You are on page 1of 16

WIRE ROPE END CONNECTIONS

METRIC

Open Spelter Sockets


Closed Spelter Sockets
Short Bow Sockets
Fast Connector Sockets
Open Wedge Sockets
Closed Wedge Sockets
Open Swage Sockets
Closed Swage Sockets
Carbon Steel Sleeves

Bridge building industry


Offshore equipment
Dredging industry
Mooring systems
Cranes

PRODUCT INFORMATION

ROPEBLOCK YOUR PARTNER FOR


STANDARD AND CUSTUM DESIGNED SOCKETS
Ropeblock
Ropeblock BV is a Dutch producer of wire rope end connections. Beside sockets we produce a
variety of hookblocks for the mobile and offshore hoisting industry. We are located in Oldenzaal
in the Netherlands, wich is in the centre of Europe and can be easily reached by road or air.

Research & Design

Quality
The quality assurance program of Ropeblock BV
is ISO 9001 certified.

Materials
Our standard socket range is available in cast
alloy steel with high mechanical properties. The
Shortbow range is made of high alloy steel with
extremely high mechanical properties.
All our sockets are suitable for usage in a low
temperature enviroment. All of the materials
meet the requirements of an impact value of
42 Joule/-20C Charpy-V.

Testing
Sockets can be proofloaded in accordance with
the Ropeblock BV test program. Witnessing of
non-destructive examinations by independent
inspection agencies can be offered as an option.

Customer special needs


When customers needs go beyond our
standard line, Ropeblock BV excels through
innovative design. We meet each challenge
with a team of dedicated engineers including
advanced CAD and test equipment.
For more details visit our website:
www.ropeblock.nl

PAGE 2

SEE

With our 300 tons tensile testing equipment,


certified by TNO and approved by all major
classification societies, we can offer additional
proofload testing facilities.

OUR WARNING AND APPLICATION INSTRUCTIONS

Manufactures certificate
Sockets are supplied with a manufacturers
certificate showing:
certificate number
wirerope diameter
minimum breaking load (MBL)
quantity
order number

Fast Connector Sockets.


Special designed for mobile
cranes, and can be used with
high performance rotation
resistant and standard 6 strand
ropes. Fast connector sockets
have 100% efficiency. Sockets
and buttons are re-usable.

Material certificates
Additional material inspection and testing by
authorized agencies is possible. If ordered a
3.1.C-EN 10204/DIN 50049 certificate can be
supplied.

Open and Closed Wedge Sockets.


Quick dismountable socket
range for wirerope diameter
7 - 86 mm (5/16 - 33/8).
Basket and wedge in alloy
cast teel.

Finishing
Our standard sockets are delivered painted in
blue or hot dipped galvanized.

Stock
All our Sockets are available ex-stock, ensuring short-time deliveries.

Open and Closed Swage Sockets.


Swage sockets are recommended for use on 6x19 or
6x37 IWRC regular lay ropes and also satisfactory on
galvanized bridge rope. They are not recommended for
use on fiber core ropes.

Open and Closed Spelter Sockets.


Alloy cast steel range with high
mechanical values also for
low temperature use.
For wirerope diameter
11 - 130 mm (7/16 - 5),
socket pin locked by split
or by nut. Optional flange
connection for use of a
bend stiffener.

Carbon Steel Sleeves.


Proper swaging methods must be followed.
Proper swaging practices are the sling manufactures
responsibility. A color change will not indicate prober
swaging.

Short Bow Sockets.


The ultimate socket for dynamic
load. Towing lines, anchor lines,
chain-rope connections used by
major offshore contractors. High
alloy cast steel with extremely
high mechanical value.

SEE

PAGE 3

OUR WARNING AND APPLICATION INSTRUCTIONS

ALLOY CAST STEEL

OPEN SPELTER SOCKETS

Dimensions (mm)

for wire

Model No.

