You are on page 1of 42

ETERNUS

ETERNUS DX 60 S2, DX80 S2, DX90 S2 Disk Storage Systems


System Configuration Guide February 2013, 6th edition
CONTENTS
[Specification]
(1) ETERNUS DX60 S2
(2) ETERNUS DX80 S2
(3) ETERNUS DX90 S2
(4) Supported RAID

1
2
3
4

[Outline]
(1) View
(2) Product Diagrams

5
7

[System configuration tree diagram]


(1) ETERNUS DX60 S2 (Dual-controller type)
(2) ETERNUS DX60 S2 (Single-controller type)
(3) ETERNUS DX80 S2 (Dual-controller type)
(4) ETERNUS DX80 S2 (Single-controller type)
(5) ETERNUS DX90 S2 (Dual-controller type)
(6) ETERNUS DX90 S2 (Single-controller type)
(7) Options
(8) Cables
(9) Rack
(10) ETERNUS Multipath Driver

9
11
14
17
20
23
26
39
40
41

Product ID/Descriptions
Each product has "Product Description", "ProductID"
and "Brief Remarks" as follows.

Drive enclosure
- Rackmount type 2U
ETLDE2AU
Product ID

Brief Remarks

Concurrent
connections
permitted

Product name
Select only

Ex)

Meaning of each circle ()


=> Only one selection can be made
=>Multiple selections are possible.
(There may be some restriction)

Copyright 2013 FUJITSU LIMITED

ETERNUS DX60 S2, DX80 S2, DX90 S2


(1) ETERNUS DX60 S2 Specification
Product name

ETERNUS DX60 S2
2.5" MODEL

3.5" MODEL
DUAL
SINGLE
DUAL
CONTROLLER
CONTROLLER
CONTROLLER
0, 1, 1+0, 5, 5+0, 6
Max. 24.0TB
Max. 72.0TB
Max. 17.8TB
Max. 53.4TB
1
2
1
2
Fibre Channel (Max. 4Gbit/s)
iSCSI (Max. 1Gbit/s)
SAS (Max. 3Gbit/s)
2
4
2
4
32, 64 (2, 4 for SAS connection)
1GB
2GB
1GB
2GB
2 - 24
600GB, 450GB, 300GB (15,000rpm)
SAS (Max. 3Gbit/s)
3TB, 2TB, 1TB (7,200rpm)
SAS (Max. 3Gbit/s)
900GB, 600GB,450GB,300GB(10,000rpm)
SAS (Max. 3Gbit/s)
1TB (7,200rpm)
SAS (Max. 3Gbit/s)
483 650 88 mm (2U)
483 650 88 mm (2U)
483 650 88 mm (2U)
35 kg
35 kg
35 kg
AC 100 - 120 V / AC 200 - 240 V
Single
50 Hz / 60 Hz
510W (520VA) [1,840kJ/h]
440W (450VA) [1,590kJ/h]
370W (380VA) [1,340kJ/h]
500W (510VA) [1,800kJ/h]
430W (440VA) [1,550kJ/h]
370W (380VA) [1,340kJ/h]
10 - 40 C (Operating), 0 - 50 C (Non-operating)
20 - 80 %RH (Operating), 8 - 80 %RH (Non-operating)
SINGLE
CONTROLLER

Supported RAID levels


Storage Capacity *1

Physical capacity *2
Logical capacity *3

Number of controllers
Host Interfaces

Number of host interfaces


Number of connectable hosts
Cache memory capacity
Number of drives
3.5"
Capacity (rotation speed)
SAS disk drive
Drive interface
3.5" nearline
Capacity (rotation speed)
SAS disk drive
Drive interface
Capacity
3.5" SSD
Drive interface
Disk Drives
2.5"
Capacity (rotation speed)
SAS disk drive
Drive interface
2.5" nearline
Capacity (rotation speed)
SAS disk drive
Drive interface
Capacity
2.5" SSD
Drive interface
Controller Enclosure
Dimensions (W x D x H)
Drive Enclosure
Maximum Weight
Controller Enclosure
(per one Enclosure)
Drive Enclosure
Voltage
Power
Phase
Frequency
Controller Enclosure
Maximum Power
AC100-120V
Consumption
Drive Enclosure
[Maximum Heat
Controller Enclosure
AC200-240V
Generation]
Drive Enclosure
Temperature
Environmental Conditions
Humidity
*1: Storage capacity depends on which HDDs are mounted.
*2: The physical capacity value was calculated as 1 KByte = 1,000 Bytes.
*3: The logical capacity value was calculated as 1 KByte = 1,024 Bytes when formatted as RAID5.
User area capacity differs depending on the environment.

ETERNUS DX60 S2, DX80 S2, DX90 S2


(2) ETERNUS DX80 S2 Specification
Product name

ETERNUS DX80 S2
2.5" MODEL *1
3.5" MODEL
SINGLE
DUAL
SINGLE
DUAL
CONTROLLER
CONTROLLER
CONTROLLER
CONTROLLER
Supported RAID levels
0, 1, 1+0, 5, 5+0, 6
Max. 360.0TB
Physical capacity *3
Storage Capacity *2
Max. 267.0TB
Logical capacity *4
Number of controllers
1
2
1
2
Fibre Channel (Max. 16Gbit/s)
iSCSI (Max. 1Gbit/s)
Host Interfaces
iSCSI (Max. 10Gbit/s)
SAS (Max. 6Gbit/s)
FCoE (Max. 10Gbit/s)
Number of host interfaces
2/4
4/8
2/4
4/8
Number of connectable hosts
Max. 1,024
Cache memory capacity
2GB
4GB
2GB
4GB
Number of drives
2-120
600GB, 450GB, 300GB (15,000rpm)
3.5"
Capacity (rotation speed)
SAS disk drive
SAS (Max. 6Gbit/s)
Drive interface
3TB, 2TB, 1TB (7,200rpm)
3.5" nearline
Capacity (rotation speed)
SAS disk drive
SAS (Max. 6Gbit/s)
Drive interface
800GB, 400GB, 200GB, 100GB
Capacity
3.5" SSD
SAS (Max. 6Gbit/s)
Drive interface
Disk Drives
900GB, 600GB,450GB,300GB(10,000rpm)
2.5"
Capacity (rotation speed)
SAS (Max. 6Gbit/s)
SAS disk drive
Drive interface
1TB (7,200rpm)
2.5" nearline
Capacity (rotation speed)
SAS disk drive
SAS (Max. 6Gbit/s)
Drive interface
800GB, 400GB, 200GB, 100GB
Capacity
2.5" SSD
SAS (Max. 6Gbit/s)
Drive interface
482 645 88 mm (2U)
482 670 88 mm (2U)
Controller Enclosure
Dimensions (W x D x H)
482 540 88 mm (2U)
482 555 88 mm (2U)
Drive Enclosure
35 kg
35 kg
Maximum Weight
Controller Enclosure
(per one Enclosure)
35 kg
35 kg
Drive Enclosure
AC 100 - 120 V / AC 200 - 240 V
Voltage
Power
Single
Phase
50 Hz / 60 Hz
Frequency
630W (640VA) [2,300kJ/h]
620W (630VA) [2,300kJ/h]
Controller Enclosure
Maximum
AC100 - 120V Drive Enclosure
570W (580VA) [2,100kJ/h]
550W (560VA) [2,000kJ/h]
Power
5,570W (5,670VA) [20,300kJ/h]
Consumption
Maximum configuration
[Maximum
630W (640VA) [2,300kJ/h]
610W (620VA) [2,200kJ/h]
Controller Enclosure
Heat
AC200 - 240V Drive Enclosure
570W (580VA) [2,100kJ/h]
550W (560VA) [2,000kJ/h]
Generation]
5,560W (5,660VA) [20,200kJ/h]
Maximum configuration
10 40 C (Operating), 0 - 50 C (Non-operating)
Temperature
Environmental Conditions
20 - 80 %RH (Operating), 8 - 80 %RH (Non-operating)
Humidity
*1: 2.5" base unit items are based on configuration with 2.5" drive enclosures only.
*2: Storage capacity depends on which HDDs are mounted.
*3: The physical capacity value was calculated as 1 KByte = 1,000 Bytes.
*4: The logical capacity value was calculated as 1 KByte = 1,024 Bytes when formatted as RAID5.
User area capacity differs depending on the environment.
*5: Mixtures of 2.5" and 3.5" drives are supported by adding both 2.5" and 3.5" drive enclosures.

ETERNUS DX60 S2, DX80 S2, DX90 S2


(3) ETERNUS DX90 S2 Specification
Product name

ETERNUS DX90 S2
2.5" MODEL *1
3.5" MODEL
SINGLE
DUAL
SINGLE
DUAL
CONTROLLER
CONTROLLER
CONTROLLER
CONTROLLER
Supported RAID levels
0, 1, 1+0, 5, 5+0, 6
Max. 360.0TB
Physical capacity *3
Storage Capacity *2
Max. 267.0TB
Logical capacity *4
Number of controllers
1
2
1
2
Fibre Channel (Max. 16Gbit/s)
iSCSI (Max. 1Gbit/s)
Host Interfaces
iSCSI (Max. 10Gbit/s)
SAS (Max. 6Gbit/s)
FCoE (Max. 10Gbit/s)
Number of host interfaces
2/4
4/8
2/4
4/8
Number of connectable hosts
Max. 1,024
Cache memory capacity
4GB
8GB
4GB
8GB
Number of drives
2-240
2-120
600GB, 450GB, 300GB (15,000rpm)
3.5"
Capacity (rotation speed)
SAS disk drive
SAS (Max. 6Gbit/s)
Drive interface
3TB, 2TB, 1TB (7,200rpm)
3.5" nearline
Capacity (rotation speed)
SAS disk drive
SAS (Max. 6Gbit/s)
Drive interface
800GB, 400GB, 200GB, 100GB
Capacity
3.5" SSD
SAS (Max. 6Gbit/s)
Drive interface
Disk Drives
900GB, 600GB,450GB,300GB(10,000rpm)
2.5"
Capacity (rotation speed)
SAS (Max. 6Gbit/s)
SAS disk drive
Drive interface
1TB (7,200rpm)
2.5" nearline
Capacity (rotation speed)
SAS disk drive
SAS (Max. 6Gbit/s)
Drive interface
800GB, 400GB, 200GB, 100GB
Capacity
2.5" SSD
SAS (Max. 6Gbit/s)
Drive interface
482 645 88 mm(2U)
482 670 88 mm(2U)
Controller Enclosure
Dimensions (W x D x H)
482 540 88 mm(2U)
482 555 88 mm(2U)
Drive Enclosure
35 kg
35 kg
Maximum Weight
Controller Enclosure
(per one Enclosure)
35 kg
35 kg
Drive Enclosure
AC 100 - 120 V / AC 200 - 240 V
Voltage
Power
Single
Phase
50 Hz / 60 Hz
Frequency
630W (640VA) [2,300kJ/h]
620W (630VA) [2,300kJ/h]
Controller Enclosure
Maximum
AC100 - 120V Drive Enclosure
570W (580VA) [2,100kJ/h]
550W (560VA) [2,000kJ/h]
Power
5,760W (5,860VA) [21,200kJ/h]
Consumption
Maximum configuration
[Maximum
630W (640VA) [2,300kJ/h]
610W (620VA) [2,200kJ/h]
Controller Enclosure
Heat
AC200 - 240V Drive Enclosure
570W (580VA) [2,100kJ/h]
550W (560VA) [2,000kJ/h]
Generation]
5,760W (5,860VA) [21,200kJ/h]
Maximum configuration
10 - 40 C (Operating), 0 - 50 C (Non-operating)
Temperature
Environmental Conditions
20 - 80 %RH (Operating), 8 - 80 %RH (Non-operating)
Humidity
*1: 2.5" base unit items are based on configuration with 2.5" drive enclosures only.
*2: Storage capacity depends on which HDDs are mounted.
*3: The physical capacity value was calculated as 1 KByte = 1,000 Bytes.
*4: The logical capacity value was calculated as 1 KByte = 1,024 Bytes when formatted as RAID5.
User area capacity differs depending on the environment.
*5: Mixtures of 2.5" and 3.5" drives are supported by adding both 2.5" and 3.5" drive enclosures.

