You are on page 1of 13

3/28/2016

AerconAACAutoclavedAeratedConcrete

CallAERCON:18008303171|Email:info@aerconaac.com|3701CR.544East|HainesCity,Florida33844
AutoclavedAeratedConcrete
Espaol
Facebook
LinkedIn
Home
Introduction
General
WhatisAerconAAC
WhatGivesAERCONtheCompetitiveEdge
Applications
AERCONBenefitsandAdvantages
OtherGreatBenefitsandAdvantages
Overview
AERCONBuildingSystems
StandardJointProfiles
Installation
PropertiesofAERCONProductsInstallation
BlockProducts
StandardsandApprovals
Ecology
Economics
General
InitialCapitalCosts
LifeCycleCosts
FireResistance
General
FireRatedWallSystems
FireRatedFloorandRoofSystems
FireRatedJointSystems
FireRatedThroughWallPenetrationSystems
ThermalEfficiency
BasicPrinciples
EquivalentRvalue
FloridaEnergyCode
ArchitecturalDesign
General
DesignFlexibility
Compatibility
MoistureBehavior
ExteriorSurfaceTreatment
InteriorSurfaceTreatment
http://www.aerconaac.com/technicalmanualfireresistance.html

1/13

3/28/2016

AerconAACAutoclavedAeratedConcrete

AcousticPerformance
StructuralDesign
General
FloorPanels
RoofPanels
DiaphragmAnalysis
NonLoadBearingWallPanels
LoadBearingVerticalWallPanels
BlocksandLintels
Fasteners
Notation
Installation
4"x24"x24"ShaftWallInstallation
3"x48"x24"ShaftWallInstallation
GeneralInstallationGuidelines
Delivery&StagingofMaterials
InstallingAerconBlock
InstallingAerconVerticalWallPanels
InstallingAerconHorizontalWallPanels
InstallingAerconFloorandRoofPanels
ConstructionDetails
FloorandRoofPanels
NonLoadBearingWallPanels/WallPanelConnections
LoadBearingVerticalWallPanels
BlocksandLintels
Electrical/PlumbingInstallation
HomeTechnicalManualIntroductionOverviewEconomicsFireResistanceThermalEffciencyArchitechural
DesignStructuralDesignInstallation4"x24"x24"ShaftWallInstallation3"x48"x24"ShaftWall
InstallationConstructionDetails

TechnicalManual
FireResistance
ViewFireResistance.PDF
Show:
General
FireRatedWallSystems
FireRatedFloorandRoofSystems
FireRatedJointSystems
FireRatedThroughWallPenetrationSystems

General

AdobeAcrobat
ConvertwebpagetoPDF...
AddtoexistingPDF...
VisitDocumentCloud

OpenPDFinAcrobat

Preferences...
AERCONproductsarenoncombustible.Sointhecaseoffire,AERCONwillhelppreventthespreadofthefireto
otherrooms.Whenexposedtoafire,notoxicgasesorvaporsareemittedfromAERCONproducts.

AERCONsystemssuchasinteriorandexteriorwalls,andfloorandroofpanelsprovidetremendousfirerated
assembliesinalltypesofbuildings.Singlefamilyandmultifamilytownhousescommercial,publicandindustrial
buildingsallbenefitfromtheextraordinaryfireratingsprovidedbyAERCONproducts.Auniquepropertyof
AERCONisthatitcontainswaterincrystalline

form,whichactsasaheatsink,absorbingheatandchangingintosteam.AERCONsporousstructureallowsthis
steamtoescapewithoutcausingsurfacespalling.
http://www.aerconaac.com/technicalmanualfireresistance.html

2/13

3/28/2016

AerconAACAutoclavedAeratedConcrete

Thefollowingsectionsdescribethenumerousanddiversesystemswhichcanbeusedinfireratedapplicationsto
providesuperbprotection.
AERCONsystemscanbeconstructedusingblocks,panelsoracombinationofproducts.Sincethesearesolid
elementswithverysimpleconnectiondetails,theeaseofconstructionhelpstoensureamonolithic,highlyfire
resistantassembly.