MBL
(tons)

(mm)

OSS 198
OSS 199
OSS 100
OSS 104
OSS 108
OSS 111
OSS 115
OSS 118
OSS 120
OSS 125
OSS 128
OSS 130
OSS 132
OSS 135
OSS 138
OSS 140
OSS 142
OSS 144
OSS 146
OSS 150

20
25
40
55
75
90
125
150
170
225
280
360
425
460
560
625
720
875
1200
1300

11 - 13
14 - 16
18 - 19
20 - 22
23 - 26
27 - 30
31 - 36
37 - 39
40 - 42
43 - 48
49 - 54
55 - 60
61 - 68
69 - 75
76 - 80
81 - 86
87 - 93
94 - 102
108 - 115
120 - 130

(inch)
7/

- 1/2
5
16 - /8
3/
4
7/
8

16

9/

1
11/8
11/4 - 13/8
11/2
15/8
13/4 - 17/8
2 - 21/8
21/4 - 23/8
21/2 - 25/8
23/4 - 27/8
3 - 31/8
31/4 - 33/8
31/2 - 35/8
33/4 - 4
41/4 - 41/2
43/4 - 5

TL

Weight
(kgs)

64
76
89
101
114
127
139
152
165
190
216
228
248
279
305
330
356
381
450
500

51
63
76
89
101
114
127
162
165
178
228
250
273
279
286
298
318
343
480
500

27
32
40
45
60
65
72
80
88
100
108
120
133
138
146
160
178
190
215
280

50
58
70
80
104
114
126
142
152
176
194
210
236
240
252
290
320
350
400
560

14
17,5
21
24
28
32
38
41
44
51
57
63
73
79
86
92
99
108
125
138

25
30
35
41
51
57
63
70
76
89
95
108
121
127
133
140
152
178
195
250

12
14
16
19
22
25
28
30
33
39
46
53
60
73
76
79
83
89
100
110

142
171
205
235
275
306
338
394
418
468
552
598
654
696
737
788
852
914
1145
1280

25
32
38
44
51
57
63
76
76
89
101
113
127
133
146
159
171
191
205
225

1
1,8
3,2
4,6
8
11
16
23
27
41
58
85
118
155
173
230
265
370
525
900

MBL = Minimum Breaking Load.


Standard all sockets are painted blue, but can be supplied galvanized.
All sockets can be supplied with EN 10204/DIN 50049 3.1B certificate (no additional costs).
Other than 3.1B certificates on request and at additional costs.

PAGE 4

SEE

OUR WARNING AND APPLICATION INSTRUCTIONS

ALLOY CAST STEEL

CLOSED SPELTER SOCKETS

MBL
(tons)

(mm)

CSS
CSS
CSS
CSS
CSS
CSS
CSS
CSS
CSS
CSS
CSS
CSS
CSS
CSS
CSS
CSS
CSS
CSS
CSS
CSS

20
25
40
55
75
90
125
150
170
225
280
360
425
460
560
625
720
875
1200
1300

11 - 13
14 - 16
18 - 19
20 - 22
23 - 26
27 - 30
31 - 36
37 - 39
40 - 42
43 - 48
49 - 54
55 - 60
61 - 68
69 - 75
76 - 80
81 - 86
87 - 93
94 - 102
108 - 115
120 -130

298
299
200
201
204
207
212
215
217
219
222
224
226
227
228
229
230
231
233
240

Dimensions (mm)

for wire

Model No.

(inch)
7/

- 1/2
5
16 - /8
3/
4
7/
8

16

9/

1
11/8
11/4 - 13/8
11/2
15/8
13/4 - 17/8
2 - 21/8
21/4 - 23/8
21/2 - 25/8
23/4 - 27/8
3 - 31/8
31/4 - 33/8
31/2 - 35/8
33/4 - 4
41/4 - 41/2
43/4 - 5

TA

TL

Weight
(kgs)

63,5
76
89
101
114
127
139
152
165
190
216
228
248
279
305
330
356
381
450
500

59
65
78
90
103
116
130
155
171
198
224
247
270
286
298
311
330
356
425
525

17,5
21
27
33
36
39
43
51
54
55
62
73
79
79
83
102
102
108
125
125

14
17,5
21
24
28
32
38
41
44
51
57
63
73
79
86
92
99
108
125
138

30
36
42
47
57
63
70
79
83
93
100
112
140
159
171
184
197
216
235
260

22,5
26
32
38
44
51
57
63
70
76
82
92
102
124
133
146
159
178
190
200

51
67
76
92
104
114
127
136
146
171
193
216
241
273
292
311
330
362
405
450

140
162
194
224
253
282
312
358
390
443
502
548
597
644
686
743
788
845
1000
1150

0,7
1,3
2,1
3,6
5,3
7
9,7
13
17
26
37,5
50
65
94
110
145
182
210
330
500

MBL = Minimum Breaking Load.