ETERNUS DX60 S2, DX80 S2, DX90 S2


(4) Supported RAID
The ETERNUS DX60 S2/DX80 S2/DX90 S2 support the following RAID levels.
Use of RAID0 is not recommended because it is not redundant.
For RAID0 configurations, data may be lost due to disk drive failure.

RAID level
RAID0
RAID1
RAID1+0

RAID5

RAID5+0

RAID6

Supported number disk drives


ETERNUS DX80 S2
ETERNUS DX60 S2
ETERNUS DX90 S2
2 - 16
2 - 16
2
2
4 - 24
4 - 32

3 - 16

3 - 16

(3 - 12) x 2

(3 - 16) x 2

5 - 16

5 - 16

Recommended number disk drives

*1: Use of RAID0 is not recommended because it is not redundant.

*1
2 (1Data + 1Mirror)
4 (2Data + 2Mirror)
6 (3Data + 3Mirror)
8 (4Data + 4Mirror)
10 (5Data + 5Mirror)
3 (2Data + 1Parity)
4 (3Data + 1Parity)
5 (4Data + 1Parity)
6 (5Data + 1Parity)
3 (2Data + 1Parity) x 2
4 (3Data + 1Parity) x 2
5 (4Data + 1Parity) x 2
6 (5Data + 1Parity) x 2
5 (3Data + 2Parity)
6 (4Data + 2Parity)
7 (5Data + 2Parity)

ETERNUS DX60 S2, DX80 S2, DX90 S2


ETERNUS DX60 S2 View
(1) ETERNUS DX60 S2 View
- Base unit

Front Cover

Base unit front view

Base unit front view

(3.5" type)

(2.5" type)

Controller (Standard)
(Additional Controller (Option))
Host Interface (Standard)

AC power cable (200V)(Standard)

LAN port
Drive interface (OUT) port
Power Supply Unit (Standard)

Base unit rear view

- Drive Enclosure

Front Cover

Drive Enclosure front view


(3.5" type)

Drive interface (OUT) port


Drive interface (IN) port
AC power cable (200V)(Standard)

Power Supply Unit (Standard)

Drive Enclosure rear view

ETERNUS DX60 S2, DX80 S2, DX90 S2


ETERNUS DX80 S2, DX90 S2 View
(2) ETERNUS DX80 S2, DX90 S2 View
- Base unit (Controller Enclosure)

3.5" disk

2.5" disk

Base unit front view

Base unit front view

(3.5" type)

(2.5" type)

Controller (Standard)
(Additional Controller (Option))
Host Interface (Standard)

AC power cable (200V)(Standard)

LAN port
Drive interface (OUT) port
Power Supply Unit (Standard)

Base unit rear view

- Drive Enclosure

3.5" disk

2.5" disk

Drive Enclosure front view

Drive Enclosure front view

(3.5" type)

(2.5" type)

Drive interface (OUT) port


Drive interface (IN) port
AC power cable (200V)(Standard)

Power Supply Unit (Standard)

Drive Enclosure rear view

ETERNUS DX60 S2, DX80 S2, DX90 S2


ETERNUS DX60 S2 Product Diagrams
Server
LAN cable (category 5e) 5m x 2
(Setup node/Management LAN
Connection)(Option)

HBA (Host Bus Adaptor):


FC / SAS / LAN card

Host Interface cable (Option)


FC cable (5m) x 2
LAN cable (category 5e)(5m) x2
SAS cable (1.5m) x2
ETERNUS DX60 S2 base unit
Controller Enclosure
(Standard)

Host interface
(Standard)

Controller Enclosure
(Standard/Option)

Host interface
(Standard/Option)
AC power cable 200V 4m x2

Disk Drive (Option) (Max, 12/24 drives can be installed *1)

......

Power distribution unit (AC200V) (Option)

SAS cable (0.75m) x2


(Attached to Drive Enclosure)
Extension cable (Option)
SAS cable (3m or 6m) x2
(Order when standard cable is too short)
3.5" Drive Enclosure (Option) *2
AC power cable 200V 4m x2

Disk Drive (Option) (Max, 12 drives can be installed)

......

Power distribution unit (AC200V)


(Option) (Share with base unit)

*1: Up to twelve 3.5" disk drives or twenty-four 2.5" disk drives can be installed in each controller enclosure.
(Mixture of 2.5/3.5inch drives in the same enclosure is not supported.)
*2: The following table shows the type and number of drive enclosures that can be installed in DX60 S2.
Drive Enclosure
Base unit
3.5" type
2.5" type
Max. 1
Not supported
3.5" type
ETERNUS DX60 S2
Not supported
Not supported
2.5" type

ETERNUS DX60 S2, DX80 S2, DX90 S2


ETERNUS DX80 S2, DX90 S2 Product Diagrams
Server
LAN cable (category 5e) 5m x 2
(Setup node/Management LAN
Connection)(Option)

HBA (Host Bus Adaptor):


FC / SAS / LAN / FCoE card

(Remote monitoring function requires additional LAN

Host Interface Option


(At least one set of Host interfaces is mandatory for
single-controller model. And two of the same host
interface sets are mandatory for dual-controller.)
- Fibre Channel
- SAS
- iSCSI (1Gbit/s)
- iSCSI (10Gbit/s)
- FCoE
ETERNUS DX80 S2, DX90 S2 base unit
Controller Enclosure
(One option must be chosen)

Controller Enclosure
(One option must be
chosen)

AC power cable 200V 4m x2


IEC cable x2 (Option)

Disk Drive (Option) (Max, 12/24 drives can be installed *1)


Power distribution unit (AC200V)

......

(Option)

Thin Provisioning Feature (Option)


(Max. one license can be installed)

SAS cable (0.75m) x2


(Attached to Drive Enclosure)
Extension cable (Option)
SAS cable (3m or 6m) x2
(Order when standard cable is too short)
Drive Enclosure (Option)
Total four/nine DE (2.5"/3.5") can be installed. *2
Disk Drive (Option) (Max, 12/24 drives can be installed *1)

......

AC power cable 200V 4m x2


IEC cable x2 (Option)

Power distribution unit (AC200V)


(Option) (Share with base unit)

*1: Up to twelve 3.5" disk drives or twenty-four 2.5" disk drives can be installed in each controller enclosure.
(Mixture of 2.5/3.5inch drives in the same enclosure is not supported.)
*2: Mixture of 3.5" type drive enclosures and 2.5" type drive enclosures enables
mixture of 3.5" drives and 2.5" drives in the same machine.
Up to 120 drives can be installed in a single ETERNUS DX80 S2.
Up to 240 drives can be installed in a single ETERNUS DX90 S2.
The following table shows the type and number of drive enclosures that can be installed in DX80 S2/DX90 S2.
Drive Enclosure
Base unit
3.5" type
2.5" type
Max. 9
Max. 4
3.5" type
ETERNUS DX80 S2
Max. 9
Max. 4
2.5" type
Max. 9
Max. 9
3.5" type
ETERNUS DX90 S2
Max. 9
Max. 9
2.5" type
8

ETERNUS DX60 S2, DX80 S2, DX90 S2


(1) ETERNUS DX60 S2 (dual-controller type)

i) ETERNUS DX60 S2 base unit (Dual controller type, Fibre Channel connection)
Product name
Product ID

Configuration

Notes

ETERNUS DX60 S2
ETERNUS DX60 S2
(2.5inch, 4Gbps, FC, dual-controller) (3.5inch, 4Gbps, FC, dual-controller)
ET062DCFU
ET062DDFU
Rackmount type (2U), AC200V model
Enclosure x1
- Controller (FC4Gbit/s x 2ports) x2
- Cache memory (1G) x2
- Power Supply Unit x2
At least two disk drives are mandatory. Up to 24 drives can be added.
Up to 24 drives can be installed in 2.5" type base unit.
Up to 12 drives can be installed in 3.5" type base unit and drive enclosure.
2.5" Drive Enclosure cannot be added.
One 3.5" Drive Enclosures can be added.

- Contents of Package
Components
AC200V power cord
Rack mount kit
Safety Precautions
User Guide
Read me first

Quantity
2
1 set
1
1
1

Note
4m (NEMA L6-15P)

CD

ii) ETERNUS DX60 S2 base unit (Dual controller type, SAS connection)
Product name
Product ID

Configuration

Notes

ETERNUS DX60 S2
ETERNUS DX60 S2
(2.5inch, 3Gbps, SAS, dual-controller) (3.5inch, 3Gbps, SAS, dual-controller)
ET062DCSU
ET062DDSU
Rackmount type (2U), AC200V model
Enclosure x1
- Controller (SAS x 2ports) x2
- Cache memory (1G) x2
- Power Supply Unit x2
At least two disk drives are mandatory. Up to 24 drives can be added.
Up to 24 drives can be installed in 2.5" type base unit.
Up to 12 drives can be installed in 3.5" type base unit and drive enclosure.
2.5" Drive Enclosure cannot be added.
One 3.5" Drive Enclosures can be added.

- Contents of Package
Components
AC200V power cord
Rack mount kit
Safety Precautions
User Guide
Read me first

Quantity
2
1 set
1
1
1

Note
4m (NEMA L6-15P)

CD

ETERNUS DX60 S2, DX80 S2, DX90 S2


(1) ETERNUS DX60 S2 (dual-controller type)

iii) ETERNUS DX60 S2 Base Unit (Dual controller type, iSCSI connection)
Product name
Product ID

Configuration

Notes

ETERNUS DX60 S2
ETERNUS DX60 S2
(2.5inch, 1Gbps, iSCSI, dual(3.5inch, 1Gbps, iSCSI, dualET062DCLU
ET062DDLU
Rackmount type (2U), AC200V model
Enclosure x1
- Controller (iSCSI x 2ports) x2
- Cache memory (1G) x2
- Power Supply Unit x2
At least two disk drives are mandatory. Up to 24 drives can be added.
Up to 24 drives can be installed in 2.5" type base unit.
Up to 12 drives can be installed in 3.5" type base unit and drive enclosure.
2.5" Drive Enclosure cannot be added.
One 3.5" Drive Enclosures can be added.

- Contents of Package
Components
AC200V power cord
Rack mount kit
Safety Precautions
User Guide
Read me first

Quantity
2
1 set
1
1
1

Note
4m (NEMA L6-15P)

CD

10

ETERNUS DX60 S2, DX80 S2, DX90 S2


(2) ETERNUS DX60 S2 (single-controller type)

i) ETERNUS DX60 S2 base unit (Single controller type, Fibre Channel connection)
Product name
Product ID

Configuration

Notes

ETERNUS DX60 S2
ETERNUS DX60 S2
(2.5inch, 4Gbps, FC, Single-controller) (3.5inch, 4Gbps, FC, Single-controller)
ET062SCFU
ET062SDFU
Rackmount type (2U), AC200V model
Enclosure x1
- Controller (FC4Gbit/s x 2ports) x1
- Cache memory (1G) x1
- Power Supply Unit x2
At least two disk drives are mandatory. Up to 24 drives can be added.
Up to 24 drives can be installed in 2.5" type base unit.
Up to 12 drives can be installed in 3.5" type base unit and drive enclosure.
2.5" Drive Enclosure cannot be added.
One 3.5" Drive Enclosures can be added.

