TEST REPORT NUMBER - 137-11

EN 55024:1998 + A1:2001 + A2:2003 + IS1:2007


INFORMATION TECHNOLOGY EQUIPMENTIMMUNITY CHARACTERISTICS
LIMITS AND MEASUREMENTS
EN 61000-4-2 ELECTROSTATIC DISCHARGE IMMUNITY
EN 61000-4-3 RADIATED RADIO FREQUENCY (RF) IMMUNITY
EN 61000-4-4 ELECTRICAL FAST TRANSIENT/BURST IMMUNITY
EN 61000-4-5 SURGE IMMUNITY
EN 61000-4-6 CONDUCTED RF DISTURBANCE IMMUNITY
EN 61000-4-11 VOLTAGE DIPS INTERRUPTIONS AND VARIATIONS
for

Siemens Enterprise Communications, Inc.


5500 Broken Sound Road
Boca Raton, FL 33487
of

OpenScape 50i DP14E


on
February 9 11, 2011
Tested by

Reviewed by

This report may not be reproduced except in full without written permission from Compliance Worldwide,
Inc.

Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873


(603) 887 3903 Fax (603) 887 6445
www.complianceworldwide.com

Test Number - 137-11


Siemens Enterprise Communications, Inc.
OpenScape 50i - DP14E

TABLE OF CONTENTS

OVERVIEW

1.0

ELECTROSTATIC DISCHARGE TEST

2.0

RADIATED RADIO-FREQUENCY TEST

3.0

ELECTRICAL FAST TRANSIENT/BURST TEST

4.0

SURGE TEST

5.0

CONDUCTED RF TEST

6.0

UNUSED SECTIONS
VOLTAGE DIPS, INTERRUPTIONS, VARIATIONS

Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873


(603) 887 3903 Fax (603) 887 6445
www.complianceworldwide.com

7 TO 10
11.0

Page 2 of 33

Test Number - 137-11


Siemens Enterprise Communications, Inc.
OpenScape 50i - DP14E

1.0 OVERVIEW
1.1 PURPOSE OF TEST
This report has been compiled to document the Immunity (Susceptibility) test
parameters, effects and results of the OpenScape 50i - DP14E in comparison to the
requirements for equipment as specified in the documents listed below. All results are
based on a test of one sample, and represent other production units, only in as much as
a sample represents other production units. If any significant changes are made to the
unit, the changes shall be evaluated and a retest may be required.
89/336/EEC (3 May 1989) Official Journal of the European Communities
Council Directive on Electromagnetic Compatibility

91/31/EEC (28 April 1992) Official Journal of the European Communities


Amending Directive 89/336/EEC on:
Council Directive on Electromagnetic Compatibility

1999/5/EC (9 March 1999) Official Journal of the European Communities


Council Directive on Radio Equipment and
Telecommunications Terminal Equipment

EN 61000-6-1 (2001)

Electromagnetic Compatibility - Generic Immunity Standard


Part 1: Residential, commercial and light industry

EN55024 (1998-09)

Information technology equipment Immunity


characteristics - Limits and methods of measurement

EN 55024 (2001)

Amendment 1

EN 55024 (2003)

Amendment 2

EN 55024 (2007)

Interpretation Sheet 1

Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873


(603) 887 3903 Fax (603) 887 6445
www.complianceworldwide.com

Page 3 of 33

Test Number - 137-11


Siemens Enterprise Communications, Inc.
OpenScape 50i - DP14E

1.1 OVERVIEW
1.1 PURPOSE OF TEST (cont.)
EN61000-4-2 (1995-01)

Electromagnetic Compatibility (EMC)


Part 4: Testing and measurement techniques Section 2 Electrostatic Discharge Immunity Test

EN61000-4-2 (1998)

Electromagnetic Compatibility (EMC) Amendment A1

EN61000-4-2 (2002)

Electromagnetic Compatibility (EMC) Amendment A2

EN61000-4-3 (1995-02)

Electromagnetic Compatibility (EMC)


Part 4: Testing and measurement techniques Section 3 Radiated, Radio-Frequency Immunity Test

EN61000-4-3 (1998)

Electromagnetic Compatibility (EMC) Amendment A1

EN61000-4-3 (2001)

Electromagnetic Compatibility (EMC) Amendment A2

EN61000-4-3 (2002)

