as per drawing for all leads
and lifts.
(a) Section 1-1:
(b) Section 2-2:
(c) Section 3-3:
(d) Section 4-4:
(e) Section 5-5:
(f) Section 6-6:
(g) U/S transition wall (on both faces)
(h) D/S transition wall (on both faces)

2715.23
2258.92
5001.25
3538.00
3538.00
1591.20
1257.00
1257.00
21156.60

2
2

Total
S-14 Manufacture, supply of Vertical gate components including Embedded, gate
leaf and stationary parts of vertical gates consisting of wall plate, sill plate
and hoist anchor bolts for gate, steel platform, trunnion bracket and other
relevant components and accessories as per drawings including painting
with primer coat of colour as per drawing and specifications including
performance test.

2.00

S-50 Providing and fixing in position P.V.C. heavy duty water stops in barrels,
troughs and wing wall with 25 mm. wide expansion joint as shown in
drawing including filling the joints with asphalt pad or bitumen cork board of
approved quality.
(a) 225 mm. wide P.V.C. Water stop
(i) at starting of U/S & D/S transition wall
(ii) at end of U/S & D/S transition wall
(iii) at the junction of return wall and abutment
(iv) at the starting point of Cistern floor

2
2
4
1

Total
S-9 Providing and fixing in position canal data boards of standard size 1.0m x

7.97
12.17
3.21
4.60

15.94
24.34
12.84
4.60
57.72
1

1.0m with M.S. angle 40mm x 40mm x 6mm with 3mm thick iron plate in
1:5:10 proportion concrete block size 40cm x 40cm x 75cm Including
painting existing data on the board etc.complete as directed.

S-41 Providing and laying reinforced cement concrete of M-15 grade, lining by
using sulphate resisting portland cement by side slope, curvature and bed,
laid in panels including mixing, formwork placing, vibrating, curing as under
complete (Dewatering and providing and placing P.V.C. joints will be paid
seperatly in respective item.)

(Machinery based)
( a ) U/S Transition wall
200 mm. th. Lining
Cut-off wall
( b ) D/S Transition wall
200 mm. th. Lining
Cut-off wall
Total

Qty. Page 11 of 17

1
1

4.70
0.30

12.07
12.07

56.73
3.62

1
1

4.70
0.30

12.07
12.07

56.73
3.62
120.70

Estimate OF Cross Regulator AT CH. 8983 FOR Pipali Distributory of LD-3B(VALLABHIPUR SUB BRANCH
CANAL)
Sl No.

Item of work

Unit

Qty

Rate (Rs.)

Amount (Rs.)

Cum
Cum
Cum

#VALUE!
#VALUE!
#VALUE!

31.40
31.85
33.60

#VALUE!
#VALUE!
#VALUE!

1600.05

#VALUE!

S-1 Excavation for foundation in all sorts of soil including sandy and
gravelly soils, soft murrum including depositing the excavated stuff as
and where directed including backfilling the trenches with suitable
excavated stuff etc. complete for lead upto 50 mt. and lift as under.
(A) Lift 0.0 to 1.5 mt. Depth.
(B) Lift 1.5 to 3.0 mt. Depth.
(C) Lift 3.0 to 4.5 mt. Depth.
(SOR Item No. S-1,Pg No.-36 Yr 2004-2005)
S-3 Providing and laying cement concrete 1:2:4 (Nominal mix) of cement,
sand
and
metal
in
foundation
including
centering,
shuttering,transporting,mixing,placing,vibrating,smooth
finishing,
curing etc.complete for all leads and lifts wherever necessary for
footing of barrel, pier, abutment, column, return wall, chute fall,
transition wall etc.
As Per Rate Analysis
S-4 Providing and laying ordinary portland cement concrete M-15

Cum

#VALUE!

Cum

#VALUE!

1933.00

#VALUE!

Cum

294.68

2262.85

666809.80

Cum

#VALUE!

2374.05

#VALUE!

MT

21.16

27619.10

584326.14

No.

2.00

20000.00

40000.00

grade for R.C.C. curb, abutments, wing walls, and return walls,
including form work, scaffolding, rodding, vibrating, smooth
finishing, curing etc. complete for all leads and lifts.
(SOR Item No. S-27(b),Pg No.-45 Yr 2004-2005)
S-5 Providing and laying reinforced cement concrete of M-20

grade, using ordinary portland cement (OPC), sand and coarse


aggregate for piers, abutment, wing wall, well stening, raft,
barrels, troughs, footing of piers etc. including form work,
batching, mixing, placing, vibrating, curing, smooth finishing
etc. complete for all leads and lifts excluding cost of
reinforcement.
(SOR Item No. S-93(i),Pg No.-65 Yr 2004-2005)
S-48 Providing and laying reinforced cement concrete of M-25 grade, using
ordinary portland cement (OPC), sand and coarse aggregate for piers,
abutment, wing wall, well stening, raft, barrels, troughs, footing of piers
etc. including form work, batching, mixing, placing, vibrating, curing,
smooth finishing etc. complete for all leads and lifts excluding cost of
reinforcement.
(SOR Item No. S-93(ii),Pg No.-65 Yr 2004-2005)
S-6 Providing and placing in position mild steel or high yield strength
deformed (HYSD) steel reinforcement including cutting, bending,
binding and welding joints where necessary, hooking etc. complete as
per drawing for all leads and lifts.
(SOR Item No. S-70,Pg No.-57 Yr 2004-2005)

S-14 Manufacture, supply of Vertical gate components including Embedded,


gate leaf and stationary parts of vertical gates consisting of wall plate,
sill plate and hoist anchor bolts for gate, steel platform, trunnion
bracket and other relevant components and accessories as per
drawings including painting with primer coat of colour as per drawing
and specifications including performance test.