Forthespecificdetailsandrequirementsofeachsystemthatisavailable,pleaseseethereferenceddocument.
(AccesstotheULreferencesiscurrentlyavailablethroughtheirwebsiteatwww.ul.com.Fromtheirhomepage,
selectCertificationsandsearchbycompanyname:AERCON.)
Walls,FloorsandRoofSystems

ThroughPenetrationSystems

JointSystems

http://www.aerconaac.com/technicalmanualfireresistance.html

3/13

3/28/2016

AerconAACAutoclavedAeratedConcrete

FireRatedWallSystems
EnergyConservation
Duetotheirexceptionalperformancewhenexposedtofire,AERCONproductsaretheidealsolutionfora
multitudeofsuperstructuresandinteriorspacesthatrequireafirerating.Whetheritsblocksorpanels,AERCON
canbeusedasfireseparationwallsbetweentownhouses,condominiums,apartmentsandothermultifamily
dwellings.AERCONisalsoappropriateforhotels,motels,dormitories,assistedlivingfacilities,hospitals,prisons,
jails,detentioncenters,schools,

movietheatres,exitcorridors,shaftwalls,andstairwellwalls.Industrialusesincludeelectricalrooms,mechanical
rooms,computerrooms,communicationsequipmentrooms,flammablematerialsstorage,documentstorage,
warehouses,laundryrooms,boilerrooms,maintenanceshops,emergencygeneratorrooms,productioncontrol
rooms,sprinklercontrolroomsandincineratorrooms.
AERCONproductscanbeusedastheprimaryloadresisting
structuralsysteminadditiontobeingusedascladdingtoincreasethefireratingofstudwallsandtoprotectother
materialssuchasstructuralsteel.
Loadbearingornonloadbearinginteriororexteriorsinglestoryormultistoryifyouhaveafirehazard,
AERCONcanprovideasystemtocontainit.UseAERCONtorestrictafirefromspreadingortoprotectvaluables
fromanexternalfire.Whensafetyisanissue,AERCONtakestheheat.

http://www.aerconaac.com/technicalmanualfireresistance.html

4/13

3/28/2016

http://www.aerconaac.com/technicalmanualfireresistance.html

AerconAACAutoclavedAeratedConcrete

5/13

3/28/2016

AerconAACAutoclavedAeratedConcrete

AERCONBlockWall4HourRireRating(ANSI/UL263)

http://www.aerconaac.com/technicalmanualfireresistance.html

6/13

3/28/2016

AerconAACAutoclavedAeratedConcrete

FireTestWallTemperaturesfor8"LoadBearingBlockWall(ANSI/UL263)

AERCONFireSeparationWallPartitions4HourFireRating(ASTME119)

http://www.aerconaac.com/technicalmanualfireresistance.html

7/13

3/28/2016

AerconAACAutoclavedAeratedConcrete

FireTestWallTemperaturesfor4"WallPartitions(ASTME119)

FireRatedFloorandRoofSystems
Inmultistoryconstruction,AERCONfloorpanelsareamultifunctionalelement.Inadditiontoservingasthe
structuralfloorsystem,AERCONfloorpanelsalsoprovideanyfireprotectionthatmayberequired.Theintegral
fireratingofAERCONfloorpanelseliminatestheneedforanyancillarymaterialsorcoatingstoachieveafire
resistantassembly.Abasic6inchthickfloorpanelsystemhasa4hourfireresistancerating

perULK909.Foranassemblytobeconsideredrestrainedmerelyrequiresthataconcreteringbeam,also
referredtoasabondbeam,bepouredaroundtheperimeterofthefloorsystem,withtheinclusionofreinforcing
steelintheringbeamandinthegroutedkeyjoints.Sincetheconcreteandgroutpoursareintegralcomponentsof
thestructuralsystem,oncetheyarecompleted,soisthefireratedassembly.Noadditionalmaterials
http://www.aerconaac.com/technicalmanualfireresistance.html

8/13

3/28/2016

AerconAACAutoclavedAeratedConcrete

noadditionallabor.Onesystemexceptionalfirerating.
JustasAERCONfloorpanelsprovidesuperbfireresistance,sotoodoAERCONroofpanels.Manufacturedand
installedjustlikefloorpanels,AERCONroofpanelshavea4hourfireresistanceratingperULP932.Whetherthe
fireisaboveorbelowtheroof,AERCONroofpanelsprovidethepeaceofmindthatyourstructureisfireresistant.

