Professional Documents
Culture Documents
Multi-service Packet-based
Platform Product Description
V3.00.10
Date
2014/3/1
Author
BN
Reviewer
Notes
Not open to the third party
TABLE OF CONTENTS
Overview ............................................................................................................ 6
2
2.1
2.2
2.3
2.4
2.5
3
3.1
3.1.1
3.1.2
3.1.3
3.1.4
3.1.5
3.2
3.2.1
3.2.2
3.3
3.3.1
3.3.2
3.3.3
3.3.4
3.3.5
3.3.6
3.3.7
3.4
3.4.1
3.4.2
3.5
3.5.1
3.5.2
3.5.3
3.5.4
3.5.5
3.5.6
3.5.7
3.5.8
Functionality ...................................................................................................... 9
Link Characteristics.............................................................................................. 9
Ethernet ............................................................................................................... 9
POS ................................................................................................................... 10
CPOS ................................................................................................................ 11
E1/CE1 .............................................................................................................. 11
Frame Relay ...................................................................................................... 12
Routing Protocols............................................................................................... 12
Unicast Routing Protocols .................................................................................. 12
Multicast Routing Protocols ................................................................................ 15
MPLS and Traffic Engineering ........................................................................... 16
MPLS Overview ................................................................................................. 16
MPLS L3 VPN .................................................................................................... 17
MPLS L2 VPN .................................................................................................... 18
TDM Emulation .................................................................................................. 19
L2/L3 VPN Bridge .............................................................................................. 20
Multicast VPN .................................................................................................... 20
Traffic Engineering ............................................................................................. 20
IP VPN ............................................................................................................... 21
GRE ................................................................................................................... 21
IPSec ................................................................................................................. 21
Network Availability ............................................................................................ 22
Graceful Restart ................................................................................................. 22
NSR ................................................................................................................... 23
VRRP................................................................................................................. 23
FRR ................................................................................................................... 24
BFD ................................................................................................................... 25
MPLS OAM ........................................................................................................ 25
Ethernet OAM .................................................................................................... 26
OAM Mapping and Interworking ......................................................................... 26
3.6
3.6.1
3.6.2
3.6.3
3.6.4
3.6.5
3.6.6
3.6.7
3.7
3.7.1
3.7.2
3.7.3
3.7.4
3.7.5
3.8
3.8.1
3.8.2
3.8.3
3.8.4
3.9
3.9.1
3.9.2
3.9.3
3.9.4
3.9.5
3.9.6
QoS ................................................................................................................... 26
Packet classification and marking ...................................................................... 26
Traffic supervision and shaping.......................................................................... 27
Queue ................................................................................................................ 27
Congestion Management ................................................................................... 27
H-QoS................................................................................................................ 28
QPPB................................................................................................................. 28
Priority Inheritance ............................................................................................. 28
Security Features ............................................................................................... 29
Control Plane Security ....................................................................................... 29
Authentication and Authorization ........................................................................ 29
Unicast Reverse Path Forwarding ...................................................................... 30
Port Mirroring ..................................................................................................... 31
Netflow............................................................................................................... 31
Clock Synchronization ....................................................................................... 31
System Clock ..................................................................................................... 31
NTP ................................................................................................................... 32
Synchronous Ethernet ....................................................................................... 32
