You are on page 1of 336

2014 Prod Cat Canadian Cover_Mitsubishi 30/04/2014 13:34 Page 1

2014 Product Catalogue

Living Environmental Systems


2014 Product Catalogue

Sales Contacts

Corporate Sales

Birmingham

Bristol

Manchester

London South Region

London Central Region

Tel: 01454 202050


Fax: 01454 202900

Tel: 0121 741 2800


Fax: 0121 741 2801

Tel: 0870 3000 070


Fax: 0870 3000 080

Tel: 0207 928 6810


Fax: 0207 928 6569

Tel: 01737 387170


Fax: 01737 387189

Leeds

Tel: 01506 444960


Fax: 01506 444961

Tel: 0161 866 6060


Fax: 0161 866 6081

Tel: 01924 207680


Fax: 01924 207 699

Scotland

London North Region


Tel: 01707 282480
Fax: 01707 282481

Ireland

Tel: +353 (0)1 419 8800


Fax: +353 (0)1 419 8890

Telephone: 01707 282880


MELSmart Technical Services: 0161 866 6089
Technical Help - option 4
Warranty - option 3
Training - option 6 followed by option 1

email: livingenvironmentalsystems@meuk.mee.com
website: livingenvironmentalsystems.mitsubishielectric.co.uk
website: recycling.mitsubishielectric.co.uk
UNITED KINGDOM Mitsubishi Electric Europe Living Environmental Systems Division
Travellers Lane, Hatfield, Hertfordshire, AL10 8XB, England
General Enquiries Telephone: 01707 282880 Fax: 01707 278881
IRELAND Mitsubishi Electric Europe Westgate Business Park, Ballymount, Dublin 24, Ireland
Telephone: Dublin (01) 419 8800 Fax: Dublin (01) 419 8890 International code: (003531)
Country of origin: United Kingdom Japan Thailand Malaysia. Mitsubishi Electric Europe 2014. Mitsubishi and Mitsubishi Electric are trademarks of Mitsubishi Electric Europe B.V. The company reserves the right to make any variation
in technical specification to the equipment described, or to withdraw or replace products without prior notification or public announcement. Mitsubishi Electric is constantly developing and improving its products. All descriptions, illustrations,
drawings and specifications in this publication present only general particulars and shall not form part of any contract. All goods are supplied subject to the Companys General Conditions of Sale, a copy of which is available on request.
Third-party product and brand names may be trademarks or registered trademarks of their respective owners.
Note: The fuse rating is for guidance only. Please refer to the relevant databook for detailed specification. It is the responsibility of a qualified electrician/electrical engineer to select the correct cable size and fuse rating based on current regulation
and site specific conditions.

Printed in April 2014

SAP No.256903

Designed by Square Bear Ltd 01604 899099. Square Bear Ltd are committed to using FSC certified paper and printers, wherever possible.

LES INTRO PAGES_Layout 1 30/04/2014 14:25 Page 1

Welcome to

Mitsubishi Electric
Living Environmental
Systems

Mitsubishi Electric Living Environmental Systems is a market leader


in providing solutions to cool, heat, ventilate and control our buildings.
As a major manufacturer of some of these pivotal technologies, we hold the UK's energy challenges
close to our heart. We want to help the nation achieve its climate goals; we want to help individuals
and businesses reduce the energy consumption of their buildings, whilst also helping to reduce
their annual running costs.
Founded in 1921, with many of those years spent at
the forefront of the air conditioning industry, we have led
the way in the use of innovative, energy efficient, heat
pump technology. Mitsubishi Electric has evolved, and
today our areas of expertise go way beyond advanced
air conditioning systems that formed the foundation of
our business.
Here in the UK, our Living Environmental Systems division provides
advanced solutions that cool, heat, ventilate and control buildings
in the most energy efficient and cost effective ways possible.
With performance and efficiency central to our business, we
are leading the way to a more sustainable future through high
performance products and controls that maximise comfort,
minimise cost and reduce carbon emissions.
Through our technical expertise, long experience and innovative
product range, we enable buildings everywhere to significantly
improve energy efficiency, reduce running costs and adhere to
increasingly tough legislation.

Air Conditioning
Heating
Ventilation
Controls
Services

Towards a better use of energy in buildings


A strong commitment to the environment remains a long-term goal
of Mitsubishi Electric under its global framework for realising a
sustainable planet - Environmental Vision 2021. In the UK, this
vision translates into our Green Gateway philosophy which is central
to the way we do business. With this initiative, we are seeking to
use our position as a manufacturer of key technologies to increase
awareness and improve energy use in the built environment.
By constantly challenging everyone involved to combat the issues
we all face and encourage constructive dialogue throughout the
industry, we aim to help everyone address their energy use and
to work towards a more sustainable future.
Working within the construction industry in this way and developing
energy efficient cooling, heating and ventilation solutions - all managed
by the most advanced control systems available.

At Mitsubishi Electric we believe we can truly


make a world of difference.

LES INTRO PAGES_Layout 1 30/04/2014 14:25 Page 2

Contents

Air Conditioning

Heating

Ventilation

Controls

Services

Air Conditioning

Air Conditioning

Energy Efficient

Air Conditioning
Systems

The need for air conditioning


Todays commercial buildings are increasingly air tight and filled with heat generating office
equipment and lighting, which presents a problem for anyone trying to maintain a stable
and comfortable internal environment. With buildings accounting for around half of all
UK greenhouse emissions, legislation is demanding higher standards of air quality and
increased energy efficiency.
To reduce the impact of the built environment, the challenge is to find cooling, heating, ventilation and control solutions that
match energy efficiency with complete flexibility of design and control.
Our innovative and pioneering air conditioning systems offer more than double the efficiency levels of 10-15 year old systems
and can also be far more efficient than traditional methods of cooling and heating buildings, resulting in reduced running
costs and lower carbon emissions.
Todays systems can simultaneously heat and cool different spaces to balance energy use across a building and sanitary
hot water can even be supplied from the same system.

1.1.3

1.121
Air Conditioning

AIR
CONDITIONING

Energy Efficient Air Conditioning Systems

1.1.4

Energy Efficient

Air Conditioning
Systems

The benefits of our air conditioning


As a market leader, we pride ourselves in providing high performance and competitive
systems with low running costs.
By utilising heat pump technology, our air conditioning units not only provide cooling, but also heating and often sanitary
hot water. Heat pump technology requires only a small amount of electricity to harvest, upgrade and move heat from one
location to another and providing heating and hot water as part of an integrated air conditioning system is far more efficient
than traditional heating methods such as gas.

Outstanding benefits
Efficient and extensive product range ideal for a variety of buildings, from small retail outlets, up to vast multi-storey
office complexes
Air conditioning units which can upgrade free energy from a range of natural sources including air, ground and water
Our pioneering technology has led the way over the last decade with advances in energy efficiency through inverter
technology, refrigerant and compressor design and control solutions
We measure and report true seasonal efficiency to provide accurate performance data
Dedicated Partner Programme for air conditioning installers
Reliable technical support and training at every step of the way

Energy Efficient

Air Conditioning
Systems

Ideal products that make a world of difference


There are two main types of air conditioning systems; Split-Systems which include
the M Series and Mr Slim series, and Variable Refrigerant Flow (VRF) Systems which
incorporate the City Multi range.
Heating Only solutions
Building on a comprehensive range of heating products, Mr Slim splits and City Multi VRF Heating Only units offer a cost
effective and efficient solution designed to combat challenging legislation and the need to reduce carbon emissions and
running costs. Designed to deliver heat via the air, our full range of air conditioning products can also be adapted with the
use of intelligent controls to run as Heating Only products.

Sanitary Hot Water


Mitsubishi Electrics heat pump boiler can be added to a heat recovery VRF System to utilise waste heat.
The system upgrades this to heat sanitary hot water for bathrooms, showers or kitchens.

Heat Pump Air Curtains


Air Curtains are designed to allow open door trading in retail, hotel and leisure outlets by providing uninterrupted access
for passing trade. They can provide significant energy savings, as they prevent conditioned air escaping from the building.
Rather than deriving warm air from conventional sources such as direct electric heating or low, medium or high pressure hot water,
Air Curtains can be linked to VRF or Split heat pump air conditioning units, which significantly reduces the energy used.

HVRF

HVRF heat recovery outdoor unit

Set to rival traditional cooling and heating,


the new HVRF system delivers optimum
comfort and efficiency, using an innovative
combination of unique 2-pipe technology
and water to provide simultaneous heating
and cooling with heat recovery.
For further information on the HVRF system,
please contact your local sales office.

1.1.5

1.121
Air Conditioning

Hybrid Branch Controller (HBC)

Heat /cool flow and return headers

Water based fan coils

Heat exchangers

DC inverter
water pumps
8 ports

2 and 3 way
control valves
2 refrigerant pipes

AIR
CONDITIONING

Water piping providing heating or cooling simultaneously

Energy Efficient Air Conditioning Systems

1.1.6

Energy Efficient

Air Conditioning
Systems

The Enhanced Capital Allowance Scheme (ECA)


ECA is a Government tax incentive for businesses to invest in specific energy efficient
technologies, such as ours.
Under the scheme, all businesses liable for UK corporation tax are able to claim an Enhanced Capital Allowance on any
qualifying expenditure, meaning businesses can offset the full cost of specific technologies against taxable profits of the
period of the investment. Investment in new and unused plant and machinery qualify.
The scheme is managed by the Carbon Trust, who support businesses keen to save energy and reduce carbon emissions,
through the use of energy efficient equipment and low carbon technologies. The trust has developed a criteria which targets
the top 20% of highest performing heat pumps across the industry.
Mitsubishi Electric has developed a range of highly efficient systems which successfully
qualify for ECA and are registered on the Energy Technology List.
For further information please visit the following website: etl.decc.gov.uk
and click on Mitsubishi Electric in the heat pump category.

Energy Efficient

Air Conditioning
Systems

Solutions that address the ban on R22 refrigerant


From the end of 2014 it will be illegal to use R22 refrigerant*1 to service and maintain
air conditioning, yet there are estimated to be around 750,000*2 systems still in use
that rely on R22.
Many of these building operators remain unaware that whilst their air conditioning will not be illegal to run, it may need
immediate replacement if it requires maintenance involving any degassing of the system. Mitsubishi Electric is urging
everyone involved to plan now on how they will handle the R22 issue.
The continual rise in energy costs also means everyone involved in the built environment is focusing on energy use and
consumption and this is where modern equipment can really help to support replacement.
Mitsubishi Electrics The Case for Replace is full of key facts and viable solutions to help businesses adopt a sensible
approach to the replacement of old air conditioning equipment using the Review, Replace, Recycle ethos. Our specially designed
Audit Tool software allows existing and new systems to be compared to discover the potential benefits of replacement or
upgrade. Looking at the differences in the efficiency of the equipment, the software calculates annual running costs, CO2
emissions, spare parts and labour costs. Many of our product ranges also incorporate our unique Replace Technology
which allows the upgrade of systems using existing pipe work, without the need to apply any special cleaning machines.
For further information please visit the following website: replace.mitsubishielectric.co.uk

*1 The EC Ozone Regulation (No. 1005/2009) was introduced to control and phase out the remaining uses of all Ozone Depleting Substances (ODS) such as R22 refrigerant. This has led to a total ban on its use for service and maintenance by the
start of the year 2015. ODS can result in greater UV radiation reaching the earths surface which is harmful for humans, animals and plants, leading to increases in skin cancer, cataracts and a reduction in food crop yields. Modern alternatives such as
HFCs, which include R410A, do not have the same ozone depleting potential (ODP).
*2 Mitsubishi Electrics estimate in 2012.

1.1.7

1.121
Air Conditioning

AIR
CONDITIONING

Energy Efficient Air Conditioning Systems

1.1.8

Energy Efficient

Air Conditioning
Systems

Features Key

Swing Vane Mode

Factory charged refrigerant up to 30m

Fresh Air Knockout

Auto Vane Shutter - when unit is switched


off the vane automatically closes

Standard Filter

Branch Duct Knockout

Wide Swing - distributes air laterally


by up to 150

Optional High Efficency Filter

Double Thermostat Function - control


the temp via a sensor in the controller
or the unit (wired remote controllers only)

Long Airflow Mode - particularly suitable


for use in long, narrow spaces

Catechin Filter - improves air quality


and prevents the spread of bacteria
and viruses within the room

Ceiling Soiling Prevention

Infra-red Remote Controller

Air Cleaning Filter - catches dust particles


and contaminates, helping to keep the
air fresh

Replace Technology Available

Optimised Rotary or Scroll Compressor

Anti-Allergy Enzyme Filter - artificial enzyme


catalyst on the filament catches allergens

Refrigerant Volume Check Function

Econo Cool - allows set temperature to be


raised by 2C without any loss of comfort
and a 20% gain in energy efficiency

Nano Platinum Filter - incorporates nanometre


sized platinum-ceramic particles that generate
stable antibacterial and deodourising effects

I-See Sensor

Inverter Control - adjusts performance


to economically match the demand for
heating or cooling

Quick Clean Design

Duty Standby Operation

Auto-Restart

Plasma Quad Filter System

I-Save - recalls the preferred (present)


temperature via a single button

Quiet Operation

Drain Lift Pump - as standard

Demand Control

72 different Airflow Patterns 2, 3 or 4 way discharge

Optional Drain Lift Pump

Noise Reduction

High Ceiling Compatibility through wide flow air outlets

Low Unit Height - minimal intrusion into


occupied space

COP Priority / High Performance Heating

Auto-Changeover

High External Static Pressure

High Sensible

Hot Start - draught prevention

Optional High Static Fan Motor

Heating Only

Energy Efficient

Air Conditioning
Systems

Contents

1.1.9

1.121
Air Conditioning

M Series

1.2

Mr Slim

1.3

Multi-Splits

1.4

City Multi

1.5

Heating Only

1.6

AIR
CONDITIONING

Contents

M Series
Room Air Conditioning

The Adaptable

M Series
Range

Designed to cool or heat small to medium sized spaces, such as retail


units and small offices, the M Series splits range provides a versatile,
yet affordable air conditioning solution.
Quick to install, the range includes one of the quietest units on the market. Also available in
a variety of options, the M Series range fits in wherever its needed. Indoor units can be wall
or floor mounted.

Wall Mount
Systems

Cost effective Classic Inverter series


Inverter series designed to suit popular demand
Stylish Zen indoor series in black, silver or white
Top of the range High COP Inverter series

Floor Mount
Systems

Extremely versatile
Designed for wall installation at floor level
Compact design makes installation easy
3 models available including 2.5kW-5.0kW

New Features
A brand new floor mounted MFZ-KJ25-50 with energy label up to A+++
A brand new wall mounted MFZ-EF25-50 Zen stylish indoor unit design
A new MELCloud solution available for M Series
models using the new Wi-Fi interface (MAC-557IF)

1.2.3

1.121
Air Conditioning

The Adaptable M Series Range

1.2.4

The Adaptable

M Series
Range

Indoor Units
Indoor Model

Wall Mount

Range

Classic MSZ-HJ

Inverter MSZ-SF

Inverter MSZ-GF

Stylish Zen MSZ-EF*2

High COP MSZ-FH

Floor Mount

*1 Multi-split only

Inverter MFZ-KJ

*2 Also available in silver and white

2.0kW*1

2.5kW

3.5kW

5.0kW

6.0kW

7.1kW

The Adaptable

M Series
Range

Ecodesign and Seasonal Efficiency


With buildings accounting for around half of all UK greenhouse emissions, legislation is demanding
increased energy efficiency. The Ecodesign Directive for Energy Related Products (ErP) is focusing on
this area in a bid to reduce overall energy consumption, and to accelerate market transformation to
more energy efficient products.
An air conditioner will vary performance over changing seasons which means calculating seasonal performance is important to ascertain
the true performance of an air conditioning system. The Ecodesign Directive reflects this by setting minimum efficiency requirements and
a new method of measuring performance introduced across the EU and hence new energy ratings are achievable.
The European Standard BS EN14825:2012 sets the seasonal performance calculation for an air conditioning system under 12kW of
which the energy efficiency class for each product specification is shown. For more information visit the website mitsubishielectric.eu/erp
Product design improvements have enhanced the seasonal efficiency, however this may effect nominal COP/EER.

Example:

1.2.5

1.121
Air Conditioning

SCOP / SEER (BS EN14825)

4.3 / 6.5

ErP ENERGY EFFICIENCY CLASS Heating/Cooling

A+ / A++

The Adaptable M Series Range

1.2.6

The Adaptable

M Series
Range

Enhanced Capital Allowance


Mitsubishi Electric has developed a range of highly efficient systems which
successfully qualify for ECA and are registered in the Energy Technology List.
For further information please go to etl.decc.gov.uk/etl

Operational Range
Operation range

MUZ-HJ

MUZ-SF/FH/EF MUFZ-KJ

Cooling

+15C to +46C

-10C to +46C

Heating

-10C to +24C

-15C to +24C

Nominal Conditions: Cooling; indoor 27C DB, 19C WB; outdoor 35C DB, 24C WB.
Nominal Conditions: Heating; indoor 20C DB; outdoor 7C DB, 6C WB.
UK Conditions: Summer; indoor 21C DB, 15C WB; outdoor 27C DB.
UK Conditions: Winter; indoor 21C DB; outdoor 0C DB, -1C WB.

The Adaptable

M Series
Range

Contents

1.2.7

1.121
Air Conditioning

MSZ-HJ Inverter Heat Pump Classic Wall Mounted System

1.2.8

MSZ-SF/GF Inverter Heat Pump Wall Mounted System

1.2.10

MSZ-FH Inverter Heat Pump Wall Mounted System

1.2.12

MSZ-EF Zen Inverter Heat Pump Wall Mounted System

1.2.14

MFZ-KJ Inverter Heat Pump Floor Mounted System

1.2.16

Outdoor Units Product Dimensions

1.2.18

The Adaptable M Series Range

1.2.8

MSZ-HJ Inverter
Heat Pump
Classic Wall
Mounted System

Mitsubishi Electrics range of classic, flat panel wall mounted models make use
of inverter technology, whilst providing extremely good value for money, costing
approximately 20% less than the MSZ-SF equivalent.
These units have extremely quiet sound levels, whilst also delivering
economical air conditioning, with improved SCOP/SEER figures.

Note: Catechin filter is optional.

MSZ-HJ - INDOOR UNITS


CAPACITY (kW)

Heating (nominal)
Cooling (nominal)
Heating (UK)
Cooling (UK)

SHF (nominal & UK)


COP / EER (nominal)
SCOP / SEER (BS EN14825)
ErP ENERGY EFFICIENCY CLASS Heating/Cooling
AIRFLOW (m3/min)
Heating/Cooling - Lo-Mi-Hi-SupHi
PIPE SIZE mm (in)
Gas
Liquid
SOUND PRESSURE LEVEL (dBA) Heating/Cooling - Lo-Mi-Hi-SupHi
SOUND POWER LEVEL (dBA)
DIMENSIONS (mm)
Width x Depth x Height
WEIGHT (kg)
ELECTRICAL SUPPLY
FUSE RATING (BS88) - HRC (A)
INTERCONNECTING CABLE No. CORES

MUZ-HJ - OUTDOOR UNITS


SOUND PRESSURE LEVEL (dBA) Heating/Cooling
SOUND POWER LEVEL (dBA) Cooling
WEIGHT (kg)
DIMENSIONS (mm)
Width x Depth x Height
ELECTRICAL SUPPLY
PHASE
SYSTEM POWER INPUT (kW) Heating/Cooling (nominal)
Heating/Cooling (UK)
STARTING CURRENT (A)
SYSTEM RUNNING CURRENT (A) Heating/Cooling [MAX]
FUSE RATING (BS88) - HRC (A)
MAINS CABLE No. CORES
MAX PIPE LENGTH (m)
MAX HEIGHT DIFFERENCE (m)
CHARGE R410A (kg) - 7m

MSZ-HJ25VA

MSZ-HJ35VA

3.15 (0.9-4.4)
2.5 (0.9-3.0)
2.61 (0.74-3.65)
2.48 (0.89-2.97)
0.89
3.62 / 3.42
3.8 / 5.1
A/A
3.4-5.5-7.5-9.9 / 3.8-5.5-7.3-9.5
9.52 (3/8)
6.35 (1/4)
23-30-37-43 / 22-30-37-43
57
799 x 232 x 290
9
220-240v, 50Hz
10
4

3.6 (0.9-4.8)
3.15 (1.0-3.7)
2.99 (0.74-3.98)
3.12 (0.99-3.67)
0.87
3.62 / 3.03
3.8 / 5.1
A/B
3.4-5.5-7.5-10.3 / 3.8-5.7-7.8-10.9
9.52 (3/8)
6.35 (1/4)
23-30-37-44 / 22-31-37-45
60
799 x 232 x 290
9
220-240v, 50Hz
10
4

MUZ-HJ25VA

MUZ-HJ35VA

50 / 50
63
24
699 x 249 x 530
Fed by Indoor Unit
Single
0.870 / 0.730
0.79 / 0.58
4.2
4.2 / 3.7 [5.8]
10
3
20
12
0.70

50 / 50
64
25
699 x 249 x 530
Fed by Indoor Unit
Single
0.995 / 1.040
0.90 / 0.83
4.9
4.8 / 4.9 [6.5]
10
3
20
12
0.72

Accessories

Product Dimensions

MSZ-HJ25/35VA

No accessories available.

Upper View
799
7

46

785

232
Air in

Front View

Side View
Installation plate

14

100

57

290

Piping

42
103

(5

120

630

49

130
Air out

1.2.9

1.121
Air Conditioning

172

MSZ-HJ Inverter Heat Pump

Drain hose

1.2.10

MSZ-SF/GF
Inverter Heat Pump
Wall Mounted System

The MSZ series has been completely redesigned and features the Nano Platinum filter system.
These models offer industry leading noise levels as low as 21dBA and have a distinctively styled
front panel that not only looks appealing, but also helps to make cleaning of the unit easier.
The MSZ-SF20VA is also compatible with City Multi when used in conjuction with the PAC-LV11M LEV kit please refer to the City Multi section for further information.
Notes: Wide swing & long airflow mode available for MSZ-GF60/71VE. The anti-allergy enzyme filter is optional.

MSZ-SF/GF - INDOOR UNITS


CAPACITY (kW)

Heating (nominal)
Cooling (nominal)
Heating (UK)
Cooling (UK)

SHF (nominal & UK)


COP / EER (nominal)
SCOP / SEER (BS EN14825)
ErP ENERGY EFFICIENCY CLASS Heating/Cooling
AIRFLOW (m3/min)
Heating - Silent-Lo-Mid-Hi-Shi
Cooling - Silent-Lo-Mid-Hi-Shi
PIPE SIZE mm (in)
Gas
Liquid
SOUND PRESSURE LEVEL (dBA) Heating/Cooling - Silent-Lo-Mi-Hi-Shi
SOUND POWER LEVEL (dBA)
DIMENSIONS (mm)
Width x Depth x Height
WEIGHT (kg)
ELECTRICAL SUPPLY
FUSE RATING (BS88) HRC (A)
INTERCONNECTING CABLE No. CORES

MUZ-SF/GF - OUTDOOR UNITS


SOUND PRESSURE LEVEL (dBA) Heating/Cooling
SOUND POWER LEVEL (dBA) Cooling
WEIGHT (kg)
DIMENSIONS (mm)
Width x Depth x Height
ELECTRICAL SUPPLY
PHASE
SYSTEM POWER INPUT (kW)
Heating/Cooling (nominal)
Heating/Cooling (UK)
STARTING CURRENT (A)
SYSTEM RUNNING CURRENT (A) Heating/Cooling [MAX]
FUSE RATING (BS88) HRC (A)
MAINS CABLE No. CORES
MAX PIPE LENGTH (m)
MAX HEIGHT DIFFERENCE (m)
CHARGE R410A (kg)

MSZ-SF20VA only available with MXZ Multi-Split outdoor units

MSZ-SF20VA
3.7-4.4-5-6-6.9
3.5-3.9-4.6-5.5-6.9
9.52 (3/8)
6.35 (1/4)
21-26-30-35 / 21-26-30-35
760 x 168 x 250
7.7
Fed by Outdoor Unit
6
4

MSZ-SF25VE

MSZ-SF35VE

MSZ-SF50VE

MSZ-GF60VE

MSZ-GF71VE

3.2 (1.0-4.1)
4.0 (1.3-4.6)
6.8 (2.0-9.3)
5.8 (1.4-7.3)
8.1 (2.2-9.9)
2.5 (0.9-3.4)
3.5 (1.1-3.8)
6.0 (1.4-7.5)
5.0 (1.4-5.4)
7.1 (2.0-8.7)
2.66 (0.83-3.41)
3.32 (1.1-3.82)
5.65 (1.66-7.73)
4.8 (1.16-6.06)
6.73 (1.83-8.23)
2.5 (0.89-3.37)
3.47 (1.1-3.77)
5.95 (1.38-7.44)
4.96 (1.38-5.35)
7.0 (1.98-8.63)
0.92
0.80
0.79
0.70
0.78
4.10 / 4.17
3.88 / 3.24
3.76 / 3.41
3.41 / 3.01
3.63 / 3.33
4.4 / 7.6
4.4 / 7.2
4.3 / 6.8
4.4 / 7.2
4.2 / 6.8
A+ / A++
A+ / A++
A+ / A++
A+ / A++
A+ / A++
3.5-4.1-6.7-8.2-10.3
3.5-4.1-6.7-8.3-11.0
9.8-11.3-13.4-15.6-18.3
5.6-6.4-8.0-9.8-12.0
10.2-11.5-13.3-15.4-17.8
3.5-4.1-5.5-7.2-9.1
3.5-4.1-5.6-7.2-9.1
9.8-11.3-13.4-15.6-18.3
5.6-6.2-7.0-8.2-9.9
9.7-11.5-13.3-15.4-17.8
9.52 (3/8)
9.52 (3/8)
15.88 (5/8)
12.7 (1/2)
15.88 (5/8)
6.35 (1/4)
6.35 (1/4)
6.35 (1/4)
6.35 (1/4)
9.52 (3/8)
21-24-34-39-45 / 21-24-30-36-42 21-24-34-40-46 / 21-24-30-36-42 30-33-38-43-49 / 30-33-36-40-45 29-37-41-45-49 / 29-37-41-45-49 30-37-41-45-49 / 30-37-41-45-49
57
65
65
57
58
798 x 195 x 299
1100 x 238 x 325
1100 x 238 x 325
798 x 195 x 299
798 x 195 x 299
10
16
16
10
10
Fed by Outdoor Unit
Fed by Outdoor Unit
Fed by Outdoor Unit
Fed by Outdoor Unit
Fed by Outdoor Unit
6
6
6
6
6
4
4
4
4
4

N/A MUlTI-SPlIT ONly

MUZ-SF25VE

MUZ-SF35VE

MUZ-SF50VE

MUZ-GF60VE

MUZ-GF71VE

48 / 47
58
31
800 x 285 x 550
220-240v, 50Hz
Single
0.780 / 0.600
0.71 / 0.49
3.9
3.9 / 3.2 [8.4]
10
3
20
12
0.7 (7m)

50 / 49
62
31
800 x 285 x 550
220-240v, 50Hz
Single
1.030 / 1.080
0.94 / 0.87
4.9
4.7 / 4.9 [8.5]
10
3
20
12
0.8 (7m)

52 / 52
65
55
840 x 330 x 880
220-240v, 50Hz
Single
1.700 / 1.660
1.55 / 1.34
7.6
7.6 / 7.4 [12.3]
16
3
30
15
1.55 (7m)

55 / 55
65
50
840 x 330 x 880
220-240v, 50Hz
Single
1.810 / 1.790
1.65 / 1.45
8.0
8.0 / 7.9 [14.5]
20
3
30
15
1.55 (10m)

55 / 55
65
53
840 x 330 x 880
220-240v, 50Hz
Single
2.230 / 2.130
2.03 / 1.73
9.8
9.8 / 9.3 [16.6]
20
3
30
15
1.90 (10m)

Accessories

Product Dimensions
Upper View

Wall Mounted Units


MAC-2310FT

239

Front View

Side View
168

760

Anti-Allergy filters for MSZ-GF60/71VE (10 pack)

740

5
Installation plate

10

Piping

239

250

MAC-2320FT

MSZ-SF20VA

Outdoor Units

56

41

179

505

MAC-889SG

Air outlet guides for MUZ-SF50VE, MUZ-GF60/71VE

Drain hose

110
Air out

Air outlet guides for MUZ-SF25-35VE

MAC-886SG

56

Enzyme filters for MSZ-SF20-50VE (10 pack)

Product Dimensions

MSZ-SF25/35/50VE

Upper View

Front View

Side View
195

System Control Units

Air in

798

PAR-31MAA

Installation plate

778

10

Wired remote controller for MSZ-SF20-50VE,


MSZ-GF60-71VE
299

Piping

MAC-333IF

577

160

47

Interface for Contact Terminal and PAR-31MAA /


PAC-YT52CRA Wired Remote Controller

( 80 )

58

61

MAC-397IF

100

Interface for group control, run fault and connection


to M-NET System

Drain hose

92
108.5

MAC-557IF
Interface for connection to WiFi MELCloud service

Air out

Product Dimensions
Upper View

MSZ-GF60/71VE

Upper View

Front View

Side View

Front View

Side View
238
Air in

1100
1090

Installation plate

Piping

843

181

65
( 70)

Air out

Air Conditioning
1.2.11 1.121

MSZ-SF/GF Inverter Heat Pump

125
160
184

76

100

12

67

325

Drain hose

1.2.12

MSZ-FH Inverter
Heat Pump

The MSZ-FH series is our most energy efficient M Series wall mounted unit to date.
These high efficiency models feature the Plasma Quad filter system. They also offer industry leading noise levels
and have a distinctively styled front panel that not only looks appealing but also helps to make cleaning of the
unit easier. Also incorporated is a 3D i-see Sensor, providing even temperature distribution and further
reducing energy consumption.

Wall Mounted System

MSZ-FH - INDOOR UNITS


CAPACITY (kW)

Heating (nominal)
Cooling (nominal)
Heating (UK)
Cooling (UK)

SHF (nominal & UK)


COP / EER (nominal)
SCOP / SEER (BS EN14825)
ErP ENERGY EFFICIENCY CLASS Heating/Cooling
AIRFLOW (m3/min)
Heating - SLo-Lo-Mi-Hi-Shi
Cooling - SLo-Lo-Mi-Hi-Shi
PIPE SIZE mm (in)
Gas
Liquid
SOUND PRESSURE LEVEL (dBA) Heating/Cooling - Silent-Lo-Mi-Hi-Shi
SOUND POWER LEVEL (dBA)
DIMENSIONS (mm)
Width x Depth x Height
WEIGHT (kg)
ELECTRICAL SUPPLY
FUSE RATING (BS88) - HRC (A)
INTERCONNECTING CABLE No. CORES

MUZ-FH - OUTDOOR UNITS


SOUND PRESSURE LEVEL (dBA) Heating/Cooling
SOUND POWER LEVEL (dBA) Cooling
WEIGHT (kg)
DIMENSIONS (mm)
Width x Depth x Height
ELECTRICAL SUPPLY
PHASE
SYSTEM POWER INPUT (kW) Heating/Cooling (nominal)
Heating/Cooling (UK)
STARTING CURRENT (A)
SYSTEM RUNNING CURRENT (A) Heating/Cooling [MAX]
FUSE RATING (BS88) - HRC (A)
MAINS CABLE No. CORES
MAX PIPE LENGTH (m)
MAX HEIGHT DIFFERENCE (m)
CHARGE R410A (kg) - 7m

MSZ-FH25VE

MSZ-FH35VE

3.2 (1.8-5.5)
2.5 (1.4-3.5)
2.65 (1.49-4.57)
2.48 (1.38-3.47)
0.95
5.52 / 5.15
5.1 / 9.1
A+++ / A+++

4.0 (1.0-6.3)
3.5 (0.8-4.0)
3.3 (0.8-5.2)
3.47 (0.79-3.97)
0.84
5.00 / 4.27
5.1 / 8.9
A+++ / A+++

4.0-4.7-6.4-9.2-13.2
3.9-4.7-6.3-8.6-11.6
9.52 (3/8)
6.35 (1/4)
20-24-29-36-44 / 20-23-29-36-42
58
925 x 234 x 305
13.5
Fed by Outdoor Unit
6
4

4.0-4.7-6.4-9.2-13.2
3.9-4.7-6.3-8.6-11.6
9.52 (3/8)
6.35 (1/4)
21-24-29-36-44 / 21-24-29-36-42
58
925 x 234 x 305
13.5
Fed by Outdoor Unit
6
4

MUZ-FH25VE

MUZ-FH35VE

49 / 46
60
37
800 x 285 x 550
220-240v, 50Hz
Single
0.580 / 0.485
0.520 / 0.400
2.9
2.9 / 2.6 [9.6]
10
3
20
12
1.15

50 / 49
61
37
800 x 285 x 550
220-240v, 50Hz
Single
0.800 / 0.820
0.760 / 0.690
3.9
3.9 / 3.8 [9.6]
10
3
20
12
1.15

Accessories

Product Dimensions

MSZ-FH25/35VE

Outdoor Units
MAC-889SG
Air outlet guides for MUZ-FH25/35VE

Upper View

System Control Units


PAR-31MAA

925

Wired remote controller for MSZ-FH25/35VE

MAC-333IF

10

905

Interface for group control, run fault and connection


to M-NET System

MAC-397IF
Interface for Contact Terminal and PAR-31MAA /
PAC-YT52CRA Wired Remote Controller

MAC-557IF
234

Interface for connection to WiFi MELCloud service

Air in

Front View

Side View

Installation plate

61

704

51
101

160
Air out

117
132

Air Conditioning
1.2.13 1.121

MSZ-FH Inverter Heat Pump

56

39

100

25

17

Piping

Drain hose

1.2.14

MSZ-EF
Zen Inverter
Heat Pump

The Zen Series is a wall mounted system that blends energy efficiency with a sophisticated, streamlined design.
Combining an impressively low power consumption with a quiet, yet powerful performance, units have a distinctively styled front panel that not
only looks appealing, but also helps to make cleaning of the unit easier. Designed to complement modern interior dcor and suitable for a wide
range of applications, Zen units blend in naturally wherever they are installed and are available in three striking colours; black, silver and white.

Key Features
New stylish design
Energy efficient operation
Compatible with City Multi when used in conjuction with the PAC-LV11M LEV kit, (see the City Multi section)
Recognised by the Noise Abatement Society and awarded the Quiet Mark for industry leading low noise levels

Wall Mounted System

Note: The anti-allergy enzyme filter is optional.

MSZ-EF-B/S/W - INDOOR UNITS


CAPACITY (kW)

Heating (nominal)
Cooling (nominal)
Heating (UK)
Cooling (UK)

SHF (nominal)
COP / EER (nominal)
SCOP / SEER (BS EN14825)
ErP ENERGY EFFICIENCY CLASS Heating/Cooling
AIRFLOW (m3/min)
Heating/Cooling - SLo-Lo-Mi-Hi-Shi
PIPE SIZE mm (in)
Gas
Liquid
SOUND PRESSURE LEVEL (dBA) Heating/Cooling - Silent-Lo-Mi-Hi-Shi
SOUND POWER LEVEL (dBA)
DIMENSIONS (mm)
Width x Depth x Height
WEIGHT (kg)
ELECTRICAL SUPPLY
FUSE RATING (BS88) HRC (A)
INTERCONNECTING CABLE No. CORES

MUZ-EF - OUTDOOR UNITS


SOUND PRESSURE LEVEL (dBA) Heating/Cooling
SOUND POWER LEVEL (dBA) Cooling
WEIGHT (kg)
DIMENSIONS (mm)
Width x Depth x Height
ELECTRICAL SUPPLY
PHASE
SYSTEM POWER
Heating/Cooling (nominal)
INPUT (kW)
Heating/Cooling (UK)
STARTING CURRENT (A)
SYSTEM RUNNING CURRENT (A) Heating/Cooling [MAX]
FUSE RATING (BS88) HRC (A)
MAINS CABLE No. CORES
MAX PIPE LENGTH (m)
MAX HEIGHT DIFFERENCE (m)
CHARGE R410A (kg) - 7m

B = Black

S = Silver W = White

MSZ-EF25VE2-B/S/W

MSZ-EF35VE2-B/S/W

MSZ-EF50VE2-B/S/W

3.2 (1.1-4.2)
2.5 (1.2-3.4)
2.65 (0.91-3.49)
2.48 (1.19-3.37)
0.92
4.57 / 4.59
4.7 / 8.5
A++ / A+++
4.0-4.6-6.2-8.9-11.9 / 4.0-4.6-6.3-8.3-10.5
9.52 (3/8)
6.35 (1/4)
21-24-29-37-45 / 21-23-29-36-42
60
895 x 195 x 299
11.5
Fed by Outdoor Unit
6
4

4.0 (1.8-5.5)
3.5 (1.4-4.0)
3.32 (1.5-4.57)
3.47 (1.38-3.97)
0.80
4.19 / 3.85
4.6 / 8.5
A++ / A+++
4.0-4.6-6.2-8.9-12.7 / 4.0-4.6-6.3-8.3-10.5
9.52 (3/8)
6.35 (1/4)
21-24-30-38-46 / 21-24-29-36-42
60
895 x 195 x 299
11.5
Fed by Outdoor Unit
6
4

5.8 (1.6-7.5)
5.0 (1.4-5.4)
4.82 (1.33-6.23)
4.96 (1.39-5.36)
0.71
3.71 / 3.21
4.5 / 7.2
A+ / A++
6.4-7.3-9.0-11.1-13.2 / 5.8-6.8-7.9-9.3-11.0
12.7 (1/2)
6.35 (1/4)
30-33-37-43-49 / 30-33-36-40-43
60
895 x 195 x 299
11.5
Fed by Outdoor Unit
6
4

MUZ-EF25VE

MUZ-EF35VE

MUZ-EF50VE

48 / 47
58
30
800 x 285 x 550
220-240v, 50Hz
Single
0.700 / 0.545
0.64 / 0.44
3.5
3.5 / 2.9 [7.3]
10
3
20
12
0.8

50 / 49
61
35
800 x 285 x 550
220-240v, 50Hz
Single
0.955 / 0.910
0.87 / 0.73
4.4
4.4 / 4.2 [8.5]
10
3
20
12
1.15

52 / 52
65
54
840 x 330 x 880
220-240v, 50Hz
Single
1.565 / 1.560
1.42 / 1.25
7
7.0 / 6.9 [12.4]
16
3
30
15
1.45

Accessories

Product Dimensions

MSZ-EF25/35/50VE2-B/S/W

Wall Mounted Units


MAC-2320FT
Enzyme filters for MSZ-EF25-50VE (10 pack)

Upper View

Outdoor Units
MAC-889SG

895

Air outlet guides for MUZ-EF25/35VE

875

MAC-886SG

Air outlet guides for MUZ-EF50VE

System Control Units


PAR-31MAA
Wired remote controller for MSZ-EF25-50VE

MAC-333IF
Interface for group control, run fault and connection
to M-NET System

195
Installation

Air in

MAC-397IF

Side View

Front View

Interface for Contact Terminal and PAR-31MAA /


PAC-YT52CRA Wired Remote Controller

plate

MAC-557IF
Interface for connection to WiFi MELCloud service

100

47
(80)

59

678

110

158
A

Air Conditioning
1.2.15 1.121

94

Air out

MSZ-EF Zen Inverter Heat Pump

58

299

Piping

Drain hose

1.2.16

MFZ-KJ Inverter
Heat Pump

The MFZ-KJ series is extremely versatile and is designed for wall attached installation at floor level.
The auto swing vane provides a more natural and comfortable airflow throughout the room and the lightweight,
compact design makes installation easy.

Key Features

Floor Mounted System

New simple, flat design


Energy efficient operation
Optimum air distribution

MFZ-KJ - INDOOR UNITS


CAPACITY (kW)

Heating (nominal)
Cooling (nominal)
Heating (UK)
Cooling (UK)

SHF (nominal & UK)


COP / EER (nominal)
SCOP / SEER (BS EN14825)
ErP ENERGY EFFICIENCY CLASS Heating/Cooling
AIRFLOW (m3/min)
Heating/Cooling - Lo-Mi-Hi-SupHi
PIPE SIZE mm (in)
Gas
Liquid
SOUND PRESSURE LEVEL (dBA) Heating/Cooling - Silent-Lo-Mi-Hi-Shi
SOUND POWER LEVEL (dBA)
DIMENSIONS (mm) Width x Depth x Height
WEIGHT (kg)
ELECTRICAL SUPPLY
FUSE RATING (BS88) HRC (A)
INTERCONNECTING CABLE No. CORES

MUFZ-KJ - OUTDOOR UNITS


SOUND PRESSURE LEVEL (dBA) Heating/Cooling
SOUND POWER LEVEL (dBA) Cooling
WEIGHT (kg)
DIMENSIONS (mm)
Width x Depth x Height
ELECTRICAL SUPPLY
PHASE
SYSTEM POWER INPUT (kW) Heating/Cooling (nominal)
Heating/Cooling (UK)
STARTING CURRENT (A)
SYSTEM RUNNING CURRENT (A) Heating/Cooling [MAX]
FUSE RATING (BS88) HRC (A)
MAINS CABLE No. CORES
MAX PIPE LENGTH (m)
MAX HEIGHT DIFFERENCE (m)
CHARGE R410A (kg) - 7m

MFZ-KJ25VE

MFZ-KJ35VE

MFZ-KJ50VE

3.4 (1.2-4.6)
2.5 (0.5-3.4)
2.85 (0.75-4.25)
2.5 (0.9-3.35)
0.66
4.42 / 4.63
4.5 / 8.5
A+ / A+++
5.0-6.2-7.6-9.4 / 4.8-5.8-7.1-8.9
9.52 (3/8)
6.35 (1/4)
19-25-30-35-41 / 20-25-30-35-39
49
750 x 215 x 600
15
Fed by Outdoor Unit
6
4

4.3 (1.2-5.5)
3.5 (0.5-3.7)
3.3 (0.75-5.15)
3.47 (0.9-3.85)
0.65
3.91 / 3.72
4.4 / 7.8
A+ / A++
5.2-6.2-7.8-9.5 / 5.0-6.1-7.4-9.1
9.52 (3/8)
6.35 (1/4)
19-25-30-35-41 / 20-25-30-35-39
50
750 x 215 x 600
15
Fed by Outdoor Unit
6
4

6.0 (2.2-8.2)
5.0 (1.6-5.7)
5.0 (1.8-6.8)
4.75 (5.58-5.65)
0.63
3.73 / 3.55
4.3 / 6.5
A+ / A++
6.0-7.4-9.4-11.6-14.0 / 5.6-6.7-8.0-9.3-10.6
12.7 (1/2)
6.35 (1/4)
29-35-40-45-50 / 27-31-35-39-44
56
750 x 215 x 600
15
Fed by Outdoor Unit
6
4

MUFZ-KJ25VE

MUFZ-KJ35VE

MUFZ-KJ50VE

51 / 46
59
37
800 x 285 x 550
220-240v, 50Hz
Single
0.77 / 0.54
0.70 / 0.43
3.60
3.6 / 2.7 [9.4]
10
3
20
12
0.8

51 / 47
60
37
800 x 285 x 550
220-240v, 50Hz
Single
1.11 / 0.94
1.01 / 0.74
5.1
5.1 / 4.2 [9.4]
10
3
20
12
1.05

51 / 49
63
55
840 x 330 x 880
220-240v, 50Hz
Single
1.61 / 1.41
1.47 / 1.11
7.1
7.1 / 6.2 [14.0]
20
3
30
15
1.6

Accessories

Product Dimensions

MFZ-KJ25/35/50VE

Floor Mounted Units


MAC-408FT
Enzyme filter for MFZ-KJ25-50VE (10 pack)

Upper View
730

Outdoor Units
MAC-889SG
Air outlet guides for MUFZ-KJ25-35VE

MAC-886SG
Air outlet guides for MUFZ-KJ50VE

System Control Units

Front View

Wired remote controller for MFZ-KJ25-50VE

750
656

47
No obstruction

MAC-333IF

47

Interface for group control, run fault and connection


to M-NET System

MAC-397IF
Interface for Contact Terminal and PAR-31MAA /
PAC-YT52CRA Wired Remote Controller

Side View
28

215
26

PAR-31MAA

70
Air out

MAC-557IF
Interface for connection to WiFi MELCloud service
More than
100mm

148
600

15

15

More than
100mm

47

Air Conditioning
1.2.17 1.121

Drain
656

47

12
60
104
131
153

MFZ-KJ Inverter Heat Pump

30

127

Less than
150mm

205

165

125

60

Air in

303

Sensor hole

1.2.18
Product Dimensions

MUZ-HJ25/35VA

Upper View

Front View

Side View

Air in
Drain hole 33

249

538

19.6

270.3

40

13.5

259

121.4

121

500
55.7

699

Product Dimensions

43

2-10.319.3 Oval hole

157.7

Air out
349.5

102.7

Air in

285

Bolt pitch for


installation
294~267

41.5

17.9

MUZ-SF50VE, MUZ-EF50VE, MUZ-GF60/71VE, MUFZ-KJ50VE

Upper View

Front View

Side View

417.5

Drain hole
40

Air in

42
840

81

50

109

Air out
2-holes 10 21
500

35

164.5

99.5

44

452

175

880

360

330

Outdoor Units

195

Outdoor Units

Product Dimensions

MUZ-SF25/35VE, MUZ-EF25/35VE, MUZ-FH25/35VE, MUFZ-KJ25/35VE

Upper View

400

Drain hole 42

Bolt pitch for


installation
304-325

44
285

Air in

2 holes 10

40

21

17.5

344.5

Air in

Air out

Front View

Side View

22.3

23

150

69

99.5

10

164.5

280

170.5
Service port

302.5

500 Bolt pitch for installation


800

Air Conditioning
1.2.19 1.121

Outdoor Unit Dimensions

43

35

550

Handle

Mr Slim
Packaged Split-System
Air Conditioning

The Adaptable

Mr Slim
Range

Suitable to cool or heat a huge variety of applications such as


offices and retail units, our Mr Slim range is one of Britains best
selling air conditioning split-systems.
Combine the efficiency with the complete versatility that this range has to offer and
the possibilities are virtually infinite.

Power
Inverter

Top of the range Power Inverter technology optimised for high seasonal efficiencies
Available in single and three phase outdoor units
9 models available from 3.5kW-22kW
Available with four way blow cassettes, ducted, floor, wall or ceiling mounted indoor units

Standard
Inverter

High quality cost effective Standard Inverter


Available in single and three phase outdoor units
S Series models from 2.5kW-7kW available with four way blow cassettes,
ducted or ceiling mounted indoor units
Standard Inverter models from 10kW-22kW available with four way
blow cassettes, ducted, floor, wall or ceiling mounted indoor units

Zubadan
Inverter

Optimal performance at low ambient temperature conditions


Quicker defrost and improved start up in heating*
Available in single and three phase outdoor units
3 models available from 7kW-12.5kW
Available with four way blow cassettes, wall or ceiling mounted indoor units

* Will work effectively even when the outdoor ambient air temperature is -25C. At -20C, max heating capacity is achieved in about 20 mins.

1.3.3

1.121
Air Conditioning

1.3.4

The Adaptable

Mr Slim

Twin, Triple and Quad Combinations


The Mr Slim Multi-Split system is an ideal option for open plan spaces in medium sized premises
such as offices or shops, where two, three or four units are required from one outdoor unit.

Range

Twin

Triple

Indoor
Units

Indoor
Units

Outdoor Unit

Quadruple

Indoor
Units

Outdoor Unit

Outdoor Unit

The Adaptable

Mr Slim
Range

Ecodesign and Seasonal Efficiency


With buildings accounting for around half of all UK greenhouse emissions, legislation is demanding
increased energy efficiency. The Ecodesign Directive for Energy Related Products (ErP) is focusing on
this area in a bid to reduce overall energy consumption, and to accelerate market transformation to
more energy efficient products.
An air conditioner will vary performance over changing seasons which means calculating seasonal performance is important to ascertain
the true performance of an air conditioning system. The Ecodesign Directive reflects this by setting minimum efficiency requirements and a
new method of measuring performance introduced across the EU and hence new energy ratings are achievable. The European Standard
BS EN14825:2012 sets the seasonal performance calculation for an air conditioning system under 12kW of which the energy efficiency
class for each product specification is shown. For more information visit the website mitsubishielectric.eu/erp
Product design improvements have enhanced the seasonal efficiency, however this may effect nominal COP/EER.

Example:

SCOP / SEER (BS EN14825)

4.3 / 6.5

ErP ENERGY EFFICIENCY CLASS Heating/Cooling

A+ / A++

Enhanced Capital Allowance


Mitsubishi Electric has developed a range of highly efficient systems which successfully qualify for ECA
and are registered in the Energy Technology List. For further information please go to etl.decc.gov.uk/etl

Operational Range
Operation range

Size

PUHZ-ZRP

PUHZ-P

PUHZ-SHW

SUZ

Cooling

Less than 50
50
60 or more
Less than 50
60 or more

-15C to +46C
-15C to +46C
-15C to +46C
-11C to +21C
-20C to +21C

-15C to +46C
-15C to +46C
-15C to +46C
-15C to +21C
-15C to +21C

-15C to +46C
-15C to +46C
-15C to +46C
-25C to +21C
-25C to +21C

-10C to +46C
-15C to +46C
-15C to +46C
-10C to +24C
-10C to +24C

Heating

Nominal Conditions: Cooling; indoor 27C DB, 19C WB; outdoor 35C DB, 24C WB.
Nominal Conditions: Heating; indoor 20C DB; outdoor 7C DB, 6C WB.
UK Conditions: Summer; indoor 21C DB, 15C WB; outdoor 27C DB.
UK Conditions: Winter; indoor 21C DB; outdoor 0C DB, -1C WB.

1.3.5

1.121
Air Conditioning

1.3.6

The Adaptable

Mr Slim
Range

Indoor Units
Indoor Model
Cassette

4-Way Blow
PLA-(Z)RP

4-Way Blow
Small
600x600
SLZ-KA

Wall

Wall
Mounted
PKA-RP

Ducted

Slim Ceiling
Concealed
SEZ-KD

Ceiling
Concealed
PEAD-RP

Ceiling
Concealed
PEA-RP

Ceiling

Ceiling
Suspended
PCA-RP

Stainless
Ceiling
Suspended
PCA-RP-HAQ

Floor

Floor
Standing
PSA-RP

Air Curtain Air Curtain


HP DX*

* Available as recessed or exposed versions.

Range

2.5kW

3.5kW

5.0kW

6.0kW

7.1kW 10.0kW 12.5kW 14.0kW 19.0kW 22.0kW 38.0kW 44.0kW

The Adaptable

Mr Slim
Range

Contents

1.3.7

1.121
Air Conditioning

SLZ-KA Inverter Heat Pump, 600x600 4-Way Blow Ceiling Cassette System
PLA-ZRP Power Inverter Heat Pump, 4-Way Blow Ceiling Cassette System
PLA-RP Standard Inverter Heat Pump, 4-Way Blow Ceiling Cassette System
PLA-ZRP Zubadan Inverter Heat Pump, 4-Way Blow Ceiling Cassette System
PKA-RP Power Inverter Heat Pump, Wall Mounted System
PKA-RP Standard Inverter Heat Pump, Wall Mounted System
PKA-RP Zubadan Inverter Heat Pump, Wall Mounted System
SEZ-KD Inverter Heat Pump, Ceiling Concealed Ducted System
PEAD-RP Power Inverter Heat Pump, Ceiling Concealed Ducted System
PEAD-RP Standard Inverter Heat Pump, Ceiling Concealed Ducted System
PEAD-RP Zubadan Inverter Heat Pump, Ceiling Concealed Ducted System
PEA-RP Power Inverter Heat Pump, Large Capacity Ceiling Concealed Ducted System
PEA-RP Standard Inverter Heat Pump, Large Capacity Ceiling Concealed Ducted System
PCA-RP Power Inverter Heat Pump, Ceiling Suspended System
PCA-RP Standard Inverter Heat Pump, Ceiling Suspended System
PCA-RP-HAQ Power Inverter Heat Pump, Ceiling Suspended System
PSA-RP Power Inverter Heat Pump, Floor Standing System
PSA-RP Standard Inverter Heat Pump, Floor Standing System
HP DXE Power Inverter Heat Pump, Air Curtain System
PAC-IF Air Handling Unit Controller
Twin, Triple, Quad Combination Tables
Outdoor Units Product Dimensions
Accessories / Optional Extras

1.3.8
1.3.10
1.3.14
1.3.18
1.3.20
1.3.22
1.3.24
1.3.26
1.3.28
1.3.32
1.3.36
1.3.38
1.3.40
1.3.42
1.3.46
1.3.50
1.3.52
1.3.54
1.3.56
1.3.58
1.3.60
1.3.65
1.3.68

1.3.8

SLZ-KA
Inverter
Heat Pump

The SLZ-KA series is perfect for small business applications, as it offers inverter technology
alongside quiet operation. The compact size of this unit is ideal for 600 by 600mm ceilings
with a low height making installation very easy. This unit also comes complete with a long
life filter that will last for approximately 2,500 hours.

600x600 4-Way Blow


Ceiling Cassette System

SLZ-KA-VAQ - INDOOR UNITS


CAPACITY (kW)

SHF (nominal & UK)


COP / EER (nominal)
SCOP / SEER (BS EN14825)
ErP ENERgY EFFICIENCY CLASS
AIRFLOW (m3/min)
PIPE SIZE mm (in)

Heating (nominal)
Cooling (nominal)
Heating (UK)
Cooling (UK)

Heating/Cooling
Lo-Mi-Hi
Gas
Liquid
Lo-Mi-Hi

SOUND PRESSURE LEvEL (dBA)


SOUND POWER LEvEL (dBA)
DIMENSIONS (mm)
Width x Depth x Height
WEIgHT (kg)
Unit / Grille
ELECTRICAL SUPPLY
FUSE RATINg (BS88) - HRC (A)
INTERCONNECTINg CABLE No. Cores
gRILLE REFERENCE
WIRED REMOTE CONTROLLER REFERENCE

SUZ-KA-VA4 - OUTDOOR UNITS


SOUND PRESSURE LEvEL (dBA) Heating/Cooling
SOUND POWER LEvEL (dBA) Cooling
WEIgHT (kg)
DIMENSIONS (mm)
Width x Depth x Height
ELECTRICAL SUPPLY
PHASE
Heating/Cooling (nominal)
SYSTEM POWER
INPUT (kW)
Heating/Cooling (UK)
STARTINg CURRENT (A)
SYSTEM RUNNINg CURRENT (A) Heating/Cooling [MAX]
FUSE RATINg (BS88) - HRC (A)
MAINS CABLE No. Cores
MAX PIPE LENgTH (m)
MAX HEIgHT DIFFERENCE (m)
CHARgE R410A (kg) - 7m

SLZ-KA25VAQ

SLZ-KA35VAQ

SLZ-KA50VAQ

3.2 (1.3-4.5)
2.6 (1.5-3.2)
2.72 (1.11-3.83)
2.39 (1.38-2.94)
0.86
3.76 / 3.71
3.9 / 4.8
A/B
8-9-11
9.52 (3/8)
6.35 (1/4)
29-33-38
57
570 (650) x 570 (650) x 235 (20)
17 / 3
Fed by Outdoor Unit
6
4
SLP-2AAW
PAR-31MAA

4.0 (1.7-5.0)
3.5 (1.4-3.9)
3.4 (1.45-4.25)
3.22 (1.29-3.59)
0.77
3.67 / 3.43
3.9 / 5.1
A/A
8-9-11
9.52 (3/8)
6.35 (1/4)
29-33-38
57
570 (650) x 570 (650) x 235 (20)
17 / 3
Fed by Outdoor Unit
6
4
SLP-2AAW
PAR-31MAA

5.0 (1.7-6.5)
4.6 (2.3-5.2)
4.25 (1.45-5.53)
4.23 (2.12-4.78)
0.68
3.23 / 3.22
3.8 / 5.1
A/A
8-9-11
12.7 (1/2)
6.35 (1/4)
30-34-39
58
570 (650) x 570 (650) x 235 (20)
17 / 3
Fed by Outdoor Unit
6
4
SLP-2AAW
PAR-31MAA

SUZ-KA25VA4

SUZ-KA35VA4

SUZ-KA50VA4

48 / 47
58
30
800 x 285 x 550
220-240v, 50Hz
Single
0.85 / 0.70
0.76 / 0.60
4.0
3.30 / 4.00 [7.4]
10
3
20
12
0.8

50 / 49
62
35
800 x 285 x 550
220-240v, 50Hz
Single
1.09 / 1.02
0.97 / 0.87
5.1
4.80 / 5.10 [8.6]
10
3
20
12
1.15

52 / 52
65
54
840 x 330 x 880
220-240v, 50Hz
Single
1.55 / 1.43
1.38 / 1.22
7.0
6.90 / 7.00 [12.7]
20
3
30
30
1.45

Accessories

Product Dimensions

SLZ-KA25/35/50VAQ

Indoor Units
SLP-2AAW
grille for SLZ-KA25-50vAQ

Upper View

System Control Units


Remote on/off adaptor

Fresh-air
intake

MELCloud WiFi interface

PAR-31MAA

570

650

Remote sensor

530
Suspension bolt
pitch
335

PAC-SE41TS

420
Suspension bolt pitch

Run/fault adapter

576~620 Ceiling hole

PAC-SA88HA

MAC-557IF

650

15~37

PAC-SA89TA

570

57
56

15~37

87

31

Remote controller

199
352
335
576~620 Ceiling hole

15~37

15~37

Side View

Front View
Drain pipe

Refrigerent pipe (gas)

17

202

Wiring entry

230

Ceiling surface

20

Grille
Terminal block

182

Suspension bolt
M10 or 3/8
(purchace locally)

48

235

208

193

Terminal block
(Wired remote controller)

+5
27 0

38~58
Suspension bolt
lower edge

93

121

66

Refrigerent pipe (liquid)

Note: additional accessories are available, please see the Optional Extras page at
the end of this section for the full range.

1.3.9

1.121
Air Conditioning

SLZ-KA Inverter Heat Pump

1.3.10

PLA-ZRP
Power Inverter
Heat Pump
(Single Phase)

Our wide range of Power Inverters offer customers high seasonal efficiency, advanced control
options and quiet operation, whilst providing greater flexibility and ease of installation.

Key Features

Airflow controllable for ceiling heights up to 4.2m, with automatic adjustment of fan speed
Reduced draft air distribution, with independent vane control
Filter lowering operation down to 4m (optional PLP-6BAJ grille required)
Optional i-see sensor' for energy saving and smooth temperature control throughout the room

4-Way Blow Ceiling


Cassette System
PLA-ZRP - INDOOR UNITS

PLA-ZRP35BA

PLA-ZRP50BA

PLA-ZRP60BA

PLA-ZRP71BA

PLA-ZRP100BA

PLA-ZRP125BA

PLA-ZRP140BA

14.0 (5.0-16.0)
16.0 (5.7-18.0)
6.0 (2.5-7.3)
7.0 (2.8-8.2)
8.0 (3.5-10.2)
11.2 (4.5-14.0)
4.1 (1.6-5.2)
12.5 (5.5-14.0)
13.4 (6.2-15.0)
5.0 (2.3-5.6)
6.1 (2.7-6.5)
7.1 (3.3-8.1)
10.0 (4.9-11.4)
3.6 (1.6-4.5)
11.9 (4.25-13.6)
13.6 (4.85-15.3)
5.1 (2.15-6.2)
6.0 (2.38-6.97)
6.8 (3.0-8.65)
9.5 (3.85-11.9)
3.5 (1.35-4.4)
11.5 (5.05-12.9)
12.9 (5.7-14.1)
4.6 (2.1-5.15)
5.6 (2.48-5.98)
6.55 (3.05-7.45)
9.2 (4.5-10.5)
3.3 (1.45-4.15)
0.74
0.72
0.84
0.77
0.85
0.74
0.96
SHF (nominal & UK)
3.81 / 3.23
3.40 / 3.07
3.82 / 3.50
3.43 / 3.43
4.02 / 4.01
4.29 / 3.85
4.77 / 4.56
COP / EER (nominal)
4.1 / 6.0
4.5 / 6.1
4.6 / 6.4
4.2 / 6.1
4.5 / 6.7
4.6 / 6.5
4.6 / 6.8
SCOP / SEER (BS EN14825)
N/A
N/A
A++ / A+
A+ / A++
A+ / A++
A++ / A++
A++ / A++
ErP ENERgY EFFICIENCY CLASS Heating/Cooling
3
22-25-28-31
24-26-29-32
12-14-16-18
12-14-16-18
17-19-21-23
20-23-26-30
11-13-15-16
AIRFLOW (m /min)
Lo-Mi-Mi2-Hi
12.7 (1/2) / 6.35 (1/4) 12.7 (1/2) / 6.35 (1/4) 15.88 (5/8) / 9.52 (3/8) 15.88 (5/8) / 9.52 (3/8) 15.88 (5/8) / 9.52 (3/8) 15.88 (5/8) / 9.52 (3/8) 15.88 (5/8) / 9.52 (3/8)
PIPE SIZE mm (in)
Gas/Liquid
32-34-37-40
34-36-39-41
36-39-42-44
27-28-29-31
28-29-31-32
28-29-31-32
28-30-32-34
SOUND PRESSURE LEvEL (dBA)
Lo-Mi-Mi2-Hi
65
66
70
54
55
55
58
SOUND POWER LEvEL (dBA)
DIMENSIONS (mm)
Width x Depth x Height (Grille) 840 (950) x 840 (950) x 258 (35) 840 (950) x 840 (950) x 258 (35) 840 (950) x 840 (950) x 258 (35) 840 (950) x 840 (950) x 298 (35) 840 (950) x 840 (950) x 298 (35) 840 (950) x 840 (950) x 298 (35) 840 (950) x 840 (950) x 298 (35)
26 / 6
27 / 6
27 / 6
23 / 6
23 / 6
23 / 6
25 / 6
WEIgHT (kg)
Unit / Panel
Fed by Outdoor Unit
Fed by Outdoor Unit
Fed by Outdoor Unit
Fed by Outdoor Unit
Fed by Outdoor Unit
Fed by Outdoor Unit
Fed by Outdoor Unit
ELECTRICAL SUPPLY
6
6
6
6
6
6
6
FUSE RATINg (BS88) - HRC (A)
4
4
4
4
4
4
4
INTERCONNECTINg CABLE No. Cores
PLP-6BA
PLP-6BA
PLP-6BA
PLP-6BA
PLP-6BA
PLP-6BA
PLP-6BA
gRILLE REFERENCE
PAR-31MAA
PAR-31MAA
PAR-31MAA
PAR-31MAA
PAR-31MAA
PAR-31MAA
PAR-31MAA
WIRED REMOTE CONTROLLER REFERENCE
CAPACITY (kW)

Heating (nominal)
Cooling (nominal)
Heating (UK)
Cooling (UK)

PUHZ-ZRP - OUTDOOR UNITS


SOUND PRESSURE LEvEL (dBA) Heating/Cooling
SOUND POWER LEvEL (dBA) Cooling
WEIgHT (kg)
DIMENSIONS (mm) Width x Depth x Height
ELECTRICAL SUPPLY
PHASE
Heating/Cooling (nominal)
SYSTEM POWER
Heating/Cooling (UK)
INPUT (kW)
STARTINg CURRENT (A)
SYSTEM RUNNINg CURRENT (A) Heating/Cooling [MAX]
FUSE RATINg (BS88) - HRC (A)
MAINS CABLE No. Cores
MAX PIPE LENgTH (m)
MAX HEIgHT DIFFERENCE (m)
CHARgE R410A (kg) - 30m

PUHZ-ZRP35VKA

PUHZ-ZRP50VKA

PUHZ-ZRP60VHA

PUHZ-ZRP71VHA

PUHZ-ZRP100VKA PUHZ-ZRP125VKA

PUHZ-ZRP140VKA

51 / 49
48 / 47
48 / 47
46 / 44
46 / 44
52 / 50
52 / 50
69
67
67
65
65
70
70
116
67
67
46
43
116
119
809 x 300 + 23 x 630 809 x 300 + 23 x 630 950 x 330 + 30 x 943 950 x 330 + 30 x 943 1050 x 330 + 30 x 1338 1050 x 330 + 30 x 1338 1050 x 330 + 30 x 1338
220-240v, 50Hz
220-240v, 50Hz
220-240v, 50Hz
220-240v, 50Hz
220-240v, 50Hz
220-240v, 50Hz
220-240v, 50Hz
Single
Single
Single
Single
Single
Single
Single
1.99 / 1.77
2.04 / 1.90
1.57 / 1.43
0.86 / 0.79
2.61 / 2.60
3.67 / 3.87
4.70 / 4.37
1.77 / 1.50
1.71 / 1.51
1.40 / 1.22
0.77 / 0.67
2.32 / 2.21
3.27 / 3.29
4.18 / 3.71
6.0
5.0
5.0
4.0
12.0
12.0
12.0
8.80 / 7.81 [19.5]
9.14 / 7.98 [19.3]
7.13 / 6.49 [13.3]
4.17 / 3.82 [13.3]
11.90 / 11.87 [27.2]
16.37 / 17.30 [27.3]
21.14 / 19.75 [29.1]
25
25
16
16
32
32
40
3
3
3
3
3
3
3
50
50
50
50
75
75
75
30
30
30
30
30
30
30
3.5
3.5
2.4
2.2
5.0
5.0
5.0

Accessories

Product Dimensions

PLA-ZRP35/50/60/71/100/125/140BA

Indoor Units
PLP-6BA
grille for PLA-ZRP35-140BA

PAC-SH53TM

Upper View

Multi function casement PLA-ZRP35-140BA for


fresh air 100mm knockout or to hold the high
efficiency filter option

950

Ceiling hole

20~45

160

Suspension bolt pitch

20~45

Fresh air
intake hole

840

950

Branch duct hole

Outdoor Units

Indoor power supply


terminal block(optional part)

PAC-SJ07SG

860~910

Corner panel i-see sensor PLA-ZRP35-140BA

Remote controller
terminal block
Indoor unit/Outdoor
unit connecting
terminal block

620

PAC-SA1ME

Suspension bolt pitch

grille with filter lowering function PLA-ZRP35-140BA

605

160

PLP-6BAJ

(7.5)

grille and infra-red controller PLA-ZRP35-140BA

Ceiling hole

PLP-6BALM

20~45

860~910
810

Models

(7.5)

24

160

90

150

Air outlet guide for PUHZ-ZRP35-50vKA

PAC-SG59SG

187.5

20~45

Air outlet guide for PUHZ-ZRP60-71vHA

PAC-SH96SG

Branch duct hole

160
840

PLA-ZRP35BA
PLA-ZRP50BA
PLA-ZRP60BA
PLA-ZRP71BA
PLA-ZRP100BA
PLA-ZRP125BA
PLA-ZRP140BA

C
80

241 258

74

400

77

440

87
281 298 85

Air outlet guide for PUHZ-ZRP100-140vKA

Side View

PAC-SA89TA

MELCloud WiFi interface

PAC-SJ19MA
A/M-NET adaptor for PUHZ-ZRP35-50vKA

377

Drain pipe

90

100

100

90

Cut out hole


100

Control wire entry

155

Keep approximately
10 to 15mm space
between unit ceiling
and ceiling slab.

175
Burring hole pitch

350

167

190

35

Ceiling
Grille

Power supply wire,


Indoor unit/Outdoor unit
connecting wire entry

17 +50

Suspension bolt
lower edge

156

70

Refrigerant pipe (gas)

105

Remote sensor

MAC-557IF

284

Refrigerant pipe (liquid)

50~70

PAC-SE41TS

60

140

Run/fault adapter

Suspension bolt
M10 or W3/8

170

Remote on/off adaptor

PAC-SA88HA

Front View

130

System Control Units

14- 2.8
150

Burring hole

Cut out hole

PAC-SF83MA
A/M-NET adaptor for PUHZ-ZRP60-140vHA (vKA)

PAR-31MAA
Remote controller
Note: additional accessories are available, please see the Optional Extras page at
the end of this section for the full range.

Air Conditioning
1.3.11 1.121

PLA-ZRP Power Inverter Heat Pump (Single Phase)

1.3.12

PLA-ZRP
Power Inverter
Heat Pump
(Three Phase)

Our wide range of Power Inverters offer customers high seasonal efficiency, advanced control
options and quiet operation, whilst providing greater flexibility and ease of installation.

Key Features

Airflow controllable for ceiling heights up to 4.2m, with automatic adjustment of fan speed
Reduced draft air distribution, with independent vane control
Filter lowering operation down to 4m (optional PLP-6BAJ grille required)
Optional i-see sensor' for energy saving and smooth temperature control throughout the room

4-Way Blow Ceiling


Cassette System
PLA-ZRP - INDOOR UNITS
CAPACITY (kW)

Heating (nominal)
Cooling (nominal)
Heating (UK)
Cooling (UK)

SHF (nominal & UK)


COP / EER (nominal)
SCOP / SEER (BS EN14825)
ErP ENERgY EFFICIENCY CLASS Heating/Cooling
Lo-Mi-Mi2-Hi
AIRFLOW (m3/min)
PIPE SIZE mm (in)
Gas/Liquid
SOUND PRESSURE LEvEL (dBA)
Lo-Mi-Mi2-Hi
SOUND POWER LEvEL (dBA)
DIMENSIONS (mm)
Width x Depth x Height (Grille)
WEIgHT (kg)
Unit / Panel
ELECTRICAL SUPPLY
FUSE RATINg (BS88) - HRC (A)
INTERCONNECTINg CABLE No. Cores
gRILLE REFERENCE
WIRED REMOTE CONTROLLER REFERENCE

PUHZ-ZRP - OUTDOOR UNITS


SOUND PRESSURE LEvEL (dBA) Heating/Cooling
SOUND POWER LEvEL (dBA) Cooling
WEIgHT (kg)
DIMENSIONS (mm) Width x Depth x Height
ELECTRICAL SUPPLY
PHASE
Heating/Cooling (nominal)
SYSTEM POWER
INPUT (kW)
Heating/Cooling (UK)
STARTINg CURRENT (A)
SYSTEM RUNNINg CURRENT (A) Heating/Cooling [MAX]
FUSE RATINg (BS88) - HRC (A)
MAINS CABLE No. Cores
MAX PIPE LENgTH (m)
MAX HEIgHT DIFFERENCE (m)
CHARgE R410A (kg) - 30m

3 Three Phase

PLA-ZRP100BA

PLA-ZRP125BA

PLA-ZRP140BA

11.2 (4.5-14.0)
10.0 (4.9-11.4)
9.5 (3.85-11.9)
9.2 (4.5-10.5)
0.74
4.29 / 3.85
4.6 / 6.4
A++ / A++
20-23-26-30
15.88 (5/8) / 9.52 (3/8)
32-34-37-40
65
840 (950) x 840 (950) x 298 (35)
26 / 6
Fed by Outdoor Unit
6
4
PLP-6BA
PAR-31MAA

14.0 (5.0-16.0)
12.5 (5.5-14.0)
11.9 (4.25-13.6)
11.5 (5.05-12.9)
0.74
3.81 / 3.23
4.1 / 5.9
N/A
22-25-28-31
15.88 (5/8) / 9.52 (3/8)
34-36-39-41
66
840 (950) x 840 (950) x 298 (35)
27 / 6
Fed by Outdoor Unit
6
4
PLP-6BA
PAR-31MAA

16.0 (5.7-18.0)
13.4 (6.2-15.0)
13.6 (4.85-15.3)
12.9 (5.7-14.1)
0.72
3.40 / 3.07
4.5 / 6.0
N/A
24-26-29-32
15.88 (5/8) / 9.52 (3/8)
36-39-42-44
70
840 (950) x 840 (950) x 298 (35)
27 / 6
Fed by Outdoor Unit
6
4
PLP-6BA
PAR-31MAA

PUHZ-ZRP100YKA
Three Phase

51 / 49
69
124
1050 x 330 + 30 x 1338
380-415v,50Hz
Three
2.61 / 2.60
2.32 / 2.21
4.0
4.82 / 4.84 [8.7]
16
5
75
30
5.0

PUHZ-ZRP125YKA
Three Phase

52 / 50
70
126
1050 x 330 + 30 x 1338
380-415v,50Hz
Three
3.67 / 3.87
3.27 / 3.29
4.0
6.25 / 6.64 [10.3]
16
5
75
30
5.0

PUHZ-ZRP140YKA
Three Phase

52 / 50
70
132
1050 x 330 + 30 x 1338
380-415v,50Hz
Three
4.70 / 4.37
4.18 / 3.71
4.0
8.09 / 7.68 [12.1]
16
5
75
30
5.0

Accessories

Product Dimensions

PLA-ZRP100/125/140BA

Indoor Units
PLP-6BA
grille for PLA-ZRP100-140BA

Upper View

PAC-SH53TM
Multi function casement PLA-ZRP100-140BA
for fresh air 100mm knockout or to hold the high
efficiency filter option

950

Ceiling hole

20~45

160

Suspension bolt pitch

20~45

Fresh air
intake hole

PLP-6BALM

20~45

860~910
810

Indoor power supply


terminal block(optional part)

Outdoor Units

860~910

Ceiling hole

840

Branch duct hole


950

Corner panel i-see sensor PLA-ZRP100-140BA

620

PAC-SA1ME

Remote controller
terminal block
Indoor unit/Outdoor
unit connecting
terminal block

Suspension bolt pitch

grille with filter lowering function PLA-ZRP100-140BA

605

160

PLP-6BAJ

(7.5)

grille and infra-red controller PLA-ZRP100-140BA

Branch duct hole

(7.5)

160

24
187.5

Models
20~45

System Control Units

90

Air outlet guide for PUHZ-ZRP100-140YKA

150

PAC-SH96SG

160
840

PAC-SA89TA

PLA-ZRP100BA
PLA-ZRP125BA
PLA-ZRP140BA

281 298 85

77

440

Remote on/off adaptor

PAC-SA88HA

60

284

377

Drain pipe

PAR-31MAA
Remote controller

100

90

Cut out hole


100

Control wire entry

Ceiling
Grille

155

Keep approximately
10 to 15mm space
between unit ceiling
and ceiling slab.

175
Burring hole pitch

350

167

Power supply wire,


Indoor unit/Outdoor unit
connecting wire entry

156

105

140

170

Suspension bolt
lower edge

35

70

Refrigerant pipe (gas)

50~70

A/M-NET adaptor for PUHZ-ZRP100-140YKA

100

Refrigerant pipe (liquid)

MELCloud WiFi interface

PAC-SF83MA

90

MAC-557IF

Suspension bolt
M10 or W3/8

190

Remote sensor

17 +50

PAC-SE41TS

Front View

130

Side View

Run/fault adapter

14- 2.8
150

Burring hole

Cut out hole

Note: additional accessories are available, please see the Optional Extras page at
the end of this section for the full range.

Air Conditioning
1.3.13 1.121

PLA-ZRP Power Inverter Heat Pump (Three Phase)

1.3.14

PLA-RP
Standard Inverter
Heat Pump
(Single Phase)

Our Standard Inverter range offers customers all the features and benefits of inverter technology
whilst being cost effective.

Key Features

Airflow controllable for ceiling heights up to 4.2m, with automatic adjustment of fan speed
Reduced draft air distribution, with independent vane control
Filter lowering operation down to 4m (optional PLP-6BAJ grille required)
Optional i-see sensor for energy saving and smooth temperature control throughout the room
3-phase Standard Inverters available

4-Way Blow Ceiling


Cassette System
PLA-RP - INDOOR UNITS

PLA-RP35BA

PLA-RP50BA

PLA-RP60BA

PLA-RP71BA

PLA-RP100BA

PLA-RP125BA

PLA-RP140BA2

14.0 (5.0-16.0)
16.0 (5.0-18.0)
4.1 (1.7-5.0)
6.9 (2.5-8.0)
8.0 (2.6-10.2)
11.2 (4.5-12.5)
6.0 (1.7-7.2)
12.3 (5.5-14.0)
13.6 (5.5-15.0)
3.6 (1.4-3.9)
6.1 (2.3-6.3)
7.1 (2.8-8.1)
9.4 (4.9-11.2)
5.5 (2.3-5.6)
11.9 (4.25-13.6)
13.6 (4.25-15.3)
3.49 (1.45-4.25)
5.87 (2.13-6.80)
6.80 (2.21-8.67)
9.5 (3.85-10.65)
5.10 (1.45-6.12)
11.3 (5.05-12.9)
12.5 (5.05-13.8)
3.31 (1.29-3.59)
5.61 (2.12-5.80)
6.53 (2.58-7.45)
8.65 (4.5-10.3)
5.06 (2.12-5.15)
0.71
0.71
0.84
0.76
0.73
0.74
0.81
SHF (nominal & UK)
3.41 / 3.01
3.21 / 2.61
3.94 / 3.30
3.50 / 3.32
3.56 / 3.38
3.41 / 3.01
3.43 / 3.31
COP / EER (nominal)
3.7 / 3.6
3.4 / 3.1
4.2 / 6.0
4.1 / 6.0
4.3 / 5.8
3.8 / 5.2
4.0 / 6.0
SCOP / SEER (BS EN14825)
N/A
N/A
A+ / A+
A+/ A+
A+ / A+
A/A
A+ / A+
ErP ENERgY EFFICIENCY CLASS Heating/Cooling
22-25-28-31
24-26-29-32
11-12-13-15
12-14-16-18
14-16-18-21
20-23-26-30
12-14-16-18
Lo-Mi1-Mi2-Hi
AIRFLOW (m3/min)
9.52 (3/8) / 6.35 (1/4) 12.7 (1/2) / 6.35 (1/4) 15.88 (5/8) / 6.35 (1/4) 15.88 (5/8) / 9.52 (3/8) 15.88 (5/8) / 9.52 (3/8) 15.88 (5/8) / 9.52 (3/8) 15.88 (5/8) / 9.52 (3/8)
PIPE SIZE mm (in)
Gas/Liquid
32-34-37-40
34-36-39-41
36-39-42-44
27-28-29-31
28-29-31-32
28-29-31-32
28-30-32-34
SOUND PRESSURE LEvEL (dBA)
Lo-Mi1-Mi2-Hi
62
63
70
54
55
55
56
SOUND POWER LEvEL (dBA)
DIMENSIONS (mm)
Width x Depth x Height (Grille) 840 (950) x 840 (950) x 258 (35) 840 (950) x 840 (950) x 258 (35) 840 (950) x 840 (950) x 258 (35) 840 (950) x 840 (950) x 258 (35) 840 (950) x 840 (950) x 298 (35) 840 (950) x 840 (950) x 298 (35) 840 (950) x 840 (950) x 298 (35)
25 / 6
25 / 6
27 / 6
22 / 6
22 / 6
23 / 6
23 / 6
WEIgHT (kg)
Unit / Panel
Fed by Outdoor Unit
Fed by Outdoor Unit
Fed by Outdoor Unit
Fed by Outdoor Unit
Fed by Outdoor Unit
Fed by Outdoor Unit
Fed by Outdoor Unit
ELECTRICAL SUPPLY
6
6
6
6
6
6
6
FUSE RATINg (BS88) - HRC (A)
4
4
4
4
4
4
4
INTERCONNECTINg CABLE No. Cores
PLP-6BA
PLP-6BA
PLP-6BA
PLP-6BA
PLP-6BA
PLP-6BA
PLP-6BA
gRILLE REFERENCE
PAR-31MAA
PAR-31MAA
PAR-31MAA
PAR-31MAA
PAR-31MAA
PAR-31MAA
PAR-31MAA
WIRED REMOTE CONTROLLER REFERENCE
CAPACITY (kW)

Heating (nominal)
Cooling (nominal)
Heating (UK)
Cooling (UK)

SUZ-KA / PUHZ-P- OUTDOOR UNITS

SUZ-KA35VA4

SUZ-KA50VA4

SUZ-KA60VA4

SUZ-KA71VA4

SOUND PRESSURE LEvEL (dBA) Heating/Cooling


SOUND POWER LEvEL (dBA) Cooling
WEIgHT (kg)
DIMENSIONS (mm) Width x Depth x Height
ELECTRICAL SUPPLY
PHASE
Heating/Cooling (nominal)
SYSTEM POWER
Heating/Cooling (UK)
INPUT (kW)
STARTINg CURRENT (A)
SYSTEM RUNNINg CURRENT (A) Heating/Cooling [MAX]
FUSE RATINg (BS88) - HRC (A)
MAINS CABLE No. Cores
MAX PIPE LENgTH (m)
MAX HEIgHT DIFFERENCE (m)
CHARgE R410A (kg)

50 / 49
62
35
800 x 285 x 550
220-240v, 50Hz
Single
1.04 / 1.09
0.93 / 0.93
5.0
5.00 / 5.00 [8.4]
10
3
20
12
1.15

52 / 52
65
54
840 x 330 x 880
220-240v, 50Hz
Single
1.75 / 1.66
1.56 / 1.41
7.7
7.70 / 7.40 [12.4]
20
3
30
30
1.45

55 / 55
65
50
840 x 330 x 880
220-240v, 50Hz
Single
1.97 / 1.84
1.75 / 1.56
8.7
7.90 / 8.70 [14.4]
20
3
30
30
1.55

55 / 55
69
53
840 x 330 x 880
220-240v, 50Hz
Single
2.25 / 2.10
2.00 / 1.79
9.7
9.20 / 9.70 [16.6]
20
3
30
30
1.9

Notes: All units charged to 7m (35-71), 30m (100-140) pipe length. No duty/standby operation on SUZ-KA35/50/60/71VA4.

PUHZ-P100VHA4

PUHZ-P125VHA3

PUHZ-P140VHA3

54 / 50
55 / 51
56 / 52
70
71
73
75
99
99
950 x 330 + 30 x 943 950 x 330 + 30 x 1350 950 x 330 + 30 x 1350
220-240v, 50Hz
220-240v, 50Hz
220-240v, 50Hz
Single
Single
Single
3.280 / 3.120
4.110 / 4.090
4.980 / 5.210
2.92 / 2.65
3.66 / 3.48
4.43 / 4.43
12.0
15.0
15.0
15.57 / 14.92 [28.9]
17.68 / 18.37 [29.0]
22.31 / 23.55 [30.5]
32
32
40
3
3
3
50
50
50
30
30
30
3.0
4.5
4.5

Accessories

Product Dimensions

PLA-RP35/50/60/71/100/125/140BA(2)

Indoor Units
PLP-6BA
grille for PLA-RP35-140BA(2)

Upper View

PAC-SH53TM
Multi function casement PLA-RP35-140BA(2)
for fresh air 100mm knockout or to hold the high
efficiency filter option

950

Ceiling hole

20~45

20~45

860~910
810
160

Suspension bolt pitch

20~45

PLP-6BALM

Fresh air
intake hole

Indoor power supply


terminal block(optional part)

Outdoor Units

860~910

840

950

Branch duct hole

Ceiling hole

Corner panel i-see sensor PLA-RP35-140BA(2)

Remote controller
terminal block
Indoor unit/Outdoor
unit connecting
terminal block

620

PAC-SA1ME

Suspension bolt pitch

grille with filter lowering function PLA-RP35-140BA(2)

605

160

PLP-6BAJ

(7.5)

grille and infra-red controller PLA-RP35-140BA(2)

PAC-SG59SG

80
74

241 258

400

87
(7.5)

24

160

90

C AD

PLA-RP35/50BA

PLA-RP60BA
150

Air outlet guide for PUHZ-P100-140

Models
Branch duct hole

System Control Units

20~45

PLA-RP71BA
187.5

160
840

PLA-RP100,125BA
PLA-RP140BA2

281 298

85 77

440

PAC-SA89TA
Remote on/off adaptor

PAC-SA88HA

Side View

Front View

Run/fault adapter
Suspension bolt
M10 or W3/8

Remote sensor

Refrigerant pipe (liquid)

MAC-557IF

Refrigerant pipe (gas)

PAR-31MAA
Remote controller

377

Drain pipe

90

100

100

90

Cut out hole

Control wire entry

155

Keep approximately
10 to 15mm space
between unit ceiling
and ceiling slab.

175
Burring hole pitch

350

167

B
35

190

Ceiling
Grille

17 +50

Power supply wire,


Indoor unit/Outdoor unit
connecting wire entry

156

105

70

100

284

140

Suspension bolt
lower edge

50~70

A/M-NET adaptor for PUHZ-P100-140vHA4(3)

170

MELCloud WiFi interface

PAC-SF83MA

60

130

PAC-SE41TS

14- 2.8
150

Burring hole

Cut out hole

Note: additional accessories are available, please see the Optional Extras page at
the end of this section for the full range.

Air Conditioning
1.3.15 1.121

PLA-RP Standard Inverter Heat Pump (Single Phase)

1.3.16

PLA-RP
Standard Inverter
Heat Pump
(Three Phase)

Our Standard Inverter range offers customers all the features and benefits of inverter technology
whilst being cost effective.

Key Features

Airflow controllable for ceiling heights up to 4.2m, with automatic adjustment of fan speed
Reduced draft air distribution, with independent vane control
Filter lowering operation down to 4m (optional PLP-6BAJ grille required)
Optional i-see sensor for energy saving and smooth temperature control throughout the room

4-Way Blow Ceiling


Cassette System
PLA-RP - INDOOR UNITS
CAPACITY (kW)

Heating (nominal)
Cooling (nominal)
Heating (UK)
Cooling (UK)

SHF (nominal & UK)


COP / EER (nominal)
SCOP / SEER (BS EN14825)
ErP ENERgY EFFICIENCY CLASS Heating/Cooling
AIRFLOW (m3/min)
Lo-Mi1-Mi2-Hi
PIPE SIZE mm (in)
Gas/Liquid
SOUND PRESSURE LEvEL (dBA)
Lo-Mi1-Mi2-Hi
SOUND POWER LEvEL (dBA)
DIMENSIONS (mm)
Width x Depth x Height (Grille)
WEIgHT (kg)
Unit / Panel
ELECTRICAL SUPPLY
FUSE RATINg (BS88) - HRC (A)
INTERCONNECTINg CABLE No. Cores
gRILLE REFERENCE
WIRED REMOTE CONTROLLER REFERENCE

PUHZ-P - OUTDOOR UNITS


SOUND PRESSURE LEvEL (dBA) Heating/Cooling
SOUND POWER LEvEL (dBA) Cooling
WEIgHT (kg)
DIMENSIONS (mm) Width x Depth x Height
ELECTRICAL SUPPLY
PHASE
Heating/Cooling (nominal)
SYSTEM POWER
INPUT (kW)
Heating/Cooling (UK)
STARTINg CURRENT (A)
SYSTEM RUNNINg CURRENT (A) Heating/Cooling [MAX]
FUSE RATINg (BS88) - HRC (A)
MAINS CABLE No. Cores
MAX PIPE LENgTH (m)
MAX HEIgHT DIFFERENCE (m)
CHARgE R410A (kg)

3 Three Phase

PLA-RP100BA

PLA-RP125BA

PLA-RP140BA2

11.2 (4.5-12.5)
9.4 (4.9-11.2)
9.5 (3.85-10.65)
8.65 (4.5-10.3)
0.74
3.41 / 3.01
3.8 / 5.2
A/A
20-23-26-30
15.88 (5/8) / 9.52 (3/8)
32-34-37-40
62
840 (950) x 840 (950) x 298 (35)
25 / 6
Fed by Outdoor Unit
6
4
PLP-6BA
PAR-31MAA

14.0 (5.0-16.0)
12.3 (5.5-14.0)
11.9 (4.25-13.6)
11.3 (5.05-12.9)
0.71
3.41 / 3.01
3.7 / 3.6
N/A
22-25-28-31
15.88 (5/8) / 9.52 (3/8)
34-36-39-41
63
840 (950) x 840 (950) x 298 (35)
25 / 6
Fed by Outdoor Unit
6
4
PLP-6BA
PAR-31MAA

16.0 (5.0-18.0)
13.6 (5.5-15.0)
13.6 (4.25-15.3)
12.5 (5.05-13.8)
0.71
3.21 / 2.61
3.4 / 3.1
N/A
24-26-29-32
15.88 (5/8) / 9.52 (3/8)
36-39-42-44
70
840 (950) x 840 (950) x 298 (35)
27 / 6
Fed by Outdoor Unit
6
4
PLP-6BA
PAR-31MAA

PUHZ-P100YHA2
Three Phase

54 / 50
70
77
950 x 330 + 30 x 943
380-415v, 50Hz
Three
3.280 / 3.120
2.92 / 2.65
4.0
6.13 / 5.94 [13.9]
16
5
50
30
3.0

Notes: All units charged to 7m (35-71), 30m (100-140) pipe length.

PUHZ-P125YHA
Three Phase

55 / 51
71
101
950 x 330 + 30 x 1350
380-415v, 50Hz
Three
4.110 / 4.090
3.66 / 3.48
5.0
7.03 / 7.18 [14.0]
16
5
50
30
4.5

PUHZ-P140YHA
Three Phase

56 / 52
73
101
950 x 330 + 30 x 1350
380-415v, 50Hz
Three
4.980 / 5.210
4.43 / 4.43
5.0
8.58 / 8.99 [14.0]
16
5
50
30
4.5

Accessories

Product Dimensions

PLA-RP100/125/140BA(2)

Indoor Units
PLP-6BA
grille for PLA-RP100-140BA(2)

Upper View

PAC-SH53TM
Multi function casement PLA-RP100-140BA(2)
for fresh air 100mm knockout or to hold the high
efficiency filter option

950

Ceiling hole

20~45

20~45

860~910
810

20~45

160

Suspension bolt pitch

Indoor power supply


terminal block(optional part)

Outdoor Units

860~910

840

950

Branch duct hole

620

Corner panel i-see sensor PLA-RP100-140BA(2)

Remote controller
terminal block
Indoor unit/Outdoor
unit connecting
terminal block

Suspension bolt pitch

grille with filter lowering function PLA-RP100-140BA(2)

PAC-SA1ME

605

160

PLP-6BAJ

(7.5)

grille and infra-red controller PLA-RP100-140BA(2)

Ceiling hole

PLP-6BALM

Fresh air
intake hole

Branch duct hole

(7.5)

160

24
187.5

Models
20~45

System Control Units

90

Air outlet guide for PUHZ-P100-140YHA(2)

150

PAC-SG59SG

160
840

PLA-RP100/125BA
281 298 85
PLA-RP140BA(2)

77

440

PAC-SA89TA
Remote on/off adaptor

Side View

Run/fault adapter

PAR-31MAA
Remote controller

90

100

100

90

Cut out hole


100

Control wire entry

Ceiling
Grille

155

Keep approximately
10 to 15mm space
between unit ceiling
and ceiling slab.

175
Burring hole pitch

350

167

190

Power supply wire,


Indoor unit/Outdoor unit
connecting wire entry

35

Suspension bolt
lower edge

156

70

Refrigerant pipe (gas)

A/M-NET adaptor for PUHZ-P100-140YHA(2)

Drain pipe

17 +50

PAC-SF83MA

377

105

MELCloud WiFi interface

284

Refrigerant pipe (liquid)

50~70

MAC-557IF

60

140

Remote sensor

Suspension bolt
M10 or W3/8

170

PAC-SE41TS

Front View

130

PAC-SA88HA

14- 2.8
150

Burring hole

Cut out hole

Note: additional accessories are available, please see the Optional Extras page at
the end of this section for the full range.

Air Conditioning
1.3.17 1.121

PLA-RP Standard Inverter Heat Pump (Three Phase)

1.3.18

PLA-ZRP
Zubadan Inverter
Heat Pump
4-Way Blow Ceiling
Cassette System

The Mr Slim Zubadan Inverter heat pumps achieve an excellent heating performance
even when the outdoor air temperature is as low as -25C.

Key Features
Stable heating performance - Full heating capacity at -15C, a 30% capacity improvement over the next size up Power Inverter
Expanded heating operation - Will work effectively even when the outdoor ambient air temperature is -25C
Stable operation - Utilising a Flash Injection Circuit, the Zubadan models have reduced defrost times
and can provide continuous heating for up to 150 mins
Quick start-up - At -20C, max heating capacity is achieved in about 20 mins, improving comfort levels

PLA-ZRP - INDOOR UNITS


CAPACITY (kW)

Heating (nominal)
Cooling (nominal)
Heating (UK)
Cooling (UK)

SHF (nominal & UK)


COP / EER (nominal)
SCOP / SEER (BS EN14825)
ErP ENERgY EFFICIENCY CLASS Heating/Cooling
Lo-Mi1-Mi2-Hi
AIRFLOW (m3/min)
PIPE SIZE mm (in)
Gas/Liquid
SOUND PRESSURE LEvEL (dBA)
Lo-Mi1-Mi2-Hi
SOUND POWER LEvEL (dBA)
DIMENSIONS (mm)
Width x Depth x Height (Grille)
WEIgHT (kg)
Unit / Panel
ELECTRICAL SUPPLY
FUSE RATINg (BS88) - HRC (A)
INTERCONNECTINg CABLE No. Cores
gRILLE REFERENCE
WIRED REMOTE CONTROLLER REFERENCE

PUHZ-SHW - OUTDOOR UNITS


SOUND PRESSURE LEvEL (dBA) Heating/Cooling
SOUND POWER LEvEL (dBA) Cooling
WEIgHT (kg)
DIMENSIONS (mm) Width x Depth x Height
ELECTRICAL SUPPLY
PHASE
Heating/Cooling (nominal)
SYSTEM POWER
INPUT (kW)
Heating/Cooling (UK)
STARTINg CURRENT (A)
SYSTEM RUNNINg CURRENT (A) Heating/Cooling [MAX]
FUSE RATINg (BS88) - HRC (A)
MAINS CABLE No. Cores
MAX PIPE LENgTH (m)
MAX HEIgHT DIFFERENCE (m)
CHARgE R410A (kg) - 30m

3 Three Phase

PLA-ZRP71BA

PLA-ZRP100BA

PLA-ZRP100BA

PLA-ZRP125BA

8.0 (4.5-10.2)
7.1 (4.9-8.1)
6.8 (3.9-8.65)
6.55 (4.5-7.45)
0.85
3.91 / 3.81
3.7 / 5.1
A/A
17-19-21-23
15.88 (5/8) / 9.52 (3/8)
28-30-34-36
58
840 (950) x 840 (950) x 258 (35)
25 / 6
Fed by Outdoor Unit
6
4
PLP-6BA
PAR-31MAA

11.2 (4.5-14.0)
10.0 (4.9-11.4)
9.5 (3.85-11.9)
9.2 (4.5-10.5)
0.74
4.20 / 3.59
4.0 / 5.5
A+ / A
20-23-26-30
15.88 (5/8) / 9.52 (3/8)
32-34-37-40
65
840 (950) x 840 (950) x 298 (35)
26 / 6
Fed by Outdoor Unit
6
4
PLP-6BA
PAR-31MAA

11.2 (4.5-14.0)
10.0 (4.9-11.4)
9.5 (3.85-11.9)
9.2 (4.5-10.5)
0.74
4.20 / 3.59
4.0 / 5.5
A+ / A
20-23-26-30
15.88 (5/8) / 9.52 (3/8)
32-34-37-40
65
840 (950) x 840 (950) x 298 (35)
26 / 6
Fed by Outdoor Unit
6
4
PLP-6BA
PAR-31MAA

14.0 (5.0-16.0)
12.5 (5.5-14.0)
11.9 (4.25-13.6)
11.5 (5.05-12.9)
0.74
3.61 / 2.81
3.5 / 5.1
A/A
22-25-28-31
15.88 (5/8) / 9.52 (3/8)
34-36-39-41
66
840 (950) x 840 (950) x 298 (35)
27 / 6
Fed by Outdoor Unit
6
4
PLP-6BA
PAR-31MAA

PUHZ-SHW80VHA

PUHZ-SHW112VHA

PUHZ-SHW112YHA

51 / 50
68
120
950 x 330 + 30 x 1350
220-240v, 50Hz
Single
2.047 / 1.864
1.82 / 1.58
14
9.35 / 8.54 [30.2]
32
3
75
30
5.5

52 / 51
69
120
950 x 330 + 30 x 1350
220-240v, 50Hz
Single

52 / 51
69
134
950 x 330 + 30 x 1350
380-415, 50Hz
Three
2.677 / 2.786
2.37 / 2.37
3
4.40 / 4.43 [13.8]
16
5
75
30
5.5

2.677 / 2.786
2.37 / 2.37

14
11.94 / 11.84 [35.8]
40
3
75
30
5.5

Three Phase

PUHZ-SHW140YHA
Three Phase

52 / 51
69
134
950 x 330 + 30 x 1350
380-415, 50Hz
Three
3.879 / 4.449
3.45 / 3.78

3
5.62 / 5.72 [14.1]
16
5
75
30
5.5

Accessories

Product Dimensions

PLA-ZRP71/100/125BA

Indoor Units
PLP-6BA
grille for PLA-ZRP71-125BA

Upper View

PAC-SH53TM
Multi function casement PLA-ZRP71-125BA
for fresh air 100mm knockout or to hold the
high efficiency filter option

950

Ceiling hole

20~45

160

Suspension bolt pitch

20~45

Fresh air
intake hole

PLP-6BALM

20~45

860~910
810

Outdoor Units

860~910

Ceiling hole

Indoor power supply


terminal block(optional part)

620

840

Branch duct hole


950

Corner panel i-see sensor PLA-ZRP71-125BA

Remote controller
terminal block
Indoor unit/Outdoor
unit connecting
terminal block

Suspension bolt pitch

grille with filter lowering function PLA-ZRP71-125BA

PAC-SA1ME

605

160

PLP-6BAJ

(7.5)

grille and infra-red controller PLA-ZRP71-125BA

Branch duct hole

(7.5)

24

Models
20~45

187.5

System Control Units

160

90

Air outlet guide for PUHZ-SHW80-140vHA(YHA)

150

PAC-SG59SG

160
840

PLA-ZRP71BA
PLA-ZRP100BA
PLA-ZRP125BA

281 298 85

77

440

PAC-SA89TA
Remote on/off adaptor

PAC-SA88HA

Side View

Front View

Run/fault adapter
Suspension bolt
M10 or W3/8

Remote sensor

Refrigerant pipe (liquid)

PAR-31MAA
Remote controller

Drain pipe

100

100

90

Cut out hole


100

90

155

Keep approximately
10 to 15mm space
between unit ceiling
and ceiling slab.

175
Burring hole pitch

350

167

70
B

190

35

Ceiling
Grille

Power supply wire,


Indoor unit/Outdoor unit
connecting wire entry

156

105

Control wire entry

17 +50

Suspension bolt
lower edge

50~70

A/M-NET adaptor for PUHZ-SHW80-140vHA(YHA)

377

140

MELCloud WiFi interface

PAC-SF83MA

284

Refrigerant pipe (gas)

170

MAC-557IF

60

130

PAC-SE41TS

14- 2.8
150

Burring hole

Cut out hole

Note: additional accessories are available, please see the Optional Extras page at
the end of this section for the full range.

Air Conditioning
1.3.19 1.121

PLA-ZRP Zubadan Inverter Heat Pump

1.3.20

PKA-RP
Power Inverter
Heat Pump
Wall Mounted System

Our wide range of Power Inverters offer customers high seasonal efficiency, advanced control
options and quiet operation, whilst providing greater flexibility and ease of installation.

Key Features
Flat panel, compact indoor unit design
Adjustable louvres for uniform air distribution
Internal pipe connection to wall mounted unit for easy and neat installation

PKA-RP - INDOOR UNITS


CAPACITY (kW)

Heating (nominal)
Cooling (nominal)
Heating (UK)
Cooling (UK)

SHF (nominal & UK)


COP / EER (nominal)
SCOP / SEER (BS EN14825)
ErP ENERgY EFFICIENCY CLASS Heating/Cooling
AIRFLOW (m3/min)
Lo-Mi-Hi
PIPE SIZE mm (in)
Gas
Liquid
SOUND PRESSURE LEvEL (dBA)
SOUND POWER LEvEL (dBA)
DIMENSIONS (mm)
Width x Depth x Height
WEIgHT (kg)
ELECTRICAL SUPPLY
FUSE RATINg (BS88) - HRC (A)
INTERCONNECTINg CABLE No. Cores

PUHZ-ZRP - OUTDOOR UNITS


SOUND PRESSURE LEvEL (dBA) Heating/Cooling
SOUND POWER LEvEL (dBA) Cooling
WEIgHT (kg)
DIMENSIONS (mm) Width x Depth x Height
ELECTRICAL SUPPLY
PHASE
Heating/Cooling (nominal)
SYSTEM POWER
INPUT (kW)
Heating/Cooling (UK)
STARTINg CURRENT (A)
SYSTEM RUNNINg CURRENT (A) Heating/Cooling [MAX]
FUSE RATINg (BS88) - HRC (A)
MAINS CABLE No. Cores
MAX PIPE LENgTH (m)
MAX HEIgHT DIFFERENCE (m)
CHARgE R410A (kg) - 30m

3 Three Phase

PKA-RP35HAL

PKA-RP50HAL

PKA-RP60KAL

PKA-RP71KAL

PKA-RP100KAL

PKA-RP100KAL

4.1 (1.6-5.2)
3.6 (1.6-4.5)
3.5 (1.35-4.4)
3.3 (1.45-4.15)
0.81
3.83 / 3.83
3.9 / 5.7
A / A+
9-10.5-12
12.7 (1/2)
6.35 (1/4)
36-40-43
60
898 x 249 x 295
13
Fed by Outdoor Unit
6
4

5.0 (2.5-7.3)
4.6 (2.3-5.6)
4.25 (2.15-6.2)
4.23 (2.1-5.15)
0.72
3.33 / 3.26
4.0 / 5.3
A+ / A
9-10.5-12
12.7 (1/2)
6.35 (1/4)
36-40-43
60
898 x 249 x 295
13
Fed by Outdoor Unit
6
4

7.0 (2.8-8.2)
6.1 (2.7-6.7)
5.95 (2.4-6.95)
5.5 (2.5-6.15)
0.86
3.57 / 3.81
4.2 / 6.3
A+ / A++
18-20-22
15.88 (5/8)
9.52 (3/8)
39-42-45
64
1170 x 295 x 365
21
Fed by Outdoor Unit
6
4

8.0 (3.5-10.2)
7.1 (3.3-8.1)
6.8 (3.0-8.65)
6.55 (3.05-7.45)
0.78
3.65 / 3.94
4.3 / 6.5
A+ / A++
18-20-22
15.88 (5/8)
9.52 (3/8)
39-42-45
64
1170 x 295 x 365
21
Fed by Outdoor Unit
6
4

11.2 (4.5-14.0)
10.0 (4.9-11.4)
9.5 (3.85-11.9)
9.2 (4.5-10.5)
0.73
3.68 / 3.77
4.0 / 6.1
A+ / A++
20-23-26
15.88 (5/8)
9.52 (3/8)
41-45-49
65
1170 x 295 x 365
21
Fed by Outdoor Unit
6
4

11.2 (4.5-14.0)
10.0 (4.9-11.4)
9.5 (3.85-11.9)
9.2 (4.5-10.5)
0.73
3.68 / 3.77
4.0 / 6.0
A+ / A+
20-23-26
15.88 (5/8)
9.52 (3/8)
41-45-49
65
1170 x 295 x 365
21
Fed by Outdoor Unit
6
4

PUHZ-ZRP35VKA

PUHZ-ZRP50VKA

PUHZ-ZRP60VHA

PUHZ-ZRP71VHA

PUHZ-ZRP100VKA

46 / 44
65
43
809 x 300 x 630
220-240v, 50Hz
Single
1.07 / 0.94
0.84 / 0.91
4.0
4.22 / 3.94 [13.4]
16
3
50
30
2.2

46 / 44
65
46
809 x 300 x 630
220-240v, 50Hz
Single
1.50 / 1.41
1.25 / 1.28
5.0
7.16 / 6.59 [13.4]
16
3
50
30
2.4

48 / 47
67
67
950 x 330 + 30 x 943
220-240v, 50Hz
Single
1.96 / 1.60
1.42 / 1.67
5.0
9.23 / 8.11 [19.4]
25
3
50
30
3.5

48 / 47
67
67
950 x 330 + 30 x 943
220-240v, 50Hz
Single
2.19 / 1.80
1.60 / 1.86
6.0
8.75 / 7.79 [19.4]
25
3
50
30
3.5

51 / 49
69
116
1050 x 330 + 30 x 1338
220-240v, 50Hz
Single
3.04 / 2.65
2.36 / 2.58
12.0
11.46 / 11.44 [ 27.1]
32
3
75
30
5.0

PUHZ-ZRP100YKA 3
Three Phase

51 / 49
69
124
1050 x 330 + 30 x 1338
380-415v, 50Hz
Three
3.04 / 2.65
2.36 / 2.58
4.0
4.82 / 4.41 [8.6]
16
5
75
30
5.0

Accessories

Product Dimensions

PKA-RP35/50HAL

Indoor Units
S70 515 716
Terminal block
Upper View

S71 000 028


CN22 connector

Front View

Side View

192

387

197

PAC-SJ07SG

295

Outdoor Units
Air outlet guide for PUHZ-ZRP35-50vKA

PAC-SG59SG

599
55

688

Air outlet guide for PUHZ-ZRP60-71vHA

155

249

898

PAC-SH96SG
Air outlet guide for PUHZ-ZRP100vKA(YKA)

Product Dimensions
System Control Units

PKA-RP60/71/100KAL

Upper View

Front View

Side View

PAC-SA89TA
Remote on/off adaptor

Remote sensor

MAC-557IF

365

65.2

431.7

140.3

Run/fault adapter

PAC-SE41TS

423.7

11

PAC-SA88HA

74

(855)

241
1170

MELCloud WiFi interface

PAC-SJ19MA
A/M-NET adaptor for PUHZ-ZRP35-50vKA

PAC-SF83MA
A/M-NET adaptor for PUHZ-ZRP60-100vHA(vKA/YKA)

PAR-31MAA
Remote controller

Note: additional accessories are available, please see the Optional Extras page at
the end of this section for the full range.

Air Conditioning
1.3.21 1.121

PKA-RP Power Inverter Heat Pump

295

1.3.22

PKA-RP
Standard Inverter
Heat Pump
Wall Mounted System

Our Standard Inverter range offers customers all the features and benefits of inverter technology
whilst being cost effective.

Key Features

Flat panel, compact indoor unit design


Adjustable louvres for uniform air distribution
Internal pipe connection to wall mounted unit for easy and neat installation
3-phase Standard Inverter models also available

PKA-RP - INDOOR UNITS


CAPACITY (kW)

Heating (nominal)
Cooling (nominal)
Heating (UK)
Cooling (UK)

SHF (nominal & UK)


COP / EER (nominal)
SCOP / SEER (BS EN14825)
ErP ENERgY EFFICIENCY CLASS Heating/Cooling
AIRFLOW (m3/min)
Lo-Mi-Hi
PIPE SIZE mm (in)
Gas
Liquid
SOUND PRESSURE LEvEL (dBA) Lo-Mi-Hi
SOUND POWER LEvEL (dBA)
DIMENSIONS (mm)
Width x Depth x Height
WEIgHT (kg)
ELECTRICAL SUPPLY
FUSE RATINg (BS88) - HRC (A)
INTERCONNECTINg CABLE No. Cores

PUHZ-P - OUTDOOR UNITS


SOUND PRESSURE LEvEL (dBA) Heating/Cooling
SOUND POWER LEvEL (dBA) Cooling
WEIgHT (kg)
DIMENSIONS (mm) Width x Depth x Height
ELECTRICAL SUPPLY
PHASE
Heating/Cooling (nominal)
SYSTEM POWER
INPUT (kW)
Heating/Cooling (UK)
STARTINg CURRENT (A)
SYSTEM RUNNINg CURRENT (A) Heating/Cooling [MAX]
FUSE RATINg (BS88) - HRC (A)
MAINS CABLE No. Cores
MAX PIPE LENgTH (m)
MAX HEIgHT DIFFERENCE (m)
CHARgE R410A (kg) - 30m

3 Three Phase

PKA-RP100KAL

PKA-RP100KAL

11.2 (4.5-12.5)
9.4 (4.9-11.2)
9.5 (3.85-10.65)
8.65 (4.5-10.3)
0.75
3.21 / 3.01
3.8 / 4.8
A/B
20-23-26
15.88 (5/8)
9.52 (3/8)
41-45-49
65
1170 x 295 x 365
21
Fed by Outdoor Unit
6
4

11.2 (4.5-12.5)
9.4 (4.9-11.2)
9.5 (3.85-10.65)
8.65 (4.5-10.3)
0.75
3.21 / 3.01
3.8 / 4.8
A/B
20-23-26
15.88 (5/8)
9.52 (3/8)
41-45-49
65
1170 x 295 x 365
21
Fed by Outdoor Unit
6
4

PUHZ-P100VHA4

PUHZ-P100YHA2

54 / 50
70
75
950 x 330 + 30 x 943
220-240v, 50Hz
Single
3.49 / 3.12
3.11 / 2.65
12.0
15.20 / 14.55 [ 28.6]
32
3
50
30
3.0

54 / 50
70
77
950 x 330 + 30 x 943
380-415v, 50Hz
Three
3.49 / 3.12
3.11 / 2.65
4.0
5.76 / 5.50 [13.6]
16
5
50
30
3.0

Three Phase

Accessories

Product Dimensions

PKA-RP100KAL

Indoor Units
S70 515 716
Terminal block
Upper View

S71 000 028

Front View

Side View

CN22 connector

365
11

Air outlet guide for PUHZ-P100vHA4(YHA2)

431.7

140.3

PAC-SG59SG

65.2

423.7

Outdoor Units

74

(855)

241
1170

System Control Units


PAC-SA89TA
Remote on/off adaptor

PAC-SA88HA
Run/fault adapter

PAC-SE41TS
Remote sensor

MAC-557IF
MELCloud WiFi interface

PAC-SF83MA
A/M-NET adaptor for PUHZ-P100vHA4(YHA2)

PAR-31MAA
Remote controller

Note: additional accessories are available, please see the Optional Extras page at
the end of this section for the full range.

