Spector Lumenex

Literature Sheet
PML/0017a

Systems

Adaptable Communications Engine


(ACE)
ACE is a generic term given to a high integrity voice and alarm
broadcast package. There are three ACE management node options
available each facilitating efficient secure public address and alarm
system control and supervision.

There are three ACE management node options available: ACE4, ACE16, ACE100.

FEATURE
MAXIMUM # OF ACET SOURCE

ACE 4

ACE 16

ACE 100

4 (see note 1)

13 (see note 2)

48

MAXIMUM # OF BROADCAST ZONES


TELEPHONE INTERFACE
TICK TONE (ZONABLE)
TEST MICROPHONE INPUT
ALARM TONES
DIGITALLY STORED MESSAGES
BACKGROUND MUSIC INPUT
MULTI SPEECH PATH
MAXIMUM AUDIO POWER OUTPUT
SUPERVISORY
INPUT SURVEY AUDIO ROUTE
INPUT SURVEY CONTROL ROUTE

4
Yes (see note 3)
Yes
No
4
See note 12
Yes
No
400 watts
Yes
DTMF
Timed

8
Yes
Yes
Yes
4
See note 12
Limited
No
unlimited
Yes
DTMF
Timed

AMPLIFIER OUTPUT/LINE SURVEY

20k/ End of line

20k/ End of line and


current monitoring

Yes

Yes

48
Yes
Yes
No
Yes
Yes
Yes
Yes
14.4KW
Yes
DTMF
Error detection
20k/ End of line,
current monitoring
and LTU
Yes

Yes

Yes

Yes

No

Yes

Yes

No
Yes (see note 4)
2
No
No
No

8
Yes (see note 5)
2
Yes
Yes
No

8
Yes
Up to 64
Yes
Yes
Yes

INPUTS

LINE INSULATION TEST


SUPERVISORY URGENT/NON URGENT
FAULT CONTACTS

SUPERVISORY RS232 SERIAL


OUTPUT

AUXILIARY FAULT INPUTS


BEACON CONTROL OUTPUT
NUMBER OF CONTROL OUTPUTS
BEACON LINE SUPERVISION OPTION
SABS ADDRESSABLE BEACONS
SALS ADDRESSABLE LOUDSPEAKERS

Morley Avenue
Mapperley
Nottingham
NG3 5FW
England

Tel: +44 (0) 115 955 11 99


Fax: +44 (0) 115 955 19 19
E-Mail: tfis.voice.uk@tycoint.com
http: www.tycofis.co.uk

tyco
Fire & Integrated
Solutions

FEATURE
AMPIID RANGE POWER
AMPLIFIERS

A1 SIL
A2 SIL
B1V SIL
B2 SIL
C SIL
ENTERTAINMENT MUTE OUTPUT
CONTACT

AUTOMATIC ALARM INITIATION


QUALITY OF AUTO ALARM INPUTS
DUAL A/B SYSTEM
CONFIGURATION

ALARM SYNC. CABLE


NETWORKABLE SITE WIDE
MAXIMUM NUMBER OF SITE WIDE
AMPLIFIER LINE VOLTAGE
BATTERY BACKUP OPTION
BATTERY AUTONOMY
LOUDSPEAKER MUTING
MAINS SUPPLY AC
MAINS SUPPLY D.C.
RECONFIGURABLE
REMOTE CONFIGURATION
INITIALLY SAFE ZONE 1 ACET
ACCESS UNITS

FAULT SOUNDER

ACE 4

ACE 16

ACE 100

No

Yes

Yes

No
No
No
No
No

Yes
No
Yes
Yes
No

No
Yes
Yes
Yes
Yes

No

Yes

Yes

Yes
Yes

Yes
Yes

Yes
Yes

Up to 64

Yes
No
Limited
100v (70v)
(see note 6)
Yes
24 hour/ 1/2 hour or
3 hours (see note 7)
4
110/120v AC 50/60Hz
220/240v AC 50/60Hz
24v DC
48v DC (see note 8)
By chip exchange
No

Yes
No
Limited

Yes
Yes
Yes

100v (70v)

100v (70v)

Yes
Custom to system
design
13
110/120v AC 50/60Hz
220/240v AC 50/60Hz
24v DC (see note 9)
48v DC
By chip exchange
No

Yes

Yes (See Note 10)

Yes

Yes

Yes (See Note 11)

Yes

Yes

Custom to system design


Up to 64
110/120v AC 50/60Hz
220/240v AC 50/60Hz
24v DC (see note 9)
48v DC
By download from PC
Yes

Notes
(1)

The ACE4 node has four inputs:


Input 1
ACET/18/NK or ACETS01
2
ACET/18/NK or ACETS01
3
ACETS01
4
ACETSO1 or CCU telephone
interface
(2) The ACE16 node has thirteen inputs:
Input 1
ACET/18/NK or ACETS01
2
ACET/18/NK or ACETS01
3
ACET/18/NK or ACETS01
4
ACET/18/NK or ACETS01
5
ACET/18/NK or ACETS01
6
ACET/18/NK or ACETS01
7
ACETS01
8
ACETS01
9
ACETS01
10 ACETS01
11 ACETS01
12 ACETS01
13 ACETS01
(3) A CCU/telephone interface engages an
input of the ACE 4 usually input #4.
(4)
Up to a maximum of five 24v DC LAK6
beacon capable of being driven by each beacon
control
output.

(5)

Up to a maximum of five AC/DC LAK beacon


capable of being driven by each beacon
control output. Note: there are four output
sets per control output i.e. total of 20
beacon per control output. Further output
sets is increments of four per beacon
control outputs are possible by additional
ACE/408/CON.
(6) 100v line standard 70v line optional
(7) 24
hours
quiescent
30
minutes
alarm/speech OR 30 minutes down 30
minutes speech 2 hours quiescent further
battery autonomy to order.
(8) ACE4 48v DC mains supply to order
(9) 24v DC mains supply use AMPIID/24/150
amplifier module.
Note (8) & (9) DC supply floating OR
negative earth positive earth to order.
(10) ACE4 supports only ACETS01 in hazardous
area zone 1 execution
(11) Fault sounder is located in the node only.
Sounder is silenced by non-locking
acknowledge button also located on the
respective node.
(12) Enquire for details.

Tyco Fire & Integrated Solutions have a policy of continuous product improvement, therefore this information is subject to change without notice.
Copyright. This publication is the property of Tyco Fire & Integrated Solutions. It may not be copied or transmitted without the express written permission of Tyco Fire & Integrated Solutions.