IEEE 1588v2 ...................................................................................................... 32
OPERATION AND MAINTENANCE................................................................... 34
NetNumen Unified Network Management Platform ............................................ 34
SNMP ................................................................................................................ 36
Connection Management ................................................................................... 37
LLDP.................................................................................................................. 37
Policing and Maintenance .................................................................................. 37
Diagnosis and Scheduling.................................................................................. 39
4
4.1
4.1.1
4.1.2
4.1.3
4.1.4
4.1.5
4.1.6
4.2
4.2.1
4.2.2
4.2.3
4.3
System Architecture........................................................................................ 40
Product layout .................................................................................................... 40
Layout of ZXCTN 9000-18E ............................................................................... 41
Layout of ZXCTN 9000-8E ................................................................................. 43
Layout of ZXCTN 9000-5E ................................................................................. 44
Layout of ZXCTN 9000-3E ................................................................................. 47
Layout of ZXCTN 9000-2E10 ............................................................................. 50
Layout of ZXCTN 9000-2E4 ............................................................................... 51
System Hardware Architecture........................................................................... 52
System Hardware Architecture Overview ........................................................... 52
The Working Philosophy of Hardware System ................................................... 54
Introduction to Hardware Module ....................................................................... 55
Software Architecture ......................................................................................... 58
5
5.1
5.2
5.2.1
5.2.2
5.2.3
6
6.1
6.2
FIGURES
Figure 1-1 ZXCTN 9000-18E/-8E/-5E/-3E/-2E10/-2E4 ........................................................ 6
Figure 4-1 The appearance of ZXCTN 9000-18E...............................................................41
Figure 4-2 The architecture layout of ZXCTN 9000-18E ....................................................42
Figure 4-3 The appearance of ZXCTN 9000-8E.................................................................43
Figure 4-4 The architecture layout of ZXCTN 9000-8E ......................................................44
Figure 4-5 The appearance of ZXCTN 9000-5E AC ...........................................................45
Figure 4-6 The appearance of ZXCTN 9000-5E DC...........................................................45
Figure 4-7 The architecture layout of ZXCTN 9000-5E AC.................................................46
Figure 4-8 The architecture layout of ZXCTN 9000-5E DC ................................................46
Figure 4-9 The appearance of ZXCTN 9000-3E AC ...........................................................47
Figure 4-10 The appearance of ZXCTN 9000-3E DC.........................................................48
Figure 4-11 The architecture layout of ZXCTN 9000-3E AC...............................................49
Figure 4-12 The architecture layout of ZXCTN 9000-3E DC ..............................................49
Figure 4-13 The appearance of ZXCTN 9000-2E10 ...........................................................50
Figure 4-14 The architecture layout of ZXCTN 9000-2E10.................................................50
Figure 4-15 The appearance of ZXCTN 9000-2E4 .............................................................51
Figure 4-16 The architecture layout of ZXCTN 9000-2E4 ..................................................51
Figure 4-17 ZXCTN 9000-E Hardware Architecture ...........................................................53
Figure 4-18 The Software System Architecture ..................................................................58
Figure 6-1 IPRAN network .................................................................................................68
Figure 6-2 FMC network ....................................................................................................68
TABLES
Table 5-1 9000-18E/8E/5E/3E Physical Indices....................................................................61
Table 5-2 9000-2E10/2E4 Physical Indices ..........................................................................62
Overview
ZXCTN 9000 series are new-generation Carrier class Multi-service Packet-based
Platform (CMPP) promoted by ZTE to keep with the development trend of IP
telecommunication services. With packet as kernel, they implement multi-service bearing
and provide customers with Mobile Backhaul, Metro-E, IP-RAN and FMC end-to-end
solution. They help customers to reduce network building cost and maintenance cost,
and assist carriers to realize smooth network evolvement.
ZXCTN 9000 series devices consist of two sub-sequences, which have nine models:
ZXCTN 9000-E series are introduced in this paper, which are shown as follows:
Figure 1-1
ZXCTN 9000-18E/-8E/-5E/-3E/-2E10/-2E4
Highlight Features
2.1
Multi-Service Integration
Unified service platform: Integrating business private line service, WLAN, OLT,
2G/3G/LTE, saving equipment room and reduces users investment, realizing fast
service deployment and network reconfiguration, and helping the operators to build
refined network.
2.2
Wide-Bandwidth Access
With advanced system architecture, distributed and modular design philosophy, ZXCTN
9000 series have largest switch fabric capacity and highest performance packet
processor in industry to provide best performance and flexibility. 9000 series can
construct network platform facing future.
