You are on page 1of 6

ComFlor 60/0.

9/S350

SCI
JOB REFERENCE:
DECK REFERENCE:
COMPANY NAME:
CLIENT NAME:
FILENAME:

BS 5950 Parts 4, 6 and 8

Page 1 of 6

Tata Steel
CF60/0.9_350
Calcs by:

v9.0.29.0
5/11/2016
11:02:17

Date:
Time:
Job No.:
Checked by:

FULL OUTPUT
NOTE: SECTION DESIGNED TO BRITISH STANDARDS
Construction Stage:
PASS
Max Unity Factor = 0.67
Normal Stage:
PASS
Max Unity Factor = 0.30
Fire Condition:
PASS
Max Unity Factor = 0.55
Serviceability:
SATISFACTORY
Max Unity Factor = 0.47
*** SECTION ADEQUATE ***
FLOOR PLAN DATA : (unpropped composite construction with ComFlor 60/0.9/S350 decking)
Beam centres - equal
2.80 m
Span type
DOUBLE
Beam or wall width
152 mm
Propping
NONE
PROFILE DATA : (ComFlor 60/0.9/S350 decking)
Depth
60 mm
Trough width
120 mm
Nominal sheet thickness
0.90 mm
Deck weight
0.10 kN/m

Pitch of deck ribs


Crest width
Design sheet thickness
Yield strength

CONCRETE SLAB : [Normal Weight Concrete ; Mesh : A193]


Overall slab depth
130 mm
Concrete characteristic strength 40 N/mm
Concrete wet density
Modular ratio
10
Concrete dry density
Bar reinforcement
NONE
Mesh reinforcement :

Mesh
Cover to Mesh
Account for End Anchorage
Diameter of Shear Connectors
Screed depth

A193
30 mm
NO
N/A
100 mm

300 mm
130.7 mm
0.86 mm
350 N/mm
2400 kg/m
2350 kg/m

Yield strength
Mesh Layers
Shear connectors per rib

460 N/mm
Single
N/A

Screed density

2200 kg/m

SECTION PROPERTIES :
***NOTE - 1: All values of inertia are expressed in steel units
***NOTE - 2: Average inertia is used for deflection calculations for the composite stage
***NOTE - 3: Cracked dynamic inertia is used for natural frequency calculations

DECK PROFILE:

Sagging Inertia, Ixx


Hogging Inertia, Iyy

File Name:

92.770 cm4/m
86.130 cm4/m

Area of profile (Net), Ap

1276 mm/m

v9.0.29.0

ComFlor 60/0.9/S350

BS 5950 Parts 4, 6 and 8

Page 2 of 6

COMPOSITE:
Inertia, Ixx - Uncracked

1492 cm4/m

Cracked

709 cm4/m

Average inertia

1100 cm4/m

Cracked inertia (dynamic)

802 cm4/m

Shear bond coefficients - Mr

208.86

Kr

0.014700

Concrete volume

0.098 m/m/m

LOADS ACTING ON SLAB :


*** NOTE: Slab subjected to uniformly distributed loads (UDL) ONLY
Imposed (occupancy)

1.50 kN/m

Partitions

Ceilings and services

0.60 kN/m

Finishes

0.00 kN/m
1.10 kN/m

Self weight of concrete slab (wet)

2.31 kN/m

Self weight of decking

0.10 kN/m

Self weight of concrete slab (dry)

2.27 kN/m

Self weight of screeds

2.16 kN/m

Construction load

1.6 kN/m

Fire resistance period

60 mins

LINE LOADS PERPENDICULAR TO DECK SPAN :


None

LINE LOADS PARALLEL TO DECK SPAN :


None

FIRE DATA :
Design method

SIMPLE

Non-permanent imposed loads

0.0 kN/m

PARTIAL SAFETY FACTORS :


Dead (self weight)

1.40

Imposed

1.60

Super imposed dead

1.40

Fire (occupancy loads)

0.80

File Name:

v9.0.29.0

ComFlor 60/0.9/S350

BS 5950 Parts 4, 6 and 8

Page 3 of 6

CONSTRUCTION STAGE
LOADINGS

Self weight of decking


Self weight of concrete slab (wet)
Construction load (one span)
Construction load (adjacent span(s))
Total factored load (maximum)

