You are on page 1of 5

BFL.GTP.PT.11.

0
Guaranteed Technical Particulars

B Fouress (P) Limited

Page No : 1 of 5

Potential Transformer

Sl no

Description

Type of Potential Transformer

Duty

Name of the Manufacturer

Manufacturer Type and designation

Applicable standards

Designed Ambient Temperature.

To be filled in By supplier

Basic Rating
7

Rated Voltage with Variation Limits

Highest System Voltage

Rated Frequency with Variation limits

10

No of Cores
Core 1

11

Rated Primary Voltage

12

Rated Secondary Voltage

13

Rated Transformation ratio

14

Accuracy Class.

15

Rated Output ( Burden ) in VA,

16

Magnetising current

17

Rated Voltage Factor


a.Continuous
b.Short Time

18

Vector Group

19

Particular of Core
a.Type
b.Material of Core
c.Flux Density at.
i. Rated Current.
ii. 1.5 times rated primary current.

20

Thickness of steel lamination

21

Lamination Material

22

Short time Current Rating Thermal

a.

One minute

b.

Three minute

23

Short time Current Rating Dynamic

Core 2

Core 3

BFL.GTP.PT.11.0
B Fouress (P) Limited

Page No : 2 of 5

Guaranteed Technical Particulars


Potential Transformer

a.

One minute

b.

Three minute

24

Details of winding

a.

Name of the manufacturer

b.

Material

c.

Applicable standard

d.

Type of Winding

e.

Method of Connection

Second

Core 1
f.

No of turns

g.

Cross section area

h.

Resistance corrected to 75 O C
i. Primary Winding
ii. Secondary Winding

i.

Current density in primary winding

j.

Current Density in secondary Winding

k.

Short time thermal rating for

1.

One second.

2.

Three Second.

l.

Details of winding insulation


i.Class of Insulation
ii.Type of Insulation

m.

Instrument safety factor for metering winding

n.

Secondary limiting voltage

o.

Partial discharge level (PC)

p.

Ratio interference voltage


With terminal connector mounted
Under test conditions (microvolts).

q.

Visual corona extinction voltage (kV rms).

r.

Variation in ratio and phase angle error due to variation


in
i. Voltage by 1 %

ii. Frequency by 1 Hz
Maximum ratio error with rated burden and 5% normal
s.
primary voltage (%)
Maximum phase angle error with rated burden and 5%
t.
normal primary voltage (%)
Temperature rise at 1.1 times rated voltage with rated
u.

Core 2

Primary Winding

Core 3

Core 4

BFL.GTP.PT.11.0
B Fouress (P) Limited

Guaranteed Technical Particulars


Potential Transformer

burden
25

Bushing Insulators

a.

Make of the Bushing

b.

Type and designation.

c.

Applicable Standard

d.

Material of the Bushing.

e.

Voltage class

f.

Current Rating.

g.

Power frequency withstand voltage

h.

Impulse withstand voltage

i.

Switching surge withstand voltage

j.

Visible corona discharge voltage


Pitch circle diameter and drilling of flange

k.

length of insulator (overall)

l.

Cantilever strength of Bushing in KN

m.

Electrostatic capacity of complete bushings

n.

Range of arcing horn gap settings

o.

Total Creepage Distance

p.

Protected creepage distance

26

Insulation level

a.

Highest system voltage

b.

One minute power frequency dry withstand voltage( kv


rms)

c.

One minute power frequency wet withstand


voltage(kVrms)

d.

1.2 / 50 micro second impulse withstand voltage (KV rms)

e.

One minute power frequency withstand voltage on


secondary

f.

Maximum Radio interference voltage


27

Temperature rise (c) at rated continuous thermal over


max ambient O C

a.

Winding

b.

Oil at Top

c.

Exposed current carrying parts

28

Temperature rise at short time thermal current

29

Tank and secondary terminal box details

a.

Material

Page No : 3 of 5

BFL.GTP.PT.11.0
B Fouress (P) Limited

Guaranteed Technical Particulars


Potential Transformer

a.

Thickness of the Sheet

b.

Size of the Tank

c.

Details of the Mounting Plate

b.

Paint

a.

Type of Painting

b.

Paint Shade

1.

Interior

2.

Exterior

c.

Secondary terminal arrangement


i. No of Terminals
ii. Size of Terminals
iii. Whether suitable for Ring type Lugs.

30

Oil

a.

Name of the Manufacturer

b.

Applicable standard

c.

Break down voltage

d.

Quantity of Oil

e.

Weight of Oil

31

Oil level indicator

a.

Name of the manufacturer

b.

Type

c.

Size

32

Gasket

a.

Name of the manufacturer

b.

Material

c.

Thickness
33

Pressure relief device

a.

Name of the manufacturer

b.

Type

c.

Applicable standard
34

Weights

a.

Weight of the winding

b.

Weight of the core

c.

Weight of the insulator bushing

d.

Weight of the Oil

e.

Total weight of the CT.

Page No : 4 of 5

BFL.GTP.PT.11.0
B Fouress (P) Limited

Guaranteed Technical Particulars


Potential Transformer

35
i.

Over all dimensions of CT.


Length

ii. Depth
iii. Height
Mounting details.

f.
36

Shipping Details

a.

Weight of Heaviest package

b.

Dimension of largest Package

i.

Length

ii.

Depth

iii.

Height

Page No : 5 of 5