Professional Documents
Culture Documents
Gas Dryer
Model : KUD-WG33S
JUL. 2008
Contents
What is a Dryer? .....................................................................................................2
Dryer Specification..................................................................................................4
Operating Mechanism Diagram (Gas Type) .........................................................5
Mechanism by Assy (Gas Type)....................... ....................................................6
Parts List by Assy...................................................................................................7
Procedure for Reversing the Door........................................................................18
PCB Function Specification...................................................................................19
Gas Dryer PCB Pin ...............................................................................................31
Drum Dryer Troubleshooter ..................................................................................32
Gas Dryer Wiring Diagrams...............................................................................33
Dryer Installation .. ...................................................... ..........................................35
Dryer Service Notices ...........................................................................................36
Electric Parts List - Gas Clothes Dryer..................................................................37
Thermostat Fan ....................................................................................................49
Lamp Assembly..................................................................................................50
Switch Door........................................................................................................51
Belt Switch (Switch Micro)....................................................................................52
Thermistor Fan......................................................................................................53
Motor Dryer......... ..................................................................................................54
Igniter As................................................................................................................55
Flame Sensor... ....................................................................................................57
Thermostat Hi-Limite.............................................................................................58
Thermostat Cut-Out...............................................................................................50
Valve Gas..............................................................................................50
Dismantling Method per Dryer Assy...................................................................51
What is a Dryer?
1. What is a Dryer?
A lifter, operated by a rotating drum, rolls laundry in the drum, and hot air heated by electricity (or gas) dries the
laundry through time or sensor dry system (a temperature control system) under various conditions.
2. Key Features
Large Capacity/Time-Saving
A large quantity of laundry can be dried at a time, saving energy as well as time.
Automatic Digital Dry
The digital sensor measures the humidity of laundry for optimum drying.
Large Door and Automatic Dry
The dryer has a large transparent door for convenient laundry dropping and checking.
Dust Filter
Fluff and dust are filtered during the drying process.
Sterilizing Dry
The high-temperature air dries laundry with sterilizing effects.
Drying Shoes
The dryer rack provided with the unit helps drying shoes as well as sensitive fabric.
Child Lock
This is the function that protects children from harm during the drying process.
3. Key Functions
Time Dry
Adjust the length of time for drying.
Sensor Dry
Automatically dry according to the types of laundry.
Custom Program
Remember most-frequently-used drying course.
Rack Dry
Dry sensitive fabric (e.g. sweaters, silk, lingerie) on the rack.
Wrinkle Care
Prevent wrinkles in case laundry stays in the drum after the drying process.
Antibacterial
Kill bacteria with high-temperature air.
Damp Dry Beep
Keep laundry damp enough to be ironed.
Dryer Specification
1. Product Look
u
5
y w
0
9
NO
FRAME DOOR O
PROTECTOR GLASS
PANEL FRONT
CABINET FRONT
PLATE TOP
7
8
i
3
q
e
1
6
Dimensions
Parts
CABINET
BUTTON POWER
BUTTON START
BADGE KLASSE
10
WINDOW COURSE
11
BUTTON FUNCTION
12
BUTTON OPTION
13
WINDOW DISPLAY
14
LESS TIME
15
MORE TIME
16
DECO COURSE
17
BUTTON DIAL
18
WINDOW FUNCTION
Weight
Capacity
Rated Power
Rating
Electric
Gas(LNG/LPG)
120/240V 60Hz
120V 60Hz
23.5A 5300W
5A 22.9lb
Electric Input
Operating Mechanism
Controller operation
Operator/gas burner/air supplier/ventilator operation
Automatic operation of the controller
Drying by the automatic sensor
lifter
plate top
control pannel
4. Heat Exchanger & Dryer
DRUM
LIFTER
Drying temperature sensor
Program
1. Controller
MAIN PCB
FRONT PCB
HARNESS
POWER CORD ASS'Y :15A
duct inlet
door
Laundry
cabinet front
filter as
3. Gas Burner
Gas Valve AS(LNG, LPG)
THERMOSTAT
duct outlet
impeller fan
5. FILTERING
FILTER ASS'Y
6. Air-Ventilator
Air-vent duct
2. Drive
IMPELLER FAN
MOTOR ASS'Y
THERMOSTAT
BELT/IDLER ASS'Y
TAPA SUPERIOR
PCB CONTROL
ENSAMBLE GABINETE
DRUM SUPORTE
POSTERIOR
PANEL F RONTAL
DUCTO DE
AIRE
SOPORTE TAMBOR
FRONTAL
CABINETE FRONTAL
QUEMADOR
ENSAMBLE TAMBOR
No.