Standard all sockets are painted blue, but can be supplied galvanized.
All sockets can be supplied with EN 10204/DIN 50049 3.1B certificate (no additional costs).
Other than 3.1B certificates on request and at additional costs.

SEE

PAGE 5

OUR WARNING AND APPLICATION INSTRUCTIONS

HIGH ALLOY CAST STEEL

SHORT BOW SOCKETS

Dimensions (mm)

for wire

Model No.

MBL
(tons)

(mm)

(inch)

TA

TL

Weight
(kgs)

SBS
SBS
SBS
SBS
SBS
SBS
SBS
SBS
SBS
SBS
SBS

160
200
250
320
400
500
600
700
800
900
1000

37 - 42
43 - 48
49 - 54
55 - 60
61 - 68
69 - 75
76 - 80
81 - 86
87 - 93
94 - 102
108 - 115

11/2 - 15/8
13/4 - 17/8
2 - 21/8
21/4 - 23/8
21/2 - 25/8
23/4 - 27/8
3 - 31/8
31/4 - 33/8
31/2 - 35/8
33/4 - 4
41/4 - 41/2

162
188
204
230
235
287
314
327
358
365
420

103
120
132
148
165
178
195
216
220
235
270

38
42
54
62
68
75
76
82
92
100
110

44
51
57
63
73
79
86
92
99
105
115

92
112
120
135
150
164
175
194
202
215
240

147
178
200
220
250
274
295
320
350
375
410

300
348
390
440
468
540
585
625
670
700
800

9
15
22
27
40
54
75
81
115
130
180

517
519
522
524
526
527
528
529
530
531
533

MBL = Minimum Breaking Load.


Standard all sockets are painted blue, but can be supplied galvanized.
All sockets can be supplied with EN 10204/DIN 50049 3.1B certificate (no additional costs).
Other than 3.1B certificates on request and at additional costs.

PAGE 6

SEE

OUR WARNING AND APPLICATION INSTRUCTIONS

ALLOY CAST STEEL

FAST CONNECTOR SOCKETS

Model No.

FCS
FCS
FCS
FCS
FCS
FCS
FCS
FCS

701
702
703
704
705
706
707
708

Dimensions (mm)

for wire

MBL
(tons)

(mm)

20
25
40
55
75
90
125
125

11 - 13
13 - 16
16 - 19
20 - 22
23 - 26
27 - 29
30 - 32
33 - 36

(inch)
7/

- 1/2
5
2 - /8
5/
3
8 - /4
7/
8
16

1/

1
11/8
11/4
13/8

Weight
(kgs)

62
72
85
102
115
140
150
160

61
78
93
106
123
152
159
171

27
32
40
45
60
65
73
73

15
18
21
24
28
32
36
39

25
30
35
41
51
57
63
64

12
14
16
19
22
25
28
28

25
32
38
44
51
57
63
69

50
58
70
80
104
114
126
126

33
38
45
50
60
70
80
85

49
60
70
82
95
107
119
125

46
59
69
81
90
116
120
130

1,6
2,6
4,5
6,5
11
16
18
23

MBL = Minimum Breaking Load.


Standard all sockets are painted blue, but can be supplied galvanized.
All sockets can be supplied with EN 10204/DIN 50049 3.1B certificate (no additional costs).
Other than 3.1B certificates on request and at additional costs.

SEE

PAGE 7

OUR WARNING AND APPLICATION INSTRUCTIONS

WARNING AND
APPLICATION INSTRUCTIONS
General information

Spelter Sockets

- Always take care of visual inspection before


using a socket and pin.

- Proper spelter socket termination have an


effecienty of 100% of the breaking load of
the wire. This can be limitated by the
minimum braking load of the socket (MBL),
as mentioned in the tables.

- Never use a part showing cracks.


