AP 1120

Siemens

AP 1120

Contents
1
1.1
1.2
1.3
1.4

AP 1120. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Feature description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Indicators and connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
AMO usage in the HiPath 4000 V2.0. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Settings in the AP 1120 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
1.4.1
Checking the loaded AP 1120 software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
1.4.1.1 With DHCP resp. known IP-Address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
1.4.1.2 Without DHCP for the first installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
1.4.2
Preparation for Loading AP 1120 Software (Flashing) . . . . . . . . . . . . . . . . . 12
1.4.2.1 Loading with DHCP function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
1.4.2.2 Loading the AP without DHCP function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
1.4.3
Settings of the HiPath 4000 V2.0 data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
1.4.4
General actions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41

EN0000DE00EN_0000
2005 Siemens AG

Siemens

AP 1120

EN0000DE00EN_0000
2005 Siemens AG

AP 1120

Siemens

AP 1120

1.1

Feature description

The AP 1120 supports the connection of Group 3 Fax devices, analog Modems and voice terminals via IP. The installation is done via the board STMI2 (Q2316-X / - X10) as HG3530 (FCTID=3) in the HiPath 4000 V2.0. It is also possible to use the AP 1120 on a HiPath 3000 with
H323v3 and SIP. In the HiPath 4000 V2.0 the Codec G.711 is supported. The AP 1120 is administered with the Tool Unit Management Network (UMN). All settings, which are necessary for the HiPath 4000 V2.0, and Software-Updates have to be done by this UMN-Tool.

1.2

Indicators and connectors

Ready
(green)

In Use
(orange)

LAN
(green)

Power
(green)

Ready: Is ON, if the AP 1120 is registered at the HG3550 (PABX-Address and Subscriber number must be set).
In Use: Is ON, if one of the two device ports are busy (Port 1 or/and Port 2).
LAN: Is ON (or blinking), if there is a connection to the IP network (Layer 1).
Power: Is ON, if the AP 1120 is supplied by the power-supply.

EN0000DE00EN_0000
2005 Siemens AG

AP 1120

Siemens

Analog connectors Default setting


(Port 1 left, Port 2 Button
right)

Computer

Network

Power
nector

con-

Analog connector: G3 Fax devices resp. analog Modems can be connected.


Default
Setting
Button
Pressed for:

Action

Comments

LEDs

Pattern

Ready

In Use

LAN

Power

Off

Off

Off

Blink

2 to 5
seconds

AP 1120
reboot

No changes are
made to the AP
1120 settings.

5 to 10
seconds

AP 1120
reboot in
Recovery
Mode

Sets the AP 1120 Blink


IP address to its
default value in the
MIB and restarts
the unit.

Blink

Blink

Blink

10 to 15
seconds

AP 1120
reboot in
Factory Reset Mode

Deletes the persis- On


tent MIB values,
creates a new configuration file with
the default factory
values, then restarts the unit.

On

On

On

EN0000DE00EN_0000
2005 Siemens AG

AP 1120

Siemens

Computer: A 10/100 BaseT Ethernet RJ-45 connector that can be connected into the network card of a computer. In this case, the HiPath AP1120 acts as a small Ethernet switch. It is possible to use either a cross-over or straight Ethernet cable to
connect in the Computer connector. The Computer connector performs automatic MDI / MDIX detection, meaning that it adapts to the type of cable connected
to it.
Network: A 10/100 BaseT Ethernet RJ-45 connector for access to a LAN, WAN or computer. It can also be used as remote power feeding and is IEEE 802.3af compliant
and Power DSine certified. It is possible to use either a cross-over or straight
Ethernet cable to connect in the Network connector. The Network connector performs automatic MDI / MDIX detection, meaning that it adapts to the type of cable
connected to it.

1.3

AMO usage in the HiPath 4000 V2.0


Check resp. add the number of HG3530- boards
DISPLAY-DIMSU:TYPE=SYSTEM;
ADD-DIMSU:TYPE=SYSTEM,STMIHFA2=10;

Add the STMIHFA2 board


ADD-BCSU:MTYPE=PER,LTU=1,SLOT=6,PARTNO=Q2316-X,FCTID=3;

Set the STMIHFA2 board data


ADD-HFAB:MTYPE=STMIHFA2,LTU=1,SLOT=6,SMODE=NORMAL,IPADDR=1.30.11.40,
NETMASK=255.255.255.0;

Add subscriber G3-Fax / Voice terminal / Modem


ADD-COSSU:NEWCOS=41,INFO="41 NON VOICE DEVICE";
CHANGE-COSSU:TYPE=COS,COS=41,
AVCE=TA&TNOTCR&CDRSTN&CDRINT&RKOABS&COSXCD&TTT;
CHANGE-COSSU:TYPE=COS,COS=41,AFAX=TA&TNOTCR&BASIC&MSN&MULTRA;
CHANGE-COSSU:TYPE=COS,COS=41,ADTE=TA&TNOTCR&BASIC&MSN&MULTRA;
ADD-SBCSU:STNO=2425,OPT=OPTI,CONN=IP2,PEN=1-1-6-10,DVCFIG=OPTIIP&ANAFAX
or ANADTE,COS1=41,COS2=41,LCOSV1=11,LCOSV2=11,LCOSD1=11,LCOSD2=11,
DPLN=0,ITR=0,SSTNO=N,SPDI=0,SECR=N,INS=Y,ALARMNO=8,CALLOG=NONE;
ANAFAX for G3 Fax device or Voice terminal
ANADTE for Modem