C01-1
C01-2
C01-3
C02
C03
C04
C05
C06
C07
C08
C09
C10
-
Part Name
CABINET(ELECTRIC)
CABINET(GAS)
FRAME TOP L
FRAME TOP R
BASE UNDER
LOCK HARNESS M
FRAME UPPER
SCREW TAPPING
COVER BACK
SCREW TAPPING
COVER DUCT
FIXTURE PLATE
SCREW TAPPING
SUPPORTER LEG F
SUPPORTER LEG R
FIXTURE LEG
FOOT
SCREW TAPPING
C11
C01
SCREW TAPPING
C12
HARNESS AS
C13
C14
-
SCREW TAPPING
SPECIAL SCREW
COVER TERMINAL
SCREW TAPPING
PIPE EXHAUST AS
SCREW TAPPING
Part Code
Description
3610812350
SGCC 0.8T
3610812360
SGCC 0.8T
3612206500
SGCC 1.6T
3612206600
SGCC 1.6T
3610392900
SGCD 0.8T
3612207900
NYLON
3612207900
SGCC 1.2T
7121401411
T2S TRS 4x14
3611427900
SGCC 0.6T
7112401411
T1 TRS 4x14
3611428010
ABS
3612008000
POM
7121401211
T2S PAN 4x12
3615304200
SECC 3.0T
3615304300
SECC 3.0T
3612006400
ABS
3612100700
BUTYL
7122401411
T2S TRS 4x14
PRPSSWAD40
UL, Electric main
PRPSSWAD60
UL, Gas main
7122401411
T2S TRS 4x14
3612797000 UL, E-Dryer Main Harness
3612797300 CSA, G-Dryer Main Harness
7121401411
T2S TRS 4x14
7S422X4081 TT3 TRS 4x8 SE MFZN
3611428100
SGCC 1.0T
7112401411
T1 TRS 4x14
3614413600
SGCC 0.5T
7112401008
T1 TRS 4x14
Qtt'y
1
1
1
1
1
12
1
6
1
12
2
6
6
2
2
4
4
2
1
1
2
1
1
6
2
1
1
1
1
Remark
M03
M07
M04
M02
M06
M01
M09
M14
M05
M15
M12
M11
M08
M10
M13
M16
No.
Part Code
Description
Qtt'y
M01
BRACKET MOTOR
3610608500
SGCC 2.0T
M02
MOTOR DRYER
36189L5D00
AC 120V 60Hz
M03
CLAMP MOTOR
3611206000
SK5 0.7T
M04
BRACKET IDLER AS
3610609100
DWR-WE31
M05
SPRING IDLER
3615115500
HSW3
M06
SPECIAL BOLT
3616039000
S18A M6x10(FLANGE)
M07
Part Name
SWITCH MICRO
3619047500
SCREW TAPPING
7121301611
M08
CASE FAN F
3611144900
PP(Heat resisting)
M09
CASE FAN R
3611145000
PP(Heat resisting)
M10
GASKET PIPE
3612323200
EPDM(320*15*2.0t)
SCREW TAPPING
7112401411
T1 TRS 4x14
THERMOSTAT FAN
3619047900
UL.70ON.85OFF.125V/15A,250V/7.5A
M11
-
SCREW TAPPING
7121300811
M12
THERMISTOR FAN
361AAAAC10
UL-DRYER.R40=26.065K.R90=4.4278K
SCREW TAPPING
7122401411
T2 TRS 4x14
M13
IMPELLER FAN AS
3611886200
PP(Heat resisting)+BUSHING
M14
SPECIAL WASHER
3616039100
SPC
M15
SPECIAL NUT
3616039200
COVER FAN
3611428200
PP(Heat resisting)
SCREW TAPPING
7122401411
T2 TRS 4x14
M16
-
Remark
3. Gas Type
No.
G01
Part Name
VALVE AS
Part Code
Description
Qtt'y
DC12V,130mA 0.5Psi
LPG
3615417300
DC12V,130mA 0.5Psi
LNG
T1 M4*8
SGCC 1.0T
G02
SCREW TAPPING
G03
GUIDE BUNNER
3612511100
G04
MIXING VENTURI AS
3612209200
G05
SCREW TAPPING
G06
BRACKET IGNITER
G07
SCREW TAPPING
G08
SCREW TAPPING
G09
IGNITER AS
G10
O-RING
G11
PIPE AS
G12
SCREW TAPPING
G13
CAP PIPE
3610918200
PP
G14
FIXTURE FUNNEL
3612009200
SGCC 2.0T
G15
FUNNEL
3612511300
G16
SCREW TAPPING
G17
FLAME SENSOR AS
G18
SCREW TAPPING
G19
THERMOSTAT CUT-OUT
G20
SCREW TAPPING
G21
THERMOSTAT HI-LIMIT
G22
SCREW TAPPING
Remark
3615417200
M4*8, T1
SGCC 1.6T
T1 M48
T1 M48
3614604100
HNBR
3614413800
Pipe+Fixture+connector
WELDING
PS/W 412
3610609400
36189L5800
ALCOST 0.7T
T1 M4*8
3614825700
T1 M4*8
3619047810
T1 M4*8
3619047610
T1 M4*8
10
WELDING(SPOT)
4. INLETDUCT ASS'Y
A02
A01
A04
A05
A06
A03
No.