AERCONReinforcedFloor/RoofPanels4HourFireRating(ANSI/UL263)

FireTestPanelTemperaturesfor8"Floor/RoofPanels(UL263)

http://www.aerconaac.com/technicalmanualfireresistance.html

9/13

3/28/2016

AerconAACAutoclavedAeratedConcrete

FireRatedJointSystems
Wheneverfireratedelementsabutoneanother,alinearjointorgapisusuallycreated.Inordertomaintainthe
integrityoftheoverallassembly,afireratedsystemmustbeusedtosealthejointorgap.Therearefourprimary
configurationsofjointsasillustrated.
Thebasicstandardusedtoinvestigateproducts

thatareusedinjointsystemsisANSI/UL2079,TestsforFireResistanceofBuildingJointSystems.Thehourly
ratingsapplyonlytothecompletesystems.Individualcomponentsaredesignatedforuseinaspecificsystemto
achieveaspecifiedrating.Eachofthejointsystemsidentifiedareclassifiedasdynamic,thatis,having
movementcapabilities.
Alljointsystemsaretestedattheirmaximumjointwidth.Theratingsforthejointsystemsinstalledinwallsapply
wheneitherfaceofthewallisexposedtofire.Theratingsforjointsystemsinstalledinafloororroofapplywhen
theundersideorceilingsurfaceisexposedtofire.

http://www.aerconaac.com/technicalmanualfireresistance.html

10/13

3/28/2016

AerconAACAutoclavedAeratedConcrete

FireRatedThroughWallPenetrationSystems
Wheneveracommoditysuchaspipingorelectricalwiringmustpassthroughafireratedelement,acircularor
rectangularjointorgapisusuallycreated.Inordertomaintaintheintegrityoftheoverallassembly,afirerated
systemmustbeusedtosealthejointorgap.Afirestopsystemisaspecificconfigurationofitemsthatconsistsofa
wallorfloorassembly,anitemthatpenetratesthatwallorfloorassembly,andthematerialsdesignedtoprevent
thespreadoffirethroughtheopeningthatiscreatedaroundthepenetratingitem.Therearecurrentlythree
throughpenetration

firestopsystemsthatcanbeutilizedwithAERCONwallsandfloors.Theseareillustratedtoshowthevarious
itemsassociatedwitheachsystem.
ThebasicstandardusedtoinvestigateproductsthatareusedinthroughpenetrationsystemsisANSI/UL1479,
FireTestsofThroughPenetrationFirestops.ThisstandarddefinesthecriteriaforhourlyFandTratingsfor
firestopsystems.TheFratingcriteriaprohibitsflamepassagethroughthesystemandrequiresacceptablehose
streamtestperformance.TheTratingcriteriaprohibits
flamepassagethroughthesystemandrequiresthemaximumtemperaturerise(onthesidewhichisnotexposedto
thefireduringtesting)to325Fabovethestartingtemperatureandalsorequiresacceptablehosestreamtest
performance.Theratingsforfirestopsystemsinstalledinwallsapplywheneitherfaceofthewallisexposedto
fire.Theratingsforfirestopsystemsinstalledinafloororroofapplywhentheundersideorceilingsurfaceis
exposedtofire.

http://www.aerconaac.com/technicalmanualfireresistance.html

11/13

3/28/2016

AerconAACAutoclavedAeratedConcrete

Gototopofpage

ContactUs
AERCONAAC
3701CR.544East
HainesCity,Florida33844
Phone:18008303171
Fax:18634226361
Email:

Manufacturing
Block
Lintel
VerticalLoadBearingPanels
VerticalNonLoadBearingPanels
HorizontalCladdingPanels
FloorPanelSystems
RoofPanelSystems

Projects

http://www.aerconaac.com/technicalmanualfireresistance.html

12/13

3/28/2016

AerconAACAutoclavedAeratedConcrete

SignUpForNewsletter
Putyouremailandclickontheenvelopebutton.
Youremail

AERCONAAC|Allrightsreserved2014|mHerningwEbdEsigns.com
Facebook
LinkedIn
Google+

http://www.aerconaac.com/technicalmanualfireresistance.html

13/13

You might also like