Air Conditioning
1.3.23 1.121

PKA-RP Standard Inverter Heat Pump

295

1.3.24

PKA-RP
Zubadan Inverter
Heat Pump
Wall Mounted System

The Mr Slim Zubadan Inverter heat pumps achieve an excellent heating performance
even when the outdoor air temperature is as low as -25C.

Key Features
Flat panel, compact indoor unit design
Stable heating performance - full heating capacity at -15C, a 30% capacity improvement over the next size up Power Inverter
Expanded heating operation - will work effectively even when the outdoor ambient air temperature is -25C
Stable operation - utilising the flash injection circuit, the Zubadan models have reduced defrost times
and can provide continuous heating for up to 150 mins
Quick start-up - At -20C, max heating capacity is achieved in about 20 mins, improving comfort levels

PKA-RP - INDOOR UNITS


CAPACITY (kW)

Heating (nominal)
Cooling (nominal)
Heating (UK)
Cooling (UK)

SHF (nominal & UK)


COP / EER (nominal)
SCOP / SEER
ErP ENERgY EFFICIENCY CLASS Heating/Cooling
AIRFLOW (m3/min)
Lo-Mi-Hi
PIPE SIZE mm (in)
Gas
Liquid
SOUND PRESSURE LEvEL (dBA) Lo-Mi-Hi
SOUND POWER LEvEL (dBA)
DIMENSIONS (mm)
Width x Depth x Height
WEIgHT (kg)
ELECTRICAL SUPPLY
FUSE RATINg (BS88) - HRC (A)
INTERCONNECTINg CABLE No. Cores

PUHZ-SHW - OUTDOOR UNITS


SOUND PRESSURE LEvEL (dBA) Heating/Cooling
SOUND POWER LEvEL (dBA) Heating/Cooling
WEIgHT (kg)
DIMENSIONS (mm) Width x Depth x Height
ELECTRICAL SUPPLY
PHASE
Heating/Cooling (nominal)
SYSTEM POWER
INPUT (kW)
Heating/Cooling (UK)
STARTINg CURRENT (A)
SYSTEM RUNNINg CURRENT (A) Heating/Cooling [MAX]
FUSE RATINg (BS88) - HRC (A)
MAINS CABLE No. Cores
MAX PIPE LENgTH (m)
MAX HEIgHT DIFFERENCE (m)
CHARgE R410A (kg) - 30m

3 Three Phase

PKA-RP100KAL

PKA-RP100KAL

11.2 (4.5-14.0)
10.0 (4.9-11.4)
11.1 (4.45-13.85)
9.2 (4.5-10.5)
0.73
3.61 / 3.42
3.8 / 5.2
A/A
20-23-26
15.88 (5/8)
9.52 (3/8)
41-45-49
65
1170 x 295 x 365
21
Fed by Outdoor Unit
6
4

11.2 (4.5-14.0)
10.0 (4.9-11.4)
11.1 (4.45-13.85)
9.2 (4.5-10.5)
0.73
3.61 / 3.42
3.8 / 5.2
A/A
20-23-26
15.88 (5/8)
9.52 (3/8)
41-45-49
65
1170 x 295 x 365
21
Fed by Outdoor Unit
6
4

PUHZ-SHW112VHA

PUHZ-SHW112YHA

52 / 51
69
120
950 x 330 + 30 x 1350
220-240v, 50Hz
Single
3.103 / 2.924
2.76 / 2.49
14
11.78 / 11.67 [35.6]
40
3
75
30
5.5

52 / 51
69
134
950 x 330 + 30 x 1350
380-415v, 50Hz
Three
3.103 / 2.924
2.76 / 2.49
3
4.24 / 4.26 [13.6]
16
5
75
30
5.5

Three Phase

Accessories

Product Dimensions

PKA-RP100KAL

Indoor Units
S70 515 716
Terminal block
Upper View

S71 000 028

Front View

Side View

CN22 connector

365
11

Air outlet guide for PUHZ-SHW112vHA(YHA)

431.7

140.3

PAC-SG59SG

65.2

423.7

Outdoor Units

74

System Control Units

(855)

241
1170

PAC-SA89TA
Remote on/off adaptor

PAC-SA88HA
Run/fault adapter

PAC-SE41TS
Remote sensor

MAC-557IF
MELCloud WiFi interface

PAC-SF83MA
A/M-NET adaptor for PUHZ-SHW112vHA(YHA)

PAR-31MAA
Remote controller

Note: additional accessories are available, please see the Optional Extras page at
the end of this section for the full range.

Air Conditioning
1.3.25 1.121

PKA-RP Zubadan Inverter Heat Pump

295

1.3.26

SEZ-KD
Inverter
Heat Pump

Designed for offices, restaurants and shops, the SEZ-KD series operates at low noise
levels. Its low unit height and lightweight design also help to make installation easier
and more convenient.

Ceiling Concealed
Ducted System

SEZ-KD-VAQ - INDOOR UNITS


CAPACITY (kW)

Heating (nominal)
Cooling (nominal)
Heating (UK)
Cooling (UK)

SHF (nominal & UK)


COP / EER (nominal)
SCOP / SEER (BS EN14825)
ErP ENERgY EFFICIENCY CLASS Heating/Cooling
AIRFLOW (m3/min)
Lo-Mi-Hi
PIPE SIZE mm (in)
Gas
Liquid
EXTERNAL STATIC PRESSURE (Pa)
SOUND PRESSURE LEvEL (dBA)
Lo-Mi-Hi
SOUND POWER LEvEL (dBA)
DIMENSIONS (mm)
Width x Depth x Height
WEIgHT (kg)
ELECTRICAL SUPPLY
FUSE RATINg (BS88) - HRC (A)
INTERCONNECTINg CABLE No. Cores

SUZ-KA-VA4 - OUTDOOR UNITS


SOUND PRESSURE LEvEL (dBA) Heating/Cooling
SOUND POWER LEvEL (dBA) Heating/Cooling
WEIgHT (kg)
DIMENSIONS (mm) Width x Depth x Height
ELECTRICAL SUPPLY
PHASE
Heating/Cooling (nominal)
SYSTEM POWER
INPUT (kW)
Heating/Cooling (UK)
STARTINg CURRENT (A)
SYSTEM RUNNINg CURRENT (A) Heating/Cooling [MAX]
FUSE RATINg (BS88) - HRC (A)
MAINS CABLE No. Cores
MAX PIPE LENgTH (m)
MAX HEIgHT DIFFERENCE (m)
CHARgE R410A (kg) - 7m

SEZ-KD25VAQ

SEZ-KD35VAQ

SEZ-KD50VAQ

SEZ-KD60VAQ

SEZ-KD71VAQ

2.9 (1.3-4.5)
2.5 (1.5-3.2)
2.47 (1.11-3.83)
2.30 (1.38-2.94)
0.8
3.61 / 3.42
3.8 / 5.2
A/A
6-7-9
9.52 (3/8)
6.35 (1/4)
5-15-35-50
22-25-29
50
790 x 700 x 200
18
Fed by Outdoor Unit
6
4

4.2 (1.7-5.0)
3.5 (1.4-3.9)
3.57 (1.45-4.25)
3.22 (1.29-3.59)
0.78
3.72 / 3.47
4.0 / 5.6
A+ / A+
7-9-11
9.52 (3/8)
6.35 (1/4)
5-15-35-50
23-28-33
53
990 x 700 x 200
21
Fed by Outdoor Unit
6
4

6.4 (1.7-7.2)
5.1 (2.3-5.6)
5.44 (1.45-6.12)
4.69 (2.12-5.15)
0.78
3.56 / 3.23
3.9 / 5.7
A / A+
10-13-15
12.7 (1/2)
6.35 (1/4)
5-15-35-50
29-33-36
57
990 x 700 x 200
23
Fed by Outdoor Unit
6
4

7.4 (2.5-8.0)
5.6 (2.3-6.3)
6.29 (2.13-6.80)
5.15 (2.12-5.80)
0.79
3.36 / 3.22
4.1 / 5.2
A+ / A
12-15-18
15.88 (5/8)
6.35 (1/4)
5-15-35-50
29-33-37
58
1190 x 700 x 200
27
Fed by Outdoor Unit
6
4

8.1 (2.6-10.4)
7.1 (2.8-8.3)
6.89 (2.21-8.84)
6.53 (2.58-7.64)
0.74
3.57 / 3.21
3.8 / 5.2
A/A
12-16-20
15.88 (5/8)
9.52 (3/8)
5-15-35-50
29-34-39
60
1190 x 700 x 200
27
Fed by Outdoor Unit
6
4

SUZ-KA25VA4

SUZ-KA35VA4

SUZ-KA50VA4

SUZ-KA60VA4

SUZ-KA71VA4

48 / 47
58
30
800 x 285 x 550
220-240v, 50Hz
Single
0.80 / 0.73
0.71 / 0.62
3.8
3.50 / 3.80 [7.4]
10
3
20
12
0.80

50 / 49
62
35
800 x 285 x 550
220-240v, 50Hz
Single
1.13 / 1.01
1.01 / 0.86
5.2
4.80 / 5.20 [8.7]
10
3
20
12
1.15

52 / 52
65
54
840 x 330 x 880
220-240v, 50Hz
Single
1.80 / 1.58
1.60 / 1.34
8.2
7.40 / 8.20 [12.7]
20
3
30
30
1.45

55 / 55
65
50
840 x 330 x 880
220-240v, 50Hz
Single
2.20 / 1.74
1.96 / 1.48
9.1
7.90 / 9.10 [14.7]
20
3
30
30
1.55

55 / 55
69
53
840 x 330 x 880
220-240v, 50Hz
Single
2.27 / 2.21
2.02 / 1.88
10.5
10.50 / 9.70 [17.0]
20
3
30
30
1.90

Accessories

Product Dimensions

SEZ-KD25/35/50/60/71VAQ

System Control Units


MAC-333IF
Interface for group control, run fault and connection
to M-NET System for SEZ-KD25-71vAQ

Front View

Upper View

Back View

MAC-397IF
20

Interface for group control and run/fault


SEZ-KD25-71vAQ

12

15

37

88

PAC-SA89TA

157.5
37 100

Remote on/off adaptor

PAC-SA88HA

Air
outlet

Air
inlet

MELCloud WiFi interface

H
100XJ=K

MAC-557IF

Remote sensor

D (Duct)

100X(E-1)=F

PAC-SE41TS

B (Suspension bolt pitch)

Run/fault adapter

PAR-31MAA

23

20
12

57

25

20
30

88

100

100

Remote controller

90

10
625 (Suspension bolt pitch)

49

Air filter

Suspension bolt hole

Side View

116

Model
SEZ-KD25VAQ
SEZ-KD35VAQ
SEZ-KD50VAQ
SEZ-KD60VAQ
SEZ-KD71VAQ

Terminal block
Terminal block (Indoor/outdoor connecting line)
(Remote controller transmission line)

70
270

Refrigerant piping
flare connection (gas)

200

102

23
25

Control box

100

150 (Duct)

700
677

23
10

170

Refrigerant piping
flare connection (liquid)

Drain pipe(Spontaneous draining)

A
700

B
752

C
798

D
660

900

952

998

860

1100 1152 1198 1060

F
600

G
800

H
660

J
5

K
500

L
16

800

1000

860

700

20

11

1000 1200 1060

900

24

E
7

Note: additional accessories are available, please see the Optional Extras page at
the end of this section for the full range.

Air Conditioning
1.3.27 1.121

SEZ-KD Inverter Heat Pump

1.3.28

PEAD-RP
Power Inverter
Heat Pump
(Single Phase)

Our wide range of Power Inverters offer customers high seasonal efficiency, advanced control
options and quiet operation, whilst providing greater flexibility and ease of installation.

Key Features
Reduced height - entire range only 250mm
Wider range of external static pressure settings across entire range
Drain pump included as standard

Ceiling Concealed
Ducted System
PEAD-RP - INDOOR UNITS
CAPACITY (kW)

Heating (nominal)
Cooling (nominal)
Heating (UK)
Cooling (UK)

SHF (nominal & UK)


COP / EER (nominal)
SCOP / SEER (BS EN14825)
ErP ENERgY EFFICIENCY CLASS Heating/Cooling
AIRFLOW (m3/min)
Lo-Mi-Hi
PIPE SIZE mm (in)
Gas
Liquid
EXTERNAL STATIC PRESSURE (Pa)
SOUND PRESSURE LEvEL (dBA)
Lo-Mi-Mi2-Mi3-Hi
SOUND POWER LEvEL (dBA)
DIMENSIONS (mm)
Width x Depth x Height
WEIgHT (kg)
ELECTRICAL SUPPLY
FUSE RATINg (BS88) - HRC (A)
INTERCONNECTINg CABLE No. Cores

PUHZ-ZRP - OUTDOOR UNITS


SOUND PRESSURE LEvEL (dBA) Heating/Cooling
SOUND POWER LEvEL (dBA) Heating/Cooling
WEIgHT (kg)
DIMENSIONS (mm) Width x Depth x Height
ELECTRICAL SUPPLY
PHASE
Heating/Cooling (nominal)
SYSTEM POWER
INPUT (kW)
Heating/Cooling (UK)
STARTINg CURRENT (A)
SYSTEM RUNNINg CURRENT (A) Heating/Cooling [MAX]
FUSE RATINg (BS88) - HRC (A)
MAINS CABLE No. Cores
MAX PIPE LENgTH (m)
MAX HEIgHT DIFFERENCE (m)
CHARgE R410A (kg) - 30m

PEAD-RP35JAQ

PEAD-RP50JAQ

PEAD-RP60JAQ

PEAD-RP71JAQ

PEAD-RP100JAQ

PEAD-RP125JAQ

PEAD-RP140JAQ

4.1 (1.6-5.2)
3.6 (1.6-4.5)
3.5 (1.35-4.4)
3.3 (1.45-4.15)
0.85
4.32 / 4.04
4.0 / 5.6
A+ / A+
10-12-14
12.7 (1/2)
6.35 (1/4)
35-50-70-100-150
23-27-30
52
900 x 732 x 250
26
Fed by Outdoor Unit
6
4

6.0 (2.5-7.3)
5.0 (2.3-5.6)
5.1 (2.15-6.2)
4.6 (2.1-5.15)
0.84
4.00 / 3.47
4.3 / 5.5
A+ / A
12-14.5-17
12.7 (1/2)
6.35 (1/4)
35-50-70-100-150
26-31-35
57
900 x 732 x 250
28
Fed by Outdoor Unit
6
4

7.0 (2.8-8.2)
6.1 (2.7-6.7)
5.95 (2.4-6.95)
5.5 (2.5-6.15)
0.83
3.91 / 3.70
4.1 / 5.8
A+ / A+
14.5-18-21
15.88 (5/8)
9.52 (3/8)
35-50-70-100-150
25-29-33
55
1100 x 732 x 250
33
Fed by Outdoor Unit
6
4

8.0 (3.5-10.2)
7.1 (3.3-8.1)
6.8 (3.0-8.65)
6.55 (3.05-7.45)
0.83
3.94 / 3.53
3.9 / 5.6
A / A+
17.5-21-25
15.88 (5/8)
9.52 (3/8)
35-50-70-100-150
26-30-34
57
1100 x 732 x 250
33
Fed by Outdoor Unit
6
4

11.2 (4.5-14.0)
10.0 (4.9-11.4)
9.5 (3.85-11.9)
9.2 (4.5-10.5)
0.82
4.31 / 3.80
4.2 / 5.6
A+ / A+
24-29-34
15.88 (5/8)
9.52 (3/8)
35-50-70-100-150
29-34-38
61
1400 x 732 x 250
41
Fed by Outdoor Unit
6
4

14.0 (5.0-16.0)
12.5 (5.5-14.0)
11.9 (4.25-13.6)
11.5 (5.05-12.9)
0.84
3.86 / 3.09
3.8 / 4.8
N/A
29.5-33.5-42
15.88 (5/8)
9.52 (3/8)
35-50-70-100-150
33-36-40
63
1400 x 732 x 250
43
Fed by Outdoor Unit
6
4

16.0 (5.7-18.0)
13.4 (6.2-15.3)
13.6 (4.85-15.3)
12.9 (5.7-14.1)
0.84
3.81 / 3.07
3.6 / 4.3
N/A
32-39-46
15.88 (5/8)
9.52 (3/8)
35-50-70-100-150
34-38-43
66
1600 x 732 x 250
47
Fed by Outdoor Unit
6
4

PUHZ-ZRP35VKA

PUHZ-ZRP50VKA

PUHZ-ZRP60VHA

PUHZ-ZRP71VHA

46 / 44
65
43
809 x 300 x 630
220-240v, 50Hz
Single
0.95 / 0.89
0.79 / 0.81
4.0
4.45 / 4.18 [14.1]
16
3
50
30
2.2

46 / 44
65
46
809 x 300 x 630
220-240v, 50Hz
Single
1.50 / 1.44
1.28 / 1.28
5.0
7.65 / 7.09 [14.4]
16
3
50
30
2.4

PUHZ-ZRP100VKA PUHZ-ZRP125VKA PUHZ-ZRP140VKA

51 / 49
48 / 47
48 / 47
52 / 50
52 / 50
69
67
67
70
70
116
67
67
116
119
950 x 330 + 30 x 943 950 x 330 + 30 x 943 1050 x 330 + 30 x 1338 1050 x 330 + 30 x 1338 1050 x 330 + 30 x 1338
220-240v, 50Hz
220-240v, 50Hz
220-240v, 50Hz
220-240v, 50Hz
220-240v, 50Hz
Single
Single
Single
Single
Single
2.03 / 2.01
1.79 / 1.65
2.60 / 2.63
3.63 / 4.05
4.20 / 4.36
1.79 / 1.73
1.47 / 1.52
2.34 / 2.21
3.60 / 3.09
3.88 / 3.57
6.0
5.0
12.0
12.0
12.0
9.56
/
8.64
[21.0]
9.76 / 8.68 [20.6]
12.53 / 12.55 [29.2]
17.95 / 18.9 [29.3]
22.69 / 21.28 [30.8]
25
25
32
32
40
3
3
3
3
3
50
50
75
75
75
30
30
30
30
30
3.5
3.5
5.0
5.0
5.0

Accessories

Product Dimensions

PEAD-RP35/50/60/71/100/125/140JAQ

Outdoor Units
PAC-SJ07SG
Air outlet guide for PUHZ-ZRP35-50vKA

Front View

PAC-SG59SG

Upper View

Air outlet guide for PUHZ-ZRP60-71vHA

PAC-SH96SG

Suspension bolt hole


4-14x30 Slot

15

Air outlet guide for PUHZ-ZRP100-140vKA

System Control Units


PAC-SA89TA

Air
inlet

Remote sensor

Air
outlet

Run/fault adapter

PAC-SE41TS

B(Suspension bolt pitch)

D (Duct)

PAC-SA88HA

100x(E-1)=F

Remote on/off adaptor

MAC-557IF
MELCloud WiFi interface
100

PAC-SJ19MA
30

A/M-NET adaptor for PUHZ-ZRP35-50vKA

PAR-31MAA

23

10

58

40

A/M-NET adaptor for PUHZ-ZRP60-140vHA(vKA)

57 20

PAC-SF83MA

643(Suspension bolt pitch)

57

Remote controller

Side View

Model

250

Drain pipe Drain pump


(O.D. 32)

217

122

238
10

33

23
40

32

100

178(Duct)

Terminal block
(Remote controller
transmission line)

732
700
41

Refrigerant piping
Flare connection (liquid)

PEAD-RP35,50JAQ
Control box

Refrigerant piping
Flare connection (gas)

136

67
356

Drain pipe
Terminal block
(Spontaneous draining) (Indoor/Outdoor
connecting line)

PEAD-RP60,71JAQ
PEAD-RP100,125JAQ
PEAD-RP140JAQ

A
900
1100
1400
1600

B
954
1154
1454
1654

C
D
1000 860
1200 1060
1500 1360
1700 1560

E
9
11
14
16

Note: additional accessories are available, please see the Optional Extras page at
the end of this section for the full range.

Air Conditioning
1.3.29 1.121

PEAD-RP Power Inverter Heat Pump (Single Phase)

F
800
1000
1300
1500

1.3.30

PEAD-RP
Power Inverter
Heat Pump
(Three Phase)

Our wide range of Power Inverters offer customers high seasonal efficiency, advanced control
options and quiet operation, whilst providing greater flexibility and ease of installation.

Key Features
Reduced height - entire range only 250mm
Wider range of external static pressure settings across entire range
Drain pump included as standard

Ceiling Concealed
Ducted System
PEAD-RP - INDOOR UNITS
CAPACITY (kW)

Heating (nominal)
Cooling (nominal)
Heating (UK)
Cooling (UK)

SHF (nominal & UK)


COP / EER (nominal)
SCOP / SEER (BS EN14825)
ErP ENERgY EFFICIENCY CLASS Heating/Cooling
AIRFLOW (m3/min)
Lo-Mi-Hi
PIPE SIZE mm (in)
Gas
Liquid
EXTERNAL STATIC PRESSURE (Pa)
SOUND PRESSURE LEvEL (dBA)
Lo-Mi-Hi
SOUND POWER LEvEL (dBA)
DIMENSIONS (mm)
Width x Depth x Height
WEIgHT (kg)
ELECTRICAL SUPPLY
FUSE RATINg (BS88) - HRC (A)
INTERCONNECTINg CABLE No. Cores

PUHZ-ZRP - OUTDOOR UNITS


SOUND PRESSURE LEvEL (dBA) Heating/Cooling
SOUND POWER LEvEL (dBA) Cooling
WEIgHT (kg)
DIMENSIONS (mm) Width x Depth x Height
ELECTRICAL SUPPLY
PHASE
Heating/Cooling (nominal)
SYSTEM POWER
INPUT (kW)
Heating/Cooling (UK)
STARTINg CURRENT (A)
SYSTEM RUNNINg CURRENT (A) Heating/Cooling [MAX]
FUSE RATINg (BS88) - HRC (A)
MAINS CABLE No. Cores
MAX PIPE LENgTH (m)
MAX HEIgHT DIFFERENCE (m)
CHARgE R410A (kg) - 30m

3 Three Phase

PEAD-RP100JAQ

PEAD-RP125JAQ

PEAD-RP140JAQ

11.2 (4.5-14.0)
10.0 (4.9-11.4)
9.5 (3.85-11.9)
9.2 (4.5-10.5)
0.82
4.31 / 3.80
4.2 / 5.5
A+ / A
24-29-34
15.88 (5/8)
9.52 (3/8)
35-50-70-100-150
29-34-38
61
1400 x 732 x 250
41
Fed by Outdoor Unit
6
4

14.0 (5.0-16.0)
12.5 (5.5-14.0)
11.9 (4.25-13.6)
11.5 (5.05-12.9)
0.84
3.86 / 3.09
3.8 / 4.8
N/A
29.5-33.5-42
15.88 (5/8)
9.52 (3/8)
35-50-70-100-150
33-36-40
63
1400 x 732 x 250
43
Fed by Outdoor Unit
6
4

16.0 (5.7-18.0)
13.4 (6.2-15.3)
13.6 (4.85-15.3)
12.3 (5.7-14.1)
0.84
3.81 / 3.07
3.6 / 4.2
N/A
32-39-46
15.88 (5/8)
9.52 (3/8)
35-50-70-100-150
34-38-43
66
1600 x 732 x 250
47
Fed by Outdoor Unit
6
4

PUHZ-ZRP100YKA
Three Phase

51 / 49
69
124
1050 x 330 + 30 x 1338
380-415v, 50Hz
Three
2.60 / 2.63
2.34 / 2.21
4.0
5.45 / 5.52 [10.7]
16
5
75
30
5.0

PUHZ-ZRP125YKA
Three Phase

52 / 50
70
126
1050 x 330 + 30 x 1338
380-415v, 50Hz
Three
3.63 / 4.05
3.60 / 3.09
4.0
7.83 / 8.24 [12.3]
16
5
75
30
5.0

PUHZ-ZRP140YKA
Three Phase

52 / 50
70
132
1050 x 330 + 30 x 1338
380-415v, 50Hz
Three
4.20 / 4.36
3.88 / 3.57
4.0
9.63 / 9.21 [13.8]
16
5
75
30
5.0

Accessories

Product Dimensions

PEAD-RP100/125/140JAQ

Outdoor Units
PAC-SH96SG
Air outlet guide for PUHZ-ZRP100-140YKA

Front View

System Control Units

Upper View
Suspension bolt hole
4-14x30 Slot

15

PAC-SA89TA
Remote on/off adaptor

PAC-SA88HA
Run/fault adapter

PAC-SE41TS

Air
inlet

A/M-NET adaptor for PUHZ-ZRP100-140YKA

PAR-31MAA

Air
outlet

D (Duct)

MELCloud WiFi interface

PAC-SF83MA

100x(E-1)=F

MAC-557IF

B(Suspension bolt pitch)

Remote sensor

23

10
643(Suspension bolt pitch)

57

Side View

Drain pipe Drain pump


(O.D. 32)

217

122

238
10

33

23
40

32

100

178(Duct)

Terminal block
(Remote controller
transmission line)

732
700
41

Refrigerant piping
Flare connection (liquid)

250

58

40

57 20

30

100

Remote controller

Control box
Refrigerant piping
Flare connection (gas)

136

67
356

Drain pipe
Terminal block
(Spontaneous draining) (Indoor/Outdoor
connecting line)

Model
PEAD-RP100,125JAQ
PEAD-RP140JAQ

A
B
C
D
1400 1454 1500 1360
1600 1654 1700 1560

E
14
16

Note: additional accessories are available, please see the Optional Extras page at
the end of this section for the full range.

Air Conditioning
1.3.31 1.121

PEAD-RP Power Inverter Heat Pump (Three Phase)

F
1300
1500

1.3.32

PEAD-RP
Standard Inverter
Heat Pump
(Single Phase)

Our Standard Inverter range offers customers all the features and benefits of inverter technology
whilst being cost effective.

Key Features
Reduced height - entire range only 250mm
Wider range of external static pressure settings across entire range
Drain pump included as standard

Ceiling Concealed
Ducted System
PEAD-RP - INDOOR UNITS

PEAD-RP35JAQ

PEAD-RP50JAQ

PEAD-RP60JAQ

PEAD-RP71JAQ

PEAD-RP100JAQ

PEAD-RP125JAQ

PEAD-RP140JAQ

4.1 (1.7-5.0)
3.6 (1.4-3.9)
3.49 (1.45-4.25)
3.31 (1.29-3.59)
0.85
3.69 / 3.42
4.0 / 5.5
A+ / A
10-12-14
9.52 (3/8)
6.35 (1/4)
35-50-70-100-150
23-27-30
52
900 x 732 x 250
26
Fed by Outdoor Unit
6
4

5.9 (1.7-7.2)
4.9 (2.3-5.6)
5.02 (1.45-6.12)
4.51 (2.12-5.15)
0.85
3.64 / 3.31
4.2 / 5.4
A+ / A
12-14.5-17
12.7 (1/2)
6.35 (1/4)
35-50-70-100-150
26-31-35
57
900 x 732 x 250
28
Fed by Outdoor Unit
6
4

7.0 (2.5-8.0)
5.7 (2.3-6.3)
5.95 (2.13-6.80)
5.24 (2.12-5.80)
0.86
3.63 / 3.41
4.0 / 5.6
A+ / A+
14.5-18-21
15.88 (5/8)
6.35 (1/4)
35-50-70-100-150
25-29-33
55
1100 x 732 x 250
33
Fed by Outdoor Unit
6
4

8.0 (2.6-10.2)
7.1 (2.8-8.1)
6.80 (2.21-8.67)
6.53 (2.58-7.45)
0.83
3.92 / 3.41
3.9 / 5.8
A / A+
17.5-21-25
15.88 (5/8)
9.52 (3/8)
35-50-70-100-150
26-30-34
57
1100 x 732 x 250
33
Fed by Outdoor Unit
6
4

11.2 (4.5-12.5)
9.4 (4.9-11.2)
9.5 (3.85-10.65)
8.65 (4.5-10.3)
0.85
3.61 / 3.01
3.8 / 4.6
A/B
24-29-34
15.88 (5/8)
9.52 (3/8)
35-50-70-100-150
29-34-38
61
1400 x 732 x 250
41
Fed by Outdoor Unit
6
4

14.0 (5.0-16.0)
12.3 (5.5-14.0)
11.9 (4.25-13.6)
11.3 (5.05-12.9)
0.85
3.62 / 2.91
3.9 / 3.5
N/A
29.5-35.5-42
15.88 (5/8)
9.52 (3/8)
35-50-70-100-150
33-36-40
63
1400 x 732 x 250
43
Fed by Outdoor Unit
6
4

16.0 (5.0-18.0)
13.6 (5.5-15.0)
13.6 (4.25-15.3)
12.5 (5.05-13.8)
0.84
3.61 / 3.01
3.7 / 3.2
N/A
32-39-46
15.88 (5/8)
9.52 (3/8)
35-50-70-100-150
34-38-43
66
1600 x 732 x 250
47
Fed by Outdoor Unit
6
4

SUZ-KA / PUHZ-P - OUTDOOR UNITS

SUZ-KA35VA4

SUZ-KA50VA4

SUZ-KA60VA4

SUZ-KA71VA4

PUHZ-P100VHA4

PUHZ-P125VHA3

PUHZ-P140VHA3

SOUND PRESSURE LEvEL (dBA) Heating/Cooling


SOUND POWER LEvEL (dBA) Cooling
WEIgHT (kg)
DIMENSIONS (mm) Width x Depth x Height
ELECTRICAL SUPPLY
PHASE
SYSTEM POWER
Heating/Cooling (nominal)
INPUT (kW)
Heating/Cooling (UK)
STARTINg CURRENT (A)
SYSTEM RUNNINg CURRENT (A) Heating/Cooling [MAX]
FUSE RATINg (BS88) - HRC (A)
MAINS CABLE No. Cores
MAX PIPE LENgTH (m)
MAX HEIgHT DIFFERENCE (m)
CHARgE R410A (kg)

50 / 49
62
35
800 x 285 x 550
220-240v, 50Hz
Single
1.11 / 1.50
0.99 / 1.28
5.1
4.90 / 5.10 [9.3]
16
3
20
12
1.15

52 / 52
65
54
840 x 330 x 880
220-240v, 50Hz
Single
1.62 / 1.48
1.44 / 1.26
7.3
6.90 / 7.30 [13.4]
20
3
30
30
1.45

55 / 55
65
50
840 x 330 x 880
220-240v, 50Hz
Single
1.93 / 1.67
1.72 / 1.42
8.6
7.50 / 8.60 [15.6]
20
3
30
30
1.55

55 / 55
69
53
840 x 330 x 880
220-240v, 50Hz
Single
2.04 / 2.08
1.82 / 1.77
9.3
9.30 / 9.10 [18.1]
20
3
30
30
1.90

CAPACITY (kW)

Heating (nominal)
Cooling (nominal)
Heating (UK)
Cooling (UK)

SHF (nominal & UK)


COP / EER (nominal)
SCOP / SEER (BS EN14825)
ErP ENERgY EFFICIENCY CLASS Heating/Cooling
AIRFLOW (m3/min)
Lo-Mi-Hi
PIPE SIZE mm (in)
Gas
Liquid
EXTERNAL STATIC PRESSURE (Pa)
SOUND PRESSURE LEvEL (dBA)
Lo-Mi-Hi
SOUND POWER LEvEL (dBA)
DIMENSIONS (mm)
Width x Depth x Height
WEIgHT (kg)
ELECTRICAL SUPPLY
FUSE RATINg (BS88) - HRC (A)
INTERCONNECTINg CABLE No. Cores

Notes: All units charged to 7m (35-71), 30m (100-140) pipe length.

54 / 50
55 / 51
56 / 52
70
71
73
75
99
99
950 x 330 + 30 x 943 950 x 330 + 30 x 1350 950 x 330 + 30 x 1350
220-240v, 50Hz
220-240v, 50Hz
220-240v, 50Hz
Single
Single
Single
3.103 / 3.120
3.870 / 4.220
4.430 / 4.520
2.76 / 2.58
3.44 / 3.59
3.94 / 3.84
12.0
15.0
15.0
16.27 / 15.55 [30.65] 19.03 / 19.66 [30.76] 23.8 / 24.97 [32.28]
32
32
40
3
3
3
50
50
50
30
30
30
3.0
4.5
4.5

Accessories

Product Dimensions

PEAD-RP35/50/60/71/100/125/140JAQ

Outdoor Units
PAC-SG59SG
Air outlet guide for PUHZ-P100-140vHA4(vHA3)

Front View

System Control Units

Upper View
Suspension bolt hole
4-14x30 Slot

15

PAC-SA89TA
Remote on/off adaptor

PAC-SA88HA
Run/fault adapter

PAC-SE41TS

Air
inlet

A/M-NET adaptor for PUHZ-P100-140vHA4(vHA3)

Air
outlet

D (Duct)

MELCloud WiFi interface

PAC-SF83MA

B(Suspension bolt pitch)

MAC-557IF

100x(E-1)=F

Remote sensor

PAR-31MAA

23

10
643(Suspension bolt pitch)

57

Side View

Drain pipe Drain pump


(O.D. 32)

217

122

238
10

33

23
40

32

100

178(Duct)

Terminal block
(Remote controller
transmission line)

732
700
41

Refrigerant piping
Flare connection (liquid)

Model

250

58

40

57 20

30

100

Remote controller

PEAD-RP35,50JAQ
Control box

Refrigerant piping
Flare connection (gas)

136

67
356

Drain pipe
Terminal block
(Spontaneous draining) (Indoor/Outdoor
connecting line)

PEAD-RP60,71JAQ
PEAD-RP100,125JAQ
PEAD-RP140JAQ

A
900
1100
1400
1600

B
954
1154
1454
1654

C
D
1000 860
1200 1060
1500 1360
1700 1560

E
9
11
14
16

F
800
1000
1300
1500

Note: additional accessories are available, please see the Optional Extras page at
the end of this section for the full range.

Air Conditioning
1.3.33 1.121

PEAD-RP Standard Inverter Heat Pump (Single Phase)

1.3.34

PEAD-RP
Standard Inverter
Heat Pump
(Three Phase)

Our Standard Inverter range offers customers all the features and benefits of inverter technology
whilst being cost effective.

Key Features
Reduced height - entire range only 250mm
Wider range of external static pressure settings across entire range
Drain pump included as standard

Ceiling Concealed
Ducted System
PEAD-RP - INDOOR UNITS
CAPACITY (kW)

Heating (nominal)
Cooling (nominal)
Heating (UK)
Cooling (UK)

SHF (nominal & UK)


COP / EER (nominal)
SCOP / SEER (BS EN14825)
ErP ENERgY EFFICIENCY CLASS Heating/Cooling
AIRFLOW (m3/min)
Lo-Mi-Hi
PIPE SIZE mm (in)
Gas
Liquid
EXTERNAL STATIC PRESSURE (Pa)
SOUND PRESSURE LEvEL (dBA)
Lo-Mi-Hi
SOUND POWER LEvEL (dBA)
DIMENSIONS (mm)
Width x Depth x Height
WEIgHT (kg)
ELECTRICAL SUPPLY
FUSE RATINg (BS88) - HRC (A)
INTERCONNECTINg CABLE No. Cores

PUHZ-P - OUTDOOR UNITS


SOUND PRESSURE LEvEL (dBA) Heating/Cooling
SOUND POWER LEvEL (dBA) Cooling
WEIgHT (kg)
DIMENSIONS (mm) Width x Depth x Height
ELECTRICAL SUPPLY
PHASE
Heating/Cooling (nominal)
SYSTEM POWER
INPUT (kW)
Heating/Cooling (UK)
STARTINg CURRENT (A)
SYSTEM RUNNINg CURRENT (A) Heating/Cooling [MAX]
FUSE RATINg (BS88) - HRC (A)
MAINS CABLE No. Cores
MAX PIPE LENgTH (m)
MAX HEIgHT DIFFERENCE (m)
CHARgE R410A (kg)

3 Three Phase

PEAD-RP100JAQ

PEAD-RP125JAQ

PEAD-RP140JAQ

11.2 (4.5-12.5)
9.4 (4.9-11.2)
9.5 (3.85-10.65)
8.65 (4.5-10.3)
0.85
3.61 / 3.01
3.8 / 4.6
A/B
24-29-34
15.88 (5/8)
9.52 (3/8)
35-50-70-100-150
29-34-38
61
1400 x 732 x 250
41
Fed by Outdoor Unit
6
4

14.0 (5.0-16.0)
12.3 (5.5-14.0)
11.9 (4.25-13.6)
11.3 (5.05-12.9)
0.85
3.62 / 2.91
3.9 / 3.5
N/A
29.5-35.5-42
15.88 (5/8)
9.52 (3/8)
35-50-70-100-150
33-36-40
63
1400 x 732 x 250
43
Fed by Outdoor Unit
6
4

16.0 (5.0-18.0)
13.6 (5.5-15.0)
13.6 (4.25-15.3)
12.5 (5.05-13.8)
0.84
3.61 / 3.01
3.7 / 3.2
N/A
32-39-46
15.88 (5/8)
9.52 (3/8)
35-50-70-100-150
34-38-43
66
1600 x 732 x 250
47
Fed by Outdoor Unit
6
4

PUHZ-P100YHA2
Three Phase

54 / 50
70
77
950 x 330 + 30 x 943
380-415v, 50Hz
Three
3.103 / 3.120
2.76 / 2.65
4.0
6.83 / 6.68 [15.65]
16
5
50
30
3.0

Notes: All units charged to 30m (100-140) pipe length.

PUHZ-P125YHA
Three Phase

55 / 51
71
101
950 x 330 + 30 x 1350
380-415v, 50Hz
Three
3.870 / 4.220
3.44 / 3.59
5.0
8.38 / 8.58 [15.76]
16
5
50
30
4.5

PUHZ-P140YHA
Three Phase

56 / 52
73
101
950 x 330 + 30 x 1350
380-415v, 50Hz
Three
4.430 / 4.520
3.94 / 3.84
5.0
10.07 / 10.52 [15.78]
16
5
50
30
4.5

Accessories

Product Dimensions

PEAD-RP100/125/140JAQ

Outdoor Units
PAC-SG59SG
Air outlet guide for PUHZ-P100-140YHA2(YHA)

Front View

System Control Units

Upper View
Suspension bolt hole
4-14x30 Slot

15

PAC-SA89TA
Remote on/off adaptor

PAC-SA88HA
Run/fault adapter

PAC-SE41TS

Air
inlet

A/M-NET adaptor for PUHZ-P100-140YHA2(YHA)

PAR-31MAA

Air
outlet

D (Duct)

MELCloud WiFi interface

PAC-SF83MA

B(Suspension bolt pitch)

MAC-557IF

100x(E-1)=F

Remote sensor

23

10
643(Suspension bolt pitch)

57

Side View

Drain pipe Drain pump


(O.D. 32)

217

122

238
10

33

23
40

32

100

178(Duct)

Terminal block
(Remote controller
transmission line)

732
700
41

Refrigerant piping
Flare connection (liquid)

250

58

40

57 20

30

100

Remote controller

Control box
Refrigerant piping
Flare connection (gas)

136

67
356

Drain pipe
Terminal block
(Spontaneous draining) (Indoor/Outdoor
connecting line)

Model
PEAD-RP100,125JAQ
PEAD-RP140JAQ

A
B
C
D
1400 1454 1500 1360
1600 1654 1700 1560

E
14
16

F
1300
1500

Note: additional accessories are available, please see the Optional Extras page at
the end of this section for the full range.

Air Conditioning
1.3.35 1.121

PEAD-RP Standard Inverter Heat Pump (Three Phase)

1.3.36

PEAD-RP
Zubadan Inverter
Heat Pump
Ceiling Concealed
Ducted System

The Mr Slim Zubadan Inverter heat pumps achieve an excellent heating performance
even when the outdoor air temperature is as low as -25C.

Key Features
Stable heating performance - full heating capacity at -15C, a 30% capacity improvement over the next size up Power Inverter
Expanded heating operation - will work effectively even when the outdoor ambient air temperature is -25C
Stable operation - utilising a flash injection circuit, the Zubadan models have reduced defrost times and can provide
continuous heating for up to 150 mins
Quick start-up - At -20C, max heating capacity is achieved in about 20 mins, improving comfort levels

PEAD-RP - INDOOR UNITS


CAPACITY (kW)

Heating (nominal)
Cooling (nominal)
Heating (UK)
Cooling (UK)

SHF (nominal & UK)


COP / EER (nominal)
SCOP / SEER (BS EN14825)
ErP ENERgY EFFICIENCY CLASS Heating/Cooling
AIRFLOW (m3/min)
Lo-Mi-Hi
PIPE SIZE mm (in)
Gas
Liquid
EXTERNAL STATIC PRESSURE (Pa)
SOUND PRESSURE LEvEL (dBA)
Lo-Mi-Hi
SOUND POWER LEvEL (dBA)
DIMENSIONS (mm)
Width x Depth x Height
WEIgHT (kg)
ELECTRICAL SUPPLY
FUSE RATINg (BS88) - HRC (A)
INTERCONNECTINg CABLE No. Cores

PUHZ-SHW - OUTDOOR UNITS


SOUND PRESSURE LEvEL (dBA) Heating/Cooling
SOUND POWER LEvEL (dBA) Cooling
WEIgHT (kg)
DIMENSIONS (mm) Width x Depth x Height
ELECTRICAL SUPPLY
PHASE
Heating/Cooling (nominal)
SYSTEM POWER
INPUT (kW)
Heating/Cooling (UK)
STARTINg CURRENT (A)
SYSTEM RUNNINg CURRENT (A) Heating/Cooling [MAX]
FUSE RATINg (BS88) - HRC (A)
MAINS CABLE No. Cores
MAX PIPE LENgTH (m)
MAX HEIgHT DIFFERENCE (m)
CHARgE R410A (kg) - 30m

3 Three Phase

PEAD-RP71JAQ

PEAD-RP100JAQ

PEAD-RP100JAQ

PEAD-RP125JAQ

8.0 (4.5-10.2)
7.1 (4.9-8.1)
7.9 (3.45-10.1)
6.55 (3.05-7.45)
0.83
3.61 / 3.74
3.7 / 4.6
A/B
17.5-21.0-25.0
15.88 (5/8)
9.52 (3/8)
35-50-70-100-150
26-30-34
57
1100 x 732 x 250
33
Fed by Outdoor Unit
6
4

11.2 (4.5-14.0)
10.0 (4.9-11.4)
11.1 (4.45-13.85)
9.2 (4.5-10.5)
0.82
3.61 / 3.42
3.8 / 4.8
A/B
24.0-29.0-34.0
15.88 (5/8)
9.52 (3/8)
35-50-70-100-150
29-34-38
61
1400 x 732 x 250
41
Fed by Outdoor Unit
6
4

11.2 (4.5-14.0)
10.0 (4.9-11.4)
11.1 (4.45-13.85)
9.2 (4.5-10.5)
0.82
3.61 / 3.42
3.8 / 4.8
A/B
24.0-29.0-34.0
15.88 (5/8)
9.52 (3/8)
35-50-70-100-150
29-34-38
61
1400 x 732 x 250
41
Fed by Outdoor Unit
6
4

14.0 (5.0-16.0)
12.5 (5.5-14.0)
13.85 (4.95-15.85)
11.5 (5.05-12.9)
0.84
3.61 / 3.21
3.6 / 4.8
A/B
29.5-35.5-42.0
15.88 (5/8)
9.52 (3/8)
35-50-70-100-150
33-36-40
63
1400 x 732 x 250
43
Fed by Outdoor Unit
6
4

PUHZ-SHW80VHA

PUHZ-SHW112VHA

PUHZ-SHW112YHA

51 / 50
68
120
950 x 330 + 30 x 1350
220-240v, 50Hz
Single
2.217 / 1.879
1.97 / 1.59
14
10.11 / 9.37 [31.5]
32
3
75
30
5.5

52 / 51
69
120
950 x 330 + 30 x 1350
220-240v, 50Hz
Single
3.103 / 2.904
2.76 / 2.47
14
12.85 / 12.78 [37.8]
40
3
75
30
5.5

52 / 51
69
134
950 x 330 + 30 x 1350
380-415, 50Hz
Three
3.103 / 2.904
2.76 / 2.47
3
5.31 / 5.37 [15.8]
16
5
75
30
5.5

Three Phase

PUHZ-SHW140YHA
Three Phase

52 / 51
69
134
950 x 330 + 30 x 1350
380-415, 50Hz
Three
3.879 / 3.875
3.45 / 3.29
3
7.20 / 7.32 [15.8]
16
5
75
30
5.5

Accessories

Product Dimensions

PEAD-RP71/100/125JAQ

Outdoor Units
PAC-SG59SG
Air outlet guide for PUHZ-SHW80-140vHA(YHA)

Front View

System Control Units

Upper View
Suspension bolt hole
4-14x30 Slot

15

PAC-SA89TA
Remote on/off adaptor

PAC-SA88HA
Run/fault adapter

PAC-SE41TS

Air
inlet

A/M-NET adaptor for PUHZ-SHW80-140vHA(YHA)

PAR-31MAA

Air
outlet

D (Duct)

100x(E-1)=F

MELCloud WiFi interface

PAC-SF83MA

B(Suspension bolt pitch)

Remote sensor

MAC-557IF

23

10
643(Suspension bolt pitch)

57

Side View

Drain pipe Drain pump


(O.D. 32)

217

122

238
10

33

23
40

32

100

178(Duct)

Terminal block
(Remote controller
transmission line)

732
700
41

Refrigerant piping
Flare connection (liquid)

250

58

40

57 20

30

100

Remote controller

Control box
Refrigerant piping
Flare connection (gas)

136

67
356

Drain pipe
Terminal block
(Spontaneous draining) (Indoor/Outdoor
connecting line)

Model
PEAD-RP71JAQ
PEAD-RP100,125JAQ

A
B
D
C
1100 1154 1200 1060
1400 1454 1500 1360

Note: additional accessories are available, please see the Optional Extras page at
the end of this section for the full range.

Air Conditioning
1.3.37 1.121

PEAD-RP Zubadan Inverter Heat Pump

E
11
14

F
1000
1300

1.3.38

PEA-RP
Power Inverter
Heat Pump

Our wide range of Power Inverters offer customers high seasonal efficiency, advanced control
options and quiet operation, whilst providing greater flexibility and ease of installation.

Key Features
Static pressure of up to 150Pa

Large Capacity Ceiling


Concealed Ducted System

PEA-RP - INDOOR UNITS


CAPACITY (kW)

Heating (nominal)
Cooling (nominal)
Heating (UK)
Cooling (UK)

SHF (nominal & UK)


COP / EER (nominal)
ENERgY LABEL
Heating/Cooling (nominal)
Lo-Hi
AIRFLOW (m3/min)
PIPE SIZE mm (in)
Gas
Liquid
EXTERNAL STATIC PRESSURE (Pa)
SOUND PRESSURE LEvEL (dBA) (50Pa) Lo-Hi
DIMENSIONS (mm) Width x Depth x Height
WEIgHT (kg)
ELECTRICAL SUPPLY
PHASE
POWER INPUT (kW) nominal / UK
STARTINg CURRENT (A)
RUNNINg CURRENT (A) [MAX]
FUSE RATINg (BS88) - HRC (A)
MAINS CABLE No. Cores
INTERCONNECTINg CABLE No. Cores

PUHZ-RP - OUTDOOR UNITS


SOUND PRESSURE LEvEL (dBA) Heating/Cooling
WEIgHT (kg)
DIMENSIONS (mm) Width x Depth x Height
ELECTRICAL SUPPLY
PHASE
SYSTEM POWER
Heating/Cooling (nominal)
INPUT (kW)
Heating/Cooling (UK)
STARTINg CURRENT (A)
RUNNINg CURRENT (A) Heating/Cooling [MAX]
FUSE RATINg (BS88) - HRC (A)
MAINS CABLE No. Cores
MAX PIPE LENgTH (m)
MAX HEIgHT DIFFERENCE (m)
CHARgE R410A (kg) - 30m

3 Three Phase

PEA-RP200GAQ
Three Phase

22.4 (9.5-25.0)
19.0 (9.0-22.4)
19.05 (8.1-21.25)
17.5 (8.3-20.6)
0.81
3.45 / 2.84
B/C
52-65
28.58 (1 1/8)
9.52 (3/8)
150
48-51
1400 x 634 x 400
70
380-415v, 50Hz
Three
1.00 / 0.89
5.6
2.0 [2.4]
6
5
3

PUHZ-RP200YKA
Three Phase

59 / 58
135
1050 x 330 + 30 x 1338
380-415v, 50Hz
Three
6.5 / 6.7
5.79 / 5.7
5
8.63 / 8.94 [19]
20
5
120
30
7.1

PEA-RP250GAQ
Three Phase

27.0 (12.5-31.5)
22.0 (11.2-28.0)
22.95 (10.65-26.8)
20.25 (10.3-25.75)
0.86
3.29 / 2.64
C/D
64-80
28.58 (1 1/8)
12.7 (1/2)
150
49-52
1600 x 634 x 400
77
380-415v, 50Hz
Three
1.18 / 1.05
5.6
2.3 [2.8]
6
5
3

PUHZ-RP250YKA
Three Phase

59 / 58
141
1050 x 330 + 30 x 1338
380-415v, 50Hz
Three
8.2 / 8.34
7.3 / 7.09
5
11.01 / 11.23 [21]
25
5
120
30
7.7

PEA-RP400GAQ
Three Phase

44.8 (18.0-50.0)
38.0 (18.0-44.8)
38.1 (15.3-42.5)
34.95 (16.55-41.2)
0.75
3.57 / 2.93
B/C
120
28.58 (1 1/8) x2
9.52 (3/8) x2
150
52
1947 x 764 x 595
130
380-415v, 50Hz
Three
1.55 / 1.38
8.7
3.8 [4.6]
10
5
3

PUHZ-RP200YKA x2
Three Phase

59 / 58
135
1050 x 330 + 30 x 1338
380-415v, 50Hz
Three
12.55 / 12.95
11.17 / 11.01
5
8.63 / 8.94 [19]
20
5
120
30
7.1

PEA-RP500GAQ
Three Phase

54.0 (25.0-63.0)
44.0 (22.4-56.0)
45.9 (21.25-53.55)
40.5 (20.6-51.5)
0.77
3.20 / 2.56
D/E
160
28.58 (1 1/8) x2
12.7 (1/2) x2
150
53
1947 x 764 x 595
133
380-415v, 50Hz
Three
2.84 / 2.53
10
5.4 [6.5]
10
5
3

PUHZ-RP250YKA x2
Three Phase

59 / 58
141
1050 x 330 + 30 x 1338
380-415v, 50Hz
Three
16.88 / 17.16
15.02 / 14.59
5
11.01 / 11.23 [21]
25
5
120
30
7.7

Accessories

Product Dimensions

PEA-RP200GAQ

Outdoor Units
Front View

Upper View
1102
8x130(=1040)
130

Run/fault adapter

Return air

7x130(=910)

4- 12

45

PAC-SF83MA

39

565

Product Dimensions

95
250

Supply air
1284

Drain

Refrigerant pipe
(liquid)

PAC-SE41TS
Remote sensor

40
105

400

131

130

1400
1340
1260
1000

11

Fresh-air
intake duct 45
flange

10

40

PAC-SA88HA

155

376

20
22- 3.1

40

54
10
100 100 25

199

1300

634
530

25

462

20

Remote on/off adaptor

Return air
sensor
50
Refrigerant pipe
10
(gas)
73

10

100

24- 3 Holes

Control box

PAC-SA89TA

Return-air
duct flange

262

42

System Control Units

Back View

34
31

22
330
145 144
130 130 35

124
31

89
35

Air outlet guide for PUHZ-RP200-250YKA

200

PAC-SH96SG

PEA-RP250GAQ

A/M-NET adaptor for PUHZ-P200-250YHA3

Front View
124
66

1302
9X130(=1170)
130

7x130(=910)

45

39

33
29

Air Conditioning
1.3.39 1.121

8X130(=1040)

95
250

400
40

1947
1880
1800
1125

340

595

570

Supply air

Drain
Refrigerant pipe

(liquid)

PEA-RP Power Inverter Heat Pump

22

A
700

40
280
188

395

40

120

39

42.5

50
10

130 130

525

764
664
Return air sensor
(2 places)

40

4- 15

Return air

22.5

130
42.5

10

59

24- 3.1

Fresh-air intake
duct flange

320

20

141

425

Control box
1840

50
10

22
22.5
81

203

10

100

Return-air
duct flange

36- 3 HOLES

Back View

Refrigerant pipe (gas)

130

4X120(=480)
117 156 117

1618
12X130(=1560)

20

1484

Upper View

102

149
29

Supply air

PEA-RP400/500GAQ

Front View
45

40
205

Drain

Refrigerant pipe
(Liquid)

Product Dimensions

565

376

Return air
4- 12

255

1600
1540
1460
1000

11

130

54
10
100 100 25

131
10

40

Fresh-air
intake duct 45
flange

73

20
22- 3.1

40

25

199

1500

634
530
Return air
sensor

262

462

20

Refrigerant pipe
50
(gas)
10
330
22
145 144
130 130 35

100

10

Return air
duct flange

26- 3 Holes

Control box

Note: additional accessories are available, please see the Optional Extras page at
the end of this section for the full range.

Back View

34
66

42

89
35

Remote controller

Upper View

200

PAR-31MAA

1824

1.3.40

PEA-RP
Standard Inverter
Heat Pump

Our Standard large capacity range offers customers all the features and benefits of inverter technology
with high static pressure of up to 150Pa whilst being cost effective.

Key Features
Static pressure of up to 150Pa

Large Capacity Ceiling


Concealed Ducted System

PEA-RP - INDOOR UNITS


CAPACITY (kW)

Heating (nominal)
Cooling (nominal)
Heating (UK)
Cooling (UK)

SHF (nominal & UK)


COP / EER (nominal)
ENERgY LABEL
Heating/Cooling (nominal)
AIRFLOW (m3/min)
Lo-Hi
PIPE SIZE mm (in)
Gas
Liquid
EXTERNAL STATIC PRESSURE (Pa)
SOUND PRESSURE LEvEL (dBA) (50Pa) Lo-Hi
DIMENSIONS (mm) Width x Depth x Height
WEIgHT (kg)
ELECTRICAL SUPPLY
PHASE
POWER INPUT (kW) nominal / UK
STARTINg CURRENT (A)
RUNNINg CURRENT (A) [MAX]
FUSE RATINg (BS88) - HRC (A)
MAINS CABLE No. Cores
INTERCONNECTINg CABLE No. Cores

PUHZ-P - OUTDOOR UNITS


SOUND PRESSURE LEvEL (dBA) Heating/Cooling
WEIgHT (kg)
DIMENSIONS (mm) Width x Depth x Height
ELECTRICAL SUPPLY
PHASE
Heating/Cooling (nominal)
SYSTEM POWER
INPUT (kW)
Heating/Cooling (UK)
STARTINg CURRENT (A)
RUNNINg CURRENT (A) Heating/Cooling [MAX]
FUSE RATINg (BS88) - HRC (A)
MAINS CABLE No. Cores
MAX PIPE LENgTH (m)
MAX HEIgHT DIFFERENCE (m)
CHARgE R410A (kg) - 30m

3 Three Phase

PEA-RP200GAQ
Three Phase

Three Phase

59 / 59
126
950 x 330+30 x 1350
380-415v, 50Hz
Three
7.36 / 7.21
6.55 / 6.13
5
9.88 / 9.47 [19]
20
5
70
30
5.8

Three Phase

PUHZ-P250YHA3
Three Phase

59 / 59
135
950 x 330+30 x 1350
380-415v, 50Hz
Three
8.47 / 8.44
7.54 / 7.17
5
12.0 / 11.0 [21]
25
5
70
30
7.1

PEA-RP400GAQ
Three Phase

PUHZ-P200YHA3 x2
Three Phase

59 / 59
126
950 x 330+30 x 1350
380-415v, 50Hz
Three
14.27 / 13.97
12.7 / 11.88
5
9.88 / 9.47 [19]
20
5
70 per outdoor
30
5.8

PEA-RP500GAQ
Three Phase

54.0 (25.0-63.0)
44.0 (22.4-56.0)
45.9 (21.25-53.55)
40.5 (20.6-51.5)
0.77
3.10 / 2.53
D/E
160
28.58 (1 1/8) x2
12.7 (1/2) x2
150
53
1947 x 764 x 595
133
380-415v, 50Hz
Three
2.84 / 2.53
10
5.4 [ 6.5]
10
5
3

44.8 (19.0-50.0)
38.0 (18.0-44.8)
38.1 (16.15-42.5)
34.95 (16.55-41.2)
0.75
3.14 / 2.72
D/D
120
28.58 (1 1/8) x2
9.52 (3/8) x2
150
52
1947 x 764 x 595
130
380-415v, 50Hz
Three
1.55 / 1.38
8.7
3.8 [4.6]
10
5
3

27.0 (12.5-31.5)
22.0 (11.2-28.0)
22.95 (10.65-26.8)
20.25 (10.3-25.75)
0.86
3.19 / 2.61
D/D
64-80
28.58 (1 1/8)
12.7 (1/2)
150
49-52
1600 x 634 x 400
77
380-415v, 50Hz
Three
1.18 / 1.05
5.6
2.3 [2.8]
6
5
3

22.4 (9.5-25.0)
19.0 (9.0-22.4)
19.05 (8.1-21.25)
17.5 (8.3-20.6)
0.81
3.04 / 2.64
D/D
52-65
28.58 (1 1/8)
9.52 (3/8)
150
48-51
1400 x 634 x 400
70
380-415v, 50Hz
Three
1.00 / 0.89
5.6
2.0 [2.4]
6
5
3

PUHZ-P200YHA3

PEA-RP250GAQ

PUHZ-P250YHA3 x2
Three Phase

59 / 59
135
950 x 330+30 x 1350
380-415v, 50Hz
Three
17.42 / 17.36
15.5 / 14.76
5
12.0 / 11.0 [21]
25
5
70 per outdoor
30
7.1

Accessories

Product Dimensions

PEA-RP200GAQ

Outdoor Units
Front View

Upper View
1102
8x130(=1040)
130

Run/fault adapter

Return air

7x130(=910)

4- 12

45

PAC-SF83MA

39

565

Product Dimensions

95
250

Supply air
1284

Drain

Refrigerant pipe
(liquid)

PAC-SE41TS
Remote sensor

40
105

400

131

130

1400
1340
1260
1000

11

Fresh-air
intake duct 45
flange

10

40

PAC-SA88HA

155

376

20
22- 3.1

40

54
10
100 100 25

199

1300

634
530

25

462

20

Remote on/off adaptor

Return air
sensor
50
Refrigerant pipe
10
(gas)
73

10

100

24- 3 Holes

Control box

PAC-SA89TA

Return-air
duct flange

262

42

System Control Units

Back View

34
31

22
330
145 144
130 130 35

124
31

89
35

Air outlet guide for PUHZ-P200-250YHA3

200

PAC-SG59SG

PEA-RP250GAQ

A/M-NET adaptor for PUHZ-P200-250YHA3

Front View
124
66

1302
9X130(=1170)
130

7x130(=910)

45

39

33
29

Air Conditioning
1.3.41 1.121

8X130(=1040)

95
250

400
40

1947
1880
1800
1125

340

595

570

Supply air

Drain
Refrigerant pipe

(liquid)

PEA-RP Standard Inverter Heat Pump

22

A
700

40
280
188

395

40

120

39

42.5

50
10

130 130

525

764
664
Return air sensor
(2 places)

40

4- 15

Return air

22.5

130
42.5

10

59

24- 3.1

Fresh-air intake
duct flange

320

20

141

425

Control box
1840

50
10

22
22.5
81

203

10

100

Return-air
duct flange

36- 3 HOLES

Back View

Refrigerant pipe (gas)

130

4X120(=480)
117 156 117

1618
12X130(=1560)

20

1484

Upper View

102

149
29

Supply air

PEA-RP400/500GAQ

Front View
45

40
205

Drain

Refrigerant pipe
(Liquid)

Product Dimensions

565

376

Return air
4- 12

255

1600
1540
1460
1000

11

130

54
10
100 100 25

131
10

40

Fresh-air
intake duct 45
flange

73

20
22- 3.1

40

25

199

1500

634
530
Return air
sensor

262

462

20

Refrigerant pipe
50
(gas)
10
330
22
145 144
130 130 35

100

10

Return air
duct flange

26- 3 Holes

Control box

Note: additional accessories are available, please see the Optional Extras page at
the end of this section for the full range.

Back View

34
66

42

89
35

Remote controller

Upper View

200

PAR-31MAA

1824

1.3.42

PCA-RP
Power Inverter
Heat Pump
(Single Phase)

Our wide range of Power Inverters offer customers high seasonal efficiency, advanced control
options and quiet operation, whilst providing greater flexibility and ease of installation.

Key Features
Indoor unit designed for direct ceiling suspension
Flush to wall installation for concealment of service connections

Ceiling Suspended System


Note: High efficiency filter is optional.

PCA-RP - INDOOR UNITS


CAPACITY (kW)

Heating (nominal)
Cooling (nominal)
Heating (UK)
Cooling (UK)

SHF (nominal & UK)


COP / EER (nominal)
SCOP / SEER (BS EN14825)
ErP ENERgY EFFICIENCY CLASS Heating/Cooling
Lo-Mi1-Mi2-Hi
AIRFLOW (m3/min)
PIPE SIZE mm (in)
Gas/Liquid
SOUND PRESSURE LEvEL (dBA)
Lo-Mi1-Mi2-Hi
SOUND POWER LEvEL (dBA)
DIMENSIONS (mm)
Width x Depth x Height
WEIgHT (kg)
ELECTRICAL SUPPLY
FUSE RATINg (BS88) - HRC (A)
INTERCONNECTINg CABLE No. Cores

PUHZ-ZRP - OUTDOOR UNITS


SOUND PRESSURE LEvEL (dBA) Heating/Cooling
SOUND POWER LEvEL (dBA) Cooling
WEIgHT (kg)
DIMENSIONS (mm) Width x Depth x Height
ELECTRICAL SUPPLY
PHASE
Heating/Cooling (nominal)
SYSTEM POWER
INPUT (kW)
Heating/Cooling (UK)
STARTINg CURRENT (A)
SYSTEM RUNNINg CURRENT (A) Heating/Cooling [MAX]
FUSE RATINg (BS88) - HRC (A)
MAINS CABLE No. Cores
MAX PIPE LENgTH (m)
MAX HEIgHT DIFFERENCE (m)
CHARgE R410A (kg) - 30m

PCA-RP50KAQ

PCA-RP60KAQ

PCA-RP71KAQ

PCA-RP100KAQ

PCA-RP125KAQ

PCA-RP140KAQ

5.5 (2.5-6.6)
5.0 (2.3-5.6)
4.7 (2.15-5.6)
4.6 (2.1-5.15)
0.79
3.79 / 3.73
4.2 / 6.0
A+ / A+
10-11-13-15
12.7 (1/2) / 6.35 (1/4)
32-34-37-40
60
960 x 680 x 230
25
Fed by Outdoor Unit
6
4

7.0 (2.8-8.2)
6.0 (2.7-6.7)
5.95 (2.4-6.95)
5.5 (2.5-6.15)
0.81
3.63 / 3.67
4.3 / 6.2
A+ / A++
15-16-17-19
15.88 (5/8) / 9.52 (3/8)
33-35-37-40
60
1280 x 680 x 230
32
Fed by Outdoor Unit
6
4

8.0 (3.5-10.2)
7.1 (3.3-8.1)
6.8 (3.0-8.65)
6.55 (3.05-7.45)
0.76
3.64 / 3.90
4.3 / 6.6
A+ / A++
16-17-18-20
15.88 (5/8) / 9.52 (3/8)
35-37-39-41
62
1280 x 680 x 230
32
Fed by Outdoor Unit
6
4

11.2 (4.5-14.0)
10.0 (4.9-11.4)
9.5 (3.85-11.9)
9.2 (4.5-10.5)
0.77
3.68 / 3.75
3.9 / 6.0
A / A+
22-24-26-28
15.88 (5/8) / 9.52 (3/8)
37-39-41-43
63
1600 x 680 x 230
36
Fed by Outdoor Unit
6
4

14.0 (5.0-16.0)
12.5 (5.5-14.0)
11.9 (4.25-13.6)
11.5 (5.05-12.9)
0.72
3.68 / 3.14
4.2 / 5.2
N/A
23-25-27-29
15.88 (5/8) / 9.52 (3/8)
39-41-43-45
65
1600 x 680 x 230
38
Fed by Outdoor Unit
6
4

16.0 (5.7-18.0)
13.4 (6.2-15.0)
13.6 (4.85-15.3)
12.9 (5.7-13.8)
0.72
3.50 / 3.39
4.4 / 5.3
N/A
24-26-29-32
15.88 (5/8) / 9.52 (3/8)
41-43-45-48
68
1600 x 680 x 230
39
Fed by Outdoor Unit
6
4

PUHZ-ZRP50VKA

PUHZ-ZRP60VHA

PUHZ-ZRP71VHA

PUHZ-ZRP100VKA

PUHZ-ZRP125VKA

PUHZ-ZRP140VKA

46 / 44
65
46
809 x 300 x 630
220-240v, 50Hz
Single
1.45 / 1.34
1.29 / 1.14
5.0
7.23 / 6.56 [13.4]
16
3
50
30
2.2

48 / 47
67
67
950 x 330 + 30 x 943
220-240v, 50Hz
Single
1.93 / 1.66
1.72 / 1.41
5.0
9.26 / 8.07 [19.4]
25
3
50
30
2.4

48 / 47
67
67
950 x 330 + 30 x 943
220-240v, 50Hz
Single
2.20 / 1.82
1.96 / 1.55
6.0
8.81 / 7.78 [19.4]
25
3
50
30
3.5

51 / 49
69
116
1050 x 330 + 30 x 1338
220-240v, 50Hz
Single
3.04 / 2.67
2.71 / 2.27
12.0
11.61 / 11.29 [27.2]
32
3
75
30
3.5

52 / 50
70
116
1050 x 330 + 30 x 1338
220-240v, 50Hz
Single
3.80 / 3.98
3.38 / 3.38
12.0
16.42 / 17.26 [27.3]
32
3
75
30
5.0

52 / 50
70
119
1050 x 330 + 30 x 1338
220-240v, 50Hz
Single
4.57 / 3.95
4.07 / 3.36
12.0
21.09 / 19.58 [28.9]
40
3
75
30
5.0

Accessories

Product Dimensions

PCA-RP50KAQ

Indoor Units
PAR-SL94B

Front View

Upper View

Wireless remote controller and adaptor

Back View
51

960

10

853

680
476

Air outlet guide for PUHZ-ZRP50vKA

230

Air outlet

254

PAC-SG59SG

195

PAC-SJ07SG

84 88

57

Outdoor Units

184

233

Air outlet guide for PUHZ-ZRP60-71vHA


182

PAC-SH96SG
Air outlet guide for PUHZ-ZRP100-140vKA

(liquid (
(gas (
drain socket (
( When
is installed
(Drainage)

203

246

85

878

Air intake

Product Dimensions

PCA-RP60/71KAQ

System Control Units


PAC-SA89TA

Front View

Upper View

Back View

Remote on/off adaptor

51

PAC-SA88HA

1280

10
5

476
254

Remote sensor

236

230

PAC-SE41TS

195

680

Run/fault adapter

84 88

57

1173

Air outlet

MAC-557IF
182

MELCloud WiFi interface

PAC-SJ19MA

A
B

85

60
179
203

71
180
200

B
233
246

1198

(liquid)
(gas)
drain socket
(When
(
is installed
(Drainage)

Air intake

A/M-NET adaptor for PUHZ-ZRP35-50

PAC-SF83MA
A/M-NET adaptor for PUHZ-ZRP60-140vHA(vKA)

PAR-31MAA
Remote controller

Product Dimensions

PCA-RP100/125/140KAQ

Front View

Upper View

Back View
51
1600
1493

1518

85

10
5

Air outlet

236

680
476
254
182

84 88
195
230

57

180
200
233
246

(liquid)
(gas)

drain socket
(When
(
is installed
(Drainage)

Air intake

Note: additional accessories are available, please see the Optional Extras page at
the end of this section for the full range.

Air Conditioning
1.3.43 1.121

PCA-RP Power Inverter Heat Pump (Single Phase)

1.3.44

PCA-RP
Power Inverter
Heat Pump
(Three Phase)

Our wide range of Power Inverters offer customers high seasonal efficiency, advanced control
options and quiet operation, whilst providing greater flexibility and ease of installation.

Key Features
Indoor unit designed for direct ceiling suspension
Flush to wall installation for concealment of service connections

Ceiling Suspended System


Note: High efficiency filter is optional.

PCA-RP - INDOOR UNITS


CAPACITY (kW)

Heating (nominal)
Cooling (nominal)
Heating (UK)
Cooling (UK)

SHF (nominal & UK)


COP / EER (nominal)
SCOP / SEER (BS EN14825)
ErP ENERgY EFFICIENCY CLASS Heating/Cooling
AIRFLOW (m3/min)
Lo-Mi1-Mi2-Hi
PIPE SIZE mm (in)
Gas/Liquid
SOUND PRESSURE LEvEL (dBA)
Lo-Mi1-Mi2-Hi
SOUND POWER LEvEL (dBA)
DIMENSIONS (mm)
Width x Depth x Height
WEIgHT (kg)
ELECTRICAL SUPPLY
FUSE RATINg (BS88) - HRC (A)
INTERCONNECTINg CABLE No. Cores

PUHZ-ZRP - OUTDOOR UNITS


SOUND PRESSURE LEvEL (dBA) Heating/Cooling
SOUND POWER LEvEL (dBA) Cooling
WEIgHT (kg)
DIMENSIONS (mm) Width x Depth x Height
ELECTRICAL SUPPLY
PHASE
SYSTEM POWER
Heating/Cooling (nominal)
INPUT (kW)
Heating/Cooling (UK)
STARTINg CURRENT (A)
SYSTEM RUNNINg CURRENT (A) Heating/Cooling [MAX]
FUSE RATINg (BS88) - HRC (A)
MAINS CABLE No. Cores
MAX PIPE LENgTH (m)
MAX HEIgHT DIFFERENCE (m)
CHARgE R410A (kg) - 30m

3 Three Phase

PCA-RP100KAQ

PCA-RP125KAQ

PCA-RP140KAQ

11.2 (4.5-14.0)
10.0 (4.9-11.4)
9.5 (3.85-11.9)
9.2 (4.5-10.5)
0.77
3.68 / 3.75
3.9 / 5.9
A / A+
22-24-26-28
15.88 (5/8) / 9.52 (3/8)
37-39-41-43
63
1600 x 680 x 230
36
Fed by Outdoor Unit
6
4

14.0 (5.0-16.0)
12.5 (5.5-14.0)
11.9 (4.25-13.6)
11.5 (5.05-12.9)
0.72
3.68 / 3.14
4.2 / 5.2
N/A
23-25-27-29
15.88 (5/8) / 9.52 (3/8)
39-41-43-45
65
1600 x 680 x 230
38
Fed by Outdoor Unit
6
4

16.0 (5.7-18.0)
13.4 (6.2-15.0)
13.6 (4.85-15.3)
12.3 (5.7-13.8)
0.72
3.50 / 3.39
4.4 / 5.2
N/A
24-26-29-32
15.88 (5/8) / 9.52 (3/8)
41-43-45-48
68
1600 x 680 x 230
39
Fed by Outdoor Unit
6
4

PUHZ-ZRP100YKA
Three Phase

51 / 49
69
124
1050 x 330 + 30 x 1338
380-415v, 50Hz
Three
3.04 / 2.67
2.71 / 2.27
4.0
4.53 / 4.49 [8.7]
16
5
75
30
5.0

PUHZ-ZRP125YKA
Three Phase

52 / 50
70
126
1050 x 330 + 30 x 1338
380-415v, 50Hz
Three
3.80 / 3.98
3.38 / 3.38
4.0
6.30 / 6.60 [10.3]
16
5
75
30
5.0

PUHZ-ZRP140YKA
Three Phase

52 / 50
70
132
1050 x 330 + 30 x 1338
380-415v, 50Hz
Three
4.57 / 3.95
4.07 / 3.36
4.0
8.04 / 7.51 [11.9]
16
5
75
30
5.0

Accessories

Product Dimensions

PCA-RP100/125/140KAQ

Indoor Units
PAR-SL94B

Front View

Upper View

Back View

Wireless remote controller and adaptor


51
2

476
254

Air outlet guide for PUHZ-ZRP100-140YKA


182
1518

System Control Units

85

10
5

Air outlet

236

680

PAC-SH96SG

84 88
195
230

57

Outdoor Units

1600
1493

180
200
233
246

(liquid)
(gas)

drain socket
(When
(
is installed
(Drainage)

Air intake

PAC-SA89TA
Remote on/off adaptor

PAC-SA88HA
Run/fault adapter

PAC-SE41TS
Remote sensor

MAC-557IF
MELCloud WiFi interface

PAC-SF83MA
A/M-NET adaptor for PUHZ-ZRP100-140YKA

PAR-31MAA
Remote controller

Note: additional accessories are available, please see the Optional Extras page at
the end of this section for the full range.

Air Conditioning
1.3.45 1.121

PCA-RP Power Inverter Heat Pump (Three Phase)

1.3.46

PCA-RP
Standard Inverter
Heat Pump
(Single Phase)

Our Standard Inverter range offers customers all the features and benefits of inverter technology
whilst being cost effective.

Key Features
Indoor unit designed for direct ceiling suspension
Flush to wall installation for concealment of service connections

Ceiling Suspended System


Note: High efficiency filter is optional.

PCA-RP - INDOOR UNITS

PCA-RP50KAQ

PCA-RP60KAQ

PCA-RP71KAQ

PCA-RP100KAQ

PCA-RP125KAQ

PCA-RP140KAQ

5.5 (1.7-6.6)
5.0 (2.3-5.6)
4.68 (1.45-5.61)
4.60 (2.12-5.15)
0.79
3.62 / 3.23
4.0 / 5.7
A+ / A+
10-11-13-15
12.7 (1/2) / 6.35 (1/4)
32-34-37-40
60
960 x 680 x 230
25
Fed by Outdoor Unit
6
4

6.9 (2.5-8.0)
5.7 (2.3-6.3)
5.87 (2.13-6.80)
5.24 (2.12-5.80)
0.81
3.61 / 3.31
4.0 / 6.0
A+ / A+
15-16-17-19
15.88 (5/8) / 6.35 (1/4)
33-35-37-40
60
1280 x 680 x 230
32
Fed by Outdoor Unit
6
4

7.9 (2.6-10.2)
7.1 (2.8-8.1)
6.72 (2.21-8.67)
6.53 (2.58-7.45)
0.76
3.62 / 3.41
4.0 / 6.0
A+ / A+
16-17-18-20
15.88 (5/8) / 9.52 (3/8)
35-37-39-41
62
1280 x 680 x 230
32
Fed by Outdoor Unit
6
4

11.2 (4.5-12.5)
9.4 (4.9-11.2)
9.5 (3.85-10.65)
8.65 (4.5-10.3)
0.77
3.41 / 3.00
3.8 / 5.1
A/A
22-24-26-28
15.88 (5/8) / 9.52 (3/8)
37-39-41-43
63
1600 x 680 x 230
36
Fed by Outdoor Unit
6
4

14.0 (5.0-16.0)
12.3 (5.5-14.0)
11.9 (4.25-13.6)
11.3 (5.05-12.9)
0.72
3.40 / 3.01
3.7 / 3.5
N/A
23-25-27-29
15.88 (5/8) / 9.52 (3/8)
39-41-43-45
65
1600 x 680 x 230
38
Fed by Outdoor Unit
6
4

16.0 (5.0-18.0)
13.6 (5.5-15.0)
13.6 (4.25-15.3)
12.5 (5.05-13.8)
0.72
3.41 / 2.81
3.5 / 3.2
N/A
24-26-29-32
15.88 (5/8) / 9.52 (3/8)
41-43-45-48
68
1600 x 680 x 230
39
Fed by Outdoor Unit
6
4

SUZ-KA / PUHZ-P - OUTDOOR UNITS

SUZ-KA50VA4

SUZ-KA60VA4

SUZ-KA71VA4

PUHZ-P100VHA4

PUHZ-P125VHA3

PUHZ-P140VHA3

SOUND PRESSURE LEvEL (dBA) Heating/Cooling


SOUND POWER LEvEL (dBA) Cooling
WEIgHT (kg)
DIMENSIONS (mm) Width x Depth x Height
ELECTRICAL SUPPLY
PHASE
Heating/Cooling (nominal)
SYSTEM POWER
INPUT (kW)
Heating/Cooling (UK)
STARTINg CURRENT (A)
SYSTEM RUNNINg CURRENT (A) Heating/Cooling [MAX]
FUSE RATINg (BS88) - HRC (A)
MAINS CABLE No. Cores
MAX PIPE LENgTH (m)
MAX HEIgHT DIFFERENCE (m)
CHARgE R410A (kg)

52 / 52
65
54
840 x 330 x 880
220-240v, 50Hz
Single
1.52 / 1.55
1.35/ 1.32
7.7
7.50 / 7.70 [12.4]
20
3
30
30
1.45

55 / 55
65
50
840 x 330 x 880
220-240v, 50Hz
Single
1.91 / 1.72
1.70 / 1.46
8.7
7.90 / 8.70 [14.4]
20
3
30
30
1.55

55 / 55
69
53
840 x 330 x 880
220-240v, 50Hz
Single
2.18 / 2.08
1.94 / 1.77
9.1
9.10 / 8.70 [16.5]
20
3
30
30
1.9

54 / 50
70
75
950 x 330 + 30 x 943
220-240v, 50Hz
Single
3.280 / 3.130
2.92 / 2.66
12.0
15.35 / 14.63 [28.7]
32
3
50
30
3.0

55 / 51
71
99
950 x 330 + 30 x 1350
220-240v, 50Hz
Single
4.120 / 4.090
3.67 / 3.48
15.0
17.50 / 18.13 [28.8]
32
3
50
30
4.5

56 / 52
73
99
950 x 330 + 30 x 1350
220-240v, 50Hz
Single
4.690 / 4.840
4.17 / 4.11
15.0
22.21 / 23.38 [30.4]
40
3
50
30
4.5

CAPACITY (kW)

Heating (nominal)
Cooling (nominal)
Heating (UK)
Cooling (UK)

SHF (nominal & UK)


COP / EER (nominal)
SCOP / SEER (BS EN14825)
ErP ENERgY EFFICIENCY CLASS Heating/Cooling
AIRFLOW (m3/min)
Lo-Mi1-Mi2-Hi
PIPE SIZE mm (in)
Gas/Liquid
SOUND PRESSURE LEvEL (dBA)
Lo-Mi1-Mi2-Hi
SOUND POWER LEvEL (dBA)
DIMENSIONS (mm)
Width x Depth x Height (Grille)
WEIgHT (kg)
ELECTRICAL SUPPLY
FUSE RATINg (BS88) - HRC (A)
INTERCONNECTINg CABLE No. Cores

Notes: All units charged to 7m (35-71), 30m (100-140) pipe length. Duty/standby not available on SUZ-KA50/60/71VA4.

Accessories

Product Dimensions

PCA-RP50KAQ

Indoor Units
PAR-SL94B

Front View

Upper View

Wireless remote controller and adaptor

Back View
51

960

10

853

476

680

230

Air outlet

254

Air outlet guide for PUHZ-P100-140vHA3(vHA4)

195

PAC-SG59SG

84 88

57

Outdoor Units

184

(liquid (
(gas (
drain socket (
( When
is installed
(Drainage)

203
233

System Control Units


PAC-SA89TA

182

246

85

878

Air intake

Remote on/off adaptor

PAC-SA88HA

Product Dimensions

PCA-RP60/71KAQ

Run/fault adapter

PAC-SE41TS
Remote sensor

Front View

Upper View

Back View
51

MAC-557IF

1280

10
5

476
254

A/M-NET adaptor for PUHZ-P100-140vHA3(vHA4)

236

230

PAC-SF83MA

195

680

MELCloud WiFi interface

84 88

57

1173

Air outlet

PAR-31MAA
182

Remote controller

A
B

85

60
179
203

71
180
200

B
233
246

1198

(liquid)
(gas)
drain socket
(When
(
is installed
(Drainage)

Air intake

Product Dimensions

PCA-RP100/125/140KAQ

Front View

Upper View

Back View
51
1600
1493

1518

85

10
5

Air outlet

236

680
476
254
182

84 88
195
230

57

180
200
233
246

(liquid)
(gas)

drain socket
(When
(
is installed
(Drainage)

Air intake

Note: additional accessories are available, please see the Optional Extras page at
the end of this section for the full range.

Air Conditioning
1.3.47 1.121

PCA-RP Standard Inverter Heat Pump (Single Phase)

1.3.48

PCA-RP
Standard Inverter
Heat Pump
(Three Phase)

Our Standard Inverter range offers customers all the features and benefits of inverter technology
whilst being cost effective.

Key Features
Indoor unit designed for direct ceiling suspension
Flush to wall installation for concealment of service connections

Ceiling Suspended System


Note: High efficiency filter is optional.

PCA-RP - INDOOR UNITS


CAPACITY (kW)

Heating (nominal)
Cooling (nominal)
Heating (UK)
Cooling (UK)

SHF (nominal & UK)


COP / EER (nominal)
SCOP / SEER (BS EN14825)
ErP ENERgY EFFICIENCY CLASS Heating/Cooling
Lo-Mi1-Mi2-Hi
AIRFLOW (m3/min)
PIPE SIZE mm (in)
Gas/Liquid
SOUND PRESSURE LEvEL (dBA)
Lo-Mi1-Mi2-Hi
SOUND POWER LEvEL (dBA)
DIMENSIONS (mm)
Width x Depth x Height
WEIgHT (kg)
ELECTRICAL SUPPLY
FUSE RATINg (BS88) - HRC (A)
INTERCONNECTINg CABLE No. Cores

PUHZ-P - OUTDOOR UNITS


SOUND PRESSURE LEvEL (dBA) Heating/Cooling
SOUND POWER LEvEL (dBA) Cooling
WEIgHT (kg)
DIMENSIONS (mm) Width x Depth x Height
ELECTRICAL SUPPLY
PHASE
Heating/Cooling (nominal)
SYSTEM POWER
INPUT (kW)
Heating/Cooling (UK)
STARTINg CURRENT (A)
SYSTEM RUNNINg CURRENT (A) Heating/Cooling [MAX]
FUSE RATINg (BS88) - HRC (A)
MAINS CABLE No. Cores
MAX PIPE LENgTH (m)
MAX HEIgHT DIFFERENCE (m)
CHARgE R410A (kg)

3 Three Phase

PCA-RP100KAQ

PCA-RP125KAQ

PCA-RP140KAQ

11.2 (4.5-12.5)
9.4 (4.9-11.2)
9.5 (3.85-10.65)
8.65 (4.5-10.3)
0.77
3.41 / 3.00
3.8 / 5.1
A/A
22-24-26-28
15.88 (5/8) / 9.52 (3/8)
37-39-41-43
63
1600 x 680 x 230
36
Fed by Outdoor Unit
6
4

14.0 (5.0-16.0)
12.3 (5.5-14.0)
11.9 (4.25-13.6)
11.3 (5.05-12.9)
0.72
3.40 / 3.01
3.7 / 3.5
N/A
23-25-27-29
15.88 (5/8) / 9.52 (3/8)
39-41-43-45
65
1600 x 680 x 230
38
Fed by Outdoor Unit
6
4

16.0 (5.0-18.0)
13.6 (5.5-15.0)
13.6 (4.25-15.3)
12.5 (5.05-13.8)
0.72
3.41 / 2.81
3.5 / 3.2
N/A
24-26-29-32
15.88 (5/8) / 9.52 (3/8)
41-43-45-48
68
1600 x 680 x 230
39
Fed by Outdoor Unit
6
4

PUHZ-P100YHA2
Three Phase

54 / 50
70
77
950 x 330 + 30 x 943
380-415v, 50Hz
Three
3.280 / 3.130
2.92 / 2.66
4.0
5.91 / 5.65 [13.7]
16
5
50
30
3.0

Notes: All units charged to 7m (35-71), 30m (100-140) pipe length.

PUHZ-P125YHA
Three Phase

55 / 51
71
101
950 x 330 + 30 x 1350
380-415v, 50Hz
Three
4.120 / 4.090
3.67 / 3.48
5.0
6.85 / 6.94 [13.8]
16
5
50
30
4.5

PUHZ-P140YHA
Three Phase

56 / 52
73
101
950 x 330 + 30 x 1350
380-415v, 50Hz
Three
4.690 / 4.840
4.17 / 4.11
5.0
8.48 / 8.82 [13.9]
16
5
50
30
4.5

Accessories

Product Dimensions

PCA-RP100/125/140KAQ

Indoor Units
PAR-SL94B

Front View

Upper View

Back View

Wireless remote controller and adaptor


51
1600
1493

476
254

PAC-SG59SG
Air outlet guide for PUHZ-P100-140YHA2(YHA)

182
1518

85

10
5

Air outlet

236

680

Outdoor Units

84 88
195
230

57

180
200
233
246

(liquid)
(gas)

drain socket
(When
(
is installed
(Drainage)

Air intake

System Control Units


PAC-SA89TA
Remote on/off adaptor

PAC-SA88HA
Run/fault adapter

PAC-SE41TS
Remote sensor

MAC-557IF
MELCloud WiFi interface

PAC-SF83MA
A/M-NET adaptor for PUHZ-P100-140YHA2(YHA)

PAR-31MAA
Remote controller

Note: additional accessories are available, please see the Optional Extras page at
the end of this section for the full range.

Air Conditioning
1.3.49 1.121

PCA-RP Standard Inverter Heat Pump (Three Phase)

1.3.50

PCA-RP-HAQ
Power Inverter
Heat Pump
Stainless Steel Ceiling
Suspended System

Our Power Inverter Heat Pump offers customers high seasonal efficiency, advanced control options
and quiet operation, whilst providing greater flexibility and ease of installation. The PCA-RP-HAQ series
is a ceiling suspended unit ideal for use in kitchen environments. The external casing is made of durable
stainless steel that is resistant to oil and smoke, ensuring that the unit can be easily cleaned at all times.

Key Features
High performance oil mist filter
Easy maintenance - fan casing can be separated into different sections allowing easy cleaning.
The drain pan can also be cleaned easily on-site as the pipe connector can be quickly removed
Optional decoration covers

PCA-RP-HAQ - INDOOR UNITS


CAPACITY (kW)

Heating (nominal)
Cooling (nominal)
Heating (UK)
Cooling (UK)

SHF (nominal & UK)


COP / EER (nominal)
SCOP / SEER
ENERgY EFFICIENCY CLASS
Heating/Cooling
Lo-Hi
AIRFLOW (m3/min)
PIPE SIZE mm (in)
Gas/Liquid
SOUND PRESSURE LEvEL (dBA)
Lo-Hi
SOUND POWER LEvEL (dBA)
DIMENSIONS (mm)
Width x Depth x Height
WEIgHT (kg)
ELECTRICAL SUPPLY
FUSE RATINg (BS88) - HRC (A)
INTERCONNECTINg CABLE No. Cores

PUHZ-ZRP - OUTDOOR UNITS


SOUND PRESSURE LEvEL (dBA) Heating/Cooling
SOUND POWER LEvEL (dBA) Cooling
WEIgHT (kg)
DIMENSIONS (mm) Width x Depth x Height
ELECTRICAL SUPPLY
PHASE
SYSTEM POWER
Heating/Cooling (nominal)
INPUT (kW)
Heating/Cooling (UK)
STARTINg CURRENT (A)
SYSTEM RUNNINg CURRENT (A) Heating/Cooling [MAX]
FUSE RATINg (BS88) - HRC (A)
MAINS CABLE No. Cores
MAX PIPE LENgTH (m)
MAX HEIgHT DIFFERENCE (m)
CHARgE R410A (kg) - 30m

PCA-RP71HAQ
7.6 (3.5-10.2)
7.1 (3.3-8.1)
6.45 (3.0-8.65)
6.55 (3.05-7.45)
0.74
3.23 / 3.27
3.8 / 5.6
A / A+
17-19
15.88 (5/8) / 9.52 (3/8)
34-38
56
1136 x 650 x 280
41
Fed by Outdoor Unit
6
4

PUHZ-ZRP71VHA
48 / 47
67
67
950 x 330 + 30 x 943
220-240v, 50Hz
Single
2.35 / 2.17
2.09 / 1.84
6.0
8.82 / 7.79 [19.4]
25
3
50
30
3.5

Accessories

Product Dimensions

PCA-RP71HAQ

Indoor Units
PAR-SL94B

Upper View

<liquid>
175

130

15

Decoration covers (front cover & suspending


bracket) for PCA-RP71HAQ

197

PAC-SF81KC

Terminal block box


Electrical box

21

Oil mist filter for PCA-RP71HAQ (12 pack)

110

PAC-SG38KF

<gas>

Wireless remote controller and adaptor

Outdoor Units
PAC-SG59SG
Air outlet guide for PUHZ-ZRP71vHA

System Control Units


PAC-SA89TA
Remote on/off adaptor

PAC-SA88HA
Run/fault adapter

Front View

Side View

A/M-NET adaptor for PUHZ-ZRP71vHA

1224
1180

Suspension bolt

<Suspension bolt pitch>

495

75

320

80

<Suspension bolt pitch>


43
243

75
280

110

102

Remote controller

<Air outlet>

PAR-31MAA

70
986 <Air

outlet>

75

289

1136

650

Inspection port
(pipe sensor)

<Flexible hose(accessory)>

Note: additional accessories are available, please see the Optional Extras page at
the end of this section for the full range.

Air Conditioning
1.3.51 1.121

254
295

PAC-SF83MA

70~90

Remote sensor

13

PAC-SE41TS

PCA-RP-HAQ Power Inverter Heat Pump

1.3.52

PSA-RP
Power Inverter
Heat Pump

Our wide range of Power Inverters offer customers high seasonal efficiency, advanced control
options and quiet operation, whilst providing greater flexibility and ease of installation.

Key Features
Built in controller

Floor Standing System


Note: When used with a Mr Slim Multi-Split system PSA-RP cannot be connected with indoor units of different type.

PSA-RP - INDOOR UNITS

PSA-RP71KA

PSA-RP100KA

PSA-RP100KA

PSA-RP125KA

PSA-RP125KA

PSA-RP140KA

PSA-RP140KA

11.2 (4.5-14.0)
14.0 (5.0-16.0)
16.0 (5.7-18.0)
7.6 (3.5-10.2)
11.2 (4.5-14.0)
14.0 (5.0-16.0)
16.0 (5.7-18.0)
10.0 (4.9-11.4)
12.5 (5.5-14.0)
13.4 (6.2-15.0)
7.1 (3.3-8.1)
10.0 (4.9-11.4)
12.5 (5.5-14.0)
13.4 (6.2-15.0)
9.5 (3.85-11.9)
11.9 (4.25-13.6)
13.6 (4.84-15.3)
6.45 (3.0-8.65)
9.5 (3.85-11.9)
11.9 (4.25-13.6)
13.6 (4.84-15.3)
9.2 (4.5-10.5)
11.4 (5.05-12.9)
12.3 (5.7-13.8)
6.55 (3.05-7.45)
9.2 (4.5-10.5)
11.4 (5.05-12.9)
12.3 (5.7-13.8)
0.73
0.72
0.71
0.75
SHF (nominal & UK)
0.73
0.72
0.71
3.64 / 3.64
3.30 / 3.06
3.34 / 3.30
3.44 / 3.76
COP / EER (nominal)
3.64 / 3.64
3.30 / 3.06
3.34 / 3.30
4.0 / 5.6
4.0 / 5.0
4.4 / 5.3
4.0 / 6.3
SCOP / SEER (BS EN14825)
4.0 / 5.5
4.0 / 4.9
4.4 / 5.3
A+ / A+
N/A
N/A
A+ / A++
ErP ENERgY EFFICIENCY CLASS Heating/Cooling
A+ / A
N/A
N/A
3
25-28-30
25-28-31
25-28-31
20-22-24
AIRFLOW (m /min)
Lo-Mi-Hi
25-28-30
25-28-31
25-28-31
15.88 (5/8) / 9.52 (3/8) 15.88 (5/8) / 9.52 (3/8) 15.88 (5/8) / 9.52 (3/8) 15.88 (5/8) / 9.52 (3/8) 15.88 (5/8) / 9.52 (3/8) 15.88 (5/8) / 9.52 (3/8) 15.88 (5/8) / 9.52 (3/8)
PIPE SIZE mm (in)
Gas/Liquid
45-49-51
40-42-44
45-49-51
45-49-51
SOUND PRESSURE LEvEL (dBA)
Lo-Mi-Hi
45-49-51
45-49-51
45-49-51
66
60
65
66
SOUND POWER LEvEL (dBA)
66
66
65
600 x 360 x 1900
600 x 360 x 1900
600 x 360 x 1900
600 x 360 x 1900
DIMENSIONS (mm)
Width x Depth x Height (Grille)
600 x 360 x 1900
600 x 360 x 1900
600 x 360 x 1900
48
46
46
46
WEIgHT (kg)
Unit / Panel
46
48
46
Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit
ELECTRICAL SUPPLY
6
6
6
6
FUSE RATINg (BS88) - HRC (A)
6
6
6
4
4
4
4
INTERCONNECTINg CABLE No. Cores
4
4
4
CAPACITY (kW)

Heating (nominal)
Cooling (nominal)
Heating (UK)
Cooling (UK)

PUHZ-ZRP - OUTDOOR UNITS


SOUND PRESSURE LEvEL (dBA) Heating/Cooling
SOUND POWER LEvEL (dBA) Cooling
WEIgHT (kg)
DIMENSIONS (mm) Width x Depth x Height
ELECTRICAL SUPPLY
PHASE
Heating/Cooling (nominal)
SYSTEM POWER
INPUT (kW)
Heating/Cooling (UK)
STARTINg CURRENT (A)
SYSTEM RUNNINg CURRENT (A) Heating/Cooling [MAX]
FUSE RATINg (BS88) - HRC (A)
MAINS CABLE No. Cores
MAX PIPE LENgTH (m)
MAX HEIgHT DIFFERENCE (m)
CHARgE R410A (kg) - 30m

3 Three Phase

PUHZ-ZRP71VHA

PUHZ-ZRP100VKA PUHZ-ZRP100YKA
PUHZ-ZRP125VKA PUHZ-ZRP125YKA
PUHZ-ZRP140VKA PUHZ-ZRP140YKA
Three Phase
Three Phase
Three Phase
3
3
3

52 / 50
52 / 50
48 / 47
51 / 49
52 / 50
52 / 50
51 / 49
70
70
67
69
70
70
69
119
132
67
124
116
126
116
950 x 330 + 30 x 943 1050 x 330 + 30 x 1338 1050 x 330 + 30 x 1338 1050 x 330 + 30 x 1338 1050 x 330 + 30 x 1338 1050 x 330 + 30 x 1338 1050 x 330 + 30 x 1338
380-415v, 50Hz
220-240v, 50Hz
220-240v, 50Hz
380-415v, 50Hz
220-240v, 50Hz
380-415v, 50Hz
220-240v, 50Hz
Three
Single
Single
Three
Single
Three
Single
3.08 / 2.75
4.24 / 4.09
3.08 / 2.75
4.24 / 4.09
4.79 / 4.06
4.79 / 4.06
2.21 / 1.89
2.74 / 2.34
3.77 / 3.48
2.74 / 2.34
3.77 / 3.48
4.26 / 3.45
4.26 / 3.45
1.97 / 1.61
4.0
12.0
12.0
4.0
12.0
4.0
6.0
4.54 / 4.55 [8.7]
16.39 / 17.23 [27.2]
11.58 / 11.62 [27.2]
6.27 / 6.57 [10.2]
20.92 / 19.41 [28.7]
7.87 / 7.34 [11.7]
8.79 / 7.76 [19.4]
16
32
32
16
40
16
25
5
3
3
5
3
3
3
75
75
75
75
75
75
50
30
30
30
30
30
30
30
5.0
5.0
5.0
5.0
5.0
5.0
3.5

Accessories

Product Dimensions

PSA-RP71/100/125/140KA

Outdoor Units
PAC-SG59SG
Air outlet guide for PUHZ-ZRP71vHA

Upper View

Front View

Side View

PAC-SH96SG

Run/fault adapter

40

40
20

360

260

10

132

140

Remote on/off adaptor

PAC-SA88HA

Metal fixture
against overturning

520
260
240

125
340
370

Controller

130

PAC-SA89TA

Knockout hole
for branch duct
10

100
130

System Control Units

240

111
38 15

38
10

Air outlet guide for PUHZ-ZRP100-140vKA(YKA)

PAC-SE41TS
Remote sensor

71
820

129

MAC-557IF

1900

MELCloud WiFi interface

PAC-SF83MA
A/M-NET adaptor for PUHZ-ZRP71-140vHA(vKA/YKA)

PAR-31MAA

115

181

50

834

599

Remote controller

30

70
524
600

260
310
Knockout hole for refrigerant and drainage
9060 oval (Provided on both sides)

Note: additional accessories are available, please see the Optional Extras page at
the end of this section for the full range.

Air Conditioning
1.3.53 1.121

PSA-RP Power Inverter Heat Pump

Knockout hole for wiring 27


(Provided on both sides)

1.3.54

PSA-RP
Standard Inverter
Heat Pump
Floor Standing System

Our Standard Inverter range offers customers all the features and benefits of inverter technology
whilst being cost effective. The PSA-RP Floor Standing System complements the Mitsubishi Electric
range of indoor units. The sleek, modern design of this unit is ideal for numerous applications
including bars and restaurants.

Key Features
Built in controller
Note: When used with a Mr Slim Multi-Split system PSA-RP cannot be connected with indoor units of different type.

PSA-RP - INDOOR UNITS


CAPACITY (kW)

Heating (nominal)
Cooling (nominal)
Heating (UK)
Cooling (UK)

SHF (nominal & UK)


COP / EER (nominal)
SCOP / SEER (BS EN14825)
ErP ENERgY EFFICIENCY CLASS Heating/Cooling
AIRFLOW (m3/min)
Lo-Mi-Hi
PIPE SIZE mm (in)
Gas/Liquid
SOUND PRESSURE LEvEL (dBA)
Lo-Mi-Hi
SOUND POWER LEvEL (dBA)
DIMENSIONS (mm)
Width x Depth x Height (Grille)
WEIgHT (kg)
ELECTRICAL SUPPLY
FUSE RATINg (BS88) - HRC (A)
INTERCONNECTINg CABLE No. Cores

PUHZ-P - OUTDOOR UNITS


SOUND PRESSURE LEvEL (dBA) Heating/Cooling
SOUND POWER LEvEL (dBA) Cooling
WEIgHT (kg)
DIMENSIONS (mm) Width x Depth x Height
ELECTRICAL SUPPLY
PHASE
Heating/Cooling (nominal)
SYSTEM POWER
INPUT (kW)
Heating/Cooling (UK)
STARTINg CURRENT (A)
SYSTEM RUNNINg CURRENT (A) Heating/Cooling [MAX]
FUSE RATINg (BS88) - HRC (A)
MAINS CABLE No. Cores
MAX PIPE LENgTH (m)
MAX HEIgHT DIFFERENCE (m)
CHARgE R410A (kg)

3 Three Phase

PSA-RP100KA

PSA-RP100KA

PSA-RP125KA

PSA-RP125KA

PSA-RP140KA

PSA-RP140KA

11.2 (4.5-12.5)
9.4 (4.9-11.2)
9.5 (3.85-10.65)
8.65 (4.5-10.3)
0.73
3.41 / 3.01
3.8 / 4.6
A/B
25-28-30
15.88 (5/8) / 9.52 (3/8)
45-49-51
65
600 x 360 x 1900
46
Fed by Outdoor Unit
6
4

11.2 (4.5-12.5)
9.4 (4.9-11.2)
9.5 (3.85-10.65)
8.65 (4.5-10.3)
0.73
3.41 / 3.01
3.8 / 4.6
A/B
25-28-30
15.88 (5/8) / 9.52 (3/8)
45-49-51
65
600 x 360 x 1900
46
Fed by Outdoor Unit
6
4

14.0 (5.0-16.0)
12.3 (5.5-14.0)
11.9 (4.25-13.6)
11.3 (5.05-12.9)
0.72
2.81 / 2.81
3.7 / 3.5
N/A
25-28-31
15.88 (5/8) / 9.52 (3/8)
45-49-51
66
600 x 360 x 1900
46
Fed by Outdoor Unit
6
4

14.0 (5.0-16.0)
12.3 (5.5-14.0)
11.9 (4.25-13.6)
11.3 (5.05-12.9)
0.72
2.81 / 2.81
3.7 / 3.5
N/A
25-28-31
15.88 (5/8) / 9.52 (3/8)
45-49-51
66
600 x 360 x 1900
46
Fed by Outdoor Unit
6
4

16.0 (5.0-18.0)
13.6 (5.5-15.0)
13.6 (4.25-15.3)
12.5 (5.06-12.7)
0.71
2.81 / 2.41
3.4 / 3.2
N/A
25-28-31
15.88 (5/8) / 9.52 (3/8)
45-49-51
66
600 x 360 x 1900
48
Fed by Outdoor Unit
6
4

16.0 (5.0-18.0)
13.6 (5.5-15.0)
13.6 (4.25-15.3)
12.5 (5.06-12.7)
0.71
2.81 / 2.41
3.4 / 3.2
N/A
25-28-31
15.88 (5/8) / 9.52 (3/8)
45-49-51
66
600 x 360 x 1900
48
Fed by Outdoor Unit
6
4

PUHZ-P100VHA4
54 / 50
70
75
950 x 330 + 30 x 943
220-240v, 50Hz
Single
3.280 / 3.120
2.92 / 2.65
12.0
15.36 / 14.69 [28.7]
32
3
50
30
3.0

Notes: All units charged to 30m (100-140) pipe length.

PUHZ-P100YHA2 3
Three Phase

PUHZ-P125VHA3

54 / 50
70
77
950 x 330 + 30 x 943
380-415v, 50Hz
Three
3.280 / 3.120
2.92 / 2.65
4.0
5.92 / 5.71 [13.7]
16
5
50
30
3.0

55 / 51
71
99
950 x 330 + 30 x 1350
220-240v, 50Hz
Single
4.980 / 4.380
4.43 / 3.72
15.0
17.47 / 18.10 [28.7]
32
3
50
30
4.5

PUHZ-P125YHA 3
Three Phase

PUHZ-P140VHA3

55 / 51
71
101
950 x 330 + 30 x 1350
380-415v, 50Hz
Three
4.980 / 4.380
4.43 / 3.72
5.0
6.82 / 6.91 [13.7]
16
5
50
30
4.5

56 / 52
73
99
950 x 330 + 30 x 1350
220-240v, 50Hz
Single
5.690 / 5.640
5.06 / 4.79
15.0
22.04 / 23.21 [30.2]
40
3
50
30
4.5

PUHZ-P140YHA 3
Three Phase

56 / 52
73
101
950 x 330 + 30 x 1350
380-415v, 50Hz
Three
5.690 / 5.640
5.06 / 4.79
5.0
8.31 / 8.65 [13.7]
16
3
50
30
4.5

Accessories

Product Dimensions

PSA-RP100/125/140KA

Outdoor Units
PAC-SG59SG
Front View

MAC-557IF

40
20

360

260
140

Remote sensor

100
130

Run/fault adapter

PAC-SE41TS

Metal fixture
against overturning

520
260
240

125
340
370

Controller

MELCloud WiFi interface

130

PAC-SA88HA

Knockout hole
for branch duct
10
132

Remote on/off adaptor

240

111
38 15

PAC-SA89TA

38
10

System Control Units

Side View

40

Upper View

10

Air outlet guide for


PUHZ-P100-140vHA4(YHA2/vHA3/YHA)

71
820

129

PAC-SF83MA

1900

A/M-NET adaptor for


PUHZ-P100-140vHA4(YHA2/vHA3/YHA)

PAR-31MAA

115

181

50

834

599

Remote controller

30

70
524
600

260
310
Knockout hole for refrigerant and drainage
9060 oval (Provided on both sides)

Note: additional accessories are available, please see the Optional Extras page at
the end of this section for the full range.

Air Conditioning
1.3.55 1.121

PSA-RP Standard Inverter Heat Pump

Knockout hole for wiring 27


(Provided on both sides)

1.3.56

HP DXE
Heat Pump Air Curtain

In collaboration with Thermoscreens, Mitsubishi Electric have developed a new range of air curtains
that can be connected to our Power Inverter heat pumps, as opposed to the more traditional direct
electric method associated with air curtains.

Key Features

Reduced CO2 emissions and run costs (up to 67%)


2.5 year payback period against equivalent electric systems
Inverter technology (does not waste energy)
Range of different sizes to suit every application
Allows open door policy in retail outlets whilst being energy efficient

HP DXE - RECESSED
Heating (nominal)
Cooling (nominal)
AIR vOLUME MAX (m3/h)
SOUND PRESSURE LEvEL AT 3m (dBA) Lo-Mi1-Hi
WEIgHT (kg)
DIMENSIONS (mm) Width x Depth x Height
ELECTRICAL SUPPLY*1
PHASE*1
RUNNINg CURRENT (A)*1
MAINS CABLE No. Cores*1
UNIFORMITY AT OUTLET (%)*2
MAX MOUNTINg HEIgHT (m)
CAPACITY (kW)

HP DXE - FREE STANDING


Heating (nominal)
Cooling (nominal)
3
AIR vOLUME MAX (m /h)
SOUND PRESSURE LEvEL AT 3m (dBA) Lo-Mi1-Hi
WEIgHT (kg)
DIMENSIONS (mm) Width x Depth x Height
ELECTRICAL SUPPLY*1
PHASE*1
RUNNINg CURRENT (A)*1
MAINS CABLE No. Cores*1
UNIFORMITY AT OUTLET (%)*2
MAX MOUNTINg HEIgHT (m)
CAPACITY (kW)

HEAT PUMP OUTDOOR UNITS


SOUND PRESSURE LEvEL (dBA) Heating/Cooling
SOUND POWER LEvEL (dBA) Cooling
WEIgHT (kg)
DIMENSIONS (mm) Width x Depth x Height
ELECTRICAL SUPPLY
PHASE
STARTINg CURRENT (A)
FUSE RATINg (BS88) - HRC (A)
INTERCONNECTINg CABLE
MAX PIPE LENgTH (m)
MAX HEIgHT DIFFERENCE (m)
CHARgE R410A (kg) - 30m

3 Three Phase

Clean environment - protection from dust, fumes etc


Comfortable climate for customers
Easy to install and maintain
New centrifugal fan
New weather compensation option for further
energy efficiency

HP1000R DXE

HP1500R DXE

HP1500R DXE

HP2000R DXE

HP2000R DXE

HP2000R DXE

8.3
7.4
1310
50-55-58
52
1250 x 348 x 539
220-240v, 50Hz
Single
0.8
3
90
3.3

13.8
12.3
2070
49-54-58
75
1750 x 348 x 539
220-240v, 50Hz
Single
1.2
3
92
3.3

13.8
12.3
2070
49-54-58
75
1750 x 348 x 539
220-240v, 50Hz
Single
1.2
3
92
3.3

15.9
14.2
2590
50-55-58
93
2340 x 348 x 539
220-240v, 50Hz
Single
1.4
3
90
3.3

15.9
14.2
2590
50-55-58
93
2340 x 348 x 539
220-240v, 50Hz
Single
1.4
3
90
3.3

21.0
18.7
2590
50-55-58
93
2340 x 348 x 539
220-240v, 50Hz
Single
1.4
3
90
3.3

HP1000 DXE

HP1500 DXE

HP1500 DXE

HP2000 DXE

HP2000 DXE

HP2000 DXE

8.3
7.4
1310
50-55-58
46
1300 x 468 x 306
220-240v, 50Hz
Single
0.8
3
90
3.3

13.2
11.8
2070
49-54-58
67
1825 x 468 x 306
220-240v, 50Hz
Single
1.2
3
92
3.3

13.2
11.8
2070
49-54-58
67
1825 x 468 x 306
220-240v, 50Hz
Single
1.2
3
92
3.3

15.7
14.0
2590
50-55-58
84
2350 x 468 x 306
220-240v, 50Hz
Single
1.4
3
90
3.3

15.7
14.0
2590
50-55-58
84
2350 x 468 x 306
220-240v, 50Hz
Single
1.4
3
90
3.3

21.0
18.7
2590
50-55-58
93
2350 x 468 x 306
220-240v, 50Hz
Single
1.4
3
90
3.3

PUHZ-ZRP71VHA

PUHZ-ZRP125VKA

48 / 47
67
67
950 x 330 +30 x 943
220-240v, 50Hz
Single
5
25
2 Core
50
30
3.5

52 / 50
70
116
1050 x 330 +30 x 1338
220-240v, 50Hz
Single
5
32
2 Core
75
30
5.0

PUHZ-ZRP125YKA 3
Three Phase

52 / 50
70
126
1050 x 330 +30 x 1338
380-415v, 50Hz
Three
5
16
2 Core
75
30
5.0

PUHZ-ZRP140VKA
52 / 50
70
119
1050 x 330 +30 x 1338
220-240v, 50Hz
Single
5
40
2 Core
75
30
5.0

PUHZ-ZRP140YKA 3
Three Phase

52 / 50
70
132
1050 x 330 +30 x 1338
380-415v, 50Hz
Three
5
16
2 Core
75
30
5.0

Notes: *1 For indoor units with electric heaters enabled, 380-415V 3ph power supply (7.3A HP1000, 12.1A HP1500, 14.4A HP2000). *2 Tested to ISO 27327.