Electromagnetic Compatibility (EMC)


Part 4: Testing and measurement techniques Section 3 Radiated, Radio-Frequency Immunity Test

EN61000-4-3 (2002)

Electromagnetic Compatibility (EMC) Amendment A1

EN61000-4-4 (1995-01)

Electromagnetic Compatibility (EMC)


Part 4: Testing and measurement techniques Section 4 Electrical Fast Transient/Burst Immunity Test

EN61000-4-4 (2001))

Electromagnetic Compatibility (EMC) Amendment A1

EN61000-4-4 (2001))

Electromagnetic Compatibility (EMC) Amendment A2

EN61000-4-4 (2004)

Electromagnetic Compatibility (EMC)


Part 4: Testing and measurement techniques Section 4 Electrical Fast Transient/Burst Immunity Test

Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873


(603) 887 3903 Fax (603) 887 6445
www.complianceworldwide.com

Page 4 of 33

Test Number - 137-11


Siemens Enterprise Communications, Inc.
OpenScape 50i - DP14E

1.1 PURPOSE OF TEST (cont.)

EN61000-4-5 (1995-02)

Electromagnetic Compatibility (EMC)


Part 5 Testing and measurement techniques Section 5 Surge Immunity Test

EN61000-4-5 (2001)

Electromagnetic Compatibility (EMC) Amendment A1

EN61000-4-6 (1996-03)

Electromagnetic Compatibility (EMC)


Part 6: Testing and measurement techniques Section 6 Immunity to conducted disturbances, induced by
Radio frequency fields.

EN61000-4-6 (2001)

Electromagnetic Compatibility (EMC) Amendment A1

EN61000-4-11(1994-06)

Electromagnetic Compatibility (EMC)


Part 11: Testing and measurement techniques Section Voltage dips, short interruptions and voltage
Variations immunity Test

EN61000-4-11(2001)

Electromagnetic Compatibility (EMC) Amendment A1

EN61000-4-11(2004)

Electromagnetic Compatibility (EMC)


Part 11: Testing and measurement techniques Section Voltage dips, short interruptions and voltage
Variations immunity Test

Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873


(603) 887 3903 Fax (603) 887 6445
www.complianceworldwide.com

Page 5 of 33

Test Number - 137-11


Siemens Enterprise Communications, Inc.
OpenScape 50i - DP14E

1.2 Product Identification


Product Details
Manufacturer:

Siemens Enterprise Communications, Inc.

Model Number:

OpenScape 50i DP14E

Serial Number:

KSA0260256
Branch solution providing SIP trunking, built in Media Server, 50 users
capability
230 VAC, 50 Hz

Description:
Input Power:
Product Configuration
Support Equipment
Device
Telephones (2)

Manufacturer
Emerson

Model

Serial No.

EM2115RW

Telephones (2)

Cables
Cable Type

Length

Shield

From

To

Ethernet (2)

1M

No

EUT

Unterm

USB (4)

3M

Yes

EUT

Unterm

Phone (2)

3M

No

EUT Port 1and Port 4

Phone

Phone (2)

3M

No

EUT Port 2 and Port 3

Unterm (2)

E1 ISDN PRI

3M

No

EUT

Unterm

Modifications performed on product at test facility: Per customer request, added Ferrite,
Wurth # 742 715 4 to telephone ports 1 - 4. One ferrite with all four wires going threw 2 turns.

Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873


(603) 887 3903 Fax (603) 887 6445
www.complianceworldwide.com

Page 6 of 33

Test Number - 137-11


Siemens Enterprise Communications, Inc.
OpenScape 50i - DP14E

1.3

BLOCK DIAGRAM

E1 ISDN
PRI

Port
1

serial

vga

Ethernet
Unterm
230 VAC, 60 Hz

USB
Unterm

Ethernet
Unterm
Phone
Unterm
Phone

Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873


(603) 887 3903 Fax (603) 887 6445
www.complianceworldwide.com

Phone

Page 7 of 33

Test Number - 137-11


Siemens Enterprise Communications, Inc.
OpenScape 50i - DP14E

2.0

EN 61000-4-2 ELECTROSTATIC DISCHARGE TEST DESCRIPTION

2.1 TEST SETUP


The EUT setup was placed in the ESD test laboratory in accordance with EN 55024 and
the IEC standard, with the following climatic conditions:
Temperature:

23 degrees C

Relative Humidity: 30%


The EUT was connected as diagrammed in Section 1.3 of this report.
A horizontal coupling plane (HCP) was placed on a non-conductive table, 0,8 meters
above the ground plane and connected to the ground plane through two 470-kohm
resistors. The EUT was placed on the table with an insulating support between the EUT
and the HCP. The ESD simulator was charged and allowed to discharge through the
HCP See section 9 for photographs of typical setups.
A vertical coupling plane (VCP) measuring 0,5m by 0,5m was fixed 0,1m from the
vertical surfaces of the equipment, parallel to them and connected to the ground plane
through two series 470 kohm resistors. The ESD simulator was charged and allowed to
discharge to the VCP. This test was repeated until all vertical surface areas of the EUT
were exposed to the VCP.
The ESD events were applied to such points and surfaces of the EUT that are normally
accessible to the operator for normal operation or maintenance. Contact discharge is
the preferred test method. Air discharges are used where contact discharge cannot be
applied.
NOTES:
1.

See Section 2.5 for ESD test locations.

Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873


(603) 887 3903 Fax (603) 887 6445
www.complianceworldwide.com

Page 8 of 33

Test Number - 137-11


Siemens Enterprise Communications, Inc.
OpenScape 50i - DP14E

2.2

TEST RESULTS

The OpenScape 50i - DP14E meets the requirements set forth in EN 61000-4-2.
Detailed test results are found in the following table(s).
2.3

TEST DATA

The test results are based upon 10 discharges at both polarities at each test point
Contact Discharge Data
PERFORMANCE CATEGORY
Level 1
VOLTAGE=>
Position Key
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

Level 2

2K V
+
A
A
A
A
A
A
A
A
A
A

Level 3

4K V
-

+
A
A
A
A
A
A
A
A
A
A

A
A
A
A
A
A
A
A
A
A

Level 4

6K V
-

8K V
-

A
A
A
A
A
A
A
A
A
A

Indirect Discharge
PERFORMANCE CATEGORY
VOLTAGE=>
Coupling Plane
Orientation
Horizontal (table top)
Vertical (Front)
Vertical (Left)
Vertical (Rear)
Vertical (Right)

Level 1
2K V
+
A
A
A
A
A

A
A
A
A
A

Level 2
4K V
+
A
A
A
A
A

Level 3
6K V
+

Level 4
8K V
+

A
A
A
A
A

Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873


(603) 887 3903 Fax (603) 887 6445
www.complianceworldwide.com

Page 9 of 33

Test Number - 137-11


Siemens Enterprise Communications, Inc.
OpenScape 50i - DP14E

2.3

TEST DATA (Continued)

Air Discharge Data: No discharges occurred due to plastic


PERFORMANCE CATEGORY

VOLTAGE=>
Position Key
A1
A2
A3
A4
A5
A6
A7
A8
A9
A10

Level 1

Level 2

Level 3

Level 4

2K V

4K V

8K V

15K V

+
ND

ND

+
ND

ND

PERFORMANCE CATEGORY EXPLANATION


Criterion A - Normal Performance within specified limits.
Normal status as monitored. Maintains call and is able to make call upon
completion.
Criterion B Temporary degradation occurred during the test. Normal
performance restored and no change of operating state or stored data after the
test.

Criterion C Temporary loss of function occurred that is self-recoverable or


temporary loss of function, which requires operator intervention.

Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873


(603) 887 3903 Fax (603) 887 6445
www.complianceworldwide.com

Page 10 of 33

Test Number - 137-11


Siemens Enterprise Communications, Inc.
OpenScape 50i - DP14E

2.4

TEST EQUIPMENT

Equipment

Serial #

082 197-25
082 213-09

Haefely PSD 25B


Haefely Contact Probe

Verification Due

1/24/2012
1/24/2012

All equipment used for testing has been calibrated according to the methods and
procedures defined by the National Institute of Standards and Technology (NIST).

Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873


(603) 887 3903 Fax (603) 887 6445
www.complianceworldwide.com

Page 11 of 33

Test Number - 137-11


Siemens Enterprise Communications, Inc.
OpenScape 50i - DP14E

2.5

TEST POINT DIAGRAM


Back

8
1

Port
1

serial
2

vga

10

Front

Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873


(603) 887 3903 Fax (603) 887 6445
www.complianceworldwide.com

Page 12 of 33

Test Number - 137-11


Siemens Enterprise Communications, Inc.
OpenScape 50i - DP14E

2.6

ELECTROSTATIC DISCHARGE PHOTOGRAPHS

Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873


(603) 887 3903 Fax (603) 887 6445
www.complianceworldwide.com

Page 13 of 33

Test Number - 137-11


Siemens Enterprise Communications, Inc.
OpenScape 50i - DP14E

3.0 EN 61000-4-3 RADIATED RADIO-FREQUENCY TEST DESCRIPTION


3.1 TEST SETUP
The EUT setup was placed in a calibrated uniform field in the ferrite tile chamber. The
field was calibrated using the test methodology in the IEC standard. The following
climatic conditions existed:
Temperature:

23.5 degrees C

Relative Humidity: 30%


The EUT was connected as diagrammed in Section 1.3 of this report. All testing and
verification for EUT operation was monitored utilizing the color camera system
contained in the chamber and/or external peripheral equipment located outside of the
chamber. The customer was not present during testing.

3.2

TEST RESULTS

The OpenScape 50i - DP14E meets the requirements set forth in EN 55024 and EN
61000-4-3.

Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873


(603) 887 3903 Fax (603) 887 6445
www.complianceworldwide.com

Page 14 of 33

Test Number - 137-11


Siemens Enterprise Communications, Inc.
OpenScape 50i - DP14E

3.3 TEST DATA


SIDE OF
EUT

POLARITY
(H / V)

FREQUENCY
(MHz)

VOLTS PER
METER

1kHz
80% AM

PERFORMANCE
CATEGORY

FRONT
FRONT
LEFT
LEFT
RIGHT
RIGHT
BACK
BACK

V
H
V
H
V
H
V
H

80 - 1000
80 - 1000
80 - 1000
80 - 1000
80 - 1000
80 - 1000
80- 1000
80 - 1000

3
3
3
3
3
3
3
3

YES
YES
YES
YES
YES
YES
YES
YES

A
A
A
A
A
A
A
A

PERFORMANCE CATEGORY EXPLANATION


Criterion A - Normal Performance within specified limits.
Normal status as monitored. Maintains call and is able to make call upon
completion.
Criterion B - Temporary degradation occurred during the test. Normal
performance restored and no change of operating state or stored data after the
test.

Criterion C - Temporary loss of function occurred that is self-recoverable or


temporary loss of function, which requires operator intervention.

Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873


(603) 887 3903 Fax (603) 887 6445
www.complianceworldwide.com

Page 15 of 33

Test Number - 137-11


Siemens Enterprise Communications, Inc.
OpenScape 50i - DP14E

3.4 TEST EQUIPMENT


Characterized/Verified Equipment Serial #

Due Date

Fluke 6060A Generator


IFI LPA-5B Leveling Amplifier
IFI SMX100 Wideband Amplifier
HP 8648C RF Signal Generator
GTC RF Amplifier 5016A
Narda E-Field Probe 8760
Narda E-Field Probe 8760
Chase CBL6121A BiConilog
EMCO 3143 Log Periodic Ant

3775031
806-1095
803-1095
3623A03429
1170
9022
9025
1015
9112-1046

*
*
*
*
*
Verified
Verified
8/30/2011
8/30/2011

Calibrated Equipment
Boonton 4220A Power Meter
IFI EFS-5 E-Field Sensor
IFI EFS-5 E-Field Sensor
Schaffner EMR-200 Field Probe

Serial #
203603AA
807
808
S-0051

5/28/2012
5/28/2012

* Signal Generator and Amplifier are characterized with Uniform Field Calibration
Equipment

Serial #

Chamber 3v/m Uniform Field


Chamber 10v/m Uniform Field

R2338
R2338

All equipment used for testing has been calibrated according to the methods and
procedures defined by the National Institute of Standards and Technology (NIST).

Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873


(603) 887 3903 Fax (603) 887 6445
www.complianceworldwide.com

Page 16 of 33

Test Number - 137-11


Siemens Enterprise Communications, Inc.
OpenScape 50i - DP14E

3.5 RADIATED LOW RADIO FREQUENCY PHOTOGRAPHS

Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873


(603) 887 3903 Fax (603) 887 6445
www.complianceworldwide.com

Page 17 of 33

Test Number - 137-11


Siemens Enterprise Communications, Inc.
OpenScape 50i - DP14E

4.0 EN 61000-4-4 ELECTRICAL FAST TRANSIENT/BURST TEST DESCRIPTION


4.1 TEST SETUP
The EUT setup was placed in the EFT test laboratory in accordance with EN 55024 and
the IEC standard, with the following climatic conditions:
Temperature:

22.5 degrees C

Relative Humidity: 30%


The EUT was connected as diagrammed in Section 1.3 of this report. All testing and
verification for EUT operation was monitored. The customer was not present during
testing.

The EFT events were applied to the Mains and to cables at each I/O port of the EUT
that are normally accessible to the operator for normal operation or maintenance.
NOTES:
1.

See Section 1.3 for the block diagram of the EUT setup.

4.2

TEST RESULTS

The OpenScape 50i - DP14E meets the requirements set forth in EN 61000-4-4.
Detailed test results are found in the following table(s).

Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873


(603) 887 3903 Fax (603) 887 6445
www.complianceworldwide.com

Page 18 of 33

Test Number - 137-11


Siemens Enterprise Communications, Inc.
OpenScape 50i - DP14E

4.3 TEST DATA


POWER PERFORMANCE CATEGORY
Level 1 Level 2 Level 3 Level 4
VOLTAGE=>

Line
N
N
L
L
PE
PE

Polarity
+
+
+
-

0.5KV

1KV

B
B
B
B
B
B

2KV

4KV

B
B
B
B
B
B

I/O POWER PERFORMANCE CATEGORY


Level 1 Level 2 Level 3 Level 4
VOLTAGE=>

I/O or Group
T1
T1

Polarity
+
-

0.25KV

A
A

.5KV

1KV

2KV

A
A

PERFORMANCE CATEGORY EXPLANATION


Criterion A - Normal Performance within specified limits.

Normal status as monitored. Maintains call and is able to make call upon
completion.
Criterion B - Temporary degradation occurred during the test. Normal performance
restored and no change of operating state or stored data after the test.
Temporary degradation during test, errors on T1. Normal performance restored after
test.
Criterion C - Temporary loss of function occurred that is self-recoverable or temporary
loss of function, which requires operator intervention.
Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873
(603) 887 3903 Fax (603) 887 6445
www.complianceworldwide.com

Page 19 of 33

Test Number - 137-11


Siemens Enterprise Communications, Inc.
OpenScape 50i - DP14E

4.4 TEST EQUIPMENT


Equipment

Serial #

Haefely PEFT.1
Haefely Coupling Clamp IP4A

081-944-23
082 148-17

Verification Due
9/2/2011
9/2/2011

All equipment used for testing has been calibrated according to the methods and
procedures defined by the National Institute of Standards and Technology (NIST).

Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873


(603) 887 3903 Fax (603) 887 6445
www.complianceworldwide.com

Page 20 of 33

Test Number - 137-11


Siemens Enterprise Communications, Inc.
OpenScape 50i - DP14E

4.5 ELECTRICAL FAST TRANSIENT/BURST PHOTOGRAPHS

Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873


(603) 887 3903 Fax (603) 887 6445
www.complianceworldwide.com

Page 21 of 33

Test Number - 137-11


Siemens Enterprise Communications, Inc.
OpenScape 50i - DP14E

5.0 EN 61000-4-5 SURGE IMMUNITY TEST DESCRIPTION

5.1 TEST SETUP


The EUT setup was placed in the Surge test laboratory in accordance with EN 55024
and the IEC standard, with the following climatic conditions:
Temperature:

23 degrees C

Relative Humidity:

30%

The EUT was connected as diagrammed in Section 1.3 of this report. All testing and
verification for EUT operation was monitored. The customer was not present during
testing.

The Surge events were applied to the Mains of the EUT. The mains power was supplied
from a 50Hz 230VAC source.
NOTES:
1.

See Section 1.3, for the block diagram of the EUT setup.