Note ;As Gate Item is not available in VSBC SOR, rate has
been taken from KBC SOR O-1 (17),Page-94,Year 2001-2002

Sl No.

Item of work

Unit

S-50 Providing and fixing in position P.V.C. heavy duty water stops in
barrels, troughs and wing wall with 25 mm. wide expansion joint as
shown in drawing including filling the joints with asphalt pad or bitumen
cork board of approved quality.
Metre
(SOR Item No. S-75,Pg No.-58 Yr 2004-2005)
S-9 Providing and fixing in position canal data boards of standard size
1.0m x 1.0m with M.S. angle 40mm x 40mm x 6mm with 3mm thick
iron plate in 1:5:10 proportion concrete block size 40cm x 40cm x
75cm Including painting existing data on the board etc.complete as
directed.
(SOR Item No. E30,Pg No.-11 Yr 2004-2005)

Qty

Rate (Rs.)

Amount (Rs.)

57.72

246.30

14216.44

No.

1.00

1449.50

1449.50

M2

120.70

352.20

42510.54

S-41 Providing and laying reinforced cement concrete of M-15 grade, lining
by using sulphate resisting portland cement by side slope, curvature
and bed, laid in panels including mixing, formwork placing, vibrating,
curing as under complete (Dewatering and providing and placing
P.V.C. joints will be paid seperatly in respective item.)

(SOR Item No. S-84,Pg No.-62 Yr 2004-2005)


Total=
Add 1% for quality control=
Sub Total=
Add 1% for conti. Charges=

Grand Total =
Say Rs.=

#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!
#VALUE!

#VALUE!
Deputy Executive Engineer
SBC Sub Division No. 2/2 - C
Dhandhuka

Executive Engineer
SBC Division No. 2/2
Dhandhuka

Sl No.

Item of work

Unit

Qty

Rate (Rs.)

RATE ANALYSIS-No-1
CONSTRUCTION OF VARIOUS STRUCTURES ON SUB MINORS OF MITHIGARIYAL MINOR-I
Item No. S- Excavation for foundation in all sorts of soil including sandy & gravelly soils, soft murrum
1
and Hard murrum including depositing the excavated stuff as directed including backfilling
the trenches with suitable excavated stuff etc. complete for lead up to

(A): Excavation for foundation in all sorts of soil including sandy & gravelly soils, soft murrum
including depositing the excavated stuff as directed including backfilling the trenches with
suitable excavated stuff etc. complete for lead up to 50 m & all lift
(SOR Item No. S1,Pg No.-36 Yr 2003-2004)
Sr. No.
1
(a)
(b)
(c)

Depth

Unit

2
Lift 0 to 1.5 m Depth
Lift 1.5 to 3.0 m Depth
Lift 3 to 4.5 m Depth

3
cum
cum
cum
Total

Rate (Rs.)

Qty.
(cum)
4
###
0.00
0.00
###

5
31.40
31.85
33.60

Amount
(Rs.)
6
#VALUE!
0
0
#VALUE!

(B) Excavation for foundation in hard murrum including depositing the excavated stuff as and
where directed including back filling the trenches with the excavated stuff etc. complete for
leads up to 50m and all lifts.
(SOR Item No. S2,Pg No.-36 Yr 2003-2004)
Sr. No.
1

Depth

2
(a) Lift 0 to 1.5 m Depth
(b) Lift 1.5 to 3.0 m Depth
(c) Lift 3 to 4.5 m Depth

Unit
3
cum
cum
cum
Total

Qty.
(cum)
4
0.00
0.00
0.00
0.00

Rate (Rs.) Amount


5
34.75
35.25
37.17

(Rs.)
6
0
0.00
0
0.00

Average waitage rate= #VALUE!

Deputy Executive Engineer


SBC Sub Division No. 2/2 - C
Dhandhuka

Executive Engineer
SBC Division No. 2/2
Dhandhuka

Amount (Rs.)

1.0 HYDRAULIC AND STRUCTURAL DESIGN


OF
CROSS-REGULATOR AT CH-8983
OF PIPLI DISTRIBUTARY (LD-3B)
OFFTAKING FROM 63625 m. OF
VALLABHIPUR SUB BRANCH CANAL

4.0 QUANTITY ESTIMATION


OF
CROSS-REGULATOR FOR PIPLI DISTRIBUTORY
OF LD-3B OFFTAKING FROM 63625 m.
AT
CHAINAGE 8983 m.
FOR
VALLABHIPUR SUB BRANCH CANAL

5.0 COST ESTIMATION


OF
CROSS-REGULATOR FOR PIPLI DISTRIBUTORY
OF LD-3B OFFTAKING FROM 63625 m.
AT
CHAINAGE 8983 m.
FOR
VALLABHIPUR SUB BRANCH CANAL

You might also like