- Contents of Package
Components
AC200V power cord
Rack mount kit
Safety Precautions
User Guide
Read me first

Quantity
2
1 set
1
1
1

Note
4m (NEMA L6-15P)

CD

- Additional Controller module (ETERNUS DX60 S2 Fibre Channel connection)


ETERNUS DX60 S2 (2.5")
Additional controller module for DX60 S2 (2.5inch, 4Gbps, FC)
[Field]
ETEEC6CF-L
- Controller x1 (with FC 4Gbps 2port)
- Cache memory (1GB x1)

ETERNUS DX60 S2 (3.5")


Additional controller module for DX60 S2 (3.5inch, 4Gbps, FC)
[Field]
ETEEC6DF-L
- Controller x1 (with FC 4Gbps 2port)
- Cache memory (1GB x1)

11

ETERNUS DX60 S2, DX80 S2, DX90 S2


(2) ETERNUS DX60 S2 (single-controller type)

ii) ETERNUS DX60 S2 base unit (Single controller type, SAS connection)
Product name
Product ID

Configuration

Notes

ETERNUS DX60 S2
ETERNUS DX60 S2
(2.5inch, 3Gbps, SAS, Single(3.5inch, 3Gbps, SAS, SingleET062SCSU
ET062SDSU
Rackmount type (2U), AC200V model
Enclosure x1
- Controller (SAS x 2ports) x1
- Cache memory (1G) x1
- Power Supply Unit x2
At least two disk drives are mandatory. Up to 24 drives can be added.
Up to 24 drives can be installed in 2.5" type base unit.
Up to 12 drives can be installed in 3.5" type base unit and drive enclosure.
2.5" Drive Enclosure cannot be added.
One 3.5" Drive Enclosures can be added.

- Contents of Package
Components
AC200V power cord
Rack mount kit
Safety Precautions
User Guide
Read me first

Quantity
2
1 set
1
1
1

Note
4m (NEMA L6-15P)

CD

- Additional Controller module (ETERNUS DX60 S2 SAS connection)


ETERNUS DX60 S2 (2.5")
Additional controller module for DX60 S2 (2.5inch, 3Gbps, SAS)
[Field]
ETEEC6CS-L
- Controller x1 (with SAS 3Gbps 2port)
- Cache memory (1GB x1)

ETERNUS DX60 S2 (3.5")


Additional controller module for DX60 S2 (3.5inch, 3Gbps, SAS)
[Field]
ETEEC6DS-L
- Controller x1 (with SAS 3Gbps 2port)
- Cache memory (1GB x1)

12

ETERNUS DX60 S2, DX80 S2, DX90 S2


(2) ETERNUS DX60 S2 (single-controller type)

iii) ETERNUS DX60 S2 Base Unit (Single controller type, iSCSI connection)
Product name
Product ID

Configuration

Notes

ETERNUS DX60 S2
ETERNUS DX60 S2
(2.5inch, 1Gbps, iSCSI, Single(3.5inch, 1Gbps, iSCSI, SingleET062SCLU
ET062SDLU
Rackmount type (2U), AC200V model
Enclosure x1
- Controller (iSCSI x 2ports) x1
- Cache memory (1G) x1
- Power Supply Unit x2
At least two disk drives are mandatory. Up to 24 drives can be added.
Up to 24 drives can be installed in 2.5" type base unit.
Up to 12 drives can be installed in 3.5" type base unit and drive enclosure.
2.5" Drive Enclosure cannot be added.
One 3.5" Drive Enclosures can be added.

- Contents of Package
Components
AC200V power cord
Rack mount kit
Safety Precautions
User Guide
Read me first

Quantity
2
1 set
1
1
1

Note
4m (NEMA L6-15P)

CD

- Additional Controller module (ETERNUS DX60 S2 iSCSI connection)


ETERNUS DX60 S2 (2.5")
Additional controller module for DX60 S2 (2.5inch, 1Gbps, iSCSI)
[Field]
ETEEC6CL-L
- Controller x1 (with iSCSI 1Gbps 2port)
- Cache memory (1GB x1)

ETERNUS DX60 S2 (3.5")


Additional controller module for DX60 S2 (3.5inch, 1Gbps, iSCSI)
[Field]
ETEEC6DL-L
- Controller x1 (with iSCSI 1Gbps 2port)
- Cache memory (1GB x1)

13

ETERNUS DX60 S2, DX80 S2, DX90 S2


(3) ETERNUS DX80 S2 (dual-controller type)

- ETERNUS DX80 S2 base unit (dual-controller type)


Product name
Product ID

Configuration

Notes

ETERNUS DX80 S2
ETERNUS DX80 S2
(2.5inch, dual-controller type)
(3.5inch, dual-controller type)
ET082DCU
ET082DDU
Rackmount type (2U), AC200V model
Enclosure x1
- Controller x2
- Cache memory (2G) x2
- Power Supply Unit x2
- Two sets of Host Interfaces are mandatory.
- Up to 24 drives can be installed in 2.5" type.
Up to 12 drives can be installed in 3.5" type.
- At least two disk drives are mandatory. Up to 120 drives can be added.
- Up to nine 3.5" or four 2.5" Drive Enclosures can be added.

- Contents of Package
Components
AC200V power cord
Rack mount kit
Safety Precautions
User Guide
Read me first

Quantity
2
1 set
1
1
1

Note
4m (NEMA L6-15P)

CD

14

ETERNUS DX60 S2, DX80 S2, DX90 S2


(3) ETERNUS DX80 S2 (dual-controller type)
- Host interface (ETERNUS DX80 S2)
ETERNUS DX80 S2

Two host interface options are mandatory. (Four host ports are mandatory.)
Up to four options can be installed. (Up to eight ports can be installed.)
Either two or four options should be same type. (Either four or eight ports should be same type.)
Mixing different interfaces is supported.

Host interface for DX80 S2/DX90 S2 (FC 16G, 2port)


[Factory] ETEHH12
- Host interface module (FC 16G) x1
- SFP+ (16Gbit/s) module x2
Host interface for DX80 S2/DX90 S2 (FC 16G, 2port)
[Field] ETEHH12-L
- Host interface module (FC 16G) x1
- SFP+ (16Gbit/s) module x2
Host interface for DX80 S2/DX90 S2 (FC 8G, 2port)
[Factory] ETEHF12
- Host interface module (FC 8G) x1
- SFP+ (8Gbit/s) module x2
Host interface for DX80 S2/DX90 S2 (FC 8G, 2port)
[Field] ETEHF12-L
- Host interface module (FC 8G) x1
- SFP+ (8Gbit/s) module x2
Host interface for DX80 S2/DX90 S2 (SAS, 2port)
[Factory] ETEHS12
- Host interface module (SAS) x1
Host interface for DX80 S2/DX90 S2 (SAS, 2port)
[Field] ETEHS12-L
- Host interface module (SAS) x1
Host interface for DX80 S2/DX90 S2 (1Gbit/s, iSCSI, 2port)
[Factory] ETEHL12
- Host interface module (iSCSI 1G) x1
Host interface for DX80 S2/DX90 S2 (1Gbit/s, iSCSI, 2port)
[Field] ETEHL12-L
- Host interface module (iSCSI 1G) x1
Host interface for DX80 S2/DX90 S2 (10Gbit/s, iSCSI, 2port, for optical cable)
[Factory] ETEHY12
- Host interface module (iSCSI 10G) x1
- SFP+ (10Gbit/s) x2
Host interface for DX80 S2/DX90 S2 (10Gbit/s, iSCSI, 2port, for optical cable)
[Field] ETEHY12-L
- Host interface module (iSCSI 10G) x1
- SFP+ (10Gbit/s) x2
Host interface for DX80 S2/DX90 S2 (10Gbit/s, iSCSI, 2port, without SFP+, for copper cable)
[Factory] ETEHY1N
- Host interface module (iSCSI 10G) x1
Host interface for DX80 S2/DX90 S2 (10Gbit/s, iSCSI, 2port, without SFP+, for copper cable)
[Field] ETEHY1N-L
- Host interface module (iSCSI 10G) x1
15

ETERNUS DX60 S2, DX80 S2, DX90 S2


(3) ETERNUS DX80 S2 (dual-controller type)
Host interface for DX80 S2/DX90 S2 (FCoE, 2port, for optical cable)
[Factory] ETEHC12
- Host interface module (FCoE) x1
- SFP+ (10Gbit/s) x2
Host interface for DX80 S2/DX90 S2 (FCoE, 2port, for optical cable)
[Field] ETEHC12-L
- Host interface module (FCoE) x1
- SFP+ (10Gbit/s) x2
Host interface for DX80 S2/DX90 S2 (FCoE, 2port, without SFP+, for copper cable)
[Factory] ETEHC1N
- Host interface module (FCoE) x1
Host interface for DX80 S2/DX90 S2 (FCoE, 2port, without SFP+, for copper cable)
[Field] ETEHC1N-L
- Host interface module (FCoE) x1
[Factory]: Factory mount option
[Field]: Field upgrade option

16

ETERNUS DX60 S2, DX80 S2, DX90 S2


(4) ETERNUS DX80 S2 (Single-controller type)

- ETERNUS DX80 S2 base unit (single-controller type)


Product name
Product ID

Configuration

Notes

ETERNUS DX80 S2
ETERNUS DX80 S2
(2.5inch, single-controller type)
(3.5inch, single-controller type)
ET082SCU
ET082SDU
Rackmount type (2U), AC200V model
Enclosure x1
- Controller x1
- Cache memory (2G) x1
- Power Supply Unit x2
- One Host Interface set is mandatory.
No additional controller can be installed in the base unit of the single controller
model at the time of shipment.
- Up to 24 drives can be installed in 2.5" type.
Up to 12 drives can be installed in 3.5" type.
- At least two disk drives are mandatory. Up to 120 drives can be added.
- Up to nine 3.5" or four 2.5" Drive Enclosures can be added.

- Contents of Package
Components
AC200V power cord
Rack mount kit
Safety Precautions
User Guide
Read me first

Quantity
2
1 set
1
1
1

Note
4m (NEMA L6-15P)

CD

'- Additional Controller module (ETERNUS DX80 S2)


ETERNUS DX80 S2

One Controller module can be added on single-controller type.

Additional controller module for DX80 S2


[Field] ETEAC8A-L
- Controller x1
- Cache memory (2GB x1)

17

ETERNUS DX60 S2, DX80 S2, DX90 S2


(4) ETERNUS DX80 S2 (Single-controller type)
- Host interface (ETERNUS DX80 S2)
ETERNUS DX80 S2

One host interface option is mandatory. (Two host ports are mandatory.)
Up to two options can be installed for single CM model. (Up to four ports can be installed.)
Mixing different interfaces is supported for single CM model.
Up to four options can be installed for dual CM model. (Up to eight ports can be installed.)
Either two or four options should be same type for dual CM model.
(Either four or eight ports should be same type for dual CM model.)