- Do not side load a socket.
- Repair is not allowed, for repair contact
your supplier.
- Never shockload a socket.

Required resin volume for


socketing wire rope terminations
For wire rope

Approximate
resin volume

mm

inch

cc

11 - 13
14 - 16
18 - 19
20 - 22
23 - 26
27 - 30
31 - 36
37 - 39
40 - 42
43 - 48
49 - 54
55 - 60
61 - 68
69 - 75
76 - 80
81 - 86
87 - 93
94 - 102
108 - 115
120 - 130

1/
2

35
50
80
120
160
220
350
425
500
700
1200
1450
1850
2250
3500
4000
5000
7500
10500
14000

PAGE 8

5/
8
3/
4
7/
8

1
11/8
1/
1 2 - 13/8
11/2
15/8
13/4 - 17/8
2 - 21/8
21/4 - 23/8
21/2 - 25/8
23/4 - 27/8
3 - 31/8
31/4 - 33/8
31/2 - 35/8
33/4 - 4
41/4 - 41/2
43/4 - 5

SEE

- Before use please carefully read the instructions


of the resin manufacturer. Incorrect use of the
resin or spelter material can result in an unsafe
termination. More information can also be
obtained from your wire rope supplier.
- Always clear the wire rope broom and socket
basket from dirt and grease.
- Make certain that the broomed wires are
evenly spaced in the basket, and that the wire
and basket are aligned with each other.
- When using white metal or zinc, do not
preheat the socket to more then 300C (570F).
- Make sure the base of the socket is properly
sealed. This to prevent resin leakage, which
may cause voids.
- Never use an assembly before the resin is fully
hardened.
- Socketing should always be done by a qualified
person.
- Due to constant improvements of our products,
we reserve the right to change specifications
accordingly.

OUR WARNING AND APPLICATION INSTRUCTIONS

WARNING AND
APPLICATION INSTRUCTIONS
Wedge Sockets

Swage Sockets and Sleeves

- Always mount the loaded part of the wire in


the centre line of the pin (see figures).

- Swage sockets are recommended for use on


6x19 or 6x37 IWRC regular lay ropes.
They are also satisfactory on galvanized
bridge rope. They are not recommended
for use on fibre core or lang lay ropes.

- Secure the dead end with a wirerope clip.


- Do not attach the loaded wire to the dead
end.
- The dead end should have a length of 6 times
the wire diameter with a minimum of 150 mm.
- Inspect after the first load that the wire rope
and wedge are fully seated.
- Load may slip if the connection is not properly
installed.
- Inspect the connection regularly.
- The efficiency of a wire rope/wedge socket
connection is 80% of the minimum breaking
load of the wire but limited to the minimum
breaking load of the socket (MBL).

- Proper swaging methods must be followed


for the above mentioned products.
Multiple progressive pressings are required
to prevent flash, which will develop into a
permanent mark or possibly a crack in the
sleeve.
- A light oil lubricant should be applied to each
die and wiped clean after swaging.
- For swaging practice detail contact the die
manufacturer.
- Swage sockets properly applied have an
efficiency rating of 100%. This rating is
based on the catalogue strength of wire rope.
- Caution: Proper swaging practices are the
sling manufacturer responsibility.

SEE

PAGE 9

OUR WARNING AND APPLICATION INSTRUCTIONS

ALLOY CAST STEEL

OPEN WEDGE SOCKETS

Model No.

MBL
(tons)

OWS 0,25
OWS 0,5
OWS 1
OWS 2
OWS 3
OWS 4
OWS 5
OWS 6
OWS 7
OWS 8
OWS 9
OWS 10
OWS 11
OWS 12
OWS 13
OWS 14
OWS 15
OWS 16

8
12
20
25
40
55
75
90
110
125
150
170
225
280
360
425
460
625

Dimensions (mm)

for wire
(mm)

(inch)

5/
7-8
16
3/
9 - 10
8
1/
11 - 13
2
5/
14 - 16
8
3/
18 - 19
4
7/
20 - 22
8
24 - 26
1
27 - 29
11/8
30 - 32
11/4
34 - 36
13/8
37 - 39
11/2
40 - 42
15/8
3/
43 - 48 1 4 - 17/8
49 - 52
2
54 - 58
21/4
60 - 68
21/2
72 - 76
3
1/
81 - 86 3 4 - 33/8