EN0000DE00EN_0000
2005 Siemens AG

AP 1120

Siemens

1.4

Settings in the AP 1120

1.4.1

Checking the loaded AP 1120 software


The AP 1120 must be loaded with the CorNet-IP software. If the AP 1120 is not loaded with the right software, a flash action is necessary (see Loading AP 1120 Software (Flashing)). For flashing an AP1120 the Tool UMN and a TFTP software is
necessary on the Admin-PC.

Start Unit Management Network (UMN) and connect with the Unit Manager.

Password:
8749H323

1.4.1.1

With DHCP resp. known IP-Address

Device scanning

EN0000DE00EN_0000
2005 Siemens AG

AP 1120

Siemens

Enter IP-Address range and start the scan


operation.

Select AP 1120

EN0000DE00EN_0000
2005 Siemens AG

AP 1120

Siemens

Select the AP 1120 and check the loaded software.

1.4.1.2

Without DHCP for the first installation

The Default IP-Address of the AP 1120 is 192.168.0.1.

Connect the AP 1120 with the Admin-PC


Connect the AP 1120, Port COMPUTER, with the Admin-PC directly (straight or crossed
over cable can be used). Change the IP-Address of your PC, e.g. to 192.168.0.20 with Subnet-Maske 255.255.255.0.

EN0000DE00EN_0000
2005 Siemens AG

AP 1120

Siemens

Set the AP 1120 IP-Address to Default


Start a Reboot in Recovery Mode . To do this, press and hold the Default Setting
Button between 5 and 10 seconds, until all LEDs start blinking.

Device scanning

EN0000DE00EN_0000
2005 Siemens AG

AP 1120

Siemens

Enter
IP-Address
192.168.0.1 and start
scan operation.

Select AP 1120

10

EN0000DE00EN_0000
2005 Siemens AG

AP 1120

Siemens

Select AP 1120 and check the loaded Software.

EN0000DE00EN_0000
2005 Siemens AG

11

AP 1120

Siemens

1.4.2

Preparation for Loading AP 1120 Software (Flashing)

The Tool Unit Management Network (UMN) must be installed on the Admin-PC.
The directory-/file-structure of the TFTP-Server (PC):

If an AP 1120 is changed from H323 resp. SIP to CorNet-IP the loaded software
(H323 / SIP) is downloaded again before the CorNet-IP-Software can be transfered.
If it is an Upgrade of a CorNet-IP version to a newer one the download of the same
software is not necessary. After a Software change from H323/SIP to CorNet-IP a
Factory Reset must be executed !!!

Only an AP 1120 with Software H323 v4 can be migrated to CorNet-IP v1 !!!

12

EN0000DE00EN_0000
2005 Siemens AG

AP 1120

1.4.2.1

Siemens

Loading with DHCP function

Start Unit Management Network (UMN) and connect with the Unit Manager.

Password:
8749H323

Device scanning

EN0000DE00EN_0000
2005 Siemens AG

13

AP 1120

Siemens

Enter IP-Address range and start the scan


operation.

Control the scanning


time for the single IPAddresses.

Select AP 1120

14

EN0000DE00EN_0000
2005 Siemens AG

AP 1120

Siemens

Configure the Software Download Server

Right mouse key

EN0000DE00EN_0000
2005 Siemens AG

15

Siemens

AP 1120

The IP-Address of the


TFTP-Servers (PC):
1.30.21.2

Enter the directory of


the new Software.

16

EN0000DE00EN_0000
2005 Siemens AG

AP 1120

Siemens

Start the TFTP-Server (in this example: 3cDaemon)

Configure the TFTPServer

EN0000DE00EN_0000
2005 Siemens AG

17

AP 1120

Siemens

Start Software Download


Process: Click with the right mouse key on the AP and select Download Software
(Abrupt);

Select AP

18

EN0000DE00EN_0000
2005 Siemens AG

AP 1120

Siemens

The Software is transfered to the AP 1120

EN0000DE00EN_0000
2005 Siemens AG

19

Siemens

AP 1120

Display the status of the Download-process

Right mouse key;


selectEdit SNMP;

If there was a Software change from H323/SIP to CorNet-IP, a Factory Reset has
to be started (see Indicators and connectors) !!!

20

EN0000DE00EN_0000
2005 Siemens AG

AP 1120

Siemens

Delete the AP 1120 from the Unit Manager

Scan the AP 1120 again

Start device scanning

Enter IP address range and start the scan


operation.