Host interface for DX80 S2/DX90 S2 (FC 16G, 2port)


[Factory] ETEHH12
- Host interface module (FC 16G) x1
- SFP+ (16Gbit/s) module x2
Host interface for DX80 S2/DX90 S2 (FC 16G, 2port)
[Field] ETEHH12-L
- Host interface module (FC 16G) x1
- SFP+ (16Gbit/s) module x2
Host interface for DX80 S2/DX90 S2 (FC 8G, 2port)
[Factory] ETEHF12
- Host interface module (FC 8G) x1
- SFP+ (8Gbit/s) module x2
Host interface for DX80 S2/DX90 S2 (FC 8G, 2port)
[Field] ETEHF12-L
- Host interface module (FC 8G) x1
- SFP+ (8Gbit/s) module x2
Host interface for DX80 S2/DX90 S2 (SAS, 2port)
[Factory] ETEHS12
- Host interface module (SAS) x1
Host interface for DX80 S2/DX90 S2 (SAS, 2port)
[Field] ETEHS12-L
- Host interface module (SAS) x1
Host interface for DX80 S2/DX90 S2 (1Gbit/s, iSCSI, 2port)
[Factory] ETEHL12
- Host interface module (iSCSI 1G) x1
Host interface for DX80 S2/DX90 S2 (1Gbit/s, iSCSI, 2port)
[Field] ETEHL12-L
- Host interface module (iSCSI 1G) x1
Host interface for DX80 S2/DX90 S2 (10Gbit/s, iSCSI, 2port, for optical cable)
[Factory] ETEHY12
- Host interface module (iSCSI 10G) x1
- SFP+ (10Gbit/s) x2
Host interface for DX80 S2/DX90 S2 (10Gbit/s, iSCSI, 2port, for optical cable)
[Field] ETEHY12-L
- Host interface module (iSCSI 10G) x1
- SFP+ (10Gbit/s) x2
Host interface for DX80 S2/DX90 S2 (10Gbit/s, iSCSI, 2port, without SFP+, for copper cable)
[Factory] ETEHY1N
- Host interface module (iSCSI 10G) x1
Host interface for DX80 S2/DX90 S2 (10Gbit/s, iSCSI, 2port, without SFP+, for copper cable)
[Field] ETEHY1N-L
- Host interface module (iSCSI 10G)18
x1

ETERNUS DX60 S2, DX80 S2, DX90 S2


(4) ETERNUS DX80 S2 (Single-controller type)
Host interface for DX80 S2/DX90 S2 (FCoE, 2port, for optical cable)
[Factory] ETEHC12
- Host interface module (FCoE) x1
- SFP+ (10Gbit/s) x2
Host interface for DX80 S2/DX90 S2 (FCoE, 2port, for optical cable)
[Field] ETEHC12-L
- Host interface module (FCoE) x1
- SFP+ (10Gbit/s) x2
Host interface for DX80 S2/DX90 S2 (FCoE, 2port, without SFP+, for copper cable)
[Factory] ETEHC1N
- Host interface module (FCoE) x1
Host interface for DX80 S2/DX90 S2 (FCoE, 2port, without SFP+, for copper cable)
[Field] ETEHC1N-L
- Host interface module (FCoE) x1
[Factory]: Factory mount option
[Field]: Field upgrade option

19

ETERNUS DX60 S2, DX80 S2, DX90 S2


(5) ETERNUS DX90 S2 (dual-controller type)

- ETERNUS DX90 S2 base unit (dual-controller type)


Product name
Product ID

Configuration

Notes

ETERNUS DX90 S2
ETERNUS DX90 S2
(2.5inch, dual-controller type)
(3.5inch, dual-controller type)
ET092DCU
ET092DDU
Rackmount type (2U), AC200V
Enclosure x1
- Controller x2
- Cache memory (4GB) x2
- Power Supply Unit x2
- Two sets of the same Host Interface are mandatory.
Up to 24 drives can be installed in 2.5" type.
Up to 12 drives can be installed in 3.5" type.
- At least two disk drives are mandatory. Up to 240 2.5" drives can be added.
Up to 120 3.5" drives can be added.
- Up to nine Drive Enclosures(2.5"/3.5") can be added.

- Contents of Package
Components
AC200V power cord
Rack mount kit
Safety Precautions
User Guide
Read me first

Quantity
2
1 set
1
1
1

Note
4m (NEMA L6-15P)

CD

20

ETERNUS DX60 S2, DX80 S2, DX90 S2


(5) ETERNUS DX90 S2 (dual-controller type)
- Host interface (ETERNUS DX90 S2)
ETERNUS DX90 S2

Two host ports are mandatory. (Four ports host interface are mandatory.)
Up to four options can be installed. (Up to eight ports can be installed.)
Either two or four options should be same type. (Either four or eight ports should be same type.)
Mixing different interfaces is supported.

Host interface for DX80 S2/DX90 S2 (FC 16G, 2port)


[Factory] ETEHH12
- Host interface module (FC 16G) x1
- SFP+ (16Gbit/s) module x2
Host interface for DX80 S2/DX90 S2 (FC 16G, 2port)
[Field] ETEHH12-L
- Host interface module (FC 16G) x1
- SFP+ (16Gbit/s) module x2
Host interface for DX80 S2/DX90 S2 (FC 8G, 2port)
[Factory] ETEHF12
- Host interface module (FC 8G) x1
- SFP+ (8Gbit/s) module x2
Host interface for DX80 S2/DX90 S2 (FC 8G, 2port)
[Field] ETEHF12-L
- Host interface module (FC 8G) x1
- SFP+ (8Gbit/s) module x2
Host interface for DX80 S2/DX90 S2 (SAS, 2port)
[Factory] ETEHS12
- Host interface module (SAS) x1
Host interface for DX80 S2/DX90 S2 (SAS, 2port)
[Field] ETEHS12-L
- Host interface module (SAS) x1
Host interface for DX80 S2/DX90 S2 (1Gbit/s, iSCSI, 2port)
[Factory] ETEHL12
- Host interface module (iSCSI 1G) x1
Host interface for DX80 S2/DX90 S2 (1Gbit/s, iSCSI, 2port)
[Field] ETEHL12-L
- Host interface module (iSCSI 1G) x1
Host interface for DX80 S2/DX90 S2 (10Gbit/s, iSCSI, 2port, for optical cable)
[Factory] ETEHY12
- Host interface module (iSCSI 10G) x1
- SFP+ (10Gbit/s) x2
Host interface for DX80 S2/DX90 S2 (10Gbit/s, iSCSI, 2port, for optical cable)
[Field] ETEHY12-L
- Host interface module (iSCSI 10G) x1
- SFP+ (10Gbit/s) x2
Host interface for DX80 S2/DX90 S2 (10Gbit/s, iSCSI, 2port, without SFP+, for copper cable)
[Factory] ETEHY1N
- Host interface module (iSCSI 10G) x1
Host interface for DX80 S2/DX90 S2 (10Gbit/s, iSCSI, 2port, without SFP+, for copper cable)
[Field] ETEHY1N-L
- Host interface module (iSCSI 10G) x1
21

ETERNUS DX60 S2, DX80 S2, DX90 S2


(5) ETERNUS DX90 S2 (dual-controller type)
Host interface for DX80 S2/DX90 S2 (FCoE, 2port, for optical cable)
[Factory] ETEHC12
- Host interface module (FCoE) x1
- SFP+ (10Gbit/s) x2
Host interface for DX80 S2/DX90 S2 (FCoE, 2port, for optical cable)
[Field] ETEHC12-L
- Host interface module (FCoE) x1
- SFP+ (10Gbit/s) x2
Host interface for DX80 S2/DX90 S2 (FCoE, 2port, without SFP+, for copper cable)
[Factory] ETEHC1N
- Host interface module (FCoE) x1
Host interface for DX80 S2/DX90 S2 (FCoE, 2port, without SFP+, for copper cable)
[Field] ETEHC1N-L
- Host interface module (FCoE) x1
[Factory]: Factory mount option
[Field]: Field upgrade option

22

ETERNUS DX60 S2, DX80 S2, DX90 S2


(6) ETERNUS DX90 S2 (single-controller type)

- ETERNUS DX90 S2 base unit (single-controller type)


Product name
Product ID

Configuration

Notes

ETERNUS DX90 S2
ETERNUS DX90 S2
(2.5inch, single-controller type)
(3.5inch, single-controller type)
ET092SCU
ET092SDU
Rackmount type (2U), AC200V
Enclosure x1
- Controller x1
- Cache memory (4GB) x1
- Power Supply Unit x2
- One set of the same Host Interfaces are mandatory.
No additional controller can be installed in the base unit of the single controller
model at the time of shipment.
- Up to 24 drives can be installed in 2.5" type.
Up to 12 drives can be installed in 3.5" type.
- At least two disk drives are mandatory. Up to 240 2.5" drives can be added.
Up to 120 3.5" drives can be added.
- Up to nine 3.5" or four 2.5" Drive Enclosures can be added.

- Contents of Package
Components
AC200V power cord
Rack mount kit
Safety Precautions
User Guide
Read me first

Quantity
2
1 set
1
1
1

Note
4m (NEMA L6-15P)

CD

- Additional Controller module (ETERNUS DX90 S2)


ETERNUS DX90 S2

One Controller module can be added on single-controller type.

Additional controller module for DX90 S2


[Field] ETEAC9A-L
- Controller x1
- Cache memory (4GB x1)

23

ETERNUS DX60 S2, DX80 S2, DX90 S2


(6) ETERNUS DX90 S2 (single-controller type)
- Host interface (ETERNUS DX90 S2)
ETERNUS DX90 S2

One host interface option is mandatory. (Two host ports are mandatory.)
Up to two options can be installed for single CM model. (Up to four ports can be installed.)
Mixing different interfaces is supported for single CM model.
Up to four options can be installed for dual CM model. (Up to eight ports can be installed.)
Either two or four options should be same type for dual CM model.
(Either four or eight ports should be same type for dual CM model.)