A01
Part Name
DUCT INLET REAR
A02
A03
A04
A05
A06
-
HEATER AS
THERMOSTAT HI-LIMIT
THERMOSTAT CUT-OUT
HARNES HEATER(DRYER)
SCREW TAPPING
SCREW TAPPING
Part Code
3617510200
3617510210
3617510300
3617510310
3612802500
3619047600
3619047800
3612797100
7122400811
7122400811
Description
ALCOSTAR 0.6t
ALCOSTAR 0.6t
ALCOSTAR 0.6t
ALCOSTAR 0.6t
240V 5,400W
125C OFF / 94C ON 250V 25A
140C OFF / -35C ON 250V 25A
UL1015 AWG12
T2S TRS 4x8 MFZN
T2S TRS 4x8 MFZN
11
Qtty
1
1
1
1
1
1
1
1
12
4
Remark
ELECTRIC TYPE
GAS TYPE
ELECTRIC TYPE
GAS TYPE
ELECTRIC TYPE
ELECTRIC TYPE
ELECTRIC TYPE
ELECTRIC TYPE
FOR FIXING DUCT INLET F & R
FOR FIXING SENSOR
B07
B02
B03
B01
B02
B04
B05
No.
Part Name
B01
B02
BRACKET SUP.R-SIDE
B03
BRACKET SUP.R-UPPER
3610608910
SGCC 1.0t
SCREW TAPPING
7122401411
B04
ROLLER AS
3614714400
ASSY
B05
WASHER SHAFT
3616039400
Part Code
Description
Qtt'y
3615304500
SUS304 0.8t
3610608810
SGCC 1.0t
B02
Remark
B06
NUT HEX
3616039300
M10 P1.5
B07
DUCT INLET AS
3617510110
ALCOSTA 0.6T
GAS TYPE
3617510100
ELECTRIC TYPE
12
No.
Part Name
Part Code
SECD 0.8T
Qtt'y
SUP. DRUM F
S02
HOUSING LAMP
3613053400
PP(Heat Resisting)
S03
SOCKET LAMP
3613053300
S04
LAMP
3613625300
AC 125V 15W
S05
WINDOW LAMP
3615505100
ABS(Transparent)
3615304600
Description
S01
Remark
SCREW TAPPING
7112401208
S06
ROLLER AS
3614714400
WE31'S Roller As
S07
WASHER SHAFT
3616039400
S08
NUT HEX
3616039300
M10 P1.5
S09
BODY FILTER R
3611909700
PP(Heat resisting)
S10
BODY FILTER F
3611909600
PP(Heat resisting)
S11
FILTER AS
3611909810
PP+NYLON MESH
S12
DUCT OUTLET AS
3617510400
DWR-WE31,ALCOSTA0.6t
SCREW TAPPING
7122401408
SCREW TAPPING
7122401408
Insert injection
S13
SENSOR MOISTURE
3614825500
STS430 2B 0.8T
S14
FIXTURE SENSOR A
3612009600
PP(Heat resisting)
S15
FIXTURE SENSOR B
3612009700
PP(Heat resisting)
S16
HARNESS SENSOR
3612797200
S17
LOCK HARNESS
3613802400
M TYPE 15x19
13
7. DRUM ASS'Y
D01
D03
D04
D02
D05
D04
D03
No.
Part Name
Part Code
Description
Qtt'y
D01
DRUM
3617010000
D02
LIFTER
361A401000
Heat resisting PP
SCREW TAPPING
7122502008
12
D03
SEAL DRUM AS
3614010600
D04
PAD DRUM
3614111110
BUTYL
D05
V-BELT
3616591200
14
Remark
8. DOOR ASS'Y
D09
D01
D05
D07
D02
D04
D03
D08
D06
No.
Part Name
Part Code
Description
Qtt'y
D01
FRAME DOOR I
3612208000
Heat resisting PP
D02
GLASS DOOR
36117ABR00
Glass or
D03
PROTECTOR GLASS
3618304300
Transparent ABS
D04
HINGE DOOR
3612903600
Zn-Dc Zn Plated
D05
3610916500
POM
D06
FRAME DOOR O
3612208110
ABS
D07
GASKET DOOR
3612323000
TPE
D08
COVER HANDLE
3611428310
ABS
D09
Remark
HOOK DOOR
3613101100
POM
SCREW TAPPING
7115401608
SCREW TAPPING
7115402008
15
16
9. PLATE T AS
No
Part Name
Part Code
Description
Qtt'y
T01
PLATE TOP
3614533010
SECD 1.2T
T02
PLATE SUPPORTER AS
3615304100
ABS + EPDM
SCREW TAPPING
7122401411
15
Remarks
G01
G03
G07
G05
G08
G04
G02
G09
G06
No.
