Installation Manual
Series DFT
Proportional
DC-Valve
Contents
Proportional DC Valve
Series DFT
Installation Manual
Note
This document and other information from Parker Hannifin GmbH, its subsidiaries,
sales offices and authorized distributors provide product or system options for
further investigation by users having technical expertise. Before you select or use
any product or system it is important that you analyse all aspects of your
application and review the information concerning the product or system in the
current product catalogue. Due to the variety of operating conditions and
applications for these products or systems, the user, through his own analysis and
testing, is solely responsible for making the final selection of the products and
systems and assuring that all performance and safety requirements of the
application are met. The products are subject to change by Parker Hannifin GmbH
at any time without notice.
Hydraulics
Home
Proportional DC Valve
Series DFT
Installation Manual
Function Description
The integrated valve electronics include the following
functions:
Differential command input for voltage or current
signals
Adjustable ramp generator
Flow offset adjustment (MIN) and deadband
compensation
Maximum adjustment (MAX) to maintain full
use of the command signal range over the
actual flow spectrum set with this adjustment
Pulse width modulated current signals for both
valve solenoids
Standard central connection socket
There is a linear relationship between the solenoid
current and the input signal. The solenoid current is
stabilised against voltage fluctuations as well as
temperature dependent resistance variations of the
solenoid coils. Because of the effect of load on the
position of the valve spool, the spool position can
vary and there is a limited relationship between the
input signal and the valve flow.
Type-code Extract
EMC
EN 50081-2
EN 50082-2
EN 55011
ENV 50140
ENV 50204
EN 61000-4-2
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
Electrical Specification
Supply Voltage
Range
14.5...30VDC
max. 5%
Current Consumption
max. 2.8A
Input Signal
Voltage Input
0...+/-10V / 100KOhm
Range
Current Input
0...+/-20mA / 500Ohm
Reference Output
0...3 seconds
-20...+60C
Cabling Cross-section
Leads Length
max. 50m
60V = / 16A
5004072
5004091
*max. 30VDC against pin G (ground)
Hydraulics
Home
Proportional DC Valve
Series DFT
Installation Manual
Block Diagram of the Electronics
Connection
Hydraulics
Home
Proportional DC Valve
Series DFT
Installation Manual
Function diagram
Standard configuration
Model
command
signal polarity
flow
direction
interruption
between
contact pins
effect:
interruption of
the flow
from ... to ...
P-A
B and A
P- A
P-B
B and D
P-B
P-B
B and A
P-A
P-A
B and D
P-B
P-B
B and A
P-A
P-A
B and D
P-B
Potentiometer
D1FT
D31FT
D41FT
D81FT
D91FT
P4 (Ramp B)
+ on
+ off
P1 (Ramp A)
- off
- on
Hydraulics
Home
Proportional DC Valve
Series DFT
Installation Manual
MIN-/MAX Setup
Set-up procedure:
1) Feed in a command signal of +200mV (resp. +
0.4mA) at the input D.
2) Adjust offset for corresponding valve side by
potentiometer "MIN B".
3) Feed in a command signal + 10V (resp. +
20mA) at the input D.
4) Adjust the required spool stroke (required flow)
for corresponding valve side by potentiometer
"MAX B".
5) Repeat this procedure for opposite valve side.
Feed in negative command signals and adjust
by using potentiometers "MIN A" and "MAX A".
6) Take into account that MIN has to be adjusted
before MAX.
7) See function diagram.
Mechanical Arrangement of the Electronics
Hydraulics
Home
Proportional DC Valve
Series DFT
Installation Manual
( 2.5 Amp.)
( 5.0 Amp.)
(10.0 Amp.)
Relais and solenoids operating from the same supply circuit as the valve electronics has to be fitted by
surge protection elements.
Wiring Cable
The wiring cable between the control cabinet and the valve has to be shielded. The central wiring has to
be installed from a 7 wire cable that utilizes a common shielding and a cross section of min. AWG17. For
the connection of the option "Solenoid disable / Supervisory output" a similar cable has to be used. The
capacity should not exceed a value of approx. 130 pF/m (wire/wire). The maximum cable length is 50 m.
No power current lines may be placed in parallel to the valve's wiring cables. The cable shield has to be
connected to earth ground at both ends (see also chapter "Grounding"). Please be aware of g round loops.
Connectors
The central connection of the valve electronics needs a connector 6pin+E according DIN 43563 featuring
metal case and integrated cable shield coupling. Use a similar connector 5pin for the connection of the
optional "Solenoid disable / Supervisory output" function. Parker can provide suitable connectors:
5004072
5004091
(Connector 6pin+E)
(Connector 5pin)
The connectors has to be installed according the connection diagram, the cable shield has to be tied on
the whole periphery to the provided coupling clamp.
Grounding
The mounting plate of the valve has to be connected to the grounded metal machine frame. The earth wire
to pin G of the central wire cable as well as the cable shields of the valve connection cables should be
tied to earth ground at the control cabinet. A low-ohmic potential compensation wire has to be provided
between the control cabinet and the machine frame (cable wire AWG7 cross section) to prevent ground
loops.
Hydraulics
Home
Proportional DC Valve
Series DFT
Installation Manual
Hydraulics
Home