Host interface for DX80 S2/DX90 S2 (FC 16G, 2port)


[Factory] ETEHH12
- Host interface module (FC 16G) x1
- SFP+ (16Gbit/s) module x2
Host interface for DX80 S2/DX90 S2 (FC 16G, 2port)
[Field] ETEHH12-L
- Host interface module (FC 16G) x1
- SFP+ (16Gbit/s) module x2
Host interface for DX80 S2/DX90 S2 (FC 8G, 2port)
[Factory] ETEHF12
- Host interface module (FC 8G) x1
- SFP+ (8Gbit/s) module x2
Host interface for DX80 S2/DX90 S2 (FC 8G, 2port)
[Field] ETEHF12-L
- Host interface module (FC 8G) x1
- SFP+ (8Gbit/s) module x2
Host interface for DX80 S2/DX90 S2 (SAS, 2port)
[Factory] ETEHS12
- Host interface module (SAS) x1
Host interface for DX80 S2/DX90 S2 (SAS, 2port)
[Field] ETEHS12-L
- Host interface module (SAS) x1
Host interface for DX80 S2/DX90 S2 (1Gbit/s, iSCSI, 2port)
[Factory] ETEHL12
- Host interface module (iSCSI 1G) x1
Host interface for DX80 S2/DX90 S2 (1Gbit/s, iSCSI, 2port)
[Field] ETEHL12-L
- Host interface module (iSCSI 1G) x1
Host interface for DX80 S2/DX90 S2 (10Gbit/s, iSCSI, 2port, for optical cable)
[Factory] ETEHY12
- Host interface module (iSCSI 10G) x1
- SFP+ (10Gbit/s) x2
Host interface for DX80 S2/DX90 S2 (10Gbit/s, iSCSI, 2port, for optical cable)
[Field] ETEHY12-L
- Host interface module (iSCSI 10G) x1
- SFP+ (10Gbit/s) x2
Host interface for DX80 S2/DX90 S2 (10Gbit/s, iSCSI, 2port, without SFP+, for copper cable)
[Factory] ETEHY1N
- Host interface module (iSCSI 10G) x1
Host interface for DX80 S2/DX90 S2 (10Gbit/s, iSCSI, 2port, without SFP+, for copper cable)
[Field] ETEHY1N-L
- Host interface module (iSCSI 10G)24
x1

ETERNUS DX60 S2, DX80 S2, DX90 S2


(6) ETERNUS DX90 S2 (single-controller type)
Host interface for DX80 S2/DX90 S2 (FCoE, 2port, for optical cable)
[Factory] ETEHC12
- Host interface module (FCoE) x1
- SFP+ (10Gbit/s) x2
Host interface for DX80 S2/DX90 S2 (FCoE, 2port, for optical cable)
[Field] ETEHC12-L
- Host interface module (FCoE) x1
- SFP+ (10Gbit/s) x2
Host interface for DX80 S2/DX90 S2 (FCoE, 2port, without SFP+, for copper cable)
[Factory] ETEHC1N
- Host interface module (FCoE) x1
Host interface for DX80 S2/DX90 S2 (FCoE, 2port, without SFP+, for copper cable)
[Field] ETEHC1N-L
- Host interface module (FCoE) x1
[Factory]: Factory mount option
[Field]: Field upgrade option

25

ETERNUS DX60 S2, DX80 S2, DX90 S2


(7) Options
- Disk drive option (2.5inch disk drive)
* 2.5inch drives are installed in the 2.5inch type controller enclosure
ETERNUS DX60 S2
Disk drive
2.5inch disk drive
* Mandatory option
* Up to 24 drives can be installed in a 2.5inch base unit.
2.5inch 10krpm SAS disk drive
Factory mount options
Product name
Disk Drive(2.5inch) 300GB 10krpm x2 (RAID1) for DX60 S2
Disk Drive(2.5inch) 300GB 10krpm x6 (RAID5) for DX60 S2
Disk Drive(2.5inch) 300GB 10krpm x6 (RAID6) for DX60 S2
Disk Drive(2.5inch) 300GB 10krpm x6 (RAID1+0) for DX60 S2
Disk Drive(2.5inch) 300GB 10krpm x1 for DX60 S2
Disk Drive(2.5inch) 450GB 10krpm x2 (RAID1) for DX60 S2
Disk Drive(2.5inch) 450GB 10krpm x6 (RAID5) for DX60 S2
Disk Drive(2.5inch) 450GB 10krpm x6 (RAID6) for DX60 S2
Disk Drive(2.5inch) 450GB 10krpm x6 (RAID1+0) for DX60 S2
Disk Drive(2.5inch) 450GB 10krpm x1 for DX60 S2
Disk Drive(2.5inch) 600GB 10krpm x2 (RAID1) for DX60 S2
Disk Drive(2.5inch) 600GB 10krpm x6 (RAID5) for DX60 S2
Disk Drive(2.5inch) 600GB 10krpm x6 (RAID6) for DX60 S2
Disk Drive(2.5inch) 600GB 10krpm x6 (RAID1+0) for DX60 S2
Disk Drive(2.5inch) 600GB 10krpm x1 for DX60 S2
Disk Drive(2.5inch) 900GB 10krpm x2 (RAID1) for DX60 S2
Disk Drive(2.5inch) 900GB 10krpm x6 (RAID5) for DX60 S2
Disk Drive(2.5inch) 900GB 10krpm x6 (RAID6) for DX60 S2
Disk Drive(2.5inch) 900GB 10krpm x6 (RAID1+0) for DX60 S2
Disk Drive(2.5inch) 900GB 10krpm x1 for DX60 S2
Field upgrade options
Disk Drive(2.5inch) 300GB 10krpm x1 for DX60 S2
Disk Drive(2.5inch) 450GB 10krpm x1 for DX60 S2
Disk Drive(2.5inch) 600GB 10krpm x1 for DX60 S2
Disk Drive(2.5inch) 900GB 10krpm x1 for DX60 S2

Product ID
ETED3MB
ETED3PB
ETED3DB
ETED3SB
ETED3HB
ETED4MB
ETED4PB
ETED4DB
ETED4SB
ETED4HB
ETED6MB
ETED6PB
ETED6DB
ETED6SB
ETED6HB
ETED9MB
ETED9PB
ETED9DB
ETED9SB
ETED9HB
ETED3HB-L
ETED4HB-L
ETED6HB-L
ETED9HB-L

2.5inch 7.2krpm SAS disk drive


Factory mount options
Product name
Disk Drive(2.5inch) 1TB 7.2krpm x2 (RAID1) for DX60 S2
Disk Drive(2.5inch) 1TB 7.2krpm x6 (RAID5) for DX60 S2
Disk Drive(2.5inch) 1TB 7.2krpm x6 (RAID6) for DX60 S2
Disk Drive(2.5inch) 1TB 7.2krpm x6 (RAID1+0) for DX60 S2
Disk Drive(2.5inch) 1TB 7.2krpm x1 for DX60 S2
Field upgrade options
Disk Drive(2.5inch) 1TB 7.2krpm x1 for DX60 S2

Product ID
ETEN1MB
ETEN1PB
ETEN1DB
ETEN1SB
ETEN1HB
ETEN1HB-L

#1 Two or more disk drives are mandatory for one base unit.
#2 Install hot spare disks for stable operation.
#3 A mixture of different size disk drives is supported.
The capacity of the hot spare disk should match the capacity of the largest disk drive.
Ex.) 450GB/10krpm SAS disk x6 (RAID5) x1,
600GB/10krpm SAS disk x6 (RAID5) x1
=> 600GB disk drive x1 is the hot spare.
#4 A mixture of different disk drives cannot be used for a single RAID group. Same type disk drives
(same capacity, rotation speed and interface speed) are required.

26

ETERNUS DX60 S2, DX80 S2, DX90 S2


(7) Options
- Disk drive option (3.5inch disk drive)
ETERNUS DX60 S2
Disk drive
3.5inch disk drive
* Mandatory option
* Up to 12 drives can be installed in a 3.5inch base unit or a 3.5inch drive enclosure.
Factory mount options
Product name
Disk Drive(3.5inch) 300GB 15krpm x1 for DX60 S2
Disk Drive(3.5inch) 300GB 15krpm x6 (RAID5) for DX60 S2
Disk Drive(3.5inch) 300GB 15krpm x6 (RAID6) for DX60 S2
Disk Drive(3.5inch) 300GB 15krpm x6 (RAID1+0) for DX60 S2
Disk Drive(3.5inch) 300GB 15krpm x2 (RAID1) for DX60 S2
Disk Drive(3.5inch) 450GB 15krpm x2 (RAID1) for DX60 S2
Disk Drive(3.5inch) 450GB 15krpm x6 (RAID5)for DX60 S2
Disk Drive(3.5inch) 450GB 15krpm x6 (RAID6) for DX60 S2
Disk Drive(3.5inch) 450GB 15krpm x6 (RAID1+0) for DX60 S2
Disk Drive(3.5inch) 450GB 15krpm x1 for DX60 S2
Disk Drive(3.5inch) 600GB 15krpm x2 (RAID1) for DX60 S2
Disk Drive(3.5inch) 600GB 15krpm x6 (RAID5) for DX60 S2
Disk Drive(3.5inch) 600GB 15krpm x6 (RAID6) for DX60 S2
Disk Drive(3.5inch) 600GB 15krpm x6 (RAID1+0) for DX60 S2
Disk Drive(3.5inch) 600GB 15krpm x1 for DX60 S2
Disk Drive(3.5inch) 1TB 7.2krpm x2 (RAID1) for DX60 S2
Disk Drive(3.5inch) 1TB 7.2krpm x6 (RAID5) for DX60 S2
Disk Drive(3.5inch) 1TB 7.2krpm x6 (RAID6) for DX60 S2
Disk Drive(3.5inch) 1TB 7.2krpm x6 (RAID1+0) for DX60 S2
Disk Drive(3.5inch) 1TB 7.2krpm x1 for DX60 S2
Disk Drive(3.5inch) 2TB 7.2krpm x2 (RAID1) for DX60 S2
Disk Drive(3.5inch) 2TB 7.2krpm x6 (RAID5) for DX60 S2
Disk Drive(3.5inch) 2TB 7.2krpm x6 (RAID6) for DX60 S2
Disk Drive(3.5inch) 2TB 7.2krpm x6 (RAID1+0) for DX60 S2
Disk Drive(3.5inch) 2TB 7.2krpm x1 for DX60 S2
Disk Drive(3.5inch) 3TB 7.2krpm x2 (RAID1) for DX60 S2
Disk Drive(3.5inch) 3TB 7.2krpm x6 (RAID5) for DX60 S2
Disk Drive(3.5inch) 3TB 7.2krpm x6 (RAID6) for DX60 S2
Disk Drive(3.5inch) 3TB 7.2krpm x6 (RAID1+0) for DX60 S2
Disk Drive(3.5inch) 3TB 7.2krpm x1 for DX60 S2
Field upgrade options
Disk Drive(3.5inch) 300GB 15krpm x1 for DX60 S2
Disk Drive(3.5inch) 450GB 15krpm x1 for DX60 S2
Disk Drive(3.5inch) 600GB 15krpm x1 for DX60 S2
Disk Drive(3.5inch) 1TB 7.2krpm x1 for DX60 S2
Disk Drive(3.5inch) 2TB 7.2krpm x1 for DX60 S2
Disk Drive(3.5inch) 3TB 7.2krpm x1 for DX60 S2

Product ID
ETED3HA
ETED3PA
ETED3DA
ETED3SA
ETED3MA
ETED4MA
ETED4PA
ETED4DA
ETED4SA
ETED4HA
ETED6MA
ETED6PA
ETED6DA
ETED6SA
ETED6HA
ETEN1MA
ETEN1PA
ETEN1DA
ETEN1SA
ETEN1HA
ETEN2MA
ETEN2PA
ETEN2DA
ETEN2SA
ETEN2HA
ETEN3MA
ETEN3PA
ETEN3DA
ETEN3SA
ETEN3HA
ETED3HA-L
ETED4HA-L
ETED6HA-L
ETEN1HA-L
ETEN2HA-L
ETEN3HA-L

#1 Two or more disk drives are mandatory for one base unit.
#2 Install hot spare disks for stable operation.
#3 A mixture of different capacity disk drives is supported.
When installing different capacity disk drives in one base unit,
the capacity of the hot spare disk should match the capacity of the largest disk drive.
Ex.) 450GB/15krpm SAS disk x6 (RAID5) x1, 600GB/15krpm SAS disk x6 (RAID5) x1
=> 600GB disk drive x1 is the hot spare.
#4 A mixture of different disks (SAS disk drives and Nearline SAS disk drives) is supported.
When installing different type disk drives in one base unit,
it is recommended that at least one hot spare disk of each type be installed.
#5 A mixture of different disk drives cannot be used for a single RAID group. Same type disk drives
(same capacity, rotation speed and interface speed) are required.
27

ETERNUS DX60 S2, DX80 S2, DX90 S2


(7) Options
- Drive enclosure (3.5inch)
ETERNUS DX60 S2

Dual-IOM type supports dual controller model only.