PUHZ-RP200YKA 3
Three Phase

59 / 58
135
1050 x 330 +30 x 1338
380-415v, 50Hz
Three
5
20
2 Core
100
30
5.0

Accessories
Outdoor Units

Product Dimensions

HP1000/1500/2000R DX-E

Front View

Upper View

Side View

Upper View

Side View

PAC-SG59SG
Air outlet guide for PUHZ-ZRP71vHA

PAC-SH96SG
Air outlet guide for PUHZ-ZRP125-140vKA(YKA)

System Control Units


PAC-SF83MA
A/M-NET adaptor for PUHZ-ZRP71-140vHA(vKA/YKA)

PAR-31MAA
Remote controller

PAR-W21MAA
Remote controller

Product Dimensions
Front View

HP1000/1500/2000 DX-E

Note: additional accessories are available, please see the Optional Extras page at
the end of this section for the full range.

Air Conditioning
1.3.57 1.121

Heat Pump Air Curtain

1.3.58

PAC-IF012B-E
Air Handling Unit Controller

The Air Handling Unit Controllers are an interface to allow connection to third party manufacturer
equipment. Mitsubishi Electric Mr Slim outdoor units can be used with this interface box, creating
an ideal solution when a unique air handling unit is required.

Key Features

No need for expansion device


Error, operation and defrost output
Demand control by analogue or digital inputs (0-10, 4-20mA, 1-5V, 0-10V, step, auto-step)
Includes a third thermistor to enable auto-step
Lossnay Kanzen Packaged Air Handling Unit also available, please refer to the Ventilation section
for further information

PAC-IF012B-E
CAPACITY (kW)
AUTO STEP

MANUAL STEP

PIPE SIZE mm (in)

HEAT EXCHANgER
DIMENSIONS (mm)
WEIgHT (kg)

Heating (nominal)
Cooling (nominal)
PUHZ-ZRP
PUHZ-RP
PUHZ-P
SUZ-KA
PUHZ-SHW
PUHZ-ZRP
PUHZ-RP
PUHZ-SHW
PUHZ-(Z/R)P/SHW Gas
Liquid
SUZ-KA
Gas
Liquid
Max Capacity
Min Capacity
Width x Depth x Height

SIZE 35

SIZE 50

SIZE 60

SIZE 71

SIZE 100

SIZE 125

SIZE 140

SIZE 200

SIZE 250

4.1
3.6
vKA
vA4
vKA
12.7 (1/2)
6.35 (1/4)
9.52 (3/8)
6.35 (1/4)
1050
350

6.0
5.0
vKA
vA4
vKA
12.7 (1/2)
6.35 (1/4)
12.7 (1/2)
6.35 (1/4)
1500
500

7.0
6.0
vKA
vA4
vKA
15.88 (5/8)
9.52 (3/8)
15.88 (5/8)
6.35 (1/4)
1800
600

8.0
7.1
vKA
vA4
vHA
vKA
vHA
15.88 (5/8)
9.52 (3/8)
15.88 (5/8)
9.52 (3/8)
2130
710

11.2
10.0
vKA/YKA
vHA4/YHA2
vHA/YHA
vKA/YKA
vHA/YHA
15.88 (5/8)
9.52 (3/8)
-

14.0
12.5
vKA/YKA
vHA3/YHA
YHA
vKA/YKA
YHA
15.88 (5/8)
9.52 (3/8)
-

16.0
14.0
vKA/YKA
vHA3/YHA
vKA/YKA
15.88 (5/8)
9.52 (3/8)
-

22.4
19.0
YKA
YHA3
YKA
28.58 (1 1/8)
9.52 (3/8)
-

27.0
22.0
YKA
YHA3
YKA
28.58 (1 1/8)
12.7 (1/2)
-

3000
1000

3750
1250

4200
1400

6000
2000

7500
2500

336 x 69 x 278
2.5

336 x 69 x 278
2.5

336 x 69 x 278
2.5

336 x 69 x 278
2.5

336 x 69 x 278
2.5

336 x 69 x 278
2.5

336 x 69 x 278
2.5

336 x 69 x 278
2.5

336 x 69 x 278
2.5

Notes: One air handling unit controller is required per air handling unit.
Cooling: Indoor 27C DB/19C WB, Outdoor 35C DB/24C WB.
Heating: Indoor 20C DB, Outdoor 7C DB/6C WB.

Example:

Air Handling Unit Controller


(Mitsubishi Electric)

A Control wiring

Controller (field supplied)

Thermistor wiring

Piping
Outdoor Unit (Mitsubishi Electric)

Air Handling Unit (field supplied)

Accessories

Product Dimensions

PAC-IF012B-E

System Control Units


PAR-31MAA

Upper View

Remote controller

Front View

Side View
336
313

69

5
12

22

(11.5)

T B61

10

11. 5

200

T B62
T B1 42

T B1 41

278

2-HOLES
(FOR
INSTALLATION)

T B6

2-5 HOLES
(FOR
INSTALLATION)

3- ELECTRIC WIRE INLET

Note: additional accessories are available, please see the Optional Extras page at
the end of this section for the full range.

Air Conditioning
1.3.59 1.121

Air Handling Unit Controller

1.3.60

Mr Slim Twin /
Triple / Quad
Combinations
Inverter Heat Pump Units

The Mr Slim Multi-Split system is an ideal option for open plan spaces in medium sized premises such as
offices or shops, where two, three or four units are required. These can be Mr Slim ceiling cassettes (PLA-(Z)RP
& SLZ-KA), ceiling suspended (PCA-RP), ducted (PEAD-RP), floor standing (PSA-RP) or wall mounted (PKA-RP)
models and can be connected to a single outdoor unit using twin, triple or quadruple multi distributor pipes.

Key Features
Twin, triple or quadruple indoor heat pump units can be operated in Multi-Split configuration from a single outdoor unit
Heat pumps must operate in same heating or cooling mode
Cooling capacity range 7.1 to 28kW
Heating capacity range 8.0 to 31.5kW
SLZ-KA indoor units can now be connected as part of a Mr Slim Multi-Split system

PIPE RUN PARAMETERS


PIPE RUNS

MAX. PIPE RUN (M)

PUHZ-P100-140VHA3/VHA4/YHA/YHA2

OUTDOOR MODEL

A+B+C twin

50

PUHZ-P200/250YHA3

A+B+C twin

70

PUHZ-ZRP71VHA

A+B+C twin

50

PUHZ-ZRP100-140VKA/YKA

A+B+C twin

75

PUHZ-RP200/250YKA

A+B+C twin

80 (120)

PUHZ-SHW80-140VHA/YHA

A+B+C twin

75

PUHZ-P140VHA3/YHA

A+B+C+D triple

50

PUHZ-P200/250YHA3

A+B+C+D triple

70

PUHZ-ZRP140VKA/YKA

A+B+C+D triple

75

PUHZ-RP200/250YKA

A+B+C+D triple

80 (120)

PUHZ-P200/250YHA3

A+B+C+D+E quadruple

70

PUHZ-RP200/250YKA

A+B+C+D+E quadruple

80 (120)

PUHZ-P100-140VHA3/VHA4/YHA/YHA2

B C or C D or B D

PUHZ-ZRP71-140VHA/VKA/YKA

B C or C D or B D

8
8
8
8
8

PUHZ-SHW80-140VHA/YHA

B-C

PUHZ-P200/250YHA3

B - C or B - D or B - E or C - D or C - E or D - E

PUHZ-RP200/250YKA
H = 30m.

h = 1m.

B - C or B - D or B - E or C - D or C - E or D - E
Note: H for the PUHZ-RP200/250YKA = 40m

TWIN
Indoor Units

Indoor
Units

PSA-RP indoor units cannot be connected with indoor units of


different type.

PKA-RP indoor units cannot be connected to PUHZ-SHW80 &


PUHZ-SHW140 outdoor units.

Notes: SEZ-KD indoor units cannot be used as part of a Mr Slim Multi-Split system.

PCA-RP, PSA-RP and SLZ-KA indoor units cannot be connected to


PUHZ-SHW outdoor units.

Outdoor Units

D
h

Indoor Units
B
h
C

Multi distributor
Pipes

Outdoor Units
Multi distributor
Pipes

A
Multi distributor
H
Pipes

QUADRUPLE

TRIPLE

E
Outdoor
Units

Accessories
Pipe Kits
MSDD-50TR
Multi distribution pipe twin units - 50:50
- sizes 71/100/125/140

MSDD-50WR
Multi distribution pipe twin units - 50:50
- sizes 200/250

MSDT-111R
Multi distribution pipe triple units - 33:33:33
- sizes 140/200/250

MSDF-1111R
Multi distribution pipe quadruple units - 25:25:25:25
- sizes 200/250

Air Conditioning
1.3.61 1.121

Mr Slim outdoor units can be configured with twin, triple and quad combinations giving added flexibility.
Prices include pipe kits, grilles if required and one remote controller per combination.
TWIN SYSTEMS (Including pipe kit)

DESCRIPTION

(2) PLA-ZRP35BA / (1) PUHZ-ZRP71vHA


(2) PLA-ZRP50BA / (1) PUHZ-ZRP100vKA
(2) PLA-ZRP60BA / (1) PUHZ-ZRP125vKA
(2) PLA-ZRP71BA / (1) PUHZ-ZRP140vKA
(2) PLA-ZRP50BA / (1) PUHZ-ZRP100YKA
(2) PLA-ZRP60BA / (1) PUHZ-ZRP125YKA
(2) PLA-ZRP71BA / (1) PUHZ-ZRP140YKA
(2) PLA-ZRP100BA / (1) PUHZ-RP200YKA
(2) PLA-ZRP125BA / (1) PUHZ-RP250YKA

Power Inverter Cassette, Twin System, Single Phase


Power Inverter Cassette, Twin System, Single Phase
Power Inverter Cassette, Twin System, Single Phase
Power Inverter Cassette, Twin System, Single Phase
Power Inverter Cassette, Twin System, Three Phase
Power Inverter Cassette, Twin System, Three Phase
Power Inverter Cassette, Twin System, Three Phase
Power Inverter Cassette, Twin System, Three Phase
Power Inverter Cassette, Twin System, Three Phase

(2) PLA-RP50BA / (1) PUHZ-P100vHA4


(2) PLA-RP60BA / (1) PUHZ-P125vHA3
(2) PLA-RP71BA / (1) PUHZ-P140vHA3
(2) PLA-RP50BA / (1) PUHZ-P100YHA2
(2) PLA-RP60BA / (1) PUHZ-P125YHA
(2) PLA-RP71BA / (1) PUHZ-P140YHA
(2) PLA-RP100BA / (1) PUHZ-P200YHA3
(2) PLA-RP125BA / (1) PUHZ-P250YHA3

Standard Inverter Cassette, Twin System, Single Phase


Standard Inverter Cassette, Twin System, Single Phase
Standard Inverter Cassette, Twin System, Single Phase
Standard Inverter Cassette, Twin System, Three Phase
Standard Inverter Cassette, Twin System, Three Phase
Standard Inverter Cassette, Twin System, Three Phase
Standard Inverter Cassette, Twin System, Three Phase
Standard Inverter Cassette, Twin System, Three Phase

(2) PLA-ZRP35BA / (1) PUHZ-SHW80vHA


(2) PLA-ZRP50BA / (1) PUHZ-SHW112vHA
(2) PLA-ZRP50BA / (1) PUHZ-SHW112YHA
(2) PLA-ZRP60BA / (1) PUHZ-SHW140YHA

Zubadan Inverter Cassette, Twin System, Single Phase


Zubadan Inverter Cassette, Twin System, Single Phase
Zubadan Inverter Cassette, Twin System, Three Phase
Zubadan Inverter Cassette, Twin System, Three Phase

(2) PKA-RP35HAL / (1) PUHZ-ZRP71vHA


(2) PKA-RP50HAL / (1) PUHZ-ZRP100vKA
(2) PKA-RP60KAL / (1) PUHZ-ZRP125vKA
(2) PKA-RP71KAL / (1) PUHZ-ZRP140vKA
(2) PKA-RP50HAL / (1) PUHZ-ZRP100YKA
(2) PKA-RP60KAL / (1) PUHZ-ZRP125YKA
(2) PKA-RP71KAL / (1) PUHZ-ZRP140YKA
(2) PKA-RP100KAL / (1) PUHZ-RP200YKA

Power Inverter Wall Mounted, Twin System, Single Phase


Power Inverter Wall Mounted, Twin System, Single Phase
Power Inverter Wall Mounted, Twin System, Single Phase
Power Inverter Wall Mounted, Twin System, Single Phase
Power Inverter Wall Mounted, Twin System, Three Phase
Power Inverter Wall Mounted, Twin System, Three Phase
Power Inverter Wall Mounted, Twin System, Three Phase
Power Inverter Wall Mounted, Twin System, Three Phase

(2) PKA-RP50HAL / (1) PUHZ-P100vHA4


(2) PKA-RP60KAL / (1) PUHZ-P125vHA3
(2) PKA-RP71KAL / (1) PUHZ-P140vHA3
(2) PKA-RP50HAL / (1) PUHZ-P100YHA2
(2) PKA-RP60KAL / (1) PUHZ-P125YHA
(2) PKA-RP71KAL / (1) PUHZ-P140YHA
(2) PKA-RP100KAL / (1) PUHZ-P200YHA3

Standard Inverter Wall Mounted, Twin System, Single Phase


Standard Inverter Wall Mounted, Twin System, Single Phase
Standard Inverter Wall Mounted, Twin System, Single Phase
Standard Inverter Wall Mounted, Twin System, Three Phase
Standard Inverter Wall Mounted, Twin System, Three Phase
Standard Inverter Wall Mounted, Twin System, Three Phase
Standard Inverter Wall Mounted, Twin System, Three Phase

(2) PKA-RP50HAL / (1) PUHZ-SHW112vHA


(2) PKA-RP50HAL / (1) PUHZ-SHW112YHA

Zubadan Inverter Wall Mounted, Twin System, Single Phase


Zubadan Inverter Wall Mounted, Twin System, Three Phase

Mr Slim Twin / Triple / Quad Combinations

1.3.62

Mr Slim Twin /
Triple / Quad
Combinations
Inverter Heat Pump Units

TWIN SYSTEMS (Including pipe kit)

DESCRIPTION

(2) PEAD-RP35JAQ / (1) PUHZ-ZRP71vHA


(2) PEAD-RP50JAQ / (1) PUHZ-ZRP100vKA
(2) PEAD-RP60JAQ / (1) PUHZ-ZRP125vKA
(2) PEAD-RP71JAQ / (1) PUHZ-ZRP140vKA
(2) PEAD-RP50JAQ / (1) PUHZ-ZRP100YKA
(2) PEAD-RP60JAQ / (1) PUHZ-ZRP125YKA
(2) PEAD-RP71JAQ / (1) PUHZ-ZRP140YKA
(2) PEAD-RP100JAQ / (1) PUHZ-RP200YKA
(2) PEAD-RP125JAQ / (1) PUHZ-RP250YKA

Power Inverter Ceiling Concealed Ducted, Twin System, Single Phase


Power Inverter Ceiling Concealed Ducted, Twin System, Single Phase
Power Inverter Ceiling Concealed Ducted, Twin System, Single Phase
Power Inverter Ceiling Concealed Ducted, Twin System, Single Phase
Power Inverter Ceiling Concealed Ducted, Twin System, Three Phase
Power Inverter Ceiling Concealed Ducted, Twin System, Three Phase
Power Inverter Ceiling Concealed Ducted, Twin System, Three Phase
Power Inverter Ceiling Concealed Ducted, Twin System, Three Phase
Power Inverter Ceiling Concealed Ducted, Twin System, Three Phase

(2) PEAD-RP50JAQ / (1) PUHZ-P100vHA4


(2) PEAD-RP60JAQ / (1) PUHZ-P125vHA3
(2) PEAD-RP71JAQ / (1) PUHZ-P140vHA3
(2) PEAD-RP50JAQ / (1) PUHZ-P100YHA2
(2) PEAD-RP60JAQ / (1) PUHZ-P125YHA
(2) PEAD-RP71JAQ / (1) PUHZ-P140YHA
(2) PEAD-RP100JAQ / (1) PUHZ-P200YHA3
(2) PEAD-RP125JAQ / (1) PUHZ-P250YHA3

Standard Inverter Ceiling Concealed Ducted, Twin System, Single Phase


Standard Inverter Ceiling Concealed Ducted, Twin System, Single Phase
Standard Inverter Ceiling Concealed Ducted, Twin System, Single Phase
Standard Inverter Ceiling Concealed Ducted, Twin System, Three Phase
Standard Inverter Ceiling Concealed Ducted, Twin System, Three Phase
Standard Inverter Ceiling Concealed Ducted, Twin System, Three Phase
Standard Inverter Ceiling Concealed Ducted, Twin System, Three Phase
Standard Inverter Ceiling Concealed Ducted, Twin System, Three Phase

(2) PEAD-RP35JAQ / (1) PUHZ-SHW80vHA


(2) PEAD-RP50JAQ / (1) PUHZ-SHW112vHA
(2) PEAD-RP50JAQ / (1) PUHZ-SHW112YHA
(2) PEAD-RP60JAQ / (1) PUHZ-SHW140YHA

Zubadan Inverter Ceiling Concealed Ducted, Twin System, Single Phase


Zubadan Inverter Ceiling Concealed Ducted, Twin System, Single Phase
Zubadan Inverter Ceiling Concealed Ducted, Twin System, Three Phase
Zubadan Inverter Ceiling Concealed Ducted, Twin System, Three Phase

(2) PCA-RP50KAQ / (1) PUHZ-ZRP100vKA


(2) PCA-RP60KAQ / (1) PUHZ-ZRP125vKA
(2) PCA-RP71KAQ / (1) PUHZ-ZRP140vKA
(2) PCA-RP50KAQ / (1) PUHZ-ZRP100YKA
(2) PCA-RP60KAQ / (1) PUHZ-ZRP125YKA
(2) PCA-RP71KAQ / (1) PUHZ-ZRP140YKA
(2) PCA-RP100KAQ / (1) PUHZ-RP200YKA
(2) PCA-RP125KAQ / (1) PUHZ-RP250YKA

Power Inverter Ceiling Suspended, Twin System, Single Phase


Power Inverter Ceiling Suspended, Twin System, Single Phase
Power Inverter Ceiling Suspended, Twin System, Single Phase
Power Inverter Ceiling Suspended, Twin System, Three Phase
Power Inverter Ceiling Suspended, Twin System, Three Phase
Power Inverter Ceiling Suspended, Twin System, Three Phase
Power Inverter Ceiling Suspended, Twin System, Three Phase
Power Inverter Ceiling Suspended, Twin System, Three Phase

(2) PCA-RP50KAQ / (1) PUHZ-P100vHA4


(2) PCA-RP60KAQ / (1) PUHZ-P125vHA3
(2) PCA-RP71KAQ / (1) PUHZ-P140vHA3
(2) PCA-RP50KAQ / (1) PUHZ-P100YHA2
(2) PCA-RP60KAQ / (1) PUHZ-P125YHA
(2) PCA-RP71KAQ / (1) PUHZ-P140YHA
(2) PCA-RP100KAQ / (1) PUHZ-P200YHA3
(2) PCA-RP125KAQ / (1) PUHZ-P250YHA3

Standard Inverter Ceiling Suspended, Twin System, Single Phase


Standard Inverter Ceiling Suspended, Twin System, Single Phase
Standard Inverter Ceiling Suspended, Twin System, Single Phase
Standard Inverter Ceiling Suspended, Twin System, Three Phase
Standard Inverter Ceiling Suspended, Twin System, Three Phase
Standard Inverter Ceiling Suspended, Twin System, Three Phase
Standard Inverter Ceiling Suspended, Twin System, Three Phase
Standard Inverter Ceiling Suspended, Twin System, Three Phase

(2) PCA-RP71HAQ / (1) PUHZ-ZRP140vKA


(2) PCA-RP71HAQ / (1) PUHZ-ZRP140YKA

Power Inverter Stainless Steel Ceiling Suspended, Twin System, Single Phase
Power Inverter Stainless Steel Ceiling Suspended, Twin System, Three Phase

(2) PSA-RP71gA / (1) PUHZ-ZRP140vKA


(2) PSA-RP71gA / (1) PUHZ-ZRP140YKA
(2) PSA-RP100gA / (1) PUHZ-RP200YKA
(2) PSA-RP125gA / (1) PUHZ-RP250YKA

Power Inverter Floor Mounted, Twin System, Single Phase


Power Inverter Floor Mounted, Twin System, Three Phase
Power Inverter Floor Mounted, Twin System, Three Phase
Power Inverter Floor Mounted, Twin System, Three Phase

(2) PSA-RP71KA / (1) PUHZ-P140vHA3


(2) PSA-RP71KA / (1) PUHZ-P140YHA
(2) PSA-RP100KA / (1) PUHZ-P200YHA3
(2) PSA-RP125KA / (1) PUHZ-P250YHA3

Standard Inverter Floor Mounted, Twin System, Single Phase


Standard Inverter Floor Mounted, Twin System, Three Phase
Standard Inverter Floor Mounted, Twin System, Three Phase
Standard Inverter Floor Mounted, Twin System, Three Phase

Accessories
MSDD-50TR
Multi distribution pipe twin units - 50:50
- sizes 71/100/125/140

MSDD-50WR
Multi distribution pipe twin units
- 50:50 - sizes 200/250

MSDT-111R
Multi distribution pipe triple units - 33:33:33
- sizes 140/200/250

MSDF-1111R
Multi distribution pipe quadruple units
- 25:25:25:25 - sizes 200/250

Air Conditioning
1.3.63 1.121

TRIPLE SYSTEMS (Including pipe kit)

DESCRIPTION

(3) PLA-ZRP50BA / (1) PUHZ-ZRP140vKA


(3) PLA-ZRP50BA / (1) PUHZ-ZRP140YKA
(3) PLA-ZRP60BA / (1) PUHZ-RP200YKA
(3) PLA-ZRP71BA / (1) PUHZ-RP250YKA

Power Inverter Cassette, Triple System, Single Phase


Power Inverter Cassette, Triple System, Three Phase
Power Inverter Cassette, Triple System, Three Phase
Power Inverter Cassette, Triple System, Three Phase

(3) PLA-RP50BA / (1) PUHZ-P140vHA3


(3) PLA-RP50BA / (1) PUHZ-P140YHA
(3) PLA-RP60BA / (1) PUHZ-P200YHA3
(3) PLA-RP71BA / (1) PUHZ-P250YKA3

Standard Inverter Cassette, Triple System, Single Phase


Standard Inverter Cassette, Triple System, Three Phase
Standard Inverter Cassette, Triple System, Three Phase
Standard Inverter Cassette, Triple System, Three Phase

(3) PKA-RP50HAL / (1) PUHZ-ZRP140vKA


(3) PKA-RP50HAL / (1) PUHZ-ZRP140YKA
(3) PKA-RP60KAL / (1) PUHZ-RP200YKA
(3) PKA-RP71KAL / (1) PUHZ-RP250YKA

Power Inverter Wall Mounted, Triple System, Single Phase


Power Inverter Wall Mounted, Triple System, Three Phase
Power Inverter Wall Mounted, Triple System, Three Phase
Power Inverter Wall Mounted, Triple System, Three Phase

(3) PKA-RP50HAL / (1) PUHZ-P140vHA3


(3) PKA-RP50HAL / (1) PUHZ-P140YHA
(3) PKA-RP60KAL / (1) PUHZ-P200YHA3
(3) PKA-RP71KAL / (1) PUHZ-P250YHA3

Standard Inverter Wall Mounted, Triple System, Single Phase


Standard Inverter Wall Mounted, Triple System, Three Phase
Standard Inverter Wall Mounted, Triple System, Three Phase
Standard Inverter Wall Mounted, Triple System, Three Phase

(3) PEAD-RP50JAQ / (1) PUHZ-ZRP140vKA


(3) PEAD-RP50JAQ / (1) PUHZ-ZRP140YKA
(3) PEAD-RP60JAQ / (1) PUHZ-RP200YKA
(3) PEAD-RP71JAQ / (1) PUHZ-RP250YKA

Power Ceiling Concealed Ducted, Triple System, Single Phase


Power Ceiling Concealed Ducted, Triple System, Three Phase
Power Ceiling Concealed Ducted, Triple System, Three Phase
Power Ceiling Concealed Ducted, Triple System, Three Phase

(3) PEAD-RP50JAQ / (1) PUHZ-P140vHA3


(3) PEAD-RP50JAQ / (1) PUHZ-P140YHA
(3) PEAD-RP60JAQ / (1) PUHZ-P200YHA3
(3) PEAD-RP71JAQ / (1) PUHZ-P250YHA3

Standard Ceiling Concealed Ducted, Triple System, Single Phase


Standard Ceiling Concealed Ducted, Triple System, Three Phase
Standard Ceiling Concealed Ducted, Triple System, Three Phase
Standard Ceiling Concealed Ducted, Triple System, Three Phase

(3) PCA-RP50KAQ / (1) PUHZ-ZRP140vKA


(3) PCA-RP50KAQ / (1) PUHZ-ZRP140YKA
(3) PCA-RP60KAQ / (1) PUHZ-RP200YKA
(3) PCA-RP71KAQ / (1) PUHZ-RP250YKA

Power Inverter Ceiling Suspended, Triple System, Single Phase


Power Inverter Ceiling Suspended, Triple System, Three Phase
Power Inverter Ceiling Suspended, Triple System, Three Phase
Power Inverter Ceiling Suspended, Triple System, Three Phase

(3) PCA-RP50KAQ / (1) PUHZ-P140vHA3


(3) PCA-RP50KAQ / (1) PUHZ-P140YHA
(3) PCA-RP60KAQ / (1) PUHZ-P200YHA3
(3) PCA-RP71KAQ / (1) PUHZ-P250YHA3

Standard Inverter Ceiling Suspended, Triple System, Single Phase


Standard Inverter Ceiling Suspended, Triple System, Three Phase
Standard Inverter Ceiling Suspended, Triple System, Three Phase
Standard Inverter Ceiling Suspended, Triple System, Three Phase

(3) PCA-RP71HAQ / (1) PUHZ-RP250YKA


(3) PCA-RP71HAQ / (1) PUHZ-P250YHA3

Power Inverter Stainless Steel Ceiling Suspended, Triple System, Three Phase
Standard Inverter Stainless Steel Ceiling Suspended, Triple System, Three Phase

(3) PSA-RP71gA / (1) PUHZ-RP250YKA

Power Inverter Floor Mounted, Triple System, Three Phase

(3) PSA-RP71gA / (1) PUHZ-P250YHA3

Standard Inverter Floor Mounted, Triple System, Three Phase

Mr Slim Twin / Triple / Quad Combinations

1.3.64

Mr Slim Twin /
Triple / Quad
Combinations
Inverter Heat Pump Units

QUAD SYSTEMS (Including pipe kit)

DESCRIPTION

(4) PLA-RP50BA / (1) PUHZ-RP200YKA


(4) PLA-RP60BA / (1) PUHZ-RP250YKA

Power Inverter Cassette, Quadruple System, Three phase


Power Inverter Cassette, Quadruple System, Three phase

(4) PLA-RP50BA / (1) PUHZ-P200YHA3


(4) PLA-RP60BA / (1) PUHZ-P250YHA3

Standard Inverter Cassette, Quadruple System, Three phase


Standard Inverter Cassette, Quadruple System, Three phase

(4) PKA-RP50HAL / (1) PUHZ-RP200YKA


(4) PKA-RP60KAL / (1) PUHZ-RP250YKA

Power Inverter Wall Mounted, Quadruple System, Three Phase


Power Inverter Wall Mounted, Quadruple System, Three Phase

(4) PKA-RP50HAL / (1) PUHZ-P200YHA3


(4) PKA-RP60KAL / (1) PUHZ-P250YHA3

Standard Inverter Wall Mounted, Quadruple System, Three Phase


Standard Inverter Wall Mounted, Quadruple System, Three Phase

(4) PEAD-RP50JAQ / (1) PUHZ-RP200YKA


(4) PEAD-RP60JAQ / (1) PUHZ-RP250YKA

Power Inverter Ceiling Concealed Ducted, Quadruple System, Three Phase


Power Inverter Ceiling Concealed Ducted, Quadruple System, Three Phase

(4) PEAD-RP50JAQ / (1) PUHZ-P200YHA3


(4) PEAD-RP60JAQ / (1) PUHZ-P250YHA3

Standard Inverter Ceiling Concealed Ducted, Quadruple System, Three Phase


Standard Inverter Ceiling Concealed Ducted, Quadruple System, Three Phase

(4) PCA-RP50KAQ / (1) PUHZ-RP200YKA


(4) PCA-RP60KAQ / (1) PUHZ-RP250YKA

Power Inverter Ceiling Suspended, Quadruple System, Three Phase


Power Inverter Ceiling Suspended, Quadruple System, Three Phase

(4) PCA-RP50KAQ / (1) PUHZ-P200YHA3


(4) PCA-RP60KAQ / (1) PUHZ-P250YHA3

Standard Inverter Ceiling Suspended, Quadruple System, Three Phase


Standard Inverter Ceiling Suspended, Quadruple System, Three Phase

Outdoor Units
Product Dimensions
Upper View

Front View

175

600

Handle for moving


2-U Shaped notched holes
(Foundation Bolt M10)

Side View

PUHZ-ZRP35/50VKA

Upper View

Front View

404.5

Earth terminal

Air intake

Handle for moving

42 drain hole

22.3

48

Installation Feet

300
330

360

Service panel

Earth terminal

417

Air intake

40

630

Service panel

8.5

Connection for
gas pipe
FLARE 12.7 (1/2F)

154.5

1 447

371

1 443

4-1021 oval hole

Connection for
liquid pipe
FLARE 6.35 (1/4F)

320

Air discharge

32.5

Handle for moving

635

2-12 x 36 Oval holes


(Foundation Bolt M10)

1350

Air Discharge

42

Handle
for
moving

Service panel
for charge plug

53
28

30

45
56
370

330

Side Air Intake

66

310

Service port
Installation bolt pitch
500

Product Dimensions

PUHZ-ZRP60/71VHA
Front View

Side View

Upper View

Front View
Rear air intake

950
Handle for moving

Earth terminal

943

30

417

70

60

42

Earth terminal

56
40
0
53

2-12 36 Oval holes


(foundation bolt M10)

Service panel

Handle for moving

447

369

431

473

Air intake

23

Air discharge
Front piping cover
Rear piping cover

Air Conditioning
1.3.65 1.121

362

673

Air discharge

28

2-12 36 oval holes


(foundation bolt M10)

Handle for moving

370

40
54
53

30

41

1050
2 U-shaped notched holes
(Foundation Bolt M10)
225

Side air intake

Handle for moving

57

600
Installation Feet

442
450

Installation Feet

322

Service panel

19

175

330

Side air intake

600

225

370
417

2 U-shaped notched holes


(Foundation Bolt M10)

330

Rear air intake

Side View

Model
PUHZ-ZRP100~140VKA
PUHZ-ZRP100~140YKA

A
1067
919

26

Upper View

PUHZ-ZRP100/125/140VKA, PUHZ-ZRP100/125/140YKA

632

Product Dimensions

1338

930

19

SHWYHA

Front piping cover


Rear piping cover

28

1079

62

809

23

SHWVHA

175

Side View

950
322

175
(19)

Rear Air Intake

Product Dimensions

PUHZ-SHW80/112VHA, PUHZ-SHW112/140YHA

Outdoor Unit Product Dimensions

Front piping cover


Rear piping cover

1.3.66

Outdoor Units
Product Dimensions
Upper View

Front View

Handle for moving

Rear air intake


2 U-shaped notched holes
(foundation bolt M10)
225

600
Installation Feet

362

Side View

PUHZ-P100VHA4, PUHZ-P100YHA2

Upper View

1050
Earth terminal

Front View

Rear Air Intake

2-U Shaped notched holes


(Foundfation Bolt M10)

Side View

950
Handle for moving

322

Earth terminal

19

175

Side air intake

600

175

Service panel

(19)

Handle for moving

943

E
F

Front View

Side View

B
1 A

A B C
PUHZ-P100VHA4 443 670 66
PUHZ-P100YHA2 431 589 56

D
42
41

Product Dimensions

PUHZ-P200/250YHA3

E
45
41

Upper View

F
56
54

Front View

950

Handle for moving

322

Rear Air Intake


Earth terminal

175

175

Installation Feet

600

950
2-U Shaped notched holes
(Foundation Bolt M10)

Handle for moving

322

Earth terminal

175

Installation Feet

Side Air Intake

Side View

(19)

2-U Shaped notched holes


(Foundation Bolt M10)

(19)

600

473
23

PUHZ-P125/140VHA3, PUHZ-P125/140YHA

Upper View

417

330

417

41
54
370

330

Side Air Intake


40
56
370

175

Front piping cover


Rear piping cover

Front piping cover


Rear piping cover

Product Dimensions

Rear Air Intake

28

30

982
986

B
442

2-12 x 36 oval holes


(Foundation Bolt M10)

342
*1 A
*1 B

369

Brazing

Air Discharge

Air intake

53

Handle for moving

26

A
450
424

Model
PUHZ-RP200YKA
PUHZ-RP250YKA

370
417

330

1338

42

2-12 36 oval holes


(foundation bolt M10)

Air discharge

Side Air Intake

Service panel
632

60

70

56
40
0
53
28

30

330

370
417

Installation Feet

1 447

225

Product Dimensions

PUHZ-RP200/250YKA

Service panel

995
999

2-12 x 36 Oval holes


(Foundation Bolt M10)

Handle for moving

635

Air Discharge

37

1350

61

53
28

30
Handle for moving

635

2-12 x 36 Oval holes


(Foundation Bolt M10)

1350

Air Discharge

41

53
28

30

Service panel

56

PUHZ-P200YHA3
PUHZ-P250YHA3

A
447
421

1 439

2 339

1A

371

1 447
Front piping cover
Rear piping cover

23

A
PUHZ-P125/140VHA3 1076
PUHZ-P125/140YHA
994

23

371

1 431

Brazing

Front piping cover


Rear piping cover

Outdoor Units
Product Dimensions
Upper View

400
Air in

Product Dimensions

SUZ-KA25/35VA4
Front View

Side View

Upper View

23

22.3

Front View

Side View

417.5

Service panel

Drain hole

SUZ-KA50/60/71VA4

Drain hole
40

Air in

42

840

81
Service panel

360

880

164.5

99.5

800

500

44

Service port

500 Bolt pitch for installation

2-holes 10 21
175

452

170.5

Liquid refrigerant
pipe joint
Refrigerant pipe
(flared)

35

302.5

50

330
35
164.5

69

43

550

150

Air out
Gas refrigerant pipe joint
Refrigerant pipe (flared)
99.5

Air out

10

40

2 holes 10X21

17.5

Air in

280

Bolt pitch for


installation
304~325

44

285

344.5

109
Liquid refrigerant pipe joint
Refrigerant pipe (flared)

Handle

195

Air Conditioning
1.3.67 1.121

Outdoor Unit Product Dimensions

Gas refrigerant
pipe joint
Refrigerant pipe
(flared)

1.3.68

Mr Slim
Accessories /
Optional Extras
Indoor Units

WALL MOUNTED SYSTEMS


S70 515 716
S71 000 028

CEILING CONCEALED DUCTED UNITS


MAC-333IF
MAC-397IF

4-WAY BLOW CASSETTE UNITS


PLP-6BA
SLP-2AAW
PAC-SH53TM
PAC-SH59KF
PLP-6BALM
PLP-6BAJ
PAC-SA1ME
PAR-SA9FA
PAR-SL97A

CEILING SUSPENDED UNITS


PAR-SL94B
PAC-SH83DM
PAC-SH84DM
PAC-SH85DM
PAC-Sg38KF
PAC-SF81KC

DESCRIPTION

Terminal block
CN22 connector

DESCRIPTION

Interface for group control, run fault and connection to M-NET System
for SEZ-KD25-71VAQ
Interface for group control and run/fault SEZ-KD25-71VAQ

DESCRIPTION

Grille for PLA-RP35-140BA(2) and PLA-ZRP35-140BA


Grille for SLZ-KA25-50VAQ
Multi function casement PLA-RP35-140BA(2) and PLA-ZRP35-140BA for
fresh air 100mm knockout or to hold the high efficiency filter option
High efficiency filter PLA-RP35-140BA(2) and PLA-ZRP35-140BA
Grille and infra-red controller PLA-RP35-140BA(2) and PLA-ZRP35-140BA
Grille with filter lowering function PLA-RP35-140BA(2) and PLA-ZRP35-140BA
Corner panel i-see sensor PLA-RP35-140BA(2) and PLA-ZRP35-140BA
Infra-red signal receiver PLA-RP35-140BA(2) and PLA-ZRP35-140BA
Infra-red controller PLA-RP35-140BA(2) and PLA-ZRP35-140BA

DESCRIPTION

Wireless remote controller and adaptor


Optional drain lift pump for PCA-RP50KAQ
Optional drain lift pump for PCA-RP71-140KAQ
Optional drain lift pump for PCA-RP60KAQ
Oil mist filter for PCA-RP71HAQ (12 pack)
Decoration covers (front cover & suspending bracket) for PCA-RP71HAQ

Mr Slim
Accessories /
Optional Extras
Outdoor Units /
System Control Units /
Power Supply Terminal Kits

OUTDOOR UNITS
PAC-SJ08DS
PAC-Sg61DS
PAC-SJ07Sg
PAC-Sg59Sg
PAC-SH96Sg
PAC-SJ06Sg
PAC-SH63Ag
PAC-SH95Ag

SYSTEM CONTROL UNITS


PAC-SA89TA
PAC-SA88HA
PAC-SF40RM
MAC-333IF
MAC-397IF
PAC-SE41TS
MAC-557IF
PAC-SJ19MA
PAC-SF83MA
PAC-YT52CRA
PAR-31MAA
PAC-SK84SI
PAC-SK83SI

POWER SUPPLY TERMINAL KITS


PAC-SH52HR
PAC-Sg94HR
PAC-Sg96HR
PAC-Sg97HR

Air Conditioning
1.3.69 1.121

DESCRIPTION

Drain socket set for PUHZ-ZRP35-50


Drain socket set for PUHZ-P / PUHZ-ZRP / PUHZ-SHW for size 60-140
Air outlet guide for PUHZ-ZRP35-50
Air outlet guide for PUHZ-ZRP60-71 / PUHZ-P100-250 / PUHZ-SHW
Air outlet guide for PUHZ-ZRP100-250 / PUHZ-RP200-250
Air protect guide (allows cooling at -15C) for PUHZ-ZRP35-50
Air protect guide (allows cooling at -15C) for PUHZ-ZRP60-71 /
PUHZ-P100-250 / PUHZ-SHW
Air protect guide (allows cooling at -15C) for PUHZ-ZRP100-250 /
PUHZ-RP200-250
DESCRIPTION

Remote on/off adaptor


Run/fault adapter
Run/fault interface
Interface for group control, run fault and connection to M-NET System
for SEZ-KD25-71VAQ
Interface for group control and run/fault SEZ-KD25-71VAQ
Remote sensor
MELCloud WiFi interface
A/M-NET adaptor for PUHZ-ZRP35-50
A/M-NET adaptor for PUHZ-ZRP60-250 / PUHZ-P100-250 / PUHZ-SHW
Simplified remote controller
Remote controller
Sub interface board for PUHZ-ZRP35-50 (required for A32M and BAC-A/50)
Sub interface board for PUHZ-ZRP60-250 / PUHZ-P100-250 / PUHZ-SHW
(required for A32M and BAC-A/50)
DESCRIPTION

Power supply terminal kit for PLA-RP and PLA-ZRP


Power supply terminal kit for PKA-RP
Power supply terminal kit for PCA-RP / PSA-RP
Power supply terminal kit for PEAD-RP / PCA-RP-HAQ

Mr Slim Accessories / Optional Extras

Multi-Splits
Split-System Air Conditioning

The Flexible & Efficient

Ideal for shops and small commercial buildings that require air conditioning
in more than one room, the Mitsubishi Electric Multi-Split systems combine
flexibility and performance while lowering CO2 emissions and running costs.

Range

Using R410A refrigerant and flexible enough to suit a number of applications, the range includes models that will run up
to eight indoor units per single outdoor unit, between 5.3 and 15.5kW.

Multi-Split

With vastly reduced power consumption, inverter technology and with increased pipe length and advanced controls,
the Multi-Split range is extremely efficient and versatile, helping to make system application easier.
A variety of indoor units can be connected to a single outdoor unit, these include cassettes, ducted, wall, floor or ceiling mounted.
The range has been completely redesigned to meet the new Ecodesign Directive for Energy Related Products (ErP).
This enables the range to be one of the most efficient in the industry with energy efficiency class up to A++.

Example of a 6-way Multi-Split System

1.4.3

1.121
Air Conditioning

The Flexible & Efficient Multi-Split Range

1.4.4

The Flexible & Efficient

Multi-Split

Range

Features
Inverter Technology
Multi-Split outdoor units utilise Inverter technology to save energy and thus running costs for two main reasons:
One: The compressor varies its speed to match the cooling or heating load and therefore consumes only the power
necessary to match the exact requirement of the room.
Two: When an inverter driven air conditioner is operating at partial load, the energy efficiency
of the system is higher than at full load.

Individual Control of Units


All indoor units that form part of a Multi-Split system can be individually controlled (On/Off and Setpoint)
according to the need of the room or location it is installed.
This saves energy where rooms are maybe out of use, as well as allowing for individual
preference on room temperature.

Operational Range
Operation range

MXZ

Cooling

-10C to +46C

Heating

-15C to +24C

Nominal Conditions: Cooling; indoor 27C DB, 19C WB; outdoor 35C DB, 24C WB.
Nominal Conditions: Heating; indoor 20C DB; outdoor 7C DB, 6C WB.
UK Conditions: Summer; indoor 21C DB, 15C WB; outdoor 27C DB.
UK Conditions: Winter; indoor 21C DB; outdoor 0C DB, -1C WB.

The Flexible & Efficient

Multi-Split

Range

Applications

Versatile System Design


The system is an ideal choice for small commercial properties desiring a flexible and effective solution
with regards to system design.
Available to configure in two variants, the 2-6 port Multi-Split systems have each indoor unit connected to the outdoor unit,
whereas the 8 port power Multi-Split system utilises 3 way and 5 way branch boxes to realise indoor unit connection.
Adding to the flexible piping design, the total piping length ranges from
30 to 115m and maximum height difference from 10 to 30m.
Outdoor Unit

Multi-Split office application

Power Multi-Split executive suite application

Branch
Boxes

Outdoor Unit

1.4.5

1.121
Air Conditioning

The Flexible & Efficient Multi-Split Range

1.4.6

The Flexible & Efficient

Multi-Split
Range

Outdoor Units

MXZ-2D53VA
2 indoor units
Nominal cooling capacity 5.3kW

MXZ-3D54VA2

MXZ-4D72VA

2-3 indoor units


Nominal cooling capacity 5.4kW

2-4 indoor units


Nominal cooling capacity 7.2kW

MXZ-4D83VA

MXZ-5D102VA

2-4 indoor units


Nominal cooling capacity 8.3kW

2-5 indoor units


Nominal cooling capacity 10.2kW

MXZ-6C122VA
2-6 indoor units
Nominal cooling capacity 12.2kW

MXZ-8B140VA

MXZ-8B160YA

2-8 indoor units


Nominal cooling capacity 14.0kW

2-8 indoor units


Nominal cooling capacity 15.5kW

Branch Boxes
PAC-AK32BC

PAC-AK53BC

The Flexible & Efficient

Multi-Split
Range

Indoor Units

Wall Mounted

Ceiling Concealed Ducted

MSZ-EF-VEB
Zen Series

SEZ-KD Series

MSZ-EF-VES
Zen Series
MSZ-EF-VEW
Zen Series
MSZ-SF/GF Series

MSZ-FH Series

1.4.7

1.121
Air Conditioning

PEAD-RP Series

Ceiling Cassette
SLZ-KA Series

PLA-RP Series

Floor Mounted

Ceiling Suspended

MSZ-KJ Series

PCA-RP Series

The Flexible & Efficient Multi-Split Range

1.4.8

The Flexible & Efficient

Multi-Split
Range

Model

Wall Mounted
MSZ-SF20VA
MSZ-SF25VE
MSZ-SF35VE
MSZ-SF50VE
MSZ-FH25VE
MSZ-FH35VE
MSZ-EF25VEB/S/W
MSZ-EF35VEB/S/W
MSZ-EF50VEB/S/W

Compatibility
Table

MSZ-GF60VE
MSZ-GF71VE
Floor Mounted
MFZ-KJ25VE
MFZ-KJ35VE
MFZ-KJ50VE
Ducted
SEZ-KD25VAQ*3
SEZ-KD35VAQ
SEZ-KD50VAQ
SEZ-KD60VAQ
SEZ-KD71VAQ
PEAD-RP50JAQ*1
PEAD-RP60JAQ*1
PEAD-RP71JAQ*1
Ceiling Cassette
SLZ-KA25VAQ
SLZ-KA35VAQ
SLZ-KA50VAQ
PLA-RP35BA
PLA-RP50BA
PLA-RP60BA
PLA-RP71BA
PLA-RP100BA*2
Ceiling Suspended

*1 Total capacity of indoor units must not exceed 100% if PEAD-RP is used.

PCA-RP50KAQ

*2 Can only be connected using a PAC-AK53BC with a PAC-AK52YP-E connection pipe.

PCA-RP60KAQ

*3 The SEZ-KD25VAQ cannot be used when the total indoor capacity is equal to the
outdoor capacity i.e. when the capacity ratio is 1.

PCA-RP71KAQ

MXZ-2D53VA MXZ-3D54VA2 MXZ-4D72VA MXZ-4D83VA MXZ-5D102VA MXZ-6C122VA MXZ-8B140VA MXZ-8B160YA

The Flexible & Efficient

Multi-Split

Range

Contents

1.4.9

1.121
Air Conditioning

MXZ-D/C Multi-Split Inverter Heat Pump

1.4.10

MXZ-8B Power Multi-Split Inverter Heat Pump

1.4.12

Multi-Split Combinations

1.4.14

The Flexible & Efficient Multi-Split Range

1.4.10

MXZ-D/C
Inverter Heat Pump
(5.3-12.2kW)
Multi-Split Units

The Multi-Split system allows up to six M Series or Mr Slim wall mounted, cassette, ducted, floor or
ceiling mounted indoor unit heat pumps of different capacities to be operated from a single outdoor unit.
This makes it an economic answer in multi-room applications, whilst also offering space saving benefits.

Key Features
Up to six indoor units may be connected to a single outdoor unit
Energy saving inverter controlled outdoor unit adjusts compressor performance to economically match the demand for heating and cooling
Units may be added within the capacity of the system as requirements change
Capacities of indoor units may be mixed to suit individual rooms
Size 83, 102 and 122 have current limit adjustment for managing energy costs. They also feature a wiring/piping correction function to analyse
the system for connection errors via the press of a single button

MULTI-SPLIT - INDOOR UNITS

MFZ-KJ25/35VE

MSZ-SF20/25/35/50VE / MSZ-FH25/35VE
MSZ-EF25/35/50VEB/S/W

MFZ-KJ25/35/50VE

MXZ-4D72VA

MSZ-SF20/25/35/50VE / MSZ-GF60VE
MSZ-FH25/35VE / MSZ-EF25/35/50VEB/S/W

MFZ-KJ25/35/50VE

MXZ-4D83VA

MSZ-SF20/25/35/50VE / MSZ-GF60/71VE
MSZ-FH25/35VE / MSZ-EF25/35/50VEB/S/W

MFZ-KJ25/35/50VE

MXZ-5D102VA

MSZ-SF20/25/35/50VE / MSZ-GF60/71VE
MSZ-FH25/35VE / MSZ-EF25/35/50VEB/S/W

MFZ-KJ25/35/50VE

MXZ-6C122VA

MSZ-SF20/25/35/50VE / MSZ-GF60/71VE
MSZ-FH25/35VE / MSZ-EF25/35/50VEB/S/W

MFZ-KJ25/35/50VE

MXZ-D/C - OUTDOOR UNITS

*1 Combined max running current of all indoors on system must not exceed 3A if PEAD-RP is used.
*2 System COP / EER when connected to MSZ-EF x indoor unit connections.
*3 The SEZ-KD25VAQ cannot be used when the total indoor capacity is equal to the outdoor
capacity i.e. when the capacity ratio is 1.

FLOOR MOUNTED

MXZ-3D54VA2

MXZ-2D53VA

Notes:

WALL MOUNTED
MSZ-SF20/25/35VE / MSZ-FH25/35VE
MSZ-EF25/35/50VEB/S/W

MXZ-2D53VA

NUMBER OF CONNECTABLE INDOOR UNITS


2
CAPACITy (kW)
Heating (nominal)
6.4 (1.0-7.0)
Cooling (nominal)
5.3 (1.1-5.6)
Heating (UK)
5.3 (0.83-5.81)
Cooling (UK)
5.2 (1.09-5.55)
COP / EER (nominal)*2
3.76 / 3.44
4.2 / 7.1
SCOP / SEER (BSEN14825)
A+ / A++
ErP ENERGy EFFICIENCy CLASS Heating/Cooling
33.3 / 32.9
MAX AIRFLOW (m3/min)
Heating/Cooling
53 / 50
SOUND PRESSURE LEVEL (dBA)
Heating/Cooling - Sil-Hi
64
SOUND POWER LEVEL (dBA)
Cooling
800 x 285 x 550
DIMENSIONS (mm)
Width x Depth x Height
37
WEIGHT (kg)
220-240v, 50Hz
ELECTRICAL SUPPLy
Single
PHASE
1.70 / 1.54
POWER INPUT (kW)
Heating/Cooling (nominal)
1.54 / 1.23
Heating/Cooling (UK)
7.6
STARTING CURRENT (A)
7.6 / 6.9 [12.2]
RUNNING CURRENT (A)
Heating/Cooling [MAX]
4 Core
INTERCONNECTING CABLE No. CORES
30
TOTAL PIPE LENGTH (m)
20
MAX PIPE LENGTH PER INDOOR UNIT (m)
15 (10 if OU higher than IU)
MAX HEIGHT DIFFERENCE (m)
1.30 [20m]
CHARGE R410A (kg) [Precharged Length]
15
FUSE RATING (BS88) HRC (A)

MXZ-3D54VA2
2-3
7.0 (2.6-9.0)
5.4 (2.9-6.8)
5.8 (2.16-7.47)
5.3 (2.87-6.74)
4.40 / 4.00
4.0 / 6.4
A+ / A++
43.0 / 42.1
53 / 50
64
840 x 330 x 710
57
220-240v, 50Hz
Single
1.59 / 1.35
1.44 / 1.08
7.0
7.0 / 6.1 [18]
4 Core
50
25
15 (10 if OU higher than IU)
2.70 [40m]
25

MXZ-4D72VA

DUCTED

CEILING CASSETTE
*3

SEZ-KD25/35VAQ

SLZ-KA25/35VAQ

SEZ-KD25/35/50VAQ*3
PEAD-RP50JAQ*1
SEZ-KD25/35/50/60VAQ*3
PEAD-RP50JAQ*1
SEZ-KD25/35/50/60/71VAQ*3
PEAD-RP50/60/71JAQ*1
SEZ-KD25/35/50/60/71VAQ*3
PEAD-RP50/60/71JAQ*1
SEZ-KD25/35/50/60/71VAQ*3
PEAD-RP50/60/71JAQ*1

SLZ-KA25/35/50VAQ
PLA-RP50BA
SLZ-KA25/35/50VAQ
PLA-RP50/60BA
SLZ-KA25/35/50VAQ
PLA-RP50/60/71BA

MXZ-4D83VA

SLZ-KA25/35/50VAQ
PLA-RP50/60/71BA
SLZ-KA25/35/50VAQ
PLA-RP50/60/71BA

MXZ-5D102VA

CEILING DUCTED
PCA-RP50KAQ
PCA-RP50/60KAQ
PCA-RP50/60/71KAQ
PCA-RP50/60/71KAQ

PCA-RP50/60/71KAQ

MXZ-6C122VA

2-4
2-4
2-5
2-6
8.6 (3.4-10.7)
9.4 (3.4-11.6)
10.5 (4.1-14.0)
14.0 (3.5-16.5)
7.1 (3.7-8.8)
8.3 (3.7-9.2)
10.2 (3.9-11.0)
12.2 (3.5-13.5)
7.1 (2.82-8.89)
7.8 (2.82-9.63)
8.7 (3.40-11.63)
11.6 (2.90-13.71)
7.0 (3.67-8.72)
8.2 (3.67-9.12)
10.1 (3.86-10.90)
12.1 (3.47-13.39)
3.77 / 3.20
3.72 / 2.93
3.62 / 2.61
3.67 / 3.01
3.9 / 5.7
3.9 / 5.2
3.8 / 5.3
-/A+ / A+
A/A
A/A
N/A
43.0 / 42.1
43.8 / 42.1
59.3 / 56.6
69.9 / 59.5
53 / 50
50 / 49
55 / 53
57 / 55
64
64
68
69
840 x 330 x 710
900 x 320 x 915
900 x 320 x 915
900 x 320 x 1070
58
69
70
87
220-240v, 50Hz
220-240v, 50Hz
220-240v, 50Hz
220-240v, 50Hz
Single
Single
Single
Single
2.28 / 2.25
2.42 / 2.83
2.90 / 3.91
3.81 / 4.05
2.07 / 1.80
2.20 / 2.26
2.63 / 3.12
3.46 / 3.21
10.0
12.4
17.2
18.0
10.0 / 9.9 [18]
10.6 / 12.4 [20.4]
12.7 / 17.2 [21.4]
16.7 / 17.8 [30]
4 Core
4 Core
4 Core
4 Core
60
70
80
80
25
25
25
25
15 (10 if OU higher than IU) 15 (10 if OU higher than IU) 15 (10 if OU higher than IU) 15 (10 if OU higher than IU)
2.70 [40m]
3.50 [40m]
4.0 [40m]
4.8 [60m]
25
25
25
32

Product Dimensions
Upper View

Outdoor Units

Front View

400

Air outlet guides for MXZ-2D53VA

13

51 51 51

251.1

251.1

51 51 51

550
280

550
280

344.5

304~325

17.5

10

10

302.5

170.4

302.5

150

150500

500

800

800

170.4

2-1021 Oval hole

Product Dimensions

69

69

MXZ-3D54VA2, MXZ-4D72VA

Upper View

MAC-333IF

Side View

Front View
840840

30 30
25.8

200200

13

240
240

66.3

360
360

45
45
225
225
440
440

710
710

396

1 7 .7

1 7 .7

18.3

Air out
Air out

27.1
27.1
Connecting
Connecting
Wire
Hole
Wire
Hole
(3927)
(3927)
360.6
(Bolt
Pitch)
(Bolt396
Pitch)

Air in
Air in

Air in
Air in

MAC-557IF

330

171171

12.3 360.6 18.3

500500
314314

34

16.6
34

16.6

207.5
207.5

12.3

169169
65.465.4

1 7 .7

Drain
3-33
Drain
holehole
3-33

84
84

Interface for Contact Terminal and PAR-31MAA /


PAC-yT52CRA Wired Remote Controller

285 1 3

40
Air out

Air outlet guides for MXZ-6C122VA

MAC-397IF

1 8 285

18

Drain hole 42 (In case of Base heater models 33)

Air in

MAC-857SG

Interface for group control, run fault and connection


to M-NET System

Side View

22.3
Handle

Air in

Air outlet guides for MXZ-3D54VA2, MXZ-4D72VA,


MXZ-4D83VA, MXZ-5D102VA

System Control Units

22.3

Handle

MAC-889SG
MAC-856SG

MXZ-2D53VA

1 7 .7

Accessories

Interface for connection to WiFi MELCloud service

Product Dimensions

*MXZ-4D72VA has 4 pipe connections

23.1
23.1

299299

MXZ-4D83VA, MXZ-5D102VA

Upper View

Front View

Side View 25

900
900

25

320

320
10

10

Handle
Handle

200

500

200

Indoorand
and
Indoor
outdoor
outdoor
connectwiring
wiring
connect
(3553)hole
hole
(3553)

16

Handle
Handle

915
915
45
45

612
612

405
405

16

147
147

42

40

Air out

Drain hole

475
475

24

Air in

(Bolt pitch)
387

355

11

Air in

27

42

315

Product Dimensions

MXZ-6C122VA

Upper View

48

900

Side View

900

200
Rear Air
Intake

Connecting
Connecting
Wire Hole
Wire Hole
(36 x 96)
(36 x 96)

27

500
450

Front View

16

200

*MXZ-4D83VA has 4 pipe connections

23
23

317
317

21

320

Handle

515
65
730
515 1070
730
1070

340

Air Conditioning
1.4.11 1.121

340

34

125

65
45

125

548

45

387

HandleHandle

548

Air
Discharge

16

42 Drain Hole

40

24

355
(Bolt Pitch)

11

70

Side Air Intake

34

The Flexible & Efficient Multi-Split Range

1.4.12

MXZ-8B
Power Multi-Split
(14-15.5kW)
Inverter Heat Pump
Multi-Split Units

The Power Multi-Split systems allow up to eight M Series or Mr Slim cassette, ducted, floor, ceiling
or wall mounted indoor units of different capacities to be operated from a single outdoor unit, making
use of two types of branch box to achieve this. This makes them an economic answer in multi-room
applications and ideal for small commercial buildings.

Key Features
14 and 15.5kW Inverter Multi Systems, based on Mr Slim Power Inverter technology
Total pipe length of 115m / Height difference of 30m
Individual control of each indoor unit is now possible (ON/OFF & Setpoint)
Low starting and running currents
Connection to M-NET system via MAC-333IF interface (one per indoor unit)
Current limit adjustment for managing energy costs

MULTI-SPLIT - INDOOR UNITS

WALL MOUNTED

FLOOR MOUNTED

DUCTED

CEILING CASSETTE

MXZ-8B140VA

MSZ-SF20/25/35/50VE / MSZ-GF60/71VE
MSZ-FH25/35VE / MSZ-EF25/35/50VEB/S/W

MFZ-KJ25/35/50VE

SEZ-KD25/35/50/60/71VAQ
PEAD-RP50/60/71JAQ*1

SLZ-KA25/35/50VAQ
PLA-RP35/50/60/71BA / PLA-RP100BA*2

MXZ-8B160yA

MSZ-SF20/25/35/50VE / MSZ-GF60/71VE
MSZ-FH25/35VE / MSZ-EF25/35/50VEB/S/W

MFZ-KJ25/35/50VE

SEZ-KD25/35/50/60/71VAQ
PEAD-RP50/60/71JAQ*1

SLZ-KA25/35/50VAQ
PLA-RP35/50/60/71BA / PLA-RP100BA*2

*1 Total capacity of indoor units must not exceed 100% if PEAD-RP is used. *2 Can only be connected using a PAC-AK53BC with a PAC-AK52YP pipe.

MXZ-8B - OUTDOOR UNITS


NUMBER OF CONNECTABLE INDOOR UNITS
CAPACITy (kW)
Heating (nominal)
Cooling (nominal)
Heating (UK)
Cooling (UK)
COP / EER (nominal)
Outdoor Only
ENERGy LABEL
Heating/Cooling
MAX AIRFLOW (m3/min)
SOUND PRESSURE LEVEL (dBA) Heating/Cooling - Sil-Hi
DIMENSIONS (mm)
Width x Depth x Height
WEIGHT (kg)
ELECTRICAL SUPPLy
PHASE
POWER INPUT (kW)
Heating/Cooling (nominal)
Heating/Cooling (UK)
STARTING CURRENT (A)
RUNNING CURRENT (A) [MAX] Heating/Cooling
INTERCONNECTING CABLE No. CORES
TOTAL PIPE LENGTH (m)
MAX PIPE LENGTH PER INDOOR UNIT (m)
FURTHEST PIPE LENGTH - Outdoor to Indoor (m)
MAX HEIGHT DIFFERENCE - Outdoor to Indoor (m)
MAX HEIGHT DIFFERENCE - Indoor to Indoor (m)
CHARGE R410A (kg) - 40m
FUSE RATING (BS88) HRC (A)

3 Three Phase

MXZ-8B140VA

MXZ-8B160YA

2-8
16.0
14.0
13.3
13.9
3.91 / 3.52
A/A
100
52 / 47-50
950 x 330 x 1350
129
220-240v, 50Hz
Single
3.90 / 3.79
3.55 / 3.03
14
17.05 / 16.55 [29.5]
4 Core
115
15 (from Branch Box)
70
30 (20 if OU lower than IU)
12
8.5
40

2-8
18.0
15.5
14.95
15.4
3.61 / 3.21
A/A
106
54 / 48-51
950 x 330 x 1350
139
380-415v, 50Hz
Three
4.80 / 4.64
4.37 / 3.71
7
7.00 / 6.77 [13]
4 Core
115
15 (from Branch Box)
70
30 (20 if OU lower than IU)
12
8.5
25

PAC-AK32BC - Branch Box


NUMBER OF CONNECTABLE INDOOR UNITS
POWER SUPPLy TO BRANCH BOX
POWER SUPPLy TO INDOOR UNITS
PIPE SIZE mm (in) Main Outdoor Side - Gas
PIPE SIZE mm (in) Main Outdoor Side - Liquid
MAX PIPE LENGTH - Outdoor Unit to Branch Box (m)
TOTAL PIPE LENGTH - Branch Boxes to Indoor Unit (m)
MAX HEIGHT DIFFERENCE - Outdoor Unit to Branch Box (m)
MAX HEIGHT DIFFERENCE - Branch Box to Indoor Unit (m)
DIMENSIONS (mm) Width x Depth x Height

PAC-AK53BC - Branch Box


NUMBER OF CONNECTABLE INDOOR UNITS
POWER SUPPLy TO BRANCH BOX
POWER SUPPLy TO INDOOR UNITS
PIPE SIZE mm (in) Main Outdoor Side - Gas
PIPE SIZE mm (in) Main Outdoor Side - Liquid
MAX PIPE LENGTH - Outdoor Unit to Branch Box (m)
TOTAL PIPE LENGTH - Branch Boxes to Indoor Unit (m)
MAX HEIGHT DIFFERENCE - Outdoor Unit to Branch Box (m)
MAX HEIGHT DIFFERENCE - Branch Box to Indoor Unit (m)
DIMENSIONS (mm) Width x Depth x Height

PAC-AK32BC
1-3
From Outdoor Unit
From Branch Box
15.88 (5/8)
9.52 (3/8)
55
60
30
15
450 x 280 x 198

PAC-AK53BC
1-5
From Outdoor Unit
From Branch Box
15.88 (5/8)
9.52 (3/8)
55
60
30
15
450 x 280 x 198

Product Dimensions

Outdoor Units

MXZ-8B140VA / 160YA

Upper View

Front View

PAC-SG59SG
Air outlet guides for MXZ-8B140VA, MXZ-8B160yA

Side View

950
322

Handle for moving

Earth terminal

Rear air intake


600

175

19

Branch Boxes

175

Installation Feet

PAC-AK52YP

42

56

Handle for moving

53
28

30

System Control Units

37
56
370
417

330

Power multi for MXZ-8B Connection Pipe

1350

Service panel
Side air intake

635
371

MAC-333IF

MXZ-8B140VA

1079

MXZ-8B160yA

930

23

423

Interface for group control, run fault and connection


to M-NET System

Front piping cover

MAC-397IF

Rear piping cover

PACProduct
Dimensions

MAC-557IF

PAC-AK32BC

Front View

Suspension bolt pitch


320

Side View

Interface for connection to WiFi MELCloud service


450

91
73

205

280

95
79

61

50

39

34

68

402

35

65

198

C
C

70

39

to indoor unit

25

25

to outdoor unit

21

25

Upper View

75

24

75

Suspension bolt pitch

Interface for Contact Terminal and PAR-31MAA /


PAC-yT52CRA Wired Remote Controller

Air discharge

507

Accessories

12

Product Dimensions

PAC-AK53BC
Suspension bolt pitch
320

Front View

Side View
91
73

to indoor unit

95

280
79

50

39

34

39

61
A

35

402

C
C

70

D
D

68

65

198

E
E

25

25

25
75

75

25

25
75

Upper View

21

to outdoor unit
24

75

Suspension bolt pitch

450
55

12

Air Conditioning
1.4.13 1.121

The Flexible & Efficient Multi-Split Range

1.4.14

Multi-Split Combinations
MXZ-2D53VA
1 OUTDOOR UNIT
Indoor Unit
Combination

Indoor Unit
Combination

2 INDOOR UNIT

Unit A
1 ROOM
20
25
35

2.00 / 2.20
2.50 / 3.60
3.50 / 4.00

2 ROOMS
20 + 20
20 + 25
20 + 35
25 + 25
25 + 35
35 + 35

2.00 / 2.20
2.00 / 2.05
1.93 / 2.20
2.50 / 3.15
2.21 / 3.03
2.65 / 3.20

Unit B

2.00 / 2.20
2.50 / 3.35
3.37 / 4.00
2.50 / 3.15
3.09 / 3.37
2.65 / 3.20

MXZ-3D54VA2
1 OUTDOOR UNIT
Indoor Unit
Combination

Unit A

Unit B

Unit C

25 + 25 + 60
25 + 35 + 35
25 + 35 + 50
25 + 35 + 60
25 + 50 + 50
35 + 35 + 35
35 + 35 + 50

1.64 / 2.05
1.89 / 2.67
1.64 / 2.09
1.50 / 2.00
1.44 / 1.72
2.40 / 2.87
2.10 / 2.26

1.64 / 2.05
2.65 / 2.97
2.29 / 2.32
2.10 / 2.22
2.88 / 3.44
2.40 / 2.87
2.10 / 2.26

3.93 / 4.50
2.65 / 2.97
3.27 / 4.18
3.60 / 4.38
2.88 / 3.44
2.40 / 2.87
3.00 / 4.07

4 ROOMS
20 + 20 + 20 + 20
20 + 20 + 20 + 25
20 + 20 + 20 + 35
20 + 20 + 20 + 50
20 + 20 + 25 + 25
20 + 20 + 25 + 35
20 + 20 + 25 + 50
20 + 20 + 35 + 35
20 + 25 + 25 + 25
20 + 25 + 25 + 35
20 + 25 + 25 + 50
20 + 25 + 35 + 35
25 + 25 + 25 + 25
25 + 25 + 25 + 35
25 + 25 + 25 + 50
25 + 25 + 35 + 35

1.80 / 2.15
1.69 / 1.85
1.52 / 1.78
1.31 / 1.37
1.60 / 1.63
1.44 / 1.58
1.25 / 1.24
1.31 / 1.53
1.52 / 1.46
1.37 / 1.41
1.20 / 1.14
1.25 / 1.37
1.80 / 2.15
1.64 / 2.09
1.44 / 1.72
1.50 / 2.04

1.80 / 2.15
1.69 / 1.85
1.52 / 1.78
1.31 / 1.37
1.60 / 1.63
1.44 / 1.58
1.25 / 1.24
1.31 / 1.53
1.89 / 2.38
1.71 / 2.31
1.50 / 1.87
1.57 / 2.24
1.80 / 2.15
1.64 / 2.09
1.44 / 1.72
1.50 / 2.04

1.80 / 2.15
1.69 / 1.85
1.52 / 1.78
1.31 / 1.37
2.00 / 2.67
1.80 / 2.58
1.57 / 2.04
2.29 / 2.77
1.89 / 2.38
1.71 / 2.31
1.50 / 1.87
2.19 / 2.49
1.80 / 2.15
1.64 / 2.09
1.44 / 1.72
2.10 / 2.26

Cooling / Heating Capacity (kW)

UPTO 3 INDOOR UNITS


Cooling / Heating Capacity (kW)
Unit A

Unit B

1 ROOM
20
25
35
50

2.00 / 2.20
2.50 / 3.60
3.50 / 4.00
5.00 / 6.80

2 ROOMS
20 + 20
20 + 25
20 + 35
20 + 50
25 + 25
25 + 35
25 + 50
35 + 35
35 + 50
50 + 50

2.00 / 2.20
2.00 / 2.09
1.96 / 2.02
1.54 / 1.39
2.50 / 3.40
2.25 / 3.22
1.80 / 2.35
2.70 / 3.40
2.22 / 2.52
2.70 / 3.40

2.00 / 2.20
2.50 / 3.41
3.44 / 3.68
3.86 / 4.31
2.50 / 3.40
3.15 / 3.58
3.60 / 4.45
2.70 / 3.40
3.18 / 4.28
2.70 / 3.40

3 ROOMS
20 + 20 +20
20 + 20 + 25
20 + 20 + 35
20 + 20 + 50
20 + 25 + 25
20 + 25 + 35

1.80 / 2.20
1.66 / 1.87
1.44 / 1.78
1.20 / 1.34
1.54 / 1.61
1.35 / 1.55

1.80 / 2.20
1.66 / 1.87
1.44 / 1.78
1.20 + 1.34
1.93 / 2.64
1.69 / 2.53

Unit C

Indoor Unit
Combination

Cooling / Heating Capacity (kW)


Unit D

1.80 / 2.15
2.12 / 3.04
2.65 / 3.25
3.27 / 4.49
2.00 / 2.67
2.52 / 2.87
3.13 / 4.07
2.29 / 2.77
1.89 / 2.38
2.40 / 2.57
3.00 / 3.73
2.19 / 2.49
1.80 / 2.15
2.29 / 2.32
2.88 / 3.44
2.10 / 2.26

MXZ-4D83VA
1 OUTDOOR UNIT
Indoor Unit
Combination

UPTO 4 INDOOR UNITS

Unit A

Unit B

Unit C

Unit D

1.68 / 1.74
1.45 / 1.34
1.33 / 1.27
1.22 / 1.27
1.80 / 1.63
1.62 / 1.58
1.41 / 1.24
1.30 / 1.19
1.19 / 1.19
1.47 / 1.53
1.30 / 1.21
1.20 / 1.16
1.16 / 1.01
1.73 / 1.49
1.56 / 1.44
1.37 / 1.17
1.26 / 1.12
1.43 / 1.40
1.26 / 1.14
1.17 / 1.09
1.31 / 1.36
1.17 / 1.11
2.08 / 2.25
1.89 / 2.19
1.66 / 1.80
1.54 / 1.73
1.73 / 2.13
1.54 / 1.76
1.60 / 2.08
2.08 / 2.25

1.68 / 1.74
1.45 / 1.34
1.33 / 1.27
1.22 / 1.27
1.80 / 1.63
1.62 / 1.58
1.41 / 1.24
1.30 / 1.19
1.19 / 1.19
1.47 / 1.53
1.30 / 1.21
1.20 / 1.16
1.16 / 1.01
2.16 / 2.44
1.95 / 2.36
1.71 / 1.91
1.58 / 1.83
1.78 / 2.30
1.58 / 1.86
1.46 / 1.79
2.30 / 2.48
2.05 / 2.02
2.08 / 2.25
1.89 / 2.19
1.66 / 1.80
1.54 / 1.73
1.73 / 2.13
1.54 / 1.76
2.23 / 2.31
2.08 / 2.25

1.68 / 1.74
1.45 / 1.34
1.33 / 1.27
1.22 / 1.27
2.25 / 2.67
2.03 / 2.58
1.76 / 2.04
1.62 / 1.95
1.49 / 1.95
2.58 / 2.77
2.27 / 2.21
2.10 / 2.11
2.89 / 3.29
2.16 / 2.44
1.95 / 2.36
1.71 / 1.91
1.58 / 1.83
2.50 / 2.55
2.21 / 2.07
2.05 / 1.99
2.30 / 2.48
2.05 / 2.02
2.08 / 2.25
1.89 / 2.19
1.66 / 1.80
1.54 / 1.73
2.42 / 2.37
2.15 / 1.96
2.23 / 2.31
2.08 / 2.25

2.95 / 3.17
3.64 / 4.38
4.00 / 4.58
4.34 / 4.58
2.25 / 2.67
2.84 / 2.87
3.52 / 4.07
3.89 / 4.27
4.23 / 4.27
2.58 / 2.77
3.24 / 3.97
3.60 / 4.17
2.89 / 3.29
2.16 / 2.44
2.73 / 2.63
3.42 / 3.82
3.78 / 4.02
2.50 / 2.55
3.15 / 3.73
3.51 / 3.93
2.30 / 2.48
2.93 / 3.64
2.08 / 2.25
2.64 / 2.43
3.32 / 3.60
3.69 / 3.80
2.42 / 2.37
3.07 / 3.52
2.23 / 2.31
2.08 / 2.25

Cooling / Heating Capacity (kW)


Unit A

1.80 / 2.20
2.08 / 3.06
2.52 / 3.24
3.00 / 4.13
1.93 / 2.64
2.36 / 2.82

20 + 20 + 20 + 35
20 + 20 + 20 + 50
20 + 20 + 20 + 60
20 + 20 + 20 + 71
20 + 20 + 25 + 25
20 + 20 + 25 + 35
20 + 20 + 25 + 50
20 + 20 + 25 + 60
20 + 20 + 25 + 71
20 + 20 + 35 + 35
20 + 20 + 35 + 50
20 + 20 + 35 + 60
20 + 20 + 50 + 50
20 + 25 + 25 + 25
20 + 25 + 25 + 35
20 + 25 + 25 + 50
20 + 25 + 25 + 60
20 + 25 + 35 + 35
20 + 25 + 35 + 50
20 + 25 + 35 + 60
20 + 35 + 35 + 35
20 + 35 + 35 + 50
25 + 25 + 25 + 25
25 + 25 + 25 + 35
25 + 25 + 25 + 50
25 + 25 + 25 + 60
25 + 25 + 35 + 35
25 + 25 + 35 + 50
25 + 35 + 35 + 35
35 + 35 + 35 + 35

Cooling / Heating Capacity (kW)

1 ROOM
20
25
35
50
60
71

2.00 / 2.20
2.50 / 3.60
3.50 / 4.00
5.00 / 7.20
6.00 / 7.90
7.10 / 8.60

2 ROOMS
20 + 20
20 + 25
20 + 35
20 + 50
20 + 60

2.00 / 2.20
2.00 / 2.12
2.00 / 2.20
2.00 / 1.61
1.93 / 1.72

Unit B

Unit C

Unit D

MXZ-5D102VA
1 OUTDOOR UNIT
Indoor Unit
Combination

UPTO 5 INDOOR UNITS


Cooling / Heating Capacity (kW)
Unit A

2.00 / 2.20
2.50 / 3.48
3.50 / 4.00
5.00 / 5.29
5.78 / 6.18

1 ROOM
20
25
35
50
60
71

2.00 / 2.20
2.50 / 3.60
3.50 / 4.00
5.00 / 7.20
6.00 / 7.90
7.10 / 8.60

Unit B

Unit C

Unit D

20 + 25 + 50
20 + 35 + 35
25 + 25 + 25
25 + 25 + 35
25 + 25 + 50
25 + 35 + 35

1.14 / 1.20
1.20 / 1.49
1.80 / 2.33
1.59 / 2.25
1.35 / 1.80
1.42 / 2.17

1.42 / 1.97
2.10 / 2.71
1.80 / 2.33
1.59 / 2.25
1.35 / 1.80
1.99 / 2.41

2.84 / 3.72
2.10 / 2.71
1.80 / 2.33
2.22 / 2.50
2.70 / 3.40
1.99 / 2.41

MXZ-4D72VA
1 OUTDOOR UNIT
Indoor Unit
Combination

UPTO 4 INDOOR UNITS


Cooling / Heating Capacity (kW)
Unit A

Unit B

1 ROOM
20
25
35
50
60

2.00 / 2.20
2.50 / 3.60
3.50 /4.00
5.00 / 7..20
6.00 / 7.90

2 ROOMS
20 + 20
20 + 25
20 + 35
20 + 50
20 + 60
25 + 25
25 + 35
25 + 50
25 + 60
35 + 35
35 + 50
35 + 60
50 + 50
50 + 60
60 + 60

2.00 / 2.20
2.00 / 2.12
2.00 / 2.20
1.94 / 1.76
1.70 / 1.63
2.50 / 3.60
2.50 / 3.60
2.27 / 2.87
2.00 / 2.69
3.40 / 4.00
2.80 / 3.07
2.51 / 2.89
3.40 / 4.30
3.09 / 4.10
3.40 / 4.30

2.00 / 2.20
2.50 / 3.48
3.50 / 4.00
4.86 / 5.74
5.10 / 5.87
2.50 / 3.60
3.50 / 4.0
4.53 / 5.73
4.80 / 5.91
3.40 / 4.00
4.00 / 5.53
4.29 / 5.71
3.40 / 4.30
3.71 / 4.50
3.40 / 4.30

3 ROOMS
20 + 20 +20
20 + 20 + 25
20 + 20 + 35
20 + 20 + 50
20 + 20 + 60
20 + 25 + 25
20 + 25 + 35
20 + 25 + 50
20 + 25 + 60
20 + 35 + 35
20 + 35 + 50
20 + 35 + 60
20 + 50 + 50
25 + 25 + 25
25 + 25 + 35
25 + 25 + 50

2.00 / 2.20
2.00 / 2.04
1.92 / 1.94
1.60 / 1.40
1.44 / 1.32
2.00 / 1.87
1.80 / 1.80
1.52 / 1.35
1.37 / 1.28
1.60 / 1.73
1.37 / 1.31
1.25 / 1.25
1.20 / 1.06
2.40 / 2.87
2.12 / 2.76
1.80 / 2.15

2.00 / 2.20
2.00 / 2.04
1.92 / 1.94
1.60 / 1.40
1.44 / 1.32
2.50 / 3.06
2.25 / 2.94
1.89 / 2.22
1.71 / 2.10
2.80 / 3.14
2.40 / 2.39
2.19 / 2.27
3.00 / 3.47
2.40 / 2.87
2.12 / 2.76
1.80 / 2.15

Air Conditioning
1.4.15 1.121

Unit C

2.00 / 2.20
2.50 / 3.33
3.36 / 3.52
4.00 / 4.59
4.32 / 4.75
2.50 / 3.06
3.15 / 3.27
3.79 / 4.43
4.11 / 4.61
2.80 / 3.14
3.43 / 4.30
3.76 / 4.48
3.00 / 3.47
2.40 / 2.87
2.96 / 3.07
3.60 / 4.30

Unit D

20 + 71
25 + 25
25 + 35
25 + 50
25 + 60
25 + 71
35 + 35
35 + 50
35 + 60
35 + 71
50 + 50
50 + 60
50 + 71
60 + 60
60 + 71

1.71 / 1.81
2.50 / 3.60
2.50 / 3.60
2.50 / 2.83
2.29 / 2.94
2.06 / 2.94
3.50 / 4.00
3.21 / 3.36
2.91 / 3.16
2.61 / 3.16
3.95 / 4.70
3.64 / 4.48
3.31 / 4.48
4.00 / 4.70
3.66 / 4.70

6.09 / 6.49
2.50 / 3.60
3.50 / 4.00
5.00 / 5.67
5.51 / 6.46
5.84 / 6.46
3.50 / 4.00
4.59 / 6.04
4.99 / 6.24
5.29 / 6.24
3.95 / 4.70
4.36 / 4.92
4.69 / 4.92
4.00 / 4.70
4.34 / 4.70

3 ROOMS
20 + 20 +20
20 + 20 + 25
20 + 20 + 35
20 + 20 + 50
20 + 20 + 60
20 + 20 + 71
20 + 25 + 25
20 + 25 + 35
20 + 25 + 50
20 + 25 + 60
20 + 25 + 71
20 + 35 + 35
20 + 35 + 50
20 + 35 + 60
20 + 35 + 71
20 + 50 + 50
20 + 50 + 60
20 + 50 +71
25 + 25 + 25
25 + 25 + 35
25 + 25 + 50
25 + 25 + 60
25 + 25 + 71
25 + 35 + 35
25 + 35 + 50
25 + 35 + 60
25 + 35 + 71
25 + 50 + 50
25 + 50 + 60
35 + 35 + 35
35 + 35 + 50
35 + 35 + 60
35 + 35 + 71
35 + 50 + 50
35 + 50 + 60

2.00 / 2.20
2.00 / 2.01
2.00 / 1.99
1.73 / 1.52
1.58 / 1.43
1.44 / 1.43
2.00 / 1.90
1.90 / 1.91
1.64 / 1.47
1.52 / 1.40
1.38 / 1.40
1.73 / 1.88
1.52 / 1.43
1.39 / 1.36
1.27 / 1.36
1.33 / 1.15
1.23 / 1.11
1.13 / 1.11
2.50 / 3.00
2.26 / 3.02
1.98 / 2.35
1.82 / 2.24
1.65 / 2.24
2.05 / 2.92
1.82 / 2.29
1.67 / 2.18
1.53 / 2.18
1.60 / 1.88
1.48 / 1.81
2.67 / 3.13
2.33 / 2.47
2.15 / 2.36
1.99 / 2.36
2.07 / 2.04
1.93 / 1.97

2.00 / 2.20
2.00 / 2.01
2.00 / 1.99
1.73 / 1.52
1.58 / 1.43
1.44 / 1.43
2.50 / 3.10
2.38 / 3.12
2.05 / 2.41
1.90 / 2.29
1.72 / 2.29
3.03 / 3.41
2.67 / 2.60
2.43 / 2.47
2.22 / 2.47
3.33 / 3.77
3.08 / 3.62
2.84 / 3.62
2.50 / 3.00
2.26 / 3.02
1.98 / 2.35
1.82 / 2.24
1.65 / 2.24
2.87 / 3.24
2.55 / 2.54
2.33 / 2.43
2.14 / 2.43
3.20 / 3.76
2.96 / 3.62
2.67 / 3.13
2.33 / 2.47
2.15 / 2.36
1.99 / 2.36
2.96 / 3.68
2.76 / 3.54

2.00 / 2.20
2.50 / 3.29
3.50 / 3.62
4.33 / 4.97
4.74 / 5.14
5.12 / 5.14
2.50 / 3.10
3.33 / 3.47
4.11 / 4.82
4.57 / 5.02
4.90 / 5.02
3.03 / 3.41
3.81 / 4.67
4.17 / 4.87
4.51 / 4.87
3.33 / 3.77
3.69 / 3.97
4.03 / 3.97
2.50 / 3.00
3.17 / 3.36
3.95 / 4.70
4.36 / 4.92
4.69 / 4.92
2.87 / 3.24
3.64 / 4.57
4.00 / 4.79
4.34 / 4.79
3.20 / 3.76
3.56 / 3.97
2.67 / 3.13
3.33 / 4.45
3.69 / 4.67
4.03 / 4.67
2.96 / 3.68
3.31 / 3.89

4 ROOMS
20 + 20 + 20 + 20
20 + 20 + 20 + 25

1.90 / 2.05
1.88 / 1.81

1.90 / 2.05
1.88 / 1.81

1.90 / 2.05
1.88 / 1.81

1.90 / 2.05
2.35 / 2.96

2 ROOMS
20 + 20
20 + 25
20 + 35
20 + 50
20 + 60
20 + 71
25 + 25
25 + 35
25 + 50
25 + 60
25 + 71
35 + 35
35 + 50
35 + 60
35 + 71
50 + 50
50 + 60
50 + 71
60 + 60
60 + 71
71 + 71

2.00 / 2.20
2.00 / 2.12
2.00 / 2.20
2.00 / 1.61
1.90 / 1.90
1.76 / 2.05
2.50 / 3.60
2.50 / 3.60
2.43 / 2.97
2.29 / 3.29
2.14 / 3.29
3.50 / 4.00
3.21 / 3.75
2.98 / 3.53
2.81 / 3.53
4.15 / 5.25
3.91 / 5.01
3.68 / 5.01
4.45 / 5.25
4.12 / 5.25
4.55 / 5.25

2.00 / 2.20
2.50 / 3.48
3.50 / 4.00
5.00 / 5.29
5.70 / 6.80
6.24 / 7.35
2.50 / 3.60
3.50 / 4.00
4.87 / 5.93
5.51 / 7.21
6.06 / 7.21
3.50 / 4.00
4.59 / 6.75
5.12 / 6.97
5.69 / 6.97
4.15 / 5.25
4.69 / 5.49
5.22 / 5.49
4.45 / 5.25
4.88 / 5.25
4.55 / 5.25

3 ROOMS
20 + 20 +20
20 + 20 + 25
20 + 20 + 35
20 + 20 + 50
20 + 20 + 60
20 + 20 + 71
20 + 25 + 25
20 + 25 + 35
20 + 25 + 50
20 + 25 + 60
20 + 25 + 71
20 + 35 + 35
20 + 35 + 50
20 + 35 + 60
20 + 35 + 71
20 + 50 + 50
20 + 50 + 60
20 + 50 +71
20 + 60 + 60
20 + 60 + 71
25 + 25 + 25
25 + 25 + 35
25 + 25 + 50
25 + 25 + 60
25 + 25 + 71
25 + 35 + 35
25 + 35 + 50
25 + 35 + 60
25 + 35 + 71
25 + 50 + 50
25 + 50 + 60
25 + 50 + 71

2.00 / 2.20
2.00 / 2.01
2.00 / 1.99
1.80 / 1.54
1.68 / 1.50
1.57 / 1.56
2.00 / 1.90
1.93 / 1.91
1.73 / 1.52
1.64 / 1.49
1.52 / 1.54
1.80 / 1.90
1.64 / 1.53
1.53 / 1.48
1.43 / 1.53
1.48 / 1.29
1.40 / 1.25
1.32 / 1.25
1.31 / 1.20
1.25 / 1.20
2.50 / 3.00
2.32 / 2.99
2.10 / 2.45
1.98 / 2.41
1.84 / 2.48
2.16 / 3.01
1.98 / 2.46
1.85 / 2.42
1.74 / 2.44
1.80 / 2.10
1.70 / 2.02
1.59 / 2.02

2.00 / 2.20
2.00 / 2.01
2.00 / 1.99
1.80 / 1.54
1.68 / 1.50
1.57 / 1.56
2.50 / 3.10
2.41 / 3.12
2.16 / 2.49
2.05 / 2.44
1.90 / 2.52
3.15 / 3.45
2.87 / 2.78
2.68 / 2.70
2.50 / 2.78
3.71 / 4.21
3.50 / 4.08
3.30 / 4.08
3.94 / 4.30
3.74 / 4.30
2.50 / 3.00
2.32 / 2.99
2.10 / 2.45
1.98 / 2.41
1.84 / 2.48
3.02 / 3.34
2.77 / 2.73
2.60 / 2.68
2.43 / 2.71
3.60 / 4.20
3.41 / 4.04
3.18 / 4.04

2.00 / 2.20
2.50 / 3.29
3.50 / 3.62
4.50 / 5.03
5.04 / 5.40
5.56 / 5.59
2.50 / 3.10
3.37 / 3.47
4.32 / 4.98
4.91 / 5.36
5.39 / 5.54
3.15 / 3.45
4.10 / 5.00
4.59 / 5.32
5.07 / 5.49
3.71 / 4.21
4.20 / 4.48
4.68 / 4.48
3.94 / 4.30
4.42 / 4.30
2.50 / 3.00
3.25 / 3.32
4.20 / 4.90
4.75 / 5.28
5.22 / 5.44
3.02 / 3.34
3.95 / 4.91
4.45 / 5.30
4.93 / 5.35
3.60 / 4.20
4.09 / 4.44
4.52 / 4.44

The Flexible & Efficient Multi-Split Range

1.4.16

Multi-Split Combinations
MXZ-5D102VA
1 OUTDOOR UNIT
Indoor Unit
Combination

Indoor Unit
Combination

UPTO 5 INDOOR UNITS

Cooling / Heating Capacity (kW)

Cooling / Heating Capacity (kW)

3 ROOMS
25 + 60 + 60
25 + 60 + 71
35 + 35 + 35
35 + 35 + 50
35 + 35 + 60
35 + 35 + 71
35 + 50 + 50
35 + 50 + 60
35 + 50 + 71
35 + 60 + 60
35 + 60 + 71
50 + 50 + 50
50 + 50 + 60
50 + 50 + 71

Unit A

Unit B

Unit C

1.60 / 1.95
1.51 / 1.95
2.87 / 3.33
2.60 / 2.74
2.45 / 2.64
2.31 / 2.64
2.39 / 2.28
2.24 / 2.20
2.11 / 2.20
2.12 / 2.12
1.98 / 2.12
3.13 / 3.50
2.94 / 3.39
2.75 / 3.39

3.85 / 4.28
3.62 / 4.28
2.87 / 3.33
2.60 / 2.74
2.45 / 2.64
2.31 / 2.64
3.41 / 4.11
3.21 / 3.96
3.01 / 3.96
3.64 / 4.19
3.40 / 4.19
3.13 / 3.50
2.94 / 3.39
2.75 / 3.39

3.85 / 4.28
4.28 / 4.28
2.87 / 3.33
3.71 / 4.93
4.20 / 5.22
4.68 / 5.22
3.41 / 4.11
3.85 / 4.34
4.28 / 4.34
3.64 / 4.19
4.02 / 4.19
3.13 / 3.50
3.53 / 3.72
3.90 / 3.72

4 ROOMS
20 + 20 + 20 + 20
20 + 20 + 20 + 25
20 + 20 + 20 + 35
20 + 20 + 20 + 50
20 + 20 + 20 + 60
20 + 20 + 20 + 71
20 + 20 + 25 + 25
20 + 20 + 25 + 35
20 + 20 + 25 + 50
20 + 20 + 25 + 60
20 + 20 + 25 + 71
20 + 20 + 35 + 35
20 + 20 + 35 + 50
20 + 20 + 35 + 60
20 + 20 + 35 + 71
20 + 20 + 50 + 50
20 + 20 + 50 + 60
20 + 20 + 50 + 71
20 + 25 + 25 + 25
20 + 25 + 25 + 35
20 + 25 + 25 + 50
20 + 25 + 25 + 60
20 + 25 + 25 + 71
20 + 25 + 35 + 35
20 + 25 + 35 + 50
20 + 25 + 35 + 60
20 + 25 + 35 + 71
20 + 25 + 50 + 50
20 + 25 + 50 + 60

1.90 / 2.20
1.93 / 1.96
1.77 / 1.89
1.55 / 1.47
1.45 / 1.43
1.36 / 1.44
1.91 / 1.78
1.68 / 1.72
1.51 / 1.39
1.42 / 1.34
1.34 / 1.37
1.56 / 1.69
1.42 / 1.37
1.35 / 1.32
1.26 / 1.34
1.31 / 1.16
1.23 / 1.12
1.14 / 1.12
1.81 / 1.64
1.64 / 1.61
1.48 / 1.33
1.40 / 1.28
1.32 / 1.30
1.53 / 1.58
1.40 / 1.31
1.33 / 1.27
1.23 / 1.27
1.28 / 1.11
1.20 / 1.07

1.90 / 2.20
1.93 / 1.96
1.77 / 1.89
1.55 / 1.47
1.45 / 1.43
1.36 / 1.44
1.91 / 1.78
1.68 / 1.72
1.51 / 1.39
1.42 / 1.34
1.34 / 1.37
1.56 / 1.69
1.42 / 1.37
1.35 / 1.32
1.26 / 1.34
1.31 / 1.16
1.23 / 1.12
1.14 / 1.12
2.26 / 2.69
2.05 / 2.63
1.85 / 2.17
1.75 / 2.10
1.65 / 2.12
1.91 / 2.58
1.75 / 2.14
1.66 / 2.07
1.54 / 2.07
1.60 / 1.82
1.50 / 1.76

1.90 / 2.20
1.93 / 2.41
1.77 / 1.89
1.55 / 1.47
1.45 / 1.43
1.36 / 1.44
2.39 / 2.92
2.10 / 2.82
1.89 / 2.27
1.78 / 2.20
1.67 / 2.24
2.74 / 3.06
2.49 / 2.49
2.36 / 2.40
2.21 / 2.43
3.29 / 3.79
3.07 / 3.66
2.86 / 3.66
2.26 / 2.69
2.05 / 2.63
1.85 / 2.17
1.75 / 2.10
1.65 / 2.12
2.68 / 2.87
2.45 / 2.38
2.33 / 2.31
2.16 / 2.31
3.21 / 3.64
3.00 / 3.51

Unit D

1.90 / 2.20
2.12 / 3.21
3.09 / 3.43
3.86 / 4.80
4.35 / 5.12
4.82 / 5.18
2.39 / 2.92
2.94 / 3.13
3.78 / 4.55
4.27 / 4.82
4.75 / 4.92
2.74 / 3.06
3.56 / 4.48
4.04 / 4.75
4.47 / 4.80
3.29 / 3.79
3.68 / 4.01
4.06 / 4.01
2.26 / 2.69
2.87 / 2.93
3.71 / 4.34
4.20 / 4.61
4.68 / 4.66
2.68 / 2.87
3.50 / 4.28
3.99 / 4.55
4.37 / 4.55
3.21 / 3.64
3.60 / 3.86

Unit E

20 + 25 + 25 + 25 + 60
20 + 25 + 25 + 25 + 71
20 + 25 + 25 + 35 + 35
20 + 25 + 25 + 35 + 50
20 + 25 + 25 + 35 + 60
20 + 25 + 35 + 35 + 35
20 + 25 + 35 + 35 + 50
20 + 35 + 35 + 35 + 35
25 + 25 + 25 + 25 + 25
25 + 25 + 25 + 25 + 35
25 + 25 + 25 + 25 + 50
25 + 25 + 25 + 25 + 60
25 + 25 + 25 + 25 + 71
25 + 25 + 25 + 35 + 35
25 + 25 + 25 + 35 + 50
25 + 25 + 25 + 35 + 60
25 + 25 + 35 + 35 + 35
25 + 25 + 35 + 35 + 50

Unit A

Unit B

Unit C

Unit D

Unit E

1.30 / 1.09
1.22 / 1.09
1.44 / 1.31
1.30 / 1.11
1.22 / 1.07
1.35 / 1.29
1.22 / 1.09
1.26 / 1.26
2.04 / 2.10
1.89 / 2.05
1.70 / 1.75
1.59 / 1.70
1.49 / 1.70
1.76 / 2.01
1.59 / 1.72
1.50 / 1.67
1.65 / 1.97
1.50 / 1.69

1.63 / 1.79
1.52 / 1.79
1.80 / 2.15
1.63 / 1.82
1.53 / 1.76
1.68 / 2.10
1.53 / 1.78
2.21 / 2.29
2.04 / 2.10
1.89 / 2.05
1.70 / 1.75
1.59 / 1.70
1.49 / 1.70
1.76 / 2.01
1.59 / 1.72
1.50 / 1.67
1.65 / 1.97
1.50 / 1.69

1.63 / 1.79
1.52 / 1.79
1.80 / 2.15
1.63 / 1.82
1.53 / 1.76
2.36 / 2.34
2.14 / 1.98
2.21 / 2.29
2.04 / 2.10
1.89 / 2.05
1.70 / 1.75
1.59 / 1.70
1.49 / 1.70
1.76 / 2.01
1.59 / 1.72
1.50 / 1.67
2.30 / 2.19
2.10 / 1.88

1.63 / 1.79
1.52 / 1.79
2.53 / 2.39
2.28 / 2.02
2.14 / 1.95
2.36 / 2.34
2.14 / 1.98
2.21 / 2.29
2.04 / 2.10
1.89 / 2.05
1.70 / 1.75
1.59 / 1.70
1.49 / 1.70
2.46 / 2.23
2.23 / 1.91
2.10 / 1.85
2.30 / 2.19
2.10 / 1.88

3.91 / 3.93
4.32 / 3.93
2.53 / 2.39
3.26 / 3.63
3.67 / 3.86
2.36 / 2.34
3.06 / 3.57
2.21 / 2.29
2.04 / 2.10
2.64 / 2.28
3.40 / 3.50
3.83 / 3.72
4.24 / 3.72
2.46 / 2.23
3.19 / 3.44
3.60 / 3.65
2.30 / 2.19
3.00 / 3.38

MXZ-6C122VA
1 OUTDOOR UNIT
Indoor Unit
Combination

UPTO 6 INDOOR UNITS


Cooling / Heating Capacity (kW)
Unit A

1 ROOM
20
25
35
50
60
71

2.00 / 2.20
2.50 / 3.60
3.50 / 4.00
5.00 / 7.20
6.00 / 7.90
7.10 / 8.60

2 ROOMS
20 + 20
20 + 25
20 + 35
20 + 50
20 + 60
20 + 71
25 + 25
25 + 35
25 + 50
25 + 60
25 + 71
35 + 35

2.00 / 2.20
2.00 / 2.58
2.00 / 2.25
2.00 / 2.69
2.00 / 2.53
1.89 / 2.46
2.50 / 3.60
2.50 / 3.33
2.50 / 3.73
2.47 / 3.32
2.29 / 2.94
3.50 / 4.00

Unit B

2.00 / 2.20
2.50 / 3.22
3.50 / 3.95
5.00 / 6.71
6.00 / 7.58
6.71 / 8.74
2.50 / 3.60
3.50 / 4.67
5.00 / 7.47
5.93 / 7.98
6.51 / 8.36
3.50 / 4.00

Unit C

Unit D

Unit E

Unit F

20 + 25 + 50 + 71
20 + 35 + 35 + 35
20 + 35 + 35 + 50
20 + 35 + 35 + 60
20 + 35 + 35 + 71
20 + 35 + 50 + 50
20 + 35 + 50 + 60
25 + 25 + 25 + 25
25 + 25 + 25 + 35
25 + 25 + 25 + 50
25 + 25 + 25 + 60
25 + 25 + 25 + 71
25 + 25 + 35 + 35
25 + 25 + 35 + 50
25 + 25 + 35 + 60
25 + 25 + 35 + 71
25 + 25 + 50 + 50
25 + 25 + 50 + 60
25 + 25 + 50 + 71
25 + 35 + 35 + 35
25 + 35 + 35 + 50
25 + 35 + 35 + 60
25 + 35 + 35 + 71
35 + 35 + 35 + 35
35 + 35 + 35 + 50
35 + 35 + 35 + 60

1.12 / 1.07
1.44 / 1.55
1.33 / 1.29
1.24 / 1.24
1.16 / 1.24
1.20 / 1.09
1.13 / 1.05
2.15 / 2.50
2.00 / 2.46
1.82 / 2.06
1.72 / 2.00
1.61 / 2.02
1.88 / 2.44
1.72 / 2.03
1.62 / 1.98
1.51 / 1.98
1.57 / 1.75
1.47 / 1.70
1.37 / 1.70
1.77 / 2.40
1.62 / 2.01
1.52 / 1.94
1.42 / 1.94
2.35 / 2.63
2.12 / 2.19
1.99 / 2.11

1.40 / 1.76
2.52 / 2.82
2.33 / 2.34
2.17 / 2.25
2.02 / 2.25
2.10 / 1.98
1.97 / 1.92
2.15 / 2.50
2.00 / 2.46
1.82 / 2.06
1.72 / 2.00
1.61 / 2.02
1.88 / 2.44
1.72 / 2.03
1.62 / 1.98
1.51 / 1.98
1.57 / 1.75
1.47 / 1.70
1.37 / 1.70
2.48 / 2.67
2.27 / 2.23
2.12 / 2.15
1.98 / 2.15
2.35 / 2.63
2.12 / 2.19
1.99 / 2.11

2.80 / 3.51
2.52 / 2.82
2.33 / 2.34
2.17 / 2.25
2.02 / 2.25
3.00 / 3.57
2.82 / 3.45
2.15 / 2.50
2.00 / 2.46
1.82 / 2.06
1.72 / 2.00
1.61 / 2.02
2.63 / 2.71
2.41 / 2.26
2.27 / 2.20
2.11 / 2.20
3.13 / 3.50
2.94 / 3.39
2.75 / 3.39
2.48 / 2.67
2.27 / 2.23
2.12 / 2.15
1.98 / 2.15
2.35 / 2.63
2.12 / 2.19
1.99 / 2.11

3.98 / 3.86
2.52 / 2.82
3.32 / 4.22
3.72 / 4.45
4.10 / 4.45
3.00 / 3.57
3.38 / 3.78
2.15 / 2.50
2.80 / 2.73
3.64 / 4.12
4.13 / 4.39
4.57 / 4.44
2.63 / 2.71
3.44 / 4.07
3.89 / 4.34
4.28 / 4.34
3.13 / 3.50
3.53 / 3.72
3.90 / 3.72
2.48 / 2.67
3.24 / 4.02
3.64 / 4.25
4.02 / 4.25
2.35 / 2.63
3.03 / 3.94
3.42 / 4.17

5 ROOMS
20 + 20 + 20 + 20 + 20
20 + 20 + 20 + 20 + 25
20 + 20 + 20 + 20 + 35
20 + 20 + 20 + 20 + 50
20 + 20 + 20 + 20 + 60
20 + 20 + 20 + 20 + 71
20 + 20 + 20 + 25 + 25
20 + 20 + 20 + 25 + 35
20 + 20 + 20 + 25 + 50
20 + 20 + 20 + 25 + 60
20 + 20 + 20 + 25 + 71
20 + 20 + 20 + 35 + 35
20 + 20 + 20 + 35 + 50
20 + 20 + 20 + 35 + 60
20 + 20 + 20 + 35 + 71
20 + 20 + 25 + 25 + 25
20 + 20 + 25 + 25 + 35
20 + 20 + 25 + 25 + 50
20 + 20 + 25 + 25 + 60
20 + 20 + 25 + 25 + 71
20 + 20 + 25 + 35 + 35
20 + 20 + 25 + 35 + 50
20 + 20 + 25 + 35 + 60
20 + 20 + 35 + 35 + 35
20 + 20 + 35 + 35 + 50
20 + 25 + 25 + 25 + 25
20 + 25 + 25 + 25 + 35
20 + 25 + 25 + 25 + 50

1.90 / 2.00
1.87 / 1.79
1.70 / 1.74
1.51 / 1.39
1.40 / 1.33
1.30 / 1.33
1.80 / 1.63
1.65 / 1.58
1.47 / 1.29
1.37 / 1.24
1.27 / 1.24
1.52 / 1.54
1.37 / 1.26
1.28 / 1.21
1.19 / 1.21
1.74 / 1.49
1.60 / 1.45
1.43 / 1.21
1.33 / 1.16
1.24 / 1.16
1.48 / 1.42
1.33 / 1.18
1.25 / 1.14
1.38 / 1.38
1.25 / 1.16
1.68 / 1.38
1.55 / 1.35
1.39 / 1.13

1.90 / 2.00
1.87 / 1.79
1.70 / 1.74
1.51 / 1.39
1.40 / 1.33
1.30 / 1.33
1.80 / 1.63
1.65 / 1.58
1.47 / 1.29
1.37 / 1.24
1.27 / 1.24
1.52 / 1.54
1.37 / 1.26
1.28 / 1.21
1.19 / 1.21
1.74 / 1.49
1.60 / 1.45
1.43 / 1.21
1.33 / 1.16
1.24 / 1.16
1.48 / 1.42
1.33 / 1.18
1.25 / 1.14
1.38 / 1.38
1.25 / 1.16
2.10 / 2.26
1.94 / 2.20
1.74 / 1.85

1.90 / 2.00
1.87 / 1.79
1.70 / 1.74
1.51 / 1.39
1.40 / 1.33
1.30 / 1.33
1.80 / 1.63
1.65 / 1.58
1.47 / 1.29
1.37 / 1.24
1.27 / 1.24
1.52 / 1.54
1.37 / 1.26
1.28 / 1.21
1.19 / 1.21
2.17 / 2.44
2.00 / 2.38
1.79 / 1.97
1.67 / 1.90
1.55 / 1.90
1.85 / 2.32
1.67 / 1.93
1.56 / 1.86
2.41 / 2.51
2.19 / 2.10
2.10 / 2.26
1.94 / 2.20
1.74 / 1.85

1.90 / 2.00
1.87 / 1.79
1.70 / 1.74
1.51 / 1.39
1.40 / 1.33
1.30 / 1.33
2.25 / 2.66
2.06 / 2.59
1.83 / 2.11
1.71 / 2.03
1.59 / 2.03
2.67 / 2.79
2.39 / 2.29
2.24 / 2.21
2.09 / 2.21
2.17 / 2.44
2.00 / 2.38
1.79 / 1.97
1.67 / 1.90
1.55 / 1.90
2.59 / 2.58
2.33 / 2.15
2.19 / 2.07
2.41 / 2.51
2.19 / 2.10
2.10 / 2.26
1.94 / 2.20
1.74 / 1.85

Air Conditioning
1.4.17 1.121

1.90 / 2.00
2.33 / 2.93
2.98 / 3.16
3.77 / 4.55
4.20 / 4.78
4.61 / 4.78
2.25 / 2.66
2.89 / 2.87
3.67 / 4.22
4.10 / 4.45
4.51 / 4.45
2.67 / 2.79
3.41 / 4.13
3.83 / 4.36
4.23 / 4.36
2.17 / 2.44
2.80 / 2.64
3.57 / 3.94
4.00 / 4.17
4.41 / 4.17
2.59 / 2.58
3.33 / 3.86
3.75 / 4.09
2.41 / 2.51
3.13 / 3.78
2.10 / 2.26
2.72 / 2.45
3.48 / 3.71

35 + 50
35 + 60
35 + 71
50 + 50
50 + 60
50 + 71
60 + 60
60 + 71
71 + 71

3.46 / 4.65
3.21 / 4.16
3.00 / 3.73
4.45 / 5.65
4.23 / 5.14
3.97 / 4.67
4.80 / 5.65
4.44 / 5.18
4.85 / 5.65

4.94 / 6.65
5.49 / 7.14
6.10 / 7.57
4.45 / 5.65
5.07 / 6.16
5.63 / 6.63
4.80 / 5.65
5.26 / 6.12
4.85 / 5.65

3 ROOMS
20 + 20 +20
20 + 20 + 25
20 + 20 + 35
20 + 20 + 50
20 + 20 + 60
20 + 20 + 71
20 + 25 + 25
20 + 25 + 35
20 + 25 + 50
20 + 25 + 60
20 + 25 + 71
20 + 35 + 35
20 + 35 + 50
20 + 35 + 60
20 + 35 + 71
20 + 50 + 50
20 + 50 + 60
20 + 50 +71
20 + 60 + 60
20 + 60 + 71
20 + 71 + 71
25 + 25 + 25
25 + 25 + 35
25 + 25 + 50
25 + 25 + 60
25 + 25 + 71
25 + 35 + 35
25 + 35 + 50
25 + 35 + 60
25 + 35 + 71
25 + 50 + 50
25 + 50 + 60
25 + 50 + 71
25 + 60 + 60
25 + 60 + 71
25 + 71 + 71
35 + 35 + 35
35 + 35 + 50
35 + 35 + 60
35 + 35 + 71
35 + 50 + 50
35 + 50 + 60
35 + 50 + 71
35 + 60 + 60
35 + 60 + 71

2.00 / 2.20
2.00 / 2.46
2.00 / 2.24
1.98 / 2.58
1.92 / 2.42
1.75 / 2.20
2.00 / 2.69
2.05 / 2.45
1.87 / 2.57
1.83 / 2.34
1.69 / 2.17
1.98 / 2.27
1.83 / 2.34
1.69 / 2.17
1.57 / 2.02
1.63 / 2.17
1.54 / 2.02
1.46 / 1.87
1.47 / 1.89
1.40 / 1.76
1.36 / 1.67
2.50 / 3.60
2.41 / 3.29
2.40 / 3.15
2.20 / 2.90
2.02 / 2.64
2.34 / 3.05
2.20 / 2.89
2.04 / 2.67
1.91 / 2.47
1.98 / 2.64
1.89 / 2.46
1.80 / 2.31
1.81 / 2.33
1.73 / 2.17
1.66 / 2.04
3.20 / 4.00
2.86 / 3.73
2.69 / 3.47
2.56 / 3.23
2.64 / 3.45
2.53 / 3.23
2.42 / 3.03
2.44 / 3.05
2.34 / 2.87