Part Name
Part Code
Description
Qtt'y
G01
CABINET-F
3610812500
SGCD 0.8t
G02
GASKET CABINET F
3612323300
EPDM 460x15x4.0T
G03
SUPPORTER HINGE
3615304400
SGCC 2.0t
G04
DOOR LOCK AS
3613802500
2
1
SCREW TAPPING
7122401409
G05
SWITCH DOOR
3619047500
125V/5A
G06
DOOR AS
36117ABQ00
DWD-WE31
SCREW MACHINE
3616051229
G07
LABEL WARNING F
3613558800
PVC
G08
LABEL CAUTION F
3613557600
PVC
G09
LABEL RATING
3613558900
PVC
Remark
16
F14
F13
F17
F12
F16
F19
F15
F07
F06
F20
F18
F10
F05
F09
F11
F08
F01
F02
F04
F03
No.
F01
F02
F03
F04
F05
F06
F07
F08
F09
F10
F11
F12
F13
F14
F15
F16
F17
F18
F19
F20
Part Name
PANEL-F
BUTTON POWER
BUTTON START
SPRING BUTTON
DECO COURSE
WINDOW COURSE
WINDOW DISPLAY
BUTTON FUNCTION
WINDOW FUNCTION
BUTTON OPTION
SCREW TAPPING
BUTTON TIME
PCB -F AS
CUSTOM LED
CASE PCB-F
BUTTON DIAL AS
HOLDER COURSE
HOLDER LED
HOLDER OPTION
LABEL WIRING
CAP SCREW
Part Code
3614287000
3616635900
3616636000
3615115700
3611685400
3615504800
3615504900
3616636100
3615505000
3616636200
7122401411
3616636300
PRPSSWAD50
3613015500
3611145310
3616634700
3613053010
3613053110
3616053210
3613558100
3610917700
Description
ABS + SILK print
ABS
ABS
SUS304
ABS
Transparent ABS(TR558)
Transparent ABS(UT-0510)
ABS
ABS
Transparent ABS(TR558)
T2 TRS 4x14 MFZN
ABS
DWR-WE31
ABS
ABS(5VB, VE-0856))
DWD-130RP
ABS(5VB, VE-0856))
ABS(5VB, VE-0856))
ABS(5VB, VE-0856))
ABS
ABS
17
Qtt'y
1
1
1
2
1
1
1
1
1
1
7
1
1
1
1
1
1
1
1
1
1
Remark
18
Index
Features of the
dryer
Course and
Operation
Descriptions
1. Applied model: dryer for use in U.S.
2. Power source: ELECTRIC / LNG / LPG
3. Heating type: HEATER / GAS
4. Voltage: PCB & MOTOR 120V 60Hz / HEATER 240V 60Hz
5. PCB type: Front PCB (shared with other models)
Main PCB (3 types) : ELECTRIC, GAS ON/OFF CONTROL,
GAS PROPORTIONAL CONTROL
Adopted sensors
Load control
Display
Function options
Microcontroller
1. Humidity sensor
2. Temperature sensor: at the duct outlet
1. Motor
2. ELECTRIC HEATING : HEATER 2.5KW 2UNIT
3. GAS VALVE :
ON/OFF CONTROL / PROPORTIONAL CONTROL
19
Miscellaneous
2.Descripcin de cursos
2-1. Ciclos de secado
1) Cursos por Sensor
SECADO POR SENSOR
Very Dry
More Dry
NIVEL DE
Normal
SECADO
Less Dry
Damp Dry
Nivel por omisin
TEMP CONTROL
ANTI
Time
BACTERIAL
TEMP
Very Dry
More Dry
NIVEL DE
Normal
SECADO
Less Dry
Damp Dry
Nivel por omisin
Temp Control
ANTI
Time
BACTERIAL
TEMP
Normal
1:01
54
47
40
33
Normal
Medium
1:41
High
Cotton/Towels
1:05
1:02
59
56
53
Normal
Mid High
1:45
High
HEAVY DUTY
1:05
55
50
45
40
Normal
High
1:45
High
BULKY/LARGE
1:10
1:00
55
50
45
Normal
High
1:50
High
20
SPEED DRY
30
High
Ultra Low ~ High
FRESHEN UP
30
Mid high
Ultra Low ~ High
AIR DRY
35
-
WARM-UP
20
Medium
Ultra Low ~ High
21
2-2. Operation
1) Overview
Different operation processes are applied to Sensor Dry Course and Manual Dry Course.
Sensor Dry Course judges the condition of laundry with humidity/temperature sensors so as to decide
appropriate dry level.
Manual Dry Course dries laundry as per temperature conditions set by an operator.
