Glazed Elements - Fenestration Performance Requirements

Plot No.

1180973 AT NAIF

Project

BLDG(G+M+1)

Consultant

Glazed Elements - Fenestration Performance Requirements as


per Green Building Regulations & Specifications

1-3-2014 v1

Thermal
Transmittance -U

T M 90

W/m2 K
(1) If percentage of total area of external walls that let lights to
the external wall area is:

Glazed Elements - Fenestration Percentage

Orientation of Glazed Facades

Glazing Portion of a Roof Percentage to the Total 1-1 Equal or less than 40%
Roof Area
1-2 Between 40% - 60%

Wall Glazing Elements Percentage to the External


Wall Area

Thermal Bridges: for all new air conditioned buildings, Thermal


Shading Coefficient Light Transmittance Bridges, such as connection points between concrete or steel beams,
external walls and columns and around doors and windows, which
- SC
- LT
enable the flow of heat from outide into the building, must be
eliminated or insulated to reduce the amount of heat transfer.

2.10 (max)
1.90 (max)

0.40 (max)
0.32 (max)

0.25 (min)
0.10 (min)
0.10 (min)

Total Glass Area

220.58

m2

Total Glass Area

0.00

m2

1-3 Equal or greater than 60%

1.90 (max)

0.25 (max)

Total External wall Area

589.53

m2

Total Roof Area

479.59

m2

(2) For shopfronts and showrooms, other than those at ground


floor level:

1.90 (max)

0.76 (max)

3-1 Equal or less than 10%

1.90 (max)

0.32 (max)

0.40 (min)

3-2 Greater than 10%

1.90 (max)

0.25 (max)

0.30 (min)

37%

Perdominately North Orientation


Percentage Is:

(3) If percentage of glazing portion of a roof to the roof area is:

0%

65%

As Per Regulation (304.04)

Hide Empty Rows


Glazed Elements
Reference Name/No.
W1
W2
W3
W4A
W4B
AF1
AF2
AF3
AF4

No. of Windows on the Exposed Orientation


Height
m
1.52
2.43
1.60
4.42
3.86
2.39
2.44
2.44
2.44

Width

Item Area

m
1.52
1.82
1.20
3.45
3.45
3.23
2.44
0.71
1.83

m2
2.31
4.42
1.92
15.25
13.32
7.72
5.95
1.73
4.47
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00

Total Glazed Area at the Corresponding Orintation (m 2):

Wall

Height
m
4.22
4.17
3.30

Width
m
64.16
54.35
27.92

Width
m

Total Area

Reference Name/No.

Length
m

ROOF

21.42

22.39

479.59

Reference Name/No.
GROUND FLOOR
TYPICAL FLOOR
ROOF FLOOR

No.
1.00
1.00
1.00

Perdominately North Orientation


NW

N
7.00
3.00

NE

SE
E
9.00

SW

29.44

Total Area

m2
270.76
226.64
92.14

0.00

114.73

No. of Glass Layers

Thermal
Transmittance - U

2.00
2.00
2.00
2.00
2.00
2.00
2.00
2.00
2.00

W/m2 K
2.10
2.10
2.10
2.10
2.10
2.10
2.10
2.10
2.10

Horizontal

6.00

9.00

3.00
1.00
1.00
3.00
3.00
3.00
3.00

0.00

3.00
3.00
3.00

0.00

13.86

0.00

62.55

m2
0.00
0.00

Type of Roof

0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25

Color

Type

Note

M
M
M
M
M
M
M
M
M

GLAZING
GLAZING
GLAZING
GLAZING
GLAZING
GLAZING
GLAZING
GLAZING
GLAZING

THERMAL BREAK
THERMAL BREAK
THERMAL BREAK
THERMAL BREAK
THERMAL BREAK
THERMAL BREAK
THERMAL BREAK
THERMAL BREAK
THERMAL BREAK

Consultant Comments:

Light Reflective Value


LRV (%)
45.00
45.00
45.00

Light Colors on the Outside of Buildings: For all new buildings, at least 75% of the area of
externally painted walls must have a minimum Light Reflective (LRV) Value of 45%

Roof Solar Reflective


Index - SRI

Urban Heat Island Effect: All opaque external roofing surfaces must comply with a minimum Roof
Solar Reflective Index (SRI) Value according to table below for a minimum of 75% of the roof
area:

Flat & or Low


Steep
Steep Sloped
Sloped

0.40
0.40
0.40
0.40
0.40
0.40
0.40
0.40
0.40

0.00

0.00

Roof

Shading Coefficient Light Transmittance


- SC
- LT

78.00

Enter SRI Value

Type of Roof

Enter SRI Value

Steep Sloped Roofs (slopes steeper than 1:6)

29.00

Flat and Low Sloped Roofs

Min. Roof SRI


78.00