2.00 / 2.20
2.00 / 2.46
2.00 / 2.24
1.98 / 2.58
1.92 / 2.42
1.75 / 2.20
2.50 / 3.36
2.56 / 3.06
2.34 / 3.21
2.29 / 2.93
2.11 / 2.72
3.46 / 3.97
3.20 / 4.10
2.95 / 3.80
2.75 / 3.53
4.08 / 5.42
3.85 / 5.04
3.65 / 4.68
4.41 / 5.66
4.21 / 5.28
4.82 / 5.92
2.50 / 3.60
2.41 / 3.29
2.40 / 3.15
2.20 / 2.90
2.02 / 2.64
3.28 / 4.27
3.09 / 4.04
2.86 / 3.73
2.67 / 3.46
3.96 / 5.28
3.78 / 4.93
3.60 / 4.62
4.34 / 5.59
4.15 / 5.21
4.72 / 5.78
3.20 / 4.00
2.86 / 3.73
2.69 / 3.47
2.56 / 3.23
3.78 / 4.93
3.62 / 4.62
3.46 / 4.33
4.18 / 5.23
4.01 / 4.92

2.00 / 2.20
2.50 / 3.08
3.50 / 3.92
4.94 / 6.44
5.76 / 7.26
6.20 / 7.80
2.50 / 3.36
3.59 / 4.29
4.68 / 6.42
5.49 / 7.03
6.00 / 7.71
3.46 / 3.97
4.57 / 5.86
5.06 / 6.52
5.58 / 7.16
4.08 / 5.42
4.62 / 6.05
5.19 / 6.65
4.41 / 5.66
4.98 / 6.25
4.82 / 5.92
2.50 / 3.60
3.38 / 4.61
4.80 / 6.30
5.29 / 6.97
5.75 / 7.51
3.28 / 4.27
4..41 / 5.77
4.90 / 6.40
5.42 / 7.03
3.96 / 5.28
4.53 / 5.91
5.11 / 6.57
4.34 / 5.59
4.92 / 6.16
4.72 / 5.78
3.20 / 4.00
4.08 / 5.33
4.62 / 5.95
5.19 / 6.55
3.78 / 4.93
4.34 / 5.54
4.92 / 6.14
4.18 / 5.23
4.75 / 5.82

The Flexible & Efficient Multi-Split Range

1.4.18

Multi-Split Combinations
MXZ-6C122VA
1 OUTDOOR UNIT
Indoor Unit
Combination

Indoor Unit
Combination

UPTO 6 INDOOR UNITS

Unit A

Unit B

Unit C

20 + 20 + 25 + 25 + 71
20 + 20 + 25 + 35 + 35
20 + 20 + 25 + 35 + 50
20 + 20 + 25 + 35 + 60
20 + 20 + 25 + 35 + 71
20 + 20 + 25 + 50 + 50
20 + 20 + 35 + 35 + 35
20 + 20 + 35 + 35 + 50
20 + 20 + 35 + 35 + 60
20 + 20 + 35 + 50 + 50
20 + 25 + 25 + 25 + 25
20 + 25 + 25 + 25 + 35
20 + 25 + 25 + 25 + 50
20 + 25 + 25 + 25 + 60
20 + 25 + 25 + 25 + 71
20 + 25 + 25 + 35 + 35
20 + 25 + 25 + 35 + 50
20 + 25 + 25 + 35 + 60
20 + 25 + 25 + 35 + 71
20 + 25 + 25 + 50 + 50
20 + 25 + 35 + 35 + 35
20 + 25 + 35 + 35 + 50
20 + 25 + 35 + 35 + 60
20 + 35 + 35 + 35 + 35
20 + 35 + 35 + 35 + 50
25 + 25 + 25 + 25 + 25
25 + 25 + 25 + 25 + 35
25 + 25 + 25 + 25 + 50
25 + 25 + 25 + 25 + 60
25 + 25 + 25 + 25 + 71
25 + 25 + 25 + 35 + 35
25 + 25 + 25 + 35 + 50
25 + 25 + 25 + 35 + 60
25 + 25 + 25 + 50 + 50
25 + 25 + 35 + 35 + 35
25 + 25 + 35 + 35 + 50
25 + 25 + 35 + 35 + 60
25 + 35 + 35 + 35 + 35
25 + 35 + 35 + 35 + 50
35 + 35 + 35 + 35 + 35

1.50 / 1.66
1.78 / 1.99
1.61 / 1.79
1.51 / 1.68
1.43 / 1.57
1.47 / 1.62
1.66 / 1.85
1.51 / 1.68
1.44 / 1.58
1.39 / 1.53
1.93 / 2.23
1.83 / 2.06
1.66 / 1.85
1.56 / 1.73
1.46 / 1.61
1.71 / 1.91
1.56 / 1.73
1.47 / 1.62
1.39 / 1.52
1.44 / 1.58
1.61 / 1.79
1.47 / 1.62
1.39 / 1.53
1.51 / 1.68
1.39 / 1.53
2.38 / 2.68
2.22 / 2.48
2.02 / 2.23
1.89 / 2.09
1.78 / 1.96
2.07 / 2.31
1.89 / 2.09
1.79 / 1.97
1.74 / 1.91
1.95 2.16
1.79 / 1.97
1.69 / 1.86
1.83 / 2.03
1.69 / 1.86
2.44 / 2.68

1.50 / 1.66
1.78 / 1.99
1.61 / 1.79
1.51 / 1.68
1.43 / 1.57
1.47 / 1.62
1.66 / 1.85
1.51 / 1.68
1.44 / 1.58
1.39 / 1.53
2.42 / 2.79
2.29 / 2.58
2.07 / 2.31
1.95 / 2.16
1.82 / 2.02
2.14 / 2.39
1.95 / 2.16
1.83 / 2.03
1.73 / 1.90
1.79 / 1.97
2.02 / 2.23
1.83 / 2.03
1.74 / 1.91
2.65 / 2.93
2.44 / 2.68
2.38 / 2.68
2.22 / 2.48
2.02 / 2.23
1.89 / 2.09
1.78 / 1.96
2.07 / 2.31
1.89 / 2.09
1.79 / 1.97
1.74 / 1.91
1.95 2.16
1.79 / 1.97
1.69 / 1.86
2.57 / 2.84
2.37 / 2.61
2.44 / 2.68

1.88 / 2.08
2.22 / 2.48
2.02 / 2.23
1.89 / 2.09
1.78 / 1.96
1.83 / 2.03
2.90 / 3.23
2.65 / 2.93
2.51 / 2.76
2.44 / 2.68
2.42 / 2.79
2.29 / 2.58
2.07 / 2.31
1.95 / 2.16
1.82 / 2.02
2.14 / 2.39
1.95 / 2.16
1.83 / 2.03
1.73 / 1.90
1.79 / 1.97
2.82 / 3.13
2.57 / 2.84
2.44 / 2.68
2.65 / 2.93
2.44 / 2.68
2.38 / 2.68
2.22 / 2.48
2.02 / 2.23
1.89 / 2.09
1.78 / 1.96
2.07 / 2.31
1.89 / 2.09
1.79 / 1.97
1.74 / 1.91
2.73 / 3.03
2.51 / 2.76
2.37 / 2.61
2.57 / 2.84
2.37 / 2.61
2.44 / 2.68

1.88 / 2.08
3.11 / 3.47
2.82 / 3.13
2.65 / 2.93
2.50 / 2.74
3.67 / 4.06
2.90 / 3.23
2.65 / 2.93
2.51 / 2.76
3.49 / 3.83
2.42 / 2.79
2.29 / 2.58
2.07 / 2.31
1.95 / 2.16
1.82 / 2.02
3.00 / 3.35
2.73 / 3.03
2.57 / 2.84
2.43 / 2.66
3.59 / 3.94
2.82 / 3.13
2.57 / 2.84
2.44 / 2.68
2.65 / 2.93
2.44 / 2.68
2.38 / 2.68
2.22 / 2.48
2.02 / 2.23
1.89 / 2.09
1.78 / 1.96
2.90 / 3.23
2.65 / 2.93
2.51 / 2.76
3.49 / 3.83
2.73 / 3.03
2.51 / 2.76
2.37 / 2.61
2.57 / 2.84
2.37 / 2.61
2.44 / 2.68

5.34 / 5.91
3.11 / 3.47
4.03 / 4.47
4.54 / 5.03
5.07 / 5.56
3.67 / 4.06
2.90 / 3.23
3.78 / 4.19
4.31 / 4.73
3.49 / 3.83
2.42 / 2.79
3.20 / 3.61
4.14 / 4.62
4.68 / 5.19
5.18 / 5.73
3.00 / 3.35
3.9 / 4.32
4.40 / 4.87
4.92 / 5.41
3.59 / 3.94
2.82 / 3.13
3.67 / 4.06
4.18 / 4.59
2.65 / 2.93
3.49 / 3.83
2.38 / 2.68
3.11 / 3.47
4.03 / 4.47
4.54 / 5.03
5.07 / 5.56
2.90 / 3.23
3.78 / 4.19
4.31 / 4.73
3.49 / 3.83
2.73 / 3.03
3.59 / 3.94
4.07 / 4.47
2.57 / 2.84
3.39 / 3.72
2.44 / 2.68

6 ROOMS
20 + 20 + 20 + 20 + 20 + 20
20 + 20 + 20 + 20 + 20 + 25
20 + 20 + 20 + 20 + 20 + 35
20 + 20 + 20 + 20 + 20 + 50
20 + 20 + 20 + 20 + 20 + 60

1.90 / 2.12
1.87 / 2.19
1.79 / 2.06
1.63 / 1.87
1.53 / 1.75

1.90 / 2.12
1.87 / 2.19
1.79 / 2.06
1.63 / 1.87
1.53 / 1.75

1.90 / 2.12
1.87 / 2.19
1.79 / 2.06
1.63 / 1.87
1.53 / 1.75

1.90 / 2.12
1.87 / 2.19
1.79 / 2.06
1.63 / 1.87
1.53 / 1.75

1.90 / 2.12
1.87 / 2.19
1.79 / 2.06
1.63 / 1.87
1.53 / 1.75

Cooling / Heating Capacity (kW)


Unit A

Unit B

Unit C

35 + 71 + 71
50 + 50 + 50
50 + 50 + 60
50 + 50 + 71
50 + 60 + 60
60 + 60 + 60

2.25 / 2.69
3.53 / 4.53
3.41 / 4.25
3.27 / 3.98
3.29 / 4.00
3.83 / 4.53

4.57 / 5.46
3.53 / 4.53
3.41 / 4.25
3.27 / 3.98
3.95 / 4.80
3.83 / 4.53

4.57 / 5.46
3.53 / 4.53
4.09 / 5.10
4.65 / 5.65
3.95 / 4.80
3.83 / 4.53

4 ROOMS
20 + 20 + 20 + 20
20 + 20 + 20 + 25
20 + 20 + 20 + 35
20 + 20 + 20 + 50
20 + 20 + 20 + 60
20 + 20 + 20 + 71
20 + 20 + 25 + 25
20 + 20 + 25 + 35
20 + 20 + 25 + 50
20 + 20 + 25 + 60
20 + 20 + 25 + 71
20 + 20 + 35 + 35
20 + 20 + 35 + 50
20 + 20 + 35 + 60
20 + 20 + 35 + 71
20 + 20 + 50 + 50
20 + 20 + 50 + 60
20 + 20 + 50 + 71
20 + 20 + 60 + 60
20 + 20 + 60 + 71
20 + 25 + 25 + 25
20 + 25 + 25 + 35
20 + 25 + 25 + 50
20 + 25 + 25 + 60
20 + 25 + 25 + 71
20 + 25 + 35 + 35
20 + 25 + 35 + 50
20 + 25 + 35 + 60
20 + 25 + 35 + 71
20 + 25 + 50 + 50
20 + 25 + 50 + 60
20 + 25 + 50 + 71
20 + 25 + 60 + 60
20 + 25 + 60 + 71
20 + 35 + 35 + 35
20 + 35 + 35 + 50
20 + 35 + 35 + 60

2.00 / 2.20
2.00 / 2.40
2.00 / 2.23
1.85 / 2.29
1.73 / 2.15
1.60 / 1.98
2.00 / 2.56
2.00 / 2.40
1.79 / 2.26
1.66 / 2.11
1.56 / 1.94
1.85 / 2.22
1.66 / 2.10
1.57 / 1.96
1.47 / 1.81
1.53 / 1.89
1.43 / 1.76
1.34 / 1.64
1.35 / 1.65
1.26 / 1.54
2.00 / 2.61
1.92 / 2.40
1.73 / 2.20
1.62 / 2.03
1.57 / 1.87
1.79 / 2.19
1.62 / 2.03
1.53 / 1.89
1.42 / 1.75
1.48 / 1.82
1.39 / 1.70
1.30 / 1.59
1.31 / 1.60
1.23 / 1.50
1.66 / 2.03
1.53 / 1.89
1.43 / 1.76

2.00 / 2.20
2.00 / 2.40
2.00 / 2.23
1.85 / 2.29
1.73 / 2.15
1.60 / 1.98
2.00 / 2.56
2.00 / 2.40
1.79 / 2.26
1.66 / 2.11
1.56 / 1.94
1.85 / 2.22
1.66 / 2.10
1.57 / 1.96
1.47 / 1.81
1.53 / 1.89
1.43 / 1.76
1.34 / 1.64
1.35 / 1.65
1.26 / 1.54
2.50 / 3.26
2.40 / 3.00
2.17 / 2.75
2.02 / 2.54
1.90 / 2.34
2.24 / 2.74
2.02 / 2.54
1.91 / 2.36
1.77 / 2.19
1.84 / 2.28
1.74 / 2.13
1.63 / 1.99
1.64 / 2.00
1.53 / 1.88
2.91 / 3.56
2.68 / 3.30
2.50 / 3.08

2.00 / 2.20
2.00 / 2.40
2.00 / 2.23
1.85 / 2.29
1.73 / 2.15
1.60 / 1.98
2.50 / 3.19
2.50 / 3.00
2.24 / 2.83
2.08 / 2.64
1.95 / 2.43
3.25 / 3.88
2.91 / 3.67
2.75 / 3.42
2.57 / 3.16
3.82 / 4.71
3.57 / 4.40
3.35 / 4.10
4.05 / 4.95
3.79 / 4.63
2.50 / 3.26
2.40 / 3.00
2.17 / 2.75
2.02 / 2.54
1.90 / 2.34
3.13 / 3.83
2.83 / 3.55
2.68 / 3.30
2.48 / 3.06
3.69 / 4.55
3.48 / 4.26
3.25 / 3.98
3.93 / 4.80
3.68 / 4.50
2.91 / 3.56
2.68 / 3.30
2.50 / 3.08

Unit D

2.00 / 2.20
2.50 / 3.00
3.50 / 3.91
4.64 / 5.73
5.20 / 6.45
5.69 / 7.05
2.50 / 3.19
3.50 / 4.20
4.48 / 5.65
4.99 / 6.34
5.53 / 6.89
3.25 / 3.88
4.16 / 5.24
4.71 / 5.87
5.20 / 6.42
3.82 / 4.71
4.28 / 5.28
4.76 / 5.82
4.05 / 4.95
4.48 / 5.48
2.50 / 3.26
3.37 / 4.20
4.33 / 5.50
4.85 / 6.09
5.39 / 6.65
3.13 / 3.83
4.04 / 5.08
4.59 / 5.66
5.03 / 6.21
3.69 / 4.55
4.18 / 5.11
4.62 / 5.65
3.93 / 4.80
4.36 / 5.33
2.91 / 3.56
3.82 / 4.71
4.28 / 5.28

Unit E

Unit F

Cooling / Heating Capacity (kW)


Unit D

Unit E

Unit F

1.90 / 2.12
2.34 / 2.74
3.14 / 3.60
4.07 / 4.67
4.58 / 5.25

20 + 35 + 35 + 71
20 + 35 + 50 + 50
20 + 35 + 50 + 60
20 + 35 + 50 + 71
20 + 35 + 60 + 60
20 + 50 + 50 + 50
25 + 25 + 25 + 25
25 + 25 + 25 + 35
25 + 25 + 25 + 50
25 + 25 + 25 + 60
25 + 25 + 25 + 71
25 + 25 + 35 + 35
25 + 25 + 35 + 50
25 + 25 + 35 + 60
25 + 25 + 35 + 71
25 + 25 + 50 + 50
25 + 25 + 50 + 60
25 + 25 + 50 + 71
25 + 25 + 60 + 60
25 + 35 + 35 + 35
25 + 35 + 35 + 50
25 + 35 + 35 + 60
25 + 35 + 35 + 71
25 + 35 + 50 + 50
25 + 35 + 50 + 60
25 + 35 + 60 + 60
25 + 50 + 50 + 50
35 + 35 + 35 + 35
35 + 35 + 35 + 50
35 + 35 + 35 + 60
35 + 35 + 35 + 71
35 + 35 + 50 + 50
35 + 35 + 50 + 60

1.34 / 1.64
1.39 / 1.70
1.31 / 1.60
1.23 / 1.50
1.23 / 1.51
1.27 / 1.55
2.50 / 3.20
2.32 / 2.95
2.08 / 2.64
1.96 / 2.44
1.83 / 2.26
2.17 / 2.71
1.96 / 2.44
1.84 / 2.28
1.73 / 2.12
1.78 / 2.20
1.69 / 2.06
1.58 / 1.93
1.59 / 1.94
2.02 / 2.52
1.84 / 2.28
1.74 / 2.13
1.63 / 1.99
1.69 / 2.06
1.59 / 1.94
1.50 / 1.83
1.54 / 1.89
2.68 / 3.30
2.44 / 2.98
2.29 / 2.80
2.15 / 2.63
2.22 / 2.72
2.10 / 2.57

2.35 / 2.87
2.44 / 2.98
2.29 / 2.80
2.15 / 2.63
2.16 / 2.64
3.18 / 3.88
2.50 / 3.20
2.32 / 2.95
2.08 / 2.64
1.96 / 2.44
1.83 / 2.26
2.17 / 2.71
1.96 / 2.44
1.84 / 2.28
1.73 / 2.12
1.78 / 2.20
1.69 / 2.06
1.58 / 1.93
1.59 / 1.94
2.83 / 3.53
2.58 / 3.19
2.44 / 2.98
2.28 / 2.78
2.36 / 2.89
2.22 / 2.72
2.10 / 2.57
3.09 / 3.77
2.68 / 3.30
2.44 / 2.98
2.29 / 2.80
2.15 / 2.63
2.22 / 2.72
2.10 / 2.57

2.35 / 2.87
3.48 / 4.26
3.27 / 4.00
3.07 / 3.75
3.70 / 4.53
3.18 / 3.88
2.50 / 3.20
2.32 / 2.95
2.08 / 2.64
1.96 / 2.44
1.83 / 2.26
3.03 / 3.79
2.75 / 3.42
2.58 / 3.19
2.42 / 2.96
3.57 / 4.40
3.38 / 4.13
3.16 / 3.86
3.81 / 4.66
2.83 / 3.53
2.58 / 3.19
2.44 / 2.98
2.28 / 2.78
3.38 / 4.13
3.18 / 3.88
3.60 / 4.40
3.09 / 3.77
2.68 / 3.30
2.44 / 2.98
2.29 / 2.80
2.15 / 2.63
3.18 / 3.88
3.00 / 3.67

4.76 / 5.82
3.48 / 4.26
3.93 / 4.80
4.36 / 5.33
3.70 / 4.53
3.18 / 3.88
2.50 / 3.20
3.25 / 4.14
4.16 / 5.28
4.71 / 5.87
5.20 / 6.42
3.03 / 3.79
3.93 / 4.89
4.43 / 5.46
4.92 / 6.01
3.57 / 4.40
4.05 / 4.95
4.48 / 5.48
3.81 / 4.66
2.83 / 3.53
3.69 / 4.55
4.18 / 5.11
4.62 / 5.65
3.38 / 4.13
3.81 / 4.66
3.60 / 4.40
3.09 / 3.77
2.68 / 3.30
3.48 / 4.26
3.93 / 4.80
4.36 / 5.33
3.18 / 3.88
3.60 / 4.40

5 ROOMS
20 + 20 + 20 + 20 + 20
20 + 20 + 20 + 20 + 25
20 + 20 + 20 + 20 + 35
20 + 20 + 20 + 20 + 50
20 + 20 + 20 + 20 + 60
20 + 20 + 20 + 20 + 71
20 + 20 + 20 + 25 + 25
20 + 20 + 20 + 25 + 35
20 + 20 + 20 + 25 + 50
20 + 20 + 20 + 25 + 60
20 + 20 + 20 + 25 + 71
20 + 20 + 20 + 35 + 35
20 + 20 + 20 + 35 + 50
20 + 20 + 20 + 35 + 60
20 + 20 + 20 + 35 + 71
20 + 20 + 20 + 50 + 50
20 + 20 + 20 + 50 + 60
20 + 20 + 25 + 25 + 25
20 + 20 + 25 + 25 + 35
20 + 20 + 25 + 25 + 50
20 + 20 + 25 + 25 + 60

2.00 / 2.20
2.00 / 2.38
1.97 / 2.28
1.83 / 2.06
1.71 / 1.91
1.60 / 1.77
2.00 / 2.42
1.93 / 2.23
1.78 / 1.99
1.66 / 1.85
1.55 / 1.72
1.83 / 2.06
1.66 / 1.85
1.56 / 1.73
1.46 / 1.61
1.51 / 1.68
1.44 / 1.58
1.97 / 2.33
1.90 / 2.14
1.71 / 1.91
1.61 / 1.79

2.00 / 2.20
2.00 / 2.38
1.97 / 2.28
1.83 / 2.06
1.71 / 1.91
1.60 / 1.77
2.00 / 2.42
1.93 / 2.23
1.78 / 1.99
1.66 / 1.85
1.55 / 1.72
1.83 / 2.06
1.66 / 1.85
1.56 / 1.73
1.46 / 1.61
1.51 / 1.68
1.44 / 1.58
1.97 / 2.33
1.90 / 2.14
1.71 / 1.91
1.61 / 1.79

2.00 / 2.20
2.00 / 2.38
1.97 / 2.28
1.83 / 2.06
1.71 / 1.91
1.60 / 1.77
2.00 / 2.42
1.93 / 2.23
1.78 / 1.99
1.66 / 1.85
1.55 / 1.72
1.83 / 2.06
1.66 / 1.85
1.56 / 1.73
1.46 / 1.61
1.51 / 1.68
1.44 / 1.58
2.46 / 2.91
2.38 / 2.68
2.14 / 2.39
2.02 / 2.23

2.00 / 2.20
2.00 / 2.38
1.97 / 2.28
1.83 / 2.06
1.71 / 1.91
1.60 / 1.77
2.50 / 3.02
2.42 / 2.79
2.22 / 2.48
2.07 / 2.31
1.94 / 2.15
3.20 / 3.61
2.90 / 3.23
2.73 / 3.03
2.55 / 2.83
3.78 / 4.19
3.59 / 3.94
2.46 / 2.91
2.38 / 2.68
2.14 / 2.39
2.02 / 2.23

Air Conditioning
1.4.19 1.121

20 + 20 + 20 + 20 + 25 + 25
20 + 20 + 20 + 20 + 25 + 35
20 + 20 + 20 + 20 + 25 + 50
20 + 20 + 20 + 20 + 25 + 60
20 + 20 + 20 + 20 + 35 + 35
20 + 20 + 20 + 20 + 35 + 50
20 + 20 + 20 + 25 + 25 + 25
20 + 20 + 20 + 25 + 25 + 35
20 + 20 + 20 + 25 + 25 + 50
20 + 20 + 20 + 25 + 25 + 60
20 + 20 + 20 + 25 + 35 + 35
20 + 20 + 20 + 25 + 35 + 50
20 + 20 + 20 + 25 + 35 + 60
20 + 20 + 20 + 35 + 35 + 35
20 + 20 + 20 + 35 + 35 + 50
20 + 20 + 25 + 25 + 25 + 25
20 + 20 + 25 + 25 + 25 + 35
20 + 20 + 25 + 25 + 25 + 50
20 + 20 + 25 + 25 + 25 + 60
20 + 20 + 25 + 25 + 35 + 35
20 + 20 + 25 + 25 + 35 + 50
20 + 20 + 25 + 35 + 35 + 35
20 + 20 + 35 + 35 + 35 + 35
20 + 25 + 25 + 25 + 25 + 25
20 + 25 + 25 + 25 + 25 + 35
20 + 25 + 25 + 25 + 25 + 50
20 + 25 + 25 + 25 + 25 + 60
20 + 25 + 25 + 25 + 35 + 35
20 + 25 + 25 + 25 + 35 + 50
20 + 25 + 25 + 35 + 35 + 35
25 + 25 + 25 + 25 + 25 + 25
25 + 25 + 25 + 25 + 25 + 35
25 + 25 + 25 + 25 + 25 + 50
25 + 25 + 25 + 25 + 35 + 35
25 + 25 + 25 + 35 + 35 + 35
2.00 / 2.20
2.50 / 2.98
3.44 / 3.99
4.58 / 5.15
5.14 / 5.74
5.69 / 6.30
2.50 / 3.02
3.38 / 3.91
4.44 / 4.96
4.97 / 5.54
5.51 / 6.10
3.20 / 3.61
4.14 / 4.62
4.68 / 5.19
5.18 / 5.73
3.78 / 4.19
4.31 / 4.73
2.46 / 2.91
3.33 / 3.75
4.29 / 4.79
4.84 / 5.36

1.83 / 2.15
1.74 / 2.00
1.57 / 1.81
1.48 / 1.70
1.63 / 1.87
1.48 / 1.70
1.79 / 2.07
1.68 / 1.93
1.53 / 1.75
1.44 / 1.65
1.57 / 1.81
1.44 / 1.65
1.36 / 1.56
1.48 / 1.70
1.36 / 1.56
1.74 / 2.00
1.63 / 1.87
1.48 / 1.70
1.39 / 1.60
1.53 / 1.75
1.39 / 1.60
1.44 / 1.65
1.36 / 1.56
1.68 /1.93
1.57 / 1.81
1.44 / 1.65
1.36 / 1.56
1.48 / 1.70
1.36 / 1.56
1.39 / 1.60
2.03 / 2.33
1.91 / 2.19
1.74 / 2.00
1.79 / 2.06
1.69 / 1.94

1.83 / 2.15
1.74 / 2.00
1.57 / 1.81
1.48 / 1.70
1.63 / 1.87
1.48 / 1.70
1.79 / 2.07
1.68 / 1.93
1.53 / 1.75
1.44 / 1.65
1.57 / 1.81
1.44 / 1.65
1.36 / 1.56
1.48 / 1.70
1.36 / 1.56
1.74 / 2.00
1.63 / 1.87
1.48 / 1.70
1.39 / 1.60
1.53 / 1.75
1.39 / 1.60
1.44 / 1.65
1.36 / 1.56
2.10 / 2.41
1.97 / 2.26
1.79 / 2.06
1.69 / 1.94
1.85 / 2.12
1.69 / 1.96
1.74 / 2.00
2.03 / 2.33
1.91 / 2.19
1.74 / 2.00
1.79 / 2.06
1.69 / 1.94

1.83 / 2.15
1.74 / 2.00
1.57 / 1.81
1.48 / 1.70
1.63 / 1.87
1.48 / 1.70
1.79 / 2.07
1.68 / 1.93
1.53 / 1.75
1.44 / 1.65
1.57 / 1.81
1.44 / 1.65
1.36 / 1.56
1.48 / 1.70
1.36 / 1.56
2.18 / 2.50
2.03 / 2.33
1.85 / 2.12
1.74 / 2.00
1.91 / 2.19
1.74 / 2.00
1.79 / 2.06
2.37 / 2.72
2.10 / 2.41
1.97 / 2.26
1.79 / 2.06
1.69 / 1.94
1.85 / 2.12
1.69 / 1.96
1.74 / 2.00
2.03 / 2.33
1.91 / 2.19
1.74 / 2.00
1.79 / 2.06
1.69 / 1.94

1.83 / 2.15
1.74 / 2.00
1.57 / 1.81
1.48 / 1.70
1.63 / 1.87
1.48 / 1.70
2.24 / 2.59
2.10 / 2.41
1.91 / 2.19
1.79 / 2.06
1.97 / 2.26
1.79 / 2.06
1.69 / 1.94
2.59 / 2.97
2.37 / 2.72
2.18 / 2.50
2.03 / 2.33
1.85 / 2.12
1.74 / 2.00
1.91 / 2.19
1.74 / 2.00
2.51 / 2.88
2.37 / 2.72
2.10 / 2.41
1.97 / 2.26
1.79 / 2.06
1.69 / 1.94
1.85 / 2.12
1.69 / 1.96
2.44 / 2.80
2.03 / 2.33
1.91 / 2.19
1.74 / 2.00
1.79 / 2.06
2.37 / 2.72

2.29 / 2.69
2.18 / 2.50
1.97 / 2.26
1.85 / 2.12
2.85 / 3.27
2.59 / 2.97
2.24 / 2.59
2.10 / 2.41
1.91 / 2.19
1.79 / 2.06
2.75 / 3.16
2.51 / 2.88
2.37 / 2.72
2.59 / 2.97
2.37 / 2.72
2.18 / 2.50
2.03 / 2.33
1.85 / 2.12
1.74 / 2.00
2.67 / 3.06
2.44 / 2.80
2.51 / 2.88
2.37 / 2.72
2.10 / 2.41
1.97 / 2.26
1.79 / 2.06
1.69 / 1.94
2.59 / 2.97
2.37 / 2.72
2.44 / 2.80
2.03 / 2.33
1.91 / 2.19
1.74 / 2.00
2.51 / 2.88
2.37 / 2.72

2.29 / 2.69
3.05 / 3.50
3.94 / 4.52
4.44 / 5.09
2.85 / 3.27
3.70 / 4.24
2.24 / 2.59
2.94 / 3.38
3.81 / 4.38
4.31 / 4.94
2.75 / 3.16
3.59 / 4.12
4.07 / 4.67
2.59 / 2.97
3.39 / 3.89
2.18 / 2.50
2.85 / 3.27
3.70 / 4.24
4.18 / 4.80
2.67 / 3.06
3.49 / 4.00
2.51 / 2.88
2.37 / 2.72
2.10 / 2.41
2.75 / 3.16
3.59 / 4.12
4.07 / 4.67
2.59 / 2.97
3.39 / 3.89
2.44 / 2.80
2.03 / 2.33
2.67 / 3.06
3.49 / 4.00
2.51 / 2.88
2.37 / 2.72

MXZ-8B140VA
1 OUTDOOR UNIT
Indoor Unit
Combination

UPTO 8 INDOOR UNITS


Cooling / Heating Capacity (kW)
Unit A

Unit B

1 ROOM
20
25
35
50
60
71

2.00 / 2.20
2.50 / 3.60
3.50 / 4.00
5.00 / 7.20
6.00 / 7.90
7.10 / 8.60

2 ROOMS
20 + 20
20 + 25

2.00 / 2.30 2.00 / 2.30


2.00 / 2.27 2.50 / 2.83

Unit C

Unit D

Unit E

Unit F

Unit G

The Flexible & Efficient Multi-Split Range

Unit H

1.4.20

Multi-Split Combinations
MXZ-8B140VA
1 OUTDOOR UNIT
Indoor Unit
Combination

Indoor Unit
Combination

UPTO 8 INDOOR UNITS


Cooling / Heating Capacity (kW)
Unit A

Unit B

20 + 35
20 + 50
20 + 60
20 + 71
25 + 25
25 + 35
25 + 50
25 + 60
25 + 71
35 + 35
35 + 50
35 + 60
35 + 71
50 + 50
50 + 60
50 + 71
60 + 60
60 + 71
71 + 71

2.00 / 2.29
2.00 / 2.29
2.00 / 2.28
2.00 / 2.29
2.50 / 2.85
2.50 / 2.88
2.50 / 2.87
2.50 / 2.85
2.50 / 2.86
3.50 / 4.00
3.50 / 3.99
3.50 / 4.02
3.00 / 4.00
5.00 / 5.70
5.00 / 5.73
3.97 / 5.70
6.00 / 6.85
6.00 / 6.87
7.00 / 8.00

3.50 / 4.01
5.00 / 5.71
6.00 / 6.82
7.10 / 8.11
2.50 / 2.85
3.50 / 4.02
5.00 / 5.73
6.00 / 6.85
7.10 / 8.14
3.50 / 4.00
5.00 / 5.71
6.00 / 6.88
7.10 / 8.10
5.00 / 5.70
6.00 / 6.87
5.63 / 8.10
6.00 / 6.85
7.10 / 8.13
7.00 / 8.00

3 ROOMS
20 + 20 +20
20 + 20 + 25
20 + 20 + 35
20 + 20 + 50
20 + 20 + 60
20 + 20 + 71
20 + 25 + 25
20 + 25 + 35
20 + 25 + 50
20 + 25 + 60
20 + 25 + 71
20 + 35 + 35
20 + 35 + 50
20 + 35 + 60
20 + 35 + 71
20 + 50 + 50
20 + 50 + 60
20 + 50 +71
20 + 60 + 60
20 + 60 + 71
20 + 71 + 71
25 + 25 + 25
25 + 25 + 35
25 + 25 + 50

2.00 / 2.30
2.00 / 2.28
2.00 / 2.29
2.00 / 2.29
2.00 / 2.28
2.00 / 2.29
2.00 / 2.28
2.00 / 2.28
2.00 / 2.29
2.00 / 2.28
2.00 / 2.29
2.00 / 2.28
2.00 / 2.29
2.00 / 2.28
2.00 / 2.29
2.00 / 2.28
2.00 / 2.29
1.99 / 2.27
2.00 / 2.28
1.85/ 2.12
1.72 / 1.98
2.50 / 2.86
2.50 / 2.85
2.50 / 2.85

2.00 / 2.30
2.00 / 2.28
2.00 / 2.29
2.00 / 2.29
2.00 / 2.28
2.00 / 2.29
2.50 / 2.86
2.50 / 2.84
2.50 / 2.87
2.50 / 2.86
2.50 / 2.87
3.50 / 4.01
3.50 / 4.00
3.50 / 3.99
3.50 / 4.00
5.00 / 5.71
5.00 / 5.73
4.96 / 5.67
6.00 / 6.86
5.56 / 6.36
6.14 / 7.01
2.50 / 2.86
2.50 / 2.85
2.50 / 2.85

Unit C

2.00 / 2.30
2.00 / 2.84
3.50 / 4.01
5.00 / 5.74
6.00 / 6.84
7.10 / 8.12
2.50 / 2.86
3.50 / 3.98
5.00 / 5.74
6.00 / 6.86
7.10 / 8.14
3.50 / 4.01
5.00 / 5.74
6.00 / 6.83
7.10 / 8.11
5.00 / 5.71
6.00 / 6.88
7.05 / 8.06
6.00 / 6.86
6.58 / 7.52
6.14 / 7.01
2.50 / 2.86
3.50 / 3.99
5.00 / 5.70

Unit D

Unit E

Unit F

Unit G

Unit H

20 + 25 + 35 + 50
20 + 25 + 35 + 60
20 + 25 + 35 + 71
20 + 25 + 50 + 50
20 + 25 + 50 + 60
20 + 25 + 50 + 71
20 + 25 + 60 + 60
20 + 25 + 60 + 71
20 + 35 + 35 + 35
20 + 35 + 35 + 50
20 + 35 + 35 + 60
20 + 35 + 35 + 71
20 + 35 + 50 + 50
20 + 35 + 50 + 60
20 + 35 + 50 + 71
20 + 35 + 60 + 60
20 + 50 + 50 + 50
20 + 50 + 50 + 60
25 + 25 + 25 + 25
25 + 25 + 25 + 35
25 + 25 + 25 + 50
25 + 25 + 25 + 60
25 + 25 + 25 + 71
25 + 25 + 35 + 35
25 + 25 + 35 + 50
25 + 25 + 35 + 60
25 + 25 + 35 + 71
25 + 25 + 50 + 50
25 + 25 + 50 + 60
25 + 25 + 50 + 71
25 + 25 + 60 + 60
25 + 25 + 60 + 71
25 + 35 + 35 + 35
25 + 35 + 35 + 50
25 + 35 + 35 + 60
25 + 35 + 35 + 71
25 + 35 + 50 + 50
25 + 35 + 50 + 60
25 + 35 + 50 + 71
25 + 35 + 60 + 60
25 + 50 + 50 + 50
25 + 50 + 50 + 60
35 + 35 + 35 + 35
35 + 35 + 35 + 50
35 + 35 + 35 + 60
35 + 35 + 35 + 71
35 + 35 + 50 + 50

Cooling / Heating Capacity (kW)


Unit A

Unit B

Unit C

Unit D

2.00 / 2.29
2.00 / 2.29
1.85 / 2.12
1.93 / 2.21
1.81 / 2.06
1.69 / 1.82
1.70 / 1.94
1.59 / 1.82
2.00 / 2.29
2.00 / 2.29
1.87 / 2.13
1.74 / 1.99
1.81 / 2.06
1.70 / 1.94
1.59 / 1.82
1.60 / 1.83
1.64 / 1.87
1.56 / 1.78
2.50 / 2.85
2.50 / 2.86
2.50 / 2.86
2.50 / 2.85
2.50 / 2.74
2.50 / 2.85
2.50 / 2.85
2.41 / 2.76
2.24 / 2.56
2.33 / 2.67
2.19 / 2.50
2.05 / 2.34
2.06 / 2.35
1.93 / 2.21
2.50 / 2.87
2.41 / 2.76
2.26 / 2.58
2.11 / 2.41
2.18 / 2.50
2.06 / 2.35
1.93 / 2.21
1.94 / 2.22
2.50 / 2.29
1.89 / 2.16
3.50 / 4.00
3.16 / 3.61
2.97 / 3.39
2.78 / 3.18
2.88 / 3.29

2.50 / 2.87
2.50 / 2.86
2.32 / 2.65
2.41 / 2.75
2.26 / 2.58
2.11 / 2.41
2.12 / 2.42
1.99 / 2.27
3.50 / 4.00
3.50 / 4.00
3.27 / 3.73
3.04 / 3.48
3.15 / 3.61
2.97 / 3.39
2.78 / 3.18
2.80 / 3.19
4.12 / 4.71
3.89 / 4.44
2.50 / 2.85
2.50 / 2.86
2.50 / 2.86
2.50 / 2.85
2.50 / 2.74
2.50 / 2.85
2.50 / 2.85
2.41 / 2.76
2.24 / 2.56
2.33 / 2.67
2.19 / 2.50
2.05 / 2.34
2.06 / 2.35
1.93 / 2.21
3.50 / 4.01
3.38 / 3.86
3.16 / 3.61
2.95 / 3.37
3.06 / 3.50
2.88 / 3.29
2.71 / 3.09
2.72 / 3.11
4.00 / 4.57
3.78 / 4.32
3.50 / 4.00
3.16 / 3.61
2.97 / 3.39
2.78 / 3.18
2.88 / 3.29

3.50 / 4.01
3.50 / 4.00
3.25 / 3.71
4.83 / 5.52
4.52 / 5.16
4.22 / 4.82
5.09 / 5.82
4.77 / 5.45
3.50 / 4.00
3.50 / 4.00
3.27 / 3.73
3.04 / 3.48
4.52 / 5.16
4.24 / 4.85
3.98 / 4.55
4.80 / 5.49
4.12 / 4.71
3.89 / 4.44
2.50 / 2.85
2.50 / 2.86
2.50 / 2.86
2.50 / 2.85
2.50 / 2.74
3.50 / 4.00
3.50 / 3.99
3.38 / 3.86
3.14 / 3.59
4.67 / 5.33
4.38 / 5.00
4.09 / 4.68
4.94 / 5.65
4.64 / 5.30
3.50 / 4.01
3.38 / 3.86
3.16 / 3.61
2.95 / 3.37
4.38 / 5.00
4.12 / 4.71
3.87 / 4.42
4.67 / 5.33
4.00 / 4.57
3.78 / 4.32
3.50 / 4.00
3.16 / 3.61
2.97 / 3.39
2.78 / 3.18
4.12 / 4.71

5.00 / 5.73
6.00 / 6.85
6.58 / 7.52
4.83 / 5.52
5.41 / 6.19
5.98 / 6.84
5.09 / 5.82
5.65 / 6.45
3.50 / 4.00
5.00 / 5.71
5.59 / 6.40
6.17 / 7.05
4.52 / 5.16
5.09 / 5.82
5.65 / 6.45
4.80 / 5.49
4.12 / 4.71
4.66 / 5.33
2.50 / 2.85
3.50 / 4.01
5.00 / 5.72
6.00 / 6.84
7.10 / 7.78
3.50 / 4.00
5.00 / 5.70
5.79 / 6.62
6.37 / 7.28
4.67 / 5.33
5.24 / 6.00
5.81 / 6.64
4.94 / 5.65
5.49 / 6.28
3.50 / 4.01
4.83 / 5.52
5.42 / 6.19
5.99 / 6.84
4.38 / 5.00
4.94 / 5.65
5.49 / 6.28
4.67 / 5.33
4.00 / 4.57
4.54 / 5.19
3.50 / 4.00
4.52 / 5.16
5.09 / 5.82
5.65 / 6.45
4.12 / 4.71

Unit E

Unit F

Unit G

Unit H

25 + 25 + 60
25 + 25 + 71
25 + 35 + 35
25 + 35 + 50
25 + 35 + 60
25 + 35 + 71
25 + 50 + 50
25 + 50 + 60
25 + 50 + 71
25 + 60 + 60
25 + 60 + 71
25 + 71 + 71
35 + 35 + 35
35 + 35 + 50
35 + 35 + 60
35 + 35 + 71
35 + 50 + 50
35 + 50 + 60
35 + 50 + 71
35 + 60 + 60
35 + 60 + 71
35 + 71 + 71
50 + 50 + 50
50 + 50 + 60
50 + 50 + 71
50 + 60 + 60
60 + 60 + 60

2.50 / 2.86
2.50 / 2.85
2.50 / 2.86
2.50 / 2.86
2.50 / 2.85
2.50 / 2.86
2.50 / 2.86
2.50 / 2.85
2.40 / 2.74
2.41 / 2.76
2.24 / 2.56
2.10 / 2.40
3.50 / 4.00
3.50 / 4.00
3.50 / 4.01
3.48 / 3.97
3.50 / 3.99
3.38 / 3.86
3.14 / 3.59
3.16 / 3.61
2.95 / 3.37
2.77 / 3.16
4.67 / 5.33
4.38 / 5.00
4.09 / 4.68
4.12 / 4.70
4.67 / 5.33

2.50 / 2.86
2.50 / 2.85
3.50 / 4.02
3.50 / 4.01
3.50 / 4.00
3.50 / 4.01
5.00 / 5.72
5.00 / 5.70
4.79 / 5.48
5.79 / 6.62
5.38 / 6.15
5.95 / 6.80
3.50 / 4.00
3.50 / 4.00
3.50 / 4.01
3.48 / 3.97
5.00 / 5.70
4.83 / 5.52
4.49 / 5.13
5.42 / 6.19
5.06 / 5.78
5.62 / 6.42
4.67 / 5.33
4.38 / 5.00
4.09 / 4.68
4.94 / 5.65
4.67 / 5.33

6.00 / 6.87
7.10 / 8.10
3.50 / 4.02
5.00 / 5.73
6.00 / 6.85
7.10 / 8.13
5.00 / 5.72
6.00 / 6.84
6.81 / 7.78
5.79 / 6.62
6.37 / 7.28
5.95 / 6.80
3.50 / 4.00
5.00 / 5.70
6.00 / 6.88
7.05 / 8.06
5.00 / 5.70
5.79 / 6.62
6.37 / 7.28
5.42 / 6.19
5.99 / 6.84
5.62 / 6.42
4.67 / 5.33
5.25 / 6.00
5.81 / 6.64
4.94 / 5.65
4.67 / 5.33

4 ROOMS
20 + 20 + 20 + 20
20 + 20 + 20 + 25
20 + 20 + 20 + 35
20 + 20 + 20 + 50
20 + 20 + 20 + 60
20 + 20 + 20 + 71
20 + 20 + 25 + 25
20 + 20 + 25 + 35
20 + 20 + 25 + 50
20 + 20 + 25 + 60
20 + 20 + 25 + 71
20 + 20 + 35 + 35
20 + 20 + 35 + 50
20 + 20 + 35 + 60
20 + 20 + 35 + 71
20 + 20 + 50 + 50
20 + 20 + 50 + 60
20 + 20 + 50 + 71
20 + 20 + 60 + 60
20 + 20 + 60 + 71
20 + 20 + 71 + 71
20 + 25 + 25 + 25
20 + 25 + 25 + 35
20 + 25 + 25 + 50
20 + 25 + 25 + 60
20 + 25 + 25 + 71
20 + 25 + 35 + 35

2.00 / 2.27
2.00 / 2.28
2.00 / 2.29
2.00 / 2.29
2.00 / 2.28
2.00 / 2.29
2.00 / 2.29
2.00 / 2.28
2.00 / 2.28
2.00 / 2.29
2.00 / 2.28
2.00 / 2.29
2.00 / 2.29
2.00 / 2.28
1.92 / 2.19
2.00 / 2.29
1.87 / 2.13
1.74 / 1.99
1.75 / 2.00
1.64 / 1.87
1.54 / 1.76
2.00 / 2.29
2.00 / 2.29
2.00 / 2.28
2.00 / 2.29
1.99 / 2.27
2.00 / 2.28

2.00 / 2.27
2.00 / 2.28
2.00 / 2.29
2.00 / 2.29
2.00 / 2.28
2.00 / 2.29
2.00 / 2.29
2.00 / 2.28
2.00 / 2.28
2.00 / 2.29
2.00 / 2.28
2.00 / 2.29
2.00 / 2.29
2.00 / 2.28
1.92 / 2.19
2.00 / 2.29
1.87 / 2.13
1.74 / 1.99
1.75 / 2.00
1.64 / 1.87
1.54 / 1.76
2.50 / 2.87
2.50 / 2.86
2.50 / 2.85
2.50 / 2.87
2.48 / 2.84
2.48 / 2.84

2.00 / 2.27
2.00 / 2.28
2.00 / 2.29
2.00 / 2.29
2.00 / 2.28
2.00 / 2.29
2.50 / 2.86
2.50 / 2.85
2.50 / 2.85
2.50 / 2.86
2.50 / 2.85
3.50 / 4.01
3.50 / 4.00
3.50 / 3.99
3.36 / 3.84
5.00 / 5.71
4.67 / 5.33
4.35 / 4.97
5.25 / 6.00
4.91 / 5.61
5.46 / 6.24
2.50 / 2.87
2.50 / 2.86
2.50 / 2.85
2.50 / 2.87
2.48 / 2.84
3.50 / 3.99

Air Conditioning
1.4.21 1.121

2.00 / 2.27
2.50 / 2.85
3.50 / 4.02
5.00 / 5.73
6.00 / 6.85
7.10 / 8.13
2.50 / 2.86
3.50 / 3.99
5.00 / 5.69
6.00 / 6.86
7.10 / 8.09
3.50 / 4.01
5.00 / 5.72
5.00 / 6.84
6.80 / 7.78
5.00 / 5.71
5.59 / 6.40
6.17 / 7.05
5.25 / 6.00
5.81 / 6.64
5.46 / 6.24
2.50 / 2.87
2.50 / 2.86
5.00 / 5.71
6.00 / 6.87
7.05 / 8.05
3.50 / 3.99

35 + 35 + 50 + 60
35 + 50 + 50 + 50

2.72 / 3.11 2.72 / 3.11 3.89 / 4.44 4.67 / 5.33


2.65 / 3.03 3.78 / 4.32 3.78 / 4.32 3.78 / 4.32

5 ROOMS
20 + 20 + 20 + 20 + 20
20 + 20 + 20 + 20 + 25
20 + 20 + 20 + 20 + 35
20 + 20 + 20 + 20 + 50
20 + 20 + 20 + 20 + 60
20 + 20 + 20 + 20 + 71
20 + 20 + 20 + 25 + 25
20 + 20 + 20 + 25 + 35
20 + 20 + 20 + 25 + 50
20 + 20 + 20 + 25 + 60
20 + 20 + 20 + 25 + 71
20 + 20 + 20 + 35 + 35
20 + 20 + 20 + 35 + 50
20 + 20 + 20 + 35 + 60
20 + 20 + 20 + 35 + 71
20 + 20 + 20 + 50 + 50
20 + 20 + 20 + 50 + 60
20 + 20 + 20 + 50 + 71
20 + 20 + 20 + 60 + 60
20 + 20 + 25 + 25 + 25
20 + 20 + 25 + 25 + 35
20 + 20 + 25 + 25 + 50
20 + 20 + 25 + 25 + 60
20 + 20 + 25 + 25 + 71
20 + 20 + 25 + 35 + 35
20 + 20 + 25 + 35 + 50
20 + 20 + 25 + 35 + 60
20 + 20 + 25 + 35 + 71
20 + 20 + 25 + 50 + 50
20 + 20 + 25 + 50 + 60
20 + 20 + 25 + 60 + 60
20 + 20 + 35 + 35 + 35
20 + 20 + 35 + 35 + 50
20 + 20 + 35 + 35 + 60
20 + 20 + 35 + 35 + 71
20 + 20 + 35 + 50 + 50
20 + 20 + 35 + 50 + 60
20 + 25 + 25 + 25 + 25
20 + 25 + 25 + 25 + 35
20 + 25 + 25 + 25 + 50
20 + 25 + 25 + 25 + 60
20 + 25 + 25 + 25 + 71
20 + 25 + 25 + 35 + 35
20 + 25 + 25 + 35 + 50
20 + 25 + 25 + 35 + 60
20 + 25 + 25 + 35 + 71
20 + 25 + 25 + 50 + 50
20 + 25 + 25 + 50 + 60
20 + 25 + 35 + 35 + 35
20 + 25 + 35 + 35 + 50
20 + 25 + 35 + 35 + 60
20 + 25 + 35 + 50 + 50

2.00 / 2.28
2.00 / 2.29
2.00 / 2.28
2.00 / 2.29
2.00 / 2.29
1.85 / 2.12
2.00 / 2.29
2.00 / 2.28
2.00 / 2.28
1.93 / 2.21
1.79 / 2.05
2.00 / 2.29
1.93 / 2.21
1.81 / 2.06
1.69 / 1.93
1.75 / 2.00
1.65 / 1.88
1.55 / 1.77
1.56 / 1.78
2.00 / 2.27
2.00 / 2.29
2.00 / 2.29
1.87 / 2.13
1.74 / 1.99
2.00 / 2.28
1.97 / 2.13
1.75 / 2.00
1.64 / 1.87
1.70 / 1.94
1.60 / 1.83
1.51 / 1.73
1.93 / 2.21
1.75 / 2.00
1.65 / 1.88
1.55 / 1.77
1.60 / 1.83
1.51 / 1.73
2.00 / 2.28
2.00 / 2.29
1.93 / 2.21
1.81 / 2.06
1.69 / 1.93
2.00 / 2.29
1.81 / 2.06
1.70 / 1.94
1.59 / 1.82
1.64 / 1.88
1.56 / 1.78
1.87 / 2.13
1.70 /1.94
1.60 / 1.83
1.56 / 1.78

2.00 / 2.28
2.00 / 2.29
2.00 / 2.28
2.00 / 2.29
2.00 / 2.29
1.85 / 2.12
2.00 / 2.29
2.00 / 2.28
2.00 / 2.28
1.93 / 2.21
1.79 / 2.05
2.00 / 2.29
1.93 / 2.21
1.81 / 2.06
1.69 / 1.93
1.75 / 2.00
1.65 / 1.88
1.55 / 1.77
1.56 / 1.78
2.00 / 2.27
2.00 / 2.29
2.00 / 2.29
1.87 / 2.13
1.74 / 1.99
2.00 / 2.28
1.97 / 2.13
1.75 / 2.00
1.64 / 1.87
1.70 / 1.94
1.60 / 1.83
1.51 / 1.73
1.93 / 2.21
1.75 / 2.00
1.65 / 1.88
1.55 / 1.77
1.60 / 1.83
1.51 / 1.73
2.50 / 2.85
2.50 / 2.87
2.41 / 2.76
2.26 / 2.58
2.11 / 2.41
2.50 / 2.86
2.26 / 2.58
2.12 / 2.42
1.99 / 2.27
2.06 / 2.35
1.94 / 2.22
2.32 / 2.67
2.12 / 2.42
2.00 / 2.29
1.94 / 2.22

2.00 / 2.28
2.00 / 2.29
2.00 / 2.28
2.00 / 2.29
2.00 / 2.29
1.85 / 2.12
2.00 / 2.29
2.00 / 2.28
2.00 / 2.28
1.93 / 2.21
1.79 / 2.05
2.00 / 2.29
1.93 / 2.21
1.81 / 2.06
1.69 / 1.93
1.75 / 2.00
1.65 / 1.88
1.55 / 1.77
1.56 / 1.78
2.50 / 2.85
2.50 / 2.86
2.50 / 2.86
2.33 / 2.67
2.17 / 2.48
2.50 / 2.85
2.46 / 2.67
2.19 / 2.50
2.05 / 2.34
2.12 / 2.42
2.00 / 2.29
1.89 / 2.16
3.38 / 3.86
3.06 / 3.50
2.88 / 3.29
2.71 / 3.09
2.80 / 3.20
2.65 / 3.03
2.50 / 2.85
2.50 / 2.87
2.41 / 2.76
2.26 / 2.58
2.11 / 2.41
2.50 / 2.86
2.26 / 2.58
2.12 / 2.42
1.99 / 2.27
2.06 / 2.35
1.94 / 2.22
3.27 / 3.73
2.97 / 3.39
2.80 / 3.20
2.72 / 3.11

2.00 / 2.28
2.00 / 2.29
2.00 / 2.28
2.00 / 2.29
2.00 / 2.29
1.85 / 2.12
2.50 / 2.86
2.50 / 2.85
2.50 / 2.85
2.41 / 2.76
2.24 / 2.56
3.50 / 4.01
3.38 / 3.86
3.16 / 3.61
2.95 / 3.37
4.37 / 5.00
4.12 / 4.71
3.87 / 4.42
4.66 / 5.33
2.50 / 2.85
2.50 / 2.86
2.50 / 2.86
2.33 / 2.67
2.17 / 2.48
3.50 / 3.99
3.45 / 3.73
3.06 / 3.50
2.87 / 3.27
4.24 / 4.85
4.00 / 4.57
4.54 / 5.19
3.38 / 3.86
3.06 / 3.50
2.88 / 3.29
2.71 / 3.09
4.00 / 4.57
3.78 / 4.32
2.50 / 2.85
2.50 / 2.87
2.41 / 2.76
2.26 / 2.58
2.11 / 2.41
3.50 / 3.99
3.16 / 3.61
2.97 / 3.39
2.78 / 3.18
4.12 / 4.71
3.89 / 4.44
3.27 / 3.73
2.97 / 3.39
2.80 / 3.20
3.89 / 4.44

2.00 / 2.28
2.50 / 2.84
3.50 / 3.98
5.00 / 5.73
6.00 / 6.84
6.58 / 7.52
2.50 / 2.86
3.50 / 4.00
5.00 / 5.70
5.79 / 6.61
6.37 / 7.28
3.50 / 4.01
4.83 / 5.51
5.41 / 6.19
5.98 / 6.84
4.37 / 5.00
4.93 / 5.65
5.48 / 6.27
4.66 / 5.33
2.50 / 2.85
3.50 / 4.00
5.00 / 5.70
5.60 / 6.40
6.17 / 7.06
3.50 / 3.99
4.66 / 5.33
5.25 / 6.00
5.80 / 6.64
4.24 / 4.85
4.80 / 5.48
4.54 / 5.19
3.38 / 3.86
4.38 / 5.00
4.94 / 5.65
2.48 / 6.28
4.00 / 4.57
4.54 / 5.19
2.50 / 2.85
3.50 / 4.00
4.83 / 5.51
5.41 / 6.19
5.98 / 6.84
3.50 / 3.99
4.51 / 5.16
5.09 / 5.82
5.65 / 6.45
4.12 / 4.71
4.67 / 5.33
3.27 / 3.73
4.24 / 4.85
4.80 / 5.48
3.89 / 4.44

The Flexible & Efficient Multi-Split Range

1.4.22

Multi-Split Combinations
MXZ-8B140VA
1 OUTDOOR UNIT
Indoor Unit
Combination

Indoor Unit
Combination

UPTO 8 INDOOR UNITS

Cooling / Heating Capacity (kW)


Unit A

Cooling / Heating Capacity (kW)


Unit A

Unit B

Unit C

Unit D

Unit E

20 + 35 + 35 + 35 + 35
20 + 35 + 35 + 35 + 50
20 + 35 + 35 + 35 + 60
25 + 25 + 25 + 25 + 25
25 + 25 + 25 + 25 + 35
25 + 25 + 25 + 25 + 50
25 + 25 + 25 + 25 + 60
25 + 25 + 25 + 25 + 71
25 + 25 + 25 + 35 + 35
25 + 25 + 25 + 35 + 50
25 + 25 + 25 + 35 + 60
25 + 25 + 25 + 35 + 71
25 + 25 + 25 + 50 + 50
25 + 25 + 25 + 50 + 60
25 + 25 + 35 + 35 + 35
25 + 25 + 35 + 35 + 50
25 + 25 + 35 + 35 + 60
25 + 25 + 35 + 50 + 50
25 + 35 + 35 + 35 + 35
25 + 35 + 35 + 35 + 50
35 + 35 + 35 + 35 + 35

1.75 / 2.00
1.60 / 1.83
1.51 / 1.73
2.50 / 2.86
2.50 / 2.85
2.33 / 2.67
2.19 / 2.50
2.05 / 2.34
2.41 / 2.76
2.19 / 2.50
2.06 / 2.35
1.93 / 2.21
2.00 / 2.29
1.89 / 2.16
2.26 / 2.58
2.06 / 2.35
1.94 / 2.22
1.89 / 2.16
2.12 / 2.42
1.94 / 2.22
2.80 / 3.20

3.06 / 3.50
2.80 / 3.20
2.65 / 3.03
2.50 / 2.86
2.50 / 2.85
2.33 / 2.67
2.19 / 2.50
2.05 / 2.34
2.41 / 2.76
2.19 / 2.50
2.06 / 2.35
1.93 / 2.21
2.00 / 2.29
1.89 / 2.16
2.26 / 2.58
2.06 / 2.35
1.94 / 2.22
1.89 / 2.16
2.97 / 3.39
2.72 / 3.11
2.80 / 3.20

3.06 / 3.50
2.80 / 3.20
2.65 / 3.03
2.50 / 2.86
2.50 / 2.85
2.33 / 2.67
2.19 / 2.50
2.05 / 2.34
2.41 / 2.76
2.19 / 2.50
2.06 / 2.35
1.93 / 2.21
2.00 / 2.29
1.89 / 2.16
3.16 / 3.61
2.88 / 3.29
2.72 / 3.11
2.65 / 3.03
2.97 / 3.39
2.72 / 3.11
2.80 / 3.20

3.06 / 3.50
2.80 / 3.20
2.65 / 3.03
2.50 / 2.86
2.50 / 2.85
2.33 / 2.67
2.19 / 2.50
2.05 / 2.34
2.41 / 2.76
3.06 / 3.50
2.88 / 3.29
2.71 / 3.09
4.00 / 4.56
3.78 / 4.32
3.16 / 3.61
2.88 / 3.29
2.72 / 3.11
3.78 / 4.32
2.97 / 3.39
2.72 / 3.11
2.80 / 3.20

3.06 / 3.50
4.00 / 4.57
4.54 / 5.18
2.50 / 2.86
3.50 / 3.99
4.67 / 5.32
5.24 / 6.00
5.80 / 6.64
3.38 / 3.86
4.37 / 5.00
4.94 / 5.65
5.49 / 6.28
4.00 / 4.56
4.54 / 5.19
3.16 / 3.61
4.12 / 4.71
4.67 / 5.33
3.78 / 4.32
2.97 / 3.39
3.89 / 4.44
2.80 / 3.20

6 ROOMS
20 + 20 + 20 + 20 + 20 + 20
20 + 20 + 20 + 20 + 20 + 25
20 + 20 + 20 + 20 + 20 + 35
20 + 20 + 20 + 20 + 20 + 50
20 + 20 + 20 + 20 + 20 + 60
20 + 20 + 20 + 20 + 20 + 71
20 + 20 + 20 + 20 + 25 + 25
20 + 20 + 20 + 20 + 25 + 35
20 + 20 + 20 + 20 + 25 + 50
20 + 20 + 20 + 20 + 25 + 60
20 + 20 + 20 + 20 + 25 + 71
20 + 20 + 20 + 20 + 35 + 35
20 + 20 + 20 + 20 + 35 + 50
20 + 20 + 20 + 20 + 35 + 60
20 + 20 + 20 + 20 + 50 + 50
20 + 20 + 20 + 25 + 25 + 25
20 + 20 + 20 + 25 + 25 + 35
20 + 20 + 20 + 25 + 25 + 50
20 + 20 + 20 + 25 + 25 + 60
20 + 20 + 20 + 25 + 25 + 71
20 + 20 + 20 + 25 + 35 + 35
20 + 20 + 20 + 25 + 35 + 50

2.00 / 2.28
2.00 / 2.29
2.00 / 2.28
1.87 / 2.13
1.75 / 2.00
1.64 / 1.87
2.00 / 2.29
2.00 / 2.28
1.81 / 2.06
1.70 / 1.94
1.59 / 1.82
1.87 / 2.13
1.70 / 1.94
1.60 / 1.83
1.56 / 1.78
2.00 / 2.28
1.93 / 2.21
1.75 / 2.00
1.65 / 1.88
1.55 / 1.77
1.81 / 2.06
1.65 / 1.88

2.00 / 2.28
2.00 / 2.29
2.00 / 2.28
1.87 / 2.13
1.75 / 2.00
1.64 / 1.87
2.00 / 2.29
2.00 / 2.28
1.81 / 2.06
1.70 / 1.94
1.59 / 1.82
1.87 / 2.13
1.70 / 1.94
1.60 / 1.83
1.56 / 1.78
2.00 / 2.28
1.93 / 2.21
1.75 / 2.00
1.65 / 1.88
1.55 / 1.77
1.81 / 2.06
1.65 / 1.88

2.00 / 2.28
2.00 / 2.29
2.00 / 2.28
1.87 / 2.13
1.75 / 2.00
1.64 / 1.87
2.00 / 2.29
2.00 / 2.28
1.81 / 2.06
1.70 / 1.94
1.59 / 1.82
1.87 / 2.13
1.70 / 1.94
1.60 / 1.83
1.56 / 1.78
2.00 / 2.28
1.93 / 2.21
1.75 / 2.00
1.65 / 1.88
1.55 / 1.77
1.81 / 2.06
1.65 / 1.88

2.00 / 2.28
2.00 / 2.29
2.00 / 2.28
1.87 / 2.13
1.75 / 2.00
1.64 / 1.87
2.00 / 2.29
2.00 / 2.28
1.81 / 2.06
1.70 / 1.94
1.59 / 1.82
1.87 / 2.13
1.70 / 1.94
1.60 / 1.83
1.56 / 1.78
2.50 / 2.85
2.41 / 2.76
2.19 / 2.50
2.06 / 2.35
1.93 / 2.21
2.25 / 2.58
2.06 / 2.35

2.00 / 2.28
2.00 / 2.29
2.00 / 2.28
1.87 / 2.13
1.75 / 2.00
1.64 / 1.87
2.50 / 2.86
2.50 / 2.86
2.25 / 2.58
2.12 / 2.42
1.99 / 2.27
3.26 / 3.73
2.97 / 3.39
2.80 / 3.20
3.88 / 4.44
2.50 / 2.85
2.41 / 2.76
2.19 / 2.50
2.06 / 2.35
1.93 / 2.21
3.16 / 3.61
2.88 / 3.29

Unit F

Unit G

Unit H

Unit B

Unit C

Unit D

Unit E

Unit F

Unit G

25 + 25 + 25 + 25 + 25 + 25 + 25
25 + 25 + 25 + 25 + 25 + 25 + 35

2.00 / 2.28 2.00 / 2.28 2.00 / 2.28 2.00 / 2.28 2.00 / 2.28 2.00 / 2.28 2.00 / 2.28
1.89 / 2.16 1.89 / 2.16 1.89 / 2.16 1.89 / 2.16 1.89 / 2.16 1.89 / 2.16 2.65 / 3.03

8 ROOMS
20 + 20 + 20 + 20 + 20 + 20 + 20 + 25
20 + 20 + 20 + 20 + 20 + 20 + 20 + 35
20 + 20 + 20 + 20 + 20 + 20 + 25 + 25
20 + 20 + 20 + 20 + 20 + 20 + 25 + 35
20 + 20 + 20 + 20 + 20 + 25 + 25 + 25
20 + 20 + 20 + 20 + 20 + 25 + 25 + 35

1.70 / 1.94
1.60 / 1.83
1.65 / 1.88
1.56 / 1.78
1.60 / 1.83
1.51 / 1.73

1.70 / 1.94
1.60 / 1.83
1.65 / 1.88
1.56 / 1.78
1.60 / 1.83
1.51 / 1.73

1.70 / 1.94
1.60 / 1.83
1.65 / 1.88
1.56 / 1.78
1.60 / 1.83
1.51 / 1.73

1.70 / 1.94
1.60 / 1.83
1.65 / 1.88
1.56 / 1.78
1.60 / 1.83
1.51 / 1.73

Unit H

1.70 / 1.94
1.60 / 1.83
1.65 / 1.88
1.56 / 1.78
1.60 / 1.83
1.51 / 1.73

1.70 / 1.94
1.60 / 1.83
1.65 / 1.88
1.56 / 1.78
2.00 / 2.28
1.89 / 2.16

1.70 / 1.94
1.60 / 1.83
2.05 / 2.35
1.93 / 2.22
2.00 / 2.28
1.89 / 2.16

2.10 / 2.42
2.80 / 3.19
2.05 / 2.35
2.71 / 3.10
2.00 / 2.28
2.65 / 3.03

Unit E

Unit F

Unit G

Unit H

MXZ-8B160yA
1 OUTDOOR UNIT
Indoor Unit
Combination

2.00 / 2.28
2.50 / 2.85
3.50 / 3.99
4.65 / 5.33
5.25 / 6.00
5.80 / 6.64
2.50 / 2.86
3.50 / 4.00
4.51 / 5.16
5.08 / 5.82
5.65 / 6.45
3.26 / 3.73
4.23 / 4.85
4.80 / 5.48
3.88 / 4.44
2.50 / 2.85
3.38 / 3.85
4.37 / 5.00
4.93 / 5.65
5.49 / 6.27
3.16 / 3.61
4.11 / 4.70

UPTO 8 INDOOR UNITS


Cooling / Heating Capacity (kW)
Unit A

1 ROOM
20
25
35
50
60
71
100

2.00 / 2.20
2.50 / 3.60
3.50 / 4.00
5.00 / 7.20
6.00 / 7.90
7.10 / 8.60
10.0 / 11.2

2 ROOMS
20 + 20
20 + 25
20 + 35
20 + 50
20 + 60
20 + 71
20 + 100
25 + 25
25 + 35
25 + 50
25 + 60
25 + 71
25 + 100
35 + 35
35 + 50
35 + 60
35 + 71
35 + 100
50 + 50

2.00 / 2.30
2.00 / 2.31
2.00 / 2.29
2.00 / 2.31
2.00 / 2.33
2.00 / 2.33
2.00 / 2.32
2.50 / 2.85
2.50 / 2.88
2.50 / 2.90
2.50 / 2.91
2.50 / 2.89
2.50 / 2.90
3.50 / 4.05
3.50 / 4.08
3.50 / 4.02
3.50 / 4.00
3.50 / 4.07
5.00 / 5.80

Unit B

2.00 / 2.30
2.50 / 2.89
3.50 / 4.01
5.00 / 5.79
6.00 / 6.98
7.10 / 8.27
10.00 / 11.58
2.50 / 2.85
3.50 / 4.02
5.00 / 5.80
6.00 / 6.99
7.10 / 8.21
10.0 / 11.60
3.50 / 4.05
5.00 / 5.82
6.00 / 6.88
7.10 / 8.10
10.0 / 11.63
5.00 / 5.80

Unit C

Unit D

20 + 20 + 20 + 25 + 35 + 60
20 + 20 + 20 + 25 + 50 + 50
20 + 20 + 20 + 35 + 35 + 35
20 + 20 + 20 + 35 + 35 + 50
20 + 20 + 25 + 25 + 25 + 25
20 + 20 + 25 + 25 + 25 + 35
20 + 20 + 25 + 25 + 25 + 50
20 + 20 + 25 + 25 + 25 + 60
20 + 20 + 25 + 25 + 35 + 35
20 + 20 + 25 + 25 + 35 + 50
20 + 20 + 25 + 25 + 35 + 60
20 + 20 + 25 + 35 + 35 + 35
20 + 20 + 25 + 35 + 35 + 50
20 + 20 + 35 + 35 + 35 + 35
20 + 25 + 25 + 25 + 25 + 25
20 + 25 + 25 + 25 + 25 + 35
20 + 25 + 25 + 25 + 25 + 50
20 + 25 + 25 + 25 + 25 + 60
20 + 25 + 25 + 25 + 35 + 35
20 + 25 + 25 + 25 + 35 + 50
20 + 25 + 25 + 35 + 35 + 35
20 + 25 + 35 + 35 + 35 + 35
25 + 25 + 25 + 25 + 25 + 25
25 + 25 + 25 + 25 + 25 + 35
25 + 25 + 25 + 25 + 25 + 50
25 + 25 + 25 + 25 + 25 + 60
25 + 25 + 25 + 25 + 35 + 35
25 + 25 + 25 + 25 + 35 + 50
25 + 25 + 25 + 35 + 35 + 35

1.56 / 1.78
1.51 / 1.73
1.70 / 1.94
1.56 / 1.78
2.00 / 2.28
1.87 / 2.13
1.70 / 1.94
1.60 / 1.83
1.75 / 2.00
1.60 / 1.83
1.51 / 1.73
1.65 / 1.88
1.51 / 1.73
1.56 / 1.78
1.93 / 2.20
1.81 / 2.06
1.65 / 1.88
1.56 / 1.78
1.70 / 1.94
1.56 / 1.78
1.60 / 1.83
1.51 / 1.73
2.33 / 2.66
2.19 / 2.50
2.00 / 2.28
1.89 / 2.16
2.06 / 2.35
1.89 / 2.16
1.94 / 2.22

1.56 / 1.78
1.51 / 1.73
1.70 / 1.94
1.56 / 1.78
2.00 / 2.28
1.87 / 2.13
1.70 / 1.94
1.60 / 1.83
1.75 / 2.00
1.60 / 1.83
1.51 / 1.73
1.65 / 1.88
1.51 / 1.73
1.56 / 1.78
2.41 / 2.76
2.26 / 2.58
2.06 / 2.35
1.94 / 2.22
2.12 / 2.42
1.94 / 2.22
2.00 / 2.28
1.89 / 2.15
2.33 / 2.66
2.19 / 2.50
2.00 / 2.28
1.89 / 2.16
2.06 / 2.35
1.89 / 2.16
1.94 / 2.22

1.56 / 1.78
1.51 / 1.73
1.70 / 1.94
1.56 / 1.78
2.50 / 2.86
2.33 / 2.67
2.12 / 2.42
2.00 / 2.28
2.19 / 2.50
2.00 / 2.28
1.89 / 2.16
2.06 / 2.35
1.89 / 2.16
2.72 / 3.11
2.41 / 2.76
2.26 / 2.58
2.06 / 2.35
1.94 / 2.22
2.12 / 2.42
1.94 / 2.22
2.00 / 2.28
2.65 / 3.03
2.33 / 2.66
2.19 / 2.50
2.00 / 2.28
1.89 / 2.16
2.06 / 2.35
1.89 / 2.16
1.94 / 2.22

1.94 / 2.22
1.89 / 2.16
2.96 / 3.39
2.72 / 3.11
2.50 / 2.86
2.33 / 2.67
2.12 / 2.42
2.00 / 2.28
2.19 / 2.50
2.00 / 2.28
1.89 / 2.16
2.88 / 3.29
2.65 / 3.03
2.72 / 3.11
2.41 / 2.76
2.26 / 2.58
2.06 / 2.35
1.94 / 2.22
2.12 / 2.42
1.94 / 2.22
2.80 / 3.20
2.65 / 3.03
2.33 / 2.66
2.19 / 2.50
2.00 / 2.28
1.89 / 2.16
2.06 / 2.35
1.89 / 2.16
2.72 / 3.11

2.72 / 3.11
3.78 / 4.32
2.96 / 3.39
2.72 / 3.11
2.50 / 2.86
2.33 / 2.67
2.12 / 2.42
2.00 / 2.28
3.06 / 3.50
2.80 / 3.20
2.65 / 3.03
2.88 / 3.29
2.65 / 3.03
2.72 / 3.11
2.41 / 2.76
2.26 / 2.58
2.06 / 2.35
1.94 / 2.22
2.97 / 3.39
2.72 / 3.11
2.80 / 3.20
2.65 / 3.03
2.33 / 2.66
2.19 / 2.50
2.00 / 2.28
1.89 / 2.16
2.88 / 3.29
2.65 / 3.03
2.72 / 3.11

4.66 / 5.33
3.78 / 4.32
2.96 / 3.39
3.88 / 4.44
2.50 / 2.86
3.27 / 3.73
4.24 / 4.85
4.80 / 5.48
3.06 / 3.50
4.00 / 4.57
4.54 / 5.19
2.88 / 3.29
3.78 / 4.32
2.72 / 3.11
2.41 / 2.76
3.15 / 3.61
4.11 / 4.70
4.67 / 5.33
2.97 / 3.39
3.89 / 4.44
2.80 / 3.20
2.65 / 3.03
2.33 / 2.66
3.05 / 3.50
4.00 / 4.57
4.54 / 5.19
2.88 / 3.29
3.78 / 4.32
2.72 / 3.11

7 ROOMS
20 + 20 + 20 + 20 + 20 + 20 + 20
20 + 20 + 20 + 20 + 20 + 20 + 25
20 + 20 + 20 + 20 + 20 + 20 + 35
20 + 20 + 20 + 20 + 20 + 20 + 50
20 + 20 + 20 + 20 + 20 + 20 + 60
20 + 20 + 20 + 20 + 20 + 25 + 25
20 + 20 + 20 + 20 + 20 + 25 + 35
20 + 20 + 20 + 20 + 20 + 25 + 50
20 + 20 + 20 + 20 + 20 + 25 + 60
20 + 20 + 20 + 20 + 20 + 35 + 35
20 + 20 + 20 + 20 + 20 + 35 + 50
20 + 20 + 20 + 20 + 25 + 25 + 25
20 + 20 + 20 + 20 + 25 + 25 + 35
20 + 20 + 20 + 20 + 25 + 25 + 50
20 + 20 + 20 + 20 + 25 + 35 + 35
20 + 20 + 20 + 20 + 35 + 35 + 35
20 + 20 + 20 + 25 + 25 + 25 + 25
20 + 20 + 20 + 25 + 25 + 25 + 35
20 + 20 + 20 + 25 + 25 + 25 + 50
20 + 20 + 20 + 25 + 25 + 35 + 35
20 + 20 + 25 + 25 + 25 + 25 + 25
20 + 20 + 25 + 25 + 25 + 25 + 35
20 + 20 + 25 + 25 + 25 + 35 + 35
20 + 25 + 25 + 25 + 25 + 25 + 25
20 + 25 + 25 + 25 + 25 + 25 + 35

2.00 / 2.28
1.93 / 2.21
1.81 / 2.06
1.65 / 1.88
1.56 / 1.78
1.87 / 2.13
1.75 / 2.00
1.60 / 1.83
1.51 / 1.73
1.65 / 1.88
1.51 / 1.73
1.81 / 2.06
1.70 / 1.94
1.56 / 1.78
1.60 / 1.83
1.51 / 1.73
1.74 / 2.00
1.65 / 1.88
1.51 / 1.73
1.56 / 1.78
1.70 / 1.94
1.60 / 1.83
1.51 / 1.73
1.64 / 1.88
1.56 / 1.78

2.00 / 2.28
1.93 / 2.21
1.81 / 2.06
1.65 / 1.88
1.56 / 1.78
1.87 / 2.13
1.75 / 2.00
1.60 / 1.83
1.51 / 1.73
1.65 / 1.88
1.51 / 1.73
1.81 / 2.06
1.70 / 1.94
1.56 / 1.78
1.60 / 1.83
1.51 / 1.73
1.74 / 2.00
1.65 / 1.88
1.51 / 1.73
1.56 / 1.78
1.70 / 1.94
1.60 / 1.83
1.51 / 1.73
2.06 / 2.35
1.94 / 2.22

2.00 / 2.28
1.93 / 2.21
1.81 / 2.06
1.65 / 1.88
1.56 / 1.78
1.87 / 2.13
1.75 / 2.00
1.60 / 1.83
1.51 / 1.73
1.65 / 1.88
1.51 / 1.73
1.81 / 2.06
1.70 / 1.94
1.56 / 1.78
1.60 / 1.83
1.51 / 1.73
1.74 / 2.00
1.65 / 1.88
1.51 / 1.73
1.56 / 1.78
2.12 / 2.42
2.00 / 2.28
1.89 / 2.16
2.06 / 2.35
1.94 / 2.22

2.00 / 2.28
1.93 / 2.21
1.81 / 2.06
1.65 / 1.88
1.56 / 1.78
1.87 / 2.13
1.75 / 2.00
1.60 / 1.83
1.51 / 1.73
1.65 / 1.88
1.51 / 1.73
1.81 / 2.06
1.70 / 1.94
1.56 / 1.78
1.60 / 1.83
1.51 / 1.73
2.19 / 2.50
2.06 / 2.35
1.89 / 2.16
1.94 / 2.22
2.12 / 2.42
2.00 / 2.28
1.89 / 2.16
2.06 / 2.35
1.94 / 2.22

2.00 / 2.28
1.93 / 2.21
1.81 / 2.06
1.65 / 1.88
1.56 / 1.78
1.87 / 2.13
1.75 / 2.00
1.60 / 1.83
1.51 / 1.73
1.65 / 1.88
1.51 / 1.73
2.25 / 2.58
2.12 / 2.42
1.94 / 2.22
2.00 / 2.28
2.65 / 3.02
2.19 / 2.50
2.06 / 2.35
1.89 / 2.16
1.94 / 2.22
2.12 / 2.42
2.00 / 2.28
1.89 / 2.16
2.06 / 2.35
1.94 / 2.22

2.00 / 2.28
1.93 / 2.21
1.81 / 2.06
1.65 / 1.88
1.56 / 1.78
2.32 / 2.67
2.19 / 2.50
2.00 / 2.28
1.89 / 2.16
2.87 / 3.29
2.65 / 3.03
2.25 / 2.58
2.12 / 2.42
1.94 / 2.22
2.80 / 3.20
2.65 / 3.02
2.19 / 2.50
2.06 / 2.35
1.89 / 2.16
2.72 / 3.11
2.12 / 2.42
2.00 / 2.28
2.65 / 3.03
2.06 / 2.35
1.94 / 2.22

Air Conditioning
1.4.23 1.121

2.00 / 2.28
2.41 / 2.74
3.14 / 3.61
4.10 / 4.70
4.64 / 5.32
2.32 / 2.67
2.19 / 2.50
4.00 / 4.57
4.54 / 5.19
2.87 / 3.29
3.78 / 4.32
2.25 / 2.58
2.96 / 3.39
3.88 / 4.44
2.80 / 3.20
2.65 / 3.02
2.19 / 2.50
2.87 / 3.29
3.78 / 4.32
2.72 / 3.11
2.12 / 2.42
2.80 / 3.20
2.65 / 3.03
2.06 / 2.35
2.72 / 3.11

50 + 60
50 + 71
50 + 100
60 + 60
60 + 71
60 + 100
71 + 71
71 + 100
100 + 100

5.00 / 5.82 6.00 / 6.98


3.97 / 5.83 5.63 / 8.27
5.00 / 5.80 10.00 / 11.60
6.00 / 6.95 6.00 / 6.95
6.00 / 6.87 7.10 / 8.13
6.00 / 6.75 10.0 / 11.25
7.00 / 8.25 7.00 / 8.25
7.10 / 7.47 10.0 / 10.53
10.00 / 9.00 10.00 / 9.00

3 ROOMS
20 + 20 +20
20 + 20 + 25
20 + 20 + 35
20 + 20 + 50
20 + 20 + 60
20 + 20 + 71
20 + 20 + 100
20 + 25 + 25
20 + 25 + 35
20 + 25 + 50
20 + 25 + 60
20 + 25 + 71
20 + 35 + 35
20 + 35 + 50
20 + 35 + 60
20 + 35 + 71
20 + 50 + 50
20 + 50 + 60
20 + 50 +71
20 + 60 + 60
20 + 60 + 71
20 + 71 + 71
25 + 25 + 25
25 + 25 + 35
25 + 25 + 50
25 + 25 + 60
25 + 25 + 71
25 + 25 + 100
25 + 35 + 35
25 + 35 + 50
25 + 35 + 60
25 + 35 + 71
25 + 50 + 50
25 + 50 + 60
25 + 50 + 71
25 + 60 + 60
25 + 60 + 71
25 + 71 + 71
35 + 35 + 35
35 + 35 + 50
35 + 35 + 60
35 + 35 + 71
35 + 50 + 50
35 + 50 + 60
35 + 50 + 71

2.00 / 2.33
2.00 / 2.31
2.00 / 2.32
2.00 / 2.33
2.00 / 2.32
2.00 / 2.32
2.00 / 2.33
2.00 / 2.31
2.00 / 2.33
2.00 / 2.32
2.00 / 2.32
2.00 / 2.33
2.00 / 2.33
2.00 / 2.32
2.00 / 2.33
2.00 / 2.32
2.00 / 2.32
2.00 / 2.32
1.99 / 2.33
2.00 / 2.33
2.00 / 2.12
1.91 / 2.22
2.50 / 2.90
2.50 / 2.91
2.50 / 2.90
2.50 / 2.91
2.50 / 2.91
2.50 / 2.90
2.50 / 2.89
2.50 / 2.91
2.50 / 2.90
2.50 / 2.90
2.50 / 2.91
2.50 / 2.91
2.50 / 2.91
2.50 / 2.90
2.48 / 2.56
2.32 / 2.69
3.50 / 4.07
3.50 / 4.05
3.50 / 4.07
3.50 / 4.07
3.50 / 4.07
3.50 / 4.06
3.48 / 4.04

2.00 / 2.33
2.00 / 2.31
2.00 / 2.32
2.00 / 2.33
2.00 / 2.32
2.00 / 2.32
2.00 / 2.33
2.50 / 2.89
2.50 / 2.91
2.50 / 2.91
2.50 / 2.90
2.50 / 2.91
3.50 / 4.08
3.50 / 4.07
3.50 / 4.08
3.50 / 4.06
5.00 / 5.79
5.00 / 5.81
4.96 / 5.82
6.00 / 6.99
6.00 / 6.36
6.79 / 7.89
2.50 / 2.90
2.50 / 2.91
2.50 / 2.90
2.50 / 2.91
2.50 / 2.91
2.50 / 2.90
3.50 / 4.05
3.50 / 4.07
3.50 / 4.05
3.50 / 4.06
5.00 / 5.80
5.00 / 5.81
5.00 / 5.82
6.00 / 6.62
5.96 / 6.15
6.59 / 7.65
3.50 / 4.07
3.50 / 4.05
3.50 / 4.07
3.50 / 4.07
5.00 / 5.81
5.00 / 5.79
4.97 / 5.77

2.00 / 2.33
2.50 / 2.88
3.50 / 4.06
5.00 / 5.83
6.00 / 6.96
7.10 / 8.25
10.0 / 11.64
2.50 / 2.89
3.50 / 4.07
5.00 / 5.79
6.00 / 6.97
7.10 / 8.26
3.50 / 4.08
5.00 / 5.81
6.00 / 6.99
7.10 / 8.23
5.00 / 5.79
6.00 / 6.97
7.05 / 8.26
6.00 / 6.99
7.10 / 7.52
6.79 / 7.89
2.50 / 2.90
3.50 / 4.08
5.00 / 5.80
6.00 / 6.98
7.10 / 8.27
10.00 / 11.60
3.50 / 4.05
5.00 / 5.82
6.00 / 6.95
7.10 / 8.24
5.00 / 5.80
6.00 / 6.98
7.10 / 8.27
6.00 / 6.62
7.05 / 7.28
6.59 / 7.65
3.50 / 4.07
5.00 / 5.79
6.00 / 6.97
7.05 / 8.26
5.00 / 5.81
6.00 / 6.95
7.05 / 8.19

The Flexible & Efficient Multi-Split Range

1.4.24

Multi-Split Combinations
MXZ-8B160yA
1 OUTDOOR UNIT
Indoor Unit
Combination

35 + 50 + 100
35 + 60 + 60
35 + 60 + 71
35 + 60 + 100
35 + 71 + 71
50 + 50 + 50
50 + 50 + 60
50 + 50 + 71
50 + 50 + 100
50 + 60 + 60
60 + 60 + 60
60 + 60 + 71
60 + 71 + 71
4 ROOMS
20 + 20 + 20 + 20
20 + 20 + 20 + 25
20 + 20 + 20 + 35
20 + 20 + 20 + 50
20 + 20 + 20 + 60
20 + 20 + 20 + 71
20 + 20 + 20 + 100
20 + 20 + 25 + 25
20 + 20 + 25 + 35
20 + 20 + 25 + 50
20 + 20 + 25 + 60
20 + 20 + 25 + 71
20 + 20 + 25 + 100
20 + 20 + 35 + 35
20 + 20 + 35 + 50
20 + 20 + 35 + 60
20 + 20 + 35 + 71
20 + 20 + 35 + 100
20 + 20 + 50 + 50
20 + 20 + 50 + 60
20 + 20 + 50 + 71
20 + 20 + 60 + 60
20 + 20 + 60 + 71
20 + 20 + 60 + 100
20 + 20 + 71 + 71
20 + 25 + 25 + 25
20 + 25 + 25 + 35
20 + 25 + 25 + 50
20 + 25 + 25 + 60
20 + 25 + 25 + 71

Indoor Unit
Combination

UPTO 8 INDOOR UNITS

Unit A

Unit B

Unit C

Unit D

25 + 50 + 50 + 50
25 + 50 + 50 + 60
35 + 35 + 35 + 35
35 + 35 + 35 + 50
35 + 35 + 35 + 60
35 + 35 + 35 + 71
35 + 35 + 50 + 50
35 + 35 + 50 + 60
35 + 35 + 50 + 71
35 + 35 + 60 + 60
35 + 35 + 60 + 71
35 + 50 + 50 + 50
35 + 50 + 50 + 60
50 + 50 + 50 + 50

2.21 / 2.57
2.09 / 2.43
3.50 / 4.08
3.16 / 4.06
3.29 / 3.82
3.08 / 3.58
3.19 / 3.71
3.01 / 3.50
2.84 / 3.30
2.86 / 3.32
2.70 / 3.13
2.65 / 3.41
2.78 / 3.23
3.88 / 4.50

4.43 / 5.14
4.19 / 4.86
3.50 / 4.08
3.16 / 4.06
3.29 / 3.82
3.08 / 3.58
3.19 / 3.71
3.01 / 3.50
2.84 / 3.30
2.86 / 3.32
2.70 / 3.13
3.78 / 4.86
3.97 / 4.62
3.88 / 4.50

4.43 / 5.14
4.19 / 4.86
3.50 / 4.08
3.16 / 4.06
3.29 / 3.82
3.08 / 3.58
4.56 / 5.29
4.31 / 5.00
4.06 / 4.71
4.89 / 5.68
4.63 / 5.37
3.78 / 4.86
3.97 / 4.62
3.88 / 4.50

4.43 / 5.14
5.03 / 5.84
3.50 / 4.08
4.52 / 5.81
5.64 / 6.55
6.25 / 7.26
4.56 / 5.29
4.31 / 5.00
5.76 / 6.69
4.89 / 5.68
5.40 / 6.36
3.78 / 4.86
4.77 / 5.54
3.88 / 4.50

5 ROOMS
20 + 20 + 20 + 20 + 20
20 + 20 + 20 + 20 + 25
20 + 20 + 20 + 20 + 35
20 + 20 + 20 + 20 + 50
20 + 20 + 20 + 20 + 60
20 + 20 + 20 + 20 + 71
20 + 20 + 20 + 20 + 100
20 + 20 + 20 + 25 + 25
20 + 20 + 20 + 25 + 35
20 + 20 + 20 + 25 + 50
20 + 20 + 20 + 25 + 60
20 + 20 + 20 + 25 + 71
20 + 20 + 20 + 25 + 100
20 + 20 + 20 + 35 + 35
20 + 20 + 20 + 35 + 50
20 + 20 + 20 + 35 + 60
20 + 20 + 20 + 35 + 71
20 + 20 + 20 + 35 + 100
20 + 20 + 20 + 50 + 50
20 + 20 + 20 + 50 + 60
20 + 20 + 20 + 50 + 71
20 + 20 + 20 + 60 + 60
20 + 20 + 20 + 60 + 71
20 + 20 + 20 + 71 + 71
20 + 20 + 25 + 25 + 25
20 + 20 + 25 + 25 + 35
20 + 20 + 25 + 25 + 50
20 + 20 + 25 + 25 + 60
20 + 20 + 25 + 25 + 71
20 + 20 + 25 + 35 + 35
20 + 20 + 25 + 35 + 50

2.00 / 2.32
2.00 / 2.32
2.00 / 2.33
2.00 / 2.32
2.00 / 2.33
2.00 / 2.32
1.72 / 2.00
2.00 / 2.33
2.00 / 2.32
2.00 / 2.33
2.00 / 2.32
1.99 / 2.31
1.68 / 1.95
2.00 / 2.32
2.00 / 2.32
2.00 / 2.32
1.87 / 2.17
1.59 / 1.85
1.94 / 2.25
1.82 / 2.12
1.71 / 1.99
1.72 / 2.00
1.62 / 1.88
1.53 / 1.78
2.00 / 2.33
2.00 / 2.32
2.00 / 2.33
2.00 / 2.32
1.93 / 2.24
2.00 / 2.33
2.00 / 2.32

2.00 / 2.32
2.00 / 2.32
2.00 / 2.33
2.00 / 2.32
2.00 / 2.33
2.00 / 2.32
1.72 / 2.00
2.00 / 2.33
2.00 / 2.32
2.00 / 2.33
2.00 / 2.32
1.99 / 2.31
1.68 / 1.95
2.00 / 2.32
2.00 / 2.32
2.00 / 2.32
1.87 / 2.17
1.59 / 1.85
1.94 / 2.25
1.82 / 2.12
1.71 / 1.99
1.72 / 2.00
1.62 / 1.88
1.53 / 1.78
2.00 / 2.33
2.00 / 2.32
2.00 / 2.33
2.00 / 2.32
1.93 / 2.24
2.00 / 2.33
2.00 / 2.32

2.00 / 2.32
2.00 / 2.32
2.00 / 2.33
2.00 / 2.32
2.00 / 2.33
2.00 / 2.32
1.72 / 2.00
2.00 / 2.33
2.00 / 2.32
2.00 / 2.33
2.00 / 2.32
1.99 / 2.31
1.68 / 1.95
2.00 / 2.32
2.00 / 2.32
2.00 / 2.32
1.87 / 2.17
1.59 / 1.85
1.94 / 2.25
1.82 / 2.12
1.71 / 1.99
1.72 / 2.00
1.62 / 1.88
1.53 / 1.78
2.50 / 2.91
2.50 / 2.90
2.50 / 2.91
2.50 / 2.90
2.41 / 2.80
2.50 / 2.91
2.50 / 2.90

2.00 / 2.32
2.00 / 2.32
2.00 / 2.33
2.00 / 2.32
2.00 / 2.33
2.00 / 2.32
1.72 / 2.00
2.50 / 2.91
2.50 / 2.90
2.50 / 2.91
2.41 / 2.90
2.48 / 2.88
2.09 / 2.43
3.50 / 4.07
3.50 / 4.06
3.50 / 4.06
3.27 / 3.80
2.78 / 3.23
4.84 / 5.63
4.56 / 5.29
4.28 / 4.97
5.17 / 6.00
4.87 / 5.65
5.45 / 6.33
2.50 / 2.91
2.50 / 2.90
2.50 / 2.91
2.50 / 2.90
2.41 / 2.80
3.50 / 4.07
3.50 / 4.06

Cooling / Heating Capacity (kW)


Unit A

Unit B

Unit C

2.93 / 3.41
3.50 / 4.06
3.27 / 3.80
2.78 / 3.23
3.06 / 3.56
5.00 / 5.80
4.84 / 5.63
4.53 / 5.26
3.88 / 4.50
4.56 / 5.29
5.17 / 6.00
4.87 / 5.65
4.60 / 5.35

4.19 / 4.86
6.00 / 6.97
5.60 / 6.51
4.77 / 5.54
6.22 / 7.22
5.00 / 5.80
4.84 / 5.63
4.53 / 5.26
3.88 / 4.50
5.47 / 6.35
5.17 / 6.00
4.87 / 5.65
5.45 / 6.33

8.38 / 9.73
6.00 / 6.97
6.63 / 7.70
7.95 / 9.23
6.22 / 7.22
5.00 / 5.80
5.81 / 6.75
6.44 / 7.47
7.75 / 9.00
5.47 / 6.35
5.17 / 6.00
5.76 / 6.69
5.45 / 6.33

2.00 / 2.33
2.00 / 2.33
2.00 / 2.32
2.00 / 2.33
2.00 / 2.32
2.00 / 2.32
1.94 / 2.25
2.00 / 2.33
2.00 / 2.32
2.00 / 2.33
2.00 / 2.32
2.00 / 2.32
1.88 / 2.33
2.00 / 2.33
2.00 / 2.32
2.00 / 2.33
2.00 / 2.33
1.77 / 2.06
2.00 / 2.33
1.87 / 2.32
1.93 / 2.24
1.94/ 2.25
1.81 / 2.11
1.55 / 1.80
1.70 / 1.98
2.00 / 2.32
2.00 / 2.32
2.00 / 2.32
2.00 / 2.32
2.00 / 2.33

2.00 / 2.33
2.00 / 2.33
2.00 / 2.32
2.00 / 2.33
2.00 / 2.32
2.00 / 2.32
1.94 / 2.25
2.00 / 2.33
2.00 / 2.32
2.00 / 2.33
2.00 / 2.32
2.00 / 2.32
1.88 / 2.33
2.00 / 2.33
2.00 / 2.32
2.00 / 2.33
2.00 / 2.33
1.77 / 2.06
2.00 / 2.33
1.87 / 2.32
1.93 / 2.24
1.94/ 2.25
1.81 / 2.11
1.55 / 1.80
1.70 / 1.98
2.50 / 2.89
2.50 / 2.90
2.50 / 2.90
2.50 / 2.90
2.50 / 2.91

2.00 / 2.33
2.00 / 2.33
2.00 / 2.32
2.00 / 2.33
2.00 / 2.32
2.00 / 2.32
1.94 / 2.25
2.00 / 2.92
2.50 / 2.90
2.50 / 2.91
2.50 / 2.91
2.50 / 2.90
1.88 / 2.33
3.50 / 4.07
3.50 / 4.06
3.50 / 4.07
3.50 / 4.08
3.10 / 3.60
5.00 / 5.82
4.67 / 5.80
4.81 / 5.59
5.81 / 6.75
5.44 / 6.32
4.65 / 5.40
6.05 / 7.02
2.50 / 2.89
2.50 / 2.90
2.50 / 2.90
2.50 / 2.90
2.50 / 2.91

Unit D

2.00 / 2.33
2.50 / 2.91
3.50 / 4.05
5.00 / 5.82
6.00 / 6.95
7.10 / 8.24
9.69 / 11.25
2.00 / 2.92
3.50 / 4.06
5.00 / 5.83
6.00 / 5.83
7.10 / 8.25
9.39 / 10.29
3.50 / 4.07
5.00 / 5.80
5.00 / 6.98
7.10 / 8.27
8.86 / 10.29
5.00 / 5.82
4.67 / 5.80
6.84 / 7.94
5.81 / 6.75
6.44 / 7.47
7.75 / 9.00
6.05 / 7.02
2.50 / 2.89
3.50 / 4.07
5.00 / 5.79
6.00 / 6.97
7.10 / 8.26

Unit E

Unit F

Unit G

Unit H

Cooling / Heating Capacity (kW)


Unit E

2.00 / 2.32
2.50 / 2.90
3.50 / 4.08
5.00 / 5.81
6.00 / 6.99
7.10 / 8.23
8.61 / 10.00
2.50 / 2.91
3.50 / 4.05
5.00 / 5.81
5.79 / 6.95
7.05 / 8.19
8.38 / 9.73
3.50 / 4.07
5.00 / 5.79
6.00 / 6.97
6.63 / 7.70
7.95 / 9.23
4.84 / 5.63
5.47 / 6.35
6.08 / 7.06
5.17 / 6.00
5.76 / 6.69
5.45 / 6.33
2.50 / 2.91
3.50 / 4.06
5.00 / 5.82
6.00 / 6.96
6.84 / 7.94
3.50 / 4.07
5.00 / 5.80

Unit F

Unit G

Unit H

20 + 25 + 35 + 35
20 + 25 + 35 + 50
20 + 25 + 35 + 60
20 + 25 + 35 + 71
20 + 25 + 35 + 100
20 + 25 + 50 + 50
20 + 25 + 50 + 60
20 + 25 + 50 + 71
20 + 25 + 50 + 100
20 + 25 + 60 + 60
20 + 25 + 60 + 71
20 + 25 + 71 + 71
20 + 35 + 35 + 35
20 + 35 + 35 + 50
20 + 35 + 35 + 60
20 + 35 + 35 + 71
20 + 35 + 35 + 100
20 + 35 + 50 + 50
20 + 35 + 50 + 60
20 + 35 + 50 + 71
20 + 35 + 60 + 60
20 + 35 + 60 + 71
20 + 50 + 50 + 50
20 + 50 + 50 + 60
20 + 50 + 50 + 71
20 + 50 + 60 + 60
20 + 50 + 60 + 71
20 + 60 + 60 + 60
25 + 25 + 25 + 25
25 + 25 + 25 + 35
25 + 25 + 25 + 50
25 + 25 + 25 + 60
25 + 25 + 25 + 71
25 + 25 + 25 + 100
25 + 25 + 35 + 35
25 + 25 + 35 + 50
25 + 25 + 35 + 60
25 + 25 + 35 + 71
25 + 25 + 35 + 100
25 + 25 + 50 + 50
25 + 25 + 50 + 60
25 + 25 + 50 + 71
25 + 25 + 60 + 60
25 + 25 + 60 + 71
25 + 25 + 71 + 71
25 + 35 + 35 + 35
25 + 35 + 35 + 50
25 + 35 + 35 + 60
25 + 35 + 35 + 71
25 + 35 + 35 + 100
25 + 35 + 50 + 50
25 + 35 + 50 + 60
25 + 35 + 50 + 71
25 + 35 + 60 + 60
25 + 35 + 60 + 71
25 + 35 + 71 + 71

2.00 / 2.33
2.00 / 2.32
2.00 / 2.33
2.00 / 2.32
1.72 / 2.00
2.00 / 2.32
2.00 / 2.32
2.00 / 2.17
1.59 / 1.85
1.88 / 2.18
1.76 / 2.05
1.66 / 1.93
2.00 / 2.32
2.00 / 2.33
2.00 / 2.32
1.93 / 2.24
1.63 / 1.89
2.00 / 2.32
1.88 / 2.18
1.76 / 2.05
1.77 / 2.06
1.67 / 1.94
1.82 / 2.12
1.72 / 2.00
1.62 / 1.88
1.63 / 1.89
1.54 / 1.79
1.55 / 1.80
2.50 / 2.90
2.50 / 2.91
2.50 / 2.90
2.50 / 2.91
2.50 / 2.91
2.21 / 2.57
2.50 / 2.90
2.50 / 2.91
2.50 / 2.90
2.48 / 2.56
2.09 / 2.43
2.50 / 2.90
2.42 / 2.81
2.27 / 2.63
2.28 / 2.65
2.14 / 2.49
2.02 / 2.34
2.50 / 2.90
2.50 / 2.90
2.50 / 2.90
2.33 / 2.71
1.99 / 2.31
2.42 / 2.81
2.28 / 2.81
2.14 / 2.49
2.15 / 2.50
2.03 / 2.36
1.92 / 2.23

Air Conditioning
1.4.25 1.121

2.48 / 2.91
2.50 / 2.91
2.50 / 2.91
2.50 / 2.90
2.15 / 2.50
2.50 / 2.90
2.50 / 2.90
2.50 / 2.71
1.99 / 2.31
2.35 / 2.73
2.20 / 2.56
2.07 / 2.41
3.50 / 4.06
3.50 / 4.08
3.50 / 4.06
3.37 / 3.91
2.86 / 3.32
3.50 / 4.06
3.29 / 3.82
3.08 / 3.58
3.10 / 3.60
2.92 / 3.39
4.56 / 5.29
4.31 / 5.00
4.06 / 4.71
4.08 / 4.74
3.86 / 4.48
4.65 / 5.40
2.50 / 2.90
2.50 / 2.91
2.50 / 2.90
2.50 / 2.91
2.50 / 2.91
2.21 / 2.57
2.50 / 2.90
2.50 / 2.91
2.50 / 2.90
2.48 / 2.56
2.09 / 2.43
2.50 / 2.90
2.42 / 2.81
2.27 / 2.63
2.28 / 2.65
2.14 / 2.49
2.02 / 2.34
3.50 / 4.07
3.50 / 4.06
3.50 / 4.06
3.27 / 3.80
2.78 / 3.23
3.39 / 3.94
3.19 / 3.71
3.00 / 3.48
3.01 / 3.50
2.84 / 3.30
2.69 / 3.12

3.50 / 3.99
3.50 / 4.07
3.50 / 4.07
3.50 / 4.06
3.01 / 3.50
5.00 / 5.79
5.00 / 5.81
4.22 / 5.42
3.97 / 4.62
5.64 / 6.55
5.28 / 6.14
5.89 / 6.83
3.50 / 4.06
3.50 / 4.08
3.50 / 4.06
3.37/ 3.91
2.86 / 3.32
5.00 / 5.81
4.70 / 5.45
4.40 / 5.11
5.31 / 6.17
5.00 / 5.81
4.56 / 5.29
4.31 / 5.00
4.06 / 4.71
4.89 / 5.68
4.63 / 5.37
4.65 / 5.40
2.50 / 2.90
2.50 / 2.91
2.50 / 2.90
2.50 / 2.91
2.50 / 2.91
2.21 / 2.57
3.50 / 4.05
3.50 / 4.07
3.50 / 4.06
3.48 / 3.59
2.93 / 3.41
5.00 / 5.80
4.84 / 5.63
4.53 / 5.26
5.47 / 6.35
5.14 / 5.97
5.73 / 6.66
3.50 / 4.07
3.50 / 4.06
3.50 / 4.06
3.27 / 3.80
2.78 / 3.23
4.84 / 5.63
4.56 / 5.29
4.28 / 4.97
5.17 / 6.00
4.87 / 5.65
5.45 / 6.33

3.50 / 3.99
5.00 / 5.81
6.00 / 6.99
7.10 / 8.23
8.61 / 10.00
5.00 / 5.79
6.00 / 6.97
5.98 / 7.70
7.95 / 9.23
5.64 / 6.55
6.25 / 7.26
5.89 / 6.83
3.50 / 4.06
5.00 / 5.82
6.00 / 6.96
6.84 / 7.94
8.16 / 9.47
5.00 / 5.81
5.64 / 6.55
6.25 / 7.26
5.31 / 6.17
5.92 / 6.87
4.56 / 5.29
5.17 / 6.00
5.76 / 6.69
4.89 / 5.68
5.48 / 6.36
4.65 / 5.40
2.50 / 2.90
3.50 / 4.07
5.00 / 5.80
6.00 / 6.98
7.10 / 8.27
8.86 / 10.29
3.50 / 4.05
5.00 / 5.81
6.00 / 6.95
7.05 / 7.28
8.38 / 9.73
5.00 / 5.80
5.81 / 6.75
6.44 / 7.47
5.47 / 6.35
6.08 / 7.06
5.73 / 6.66
3.50 / 4.07
5.00 / 5.79
6.00 / 6.97
6.63 / 7.70
7.95 / 9.23
4.84 / 5.63
5.47 / 6.35
6.08 / 7.06
5.17 / 6.00
5.76 / 6.69
5.45 / 6.33

20 + 20 + 25 + 35 + 60
20 + 20 + 25 + 35 + 71
20 + 20 + 25 + 35 + 100
20 + 20 + 25 + 50 + 50
20 + 20 + 25 + 50 + 60
20 + 20 + 25 + 60 + 60
20 + 20 + 25 + 60 + 71
20 + 20 + 35 + 35 + 35
20 + 20 + 35 + 35 + 50
20 + 20 + 35 + 35 + 60
20 + 20 + 35 + 35 + 71
20 + 20 + 35 + 50 + 50
20 + 20 + 35 + 50 + 60
20 + 20 + 35 + 50 + 71
20 + 20 + 35 + 60 + 60
20 + 20 + 50 + 50 + 50
20 + 20 + 50 + 50 + 60
20 + 25 + 25 + 25 + 25
20 + 25 + 25 + 25 + 35
20 + 25 + 25 + 25 + 50
20 + 25 + 25 + 25 + 60
20 + 25 + 25 + 25 + 71
20 + 25 + 25 + 25 + 100
20 + 25 + 25 + 35 + 35
20 + 25 + 25 + 35 + 50
20 + 25 + 25 + 35 + 60
20 + 25 + 25 + 35 + 71
20 + 25 + 25 + 50 + 50
20 + 25 + 25 + 50 + 60
20 + 25 + 25 + 50 + 71
20 + 25 + 35 + 35 + 35
20 + 25 + 35 + 35 + 50
20 + 25 + 35 + 35 + 60
20 + 25 + 35 + 35 + 71
20 + 25 + 35 + 50 + 50
20 + 25 + 35 + 50 + 60
20 + 25 + 35 + 50 + 71
20 + 25 + 35 + 60 + 60
20 + 25 + 50 + 50 + 50
20 + 35 + 35 + 35 + 35
20 + 35 + 35 + 35 + 50
20 + 35 + 35 + 35 + 60
20 + 35 + 35 + 35 + 71
20 + 35 + 35 + 50 + 50
20 + 35 + 35 + 50 + 60
25 + 25 + 25 + 25 + 25
25 + 25 + 25 + 25 + 35
25 + 25 + 25 + 25 + 50
25 + 25 + 25 + 25 + 60
25 + 25 + 25 + 25 + 71
25 + 25 + 25 + 25 + 100
25 + 25 + 25 + 35 + 35
25 + 25 + 25 + 35 + 50
25 + 25 + 25 + 35 + 60
25 + 25 + 25 + 35 + 71
25 + 25 + 25 + 50 + 50

1.94 / 2.25
1.81 / 2.11
1.55 / 1.80
1.88 / 2.18
1.77 / 2.06
1.68 / 1.95
1.58 / 1.84
2.00 / 2.32
1.94 / 2.25
1.82 / 2.12
1.71 / 1.99
1.77 / 2.06
1.68 / 1.95
1.58 / 1.84
1.59 / 1.85
1.63 / 1.89
1.55 / 1.80
2.00 / 2.32
2.00 / 2.32
2.00 / 2.32
2.00 / 2.32
1.87 / 2.17
1.59 / 1.85
2.00 / 2.33
2.00 / 2.32
1.88 / 2.18
1.76 / 2.05
1.82 / 2.12
1.72 / 2.00
1.62 / 1.88
2.00 / 2.32
1.88 / 2.18
1.77 / 2.06
1.67 / 1.94
1.72 / 2.20
1.63 / 1.89
1.54 / 1.79
1.55 / 1.80
1.59 / 1.85
1.94 / 2.25
1.77 / 2.06
1.68 / 1.95
1.58 / 1.84
1.63 / 1.89
1.55 / 1.80
2.50 / 2.90
2.50 / 2.91
2.50 / 2.90
2.42 / 2.81
2.27 / 2.63
1.94 / 2.25
2.50 / 2.90
2.42 / 2.81
2.28 / 2.65
2.14 / 2.49
2.21 / 2.57

1.94 / 2.25
1.81 / 2.11
1.55 / 1.80
1.88 / 2.18
1.77 / 2.06
1.68 / 1.95
1.58 / 1.84
2.00 / 2.32
1.94 / 2.25
1.82 / 2.12
1.71 / 1.99
1.77 / 2.06
1.68 / 1.95
1.58 / 1.84
1.59 / 1.85
1.63 / 1.89
1.55 / 1.80
2.50 / 2.90
2.50 / 2.90
2.50 / 2.90
2.50 / 2.90
2.33 / 2.71
1.99 / 2.31
2.50 / 2.91
2.50 / 2.90
2.35 / 2.73
2.20 / 2.56
2.28 / 2.65
2.15 / 2.50
2.04 / 2.36
2.50 / 2.90
2.35 / 2.73
2.21 / 2.57
2.08 / 2.42
2.15 / 2.50
2.04 / 2.37
1.93 / 2.24
1.94 / 2.25
1.99 / 2.31
3.39 / 3.94
3.10 / 3.60
2.93 / 3.41
2.77 / 3.21
2.86 / 3.32
2.71 / 3.15
2.50 / 2.90
2.50 / 2.91
2.50 / 2.90
2.42 / 2.81
2.27 / 2.63
1.94 / 2.25
2.50 / 2.90
2.42 / 2.81
2.28 / 2.65
2.14 / 2.49
2.21 / 2.57