22
23
24
Target Humidity
Damp Dry
80%~92%
Less Dry
88% ~ 96%
Normal
More Dry
Very Dry
25
4) Control de Temperatura
A. Presionando este boton la scuencia en display es la siguiente.
Medium - Mid High - High - Ultra Low - Low - Medium
B. Nivel seleccionado / temperatura de corte (termostato del ventilador)
Level
Target Temperatures
Heater-Off(C)
Heater-On(C)
High
63
56
Mid High
59
52
Medium
52
45
Low
48
41
Ultra Low
40
33
6) Beeper
A. If you press this button, the following is displayed in order.
'High - - Low - - Off'
B. Then, the volume of the beeper changes.
C. You can not change the beeper while the unit is in operation or stops temporarily.
7) More Time
A. Pressing this button increases time by a minute.
B. The time increases up to 1:55 (minutes)
C. You can change time in Manual Dry Course and Time Selection. Also Wrinkle Care can be
selected/cancelled.
26
8) Less Time
A. Pressing this button decreases time by a minute.
B. The time decreases up to 00:15 (minutes)
C. You can change time in Manual Dry Course and Time Selection. Also Wrinkle Care can be
selected/cancelled.
9) Custom Program
A. The function remembers most-frequently-used course and operation.
B. If you push this button after the power is switched on, Normal Course is displayed first and then the previously
programmed course.
C. How to start the operation
Press Custom Button --> Select course and operation --> Press Start Button on (If you press
Start Button, the course is programmed).
D. The same operation methods are applied to Custom Mode.
10) Rack Dry
A. If you press Rack Dry Button, time is set to 55 minutes without default temperature.
B. Only Low or Ultra Low is selected with the operation of Heater 1.
C. You can adjust time with More/Less Button.
D. Once Rack Dry is chosen, you can not select Wrinkle Care, Anti-Bacterial, Damp-Dry-Beep.
11) Anti-arrugas
A. Selecionando Anti-arrugas, no cambian los tiempos programados.
B. Para prevenir arrugas, el motor contina funcionando por 10 segundos y para 5 minutos y 50 segundos.
calentador se apaga, despus toda la operacin (incluyendo enfriamiento) finaliza.
C. El curso para solamente si se presiona pausa o se apaga la secadora.
D. Puede cancelar el curso durante la operacin o detener brevemente.
12) Anti-Bacterial
A. You can select this course only in Blanket, Heavy Duty, Cotton/Towels, or Normal Course.
B. If you press this button, 40 minutes of drying is added to a course regardless of humidity calculated by the
sensor.
C. Temperature is set to High and the dry level to Very Dry.
13) Damp Dry Beep
A. This button works only in Sensor Dry Course without changing time.
B. The unit beeps every 3 seconds after the target humidity is achieved until the operation is finished.
C. The beep stops if the door is opened or operation stops. When the operation is resumed, the beeper is off.
27
2-5. Option
Level
More Time
Less Time
Custom
Program
Rack Dry
Wrinkle
Anti
Damp Dry
Care
Bacterial
Beep
Bulky/Large
Heavy Duty
Cotton/Towls
Normal
Perm Press
Delicates
Ultra Delicates
Speed Dry
Freshen Up
Air Dry
Dry
A. If you select Rack Dry, the previous course and operation goes off.
B. If you select Rack Dry, Wrinkle Care, Anti-Bacterial, or Damp-Dry-Beep is not available.
28
29
Operacin Load
Time (Sec)
