Standard welded wire mesh for concrete reinforcement

Page 1 of 2

STANDARD WELDED WIRE MESH FABRIC FOR CONCRETE REINFORCEMENT

SPECIFICATIONS
1) STANDARD MESH FOR CONCRETE REINFORCEMENT
The production of mesh reinforcement complies to BS 4483. Mesh is
produced from cold reduced deformed steel wires according to BS 4482.

a) Mechanical Properties
 Specified characteristic strength: 460 N/mm

 Tensile Strength: min 510 N/mm. In addition either the tensile

strength recorded in the tensile test shall be at least 5% greater


than the recorded yield strength or alternatively the minimum
elongation shall be not less than 12% measured on a gauge length
of 5do.

 Shear strength of the weld: The shearing load required to produce

failure of a welded intersection shall be not less than 0.25 A fy,


where A is the nominal cross-sectional area of the smaller wire at
the welded intersection and fy is the characteristic yield stress of the
wire (460 N/mm).

b) Chemical composition of steel


Carbon C: max 0.25%
Sulphur S: max 0.060%
Phosphorous P: max 0.060%
Carbon Equivalent Value Ceq: max 0.42%
Where Ceq = C + Mn/6 + (Cr+V+Mo)/5 + (Cu+Ni)/15

TABLE I - STANDARD MESH FABRIC FOR CONCRETE REINFORCEMENT


No.

Types

Wire Spacing

Wire Diameter

Main mm

Cross mm

Main mm

Cross mm

Sheet
Dimensions/m

Weight per
sheet kg/pc

A98

200

200

16.7

A142

200

200

24.1

A193

200

200

A252

200

200

A393

200

200

10

10

67.1

B503

100

200

64.7

B785

100

200

10

89.1

A98*

200

200

A142*

200

200

10

A252*

200

200

11

A393*

200

200

10

10

12

Q92

150

150

4.2

4.2

13

Q131

150

150

14

Q188

150

150

15

Q257

150

150

7/5()

39.7

16

R92

150

250

4.2

4.2

12.8

http://www.domoplex.com.cy/p1_concrete.htm

32.8
2.15 X 5.00

1.80 X 3.00

1.75 X 3.00

43.0

8.3
12.0
21.0
32.9
15.9
22.5

2.15 X 5.00

32.4

8/19/2011

Standard welded wire mesh for concrete reinforcement

STEEL

Page 2 of 2

Cold reduced, high tensile, deformed, according to BS 4482

Note 7/5(): Mesh Type Q257 is produced with cross wires Y7/150mm. Longitudinal wires
in the middle section of the sheet are again Y7/150mm, while in the marginal areas, on
either side, the longitudinal wires are Y5/150mm (3 No Y5mm on each side). This is saving
weight at the side overlapping areas.
*continued
No.

Types

Weight per mkg/m

Sectional Area
Main mm/m

Overhangs

Cross mm/m

A98

1.54

98

98

A142

2.22

142

142

A193

3.02

193

193

A252

3.95

252

252

A393

6.16

393

393

B503

5.93

503

252

B785

8.14

785

252

A98*

1.54

98

98

A142*

2.22

142

142

10

A252*

3.95

252

252

11

A393*

6.16

393

393

12

Q92

1.48

92

92

13

Q131

2.09

131

131

14

Q188

3.01

188

188

15

Q257

3.69

257

257

16

R92

1.19

92

55

STEEL

Main mm

Cross mm

100 / 100

75 / 75

100 / 100

25 / 25

100 / 100

125 / 75

100 / 100

75 / 75

100 / 100

25 / 25

125 / 125

25 / 25

Cold reduced, high tensile, deformed, according to BS 4482

Other products
 NON-STANDARD AND BENT WELDED WIRE MESH FOR CONCRETE REINFORCEMENT
 STANDARD WELDED WIRE MESH FABRIC FOR FENCING
 WELDED WIRE MESH FABRIC FOR STIRRUPS REINFORCEMENT
 COLD REDUCED STEEL WIRE FOR THE REINFORCEMENT OF CONCRETE
 GALVANISED FENCING WELDMESH IN ROLLS

http://www.domoplex.com.cy/p1_concrete.htm

8/19/2011

You might also like