TL

Weight
(kgs)

110
142
146
176
212
240
274
310
350
400
450
500
550
640
660
835
1000
1100

19
23
29
35
40
48
55
65
73
74
80
87
100
105
125
135
150
152

36
46
57
70
80
95
110
130
146
148
143
160
186
194
230
250
270
300

16
20,6
25
30
35
41
51
57
64
64
70
76
89
95
108
121
133
140

9
11
12
15
16
19
22
25
28
28
30
33
39
46
54
60
76
79

129
165
175
211
252
288
329
375
423
474
530
587
650
745
785
970
1150
1252

18
20,5
25
31
38
44
51
57
63
69
76
76
89
101
114
127
146
159

0,8
1,7
2,1
4
7
10
15
21
31
37
51
64
96
130
180
275
440
510

MBL = Minimum Breaking Load.


Standard all sockets are painted blue, but can be supplied galvanized.
All sockets can be supplied with EN 10204/DIN 50049 3.1B certificate (no additional costs).
Other than 3.1B certificates on request and at additional costs.

PAGE 10

SEE

OUR WARNING AND APPLICATION INSTRUCTIONS

ALLOY CAST STEEL

CLOSED WEDGE SOCKETS

Model No.

MBL
(tons)

CWS 303
CWS 304
CWS 305
CWS 306
CWS 307
CWS 308
CWS 309
CWS 310
CWS 311
CWS 312
CWS 313
CWS 314
CWS 315
CWS 316

40
55
75
90
110
125
150
170
225
280
360
425
460
625

for wire
(mm)

18
20
24
27
30
34
37
40
43
49
54
61
72
81

Dimensions (mm)

(inch)

19
22
26
29
32
36
39
42
48
52
58
64
76
86

3/

7/

1
11/8
11/4
13/8
11/2
15/8
13/4 - 17/8
2
21/4
21/2
3
1/
3 8 - 31/4

TA

TL

Weight
(kgs)

220
225
290
325
360
400
500
600
640
720
775
900
1000
1125

100
225
130
145
160
180
240
310
325
375
400
470
500
550

34
42
50
60
68
68
72
80
90
100
110
120
130
135

40
47
55
70
75
75
80
90
100
110
120
130
150
165

90
110
125
152
165
165
185
210
225
245
265
290
330
360

254
267
340
385
428
468
572
680
730
820
885
1020
1130
1260

7
9
14
22
30
38
49
65
100
150
175
230
300
425

MBL = Minimum Breaking Load.


Standard all sockets are painted blue, but can be supplied galvanized.
All sockets can be supplied with EN 10204/DIN 50049 3.1B certificate (no additional costs).
Other than 3.1B certificates on request and at additional costs.

SEE

PAGE 11

OUR WARNING AND APPLICATION INSTRUCTIONS

FORGED CARBON STEEL

SWAGE SOCKETS OPEN

Model No.

SSO 06
SSO 08
SSO 10
SSO 11
SSO 13
SSO 14
SSO 16
SSO 19
SSO 22
SSO 25
SSO 29
SSO 32
SSO 35
SSO 38
SSO 44
SSO 51
SSO 57
SSO 63
SSO 76

Dimensions (mm)

for wire
(mm)

6
8
10
11
13
14
16
19
22
25
29
32
35
38
44
51
57
63
76

(inch)

TL

Weight
(kgs)

1/

12,7
19,6
19,6
24,9
24,9
31,8
31,8
39,4
43,2
50,5
57
64,5
71
78
86
100
113
125,2
150,6

6,85
8,65
10,4
12,2
14
15,5
17
20,3
23,9
26,9
30,2
33,8
36,8
40,1
47,2
53,5
59,9
67,5
80,4

17,5
20,6
20,6
25,4
25,4
30,2
30,2
35,1
41,1
51
57
63,5
63,5
70
89
95,5
108
108
133,4