DISPLAY
Tipo
0.5
LEDs
0.5
1 : xx
0.5
2 : xx
Revisa SW de puerta
0.5
dc --> do
Revisa Motor
0.5
4 : nr
Revisa Ignitor
0.5
5 : U1
Secadora de gas
Revisa Vlvula 1
0.5
6 : U2
Secadora de gas
Revisa Vlvula 2
0.5
7 : U3
Secadora de gas
0.3
Fc --> Fo
Apagado
Total time
18 seconds
30
3
2
1
1
2
3
2
1
pink : MOTOR,
white :I GNITOR
purple:DOOR CHECK
DETECTOR DE FLAMA
brown blue
VALVULA control
black gray
blue
TRANS
FRONT PCB
SENSORES
31
Gua de fallas
ENCENDIDO / RUIDO
Problema
Sntoma
Cable de
Poder
Problema de partes
Elctricas de
secadora
Power
Problema
de Voltage
Problema PCB
Ruido al iniciar
Ruido durante
la operacin
Causa
Falla en cable de alimentacin
Fusible de servicio desconectado
Cable de poder daado
Terminal de controlador desconectada
Terminal desconectada del
block de conexiones
Fusible abierto
Rango para gas 120V
Rating for electric type: 120V/240V
Falla en la conexin
Falla de Circuito
Falla en S/W o Panel F
Error Microcomputador
Trajeta rota
Desconexin del arns
Instalacin
Objetos en el tambor
Objetos en el ventilador
Ruido
Operacin
Ventilador zafado
Carga excesiva
Objeto entre el tambor y el soporte
Friccin en la banda
32
Solucin
Revise suministro de
electricidad
Cambie el cable
Revise conexin
Conecte terminal
Cambie fusible
Revise voltaje
Check the rating
Compruebe la posicin
Cambie PCB
Cambie Panel F PCB
Cambie PCB
Cambie PCB
Revise conexin
Revise si la superficie
es plana
Retire objetos
Desensamble la unidad
y retire objetos
Asegure ventilador
Reduzca la carga
Retire objeto
Cambie banda
33
Dryer Installation
1. Installation Order
1 Place the dryer on the flat ground. Keep the unit at least 12 inch away from the wall.
2 Check the 4 legs and the gap between the unit and floor. The dryer should stand stably when
you try to move the unit to the left or right.
Balance the unit on the floor with the leg adjust as so that the inclination is not greater than 1 inch.
35
Service
Parts
Notices
Replacing the
Humidity sensor
humidity sensor
2
LIFTER
ROLLER
TERMINAL BLOCK
Drying heater
GAS BUNNER
Door assembly
Door hinge
Disassembly/assembly
Door as
of the door as
10
Disassembly/assembly
MOTOR AS
of the motor as
BELT
11
DRUM
36
Part Code
Lamp AS
3612625300
Type No
Rating
75W, 125V
15W, 125V
Main function
Power is applied to the lamp to turn up the
light in the drum when the door is opened.
Switch Door
3619047700
SPE110F-1D3
Thermistor Fan
361AAAAC20
CWT-DEW-1C18-A
5V R40=26.065K
R90=4.4278K
Switch Micro
3619047500
GSM-V1622A2
Motor Dryer
36189L5D00
S58NXSDD-6989
Igniter AS
36189L5800
DC033
Flame Sensor
3614825700
10RS 43828
Thermostat
3619047610
60T21
Hi-Limit
125V/25A 250V/25A
Thermostat
3619047810
PBR-380 N110
Cut-Out
125V/15A 250V/7.5A
Valve Gas AS
3615417200
"DEGB-1011, LPG"
Valve Gas AS
3615417300
"DEGB-1011, LNG"
* Parts surrounded by dotted line are exclusively for gas dryer. Other parts are common parts for electric/ gas dryer.
37
Termostato Ventilador
Part Code : 3619047900
1. Function
This is a bimetal-type switch which protects the clothes from damage by
overheating.
If the exaust air is too hot, this thermostat stops the motor and after the air is
cooled down, it restarts the motor.
2. Especificacin
Es un termostato bimetico normalmente cerrado
Rango elctrico : 15A at 125V
Temperatura de corte: 855C, Temperatura de cierre: 705C
Type name : PW-3N
3. Checking method of mal-function
If temperatures are normal, the terminals of this part are connected to each other.
Put the round metal part into boiling water and check if the resistance between the terminals drops to
0.3 or below.
Put the same part into cold water and check if the terminals are opened.
If the terminals do not react as mentioned above, replace them.
4. Procedure of replacement
1 Plate Top remove
2 Panel F Ass'y remove
3 Cabinet Front Ass'y remove
4 Frame Upper remove
5 Drum Ass'y remove
Thermostat Fan
6 check the position of the part
7 Remove the wires and screws to disassemble the part.
8 Assemble the parts in reverse order.
38
Lmpara
Part Code : 3612625300
1. Function
This is a lamp assembled with its bracket and window.
If the user opens the door, the door switch gives electric power to this
lamp and it turns on.
2. Especificacin
An assembly of an electric lamp, bracket and window.
Consumo : 15W at 120V
Type name : TGE-12015L
Lamp Ass'y
39
Switch de Puerta
Part Code : 3619047700
1. Function
This is a switch that checks whether the door is open or closed.
If the user opens the door, this switch disconnects power supply to the
motor and turns the lamp on.
If the user closes the door, this switch connects power supply to the
motor and turns the lamp off.
2. Especificacin
Push switch - con 3 terminales
oprimido : Conecta a motor
libre : Conecta a lmpara
Rango elctrico: 7.5A 125V
Type name : SPE110F
Door Switch
4 Remove the wires. Press both ends of the switch and pull.
5 Assemble the parts in reverse order.
40
Switch de Banda
Part Code : 3619047500
1. Function
The switch cuts the power supply to the motor when a belt is
broken.
The switch is on when the belt has adequate tension but off when
the belt gets loosened or broken, blocking the power supply to the
motor.
2. Especificacin
Micro switch con 2 terminales, NC (normalmente cerrado)
libre : COM y NO son conectados
activado : COM y NC son desconectados
Rango elctrico : 250V 16A 1/2HP
Type name : GSM-V1622A2
3. Checking method of mal-function
The switch is in normal operation if the drum rotates.