Select the AP 1120

EN0000DE00EN_0000
2005 Siemens AG

21

AP 1120

Siemens

Check the Software version


Select the AP 1120 and check the loaded Software.

22

EN0000DE00EN_0000
2005 Siemens AG

AP 1120

Siemens

0.0.0.1

Loading the AP without DHCP function


The default IP-Address of the AP 1120 is 192.168.0.1.

Connect the AP 1120 with the Admin-PC


Connect the AP1120 with the Admin-PC directly (straight or crossed over cable is possible). Change the IP-Address of the Admin-PC, e.g. to 192.168.0.20 with Subnet mask
255.255.255.0.

Set the AP 1120 IP-Address to Default


Start a Reboot in Recovery Mode. To do this, press the Default Setting Button
between 5 to10 seconds, until all LEDs start to blink.

Start the Unit Management Network (UMN) and connect to the Unit Manager.

Password:
8749H323

Device scanning

EN0000DE00EN_0000
2005 Siemens AG

23

AP 1120

Siemens

Enter
IP-Adresse
192.168.0.1 and start
scanning operation.

Select AP 1120

24

EN0000DE00EN_0000
2005 Siemens AG

AP 1120

Siemens

Select AP 1120 and check the loaded Software.

EN0000DE00EN_0000
2005 Siemens AG

25

Siemens

AP 1120

Change the AP 1120 settings

IP-Address of the
TFTP-Server (PC) is:
1.30.21.2

Enter the directory of


the new Software.

26

EN0000DE00EN_0000
2005 Siemens AG

AP 1120

Siemens

AP 1120 Restart
Process: Click with the right mouse key on the AP, which you want to restart, and select
Restart (Abrupt) or Restart (Graceful);

Select AP

EN0000DE00EN_0000
2005 Siemens AG

27

Siemens

AP 1120

Connect the AP 1120 to the customer LAN (Port NETWORK) and change the IPAddress of the Admin-PC Network card !!!

28

Delete the AP 1120

EN0000DE00EN_0000
2005 Siemens AG

AP 1120

Siemens

Device scanning

Enter IP-Address range and start the scan


operation.

Control the scanning


time of the single IPAddresses.

EN0000DE00EN_0000
2005 Siemens AG

29

AP 1120

Siemens

Select AP 1120

30

EN0000DE00EN_0000
2005 Siemens AG

AP 1120

Siemens

Start the TFTP-Server (in this example: 3cDaemon)

Configure the TFTPServer

EN0000DE00EN_0000
2005 Siemens AG

31

AP 1120

Siemens

Start the Software Download


Process: Click with the right mouse key on the AP and select Download Software
(Abrupt);;

Select AP

32

EN0000DE00EN_0000
2005 Siemens AG

Siemens

Software is transfered to the AP 1120

EN0000DE00EN_0000
2005 Siemens AG

33

Siemens

AP 1120

Display the Status of the Download operation

Right mouse key;


select Edit SNMP;

If there was a Software change from H323/SIP to CorNet-IP, a Factory Reset has
to be started (see Indicators and connectors) !!!

34

EN0000DE00EN_0000
2005 Siemens AG

AP 1120

Siemens

Delete the AP 1120

Scan the devices again

Start the device scanning

Enter the IP-Address


range and start the
scan operation.

Select the AP 1120

EN0000DE00EN_0000
2005 Siemens AG

35

AP 1120

Siemens

Check the Software version


Select the AP 1120 and check the loaded Software.

36

EN0000DE00EN_0000
2005 Siemens AG

AP 1120

0.0.1

Siemens

Settings of the HiPath 4000 V2.0 data

Set Host-IP (STMI2 address)

Enter IP addresse of the


STMI2 board (HG3530)

Enter subscriber number

EN0000DE00EN_0000
2005 Siemens AG

37

Siemens

38

AP 1120

EN0000DE00EN_0000
2005 Siemens AG

AP 1120

Siemens

Set Port data

Europe: a-Law
USA: u_Law

EN0000DE00EN_0000
2005 Siemens AG

39

Siemens

AP 1120

Restart the AP 1120


Process: Click with the right mouse key on the AP, which you want to restart, and select
Restart (Abrupt);

40

EN0000DE00EN_0000
2005 Siemens AG

AP 1120

0.0.2

Siemens

General actions

AP 1120 Restart
Process: Click with the right mouse key on the AP, which you want to restart, and select
Restart (Abrupt) or Restart (Graceful);

EN0000DE00EN_0000
2005 Siemens AG

41

Siemens

AP 1120

Backup the AP 1120 data

To backup the AP 1120 data, a file with the name MacXXXXXX.cfg is created on the
Admin-PC (Upload). This file can be restored during trouble shooting or AP 1120
change (Download). So the AP 1120 has not be configured again in case of error.

42

EN0000DE00EN_0000
2005 Siemens AG

AP 1120

EN0000DE00EN_0000
2005 Siemens AG

Siemens

43

Siemens

44

AP 1120

Restore AP 1120 data

EN0000DE00EN_0000