2.42 / 2.81
2.27 / 2.63
1.94 / 2.25
2.35 / 2.73
2.21 / 2.57
2.09 / 2.43
1.98 / 2.30
3.50 / 4.06
3.39 / 3.94
3.19 / 3.71
3.00 / 3.48
3.10 / 3.60
2.93 / 3.41
2.77 / 3.21
2.78 / 3.23
4.08 / 4.74
3.88 / 4.50
2.50 / 2.90
2.50 / 2.90
2.50 / 2.90
2.50 / 2.90
2.33 / 2.71
1.99 / 2.31
2.50 / 2.91
2.50 / 2.90
2.35 / 2.73
2.20 / 2.56
2.28 / 2.65
2.15 / 2.50
2.04 / 2.36
3.50 / 4.06
3.29 / 3.82
3.10 / 3.60
2.92 / 3.39
3.01 / 3.50
2.86 / 3.32
2.70 / 3.13
2.71 / 3.15
3.97 / 4.62
3.39 / 3.94
3.10 / 3.60
2.93 / 3.41
2.77 / 3.21
2.86 / 3.32
2.71 / 3.15
2.50 / 2.90
2.50 / 2.91
2.50 / 2.90
2.42 / 2.81
2.27 / 2.63
1.94 / 2.25
2.50 / 2.90
2.42 / 2.81
2.28 / 2.65
2.14 / 2.49
2.21 / 2.57

3.39 / 3.94
3.17 / 3.68
2.71 / 3.15
4.70 / 5.45
4.70 / 5.14
5.03 / 5.84
4.74 / 5.51
3.50 / 4.06
3.39 / 3.94
3.19 / 3.71
3.00 / 3.48
4.43 / 5.14
4.19 / 4.86
3.95 / 4.59
4.77 / 5.54
4.08 / 4.74
3.88 / 4.50
2.50 / 2.90
2.50 / 2.90
2.50 / 2.90
2.50 / 2.90
2.33 / 2.71
1.99 / 2.31
3.50 / 4.08
3.50 / 4.06
3.29 / 3.82
3.08 / 3.58
4.56 / 5.29
4.31 / 5.00
4.89 / 4.71
3.50 / 4.06
3.29 / 3.82
3.10 / 3.60
2.92 / 3.39
4.31 / 5.00
4.08 / 4.74
3.86 / 4.48
4.65 / 5.40
3.97 / 4.62
3.39 / 3.94
3.10 / 3.60
2.93 / 3.41
2.77 / 3.21
4.08 / 4.74
3.88 / 4.50
2.50 / 2.90
2.50 / 2.91
2.50 / 2.90
2.42 / 2.81
2.27 / 2.63
1.94 / 2.25
3.50 / 4.06
3.39 / 3.94
3.19 / 3.71
3.00 / 3.48
4.43 / 5.14

5.81 / 6.75
6.44 / 7.47
7.75 / 9.00
4.70 / 5.45
4.70 / 5.14
5.03 / 5.84
5.61 / 6.52
3.50 / 4.06
4.84 / 5.63
5.47 / 6.35
6.08 / 7.06
4.43 / 5.14
5.03 / 5.84
5.61 / 6.52
4.77 / 5.54
4.08 / 4.74
4.65 / 5.40
2.50 / 2.90
3.50 / 4.07
5.00 / 5.79
6.00 / 6.97
6.63 / 7.70
7.95 / 9.23
3.50 / 4.08
5.00 / 5.81
5.64 / 6.55
6.25 / 7.28
4.56 / 5.29
5.17 / 6.00
4.89 / 4.71
3.50 / 4.06
4.70 / 5.45
5.31 / 6.17
5.92 / 6.87
4.31 / 5.00
4.89 / 5.68
5.48 / 6.36
4.65 / 5.40
3.97 / 4.62
3.39 / 3.94
4.43 / 5.14
5.03 / 5.84
5.61 / 6.52
4.08 / 4.74
4.65 / 5.40
2.50 / 2.90
3.50 / 4.07
5.00 / 5.80
5.81 / 6.75
6.44 / 7.47
7.75 / 9.00
3.50 / 4.06
4.84 / 5.63
5.47 / 6.35
6.08 / 7.06
4.43 / 5.14

The Flexible & Efficient Multi-Split Range

1.4.26

Multi-Split Combinations
MXZ-8B160yA
1 OUTDOOR UNIT
Indoor Unit
Combination

Indoor Unit
Combination

UPTO 8 INDOOR UNITS

Cooling / Heating Capacity (kW)


Unit A

Cooling / Heating Capacity (kW)


Unit A

Unit B

Unit C

Unit D

Unit E

25 + 25 + 25 + 50 + 60
25 + 25 + 25 + 50 + 71
25 + 25 + 25 + 60 + 60
25 + 25 + 35 + 35 + 35
25 + 25 + 35 + 35 + 50
25 + 25 + 35 + 35 + 60
25 + 25 + 35 + 35 + 71
25 + 25 + 35 + 50 + 50
25 + 25 + 35 + 50 + 60
25 + 25 + 50 + 50 + 50
25 + 35 + 35 + 35 + 35
25 + 35 + 35 + 35 + 50
25 + 35 + 35 + 35 + 60
25 + 35 + 35 + 35 + 71
25 + 35 + 35 + 50 + 50
35 + 35 + 35 + 35 + 35
35 + 35 + 35 + 35 + 50
35 + 35 + 35 + 35 + 60

2.09 / 2.43
1.98 / 2.30
1.99 / 2.31
2.50 / 2.90
2.39 / 2.65
2.15 / 2.50
2.03 / 2.36
2.09 / 2.43
1.99 / 2.31
1.94 / 2.25
2.35 / 2.73
2.15 / 2.50
2.04 / 2.37
1.93 / 2.24
1.99 / 2.31
3.10 / 3.60
2.86 / 3.32
2.71 / 3.15

2.09 / 2.43
1.98 / 2.30
1.99 / 2.31
2.50 / 2.90
2.39 / 2.65
2.15 / 2.50
2.03 / 2.36
2.09 / 2.43
1.99 / 2.31
1.94 / 2.25
3.29 / 3.82
3.01 / 3.50
2.86 / 3.32
2.70 / 3.13
2.78 / 3.23
3.10 / 3.60
2.86 / 3.32
2.71 / 3.15

2.09 / 2.43
1.98 / 2.30
1.99 / 2.31
3.50 / 4.06
3.35 / 3.71
3.01 / 3.50
2.84 / 3.30
2.93 / 3.41
2.78 / 3.23
3.88 / 4.50
3.29 / 3.82
3.01 / 3.50
2.86 / 3.32
2.70 / 3.13
2.78 / 3.23
3.10 / 3.60
2.86 / 3.32
2.71 / 3.15

4.19 / 4.86
3.95 / 4.59
4.77 / 5.54
3.50 / 4.06
3.35 / 3.71
3.01 / 3.50
2.84 / 3.30
4.19 / 4.86
3.97 / 4.62
3.88 / 4.50
3.29 / 3.82
3.01 / 3.50
2.86 / 3.32
2.70 / 3.13
3.97 / 4.62
3.10 / 3.60
2.86 / 3.32
2.71 / 3.15

5.03 / 5.84
5.61 / 6.52
4.77 / 5.54
3.50 / 4.06
4.02 / 5.29
5.17 / 6.00
5.76 / 6.69
4.19 / 4.86
4.77 / 5.54
3.88 / 4.50
3.29 / 3.82
4.31 / 5.00
4.89 / 5.68
5.48 / 6.36
3.97 / 4.62
3.10 / 3.60
4.08 / 4.74
4.65 / 5.40

6 ROOMS
20 + 20 + 20 + 20 + 20 + 20
20 + 20 + 20 + 20 + 20 + 25
20 + 20 + 20 + 20 + 20 + 35
20 + 20 + 20 + 20 + 20 + 50
20 + 20 + 20 + 20 + 20 + 60
20 + 20 + 20 + 20 + 20 + 71
20 + 20 + 20 + 20 + 20 + 100
20 + 20 + 20 + 20 + 25 + 25
20 + 20 + 20 + 20 + 25 + 35
20 + 20 + 20 + 20 + 25 + 50
20 + 20 + 20 + 20 + 25 + 60
20 + 20 + 20 + 20 + 25 + 71
20 + 20 + 20 + 20 + 35 + 35
20 + 20 + 20 + 20 + 35 + 50
20 + 20 + 20 + 20 + 35 + 60
20 + 20 + 20 + 20 + 35 + 71
20 + 20 + 20 + 20 + 50 + 50
20 + 20 + 20 + 20 + 50 + 60
20 + 20 + 20 + 20 + 50 + 71
20 + 20 + 20 + 20 + 60 + 60
20 + 20 + 20 + 25 + 25 + 25
20 + 20 + 20 + 25 + 25 + 35
20 + 20 + 20 + 25 + 25 + 50
20 + 20 + 20 + 25 + 25 + 60
20 + 20 + 20 + 25 + 25 + 71

2.00 / 2.32
2.00 / 2.32
2.00 / 2.33
2.00 / 2.32
1.94 / 2.25
1.81 / 2.11
1.55 / 1.80
2.00 / 2.32
2.00 / 2.33
2.00 / 2.32
1.88 / 2.18
1.76 / 2.05
2.00 / 2.32
1.88 / 2.18
1.77 / 2.06
1.67 / 1.94
1.72 / 2.00
1.63 / 1.89
1.54 / 1.79
1.55 / 1.80
2.00 / 2.33
2.00 / 2.32
1.94 / 2.25
1.82 / 2.12
1.71 / 1.99

2.00 / 2.32
2.00 / 2.32
2.00 / 2.33
2.00 / 2.32
1.94 / 2.25
1.81 / 2.11
1.55 / 1.80
2.00 / 2.32
2.00 / 2.33
2.00 / 2.32
1.88 / 2.18
1.76 / 2.05
2.00 / 2.32
1.88 / 2.18
1.77 / 2.06
1.67 / 1.94
1.72 / 2.00
1.63 / 1.89
1.54 / 1.79
1.55 / 1.80
2.00 / 2.33
2.00 / 2.32
1.94 / 2.25
1.82 / 2.12
1.71 / 1.99

2.00 / 2.32
2.00 / 2.32
2.00 / 2.33
2.00 / 2.32
1.94 / 2.25
1.81 / 2.11
1.55 / 1.80
2.00 / 2.32
2.00 / 2.33
2.00 / 2.32
1.88 / 2.18
1.76 / 2.05
2.00 / 2.32
1.88 / 2.18
1.77 / 2.06
1.67 / 1.94
1.72 / 2.00
1.63 / 1.89
1.54 / 1.79
1.55 / 1.80
2.00 / 2.33
2.00 / 2.32
1.94 / 2.25
1.82 / 2.12
1.71 / 1.99

2.00 / 2.32
2.00 / 2.32
2.00 / 2.33
2.00 / 2.32
1.94 / 2.25
1.81 / 2.11
1.55 / 1.80
2.00 / 2.32
2.00 / 2.33
2.00 / 2.32
1.88 / 2.18
1.76 / 2.05
2.00 / 2.32
1.88 / 2.18
1.77 / 2.06
1.67 / 1.94
1.72 / 2.00
1.63 / 1.89
1.54 / 1.79
1.55 / 1.80
2.50 / 2.91
2.50 / 2.90
2.42 / 2.81
2.28 / 2.65
2.14 / 2.49

2.00 / 2.32
2.00 / 2.32
2.00 / 2.33
2.00 / 2.32
1.94 / 2.25
1.81 / 2.11
1.55 / 1.80
2.50 / 2.90
2.00 / 2.33
2.50 / 2.90
2.35 / 2.73
2.20 / 2.56
3.50 / 4.06
3.29 / 3.82
3.10 / 3.60
2.92 / 3.39
4.31 / 5.00
4.08 / 4.74
3.86 / 4.48
4.65 / 5.40
2.50 / 2.91
2.50 / 2.90
2.42 / 2.81
2.28 / 2.65
2.14 / 2.49

Unit F

2.00 / 2.32
2.50 / 2.90
3.50 / 4.07
5.00 / 5.80
5.81 / 6.75
6.44 / 7.47
7.75 / 9.00
2.50 / 2.90
3.50 / 4.08
5.00 / 5.81
5.64 / 6.55
6.25 / 7.26
3.50 / 4.06
4.70 / 5.45
5.31 / 6.17
5.92 / 6.87
4.31 / 5.00
4.89 / 5.68
5.48 / 6.36
4.65 / 5.40
2.50 / 2.91
3.50 / 4.06
4.84 / 5.63
5.47 / 6.35
6.08 / 7.06

Unit G

Unit H

Unit B

Unit C

Unit D

Unit E

Unit F

25 + 35 + 35 + 35 + 35 + 35

1.94 / 2.25 2.71 / 3.15 2.71 / 3.15 2.71 / 3.15 2.71 / 3.15 2.71 / 3.15

7 ROOMS
20 + 20 + 20 + 20 + 20 + 20 + 20
20 + 20 + 20 + 20 + 20 + 20 + 25
20 + 20 + 20 + 20 + 20 + 20 + 35
20 + 20 + 20 + 20 + 20 + 20 + 50
20 + 20 + 20 + 20 + 20 + 20 + 60
20 + 20 + 20 + 20 + 20 + 20 + 71
20 + 20 + 20 + 20 + 20 + 25 + 25
20 + 20 + 20 + 20 + 20 + 25 + 35
20 + 20 + 20 + 20 + 20 + 25 + 50
20 + 20 + 20 + 20 + 20 + 25 + 60
20 + 20 + 20 + 20 + 20 + 25 + 71
20 + 20 + 20 + 20 + 20 + 35 + 35
20 + 20 + 20 + 20 + 20 + 35 + 50
20 + 20 + 20 + 20 + 20 + 35 + 60
20 + 20 + 20 + 20 + 20 + 50 + 50
20 + 20 + 20 + 20 + 25 + 25 + 25
20 + 20 + 20 + 20 + 25 + 25 + 35
20 + 20 + 20 + 20 + 25 + 25 + 50
20 + 20 + 20 + 20 + 25 + 25 + 60
20 + 20 + 20 + 20 + 25 + 25 + 71
20 + 20 + 20 + 20 + 25 + 35 + 35
20 + 20 + 20 + 20 + 25 + 35 + 50
20 + 20 + 20 + 20 + 25 + 35 + 60
20 + 20 + 20 + 20 + 35 + 35 + 35
20 + 20 + 20 + 20 + 35 + 35 + 50
20 + 20 + 20 + 25 + 25 + 25 + 25
20 + 20 + 20 + 25 + 25 + 25 + 35
20 + 20 + 20 + 25 + 25 + 25 + 50
20 + 20 + 20 + 25 + 25 + 25 + 60
20 + 20 + 20 + 25 + 25 + 35 + 35
20 + 20 + 20 + 25 + 25 + 35 + 50
20 + 20 + 20 + 25 + 35 + 35 + 35
20 + 20 + 20 + 35 + 35 + 35 + 35
20 + 20 + 25 + 25 + 25 + 25 + 25
20 + 20 + 25 + 25 + 25 + 25 + 35
20 + 20 + 25 + 25 + 25 + 25 + 50
20 + 20 + 25 + 25 + 25 + 25 + 60
20 + 20 + 25 + 25 + 25 + 35 + 35
20 + 20 + 25 + 25 + 25 + 35 + 50
20 + 20 + 25 + 25 + 35 + 35 + 35
20 + 25 + 25 + 25 + 25 + 25 + 25
20 + 25 + 25 + 25 + 25 + 25 + 35
20 + 25 + 25 + 25 + 25 + 25 + 50
20 + 25 + 25 + 25 + 25 + 35 + 35

2.00 / 2.33
1.93 / 2.32
1.81 / 2.32
1.82 / 2.12
1.72 / 2.00
1.62 / 1.88
2.00 / 2.32
1.94 / 2.25
1.77 / 2.06
1.68 / 1.95
1.58 / 1.84
1.82 / 2.12
1.68 / 1.95
1.59 / 1.85
1.55 / 1.80
2.00 / 2.32
1.88 / 2.18
1.72 / 2.00
1.63 / 1.89
1.54 / 1.79
1.77 / 2.06
1.63 / 1.89
1.55 / 1.80
1.68 / 1.95
1.55 / 1.80
1.94 / 2.25
1.82 / 2.12
1.68 / 1.95
1.59 / 1.85
1.72 / 2.00
1.59 / 1.85
1.63 / 1.89
1.55 / 1.80
1.88 / 2.18
1.77 / 2.06
1.63 / 1.89
1.55 / 1.80
1.68 / 1.95
1.55 / 1.80
1.59 / 1.85
1.82 / 2.12
1.72 / 2.00
1.59 / 1.85
1.63 / 1.89

2.00 / 2.33
1.93 / 2.32
1.81 / 2.32
1.82 / 2.12
1.72 / 2.00
1.62 / 1.88
2.00 / 2.32
1.94 / 2.25
1.77 / 2.06
1.68 / 1.95
1.58 / 1.84
1.82 / 2.12
1.68 / 1.95
1.59 / 1.85
1.55 / 1.80
2.00 / 2.32
1.88 / 2.18
1.72 / 2.00
1.63 / 1.89
1.54 / 1.79
1.77 / 2.06
1.63 / 1.89
1.55 / 1.80
1.68 / 1.95
1.55 / 1.80
1.94 / 2.25
1.82 / 2.12
1.68 / 1.95
1.59 / 1.85
1.72 / 2.00
1.59 / 1.85
1.63 / 1.89
1.55 / 1.80
1.88 / 2.18
1.77 / 2.06
1.63 / 1.89
1.55 / 1.80
1.68 / 1.95
1.55 / 1.80
1.59 / 1.85
2.28 / 2.65
2.15 / 2.50
1.99 / 2.31
2.04 / 2.37

2.00 / 2.33
1.93 / 2.32
1.81 / 2.32
1.82 / 2.12
1.72 / 2.00
1.62 / 1.88
2.00 / 2.32
1.94 / 2.25
1.77 / 2.06
1.68 / 1.95
1.58 / 1.84
1.82 / 2.12
1.68 / 1.95
1.59 / 1.85
1.55 / 1.80
2.00 / 2.32
1.88 / 2.18
1.72 / 2.00
1.63 / 1.89
1.54 / 1.79
1.77 / 2.06
1.63 / 1.89
1.55 / 1.80
1.68 / 1.95
1.55 / 1.80
1.94 / 2.25
1.82 / 2.12
1.68 / 1.95
1.59 / 1.85
1.72 / 2.00
1.59 / 1.85
1.63 / 1.89
1.55 / 1.80
2.35 / 2.73
2.21 / 2.57
2.04 / 2.37
1.94 / 2.25
2.09 / 2.43
1.94 / 2.25
1.99 / 2.31
2.28 / 2.65
2.15 / 2.50
1.99 / 2.31
2.04 / 2.37

2.00 / 2.33
1.93 / 2.32
1.81 / 2.32
1.82 / 2.12
1.72 / 2.00
1.62 / 1.88
2.00 / 2.32
1.94 / 2.25
1.77 / 2.06
1.68 / 1.95
1.58 / 1.84
1.82 / 2.12
1.68 / 1.95
1.59 / 1.85
1.55 / 1.80
2.00 / 2.32
1.88 / 2.18
1.72 / 2.00
1.63 / 1.89
1.54 / 1.79
1.77 / 2.06
1.63 / 1.89
1.55 / 1.80
1.68 / 1.95
1.55 / 1.80
2.42 / 2.81
2.28 / 2.65
2.09 / 2.43
1.99 / 2.31
2.15 / 2.50
1.99 / 2.31
2.04 / 2.37
2.71 / 3.15
2.35 / 2.73
2.21 / 2.57
2.04 / 2.37
1.94 / 2.25
2.09 / 2.43
1.94 / 2.25
1.99 / 2.31
2.28 / 2.65
2.15 / 2.50
1.99 / 2.31
2.04 / 2.37

2.00 / 2.33
1.93 / 2.32
1.81 / 2.32
1.82 / 2.12
1.72 / 2.00
1.62 / 1.88
2.00 / 2.32
1.94 / 2.25
1.77 / 2.06
1.68 / 1.95
1.58 / 1.84
1.82 / 2.12
1.68 / 1.95
1.59 / 1.85
1.55 / 1.80
2.50 / 2.90
2.35 / 2.73
2.15 / 2.50
2.04 / 2.37
1.93 / 2.24
2.21 / 2.57
2.04 / 2.37
1.94 / 2.25
2.93 / 3.41
2.71 / 3.15
2.42 / 2.81
2.28 / 2.65
2.09 / 2.43
1.99 / 2.31
2.15 / 2.50
1.99 / 2.31
2.86 / 3.32
2.71 / 3.15
2.35 / 2.73
2.21 / 2.57
2.04 / 2.37
1.94 / 2.25
2.09 / 2.43
1.94 / 2.25
2.78 / 3.23
2.28 / 2.65
2.15 / 2.50
1.99 / 2.31
2.04 / 2.37

2.00 / 2.33
1.93 / 2.32
1.81 / 2.32
1.82 / 2.12
1.72 / 2.00
1.62 / 1.88
2.50 / 2.90
2.42 / 2.81
2.21 / 2.57
2.09 / 2.43
1.98 / 2.30
3.19 / 3.71
2.93 / 3.41
2.78 / 3.23
3.88 / 4.50
2.50 / 2.90
2.35 / 2.73
2.15 / 2.50
2.04 / 2.37
1.93 / 2.24
3.10 / 3.60
2.86 / 3.32
2.71 / 3.15
2.93 / 3.41
2.71 / 3.15
2.42 / 2.81
2.28 / 2.65
2.09 / 2.43
1.99 / 2.31
3.01 / 3.50
2.78 / 3.23
2.86 / 3.32
2.71 / 3.15
2.35 / 2.73
2.21 / 2.57
2.04 / 2.37
1.94 / 2.25
2.93 / 3.41
2.71 / 3.15
2.78 / 3.23
2.28 / 2.65
2.15 / 2.50
1.99 / 2.31
2.86 / 3.15

Unit G

2.00 / 2.33
2.41 / 2.56
3.14 / 4.06
4.00 / 5.29
5.17 / 6.00
5.76 / 6.69
2.50 / 2.90
3.39 / 3.94
4.43 / 5.14
5.03 / 5.84
5.61 / 6.52
3.19 / 3.71
4.19 / 4.86
4.77 / 5.54
3.88 / 4.50
2.50 / 2.90
3.29 / 3.82
4.31 / 5.00
4.89 / 5.68
5.48 / 6.36
3.10 / 3.60
4.08 / 4.74
4.65 / 5.40
2.93 / 3.41
3.88 / 4.50
2.42 / 2.81
3.19 / 3.71
4.19 / 4.86
4.77 / 5.54
3.01 / 3.50
3.97 / 4.62
2.86 / 3.32
2.71 / 3.15
2.35 / 2.73
3.10 / 3.60
4.08 / 4.74
4.65 / 5.40
2.93 / 3.41
3.88 / 4.50
2.78 / 3.23
2.28 / 2.65
3.01 / 3.50
3.97 / 4.62
2.86 / 3.15

Unit H

20 + 20 + 20 + 25 + 35 + 35
20 + 20 + 20 + 25 + 35 + 50
20 + 20 + 20 + 25 + 35 + 60
20 + 20 + 20 + 25 + 35 + 71
20 + 20 + 20 + 25 + 50 + 50
20 + 20 + 20 + 25 + 50 + 60
20 + 20 + 20 + 35 + 35 + 35
20 + 20 + 20 + 35 + 35 + 50
20 + 20 + 20 + 35 + 35 + 60
20 + 20 + 20 + 35 + 35 + 71
20 + 20 + 20 + 35 + 50 + 50
20 + 20 + 25 + 25 + 25 + 25
20 + 20 + 25 + 25 + 25 + 35
20 + 20 + 25 + 25 + 25 + 50
20 + 20 + 25 + 25 + 25 + 60
20 + 20 + 25 + 25 + 25 + 71
20 + 20 + 25 + 25 + 35 + 35
20 + 20 + 25 + 25 + 35 + 50
20 + 20 + 25 + 25 + 35 + 60
20 + 20 + 25 + 25 + 35 + 71
20 + 20 + 25 + 25 + 50 + 50
20 + 20 + 25 + 25 + 50 + 60
20 + 20 + 25 + 35 + 35 + 35
20 + 20 + 25 + 35 + 35 + 50
20 + 20 + 25 + 35 + 35 + 60
20 + 20 + 25 + 35 + 50 + 50
20 + 20 + 35 + 35 + 35 + 35
20 + 20 + 35 + 35 + 35 + 50
20 + 25 + 25 + 25 + 25 + 25
20 + 25 + 25 + 25 + 25 + 35
20 + 25 + 25 + 25 + 25 + 50
20 + 25 + 25 + 25 + 25 + 60
20 + 25 + 25 + 25 + 25 + 71
20 + 25 + 25 + 25 + 35 + 35
20 + 25 + 25 + 25 + 35 + 50
20 + 25 + 25 + 25 + 35 + 60
20 + 25 + 25 + 25 + 35 + 71
20 + 25 + 25 + 25 + 50 + 50
20 + 25 + 25 + 35 + 35 + 35
20 + 25 + 25 + 35 + 35 + 50
20 + 25 + 25 + 35 + 35 + 60
20 + 25 + 35 + 35 + 35 + 35
20 + 25 + 35 + 35 + 35 + 50
20 + 35 + 35 + 35 + 35 + 35
25 + 25 + 25 + 25 + 25 + 25
25 + 25 + 25 + 25 + 25 + 35
25 + 25 + 25 + 25 + 25 + 50
25 + 25 + 25 + 25 + 25 + 60
25 + 25 + 25 + 25 + 25 + 71
25 + 25 + 25 + 25 + 35 + 35
25 + 25 + 25 + 25 + 35 + 50
25 + 25 + 25 + 25 + 35 + 60
25 + 25 + 25 + 25 + 50 + 50
25 + 25 + 25 + 35 + 35 + 35
25 + 25 + 25 + 35 + 35 + 50
25 + 25 + 35 + 35 + 35 + 35

2.00 / 2.32
1.82 / 2.12
1.72 / 2.00
1.62 / 1.88
1.68 / 1.95
1.59 / 1.85
1.88 / 2.18
1.72 / 2.00
1.63 / 1.89
1.54 / 1.79
1.59 / 1.85
2.00 / 2.33
2.00 / 2.32
1.88 / 2.18
1.77 / 2.06
1.67 / 1.94
1.94 / 2.25
1.77 / 2.06
1.68 / 1.95
1.58 / 1.84
1.63 / 1.89
1.55 / 1.80
1.82 / 2.12
1.68 / 1.95
1.59 / 1.85
1.55 / 1.80
1.72 / 2.00
1.59 / 1.85
2.00 / 2.32
2.00 / 2.32
1.82 / 2.12
1.72 / 2.00
1.62 / 1.88
1.88 / 2.18
1.72 / 2.00
1.63 / 1.89
1.54 / 1.79
1.59 / 1.85
1.77 / 2.06
1.63 / 1.89
1.55 / 1.80
1.68 / 1.95
1.55 / 1.80
1.59 / 1.85
2.50 / 2.81
2.42 / 2.81
2.21 / 2.57
2.09 / 2.43
1.98 / 2.30
2.28 / 2.65
2.09 / 2.43
1.99 / 2.31
1.94 / 2.25
1.94 / 2.50
1.99 / 2.31
2.04 / 2.37

Air Conditioning
1.4.27 1.121

2.00 / 2.32
1.82 / 2.12
1.72 / 2.00
1.62 / 1.88
1.68 / 1.95
1.59 / 1.85
1.88 / 2.18
1.72 / 2.00
1.63 / 1.89
1.54 / 1.79
1.59 / 1.85
2.00 / 2.33
2.00 / 2.32
1.88 / 2.18
1.77 / 2.06
1.67 / 1.94
1.94 / 2.25
1.77 / 2.06
1.68 / 1.95
1.58 / 1.84
1.63 / 1.89
1.55 / 1.80
1.82 / 2.12
1.68 / 1.95
1.59 / 1.85
1.55 / 1.80
1.72 / 2.00
1.59 / 1.85
2.50 / 2.90
2.50 / 2.90
2.28 / 2.65
2.15 / 2.50
2.03 / 2.36
2.35 / 2.73
2.15 / 2.50
2.04 / 2.37
1.93 / 2.24
1.99 / 2.31
2.21 / 2.57
2.04 / 2.37
1.94 / 2.25
2.09 /2.43
1.94 / 2.25
2.78 / 3.23
2.50 / 2.81
2.42 / 2.81
2.21 / 2.57
2.09 / 2.43
1.98 / 2.30
2.28 / 2.65
2.09 / 2.43
1.99 / 2.31
1.94 / 2.25
1.94 / 2.50
1.99 / 2.31
2.04 / 2.37

2.00 / 2.32
1.82 / 2.12
1.72 / 2.00
1.62 / 1.88
1.68 / 1.95
1.59 / 1.85
1.88 / 2.18
1.72 / 2.00
1.63 / 1.89
1.54 / 1.79
1.59 / 1.85
2.50 / 2.91
2.50 / 2.90
2.35 / 2.73
2.21 / 2.57
2.08 / 2.42
2.42 / 2.81
2.21 / 2.57
2.09 / 2.43
1.98 / 2.30
2.04 / 2.37
1.94 / 2.25
2.28 / 2.65
2.09 / 2.43
1.99 / 2.31
1.94 / 2.25
3.01 / 3.50
2.78 / 3.23
2.50 / 2.90
2.50 / 2.90
2.28 / 2.65
2.15 / 2.50
2.03 / 2.36
2.35 / 2.73
2.15 / 2.50
2.04 / 2.37
1.93 / 2.24
1.99 / 2.31
2.21 / 2.57
2.04 / 2.37
1.94 / 2.25
2.93 / 3.41
2.71 / 3.15
2.78 / 3.23
2.50 / 2.81
2.42 / 2.81
2.21 / 2.57
2.09 / 2.43
1.98 / 2.30
2.28 / 2.65
2.09 / 2.43
1.99 / 2.31
1.94 / 2.25
1.94 / 2.50
1.99 / 2.31
2.86 / 3.32

2.50 / 2.90
2.28 / 2.65
2.15 / 2.50
2.03 / 2.36
2.09 / 2.43
1.99 / 2.31
3.29 / 3.82
3.01 / 3.50
2.86 / 3.32
2.70 / 3.13
2.78 / 3.23
2.50 / 2.91
2.50 / 2.90
2.35 / 2.73
2.21 / 2.57
2.08 / 2.42
2.42 / 2.81
2.21 / 2.57
2.09 / 2.43
1.98 / 2.30
2.04 / 2.37
1.94 / 2.25
3.19 / 3.71
2.93 / 3.41
2.78 / 3.23
2.71 / 3.15
3.01 / 3.50
2.78 / 3.23
2.50 / 2.90
2.50 / 2.90
2.28 / 2.65
2.15 / 2.50
2.03 / 2.36
2.35 / 2.73
2.15 / 2.50
2.04 / 2.37
1.93 / 2.24
1.99 / 2.31
3.10 / 3.60
2.86 / 3.32
2.71 / 3.15
2.93 / 3.41
2.71 / 3.15
2.78 / 3.23
2.50 / 2.81
2.42 / 2.81
2.21 / 2.57
2.09 / 2.43
1.98 / 2.30
2.28 / 2.65
2.09 / 2.43
1.99 / 2.31
1.94 / 2.25
2.72 / 3.50
2.78 / 3.23
2.86 / 3.32

3.50 / 4.06
3.19 / 3.71
3.01 / 3.50
2.84 / 3.30
4.19 / 4.86
3.97 / 4.62
3.29 / 3.82
3.01 / 3.50
2.86 / 3.32
2.70 / 3.13
3.97 / 4.62
2.50 / 2.91
2.50 / 2.90
2.35 / 2.73
2.21 / 2.57
2.08 / 2.42
3.39 / 3.94
3.10 / 3.60
2.93 / 3.31
2.77 / 3.21
4.08 / 4.74
3.88 / 4.50
3.19 / 3.71
2.93 / 3.41
2.78 / 3.23
3.88 / 4.50
3.01 / 3.50
2.78 / 3.23
2.50 / 2.90
2.50 / 2.90
2.28 / 2.65
2.15 / 2.50
2.03 / 2.36
3.29 / 3.82
3.01 / 3.50
2.86 / 3.32
2.70 / 3.13
3.97 / 4.62
3.10 / 3.60
2.86 / 3.32
2.71 / 3.15
2.93 / 3.41
2.71 / 3.15
2.78 / 3.23
2.50 / 2.81
2.42 / 2.81
2.21 / 2.57
2.09 / 2.43
1.98 / 2.30
3.19 / 3.71
2.93 / 3.41
2.78 / 3.23
3.88 / 4.50
2.72 / 3.50
2.78 / 3.23
2.86 / 3.32

3.50 / 4.06
4.56 / 5.29
5.17 / 6.00
5.76 / 6.69
4.19 / 4.86
4.77 / 5.54
3.29 / 3.82
4.31 / 5.00
4.89 / 5.68
5.48 / 6.36
3.97 / 4.62
2.50 / 2.91
3.50 / 4.06
4.70 / 5.45
5.31 / 6.17
5.92 / 6.87
3.39 / 3.94
4.43 / 5.17
5.03 / 5.84
5.61 / 6.52
4.08 / 4.74
4.65 / 5.40
3.19 / 3.71
4.19 / 4.86
4.77 / 5.54
3.88 / 4.50
3.01 / 3.50
3.97 / 4.62
2.50 / 2.90
3.50 / 4.06
4.56 / 5.29
5.17 / 6.00
5.76 / 6.69
3.29 / 3.82
4.31 / 5.00
4.89 / 5.68
5.48 / 6.36
3.97 / 4.62
3.10 / 3.60
4.08 / 4.74
4.65 / 5.40
2.93 / 3.41
3.88 / 4.50
2.78 / 3.23
2.50 / 2.81
3.39 / 3.94
4.43 / 5.14
5.03 / 5.84
5.61 / 6.52
3.19 / 3.71
4.19 / 4.86
4.77 / 5.54
3.88 / 4.50
2.72 / 3.50
3.97 / 4.62
2.86 / 3.32

20 + 25 + 25 + 25 + 35 + 35 + 35
25 + 25 + 25 + 25 + 25 + 25 + 25
25 + 25 + 25 + 25 + 25 + 25 + 35
25 + 25 + 25 + 25 + 25 + 25 + 50
25 + 25 + 25 + 25 + 25 + 35 + 35

1.55 / 1.80
2.21 / 2.57
2.09 / 2.43
1.94 / 2.25
1.99 / 2.31

1.94 / 2.25
2.21 / 2.57
2.09 / 2.43
1.94 / 2.25
1.99 / 2.31

1.94 / 2.25
2.21 / 2.57
2.09 / 2.43
1.94 / 2.25
1.99 / 2.31

1.94 / 2.25
2.21 / 2.57
2.09 / 2.43
1.94 / 2.25
1.99 / 2.31

2.71 / 3.15
2.21 / 2.57
2.09 / 2.43
1.94 / 2.25
1.99 / 2.31

2.71 / 3.15
2.21 / 2.57
2.09 / 2.43
1.94 / 2.25
2.78 / 3.23

2.71 / 3.15
2.21 / 2.57
2.93 / 3.41
3.88 / 4.50
2.78 / 3.23

8 ROOMS
20 + 20 + 20 + 20 + 20 + 20 + 20 + 20
20 + 20 + 20 + 20 + 20 + 20 + 20 + 25
20 + 20 + 20 + 20 + 20 + 20 + 20 + 35
20 + 20 + 20 + 20 + 20 + 20 + 20 + 50
20 + 20 + 20 + 20 + 20 + 20 + 20 + 60
20 + 20 + 20 + 20 + 20 + 20 + 25 + 25
20 + 20 + 20 + 20 + 20 + 20 + 25 + 35
20 + 20 + 20 + 20 + 20 + 20 + 25 + 50
20 + 20 + 20 + 20 + 20 + 20 + 35 + 35
20 + 20 + 20 + 20 + 20 + 25 + 25 + 25
20 + 20 + 20 + 20 + 20 + 25 + 25 + 35
20 + 20 + 20 + 20 + 20 + 25 + 25 + 50
20 + 20 + 20 + 20 + 20 + 25 + 35 + 35
20 + 20 + 20 + 20 + 25 + 25 + 25 + 25
20 + 20 + 20 + 20 + 25 + 25 + 25 + 35
20 + 20 + 20 + 20 + 25 + 25 + 35 + 35
20 + 20 + 20 + 25 + 25 + 25 + 25 + 25
20 + 20 + 20 + 25 + 25 + 25 + 25 + 35
20 + 20 + 25 + 25 + 25 + 25 + 25 + 25
20 + 20 + 25 + 25 + 25 + 25 + 25 + 35
20 + 25 + 25 + 25 + 25 + 25 + 25 + 25
25 + 25 + 25 + 25 + 25 + 25 + 25 + 25

1.94 / 2.25
1.88 / 2.18
1.77 / 2.06
1.63 / 1.89
1.55 / 1.80
1.82 / 2.12
1.72 / 2.00
1.59 / 1.85
1.63 / 1.89
1.77 / 2.06
1.68 / 1.95
1.55 / 1.80
1.59 / 1.85
1.72 / 2.00
1.63 / 1.89
1.55 / 1.80
1.68 / 1.95
1.59 / 1.85
1.63 / 1.89
1.55 / 1.80
1.59 / 1.85
1.94 / 2.25

1.94 / 2.25
1.88 / 2.18
1.77 / 2.06
1.63 / 1.89
1.55 / 1.80
1.82 / 2.12
1.72 / 2.00
1.59 / 1.85
1.63 / 1.89
1.77 / 2.06
1.68 / 1.95
1.55 / 1.80
1.59 / 1.85
1.72 / 2.00
1.63 / 1.89
1.55 / 1.80
1.68 / 1.95
1.59 / 1.85
1.63 / 1.89
1.55 / 1.80
1.99 / 2.31
1.94 / 2.25

1.94 / 2.25
1.88 / 2.18
1.77 / 2.06
1.63 / 1.89
1.55 / 1.80
1.82 / 2.12
1.72 / 2.00
1.59 / 1.85
1.63 / 1.89
1.77 / 2.06
1.68 / 1.95
1.55 / 1.80
1.59 / 1.85
1.72 / 2.00
1.63 / 1.89
1.55 / 1.80
1.68 / 1.95
1.59 / 1.85
2.04 / 2.37
1.94 / 2.25
1.99 / 2.31
1.94 / 2.25

1.94 / 2.25
1.88 / 2.18
1.77 / 2.06
1.63 / 1.89
1.55 / 1.80
1.82 / 2.12
1.72 / 2.00
1.59 / 1.85
1.63 / 1.89
1.77 / 2.06
1.68 / 1.95
1.55 / 1.80
1.59 / 1.85
1.72 / 2.00
1.63 / 1.89
1.55 / 1.80
2.09 / 2.43
1.99 / 2.31
2.04 / 2.37
1.94 / 2.25
1.99 / 2.31
1.94 / 2.25

1.94 / 2.25
1.88 / 2.18
1.77 / 2.06
1.63 / 1.89
1.55 / 1.80
1.82 / 2.12
1.72 / 2.00
1.59 / 1.85
1.63 / 1.89
1.77 / 2.06
1.68 / 1.95
1.55 / 1.80
1.59 / 1.85
2.15 / 2.50
2.04 / 2.37
1.94 / 2.25
2.09 / 2.43
1.99 / 2.31
2.04 / 2.37
1.94 / 2.25
1.99 / 2.31
1.94 / 2.25

1.94 / 2.25
1.88 / 2.18
1.77 / 2.06
1.63 / 1.89
1.55 / 1.80
1.82 / 2.12
1.72 / 2.00
1.59 / 1.85
1.63 / 1.89
2.21 / 2.57
2.09 / 2.43
1.94 / 2.25
1.99 / 2.31
2.15 / 2.50
2.04 / 2.37
1.94 / 2.25
2.09 / 2.43
1.99 / 2.31
2.04 / 2.37
1.94 / 2.25
1.99 / 2.31
1.94 / 2.25

1.94 / 2.25
1.88 / 2.18
1.77 / 2.06
1.63 / 1.89
1.55 / 1.80
2.28 / 2.65
2.15 / 2.50
1.99 / 2.31
2.86 / 3.32
2.21 / 2.57
2.09 / 2.43
1.94 / 2.25
2.78 / 3.23
2.15 / 2.50
2.04 / 2.37
2.71 / 3.15
2.09 / 2.43
1.99 / 2.31
2.04 / 2.37
1.94 / 2.25
1.99 / 2.31
1.94 / 2.25

1.94 / 2.25
2.35 / 2.73
3.10 / 3.60
4.08 / 4.74
4.65 / 5.40
2.28 / 2.65
3.01 / 3.50
3.97 / 4.62
2.86 / 3.32
2.21 / 2.57
2.93 / 3.41
3.88 / 4.50
2.78 / 3.23
2.15 / 2.50
2.86 / 3.32
2.71 / 3.15
2.09 / 2.43
2.78 / 3.23
2.04 / 2.37
2.71 / 3.15
1.99 / 2.31
1.94 / 2.25

The Flexible & Efficient Multi-Split Range

City Multi
Energy Efficient VRF Systems

The Energy Efficient

City Multi
VRF Range

The City Multi range is Mitsubishi Electrics answer to large scale VRF (Variable Refrigerant
Flow) applications.The technology of City Multi is second to none and offers excellent
seasonal energy efficiency, low running costs and reduced CO2 emissions.
Suitable for medium to large buildings that demand high performance with optimum efficiency,
our City Multi VRF range can run numerous indoor units connected to one outdoor unit.

VRF Systems
Our City Multi VRF Systems offer both heat pump and heat recovery technology. Heat pump systems deliver cooling or heating to a
space, whereas heat recovery systems can simultaneously provide cooling and heating at the same time via separate indoor units, moving
energy around a building for maximum efficiency.
The City Multi Y Series heat pump system offers a simple and flexible solution where there is a demand for a changeover capability between
heating and cooling for all indoor units, helping to ensure a constant and comfortable indoor climate. The City Multi R2 heat recovery system
can provide simultaneous heating and cooling through only two pipes rather than the conventional three which are traditionally used on
heat recovery systems, typically reducing installation time and material costs. Recovered energy can not only be moved around rooms
within a building but can also be upgraded to heat water for sanitary use.
By transferring wasted heat in this way, substantial savings can be made on annual running costs and CO2 emissions. With a range of
over 80 indoor units of varying capacity including floor standing, ducted, ceiling cassettes, ceiling suspended and wall mounted types,
up to 50 indoor units can be connected to one City Multi outdoor unit.

1.5.3

1.121
Air Conditioning

The Energy Efficient City Multi VRF Range

1.5.4

The Energy Efficient

City Multi

Air Cooled

Wide range of heat pump options


2 pipe heat recovery through branch controller
Available in standard low footprint, or high efficiency variants
Specific models designed to replace any R22 VRF systems and utilise existing piping, wiring and power
Zubadan systems available for best heating performance at low ambient

Water
Cooled

Available in heat pump and heat recovery


Applicable to standard water systems or ground source systems
Small, quiet condensors situated indoors
Offers double heat recovery through refrigerant and water circuit

VRF Range

HVRF

Set to rival traditional cooling


and heating, the new HVRF
system delivers optimum comfort
and efficiency, using an innovative
combination of unique 2-pipe
technology and water to provide
simultaneous heating and cooling
with heat recovery

Note: For further information on this system please contact your local sales office

HVRF heat recovery outdoor unit

Hybrid Branch Controller (HBC)

Heat /cool flow and return headers

Water based fan coils

Heat exchangers

DC inverter
water pumps
8 ports

2 and 3 way
control valves

2 refrigerant pipes

Water piping providing heating or cooling simultaneously

Continual research and development has led to the latest generation YKM High
COP (-EP) air sourced VRF models in both heat pump and heat recovery.
These models have been optimised for seasonal performance, providing up to 15% improvement in efficiency over outgoing
YJM high COP models. This performance can be further enhanced using the new automatic refrigerant temperature control
function, for even further efficiency and comfort. Product design improvements have enhanced the seasonal efficiency,
however this may effect nominal COP/EER.

New Feature
New PUMY small VRF outdoor units with improved efficiency and pipe runs
Increase in room temperature and setpoint accuracy by using 0.5C resolution
(PAR-31MAA remote controller required). Available on the entire City Multi range

The Energy Efficient

City Multi
VRF Range

The Importance of Seasonal Efficiency


Widely accepted by the industry, COPs and EERs give a good indication of a systems performance, but
in reality they do not give the full story of how a product will operate at different seasonal temperatures.
Seasonal Efficiency, or SCOP and SEER take into account the efficiency at varying temperatures and partial loads throughout the year
highlighting the huge benefit VRF technology brings to all City Multi products.

The Ecodesign Directive for Energy Related Products (ErP)


With buildings accounting for around half of all UK greenhouse emissions, legislation is demanding increased energy efficiency.
The Ecodesign Directive (ErP) is focusing on this area in a bid to reduce overall energy consumption, and to accelerate market
transformation to more energy efficient products.
An air conditioner will vary performance over changing seasons which means calculating seasonal performance is important to ascertain
the true performance of an air conditioning system. Ecodesign Directive reflects this by setting minimum efficiency requirements and a new
method of measuring performance introduced across the EU and hence new energy ratings are achievable.*

Enhanced Capital Allowance


Mitsubishi Electric has developed a range of highly efficient systems which successfully qualify for ECA
and are registered in the Energy Technology List.

For further information please go to etl.decc.gov.uk/etl


Nominal Conditions: Cooling; indoor 27C DB, 19C WB; outdoor 35C DB, 24C WB.
Nominal Conditions: Heating; indoor 20C DB; outdoor 7C DB, 6C WB.
UK Conditions: Summer; indoor 21C DB, 15C WB; outdoor 27C DB.
UK Conditions: Winter; indoor 21C DB; outdoor 0C DB, -1C WB.
SEER is calculated according to the Non-Domestic Building Services Compliance Guide.
SCOP for air source models is calculated according to the following data:
Profile based on COP priority mode. 0.05 x 100% capacity at -10CWB outdoor;
0.10 x 75% capacity at -5CWB outdoor; 0.55 x 50% capacity at 5CWB outdoor;
0.30 x 25% capacity at 12CWB outdoor Indoor: 20CDB. Pipe Length: 7.5m.
Calculation includes defrost correction.
SCOP for water source models is calculated according to the following data:
Profile (25% loading for each condition).
100% capacity at 10C inlet water; 75% capacity at 14C inlet water
50% capacity at 18C inlet water; 25% capacity at 22C inlet water
Indoor: 20CDB. Pipe Length: 7.5m. Nominal water flow rate.
* City Multi VRF will become part of this legislation over the next few years

1.5.5

1.121
Air Conditioning

The Energy Efficient City Multi VRF Range

1.5.6

The Energy Efficient

City Multi
VRF Range

Advanced Information Modelling


Understanding accurately how cooling, heating, ventilation and controls equipment
interacts within a building requires collaboration throughout its entire lifespan. Mitsubishi
Electric have developed two avenues to extend this collaboration, through integration
within EDSL Tas building simulation software and providing Building Information
Modelling (BIM) Revit files.

EDSL Tas Collaboration


Accurate and dynamic modelling of performance of cooling, heating and ventilation equipment within buildings goes a
step further in understanding true efficiency and effectiveness. Environmental Design Solutions Ltd (EDSL) has partnered
with Mitsubishi Electric UK to enable full integration of City Multi, Mr Slim, Heating and Lossnay products within the Tas
Thermal Analysis Software.
The software enables systems to be simply added to a project and the buildings performance to be modelled with the
actual equipment to be installed. The software can not only size equipment but can demonstrate energy consumption
and efficiency and create Part L compliance reports and Energy Performance Certificates (EPCs).

BIM Revit Files


The built environment is one of the nations largest polluters and
BIM (Building Information Modelling) can provide an integrated
approach to the construction market to ensure that assets are
delivered and maintained in the cleanest, leanest way possible.
Mitsubishi Electric provides BIM Revit files for City Multi,
Lossnay, Heating and Controls Products.

Both EDSL Tas and the BIM Revit files will be continually
updated with the latest products, always allowing users
to choose and model the most efficient and effective products.

The Energy Efficient

City Multi
VRF Range

A Wide Choice of Models


The air sourced outdoor models are modular in design and as such differing combinations
of them can be connected together to create the required outdoor unit size needed for a
particular application. The models also make use of an extra large single module.
Both the Y Heat Pump and R2 Heat Recovery Series come in Standard (-P) and High COP (-EP) versions. In addition,
the standard versions allow for space-saving by virtue of the combination of units having a smaller footprint than the
High COP versions.

The model line up


Size
Series

Model Name

PUHY-P

PUHY-EP

PURY-P

PURY-EP

R2

1.5.7

1.121
Air Conditioning

200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000 1050 1100 1150 1200 1250
8hp 10hp 12hp 14hp 16hp 18hp 20hp 22hp 24hp 26hp 28hp 30hp 32hp 34hp 36hp 38hp 40hp 42hp 44hp 46hp 48hp 50hp

The Energy Efficient City Multi VRF Range

1.5.8

The Energy Efficient

City Multi
VRF Range

The model line up


Y Series Heat Pump - Standard Version
Y Series (8-12hp) PUHY-P YJM-A

Y Series (28-30hp) PUHY-P YSJM-A

Y Series (42hp) PUHY-P YSJM-A

8hp
10hp
12hp

28hp
30hp

42hp

PUHY-P200 YJM-A
PUHY-P250 YJM-A
PUHY-P300 YJM-A

PUHY-P700 YSJM-A
PUHY-P750 YSJM-A

PUHY-P1050 YSJM-A

Y Series (14-16hp) PUHY-P YJM-A


14hp
16hp

PUHY-P350 YJM-A
PUHY-P400 YJM-A

Y Series (32-34hp) PUHY-P YSJM-A

Y Series (44hp) PUHY-P YSJM-A

32hp
34hp

44hp

PUHY-P800 YSJM-A
PUHY-P850 YSJM-A

PUHY-P1100 YSJM-A

Y Series (18hp) PUHY-P YJM-A


18hp

PUHY-P450 YJM-A

Y Series (20-22hp) PUHY-P YSJM-A


20hp
22hp

Y Series (36hp) PUHY-P YSJM-A

Y Series (46-48hp) PUHY-P YSJM-A

36hp

46hp
48hp

PUHY-P900 YSJM-A

PUHY-P1150 YSJM-A
PUHY-P1200 YSJM-A

PUHY-P500 YSJM-A
PUHY-P550 YSJM-A

Y Series (24-26hp) PUHY-P YSJM-A

Y Series (38-40hp) PUHY-P YSJM-A

Y Series (50hp) PUHY-P YSJM-A

24hp
26hp

38hp
40hp

50hp

PUHY-P600 YSJM-A
PUHY-P650 YSJM-A

PUHY-P950 YSJM-A
PUHY-P1000 YSJM-A

PUHY-P1250 YSJM-A

Y Series Heat Pump - High COP Version


Y Series (8hp) PUHY-EP YKM-A

Y Series (20hp) PUHY-EP YSKM-A

Y Series (30hp) PUHY-EP YSKM-A

8hp

20hp

30hp

PUHY-EP200 YKM-A

PUHY-EP500 YSKM-A

PUHY-EP750 YSKM-A

Y Series (10hp) PUHY-EP YKM-A

Y Series (22hp) PUHY-EP YSKM-A

Y Series (32hp) PUHY-EP YSKM-A

10hp

22hp

32hp

PUHY-EP250 YKM-A

PUHY-EP550 YSKM-A

PUHY-EP800 YSKM-A

Y Series (12hp) PUHY-EP YKM-A

Y Series (24hp) PUHY-EP YSKM-A

Y Series (34hp) PUHY-EP YSKM-A

12hp

24hp

34hp

PUHY-EP300 YKM-A

PUHY-EP600 YSKM-A

Y Series (16hp) PUHY-EP YSKM-A

Y Series (26hp) PUHY-EP YSKM-A

16hp

26hp

PUHY-EP400 YSKM-A

PUHY-EP650 YSKM-A

Y Series (18hp) PUHY-EP YSKM-A

Y Series (28hp) PUHY-EP YSKM-A

18hp

28hp

PUHY-EP450 YSKM-A

PUHY-EP700 YSKM-A

PUHY-EP850 YSKM-A

Y Series (36hp) PUHY-EP YSKM-A


36hp

PUHY-EP900 YSKM-A

The Energy Efficient

City Multi
VRF Range

R2 Series Heat Recovery - Standard Version


R2 Series (8-12hp) PURY-P YJM-A

R2 Series (18-24hp) PURY-P YSJM-A(1)

8hp
10hp
12hp

18hp
20hp
22hp
24hp

PURY-P200 YJM-A
PURY-P250 YJM-A
PURY-P300 YJM-A

PURY-P450 YSJM-A1
PURY-P500 YSJM-A
PURY-P550 YSJM-A
PURY-P600 YSJM-A

R2 Series (34hp) PURY-P YSJM-A


34hp

PURY-P850 YSJM-A

R2 Series (14-16hp) PURY-P YJM-A

R2 Series (26-28hp) PURY-P YSJM-A

R2 Series (36hp) PURY-P YSJM-A

14hp
16hp

26hp
28hp

36hp

PURY-P350 YJM-A
PURY-P400 YJM-A

PURY-P650 YSJM-A
PURY-P700 YSJM-A

R2 Series (18hp) PURY-P YJM-A

R2 Series (30-32hp) PURY-P YSJM-A

18hp

30hp
32hp

PURY-P450 YJM-A

PURY-P900 YSJM-A

PURY-P750 YSJM-A
PURY-P800 YSJM-A

R2 Series Heat Recovery - High COP Version


R2 Series (8-10hp) PURY-EP YKM-A

R2 Series (22hp) PURY-EP YSKM-A

8hp

PURY-EP200 YKM-A

22hp

10hp

PURY-EP250 YKM-A

PURY-EP550 YSKM-A

R2 Series (12-14hp) PURY-EP YKM-A

R2 Series (24-28hp) PURY-EP YSKM-A

12hp

PURY-EP300 YKM-A

14hp

PURY-EP350 YKM-A

24hp
26hp
28hp

PURY-EP600 YSKM-A
PURY-EP650 YSKM-A
PURY-EP700 YSKM-A

R2 Series (16-20hp) PURY-EP YSKM-A

1.5.9

1.121
Air Conditioning

16hp

PURY-EP400 YSKM-A

18hp
20hp

PURY-EP450 YSKM-A
PURY-EP500 YSKM-A

The Energy Efficient City Multi VRF Range

1.5.10

The Energy Efficient

City Multi

Product Range Overview


Outdoor Units
12.5kW Cooling Capacity

140kW Cooling Capacity

Y Series

WY / WR2 Series

Y Series
Zubadan

Y Series
Replace Multi

R2 Series
Replace Multi

Y / R2 Series

Y / R2 Series

Y / R2 Series

Y Series

Y / R2 Series

Y / R2 Series

PUMY-P112-140V/YKM

PQ(H/R)Y-P200-300YHM-A

PUHY-HP200/250YHM-A

PUHY-RP200-350YJM-B

PURY-RP200-300YJM-B

PU(H/R)Y-P200-300YJM-A

PU(H/R)Y-P350/400YJM-A

PU(H/R)Y-P450YJM-A

PUHY-EP200YKM-A

PUHY-EP250YKM-A
PURY-EP200/250YKM-A

PUHY-EP300YKM-A
PURY-EP300/350YKM-A

VRF Range

Indoor Units

15

(1.7kW)

20

(2.2kW)

25

(2.8kW)

32

(3.6kW)

40

(4.5kW)

50

(5.6kW)

63

(7.1kW)

80

(9.0kW)

100

(11.2kW)

PLFY-P-VBM-E
PLFY-P-VCM-E
PMFY-P-VBM-E
PEFY-P-VMS1-E
PEFY-P-VMA-E
PEFY-P-VMH(S)-E
PCFY-P-VKM-E
PKFY-P-VBM/ VHM/VKM-E
PFFY-P-VLRM-E
PFFY-P-VLRMM-E
PFFY-P-VLEM-E
PFFY-P-VKM-E
GUF-RD4
PWFY-P-VM-E-BU
*1 Nominal heating capacity 12.5kW.

*1

125

(14.0kW)

140

(16.0kW)

200

(22.4kW)

250

(28.0kW)

The Energy Efficient

City Multi
VRF Range

Contents

Y Series (4.5-6hp)

1.5.12

Y Series Standard (8-18hp)

WR2 Series (8-24hp)

1.5.56

1.5.14

PFD-P-VM-E

1.5.58

Y Series Standard (20-30hp)

1.5.16

PLFY-P-VBM-E

1.5.60

Y Series Standard (32-36hp)

1.5.18

PLFY-P-VCM-E

1.5.62

Y Series Standard (38-44hp)

1.5.20

PMFY-P-VBM-E

1.5.64

Y Series Standard (46-50hp)

1.5.22

PEFY-P-VMS1-E

1.5.66

Y Series High COP (8-18hp)

1.5.24

PEFY-P-VMA-E

1.5.68

Y Series High COP (20-24hp)

1.5.26

PEFY-P-VMH(S)-E

1.5.70

Y Series High COP (26-30hp)

1.5.28

PCFY-P-VKM-E

1.5.72

Y Series High COP (32-36hp)

1.5.30

PKFY-P-VBM-E/VHM-E/VKM-E

1.5.74

Y Series Zubadan (8-20hp)

1.5.32

PFFY-P-VLRM-E

1.5.76

Y Series Replace Multi (8-26hp)

1.5.34

PFFY-P-VLRMM-E

1.5.78

R2 Series Standard (8-18hp)

1.5.38

PFFY-P-VLEM-E

1.5.80

R2 Series Standard (18-28hp)

1.5.40

PFFY-P-VKM-E

1.5.82

R2 Series Standard (30-36hp)

1.5.42

PAC-LV11M

1.5.84

R2 Series High COP (8-20hp)

1.5.44

GUF-RD4

1.5.86

1.5.46

PWFY-P100VM-E-BU

1.5.88

R2 Series Replace Multi (8-12hp)

1.5.48

VRF HP DXE

1.5.90

R2 Series

1.5.50

BC Controllers

1.5.92

WY Series (8-24hp)

1.5.51

PAC-AH-M-J

1.5.96

WY Series (26-36hp)

1.5.52

Heat Pump, Outdoor Unit


Heat Pump, Outdoor Unit
Heat Pump, Outdoor Unit
Heat Pump, Outdoor Unit
Heat Pump, Outdoor Unit
Heat Pump, Outdoor Unit
Heat Pump, Outdoor Unit
Heat Pump, Outdoor Unit
Heat Pump, Outdoor Unit
Heat Pump, Outdoor Unit
Heat Pump, Outdoor Unit
Heat Pump, Outdoor Unit

Heat Recovery, Outdoor Unit


Heat Recovery, Outdoor Unit
Heat Recovery, Outdoor Unit
Heat Recovery, Outdoor Unit

R2 Series High COP (22-28hp)


Heat Recovery, Outdoor Unit

Heat Recovery, Outdoor Unit


Piping Restrictions

Heat Pump, Water Cooled Condensing Unit


Heat Pump, Water Cooled Condensing Unit

Air Conditioning
1.5.11 1.121

Heat Recovery, Water Cooled Condensing Unit


Heat Pump, Close Control System
4-Way Blow Ceiling Cassette Indoor Unit
600x600 4-Way Blow Ceiling Cassette Indoor Unit
1-Way Blow Ceiling Cassette Indoor Unit
Ultra Thin Ceiling Concealed Ducted Indoor Unit
Ceiling Concealed Ducted Indoor Unit
High Static Pressure Ceiling Concealed Ducted Indoor Unit

Ceiling Suspended Indoor Unit


Wall Mounted Indoor Unit

Floor Standing Concealed Indoor Unit


Floor Standing Concealed Indoor Unit
Floor Standing Exposed Indoor Unit
Floor Standing Exposed Indoor Unit
LEV Kit Interface
Lossnay Outdoor Air Processing Unit
VRF Heat Pump Boiler
Heat Pump Air Curtain

Air Handling Unit Controllers

Refrigerant Detection Systems

1.5.98

Accessories / Optional Extras

1.5.100

The Energy Efficient City Multi VRF Range

1.5.12

Y Series (4.5-6hp)
Heat Pump Outdoor Unit

The new PUMY City Multi models allow up to 12 indoor units to be connected to a single outdoor unit, using the standard
branch pipework system proven in the larger models. Utilising the latest Mitsubishi Electric inverter technology, the system
is fully controllable with all City Multi controllers or linked to third party BEMS.

Key Features
Improved seasonal efficiency through new HIC circuit, increased heat exchanger surface area and improved fan shape
Latest in inverter technology including a highly efficient DC Scroll Compressor, DC fan motor and Demand Control
Improved pipe lengths and height difference
New AC pre-heating control reduces standby power input
A two core non-polar transmission line allows for simple installation of up to 12 indoor units
the condensing unit is extremely slimline which allows easy location and application of the system
Anti-Corrosion blue and flat fin technology
Expanded operation range down to -20C in heating
Connect stylish M Series wall mounted indoor units to the system via the LEV kit interface (PAC-LV11)

MODEL REFERENCE
CAPACITY (kW)

POWER INPUT (kW)

Heating (nominal)
Cooling (nominal)
Heating (UK)
Cooling (UK)
Heating (nominal)
Cooling (nominal)
Heating (UK)
Cooling (UK)

COP / EER (nominal)


SCOP / SEER*
Max no. OF CONNECTABLE INDOOR UNITS
Max CONNECTABLE CAPACITY
AIRFLOW (m3/min)
PIPE SIZE mm (in)
Gas
Liquid
SOUND PRESSURE LEVEL (dBA)
WEIgHT (kg)
DIMENSIONS (mm)
Width
Depth
Height
ELECTRICAL SUPPLY
PHASE
STARTINg CURRENT (A)
RUNNINg CURRENT (A) Heating
Cooling
gUARANTEED OPERATINg RANgE Cooling
Heating
FUSE RATINg (BS88) - HRC (A)
MAINS CABLE No. Cores

PUMY-P112VKM

PUMY-P112YKM

PUMY-P125VKM

PUMY-P125YKM

PUMY-P140VKM

PUMY-P140YKM

14.0
12.5
11.6
11.5
3.04
2.79
2.71
1.87
4.61 / 4.48
-/9
50-130% OU Capacity
110
15.88 (5/8)
9.52 (3/8)
49
123
1050
330+30
1338
220-240v, 50Hz
Single
5
13.42
12.32
-5C ~ 46C
-20C ~ 15C
1 x 32
3

14.0
12.5
11.6
11.5
3.04
2.79
2.71
1.87
4.61 / 4.48
-/9
50-130% OU Capacity
110
15.88 (5/8)
9.52 (3/8)
49
125
1050
330+30
1338
380-415v, 50Hz
Three
5
4.62
4.24
-5C ~ 46C
-20C ~ 15C
1 x 16
4 + earth

16.0
14.0
13.3
12.9
3.74
3.46
3.33
2.32
4.28 / 4.05
-/10
50-130% OU Capacity
110
15.88 (5/8)
9.52 (3/8)
50
123
1050
330+30
1338
220-240v, 50Hz
Single
5
16.51
15.27
-5C ~ 46C
-20C ~ 15C
1 x 32
3

16.0
14.0
13.3
12.9
3.74
3.46
3.33
2.32
4.28 / 4.05
-/10
50-130% OU Capacity
110
15.88 (5/8)
9.52 (3/8)
50
125
1050
330+30
1338
380-415v, 50Hz
Three
5
5.68
5.26
-5C ~ 46C
-20C ~ 15C
1 x 16
4 + earth

18.0
15.5
14.9
14.3
4.47
4.52
3.98
3.03
4.03 / 3.43
-/12
50-130% OU Capacity
110
15.88 (5/8)
9.52 (3/8)
51
123
1050
330+30
1338
220-240v, 50Hz
Single
5
19.73
19.95
-5C ~ 46C
-20C ~ 15C
1 x 32
3

18.0
15.5
14.9
14.3
4.47
4.52
3.98
3.03
4.03 / 3.43
-/12
50-130% OU Capacity
110
15.88 (5/8)
9.52 (3/8)
51
125
1050
330+30
1338
380-415v, 50Hz
Three
5
6.79
6.87
-5C ~ 46C
-20C ~ 15C
1 x 16
4 + earth

PIPING REStRICtIONS

PUMY-P112-140VKM/YKM Piping Restrictions

TOTAL PIPINg LENgTH


FURTHEST PIPINg LENgTH
FURTHEST PIPINg LENgTH AFTER 1st BRANCH
BETWEEN INDOOR AND OUTDOOR UNITS - HEIgHT
BETWEEN INDOOR AND INDOOR UNITS - HEIgHT

300m max
150m max
30m max
50m max (40m max if outdoor installed below)
15m max

Note: *SEER/SCOP data provided seperately

Product Dimensions

PUMY-P112/125/140V(Y)KA

Upper View

Rear Air Intake


225

600

2-U Shaped notched holes


(Foundation Bolt M10)

225

19

Installation Feet

42

Air Discharge

Side View

28

25

56
33
0
53
70

Rear View

417

370

330

Side Air Intake

56
2-1236 Oval holes
(Foundation Bolt M10)

Front View

Side View
1050

362

510

26

369

426

1062

632

1338

Service panel

Air Conditioning
1.5.13 1.121

Y Series (4.5-6hp) - Heat Pump Outdoor Unit

1.5.14

Y Series Standard
(8-18hp)

Setting the standard in efficiency


The City Multi Y Series makes use of a two pipe refrigerant circuit throughout, with branch pipes feeding indoor units,
allowing manual changeover from cooling to heating to ensure that a constant indoor climate is maintained.

Key Features

Heat Pump Outdoor Unit

Wrap around coil for improved energy efficiency


Branch pipes feeding indoor units
Energy-saving inverter driven outdoor compressor units with very low start currents
No requirement for plant rooms or bulky service shafts
Pipe run of 165m, with a total system pipe length of 1000m
100% inverter control
High Sensible Cooling Function - by raising the off coil temperature, a 10% increase in sensible cooling capacity
over standard operation is achievable, the result being greater comfort for occupants
High Performance Heating Mode for low ambient conditions
Compact chassis for easier installation

MODEL REFERENCE
CAPACITY (kW)

POWER INPUT (kW)

Heating (nominal)
Cooling (nominal)
High Performance Heating (UK)
COP Priority Heating (UK)
Cooling (UK)
Heating (nominal)
Cooling (nominal)
High Performance Heating (UK)
COP Priority Heating (UK)
Cooling (UK)

COP / EER (nominal)


SCOP / SEER
MAx No. OF CONNECTABLE INDOOR UNITS
AIRFLOW (m3/min)
High
SOUND PRESSURE LEVEL (dBA)
SOUND POWER LEVEL (dBA)
WEIgHT (kg)
DIMENSIONS (mm)
Width
Depth
(1650mm without legs)
Height
ELECTRICAL SUPPLY*
PHASE*
STARTINg CURRENT (A)*
NOMINAL SYSTEM
Heating
RUNNINg CURRENT (A)* Cooling
FUSE RATINg (MCB sizes BS EN 60947-2) - (A)*
MAINS CABLE No. Cores*

PUHY-P200YJM-A

PUHY-P250YJM-A

PUHY-P300YJM-A

PUHY-P350YJM-A

PUHY-P400YJM-A

PUHY-P450YJM-A

25.0
22.4
25.0
22.8
21.3
5.84
5.62
7.36
5.78
3.23
4.28 / 3.98
5.18 / 7.02
17
170
56
76
190
920
760
1710
380-415v, 50Hz
Three
8
9.0
8.6
1 x 20
4 + earth

31.5
28.0
31.5
28.7
26.6
7.34
7.40
9.25
7.27
4.26
4.29 / 3.78
5.12 / 6.85
21
170
58
78
200
920
760
1710
380-415v, 50Hz
Three
8
11.3
11.4
1 x 20
4 + earth

37.5
33.5
35.6
32.3
31.5
9.25
9.00
12.40
8.97
5.81
4.05 / 3.72
4.93 / 6.23
26
170
59
79
215
920
760
1710
380-415v, 50Hz
Three
8
14.2
13.9
1 x 25
4 + earth

45.0
40.0
42.8
38.7
37.6
11.19
11.01
14.99
10.85
7.10
4.02 / 3.63
4.88 / 6.33
30
210
60
80
250
1220
760
1710
380-415v, 50Hz
Three
8
17.2
17.0
1 x 32
4 + earth

50.0
45.0
47.5
43.0
42.3
12.82
13.11
17.18
12.44
8.46
3.90 / 3.43
5.01 / 6.14
34
210
61
81
250
1220
760
1710
380-415v, 50Hz
Three
8
19.8
20.2
1 x 32
4 + earth

56.0
50.0
50.7
48.7
46.0
14.62
15.47
16.67
13.30
9.75
3.83 / 3.23
4.96 / 5.82
39
370
62
82
290
1750
760
1710
380-415v, 50Hz
Three
8
22.5
23.9
1 x 40
4 + earth

Note: * A separate power supply is required for each module. Where more than one figure is quoted there are multiple modules. Price includes Twinning Kit where necessary.

PIPING REStRICtIONS
TOTAL PIPINg LENgTH
FURTHEST PIPINg LENgTH
FURTHEST PIPINg LENgTH AFTER 1st BRANCH
BETWEEN INDOOR AND OUTDOOR UNITS - HEIgHT
BETWEEN INDOOR AND INDOOR UNITS - HEIgHT

PUHY-P200-450YJM-A
1000m max
165m max
40m max
50m max (40m max if outdoor installed below)
15m max

Product Dimensions

PUHY-P200/250/300YJM-A

Control box

Service
panel

1650
1710

Refrigerant service
valve <liquid>

1410

Intake
air

Intake
air

Intake
air

760

Upper View

240

Front View

80 150 150 150 150

Discharge air

Side View

18

884
920

18

25

760

60
55

98
102

204
251

(60)

25

(60)

60
55

90

54

132 88

72

Refrigerant service
valve <gas>

Detachable leg
(front and back,2 points)

Product Dimensions

PUHY-P350/400YJM-A
Upper View

Control box

1710

Service
panel

1650

Refrigerant service
valve <liquid>

1410

Intake
air

Intake
air

Intake
air

760

Front View

240

Side View

80 150 150 150 150

Discharge air

18

1184
1220

18

e air

25

60
55

254
301

98
102

(60)

760

(60)

25

90

132 88

54

60
55

Product Dimensions

72

Refrigerant service
valve <gas>

Detachable leg
(front and back,2 points)

PUHY-P450YJM-A

Intake
air

Refrigerant service
valve <gas>

rvice

rge air

760

150
300

19

80

50

1710

Service
panel

1650

vice
1410

Refrigerant service
valve <liquid>

150

Control box

Intake
air

Intake
air

Upper View

240

Front View
Con

80 150 150 150 150

Discharge air

Side View

831

831

19

1750

60
55

543
590

98
102

(60)

25
760

90

132 88

25

(60)

54

60
55

Air Conditioning
1.5.15 1.121

72

Contactor
box

Detachable leg
(front and back,3 points)

Y Series Standard (8-18hp) - Heat Pump Outdoor Unit

1.5.16

Y Series Standard
(20-30hp)

Setting the standard in efficiency


The City Multi Y Series makes use of a two pipe refrigerant circuit throughout, with branch pipes feeding indoor units,
allowing manual changeover from cooling to heating to ensure that a constant indoor climate is maintained.

Key Features

Heat Pump Outdoor Unit

Wrap around coil for improved energy efficiency


Branch pipes feeding indoor units
Energy-saving inverter driven outdoor compressor units with very low start currents
No requirement for plant rooms or bulky service shafts
Pipe run of 165m, with a total system pipe length of 1000m
100% inverter control
High Sensible Cooling Function - by raising the off coil temperature, a 10% increase in sensible cooling capacity
over standard operation is achievable, the result being greater comfort for occupants
High Performance Heating Mode for low ambient conditions
Compact chassis for easier installation

MODEL REFERENCE
CAPACITY (kW)

POWER INPUT (kW)

Heating (nominal)
Cooling (nominal)
High Performance Heating (UK)
COP Priority Heating (UK)
Cooling (UK)
Heating (nominal)
Cooling (nominal)
High Performance Heating (UK)
COP Priority Heating (UK)
Cooling (UK)

COP / EER (nominal)


SCOP / SEER
MAx No. OF CONNECTABLE INDOOR UNITS
High
AIRFLOW (m3/min)
SOUND PRESSURE LEVEL (dBA)
SOUND POWER LEVEL (dBA)
WEIgHT (kg)
DIMENSIONS (mm)
Width
Depth
(1650mm without legs)
Height
ELECTRICAL SUPPLY*
PHASE*
STARTINg CURRENT (A)*
NOMINAL SYSTEM
Heating
RUNNINg CURRENT (A)* Cooling
FUSE RATINg (MCB sizes BS EN 60947-2) - (A)*
MAINS CABLE No. Cores*

PUHY-P500YSJM-A

PUHY-P550YSJM-A

PUHY-P600YSJM-A

PUHY-P650YSJM-A

PUHY-P700YSJM-A

PUHY-P750YSJM-A

63.0
56.0
57.0
54.8
51.5
15.03
15.38
17.13
13.68
9.69
4.19 / 3.64
5.12 / 6.53
43
170 / 170
61
81
200 + 200
920 + 920
760
1710
380-415v, 50Hz
Three
8/8
23.2
23.7
1 x 20 / 1 x 20
4 + earth

69.0
63.0
62.4
60.0
58.0
16.87
17.16
19.23
15.35
10.81
4.09 / 3.67
4.99 / 6.39
47
170 / 170
61.5
81.5
215 + 200
920 + 920
760
1710
380-415v, 50Hz
Three
8/8
26.0
26.5
1 x 25 / 1 x 20
4 + earth

76.5
69.0
69.2
66.6
63.5
18.88
18.75
21.52
17.18
11.81
4.05 / 3.68
4.94 / 6.58
50
210 / 170
62
82
250 + 200
1220 + 920
760
1710
380-415v, 50Hz
Three
8/8
29.1
28.9
1 x 32 / 1 x 20
4 + earth

81.5
73.0
73.8
70.9
67.2
20.47
20.39
23.34
18.63
12.85
3.98 / 3.58
4.93 / 6.30
50
210 / 170
62.5
82.5
250 + 215
1220 + 920
760
1710
380-415v, 50Hz
Three
8/8
31.6
31.5
1 x 32 / 1 x 25
4 + earth

88.0
80.0
88.0
76.6
73.6
22.27
22.47
28.06
20.71
14.49
3.95 / 3.56
5.06 / 6.20
50
210 / 210
63
83
250 + 250
1220 + 1220
760
1710
380-415v, 50Hz
Three
8/8
34.4
34.7
1 x 32 / 1 x 32
4 + earth

95.0
85.0
95.0
82.7
78.2
24.67
24.70
31.08
22.94
15.93
3.85 / 3.44
5.09 / 6.06
50
210 / 210
63.5
83.5
250 + 250
1220 + 1220
760
1710
380-415v, 50Hz
Three
8/8
38.1
38.1
1 x 32 / 1 x 32
4 + earth

Note: * A separate power supply is required for each module. Where more than one figure is quoted there are multiple modules.

PIPING REStRICtIONS
TOTAL PIPINg LENgTH
FURTHEST PIPINg LENgTH
FURTHEST PIPINg LENgTH AFTER 1st BRANCH
BETWEEN INDOOR AND OUTDOOR UNITS - HEIgHT
BETWEEN INDOOR AND INDOOR UNITS - HEIgHT

PUHY-P500-750YSJM-A
1000m max
165m max
40m max
50m max (40m max if outdoor installed below)
15m max

Product Dimensions

PUHY-P500/550YSJM-A

Side View

Front View

Side View
30

920

Outdoor unit 2

Intake
air

760

1220

Discharge air

Outdoor unit 1

Intake
air

To indoor unit
Liquid Twinning pipe<optional parts>

Detachable leg

Intake
air

(60)

(60)

Intake
air

To indoor unit
Gas Twinning pipe<optional parts>

Product Dimensions

Front View

1710

1650

920

Outdoor unit 1

1710

760

Discharge air

Intake
air

PUHY-P600/650YSJM-A

30

920

Outdoor unit 2

1650

Product Dimensions

Detachable leg

Intake
air

To indoor unit
Liquid Twinning pipe<optional parts>
To indoor unit
Gas Twinning pipe<optional parts>

PUHY-P700/750YSJM-A

Side View

Front View
1220

Outdoor unit 1

30

1220

Outdoor unit 2

1710
1650

760

Discharge air

Intake
air

(60)

Intake
air

Detachable leg

Intake
air

To indoor unit
Liquid Twinning pipe <optional parts>
To indoor unit
Gas Twinning pipe <optional parts>

Air Conditioning
1.5.17 1.121

Y Series Standard (20-30hp) - Heat Pump Outdoor Unit

1.5.18

Y Series Standard
(32-36hp)
Heat Pump Outdoor Unit

Setting the standard in efficiency


The City Multi Y Series makes use of a two pipe refrigerant circuit throughout, with branch pipes feeding indoor units,
allowing manual changeover from cooling to heating to ensure that a constant indoor climate is maintained.

Key Features
Wrap around coil for improved energy efficiency
Branch pipes feeding indoor units
Energy-saving inverter driven outdoor compressor units with very low start currents
No requirement for plant rooms or bulky service shafts
Pipe run of 165m, with a total system pipe length of 1000m
100% inverter control
High Sensible Cooling Function - by raising the off coil temperature, a 10% increase in sensible cooling capacity
over standard operation is achievable, the result being greater comfort for occupants
High Performance Heating Mode for low ambient conditions
Compact chassis for easier installation

MODEL REFERENCE
CAPACITY (kW)

POWER INPUT (kW)

Heating (nominal)
Cooling (nominal)
High Performance Heating (UK)
COP Priority Heating (UK)
Cooling (UK)
Heating (nominal)
Cooling (nominal)
High Performance Heating (UK)
COP Priority Heating (UK)
Cooling (UK)

COP / EER (nominal)


SCOP / SEER
MAx No. OF CONNECTABLE INDOOR UNITS
AIRFLOW (m3/min)
High
SOUND PRESSURE LEVEL (dBA)
SOUND POWER LEVEL (dBA)
WEIgHT (kg)
DIMENSIONS (mm)
Width
Depth
(1650mm without legs)
Height
ELECTRICAL SUPPLY*
PHASE*
STARTINg CURRENT (A)*
NOMINAL SYSTEM
Heating
RUNNINg CURRENT (A)* Cooling
FUSE RATINg (MCB sizes BS EN 60947-2) - (A)*
MAINS CABLE No. Cores*

PUHY-P800YSJM-A

PUHY-P850YSJM-A

PUHY-P900YSJM-A

100.0
90.0
100.0
87.0
82.8
25.70
27.10
32.38
23.90
17.48
3.89 / 3.32
5.19 / 5.82
50
370 / 210
64
84
290 + 250
1750 + 1220
760
1710
380-415v, 50Hz
Three
8/8
39.7
41.8
1 x 40 / 1 x 32
4 + earth

108.0
96.0
102.6
95.0
88.3
28.42
29.62
37.80
26.15
18.07
3.80 / 3.24
4.82 / 6.07
50
370 / 210
64.5
84.5
290 + 250
1750 + 1220
760
1710
380-415v, 50Hz
Three
8/8
43.9
45.7
1 x 40 / 1 x 32
4 + earth

113.0
101.0
107.4
99.4
92.9
30.05
32.06
39.97
27.65
19.56
3.76 / 3.15
4.77 / 5.84
50
370 / 370
65
85
290 + 290
1750 + 1750
760
1710
380-415v, 50Hz
Three
8/8
46.4
49.5
1 x 40 / 1 x 40
4 + earth

Note: * A separate power supply is required for each module. Where more than one figure is quoted there are multiple modules.

PIPING REStRICtIONS
TOTAL PIPINg LENgTH
FURTHEST PIPINg LENgTH
FURTHEST PIPINg LENgTH AFTER 1st BRANCH
BETWEEN INDOOR AND OUTDOOR UNITS - HEIgHT
BETWEEN INDOOR AND INDOOR UNITS - HEIgHT

PUHY-P800-900YSJM-A
1000m max
165m max
40m max
50m max (40m max if outdoor installed below)
15m max

Product Dimensions

PUHY-P800/850YSJM-A

Side View

Front View

760

1750

30

1220

Outdoor unit 2

1650

Outdoor unit 1

1710

Discharge air

Intake
air

(60)

Intake
air

Intake
air

Detachable leg

To indoor unit
Liquid Twinning pipe <optional parts>
To indoor unit
Gas Twinning pipe <optional parts>

Product Dimensions

PUHY-P900YSJM-A

Side View

Front View
1750

Outdoor unit 2

Intake
air

Intake
air

(60)

Intake
air

30

1650

1750

Outdoor unit 1

1710

760

Discharge air

Detachable leg

To indoor unit
Liquid Twinning pipe <optional parts>
To indoor unit
Gas Twinning pipe <optional parts>

Air Conditioning
1.5.19 1.121

Y Series Standard (32-36hp) - Heat Pump Outdoor Unit

1.5.20

Y Series Standard
(38-44hp)
Heat Pump Outdoor Unit

Setting the standard in efficiency


The City Multi Y Series makes use of a two pipe refrigerant circuit throughout, with branch pipes feeding indoor units,
allowing manual changeover from cooling to heating to ensure that a constant indoor climate is maintained.

Key Features
Wrap around coil for improved energy efficiency
Branch pipes feeding indoor units
Energy-saving inverter driven outdoor compressor units with very low start currents
No requirement for plant rooms or bulky service shafts
Pipe run of 165m, with a total system pipe length of 1000m
100% inverter control
High Sensible Cooling Function - by raising the off coil temperature, a 10% increase in sensible cooling capacity
over standard operation is achievable, the result being greater comfort for occupants
High Performance Heating Mode for low ambient conditions
Compact chassis for easier installation

MODEL REFERENCE
CAPACITY (kW)

POWER INPUT (kW)

Heating (nominal)
Cooling (nominal)
High Performance Heating (UK)
COP Priority Heating (UK)
Cooling (UK)
Heating (nominal)
Cooling (nominal)
High Performance Heating (UK)
COP Priority Heating (UK)
Cooling (UK)

COP / EER (nominal)


SCOP / SEER
MAx No. OF CONNECTABLE INDOOR UNITS
AIRFLOW (m3/min)
High
SOUND PRESSURE LEVEL (dBA)
SOUND POWER LEVEL (dBA)
WEIgHT (kg)
DIMENSIONS (mm)
Width
Depth
(1650mm without legs)
Height
ELECTRICAL SUPPLY*
PHASE*
STARTINg CURRENT (A)*
NOMINAL SYSTEM
Heating
RUNNINg CURRENT (A)* Cooling
FUSE RATINg (MCB sizes BS EN 60947-2) - (A)*
MAINS CABLE No. Cores*

PUHY-P950YSJM-A

PUHY-P1000YSJM-A

PUHY-P1050YSJM-A

PUHY-P1100YSJM-A

119.5
108.0
113.5
105.2
99.4
30.02
30.50
39.93
27.62
18.61
3.98 / 3.54
4.97 / 6.52
50
210 / 170 / 170
64.5
84.5
250 + 215 + 200
1220 + 920 + 920
760
1710
380-415v, 50Hz
Three
8/8/8
46.4
47.1
1 x 32 / 1 x 25 / 1 x 20
4 + earth

127.0
113.0
120.7
111.8
104.0
33.15
32.10
44.09
30.50
19.58
3.83 / 3.52
4.86 / 6.33
50
210 / 170 / 170
64.5
84.5
250 + 215 + 215
1220 + 920 + 920
760
1710
380-415v, 50Hz
Three
8/8/8
51.2
49.6
1 x 32 / 1 x 25 / 1 x 25
4 + earth

132.0
118.0
125.4
116.2
108.6
34.10
33.81
45.35
31.37
20.62
3.87 / 3.49
4.91 / 6.34
50
210 / 210 / 170
65
85
250 + 250 + 215
1220 + 1220 + 920
760
1710
380-415v, 50Hz
Three
8/8/8
52.7
52.2
1 x 32 / 1 x 32 / 1 x 25
4 + earth

140.0
124.0
133.0
123.2
114.1
36.08
35.73
47.99
33.19
21.80
3.88 / 3.47
4.92 / 6.41
50
210 / 210 / 210
65
85
250 + 250 + 250
1220 + 1220 + 1220
760
1710
380-415v, 50Hz
Three
8/8/8
55.7
55.2
1 x 32 / 1 x 32 / 1 x 32
4 + earth

Note: * A separate power supply is required for each module. Where more than one figure is quoted there are multiple modules.

PIPING REStRICtIONS
TOTAL PIPINg LENgTH
FURTHEST PIPINg LENgTH
FURTHEST PIPINg LENgTH AFTER 1st BRANCH
BETWEEN INDOOR AND OUTDOOR UNITS - HEIgHT
BETWEEN INDOOR AND INDOOR UNITS - HEIgHT

PUHY-P950-1100YSJM-A
1000m max
165m max
40m max
50m max (40m max if outdoor installed below)
15m max

Front View

Side View

30

1220

760

Intake
air

Intake
air

To indoor unit
Liquid Twinning pipe 1 <optional parts>

Liquid Twinning pipe 2 <optional parts>

Gas Twinning pipe 1 <optional parts>

To indoor unit
Gas Twinning pipe 2 <optional parts>

Detachable leg

Product Dimensions
Side View

1220

Outdoor unit 1

30

1220

30

Outdoor unit 2

Intake
air

Detachable leg

920

Outdoor unit 3

Intake
air

Liquid Twinning pipe 1 <optional parts>

To indoor unit
Liquid Twinning pipe 2 <optional parts>

Gas Twinning pipe 1 <optional parts>

To indoor unit
Gas Twinning pipe 2 <optional parts>

PUHY-P1100YSJM-A

Front View

1220

Outdoor unit 1

30

1220

30

Outdoor unit 2

Intake
air

Detachable leg

Air Conditioning
1.5.21 1.121

1220

Outdoor unit 3

Intake
air

(60)

1650

760
Discharge air

1710

Intake
air

760

Discharge air

(60)

1650

1710

920

Outdoor unit 3

Intake
air

(60)

Intake
air

30

920

Outdoor unit 2

Outdoor unit 1

Discharge air

PUHY-P1050YSJM-A

Front View

1650

Side View

Product Dimensions

PUHY-P950/1000YSJM-A

1710

Product Dimensions

To indoor unit

Liquid Twinning pipe 1 <optional parts>

Liquid Twinning pipe 2 <optional parts>

Gas Twinning pipe 1 <optional parts>

Gas Twinning pipe 2 <optional parts>

To indoor unit

Y Series Standard (38-44hp) - Heat Pump Outdoor Unit

1.5.22

Y Series Standard
(46-50hp)

Setting the standard in efficiency


The City Multi Y Series makes use of a two pipe refrigerant circuit throughout, with branch pipes feeding indoor units,
allowing manual changeover from cooling to heating to ensure that a constant indoor climate is maintained.

Key Features

Heat Pump Outdoor Unit

Wrap around coil for improved energy efficiency


Branch pipes feeding indoor units
Energy-saving inverter driven outdoor compressor units with very low start currents
No requirement for plant rooms or bulky service shafts
Pipe run of 165m, with a total system pipe length of 1000m
100% inverter control
High Sensible Cooling Function - by raising the off coil temperature, a 10% increase in sensible cooling capacity
over standard operation is achievable, the result being greater comfort for occupants
High Performance Heating Mode for low ambient conditions
Compact chassis for easier installation

MODEL REFERENCE
CAPACITY (kW)

POWER INPUT (kW)

Heating (nominal)
Cooling (nominal)
High Performance Heating (UK)
COP Priority Heating (UK)
Cooling (UK)
Heating (nominal)
Cooling (nominal)
High Performance Heating (UK)
COP Priority Heating (UK)
Cooling (UK)

COP / EER (nominal)


SCOP / SEER
MAx No. OF CONNECTABLE INDOOR UNITS
High
AIRFLOW (m3/min)
SOUND PRESSURE LEVEL (dBA)
SOUND POWER LEVEL (dBA)
WEIgHT (kg)
DIMENSIONS (mm)
Width
Depth
(1650mm without legs)
Height
ELECTRICAL SUPPLY*
PHASE*
STARTINg CURRENT (A)*
NOMINAL SYSTEM
Heating
RUNNINg CURRENT (A)* Cooling
FUSE RATINg (MCB sizes BS EN 60947-2) - (A)*
MAINS CABLE No. Cores*

PUHY-P1150YSJM-A

PUHY-P1200YSJM-A

PUHY-P1250YSJM-A

145.0
130.0
137.8
127.6
119.6
37.27
38.34
49.57
34.29
23.39
3.89 / 3.39
4.86 / 6.24
50
370 / 210 / 210
65.5
85.5
290 + 250 + 250
1750 + 1220 + 1220
760
1710
380-415v, 50Hz
Three
8/8/8
57.6
59.2
1 x 40 / 1 x 32 / 1 x 32
4 + earth

150.0
136.0
142.5
132.0
125.1
39.26
40.84
52.22
36.12
24.91
3.82 / 3.33
4.84 / 6.16
50
370 / 210 / 210
66
86
290 + 250 + 250
1750 + 1220 + 1220
760
1710
380-415v, 50Hz
Three
8/8/8
60.6
63.1
1 x 40 / 1 x 32 / 1 x 32
4 + earth

156.5
140.0
148.7
137.7
128.8
40.86
42.94
54.34
37.59
26.19
3.83 / 3.26
4.86 / 5.96
50
370 / 370 / 210
66
86
290 + 290 + 250
1750 + 1750 + 1220
760
1710
380-415v, 50Hz
Three
8/8/8
63.1
66.3
1 x 40 / 1 x 40 / 1 x 32
4 + earth

Note: * A separate power supply is required for each module. Where more than one figure is quoted there are multiple modules.

PIPING REStRICtIONS
TOTAL PIPINg LENgTH
FURTHEST PIPINg LENgTH
FURTHEST PIPINg LENgTH AFTER 1st BRANCH
BETWEEN INDOOR AND OUTDOOR UNITS - HEIgHT
BETWEEN INDOOR AND INDOOR UNITS - HEIgHT

PUHY-P1150-1250YSJM-A
1000m max
165m max
40m max
50m max (40m max if outdoor installed below)
15m max

Product Dimensions

PUHY-P1150/1200YSJM-A

Side View

Front View
30

1220

30

Outdoor unit 2

Intake
air

Intake
air

Detachable leg

Product Dimensions

Liquid Twinning pipe 1 <optional parts>

To indoor unit
Liquid Twinning pipe 2 <optional parts>

Gas Twinning pipe 1 <optional parts>

To indoor unit
Gas Twinning pipe 2 <optional parts>

PUHY-P1250YSJM-A

Side View

Front View

760
Discharge air

1750

1650

1710

Outdoor unit 1

(60)

Intake
air

1220

Outdoor unit 3

(60)

Intake
air

1650

1750

Outdoor unit 1

1710

760
Discharge air

30

30

1750

Outdoor unit 2

Intake
air

Intake
air

Detachable leg

Liquid Twinning pipe 1 <optional parts>


Gas Twinning pipe 1 <optional parts>

Air Conditioning
1.5.23 1.121

1220

Outdoor unit 3

To indoor unit
Liquid Twinning pipe 2 <optional parts>
To indoor unit
Gas Twinning pipe 2 <optional parts>

Y Series Standard (46-50hp) - Heat Pump Outdoor Unit

1.5.24

Y Series High COP


(8-18hp)

New and Improved for even higher efficiency


The City Multi Y Series makes use of a two pipe refrigerant circuit throughout, with branch pipes feeding indoor units,
allowing manual changeover from cooling to heating to ensure that a constant indoor climate is maintained.

Key Features

Heat Pump Outdoor Unit

Optimised for seasonal performance providing up to 15% improvement in efficiency over YJM-EP High COP models
Automatic refrigerant temperature control function for even further efficiency and comfort, with optional external change over control signal
Branch pipes feeding indoor units
New and improved high efficiency inverter driven compressor with very low start currents
No requirement for plant rooms or bulky service shafts
Pipe run of 165m, with a total system pipe length of 1000m, with improved indoor unit height difference and furthest indoor unit pipe lengths
100% inverter control
High Sensible Cooling Function - by raising the off coil temperature, a 10% increase in sensible cooling capacity
over standard operation is achievable, the result being greater comfort for occupants
High Performance Heating Mode for low ambient conditions

MODEL REFERENCE
CAPACITY (kW)

POWER INPUT (kW)

Heating (nominal)
Cooling (nominal)
High Performance Heating (UK)
COP Priority Heating (UK)
Cooling (UK)
Heating (nominal)
Cooling (nominal)
High Performance Heating (UK)
COP Priority Heating (UK)
Cooling (UK)

COP / EER (nominal)


SCOP / SEER
Max No. OF CONNECTABLE INDOOR UNITS
Max CONNECTABLE CAPACITY
AIRFLOW (m3/min)
High
SOUND PRESSURE LEVEL (dBA)
SOUND POWER LEVEL (dBA)
WEIgHT (kg)
DIMENSIONS (mm)
Width
Depth
(1650mm without legs)
Height
ELECTRICAL SUPPLY *
PHASE*
STARTINg CURRENT (A)*
NOMINAL SYSTEM RUNNINg CURRENT (A)* Heating / Cooling
gUARANTEED OPERATINg RANgE (C) Heating / Cooling
FUSE RATINg (MCB sizes BS EN 60947-2) - (A)*
MAINS CABLE No. Cores*

PUHY-EP200YKM-A

PUHY-EP250YKM-A

PUHY-EP300YKM-A

PUHY-EP400YSKM-A

PUHY-EP450YSKM-A

25.0
22.4
25.0
22.8
21.3
5.76
5.50
6.68
5.18
3.19
4.34 / 4.07
5.94 / 8.96
17
50~130% OU Capacity
175
57
77
201
920
740
1710
380-415v, 50Hz
Three
8
8.9 / 8.5
-20~15.5 / -5~46
1 x 20
4

31.5
28.0
31.5
28.7
26.6
7.50
6.89
8.70
6.75
4.00
4.20 / 4.06
5.75 / 8.75
21
50~130% OU Capacity
175
60
80
229
1220
740
1710
380-415v, 50Hz
Three
8
11.5 / 10.6
-20~15.5 / -5~46
1 x 20
4

37.5
33.5
35.6
32.3
31.5
9.30
8.17
11.25
8.28
5.29
4.03 / 4.10
5.59 / 7.89
26
50~130% OU Capacity
320
61
81
314
1750
740
1710
380-415v, 50Hz
Three
8
14.3 / 12.6
-20~15.5 / -5~46
1 x 25
4

50.0
45.0
47.5
43.0
42.3
12.3
11.65
14.68
10.80
7.54
4.12 / 3.86
5.75 / 8.18
34
50~130% OU Capacity
175 / 175
60
80
201 + 201
920 + 920
740
1710
380-415v, 50Hz
Three
8/8
18.7 / 18
-20~15.5 / -5~46
1 x 20 / 1 x 20
4

56.0
50.0
50.7
48.7
46.0
13.82
12.95
14.51
11.61
8.12
4.05 / 3.86
5.74 / 7.91
39
50~130% OU Capacity
175 / 175
62
82
229 + 201
1220 + 920
740
1710
380-415v, 50Hz
Three
8/8
21.3 / 20
-20~15.5 / -5~46
1 x 20 / 1 x 20
4

Note: * A separate power supply is required for each module. Where more than one figure is quoted there are multiple modules.

PIPING REStRICtIONS
TOTAL PIPINg LENgTH
FURTHEST PIPINg LENgTH
FURTHEST PIPINg LENgTH AFTER 1st BRANCH
BETWEEN INDOOR AND OUTDOOR UNITS - HEIgHT
BETWEEN INDOOR AND INDOOR UNITS - HEIgHT

PUHY-EP200-450Y(S)KM-A
1000m max
165m max
40m*1 max
50 max (40m max if outdoor installed below)
15m*2 max

Notes: *1 90m is available. When the piping length is 40m or longer, use the one size larger liquid pipe between the first joint all the way to all indoor units greater than 40m from first joint.
*2 30m is available. When the piping length is 15m or longer, use the one size larger liquid pipe between the first joint all the way to all indoor units greater than 15m from first joint.

Product Dimensions

PUHY-EP250YKM-A

150

740

600=150X4

Upper View

19.5

1181
1220

19.5

19.5

49
19.5

Discharge air

Control box

Side View

586

Side View

60
57

586

20

60
57

740

920

Intake
air

1650

30

Fan box

To indoor unit
Liquid Twinning pipe <optional parts>

586

60
57

223

172

217

223

20
586

60
57

75
541
562

58
140

Sling hole

Detachable leg
(front and back, 3 points)

Front View

PUHY-EP450YSKM-A
Front View
1220

Discharge air

Intake
air

20

20

Side View

740

920

Outdoor unit 2

172

54

60
57

Outdoor unit 1

1710

(60)

Intake
air

30

920

Outdoor unit 2

Intake
air

Intake
air

Intake
air

To indoor unit
Liquid Twinning pipe <optional parts>

Detachable leg

Detachable leg
To indoor unit
Gas Twinning pipe <optional parts>

Air Conditioning
1.5.25 1.121

Sling hole
Detachable leg
(front and back, 2 points)

Side View

1650

1710

Outdoor unit 1

75
58
140

Front View

Front View

Discharge air

1710

217

251
272

Product Dimensions

PUHY-EP400YSKM-A

Side View

Service
panel

(60)

20

20

172
222

172
222

60
57

89

Sling hole
Detachable leg
(front and back, 2 points)

Front View

Product Dimensions

Service panel
Refrigerant service valve
<liquid>
Refrigerant service valve
<gas>

(60)

58
140

(60)

201
222

57

(60)

60

(60)

20

Service panel
Refrigerant service valve
<liquid>
Refrigerant service valve
<gas>

1650

57

(60)

60

(60)

20
586

(60)

20

(60)

57

89

54

217

222

172

222

172

54

75
60

Intake
air

Intake
air

77

Service
panel

Refrigerant service valve


<liquid>
Refrigerant service valve
<gas>

Intake
air

Intake
air

77

Refrigerant service valve


<liquid>
Refrigerant service valve
<gas>

1347

1650

1710

1347

Service
panel

Refrigerant service valve


<liquid>
Refrigerant service valve
<gas>
77

Refrigerant service valve


<liquid>
Refrigerant service valve
<gas>

Intake
air

Intake
air

Intake
air

1650

Control box

Control box

Intake
air

1710

Con

303

303

303

Control box

Intake
air

19.5

1750

Discharge air

Intake
air

831

831

harge air

(60)

Discharge air

1347

ir

89

881
920

19.5
Discharge air

70

70

70

150

740

600=1504

Upper View

600=150X4

Upper View

PUHY-EP300YKM-A

740

Product Dimensions

PUHY-EP200YKM-A

217

Product Dimensions

To indoor unit
Gas Twinning pipe <optional parts>

Y Series High COP (8-18hp) - Heat Pump Outdoor Unit

1.5.26

Y Series High COP


(20-24hp)

New and Improved for even higher efficiency


The City Multi Y Series makes use of a two pipe refrigerant circuit throughout, with branch pipes feeding indoor units,
allowing manual changeover from cooling to heating to ensure that a constant indoor climate is maintained.

Key Features

Heat Pump Outdoor Unit

Optimised for seasonal performance providing up to 15% improvement in efficiency over YJM-EP High COP models
Automatic refrigerant temperature control function for even further efficiency and comfort, with optional external change over control signal
Branch pipes feeding indoor units
New and improved high efficiency inverter driven compressor with very low start currents
No requirement for plant rooms or bulky service shafts
Pipe run of 165m, with a total system pipe length of 1000m, with improved indoor unit height difference and furthest indoor unit pipe lengths
100% inverter control
High Sensible Cooling Function - by raising the off coil temperature, a 10% increase in sensible cooling capacity
over standard operation is achievable, the result being greater comfort for occupants
High Performance Heating Mode for low ambient conditions

MODEL REFERENCE
CAPACITY (kW)

POWER INPUT (kW)

Heating (nominal)
Cooling (nominal)
High Performance Heating (UK)
COP Priority Heating (UK)
Cooling (UK)
Heating (nominal)
Cooling (nominal)
High Performance Heating (UK)
COP Priority Heating (UK)
Cooling (UK)

COP / EER (nominal)


SCOP / SEER
Max No. OF CONNECTABLE INDOOR UNITS
Max CONNECTABLE CAPACITY
High
AIRFLOW (m3/min)
SOUND PRESSURE LEVEL (dBA)
SOUND POWER LEVEL (dBA)
WEIgHT (kg)
DIMENSIONS (mm)
Width
Depth
(1650mm without legs)
Height
ELECTRICAL SUPPLY *
PHASE*
STARTINg CURRENT (A)*
NOMINAL SYSTEM RUNNINg CURRENT (A)* Heating / Cooling
gUARANTEED OPERATINg RANgE (C) Heating / Cooling
FUSE RATINg (MCB sizes BS EN 60947-2) - (A)*
MAINS CABLE No. Cores*

PUHY-EP500YSKM-A

PUHY-EP550YSKM-A

PUHY-EP600YSKM-A

63.0
56.0
57.0
54.8
51.5
15.86
14.43
16.65
13.32
9.05
3.97 / 3.88
5.67 / 8.22
43
50~130% OU Capacity
320 / 175
62.5
82.5
314 + 201
1750 + 920
740
1710
380-415v, 50Hz
Three
8/8
24.5 / 22.3
-20~15.5 / -5~46
1 x 25 / 1 x 20
4

69.0
63.0
62.4
60.0
58.0
17.69
16.27
18.57
14.86
10.20
3.9 / 3.87
5.49 / 8.21
47
50~130% OU Capacity
320 / 175
63.5
83.5
314 + 229
1750 + 1220
740
1710
380-415v, 50Hz
Three
8/8
27.3 / 25.1
-20~15.5 / -5~46
1 x 25 / 1 x 20
4

76.5
69.0
69.2
66.6
63.5
20.02
17.73
21.02
16.82
11.12
3.82 / 3.89
5.38 / 8.25
50
50~130% OU Capacity
320 / 320
64
84
314 + 314
1750 + 1750
740
1710
380-415v, 50Hz
Three
8/8
30.9 / 27.4
-20~15.5 / -5~46
1 x 25 / 1 x 25
4

Note: * A separate power supply is required for each module. Where more than one figure is quoted there are multiple modules.

PIPING REStRICtIONS
TOTAL PIPINg LENgTH
FURTHEST PIPINg LENgTH
FURTHEST PIPINg LENgTH AFTER 1st BRANCH
BETWEEN INDOOR AND OUTDOOR UNITS - HEIgHT
BETWEEN INDOOR AND INDOOR UNITS - HEIgHT

PUHY-EP500-600YSKM-A
1000m max
165m max
40m*1 max
50 max (40m max if outdoor installed below)
15m*2 max

Notes: *1 90m is available. When the piping length is 40m or longer, use the one size larger liquid pipe between the first joint all the way to all indoor units greater than 40m from first joint.
*2 30m is available. When the piping length is 15m or longer, use the one size larger liquid pipe between the first joint all the way to all indoor units greater than 15m from first joint.

Product Dimensions

PUHY-EP500YSKM-A

Side View

Front View

740

Side View

1750

Discharge air

30

920

Outdoor unit 2

Front View

740

1750

Discharge air

Outdoor unit 1

1710

1650

Intake
air

(60)

To indoor unit
Liquid Twinning pipe <optional parts>

Detachable leg

Detachable leg

To indoor unit
Gas Twinning pipe <optional parts>

Product Dimensions

Intake
air

Intake
air

Intake
air

(60)

1710

Outdoor unit 1

Intake
air

PUHY-EP550YSKM-A

30

1220

Outdoor unit 2

1650

Product Dimensions

Intake
air

To indoor unit
Liquid Twinning pipe <optional parts>
To indoor unit
Gas Twinning pipe <optional parts>

PUHY-EP600YSKM-A

Side View

Front View

1750

740

Outdoor unit 1

1750

Outdoor unit 2

1650

1710

Discharge air

30

Intake
air

Intake
air

Detachable leg

To indoor unit
Liquid Twinning pipe <optional parts>
To indoor unit
Gas Twinning pipe <optional parts>

(60)

Intake
air

Air Conditioning
1.5.27 1.121

Y Series High COP (20-24hp) - Heat Pump Outdoor Unit

1.5.28

Y Series High COP


(26-30hp)

New and Improved for even higher efficiency


The City Multi Y Series makes use of a two pipe refrigerant circuit throughout, with branch pipes feeding indoor units,
allowing manual changeover from cooling to heating to ensure that a constant indoor climate is maintained.

Key Features

Heat Pump Outdoor Unit

Optimised for seasonal performance providing up to 15% improvement in efficiency over YJM-EP High COP models
Automatic refrigerant temperature control function for even further efficiency and comfort, with optional external change over control signal
Branch pipes feeding indoor units
New and improved high efficiency inverter driven compressor with very low start currents
No requirement for plant rooms or bulky service shafts
Pipe run of 165m, with a total system pipe length of 1000m, with improved indoor unit height difference and furthest indoor unit pipe lengths
100% inverter control
High Sensible Cooling Function - by raising the off coil temperature, a 10% increase in sensible cooling capacity
over standard operation is achievable, the result being greater comfort for occupants
High Performance Heating Mode for low ambient conditions

MODEL REFERENCE
CAPACITY (kW)

POWER INPUT (kW)

Heating (nominal)
Cooling (nominal)
High Performance Heating (UK)
COP Priority Heating (UK)
Cooling (UK)
Heating (nominal)
Cooling (nominal)
High Performance Heating (UK)
COP Priority Heating (UK)
Cooling (UK)

COP / EER (nominal)


SCOP / SEER
Max No. OF CONNECTABLE INDOOR UNITS
Max CONNECTABLE CAPACITY
AIRFLOW (m3/min)
High
SOUND PRESSURE LEVEL (dBA)
SOUND POWER LEVEL (dBA)
WEIgHT (kg)
DIMENSIONS (mm)
Width
Depth
(1650mm without legs)
Height
ELECTRICAL SUPPLY *
PHASE*
STARTINg CURRENT (A)*
NOMINAL SYSTEM RUNNINg CURRENT (A)* Heating / Cooling
gUARANTEED OPERATINg RANgE (C) Heating / Cooling
FUSE RATINg (MCB sizes BS EN 60947-2) - (A)*
MAINS CABLE No. Cores*

PUHY-EP650YSKM-A

PUHY-EP700YSKM-A

PUHY-EP750YSKM-A

81.5
73.0
73.8
70.9
67.2
20.02
18.91
21.02
16.82
11.86
4.07 / 3.86
5.73 / 8.18
50
50~130% OU Capacity
175 / 175 / 175
63
83
229 + 201 + 201
1220 + 920 + 920
740
1710
380-415v, 50Hz
Three
8/8/8
30.9 / 29.2
-20~15.5 / -5~46
1 x 20 / 1 x 20 / 1 x 20
4

88.0
80.0
88.0
76.6
73.6
21.89
20.67
25.39
18.83
13.37
4.02 / 3.87
5.87 / 7.98
50
50~130% OU Capacity
320 / 175 / 175
63.5
83.5
314 + 201 + 201
1750 + 920 + 920
740
1710
380-415v, 50Hz
Three
8/8/8
33.8 / 31.9
-20~15.5 / -5~46
1 x 25 / 1 x 20 / 1 x 20
4

95.0
85.0
95.0
82.7
78.2
23.86
21.96
27.68
20.52
14.21
3.98 / 3.87
5.82 / 7.98
50
50~130% OU Capacity
320 / 175 / 175
64.5
84.5
314 + 229 + 201
1750 + 1220 + 920
740
1710
380-415v, 50Hz
Three
8/8/8
36.8 / 33.9
-20~15.5 / -5~46
1 x 25 / 1 x 20 / 1 x 20
4

Note: * A separate power supply is required for each module. Where more than one figure is quoted there are multiple modules.

PIPING REStRICtIONS
TOTAL PIPINg LENgTH
FURTHEST PIPINg LENgTH
FURTHEST PIPINg LENgTH AFTER 1st BRANCH
BETWEEN INDOOR AND OUTDOOR UNITS - HEIgHT
BETWEEN INDOOR AND INDOOR UNITS - HEIgHT

PUHY-EP650-750YSKM-A
1000m max
165m max
40m*1 max
50 max (40m max if outdoor installed below)
15m*2 max

Notes: *1 90m is available. When the piping length is 40m or longer, use the one size larger liquid pipe between the first joint all the way to all indoor units greater than 40m from first joint.
*2 30m is available. When the piping length is 15m or longer, use the one size larger liquid pipe between the first joint all the way to all indoor units greater than 15m from first joint.