Start the unit and check if the drum operates.
If the drum fails to rotate, press the power button to stop the dryer and then again to check if the motor
runs.
If you can not hear the running of the motor, disassemble the dryer and check the belt switch contact.
Press the lid of the belt switch. If the resistance between contacts is greater than 1, replace the belt.
4. Procedure of replacement
1 Plate Top remove
2 Panel F Ass'y remove
3 Cabinet Front Ass'y remove
4 Frame Upper remove
5 Drum Ass'y remove
6 Check the position of the part.
41
Belt Switch
42
Thermistor Ventilador
Part Code : 361AAAAC20
1. Function
The fan senses the temperature of exhaust air.
The higher the temperature is, the smaller the resistance is.
2. Especificacin
Caractersticas temperatura-resistencia del Thermistor.
a 90C : R = 4.43 k
a 40C : R = 26.07 k
Type name : CWT-DWE-1C18-A
3. Checking method of mal-function
If the resistance between terminals is within the adequate range, the fan is in
normal operation.
You can test the resistance of the thermistor as follows.
- Put the metal rod into cold water (10~20C): 40 within 30 seconds
- Put the metal rod into boiling water (95~100C): 4 within 30 seconds
If H2 error is displayed when you press the power and start button, the thermistor is not connected so
replace it.
4. Procedure of replacement
1 Plate Top remove
2 Panel F Ass'y remove
3 Cabinet Front Ass'y remove
4 Frame Upper remove
5 Drum Ass'y remove
6 Check the position of the part.
Thermistor Fan
43
Motor Dryer
Part Code : 36189L5D00
1. Function
The motor rotates the drum using the belt as well as the fan to expel wet air.
This is a shunt AC motor. When the motor begins to run, a centrifugal switch shorts out the operation
coil.
The centrifugal switch also supplies power to the heater. Thus, if the motor stops, the heater goes off
also.
Belt assembly
Inner wiring
2. Specification
Motor de 1/3 HP AC con switch centrifugo
Velocidad: 1600 rpm con carga
Sin carga: 190W, 4.9A at 120V
Con carga: 555W, 6.1A at 120V
Type name : S58NXSDD-6989
3. Checking method of mal-function
If the drum rotates and exhaust air is expelled as soon as you start the unit, the motor is in normal
operation.
If the drum fails to rotate;
1 Remove Plate T and check if the belt is damaged.
2 Check if the door switch is in normal operation.
3 Remove the drum and check the thermostat fan.
4 Check the belt switch.
5 Run the unit while you press the lid of the belt switch and see if the motor starts operating.
If a fault is found in any part mentioned above, replace it and check the operation of the motor (5).
If no fault is found but the motor still fails to operate5, replace the motor.
4. Procedure of replacement
1 Plate Top Remove
2 Panel F Ass'y Remove
3 Cabinet Front Ass'y Remove
4 Frame Upper Remove
5 Drum Ass'y Remove
6 Cover Fan Remove
44
9 Remove wires and 2 clamps that fix the motor bearing to detach the motor.
0 Assemble the parts in reverse order.
45
Ignitor
Part Code : 36189L5800
1. Function
Igniter for fuel gas ignition.
Igniter heats up quickly when power is supplied. If fuel gas is
injected to the surrounding area of igniter, gas is ignited by
the heat of igniter.
2. Specification
A heating element made by Silicon Carbide
Rango elctrico : 120V 4.0A
Rango de temperatura : 982 C en 30 seg.
Type name : DC033
3. Checking method of mal-function
Igniter is heated up to very high temperature. Therefore, extreme caution is required in handling to
prevent burn.
At room temperature, resistance between two terminals of this part is generally between 300~400
Part is defective if resistance between terminals measured after separating cable connected to igniter is
250 or less.
Part is defective if cracks are found when separating igniter and closely observing the surface.
In two of the above conditions, igniter is defective, therefore needs to be replaced.
Laniter As
4. Procedure of replacement
1 Plate Top Remove
2 Panel F Ass'y Remove
3 Cabinet Front Ass'y Remove
4 Frame Upper Remove
5 Drum Ass'y Remove
6 Cover Fan Remove
7 Separate the connected cable and unfasten 1 screw
to separate parts.
8 Assemble part in reverse order of the above
procedures.
46
Sensor de Flama
Part Code : 3614825700
1. Function
Sensor flame is the switch that operates by detecting fuel gas
ignition or heating of igniter.
Contact point is opened when sufficient radiant heat is detected
through the transparent window at the bottom of sensor.
When igniter is sufficiently heated, this is detected to turn off igniter.
Then, state of internal contact point is continuously maintained to
be off by combustion heat of the ignited gas.