Unfactored(kN/m)

0.10
2.31
1.61
0.54
= 0.14 + 3.24 + 0.00 + 2.57
= 5.96 kN/m

Factored(kN/m)

0.14
3.24
2.57
0.86

EFFECTIVE SPAN OF DECK :

Effective span Le, is the smaller of


1) c/c of supports
2) clear span + deck depth
Therefore Le

= 2.80 m
= 2.65 + 60.0 / 1000
= 2.71 m
= 2.71 m

SHEAR RESISTANCE CHECK :

*** Check at first interior support position


Applied shear
Shear strength of decking, pv
Shear resistance, Pv
UNITY FACTOR

= 8.63 kNm/m
= 157.2 N/mm
= 54.1 kN/m
= 0.16

PASS

17.26 kN/m
40.65 kN/m
= 0.42

PASS

WEB CRUSHING RESISTANCE CHECK :

*** Check at first interior support position


Applied reaction
Web crushing resistance, Pw
UNITY FACTOR
BENDING RESISTANCE CHECK :

NOTE: *** a 30% redistribution of hogging moment is taken based on equilibrium of the continuous decking as the sagging moment
does not exceed the design resistance
SAGGING:

Max applied moment


Moment resistance, Mc
UNITY FACTOR

HOGGING:

Max. applied moment


Moment resistance, Mc
UNITY FACTOR

= 5.04 kNm/m
= 9.30 kNm/m
= 0.54

PASS

= 3.27 kNm/m
= 7.50 kNm/m
= 0.44

PASS

INTERACTION OF BENDING MOMENT AND SHEAR :

NOTE 1: *** Check at first interior support position


NOTE 2: *** a 30% redistribution of hogging moment is taken based on equilibrium of the continuous decking as the sagging moment
does not exceed the design resistance
Applied shear
= 8.11 kN/m
Shear resistance, Pv
= 54.09 kN/m
Applied moment
= 3.27 kNm/m
Moment resistance, Mc
= 7.50 kNm/m
UNITY FACTOR
= [8.11/54.09]^2 + [3.27/7.50]^2
= 0.21
PASS

File Name:

v9.0.29.0

ComFlor 60/0.9/S350

BS 5950 Parts 4, 6 and 8

Page 4 of 6

INTERACTION OF BENDING MOMENT AND WEB CRUSHING :

NOTE 1: *** Check at first interior support position


NOTE 2: *** a 30% redistribution of hogging moment is taken based on equilibrium of the continuous decking as the sagging moment
does not exceed the design resistance
Applied reaction
= 16.22 kN/m
Web crushing resistance, Pw
= 40.65 kN/m
Applied moment
= 3.27 kNm/m
Moment resistance, Mc
= 7.50 kNm/m
UNITY FACTOR
= [16.22/40.65 + 3.27/7.50]
= 0.84 < 1.25
PASS
DEFLECTION CHECK :

Allowable deflection max, is the lesser of


1) Effective span/180 (= 15.0 mm ), and
2) 20 mm ( absolute maximum value ), and
3) Slab depth/10 = ( 13.0 mm )
Max. self weight deflection

= 4.05 mm
( < 13.00 mm )
***NOTE: Deflection within code limits; ponding is not considered
SERVICEABILITY STRESS CHECK :

Stress for sagging moment


Stress for hogging moment
UF for sagging moment
UF for hogging moment

File Name:

= 47.92
= 97.28
= 0.14
= 0.28

SATISFACTORY

PASS
PASS

v9.0.29.0

ComFlor 60/0.9/S350

BS 5950 Parts 4, 6 and 8

Page 5 of 6

NORMAL STAGE
LOADINGS : (see construction load calculations for details):

Dead
Imposed
Superimposed dead
Total

Unfactored (kN/m)
0.10 + 2.27
= 2.37
1.50 + 0.00
= 1.50
0.60 + 1.10 + 2.16
= 3.86
= 7.73 kN/m

Factored (kN/m)
3.32
2.40
5.40
11.12 kN/m

EFFECTIVE SPAN :

Effective span Le, is the smaller of


1) c/c of supports
2) clear span + slab overall depth - depth to centroid = 2.65 + 130 / 1000 - 33.7 / 1000
= 2.74 m
Therefore Le
= 2.74 m