Drive enclosure for DX60 S2 (3.5inch, dual-expander type)


[Factory] ETEED2DU
[Field] ETEED2DU-L
- Rack mount type (2U)
- Enclosure [Expander (SAS 1port) x2, PSU x2] x1
- Up to 12 disk drives can be installed in one drive enclosure.
- Attachment list
Attachment
Notes
Qty
Rackmount kit
1 set
AC200V power cable
2
4m (NEMA L6-15P)
SAS cable
2
75cm: Bace unit <=>
Drive enclosure connection
Disk drive
Refer "Disk drive option (3.5inch)"
* Up to 12 disk drives can be installed.

Drive enclosure for DX60 S2 (3.5inch, single-expander type)


[Factory] ETEED1DU
[Field] ETEED1DU-L
- Rack mount type (2U)
- Enclosure [Expander (SAS 1port) x1, PSU x2] x1
- Up to 12 disk drives can be installed in one drive enclosure.
- Attachment list
Attachment
Notes
Qty
Rackmount kit
1 set
AC200V power cable
2
4m (NEMA L6-15P)
SAS cable
1
75cm: Bace unit <=>
Drive enclosure connection
Additional expander for DX60 S2 (3.5inch)
[Field] ETEEXD-L
- Attachment list
Attachment
Notes
Qty
IOM
1
SAS cable
1
75cm: Bace unit <=>
Drive enclosure connection

Disk drive
Refer "Disk drive option (3.5inch)"
* Up to 12 disk drives can be installed.

- Extension cable
ETERNUS DX60 S2
- The Extension cable (3m) kit option can be ordered if the SAS cables (75cm)
supplied with the drive enclosures are too short to connect.
Extension cable between enclosures for DX60 S2 (3m)
[Field] ETEC1M3-L
28
- 1x mini SAS cable 3m

ETERNUS DX60 S2, DX80 S2, DX90 S2


(7) Options
- Disk drive option (2.5inch disk drive)
* 2.5inch drives are installed in the 2.5inch type controller enclosure and drive enclosures.
ETERNUS DX80 S2, DX90
Disk drive
2.5inch disk drive
* Mandatory option
* Up to 24 drives can be installed in a 2.5inch base unit or a 2.5inch drive enclosure.
2.5inch 10krpm SAS disk drive
Factory mount options
Product name
Disk Drive(2.5inch) 300GB 10krpm x2 (RAID1) for DX80 S2/DX90 S2
Disk Drive(2.5inch) 300GB 10krpm x6 (RAID5) for DX80 S2/DX90 S2
Disk Drive(2.5inch) 300GB 10krpm x6 (RAID6) for DX80 S2/DX90 S2
Disk Drive(2.5inch) 300GB 10krpm x6 (RAID1+0) for DX80 S2/DX90 S2
Disk Drive(2.5inch) 300GB 10krpm x1 for DX80 S2/DX90 S2
Disk Drive(2.5inch) 450GB 10krpm x2 (RAID1) for DX80 S2/DX90 S2
Disk Drive(2.5inch) 450GB 10krpm x6 (RAID5) for DX80 S2/DX90 S2
Disk Drive(2.5inch) 450GB 10krpm x6 (RAID6) for DX80 S2/DX90 S2
Disk Drive(2.5inch) 450GB 10krpm x6 (RAID1+0) for DX80 S2/DX90 S2
Disk Drive(2.5inch) 450GB 10krpm x1 for DX80 S2/DX90 S2
Disk Drive(2.5inch) 600GB 10krpm x2 (RAID1) for DX80 S2/DX90 S2
Disk Drive(2.5inch) 600GB 10krpm x6 (RAID5) for DX80 S2/DX90 S2
Disk Drive(2.5inch) 600GB 10krpm x6 (RAID6) for DX80 S2/DX90 S2
Disk Drive(2.5inch) 600GB 10krpm x6 (RAID1+0) for DX80 S2/DX90 S2
Disk Drive(2.5inch) 600GB 10krpm x1 for DX80 S2/DX90 S2
Disk Drive(2.5inch) 900GB 10krpm x2 (RAID1) for DX80 S2/DX90 S2
Disk Drive(2.5inch) 900GB 10krpm x6 (RAID5) for DX80 S2/DX90 S2
Disk Drive(2.5inch) 900GB 10krpm x6 (RAID6) for DX80 S2/DX90 S2
Disk Drive(2.5inch) 900GB 10krpm x6 (RAID1+0) for DX80 S2/DX90 S2
Disk Drive(2.5inch) 900GB 10krpm x1 for DX80 S2/DX90 S2
Field upgrade options
Disk Drive(2.5inch) 300GB 10krpm x1 for DX80 S2/DX90 S2
Disk Drive(2.5inch) 450GB 10krpm x1 for DX80 S2/DX90 S2
Disk Drive(2.5inch) 600GB 10krpm x1 for DX80 S2/DX90 S2
Disk Drive(2.5inch) 900GB 10krpm x1 for DX80 S2/DX90 S2

Product ID
ETED3MC
ETED3PC
ETED3DC
ETED3SC
ETED3HC
ETED4MC
ETED4PC
ETED4DC
ETED4SC
ETED4HC
ETED6MC
ETED6PC
ETED6DC
ETED6SC
ETED6HC
ETED9MC
ETED9PC
ETED9DC
ETED9SC
ETED9HC
ETED3HC-L
ETED4HC-L
ETED6HC-L
ETED9HC-L

2.5inch 15krpm SAS disk drive


Factory mount options
Product name
Disk Drive (2.5inch) 300GB 15krpm x2 (RAID1) for DX80 S2/DX90 S2
Disk Drive (2.5inch) 300GB 15krpm x6 (RAID5) for DX80 S2/DX90 S2
Disk Drive (2.5inch) 300GB 15krpm x6 (RAID6) for DX80 S2/DX90 S2
Disk Drive (2.5inch) 300GB 15krpm x6 (RAID1+0) for DX80 S2/DX90 S2
Disk Drive (2.5inch) 300GB 15krpm x1 for DX80 S2/DX90 S2
Field upgrade options
Disk Drive (2.5inch) 300GB 15krpm x1 for DX80 S2/DX90 S2

Product ID
ETED3MG
ETED3PG
ETED3DG
ETED3SG
ETED3HG
ETED3HG-L

2.5inch 7.2krpm SAS disk drive


Factory mount options
Product name
Disk Drive (2.5inch) 1TB 7.2krpm x2 (RAID1) for DX80 S2/DX90 S2
Disk Drive (2.5inch) 1TB 7.2krpm x6 (RAID5) for DX80 S2/DX90 S2
Disk Drive (2.5inch) 1TB 7.2krpm x6 (RAID6) for DX80 S2/DX90 S2
Disk Drive (2.5inch) 1TB 7.2krpm x6 (RAID1+0) for DX80 S2/DX90 S2
Disk Drive (2.5inch) 1TB 7.2krpm x1 for DX80 S2/DX90 S2
Field upgrade options
Disk Drive (2.5inch) 1TB 7.2krpm x1 for DX80 S2/DX90 S2
29

Product ID
ETEN1MC
ETEN1PC
ETEN1DC
ETEN1SC
ETEN1HC
ETEN1HC-L

ETERNUS DX60 S2, DX80 S2, DX90 S2


(7) Options
Self Encrypting Disk Drive, 2.5inch 10krpm SAS disk drive
Factory mount options
Product name
Self Encrypting Disk Drive (2.5inch) 300GB 10krpm x2 (RAID1) for DX80 S2/DX90 S2
Self Encrypting Disk Drive (2.5inch) 300GB 10krpm x6 (RAID5) for DX80 S2/DX90 S2
Self Encrypting Disk Drive (2.5inch) 300GB 10krpm x6 (RAID6) for DX80 S2/DX90 S2
Self Encrypting Disk Drive (2.5inch) 300GB 10krpm x6 (RAID1+0) for DX80 S2/DX90 S2
Self Encrypting Disk Drive (2.5inch) 300GB 10krpm x1 for DX80 S2/DX90 S2
Self Encrypting Disk Drive (2.5inch) 450GB 10krpm x2 (RAID1) for DX80 S2/DX90 S2
Self Encrypting Disk Drive (2.5inch) 450GB 10krpm x6 (RAID5) for DX80 S2/DX90 S2
Self Encrypting Disk Drive (2.5inch) 450GB 10krpm x6 (RAID6) for DX80 S2/DX90 S2
Self Encrypting Disk Drive (2.5inch) 450GB 10krpm x6 (RAID1+0) for DX80 S2/DX90 S2
Self Encrypting Disk Drive (2.5inch) 450GB 10krpm x1 for DX80 S2/DX90 S2
Self Encrypting Disk Drive (2.5inch) 600GB 10krpm x2 (RAID1) for DX80 S2/DX90 S2
Self Encrypting Disk Drive (2.5inch) 600GB 10krpm x6 (RAID5) for DX80 S2/DX90 S2
Self Encrypting Disk Drive (2.5inch) 600GB 10krpm x6 (RAID6) for DX80 S2/DX90 S2
Self Encrypting Disk Drive (2.5inch) 600GB 10krpm x6 (RAID1+0) for DX80 S2/DX90 S2
Self Encrypting Disk Drive (2.5inch) 600GB 10krpm x1 for DX80 S2/DX90 S2
Self Encrypting Disk Drive (2.5inch) 900GB 10krpm x2 (RAID1) for DX80 S2/DX90 S2
Self Encrypting Disk Drive (2.5inch) 900GB 10krpm x6 (RAID5) for DX80 S2/DX90 S2
Self Encrypting Disk Drive (2.5inch) 900GB 10krpm x6 (RAID6) for DX80 S2/DX90 S2
Self Encrypting Disk Drive (2.5inch) 900GB 10krpm x6 (RAID1+0) for DX80 S2/DX90 S2
Self Encrypting Disk Drive (2.5inch) 900GB 10krpm x1 for DX80 S2/DX90 S2
Field upgrade options
Self Encrypting Disk Drive (2.5inch) 300GB 10krpm x1 for DX80 S2/DX90 S2
Self Encrypting Disk Drive (2.5inch) 450GB 10krpm x1 for DX80 S2/DX90 S2
Self Encrypting Disk Drive (2.5inch) 600GB 10krpm x1 for DX80 S2/DX90 S2
Self Encrypting Disk Drive (2.5inch) 900GB 10krpm x1 for DX80 S2/DX90 S2

Product ID
ETED3ME
ETED3PE
ETED3DE
ETED3SE
ETED3HE
ETED4ME
ETED4PE
ETED4DE
ETED4SE
ETED4HE
ETED6ME
ETED6PE
ETED6DE
ETED6SE
ETED6HE
ETED9ME
ETED9PE
ETED9DE
ETED9SE
ETED9HE
ETED3HE-L
ETED4HE-L
ETED6HE-L
ETED9HE-L

#1 Two or more disk drives are mandatory for one base unit.
#2 Install hot spare disks for stable operation.
#3 A mixture of different size disk drives is supported.
The capacity of the hot spare disk should match the capacity of the largest disk drive.
Ex.) 450GB/10krpm SAS disk x6 (RAID5) x1,
600GB/10krpm SAS disk x6 (RAID5) x1
=> 600GB disk drive x1 is the hot spare.
#4 A mixture of different disk drives cannot be used for a single RAID group. Same type disk drives
(same capacity, rotation speed and interface speed) are required.