5.2

TEST RESULTS

The OpenScape 50i - DP14E meets the requirements set forth in EN 61000-4-5.
Detailed test results are found in the following table(s).

Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873


(603) 887 3903 Fax (603) 887 6445
www.complianceworldwide.com

Page 22 of 33

Test Number - 137-11


Siemens Enterprise Communications, Inc.
OpenScape 50i - DP14E

5.3 TEST DATA


SURGE PERFORMANCE CATEGORY
Level 1 Level 2 Level 3 Level 4
VOLTAGE=>

Line Polarity
L-PE
+
L-PE
N-PE
+
N-PE
L-N
+
L-N
-

0.5KV

1KV

A
A
A
A
A
A

2KV

A
A
A
A
A
A

4KV

A
A
A
A

I/O SURGE PERFORMANCE CATEGORY


Level 1 Level 2 Level 3 Level 4
VOLTAGE=>

I/O or Group
T1
T1

Polarity
+
-

0.25KV

A
A

.5KV

A
A

1KV

2KV

A
A

PERFORMANCE CATEGORY
Criterion A - Normal Performance within specified limits.
Normal status as monitored. Maintains call and is able to make call upon
completion.
Criterion B - Temporary degradation occurred during the test. Normal
performance restored and no change of operating state or stored data after the
test.
Criterion C - Temporary loss of function occurred that is self-recoverable or
temporary loss of function, which requires operator intervention.
Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873
(603) 887 3903 Fax (603) 887 6445
www.complianceworldwide.com

Page 23 of 33

Test Number - 137-11


Siemens Enterprise Communications, Inc.
OpenScape 50i - DP14E

5.4 TEST EQUIPMENT


Equipment

Serial #

Haefely P-Surge 4.1

083-061-06

Verification Due
1/18/2012

All equipment used for testing has been calibrated according to the methods and
procedures defined by the National Institute of Standards and Technology (NIST).

Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873


(603) 887 3903 Fax (603) 887 6445
www.complianceworldwide.com

Page 24 of 33

Test Number - 137-11


Siemens Enterprise Communications, Inc.
OpenScape 50i - DP14E

5.5 SURGE IMMUNITY PHOTOGRAPHS

Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873


(603) 887 3903 Fax (603) 887 6445
www.complianceworldwide.com

Page 25 of 33

Test Number - 137-11


Siemens Enterprise Communications, Inc.
OpenScape 50i - DP14E

6.0 EN 61000-4-6 CONDUCTED DISTURBANCE RADIO-FREQUENCY TEST


DESCRIPTION
6.1 SETUP
The EUT setup was placed in the ferrite tile chamber in accordance with EN 55024 and
the IEC standard, with the following climatic conditions:
Temperature:

22.5 degrees C

Relative Humidity:

30%

The EUT was connected as diagrammed in Section 1.3 of this report. All testing and
verification for EUT operation was monitored utilizing the color camera system
contained in the chamber and/or external peripheral equipment located outside of the
chamber. The customer was not present during testing.

6.2

TEST RESULTS

The OpenScape 50i - DP14E meets the requirements set forth in EN 61000-4-6.

Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873


(603) 887 3903 Fax (603) 887 6445
www.complianceworldwide.com

Page 26 of 33

Test Number - 137-11


Siemens Enterprise Communications, Inc.
OpenScape 50i - DP14E

6.3 TEST DATA


AC
FREQUENCY
(MHz)

.15-80
I/O
FREQUENCY
(MHz)

.15-80

CDN-M3 3 WIRE POWER INJECTION


VOLTS
1kHz
PERFORMANCE
RMS
80% AM
CATEGORY

YES

CDN-BCIP BULK CABLE INDUCED


VOLTS
1kHz
PERFORMANCE
RMS
80% AM
CATEGORY

YES

PERFORMANCE CATEGORY EXPLANATION


Criterion A - Normal Performance within specified limits.
Normal status as monitored. Maintains call and is able to make call upon
completion.
Criterion B - Temporary degradation occurred during the test. Normal
performance restored and no change of operating state or stored data after the
test.
Criterion C - Temporary loss of function occurred that is self-recoverable or
temporary loss of function, which requires operator intervention.

Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873


(603) 887 3903 Fax (603) 887 6445
www.complianceworldwide.com

Page 27 of 33

Test Number - 137-11


Siemens Enterprise Communications, Inc.
OpenScape 50i - DP14E

6.4 TEST EQUIPMENT


Characterized/Verified Equipment Serial #

Due Date

Fluke 6060A Generator


IFI SMX100 Wideband Amplifier
CW-CDN-M3
CW-CDN-S1 (100 ohm)
Fischer FCC-TLISN-T2
Fischer FCC-801-M2-16A
Fischer Bulk Current F-120-9A
Schaffner CDN-T400

7/23/2011
7/23/2011
7/23/2011
7/23/2011
7/23/2011
7/23/2011

3775031
803-1095
CW001
CW001
20098
2027
293
16901

Calibrated Equipment

Serial #

Boonton 4220A Power Meter

203603AA

* Signal Generator and Amplifier are characterized with each CDN


All equipment used for testing has been calibrated according to the methods and
procedures defined by the National Institute of Standards and Technology (NIST).

Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873


(603) 887 3903 Fax (603) 887 6445
www.complianceworldwide.com

Page 28 of 33

Test Number - 137-11


Siemens Enterprise Communications, Inc.
OpenScape 50i - DP14E

6.5 POWER CONDUCTED RADIO FREQUENCY PHOTOGRAPHS

Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873


(603) 887 3903 Fax (603) 887 6445
www.complianceworldwide.com

Page 29 of 33

Test Number - 137-11


Siemens Enterprise Communications, Inc.
OpenScape 50i - DP14E

11.0 EN 61000-4-11 VOLTAGE DIPS, SHORT INTERRUPTIONS, VARIATIONS

11.1 TEST SETUP


The EUT setup was placed in the test laboratory in accordance with EN 55024 and the
IEC standard, with the following climatic conditions:
Temperature:

22.5 degrees C

Relative Humidity:

30%

The EUT was connected as diagrammed in Section 1.3 of this report. All testing and
verification for EUT operation was monitored. The customer was not present during
testing.

The Voltage dips and interruptions were applied to the Mains of the EUT. The mains
power was supplied from a 50 Hz 230 VAC source.
NOTES:
1.

See Section 1.3 for the block diagram of the EUT setup.

11.2

TEST RESULTS

The OpenScape 50i - DP14E meets the requirements set forth in EN 61000-4-11.
Detailed test results are found in the following table(s).

Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873


(603) 887 3903 Fax (603) 887 6445
www.complianceworldwide.com

Page 30 of 33

Test Number - 137-11


Siemens Enterprise Communications, Inc.
OpenScape 50i - DP14E

11.3

TEST DATA

VOLTAGE DIPS PERFORMANCE CATEGORY

%
REDUCTION
>95
30
>95

PERIOD START
POINT
(DEGREES)
.5
0 AND 180
25
0 AND 180
250
0 AND 180

REPETITIONS PERFORMANCE
CATEGORY
3
3
3

A
A
C

Mains Voltage and Frequency: 230VAC, 50 Hz

PERFORMANCE CATEGORY EXPLANATION


Criterion A - Normal Performance within specified limits.
Normal status as monitored. Maintains call and is able to make call upon
completion.
Criterion B - Temporary degradation occurred during the test. Normal
performance restored and no change of operating state or stored data after the
test.

Criterion C - Temporary loss of function occurred that is self-recoverable or


temporary loss of function, which requires operator intervention.
Temporary loss of function; loses call. Function restored and is able to make call
after test.

Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873


(603) 887 3903 Fax (603) 887 6445
www.complianceworldwide.com

Page 31 of 33

Test Number - 137-11


Siemens Enterprise Communications, Inc.
OpenScape 50i - DP14E

11.4 TEST EQUIPMENT


Equipment

Serial #

Verification Due

Keytek CEMaster

9704225

12/01/2011

All equipment used for testing has been calibrated according to the methods and
procedures defined by the National Institute of Standards and Technology (NIST).

Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873


(603) 887 3903 Fax (603) 887 6445
www.complianceworldwide.com

Page 32 of 33

Test Number - 137-11


Siemens Enterprise Communications, Inc.
OpenScape 50i - DP14E

11.5 VOLTAGE DIPS AND INTERRUPTS PHOTO

Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873


(603) 887 3903 Fax (603) 887 6445
www.complianceworldwide.com

Page 33 of 33