Product Dimensions

PUHY-EP650YSKM-A
Front View

920

920

740

1750

Discharge air

Outdoor unit 1

Intake
air

Intake
air

To indoor unit
Liquid Twinning pipe 1 <optional parts>

Liquid Twinning pipe 2 <optional parts>

Gas Twinning pipe 1 <optional parts>

Gas Twinning pipe 2 <optional parts>

30

920

Outdoor unit 2

30

920

Outdoor unit 3

Intake
air

Intake
air

(60)

Intake
air

Detachable leg

Front View

Outdoor unit 3

30

Outdoor unit 2

(60)

Intake
air

30

1650

1220

Outdoor unit 1

1710

740

Discharge air

Side View

PUHY-EP700YSKM-A

1650

Side View

1710

Product Dimensions

Detachable leg

To indoor unit
Liquid Twinning pipe 1 <optional parts>

Liquid Twinning pipe 2 <optional parts>

Gas Twinning pipe 1 <optional parts>

Gas Twinning pipe 2 <optional parts>

To indoor unit

To indoor unit

Product Dimensions

PUHY-EP750YSKM-A

Side View

Front View

740

1750

Discharge air

30

1220

Outdoor unit 2

30

920

Outdoor unit 3

Intake
air

Intake
air

(60)

Intake
air

1650

1710

Outdoor unit 1

Detac

Detachable leg

Air Conditioning
1.5.29 1.121

Liquid Twinning pipe 1 <optional parts>

To indoor unit
Liquid Twinning pipe 2 <optional parts>

Gas Twinning pipe 1 <optional parts>

To indoor unit
Gas Twinning pipe 2 <optional parts>

Y Series High COP (26-30hp) - Heat Pump Outdoor Unit

1.5.30

Y Series High COP


(32-36hp)

New and Improved for even higher efficiency


The City Multi Y Series makes use of a two pipe refrigerant circuit throughout, with branch pipes feeding indoor units,
allowing manual changeover from cooling to heating to ensure that a constant indoor climate is maintained.

Key Features

Heat Pump Outdoor Unit

Optimised for seasonal performance providing up to 15% improvement in efficiency over YJM-EP High COP models
Automatic refrigerant temperature control function for even further efficiency and comfort, with optional external change over control signal
Branch pipes feeding indoor units
New and improved high efficiency inverter driven compressor with very low start currents
No requirement for plant rooms or bulky service shafts
Pipe run of 165m, with a total system pipe length of 1000m, with improved indoor unit height difference and furthest indoor unit pipe lengths
100% inverter control
High Sensible Cooling Function - by raising the off coil temperature, a 10% increase in sensible cooling capacity
over standard operation is achievable, the result being greater comfort for occupants
High Performance Heating Mode for low ambient conditions

MODEL REFERENCE
CAPACITY (kW)

POWER INPUT (kW)

Heating (nominal)
Cooling (nominal)
High Performance Heating (UK)
COP Priority Heating (UK)
Cooling (UK)
Heating (nominal)
Cooling (nominal)
High Performance Heating (UK)
COP Priority Heating (UK)
Cooling (UK)

COP / EER (nominal)


SCOP / SEER
Max No. OF CONNECTABLE INDOOR UNITS
Max CONNECTABLE CAPACITY
AIRFLOW (m3/min)
High
SOUND PRESSURE LEVEL (dBA)
SOUND POWER LEVEL (dBA)
WEIgHT (kg)
DIMENSIONS (mm)
Width
Depth
(1650mm without legs)
Height
ELECTRICAL SUPPLY *
PHASE*
STARTINg CURRENT (A)*
NOMINAL SYSTEM RUNNINg CURRENT (A)* Heating / Cooling
gUARANTEED OPERATINg RANgE (C) Heating / Cooling
FUSE RATINg (MCB sizes BS EN 60947-2) - (A)*
MAINS CABLE No. Cores*

PUHY-EP800YSKM-A

PUHY-EP850YSKM-A

PUHY-EP900YSKM-A

100.0
90.0
100.0
87.0
82.8
25.51
23.19
29.59
21.94
15.00
3.92 / 3.88
5.73 / 8.02
50
50~130% OU Capacity
320 / 320 / 175
65
85
314 + 314 + 201
1750 + 1750 + 920
740
1710
380-415v, 50Hz
Three
8/8/8
39.4 / 35.8
-20~15.5 / -5~46
1 x 25 / 1 x 25 / 1 x 20
4

108.0
96.0
102.6
95.0
88.8
27.83
24.74
33.67
23.38
15.09
3.88 / 3.88
5.43 / 8.42
50
50~130% OU Capacity
320 / 320 / 175
65.5
85.5
314 + 314 + 229
1750 + 1750 + 1220
740
1710
380-415v, 50Hz
Three
8/8/8
43.0 / 38.2
-20~15.5 / -5~46
1 x 25 / 1 x 25 / 1 x 20
4

113.0
101.0
107.4
99.4
92.9
29.58
25.96
35.79
24.85
15.84
3.82 / 3.89
5.35 / 8.44
50
50~130% OU Capacity
320 / 320 / 320
66
86
314 + 314 + 314
1750 + 1750 + 1750
740
1710
380-415v, 50Hz
Three
8/8/8
45.7 / 40.1
-20~15.5 / -5~46
1 x 25 / 1 x 25 / 1 x 25
4

Note: * A separate power supply is required for each module. Where more than one figure is quoted there are multiple modules.

PIPING REStRICtIONS
TOTAL PIPINg LENgTH
FURTHEST PIPINg LENgTH
FURTHEST PIPINg LENgTH AFTER 1st BRANCH
BETWEEN INDOOR AND OUTDOOR UNITS - HEIgHT
BETWEEN INDOOR AND INDOOR UNITS - HEIgHT

PUHY-EP800-900YSKM-A
1000m max
165m max
40m*1 max
50 max (40m max if outdoor installed below)
15m*2 max

Notes: *1 90m is available. When the piping length is 40m or longer, use the one size larger liquid pipe between the first joint all the way to all indoor units greater than 40m from first joint.
*2 30m is available. When the piping length is 15m or longer, use the one size larger liquid pipe between the first joint all the way to all indoor units greater than 15m from first joint.

Front View

Side View

30

Outdoor unit 1

1650

1710

30

920

Intake
air

Intake
air

Detachable leg

Product Dimensions
Side View

Liquid Twinning pipe 1 <optional parts>

To indoor unit
Liquid Twinning pipe 2 <optional parts>

Gas Twinning pipe 1 <optional parts>

To indoor unit
Gas Twinning pipe 2 <optional parts>

Intake
air

Outdoor unit 1

30

1750

30

Outdoor unit 2

1220

Outdoor unit 3

Intake
air

Intake
air

Detachable leg

Liquid Twinning pipe 1 <optional parts>

To indoor unit
Liquid Twinning pipe 2 <optional parts>

Gas Twinning pipe 1 <optional parts>

To indoor unit
Gas Twinning pipe 2 <optional parts>

PUHY-EP900YSKM-A

Front View

1750

740

Discharge air

1650

1710

Outdoor unit 1

30

1750

30

Outdoor unit 2

Detachable leg

Liquid Twinning pipe 1 <optional parts>


Gas Twinning pipe 1 <optional parts>

Air Conditioning
1.5.31 1.121

1750

Outdoor unit 3

Intake
air

Intake
air

(60)

Intake
air

1750

740

Discharge air

Outdoor unit 3

(60)

Intake
air

1750

Outdoor unit 2

Front View

1650

1750

740

Discharge air

PUHY-EP850YSKM-A

(60)

Side View

Product Dimensions

PUHY-EP800YSKM-A

1710

Product Dimensions

To indoor unit
Liquid Twinning pipe 2 <optional parts>
To indoor unit
Gas Twinning pipe 2 <optional parts>

Y Series High COP (32-36hp) - Heat Pump Outdoor Unit

1.5.32

Y Series Zubadan
(8-20hp)

Zubadan sets a new standard in heating performance


The new City Multi Zubadan heat pumps achieve an excellent heating performance even when the outdoor air temperature
is as low as -25C.

Key Features

Heat Pump Outdoor Unit

Stable Heating Performance - full heating capacity at an outdoor temperature of -15C.


A 40% capacity improvement over the standard YJM-A model
Expanded Heating Operation - will work effectively even when the outdoor ambient air temperature is -25C
Stable Operation - utilising the new Flash Injection Circuit the Zubadan models have reduced defrost times
and can provide continuous heating for up to 250 mins
Quick Start-Up - full heating capacity is achieved in about 20 mins, improving comfort levels
Energy-saving inverter driven outdoor compressor units with very low start currents
100% inverter control
High Sensible Cooling Function - by raising the off coil temperature, a 10% increase in sensible cooling capacity
over standard operation is achievable, the result being greater comfort for occupants

MODEL REFERENCE
CAPACITY (kW)

POWER INPUT (kW)

Heating (nominal)
Cooling (nominal)
Heating (UK)
Cooling (UK)
Heating (nominal)
Cooling (nominal)
Heating (UK)
Cooling (UK)

COP / EER (nominal)


SCOP / SEER
MAx No. OF CONNECTABLE INDOOR UNITS
AIRFLOW (m3/min)
High
SOUND PRESSURE LEVEL (dBA)
SOUND POWER LEVEL (dBA)
WEIgHT (kg)
DIMENSIONS (mm)
Width
Depth
(1650mm without legs)
Height
ELECTRICAL SUPPLY*
PHASE*
STARTINg CURRENT (A)*
NOMINAL SYSTEM
Heating
RUNNINg CURRENT (A)* Cooling
FUSE RATINg (MCB sizes BS EN 60947-2) - (A)*
MAINS CABLE No. Cores*
OPERATINg RANgE (Outdoor temp CWB) Heating

PUHY-HP200YHM-A

PUHY-HP250YHM-A

PUHY-HP400YSHM-A

PUHY-HP500YSHM-A

25.0
22.4
28.0
19.9
6.52
6.40
11.02
4.99
3.83 / 3.50
- / 3.50
17
225
56
73
220
920
760
1710
380-415v, 50Hz
Three
8
10.0
9.8
1 x 32
4 + earth
-25 - 15.5C

31.5
28.0
35.3
24.9
8.94
9.06
15.11
7.07
3.52 / 3.09
- / 3.15
21
225
57
74
220
920
760
1710
380-415v, 50Hz
Three
8
13.8
14.0
1 x 32
4 + earth
-25 - 15.5C

50.0
45.0
56.0
40.1
13.35
12.86
22.56
10.03
3.74 / 3.49
- / 3.62
34
225 / 225
59
76
220 + 220
920 + 920
760
1710
380-415v, 50Hz
Three
8/8
20.6
19.8
1 x 32 / 1 x 32
4 + earth
-25 - 15.5C

63.0
56.0
70.6
49.8
18.04
18.16
30.49
14.16
3.49 / 3.08
- / 3.25
43
225 / 225
60
77
220 + 220
920 + 920
760
1710
380-415v, 50Hz
Three
8/8
27.8
28.0
1 x 32 / 1 x 32
4 + earth
-25 - 15.5C

Note: * A separate power supply is required for each module. Where more than one figure is quoted there are multiple modules.

PIPING REStRICtIONS
TOTAL PIPINg LENgTH
FURTHEST PIPINg LENgTH
FURTHEST PIPINg LENgTH AFTER 1st BRANCH
BETWEEN INDOOR AND OUTDOOR UNITS - HEIgHT
BETWEEN INDOOR AND INDOOR UNITS - HEIgHT

PUHY-HP200-500Y(S)HM-A
300m max
150m max
40m max
50m max (40m max if outdoor installed below)
15m max

Product Dimensions

PUHY-HP200/250YHM-A

Side View

Front View

Upper View

240

Discharge air

760

Control box

1710

Service
panel

1650

Refrigerant service
valve <liquid>

1410

Intake
air

Intake
air

Intake
air

920

760

25

72

132 88

90

60
55

204
251

98
102

60

25

A
60
55

60

54

Refrigerant service
valve <gas>

Detachable leg
(front and back,2 points)

Product Dimensions

PUHY-HP400/500YSHM-A

Side View

Front View
30

920

Outdoor unit 2

1650

920

Outdoor unit 1

1710

760

Discharge air

Intake
air

60

Intake
air

Detachable leg

Intake
air

To indoor unit
Liquid Twinning pipe<optional parts>
To indoor unit
Gas Twinning pipe<optional parts>

Air Conditioning
1.5.33 1.121

Y Series Zubadan (8-20hp) - Heat Pump Outdoor Unit

1.5.34

Y Series
Replace Multi
(8-26hp)
Heat Pump Outdoor Unit

Enables the replacement of VRF systems, whilst utilising existing R22 / R407c pipework
The latest VRF Replace Multi from Mitsubishi Electric is specifically designed for the maturing refurbishment sector, enabling the reuse of existing
R22 / R407c pipework, whilst also allowing the upgrade to some of the most efficient systems available in the market. Replace Multi will clean the
existing pipework during commissioning, removing any deposits and R22 mineral oil that would have ordinarily meant that new pipework would
have been called for. The implications of this are significant savings on cost and time, whilst also minimising any potential disruption.

Key Features
tried and tested technology
Efficient use of existing resources - refrigerant piping, control and power wiring and less waste materials
Increased energy efficiency - up to 105% more efficient than an old Mitsubishi Electric R22 system (size P200)
Reduced installation costs of up to 55%
Reduced CO2 emissions and running cost savings of up to 45%
Reduced installation time with minimised disruption
Ability to replace many non Mitsubishi Electric systems
High Performance Heating Mode for low ambient conditions
Additional function to protect existing pipes
For more information on the Case for Replace, please visit the website: replace.mitsubishielectric.co.uk

MODEL REFERENCE
CAPACITY (kW)

POWER INPUT (kW)

Heating (nominal)
Cooling (nominal)
High Performance Heating (UK)
COP Priority Heating (UK)
Cooling (UK)
Heating (nominal)
Cooling (nominal)
High Performance Heating (UK)
COP Priority Heating (UK)
Cooling (UK)

COP / EER (nominal)


SCOP / SEER
MAx No. OF CONNECTABLE INDOOR UNITS
AIRFLOW (m3/min)
High
SOUND PRESSURE LEVEL (dBA)
SOUND POWER LEVEL (dBA)
WEIgHT (kg)
DIMENSIONS (mm)
Width
Depth
(1650mm without legs)
Height
ELECTRICAL SUPPLY*
PHASE*
STARTINg CURRENT (A)*
NOMINAL SYSTEM
Heating
RUNNINg CURRENT (A)* Cooling
FUSE RATINg (MCB sizes BS EN 60947-2) - (A)*
MAINS CABLE No. Cores*

PUHYRP200YJM-B

PUHYRP250YJM-B

PUHYRP300YJM-B

PUHYPUHYPUHYPUHYPUHYPUHYPUHYRP350YJM-B RP400YSJM-B RP450YSJM-B RP500YSJM-B RP550YSJM-B RP600YSJM-B RP650YSJM-B

31.5
25.0
28.0
22.4
31.5
25.0
28.7
22.8
24.9
19.9
7.22
5.69
7.62
5.68
9.31
7.34
7.15
5.63
5.94
4.43
4.36 / 3.67
4.39 / 3.94
- / 7.05
- / 6.42
21
17
185
185
57
56
77
76
255
230
920
920
760
760
1710
1710
380-415v, 50Hz 380-415v, 50Hz
Three
Three
8
8
8.7
12.1
8.7
12.7
1 x 20
1 x 20
4 + earth
4 + earth

37.5
33.5
36.0
32.6
31.5
9.42
8.98
12.43
9.14
7.36
3.98 / 3.73
- / 5.65
26
185
59
79
255
920
760
1710
380-415v, 50Hz
Three
8
15.2
14.4
1 x 25
4 + earth

45.0
50.0
56.0
63.0
69.0
76.5
81.5
40.0
45.0
50.0
56.0
63.0
69.0
73.0
43.2
48.0
53.8
60.5
66.2
73.4
78.2
39.2
43.5
48.7
54.8
60.0
66.6
70.9
37.6
42.3
46.0
51.5
58.0
63.5
67.2
12.60
11.38
12.81
14.44
16.62
19.22
21.73
11.79
11.87
13.77
15.68
17.50
18.59
21.09
16.63
14.57
16.40
18.48
21.27
24.60
27.81
12.22
11.04
11.66
13.14
15.12
17.49
19.77
9.67
9.73
9.64
10.98
12.25
13.01
14.76
3.57 / 3.39
4.39 / 3.79
4.37 / 3.63
4.36 / 3.57
4.15 / 3.60
3.98 / 3.71
3.75 / 3.46
- / 5.46
- / 5.37
- / 5.67
- / 7.71
- / 6.00
- / 5.90
- / 5.50
30
32
32
32
32
32
32
185
185 / 185
185 / 185
185 / 185
185 / 185
185 / 185
185 / 185
60
59
59.5
60
61
62
62.5
80
79
79.5
80
81
82
82.5
255
230 + 230
255 + 230
255 + 255
255 + 255
255 + 255
255 + 255
920
920 + 920
920 + 920
920 + 920
920 + 920
920 + 920
920 + 920
760
760
760
760
760
760
760
1710
1710
1710
1710
1710
1710
1710
380-415v, 50Hz 380-415v, 50Hz 380-415v, 50Hz 380-415v, 50Hz 380-415v, 50Hz 380-415v, 50Hz 380-415v, 50Hz
Three
Three
Three
Three
Three
Three
Three
8
8+8
8+8
8+8
8+8
8+8
8+8
20.2
17.5
20.7
24.2
27.3
31.1
35.0
18.9
18.3
22.2
26.2
28.7
30.8
34.0
1 x 32
1 x 20 / 1 x 20 1 x 20 / 1 x 20 1 x 20 / 1 x 20 1 x 25 / 1 x 20 1 x 25 / 1 x 25 1 x 32 / 1 x 25
4 + earth
4 + earth
4 + earth
4 + earth
4 + earth
4 + earth
4 + earth

Note: * A separate power supply is required for each module. Where more than one figure is quoted there are multiple modules.

PIPING REStRICtIONS
TOTAL PIPINg LENgTH
FURTHEST PIPINg LENgTH
FURTHEST PIPINg LENgTH AFTER 1st BRANCH
BETWEEN INDOOR AND OUTDOOR UNITS - HEIgHT
BETWEEN INDOOR AND INDOOR UNITS - HEIgHT

PUHY-RP200-650Y(S)JM-B
300m max (250m for size 600-650)
120m max
40m max
50m max (40m max if outdoor installed below)
15m max

Product Dimensions

PUHY-RP200/250/300/350YJM-B

Side View

Front View

Upper View

240

Discharge air

760

Control box

Intake
air

Intake
air

Intake
air

1710

Service
panel

1650

valve <liquid>

1410

Refrigerant service
920

Refrigerant service

72

132 88

204
251

98
102

760

Product Dimensions

Detachable leg
(front and back, 2 points)

PUHY-RP400/450/500/550/600/650YSJM-B

Side View

Front View
920

760
Discharge air

30

920

Outdoor unit 2

1650

1710

Outdoor unit 1

Intake
air

(60)

Intake
air

Air Conditioning
1.5.35 1.121

(60)

55

90

60
25

25

60
55

(60)

54

valve <gas>

Detachable leg

Intake
air

To indoor unit
Liquid Twinning pipe <optional parts>
To indoor unit
Gas Twinning pipe <optional parts>

Y Series Replace Multi (8-26hp) - Heat Pump Outdoor Unit

1.5.36

Y Series
Replace Multi
(28-36hp)
Heat Pump Outdoor Unit

Enables the replacement of VRF systems, whilst utilising existing R22 / R407c pipework
The latest VRF Replace Multi from Mitsubishi Electric is specifically designed for the maturing refurbishment sector, enabling the reuse of existing
R22 / R407c pipework, whilst also allowing the upgrade to some of the most efficient systems available in the market. Replace Multi will clean
the existing pipework during commissioning, removing any deposits and R22 mineral oil that would have ordinarily meant that new pipework
would have been called for. The implications of this are significant savings on cost and time, whilst also minimising any potential disruption.

Key Features
tried and tested technology
Efficient use of existing resources - refrigerant piping, control and power wiring and less waste materials
Reduced installation costs of up to 55%
Reduced CO2 emissions and running cost savings of up to 45%
Reduced installation time with minimised disruption
Ability to replace many non Mitsubishi Electric systems
High Performance Heating Mode for low ambient conditions
Additional function to protect existing pipes
For more information on the Case for Replace, please visit the website: replace.mitsubishielectric.co.uk

MODEL REFERENCE
CAPACITY (kW)

POWER INPUT (kW)

Heating (nominal)
Cooling (nominal)
High Performance Heating (UK)
COP Priority Heating (UK)
Cooling (UK)
Heating (nominal)
Cooling (nominal)
High Performance Heating (UK)
COP Priority Heating (UK)
Cooling (UK)

COP / EER (nominal)


SCOP / SEER
MAx No. OF CONNECTABLE INDOOR UNITS
High
AIRFLOW (m3/min)
SOUND PRESSURE LEVEL (dBA)
SOUND POWER LEVEL (dBA)
WEIgHT (kg)
DIMENSIONS (mm)
Width
Depth
(1650mm without legs)
Height
ELECTRICAL SUPPLY*
PHASE*
STARTINg CURRENT (A)*
NOMINAL SYSTEM
Heating
RUNNINg CURRENT (A)* Cooling
FUSE RATINg (MCB sizes BS EN 60947-2) - (A)*
MAINS CABLE No. Cores*

PUHY-RP700YSJM-B

PUHY-RP750YSJM-B

PUHY-RP800YSJM-B

PUHY-RP850YSJM-B

PUHY-RP900YSJM-B

88.0
80.0
84.5
76.6
73.6
20.13
22.22
26.57
18.72
18.66
4.37 / 3.60
- / 6.03
32
185 / 185 / 185
61.5
81.5
255 + 255 + 230
920 + 920 + 920
760
1710
380-415v, 50Hz
Three
8+8+8
33.0
36.4
1 x 20 / 1 x 20 / 1 x 20
4 + earth

95.0
85.0
91.2
82.7
78.2
21.78
24.14
28.75
20.26
20.28
4.36 / 3.52
- / 6.23
32
185 / 185 / 185
62
82
255 + 255 + 255
920 + 920 + 920
760
1710
380-415v, 50Hz
Three
8+8+8
36.5
39.7
1 x 20 / 1 x 20 / 1 x 20
4 + earth

100.0
90.0
96.0
87.0
82.8
23.75
25.49
31.35
22.09
21.41
4.21 / 3.53
- / 5.92
32
185 / 185 / 185
62.5
82.5
255 + 255 + 255
920 + 920 + 920
760
1710
380-415v, 50Hz
Three
8+8+8
39.3
42.0
1 x 25 / 1 x 20 / 1 x 20
4 + earth

108.0
96.0
103.7
94.0
88.3
26.47
27.11
34.15
24.09
22.77
4.08 / 3.54
- / 5.89
32
185 / 185 / 185
63.5
83.5
255 + 255 + 255
920 + 920 + 920
760
1710
380-415v, 50Hz
Three
8+8+8
43.2
44.1
1 x 25 / 1 x 25 / 1 x 20
4 + earth

113.0
101.0
108.5
98.3
92.9
28.39
28.29
36.62
25.83
23.76
3.98 / 3.57
- / 5.60
32
185 / 185 / 185
64
84
255 + 255 + 255
920 + 920 + 920
760
1710
380-415v, 50Hz
Three
8+8+8
45.9
45.7
1 x 25 / 1 x 25 / 1 x 25
4 + earth

Note: * A separate power supply is required for each module. Where more than one figure is quoted there are multiple modules.

PIPING REStRICtIONS
TOTAL PIPINg LENgTH
FURTHEST PIPINg LENgTH
FURTHEST PIPINg LENgTH AFTER 1st BRANCH
BETWEEN INDOOR AND OUTDOOR UNITS - HEIgHT
BETWEEN INDOOR AND INDOOR UNITS - HEIgHT

PUHY-RP700-900YSJM-B
250m max
100m max
40m max
50m max (40m max if outdoor installed below)
15m max

Product Dimensions

PUHY-RP700/750/800/850/900YSJM-B

Side View

Front View
920

760
Discharge air

1650

1710

Outdoor unit 1

(60)

Intake
air

Air Conditioning
1.5.37 1.121

30

920

30

Outdoor unit 2

Outdoor unit 3

Intake
air

Detachable leg

920

Intake
air

Liquid Twinning pipe 1


<optional parts>

To indoor unit
Liquid Twinning pipe 2
<optional parts>

Gas Twinning pipe 1


<optional parts>

To indoor unit
Gas Twinning pipe 2
<optional parts>

Y Series Replace Multi (28-36hp) - Heat Pump Outdoor Unit

1.5.38

R2 Series Standard
(8-18hp)
Simultaneous Heating and
Cooling with Heat Recovery
Outdoor Unit

Setting the standard in efficiency


Throughout the year, many buildings require cooling in some areas and heating in others - even in adjacent rooms. The outstanding
City Multi R2 system meets this requirement by distributing surplus heat from cooling operations (and vice versa) to rooms where it is
needed. This efficiency can result in energy savings of up to 30% over conventional systems.

Key Features
High efficiency inverter technology, with low start currents and wrap around coil for added efficiency
Up to 45 indoor units connected to each outdoor unit
Easy to install unique 2-pipe technology means minimal disruption, quicker installation and less connections than 3 pipe equivalents
Pipe run of 165m with a total system pipe length of up to 600m
100% inverter control
High Sensible Cooling Function - by raising the off coil temperature, a 10% increase in sensible cooling capacity
over standard operation is achievable, the result being greater comfort for occupants
High Performance Heating Mode for low ambient conditions
Compact chassis for easier installation

MODEL REFERENCE
CAPACITY (kW)

POWER INPUT (kW)

Heating (nominal)
Cooling (nominal)
High Performance Heating (UK)
COP Priority Heating (UK)
Cooling (UK)
Heating (nominal)
Cooling (nominal)
High Performance Heating (UK)
COP Priority Heating (UK)
Cooling (UK)

COP / EER (nominal)


SCOP / SEER
MAx No. OF CONNECTABLE INDOOR UNITS
High
AIRFLOW (m3/min)
SOUND PRESSURE LEVEL (dBA)
SOUND POWER LEVEL (dBA)
WEIgHT (kg)
DIMENSIONS (mm)
Width
Depth
(1650mm without legs)
Height
ELECTRICAL SUPPLY*
PHASE*
STARTINg CURRENT (A)*
NOMINAL SYSTEM
Heating
RUNNINg CURRENT (A)* Cooling
FUSE RATINg (MCB sizes BS EN 60947-2) - (A)*
MAINS CABLE No. Cores*

PURY-P200YJM-A

PURY-P250YJM-A

PURY-P300YJM-A

PURY-P350YJM-A

PURY-P400YJM-A

PURY-P450YJM-A

25.0
22.4
25.0
22.8
21.3
5.69
5.18
7.17
5.63
2.98
4.39 / 4.32
4.87 / 7.27
20
185
56
76
240
920
760
1710
380-415v, 50Hz

31.5
28.0
31.5
28.7
26.6
7.32
7.05
9.22
7.25
4.05
4.30 / 3.97
4.98 / 6.99
25
185
57
77
240
920
760
1710
380-415v, 50Hz

37.5
33.5
35.6
32.3
31.5
8.78
8.67
11.77
8.52
5.59
4.27 / 3.86
5.04 / 6.42
30
185
59
79
245
920
760
1710
380-415v, 50Hz

45.0
40.0
42.8
38.7
37.6
10.89
11.33
14.59
10.56
7.31
4.13 / 3.53
4.95 / 6.32
35
225
60
80
270
1220
760
1710
380-415v, 50Hz

50.0
45.0
47.5
43.0
42.3
12.75
13.55
17.09
12.37
8.74
3.92 / 3.32
4.96 / 5.81
40
225
61
81
270
1220
760
1710
380-415v, 50Hz

56.0
50.0
50.7
48.7
46.0
14.58
14.49
16.62
13.27
9.13
3.84 / 3.45
5.13 / 6.21
45
360
62
82
320
1750
760
1710
380-415v, 50Hz

Three
8
8.7
8.0
1 x 20
4 + earth

Three
8
11.3
10.8
1 x 20
4 + earth

Three
8
13.5
13.4
1 x 25
4 + earth

Three
8
16.8
17.5
1 x 32
4 + earth

Three
8
19.7
20.9
1 x 40
4 + earth

Three
8
22.5
22.3
1 x 40
4 + earth

Note: * A separate power supply is required for each module. Where more than one figure is quoted there are multiple modules. For piping restrictions for PURY-P200-450YJM-A please see page 1.5.50

Product Dimensions

PURY-P350/400YJM-A
Upper View

760

80 150 150 150 150

Upper View

18

884
920

18

760

PURY-P200/250/300YJM-A

80 150 150 150 150


18

Discharge air

1184
1220

18

e air

240

240

Discharge air

Control box

Service
panel

77

Refrigerant service
valve <Low pressure>

221

Side View

Detachable leg
(front and back, 2 points)

25

25
760

Front View

Product Dimensions

Side View

60
55

60
55

217
146

263
25

90

60
55

(60)

263

760

58
75
140

(60)

185
201

(60)

90

60
55

(60

60
55

(60

25

235
251
271

58
75
140

Detachable leg
(front and back, 2 points)

Front View

Side View

150

760

300

80 150 150 150 150

Upper View

150

PURY-P450YJM-A

50

80

25

54

217
146

54
60
55

1710

1710

Refrigerant service
valve <Low pressure>
Refrigerant service
valve <High pressure>

77

Refrigerant service
valve <Low pressure>

Service
panel

Intake
air

Intake
air

Intake
air

1650

Refrigerant service
valve <High pressure>

1410

Refrigerant service
valve <High pressure>

1650

Intake
air

Intake
air

Intake
air

1410

Control box

(60)

Product Dimensions

831

19

831

19

1750
Discharge air

240

Discharge air

Con

Control box

Intake
air

Intake
air

Refrigerant service
valve <High pressure>

Refrigerant service
valve <High pressure>

Service
panel
1410

Service
panel
Refrigerant service
valve <Low pressure>

Refrigerant service
valve <Low pressure>

1650
1710

Intake
air

55

760

55

760

55

526
541
562

58
75
140

Detachable leg
(front and back,3 points)

(60)

146

217

263

217

60
25

25

90

60
25

25

(60)

60

(60)

54

263

77

Contactor
box

Front View

Air Conditioning
1.5.39 1.121

R2 Series Standard (8-18hp) - Heat Recovery Outdoor Unit

1.5.40

R2 Series Standard
(18-28hp)
Simultaneous Heating and
Cooling with Heat Recovery
Outdoor Unit

Setting the standard in efficiency


Throughout the year, many buildings require cooling in some areas and heating in others - even in adjacent rooms. The outstanding
City Multi R2 system meets this requirement by distributing surplus heat from cooling operations (and vice versa) to rooms where it is
needed. This efficiency can result in energy savings of up to 30% over conventional systems.

Key Features
High efficiency inverter technology, with low start currents and wrap around coil for added efficiency
Up to 50 indoor units connected to each outdoor unit
Easy to install unique 2-pipe technology means minimal disruption, quicker installation and less connections than 3 pipe equivalents
Pipe run of 165m with a total system pipe length of up to 950m
100% inverter control
High Sensible Cooling Function - by raising the off coil temperature, a 10% increase in sensible cooling capacity
over standard operation is achievable, the result being greater comfort for occupants
High Performance Heating Mode for low ambient conditions
Compact chassis for easier installation

MODEL REFERENCE
CAPACITY (kW)

POWER INPUT (kW)

Heating (nominal)
Cooling (nominal)
High Performance Heating (UK)
COP Priority Heating (UK)
Cooling (UK)
Heating (nominal)
Cooling (nominal)
High Performance Heating (UK)
COP Priority Heating (UK)
Cooling (UK)

COP / EER (nominal)


SCOP / SEER
MAx No. OF CONNECTABLE INDOOR UNITS
High
AIRFLOW (m3/min)
SOUND PRESSURE LEVEL (dBA)
SOUND POWER LEVEL (dBA)
WEIgHT (kg)
DIMENSIONS (mm)
Width
Depth
(1650mm without legs)
Height
ELECTRICAL SUPPLY*
PHASE*
STARTINg CURRENT (A)*
NOMINAL SYSTEM
Heating
RUNNINg CURRENT (A)* Cooling
FUSE RATINg (MCB sizes BS EN 60947-2) - (A)*
MAINS CABLE No. Cores*

PURY-P450YSJM-A1

PURY-P500YSJM-A

PURY-P550YSJM-A

PURY-P600YSJM-A

PURY-P650YSJM-A

PURY-P700YSJM-A

56.0
50.0
50.7
48.7
46.0
13.30
12.50
15.16
12.10
7.88
4.21 / 4.00
4.97 / 6.67
45
185 / 185
59.5
79.5
240 + 240
920 + 920
760
1710
380-415v, 50Hz
Three
8/8
20.5
19.3
1 x 20 / 1 x 20
4 + earth

63.0
56.0
57.0
54.8
51.5
15.10
14.85
17.21
13.74
9.36
4.17 / 3.77
5.01 / 6.40
50
185 / 185
60
80
240 + 240
920 + 920
760
1710
380-415v, 50Hz
Three
8/8
23.3
22.9
1 x 20 / 1 x 20
4 + earth

69.0
63.0
62.4
60.0
58.0
16.95
17.30
19.32
15.42
10.90
4.07 / 3.64
4.88 / 6.20
50
185 / 185
61
81
245 + 240
920 + 920
760
1710
380-415v, 50Hz
Three
8/8
26.2
26.7
1 x 25 / 1 x 20
4 + earth

76.5
69.0
69.2
66.6
63.5
19.07
19.65
21.74
17.35
12.38
4.01 / 3.51
4.80 / 6.04
50
185 / 185
62
82
245 + 245
920 + 920
760
1710
380-415v, 50Hz
Three
8/8
29.4
30.3
1 x 25 / 1 x 25
4 + earth

81.5
73.0
73.8
70.9
67.2
20.47
21.53
23.34
18.63
13.56
3.98 / 3.39
4.97 / 5.94
50
225 / 185
62.5
82.5
270 + 245
1220 + 920
760
1710
380-415v, 50Hz
Three
8/8
31.6
33.2
1 x 32 / 1 x 25
4 + earth

88.0
80.0
88.0
76.6
73.6
22.33
23.95
28.14
20.77
15.45
3.94 / 3.34
5.04 / 5.69
50
225 / 185
63
83
270 + 245
1220 + 920
760
1710
380-415v, 50Hz
Three
8/8
34.5
37.0
1 x 40 / 1 x 25
4 + earth

Note: * A separate power supply is required for each module. Where more than one figure is quoted there are multiple modules. For piping restrictions for PURY-P450-700YSJM-A(1) please see page 1.5.50

Product Dimensions

PURY-P450YSJM-A1, PURY-P500/550/600YSJM-A

Side View

Front View
920

Outdoor unit 1

30

920

Outdoor unit 2

1710

1650

760

Discharge air

Intake
air

Intake
air

Intake
air

Twinning pipe(Low pressure)


<optional parts>

(60)

Product Dimensions

Detachable leg

To BC controller
Twinning pipe(High pressure)
<optional parts>
To BC controller

PURY-P650/700YSJM-A

Side View

Front View
1220

760

Outdoor unit 1

30

920

Outdoor unit 2

1650

1710

Discharge air

Intake
air

Intake
air

Twinning pipe(Low pressure)


<optional parts>

Intake
air

(60)

Air Conditioning
1.5.41 1.121

Detachable leg

To BC controller
Twinning pipe(High pressure)
<optional parts>
To BC controller

R2 Series Standard (18-28hp) - Heat Recovery Outdoor Unit

1.5.42

R2 Series Standard
(30-36hp)
Simultaneous Heating and
Cooling with Heat Recovery
Outdoor Unit

Setting the standard in efficiency


Throughout the year, many buildings require cooling in some areas and heating in others - even in adjacent rooms. The outstanding
City Multi R2 system meets this requirement by distributing surplus heat from cooling operations (and vice versa) to rooms where it is
needed. This efficiency can result in energy savings of up to 30% over conventional systems.

Key Features
High efficiency inverter technology, with low start currents and wrap around coil for added efficiency
Up to 50 indoor units connected to each outdoor unit
Easy to install unique 2-pipe technology means minimal disruption, quicker installation and less connections than 3 pipe equivalents
Pipe run of 165m with a total system pipe length of up to 950m
100% inverter control
High Sensible Cooling Function - by raising the off coil temperature, a 10% increase in sensible cooling capacity
over standard operation is achievable, the result being greater comfort for occupants
High Performance Heating Mode for low ambient conditions
Compact chassis for easier installation

MODEL REFERENCE
CAPACITY (kW)

POWER INPUT (kW)

Heating (nominal)
Cooling (nominal)
High Performance Heating (UK)
COP Priority Heating (UK)
Cooling (UK)
Heating (nominal)
Cooling (nominal)
High Performance Heating (UK)
COP Priority Heating (UK)
Cooling (UK)

COP / EER (nominal)


SCOP / SEER
MAx No. OF CONNECTABLE INDOOR UNITS
High
AIRFLOW (m3/min)
SOUND PRESSURE LEVEL (dBA)
SOUND POWER LEVEL (dBA)
WEIgHT (kg)
DIMENSIONS (mm)
Width
Depth
(1650mm without legs)
Height
ELECTRICAL SUPPLY*
PHASE*
STARTINg CURRENT (A)*
NOMINAL SYSTEM
Heating
RUNNINg CURRENT (A)* Cooling
FUSE RATINg (MCB sizes BS EN 60947-2) - (A)*
MAINS CABLE No. Cores*

PURY-P750YSJM-A

PURY-P800YSJM-A

PURY-P850YSJM-A

PURY-P900YSJM-A

95.0
85.0
95.0
82.7
78.2
24.05
26.47
30.30
22.37
17.07
3.95 / 3.21
5.05 / 5.75
50
225 / 225
63.5
83.5
270 + 270
1220 + 1220
760
1710
380-415v, 50Hz
Three
8/8
37.1
40.9
1 x 40 / 1 x 32
4 + earth

100.0
90.0
100.0
87.0
82.8
26.04
28.30
32.81
24.22
18.25
3.84 / 3.18
5.07 / 5.66
50
225 / 225
64
84
270 + 270
1220 + 1220
760
1710
380-415v, 50Hz
Three
8/8
40.2
43.7
1 x 40 / 1 x 40
4 + earth

108.0
96.0
102.6
95.0
88.3
28.42
29.26
37.80
26.15
17.85
3.80 / 3.28
4.95 / 6.18
50
360 / 225
64.5
84.5
320 + 270
1750 + 1220
760
1710
380-415v, 50Hz
Three
8/8
43.9
45.2
1 x 40 / 1 x 40
4 + earth

113.0
101.0
107.4
99.4
92.9
30.05
30.23
39.97
27.65
18.44
3.76 / 3.34
4.99 / 6.29
50
360 / 360
65
85
320 + 320
1750 + 1750
760
1710
380-415v, 50Hz
Three
8/8
46.4
46.7
1 x 40 / 1 x 40
4 + earth

Note: * A separate power supply is required for each module. Where more than one figure is quoted there are multiple modules. For piping restrictions for PURY-P750-900YSJM-A please see page 1.5.50

Product Dimensions

PURY-P750/800YSJM-A

Side View

Front View

Side View
1220

760

Discharge air

30

Front View

760

1220

1750

Discharge air

Outdoor unit 2

Intake
air

Intake
air

Intake
air

Twinning pipe(Low pressure)


<optional parts>

Intake
air

(60)

(60)

To BC controller
Twinning pipe(High pressure)
<optional parts>
To BC controller

Detachable leg

Twinning pipe(Low pressure)


<optional parts>

Intake
air

Detachable leg

To BC controller
Twinning pipe(High pressure)
<optional parts>
To BC controller

PURY-P900YSJM-A

Side View

Front View

760

1750

Discharge air

Outdoor unit 1

30

1750

Outdoor unit 2

1650

1710

Intake
air

1220

Outdoor unit 2

Product Dimensions

30

Outdoor unit 1

1710

1650

1710

Outdoor unit 1

Intake
air

PURY-P850YSJM-A

1650

Product Dimensions

Intake
air

Intake
air

Twinning pipe(Low pressure)


<optional parts>

(60)

Detachable leg

To BC controller
Twinning pipe(High pressure)
<optional parts>
To BC controller

Air Conditioning
1.5.43 1.121

R2 Series Standard (30-36hp) - Heat Recovery Outdoor Unit

1.5.44

R2 Series
High COP
(8-20hp)
Simultaneous Heating and
Cooling with Heat Recovery
Outdoor Unit

Improved for even higher efficiency


Throughout the year, many buildings require cooling in some areas and heating in others - even in adjacent rooms. The outstanding
City Multi R2 system meets this requirement by distributing surplus heat from cooling operations (and vice versa) to rooms where it is
needed. This efficiency can result in energy savings of up to 30% over conventional systems.

Key Features
Optimised for seasonal performance providing up to 10% improvement in efficiency over YJM -EP High COP models
Automatic refrigerant temperature control function for even further efficiency and comfort, with optional external change over control signal
New and improved high efficiency inverter driven compressor with very low start currents
Up to 50 indoor units connected to each outdoor unit
Easy to install unique 2-pipe technology means minimal disruption, quicker installation and less connections than 3 pipe equivalents
Pipe run of 165m with a total system pipe length of up to 750m
100% inverter control
High Sensible Cooling Function - by raising the off coil temperature, a 10% increase in sensible cooling capacity
over standard operation is achievable, the result being greater comfort for occupants
High Performance Heating Mode for low ambient conditions

MODEL REFERENCE
CAPACITY (kW)

POWER INPUT (kW)

Heating (nominal)
Cooling (nominal)
High Performance Heating (UK)
COP Priority Heating (UK)
Cooling (UK)
Heating (nominal)
Cooling (nominal)
High Performance Heating (UK)
COP Priority Heating (UK)
Cooling (UK)

COP / EER (nominal)


SCOP / SEER
Max No. OF CONNECTABLE INDOOR UNITS
Max CONNECTABLE CAPACITY
AIRFLOW (m3/min)
High
SOUND PRESSURE LEVEL (dBA)
SOUND POWER LEVEL (dBA)
WEIgHT (kg)
DIMENSIONS (mm)
Width
Depth
(1650mm without legs)
Height
ELECTRICAL SUPPLY *
PHASE*
STARTINg CURRENT (A)*
NOMINAL SYSTEM RUNNINg CURRENT (A)* Heating / Cooling
gUARANTEED OPERATINg RANgE (C) Heating / Cooling
FUSE RATINg (MCB sizes BS EN 60947-2) - (A)*
MAINS CABLE No. Cores*

PURY-EP200YKM-A PURY-EP250YKM-A PURY-EP300YKM-A PURY-EP350YKM-A PURY-EP400YSKM-A PURY-EP450YSKM-A PURY-EP500YSKM-A


25.0
22.4
25.0
22.8
21.3
6.31
5.51
7.89
6.25
3.20
4.06 / 3.96
5.46 / 8.12
20
50~150% OU Capacity
175
57
77
232
1220
740
1710
380-415v, 50Hz
Three
8
9.7 / 8.5
-20~15.5 / -5~46
1 x 20
4

31.5
37.5
45.0
50.0
56.0
63.0
28.0
33.5
40.0
45.0
50.0
56.0
31.5
35.6
42.8
47.5
50.7
57.0
28.7
32.3
38.7
43.0
48.7
54.8
26.6
31.5
37.6
42.3
46.0
51.5
8.07
9.56
11.81
12.62
14.24
16.15
7.05
8.03
10.55
11.45
12.85
14.54
10.09
12.71
15.71
16.78
14.65
16.58
7.99
9.27
11.46
12.24
11.69
13.23
4.09
5.14
6.75
7.33
8.03
9.09
3.9 / 3.97
3.92 / 4.17
3.81 / 3.79
3.96 / 3.93
3.93 / 3.89
3.96 / 3.85
5.58 / 7.94
5.34 / 8.70
5.60 / 7.90
5.55 / 8.75
5.77 / 8.34
5.78 / 8.18
25
30
35
40
45
50
50~150% OU Capacity 50~150% OU Capacity 50~150% OU Capacity 50~150% OU Capacity 50~150% OU Capacity 50~150% OU Capacity
175
320
320
175 / 175
175 / 175
175 / 175
60
60
62
60
62
63
80
80
82
80
82
837
232
322
322
232 + 232
232 + 232
232 + 232
1220
1750
1750
1220 + 1220
1220 + 1220
1220 + 1220
740
740
740
740
740
740
1710
1710
1710
1710
1710
1710
380-415v, 50Hz
380-415v, 50Hz
380-415v, 50Hz
380-415v, 50Hz
380-415v, 50Hz
380-415v, 50Hz
Three
Three
Three
Three
Three
Three
8
8
8
8/8
8/8
8/8
12.4 / 10.8
14.7 / 12.4
18.2 / 16.3
19.5 / 17.6
22.0 / 19.8
24.9 / 22.4
-20~15.5 / -5~46
-20~15.5 / -5~46
-20~15.5 / -5~46
-20~15.5 / -5~46
-20~15.5 / -5~46
-20~15.5 / -5~46
1 x 20
1 x 25
1 x 32
1 x 20 / 1 x 20
1 x 20 / 1 x 20
1 x 20 / 1 x 20
4
4
4
4
4
4

Note: * A separate power supply is required for each module. Where more than one figure is quoted there are multiple modules. For piping restrictions for PURY-EP200-500Y(S)KM-A please see page 1.5.50

Product Dimensions

PURY-EP200/250YKM-A

70

70

150

740

600=150X4

Upper View

600=1504

Upper View

PURY-EP300/350YKM-A

740

Product Dimensions

19.5

1181
1220

49

19.5
19.5

831

831

19.5

1750

Discharge air

303

303

Discharge air

Control box

Service panel

Service
panel

Refrigerant service valve


<Low pressure>
Refrigerant service valve
<High pressure>

Fan box

Side View

Front View

Product Dimensions

20

20
586

Side View

60
57

526
541
562

75
58
140

Sling hole
Detachable leg
(front and back,3 points)
(60)

60
57

217

77

Sling hole
Detachable leg
(front and back,2 points)

89

75
58
140

145

262

54

236
251
272

57

(60)

60

( 60)

20
586

89

20

217
145

262

57

(60)

54

60

1650

Intake
air

1347

Intake
air

77

Service
panel

Intake
air

1710

1650

Refrigerant service valve


<Low pressure>
Refrigerant service valve
<High pressure>

1347

Intake
air

1710

Control box

Intake
air

Intake
air

Front View

PURY-EP400/450/500YSKM-A

Side View

Front View

740

1220

Discharge air

30

1220

Outdoor unit 2

1650

1710

Outdoor unit 1

Intake
air

Intake
air

Twinning pipe(Low pressure)


<optional parts>

Intake
air

(60)

Detachable leg

Air Conditioning
1.5.45 1.121

To BC controller
Twinning pipe(High pressure)
<optional parts>
To BC controller

R2 Series High COP (8-20hp) - Heat Recovery Outdoor Unit

1.5.46

R2 Series
High COP
(22-28hp)
Simultaneous Heating and
Cooling with Heat Recovery
Outdoor Unit

Improved for even higher efficiency


Throughout the year, many buildings require cooling in some areas and heating in others - even in adjacent rooms. The outstanding
City Multi R2 system meets this requirement by distributing surplus heat from cooling operations (and vice versa) to rooms where it is
needed. This efficiency can result in energy savings of up to 30% over conventional systems.

Key Features
Optimised for seasonal performance providing up to 10% improvement in efficiency over YJM-EP High COP models
Automatic refrigerant temperature control function for even further efficiency and comfort, with optional external change over control signal
New and improved high efficiency inverter driven compressor with very low start currents
Up to 50 indoor units connected to each outdoor unit
Easy to install unique 2-pipe technology means minimal disruption, quicker installation and less connections than 3 pipe equivalents
Pipe run of 165m with a total system pipe length of up to 800m
100% inverter control
High Sensible Cooling Function - by raising the off coil temperature, a 10% increase in sensible cooling capacity
over standard operation is achievable, the result being greater comfort for occupants
High Performance Heating Mode for low ambient conditions

MODEL REFERENCE
CAPACITY (kW)

POWER INPUT (kW)

Heating (nominal)
Cooling (nominal)
High Performance Heating (UK)
COP Priority Heating (UK)
Cooling (UK)
Heating (nominal)
Cooling (nominal)
High Performance Heating (UK)
COP Priority Heating (UK)
Cooling (UK)

COP / EER (nominal)


SCOP / SEER
Max No. OF CONNECTABLE INDOOR UNITS
Max CONNECTABLE CAPACITY
High
AIRFLOW (m3/min)
SOUND PRESSURE LEVEL (dBA)
SOUND POWER LEVEL (dBA)
WEIgHT (kg)
DIMENSIONS (mm)
Width
Depth
(1650mm without legs)
Height
ELECTRICAL SUPPLY *
PHASE*
STARTINg CURRENT (A)*
NOMINAL SYSTEM RUNNINg CURRENT (A)* Heating / Cooling
gUARANTEED OPERATINg RANgE (C) Heating / Cooling
FUSE RATINg (MCB sizes BS EN 60947-2) - (A)*
MAINS CABLE No. Cores*

PURY-EP550YSKM-A

PURY-EP600YSKM-A

PURY-EP650YSKM-A

PURY-EP700YSKM-A

69.0
63.0
62.4
60.0
58.0
17.64
15.98
18.22
14.54
9.99
3.91 / 3.94
5.59 / 8.09
50
50~150% OU Capacity
320 / 175
63
83
322 + 232
1750 + 1220
740
1710
380-415v, 50Hz
Three
8/8
27.2 / 24.7
-20~15.5 / -5~46
1 x 25 / 1 x 20
4

76.5
69.0
69.2
66.6
63.5
19.51
17.07
19.46
15.53
10.67
3.94 / 4.04
5.41 / 8.10
50
50~150% OU Capacity
320 / 320
63
83
322 + 322
1750 + 1750
740
1710
380-415v, 50Hz
Three
8/8
30.1 / 26.3
-20~15.5 / -5~46
1 x 25 / 1 x 25
4

81.5
73.0
73.8
70.9
67.2
21.16
18.91
21.56
17.21
11.82
3.85 / 3.86
5.51 / 7.88
50
50~150% OU Capacity
320 / 320
64
84
322 + 322
1750 + 1750
740
1710
380-415v, 50Hz
Three
8/8
32.7 / 29.2
-20~15.5 / -5~46
1 x 32 / 1 x 25
4

88.0
80.0
88.0
76.6
73.6
23.28
21.79
27.46
20.26
14.05
3.78 / 3.67
5.83 / 7.60
50
50~150% OU Capacity
320 / 320
65
85
322 + 322
1750 + 1750
740
1710
380-415v, 50Hz
Three
8/8
35.9 / 33.6
-20~15.5 / -5~46
1 x 32 / 1 x 32
4

Note: * A separate power supply is required for each module. Where more than one figure is quoted there are multiple modules. For piping restrictions for PURY-EP550-700YSKM-A please see pages 1.5.50

Product Dimensions

PURY-EP550YSKM-A

Side View

Front View
1750

Outdoor unit 1

30

1220

Outdoor unit 2

1650

1710

740

Discharge air

Intake
air

Intake
air

Intake
air

Twinning pipe(Low pressure)


<optional parts>

(60)

To BC controller
Twinning pipe(High pressure)
<optional parts>

Detachable leg

To BC controller

Product Dimensions

PURY-EP600/650/700YSKM-A

Side View

Front View
30

1750

Outdoor unit 2

1650

1710

1750

Outdoor unit 1

1 10

740

Discharge air

Intake
air

Intake
air

Intake
air

Twinning pipe(Low pressure)


<optional parts>

(60)

Detachable leg

To BC controller
Twinning pipe(High pressure)
<optional parts>
To BC controller

Air Conditioning
1.5.47 1.121

R2 Series High COP (22-28hp) - Heat Recovery Outdoor Unit

1.5.48

R2 Series
Replace Multi
(8-12hp)
Simultaneous Heating and
Cooling with Heat Recovery
Outdoor Unit

Enables the replacement of VRF systems, whilst utilising existing R22 / R407c pipework
The latest VRF Replace Multi from Mitsubishi Electric is specifically designed for the maturing refurbishment sector, enabling the reuse of existing
R22 / R407c pipework, whilst also allowing the upgrade to some of the most efficient systems available in the market. Replace Multi will clean
the existing pipework during commissioning, removing any deposits and R22 mineral oil that would have ordinarily meant that new pipework
would have been called for. The implications of this are significant savings on cost and time, whilst also minimising any potential disruption.

Key Features
tried and tested technology
Efficient use of existing resources - refrigerant piping, control and power wiring and less waste materials
Increased energy efficiency - up to 105% (size P200) more efficient than an old Mitsubishi Electric R22 system
Reduced installation costs of up to 55%
Reduced CO2 emissions and running cost savings of up to 45%
Reduced installation time with minimised disruption
Ability to replace many non Mitsubishi Electric systems
High Performance Heating Mode for low ambient conditions
Additional function to protect existing pipes
For more information on the Case for Replace, please visit the website: replace.mitsubishielectric.co.uk

MODEL REFERENCE
CAPACITY (kW)

POWER INPUT (kW)

Heating (nominal)
Cooling (nominal)
High Performance Heating (UK)
COP Priority Heating (UK)
Cooling (UK)
Heating (nominal)
Cooling (nominal)
High Performance Heating (UK)
COP Priority Heating (UK)
Cooling (UK)

COP / EER (nominal)


SCOP / SEER
MAx No. OF CONNECTABLE INDOOR UNITS
High
AIRFLOW (m3/min)
SOUND PRESSURE LEVEL (dBA)
SOUND POWER LEVEL (dBA)
WEIgHT (kg)
DIMENSIONS (mm)
Width
Depth
(1650mm without legs)
Height
ELECTRICAL SUPPLY*
PHASE*
STARTINg CURRENT (A)*
NOMINAL SYSTEM
Heating
RUNNINg CURRENT (A)* Cooling
FUSE RATINg (MCB sizes BS EN 60947-2) - (A)*
MAINS CABLE No. Cores*

PURY-RP200YJM-B

PURY-RP250YJM-B

PURY-RP300YJM-B

25.0
22.4
24.0
21.8
21.1
5.50
4.95
7.26
5.34
3.61
4.54 / 4.52
- / 5.75
20
225
56
76
275
1220
760
1710
380-415v, 50Hz
Three
8
8.9
8.0
1 x 20
4 + earth

31.5
28.0
30.2
27.4
26.3
7.22
6.82
9.53
7.00
4.98
4.36 / 4.10
- / 5.15
25
225
57
77
290
1220
760
1710
380-415v, 50Hz
Three
8
11.9
11.2
1 x 20
4 + earth

37.5
33.5
36.0
32.6
31.5
8.70
8.35
11.48
8.44
6.10
4.31 / 4.01
- / 4.98
30
225
59
79
290
1220
760
1710
380-415v, 50Hz
Three
8
14.6
13.6
1 x 25
4 + earth

Note: * A separate power supply is required for each module. Where more than one figure is quoted there are multiple modules.

R2 SERIES REPLACE MULtI PIPING REStRICtIONS


TOTAL PIPINg LENgTH
FURTHEST PIPINg LENgTH
LENgTH BETWEEN OU AND BC
LENgTH BETWEEN FURTHEST IU AND BC

220m max
100m max
70m max
30m max

HEIgHT BETWEEN OU AND IU (OU ABOVE IU)


HEIgHT BETWEEN OU AND IU (OU BELOW IU)
HEIgHT BETWEEN IU AND BC
HEIgHT BETWEEN IU AND IU
HEIgHT BETWEEN BC (MAIN OR SUB) AND SUB BC
Note: For detailed piping design see databook.

50m max
40m max
15m max
15m max
15m max

Product Dimensions

PURY-RP200/250/300YJM-B

760

Upper View

1220

Side View

Front View

240

Discharge air

Control box

760

Air Conditioning
1.5.49 1.121

235
251
271

58
75
140

(60)

60
55

90

217

25

25

(60)

54

60
55

146

77

Refrigerant service
valve <High pressure>

1650
1710

Service
panel

Refrigerant service
valve <Low pressure>

1410

Intake
air

Intake
air

Intake
air

Detachable leg
(front and back, 2 points)

R2 Series Replace Multi (8-12hp) - Heat Recovery Outdoor Unit

1.5.50

R2 Series Piping
Restrictions
tABLE 1: tOtAL PIPE LENGtH

GRAPH 1: tOtAL PIPING LENGtH REStRICtIONS

OUtDOOR MODEL

MAX LENGTH

P200, P250, P300, EP200

550m*1

P350, P400, P450, EP250, EP300, EP350

600m*1

P500, P550, EP400, EP450, EP500, EP550

750m*

Total Extended Pipe Length (m)

1000

P600, P650, EP600, EP650, EP700

800m*1

P700, P750, P800, P850, P900

950m*1

Note: *1 Please refer to Graph 1.

900
800
700

PURY-P700,750,800,850,900YSJM-A

600
PURY-P600,650YSJM-A, PURY-EP600,650,700YSKM-A
PURY-P500,550YSJM-A, PURY-EP400,450,500,550YSKM-A

500
400

PURY-P350,400,450Y(S)JM-A(1), PURY-EP250,300,350YKM-A

300

PURY-P200,250,300YJM-A, PURY-EP200YKM-A

200
100
0
10

20

30

40

50

60

70

80

90

100

110

Distance Between Outdoor Unit and BC Controller (m)

PIPE LENGtH

CMB-P-V-GA1/HA1 is used.

PIPE SECTION

MAX LENGTH

A+B+a+b+c+d

(See Table 1)

A+B+d

165m

110m*1

B+d

60m*2 (40m)

Height Between OU and IU (OU above IU)

50m

Height Between OU and IU (OU below IU)

40m

Height Between IU and BC

h1

15m

Height Between IU and IU

h2

15m

(1 BC CONtROLLER, NO SUB BC CONtROLLER)

Total Piping Length


Furthest Piping Length
Length Between OU and BC
Length Between Furthest IU and BC

Please Note: this does not apply to PURY-RP models

(P200-P250)

Notes: *1 Please refer to Graph 1. *2 Height difference between BC controller and furthest indoor unit is zero.

PIPE LENGtH
(>1 BC CONtROLLER FOR 1 OUtDOOR UNIt)

Total Piping Length


(CMY-Y202SS-G2
CMY-Y102LS-G2
CMY-102SS-G2)

Furthest Piping Length


Length Between OU and BC
Length Between Furthest IU and BC
Height Between OU and IU (OU above IU)

PIPE SECTION

MAX LENGTH

A+B+C+D+E+a+b+c+d+e+f

(See Table 1)

A+C+E+f

165m

110m*1

B+d or C+D+e or C+E+f

60m*2 (40m)

50m

Height Between OU and IU (OU below IU)

40m

Height Between IU and BC

h1

15m

Height Between IU and IU

h2

15m

Height Between BC (Main or Sub) and BC (Sub)

h3

15m

(P200-P250)

Notes: *1 Please refer to Graph 1. *2 Height difference between BC controller and furthest indoor unit is zero.

PIPE LENGtH
(>1 BC CONtROLLER FOR 2 OUtDOOR UNItS)

Refer to City Multi Accessories/Optional Extras section for detail.

Total Piping Length


Furthest Piping Length

(CMY-Y202SS-G2
CMY-Y102LS-G2
CMY-102SS-G2)

(P200-P250)

Please Note: this does not apply to PURY-RP models

Air Conditioning
1.5.51 1.121

Length Between OU and BC


Length Between Furthest IU and BC

PIPE SECTION

MAX LENGTH

F+g+H+A+B+C+D+E+a+b+c+d+e+f

(See Table 1)

F(g)+A+C+E+f

165m

F(g)+A

110m*1

B+d or C+D+e or C+E+f

60m*2 (40m)

Height Between OU and IU (OU above IU)

50m

Height Between OU and IU (OU below IU)

Height Between IU and BC

h1

15m

Height Between IU and IU

h2

15m

Height Between BC (Main or Sub) and BC (Sub)

h3

15m

40m

Length Between Main OU and Sub OU

F+g or H

5m

Height Between Main OU and Sub OU

h4

0.1m

Notes: *1 Please refer to Graph 1. *2 Height difference between BC controller and furthest indoor unit is zero.

R2 Series Piping Restrictions

1.5.52

WY Series
(8-24hp)
Heat Pump, Water Cooled
Condensing Unit

The WY Series has all the benefits of the Y Series using water cooled condensing units. It is also able to produce heat
recovery via the water circuit between heat source units, making for a very economical system. Like the air source versions,
the water cooled units benefit from a modular design approach. A twinning kit is required for double combinations.

Key Features
High COPs / EERs possible thanks to increased efficiency and careful control of the system, allowing the largest
operational water circuit temperature band ever
Combining WY with waste heat energy provides unique application solutions
Up to 50 indoor units can now be connected to each condensing unit
100% inverter control
Pipe run of 165m with a total system pipe length of up to 500m
High Sensible Cooling Function - by raising the off coil temperature, a 10% increase in sensible cooling capacity
over standard operation is achievable, the result being greater comfort for occupants
Able to operate with closed loop and open loop ground source water temperatures,
bore hole and slinky applications are possible
Easy maintenance - front panel access to all PCBs
Condensing units must be situated indoors

MODEL REFERENCE
CAPACITY (kW)
POWER INPUT (kW)

Heating (nominal)
Cooling (nominal)
Heating (nominal)
Cooling (nominal)

COP / EER (nominal)


SCOP / SEER
MAx No. OF CONNECTABLE INDOOR UNITS
SOUND PRESSURE LEVEL (dBA)
SOUND POWER LEVEL (dBA)
WEIgHT (kg)
DIMENSIONS (mm)
Width
Depth
(1100mm without legs)
Height
ELECTRICAL SUPPLY*
PHASE*
STARTINg CURRENT (A)*
NOMINAL SYSTEM
Heating
RUNNINg CURRENT (A)* Cooling
FUSE RATINg (BS88) - HRC (A)*
MAINS CABLE No. Cores*

PQHY-P200YHM-A PQHY-P250YHM-A PQHY-P300YHM-A PQHY-P400YSHM-A PQHY-P450YSHM-A PQHY-P500YSHM-A PQHY-P550YSHM-A PQHY-P600YSHM-A


25.0
22.4
4.12
3.92
6.06 / 5.71
5.51 / 5.63
17
47
61
195
880
550
1160
380-415v, 50Hz
Three
8
6.3
6.0
1 x 20
4 + earth

31.5
28.0
5.80
5.45
5.43 / 5.13
5.30 / 6.38
21
49
63
195
880
550
1160
380-415v, 50Hz
Three
8
8.9
8.4
1 x 20
4 + earth

37.5
33.5
8.15
7.36
4.60 / 4.55
5.14 / 5.85
26
50
64
195
880
550
1160
380-415v, 50Hz
Three
8
12.5
11.3
1 x 20
4 + earth

50.0
45.0
8.65
8.25
5.78 / 5.45
5.67 / 5.86
34
50
64
195 + 195
880 + 880
550
1160
380-415v, 50Hz
Three
8/8
13.3
12.7
1 x 20 / 1 x 20
4 + earth

56.0
50.0
10.42
9.84
5.37 / 5.08
5.31 / 5.92
39
51
65
195 + 195
880 + 880
550
1160
380-415v, 50Hz
Three
8/8
16.1
15.2
1 x 20 / 1 x 20
4 + earth

Note: * A separate power supply is required for each module. Where more than one figure is quoted there are multiple modules. Condensing unit must be installed inside a building.

PIPING REStRICtIONS

PQHY-P200-600Y(S)HM-A

TOTAL PIPINg LENgTH

300m max for sizes 200-300 / 500m max for sizes 400-600

FURTHEST PIPINg LENgTH

165m max

FURTHEST PIPINg LENgTH AFTER 1st BRANCH

40m max

BETWEEN INDOOR AND OUTDOOR UNITS - HEIgHT

50m max (40m max if outdoor installed below)

BETWEEN INDOOR AND INDOOR UNITS - HEIgHT

15m max

63.0
56.0
12.06
11.45
5.22 / 4.89
5.12 / 6.06
43
52
66
195 + 195
880 + 880
550
1160
380-415v, 50Hz
Three
8/8
18.6
17.6
1 x 20 / 1 x 20
4 + earth

69.0
63.0
14.65
13.46
4.70 / 4.68
4.67 / 5.88
47
52.5
66.5
195 + 195
880 + 880
550
1160
380-415v, 50Hz
Three
8/8
22.6
20.8
1 x 20 / 1 x 20
4 + earth

76.5
69.0
17.12
15.48
4.46 / 4.45
5.07 / 5.80
50
53
67
195 + 195
880 + 880
550
1160
380-415v, 50Hz
Three
8/8
26.4
23.9
1 x 20 / 1 x 20
4 + earth

Product Dimensions

Product Dimensions

PQHY-P200/250/300YHM-A

PQHY-P400/450/500/550/600YSHM-A

550

Upper View

880
t lb

Front View

Side View

Side View

Front View

Control box

1780
20

880

550

Heat Source unit 1

880

Heat Source unit 2

Refrigerant service
valve <Liquid>
Refrigerant service
valve <Gas>

433
548
608
563
584

Air Conditioning
1.5.53 1.121

83
58

1160
1100

60
550

(60)

20
60
Detachable leg
74
(front and back, 2 points)

78
168

(60)

18

141
213
240

121 226
234

1100
1160

Service
panel

Detachable leg
(front and back, 2 points)

To indoor unit
Liquid Twinning pipe <optional parts>
To indoor unit
Gas Twinning pipe <optional parts>

75
140

WY Series (8-24hp) - Heat Pump Outdoor Unit

1.5.54

WY Series
(26-36hp)
Heat Pump, Water Cooled
Condensing Unit

The WY Series has all the benefits of the Y Series using water cooled condensing units. It is also able to produce heat
recovery via the water circuit between heat source units, making for a very economical system. Like the air source versions,
the water cooled units benefit from a modular design approach. A twinning kit is required.

Key Features
High COPs / EERs possible thanks to increased efficiency and careful control of the system, allowing the largest
operational water circuit temperature band ever
Combining WY with waste heat energy provides unique application solutions
Up to 50 indoor units can now be connected to each condensing unit
100% inverter control
Pipe run of 165m with a total system pipe length of up to 500m
High Sensible Cooling Function - by raising the off coil temperature, a 10% increase in sensible cooling capacity
over standard operation is achievable, the result being greater comfort for occupants
Able to operate with closed loop and open loop ground source water temperatures,
bore hole and slinky applications are possible
Easy maintenance - front panel access to all PCBs
Condensing units must be situated indoors

MODEL REFERENCE
CAPACITY (kW)
POWER INPUT (kW)

Heating (nominal)
Cooling (nominal)
Heating (nominal)
Cooling (nominal)

COP / EER (nominal)


SCOP / SEER
MAx No. OF CONNECTABLE INDOOR UNITS
SOUND PRESSURE LEVEL (dBA)
SOUND POWER LEVEL (dBA)
WEIgHT (kg)
DIMENSIONS (mm)
Width
Depth
(1100mm without legs)
Height
ELECTRICAL SUPPLY*
PHASE*
STARTINg CURRENT (A)*
NOMINAL SYSTEM
Heating
RUNNINg CURRENT (A)* Cooling
FUSE RATINg (BS88) - HRC (A)*
MAINS CABLE No. Cores*

PQHY-P650YSHM-A

PQHY-P700YSHM-A

PQHY-P750YSHM-A

PQHY-P800YSHM-A

PQHY-P850YSHM-A

PQHY-P900YSHM-A

81.5
73.0
14.74
13.96
5.52 / 5.22
4.95 / 5.95
50
53
67
195 + 195 + 195
880 + 880 + 880
550
1160
380-415v, 50Hz
Three
8/8/8
22.7
21.5
1 x 20 / 1 x 20 / 1 x 20
4 + earth

88.0
80.0
16.51
15.58
5.33 / 5.13
4.98 / 6.23
50
53.5
67.5
195 + 195 + 195
880 + 880 + 880
550
1160
380-415v, 50Hz
Three
8/8/8
25.5
24.0
1 x 20 / 1 x 20 / 1 x 20
4 + earth

95.0
85.0
18.27
17.19
5.19 / 4.94
5.03 / 6.15
50
54
68
195 + 195 + 195
880 + 880 + 880
550
1160
380-415v, 50Hz
Three
8/8/8
28.2
26.5
1 x 20 / 1 x 20 / 1 x 20
4 + earth

100.0
90.0
20.74
19.18
4.82 / 4.69
4.85 / 5.89
50
54
68
195 + 195 + 195
880 + 880 + 880
550
1160
380-415v, 50Hz
Three
8/8/8
32.0
29.6
1 x 20 / 1 x 20 / 1 x 20
4 + earth

108.0
96.0
23.21
21.20
4.65 / 4.52
4.89 / 5.68
50
54.5
68.5
195 + 195 + 195
880 + 880 + 880
550
1160
380-415v, 50Hz
Three
8/8/8
35.8
32.7
1 x 20 / 1 x 20 / 1 x 20
4 + earth

113.0
101.0
25.67
23.22
4.40 / 4.34
4.72 / 5.37
50
55
69
195 + 195 + 195
880 + 880 + 880
550
1160
380-415v, 50Hz
Three
8/8/8
39.6
35.8
1 x 20 / 1 x 20 / 1 x 20
4 + earth

Note: * A separate power supply is required for each module. Where more than one figure is quoted there are multiple modules. Condensing unit must be installed inside a building.

PIPING REStRICtIONS

PQHY-P650-900YSHM-A

TOTAL PIPINg LENgTH

500m

FURTHEST PIPINg LENgTH

165m max

FURTHEST PIPINg LENgTH AFTER 1st BRANCH

40m max

BETWEEN INDOOR AND OUTDOOR UNITS - HEIgHT

50m max (40m max if outdoor installed below)

BETWEEN INDOOR AND INDOOR UNITS - HEIgHT

15m max

Product Dimensions

PQHY-P650/700/750/800/900YSHM-A

Side View

Front View

550

2680
880

880

880

Heat Source unit 1

1100

Heat Source unit 2

20

(60)

1160

Heat Source unit 3

20

To indoor unit
Detachable leg
(front and back,2 points)

Liquid Twinning pipe 1 <optional parts>

Liquid Twinning pipe 2 <optional parts>

Gas Twinning pipe 1 <optional parts>

Gas Twinning pipe 2 <optional parts>

To indoor unit

Air Conditioning
1.5.55 1.121

WY Series (26-36hp) - Heat Pump Outdoor Unit

1.5.56

WR2 Series
(8-24hp)
Water Cooled Condensing
Unit Simultaneous Heating
and Cooling with Double
Heat Recovery

The WR2 system has double heat recovery potential, making this system very economical. Not only does it produce heat recovery from
indoor units on the same refrigerant circuit, it also produces heat recovery via the water circuit between heat source units. Like the air
source versions, the water cooled units benefit from a modular design approach. A twinning kit is required for double combinations.

Key Features
All the benefits of the R2 Series with water cooled condensing units, using 100% inverter control
High COPs / EERs possible thanks to increased efficiency and careful control of the system, allowing the largest
operational water circuit temperature band ever
Unique 2-pipe refrigerant circuit allows simultaneous heating and cooling plus heat recovery between up to 50 indoor units as with the R2 system
total building heat recovery made possible by exchanging energy in both refrigerant and water circuits
Combining WR2 with waste heat energy provides unique application solutions
Pipe run of 165m with a total system pipe length of up to 750m
High Sensible Cooling Function - by raising the off coil temperature, a 10% increase in sensible cooling capacity
over standard operation is achievable, the result being greater comfort for occupants
Able to operate with closed loop and open loop ground source water temperatures, bore hole and slinky applications are possible
Easy maintenance - front panel access to all PCBs
Condensing units must be situated indoors

MODEL REFERENCE
CAPACITY (kW)
POWER INPUT (kW)

Heating (nominal)
Cooling (nominal)
Heating (nominal)
Cooling (nominal)

COP / EER (nominal)


SCOP / SEER
MAx No. OF CONNECTABLE INDOOR UNITS
SOUND PRESSURE LEVEL (dBA)
SOUND POWER LEVEL (dBA)
WEIgHT (kg)
DIMENSIONS (mm)
Width
Depth
(1100mm without legs)
Height
ELECTRICAL SUPPLY*
PHASE*
STARTINg CURRENT (A)*
NOMINAL SYSTEM
Heating
RUNNINg CURRENT (A)* Cooling
FUSE RATINg (BS88) - HRC (A)*
MAINS CABLE No. Cores*

PQRY-P200YHM-A PQRY-P250YHM-A PQRY-P300YHM-A PQRY-P400YSHM-A PQRY-P450YSHM-A PQRY-P500YSHM-A PQRY-P550YSHM-A PQRY-P600YSHM-A


25.0
22.4
4.12
3.96
6.06 / 5.65
5.90 / 6.02
20
47
61
181
880
550
1160
380-415v, 50Hz
Three
8
6.3
6.1
1 x 20
4 + earth

31.5
28.0
5.80
5.51
5.43 / 5.08
5.36 / 6.37
25
49
63
181
880
550
1160
380-415v, 50Hz
Three
8
8.9
8.5
1 x 20
4 + earth

37.5
33.5
8.15
7.44
4.60 / 4.50
5.11 / 5.73
30
50
64
181
880
550
1160
380-415v, 50Hz
Three
8
12.5
11.5
1 x 20
4 + earth

50.0
45.0
8.65
8.32
5.78 / 5.40
5.67 / 5.75
40
50
64
181 + 181
880 + 880
550
1160
380-415v, 50Hz
Three
8/8
13.3
12.8
1 x 20 / 1 x 20
4 + earth

56.0
50.0
10.42
9.94
5.37 / 5.03
5.27 / 5.80
45
51
65
181 + 181
880 + 880
550
1160
380-415v, 50Hz
Three
8/8
16.1
15.3
1 x 20 / 1 x 20
4 + earth

63.0
56.0
12.06
11.57
5.22 / 4.84
5.11 / 6.10
50
52
66
181 + 181
880 + 880
550
1160
380-415v, 50Hz
Three
8/8
18.6
17.8
1 x 20 / 1 x 20
4 + earth

69.0
63.0
14.65
13.60
4.70 / 4.63
4.66 / 5.93
50
52.5
66.5
181 + 181
880 + 880
550
1160
380-415v, 50Hz
Three
8/8
22.6
21.0
1 x 20 / 1 x 20
4 + earth

Note: * A separate power supply is required for each module. Where more than one figure is quoted there are multiple modules. Condensing unit must be installed inside a building.

PIPING REStRICtIONS
TOTAL PIPINg LENgTH
FURTHEST PIPINg LENgTH
BETWEEN CONDENSINg UNIT AND BC CONTROLLER (MASTER) - LENgTH
BETWEEN INDOOR AND BC CONTROLLER (MASTER/SLAVE) - LENgTH
BETWEEN INDOOR AND CONDENSINg UNIT - HEIgHT
BETWEEN INDOOR AND INDOOR - HEIgHT
BETWEEN INDOOR AND BC CONTROLLER (MASTER/SLAVE) - HEIgHT
BETWEEN BC CONTROLLER (MASTER) AND BC CONTROLLER (SLAVE) - HEIgHT

PQRY-P200-600Y(S)HM-A
550m max*3 (300m) for sizes 200-300 / 750m max*3 (500m) for sizes 400-600
165m max
110m max*4
60m max*5 (40m)
50m max (40m*1)
15m max (10m*2)
15m max (10m*2)
15m max (10m*6)

Notes: *1 When condensing unit is below indoor. *2 In case of P200, P250 indoor unit. *3 Distance between condensing unit and BC Controller is 10m or less. *4 Total piping length is 300m or less (500m for sizes 400-600).
*5 Height difference between the Master BC Controller and furthest indoor unit is 0m and no size P200 or P250 indoor unit is used. *6 When using 2 sub BC Controllers, the height between them should be considered.

76.5
69.0
17.12
15.62
4.46 / 4.41
5.00 / 5.68
50
53
67
181 + 181
880 + 880
550
1160
380-415v, 50Hz
Three
8/8
26.4
24.1
1 x 20 / 1 x 20
4 + earth

Product Dimensions

Product Dimensions

PQRY-P200/250/300YHM-A

PQRY-P400/450/500/550/600YSHM-A

550

Upper View

880

Front View

Side View

Side View

Front View
1780
20

880

550

Control box

Heat Source unit 1

Heat Source unit 2

Twinning pipe
(Low pressure)
<optional parts>

60

20
60
Detachable leg
74
(front and back, 2 points)

78
168

(60)

18

121

141
213
240

226
234

1100
1160

Service
panel

1160
1100

Refrigerant service
valve <High pressure>
Refrigerant service
valve <Low pressure>

880

433
548
608
563
584

Air Conditioning
1.5.57 1.121

83
58

60
550

Detachable leg
(front and back, 2 points)

To BC controller
Twinning pipe (High pressure)
<optional parts>
To BC controller

75
140

WR2 Series (8-24hp) - Heat Recovery Outdoor Unit

1.5.58

PFD-P-VM-E
(10/20hp)
Close Control System

Mitsubishi Electrics Close Control System is specifically designed for computer rooms, laboratories etc, where a need for high sensible
cooling and close control of temperature and humidity is required. Because of the need for close control 24 hours a day, 365 days a
year, an inverter driven compressor has been incorporated into the outdoor unit, maximising the energy efficiency of the PFD series.
It can also be connected to a computer network using our Ag150 controller, in order to monitor and provide remote email alarms.

Key Features
High sensible cooling
Inverter driven capacity control
Energy efficient with high EERs
Close control of temperature, 1C
Easy to install - no service space needed at the rear of the unit
Optional soft start inverter kit on request
Quick recovery following power failure
Return or discharge air temperature control
Back-up & Rotate function available
Connectable to PUHY-P250YJM-A and PQHY-P250YHM-A
Stands now available on request

MODEL REFERENCE

PFD-P250VM-E

PFD-P500VM-E*1

CAPACITY (kW)
Cooling (nominal)
SHF
(nominal)
POWER INPUT (kW)
Cooling (nominal)
3
High
AIRFLOW (m /min)
ExTERNAL STATIC PRESSURE (Pa)
PIPE SIZE mm (in)
Gas
Liquid
SOUND PRESSURE LEVEL (dBA)
WEIgHT (kg)
DIMENSIONS (mm)
Width
Depth
Height
ELECTRICAL SUPPLY
PHASE
STARTINg CURRENT (A)
RUNNINg CURRENT (A)
Cooling
FUSE RATINg (BS88) - HRC (A)
MAINS CABLE No. Cores

28.0
0.93
2.5
160
120
22.2 (7/8)
9.52 (3/8)
59
380
1380
780
1950
380-415v, 50Hz
3
47
4.9
16
4 + earth

56.0
0.93
5.0
320
120
22.2 (7/8)*2
9.52 (3/8)*2
63
520
1980
780
1950
380-415v, 50Hz
3
68
8.7
20
4 + earth

PIPING REStRICtIONS

PFD-P-VM-E

TOTAL PIPINg LENgTH

165m max

BETWEEN INDOOR AND OUTDOOR UNITS - HEIgHT

50m max (40m max if outdoor installed below)

Notes: *1 2 x PUHY-P250YJM-A units are needed when connected to a PFD-P500VM-E. 2 x PQHY-P250YHM-A units are needed when connected to a PFD-P500VM-E. *2 PFD-P500VM-E uses two refrigerant circuits. Pipe sizes are per single refrigerant circuit.

Product Dimensions

Product Dimensions

PFD -P250V M - E

Front View

Side View

P F D -P 5 0 0 V M-E

Front View

Side View
Air inlet

1950

1950

Air inlet

220
320
680
710

Panel

Panel

Air outlet

Control box
100

1380

50

68

260

Hole for gas pipe connecting(42)


Hole for liquid pipe connecting(24)

140

140

220
320

Refrig. piping <gas> 22.2 braze

Air outlet
1980

Control box

100

50 68
780

124
68 68

Refrig. piping <gas> in 2 refrig. circuit system


type P450: 19.05 braze,
type P560: 22.2 braze No.2
Refrig. piping <liquid> in 2 refrig. circuit
system 9.52 braze No.2

Refrig. piping <gas> in 2 refrig. circuit system


type P450: 19.05 braze, type P560: 22.2 braze No.1

780

Hole for the power supply < 32 knook out hole>


Hole for the power supply <32 knock out hole>
Hole for the control wiring <32 knock out hole>
Refrig. piping <liquid> 9.52 braze

Accessories

Refrig. piping <liquid> 15.88 braze


Refrig. piping <liquid> in 2 refrig. circuit system 9.52 braze No.1

PFD Stands

Stand for PFD-P250VM-E

KS6-250

Stand for PFD-P500VM-E

KS6-500

Air Conditioning
1.5.59 1.121

Refrig. piping <gas> 28.58 braze

Hole for the control wiring < 32 knook out hole>

PFD-P-VM-E (10/20hp)

1.5.60

PLFY-P-VBM-E

Power cassettes offer 72 different airflow patterns, with the ability to handle a multitude of ceiling applications up to 4.2 metres in
height. The easy to install, slim unit is ideal for maintaining constant temperatures, thanks to adjustable vanes that allow users to
precisely direct air where its needed.

4-Way Blow Ceiling


Cassette Indoor Unit

The Mitsubishi Electric airflow control mechanism uses wider vanes so that the unit reduces drafts and smudging, whilst a high
performance drain pump on the drain lift mechanism allows drain water to be lifted up to 850mm from the ceiling surface.

Key Features
Handy corner pocket design simplifies maintenance
Airflow controllable for ceiling heights up to 4.2m, with automatic adjustment of fan speed
Reduced draft air distribution, with independent vane control
Drain pump as standard, 850mm from drain pan
Filter lowering operation down to 4m (optional PLP-6BAJ grille required)
Optional i-see Sensor for energy saving and smooth temperature control throughout the room

MODEL REFERENCE
Heating (nominal)
Cooling (nominal)
High Performance Heating (UK)
COP Priority Heating (UK)
Cooling (UK)
Hi-Sensible Mode Cooling (UK)
SHF
(UK)
Hi-Sens Mode (UK)
POWER INPUT (kW) Heating (nominal)
Cooling (nominal)
Lo-Mi1-Mi2-Hi
AIRFLOW (m3/min)
SOUND PRESSURE LEVEL (dBA) Lo-Mi1-Mi2-Hi
WEIgHT (kg)
(Grille)
DIMENSIONS (mm)Width (Grille)
Depth (Grille)
Height (Grille)
ELECTRICAL SUPPLY
PHASE
RUNNINg CURRENT (A)
Heating
Cooling
FUSE RATINg (BS88) - HRC (A)
MAINS CABLE No. Cores
gRILLE MODEL REFERENCE
CAPACITY (kW)

PLFY-P32VBM-E

PLFY-P40VBM-E

PLFY-P50VBM-E

PLFY-P63VBM-E

PLFY-P80VBM-E

PLFY-P100VBM-E

PLFY-P125VBM-E

4.0
3.6
4.0
3.7
3.4
2.6
0.82
0.96
0.02
0.03
11-12-13-14
27-28-29-31
22(6)
840 (950)
840 (950)
258 (35)
220-240v, 50Hz
Single
0.14
0.22
6
3
PLP-6BA

5.0
4.5
5.0
4.7
4.3
3.3
0.79
0.91
0.03
0.04
12-13-14-16
27-28-30-31
22(6)
840 (950)
840 (950)
258 (35)
220-240v, 50Hz
Single
0.22
0.29
6
3
PLP-6BA

6.3
5.6
6.3
5.9
5.3
4.1
0.75
0.83
0.03
0.04
12-13-14-16
27-28-30-31
22(6)
840 (950)
840 (950)
258 (35)
220-240v, 50Hz
Single
0.22
0.29
6
3
PLP-6BA

8.0
7.1
8.0
7.5
6.7
5.2
0.73
0.79
0.04
0.05
14-15-16-18
28-29-30-32
23(6)
840 (950)
840 (950)
258 (35)
220-240v, 50Hz
Single
0.29
0.36
6
3
PLP-6BA

10.0
9.0
10.0
9.4
8.5
6.5
0.72
0.78
0.06
0.07
16-18-20-22
30-32-35-37
23(6)
840 (950)
840 (950)
258 (35)
220-240v, 50Hz
Single
0.43
0.51
6
3
PLP-6BA

12.5
11.2
12.5
11.7
10.6
8.1
0.72
0.79
0.14
0.15
21-24-27-29
34-37-39-41
27(6)
840 (950)
840 (950)
298 (35)
220-240v, 50Hz
Single
0.94
1.00
6
3
PLP-6BA

16.0
14.0
16.0
15.0
13.3
10.2
0.70
0.75
0.15
0.16
22-25-28-30
35-38-41-43
27(6)
840 (950)
840 (950)
298 (35)
220-240v, 50Hz
Single
1.00
1.07
6
3
PLP-6BA

Product Dimensions

PLFY-P32/40/50/63/80/100/125VBM-E

Upper View

Lower View

Ceiling hole
20~45

860~910

20~45

Fresh air
intake hole

20~45

810

Suspension bolt pitch

597

Air intake hole

597

Air intake hole

500

Air outlet hole

Branch duct hole

950

860~910

Ceiling hole

840

For MA-Remote controller


terminal block

620

Power supply
terminal block

Branch duct hole

605

Suspension bolt pitch

Transmission terminal block

+35
-5

160

(7.5)

160

83

160

500

36

20~45

187.5

(7.5)

24

160

90

150

Air intake
grille

83

36

Air outlet hole

840

950

Side View

60

284

Drain pipe
PVC pipe: O.D. 32 (1-1/4")

377

Air Conditioning
1.5.61 1.121

190

PLFY-P32-80VBM-E

241

258

PLFY-P100-125VBM-E

281

298

35

*
+5
0

MODELS

17

156

105

50~70

140

170

A B

PLFY-P-VBM-E

1.5.62

PLFY-P-VCM-E
600x600 4-Way Blow Ceiling
Cassette Indoor Unit

The compact size of this unit is ideal for 600x600mm ceilings and with a depth of 208mm,
this lightweight unit makes installation a breeze.
This unit also comes complete with a long life filter that will last for approximately 2,500 hours.

Key Features
Compact size for handy installation and easy maintenance
Only 208mm high
Fresh air duct facility
Fits inside a standard ceiling grid

MODEL REFERENCE
Heating (nominal)
Cooling (nominal)
High Performance Heating (UK)
COP Priority Heating (UK)
Cooling (UK)
Hi-Sensible Mode Cooling (UK)
SHF
(UK)
Hi-Sens Mode (UK)
POWER INPUT (kW) Heating (nominal)
Cooling (nominal)
AIRFLOW (m3/min)
Lo-Mi-Hi
SOUND PRESSURE LEVEL (dBA) Lo-Mi-Hi
WEIgHT (kg)
(Grille)
DIMENSIONS (mm) Width (Grille)
Depth (Grille)
Height (Grille)
ELECTRICAL SUPPLY
PHASE
RUNNINg CURRENT (A)
Heating
Cooling
FUSE RATINg (BS88) - HRC (A)
MAINS CABLE No. Cores
gRILLE MODEL REFERENCE
CAPACITY (kW)

PLFY-P20VCM-E

PLFY-P25VCM-E

PLFY-P32VCM-E

PLFY-P40VCM-E

2.5
2.2
2.5
2.3
2.1
1.6
0.86
1.00
0.05
0.05
8-9-10
28-31-35
15.5(3)
570 (650)
570 (650)
235 (20)
220-240v, 50Hz
Single
0.23
0.23
6
3
SLP-2AAW

3.2
2.8
3.2
3.0
2.7
2.0
0.78
0.95
0.05
0.05
8-9-10
28-31-37
15.5(3)
570 (650)
570 (650)
235 (20)
220-240v, 50Hz
Single
0.23
0.23
6
3
SLP-2AAW

4.0
3.6
4.0
3.7
3.4
2.6
0.76
0.85
0.06
0.06
8-9-11
29-33-38
17(3)
570 (650)
570 (650)
235 (20)
220-240v, 50Hz
Single
0.28
0.28
6
3
SLP-2AAW

5.0
4.5
5.0
4.7
4.3
3.3
0.70
0.76
0.06
0.06
8-9-11
30-34-39
17(3)
570 (650)
570 (650)
235 (20)
220-240v, 50Hz
Single
0.28
0.28
6
3
SLP-2AAW

Product Dimensions

PLFY-P20/25/32/40VCM-E

Upper View

Lower View

650
301
55 35

Fresh air intake


Ceiling hole

377

Air intake hole

301

Air outlet hole

650

570

335
570

31

420

576~620

530

Suspension bolt pitch

Suspension bolt pitch

15~37

Air outlet hole

35 55

56

57

15~37

87

Air intake grille

199
352
335
576~620 Ceiling hole

15~37

377

Air intake hole


15~37

Side View

230

208

193

Air Conditioning
1.5.63 1.121

20

27

+5

93
38~58

121

235

202

66

17

PLFY-P-VCM-E

1.5.64

PMFY-P-VBM-E

Utilising a compact and lightweight body, the unit is perfect for applications where ceiling space is limited.
A total body weight of 14kg makes it one of the lightest available, fan technology also makes it one of the quietest.

1-Way Blow Ceiling


Cassette Indoor Unit

Key Features
Compact size for handy installation and easy maintenance
Airflow control technology reduces noise levels to only 27dBA (size P20)
Drain lift pump mechanism allows the drain to be positioned anywhere up to 600mm from the ceilings surface
Only 230mm height
Fresh air duct facility
Pure white grille

MODEL REFERENCE
Heating (nominal)
Cooling (nominal)
High Performance Heating (UK)
COP Priority Heating (UK)
Cooling (UK)
Hi-Sensible Mode Cooling (UK)
SHF
(UK)
Hi-Sens Mode (UK)
POWER INPUT (kW) Heating (nominal)
Cooling (nominal)
Lo-Mi1-Mi2-Hi
AIRFLOW (m3/min)
SOUND PRESSURE LEVEL (dBA) Lo-Mi1-Mi2-Hi
WEIgHT (kg)
(Grille)
DIMENSIONS (mm) Width (Grille)
Depth (Grille)
Height (Grille)
ELECTRICAL SUPPLY
PHASE
RUNNINg CURRENT (A)
Heating
Cooling
FUSE RATINg (BS88) - HRC (A)
MAINS CABLE No. Cores
gRILLE MODEL REFERENCE
CAPACITY (kW)

PMFY-P20VBM-E

PMFY-P25VBM-E

PMFY-P32VBM-E

PMFY-P40VBM-E

2.5
2.2
2.5
2.3
2.1
1.6
0.86
1.00
0.042
0.042
6.5-7.2-8.0-8.7
27-30-33-35
14(3)
812 (1000)
395 (470)
230 (30)
220-240v, 50Hz
Single
0.20
0.20
6
3
PMP-40BMW

3.2
2.8
3.2
3.0
2.7
2.0
0.81
0.95
0.044
0.044
7.3-8.0-8.6-9.3
32-34-36-37
14(3)
812 (1000)
395 (470)
230 (30)
220-240v, 50Hz
Single
0.21
0.21
6
3
PMP-40BMW

4.0
3.6
4.0
3.7
3.4
2.6
0.76
0.85
0.044
0.044
7.3-8.0-8.6-9.3
32-34-36-37
14(3)
812 (1000)
395 (470)
230 (30)
220-240v, 50Hz
Single
0.21
0.21
6
3
PMP-40BMW

5.0
4.5
5.0
4.7
4.3
3.3
0.72
0.82
0.054
0.054
7.7-8.7-9.7-10.7
33-35-37-39
14(3)
812 (1000)
395 (470)
230 (30)
220-240v, 50Hz
Single
0.26
0.26
6
3
PMP-40BMW

Product Dimensions

PMFY-P20/25/32/40VBM-E

Upper View
1000 outer side of grille
960 ceiling opening
811 suspension bolt pitch
759
20

20

20
74.5
26
20

17.5

28

45

53
247

46

69

28

45

17.5

43

20

ceiling opening

suspension bolt pitch


340

outer side of grille


470

430

20

74.5
26

Side View

Side View

Front View

395
302
254

812

141

759

230

198
(10)

50

(20)

96

176

Electrical box

( 56)
Drain pan

(96)

Lower View

470

outer side of grille

200

60

600

40

1000 outer side of grille


200

Air Conditioning
1.5.65 1.121

30

PMFY-P-VBM-E

1.5.66

PEFY-P-VMS1-E

The ultra thin ceiling concealed ducted indoor unit offers increased flexibility and is particularly suitable for places
where low noise operation is desired from a slimline body.

Ultra Thin Ceiling Concealed


Ducted Indoor Unit

Key Features
Ultra thin body - height of only 200mm & width of only 790mm (size P15-32)
Extremely quiet operation - as low as 22dBA (size P15-20)
Static pressure of 5-50Pa
Available in a size P15, ideal for hotel rooms

MODEL REFERENCE
Heating (nominal)
Cooling (nominal)
High Performance Heating (UK)
COP Priority Heating (UK)
Cooling (UK)
Hi-Sensible Mode Cooling (UK)
SHF
(UK)
Hi-Sens Mode (UK)
POWER INPUT (kW) Heating (nominal)
Cooling (nominal)
Lo-Mi-Hi
AIRFLOW (m3/min)
ExTERNAL STATIC PRESSURE (Pa)
SOUND PRESSURE LEVEL (dBA) Lo-Mi-Hi
WEIgHT (kg)
DIMENSIONS (mm) Width
Depth
Height
ELECTRICAL SUPPLY
PHASE
RUNNINg CURRENT (A)
Heating
Cooling
FUSE RATINg (BS88) - HRC (A)
MAINS CABLE No. Cores
CAPACITY (kW)

PEFY-P15VMS1-E

PEFY-P20VMS1-E

PEFY-P25VMS1-E

PEFY-P32VMS1-E

PEFY-P40VMS1-E

PEFY-P50VMS1-E

PEFY-P63VMS1-E

1.9
1.7
1.9
1.8
1.6
1.2
0.94
1.00
0.03
0.05
5.0-6.0-7.0
5-15-35-50
22-24-28
19
790
700
200
220-240v, 50Hz
Single
0.31
0.42
6
3

2.5
2.2
2.5
2.3
2.1
1.6
0.86
1.00
0.03
0.05
5.5-6.5-8.0
5-15-35-50
22-25-29
19
790
700
200
220-240v, 50Hz
Single
0.36
0.47
6
3

3.2
2.8
3.2
3.0
2.7
2.0
0.78
0.90
0.04
0.06
5.5-7.0-9.0
5-15-35-50
24-26-30
19
790
700
200
220-240v, 50Hz
Single
0.39
0.50
6
3

4.0
3.6
4.0
3.7
3.4
2.6
0.76
0.85
0.05
0.07
6.0-8.0-10.0
5-15-35-50
24-27-32
20
790
700
200
220-240v, 50Hz
Single
0.39
0.50
6
3

5.0
4.5
5.0
4.7
4.3
3.3
0.72
0.82
0.05
0.07
8.0-9.5-11.0
5-15-35-50
28-30-33
24
990
700
200
220-240v, 50Hz
Single
0.45
0.56
6
3

6.3
5.6
6.3
5.9
5.3
4.1
0.72
0.78
0.07
0.09
9.5-11.0-13.0
5-15-35-50
30-32-35
24
990
700
200
220-240v, 50Hz
Single
0.56
0.67
6
3

8.0
7.1
8.0
7.5
6.7
5.2
0.73
0.79
0.07
0.09
12.0-14.0-16.5
5-15-35-50
30-33-36
28
1190
700
200
220-240v, 50Hz
Single
0.61
0.72
6
3

Product Dimensions

PEFY-P15/20/25/32/40/50/63VMS1-E

Upper View
20
30
100

D (Duct)
100X(E-1)=F
100

10

Front View
20
12

Air
outlet

88

88
100

12 20

49

37
100 157.5

37

625 (Suspension bolt pitch)

Side View
700
677

23
270

90

200

Air
inlet

102

170

150 (Duct)
100

48

23
25

10

A
23

B (Suspension bolt pitch)


C

Air Conditioning
1.5.67 1.121

116

70
270

Model

PEFY-P15-32VMS1-E

700

752

798

660

600

PEFY-P40-50VMS1-E

900

952

998

860

800

PEFY-P63VMS1-E

1100

1152

1198

1060

11

1000

PEFY-P-VMS1-E

1.5.68

PEFY-P-VMA-E

The PEFY-P-VMA-E ducted indoor unit is concealed within the ceiling space to allow unobtrusive air conditioning.
Flexibility of duct layout allows air flow patterns to be arranged to suit any application.

Ceiling Concealed
Ducted Indoor Unit

Key Features
Low height - only 250mm
Wide range of external static pressure settings across entire range (35-150Pa)
Low noise levels thanks to the use of a centrifugal fan - as low as 23dBA (size 20-40)
Drain pump included as standard
CN105 connector available - connect to A1M for simple BEMS interfacing

MODEL REFERENCE
Heating (nominal)
Cooling (nominal)
High Performance Heating (UK)
COP Priority Heating (UK)
Cooling (UK)
Hi-Sensible Mode Cooling (UK)
SHF
(UK)
Hi-Sens Mode (UK)
POWER INPUT (kW) Heating (nominal)
Cooling (nominal)
AIRFLOW (m3/min)
Lo-Mi-Hi
ExTERNAL STATIC PRESSURE (Pa)
SOUND PRESSURE LEVEL (dBA) (50Pa) Lo-Mi-Hi
WEIgHT (kg)
DIMENSIONS (mm) Width
Depth
Height
ELECTRICAL SUPPLY
PHASE
RUNNINg CURRENT (A)
Heating
Cooling
FUSE RATINg (BS88) - HRC (A)
MAINS CABLE No. Cores
CAPACITY (kW)

PEFYP20VMA-E

PEFYP25VMA-E

PEFYP32VMA-E

PEFYP40VMA-E

PEFYP50VMA-E

PEFYP63VMA-E

PEFYP80VMA-E

PEFYP100VMA-E

PEFYP125VMA-E

3.2
4.0
5.0
6.3
10.0
12.5
16.0
8.0
2.5
2.8
3.6
4.5
5.6
9.0
11.2
14.0
7.1
2.2
3.2
4.0
5.0
6.3
10.0
12.5
16.0
8.0
2.5
3.0
3.7
4.7
5.9
9.4
11.7
15.0
7.5
2.3
2.7
3.4
4.3
5.3
8.5
10.6
13.3
6.7
2.1
2.0
2.6
3.3
4.1
6.5
8.1
10.2
5.2
1.6
0.78
0.74
0.79
0.79
0.72
0.79
0.77
0.78
0.90
0.90
0.85
0.91
0.88
0.78
0.89
0.86
0.87
1.00
0.04
0.05
0.07
0.09
0.12
0.22
0.32
0.10
0.04
0.06
0.07
0.09
0.11
0.14
0.24
0.34
0.12
0.06
6.0-7.5-8.5
7.5-9.0-10.5
10-12-14
12.0-14.5-17.0 13.5-16.0-19.0 14.5-18.0-21.0
23-28-33
28-34-40
6.0-7.5-8.5
35-50-70-100-150 35-50-70-100-150 35-50-70-100-150 35-50-70-100-150 35-50-70-100-150 35-50-70-100-150 35-50-70-100-150 35-50-70-100-150 35-50-70-100-150
25-29-32
23-25-26
23-25-26
23-26-29
23-27-30
25-29-33
26-29-34
28-33-37
32-36-40
26
23
23
23
26
32
32
42
42
900
700
700
700
900
1100
1100
1400
1400
732
732
732
732
732
732
732
732
732
250
250
250
250
250
250
250
250
250
220-240v, 50Hz 220-240v, 50Hz 220-240v, 50Hz 220-240v, 50Hz 220-240v, 50Hz 220-240v, 50Hz 220-240v, 50Hz 220-240v, 50Hz 220-240v, 50Hz
Single
Single
Single
Single
Single
Single
Single
Single
Single
0.63
0.42
0.42
0.44
0.53
0.90
1.04
1.36
1.94
0.74
0.53
0.53
0.55
0.64
1.01
1.15
1.47
2.05
6
6
6
6
6
6
6
6
6
3
3
3
3
3
3
3
3
3

Product Dimensions

PEFY-P20/25/32/40/50/63/80/100/125VMA-E

Upper View

100
30
73

20

D (Duct)
100 x (E - 1) = F
100

10

Front View

Air
outlet

21

G
18

57

210
643 (Suspension bolt pitch)

Side View
732
700

B (Suspension bolt pitch)


C

Drain pump

33

250

217

122

Drain pipe
(O.D.32)

100

23
A
23

178 (Duct)

Air
inlet

40

238
10

41

32

136

67
356

Model
PEFY-P20-32VMA-E
PEFY-P40-50VMA-E
PEFY-P63-80VMA-E
PEFY-P100-125VMA-E

Air Conditioning
1.5.69 1.121

PEFY-P-VMA-E

700 754 800 660


900 954 1000 860
1100 1154 1200 1060
1400 1454 1500 1360

E
7
9
11
14

600 658
800 858
1000 1058
1300 1358

1.5.70

PEFY-P-VMH(S)-E
High Static Pressure
Ceiling Concealed
Ducted Indoor Unit

With improved design flexibility as a result of increased external static pressure, the PEFY-P-VMH(S)-E allows authentic
duct air conditioning within the strictest aesthetic confines.

Key Features
External static pressure of up to 250Pa
Greater flexibility for duct extension, branching air outlet configuration
Reduced noise levels due to the centrifugal fan
Duct can be connected to intake side
Drain lift-pump (option) 550mm of lift
DC fan motor on P200 and P250

MODEL REFERENCE
Heating (nominal)
Cooling (nominal)
High Performance Heating (UK)
COP Priority Heating (UK)
Cooling (UK)
Hi-Sensible Mode Cooling (UK)
SHF
(UK)
Hi-Sens Mode (UK)
POWER INPUT (kW) Heating (nominal)
Cooling (nominal)
Lo-Hi
AIRFLOW (m3/min)
ExTERNAL STATIC PRESSURE (Pa)
SOUND PRESSURE LEVEL (dBA) (150Pa)
WEIgHT (kg)
DIMENSIONS (mm) Width
Depth
Height
ELECTRICAL SUPPLY
PHASE
RUNNINg CURRENT (A)
Heating
Cooling
FUSE RATINg (BS88) - HRC (A)
MAINS CABLE No. Cores
CAPACITY (kW)

PEFY-P80VMH-E

PEFY-P100VMH-E

PEFY-P125VMH-E

PEFY-P140VMH-E

PEFY-P200VMHS-E

PEFY-P250VMHS-E

10.0
9.0
10.0
9.4
8.5
6.5
0.74
0.83
0.32
0.32
18-25
100-150-200
38-43
50
1000
900
380
220-240v, 50Hz
Single
1.47
1.47
6
3

12.5
11.2
12.5
11.7
10.6
8.1
0.80
0.91
0.48
0.48
26.5-38.0
100-150-200
38-44
70
1200
900
380
220-240v, 50Hz
Single
2.34
2.34
6
3

16.0
14.0
16.0
15.0
13.3
10.2
0.74
0.81
0.48
0.48
26.5-38.0
100-150-200
38-44
70
1200
900
380
220-240v, 50Hz
Single
2.34
2.34
6
3

18.0
16.0
18.0
16.8
15.2
11.6
0.74
0.82
0.48
0.48
28-40
100-150-200
38-44
70
1200
900
380
220-240v, 50Hz
Single
2.35
2.35
6
3

25.0
22.4
25.0
23.4
21.2
16.3
0.75
0.92
0.63
0.63
50-61-72
50-100-150-200-250
36-39-43
97
1250
1120
470
220-240v, 50Hz
Single
3.18
3.18
6
3

31.5
28.0
31.5
29.5
26.5
20.3
0.79
0.90
0.82
0.82
58-71-84
50-100-150-200-250
39-42-46
100
1250
1120
470
220-240v, 50Hz
Single
4.14
4.14
6
3

Product Dimensions

Product Dimensions

PEFY-P80/100/125/140VMH-E

Upper View

Side View

PEFY-P200/250VMHS-E

Upper View

Side View
1120
24

50

Air outlet

15
100

50x(J-1)=K
B (Lifting bolt pitch)

50

23

10010(=1000)
1326(Suspension bolt pitch)
1372

340(Duct)

250

105

100

1100(Duct)

Front View
Front View

1050

1004

930

25

17

800

15

700

PEFY-P100-140VMH-E 1250

1204

1130

25

21

1000

19

900

Model
PEFY-P80VMH-E

Air Conditioning
1.5.71 1.121

PEFY-P-VMH(S)-E

470

1003(=300)
20

100

44

(100)

J-3

Air outlet

15
50

327

422

60

60
50
80

249

95

(100)

23

15

30

60 1003(=300)

250
380

50 50 50 50

77
328
130

94

41 25

50
45
17

30

1124

200
343
387

1034(Suspension bolt pitch)

340

10

G-3

Air inlet

10

814 (Lifting bolt pitch)


904

383

1
92

10

10010(=1000)
100

164

15

41

29

100

847

24
10

50x(G-1)=H

50x5=250

41 F

29

Air inlet

Lifting bolt

489

1250

900
70

1067

1.5.72

PCFY-P-VKM-E

Designed for ultra-quiet operation and easy maintenance, the unit provides comfortable air conditioning for a wide range
of applications where floor or wall space cannot be used practically.

Ceiling Suspended
Indoor Unit

Key Features
Indoor unit designed for direct ceiling suspension
Flush to wall installation for concealment of service connections
Drain piping can be connected from left or right

MODEL REFERENCE
Heating (nominal)
Cooling (nominal)
High Performance Heating (UK)
COP Priority Heating (UK)
Cooling (UK)
Hi-Sensible Mode Cooling (UK)
SHF
(UK)
Hi-Sens Mode (UK)
POWER INPUT (kW) Heating (nominal)
Cooling (nominal)
AIRFLOW (m3/min)
Lo-Mi1-Mi2-Hi
SOUND PRESSURE LEVEL (dBA) Lo-Mi1-Mi2-Hi
WEIgHT (kg)
DIMENSIONS (mm) Width
Depth
Height
ELECTRICAL SUPPLY
PHASE
RUNNINg CURRENT (A)
Heating
Cooling
FUSE RATINg (BS88) - HRC (A)
MAINS CABLE No. Cores
CAPACITY (kW)

PCFY-P40VKM-E

PCFY-P63VKM-E

PCFY-P100VKM-E

PCFY-P125VKM-E

5.0
4.5
5.0
4.7
4.3
3.3
0.72
0.79
0.04
0.04
10-11-12-13
29-32-34-36
24
960
680
230
220-240v, 50Hz
Single
0.28
0.28
6
3

8.0
7.1
8.0
7.5
6.7
5.2
0.72
0.77
0.05
0.05
14-15-16-18
31-33-35-37
32
1280
680
230
220-240v, 50Hz
Single
0.33
0.33
6
3

12.5
11.2
12.5
11.7
10.6
8.1
0.70
0.75
0.09
0.09
21-24-26-28
36-38-41-43
36
1600
680
230
220-240v, 50Hz
Single
0.65
0.65
6
3

16.0
14.0
16.0
15.0
13.3
10.2
0.69
0.75
0.11
0.11
21-24-27-31
36-39-42-44
38
1600
680
230
220-240v, 50Hz
Single
0.76
0.76
6
3

Product Dimensions

PCFY-P40VKM-E

Front View

Side View

PCFY-P63VKM-E

Front View

Side View

51

51

10

1280

10

88

230

1173

84

84

88

195

853

230

960

195

Air outlet

184
203

Air outlet

(liquid 6.35)
(gas 12.7)

180
200
233

233

246

254

254

476

476

680

680

57

57

246

Air intake

182

Air intake

85

182

85

1198

878

Lower View

Product Dimensions

Lower View

PCFY-P100/125VKM-E

Front View

Side View
51
1600

10

1493

88

230

84

195

236

180

Air outlet

200

(liquid 9.52)
(gas 15.88)

233

254

476

680

57

246

182

Air intake

85

1518

Lower View

Air Conditioning
1.5.73 1.121

236

Product Dimensions

PCFY-P-VKM-E

(liquid 9.52)
(gas 15.88)

1.5.74

PKFY-P-VBM-E /
VHM-E/ VKM-E
Wall Mounted Indoor Units

An elegant design combined with compact dimensions and quiet operation make the PKFY-P an ideal unit choice.
Noise levels are significantly reduced thanks to a unique airflow passage design that not only makes the unit one of
the quietest in the industry, but also suppresses condensation and prevents mixing with secondary air.