30

ETERNUS DX60 S2, DX80 S2, DX90 S2


(7) Options
'- Disk drive option (3.5inch disk drive)
ETERNUS DX80 S2, DX90
Disk drive
3.5inch disk drive
* Mandatory option
* Up to 12 drives can be installed in a 3.5inch base unit or a 3.5inch drive enclosure.
Factory mount options
Product name
Disk Drive(3.5inch) 300GB 15krpm x2 (RAID1) for DX80 S2/DX90 S2
Disk Drive(3.5inch) 300GB 15krpm x6 (RAID5) for DX80 S2/DX90 S2
Disk Drive(3.5inch) 300GB 15krpm x6 (RAID6) for DX80 S2/DX90 S2
Disk Drive(3.5inch) 300GB 15krpm x6 (RAID1+0) for DX80 S2/DX90 S2
Disk Drive(3.5inch) 300GB 15krpm x1 for DX80 S2/DX90 S2
Disk Drive(3.5inch) 450GB 15krpm x2 (RAID1) for DX80 S2/DX90 S2
Disk Drive(3.5inch) 450GB 15krpm x6 (RAID5) for DX80 S2/DX90 S2
Disk Drive(3.5inch) 450GB 15krpm x6 (RAID6) for DX80 S2/DX90 S2
Disk Drive(3.5inch) 450GB 15krpm x6 (RAID1+0) for DX80 S2/DX90 S2
Disk Drive(3.5inch) 450GB 15krpm x1 for DX80 S2/DX90 S2
Disk Drive(3.5inch) 600GB 15krpm x2 (RAID1) for DX80 S2/DX90 S2
Disk Drive(3.5inch) 600GB 15krpm x6 (RAID5) for DX80 S2/DX90 S2
Disk Drive(3.5inch) 600GB 15krpm x6 (RAID6) for DX80 S2/DX90 S2
Disk Drive(3.5inch) 600GB 15krpm x6 (RAID1+0) for DX80 S2/DX90 S2
Disk Drive(3.5inch) 600GB 10krpm x1 for DX80 S2/DX90 S2
Disk Drive(3.5inch) 1TB 7.2krpm x2 (RAID1) for DX80 S2/DX90 S2
Disk Drive(3.5inch) 1TB 7.2krpm x6 (RAID5) for DX80 S2/DX90 S2
Disk Drive(3.5inch) 1TB 7.2krpm x6 (RAID6) for DX80 S2/DX90 S2
Disk Drive(3.5inch) 1TB 7.2krpm x6 (RAID1+0) for DX80 S2/DX90 S2
Disk Drive(3.5inch) 1TB 7.2krpm x1 for DX80 S2/DX90 S2
Disk Drive(3.5inch) 2TB 7.2krpm x2 (RAID1) for DX80 S2/DX90 S2
Disk Drive(3.5inch) 2TB 7.2krpm x6 (RAID5) for DX80 S2/DX90 S2
Disk Drive(3.5inch) 2TB 7.2krpm x6 (RAID6) for DX80 S2/DX90 S2
Disk Drive(3.5inch) 2TB 7.2krpm x6 (RAID1+0) for DX80 S2/DX90 S2
Disk Drive(3.5inch) 2TB 7.2krpm x1 for DX80 S2/DX90 S2
Disk Drive(3.5inch) 3TB 7.2krpm x2 (RAID1) for DX80 S2/DX90 S2
Disk Drive(3.5inch) 3TB 7.2krpm x6 (RAID5) for DX80 S2/DX90 S2
Disk Drive(3.5inch) 3TB 7.2krpm x6 (RAID6) for DX80 S2/DX90 S2
Disk Drive(3.5inch) 3TB 7.2krpm x6 (RAID1+0) for DX80 S2/DX90 S2
Disk Drive(3.5inch) 3TB 7.2krpm x1 for DX80 S2/DX90 S2
Field upgrade options
Disk Drive(3.5inch) 300GB 15krpm x1 for DX80 S2/DX90 S2
Disk Drive(3.5inch) 450GB 15krpm x1 for DX80 S2/DX90 S2
Disk Drive(3.5inch) 600GB 15krpm x1 for DX80 S2/DX90 S2
Disk Drive(3.5inch) 1TB 7.2krpm x1 for DX80 S2/DX90 S2
Disk Drive(3.5inch) 2TB 7.2krpm x1 for DX80 S2/DX90 S2
Disk Drive(3.5inch) 3TB 7.2krpm x1 for DX80 S2/DX90 S2

Product ID
ETED3MD
ETED3PD
ETED3DD
ETED3SD
ETED3HD
ETED4MD
ETED4PD
ETED4DD
ETED4SD
ETED4HD
ETED6MD
ETED6PD
ETED6DD
ETED6SD
ETED6HD
ETEN1MD
ETEN1PD
ETEN1DD
ETEN1SD
ETEN1HD
ETEN2MD
ETEN2PD
ETEN2DD
ETEN2SD
ETEN2HD
ETEN3MD
ETEN3PD
ETEN3DD
ETEN3SD
ETEN3HD
ETED3HD-L
ETED4HD-L
ETED6HD-L
ETEN1HD-L
ETEN2HD-L
ETEN3HD-L

#1 Two or more disk drives are mandatory for one base unit.
#2 Install hot spare disks for stable operation.
#3 A mixture of different capacity disk drives is supported.
When installing different capacity disk drives in one base unit,
the capacity of the hot spare disk should match the capacity of the largest disk drive.
Ex.) 450GB/15krpm SAS disk x6 (RAID5) x1, 600GB/15krpm SAS disk x6 (RAID5) x1
=> 600GB disk drive x1 is the hot spare.
#4 A mixture of different disks (SAS disk drives and Nearline SAS disk drives) is supported.
When installing different type disk drives in one base unit,
it is recommended that at least one hot spare disk of each type be installed.
#5 A mixture of different disk drives cannot be used for a single RAID group. Same type disk drives
(same capacity, rotation speed and interface speed) are required.
31

ETERNUS DX60 S2, DX80 S2, DX90 S2


(7) Options
- SSD
ETERNUS DX80 S2, DX90
SSD
2.5inch disk drives
Factory mount options
Product name
SSD(2.5inch) 100GB x2 (RAID1) for DX80 S2/DX90 S2
SSD(2.5inch) 100GB x4 (RAID5) for DX80 S2/DX90 S2
SSD(2.5inch) 100GB x6 (RAID1+0) for DX80 S2/DX90 S2
SSD(2.5inch) 100GB x1 for DX80 S2/DX90 S2
SSD(2.5inch) 200GB x2 (RAID1) for DX80 S2/DX90 S2
SSD(2.5inch) 200GB x4 (RAID5) for DX80 S2/DX90 S2
SSD(2.5inch) 200GB x6 (RAID1+0) for DX80 S2/DX90 S2
SSD(2.5inch) 200GB x1 for DX80 S2/DX90 S2
SSD(2.5inch) 400GB x2 (RAID1) for DX80 S2/DX90 S2
SSD(2.5inch) 400GB x4 (RAID5) for DX80 S2/DX90 S2
SSD(2.5inch) 400GB x6 (RAID1+0) for DX80 S2/DX90 S2
SSD(2.5inch) 400GB x1 for DX80 S2/DX90 S2
SSD(2.5inch) 800GB x2 (RAID1) for DX80 S2/DX90 S2
SSD(2.5inch) 800GB x4 (RAID5) for DX80 S2/DX90 S2
SSD(2.5inch) 800GB x6 (RAID1+0) for DX80 S2/DX90 S2
SSD(2.5inch) 800GB x1 for DX80 S2/DX90 S2
Field upgrade options
SSD(2.5inch) 100GB x1 for DX80 S2/DX90 S2
SSD(2.5inch) 200GB x1 for DX80 S2/DX90 S2
SSD(2.5inch) 400GB x1 for DX80 S2/DX90 S2
SSD(2.5inch) 800GB x1 for DX80 S2/DX90 S2
SSD
3.5inch disk drives
Factory mount options
SSD(3.5inch) 100GB x2 (RAID1) for DX80 S2/DX90 S2
SSD(3.5inch) 100GB x4 (RAID5) for DX80 S2/DX90 S2
SSD(3.5inch) 100GB x6 (RAID1+0) for DX80 S2/DX90 S2
SSD(3.5inch) 100GB x1 for DX80 S2/DX90 S2
SSD(3.5inch) 200GB x2 (RAID1) for DX80 S2/DX90 S2
SSD(3.5inch) 200GB x4 (RAID5) for DX80 S2/DX90 S2
SSD(3.5inch) 200GB x6 (RAID1+0) for DX80 S2/DX90 S2
SSD(3.5inch) 200GB x1 for DX80 S2/DX90 S2
SSD(3.5inch) 400GB x2 (RAID1) for DX80 S2/DX90 S2
SSD(3.5inch) 400GB x4 (RAID5) for DX80 S2/DX90 S2
SSD(3.5inch) 400GB x6 (RAID1+0) for DX80 S2/DX90 S2
SSD(3.5inch) 400GB x1 for DX80 S2/DX90 S2
SSD(3.5inch) 800GB x2 (RAID1) for DX80 S2/DX90 S2
SSD(3.5inch) 800GB x4 (RAID5) for DX80 S2/DX90 S2
SSD(3.5inch) 800GB x6 (RAID1+0) for DX80 S2/DX90 S2
SSD(3.5inch) 800GB x1 for DX80 S2/DX90 S2
Field upgrade options
SSD(3.5inch) 100GB x1 for DX80 S2/DX90 S2
SSD(3.5inch) 200GB x1 for DX80 S2/DX90 S2
SSD(3.5inch) 400GB x1 for DX80 S2/DX90 S2
SSD(3.5inch) 800GB x1 for DX80 S2/DX90 S2
* SSD supports RAID1, RAID1+0 and RAID5 only.

32

Product ID
ETES1MC
ETES1PC
ETES1SC
ETES1HC
ETES2MC
ETES2PC
ETES2SC
ETES2HC
ETES4MC
ETES4PC
ETES4SC
ETES4HC
ETES8MC
ETES8PC
ETES8SC
ETES8HC
ETES1HC-L
ETES2HC-L
ETES4HC-L
ETES8HC-L

ETES1MD
ETES1PD
ETES1SD
ETES1HD
ETES2MD
ETES2PD
ETES2SD
ETES2HD
ETES4MD
ETES4PD
ETES4SD
ETES4HD
ETES8MD
ETES8PD
ETES8SD
ETES8HD
ETES1HD-L
ETES2HD-L
ETES4HD-L
ETES8HD-L

ETERNUS DX60 S2, DX80 S2, DX90 S2


(7) Options
- Drive enclosure (2.5inch)
ETERNUS DX80 S2, DX90 S2

Dual-IOM type supports dual controller model only.

Drive enclosure for DX80 S2/DX90 S2 (2.5inch, dual-IOM type)


[Factory] ETEAD2CU
[Field] ETEAD2CU-L
- Rack mount type (2U)
- Enclosure [IOM (SAS 1port) x2, PSU x2] x1
- Up to 24 disk drives can be installed in one drive enclosure.
- Attachment list
Attachment
Notes
Qty
Rackmount kit
1 set
AC200V power cable
2
4m (NEMA L6-15P)
SAS cable
2
75cm: Bace unit <=>
Drive enclosure connection
Disk drive
Refer "Disk drive option (2.5inch)"
* Up to 24 disk drives can be installed.