38
44
44
51
51
57
57
70
83
95
108
121
133
146
171
203
171
171
219

121
159
159
198
198
243
243
297
346
397
444
494
540
591
689
798
835
879
1045

54
81
81
108
108
135
135
162
189
216
243
270
297
324
378
432
486
498
603

102
135
135
169
169
206
206
254
295
340
381
419
460
502
584
679
705
749
905

8
10
10
13
13
16
16
19
23
26
30
30
33
37
43
46
65
65
76

17
21
21
25
25
32
32
38
44
51
57
63
63
76
89
102
114
114
146

35
41
41
51
51
63
63
76
86
102
114
127
133
146
178
203
222
222
241

0,25
0,5
0,5
1,1
1,1
2,1
2,1
3,6
5,3
8,1
13,5
16,4
21,4
29,5
42,2
65,8
93,5
103
181,5

5/

16

3/

7/

16

1/

9/

16

5/

3/

7/

1
11/8
11/4
13/8
11/2
13/4
2
21/4
21/2
3

Swage sockets are recommended for use on 6x19 or 6x37 IWRC regular lay ropes and also satisfactory on galvanized
bridge rope. They are not recommended for use on fiber core ropes.
Before using swage sockets with other type lay, construction or grade of wire rope, it is recommended that the termination
be proofloaded to prove the adequacy of the assembly.
Sockets properly applied have an efficiency rating of 100% based on the catalog strenght of the used wire rope.
Forged from special steel for cold swaging.

PAGE 12

SEE

OUR WARNING AND APPLICATION INSTRUCTIONS

FORGED CARBON STEEL

SWAGE SOCKETS CLOSED

Model No.

SSC 06
SSC 08
SSC 10
SSC 11
SSC 13
SSC 14
SSC 16
SSC 19
SSC 22
SSC 25
SSC 29
SSC 32
SSC 35
SSC 38
SSC 44
SSC 51
SSC 57
SSC 63
SSC 76

Dimensions (mm)

for wire
(mm)

6
8
10
11
13
14
16
19
22
25
29
32
35
38
44
51
57
63
76

(inch)

TL

Weight
(kgs)

1/

12,7
19,6
19,6
24,9
24,9
31,8
31,8
39,4
43,2
50,5
57
64,5
71
78
86
100
113
125,2
150,6

6,85
8,65
10,4
12,2
14
15,5
17
20,3
23,9
26,9
30,2
33,8
36,8
40,1
47,2
53,5
59,9
67,5
80,4

37
43
43
51
51
63
63
76
89
102
114
127
133
140
171
197
219
219
235

19,1
22,4
22,4
26,9
26,9
31,8
31,8
36,6
42,9
52,5
58,5
65
65
71,5
90,5
96,5
109,5
109,5
134,9

13
17
17
22
22
29
29
33
38
44
51
57
57
63
76
83
102
102
137

54
81
81
108
108
135
135
162
189
216
243
270
297
324
378
432
486
498
603

111
140
140
176
176
222
222
264
308
349
387
438
479
518
610
698
756
791
959

89
114
114
146
146
184
184
219
257
292
324
365
400
432
508
584
632
667
816

0,15
0,36
0,35
0,7
0,7
1,3
1,3
2,3
3,4
5,1
7,2
10,5
14,1
17,7
23,6
40,8
55,4
64,4
114,3

5/

16

3/

7/

16

1/

9/

16

5/

3/

7/

1
11/8
11/4
13/8
11/2
13/4
2
21/4
21/2
3

Swage sockets are recommended for use on 6x19 or 6x37 IWRC regular lay ropes and also satisfactory on galvanized
bridge rope. They are not recommended for use on fiber core ropes.
Before using swage sockets with other type lay, construction or grade of wire rope, it is recommended that the termination
be proofloaded to prove the adequacy of the assembly.
Sockets properly applied have an efficiency rating of 100% based on the catalog strenght of the used wire rope.
Forged from special steel for cold swaging.

