Users Manual
Connect UPS to Power
Use the power cord that came with your computer to connect the UPS directly to the wall
outlet. Do not power the UPS using a surge
suppressor or power strip.
Use the supplied IEC cords to connect equipment to either Battery Backup or Surge Protection outlets.
5 hours
Connect Fax/Phone/Modem
Surge Protection (optional)
Circuit Breaker
On Battery (yellow)
On/Off Button
Press and release the On/Off button
to supply power to the Battery
Backup outlets. The UPS then performs a SelfTest. Press and release the button again to
switch Off power to the Battery Backup outlets.
Note: The Surge Protection outlet is powered
whenever the UPS has utility power.
On Line (green)
The UPS is supplying conditioned
utility power to the Battery Back-up
outlets.
Battery Backup outltets and is reset by switching the UPS Off and then On again.
Cold Start
Overload (red)
Manual Shutdown
Troubleshooting
Battery Replacement
To solve minor UPS installation problems, use the table below. To resolve complex UPS problems,
consult the APC web site (http://www.apcc.com), or contact APC Technical Support.
Symptom
Possible Cause
Solution
Computer interface
problem.
Single beep.
Battery requires
replacement.
PC and/or monitor is
plugged into the Surge
Protection outlet.
Weak battery.
Service
Please read the cautions in the APC Safety Information Guide first.
Pb
Pb
UPS Storage
Before storing, the UPS should be connected to utility power for at least 4-5 hours. Disconnect the
UPS from facility power, cover and store the UPS upright in a cool, dry location. During long-time
storage, the battery should be charged in accordance with the below:
Storage Temperature
Note: If the UPS requires service, do not return it to the dealer. The following
steps should be taken:
1.
2.
3.
4.
Note: Never use Styrofoam beads for packaging. Damage sustained in transit is not covered under
warranty (insuring the package for full value is recommended).
5. Write the RMA# on the outside of the package.
6. Return the UPS by insured, prepaid carrier to the address provided by customer service.
The standard warranty is 2 years from date of purchase. APC's standard procedure is to replace the
original unit with a factory reconditioned unit. APC will ship out the replacement unit once the
defective unit has been received by the repair department or cross ship upon the receipt of a valid
credit card number. The customer pays for the shipping to APC and APC pays ground freight
transportation costs back to the customer.
Customers who must have the original unit back due to assigned asset tags and set depreciation
schedules must declare such a need at first contact with APC Customer Service.
Charging Duration
Every 6 Months
10 Hours
Every 3 Months
10 Hours
http://www.apcc.com
Technical Support
http://support.apcc.com
India
91 44 433 1124
United States
Specifications
Expected runtime for a
Typical PC (110 Watts)
Acceptable Input Voltage
Input Voltage Range for On
Line Operation
Maximum Load
On Battery Output Voltage
Warranty
Recharge Frequency
19 Minutes
(For more accurate runtime information, consult http://www.apcc.com/sizing)
0 - 320 VAC, Single Phase
160 - 120 VAC
500 VA, 300 W
230 VAC + 8% of nominal input voltage
50 Hz - unless synchronized to utility during deep brownout.
Stepped sine-wave
Operating Temperature
Storage Temperature
0 to 95%, non-condensing
UPS Size (H x W x D)
UPS Weight
Shipping Weight