When gas supply is cut off, state of internal contact point becomes 'on' again so that to enable re-ignition
by igniter.
2. Especificacin
Switch bi-metal que opera por radiacin de calor
Rango elctrico : 120V 5.75A
Operacin : abre entre 12~20 seg. despus de que la radiacin de calor comienza.
cierra entre 26~30 seg. despus de que la radiacin termina.
Type name : 10RS
3. Checking method of mal-function
At room temperature, there is the state of short between two terminals of this part.
Part is defective if resistance between terminals measured after separating cables
connected to sensor flame is 1 or more.
Part is defective if the area between terminals is not opened 30 seconds after
separating sensor flame and holding flame of lighter near transparent window at the bottom
(less than 1cm).
- Flame of lighter must be as long as the length of transparent window and
the flame must not be in direct contact with transparent window.
- Transparent window of sensor flame must be kept clean at all times to
enable normal operation.
Part is detective if resistance between terminals is not 0.3 or less within 50
seconds after removing the flame of lighter.
In three of the above conditions, sensor flame is detective, therefore needs to be replaced.
4. Procedure of replacement
1 Remove plate top.
Sensor Flame
2 Remove panel F ass'y.
3 Remove cabinet front ass'y.
4 Remove frame upper.
5 Remove drum ass'y.
6 Check attachment position.
7 Separate the connected cable and unfasten 1 screw to
separate parts.
8 Assemble part in reverse order of the above procedures.
47
Laniter As
Thermostat-Limit
48
Termostato de Corte
Part Code : 3619047810
1. Function
This is a bimetal-type switch which protects the burner from overheating.
If the burner is overheated abnormally, this thermostat cuts off the gas
valves PERMANENTLY.
Note that this thermostat is MANUALLY-RESETTABLE; by pressing the
knob on the top, this part is returned to reusable state.
2. Especificacin
Termostato bi-metalico normalmente cerrado.
Rango elctrico : 15A a 125V
Abre a : 110+ - 5C, Cierra a : 35C
Type name : PBR-380
3. Checking method of mal-function
In normal operation status, the area between terminals must not be opened.
If it is opened (resistance between terminals 100M or more), press knob at the top two or three
times to restore.
If resistance between terminals is 1 or more after manual restoration, replace part as it is defective.
(This part is restored to be reused if placed at temperature of -35C or lower. However, this is an
extremely low temperature that cannot be reached with general refrigerator for household use.
Therefore, it is effective to press knob for restoration.)
4. Procedure of replacement
1 Remove plate top.
2 Remove panel F ass'y.
3 Remove cabinet front ass'y.
4 Remove frame upper.
5 Remove drum ass'y.
6 Remove mixing venturi AS.
6Mixing Venturi AS
7Funnel
8Thermostat Cut-Out
7 Unfasten 2 screws fixing funnel in position and separate all of the connected cables. Then, carefully
take out funnel.
8 Remove 2 screws and separate thermostat cut-out.
9 Assemble part in reverse order of the above procedures.
49
Vlvula de Gas
Part Code : 3615417200, -7300
1. Function
Valve gas AS supplies or blocks off fuel gas.
2 valves are horizontally connected to safely block off gas leakage.
Each valve is solenoid value. Gas passed through this valve is injected after
being stabilized to the prescribed output pressure in regulator.
Therefore, even if input pressure of supplied gas changes, the prescribed
amount of gas is stably supplied.
2. Specification
Part Code
LPG
LNG
Type Name
Electric Rating
DEGB-1011
3615417200
3615417300
2.24 kPa
1.0~3.5 kPa
0.87 kPa
6Pipe AS
7Guide Buner
50
MTODO DE DESENSAMBLE
PANEL FRONTAL
1. Quite el tapn izquierdo y retire el tornillo.
TAPA SUPERIOR
1. Retire 3 tornillos del frente.
51
GABINETE FRONTAL
1. Retire 4 tornillos superiores.
2. Saque el filtro.
3. Retire 3 tornillos.
52
MARCO SUPERIOR
1. Retire 1 tornillo de cada lado del marco.
53
PCB MAIN
1. Retire 2 tornillos.
DUCTO DE SALIDA
1. Retire 2 tornillos de cada lado.
54
TAPA POSTERIOR
1. Retire 10 tornillos.
2. Retire 7 tornillos.
55
CABLEADO Y MOTOR
1. Separacin del sensor de temperatura : Desconecte.
Retire el tornillo.
Retire 2 tornillos.
56
BLOCK DE TERMINALES
1. Remove cover terminal.
2. Remove 3 screws.
57
ENSAMBLE MOTOR
1. Retire 6 tronillos y separe el motor.
58
LMPARA
1. Retire 1 tornillo.
59
3. Remueva Sensor.
60
PUERTA
1. Separacin de bisagra y soporte tambor frontal: Retire 2 tornillos.
2. Retire 13 tornillos
61