Professional Documents
Culture Documents
9/S350
SCI
JOB REFERENCE:
DECK REFERENCE:
COMPANY NAME:
CLIENT NAME:
FILENAME:
Page 1 of 6
Tata Steel
CF60/0.9_350
Calcs by:
v9.0.29.0
5/11/2016
11:02:17
Date:
Time:
Job No.:
Checked by:
FULL OUTPUT
NOTE: SECTION DESIGNED TO BRITISH STANDARDS
Construction Stage:
PASS
Max Unity Factor = 0.67
Normal Stage:
PASS
Max Unity Factor = 0.30
Fire Condition:
PASS
Max Unity Factor = 0.55
Serviceability:
SATISFACTORY
Max Unity Factor = 0.47
*** SECTION ADEQUATE ***
FLOOR PLAN DATA : (unpropped composite construction with ComFlor 60/0.9/S350 decking)
Beam centres - equal
2.80 m
Span type
DOUBLE
Beam or wall width
152 mm
Propping
NONE
PROFILE DATA : (ComFlor 60/0.9/S350 decking)
Depth
60 mm
Trough width
120 mm
Nominal sheet thickness
0.90 mm
Deck weight
0.10 kN/m
Mesh
Cover to Mesh
Account for End Anchorage
Diameter of Shear Connectors
Screed depth
A193
30 mm
NO
N/A
100 mm
300 mm
130.7 mm
0.86 mm
350 N/mm
2400 kg/m
2350 kg/m
Yield strength
Mesh Layers
Shear connectors per rib
460 N/mm
Single
N/A
Screed density
2200 kg/m
SECTION PROPERTIES :
***NOTE - 1: All values of inertia are expressed in steel units
***NOTE - 2: Average inertia is used for deflection calculations for the composite stage
***NOTE - 3: Cracked dynamic inertia is used for natural frequency calculations
DECK PROFILE:
File Name:
92.770 cm4/m
86.130 cm4/m
1276 mm/m
v9.0.29.0
ComFlor 60/0.9/S350
Page 2 of 6
COMPOSITE:
Inertia, Ixx - Uncracked
1492 cm4/m
Cracked
709 cm4/m
Average inertia
1100 cm4/m
802 cm4/m
208.86
Kr
0.014700
Concrete volume
0.098 m/m/m
1.50 kN/m
Partitions
0.60 kN/m
Finishes
0.00 kN/m
1.10 kN/m
2.31 kN/m
0.10 kN/m
2.27 kN/m
2.16 kN/m
Construction load
1.6 kN/m
60 mins
FIRE DATA :
Design method
SIMPLE
0.0 kN/m
1.40
Imposed
1.60
1.40
0.80
File Name:
v9.0.29.0
ComFlor 60/0.9/S350
Page 3 of 6
CONSTRUCTION STAGE
LOADINGS
Unfactored(kN/m)
0.10
2.31
1.61
0.54
= 0.14 + 3.24 + 0.00 + 2.57
= 5.96 kN/m
Factored(kN/m)
0.14
3.24
2.57
0.86
= 2.80 m
= 2.65 + 60.0 / 1000
= 2.71 m
= 2.71 m
= 8.63 kNm/m
= 157.2 N/mm
= 54.1 kN/m
= 0.16
PASS
17.26 kN/m
40.65 kN/m
= 0.42
PASS
NOTE: *** a 30% redistribution of hogging moment is taken based on equilibrium of the continuous decking as the sagging moment
does not exceed the design resistance
SAGGING:
HOGGING:
= 5.04 kNm/m
= 9.30 kNm/m
= 0.54
PASS
= 3.27 kNm/m
= 7.50 kNm/m
= 0.44
PASS
File Name:
v9.0.29.0
ComFlor 60/0.9/S350
Page 4 of 6
= 4.05 mm
( < 13.00 mm )
***NOTE: Deflection within code limits; ponding is not considered
SERVICEABILITY STRESS CHECK :
File Name:
= 47.92
= 97.28
= 0.14
= 0.28
SATISFACTORY
PASS
PASS
v9.0.29.0
ComFlor 60/0.9/S350
Page 5 of 6
NORMAL STAGE
LOADINGS : (see construction load calculations for details):
Dead
Imposed
Superimposed dead
Total
Unfactored (kN/m)
0.10 + 2.27
= 2.37
1.50 + 0.00
= 1.50
0.60 + 1.10 + 2.16
= 3.86
= 7.73 kN/m
Factored (kN/m)
3.32
2.40
5.40
11.12 kN/m
EFFECTIVE SPAN :
PASS
= 2.74 / 4
= 0.69 m
= 10.70 kN/m
= 37.09 kN/m
= 0 kN/m
= (37090.08/1000) + [(0/1000)]/2 = 37.09 kN/m
= 0.29
PASS
Not Applicable
Shear span
Applied shear
Shear bond resistance
Anchorage resistance
Total shear resistance
UNITY FACTOR
BENDING RESISTANCE CHECK :
File Name:
PASS
v9.0.29.0
ComFlor 60/0.9/S350
Page 6 of 6
DEFLECTION CHECK :
Allowable deflection max-i under imposed loads, is the lesser of
1) Effective span/350 (= 7.8 mm ), and
2) Absolute maximum value (mm) = 20
Imposed load deflection
Allowable total deflection max-t, is the lesser of
1) Effective span/250 or 11.0 mm, and
2) 30 mm ( SCI recommended absolute maximum value )
Deflection due to imposed loads
Additional deflection due to superimposed dead loads
Total deflection
PASS
SATISFACTORY
DYNAMIC SENSITIVITY :
*** NOTE: loads are dead + super-imposed dead + 10% imposed
File Name:
= 802 cm4
= 0.013 * 6.38 * (2.74* 1000 )^4 / (205*8022758 )/1000
= 2.88 mm
= 18 / 2.88 )
= 10.61 Hz ( > 5.00 Hz)
SATISFACTORY
v9.0.29.0