SEE

PAGE 13

OUR WARNING AND APPLICATION INSTRUCTIONS

ALLOY FORCED STEEL

CARBON STEEL SLEEVES

Dimensions (mm)

for wire
Color

Model No.
(mm)

SSL 06
SSL 08
SSL 10
SSL 11
SSL 13
SSL 14
SSL 16
SSL 19
SSL 22
SSL 26
SSL 29
SSL 32
SSL 35
SSL 38
SSL 45
SSL 52
SSL 57
SSL 64

6
8
10
11
13
14
16
18 - 19
22
25 - 26
28 - 29
31 - 32
34 - 35
37 - 38
44 - 45
50 - 52
56 - 57
62 - 64

(inch)
1/

5/

16

3/

7/

16

1/

9/

16

5/

3/

7/

1
11/8
11/4
13/8
11/2
13/4
2
21/4
21/2

Gold
Red
Green
Blue
Gold
Red
Green
Blue
Gold
Slf Clrd
Slf Clrd
Slf Clrd
Slf Clrd
Slf Clrd
Slf Clrd
Slf Clrd
Slf Clrd
Slf Clrd

Wall
thickness

After Swage
dia.

Weight
(kgs)

25,4
38,1
38,1
51
51
70
70
81
90
102
122
132
148
159
184
216
243
267

16.7
23
23
31
31
37
37
43,7
51,6
58
64
70,6
76
82,6
98
111
128
140

8,3
11,1
11,9
14,3
15,9
17,5
19,1
23,4
26,2
29,4
32,5
36,5
39,7
42,9
49,2
57,2
63,5
69,9

11,9
15,5
16,7
21,4
23
26,2
27,8
32,5
38,9
43,7
49,2
54,8
60,3
66,7
79,4
92,1
102,4
114,3

7,1
11,1
11,1
15,1
15,1
17,9
17,9
21,8
25,4
28,6
31,8
35,7
39,7
42,9
50
57,2
64,3
71,4

2,4
3,8
3,2
4,8
4
5,4
4,6
5,6
6,4
7,2
7,4
7,9
7,9
7,9
9,3
9,5
12,8
12,8

12,7
18,5
18,5
24,9
24,9
30,5
30,5
35,8
41,4
47,8
52,8
57,7
62,5
67,3
77,2
88,9
103,1
112,8

0,02
0,06
0,05
0,15
0,13
0,3
0,25
0,4
0,6
0,9
1,2
1,5
1,9
2,4
3,8
5,1
8,7
10,5

Proper swaging methods must be followed.


Proper swaging practices are the sling manufactures responsibility.
A color change will not indicate proper swaging.

PAGE 14

SEE

OUR WARNING AND APPLICATION INSTRUCTIONS

Ropeblock your partner for standard and custom designed


craneblocks, craneblock components, accessories and swivels.
CRANE BLOCKS
type FRB

S
CRA PECIA
L
NE
BLO
CKS

CRANE BLOCKS
type OHB
SP

EC

IAL

BL
OC

KS

CRANE BLOCKS
type SRB

SPECIAL BLOCKS

SPECIAL BLOCKS

CAST SHEAVES, NYLON SHEAVES, STEEL SHEAVES, BEARINGS,


SWIVEL HOOKS, CONNECTING LINKS, SHACKLES, HOOK, HOOK SUSPENSIONS
SEE

PAGE 15

OUR WARNING AND APPLICATION INSTRUCTIONS

PRODUCT INFORMATION

DAY-TO-DAY DELIVERY
ALL OVER THE WORLD
A huge stock in hookblock components, and sockets makes
us an interesting partner.

LTI Steel Wire Rope(Shanghai) Co.,Ltd.


Add.:No.112 FuTeDongYi Rd.WaiGaoQiao Free
Trade Zone,Shanghai China(200131)
Tel:021-58666268
Fax:021-58666090
E-mail:info@gangsisheng.com

RopeBlock BV
P.O.Box 391
7570 AJ Oldenzaal
The Netherlands
Tel: +31 (0)541-532300
Fax: +31 (0)541-536575
E-mail: info@ropeblock.nl
Homepage: www.ropeblock.nl
Copyright 2004 by Ropeblock BV.
In this catalogue we have endeavoured to make the information as accurate as possible.
We cannot accept any responsibility should it be found that in any respect the information is
inaccurate or incomplete or becomes so as a result of further developments.

Design: Digitale Vormgeving, Oldenzaal


www.digitalevormgeving.nl
Ropeblock BV. 3e revisie february 2007

You might also like