You are on page 1of 2

environmental Sensors

6%2)3).$5342)%3

TD/TF/TG

INSTALLATION GUIDE

TD/TF/TG

Duct Mounted Temperature Sensors

TG
Installers Specifications

TF

TD

/05*$&
t
t
t

t
t

5IJTQSPEVDUJTOPUJOUFOEFEGPSMJGFPSTBGFUZBQQMJDBUJPOT
%POPUJOTUBMMUIJTQSPEVDUJOIB[BSEPVTPSDMBTTJmFEMPDBUJPOT
3FBEBOEVOEFSTUBOEUIFJOTUSVDUJPOTCFGPSFJOTUBMMJOH
UIJTQSPEVDU
5VSOPBMMQPXFSTVQQMZJOHFRVJQNFOUCFGPSFXPSLJOHPOJU
5IFJOTUBMMFSJTSFTQPOTJCMFGPSDPOGPSNBODFUPBMMBQQMJDBCMFDPEFT

Enclosure

Probe Length Sensor Type

Output Cal Certificate

D = Duct
B = 4" (102mm)
F = Duct w/
C = 6" (152mm)
mounting box D = 8" (203mm)
G = Duct w/ water E = 12 (305mm)
resistant housing F = 18 (457mm)
G = 24 610mm)
K = 36 (914mm)

Z205467-0B

PAGE 1

*Room temperature error documented on each unit.

quick install
1. Drill a 3/8 diameter hole for the sensor probe.
2. Insert probe into duct.

Product Identification
T

Wiring
22AWG; 2-wire:RTD Thermistor, 4-20mA; 3-wire: Voltage output models
Probe
Stainless Steel
Test Pressure
200psi
Linitemp:
Input Power
5 to 30VDC
Output
1A/C or 10mV/C
Operating Temperature
-25 to 105C (-13 to 221F)
Accuracy Calibration Error:
1.5C (35F) typical; 2.5C (37F) max. at 25C (77F)*
Error over Temperature:
1.8C typical (35F); 3.0C (34F) max.

over 0 to 70C (32 to 158F) range

2.0C (35F) typical, 3.5C (38F) max.

over -25 to 105C (-13 to 221F) range

3. Secure the junction box housing (TF/TG) or mounting flange (TD) to outer surface
of duct using self-tapping screws provided.
4. Wire as shown (see Wiring section).

B = 100R Platinum, RTD = Resistive out 0 = None


C = 1k Platinum, RTD
1 = 1 point
D = 10k T2, Thermistor
Cal validation
E = 2.2k, Thermistor
2 = 2 point
F = 3k, Thermistor
Cal validation
G = 10k CPC, Thermistor
H = 10k T3, Thermistor
J = 10k Dale, Thermistor
K = 10k w/11k shunt, Thermistor
M = 20k NTC, Thermistor
N = 1800 ohm, Thermistor
P = 10mV/C, Linitemp
R = 10k US, Thermistor
S = 10k 3A 221B, Thermistor
T = 100k, Thermistor
U = 20k D, Thermistor

2009 Veris Industries USA 800.354.8556 or 503.598.4564 / support@veris.com

01091

Alta Labs, Enercept, Enspector, Hawkeye, Trustat, Veris, and the Veris V logo are trademarks or registered trademarks of Veris Industries, L.L.C. in the USA and/or other countries.

6%2)3).$5342)%3

Dimensions

Wiring
TD Model

1.5"
(38 mm)

Orange

Thermistor
RTD

1.1"
(28 mm)

2"
(51 mm)

INSTALLATION GUIDE

TD/TF/TG

0.25"Dia.
(6 mm)
L

Linitemp

Orange
ORANGE V+ (15V)
WHITE SIGNAL
BLUE COMMON/GND

NOTE: All linitemp units are standard 3-wire 10m V/C. For 1 A/C (2-wire)
connect +15V (orange) and (white) signal wire. The (blue) wire is not
connected.

TF Model
2.3"
(59 mm)

3-Wire 10m V/C


CONTROLLER
+15v

4.3"
(109 mm)

0.25"Dia.
(6 mm)
L

Analog IN
Common

WHITE (SIGNAL)
MON/G
BLUE (COM

TEMP SENSOR
ND)

CONTROLLER

0.7"
(18 mm)

+15v
0.25" Dia.
(6 mm)
Foam Gasket
2.5" x 2.5"
(62 mm x 62 mm)

Analog IN
Common

0.25" Dia.
(6 mm)

4.6"
(117 mm)

V+ (15V)

2-Wire 1 A/C

TG Model

2.9"
(74 mm)

ORANGE

ORANGE

V+ (15V)

WHITE (SIGNAL)
BLUE (NO

TEMP SENSOR

CONNECT)

2.0"
(51 mm)

Z205467-0B

PAGE 2

2009 Veris Industries USA 800.354.8556 or 503.598.4564 / support@veris.com

01091