Key Features
Compact flat panel design - only 815mm wide (VBM-E)
Front grille opening for easy cleaning
Front power supply for easy wiring after installation
5-way piping provides more flexibility in selection of installation sites

MODEL REFERENCE
Heating (nominal)
Cooling (nominal)
High Performance Heating (UK)
COP Priority Heating (UK)
Cooling (UK)
Hi-Sensible Mode Cooling (UK)
SHF
(UK)
Hi-Sens Mode (UK)
POWER INPUT (kW) Heating (nominal)
Cooling (nominal)
AIRFLOW (m3/min)
Lo-Mi1-Mi2-Hi
SOUND PRESSURE LEVEL (dBA) Lo-Mi1-Mi2-Hi
WEIgHT (kg)
DIMENSIONS (mm) Width
Depth
Height
ELECTRICAL SUPPLY
PHASE
RUNNINg CURRENT (A)
Heating
Cooling
FUSE RATINg (BS88) - HRC (A)
MAINS CABLE No. Cores
CAPACITY (kW)

PKFY-P15VBM-E

PKFY-P20VBM-E

PKFY-P25VBM-E

PKFY-P32VHM-E

PKFY-P40VHM-E

PKFY-P50VHM-E

PKFY-P63VKM-E

1.9
1.7
1.9
1.8
1.6
1.2
0.75
0.83
0.04
0.04
4.9-5.0-5.2-5.3
29-31-32-33
10
815
225
295
220-240v, 50Hz
Single
0.20
0.20
6
3

2.5
2.2
2.5
2.3
2.1
1.6
0.71
0.75
0.04
0.04
4.9-5.2-5.6-5.9
29-31-34-36
10
815
225
295
220-240v, 50Hz
Single
0.20
0.20
6
3

3.2
2.8
3.2
3.0
2.7
2.0
0.70
0.80
0.04
0.04
4.9-5.2-5.6-5.9
29-31-34-36
10
815
225
295
220-240v, 50Hz
Single
0.20
0.20
6
3

4.0
3.6
4.0
3.7
3.4
2.6
0.76
0.85
0.03
0.04
9-10-11
34-37-41
13
898
249
295
220-240v, 50Hz
Single
0.30
0.40
6
3

5.0
4.5
5.0
4.7
4.3
3.3
0.74
0.82
0.03
0.04
9-10.5-11.5
34-38-41
13
898
249
295
220-240v, 50Hz
Single
0.30
0.40
6
3

6.3
5.6
6.3
5.9
5.3
4.1
0.72
0.78
0.03
0.04
9-10.5-12
34-39-43
13
898
249
295
220-240v, 50Hz
Single
0.30
0.40
6
3

8.0
7.1
8.0
7.5
6.7
5.2
0.78
0.85
0.04
0.05
16-20
39-45
21
1170
295
365
220-240v, 50Hz
Single
0.30
0.37
6
3

Product Dimensions

PKFY-P15/20/25VBM-E
815
640 Air intake

225

115

Air intake
(Direction)

106.7
3

Side View

295

Front View

640 Air intake


695 Air outlet

37.8

Air outlet

Air intake
(Direction)

Air outlet
74.6

60

Air outlet
(Direction)

Product Dimensions

PKFY-P32/40/50VHM-E

Side View
295

Front View

55

688

155

249

898

Product Dimensions

PKFY-P63VKM-E

Side View
365

Front View

74

(855)

241

295

1170

Air Conditioning
1.5.75 1.121

PKFY-P-VBM-E / VHM-E / VKM-E

1.5.76

PFFY-P-VLRM-E

A compact concealed unit providing simple, effective air conditioning in perimeter zones. The unit is easy to install
and at only 220mm deep offers an unobtrusive method of delivering highly efficient air-conditioning performance.

Floor Standing Concealed


Indoor Unit

Key Features
Concealed unit for hidden installation
Ideal for perimeter refurbishments

MODEL REFERENCE
Heating (nominal)
Cooling (nominal)
High Performance Heating (UK)
COP Priority Heating (UK)
Cooling (UK)
Hi-Sensible Mode Cooling (UK)
SHF
(UK)
Hi-Sens Mode (UK)
POWER INPUT (kW) Heating (nominal)
Cooling (nominal)
AIRFLOW (m3/min)
Lo-Hi
SOUND PRESSURE LEVEL (dBA) Lo-Hi
WEIgHT (kg)
DIMENSIONS (mm) Width
Depth
Height
ELECTRICAL SUPPLY
PHASE
RUNNINg CURRENT (A)
Heating
Cooling
FUSE RATINg (BS88) - HRC (A)
MAINS CABLE No. Cores
CAPACITY (kW)

PFFY-P20VLRM-E

PFFY-P25VLRM-E

PFFY-P32VLRM-E

PFFY-P40VLRM-E

PFFY-P50VLRM-E

PFFY-P63VLRM-E

2.5
2.2
2.5
2.3
2.1
1.6
0.81
0.88
0.04
0.04
5.5-6.5
34-40
18.5
886
220
639
220-240v, 50Hz
Single
0.19
0.19
6
3

3.2
2.8
3.2
3.0
2.7
2.0
0.70
0.80
0.04
0.04
5.5-6.5
34-40
18.5
886
220
639
220-240v, 50Hz
Single
0.19
0.19
6
3

4.0
3.6
4.0
3.7
3.4
2.6
0.74
0.81
0.06
0.06
7-9
35-40
20
1006
220
639
220-240v, 50Hz
Single
0.29
0.29
6
3

5.0
4.5
5.0
4.7
4.3
3.3
0.72
0.79
0.065
0.065
9-11
38-43
21
1006
220
639
220-240v, 50Hz
Single
0.32
0.32
6
3

6.3
5.6
6.3
5.9
5.3
4.1
0.74
0.80
0.085
0.085
12-14
38-43
25
1246
220
639
220-240v, 50Hz
Single
0.40
0.40
6
3

8.0
7.1
8.0
7.5
6.7
5.2
0.73
0.79
0.10
0.10
12-15.5
40-46
27
1246
220
639
220-240v, 50Hz
Single
0.46
0.46
6
3

Product Dimensions

PFFY-P20/25/32/40/50/63VLRM-E

Upper View

132

15

Side View

167
A

Air outlet
220
98

84

C
30 8

49

120

Air outlet

50

90

10
29

80

35

( 75 )

170

430

400

639

300

310

100

15

Air
inlet

90

Air filter

Air inlet

45
76

15

Front View

Air Conditioning
1.5.77 1.121

PFFY-P-VLRM-E

Model

PEFY-P20VLRM-E

886

640

572

610

360
360

PEFY-P25VLRM-E

886

640

572

610

PEFY-P32VLRM-E

1006

760

692

730

480

PEFY-P40VLRM-E

1006

760

692

730

480

PEFY-P50VLRM-E

1246

1000

932

970

720

PEFY-P63VLRM-E

1246

1000

932

970

720

1.5.78

PFFY-P-VLRMM-E

A compact concealed unit providing simple, effective air conditioning in perimeter zones. The unit is easy to install
and at only 220mm deep offers an unobtrusive method of delivering highly efficient air-conditioning performance.

Floor Standing Concealed


Indoor Unit

Key Features
Reduced noise levels
3 static pressure settings - 20/40/60Pa ideal for ducting in the perimeter zone
Concealed unit for hidden installation. the unit can be hidden behind a wardrobe in a hotel, then ducted
above and below the wardrobe doors - this offers lower noise, less disruption and a low visual impact

MODEL REFERENCE
Heating (nominal)
Cooling (nominal)
High Performance Heating (UK)
COP Priority Heating (UK)
Cooling (UK)
Hi-Sensible Mode Cooling (UK)
SHF
(UK)
Hi-Sens Mode (UK)
POWER INPUT (kW) Heating (nominal)
Cooling (nominal)
AIRFLOW (m3/min)
Lo-Mi-Hi
ExTERNAL STATIC PRESSURE (Pa)
SOUND PRESSURE LEVEL (dBA) (20Pa) Lo-Mi-Hi
WEIgHT (kg)
DIMENSIONS (mm) Width
Depth
Height
ELECTRICAL SUPPLY
PHASE
RUNNINg CURRENT (A)
Heating
Cooling
FUSE RATINg (BS88) - HRC (A)
MAINS CABLE No. Cores
CAPACITY (kW)

PFFY-P20VLRMM-E

PFFY-P25VLRMM-E

PFFY-P32VLRMM-E

PFFY-P40VLRMM-E

PFFY-P50VLRMM-E

PFFY-P63VLRMM-E

2.5
2.2
2.5
2.3
2.1
1.6
0.81
0.88
0.04
0.04
4.5-5.5-6.5
20-40-60
31-36-40
18.5
886
220
639
220-240v, 50Hz
Single
0.34
0.34
6
3

3.2
2.8
3.2
3.0
2.7
2.0
0.70
0.80
0.04
0.04
4.5-5.5-6.5
20-40-60
31-36-40
18.5
886
220
639
220-240v, 50Hz
Single
0.34
0.34
6
3

4.0
3.6
4.0
3.7
3.4
2.6
0.74
0.81
0.04
0.04
6.5-7.5-9
20-40-60
27-32-37
20
1006
220
639
220-240v, 50Hz
Single
0.38
0.38
6
3

5.0
4.5
5.0
4.7
4.3
3.3
0.72
0.79
0.05
0.05
8-9.5-11
20-40-60
30-36-40
21
1006
220
639
220-240v, 50Hz
Single
0.43
0.43
6
3

6.3
5.6
6.3
5.9
5.3
4.1
0.74
0.80
0.05
0.05
10-12-14
20-40-60
32-37-41
25
1246
220
639
220-240v, 50Hz
Single
0.48
0.48
6
3

8.0
7.1
8.0
7.5
6.7
5.2
0.73
0.79
0.07
0.07
11-13-15.5
20-40-60
35-40-44
27
1246
220
639
220-240v, 50Hz
Single
0.59
0.59
6
3

Product Dimensions

PFFY-P20/25/32/40/50/63VLRMM-E

Upper View

35

B(Wall mounting hole pitch)

33

77

103

88

Side View
175

68
A
220

C
E
120

Air outlet

385
639
400
75

170

344

387

300
(Wall mounting hole pitch)

43

98 30 8
49

10
29

84

9
90

15
45
76

Air inlet
D

15

Front View

Air Conditioning
1.5.79 1.121

PFFY-P-VLRMM-E

Model

PFFY-P20VLRMM-E

886

640

572

610

360
360

PFFY-P25VLRMM-E

886

640

572

610

PFFY-P32VLRMM-E

1006

760

692

730

480

PFFY-P40VLRMM-E

1006

760

692

730

480

PFFY-P50VLRMM-E

1246

1000

932

970

720

PFFY-P63VLRMM-E

1246

1000

932

970

720

1.5.80

PFFY-P-VLEM-E

A compact cased unit providing simple, effective air conditioning in perimeter zones. The unit is easy to install,
and at only 220mm deep offers an unobtrusive method of delivering a highly efficient air conditioning performance.

Floor Standing Exposed


Indoor Unit

Key Features
Remote controller can be incorporated into the main unit
Perimeter air conditioning for retrofit applications with low ceiling void

MODEL REFERENCE
Heating (nominal)
Cooling (nominal)
High Performance Heating (UK)
COP Priority Heating (UK)
Cooling (UK)
Hi-Sensible Mode Cooling (UK)
SHF
(UK)
Hi-Sens Mode (UK)
POWER INPUT (kW) Heating (nominal)
Cooling (nominal)
AIRFLOW (m3/min)
Lo-Hi
SOUND PRESSURE LEVEL (dBA) Lo-Hi
WEIgHT (kg)
DIMENSIONS (mm) Width
Depth
Height
ELECTRICAL SUPPLY
PHASE
RUNNINg CURRENT (A)
Heating
Cooling
FUSE RATINg (BS88) - HRC (A)
MAINS CABLE No. Cores
CAPACITY (kW)

PFFY-P20VLEM-E

PFFY-P25VLEM-E

PFFY-P32VLEM-E

PFFY-P40VLEM-E

PFFY-P50VLEM-E

PFFY-P63VLEM-E

2.5
2.2
2.5
2.3
2.1
1.6
0.81
0.88
0.04
0.04
5.5-6.5
34-40
23
1050
220
630
220-240v, 50Hz
Single
0.19
0.19
6
3

3.2
2.8
3.2
3.0
2.7
2.0
0.70
0.80
0.04
0.04
5.5-6.5
34-40
23
1050
220
630
220-240v, 50Hz
Single
0.19
0.19
6
3

4.0
3.6
4.0
3.7
3.4
2.6
0.74
0.81
0.06
0.06
7-9
35-40
25
1170
220
630
220-240v, 50Hz
Single
0.29
0.29
6
3

5.0
4.5
5.0
4.7
4.3
3.3
0.72
0.79
0.065
0.065
9-11
38-43
26
1170
220
630
220-240v, 50Hz
Single
0.32
0.32
6
3

6.3
5.6
6.3
5.9
5.3
4.1
0.74
0.80
0.085
0.085
12-14
38-43
30
1410
220
630
220-240v, 50Hz
Single
0.40
0.40
6
3

8.0
7.1
8.0
7.5
6.7
5.2
0.73
0.79
0.10
0.10
12-15.5
40-46
32
1410
220
630
220-240v, 50Hz
Single
0.46
0.46
6
3

Product Dimensions

PFFY-P20/25/32/40/50/63VLEM-E

40

120

(60)

Upper View

Front View
A
80

170

170

300

310

78

108

15

160

15

Air filter
10

45
220

Air Conditioning
1.5.81 1.121

10
D

220

PFFY-P-VLEM-E

Model

PFFY-P20VLEM-E

1050

640

600

610
610

PFFY-P25VLEM-E

1050

640

600

PFFY-P32VLEM-E

1170

760

720

730

PFFY-P40VLEM-E

1170

760

720

730

PFFY-P50VLEM-E

1410

1000

960

970

PFFY-P63VLEM-E

1410

1000

960

970

1.5.82

PFFY-P-VKM-E
Floor Standing Exposed
Indoor Unit

The PFFY-P-VKM-E series is extremely versatile and is designed for wall attached installation at floor level.
The auto swing vane provides a more natural and comfortable airflow throughout the room and the lightweight,
compact design makes installation easy.

Key Features
Pure white, slimline design
Upper and lower vanes for optimum, powerful and efficient air distribution

MODEL REFERENCE
Heating (nominal)
Cooling (nominal)
High Performance Heating (UK)
COP Priority Heating (UK)
Cooling (UK)
Hi-Sensible Mode Cooling (UK)
SHF
(UK)
Hi-Sens Mode (UK)
POWER INPUT (kW) Heating (nominal)
Cooling (nominal)
AIRFLOW (m3/min)
Lo-Mi1-Mi2-Hi
SOUND PRESSURE LEVEL (dBA) Lo-Mi1-Mi2-Hi
WEIgHT (kg)
DIMENSIONS (mm) Width
Depth
Height
ELECTRICAL SUPPLY
PHASE
RUNNINg CURRENT (A)
Heating
Cooling
FUSE RATINg (BS88) - HRC (A)
MAINS CABLE No. Cores
CAPACITY (kW)

PFFY-P20VKM-E

PFFY-P25VKM-E

PFFY-P32VKM-E

PFFY-P40VKM-E

2.5
2.2
2.5
2.3
2.1
1.6
0.81
0.88
0.025
0.025
5.9-6.8-7.6-8.7
27-31-34-37
15
700
200
600
220-240v, 50Hz
Single
0.20
0.20
6
3

3.2
2.8
3.2
3.0
2.7
2.0
0.74
0.85
0.025
0.025
6.1-7.0-8.0-9.1
28-32-35-38
15
700
200
600
220-240v, 50Hz
Single
0.20
0.20
6
3

4.0
3.6
4.0
3.7
3.4
2.6
0.71
0.77
0.025
0.025
6.1-7.0-8.0-9.1
28-32-35-38
15
700
200
600
220-240v, 50Hz
Single
0.20
0.20
6
3

5.0
4.5
5.0
4.7
4.3
3.3
0.70
0.76
0.028
0.028
8.0-9.0-9.5-10.7
35-38-42-44
15
700
200
600
220-240v, 50Hz
Single
0.24
0.24
6
3

Product Dimensions

PFFY-P20/25/32/40VKM-E

Upper View

Front View
Side View

More than
100mm

46.5

12

200

12

700
607

46.5

Air out

More than
100mm

More than
100mm

Air in

118

600

96

Gas pipe
12.7(flared)1/2
Liquid pipe
6.35(flared)1/4

11

54

508

137

12

165
205

125

19

Drain pipe
O.D. 16 (5/8")

60

123

Air out

60
128

Air Conditioning
1.5.83 1.121

PFFY-P-VKM-E

1.5.84

PAC-LV11M

The PAC-LV11M allows our new M Series indoor unit models to be connected to the City Multi range.
The LEV kit can for instance be installed in the ceiling void of the corridor of a hotel and will therefore
minimise noise within the bedroom.

LEV Kit Interface


Key Features
Compatible with MSZ-SF20VA and MSZ-EF indoor units
Compact size
No need for drain pipe
Up to 10m between the LEV kit and the indoor unit
Now connectable to PUMY-P V/YKM outdoor units

MODEL REFERENCE
MAx NO. OF CONNECTABLE INDOOR UNITS
CAPACITY OF INDOOR UNITS
COMPATIBLE OUTDOOR UNITS
PIPE SIZE mm (in)
Gas
Liquid
WEIgHT (kg)
DIMENSIONS (mm) Width
Depth
Height
ELECTRICAL SUPPLY
PHASE
FUSE RATINg (BS88) - HRC (A)
MAINS CABLE No. Cores

PAC-LV11M
1
20 to 50
PUH(R)Y-(E)P / PQH(R)Y-(E)P / PUMY-P V/YKM
6.35 (1/4)
3.5
355
142
183
220-240v, 50Hz
Single
6
3

CONNECtABLE INDOOR UNItS


MSZ-EF25VE-B/S/W
MSZ-EF35VE-B/S/W
MSZ-EF50VE-B/S/W

MSZ-SF20VA

Notes: Cant be grouped with City Multi indoor units. Group control via ME controller or system controller only. Group control is not possible via an MA controller, IT terminal or wireless remote controller.

Product Dimensions

PAC-LV11M

Upper View
280
250

20

240

100

69

142

62

15

Front View

Side View
109

110

11

34

62

65

183

213

15

250
280
355

Air Conditioning
1.5.85 1.121

PAC-LV11M

1.5.86

GUF-RD4
Lossnay Outdoor
Air Processing
Indoor Unit

The gUF-50RD4 and gUF-100RD4 outdoor air processing units can be used with any of the extensive range
of City Multi indoor units to provide ventilation, dust removal, humidification and heat recovery.

Key Features
A combination of a Lossnay & City Multi indoor in a single unit
Air temperature in any room can be adjusted to the desired temperature via this unit which is used as an indoor unit
of the City Multi air conditioning system
the ventilating and air conditioning functions are integrated in a single unit, saving space and installation costs
Heat recovery helps to save energy - a benefit thats not only good for the environment, but also great for cutting energy costs
Free cooling is also available should outdoor conditions be suitable

MODEL REFERENCE
Heating (nominal)
Cooling (nominal)
High Performance Heating (UK)
COP Priority Heating (UK)
Cooling (UK)
POWER INPUT (kW) Lo-Hi
3
AIRFLOW (m /h)
Lo-Hi
ExTERNAL STATIC PRESSURE (Pa)
SOUND PRESSURE LEVEL (dBA) Lo-Hi
WEIgHT (kg)
DIMENSIONS (mm) Width
Depth
Height
ELECTRICAL SUPPLY
PHASE
RUNNINg CURRENT (A)
Lo-Hi
FUSE RATINg (BS88) - HRC (A)
MAINS CABLE No. Cores
CAPACITY (kW)

GUF-50RD4

GUF-100RD4

6.21 (2.04)
5.57 (1.94)
6.42 (2.25)
5.93 (2.08)
5.03 (1.58)
0.150 / 0.265
400-500
140
29.5-34.5
54
1016
1288
317
220-240v, 50Hz
Single
0.70-1.15
6
3

12.56 (4.26)
11.44 (4.12)
13.00 (4.70)
12.01 (4.34)
10.27 (3.32)
0.370 / 0.505
800-1000
140
34-39
92
1231
1580
398
220-240v, 50Hz
Single
1.73-2.20
6
3

Notes: The figures in ( ) indicates the heat recovery at Lossnay core. Total value is capacity of Lossnay core and refrigerant coil. The current and input are based on the above air volume.
The sound pressure at the air outlets (45 angle 1.5m ahead) is about 6dB greater than the indicated value. (High notch). Specifications may be subject to change without notice.

Product Dimensions

GUF-RD4

Side View

Upper View

Side View

Position where duct direction change is possible


Damper plate

C
D

Ceiling suspension fixture

Air exhaust fan


EA
(Exhaust air)

RA
(Return air)

Model

Air supply fan

SA
(Supply air)

G
Inspection
opening

Inspection
opening
H

Maintenance cover

Air Conditioning
1.5.87 1.121

S
Gas pipe (Flare T)

Air filters

Liquid pipe (Flare U)

Position where duct direction


change is possible

Drain discharge hole


[O.D. 32mm (1-1/4inch), I.D. 25mm (1inch)]

398 1,580 149 280 242 258 15.88 9.52 361 169

Maintenance cover(humidifier)

30

W
Ceiling
suspension
fixture

GUF-100RD3

79

317 1,288 124 266 192 208 12.7 6.35 347 135

GUF-50RD3

Direct Expansion coil

N
60

79

High-efficiency filter
(Optional parts)

149 600 460 670 199

Front View
Heat recovery unit
(Lossnay Core)

920 1,231 149 1,465 1,271 16

Power supply opening

Control box

GUF-100RD3

Maintenance space for


Heat exchanger

124 450 372.5 435 158.5

20

600 or more

150-250

Maintenance space for


Heat recovery unit
(Lossnay Core)
Air filters, Blower
High-efficiency filter

745 1,016 124 1,185 1,048 22

Model
100

OA
(Outdoor air)

GUF-50RD3

GUF-RD4

1.5.88

PWFY-P
VRF Heat Pump Boiler

Taking full advantage of heat recovery technology, the Mitsubishi Electric booster unit (PWFY-P100VM-E-BU) can achieve
a flow temperature of up to 70C and is an ideal solution for providing a hot water supply to commercial buildings in an
energy efficient manner.

Key Features
the benefit of having air conditioning as well as a hot water supply from a single system means that the unit is suitable
for a variety of applications
Simple addition of the booster unit to the existing air conditioning system
Perfect solution that allows inconveniences that arise when installing gas boilers such as gas grid connection costs,
meter installation and maintenance costs to be eliminated
Uses the PAR-W21MAA controller

MODEL REFERENCE
CAPACITY (kW)

Hot water (nominal)*1


Hot water (UK)*2

POWER INPUT (kW)


COMPATIBLE OUTDOOR / CONDENSINg UNITS
REFRIgERANT CHARgE (kg) High Temp Circuit
PIPE SIZE mm (in)
Gas
Liquid
Water Connection
Water pipe size
SOUND PRESSURE LEVEL (dBA)
MAx WATER TEMPERATURE (C)
OPTIMUM WATER FLOW RATE (m3/h)
WATER PRESSURE DROP AT OPTIMUM FLOW RATE (kPa)
WEIgHT (kg)
DIMENSIONS (mm) Width
Depth
Height
ELECTRICAL SUPPLY
PHASE
RUNNINg CURRENT (A)
FUSE RATINg (BS88) - HRC (A)
MAINS CABLE No. Cores

PWFY-P100VM-E-BU
12.50
8
2.4
PURY / PQRY
1.1 (R134a)
15.88 (5/8")
9.52 (3/8")
PT 3/4 Screw
28
44
70
1.5
22.5
60
450
300
785 (800)
220-240v, 50Hz
Single
10.66
25
3

Notes:
*1 Nominal conditions: Outdoor 7/6C , 65C inlet water temperature, 1.5m3/h water flow rate, 7.5m refrigerant pipe. (Please note this is a spot condition and not capacity over tank heat up).
*2 Typical capacity at -10CWB outdoor temperature for tank heat up.

Product Dimensions

PWFY-P100VM-E-BU

205
(Mounting pitch)
300

Upper View

450
500
(Mounting pitch)
525

Front View

Side View

Control box
35

480

91

800

Water outlet
(RC3/4 screw)

134

Service panel

35
55

Air Conditioning
1.5.89 1.121

191
54

102

100

91

114

Drain (R1 screw)


206

PWFY-P

1.5.90

VRF HP DXE
Heat Pump Air Curtain

In collaboration with Thermoscreens, Mitsubishi Electric have developed a range of heat pump air curtains that are able to be
connected to our City Multi VRF systems, as opposed to the more traditional direct electric method associated with air curtains.

Key Features
Reduced CO2 emissions
Reduced running costs
Inverter technology (does not waste energy)
Range of different sizes to suit every application
Allows open door policy in retail outlets whilst being energy efficient
Clean environment - protection from dust, fumes etc
Comfortable climate for customers
Easy to install and maintain
Heat recovery possible, optimising energy use

VRF HP DXE - RECESSED


Heating (nominal)
Cooling (nominal)
3/h)
AIR VOLUME MAx (m
SOUND PRESSURE LEVEL AT 3m (dBA) Lo-Mi1-Hi
WEIgHT (kg)
DIMENSIONS (mm) Width
Depth
Height
ELECTRICAL SUPPLY*1
1
PHASE*
RUNNINg CURRENT (A)*1
MAINS CABLE No. Cores*1
UNIFORMITY AT OUTLET (%)*2
UNIT SIZE (Index)
MAx MOUNTINg HEIgHT (m)
COMPATIBLE OUTDOOR UNITS
CAPACITY (kW)

VRF HP DXE - FREE STANDING


Heating (nominal)
Cooling (nominal)
3/h)
AIR VOLUME MAx (m
SOUND PRESSURE LEVEL AT 3m (dBA) Lo-Mi1-Hi
WEIgHT (kg)
DIMENSIONS (mm) Width
Depth
Height
ELECTRICAL SUPPLY*1
PHASE*1
RUNNINg CURRENT (A)*1
MAINS CABLE No. Cores*1
UNIFORMITY AT OUTLET (%)*2
UNIT SIZE (Index)
MAx MOUNTINg HEIgHT (m)
COMPATIBLE OUTDOOR UNITS
CAPACITY (kW)

VRF HP1000R DXE

VRF HP1500R DXE

VRF HP2000R DXE

8.3
7.4
1310
50-55-58
52
1250
348
539
220-240v, 50Hz
Single
0.8
3
90
P71
3.3
PUHY / PURY / PQHY / PQRY

13.2
11.8
2070
49-54-58
75
1750
348
539
220-240v, 50Hz
Single
1.2
3
92
P125
3.3
PUHY / PURY / PQHY / PQRY

15.7
14.0
2590
50-55-58
93
2340
348
539
220-240v, 50Hz
Single
1.4
3
90
P140
3.3
PUHY / PURY / PQHY / PQRY

VRF HP1000 DXE

VRF HP1500 DXE

VRF HP2000 DXE

8.3
7.4
1310
50-55-58
46
1300
468
306
220-240v, 50Hz
Single
0.8
3
90
P71
3.3
PUHY / PURY / PQHY / PQRY

13.2
11.8
2070
49-54-58
67
1825
468
306
220-240v, 50Hz
Single
1.2
3
92
P125
3.3
PUHY / PURY / PQHY / PQRY

15.7
14
2590
50-55-58
84
2350
468
306
220-240v, 50Hz
Single
1.4
3
90
P140
3.3
PUHY / PURY / PQHY / PQRY

Notes: *1 For indoor units with electric defrost heaters enabled, 3ph, 380-415V power supply (7.3A HP1000, 12.1A HP1500, 14.4A HP2000). *2 Tested to ISO27327.

Product Dimensions

VRF HP1000/1500/2000R DX-E

Front View

Upper View

Side View

25

485

115

Gas Line
Refrigerant
Connection (G)

20mm hole for gravity or pumped


condensate disposal (if cooling)

CEILING LEVEL

CEILING LEVEL

200

Liquid Line Refrigerant


Connection (L)

348

100

200

265

20mm hole on top for pumped


condensate disposal (if cooling)

Electrical Supply
and Mitsubishi
Wiring Inlets (M20)

Additional (M20)
Wiring Inlets on top

100

65

Holes for M10 drop rods


4 for 1m unit,
5 for 1.5m & 2m units
Use all drop rod holes !

Liquid Line Refrigerant Connection (L)

Gas Line Refrigerant Connection (G)

A
B

25

D
Model

539

Cut-Out
in Ceiling

Product Dimensions

Upper View

724

25

1129

C (mm)

976

1161

D (mm)

1303

1803

2393

E (mm)

170

166

189

8 in.

2 in.

8 in.

2 in.

8 in.

8 in.

Length (mm)

1250

1750

2340

Width (mm)

485

485

485

50

45

45 45

1.5m only

Model

AIR IN
200

250

Inserts for M10 drop rods


4 for 1m unit, 6 for 1.5m/2m units
Use all drop rod holes !

Gas
Line
(G)

306

340

Liquid
Line
(L)
100

15

105

20

20mm hole for gravity or pumped


condensate disposal (if cooling)

VRF HP1000DxE VRF HP1500DxE VRF HP2000DxE

A (mm)

1300

1825

2350

B (mm)

605

1225

1793

C (mm)

655

918

D (mm)

898

1398

1904
952

AIR OUT

E (mm)

699

468

F (mm)

182

222

H (mm)

442

333

299

I (mm)

253

267

258

J (mm)

359

359

334

K (mm)

80

45

L
M

Air Conditioning
1.5.91 1.121

2340

Gas Line
Refrigerant
Connection (G)

225

1750

Side View

Recommend
250 minimum
for pipes

20mm hole on top for pumped


condensate disposal (if cooling)

Liquid Line
Refrigerant
Connection (L)

Electrical Supply and Mitsubishi


Control Wiring Inlets (M20)
A

1250

B (mm)

VRF HP1000/1500/2000 DX-E

Front View

Additional (M20)
Wiring Inlets on top

VRF HP1000R DxE VRF HP1500R DxE VRF HP2000R DxE

A (mm)

VRF HP DXE

8 in.

2 in.

8 in.

2 in.

204
8 in.

80
8 in.

570

875

1.5.92

BC Controllers

At the heart of both the R2 and WR2 Series, the BC controller makes simultaneous heating and cooling possible.
It has the inherent intelligence to be the systems decision-maker.

Key Features
transferring energy around the system
Drawing on energy from the heat source units/outdoor units
Directing energy as requested by the individual indoor units
Instructs the heat source unit/outdoor unit on the amount of refrigerant (liquid or gas) that is required to achieve the requested cooling or heating requirements
Allows unique 2-pipe heat recovery application
HIC Circuit for improved efficiency
Brazed connections
Isolation valves factory-fitted on each port

BC CONTROLLERS
NUMBER OF CONNECTIONS
WEIgHT (kg)
DIMENSIONS (mm)
Width
Depth
Height
ELECTRICAL SUPPLY
PHASE
POWER INPUT (kW)
RUNNINg CURRENT (A)
FUSE RATINg (BS88) HRC (A)
MAINS CABLE No. Cores

CMB-P104V-G1

CMB-P105V-G1

CMB-P106V-G1

4
24
648
432
284
220-240v, 50Hz
Single
0.085
0.36
6
3

5
27
648
432
284
220-240v, 50Hz
Single
0.104
0.44
6
3

6
28
648
432
284
220-240v, 50Hz
Single
0.123
0.52
6
3

Note: CMB-P-V-G1 units are for use with PURY-P200-350 YJM-A, PURY-EP200-350 YKM-A & PQRY-P200-300YHM-A units only.

MASTER BC CONTROLLERS
NUMBER OF CONNECTIONS
WEIgHT (kg)
DIMENSIONS (mm)
Width
Depth
Height
ELECTRICAL SUPPLY
PHASE
POWER INPUT (KW)
RUNNINg CURRENT (A)
FUSE RATINg (BS88) HRC (A)
MAINS CABLE No. Cores

CMB-P108V-GA1

CMB-P1010V-GA1

CMB-P1013V-GA1

CMB-P1016V-GA1

CMB-P1016V-HA1

8
43
1110
520
289
220-240v, 50Hz
Single
0.161
0.68
6
3

10
48
1110
520
289
220-240v, 50Hz
Single
0.198
0.83
6
3

13
55
1110
520
289
220-240v, 50Hz
Single
0.255
1.07
6
3

16
62
1110
520
289
220-240v, 50Hz
Single
0.312
1.30
6
3

16
69
1110
520
289
220-240v, 50Hz
Single
0.312
1.30
6
3

Notes: CMB-P-V-GA1 units are for use with PURY-P200-650Y(S)JM-A(1), PURY-EP200-650Y(S)KM-A & PQRY-P200-600Y(S)HM-A units only. CMB-P1016V-HA1 unit is for use with PURY-P700-900YSJM-A & PURY-EP700YSKM-A units only.

SLAVE BC CONTROLLERS
NUMBER OF CONNECTIONS
WEIgHT (kg)
DIMENSIONS (mm)
Width
Depth
Height
ELECTRICAL SUPPLY
PHASE
POWER INPUT (KW)
RUNNINg CURRENT (A)
FUSE RATINg (BS88) HRC (A)
MAINS CABLE No. Cores

CMB-P104V-GB1

CMB-P108V-GB1

CMB-P1016V-HB1

4
22
648
432
284
220-240v, 50Hz
Single
0.076
0.32
6
3

8
32
648
432
284
220-240v, 50Hz
Single
0.151
0.63
6
3

16
55
1098
432
284
220-240v, 50Hz
Single
0.301
1.26
6
3

Product Dimensions

Control box

Upper View

Control box

388
(Lifting bolt pitch)

362

298
(Lifting bolt pitch)

Upper View

648
702
(Lifting bolt pitch)
46

1110
1164
(Lifting bolt pitch)

60XA=B
90

46

60
200

Product Dimensions

76

60XA=B

10

11

12

13

14

15

16

CMB-P108V-gA1

420
540

180

CMB-P1010V-gA1

CMB-P105V-g1

240

CMB-P1013V-gA1

12

720

CMB-P106V-g1

300

CMB-P1016V-gA1/HA1

15

900

60
60XA=B

76

200

Product Dimensions

CMB-P104/108V-GB1

CMB-P1016HB1

Control box

Upper View

298
(Lifting bolt pitch)

Upper View

1098
1152
(Lifting bolt pitch)

90

46

27

CMB-P104-gB1

180

CMB-P108V-gB1

420

10 11 12 13 14 15 16

255

60X15=900
60

128
58

Side View
A

284

Side View

60
200

Air Conditioning
1.5.93 1.121

CMB-P104V-g1

70

74

128

90

289
260

58

Side View

255

284

128

Side View

60XA=B
60

27

27

60

76

BC Controllers

60X15=900

362

90

70

CMB-P108/1010/1013/1016V-GA1/HA1

70

CMB-P104/105/106V-G1

450

Product Dimensions

1.5.94

BC Controllers
With Port Isolation
Valves

At the heart of both the R2 and WR2 Series, the BC controller makes simultaneous heating and cooling possible. It has the inherent intelligence
to be the systems decision-maker. The BC controllers are now available with factory-fitted isolation valves on each port. By isolating individual
ports, and therefore fan coils, this product enables the VRF system to still operate whilst installation or maintenance is carried out in individual rooms.

Key Features
transferring energy around the system
Drawing on energy from the heat source units/outdoor units
Directing energy as requested by the individual indoor units
Instructs the heat source unit/outdoor unit on the amount of refrigerant (liquid or gas) that is required to achieve the requested cooling or heating requirements
Allows unique 2-pipe heat recovery application
HIC Circuit for improved efficiency
Brazed connections
Isolation valves factory-fitted on each port
BC CONTROLLERS
NUMBER OF CONNECTIONS
WEIgHT (kg)
DIMENSIONS (mm)
Width
Depth
Height
ELECTRICAL SUPPLY
PHASE
POWER INPUT (kW)
RUNNINg CURRENT (A)
FUSE RATINg (BS88) HRC (A)
MAINS CABLE No. Cores
BC Box

KS8-CMB-P104V-G1

KS8-CMB-P105V-G1

KS8-CMB-P106V-G1
6
28 + 5.9
648
432 + 280
284
220-240v, 50Hz
Single
0.123
0.52
6
3
CMB-P106V-g1

5
27 + 5
648
432 + 280
284
220-240v, 50Hz
Single
0.104
0.44
6
3
CMB-P105V-g1

4
24 + 4.2
648
432 + 280
284
220-240v, 50Hz
Single
0.085
0.36
6
3
CMB-P104V-g1

Note: KS8-CMB-P-V-G1 units are for use with PURY-P200-350 YJM-A, PURY-EP200-350 YKM-A & PQRY-P200-300YHM-A units only.

MASTER BC CONTROLLERS
NUMBER OF CONNECTIONS
WEIgHT (kg)
DIMENSIONS (mm)
Width
Depth
Height
ELECTRICAL SUPPLY
PHASE
POWER INPUT (KW)
RUNNINg CURRENT (A)
FUSE RATINg (BS88) HRC (A)
MAINS CABLE No. Cores
BC Box

KS8-CMB-P108V-GA1

KS8-CMB-P1010V-GA1

KS8-CMB-P1013V-GA1

KS8-CMB-P1016V-GA1

KS8-P1016V-HA1

8
43 + 7.9
1110
520 + 280
289
220-240v, 50Hz
Single
0.161
0.68
6
3
CMB-P108V-gA1

10
48 + 9.5
1110
520 + 280
289
220-240v, 50Hz
Single
0.198
0.83
6
3
CMB-P1010V-gA1

13
55 + 12
1110
520 + 280
289
220-240v, 50Hz
Single
0.255
1.07
6
3
CMB-P1013V-gA1

16
62 + 14.5
1110
520 + 280
289
220-240v, 50Hz
Single
0.312
1.30
6
3
CMB-P1016V-gA1

16
69 + 14.5
1110
520 + 280
289
220-240v, 50Hz
Single
0.312
1.30
6
3
CMB-P1016V-HA1

Notes: KS8-CMB-P-V-GA1 units are for use with PURY-P200-650Y(S)JM-A(1), PURY-EP200-650Y(S)KM-A & PQRY-P200-600Y(S)HM-A units only. KS8-CMB-P1016V-HA1 unit is for use with PURY-P700-900YSJM-A & PURY-EP700YSKM-A units only.

SLAVE BC CONTROLLERS
NUMBER OF CONNECTIONS
WEIgHT (kg)
DIMENSIONS (mm)
Width
Depth
Height
ELECTRICAL SUPPLY
PHASE
POWER INPUT (KW)
RUNNINg CURRENT (A)
FUSE RATINg (BS88) HRC (A)
MAINS CABLE No. Cores
BC Box

KS8-CMB-P104V-GB1

KS8-CMB-P108V-GB1

KS8-CMB-P1016V-GB1

4
22 + 4.2
648
432 + 280
284
220-240v, 50Hz
Single
0.076
0.32
6
3
CMB-P104V-gB1

8
32 + 7.5
648
432 + 280
284
220-240v, 50Hz
Single
0.151
0.63
6
3
CMB-P108V-gB1

16
55 + 14.5
1098
432 + 280
284
220-240v, 50Hz
Single
0.301
1.26
6
3
CMB-P1016V-gB1

Product Dimensions

KS8-CMB-P104/105/106V-G1, KS8-CMB-P108/1010/1013/1016V-GA1(HA1), KS8-CMB-P104/108V-GB1, KS8-CMB-P1016HB1

Upper View

Side View

Front View

KS8-CMB-P104V-g1
KS8-CMB-P105V-g1
KS8-CMB-P106V-g1
KS8-CMB-P108V-gA1
KS8-CMB-P1010V-gA1
KS8-CMB-P1013V-gA1
KS8-CMB-P1016V-gA1
KS8-CMB-P1016V-HA1
KS8-CMB-P104V-gB1
KS8-CMB-P108V-gB1
KS8-CMB-P1016V-HB1

Air Conditioning
1.5.95 1.121

432
432
432
520
520
520
520
520
432
432
432

648
648
648
1110
1110
1110
1110
1110
648
648
1098

284
284
284
284
284
284
284
284
284
284
284

4
5
6
8
10
13
16
16
4
8
16

Notes: Product dimensions are for indication of port isolation valves. For detailed BC Controller dimensions see table above

BC Controllers With Port Isolation Valves

1.5.96

PAC-AH-M-J
Air Handling Unit Controller

The Air Handling Unit Controller is an interface to allow connection to third party manufacturer equipment.
Mitsubishi Electric City Multi outdoor units can be used with this interface box, creating an ideal solution when a unique air handling
unit is required. The Air Handling Unit Controllers are supplied with LEV expansion device(s).

Key Features
Return air temperature control
temperature set point by control 0-10VDC
Auto mode available for ease of application
Error input
IP2X rated (only for internal use)
CN105 connector available - connect to A1M for simple BEMS interfacing

MODEL REFERENCE

PAC-AH125M-J

PAC-AH125M-J

PAC-AH140M-J

PAC-AH250M-J

PAC-AH250M-J

PAC-AH500M-J

P100

P125

P140

P200

P250

P400*2

P500*2

10.0 - 12.5

12.5 - 16.0

16.0 - 18.0

18.0 - 25.0

25.0 - 31.5

40.0 - 50.0

50.0 - 63.0

AIR HANDLINg UNIT SIZE


ALLOWED HEAT ExCHANgER CAPACITY (kW) - HEATING

PAC-AH500M-J

ALLOWED HEAT ExCHANgER CAPACITY (kW) - COOLING

9.0 - 11.2

11.2 - 14.0

14.0 - 16.0

16.0 - 22.4

22.4 - 28.0

36.0 - 45.0

45.0 - 56.0

ALLOWED HEAT ExCHANgER VOLUME (cm3)

1500 - 2850

1900 - 3550

2150 - 4050

3000 - 5700

3750 - 7100

6000 - 11400

7500 - 14200

REFERENCE AIR FLOW RATE (m3/h)

2000

2500

3000

4000

5000

8000

10000

STANDARD EVAPORATOR PATH NUMBER*1

4-5

4-5

5-6

6 - 10

8 - 10

16 - 20

16 - 20

DIMENSIONS (mm)

Width

328

328

328

328

328

328

328

( ) = Inc Mountings

Depth

104 (122)

104 (122)

104 (122)

104 (122)

104 (122)

104 (122)

104 (122)

Height

378 (420)

378 (420)

378 (420)

378 (420)

378 (420)

378 (420)

378 (420)

Gas

15.88 (5/8)

15.88 (5/8)

15.88 (5/8)

19.05 (3/4)

22.22 (7/8)

28.58 (1 1/8)

28.58 (1 1/8)

Liquid

9.52 (3/8)

9.52 (3/8)

9.52 (3/8)

9.52 (3/8)

9.52 (3/8)

12.7 (1/2)

15.88 (5/8)

WEIgHT (kg)
PIPE SIZE mm (in)

Example 1

Air Handling Unit Controller


(Mitsubishi Electric)

Controller (field supplied)

APPLICABLE OUtDOOR / CONDENSING UNItS


PUHY-P200-500Y(S)JM-A
PUHY-EP200-500Y(S)KM-A

220-240v, 50Hz
Power Supply

PUHY-HP200-500Y(S)HM-A
PUHY-RP200-500Y(S)JM-B
PQHY-P200-500Y(S)HM-A
PQRY-P200-300Y(S)HM-A

Thermistor wiring

M-NET wiring

Piping

Outdoor Unit (Mitsubishi Electric)

Air Handling Unit (field supplied)

Notes: One air handling unit controller is required per air handling unit. Saturated refrigerant temperature at exit of evaporator = 8.5C, SH = 5K, liquid temperature = 25C, air = 27CDB/19CWB.
*1 When the diameter of the heat exchanger tube is 9.52. *2 P400 and P500 are not compatible with PQRY.

Product Dimensions

PAC-AH-M-J

Front View

Side View
328

10

132

420

27

400

274

Lower View

Air Conditioning
1.5.97 1.121

PAC-AH-M-J

1.5.98

Refrigerant
Detection Systems

The refrigerant detection systems are designed to supply a total refrigerant gas detection package to
detect air conditioning leaks with the option of providing pump down of City Multi VRF R2 systems.
These systems help safeguard against refrigerant levels exceeding permitted concentration levels and react effectively
in the event of leaks.

Key Features
Enables compliance with EN378 Safety of Building Occupants, critical in hotel applications
Can help achieve recognition within BREEAM Pollution Prevention Assessment, ideal for assisting
in the design of modern, sustainable buildings
Robust and tested leak detection with pump down option
Flexible refrigerant gas detection systems - semi-conductor or infra-red, in standalone or cost effective aspirated panel options
Pump down panel incorporating all elements required for safety and environmental protection along with ease of installation
Actuated ball valves to isolate refrigerant on pump down
Alarm system to alert occupants and staff of any leakages
DESCRIPtION

MODEL REF.

Standalone Refrigerant Detectors


White recessed standalone semi-conductor detector

KSGD-01W

Silver recessed back box semi-conductor detector

KSGD-01S

White standalone infra-red detector

KSIR-01

Aspirated Refrigerant Detectors


KSGD-01W

KSGD-01S

8 channel aspirated infra-red detector panel

KS8-IR8C

16 channel aspirated infra-red detector panel

KS8-IR16C

100m drum sampling tube for aspirated panel (black)

KS8-BST100

250m drum sampling tube for aspirated panel (black)

KS8-BST250

Stainless steel room faceplate for aspirated panel

KS8-SSFP

Stainless steel room faceplate with alarm for aspirated panel

KS8-SSFPA

Sampling tube straight connector for aspirated panel

KS8-STSC

Sampling tube two way manifold for aspirated panel

KS8-ST2M

Inline filter for aspirated panel

KS8-IF

End of line filter for aspirated panel

KS8-EF

Accessories
KSIR-01

KS8-IR16C

5 wire adaptor for standalone refrigerant detectors used with pump down

PAC-SA88HA

Room alarm indicator (visual and audible alarm)

KSRA1

Transformer 12VDC

KSTR12

Transformer 24VDC

KSTR24

DESCRIPtION

MODEL REF.

City Multi Pump Down Control Panels


City Multi R2 Automatic Pump Down Control Panel 1 outdoor unit

KS8-OC1

City Multi R2 Automatic Pump Down Control Panel 2 outdoor units

KS8-OC2

City Multi R2 Automatic Pump Down Control Panel 3 outdoor units

KS8-OC3

City Multi R2 Automatic Pump Down Control Panel 4 outdoor units

KS8-OC4

City Multi R2 Automatic Pump Down Control Panel 5 outdoor units

KS8-OC5

City Multi R2 Automatic Pump Down Control Panel 6 outdoor units

KS8-OC6

City Multi R2 Automatic Pump Down Control Panel 7 outdoor units

KS8-OC7

City Multi R2 Automatic Pump Down Control Panel 8 outdoor units

KS8-OC8

Actuated Ball Valves for Pump Down Operation


KS8-OC1

5/8" Actuated ball valve

KS8-5/8 ABV

3/4" Actuated ball valve

KS8-3/4 ABV

7/8" Actuated ball valve

KS8-7/8 ABV

1.1/8" Actuated ball valve

KS8-1.1/8 ABV

1.3/8" Actuated ball valve

KS8-1.3/8 ABV

1.5/8" Actuated ball valve

KS8-1.5/8 ABV

Installation Example City Multi Pump Down System


Pump Down
Control Panel

Refrigerant Detector
Standalone or output
from Aspirated Panel

5-Wire adaptor connected to CN52

KS8-SSFP

Outdoor Unit
Branch Controller

Indoor Unit

Actuated
Ball Valves

MNEt

It is recommended that system design is completed


with your local Mitsubishi Electric Sales Office
Air Conditioning
1.5.99 1.121

Please Note: commissioning is required on pump down systems

Refrigerant Detection Systems

1.5.100

The Energy Efficient

City Multi
VRF Range

Accessories /
Optional Extras

DESCRIPtION

MODEL REF.

Outdoor Units
Branch Pipe (Joint) for size 200 or below - total capacity of indoor units

CMY-Y102SS-G2

Branch Pipe (Joint) for size 201-400 - total capacity of indoor units

CMY-Y102LS-G2

Branch Pipe (Joint) for size 401-650 - total capacity of indoor units or first branch of (E)P450-P650

CMY-Y202S-G2

Branch Pipe (Joint) for size 651 or above - total capacity of indoor units or first branch of P700-P1250 / EP700-EP900

CMY-Y302S-G2

Branch Pipe for 2 branches (PUMY)

CMY-Y62-G-E

Twinning Kit for PUHY-P500-650YSJM-A / PUHY-EP400-600YSKM-A /


PUHY-HP400-500YSHM-A / PQHY-P400-600YSHM-A

CMY-Y100VBK3

Twinning Kit for PUHY-P700-900YSJM-A

CMY-Y200VBK2

Twinning Kit for PUHY-P950-1250YSJM-A / PUHY-EP650-900YSKM-A / PQHY-P650-900YSHM-A

CMY-Y300VBK3

Twinning Kit for PUHY-RP400-650YSJM-B

CMY-RP100VBK

Twinning Kit for PUHY-RP700-900YSJM-B

CMY-RP200VBK

Twinning Kit for PURY-P450-650YSJM-A(1) / PURY-EP400-500YSKM-A

CMY-R100VBK2

Twinning Kit for PURY-P700-800YSJM-A

CMY-R200VBK

Twinning Kit for PURY-EP550-700YSKM-A

CMY-R100XLVBK

Twinning Kit for PURY-P850-900YSJM-A

CMY-R200XLVBK

Twinning Kit for PQRY-P400-600YSHM-A

CMY-Q100VBK

Energy Monitoring Connector

PAC-CN32WHMC-UK

4-Way Blow Cassette Units


grille for PLFY-P-VBM-E

PLP-6BA

grille for PLFY-P-VCM-E

SLP-2AAW

grille and infra-red controller for PLFY-P-VBM-E

PLP-6BALM

grille with filter lowering function for PLFY-P-VBM-E

PLP-6BAJ

i-see Sensor corner panel for PLFY-P-VBM-E

PAC-SA1ME-E

Infra-red signal receiver for PLFY-P-VBM-E

PAR-SA9FA-E

Infra-red Controller for PLFY-P-VBM-E

PAR-SL97A-E

DESCRIPtION

MODEL REF.

1-Way Blow Cassette Units


grille for PMFY-P-VBM-E

PMP-40BMW

Ceiling Concealed Ducted Units


Drain lift-up mechanism for PEFY-P-VMH-E

PAC-KE04DM-F

Long life filter for PEFY-P80VMH-E

PAC-KE88LAF

Long life filter for PEFY-P100-140VMH-E

PAC-KE89LAF

Long life filter for PEFY-P200-250VMHS-E

PAC-KE85LAF

Filter box for PEFY-P80VMH-E (necessary when long life filter is used)

PAC-KE80TB-F

Filter box for PEFY-P100-140VMH-E (necessary when long life filter is used)

PAC-KE140TB-F

Filter box for PEFY-P200-250VMHS-E (necessary when long life filter is used)

PAC-KE250TB-F

BC Controllers
Joint Pipe

CMY-R160-J1

Indoor Units
Remote Sensor

PAC-SE41TS-E

Discreet Remote Temperature Sensor

KS9-BS1

VRF Heat Pump Boilers


Controller

PAR-W21MAA-J

Thermistor (5m cable)

THERM-10M

PFD Stands
Stand for PFD-P250VM-E

KS6-250

Stand for PFD-P500VM-E

KS6-500

Acoustic Kits for PUHY and PURY Series units


A range of Acoustic Kits designed for noise reduction. An industry
first, the kits offer up to 8dBA noise level reduction from standard.
For design, supply and / or installation please contact
Ambient Acoustics on 01934 712802

Note: Colour representation only. Real colour is matched to standard outdoor unit colour.

Air Conditioning
1.5.101 1.121

Accessories / Optional Extras

Heating Only
Heating Only Solutions

The Innovative

Heating Only
Solutions

With legislation changing and increasing pressure to replace traditional


heating systems with renewable sources of heat, the industry needs to
be able to provide a wide range of innovative solutions.
Building on a comprehensive range of heating products, Mr Slim and City Multi Heating Only products offer a cost effective
and efficient solution designed to combat challenging legislation and the need to reduce carbon emissions and running costs.
Designed to deliver heat via the air, our full range of air conditioning products can also be adapted with the use of intelligent
controls to run as Heating Only products.

Why Heating Only


Heat Pumps have been developed over the years to enable heating and cooling from one machine, but there are many reasons
to use these energy efficient products to provide only heating to a building via the delivery method of air.
Many buildings do not need cooling, for example schools and student accommodation
Heat pump air conditioning systems offer a simple, flexible and efficient method of delivering heat to a building
Help with Part L Compliance by removing all power consumption related to cooling

1.6.3

1.121
Air Conditioning

Heating Only

Heating Only Solutions

1.6.4

The Innovative

Heating Only
Solutions

Heating Only Student Accommodation Solution


A 48 bed student accomodation block was modelled using EDSL Tas dynamic building simulation
software*1, built to 2010 Building Regulations.
Natural ventilation via opening windows proved no cooling required
Heating Only, Gas boiler and Direct Electric Heating options analysed - results show the Heating Only products
to be the most efficient solution
Heating Only solution passed Part L and had a 17% lower emission rate than the required target
Heating Only solution provided the best Energy Performance Rating (EPC) for the building

Screenshot from EDSL Tas software of


simulated student accommodation.
Please note this is a fictional building.

Pass Part L?

BER (kg CO2 / m2)

% BER < TER

EPC rating

Heating Only

Yes

36.7

83%

27 (B)

Gas Boiler

Yes

44.7

95%

33 (B)

Direct Electric

No

55.6

104%

41 (B)

Heating Method

BER = Building Emission Rate TER = Target Emission Rate EPC = Energy Performance Certificate
*1 Many Mitsubishi Electric models can now be modelled directly and simply within EDSL Tas software. For more detail please refer to the City Multi section or visit www.edsl.net

The Innovative

Heating Only
Solutions

Contents

1.6.5

1.121
Air Conditioning

Mr Slim Heating Only Solution

1.6.6

City Multi Heating Only Solution

1.6.7

Heating Only

Heating Only Solutions

1.6.6

Mr Slim
Heating Only
Solution

The Mr Slim Power Inverter range (PUHZ-ZRP) from 3.5 to 45kW can be
ordered as a Heating Only solution.
The products have a unique product name, but share the same specifications and price as the standard heating and cooling model.
For full specifications and prices, please see the Mr Slim section, indicated by the key features symbol for Heating Only.
The full indoor unit model range is compatible with the CUHZ Heating Only outdoor units.

HEATING ONLY MODEL

STANDARD MODEL EQUIVALENT

CUHZ-ZRP35VKA

PUHZ-ZRP35VKA

CUHZ-ZRP50VKA

PUHZ-ZRP50VKA

CUHZ-ZRP60VHA

PUHZ-ZRP60VHA

CUHZ-ZRP71VHA

PUHZ-ZRP71VHA

CUHZ-ZRP100VKA

PUHZ-ZRP100VKA

CUHZ-ZRP125VKA

PUHZ-ZRP125VKA

CUHZ-ZRP140VKA

PUHZ-ZRP140VKA

CUHZ-ZRP100YKA

PUHZ-ZRP100YKA

CUHZ-ZRP125YKA

PUHZ-ZRP125YKA

CUHZ-ZRP140YKA

PUHZ-ZRP140YKA

CUHZ-RP200YKA

PUHZ-RP200YKA

CUHZ-RP250YKA

PUHZ-RP250YKA
Note: A PAR-31MAA must be used

City Multi
Heating Only
Solution

The City Multi range from 25-50kW can be ordered as a Heating Only solution.
The products have a unique product name, but share the same specifications and price as the standard heating and cooling models.
For full specifications and prices, please see the City Multi section, indicated by the key features symbol for Heating Only.
The full indoor unit model range is compatible with the CHU/CHQ Heating Only outdoor units.

AIR SOURCE OPTIONS


HEATING ONLY MODEL

STANDARD MODEL EQUIVALENT

CHU-P200YJM

PUHY-P200YJM

CHU-P250YJM

PUHY-P250YJM

CHU-P300YJM

PUHY-P300YJM

CHU-P350YJM

PUHY-P350YJM

CHU-P400YJM

PUHY-P400YJM

CHU-P450YJM

PUHY-P450YJM

WATER SOURCE OPTIONS


HEATING ONLY MODEL

1.6.7

1.121
Air Conditioning

STANDARD MODEL EQUIVALENT

CHQ-P250YHM

PQHY-P250YHM

CHQ-P300YHM

PQHY-P300YHM

Heating Only

Mr Slim / City Multi Heating Only Solutions

Heating

Heating

Increasing energy bills, the need to reduce carbon emissions and the raft
of challenging legislation are driving the demand for alternative forms of
heating to improve energy efficiency.
As a market leader in both commercial and domestic renewable solutions, Mitsubishi Electric is a pioneer in the development
of renewable heat pump technology. Heat pumps have been used around the world for decades and Mitsubishi Electric has refined
this technology to produce Ecodan - one of the most advanced, efficient heating systems available today.
The award winning Ecodan heat pump range is suitable for both small and large projects and delivers effective, low carbon heating and
hot water. Ecodan systems provide a simple, renewable solution that rivals traditional heating systems.

Helps achieve renewable energy targets


Capable of reducing running costs and CO2 emissions
Easy to design, install and maintain
Fully scalable and can work independently or in conjunction with other systems
Optimised systems from 4kW to 688kW
MCS approved
From small flats to large detached houses, office blocks, schools and community heating schemes, Ecodan is the ideal choice
to provide reliable space heating and hot water all year round.

MELCloud is a new Cloud based solution for


controlling your Mitsubishi Electric Ecodan systems
either locally or remotely by PC, Mac, Tablet or
Smartphone via the Internet.

2.3

1.121 Heating

Renewable Heating Systems

2.4

How Ecodan air source heat pumps work


Ecodan heat pumps require only a small amount of electricity to harvest, upgrade and move heat from
one location to another.
To achieve this a vapour compression cycle is used, which has the ability to take low temperature
renewable heat from the environment and raise it to usable temperatures capable of handling the space
and water heating loads required in buildings.
The vapour compression cycle

At the beginning of the first phase the refrigerant


is a cold low pressure liquid
1. The refrigerant passes into the evaporator and heat energy from the
outside air passes over the evaporator causing the refrigerant to
increase in pressure and change to a warm vapour.

2.2kW

2. This warm vapour then enters the compressor where its temperature
increases as a result of the compression process and turns into a hot gas.
3. The hot refrigerant gas is then condensed as it passes across one
side of a plate heat exchanger. The heat is transferred to the
cooler side (water side) of the heat exchanger, and this is transferred
via the primary water circuit to heat up the water tank inside
the property. As the temperature of the refrigerant decreases the
state changes from a gas back to a cool vapour.

3.2kW

4. Despite dropping in temperature, the cool vapour still has a high


pressure and to reduce this pressure the vapour passes through an
expansion valve. This causes the pressure to drop and the temperature
lowers, returning the refrigerant to its initial state of cool low pressure liquid.

This process is repeated


*As independently tested by BSRIA based upon BSEN14511 Part 3 standard rating conditions.
Due to the method of operation, the performance of heat pumps will vary based upon the
temperature of the heat source and the requirements of the heat delivered. The BSEN14511
testing relates to the heat pump performance only and not the entire heating system.

It is only the refrigerant that passes through this cycle; the water is heated as it travels through the plate heat exchanger. The heat energy
from the refrigerant passes through the plate heat exchanger to the cooler water which increases in temperature. This heated water
enters the building heating circuit and can also be used to provide sanitary hot water via a hot water cylinder.

Microgeneration Certification Scheme


The complete range of Ecodan heating products has received full accreditation for the Governments
Microgeneration Certification Scheme (MCS).
The MCS process is very robust and also looks at the companies installing this type of equipment so that customers
can take real confidence that they will get the reduction in fuel consumption expected. MCS is administered by
the DECC (the Department for Energy & Climate Change) and is designed to evaluate products and installers
against criteria for microgeneration technologies, thereby providing greater consumer protection. An MCS approved
product, such as Ecodan, installed by an MCS approved installer is a requirement to apply for the Governments
Renewable Heat Incentive (RHI).

SAP Appendix Q
SAP Appendix Q allows you to enter performance data specific to Ecodan rather than using the default Air Source Heat Pump (ASHP) data in
SAP. SAP Appendix Q generates a saving in kWh/year rather than a set COP. This saving can then be retrospectively applied to SAP 2005.
Savings will vary due to differences in heat loads and hot water demands from each property. Feedback from those who have already used
the data have reported significant benefits.

EU Ecolabel
The EU Ecolabel also known as the Flower due to its flower logo denotes products and services with superior
environmental performance. Products bearing the label are certified to meet EU-wide environmental criteria, and
compliance is independently verified by an approved body. The EU Ecolabel scheme is voluntary and represents products
with class leading environmental performance. It is available for many consumer and commercial product groups and
now includes heat pumps. The Ecodan Monobloc PUHZ range of products met this criteria in November 2009.

Quiet Mark
The Ecodan range is the first air source heat pump to receive the official backing of the Noise Abatement Society
which has awarded it the new Quiet Mark of approval.

Enhanced Capital Allowance


Some of our Ecodan products are registered on the Energy Technology List and hence qualify
for enhanced capital allowances. For further information please go to etl.decc.gov.uk/etl
Products eligible include Ecodan PUHZ-(H)W and Ecodan CAHV.

2.5

1.121 Heating

Renewable Heating Systems

2.6

Ecodan Sales Tools


Home Owner Portal
The Homeowner Portal was developed to increase understanding amongst homeowners on
how to get the best out of their Ecodan heating system, and uses clever animations to show
how to operate the systems controller.
Offering guidance through video tutorials, the Homeowner Portal is a useful tool for installers
when demonstrating how Ecodan works, as it provides easy access to simple but detailed
information on how to operate, programme and manage the system. The site also includes
a very useful FAQ section which has been designed to sell the concept of air source heat pumps
and increase the understanding of why Mitsubishi Electrics Ecodan leads the market.
Please visit the website: homeownerportal.mitsubishielectric.co.uk

Ecodan Selection Tool


The brand new Ecodan Selection Tool allows end users, consultants, contractors or anyone else with an interest in heat pumps to get an
insight into what this technology could deliver to your building. Whether your project is a single domestic dwelling or a large commercial
project, the application is designed to direct you towards the right solution, whilst personalising the information for you.
So for example, as a homeowner we have chosen to supply you with case studies and application information, but
for a contractor you would want to know more technical information about the heat pump itself. The aim of the tool
is to deliver a personalised bespoke equipment selection for your project; allowing you to make a decision about
progressing to the next stage of design.
Please visit the website: ecodanselectiontool.heating.mitsubishielectric.co.uk

Ecodan Dashboard
The Ecodan Dashboard demonstrates the effectiveness of Ecodan air source heat pumps by showing real data gathered from properties
around the country that are using the Ecodan system.
For each monitored site, the dashboard gives an overview of the system, detailing age and type of property. You can also determine how
the unit performs at any time of the day, week, month or year and see the running costs, CO2 emissions and energy consumed, when
compared to gas, oil and direct electric systems. The dashboard is designed to be as open and transparent as possible so that owners
can see the results for themselves, whether it is in the height of summer or the depths of winter.
Please visit the website: dashboard.mitsubishielectric.co.uk

Ecodan PUHZ-(H)W Monobloc Air Source Heat Pumps

2.8

Ecodan CAHV Monobloc Air Source Heat Pump

2.10

Ecodan CRHV Monobloc Ground / Water Source Heat Pump

1.12

Ecodan EHPT20X-VM2HB Packaged Cylinder For Ecodan Monobloc Units

2.14

Ecodan ECOSLIM-150L-180L-PP-MEUK Pre-plumbed Slimline Cylinder For Ecodan Monobloc Units

2.16

Ecodan HU150-300FTC4ST Pre-plumbed Standard Cylinder For Ecodan Monobloc Units

2.18

Ecodan HUS210-300FTC4ST Pre-plumbed Solar Cylinder For Ecodan Monobloc Units

2.20

Ecodan EHPX-VM2B Packaged Hydrobox For Ecodan Monobloc Units

2.22

Optimised Rotary or Sroll Compressor

Ecodan PUHZ-SW Split Air Source Heat Pumps

2.24

Inverter Control - adjusts performance to economically


match the demand for heating or cooling

Ecodan EHSC-VM2B Split Hydrobox For Ecodan Split Units

2.26

Auto-Restart

MELCloud for Ecodan

2.28

Quiet Operation

Ecodan Prices

2.30

Wi-Fi

Ecodan Accessories

2.35

Contents
Features Key

Blue Fin Treatment - protection from


corrosion in high salt environments
SD Card Commissioning and Logging

Magnetic Filter
Optimised Cascade Function
Intelligent Bivalent / Hybrid Operation

Intelligent Defrost - reverse cycle


using dual refrigerant circuits
WHR

Waste Heat Recovery


Weather Compensation

2.7

1.121 Heating

Contents

2.8

Our range of Ecodan monobloc air source heat pumps includes 5, 8.5 and 14kW sizes.

PUHZ-(H)W

Monobloc Air Source


Heat Pumps

Now with the ability to cascade up to six units of the same output, Ecodan monobloc systems offer a capacity range
from 5 through to 84kW. Designed to suit a wide number of applications, these models offer a viable solution for the
varying requirements that domestic and small commercial applications demand.

Key Features

Self-contained unit, only requiring water and electric connections


No need for gas supply, flues or ventilation
Single phase power supply with a low starting current (3 phase available for 14kW)
Low maintenance and quiet to run
Operates with outside temperatures as low as -25C
Multiple unit connection
Bivalent function, for use with conventional boilers
2-zone energy efficient space heating control
Available as a standalone, packaged or semi packaged system
Remote Wi-Fi control with MELCloud

PUHZ-W85VHA2

MODEL
Heating*1
(A-3/W35)

Capacity (kW)
Power Input (kW)
COP
Heating*2
Capacity (kW)
(A2/W35)
Power Input (kW)
COP
Heating*3
Capacity (kW)
(A7/W35)
Power Input (kW)
COP
Operating Ambient Temperature (C DB)
Sound Pressure Level at 1m (dBA)*3*4
Low Noise Mode (dBA)*3
Water Data
Pipework Size (mm)
Flow Rate (l/min)
Water Pressure Drop (kPa)
Dimensions (mm)*7
Width
Depth
Height
Weight (kg)
Electrical Data
Electrical Supply
Phase
Nominal Running Current [MAX] (A)
Fuse Rating - MCB Sizes (A)*6

Certificate Number: MCS HP0002


Product Reference:
PUHZ-W50VHA-(BS), PUHZ-W85VHA2-(BS)
PUHZ-HW140VHA2/YHA2-(BS)

Licence Number:
UK/31/001 - PUHZ-W50VHA-(BS)
UK/31/002 - PUHZ-W85VHA2-(BS)
UK/31/003 - PUHZ-HW140VHA2/YHA2-(BS)

PUHZ-W50VHA
4.8
1.63
2.95
5.0
1.60
3.13
5.0
1.22
4.10
-15 ~ +35C
45
40
22
14.3
12
950
330+30*5
740
64
220-240v, 50Hz
Single
5.4 [13]
16

PUHZ-W85VHA2

8.3
2.96
2.80
8.5
2.68
3.17
9.0
2.15
4.18
-20 ~ +35C
48
42
22
25.8
13.5
950
330+30*5
943
77
220-240v, 50Hz
Single
10.3 [23]
25

*1 Under normal heating conditions at outdoor temp: -3CDB / -4CWB, outlet water temp 35C, inlet water temp 30C
*2 Under normal heating conditions at outdoor temp: 2CDB / 1CWB, outlet water temp 35C, inlet water temp 30C as tested to BS EN14511
*3 Under normal heating conditions at outdoor temp: 7CDB / 6CWB, outlet water temp 35C, inlet water temp 30C as tested to BS EN14511
*4 Sound power level of the PUHZ-W50VHA is 61dBA, PUHZ-W85VHA2 is 62.5dBA, PUHZ-HW140VHA2 is 65.5dBA, PUHZ-HW140YHA2 is 67.5dBA. Tested to BS EN12102
*5 Grille
*6 MCB Sizes BS EN60898-2 & BS EN60947-2
*7 Flow Temperature Controller (FTC) for standalone systems, PAC-IF052B-E, Dimensions WxDxH (mm) - 393x87x422

PUHZ-HW140VHA2
14.0
4.81
2.91
14.0
4.52
3.11
14.0
3.31
4.25
-25 ~ +35C
53
46
28
40.1
9
1020
330+30*5
1350
134
220-240v, 50Hz
Single
14.9 [35]
40

PUHZ-HW140YHA2
14.0
4.81
2.91
14.0
4.52
3.11
14.0
3.31
4.25
-25 ~ +35C
53
46
28
40.1
9
1020
330+30*5
1350
148
380-415v, 50Hz
3
5.1 [13]
16

Product Dimensions

2.9

PUHZ-W50VHA

Product Dimensions

PUHZ-W85VHA2

Product Dimensions

Upper View

Upper View

Upper View

Front View

Front View

Front View

1.121 Heating

PUHZ-HW140VHA2 / YHA2

PUHZ-(H)W Monobloc Air Source Heat Pumps

2.10

CAHV

Monobloc Air Source


Heat Pump

Specifically designed for large applications, the Ecodan CAHV air source heat pump monobloc system can
operate singularly, or form part of a multiple unit system. The CAHV also comes equipped with a wide range
of controller features as standard.
A multiple unit system has the ability to cascade available units on and off to meet the load from a building. As an example of this modulation,
a 16 unit system allows 0.5kW increments of capacity, from 18kW all the way up to 688kW. This level of modulation is unprecedented
within the heating industry and with cascade and rotation built in as standard, the Ecodan CAHV system is perfectly suited to a wide
range of commercial applications.

Key Features

Multiple unit cascade control of up to 688kW capacity


Split refrigerant circuits within each CAHV provide 50% back up
Ability to rotate units based on accumulated run hours
Provides from 25C up to 70C water flow temperatures without boost heaters
Low maintenance, hermetically-sealed monobloc design
Low on-site refrigerant volume
HIC (Zubadan) technology delivers 43kW at -3C with minimal drop off down to -20C

MODEL
Heating*1

Capacity (kW)
(A-3/W35)
Power Input (kW)
COP
Capacity (kW)
Heating*2
(A2/W35)
Power Input (kW)
COP
Capacity (kW)
Heating*3
(A7/W35)
Power Input (kW)
COP
Operating Ambient Temperature (C DB)
Sound Pressure Level at 1m (dBA)*3*4
Low Noise Mode (dBA)*3
Flow Rate (l/min)
Water Pressure Drop (kPa)
Dimensions (mm)
Width
Depth
Height
Weight (kg)
Electrical Supply
Phase
Nominal Running Current [MAX] (A)
Fuse Rating - MCB Sizes (A)*5

Certificate Number: MCS HP0002


Product Reference: CAHV-P500YA-HPB

*1 Under normal heating conditions at outdoor temp: -3CDB / -4CWB, outlet water temp 35C, inlet water temp 30C
*2 Under normal heating conditions at outdoor temp: 2CDB / 1CWB, outlet water temp 35C, inlet water temp 30C
*3 Under normal heating conditions at outdoor temp: 7CDB / 6CWB, outlet water temp 35C, inlet water temp 30C as tested to BS EN14511
*4 Sound power level of the CAHV-P500YA-HPB is 70.7dBA. Tested to BS EN12102
*5 MCB Sizes BS EN60898-2 & BS EN60947-2

CAHV-P500YA-HPB
42.6
15.2
2.80
42.8
14.2
3.01
45.0
10.9
4.13
-20~+40C
59
Variable
126
18
1978
759
1710 (1650 without legs)
526
380-415v, 50Hz
3
17.6 [52.9]
63

Product Dimensions

CAHV-P500YA-HPB

Upper View

Front View

2.11

1.121 Heating

Side View

CAHV Monobloc Air Source Heat Pump

2.12

The new inverter driven Ecodan CRHV monobloc ground / water source heat pump can operate singularly, or be banked
together to create a system that can modulate and cascade available units on and off to meet the load from a building.

CRHV

Monobloc Ground / Water


Source Heat Pump

This level of modulation is unprecedented within the heating industry and with cascade and rotation built in as standard, the Ecodan
CRHV system is perfectly suited to a wide range of commercial applications.

Key Features

Bore holes, slinkies, aquifers, lakes, rivers, waste heat can all be used as a heat source
Multiple unit cascade control of up to 16 units
Split refrigerant circuits within each CRHV provide 50% back up
Ability to rotate units based on accumulated run hours
Provides up to 65C water flow temperatures without booster heaters
Low maintenance, low refrigerant volume hermetically-sealed monobloc design

Heat recovery applications can be achieved by moving heat


between applications
Passive cooling possible by exchanging ground / water source
with a chilled water system
Low pressure drop to ensure pumping power is kept to a minimum
High specification touch screen controls interfacing with BEMS

WHR

CRHV-P600YA-HPB

MODEL
Heating*1
(B0/W35)
Seasonal Efficiency EN14825 (SPF)
Heating*2
(B0/W35)
Seasonal Efficiency EN14825 (SPF)
Heating*3
(W10/W35)
Seasonal Efficiency EN14825 (SPF)
Heating*4
(W10/W35)
Seasonal Efficiency EN14825 (SPF)
Sound Data
Water Data

Flow Rate Range


Mechanical Connections

Operating Temperature Range

PLEASE NOTE: Full design criteria is needed to ascertain the capacity which could
change based on heat source temperature and building flow temperature.
*1 Under normal heating conditions at brine inlet: 0C, outlet water temp 35C as tested
to BS EN14511 (60kW)
*2 Under normal heating conditions at brine inlet: 0C, outlet water temp 35C as tested
to BS EN14511 (45kW)
*3 Under normal heating conditions at water inlet: 10C, outlet water temp 35C as tested
to BS EN14511 (60kW)
*4 Under normal heating conditions at water inlet: 10C, outlet water temp 35C as tested
to BS EN14511 (45kW)
*5 Sound power level as tested to BS EN12102
*6 Heat source inlet temperature above 27C and up to 45C option must reverse the inlet
and outlet heat source connections and refer to manual for dip switch changes
*7 The system should be adequately protected from freezing
*8 MCB Sizes BS EN60898-2 & BS EN60947-2
* LTHW - Low Temperature Hot Water
* Please don't use steel for the water piping material
* Please use adequate frost protection to ensure pipework and the unit do not freeze
if the system is powered down
* Please do not use ground water or well water directly within the unit
* The water circuit must be a closed circuit

Heat Source Fluid Type *7


Pressure Drop
(at 1.5l/s inc 30% glycol in heat source fluid)
Maximum Working Pressure
Dimensions

Weight (kg)
Refrigerant

Electrical Data

Capacity (kW)
Power Input inc. pump (kW)
COP
B0/W35 (60kW)
Capacity (kW)
Power Input inc. pump (kW)
COP
B0/W35 (45kW)
Capacity (kW)
Power Input inc. pump (kW)
COP
W10/W35 (60kW)
Capacity (kW)
Power Input inc. pump (kW)
COP
W10/W35 (45kW)
Pressure Level Lpa at 1m (dBA)
Power Level Lwa (dBA) *5
Heat Source (Brine) (l/s (m3/hr))
Building Side (LTHW) (l/s (m3/hr))
Heat Source Outlet (Brine) (mm ("))
Heat Source Inlet (Brine) (mm ("))
Building Side Outlet (LTHW) (mm ("))
Building Side Inlet (LTHW) (mm ("))
Heat Source Inlet (Brine) (C)
Heat Source Inlet Option (Brine) (C) *6
Building Side Outlet (LTHW) (C)
Heat Source (Brine) (kPa)
Building Side (LTHW) (kPa)
Heat Source (Brine) (MPa(Bar))
Building Side (LTHW) (MPa(Bar))
Width (mm)
Depth (mm)
Height (mm)
Type
Charge (kg)
Max pressure (MPa (Bar))
Compressor Type
Circuit Type
Electrical Supply
Phase
Maximum Running Current (A)
Fuse Rating - MCB Size (A) *8

60
14.20
4.23
4.33
45
10.20
4.41
4.00
60
11.90
5.08
5.09
45
8.89
5.11
4.55
50
66
1.5 to 4.1 (5.4 to 15)
1.5 to 4.4 (5.4 to 16)
50.8 (R2) screw
50.8 (R2) screw
50.8 (R2) screw
50.8 (R2) screw
-8 to +27
-8 to +45
+30 to +65
Min 30% Ethylene Glycol or equivalent
12
7
1 (10)
1 (10)
934
780
1561
395
R410A
4.5 x 2
4.15 (41.5)
Inverter Driven
Hermetically Sealed System
415v, 50Hz
3 Phase
44
50

Product Dimensions

CRHV-P600YA-HPB

Side View

Front View

HOT WATER OUTLET


R2B

934

HOT WATER OUTLET


R2B

HOT WATER INLET

773

R2B

HEAT SOURCE WATER INLET


R2B

1561

1561

HOT WATER INLET


R2B

HEAT SOURCE WATER INLET

110

HEAT SOURCE WATER OUTLET

HEAT SOURCE WATER OUTLET


R2B

R2B

R2B

85
(60)

170
69

2.13

1.121 Heating

590

(170)
(69)

660

(23.5)

60
23.5

(780)

CRHV Monobloc Ground / Water Source Heat Pump

2.14

The packaged cylinder unit is the latest generation hot water tank, with integrated hydraulic components
and advanced controls.

EHPT20X-VM2HB
Packaged Cylinder for
Ecodan Monobloc Units

Designed specifically by Mitsubishi Electric to integrate with the Ecodan monobloc air source heat pump range, the packaged cylinder
unit provides improved performance with a simple to use graphical interface controller. Fast on site commissioning is now available
via a pre-programmed SD card.

Key Features

Simple graphical control


Capability to provide 2-zone energy efficient space heating control
Sleek modern design
Compatible with Mitsubishi Electric wireless room controllers
Back up electrical heaters
Pre-plumbed and wired for faster installation
Bivalent function, for use with conventional boilers
SD card commissioning
Cascade function for multiple unit control
Remote Wi-Fi control with MELCloud

FTC4 Controller
Mitsubishi Electrics fourth-generation
controller includes intelligent, room
temperature control as standard.
This together with advanced weather
compensation ensures the system
delivers efficient, comfortable heating
regardless of the season.

MODEL

EHPT20X-VM2HB

Nominal Hot Water Volume (Litres)


Operating Ambient Temperature (C DB)
Sound Pressure Level at 1m (dBA)
Water Data

Water Safety Devices

Water Circuit
Booster Heater
DHW Tank

Dimensions (mm)
Weight Empty / Full (kg)
Electrical Data

Control Board optionally powered


by outdoor unit
Immersion Heater

Booster Heater optionally powered


if required

Optional Simplified Wireless Room Thermostat and Wireless Receiver


*1 MCB Sizes BS EN60898-2 & BS EN60947-2

Flow Rate (l/min) W50 - W85 - HW140


Pump
Connection Size (mm) Heating / DHW
Primary Expansion Vessel (Litres)
Charge Pressure (MPa (Bar))
Control Thermistor (C)
Pressure Relief Valve (MPa (Bar))
Flow Switch
Booster Heater Control Thermistor (C)
Booster Heater Manual Reset Thermostat (C)
Booster Heater Thermal Cut Off (C)
Control Thermistor (C)
Temp and Pressure Relief Valve (C)/ (MPa (Bar))
Width
Depth
Height
Electrical Supply
Phase
Fuse Rating - MCB Sizes (A)*1
Electrical Supply
Phase
Capacity (kW)
Max Running Current (A)
Fuse Rating - MCB Sizes (A)*1
Electrical Supply
Phase
Capacity (kW)
Max Running Current (A)
Fuse Rating - MCB Sizes (A)*1

200
0 ~ +35C (RH<80%)
28
14.3 - 25.8 - 40.1
Grundfos UPM2 25 70-180
28 / 22
12
0.1 (1)
1 - 80
0.3 (3)
Supplied
80
90
121
40-70
90 / 0.7 (7)
680
595
1600
113 / 326
220-240v, 50Hz
Single
10
220-240v, 50Hz
Single
3
13
16
220-240v, 50Hz
Single
2
9
16

PAR-WT50-E Controller and PAR-WR51-E Receiver

Front View

Top View

Right View

D
E

47.1
0

Left View

EHPT20X-VM2HB

550.2
541.1
522.8
492.2
470.8

Product Dimensions

0
63.3
67.8
123

A
B

G/J

F
449.7
491.1
509.7
561.7
H/K
L

2.15

1.121 Heating

Letter

Pipe Description

Connection

A
B
C/D
E
F
G
H
L

DHW outlet
Cold water inlet
Solar (ancillary heat source)
Space heating RTN
Space heating flow
Flow from H/P
RTN to H/P
Electrical cable inlets

22mm/Compression
22mm/Compression
22mm/Compression
28mm/Compression
28mm/Compression
28mm/Compression
28mm/Compression

EHPT20X-VM2HB Packaged Cylinder for Ecodan Monobloc Units

2.16

The optimised pre-plumbed slimline cylinder comes complete with integrated hydraulic components
and advanced controls.

ECOSLIM150-180L-PP-MEUK
Pre-plumbed Slimline Cylinder
for Ecodan Monobloc Units

Designed to minimise floor space and footprint whilst still offering optimum performance, the cylinder completely integrates with the
Ecodan monobloc air source heat pump range. The pre-plumbed slimline cylinder unit provides improved performance with a simple
to use graphical interface controller. Fast on site commissioning is now available via a pre-programmed SD card.

Key Features

Simple graphical control


Optional 2-zone energy efficient space heating control
Compatible with Mitsubishi Electric wireless room controllers
Pre-plumbed and wired for faster installation
Factory fitted magnetic filtration system
Hybrid function, for use with conventional boilers
SD card commissioning
Remote Wi-Fi control with MELCloud

MODEL

Water Circuit

DHW Tank

Dimensions (mm)

Weight Empty / Full (kg)


Cylinder Material
Tank
Insulation

Electrical Data

Mitsubishi Electrics fourth-generation


controller includes intelligent, room
temperature control as standard.
This together with advanced weather
compensation ensures the system
delivers efficient, comfortable heating
regardless of the season.

ECOSLIM-150L-PP-MEUK

Nominal Hot Water Volume (Litres)


Water

Water Safety Devices

FTC4 Controller

Control Board
optionally
powered by
outdoor unit

Immersion
Heater

Flow Rate (l/min) W50 - W85


Pump
Connection Size (mm) Heating / DHW (mm)
Primary Expansion Vessel (Litres)
Charge Pressure (MPa (Bar))
Control Thermistor (C)
Pressure Relief Valve (MPa (Bar))
Expansion Relief Valve (Cold)
Control Thermistor
High Limit Stat (C)
Temp and Pressure Relief Valve (C) / (MPa (Bar))
Width
Depth
Height
Cylinder Material
Heating Surface Area (m2)
Insulation Type

Insulation Thickness (mm)


Standing Heat Loss (kWh/24hrs)
GWP of Insulation
ODP of Insulation
Electrical Supply
Phase
Fuse Rating - MCB Sizes (A)*1
Electrical Supply
Phase
Capacity (kW)
Max Running Current (A)
Fuse Rating - MCB Sizes (A)*1

Mechanical Zones
Optional Simplified Wireless Room Thermostat and Wireless Receiver
*1 MCB Sizes BS EN60898-2 & BS EN60947-2

*2 Optional 2-zone accessory available

ECOSLIM-180L-PP-MEUK

150
14.3 - 25.8
1 x Grundfos UPS2 25-60
22
12
0.3 (3)
1 - 80
0.3 (3)
0.6 (6)
40-70
Mechanical 80
90 / 0.7 (7)
475
565
1880

180
14.3 - 25.8
1 x Grundfos UPS2 25-60
22
19
0.3 (3)
1 - 80
0.3 (3)
0.6 (6)
40-70
Mechanical 80
90 / 0.7 (7)
475
565
1950
65.5 / 215.5 69.5 / 249.5
Stainless Steel
Stainless Steel
2
3
Polyurethane (PU) Insulation with CO2 Blowing Agent

50
50
1.31
1.6
0
0
Less than 5
Less than 5
220-240v, 50Hz
220-240v, 50Hz
Single
Single
10
10
220-240v, 50Hz
220-240v, 50Hz
Single
Single
3
3
13
13
16
16
DHW and 1 Heating Zone *2
DHW and 1 Heating Zone *2
PAR-WT50-E Controller and PAR-WR51-E Receiver

Product Dimensions

ECOSLIM-150-180L-PP-MEUK

Front View

Top of AAV (Highest point)


Mains Cold Feed and Heat Pump Flow

C Hot Water Outlet


D Tundish Outlet

Heating Zone 1 Flow


Heating Zone 2 Flow

G Domestic Hot Water Drain


H Heating Zone 1 Return
I

Heating Zone 2 Return

Balanced Cold Feed

Automatic Bypass Valve

MODEL

2.17

1.121 Heating

150L-PP-MEUK

1880

1780

1740

1360

940

860

80

487

730

1100

1800

180L-PP-MEUK

1950

1850

1810

1360

940

860

80

487

730

1100

1870

ECOSLIM-150-180L-PP-MEUK
Pre-plumbed Slimline Cylinder for Ecodan Monobloc Units

2.18

The optimised pre-plumbed standard cylinder comes complete with integrated hydraulic components
and advanced controls.

HU150-300FTC4ST

Pre-plumbed Standard Cylinder


for Ecodan Monobloc Units

Designed to integrate with the Ecodan monobloc air source heat pump range, the pre-plumbed standard cylinder unit provides improved
performance with a simple to use graphical interface controller. Fast on site commissioning is now available via a pre-programmed SD card.

Key Features

FTC4 Controller

Simple graphical control


2-zone energy efficient space heating control
Compatible with Mitsubishi Electric wireless room controllers
Pre-plumbed and wired for faster installation
Factory fitted Fernox TF1 filtration system
Bivalent function, for use with conventional boilers
SD card commissioning
Cascade function for multiple unit control

Mitsubishi Electrics fourth-generation


controller includes intelligent, room
temperature control as standard.
This together with advanced weather
compensation ensures the system
delivers efficient, comfortable heating
regardless of the season.

Remote Wi-Fi control with MELCloud

MODEL

HU150FTC4ST

HU180FTC4ST

HU210FTC4ST

HU250FTC4ST

HU300FTC4ST

Nominal Domestic Hot Water Storage Volume (Litres)

150

180

210

250

300

Overall Cylinder Dimensions (mm)*

Width

550

550

550

550

550

Depth

550

550

550

550

550

Height

1281

1281

1469

1719

2032
113

87.4

92.8

97.7

103.2

Nominal Volume (Litres)

12

19

19

19

24

Charge Pressure (Bar)

3.0

3.0

3.0

3.0

3.0

Mains Inlet Pressure Regulator (Bar)

3.0

3.0

3.0

3.0

3.0

Expansion Relief Valve (CW) (Bar)

6.0

6.0

6.0

6.0

6.0

7.0 / 90

7.0 / 90

7.0 / 90

7.0 / 90

7.0 / 90

Empty Cylinder Weight (kg)


Unvented Store Expansion Vessel
Control / Relief Valve Pressure Settings

P & T Valve (Bar / C)


Backup Immersion Heater Rating (kW)

Insulation Thickness (mm)

50

50

50

50

50

Ozone Depletion Potential

Global Warming Potential

<5

<5

<5

<5

<5

DHW Circuit Zone Valve (mm)

22 (1no.)

22 (1no.)

22 (1no.)

22 (1no.)

22 (1no.)

CH Circuit Zone Valve (mm)

22 (1no.)

22 (1no.)

22 (1no.)

22 (1no.)

22 (1no.)

65

65

65

65

65

230-240v, 50Hz

230-240v, 50Hz

230-240v, 50Hz

230-240v, 50Hz

230-240v, 50Hz

Heat Pump Circuit Circulating Pump

Control & Overheat Safety Thermostat


Temperature Settings

UPS2 25-60 130 (2no.)

Control Stat (C)


Voltage, Hertz

Number of Zones
Optional Simplified Wireless Room Thermostat and Wireless Receiver
*Minimum cupboard footprint 750x750mm

PAR-WT50-E Controller and PAR-WR51-E Receiver

Product Dimensions

HU150-300FTC4ST

Front View

A
B
C
D
E
F
G
H
I
J

D C B

Hot Water Outlet


Cold Mains Inlet
Balanced Outlet
Heat Pump Flow
Tundish Outlet
Automatic Bypass Valve
Heating Zone Valve 1
Heating Zone Valve 2
Heating Return
Heat Pump Return

Model
A
B
C
D
E
F
G
H
I
J

HU150FTC4ST
1290
921
869
1176
417
824
N/A
407
66
136

HU180FTC4ST
1291
937
885
1176
605
824
542
407
66
136

HU210FTC4ST
1479
1363
1311
1176
1031
824
542
407
66
136

HU250FTC4ST
1729
1363
1311
1176
1043
824
542
407
66
136

HU300FTC4ST
2042
1688
1636
1176
1356
824
542
407
66
136

For further information please refer to the installation manual

2.19

1.121 Heating

H G

HU150-300FTC4ST
Pre-plumbed Standard Cylinder for Ecodan Monobloc Units

2.20

The optimised pre-plumbed solar cylinder comes complete with integrated hydraulic components
and advanced controls.

HUS150-300FTC4ST
Pre-plumbed Solar Cylinder
for Ecodan Monobloc Units

Designed to integrate with the Ecodan monobloc air source heat pump range, the pre-plumbed solar cylinder unit provides improved
performance with a simple to use graphical interface controller. Fast on site commissioning is now available via a pre-programmed SD card.

Key Features

Includes secondary coil for connection to solar thermal systems


Simple graphical control
2-zone energy efficient space heating control
Compatible with Mitsubishi Electric wireless room controllers
Pre-plumbed and wired for faster installation
Factory fitted Fernox TF1 filtration system
Bivalent function, for use with conventional boilers
SD card commissioning
Cascade function for multiple unit control
Remote Wi-Fi control with MELCloud

MODEL

FTC4 Controller
Mitsubishi Electrics fourth-generation
controller includes intelligent, room
temperature control as standard.
This together with advanced weather
compensation ensures the system
delivers efficient, comfortable heating
regardless of the season.

HUS210FTC4ST

HUS250FTC4ST

HUS300FTC4ST

Nominal Domestic Hot Water Storage Volume (Litres)

210

250

300

Overall Cylinder Dimensions (mm)*

Width

550

550

Depth

550

550

Height

1719

1719

Empty Cylinder Weight (kg)


Unvented Store Expansion Vessel
Control / Relief Valve Pressure Settings

102.2

108.6

Nominal Volume (Litres)

19

19

Charge Pressure (Bar)

3.0

3.0

Mains Inlet Pressure Regulator (Bar)

3.0

3.0

Expansion Relief Valve (CW) (Bar)

6.0

6.0

7.0 / 90

7.0 / 90

P & T Valve (Bar / C)


Backup Immersion Heater Rating (kW)

Insulation Thickness (mm)

50

50

Ozone Depletion Potential

Global Warming Potential

<5

<5

DHW Circuit Zone Valve (mm)

22 (1no.)

22 (1no.)

CH Circuit Zone Valve (mm)

22 (1no.)

22 (1no.)

65

65

230-240v, 50Hz

230-240v, 50Hz

Control Stat (C)


Voltage, Hertz

Optional Simplified Wireless Room Thermostat and Wireless Receiver


*Minimum cupboard footprint 750x750mm

550
2032
122.2
24
3.0
3.0
6.0
7.0 / 90
3
50
0
<5

UPS2 25-60 130 (2no.)

Heat Pump Circuit Circulating Pump

Control & Overheat Safety Thermostat


Temperature Settings

550

22 (1no.)
22 (1no.)
65
230-240v, 50Hz

PAR-WT50-E Controller and PAR-WR51-E Receiver

Product Dimensions

HUS210-300FTC4ST

Front View

A
B
C
D
E
F
G
H
I
J
K

Hot Water Outlet


Cold Mains Inlet
Balanced Outlet
Heat Pump Flow
Tundish Outlet
Automatic Bypass Valve
Heating Zone Valve 1
Heating Zone Valve 2
Solar Connections
Heating Return
Heat Pump return

Model
A
B
C
D
E
F
G
H
I
J
K

HUS210FTC4ST
1729
1370
1318
1516
1031
1174
892
757
366
416
492

HUS215FTC4ST
1729
1370
1318
1516
1043
1274
892
757
366
416
492

HUS300FTC4ST
2042
1680
1628
1516
1356
1274
892
757
366
416
492

The Domestic Heating Compliance Guide document L1A and L1B provides advice in
sizing both cylinder designated solar areas and heat exchangers to the surface area of the
solar collectors.

SEC RTN

E DC B A

H G F
K J I

2.21

1.121 Heating

Using this guide Mitsubishi Electric are able to offer the


following sizing advice for specification.

Model

DESIGNATED
SOLAR
VOLUME

HEAT PUMP
VOLUME

TOTAL
CAPACITY

HUS210FTC4ST

65

145

210

HUS215FTC4ST

90

160

250

HUS300FTC4ST

100

200

300

For further information please refer to the installation manual

HUS210-300FTC4ST
Pre-plumbed Solar Cylinder for Ecodan Monobloc Units

2.22

The packaged hydrobox offers a highly adaptable heating solution for retrofit or new build.

EHPX-VM2B

Packaged Hydrobox for


Ecodan Monobloc Units

Designed specifically by Mitsubishi Electric to integrate with the Ecodan monobloc air source heat pump range and a third party
cylinder, the hydrobox provides hydraulic components with an advanced simplified graphical user interface. Fast commissioning
via an SD card is also now available.

Key Features

FTC4 Controller

Simple graphical control


Capability to provide 2-zone energy efficient space heating control
Sleek modern design
Compatible with Mitsubishi Electric wireless room controllers
Pre-plumbed and wired for faster installation
Bivalent function, for use with conventional boilers
SD card commissioning

Mitsubishi Electrics fourth-generation


controller includes intelligent, room
temperature control as standard.
This together with advanced weather
compensation ensures the system
delivers efficient, comfortable heating
regardless of the season.

Cascade function for multiple unit control


Remote Wi-Fi control with MELCloud

MODEL

EHPX-VM2B

Operating Ambient Temperature (C DB)


Sound Pressure Level at 1m (dBA)
Water Data

Flow Rate (l/min) W50 - W85 - HW140


Pump
Connection Size (mm)
Primary Expansion Vessel (Litres)
Charge Pressure (MPa (Bar))
Control Thermistor (C)
Pressure Relief Valve (Mpa (Bar))
Flow Switch
Booster Heater Control Thermistor (C)
Booster Heater Manual Reset Thermostat (C)
Booster Heater Thermal Cut Off (C)
Width
Depth
Height

Water Safety Devices

Dimensions (mm)
Weight Empty / Full (kg)
Electrical Data

Control Board optionally powered


by outdoor unit
Booster Heater optionally powered
if required

Optional Simplified Wireless Room Thermostat and Wireless Receiver

*1 MCB Sizes BS EN60898-2 & BS EN60947-2

Electrical Supply
Phase
Fuse Rating - MCB Sizes (A)*1
Electrical Supply
Phase
Capacity (kW)
Max Running Current (A)
Fuse Rating - MCB Sizes (A)*1

0 ~ +35C (RH<80%)
28
14.3 - 25.8 - 40.1
Grundfos UPM2 25 70-180
28
10
0.1 (1)
1 - 80
0.3 (3)
Supplied
80
90
121
520
360
800
39 / 44
220-240v, 50Hz
Single
10
220-240v, 50Hz
Single
2
9
16

PAR-WT50-E Controller and PAR-WR51-E Receiver

Product Dimensions

EHPX-VM2B

Front View

Right View

Below View

Rear View

48
86
89
124
157
163
227

110.5

Letter
A

(233)

B
C
D
E
F

2.23

1.121 Heating

461

55.5

577

800
264.5

233

282
253
189
137
77
56

348
357

530

Pipe Description

Connection

Space heating/ Indirect DHW


tank (primary) return connection

28mm/Compression

Flow connection from heat pump


Return connection from heat pump
Space heating/ Indirect DHW
tank (primary) flow connection
Discharge pipe (by installer)
from pressure relief valve
Electrical cable inlets

28mm/Compression
28mm/Compression
28mm/Compression
G1/2 female (valve port
within hydrobox casing)
-

EHPX-VM2B Packaged Hydrobox


for Ecodan Monobloc Units

2.24

Our range of Ecodan split air source heat pumps includes 4, 7.5 and 12kW sizes.

PUHZ-SW

Ecodan Split Air Source


Heat Pumps

With the ability to cascade up to six units of the same output Ecodan split systems offer a capacity range from 4 to 72kW. Designed to
suit a wide number of applications, these models offer a viable solution for the varying requirements that domestic and small commercial
applications demand.

Key Features

Split unit allowing water connections to be made internally


No need for gas supply, flues or ventilation
Single phase power supply with a low starting current
Low maintenance and quiet to run
Operates with outside temperatures as low as -20C
Multiple unit connection
Bivalent function for use with conventional boilers
2-zone energy efficient space heating control
Remote Wi-Fi control with MELCloud

PUHZ-SW75VHA
PUHZ-SW120VHA

MODEL

Heating*1
(A-3/W35)
Heating*2
(A2/W35)
Heating*3
(A7/W35)
Operating Ambient Temperature (C DB)*7
Sound Pressure Level at 1m (dBA)*3*4
Low Noise Mode (dBA)*3
Water Data - Water connections made at indoor hydrobox
Dimensions (mm)
Weight (kg)
Refrigerant

Electrical Data

Certificate Number: MCS HP0002


Product Reference:
PUHZ-SW40VHA
PUHZ-SW75VHA
PUHZ-SW120VHA

Capacity (kW)
Power Input (kW)
COP
Capacity (kW)
Power Input (kW)
COP
Capacity (kW)
Power Input (kW)
COP

Flow Rate (l/min)


Width
Depth
Height
Type
Charge (kg) - 10m pipe length
Pipe Size - Gas/Liquid (mm (in))
Connection Type
Max Pipe Length (m)
Min Pipe Length (m)
Max Height Difference (m)
Electrical Supply
Phase
Nominal Running Current [MAX] (A)
Fuse Rating - MCB Sizes (A)*6

PUHZ-SW40VHA

3.8
1.27
2.99
4.0
1.24
3.24
4.1
0.85
4.80
-15 ~ +35C
45
42
11.8
800
300+23*5
600
42
R410A
2.1
12.7 (1/2") / 6.35 (1/4")
Flared
40
5
10
220-240v, 50Hz
Single
3.8 [13]
16

*1 Under normal heating conditions at outdoor temp: -3CDB / -4CWB, outlet water temp 35C, inlet water temp 30C
*2 Under normal heating conditions at outdoor temp: 2CDB / 1CWB, outlet water temp 35C, inlet water temp 30C as tested to BS EN14511
*3 Under normal heating conditions at outdoor temp: 7CDB / 6CWB, outlet water temp 35C, inlet water temp 30C as tested to BS EN14511
*4 Sound power level of the PUHZ-SW40VHA is 60.9dBA, PUHZ-SW75VHA2 is 65.6dBA, PUHZ-SW120VHA is 68.8dBA. as tested to BS EN12102
*5 Grille
*6 MCB Sizes BS EN60898-2 & BS EN60947-2
*7 Heating maximum ambient temperature ~21CDB, DHW Hot water maximum ambient temperature ~35CDB

PUHZ-SW75VHA

7.0
2.24
3.12
7.5
2.2
3.4
8.0
1.82
4.4
-20 ~ +35C
51
48
22.9
950
330+30*5
943
75
R410A
3.2
15.88 (5/8") / 9.52 (3/8")
Flared
40
5
10
220-240v, 50Hz
Single
8.1 [19]
25

PUHZ-SW120VHA

11.2
3.71
3.02
12.0
3.7
3.24
16.0
3.9
4.1
-20 ~ +35C
54
51
45.9
950
330+30*5
1350
118
R410A
4.6
15.88 (5/8") / 9.52 (3/8")
Flared
75
5
30
220-240v, 50Hz
Single
17.5 [29.5]
40

Product Dimensions

2.25

PUHZ-SW40VHA

Product Dimensions

PUHZ-SW75VHA

Product Dimensions

Upper View

Upper View

Upper View

Front View

Front View

Front View

1.121 Heating

PUHZ-SW120VHA

PUHZ-SW Ecodan Split Air Source Heat Pumps

2.26

The split hydrobox offers a highly adaptable heating solution for retrofit or new build.

EHSC-VM2B
Split Hydrobox

Designed specifically by Mitsubishi Electric to integrate with the Ecodan split air source heat pump range and a third party cylinder.
The split hydrobox provides hydraulic components with an advanced simplified graphical user interface. Fast commissioning via
an SD card is also now available.

Key Features

Simple graphical control


Capability to provide 2-zone energy efficient space heating control
Sleek modern design
Compatible with Mitsubishi Electric wireless room controllers
Pre-plumbed and wired for faster installation just requiring the
refrigerant connections to be made on site
Bivalent function, for use with conventional boilers
SD card commissioning
Cascade function for multiple unit control
Remote Wi-Fi control with MELCloud

FTC4 Controller
Mitsubishi Electrics fourth-generation
controller includes intelligent, room
temperature control as standard.
This together with advanced weather
compensation ensures the system
delivers efficient, comfortable heating
regardless of the season.

MODEL

EHSC-VM2B

Operating Ambient Temperature (C DB)


Sound Pressure Level at 1m (dBA)
Water Data

Flow Rate (l/min) SW40 - SW75 - SW120


Pump
Connection Size (mm)
Primary Expansion Vessel (Litres)
Charge Pressure (MPa (Bar))
Control Thermistor (C)
Pressure Relief Valve (MPa (Bar))
Flow Switch
Booster Heater Control Thermistor (C)
Booster Heater Manual Reset Thermostat (C)
Booster Heater Thermal Cut Off (C)
Width
Depth
Height

Water Safety Devices

Dimensions (mm)
Weight Empty / Full (kg)
Refrigerant
Electrical Data

Control Board optionally powered


by outdoor unit
Booster Heater optionally powered
if required

Optional Simplified Wireless Room Thermostat and Wireless Receiver

*1 MCB Sizes BS EN60898-2 & BS EN60947-

Type
Connection Size - Gas/Liquid (mm (in)
Connection Type
Electrical Supply
Phase
Fuse Rating - MCB Sizes (A)*1
Electrical Supply
Phase
Capacity (kW)
Max Running Current (A)
Fuse Rating - MCB Sizes (A)*1

0 ~ +35C (RH<80%)
28
11.8 - 22.9 - 45.9
Grundfos UPM2 25 70-180
28
10
0.1 (1)
1 - 80
0.3 (3)
Supplied
80
90
121
520
360
800
53 / 59
R410A
15.88 (5/8") / 9.52 (3/8")
Flared
220-240v, 50Hz
Single
10
220-240v, 50Hz
Single
2
9
16

PAR-WT50-E Controller and PAR-WR51-E Receiver

Product Dimensions

EHSC-VM2B

Front View

Right View

Below View

Rear View

348
48
86
124
163
227

326
381

461

55.5

264.5

590

800

357

233

189

137
96

253

282

530

110.5

Letter
A
B
C
D
E
F

2.27

1.121 Heating

Pipe Description

Connection

Space heating/ Indirect DHW


tank (primary) return connection
Space heating/ Indirect DHW
tank (primary) flow connection
Refrigerant (Liquid)
Refrigerant (Gas)
Discharge pipe (by installer)
from pressure relief valve

28mm/Compression

Electrical cable inlets

28mm/Compression
9.52mm/Flare
15.88mm/Flare
G1/2 female (valve port
within hydrobox casing)
-

EHSC-VM2B Split Hydrobox

2.28

MELCloud is a new Cloud based solution for controlling your Mitsubishi Electric Ecodan systems either
locally or remotely by PC, Mac, Tablet or Smartphone via the Internet.

Mobile Control
and Monitoring

Set up and remote operation of your Ecodan heating system via MELCloud is simple and straight forward. All you need is a wireless
connection in your home or building where the Ecodan is located and an Internet connection on your mobile or fixed device. To set up
the system, the router and the Ecodan Wi-Fi interface need pairing and this is done simply and quickly via the WPS button found on
all mainstream routers.

Key Features
View and control your heating and hot water from anywhere in the world
Holiday mode
Set up of 7 day weekly schedule
Temperature history reports
Operation mode reports
Live weather feed at location of Ecodan
Compatible with Apple, Android, Windows and Blackberry operating systems
Works on any PC / Mac / Tablet / Smartphone
Share / restrict access and control of the Ecodan system

Available for any FTC4 based system, new or retrofit using a PAC-WF010-E interface

Supported Ecodan Models


The following Mitsubishi Electric Ecodan units can be connected
to MELCloud via the Ecodan Wi-Fi Interface (PAC-WF010-E):

Description

Wi-Fi Interface

Cylinder Units

Connect to

Indoor Unit

Max Number of Units

EHPT20X-VM2HB

HU150/180/210/250/300FTC4ST
HUS210/250/300FTC4ST

See Table to the left

Power Supply

From Indoor Unit


88 x 18.5 x 49

On/Off

Hydrobox Units

Mode

EHSC-VM2B/6B

Heating Setpoint

EHPX-VM2B

Hot Water Boost

2-Zone Control

Holiday Mode

Timer

Frost Protection

On/Off

Mode

PAC-IF011/012/021/031/032/041B-E

Heating Setpoint

PAC-SIF051B-E

Tank Temperature

CAHV-P500YA-HPB

Outside Temperature

Fault Codes

Control

Flow Temperature Controller & Interface


PAC-IF052B-E

Models Not Supported


Monitor

EHPT20X-VM2HA
EHPX-VM2A

CRHV-P600YA-HPB

melcloud.com and click Login

Compatibility
Dimensions (WxDxH) mm

ECOSLIM-150L/180L-PP-MEUK

For a demonstration of
Mitsubishi Electrics
MELCloud visit website:

PAC-WF010-E

MODEL

Supported Hardware / Software


Supported Hardware / Software

Tablets (Apps or WebClient)

Smartphones (Apps or WebClient)

Operating Systems

Internet Browsers (WebClient only)

Apple iPad / iPad Mini

Apple iPhone

Android

Microsoft Internet Explorer

Samsung Galaxy Tab / Note

Samsung Galaxy S

Apple iOS / OS X

Google Chrome

Google Nexus

Google Nexus

Microsoft Windows 8

Apple Safari

Dell Latitude 10

Nokia Lumia

BlackBerry 10

Mozilla Firefox

Microsoft Surface

BlackBerry Z10

Opera

BlackBerry PlayBook

Please Note:

Available on PC, Mac, Tablet or Smartphone

2.29

1.121 Heating

This is not definitive list of all compatible devices, other similar devices which use supported Operating Systems or Internet Browsers should also work either via dedicated Apps or via
Web Browser / WebClient options. Please note that user experience may vary slightly depending on hardware and software combination.