Drive enclosure for DX80 S2/DX90 S2 (2.5inch, single-IOM type)


[Factory] ETEAD1CU
[Field] ETEAD1CU-L
- Rack mount type (2U)
- Enclosure [IOM (SAS 1port) x1, PSU x2] x1
- Up to 24 disk drives can be installed in one drive enclosure.
- Attachment list
Attachment
Notes
Qty
Rackmount kit
1 set
AC200V power cable
2
4m (NEMA L6-15P)
SAS cable
1
75cm: Bace unit <=>
Drive enclosure connection
Additional IOM for DX80 S2/DX90 S2
[Field] ETEAMA-L
- Attachment list
Attachment
Qty
IOM
1
SAS cable
1

Disk drive
Refer "Disk drive option (2.5inch)"
* Up to 24 disk drives can be installed.

33

Notes
75cm: Bace unit <=>
Drive enclosure connection

ETERNUS DX60 S2, DX80 S2, DX90 S2


(7) Options
- Drive enclosure (3.5inch)
ETERNUS DX80 S2, DX90 S2

Dual-IOM type supports dual controller model only.

Drive enclosure for DX80 S2/DX90 S2 (3.5inch, dual-IOM type)


[Factory] ETEAD2DU
[Field] ETEAD2DU-L
- Rack mount type (2U)
- Enclosure [IOM (SAS 1port) x2, PSU x2] x1
- Up to 12 disk drives can be installed in one drive enclosure.
- Attachment list
Attachment
Notes
Qty
Rackmount kit
1 set
AC200V power cable
2
4m (NEMA L6-15P)
SAS cable
2
75cm: Bace unit <=> Drive enclosure connection
Disk drive
Refer "Disk drive option (3.5inch)"
* Up to 12 disk drives can be installed.

Drive enclosure for DX80 S2/DX90 S2 (3.5inch, single-IOM type)


[Factory] ETEAD1DU
[Field] ETEAD1DU-L
- Rack mount type (2U)
- Enclosure [IOM (SAS 1port) x1, PSU x2] x1
- Up to 12 disk drives can be installed in one drive enclosure.
- Attachment list
Attachment
Notes
Qty
Rackmount kit
1 set
AC200V power cable
2
4m (NEMA L6-15P)
SAS cable
2
75cm: Bace unit <=> Drive enclosure connection
Additional IOM for DX80 S2/DX90 S2
[Field] ETEAMA-L
- Attachment list
Attachment
Qty
Rackmount kit
1 set
SAS cable
2

Notes
75cm: Bace unit <=> Drive enclosure connection

Disk drive
Refer "Disk drive option (3.5inch)"
* Up to 12 disk drives can be installed.

- Extension cable
ETERNUS DX80 S2, DX90 S2
- The Extension cable (3m) kit option can be ordered if the SAS cables (75cm)
supplied with the drive enclosures are too short to connect.
Extension cable between enclosures for DX80 S2/DX90 S2 (3m)
[Field] ETEC1Q3-L
- QSFP cable (3m) x1
Extension cable between enclosures for DX80 S2/DX90 S2 (6m)
[Field] ETEC1Q6-L
34
- QSFP cable (6m) x1

ETERNUS DX60 S2, DX80 S2, DX90 S2


(7) Options
- Thin Provisioning Feature
ETERNUS DX80 S2

Single controller model does not support Thin Provisioning Feature.

Thin Provisioning Feature License for DX80 S2


[Factory] ETEL8T
[Field] ETEL8T-L
- License label x1
- To use Thin provisioning Feature, one license is required per one unit.

ETERNUS DX90 S2

Thin Provisioning Feature License for DX90 S2


[Factory] ETEL9T
[Field] ETEL9T-L
- License label x1
- To use Thin provisioning Feature, one license is required per one unit.

[Factory]: Factory mount option


[Field]: Field upgrade option

35

ETERNUS DX60 S2, DX80 S2, DX90 S2


(7) Options
- Outlet box
ETERNUS DX60 S2, DX80 S2, DX90
- Power distribution unit
Power distribution unit for DX60 S2/DX80 S2/DX90 S2
(AC200-240V, 1U Max 2 enclosures connection)
ETEP4BU-L
Rack mount type (1U), AC200V
There are up to two options for connecting a base unit and
drive enclosure.
(PDU for Base unit x2 or PDU for Drive enclosure x2 or
PDU for Base unit x1 + PDU for Drive enclosure x1)
- Power distribution unit (AC200V)1
- Input AC cable (NEMA L6-15P, 3m) x2
- Output AC cable (3m) x4, Rack mount kit x1

NEMA L6-15 outlet


Power distribution unit for DX60 S2/DX80 S2/DX90 S2
(AC200-240V, 2U, Max 6 enclosures connection)
ETEP12U-L
Rack mount type (1U), AC200V
Up to six base units or drive enclosures can be connected.
(Base unit x6,
Base unit x2 + Drive enclosure x4
Base unit x1 + Drive enclosure x5, etc.)
- Power distribution unit (AC200V)1
- Input AC cable (NEMA L6-20P, 4m) x2
- Output AC cable (3m) x12, Rackmount kit x1

NEMA L6-20 outlet


Power distribution unit for DX60 S2/DX80 S2/DX90 S2
(AC200-240V, 2U, Max 8 enclosures connection)
ETEP16U-L
Rack mount type (1U), AC200V
Up to eight base units or drive enclosures can be connected.
(Base unit x8,
Base unit x2 + Drive enclosure x6
Base unit x1 + Drive enclosure x7, etc.)
- Power distribution unit (AC200V)1
- Input AC cable (NEMA L6-30P, 4m) x2
- Output AC cable (3m) x16, Rackmount kit x1

NEMA L6-30 outlet

36

ETERNUS DX60 S2, DX80 S2, DX90 S2


(7) Options

ETERNUS DX60 S2, DX80 S2, DX90


- IEC Power cable
AC cable (IEC60320 C13 - IEC60320 C14)
ST-PWG13
- To connect IEC 320-C14 components,
one option is required per one base unit or drive enclosure.
- AC200V cable (IEC320 C14, 3m) x2
200V (Standard)
IEC320

NEMA L6-15 outlet

IEC320 outlet

37

ETERNUS DX60 S2, DX80 S2, DX90 S2


(7) Options
ETERNUS DX60 S2, DX80 S2, DX90

Power Synchronized Unit


ST-PSM20U
- Power Synchronized Unit x1
- RS232C cable x2
- Parts kit for 19-inch rack
AC Sensor Unit (AC200V)
ST-PSL20SU
- AC Sensor Unit x1
- RCI cable (4m) x1
- RCI brunch connector x1
- Parts kit for 19-inch rack
Note that power cords (for AC power input) for power synchronized units and power cords (for AC sensor) to connect
server UPS units to power synchronized units or AC sensor units are not supplied with power synchronized units.
The IEC 60320-C14 port type is used for the AC IN ports and the SENSOR ports of the power synchronized units.
This port type is also used for the AC IN ports of the AC sensor units.
Check the specifications of the power sockets and server UPS unit outlets that are to be used for the power
synchronized units and AC sensor units. Prepare the required number of appropriate power cords.
Power cord (for AC power input)
- Each Power Synchronized Unit requires one Power cord.
- The voltage for the AC IN port is 10A 250V or less.
Power cord (for AC sensor)
- Each server UPS Unit that is to be connected to The Power Synchronized Unit requires one Power cord.
- Each AC sensor Unit requires one Power cord.
Be sure that the power cords have the approval of the appropriate safety agencies of the country where the equipment
will be used.

38

ETERNUS DX60 S2, DX80 S2, DX90 S2


(8) Cables
- Fibre channel cable (Fibre channel, 10Gbits/s iSCSI, FCoE connection)
ETERNUS DX60 S2
ETERNUS DX80 S2
ETERNUS DX90 S2

Fibre channel cable


Product ID
Length
CBL-MLLC05
5m
CBL-MLLC10
10m
CBL-MLLC20
20m
CBL-MLLC30
30m
With cover
CBL-MLLC40
40m
CBL-MLLC50
50m
CBL-MLLD1A
100m
CBL-MLLB02 *
2m
CBL-MLLB05 *
5m
Without cover
CBL-MLLB15 *
15m
* For connection between same rack.
Fibre channel card, Fibre channel switch

Notes
LC-LC

- SAS cable (SAS connection)


ETERNUS DX60 S2
ETERNUS DX80 S2
ETERNUS DX90 S2

SAS cable
Product ID
CBL-SASB1U
CBL-SASB3U
CBL-SASB6U

Length
1.5m - SAS connection
3m
6m

Notes

SAS card

- Twinax Cable (10 Gbit/s iSCSI withtout SFP+, FCoE without SFP+ connection)
ETERNUS DX80 S2
ETERNUS DX90 S2

Twinax cable
Product ID
Type
EBRTWX11
1m
EBRTWX31
3m
EBRTWX51
5m
S26361-F4571-L107
7m
S26361-F4571-L110
10m
S26361-F3989-L105
5m

Notes
Brocade/10G-SFPP-TWX-0101
Brocade/10G-SFPP-TWX-0301
Brocade/10G-SFPP-TWX-0501
Cisco/SFP-H10GB-ACU7M
Cisco/SFP-H10GB-ACU10M
Fujitsu/T26139-Y4006-M5

FCoE, iSCSI card

39

ETERNUS DX60 S2, DX80 S2, DX90 S2


(9) Rack
- Rack for ETERNUS DX60 S2, DX80 S2, DX90 S2
ETERNUS DX80 S2, DX90 S2 can be installed in the following racks.
Product name

Height

19-inch Rack Model 2742 Standard


19-inch Rack Model 2737 Standard
19-inch Rack Model 2724 Standard
19-inch Rack Model 2642 Slim
19-inch Rack Model 2624 Slim
19-inch Rack Model 2616 Slim
19-inch rack without stabilizers
19-inch rack with stabilizers

42U
37U
24U
42U
24U
16U
40U
40U

Product ID
Base Rack Expansion Rack
19R-274A2 19R-274B2
19R-273A2 19R-273B2
19R-272A2
19R-264A2 19R-264B2
19R-262A2
19R-261A2
ETNRKC2U ETNRKD2U
ETNRKC1U ETNRKD1U

- Notes
- Height and rack installation order are as follows.
Product name
Drive enclosure
ETERNUS DX80 S2 base unit
ETERNUS DX90 S2 base unit
Power distribution unit (AC200V)

Product ID
ETEAD2CU, ETEAD2CU-L
ETEAD2DU, ETEAD2DU-L
ET082DCU, ET082DDU
ET092DCU, ET092DDU
ETEP4BU-L
ETEP12U-L
ETEP16U-L

40

Height

Install order for the


rack
3

2U
2
1U
2U

ETERNUS DX60 S2, DX80 S2, DX90 S2


(10) ETERNUS Multipath Driver
OS
Windows
Solaris
Linux
AIX

Product ID
B025C1020H
B025C1120H
B025C1220H
B011103H0H
B0214G2H0H
B013162H0H

Product name
Windows ETERNUS Multipath Driver for Entry Model V2.x
Windows ETERNUS Multipath Driver for Standard Model V2.x
Windows ETERNUS Multipath Driver for Enterprise Model V2.x
Solaris ETERNUS Multipath Driver 3.x
ETERNUS Multipath Driver V2 (Linux 32bit/64bit)
AIX ETERNUS Multipath Driver 2

41