You are on page 1of 4

Pressure

Flow

Humidity

MicaFlex
Transmitters and controllers for pressure, flow
humidity and temperature
Laboratory ventilation

MicaFlex

MicaFlex

Analogue pressure & flow transmitter.

Digital pressure & flow transmitters/controllers/supervision and


humidity & temperature
transmitters.

MF-P

Differential pressure transmitter with


adjustable damping in four steps.

The new programmable serie is


designed to meet very high
demands for safety and
accuracy.
Every unit is fully programmable
from the outside of the front cover
with the keypads.
The two line display with 16 signs
on each line is easy to read and
understand.

MF-PD

Differential pressure transmitter with display


and adjustable damping in four steps.

You can choose between several


standard text menus for the
display.
All units with built in pressure
sensor are easy to zero set and
recalibrate by the keypads.

MF-PFT
Differential pressure transmitter
and controller
Programmable differential pressure
transmitter for pressure and flow
measurement and control.
One of the outputs could be used for
controlling.

General data:

MF-FD

Differential pressure transmitter with flow


linearized display and output.
Easy flow display adjustment.
Adjustable damping in four steps.

Standard ranges:
-50...+50 Pa
0...100 Pa
0...200 Pa
0....500 Pa
0...1 kPa
0...2 kPa
0...5 kPa
(Other ranges are available on
request)
Certificate of calibration included
Power:
Output:

24VAC/18...32VDC
0/2...10VDC
0/4...20 mA

Accuracy:
< 0,5 % of pressure range

Transformer:
24, 115, 230 VAC
(not supported by all models)
Casing:
ABS-plastic IP 65

General Data:
Pressure ranges: See digital series
Power:
24VAC/1832VDC
Output:
0..10 VDC/4..20 mA
Accuracy:
< 1% Fs
Casing:
ABS-plastic IP 65
Accessories:
Transformer
24, 115, 230 VAC

Accessories:
Analogue & Digital series

Panel mounting kit


Manifold valve
DIN rail mounting kit
Pressure connection kit VR-DR

MF-PFA
Pressure- & flow supervision
Programmable differential pressure
transmitter for measurement, control
and supervision of pressure and flow
in Clean room- and similar applications.
Two outputs for voltage or mA.
One of the outputs could be used for
controlling.
Two voltage free relay contacts
(24 VAC, 5 Amp) for high/low-alarm.
Programmable time delay.
Acoustic alarm with reset functions.

MF-PFC

MF-PFCA

MF-MDU

Controller

Controller with alarm

Display

Programmable differential pressure


controller with built in sensor for
pressure and flow control. Two output terminals for volt or mA. One for
actual value and one for control output. The controller mode is specially
developed for pressure and flow control in different ventilation applications. SPC-input ( 0/2...10 VDC,
0/4...20 mA) for e.g. outdoor temperature compensation. Digital input for
start, stop or change between two
setpoints.

Programmable differential pressure


controller with built in sensor for
pressure and flow control. Two output terminals for volt or mA. One for
actual value and one for control output. SPC-input ( 0/2...10 VDC,
0/4...20 mA).
Digital input for start, stop or change
between two setpoints.
Two voltage free relay contacts (24
VAC, 5 Amp) for high/low alarm.
Programmable time delay.
Acoustic alarm with reset functions.

Programmable display unit with two


analogue in- and outputs. Volt or
mA. Several standard textmenus for
different applications.
Supply voltage for e.g. 2-wire-sensor
15 VDC, max. 50 mA.

MF-PFX

MF-HTT

MFS

Controller

Humidity- & temperature transmitter Flowsensor

Programmable controller for external


sensor for pressure and flowcontrol.
Two output terminals for volt or mA.
One for actual value and one for
control output. The controller mode
is specially developed for pressure
and flow control in different ventilation applications.
SPC-input ( 0/2...10 VDC, 0/4...20
mA) for e.g. outdooor temperature
compensation. Power supply for
2-wire sensors 15 VDC, max. 50 mA.
Digital input for start, stop or change
between two setpoints.

Programmable humidity and temperature transmitter with room or duct


mounted sensors. Two output terminals for voltage or mA.
Measures RH and temperature and
includes a calculating program for
dew point and mixing ratio (g/kg).
The analogue outputs selectable for
optional parameter.

Power:
Input:
Output:

24VAC/1832VDC
0/210 VDC,
0/420 mA
0/210 VDC,
0/420 mA

Patented, self-averaging flow sensor


for all kinds of ventilation ducts.
The average of air flow is measured
across the whole length of the sensor.
Gives a 2.5 times higher differential
pressure than Prandtl tube measuring.
Measurement error < 3%.
Easy to install in existing ducts.
Lengths from 100...2500 mm.

Exhaust air

Control unit
MF-FHC

Actuator
HSA-24SR

Power
supply

Measure
connection

Alarm

Micaflex system for fume


hood face velocity control

MicaFlex

Operator monitor
MF-FHM

0.5 m/s

Flow
Normal
Normal

Caution

Alarm

NORMAL
FLOW

HIGH
FLOW

LOW
FLOW

PGM

TEST
RESET

ESC

Keypad functions in programming mode

Operator Monitor

FHM

The system is developed for continuous measuring, control and


supervision of the face velocity of the
fume hood sash opening and by that
guarantee the safety for the operator
and laboratory personel.
The control also offers the lowest
possible energycost when the inflow
is kept at lowest possible value of
0,5 m/s independant of the fume
hood sash opening.
MicaFlex fume hood system consists
of;
p Operator monitor FHM
p Control unit FHC with built in
sensor
p Actuator HSA-24SR
p Damper

FHM has a two-line display with 32


signs. During operation actual face
velocity is indicated in m/s together
with the selected function: Normal
flow, High flow, Low flow and at
alarm, Alarm high/low.
Function
Three LEDs indicates alarmstatus:
The sensor measures the pressure
Normal, Caution and Alarm
difference between the fume hood
The mode of operation is selected by
and laboratory. The outputsignal is
the four keypads:
linearized to a flowlinear signal for
0...2,0 m/s. The control is performed 1. Normal flow
2. High Flow (forced flow)
very rapidly. A change of the fume
3. Low flow (minimized flow for
hood sash opening requires only
setting etc)
about 1 second until the correct hood
4.
Test/Reset
functiontest of alarm
face velocity is reestablished.
and reset of alarm

System example
Balanced ventilation by control
of make up air ventilation

PFCA

Exhaust air

MFS

HSA-24SR

Make up
air ventilation
Fume hood

Fume hood

HSA-24SR

PFCA
Supply air
MFS

Operator monitor FHM

Function
Exhaust air
PFCA measures the flow via MFS
flow sensor. When the exhaust air
falls below min. flow the make up
air ventilation damper is controlled
to achieve set flow. At increasing
exhaust air the make up air ventilation damper closes until the exhaust air flow exceeds the min. set
flow.
PFCA gives alarm at high/low flow.
The setpoint for make up air ventilation may be influenced by
temperaturetransmitter, controller or
other sensor e.g. CO2, Volt/mA.
Supply air
The actual value from the exhaust
air controller forms the set point for
the control of supply air.
PFCA controls the damper to
balance or set offset.
PFCA supervises min. or max. flow
as well as the difference between
supply air- and exhaust air-flow.
Alarm is achieved after set time
delay.

Distributor:

AB Micatrone, Dalvgen 8, SE-169 56, SOLNA, SWEDEN. Tel: +46 8 470 25 00 Fax: +46 8 83 27 80, www.micatrone.se