MELCloud Mobile Control and Monitoring

2.30
Ecodan FTC4 Monobloc Standalone Systems
Ecodan PUHZ-W50VHA-BS & FTC4 Standalone System
Ecodan PUHZ-W85VHA2-BS & FTC4 Standalone System
Ecodan PUHZ-HW140VHA2-BS 1Ph & FTC4 Standalone System
Ecodan PUHZ-HW140YHA2-BS 3Ph & FTC4 Standalone System

Items included in the Ecodan FTC4 Monobloc Standalone Systems


Ecodan PUHZ-W50VHA-BS Monobloc Unit
Ecodan PUHZ-W85VHA2-BS Monobloc Unit
Ecodan PUHZ-HW140VHA2-BS Monobloc Unit
Ecodan PUHZ-HW140YHA2-BS Monobloc Unit
PAC-IF052B-E Flow Temperature Controller (FTC4) with main controller and TH1 Flow Sensor
TF1 - Magnetic Particle Filter - 22mm PUHZ-W50/W85VHA(2)
TF1 - Magnetic Particle Filter - 28mm PUHZ-HW140V/YHA2
Flexible Connection Pipes
Flow Meter
PAC-TH011TK-E - DHW Cylinder Sensor
Warranty Card
Ecodan Homeowner DVD
FTC4 Homeowner Quick Start Guide

Ecodan FTC4 Monobloc Packaged Cylinder Systems


Ecodan PUHZ-W50VHA-BS & 200 Packaged Cylinder System
Ecodan PUHZ-W85VHA2-BS & 200 Packaged Cylinder System
Ecodan PUHZ-HW140VHA2-BS 1Ph & 200 Packaged Cylinder System
Ecodan PUHZ-HW140YHA2-BS 3Ph & 200 Packaged Cylinder System

Items included in the Ecodan Monobloc Packaged Cylinder Systems


Ecodan PUHZ-W50VHA-BS Monobloc Unit
Ecodan PUHZ-W85VHA2-BS Monobloc Unit
Ecodan PUHZ-HW140VHA2-BS Monobloc Unit
Ecodan PUHZ-HW140YHA2-BS Monobloc Unit
EHPT20X-VM2HB FTC4 200 Packaged Cylinder
TF1 - Magnetic Particle Filter - 22mm PUHZ-W50/W85VHA(2)
TF1 - Magnetic Particle Filter - 28mm PUHZ-HW140V/YHA2
PAC-WK01UK-E - G3 Compliance Kit
Flexible Connection Pipes
Flow Meter
Warranty Card
Ecodan Homeowner DVD
FTC4 Homeowner Quick Start Guide

Ecodan FTC4 Monobloc Pre-Plumbed Slimline Cylinder Systems


Ecodan PUHZ-W50VHA-BS & 150 Pre-Plumbed Slimline Cylinder System
Ecodan PUHZ-W50VHA-BS & 180 Pre-Plumbed Slimline Cylinder System
Ecodan PUHZ-W85VHA2-BS & 150 Pre-Plumbed Slimline Cylinder System
Ecodan PUHZ-W85VHA2-BS & 180 Pre-Plumbed Slimline Cylinder System

Items included in the Ecodan Monobloc Pre-Plumbed Slimline Cylinder Systems


Ecodan PUHZ-W50VHA-BS Monobloc Unit
Ecodan PUHZ-W85VHA2-BS Monobloc Unit
ECOSLIM-150L-PP-MEUK Pre-Plumbed Slimline Cylinder
ECOSLIM-180L-PP-MEUK Pre-Plumbed Slimline Cylinder
Flexible Connection Pipes
Warranty Card
Ecodan Homeowner DVD
FTC4 Homeowner Quick Start Guide

Ecodan FTC4 Monobloc Pre-Plumbed Standard Cylinder Systems


Ecodan PUHZ-W50VHA-BS & 150 Pre-Plumbed Standard Cylinder System
Ecodan PUHZ-W50VHA-BS & 180 Pre-Plumbed Standard Cylinder System
Ecodan PUHZ-W85VHA2-BS & 150 Pre-Plumbed Standard Cylinder System
Ecodan PUHZ-W85VHA2-BS & 180 Pre-Plumbed Standard Cylinder System
Ecodan PUHZ-W85VHA2-BS & 210 Pre-Plumbed Standard Cylinder System
Ecodan PUHZ-HW140VHA2-BS 1Ph & 210 Pre-Plumbed Standard Cylinder System
Ecodan PUHZ-HW140VHA2-BS 1Ph & 250 Pre-Plumbed Standard Cylinder System
Ecodan PUHZ-HW140VHA2-BS 1Ph & 300 Pre-Plumbed Standard Cylinder System
Ecodan PUHZ-HW140YHA2-BS 3Ph & 210 Pre-Plumbed Standard Cylinder System
Ecodan PUHZ-HW140YHA2-BS 3Ph & 250 Pre-Plumbed Standard Cylinder System
Ecodan PUHZ-HW140YHA2-BS 3Ph & 300 Pre-Plumbed Standard Cylinder System

Items included in the Ecodan Monobloc Pre-Plumbed Standard Cylinder Systems


Ecodan PUHZ-W50VHA-BS Monobloc Unit
Ecodan PUHZ-W85VHA2-BS Monobloc Unit
Ecodan PUHZ-HW140VHA2-BS Monobloc Unit
Ecodan PUHZ-HW140YHA2-BS Monobloc Unit
HU150FTC4ST Pre-Plumbed Standard Cylinder
HU180FTC4ST Pre-Plumbed Standard Cylinder
HU210FTC4ST Pre-Plumbed Standard Cylinder
HU250FTC4ST Pre-Plumbed Standard Cylinder
HU300FTC4ST Pre-Plumbed Standard Cylinder
Flexible Connection Pipes
Warranty Card
Ecodan Homeowner DVD
FTC4 Homeowner Quick Start Guide

2.31

1.121 Heating

Prices

2.32
Ecodan FTC4 Monobloc Pre-Plumbed Solar Cylinder Systems
Ecodan PUHZ-W50VHA-BS & 210 Pre-Plumbed Solar Cylinder System
Ecodan PUHZ-W50VHA-BS & 250 Pre-Plumbed Solar Cylinder System
Ecodan PUHZ-W85VHA2-BS & 210 Pre-Plumbed Solar Cylinder System
Ecodan PUHZ-W85VHA2-BS & 250 Pre-Plumbed Solar Cylinder System
Ecodan PUHZ-W85VHA2-BS & 300 Pre-Plumbed Solar Cylinder System
Ecodan PUHZ-HW140VHA2-BS 1Ph & 210 Pre-Plumbed Solar Cylinder System
Ecodan PUHZ-HW140VHA2-BS 1Ph & 250 Pre-Plumbed Solar Cylinder System
Ecodan PUHZ-HW140VHA2-BS 1Ph & 300 Pre-Plumbed Solar Cylinder System
Ecodan PUHZ-HW140YHA2-BS 3Ph & 210 Pre-Plumbed Solar Cylinder System
Ecodan PUHZ-HW140YHA2-BS 3Ph & 250 Pre-Plumbed Solar Cylinder System
Ecodan PUHZ-HW140YHA2-BS 3Ph & 300 Pre-Plumbed Solar Cylinder System

Items included in the Ecodan Monobloc Pre-Plumbed Solar Cylinder Systems


Ecodan PUHZ-W50VHA-BS Monobloc Unit
Ecodan PUHZ-W85VHA2-BS Monobloc Unit
Ecodan PUHZ-HW140VHA2-BS Monobloc Unit
Ecodan PUHZ-HW140YHA2-BS Monobloc Unit
HUS210FTC4ST Pre-Plumbed Solar Cylinder
HUS250FTC4ST Pre-Plumbed Solar Cylinder
HUS300FTC4ST Pre-Plumbed Solar Cylinder
Flexible Connection Pipes
Warranty Card
Ecodan Homeowner DVD
FTC4 Homeowner Quick Start Guide

Ecodan FTC4 Monobloc Packaged Hydrobox Systems


Ecodan PUHZ-W50VHA-BS & Packaged Hydrobox System
Ecodan PUHZ-W85VHA2-BS & Packaged Hydrobox System
Ecodan PUHZ-HW140VHA2-BS 1Ph & Packaged Hydrobox System
Ecodan PUHZ-HW140YHA2-BS 3Ph & Packaged Hydrobox System

Items included in the Ecodan Monobloc Packaged Hydrobox Systems


Ecodan PUHZ-W50VHA-BS Monobloc Unit
Ecodan PUHZ-W85VHA2-BS Monobloc Unit
Ecodan PUHZ-HW140VHA2-BS Monobloc Unit
Ecodan PUHZ-HW140YHA2-BS Monobloc Unit
EHPX-VM2B Water Based Packaged Hydrobox
Flexible Connection Pipes
TF1 - Magnetic Particle Filter - 22mm PUHZ-W50/W85VHA(2)
TF1 - Magnetic Particle Filter - 28mm PUHZ-HW140V/YHA2
Flow Meter
PAC-TH011TK-E - DHW Cylinder Sensor
Warranty Card
Ecodan Homeowner DVD
FTC4 Homeowner Quick Start Guide

Ecodan FTC4 PUHZ Monobloc Cascade Systems


Ecodan 2 x PUHZ-W50VHA-BS Cascade Monobloc System
Ecodan 3 x PUHZ-W50VHA-BS Cascade Monobloc System
Ecodan 4 x PUHZ-W50VHA-BS Cascade Monobloc System
Ecodan 5 x PUHZ-W50VHA-BS Cascade Monobloc System
Ecodan 6 x PUHZ-W50VHA-BS Cascade Monobloc System
Ecodan 2 x PUHZ-W85VHA2-BS Cascade Monobloc System
Ecodan 3 x PUHZ-W85VHA2-BS Cascade Monobloc System
Ecodan 4 x PUHZ-W85VHA2-BS Cascade Monobloc System
Ecodan 5 x PUHZ-W85VHA2-BS Cascade Monobloc System
Ecodan 6 x PUHZ-W85VHA2-BS Cascade Monobloc System
Ecodan 2 x PUHZ-HW140VHA2-BS Cascade Monobloc System
Ecodan 3 x PUHZ-HW140VHA2-BS Cascade Monobloc System
Ecodan 4 x PUHZ-HW140VHA2-BS Cascade Monobloc System
Ecodan 5 x PUHZ-HW140VHA2-BS Cascade Monobloc System
Ecodan 6 x PUHZ-HW140VHA2-BS Cascade Monobloc System
Ecodan 2 x PUHZ-HW140YHA2-BS Cascade Monobloc System
Ecodan 3 x PUHZ-HW140YHA2-BS Cascade Monobloc System
Ecodan 4 x PUHZ-HW140YHA2-BS Cascade Monobloc System
Ecodan 5 x PUHZ-HW140YHA2-BS Cascade Monobloc System
Ecodan 6 x PUHZ-HW140YHA2-BS Cascade Monobloc System

Product
Please note: The items below are included with the kits, the prices below are individual item costs. For quantities included with the kit please contact your
Mitsubishi Electric representative.
Flexible Connection Pipes
PAC-IF052B-E FTC4 Master Controller
PAC-SIF051B-E FTC4 Slave Controller
Warranty Card
Ecodan Homeowner DVD
FTC4 Homeowner Quick Start Guide
Full Day Health Check/Commissioning

1 pair per outdoor


1 per cascade system
1 per outdoor unit
1 per cascade system
1 per cascade system
1 per cascade system
1 per cascade system

Multiple control of six 14kW


Ecodan PUHZ Units

2.33

1.121 Heating

Prices

2.34
Ecodan CAHV Monobloc Air Source Systems
Ecodan CAHV-P500YA-HPB Monobloc Air Source Unit, including commissioning

The Ecodan CAHV-P500YA-HPB model also has the cascade feature. This allows between 2 and 16 x CAHV-P500YA-HPB
units to be connected together, enabling system capacities up to 688kW.
Please note: Applications for cascade systems will be bespoke, and as a result the price will be on application.
Please contact your local Mitsubishi Electric representative, who will be pleased to give a price on this.

Ecodan CRHV Monobloc Ground / Water Source Systems


Ecodan CRHV-P600YA-HPB Monobloc Ground / Water Source Unit, including commissioning

The Ecodan CRHV-P600YA-HPB model also has the cascade feature. This allows between 2 and 16 x CRHV-P600YA-HPB
units to be connected together.
Please note: Applications for cascade systems will be bespoke, and as a result the price will be on application.
Please contact your local Mitsubishi Electric representative, who will be pleased to give a price on this.

Ecodan FTC4 Split Hydrobox Systems


Ecodan PUHZ-SW40VHA-BS & Split Hydrobox System
Ecodan PUHZ-SW75VHA-BS & Split Hydrobox System
Ecodan PUHZ-SW120VHA-BS & Split Hydrobox System

Items included in the Ecodan Split Hydrobox Systems


Ecodan PUHZ-SW40VHA-BS Split Unit
Ecodan PUHZ-SW75VHA-BS Split Unit
Ecodan PUHZ-SW120VHA-BS Split Unit
EHSC-VM2B Refrigerant Based Split Hydrobox
PAC-SH30RJ-E Joint Pipe (only included with PUHZ-SW40VHA-BS)
PAC-SH50RJ-E Joint Pipe (only included with PUHZ-SW40VHA-BS)
TF1 - Magnetic Particle Filter - 22mm PUHZ-SW40/SW75VHA
TF1 - Magnetic Particle Filter - 28mm PUHZ-HW140V/YHA2
Flow Meter
PAC-TH011TK-E - DHW Cylinder Sensor
Warranty Card
Ecodan Homeowner DVD
FTC4 Homeowner Quick Start Guide

DESCRIPTION

MODEL REF.

PUHZ Accessories

Accessories

Remote Sensor - A Wired Thermistor available for Room Temperature Monitoring


Drain Socket Set
Wireless Remote Controller Transmitter
Wireless Remote Controller Receiver

PAC-SE41TS-E
PAC-SH71DS-E
PAR-WT50R-E
PAR-WR51R-E

A wireless receiver should be purchased with a wireless transmitter. Up to 8 transmitters can be paired with 1 wireless receiver

PAC-RC01
PAC-TH011-E
PAC-TH011HT-E
PAC-TH011TK-E
ESPPMEUK2ZKIT
ESPPMEUKUPS2

Remote Controller Blanking Plate


Standard Sensor - for optional 2-Zone Control on Standalone Systems
High Temperature Sensor
DHW Cylinder Sensor
Slimline Cylinder 2 Zone Connection Kit
Slimline Cylinder Additional Pump
Fix-it foot 600 kit
Fernox HP-5C Antifreeze containing biocide 10ltr
Fernox HP-5C Antifreeze containing biocide 25ltr
3 wire adapter for low noise mode
Wi-Fi Interface

PAC-WF010-E

CAHV Accessories
CAHV-WH
CAHV-RS
CAHV-DP
TW-TH16
PAR-W21MAA-J
AG150A-J
PAC-SC51KUA
PAC-YG83UTB
PAC-YG81TB
PAC-YG85KTB
PAC-YG71CBL

Wind Hood (Four hoods supplied, two side and two rear)
Raised Stand
Drain Pan and Heater
Main Pipework Thermistor
Wired Remote Controller
Centralised Controller
Centralised Controller Power Pack
AG150 Back Box - for wall recessed mounting
AG150 Wall Mounted Box - for wall mounting
AG150 Panel - for wall mounting both AG150 and power pack
AG150 Black Cover

CRHV Accessories
TW-TH16
PAR-W21MAA-J
TMP-O

Main Pipework Thermistor


Wired Remote Controller
External Temperature Sensor

2.35

1.121 Heating

Accessories and Prices

Ventilation

Ventilation

Fresh Air

Ventilation
Range

Why Do We Need Fresh Air Ventilation?


Poor indoor air quality can be attributed to many problems inside a building. Excess
humidity causes dampness, rot and mould, whilst pollutants are known to be a major
cause of damaging health issues such as asthma and eczema. Stale air is also believed
to lead to a loss in productivity and low morale.
As the demand for improved energy efficiency results in increasingly airtight buildings, natural ventilation proves less effective
and drives the need for mechanical ventilation. With increasing legislation, the challenge for designers, installers and occupiers
of any building is to find ventilation thats both effective and energy efficient.
Mitsubishi Electric meets this need with a range of ventilation products covering mechanical ventilation with heat recovery units
(MVHR) and air handling units (AHUs). These systems have been designed to deliver a fresh air supply to a building whilst
simultaneously extracting stale air in the most energy efficient manner possible by utilising heat recovery technology.

Benefits include:
Clean, fresh air
Improved air quality and comfort
Increased climate control
Energy efficient heat recovery
Reduced energy bills

3.3

1.121 Ventilation

VENTILATION

Fresh Air Ventilation Range

3.4

Fresh Air

Ventilation
Range

The Unbeatable Lossnay


Excellent Air Quality and Heat Exchange Efficiency
Developed and refined over the past 35 years, the Lossnay system has perfected the recovery of energy that would have
otherwise been wasted. The units reduce overall energy costs by extracting stale air and then recovering the heating or
cooling energy to either warm or cool incoming fresh air.
By utilising this energy, the Lossnay system
can save up to 30% on initial capital costs
of heating and cooling plant by reducing
the load of the occupied space, resulting
in the need for a smaller heating and/or
cooling system.

Stale dirty
indoor air
(Exhaust Air)

Outdoors

Fresh air
into building
(Supply Air)

Indoors

Stale exhaust air


Fresh air from outside

Heat exchange unit


(Lossnay core)

As Lossnay extracts stale air from a building,


heat energy is recovered through the paper core
and is transfered into the fresh incoming air.
Stale room air extracted

How Lossnay Works

Fresh air supply to the room

The technology behind the energy efficiency of the Lossnay core lies in its construction which enables exchange of both
latent heat (humidity/moisture) and sensible heat (temperature) to maintain a comfortable internal environment for minimal
energy consumption.

Fresh air
introduction
(Outdoor Air)

Stale air
removed from
building
(Return Air)

The core is made from ultra-thin paper and sits at the heart of the system. Constructed in a corrugated form and layered in alternate
directions, the core allows a cross airflow to maximise heat recovery without the supply and exhaust air mixing, ensuring only fresh air
is introduced into a building.
The use of ultra-thin paper enables the unit to achieve high enthalpy exchange efficiency and dramatically increases moisture permeability
whilst acting as a barrier against air leakage.

Fresh Air

Ventilation
Range

Lossnay
The 3 ranges of Lossnay units have been developed to suit both commercial and domestic
applications and have Lossnay total heat exchanger cores within them ensuring effective
fresh air ventilation whatever the building type.
VL-100(E)U5-E
The wall mounted VL-100(E)U5-E single room total heat exchangers are suitable for applications such as small offices and homes.
These compact and easy-to-install units offer a supply of fresh clean air, whilst removal of stale air with efficient recovery of heating /
cooling energy. This enables a fresh, clean and healthy internal environment to be maintained whilst reducing heating/ cooling costs.

DC Lossnay
The DC Lossnay unit benefits from DC fan motors which consume minimal energy, allowing for highly efficient, effective fresh air
ventilation. The fan motors have also been designed to control with quiet operation making them suitable for schools, offices and
homes. With 5 different fan speeds, a free cooling function and the option of integrating with a CO2 sensor, the DC Lossnay units
operate to maximise air quality and occupant comfort in an energy efficient manner.

RX5
With 9 units available, the Lossnay RX5 range of MVHR units cover a wide range of air volumes making them suitable for most
commercial applications. These highly efficient total heat exchangers utilise the Lossnay heat recovery core to provide fresh air to a
building whilst removing stale air and pollutants with minimal heat loss. Efficiency is further enhanced with a free cooling function that
lowers the cooling demand of a building and therefore saves on running costs.

Simple technology at its best


Many of our Lossnay cores are registered on the Energy Technology List
and hence qualify for enhanced capital allowances.

For further information please go to etl.decc.gov.uk/etl

3.5

1.121 Ventilation

Fresh Air Ventilation Range

3.6

Fresh Air

Ventilation
Range

Lossnay Kanzen
The Lossnay Kanzen range of units are highly efficient packaged Air Handling Units
(AHUs) that provide a tempered fresh air supply to commercial buildings alongside
an air conditioning system.
The AHUs are connected to Mr Slim Power Inverter heat pump units allowing fresh air to be
heated or cooled via a DX coil before being supplied to the internal environment as required,
with the added benefit of total heat recovery using Lossnay cores.
Efficiency is further enhanced as the Lossnay Kanzen units offer a free cooling function whereby in cooling mode, at a certain preset
temperature, the AHU will stop the operation of the outdoor units and open the bypass damper to allow cooler ambient air to bypass
the Lossnay cores and lower the internal temperature of the building, therefore reducing the load on the air conditioning system.
With an integrated controls system that includes an interface that uses M2M technology, the Lossnay Kanzen units offer a high level of
in-built control to ensure that the demand for a comfortable supply of fresh air within a building is met, whilst making sure that the units
are working in the most energy efficient manner possible. BEMS (Building Energy Management System) control of the Lossnay Kanzen
units and up to 49 City Multi indoor units (On/Off, Mode, Setpoint, Fault and Return Air) via the AG-150 centralised controller is possible.

Available in 5 different sizes and with a large range of optional extras available, the Lossnay Kanzen units are
customisable and therefore suitable for most commercial applications.

Standard Lossnay Kanzen Package


Pre-heater

Bypass Damper

Integrated Controls System

Free cooling & night purge bypass shutter


Energy saving feature that uses
cool outdoor air to lower the
internal temperature

Activated at external
temperatures from
0C to -5C
Modulated control

Electronic panel with integrated


regulation systems
Blue light backlit display
Operating parameters display
Error display
Optional ON/OFF and time-clock schedule using AG-150 and PAC-YG66DCA
Control interface that uses M2M technology
BEMS control available

Outside Air
Return Air

Supply Air
Exhaust Air

Electric Motor
High efficiency adjustable electric motor
Low noise electronic switching technology
Motor mated directly to external fan rotor

Lossnay Core
High efficiency Lossnay Core
Total heat recovery (sensible & latent)
Cross-flow plate fin structure
Paper core

3.7

1.121 Ventilation

High Efficiency Active


Carbon Filter Section
F7 active carbon bag filter
upstream of the DX coil
G4 filters (outdoor air & return air)
protect the Lossnay cores

Direct Expansion Coil


R410A refrigerant direct expansion coil
Copper tubing with Blu-Fin V Waffle louver
fins in corrosion resistant aluminium
46 bar rated pressure

Fresh Air Ventilation Range

3.8

Fresh Air

Ventilation
Range

Lossnay Kanzen Controls


The M2M technology allows the Lossnay Kanzen to be monitored and controlled
from a BEMS using the well-established Modbus protocol. It also allows monitoring
and control of up to 49 indoor units when the M2M interface is connected to the
centralised controller using an Ethernet cable.

Lossnay Kanzen AHU

Modbus RTU
RS485 or TCP/IP
Indoor Unit Registers Available:
On/Off
Mode
Setpoint
Return Air Temperature
Fault

ETHERNET

AG150
M-NET

Fresh Air

Ventilation
Range

Contents
Features Key

Lossnay VL-100(E)U5-E Wall Mount

3.10

Lossnay LGH-RSDC-E1 DC Model

3.12

Lossnay LGH-RX5-E Commercial Series

3.14

Lossnay Kanzen LK Air Handling Units

3.16

Lossnay Kanzen LK Accessories

3.18

Optimised Rotary or Sroll Compressor


Inverter Control - adjusts performance to economically
match the demand for heating or cooling
Auto-Restart

Quiet Operation
Hot Start - draught prevention
Standard Filter
Optional High Efficency Filter
High External Static Pressure
Optional High Static Fan Motor
Demand Control

3.9

1.121 Ventilation

VENTILATION

Fresh Air Ventilation Range

3.10

VL-100(E)U5-E

The VL-100(E)U5-E units supply fresh air inside a room using simultaneous supply and extract operation
in an energy efficient manner.

Wall Mount

The recovery of both latent heat and sensible heat ensures a comfortable internal environment as well as reducing heat losses hence
saving both energy and costs.

Key Features

Effective fresh air ventilation


Improved air quality and comfort
Efficient heat recovery
Good sound attenuation
Reduces heating / cooling costs
Simple installation
Low power consumption
Low maintenance
Available as pull cord or external switch type
Total heat exchange (sensible and latent)

VL-100(E)U5-E

WALL- MOUNTED
ELECTRICAL POWER SUPPLY
PHASE

POWER CONSUMPTION (W)


AIRFLOW (m3/h)
SOUND PRESSURE LEVEL (dBA)
TEMPERATURE EXCHANGE EFFICIENCY (%)
WEIGHT (kg)

DIMENSIONS (mm)

220-240V, 50Hz
Low
High
Low
High
Low
High
Low
High
Width
Depth
Height

DUCT SIZE (mm)

FUSE RATING (BS88) - HRC (A)


MAINS CABLE No. Cores

Single
17
34
61

106
27
38
79
72

7.5

620
200
265

2 x 75
6
3

Notes: The VL-100U5-E includes a pull cord switch to control the unit. Also available as VL-100EU5-E which includes the option to fit a field supplied external wall switch

VL-100(E)U5-E

Upper View

POWER CORD HOLE

620
SHUTTER KNOB
(CLOSED POSITION)

75

(ADJUST
ABLE)
267.5

AIR EXHAUST HOLE


85 to 90 WALL HOLE

SHUTTER KNOB
(OPEN POSITION)

200(MIN)
350(MAX)

75

360min

150

OUTER DIA
792

OU TER D
IA
752

12
FRONT PANEL LOUVER
(HORIZONTAL POSITION)
17

22
54
226

200

WALL THICKNESS
50 to 550

106

Unit: mm

Notes: The VL-100U5-E includes a pull cord switch to control the unit. Also available as VL-100EU5-E which includes the option to fit a field supplied external wall switch

3.11

1.121 Ventilation

VL-100(E)U5-E Wall Mount

233min

183min
from nearest
obstruction

13.5

AIR INTAKE HOLE


85 to 90 WALL HOLE

FRONT PANEL
(OPEN POSITION)

FRONT PANEL LOUVER


(VERTICAL POSITION)

238.5

292

Side View

FRONT PANEL
(CLOSED POSITION)

265

(ADJUST
ABLE)

530
554
620
360min from nearest obstruction

PITCH 20X10=200

97
87

15

95.5
140

90

FRESH AIR SUPPLY

25

MOUNTING HOLES
366

119

420

EDGE OF MAIN UNIT

95

REQUIRE TO BE SECURED

40

INDOOR AIR EXHAUST

REQUIRE TO BE SECURED

108

MOUNTING PLATE

(ADJUSTABLE)

Front View

25

Product Dimensions

3.12

LGH-RSDC-E1

Particularly suitable for modern homes with high insulation afforded by double glazing and
cavity insulation, which require ventilation to remove stale air without major heat loss.

DC Lossnay Model

This model is also suitable for a number of non-residential applications such as schools.

Key Features
Effective fresh air ventilation
Efficient recovery of heating/cooling energy
Good sound attenuation
Reduces heating costs
Low power consumption with 5 variable fan speeds
Hyper Eco Core facilitating improved humidity penetration
By-pass mode for free cooling. Including new power mode to supply
a greater volume of fresh, cool air - for instance during summer nights
SAP Appendix Q eligible
Optimise the fan speed based on CO2 level using the Lossnay-5-FSC interface
Total heat exchange (sensible and latent)

LGH-50RSDC-E1

DC LOSSNAY

220-240V, 50Hz

ELECTRICAL POWER SUPPLY


STARTING CURRENT (A)
FAN SPEED

INPUT POWER (W)


AIRFLOW (m3/h)

AIRFLOW (l/s)

EXTERNAL STATIC PRESSURE (Pa)


SOUND PRESSURE LEVEL (dBA)

TEMPERATURE EXCHANGE EFFICIENCY (%)


ENTHALPY EXCHANGE EFFICIENCY (%)
WEIGHT (kg)

DIMENSIONS (mm)

Heating
Cooling
Width
Depth
Height

DUCT SIZE (mm)

FUSE RATING (BS88) - HRC (A)


MAINS CABLE No. Cores

2.5

LOSSNAY

VENTILATION MODE

1
165
395
110
100
31
77.5
71
68

2
90
305
85
60
26.5
81.5
75
72.5

3
41
215
60
30
21
85.5
79
77

4
22
144
40
15
18
88
82
80.5

5
14
90
25
7
18
90
84
83

POWER
265
468
130
135
35
48

1099 + 73
898
302
200
6
3

BYPASS

1
164
395
110
100
31
-

2
90
305
85
60
26.5
-

3
40
215
60
30
21
-

4
21
144
40
15
18
-

5
14
90
25
7
18
-

Accessories

Product Dimensions

LGH-50RSDC-E1

Controllers
Lossnay-5-FSC
Lossnay Fan Speed Controller

Upper View

Front View

DC-5

Right Side View

Lossnay Fan Speed Controller

Left Side View

Rear View

3.13

1.121 Ventilation

LGH-50RSDC-E1 DC Lossnay Model

3.14

LGH-RX5-E
Commercial Series

This commercially orientated system can be utilised virtually anywhere.

Key Features

Effective fresh air ventilation


High heat recovery
Free cooling function
Good sound attenuation
Total heat exchange (sensible and latent)
Hyper Eco Core. At only 25m the Lossnay core uses one of the thinnest papers in the world to achieve high enthalpy exchange efficiency
The Lossnay-5-FSC Interface can also be used with LGH-RX5-E units. However, automatic fan speed control is with 3 speeds
Use in conjunction with Mr Slim and City Multi for highly efficient and effective operation

COMMERCIAL MODELS
ELECTRICAL POWER SUPPLY
STARTING CURRENT (A)
RUNNING CURRENT (A) Extra Low
Low
High
Extra High
INPUT POWER (W)
Extra Low
Low
High
Extra High
3
*2
AIRFLOW (m /h)
Extra Low
Low
High / Extra High
*2
AIRFLOW (l/s)
Extra Low
Low
High / Extra High
EXTERNAL STATIC
Extra Low
PRESSURE (Pa)
Low
High
Extra High
SOUND
Lossnay Extra Low
PRESSURE
Low
LEVEL
High
(dBA)
Extra High
Bypass Extra Low
Low
High
Extra High
TEMPERATURE
Extra Low
EXCHANGE
Low
EFFICIENCY (%) High
Extra High
ENTHALPY
Heating Extra Low
EXCHANGE
Low
EFFICIENCY (%)
High / Extra High
Cooling Extra Low
Low
High / Extra High
WEIGHT (kg)
DIMENSIONS (mm)
Width
Depth
Height
DUCT SIZE (mm)
*1
STANDARD FILTER
FUSE RATING (BS88) HRC (A)
MAINS CABLE NO. CORES

LGH15RX5-E

LGH25RX5-E

LGH35RX5-E

LGH50RX5-E

LGH65RX5-E

LGH80RX5-E

LGH100RX5-E LGH150RX5-E LGH200RX5-E

220-240V, 50Hz
0.8
0.15
0.25
0.38
0.46
35
59
90
110
70
110
150
19
31
42
14
40
70
105
18
23.5
27
28
19
24
28
29
85.5
84
82
82
81
77.5
75
81
76.5
73
20
735
780
273
100
EU-G3
6
3

220-240V, 50Hz
0.9
0.18
0.27
0.48
0.55
42
62
114
129
105
155
250
29
43
69
9
25
60
85
19
21.5
26
27
19
22
26.5
27.5
83.5
81.5
79
79
77.5
74
69.5
76
72.5
68
20
735
780
273
150
EU-G3
6
3

220-240V, 50Hz
2.4
0.30
0.51
0.74
0.92
69
116
169
212
115
210
350
32
58
97
9
30
80
160
18
23
29.5
32
18
24
30.5
32.5
88
85
80
80
81.5
76.5
71.5
81
75.5
71
29
874
888
315
150
EU-G3
6
3

220-240V, 50Hz
3.0
0.40
0.85
1.00
1.25
95
190
228
286
180
390
500
50
108
139
10
60
90
155
19
28
32
34
19
29
32.5
35
86
81
78
78
78
71
69
77
68
66.5
32
1016
888
315
200
EU-G3
6
3

220-240V, 50Hz
4.4
0.60
1.20
1.50
1.80
140
265
322
380
265
520
650
74
144
181
8
50
80
120
22
31.5
33
34.5
22.5
30.5
33.5
35
86
80
77
77
78
70.5
68.5
77
68.5
66
40
954
908
386
200
EU-G3
6
3

220-240V, 50Hz
3.8
0.65
1.45
1.60
1.75
145
340
370
415
355
700
800
99
194
222
20
95
120
150
22
31
33
34.5
22
32
34
35.5
87.5
80.5
79
79
79.5
72.5
71
79.5
71.5
70
53
1004
1144
399
250
EU-G3
6
3

220-240V, 50Hz 220-240V, 50Hz 220-240V, 50Hz


4.6
7.3
11.9
0.90
1.70
2.90
3.40
2.10
3.20
4.20
2.40
3.50
4.80
200
380
680
785
475
740
980
535
830
1100
415
755
1300
1580
1000
1500
2000
115
210
361
439
278
417
556
18
60
100
65
110
135
105
170
175
165
22
32.5
35
34
35
37.5
38
37
39
40
22
33
37
35
36
39
39
38
40.5
41
87
83
81
83
80
80
80
80
80
80
80
74
72.5
73.5
72.5
72
72.5
79
73
71.5
72
71
70.5
71
59
105
118
1231
1004
1231
1144
1144
1144
399
798
798
250
(SA,RA)250 (OA,EA) 270x700 (SA,RA)250 (OA,EA) 270x700
EU-G3
EU-G3
EU-G3
6
10
16
3
3
3

Notes: Running Current, Input Power and Recovery Efficiency are based on the above airflow rate, power supply 240v, 50Hz. Extra High and High mode available via dip switch setting.
Extra Low mode not available on sizes 150 and 200. Sound Pressure Level measured at 1.5m under the centre of panel. *1: EU-F7 filter available as optional parts. *2: Airflow tested to Japan industrial standard JIS B 8628.

Accessories
Remote Controllers
PZ-60DR-E

Product Dimensions

LGH-15/25/35/50/65/80/100RX5-E

Side View

Top View

Front View

Position where duct direction change is possible


By-pass damper plate

Lossnay Remote Controller for LGH RX5-E

Ceiling suspension fixture

Lossnay-5-FSC

High efficiency filter

Lossnay Fan Speed Controller

Air exhaust fan

(4-13x20 oval)

(sold separately)
attachment position
A

Lossnay Fan Speed Controller

RA
(return air)

EA
(exhaust air outlet)
E

DC-5

High Efficiency Filters


PZ-25RFM
High efficiency filter for LGH-15RX5-E / LGH-25RX5-E

duct direction
change is possible

Air supply fan


Inspection
opening

Maintenance cover

High efficiency filter for LGH-50RX5-E

Side View

Top View
(sold separately)

44

1144

79

(4-15x30 oval)

EA
(exhaust air outlet)

RA
(return air)

700

High efficiency filter for LGH-100RX5-E /


LGH-200RX5-E (2 sets)

SA
(supply air)

270

Efficiency filter, fan,


Maintenance space

150~250

Core, air filter, High-

More than 600

27

258

242

OA
(outside air intake)
Air filters(EU-G3)

Ceiling suspension fixture

PZ-100RFM

1010

Air exhaust fan

attachment position

LOSSNAY core

Front View

By-pass damper plate

High efficiency filter

High efficiency filter for LGH-80RX5-E /


LGH-150RX5-E (2 sets)

LGH-150/200RX5-E

270

PZ-80RFM

Product Dimensions

258

High efficiency filter for LGH-65RX5-E

242

PZ-65RFM

Control box

110

PZ-50RFM

Core, air filter, HighEfficiency filter, fan,


Maintenance space

Position where

LOSSNAY core

150 ~250

High efficiency filter for LGH-35RX5-E

Power supply
cable opening

Air filters (EU-G3)


More than 600

PZ-35RFM

SA
(supply air)

OA
(outside air intake)

Inspection
opening

399
798

Air supply fan


Control box

Power supply
cable opening

Maintenance cover

Notes: Please use the Lossnay Technical Databook for specific, individual model schematics.

Model Reference

3.15

1.121 Ventilation

Ceiling Suspension
Fixture Pitch

Dimensions

Nominal
Diameter

LGH-15RX5-E

780

735

273

768

782

100

LGH-25RX5-E

780

735

273

768

782

150

LGH-35RX5-E

888

874

315

875

921

150

LGH-50RX5-E

888

1016

315

875

1063

200

LGH-65RX5-E

908

954

386

895

1001

200

LGH-80RX5-E

1144

1004

399

1010

1036

250

LGH-100RX5-E

1144

1231

399

1010

1263

250

Model Reference

LGH-150RX5-E

1004

690

1045

LGH-200RX5-E

1231

917

1272

LGH-RX5-E Commercial Series

3.16

Lossnay Kanzen
Air Handling Units

The new Lossnay Kanzen Air Handling Units (AHUs) utilise Mr Slim Power Inverter heat pump technology,
Lossnay heat recovery technology and an integrated controls system making them highly advanced and efficient.

Key Features

Mr Slim Power Inverter heat pump technology


Total heat recovery with Lossnay cores
Integrated controls
High efficiency system
Flexible installation / configuration
Compatible with Modbus (RS485)
Customisable units with extensive optional extras available

LK-500

LK-750

LK-1000

LK-1250

5,000

7,500

10,000

12,500

15,000

3,500 - 5,000

5,500 - 7,500

8,000 - 10,000

10,500 - 12,500

13,000 - 15,000

250

250

250

250

250

51.5

MODEL
Rated Airflow

Cooling / Heating

m3/h
m3/s
m3/h
m3/s
Pa
Pa
kW
kW
kW
kW
kW
kW
%
%

Supply Fan(s) (250Pa)


Return Fan(s) (250Pa)
Auxillary Transformer
Total for Lossnay Kanzen

kW
kW
kW
kW

Airflow Range
Max. Static Pressure (factory settings)
Max. Static Pressure (configuration option)
Cooling (Rated)

Heating (Rated)

Sensible Heat Recovery Efficiency


Total Heat Recovery Efficiency
Number of Lossnay Heat Recovery Modules
Power Input (Rated/Max)

COP / EER (Rated)


Filter Section
Outdoor Unit
Unit Dimensions
Unit Weight
Outdoor Unit Dimensions
Outdoor Unit Weight
Electric Pre-heating Coil

Coil Capacity
Recovery Module Capacity
Total Capacity
Coil Capacity
Recovery Module Capacity
Total Capacity

Mr Slim Heat Pump

0.97 - 1.39

(WxDxH)
(WxDxH)

Power Input

Rated/Max

kW

(WxDxH)

2.08

2.78

1.53 - 2.08

400

2.22 - 2.78

400

400

3.47

2.92 - 3.47

4.17

3.61 - 4.17
400

400

21.3

26.6

42.3

46.0

36.6

49.5

72.9

84.2

97.4

90.7

108.9

15.3

22.9

25.0
61.3

72.6

85.9

72

120.1

72

57.0

50.7

47.5

54.4

45.9

38.2

30.6

31.5

36.3

72

141.4

165.9

72

72

62 / 67

62 / 67

62 / 67

62 / 67

62 / 67

2.1 / 2.7

2.9 / 3.1

3.7 / 4.7

4.5 / 4.7

5.8 / 6.2

4.6 / 5.4
10.4 / 11.9

Rigid pocket, Class F7 (EU7)

Rigid pocket, Class F7 (EU7)

Rigid pocket, Class F7 (EU7)

PUHZ-RP200YKA +

2 x PUHZ-RP250YKA

4450 x 1870 x 2300

4550 x 1870 x 2300

5150 x 2000 x 2300

5090 x 2780 x 2300

2380

2540

2760

3190

2960

3210
2 x (1050 x 330 + 30 x 1338)

2.9 / 3.1

0.15

0.2

4.65 / 5.95

Rigid pocket, Class F7 (EU7)

Rigid pocket, Class F7 (EU7)

4450 x 1200 x 2300


1950

4870 x 1200 x 2430

12

8.3 / 9.6

1.6 / 2.7

0.15

7.01 / 4.23

10

3.6 / 4.7

1.6 / 2.7
3.85 / 5.55

PUHZ-RP200YKA

mm
mm
kg
kg
mm
kg
kW

Monobloc*1
6 Sections
Monobloc*1
6 Sections

1.39

LK-1500

7.88 / 4.63

PUHZ-RP250YKA

6.8 / 8.0

7.23 / 4.44

2 x PUHZ-RP200YKA

4450 x 1870 x 2430

2150

4950 x 1870 x 2430

2650

2800

0.2

7.27 / 4.40

PUHZ-RP250YKA

5500 x 2000 x 2430

0.3

6.86 / 4.10

5090 x 2780 x 2430

1050 x 330 + 30 x 1338

1050 x 330 + 30 x 1338

2 x (1050 x 330 + 30 x 1338)

2 x (1050 x 330 + 30 x 1338)

135

141

135 + 135

141 + 135

141 + 141

20

24

LK-500

LK-750

LK-1000

LK-1250

LK-1500

2.9 / 5.5

3.7 / 5.5

5.7 / 11.0

6.4 / 11.0

7.3 / 11.0

1.9 / 2.7

2.9 / 3.0

3.5 / 4.7

4.4 / 4.7

0.15

0.15

0.20

0.20

4.95/8.35

6.75/8.65

9.30/15.90

11.00/15.90

13.4/17.30

LK-1250

LK-1500

12

16

Extensive optional extras are also available

CONFIGURATION OpTIONS
Supply Fan (400Pa) Power Input
Return Fan (400Pa) Power Input
Auxillary Transformer

Total for Lossnay Kanzen

Rated/Max
Rated/Max

kW

kW

kW

ACCESSORIES
Vapour Humidification Section
Electric Post-heating Coil

LK-500
Power Input

Power Input

kg/h
kW

kW

Rated airflow is at effective static pressure of 250Pa

LK-1000

0.30

45

15

18

25

35

11.2

13.5

18.7

26.2

12

16

20

RATED CONDITIONS
*1 The LK-1500 unit is not available as a Monobloc version and comes in 3 sections as standard.

LK-750

5.8 / 6.0

33.7
24

Winter

Summer
Indoor

21C DB

50% RH

Indoor

21C DB

50% RH

Outdoor

27C DB

50% RH

Outdoor

2.5C DB

50% RH

Product Dimensions
Front View

Product Dimensions

LK-500

Side View

Top View

Electric Pre Heater


Battery

Side View

E.P.

Return
Air

Outside
Air.

Exhaust
Air

Section A-A

E.P.

Return
Air

Outside
Air

E.P.
B

Bypass Shutter

Return
Air

Outside
Air

Top View

Electric Pre Heater


Battery

Bypass Shutter

Section A-A

Front View

LK-750

Core
Removal

Front View

Core
Removal

Exhaust
Air

Supply
Air

Product Dimensions

Product Dimensions

LK-1000

Side View

Top View

Front View

3+3
Cores

Side View

Top View

Bypass Shutter

Section A-A
E.P.

Section A-A
A

Return
Air

Outside
Air.

Outside
Air

Return
Air

Front View

Supply
Air

Exhaust
Air

E.P.

5+5
Cores

Supply
Air

LK-1500

Side View

Top View

Electric Pre Heater


Battery

Bypass Shutter
Return
Air

E.P.

Section A-A
Return
Air

Outside
Air.

Outside
Air

Core
Removal
Exhaust
Air

4+4+4
Cores
Supply
Air

E.P.

1.121 Ventilation

Return
Air

Outside
Air.

Core
Removal

Core
Removal

Bypass Shutter

E.P.

Return
Air

Product Dimensions

E.P.

LK-1250

Outside
Air

Exhaust
Air

Supply
Air

Electric Pre Heater


Battery

Electric Pre Heater


Battery
A

3.17

Return
Air

Outside
Air.

Lossnay Kanzen Air Handling Unit

E.P.

3.18

Fresh Air

DESCRIPTION

Ventilation
Range

Lossnay Kanzen
Accessories

MODEL REF.

Vapour Humidifcation Section


Vapour Humidifcation Section for LK-500

pT-5000SUV-3

Vapour Humidifcation Section for LK-750

pT-7500SUV-3

Vapour Humidifcation Section for LK-1000

pT-10000SUV-3

Vapour Humidifcation Section for LK-1250

pT-12500SUV-3

Vapour Humidifcation Section for LK-1500

pT-15000SUV-3

Vapour Humidifcation Section for LK-500 in 6 Sections

pT-5000SUV-6S

Vapour Humidifcation Section for LK-750 in 6 Sections

pT-7500SUV-6S

Vapour Humidifcation Section for LK-1000 in 6 Sections

pT-10000SUV-6S

Vapour Humidifcation Section for LK-1250 in 6 Sections

pT-12500SUV-6S

Vapour Humidifcation Section for LK-1500 in 6 Sections

pT-15000SUV-6S

External Anti-freeze Bypass


External Anti-freeze Bypass for LK-500

pT-5000BpAE

External Anti-freeze Bypass for LK-750

pT-7500BpAE

External Anti-freeze Bypass for LK-1000

pT-10000BpAE

External Anti-freeze Bypass for LK-1250

pT-12500BpAE

External Anti-freeze Bypass for LK-1500

pT-15000BpAE

post-heating System
Post-heating System for LK-500

pT-5000BpM-3

Post-heating System for LK-750

pT-7500BpM-3

Post-heating System for LK-1000

pT-10000BpM-3

Post-heating System for LK-1250

pT-12500BpM-3

Post-heating System for LK-1500

pT-15000BpM-3

Two Speed pCB


Two Speed PCB for Lossnay Kanzen Units

pT-SDV-3

Fresh Air

DESCRIPTION

Ventilation
Range

Lossnay Kanzen
Accessories

MODEL REF.

High Static pressure Fans


400Pa High Static Pressure Fans for LK-500

pT-5000Ap-3

400Pa High Static Pressure Fans for LK-750

pT-7500Ap-3

400Pa High Static Pressure Fans for LK-1000

pT-10000Ap-3

400Pa High Static Pressure Fans for LK-1250

pT-12500Ap-3

400Pa High Static Pressure Fans for LK-1500

pT-15000Ap-3

High Efficiency Filter


High Efficiency F9 Filter for LK-500

pT-5000FTF9-3

High Efficiency F9 Filter for LK-750

pT-7500FTF9-3

High Efficiency F9 Filter for LK-1000

pT-10000FTF9-3

High Efficiency F9 Filter for LK-1250

pT-12500FTF9-3

High Efficiency F9 Filter for LK-1500

pT-15000FTF9-3

Left-hand Connection
Left-handed Connections for Lossnay Kanzen units

pT-51015LASX

6 Sections

3.19

1.121 Ventilation

Subdivision into 6 Sections for LK-500

pT-5000-6SEZ

Subdivision into 6 Sections for LK-750

pT-7500-6SEZ

Subdivision into 6 Sections for LK-1000

pT-10000-6SEZ

Subdivision into 6 Sections for LK-1250

pT-12500-6SEZ

Subdivision into 6 Sections for LK-1500

pT-15000-6SEZ

Lossnay Kanzen Accessories

Controls

Controls

The Importance of

Controls

The need for control is paramount in order to optimise the performance


of any air conditioning, heating or ventilation system and minimise its
running costs and the emissions generated. Mitsubishi Electric offer a
wide range of control options designed to do just this.
Operating an air conditioning, heating or ventilation system without the right control can prove
costly. Its therefore important to ensure that every system is correctly specified and integrated
within the building to the degree of control it requires. Mitsubishi Electric have a wide range of
controls available off-the-shelf and where needed, individual control systems can be specifically
designed to suit.

Good controls will benefit any application, large or small. Our range of products need to react to a variety of factors:
different room sizes, usage and customer levels, changes in the climate, electronic equipment and lighting etc.
The ability to monitor the energy consumption and operation of systems is also vital. It is often said that you cannot
manage what you are not measuring. Our control systems will enable simple measuring and monitoring of energy
consumption and running costs to ensure operation is maintained.
So whatever the application, optimum control of our systems is essential and will result in a constant,
comfortable environment, which in turn is both energy and cost efficient.

A Degree of Difference
When an air conditioning, heating or ventilation system is not properly controlled, it will not run as efficiently as it should.
For every degree that the system deviates from the required temperature, energy costs can rise by up to 5%. Specify one
of the many control options from Mitsubishi Electric to ensure our products work as intended, whilst giving the optimum
amount of control.

4.3

1.121 Controls

The Importance of Controls

4.4

The Importance of

Controls

The Internet of Things (or IoT) describes the revolution already


under way that is seeing a growing number of Internet-enabled
devices that can network and communicate with each other
and with other web-enabled gadgets.
Mitsubishi Electric is at the forefront of this revolution and all our products
are now connectable to the Internet using the following solutions*1.
MELCloud
MELCloud is a new Cloud based solution for controlling your Mitsubishi Electric Air Conditioning*2 and Heating*3 systems either
locally or remotely by PC, Mac, Tablet or Smartphone via the Internet. The Wi-Fi interface connects directly to your system and
provides a wireless connection to your wireless router, enabling monitoring and control of your system from anywhere in the world.
For a demonstration of
Mitsubishi Electrics MELCloud
visit the website melcloud.com
and click Login, Your Language,
Show Demonstration

Wi-Fi Interfaces
MEUK
CLOUD
SERVER

Internet

Wi-Fi Interfaces

*1 MSZ-HJ, VL100 and LGH-RSDC are not connectable to the Internet


*2 M Series and Mr Slim
*3 Ecodan FTC4 system

The Importance of

Controls

M2M
M2M (Machine to Machine) allows air conditioning and ventilation systems as well as third party equipment
to be connected to the Internet via GPRS technology and be monitored and controlled using the web portal
m2m.mitsubishielectric.co.uk. Available in several options for varying applications, M2M can provide
a simple and effective integrated building control system.

M2M Interfaces
For a demonstration of
Mitsubishi Electrics M2M
visit the website:
m2m.mitsubishielectric.co.uk
Login demo
Password demo

MEUK

GPRS

M2M
SERVER

M2M Interfaces

MELCloud vs M2M
FEATURES

MELCLOUD

M2M

Compatible with
Compatible with third party equipment
Internet Connection via
Interface required
Monitor and Control via
Running cost

Air Conditioning and Heating


No
Wi-Fi
MAC-557IF or PAC-WF010
Web portal or App (Smartphone, Tablet)
FOC

Air Conditioning and Ventilation


Yes
GPRS SIM Card
Mini or Maxi M2M
Web portal only
175 per year per interface

Launching this year


We will be launching a
RMI solution (Remote
Monitoring Interface).
RMI (Remote Monitoring
Interface) is an advanced
system which enables monitoring
and control through the Internet via
our centralised controllers (AG-150 and
EB-50). Utilising a web portal, Smartphone
or Tablet App, the system will enable you
to take control of your entire buildings air
conditioning and ventilation systems from
anywhere in the world.

4.5

1.121 Controls

The Importance of Controls

4.6

The Importance of

Controls

The Simpler the Better


With an array of comprehensive control systems available from Mitsubishi Electric,
it becomes simple to design and install air conditioning, heating and ventilation
systems. From a simple hand held controller to an advanced building control
system you are in control.

Optimum Controls for Every Application


Our controls solutions offer systems which can react to different factors and applications. The new PAR-U02MEDA has
an inbuilt occupancy sensor, ideal for providing optimum control of our air conditioning in meeting rooms. The PAR-31MAA
controller not only controls air conditioning, but enables integration with Lossnay ventilation to optimise control and allow
free cooling. In built heating controls through the PAR-W21MAA provide efficient and effective weather compensation.

PAR-31MAA

PAR-U02MEDA

PAR-W21MAA

The Importance of

Controls

The Simpler the Better


A Wide Array of Controls Solutions
Providing control for every size application, the PAC-YT52CRA simplified remote controller is ideal for hotel applications and
the dedicated PZ-60DR enables effective scheduled control of Lossnay ventilation systems, whilst this can be done remotely
for Ecodan heating systems utilising MELCloud and the Wi-Fi interface. At the opposite end, control of an entire buildings air
conditioning, heating and ventilation system can be done through the AG-150A touch screen centralised controller, whilst the
EB-50A offers central control with advanced energy features.
Integrated Control Systems
Enabling our air conditioning, heating and ventilation systems to integrate within the building is critical to optimising
performance and minimising energy consumption. Dedicated interfaces to allow third party companies to monitor and control
via BEMS systems compatible with Modbus, BACnet, Trend and LonWorks are available. The MelcotelTM interface has been
developed especially for hotel applications providing comfortable and effective control in this specialised application.

PAC-YT52CRA

EB-50A

4.7

1.121 Controls

AG-150A

AT-50B

Melcotel

MelcoBEMS

The Importance of Controls

4.8

The Importance of

Controls
Features Key

Non Applicable

Sub

BEMS BACnet

Daily Timer

Web

BEMS Lonworks

Weekly Timer

Refrigerant Volume Check - Web

BEMS RS232

Annual Timer

On/Off Input

BEMS RS485

Night Setback

Fire Alarm

BEMS TCP/IP

Optimised Start

Run Fault Output

BEMS FTT10

Dual Set Point

Interlock Function

Wi-Fi

Setpoint Limit

Key Card

SMS

Temperature Sensor

Energy Saving

GPRS

Backlight

Load Shedding

M2M

Touch Screen

Energy Monitoring

Sim Card Included

CAD

BEMS Trend

Email

MNET

BEMS Modbus

Pulse Meter

The Importance of

Controls
Contents

4.9

1.121 Controls

Controls for Air Conditioning and Ventilation


Remote Controllers
Interfaces
Centralised Controllers
AT-50B Screen Examples
AG-150A Screen Examples
AG-150A Web Screenshots
TG-2000A Screenshots
Energy Monitoring with AG-150A, EB-50A and TG-2000A
How to quote an AG-150A Centralised Controller
How to quote a TG-2000A Software
BEMS Interfaces
How to quote a Modbus Interface
Machine 2 Machine Interfaces
Run Standby Panel
M2M Screenshots

4.13
4.15
4.18
4.21
4.21
4.22
4.22
4.23
4.24
4.25
4.26
4.27
4.28
4.29
4.30

Controls for Heating


Remote Controllers
Interfaces
Centralised Controllers

4.31
4.32
4.33

The Importance of Controls

4.10

Control for
Air Conditioning
and Ventilation
Which Controls
Product for Which
Application?

Good controls will benefit any application. With a wide portfolio of control products,
it is important to select the right control solution for each application.

APPLICATION

SMALL

MEDIuM

LARGE

NOTES

HOTEL

PAC-YT52CRA
AG-150A
AG-150A - Interlock

PAC-YT52CRA
AG-150A
MELCOTELTM

PAC-YT52CRA
AG-150A
MELCOTELTM

A hotel usually requires interfacing with a key card


system and window contact. The MelcotelTM has
been designed to do just this for up to 250 City Multi
indoor units. The MelcotelTM can also work without a
key card system.

OFFICE

PAR-31MAA
PAR-U02MEDA

PAR-31MAA
AG-150A

PAR-31MAA
AG-150A
TG-2000A

In an office application there is usually someone


managing the air conditioning, so the interface needs
to be simple to use. The user friendly AG-150A touch
screen is one option, as well as the TG-2000A PC
graphical user interface.

RETAIL

IO Interface

Mini M2M

AG-150A
Maxi M2M

Retail shops are usually managed by head offices or


facility management companies, so it is key to have
remote monitoring of the air conditioning, but also
any building services which can also be connected
to the M2M interfaces.

LEISURE

PAR-31MAA
PAR-U02MEDA
Mini M2M

PAR-31MAA
AG-150A
Maxi M2M

PAR-31MAA
AG-150A
TG-2000A

In small applications the M2M platform can be a


solution, as well as the AG-150A touch screen or the
TG-2000A software package for larger applications.

EDUCATION

PAR-31MAA
PAR-U02MEDA
Mini M2M

PAR-31MAA
AG-150A
Maxi M2M

PAR-31MAA
AG-150A
TG-2000A

In small applications the M2M platform can be a


solution, as well as the AG-150A touch screen or the
TG-2000A software package for larger applications.

Controls for
Air Conditioning
and Ventilation
Which Controls
Product for Which
Function?

With a wide portfolio of control products, many functions are available.


It is important to select the right control solution for each function.

FuNCTION

LOw

COST AND FEATuRES

HIGH

NOTES

OPTION 1

OPTION 2

OPTION 3

OPTION 4

OPTION 5

Remote On/Off or fire alarm

PAC-SA89TA

TCB1

IO Interface

AT-50B and
PAC-YT51HAA

AG-150A and
PAC-YG10HA

Monitor run and faults

PAC-SA88HA

IO Interface

AT-50B and
PAC-YT51HAA

AG-150A / EB-50A
and PAC-YG10HA

Relays or power supply


may be required

Window interlocking

PAC-SA89TA

TCB1

Controller will be centrally


controlled when window
opened

Setpoint limit

PAR-31MAA

PAR-U02MEDA

AT-50B

AG-150A / EB-50A

AG-150A and
TG-2000A

Available in Heat, Cool


and Auto modes

Weekly timer

PAR-31MAA
PAR-U02MEDA

AT-50B

AG-150A / EB-50A

AG-150A and
TG-2000A

AG-150A and
Maxi M2M

Setpoint, On/Off can


be reset

TCB1

PAR-31MAA
PAR-U02MEDA

AG-150A / EB-50A /
AT-50B

AG-150A and
TG-2000A

AG-150A and
Maxi M2M

TCB1 requires thermostat,


timeswitch, 12v power supply

AG-150A / EB-50A
and
PAC-CN32WHMC-UK

AG-150A and
PAC-YG60MCA

EB-50A and
PAC-YG60MCA

TG-2000A,
AG-150A and
PAC-YG60MCA

M2M

Load shedding

EB-50A and
PAC-YG60MCA

AG-150A and
PAC-YG60MCA

Mini M2M
and A1Ms

AG-150A and
Maxi M2M

Energy meters required

Trend logging

EB-50A and
PAC-YG60MCA

AG-150A and
TG-2000A

Mini M2M
and A1Ms

AG-150A and
Maxi M2M

CSV data available


on a spreadsheet

Night set back


Energy monitoring

On/Off remote controller


button lock except TCB1

Different options for each


choice. Meters required

Notes: The PAC-SA89TA is also known as a 3 wire adaptor and the PAC-SA88HA is also known as a 5 wire adaptor. Disclaimer: These options are for guidance only.

4.11

1.121 Controls

Controls for Air Conditioning and Ventilation

4.12

Controls for
Air Conditioning
and Ventilation
Which Controls
Product for Which
Function?

With a wide portfolio of control products, many functions are available.


It is important to select the right control solution for each function.

FuNCTION

LOw

COST AND FEATuRES

HIGH

NOTES

OPTION 1

OPTION 2

OPTION 3

OPTION 4

OPTION 5

PAC-SA89TA

EB-50A

AG-150A

PAC-SA89TA requires a third


party timer

Ambient tracking

AG-150A and
PAC-YG63MCA

Mini M2M and A1Ms

AG-150A and Maxi


M2M

Option 1 is only available in


cooling mode

Key card interlock


for hotel

AG-150A,
AG-150A-Interlock
and PAC-SA89TA

AG-150A / EB-50A,
MELCOTELTM and
PAC-SA89TA

Volt free contact for


key card normally open

Window sensor interlock for


hotel

AG-150A,
AG-150A-Interlock
and PAC-SA89TA

AG-150A / EB-50A,
MELCOTELTM and
PAC-SA89TA

Volt free contact for window


sensor normally closed

2 setpoints
(1 for cool and 1 for heat)

IO Interface

Mini M2M and A1Ms

AG-150A and
Maxi M2M

For instance, 19C Heat and


23C Cool. Fan only in between

Duty / Standby

PAR-31MAA

PANEL_RS_SMS
and A1Ms

Backup, rotate, join in and


high temperature function

Micro M2M and A1Ms

SIM card not supplied

AG-150A

Mini M2M and A1Ms

AG-150A and
Maxi M2M

PAR-U02MEDA

LOSSNAY-5-FSC

AG-150A and
Maxi M2M

Night mode

A/C faults via SMS


Optimised start
Mini BEMS
Occupancy sensor
Fan Speed CO2 Control

Notes: The PAC-SA89TA is also known as a 3 wire adaptor and the PAC-SA88HA is also known as a 5 wire adaptor. Disclaimer: These options are for guidance only.

Controls for
Air Conditioning
and Ventilation
Remote
Controllers

From a simplified controller perfect for hotel applications to a full backlight touch screen controller,
we have the right remote controller to choose from.

Key Features

Built in temperature sensor

Scheduling

Touch screen and occupancy sensor built in with the PAR-U02MEDA

REMOTE CONTROLLERS

Optional covers available


Backlight available on most of the controllers

PAC-YT52CRA

PAC-YT52CRAS

PAR-u02MEDA

PAR-31MAA

Description

Simplified Remote Controller

Silver Simplified Remote Controller

Touch Remote Controller

Standard Remote Controller

Connect to

Indoor

Indoor

MNET Network

Indoor

16

16

16

16

Compatibility

Mr Slim, City Multi


and M Series
via MAC-397IF

Mr Slim, City Multi


and M Series
via MAC-397IF

City Multi (M Series


and Mr Slim via
A2M adapter)

Mr Slim, City Multi


and M Series
via MAC-397IF

Dimensions (mm) (WxDxH)


Control
On/Off
Mode
Setpoint
Fan Speed
Air Direction
Permit/Prohibit
Filter Sign
Monitor
On/Off
Mode
Setpoint
Fan Speed
Air Direction
Permit/Prohibit
Filter Sign
Fault Codes
Room Temperature
Backlight
Setpoint Limitation
Independent Vane Control
Contact Number under Fault Condition
Scheduling
Night Set Back
Button Lock
Easy Maintenance with Mr Slim
Run / Standby with Mr Slim
Silent Mode with Mr Slim
Energy Saving with Mr Slim
Occupancy Sensor (PIR)

120 x 14.5 x 70

*1
x

*1

x
x
x
x
x
x
x
x
x
x
x

120 x 14.5 x 70

x
*1
x

*1

x
x
x
x
x
x
x
x
x
x
x

140 x 25 x 120

(0.5C)

(0.5C)

(0.5C)

x
x
Weekly

x
x
x
x

120 x 19 x 120

(0.5C)

(0.5C)

(0.5C)

Weekly

Max Number of Units

The new touch screen PAR-U02MEDA remote


controller includes a built in occupancy sensor
which is perfect for meeting room applications

Setpoint limit

Notes: *1 Permit/Prohibit is via Centralised Controllers. *2 The PAC-YT51CRB can only be purchased in conjunction with the BS-51COV-B. = Yes, x = No, - = Not applicable.

4.13

1.121 Controls

Controls for Air Conditioning and Ventilation

4.14

Controls for
Air Conditioning
and Ventilation
Remote
Controllers

From a simplified controller perfect for hotel applications to a full backlight touch screen controller,
we have the right remote controller to choose from.

Key Features

Built in temperature sensor

Scheduling

Optional covers available

Touch screen and occupancy sensor built in with the PAR-U02MEDA

REMOTE CONTROLLERS

Backlight available on most of the controllers

PAR-w21MAA

PAR-FL32MA

PAR-FA32MA

PAR-21PC

PZ-60DR

Description

Standard Remote Controller

Infrared Remote Controller

Infrared Receiver

PC Remote Controller

Lossnay Remote
Controller

Connect to

PWFY
Mr Slim Air Curtains

Indoor

AG-150A and EB-50A

Indoor

Max Number of Units


Compatibility

The PAR-21PC allows you to monitor and


control the air conditioning from your desktop

Setpoint limit

Dimensions (mm) (WxDxH)


Control
On/Off
Mode
Setpoint
Fan Speed
Air Direction
Permit/Prohibit
Filter Sign
Monitor
On/Off
Mode
Setpoint
Fan Speed
Air Direction
Permit/Prohibit
Filter Sign
Fault Codes
Room Temperature
Backlight
Setpoint Limitation
Independent Vane Control
Contact Number under Fault Condition
Scheduling
Night Set Back
Button Lock
Easy Maintenance with Mr Slim
Run / Standby with Mr Slim
Silent Mode with Mr Slim
Energy Saving with Mr Slim
Occupancy Sensor (PIR)

16
City Multi PWFY
Mr Slim Air Curtains

Mr Slim, City Multi and M Series


via MAC-397IF

130 x 19 x 120

x
x
x
x

x
x
x
x

x
x

Weekly
x

x
x
x
x
x

Notes: *1 Permit/Prohibit is via Centralised Controllers.

= Yes, x = No, - = Not applicable.

157 x 18 x 57

x
x

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

16

16

Mr Slim, City Multi and M Series


via MAC-397IF

AG-150A and EB-50A

RX5 Lossnay

120 x 18 x 70
LED
-

x
x

x
x

x
x
x
x
x
x

x
x
x
x
x

130 x 19 x 120

x
x
x

x
x
x

x
x
x
x
x
x
x
x
x
x
x
x
x

Controls for
Air Conditioning
and Ventilation

A wide range of interfaces are available to allow third party equipment to monitor and control our units.
Some interfaces are also available to monitor and control third party equipment from our centralised controllers.

Key Features

Control on/off and monitor run and faults

Energy saving (Auto return mode and dual setpoint)

A control to MNET compatibility

Wi-Fi connectivity

Interfaces
INTERFACES

PAC-SA89TA

PAC-SA89TA

PAC-CN32wHMC

PAC-SA88HA

PAC-SA88HA

PAC-SA88HA

PAC-YT51HAA

Description

On/Off Adapter
(3 wire adaptor)

Pulse Energy
Meter Input

Run and Fault


Adapter
(5 wire adaptor)

Heat and Cool


Adapter
(5 wire adaptor)

Run and Fault


Adapter
(5 wire adaptor)

On/Off Run and


Fault Adapter

Connect to

Indoor

Night Mode and


Demand Control
(3 wire adaptor)
Outdoor

Outdoor

Indoor

Indoor

Outdoor

AT-50B

Max Number of Units


Compatibility

The PAC-SA89TA and PAC-SA88HA


allows simple monitoring and control
using simple signals

Dimensions (mm) (WxDxH)


Control
On/Off
Mode
Setpoint
Fan Speed
Air Direction
Permit/Prohibit
Filter Sign
Monitor
On/Off
Mode
Setpoint
Fan Speed
Air Direction
Permit/Prohibit
Filter Sign
Fault Codes
Room Temperature
Fire Alarm
On/Off but Centrally Controlled
On/Off but NOT Centrally Controlled
Run and Fault Output
Heat and Cool Output
Night Mode and Demand Control
Connect Mr Slim to MNET
Connect Mr Slim to A32M
BAC-A/50

PAC-YG10HA

On/Off Run and MNET Converter


Fault Adapter
(9 wire adaptor)
AG-150A and
EB-50A

Mr Slim and
City Multi

Mr Slim and
City Multi

City Multi

Mr Slim and
City Multi

City Multi

City Multi

AT-50B

AG-150A and
EB-50A

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

VFC
x
x
x
x
-

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

x
x
x
x
VFC
-

x
x
x
x
x
x
x

x
x
x
x
x
x

x
x
x
x
12VDC
x
x
-

x
x
x
x
x
x
x
x

x
x
x
x
x

x
x
x
x
x
12VDC
x
-

x
x
x
x
x
x
x

x
x
x
x
x
x

x
x
x
x
12VDC
x
x
-

x
x
x
x
x
x

x
x
x
x
x
x

VFC
x
Via 24VDC
x
x
-

x
x
x
x
x
x

x
x
x
x
x
x

Via 24VDC
x
Via 24VDC
x
x
-

Notes: VFC: Volt free contact. *1 PUHZ-(ZR)P outdoor type only unit. *2 PAC-SJ19MA / PAC-SK84SI compatible with PUHZ-ZRP35-50. PAC-SF83MA / PAC-SK83SI compatible with all other PUHZ-(ZR)P.

4.15

1.121 Controls

PAC-SJ19MA*2
PAC-SF83MA*2

PAC-SK84SI*2
PAC-SK83SI*2

Mr Slim Adapter

Outdoor

Outdoor

Mr Slim Outdoor Mr Slim Outdoor

130 x 15 x 90
*1
x
x

130 x 15 x 90
x

= Yes, x = No, - = Not applicable.

Controls for Air Conditioning and Ventilation

4.16

Controls for
Air Conditioning
and Ventilation
Interfaces

A wide range of interfaces are available to allow third party equipment to monitor and control our units.
Some interfaces are also available to monitor and control third party equipment from our centralised controllers.

Key Features

Control on/off and monitor run and faults

Energy saving (Auto return mode and dual setpoint)

A control to MNET compatibility

Wi-Fi connectivity

INTERFACES

TCB1

IO INTERFACE

PAC-YG60MCA

PAC-YG63MCA

PAC-YG66DCA

Description

On/Off Adapter

Input / Output
Interface

Pulse Meter
Interface

Temperature
Interface

Third Party
Interface

Connect to

Indoor

Indoor

MNET Network

MNET Network

MNET Network

4 Pulse Meters

1 PT100, 1 Humidity Sensor

2 General Equipment

Compatibility

Mr Slim and
City Multi

M Series and
Mr Slim

AG-150A, EB-50A
and TG-2000A

AG-150A, EB-50A
and TG-2000A

AG-150A, EB-50A
and TG-2000A

Power Supply
Dimensions (mm) (WxDxH)
Control
On/Off
Mode
Setpoint
Fan Speed
Air Direction
Permit/Prohibit
Filter Sign
Monitor
On/Off
Mode
Setpoint
Fan Speed
Air Direction
Permit/Prohibit
Filter Sign
Fault Codes
Room Temperature
On/Off but Centrally Controlled
On/Off but NOT Centrally Controlled
Run Output
Fault Output
Energy Saving
Heat / Cool / Thermo Output
Pulse Weight

12VDC
80 x 45 x 80

x
12VDC
x
x
x
x
x

85 x 32 x 138
VFC
0 to 10VDC
0 to 10VDC
0 to 10VDC
VFC
VFC
VFC
VFC
VFC
VFC
VFC
VFC
VFC
VFC
x

24VDC
200 x 45 x 120
x
x
x
x
x
x
0.1, 1.0 and 10

24VDC
200 x 45 x 120
-

24VDC
200 x 45 x 120

x
x
x
x
x
x

x
x
x
x
x
x

x
-

Max Number of Units

The PAC-YG60MCA allows monitoring


of up to four pulse meters to measure
energy consumptions for instance

Notes: VFC: Volt free contact. = Yes, x = No, - = Not applicable.

Controls for
Air Conditioning
and Ventilation
Interfaces

A wide range of interfaces are available to allow third party equipment to monitor and control our units.
Some interfaces are also available to monitor and control third party equipment from our centralised controllers.

Key Features

Control on/off and monitor run and faults

Energy saving (Auto return mode and dual setpoint)

A control to MNET compatibility

Wi-Fi connectivity

INTERFACES

Description

M Series Adapter

Connect to

Indoor

MAC-333IF

Adapter and MNET Converter


for M Series
Indoor

MAC-557IF

LOSSNAY-5-FSC

DC-5

Wi-Fi Interface

Lossnay Fan Speed Controller

DC Lossnay Fan Speed Controller

Indoor

Indoor

Indoor

Compatibility

M Series and
Mr Slim

M Series and
Mr Slim

M Series and
Mr Slim

Power Supply
Dimensions (mm) (WxDxH)
Control
On/Off
Mode
Setpoint
Fan Speed
Air Direction
Permit/Prohibit
Filter Sign
Monitor
On/Off
Mode
Setpoint
Fan Speed
Air Direction
Permit/Prohibit
Filter Sign
Fault Codes
Room Temperature
On/Off but Centrally Controlled
On/Off but NOT Centrally Controlled
Run Output
Fault Output
Energy Saving
Heat / Cool / Thermo Output
Pulse Weight

160 x 55 x 70

x
x
x
x
x
x

x
x
x
x
x
x

x
x

x
x
x
x
x

160 x 55 x 70

x
x
x
x
x
x

x
x
x
x
x
x

x
x

x
x
x
x
x

88 x 18.5 x 49

x
x

Max Number of Units

MELCloud is a new Cloud solution


for controlling your air conditioning
via the Internet

MAC-397IF

1
RX5 and DC Lossnay

120 x 160 x 80

x
x

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

1
RX5 and DC Lossnay

84 x 55 x 85
x
x
x

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

Notes: VFC: Volt free contact. = Yes, x = No, - = Not applicable.

4.17

1.121 Controls

Controls for Air Conditioning and Ventilation

4.18

Controls for
Air Conditioning
and Ventilation
Centralised
Controllers

A wide range of centralised controllers are available to monitor and control our equipment efficiently.
Some of those centralised controllers may also be used to monitor and control third party equipment.

Key Features
Schedulings

Night set back

CENTRALISED CONTROLLERS

AT-50B

AG-150A

PAC-YG50ECA

EB-50A

Description

5 Touch Screen
Controller

9 Touch Screen
Controller

AG-150A Expansion
Controller

Web Interface

MNET Power Supply

Connect to

MNET Network

MNET Network

MNET Network

MNET Network

MNET Network

Load shedding

50

50

50

50

Compatibility

M Series, Mr Slim
and City Multi

M Series, Mr Slim
and City Multi

M Series, Mr Slim
and City Multi

M Series, Mr Slim
and City Multi

Power Supply
Dimensions (mm) (WxDxH)
Control
On/Off
Mode
Setpoint
Fan Speed
Air Direction
Permit/Prohibit
Filter Sign
Monitor
On/Off
Mode
Setpoint
Fan Speed
Air Direction
Permit/Prohibit
Filter Sign
Fault Codes
Room Temperature
Weekly Schedule
Annual Schedule
Night Set Back
Web Pages
Optimised Start
Automatic Setpoint Adjustment
Load Shedding
Occupied / Unoccupied Settings Reset
Remote Monitoring with M2M
Simple Energy Monitoring
Advanced Energy Monitoring

Via PAC-SC51KUA *1
180 x 30 x 120

x
x
x
x
x
x
x
x

Via PAC-SC51KUA *1
300 x 70 x 185

220-240v, 50Hz
250 x 97 x 266

x
x
x
x

Via PAC-SC51KUA *1
165 x 46 x 120

Max Number of Units

The new EB-50A web based


controller allows full control
of the air conditioning and
ventilation systems with
advanced energy features

Web server capabilities

Notes: *1 Not included in price.

Energy monitoring

PAC-SC51KuA

50
AT-50B, EB-50A
and AG-150A
220-240v, 50Hz
271 x 72 x 169
-

Controls for
Air Conditioning
and Ventilation
Centralised
Controllers

A wide range of centralised controllers are available to monitor and control our equipment efficiently.
Some of those centralised controllers may also be used to monitor and control third party equipment.

Key Features
Schedulings

CENTRALISED CONTROLLERS

Web server capabilities

Load shedding

Energy monitoring

PAC-SF46EPA

MELCOTEL2

MELCOTEL2 DISPLAY

TG-2000A

Description

MNET Booster

AG-150A Hotel
Interface and display

Melcotel2 Display

Software Package

Connect to

MNET Network

AG-150A
and EB-50A

Melcotel2

AG-150A
and EB-50A

Max Number of Units


Compatibility

The new Melcotel2 display allows the


hotel manager to adjust the settings

Night set back

Power Supply
Dimensions (mm) (WxDxH)
Control
On/Off
Mode
Setpoint
Fan Speed
Air Direction
Permit/Prohibit
Filter Sign
Monitor
On/Off
Mode
Setpoint
Fan Speed
Air Direction
Permit/Prohibit
Filter Sign
Fault Codes
Room Temperature
Weekly Schedule
Annual Schedule
Night Set Back
Web Pages
Optimised Start
Automatic Setpoint Adjustment
Load Shedding
Occupied / Unoccupied Settings Reset
Remote Monitoring with M2M
Simple Energy Monitoring
Advanced Energy Monitoring

250

2000

M Series, Mr Slim
and City Multi

City Multi

Melcotel2

M Series, Mr Slim
and City Multi

220-240v, 50Hz
360 x 59 x 340
-

220-240v, 50Hz
350 x 80 x 400

x
x
x
x

x
x
x
x
x

x
x

x
x

x
x

120 x 36 x 107
-

x
x

Notes: *1 Not included in price.

4.19

1.121 Controls

Controls for Air Conditioning and Ventilation

4.20

Controls for
Air Conditioning
and Ventilation
Centralised
Controllers

A wide range of centralised controllers are available to monitor and control our equipment efficiently.
Some of those centralised controllers may also be used to monitor and control third party equipment.

Key Features
Schedulings

Night set back

CENTRALISED CONTROLLERS

AG-150A-BASIC

AG-150A-ENERGY

AG-150A Web
Pin Code

AG-150A Energy
Pin Code

AG-150A

x
x
x
x
x
-

AG-150A and EB-50A


x
x
x

x
x
-

Description
Compatibility
Dimensions (mm) (WxDxH)
Web Pages
Email
Annual Schedule
Energy Monitoring
Energy Saving
Load Shedding
Interlocking
Virtual Remote Controller
Back Box
Wall Mounted Box
Panel
Black Cover

An optional black cover is available


with the AG-150A

CENTRALISED CONTROLLERS

Description
Compatibility
Dimensions (mm) (WxDxH)
Web Pages
Email
Annual Schedule
Energy Monitoring
Energy Saving
Load Shedding
Interlocking
Virtual Remote Controller
Back Box
Wall Mounted Box
Panel
Black Cover

Web server capabilities

Load shedding

AG-150A -INTERLOCK

Energy monitoring

AG-150A-VRC

EB-50A-BASIC

AG-150A Interlock
Pin Code

AG-150A VRC
Pin Code

EB-50A Web
Pin Code

AG-150A and EB-50A


x
x
x
x
x
x

x
-

AG-150A and EB-50A


x
x
x
x
x
x
x

EB-50A

x
x
x
x
x
-

PAC-YG83uTB

PAC-YG81TB

PAC-YG85KTB

PAC-YG71CBL

AG-150A
Back Box

AG-150A Wall
Mounted Box

AG-150A
Panel

AG-150A
Black Cover

AG-150A
346 x 60 x 220

x
x
x

AG-150A
299 x 65 x 184
x

x
x

AG-150A
299 x 101 x 399
x
x

AG-150A
300 x 20 x 175
x
x
x

AT-50B
Screen Examples

AG-150A
Screen Examples

4.21

1.121 Controls

AT-50B Home Screen 3

AT-50B Home Screen 1

AT-50B Home Screen 2

AT-50B Indoor Unit Settings

AT-50B Scheduling

AG-150A Home Screen 1

AG-150A Home Screen 2

AG-150A Home Screen 3

AG-150A Indoor Unit Settings

AG-150A Scheduling

AG-150A Monitoring

Controls for Air Conditioning and Ventilation

4.22

AG-150A
web Screenshots

TG-2000A
Screenshots

Login

Monitor Air Conditioning - Remote Controller

Multiple Users (VRC PIN code)

Monitor Air Conditioning - Overview

Daily, Weekly and Annual Scheduling

Multiple Users (VRC PIN code)

Display Whole Building

Display Floor

Display Block

Remote Controller Settings

Daily, Weekly and Annual Schedule

Energy Monitoring (AG150 Energy PIN code)

Controls for
Air Conditioning
and Ventilation
Energy
Monitoring

Energy Monitoring with AG-150A, EB-50A and TG-2000A


Two options are available with Energy Monitoring:
Simple Energy Monitoring: AG-150A
The AG-150A will allow the customer to monitor energy meter values using the pulse energy meters in conjuction with our
PAC-YG60MCA interface. This will allow the end user to see the energy data on the touch screen or on the webpages.
See How to quote an AG-150A detailed on the following pages.
Advanced Energy Monitoring: EB-50A and TG-2000A
The EB-50A and TG-2000A will allow the customer to monitor energy consumption per zone. This is ideal for multiple
tenants application. The screen will show the energy data per month and this data can also be exported to CSV file.
See How to quote an TG-2000A detailed on the following pages.

4.23

1.121 Controls

AG-150A Touch Screen

EB-50A Web Pages

TG-2000A Software

AG-150A Web Pages

EB-50A Web Pages

TG-2000A Exported Data

Controls for Air Conditioning and Ventilation

4.24

Controls for
Air Conditioning
and Ventilation
AG-150A
Centralised
Controller

How to quote an AG-150A centralised controller

START

SIMPLE ENERGy
MONITORING REqUIRED?

This flow chart goes through each step for


quoting an AG-150A centralised controller
No

qUOTE FOR AG-150A

The AG-150A can monitor and control up to


50 indoor units

qUOTE FOR POWER PACK

The PAC-SC51KUA is required with the AG-150A

BLACK COVER REqUIRED?

An optional black cover is available. The


reference number is PAC-YG71CBL

PLASTIC PANEL REqUIRED?

Two plastic panels are available. The PAC-YG81TB


can only be used for the AG-150A.
The PAC-YG85KTB can be used for the AG-150A
and the power pack

BASIC PIN CODE REqUIRED?

The Basic PIN code activates the following


features: Web, Scheduling and Email

ENERGy PIN CODE REqUIRED?

The Energy PIN code activates the following


features: Energy monitoring, energy saving
and load shedding

Simple energy monitoring allows the AG-150A


to show system energy consumption

Yes
qUOTE FOR PAC-yG60MCA

One PAC-YG60MCA allows up to four pulse


energy meters to be connected to the TG-2000A

SUGGEST MT174
ENERGy METERS

Energy meters are required for energy monitoring.


We would suggest MT174 pulse energy meters

VRC PIN CODE REqUIRED?

END

The VRC PIN code allows multiple users to


connect to the AG-150A webpages

Controls for
Air Conditioning
and Ventilation

How to quote TG-2000A software

This flow chart goes through each


step for quoting a TG-2000A system

START

TG-2000A
Software

No

qUOTE FOR AG-150A


OR EB-50A

The AG-150A would be the first choice


however the EB-50A could reduce cost

qUOTE FOR TG-2000A


SOFTWARE

The software is free of charge


but needs to be quoted

qUOTE FOR
TG-2000A-GRAPHICS

This is an option. We would suggest


one graphic per floor per 30 indoor units

qUOTE FOR COMMISSIONING

ENERGy MONITORING
REqUIRED?

Energy monitoring will allow the software


to break down running cost per zone,
indoor unit or system

SUGGEST PC

One PAC-YG60MCA allows up to


four pulse energy meters to be connected
to the TG-2000A

END

SUGGEST MT174
ENERGy METERS

1.121 Controls

qUOTE FOR AG-150A OR


EB-50A BASIC PIN CODE

VRC PIN CODE REqUIRED?

The Energy PIN code is required


for each AG-150A/EB-50A

The Basic PIN code is free of charge


and allows scheduling on the TG-2000A
The VRC PIN code allows multiple
users to connect to the AG-150A
or EB-50A webpages
Commissioning is required for the TG-2000A.
We would typically commission 100
indoor units per day
We would not supply the PC for
the TG-2000A. Specifications are:
Windows 7 Professional

Yes
qUOTE FOR PAC-yG60MCA

4.25

qUOTE FOR AG-150A OR


EB-50A ENERGy PIN CODE

Energy meters are required for energy


monitoring. We would suggest MT174
pulse energy meters

Controls for Air Conditioning and Ventilation

4.26

Controls for
Air Conditioning
and Ventilation
BEMS
Interfaces

Building Energy Management Systems (BEMS) will allow a building to run efficiently.
A wide range of interfaces are available to connect our systems simply to a BEMS.

Key Features

Modbus, BACnet, LonWorks and Trend compatibility

BEMS INTERFACES

A1M

A32M

BAC-A/50

BAC-HD150

MELCOBEMS

LMAP

IQ3 ExCITE

Description

Splits Modbus
Interface

Mr Slim Modbus
Interface

Mr Slim BACnet
Interface

MNET BACnet
Interface

AG-150A Modbus
BACnet Interface

MNET LonWorks
Interface

AG-150A Trend
Interface

Connect to

Indoor

Outdoor via
PAC-SK83SI

Outdoor via
PAC-SK83SI

MNET

AG-150A and EB-50A

MNET

AG-150A and
EB-50A

Max Number of Units


Compatibility

Power Supply
Dimensions (mm) (WxDxH)
Network
BEMS Compatibility

Control

The new MelcoBEMS is our new


Modbus and BACnet interface for
BEMS solutions

Energy monitoring

Monitor

On/Off
Mode
Setpoint
Fan Speed
Air Direction
Permit/Prohibit
Filter Sign
On/Off
Mode
Setpoint
Fan Speed
Air Direction
Permit/Prohibit
Filter Sign
Fault Codes
Room Temperature
Daily kW Energy
Monthly kW Energy

32

50

M Series and
Mr Slim

Mr Slim

Mr Slim

50

70 x 19 x 50
Modbus RS485

220-240v, 50Hz
270 x 75 x 210
Modbus RS485

220-240v, 50Hz
270 x 65 x 210
BACnet TCP/IP

220-240v, 50Hz
250 x 97 x 266
BACnet TCP/IP

Cylon, Satchwell,
Crestron, Invensys,
Interactive Homes,
North BT, Andover,
Siemens, WEMS, RDM

Cylon, Satchwell,
Crestron, Invensys,
Interactive Homes,
North BT, Andover,
Siemens, WEMS, RDM

Andover Controls, York


BMS, Siemens, Priva
Building Intelligence,
Delta Controls

Andover Controls, York


BMS, Siemens, Priva
Building Intelligence,
Delta Controls

DI
AI
AI
AI
AI
x
DI
DO
AO
AO
AO
AO
x
DO
AO
AO
-

DI
AI
AI
AI
AI
x
DI
DO
AO
AO
AO
AO
x
DO
AO
AO
-

DI
AI
AI
AI
AI
x
DI
DO
AO
AO
AO
AO
x
DO
AO
AO
-

DI
AI
AI
AI
AI
DI
DI
DO
AO
AO
AO
AO
DO
DO
AO
AO
-

M Series, Mr Slim
and City Multi

50

50

50

M Series, Mr Slim
and City Multi

M Series, Mr Slim
and City Multi

M Series, Mr Slim
and City Multi

24VDC
102 x 32 x 180
Modbus / BACnet RS485
and TCP/IP

220-240v, 50Hz
340 x 360 x 60
LonWorks FTT10A

220-240v, 50Hz
263 x 46 x 150
Trend

Cylon, Satchwell, Crestron,


Invensys, Interactive Homes,
North BT, Andover, Siemens,
WEMS, Andover Controls, York
BMS, Siemens, Priva Building
Intelligence, Delta Controls, RDM

Honeywell, Johnson
Controls, Realtime
Control Systems,
Smart Controls

Trend

DI
AI
AI
AI
AI
DI
DI
DO
AO
AO
AO
AO
DO
DO
AO
AO
With EB-50A*1
With EB-50A*1

DI
AI
AI
AI
AI
DI
DI
DO
AO
AO
AO
AO
DO
DO
AO
AO
-

DI
AI
AI
AI
AI
DI
DI
DO
AO
AO
AO
AO
DO
DO
AO
AO
-

From Synapsys*2
Key: DI = Digital Input. DO = Digital Output. AI = Analogue Input. AO = Analogue Output.

*1 The MELCOBEMS can monitor indoor daily and monthly kWh when used in conjunction with EB-50A, PAC-YG60MCA on third party energy meters

Note: The PAC-YG50ECA expansion controller cannot be used with BEMS interfaces.

*2 Synapsys Solutions Ltd, 1 Woodlands Court, Albert Drive, Burgess Hill, West Sussex, RH15 9TN, Telephone 0845 680 0303

Controls for
Air Conditioning
and Ventilation
Modbus

How to quote a Modbus Interface

OPTION 1 (For Splits)


START

qUOTE FOR AN A1M

OPTION 3 (For AG-150A and EB-50A)


This flow chart goes through each
step for quoting a Modbus interface
on a splits system
The A1M is compatible with all splits
manufactured after 2006 except MSZ-HJ
and PEA-RP

END

This flow chart goes through each


step for quoting a Modbus interface
on a PUHZ outdoor system only

qUOTE FOR PUHZ


SUB INTERFACE

A sub interface is required for each outdoor


PAC-SK84SI for PUHZ-ZRP35-50
PAC-SK83SI for all other PUHZ outdoors

qUOTE FOR A32M

The A32M can monitor and control up to


32 PUHZ outdoor units

qUOTE FOR COMMISSIONING

qUOTE FOR AG-150A


OR EB-50A

qUOTE FOR MELCOBEMS

OPTION 2 (For PUHZ outdoor only)


START

START

qUOTE FOR COMMISSIONING

This flow chart goes through each


step for quoting a Modbus interface
with the AG-150A or EB-50A

The AG-150A would be the first choice


however the EB-50A could reduce cost

The MelcoBEMS can monitor and control


up to 50 indoor units

A day commissioning is recommended

END

A day commissioning is recommended

END

4.27

1.121 Controls

Controls for Air Conditioning and Ventilation

4.28

Controls for
Air Conditioning
and Ventilation
Machine
2 Machine
Interfaces
MEUK
M2M
SERVER

M2M (Machine to Machine)


allows air conditioning and
ventilation systems as well as
third party equipment to be
connected to the Internet via
GPRS technology

Machine 2 machine interfaces allows clients to control remotely multiple sites from one location.
Those interfaces may also be used to monitor and control third party equipment.

Key Features
Scheduling

Night set back

Web portal

SMS and GPRS compatibility

MACHINE 2 MACHINE INTERFACES

Load shedding

Energy monitoring

Third party equipment monitoring and control

PANEL_RS_SMS

MICRO M2M

MINI M2M

MAxI M2M

M2M HOSTING

MEUK
M2M
SERVER

Description

Run Stanby Panel

SMS Interface

Splits M2M Interface

AG-150A M2M Interface

One Year M2M Hosting

Connect to

A1M

A1M

A1M

AG-150A and
EB-50A

Max Number of Units


Compatibility

Power Supply
Dimensions (mm) (WxDxH)
SMS Capabilities
GPRS Capabilities
SIM Card Provided
Inputs
Outputs
Control
On/Off
Mode
Setpoint
Fan Speed
Air Direction
Permit/Prohibit
Filter Sign
Monitor
On/Off
Mode
Setpoint
Fan Speed
Air Direction
Permit/Prohibit
Filter Sign
Fault Codes
Room Temperature

16

50

M Series and
Mr Slim

M Series and
Mr Slim

M Series and
Mr Slim

M Series, Mr Slim
and City Multi

M2M

220-240v, 50Hz
253 x 90 x 180

x
x
x
1 Digital (Fault)

x
x
x
x

x
x
x
x

220-240v, 50Hz
70 x 51 x 105

x
x
x
x

x
x
x

x
x
x

220-240v, 50Hz
300 x 75 x 220
x
*1
*1
8 Analogue / Digital
4 Digital

x
x

x
x

220-240v, 50Hz
350 x 80 x 400
x
*1
*1
22 Analogue / Digital
16 Digital

Note: *1 Includes 1 year server hosting and 1 year sim card subscription.
The PAC-YG50ECA expansion controller cannot be used with M2M interfaces.

Controls for
Air Conditioning
and Ventilation

Run Standby PANEL_RS_SMS

Run
Standby
Panel

Example: BACKUP ON, 2, 1, 27 = 2 units running, change daily, high temperature 27C

The panel uses Micro M2M technology. The panel can control up to 8 indoor
units and will send a text message under fault condition. The PANEL_RS_SMS
does not need the SIM card to run.

Unit 1
Day 1

Unit 2

Unit 3

Unit 4
2 units running, unit 3 and 4 are in standby

Day 2

2nd day, the switching over is enabled. Unit 1 and 4


are now in standby and Unit 2 and 3 are running

Day 3

3rd day, the switching over is enabled. Unit 1 and 2


are now in standby and Unit 3 and 4 are running

Day 3

On the 3rd day, the unit 4 fails

Day 3

The next unit in standby starts automatically.


Unit 1 and 3 are running, 2 is in standby and 4 in fault

Day 4

The 4th day, a high temperature is detected for instance 28C

Day 4

All units will then start

Note: The PANEL_RS_SMS is pre-configured as a PANEL_RS1 and can be re-configured as PANEL_RS2 or PANEL_RS3 using a jumper.

4.29

1.121 Controls

Controls for Air Conditioning and Ventilation

4.30

Controls for
Air Conditioning
and Ventilation
M2M Web
Screenshots

Login

Status

Set Parameters

Reports

Controls for
Heating
Remote
Controllers

From a wireless controller to a full backlight hard wired remote controller, we have the right remote
controller to choose from.

Key Features

Built in temperature sensor

Holiday mode

Scheduling

Advanced weather compensation

Two zone control

Intelligent room temperature control

REMOTE CONTROLLERS

PAC-IF052B-E

PAR-wT50R-E

PAR-wR51R-E

Description

Flow Temperature Controller 4

Wireless Remote Controller Transmitter

Wireless Remote Controller Receiver

Connect to

Ecodan PUHZ

FTC4

Max Number of Units

The FTC4 controller for


Ecodan PUHZ models

Ecodan PUHZ

Ecodan PUHZ

Ecodan PUHZ

Dimensions (mm) (WxDxH)


Control
On/Off
Mode
Setpoint
Fan Speed
Air Direction
Permit/Prohibit
Filter Sign
Monitor
On/Off
Mode
Setpoint
Fan Speed
Air Direction
Permit/Prohibit
Filter Sign
Fault Codes
Room Temperature

120 x 19 x 120

x
x
x
x

x
x
x
x

140 x 18 x 75
x

x
x
x
x

x
x
x
x
x

100 x 30 x 80

x
x
x
x

x
x
x
x

Notes: = Yes, x = No, - = Not applicable.

4.31

1.121 Controls

Compatibility

Controls for Heating

4.32

Controls
for Heating
Interfaces

A wide range of interfaces are available to allow third party equipment to monitor and control
our units. Some interfaces are also available to monitor and control third party equipment from
our centralised controllers.

Key Features

Wi-Fi connectivity

INTERFACES

Description

Wi-Fi Interface

Connect to

Indoor

Max Number of Units

MELCloud is a new Cloud solution


for controlling your Ecodan via the
Internet. Please refer to the Heating
section for further information

PAC-wF010-E

Compatibility

Ecodan FTC4

Power Supply
Dimensions (mm) (WxDxH)
Control
On/Off
Mode
Setpoint
Fan Speed
Air Direction
Permit/Prohibit
Filter Sign
Monitor
On/Off
Mode
Setpoint
Fan Speed
Air Direction
Permit/Prohibit
Filter Sign
Fault Codes
Water Temperature

88 x 18.5 x 49

x
x
x
x

x
x
x
x

Notes: = Yes, x = No, - = Not applicable.

Controls
for Heating
Centralised
Controllers

A wide range of centralised controllers are available to monitor and control our equipment efficiently.

Key Features
Schedulings

CENTRALISED CONTROLLERS

Web server capabilities

AG-150A

PAC-SC51KuA

Description

9 Touch Screen
Controller

MNET Power Supply

Connect to

MNET Network

MNET Network

Max Number of Units


Compatibility

The Ecodan CAHV is now compatible


with the AG-150A centralised controller

Night set back

Power Supply
Dimensions (mm) (WxDxH)
Control
On/Off
Mode
Setpoint
Fan Speed
Air Direction
Permit/Prohibit
Filter Sign
Monitor
On/Off
Mode
Setpoint
Fan Speed
Air Direction
Permit/Prohibit
Filter Sign
Fault Codes
Water Temperature
Weekly Schedule
Annual Schedule
Night Set Back
Web Pages

50

50

Ecodan CAHV

AG-150A

Via PAC-SC51KUA *1
300 x 70 x 185

x
x

x
x

220-240v, 50Hz
271 x 72 x 169
-

Notes: *1 Not included in price.

4.33

1.121 Controls

Controls for Heating

Services

Services

Services

At Mitsubishi Electric, not only have we developed an innovative range of air conditioning,
heating, ventilation and control solutions, we have also examined how we support the
market throughout the complete lifecycle of our products - literally from cradle to grave.

at every step of the way

Whether in pre-sales design and specification, installation and maintenance support, right through to
our free recycling programme, we can offer solutions that deliver the quality and excellence you would
expect to help make a world of difference.

Contents

MeLSmart Technical Services

5.4

Partner Programme

5.8

and Support

5.3

1.121 Services

Design and consulting Services

5.10

MeLFinance Solutions

5.11

Deliveries

5.12

cPD Accreditation

5.13

Website and Document Library

5.13

ServiceS

Services and Support at Every Step of the Way

5.4

Services

Advanced, reliable technical support at every step of the way

at every step of the way

Meeting todays energy challenges for our commercial premises demands more integrated
thinking from everyone involved in the design, supply, installation, commissioning and maintenance
of essential building services - whether it is for an individual property or a national estate.

and Support

MELSmart Technical Services

Ever increasing energy bills, the need to reduce carbon emissions and a raft of challenging legislation are driving the demand
for increased energy efficiency and control in the cooling, heating, ventilation and associated technologies that we use.
As a manufacturer, we realise that product development alone is not enough.
To keep our products working at their optimum, we have developed the MELSmart approach to ensure our customers
are able to maximise the energy efficiency of their buildings services right from the start.

MeLSmart offers a range of support that includes:


24/7/365 Technical Help Desk

Maintenance and System Health Checks

Fault Finding

CPD Accredited Product Training

Commissioning

Trouble Shooting

Spare Parts & Warranty

R22 Audit Surveys

Whatever the challenge, were here to help you meet it.

MeLSmart contact Details:


Telephone: 0161 866 6089
Option 1 - Air Conditioning Technical
Option 2 - Spares
Option 3 - Warranty
Option 4 - Heating Technical
Option 5 - Returns
Option 6 - Product Training and Site Services

Services
and Support
at every step of the way

Product Training
Mitsubishi Electric has six state-of-the-art training suites based at Hatfield, Birmingham, Bristol, Manchester,
Scotland and Reigate for your convenience. Providing product training for all levels of expertise, our courses
are taught by experienced engineers, with a wealth of knowledge and are all CPD accredited.
For bookings please telephone 0161 866 6089 (Option 6, Option 1)
Product Range

CouRSE

REfEREnCE

City Multi

Design and Application

CMDA

City Multi

Commissioning and Set Up

CMPT1

City Multi

Service and Fault Finding

CMPT2

Installation, Service and Fault Finding

MPISF

Controls

Module 1

CTM1

Controls

Module 2

CTM2

Controls

Module 3

CTM3

Ecodan

Design and Application Part 1

ED&A11

Ecodan

Installation and Commissioning Part 2

EI&C11

Ecodan

Service and Fault Finding Part 3

ES&FF11

Ecodan

Non Domestic Heating Design & Application

NDHDA

M Series and Mr Slim

5.5

1.121 Services

ServiceS

MELSmart Technical Services

Services
and Support
at every step of the way

5.6

Commissioning
Prior to operation, the MELSmart team ensures that the installation is checked against design specification.
Trained technicians ensure that the system is fully operational, and that performance and energy efficiency
is maximised.
We then confirm whether or not the system is operating within its design parameters and validate any warranties.
All on-site equipment is then added to our database where a constant record will be kept of any activities between
the site and Mitsubishi Electric. On completion, we will provide a Commissioning Log Book with an accurate
operating record of the working system.
Type of Visit

PRiCE

Fault Diagnostic Site Visit

Please contact Mitsubishi Electric

Commissioning (as per commissioning check list)

Please contact Mitsubishi Electric

City Multi Strip Down


Controls Commissioning

See next page


Please contact Mitsubishi Electric

For Controls Commissioning, forms will need to be completed prior to the site visit. Please contact: 0161 866 6089 (Option 6, Option 2)

Design

PRiCE

Post-Installation Appraisal / Evaluation

Please contact Mitsubishi Electric

Health Checks

Please contact Mitsubishi Electric

Services
and Support
at every step of the way

City Multi Stripdown


For installations where the City Multi outdoor unit(s) cannot be moved to the final location, Mitsubishi Electric
offer a City Multi strip down service.
Type of Visit

uniT naME
PUHY-P200YJM
PUHY-P250YJM
PUHY-P300YJM

PUHY-EP200YKM
PURY-P200YJM
PURY-P250YJM

PURY-P300YJM

PUHY-P350YJM
PUHY-P400YJM
PUHY-EP250YKM

PURY-P350YJM
PURY-P400YJM
PURY-EP200YKM

PURY-EP250YKM

PFD-P250VM

PFD-P500VM

5.7

1.121 Services

PUHY-P450YJM
PUHY-EP300YKM
PURY-EP300YKM

PURY-EP350YKM

PQHY-P200YHM
PQHY-P250YHM
PQHY-P300YHM

PQRY-P200YHM
PQRY-P250YHM
PQRY-P300YHM

ServiceS

MELSmart Technical Services

5.8

Services
and Support
at every step of the way

Mitsubishi Electric Partner Programme


The Mitsubishi Electric Partner Programme is inclusive and open to all qualifying air conditioning
and heating installation companies, large or small.
Using the world-renowned Mitsubishi Electric brand, we will train, facilitate and promote all qualifying companies as part of our aim to drive
the industry forwards. Mitsubishi Electric recognises the importance of forging lasting relationships with professional companies who install
our equipment. Our Partner Programme enables us to do just that.
Established since 2005 and designed to raise industry standards, our Partner Programme assures end users of a consistently
high level of installation and after sales service that supports our systems. To be eligible to join our scheme in the first instance,
prospective installation partners must comply with the necessary building regulations and meet specific industry,
programme and CSR standards.
All partners are reviewed on a regular basis to ensure they continue to meet the required standards
that makes them eligible to be part of the Mitsubishi Electric Partner Programme.

How to apply for the Partner Programme


Speak to your Mitsubishi Electric Representative
or email partner@meuk.mee.com

Services
and Support
at every step of the way

Partner Programme Benefits


Dedicated Partner Programme Co-ordinator
Our dedicated Partner Programme Co-ordinators are on hand to give Partners the support they need.

Joint Marketing / Relationship Development Fund (RDF)


We will work with Partners to promote our relationship and generate awareness of the unique business benefits of the Partner Programme
to end-users. We operate a Partner Programme Relationship Development Fund (RDF) allocated in relation to their commercial activities
with Mitsubishi Electric.

Promotional Goods RDF Catalogue


Partners can take advantage of their RDF to enhance their company image with dual branded work wear, promotional items
and golf accessories.

Product and Industry Training


Although our Partners receive a free allocation of training courses, additional courses can be funded from the
Relationship Development Fund at no further cost to the Partner.

24hr Technical Support


To assist our Partners in the maintenance of our equipment we have a dedicated technical support team who will endeavour to speedily
diagnose faults and offer solutions to the problems our Partners may encounter.

Extended Warranty
We will offer all Partners who adhere to our standards exclusive extended warranties.

Sales Leads
We will make sales leads available exclusively to our Partners.

Business Support Tools


We have made it easier to do business with Mitsubishi Electric through the
introduction of new technologies and our business tools available to Partners.

Factory Visits & Events


Our Partners and their clients will have the opportunity to witness first-hand
the manufacture of air conditioning and Ecodan units at our manufacturing
facility in Scotland.

5.9

1.121 Services

ServiceS

Partner Programme

5.10

Services
and Support
at every step of the way

Design and Consulting Services


As part of the Mitsubishi Electric commitment to supporting robust application of our leading
technologies, a team of Consultant Sales professionals work nationally with mechanical building
services specifiers and consultants to achieve early engagement in project design.
Clients are able to confidently apply cooling, heating, ventilation and controls within their individual projects with the
emphasis on a solution-based philosophy to support as-designed performance and efficiencies.
This approach helps projects realise as-specified performance and efficiency levels - all designed to achieve the most
efficient and cost-effective outcome for the building operator, whilst reducing the overall environmental impact.
As initial designs move from the drawing board through planning, procurement, installation and commissioning, to on-going
operation and use, we work closely with our customers to balance capital expenditure, system efficiencies, installation costs,
control strategies and running costs.

Working in the real world


Recognising the commercial and delivery pressures of projects in the real world Mitsubishi Electric
has in place a number of technically biased Business Development Managers.
Our team support the M&E roll out and tackle the challenges associated with change of building use or layout (design evolution)
from original design and to support robust value engineering that does not compromise the original design or performance criteria.
We understand the link between effective design and achieving the best outcomes for built environment owners, operators
and users. The goal of our team is therefore to ensure robust design and to support an equally robust implementation.
Getting the right balance between capital cost, system efficiencies, installation costs, control systems and ultimately
operating costs all need to be considered at an early stage to ensure a positive outcome.
Framing and enabling the market-leading service we offer our clients is the on-going professional and personal development
of our employees to meet ever increasing customer needs in product knowledge, industry practice and legislation.

Services
and Support
at every step of the way

Mitsubishi Electric MELFinance Solutions


Mitsubishi Electric Living Environmental Systems developed MELFinance Solutions to respond to
current market conditions and the need for customers to manage cash flow, while benefitting from
the installation of leading technology to reduce carbon emissions and operational costs.
MELFinance Solutions can help end user customers fund the cost of new equipment and its installation via hire-purchase finance. Put simply,
this means that (subject to financial status), an end-user customer can repay the combination of 'fixed asset' and maintenance costs over an
agreed period of between 1 to 5 years. For qualifying companies, it is a flexible alternative to a traditional bank loan that provides significant
cash flow and tax benefits:

No need for hefty deposits

Finance deals are secured wholly or largely on the heating, cooling and/or ventilation equipment being financed

Stronger cash flow

Releases tied-up cash and preserves other forms of credit for other business or operational needs

Fixed, regular payments

Helps you plan for the future by eliminating uncertainty and costly surprises

Quick decisions

We always aim to provide a prompt turnaround for funding applications

immediate payment

Settlement of the full installation and equipment invoice upon installation/delivery


The five-year, "trouble-free" cooling, heating and ventilation finance package offers a host of advantages integrating on-site installation and
commissioning fees, minimum three-year warranty on all Mitsubishi Electric equipment, scheduled maintenance visits and 24/7 emergency
technical helpline for any on-site issues.

To get your no obligation finance proposal visit: www.MeLFinanceSolutions.co.uk


or email MeLFinanceSolutions@meuk.mee.com
Mitsubishi Electric Europe B.V. holds a Consumer Credit Licence no. 0658891 for credit brokerage. As from 1 April 2014: Authorised and regulated by the Financial Conduct Authority as a credit broker.
Hire-purchase finance will be considered subject to status by an independent finance house as facilitated by Mitsubishi Electric. Finance house's terms and conditions apply. This website text does not constitute an offer to supply
goods/services or provide or arrange hire-purchase finance. Finance only available where you enter into Mitsubishi Electric's contract package for removal of any existing installation, design, supply and commissioning services.
Package is conditional on you entering into (i) a maintenance contract for the installation and (ii) a hire-purchase agreement with Mitsubishi Electric's finance partner. Otherwise, all goods are supplied subject to Company's
General Terms and Conditions of sale, copy available upon request.

5.11

1.121 Services

ServiceS

Design and Consulting Services


MELfinance Solutions

5.12

Services
and Support
at every step of the way

Mitsubishi Electric Deliveries


At Mitsubishi Electric, we take our delivery programme very seriously because we realise that
our customers businesses can depend on getting the right equipment on site at the right time.
Thats why we have developed a comprehensive and flexible delivery programme with one of the longest delivery windows in the industry.
With the ability to offer timed, weekend and Public Holiday deliveries, coupled with free Text Ahead and Ring Ahead functions, we aim
to keep our customers informed every step of the way.

Delivery Notes
Cut off for next day deliveries is 2.30pm on the working day prior to delivery
Standard delivery is between 8.00am and 5.30pm
AM / PM / Timed / Weekend / Public Holiday deliveries are all available (additional notice needed and charges will apply
- please refer to full delivery guidelines for further details)
Standard delivery will normally be made on an 18T rigid lorry equipped with a tail lift and a single driver with a pump truck
Other vehicle types will be utilised dependant on any site access issues and delivery size
If there are access restrictions at your nominated delivery point and a vehicle other than an 18T lorry is required, this will need
to be booked in advance and a charge may apply
Our Text Ahead and Ring Ahead functions are available on all deliveries with the exception of parcel providers,
which will offer Text Ahead only
Deliveries available via HIAB (Flatbed vehicle with crane) / with chapter 8 signage - require 48 hours notice and
extra charges may apply
We offer a 2-man delivery service, removal of packaging and a stair walker - these require 48 hours notice and
extra charges will apply
Mitsubishi Electric is an Associate Member of the Fleet Operator Recognition Scheme (FORS) and all of our vehicles are
FORS accredited to Bronze level
Collection is also available from our Milton Keynes warehouse - these must be pre-arranged and require at least 3 hours notice
Returns to be notified within 15 working days - Terms and Conditions apply
For further information on our recycling service please refer to the website recycling.mitsubishielectric.co.uk

Services
and Support
at every step of the way

CPD Information Guides


Mitsubishi Electric is accredited by the Construction CPD Certification Service in many different areas.
We have produced a number of Industry Information Guides that are available to download from our document library.
We also run a number of CPD seminars and training courses across the UK.

To find out more, simply contact your local Mitsubishi Electric sales office.

Mitsubishi Electric Website and Document Library


Website
For further information on any of our products and services please visit our Living Environmental Systems website,
livingenvironmentalsystems.mitsubishielectric.co.uk which has been designed to provide a detailed overview of the
energy saving solutions we can provide you.
The smart, clean and modern design of the site focuses on the features and benefits that Mitsubishi Electric equipment has to offer and
hosts new Air Conditioning, Heating, Corporate Solutions and Green Gateway websites under one umbrella, making it easy for visitors to
navigate between them. The websites not only promote our comprehensive product offerings but have also been designed to inform and
educate visitors, with pages dedicated to the very latest legislative challenges that face all those involved in the built environment.

Document Library
The website also includes a comprehensive Document Library which features all current operating and installation
manuals, as well as product literature, CPD guides and more.
This means there is no longer a requirement for visitors to login to our sites to download the latest product and technical
information. To add to this, a document library app will be launched soon allowing visitors to access this information simply
from their tablet or smart phone.

5.13

1.121 Services

ServiceS

Deliveries / CPD information Guides /


Website and Document Library

2014 Product Catalogue

Living Environmental Systems


2014 Product Catalogue

Sales Contacts

London North Region

Corporate Sales

Birmingham

Bristol

Leeds

Tel: 0870 3000 070


Fax: 0870 3000 080

Tel: 0121 741 2800


Fax: 0121 741 2801

Tel: 01454 202050


Fax: 01454 202900

Tel: 01924 207680


Fax: 01924 207 699

Tel: 01707 282480


Fax: 01707 282481

London Central Region

London South Region

Manchester

Scotland

Ireland

Tel: 0207 928 6810


Fax: 0207 928 6569

Tel: 01737 387170


Fax: 01737 387189

Tel: 0161 866 6060


Fax: 0161 866 6081

Tel: 01506 444960


Fax: 01506 444961

Tel: +353 (0)1 419 8800


Fax: +353 (0)1 419 8890

Telephone: 01707 282880


MELSmart Technical Services: 0161 866 6089
Technical Help - option 4
Warranty - option 3
Training - option 6 followed by option 1
email: livingenvironmentalsystems@meuk.mee.com
website: livingenvironmentalsystems.mitsubishielectric.co.uk
website: recycling.mitsubishielectric.co.uk
UNITED KINGDOM Mitsubishi Electric Europe Living Environmental Systems Division
Travellers Lane, Hatfield, Hertfordshire, AL10 8XB, England
General Enquiries Telephone: 01707 282880 Fax: 01707 278881

IRELAND Mitsubishi Electric Europe Westgate Business Park, Ballymount, Dublin 24, Ireland
Telephone: Dublin (01) 419 8800 Fax: Dublin (01) 419 8890 International code: (003531)
Country of origin: United Kingdom Japan Thailand Malaysia. Mitsubishi Electric Europe 2014. Mitsubishi and Mitsubishi Electric are trademarks of Mitsubishi Electric Europe B.V. The company reserves the right to make any variation
in technical specification to the equipment described, or to withdraw or replace products without prior notification or public announcement. Mitsubishi Electric is constantly developing and improving its products. All descriptions, illustrations,
drawings and specifications in this publication present only general particulars and shall not form part of any contract. All goods are supplied subject to the Companys General Conditions of Sale, a copy of which is available on request.
Third-party product and brand names may be trademarks or registered trademarks of their respective owners.
Note: The fuse rating is for guidance only. Please refer to the relevant databook for detailed specification. It is the responsibility of a qualified electrician/electrical engineer to select the correct cable size and fuse rating based on current regulation
and site specific conditions.

Printed in April 2014