SHEAR RESISTANCE CHECK :

Maximum applied shear

Shear stress in concrete, v


Shear strength of concrete, vc
Shear resistance
UNITY FACTOR

= 0.5 * 11.12 * 2.74


= 15.26 kN/m
= 0.33 N/mm
= 1.16 N/mm
= 144.65 * 96.30 * 1.16 / 300.00
= 53.82 kN/m
= 0.28

PASS

= 2.74 / 4
= 0.69 m
= 10.70 kN/m
= 37.09 kN/m
= 0 kN/m
= (37090.08/1000) + [(0/1000)]/2 = 37.09 kN/m
= 0.29

PASS

PUNCHING SHEAR CHECK :

Not Applicable

SHEAR BOND RESISTANCE CHECK :

Shear span

Applied shear
Shear bond resistance
Anchorage resistance
Total shear resistance
UNITY FACTOR
BENDING RESISTANCE CHECK :

Applied bending moment

= 0.125 * 11.12 * 2.74^2


= 10.51 kNm/m
Depth of concrete stress block
= 23.07 mm
NOTE: depth of concrete in compression may be limited to 0.45 ds
Tension in decking
= 415.34 kN/m
Tension in bar reinforcement
= 0.00 kN/m
Depth to position of resultant tension
= (0.0 * 100.0 + 415.3 * 96.3) / (0.0 + 415.3)
= 96.30 mm
Lever arm
= 84.77 mm
NOTE: lever arm may be limited to 0.95 ds
Compression in concrete
= 415.34 kN/m
Moment resistance
= 415.34 * 84.77/1000
= 35.21 kNm/m
UNITY FACTOR
= 0.30

File Name:

PASS

v9.0.29.0

ComFlor 60/0.9/S350

BS 5950 Parts 4, 6 and 8

Page 6 of 6

FIRE RESISTANCE CHECK :


Effective span in fire, is the greater of
1) c/c suppports - support width

= 2.80 - 152 / 1000


= 2.65 m
2) c/c supports - 150
= 2.80 - 150 / 1000
= 2.65 m
i.e effective span in fire
= 2.65 m
Fire dead load
= 0.10 + 2.27 + 0.60 + 1.10 + 2.16
= 6.34 kN/m
Non-permanent fire imposed load
= 0.80 * 0.0 *1.50
= 0.0 kN/m
Permanent fire imposed load
= (1 - 0.0) *1.50 + 0.00
= 1.50 kN/m
Fire imposed load
= 0.00 + 1.50
= 1.50 kN/m
Fire free moment
= 6.88 kNm/m
Moment resistance, sagging
= 8.13 kNm/m
Moment resistance, hogging
= 9.97 kNm/m
Moment resistance, Mr
= 8.13 + 0.45 * 9.97 *** for end span
= 12.63 kNm/m
UNITY FACTOR
= 0.55
As spans are approximately equal, no check on uplift at an external support has been made

DEFLECTION CHECK :
Allowable deflection max-i under imposed loads, is the lesser of
1) Effective span/350 (= 7.8 mm ), and
2) Absolute maximum value (mm) = 20
Imposed load deflection
Allowable total deflection max-t, is the lesser of
1) Effective span/250 or 11.0 mm, and
2) 30 mm ( SCI recommended absolute maximum value )
Deflection due to imposed loads
Additional deflection due to superimposed dead loads
Total deflection

PASS

= 0.013 * 2.60 * (2.74* 1000 )^4 / (205*11004900 )/1000


= 0.5 mm ( < 7.8 mm )
SATISFACTORY

= 0.5 mm (based on average inertia)


= 1.3 mm (based on average inertia)
= 0.5 + 1.3
= 1.8 mm ( < 11.0 mm )

SATISFACTORY

DYNAMIC SENSITIVITY :
*** NOTE: loads are dead + super-imposed dead + 10% imposed

Dynamic inertia (cracked section)


Maximum deflection
Frequency

File Name:

= 802 cm4
= 0.013 * 6.38 * (2.74* 1000 )^4 / (205*8022758 )/1000
= 2.88 mm
= 18 / 2.88 )
= 10.61 Hz ( > 5.00 Hz)
SATISFACTORY

v9.0.29.0