Providing 400Gbps high-speed forwarding capability for each slot to cater the needs
of network bandwidth increase
Adopting
high-performance
network
processor,
TCAM
(Ternary
Supporting large capacity of RIB/FIB to cater the needs of large scale network
deployment.
2.3
Supporting multi-link binding and load sharing. Supporting LDP FRR, IP FRR, TE
FRR, VPN FRR, TE Hot standby, static TE protection group, IGP FC and VRRP
technology to protect node, link and end to end line level failure to guarantee
network stability.
Supporting fast failure detecting BFD for everything to implement failure recovery
and binding BFD with various route protocols, VRRP, LDP and RSVP. Supporting
IGP FRR/LDP FRR/IP FRR/RSVP TE FRR and satisfying carrier-class protection
requirements for key services.
Supporting MPLS OAM and Ethernet OAM, various granularity and hierarchy,
provide refined management of fault, performance and service.
2.4
IPv6 Evolution
Based on the requirement of IPv6 evolution, ZXCTN 9000 supports:
Supporting 4in6 tunnel, 6to4 tunnel, 6over4 tunnel, 6PE and 6vPE to cater the
needs of IPv6 services.
According to the high performance service cards, provide NAT444, DS-Lite, 6rd and
NAT64&DNS64.
2.5
Providing complete and easy VPN service management system, graphical service
wizard, simple fool configuration, featured large customer self-management,
which brings great convenience for users VPN service development.
and
deployment
during
implementation,
and
QoS
policy
Functionality
3.1
Link Characteristics
3.1.1
Ethernet
ZXCTN 9000-E Ethernet links support the following basic features:
Supporting loopback
3.1.2
POS
Packet Over SONET (POS) is a high speed, advanced WAN connection technology. It
uses
high
speed
transmission
channel
provided
by
Synchronous
Optical
10
3.1.3
Supporting BCP
Supporting multilink
CPOS
The Channelized POS (CPOS) interface can precisely divide the bandwidth by fully
utilizing the SDH features,
3.1.4
E1/CE1
Time-division multiplexing (TDM) is a type of digital (or rarely analog) multiplexing in
which two or more bit streams or signals are transferred appearing simultaneously as
sub-channels in one communication channel, but are physically taking turns on the
channel.
11
3.1.5
Frame Relay
Frame Relay (FR) is a high-performance WAN protocol. It runs on both the physical layer
and the data link layer of the Open System Interconnection (OSI) reference module. The
FR only implements the functions of the physical layer and the data link layer of the OSI
reference module. The traffic control and error correction functions are implemented by
intelligent terminals. Using this method, the processing duration of the devices is reduces,
the network throughput is increased, and the communication delay is reduced.
Supporting DLCI
Supporting FR PVC
3.2
Routing Protocols
3.2.1
Supporting IPv4 dynamic routing protocol: BGP4, OSPF, IS-IS and RIP.
12
Basic and enhanced BGP protocol functions, including route damping, route
reflector, confederation, and extended community, etc;
MP-BGP;
VPN access;
BGP FRR.
OSPF routing protocol exchanges routing information among all the routers within
one AS. It is an interior gateway protocol (IGP) based upon link status. OSPF
creates link status database by announcing network interface status among routers,
and generates the shortest path tree. Then each OSPF router uses these shortest
paths to create routing table.
OSPF routing protocol supports the following functions:
NSSA;
OSPF-TE;
OSPF FRR.
13
IS-IS-TE;
IS-IS FRR.
RIP protocol is a dynamic routing protocol running on UDP protocol module. As the
earliest and simplest routing protocol promoted by IPv4 network, it is implemented
based upon distance vector algorithm of local network. RIP broadcasts route by
sending routing information (routing table). In every 30 seconds, it broadcasts
routing table, and maintains neighbor status. At the same time, it calculates its own
routing table as per the received routing information. As RIP runs easily, it is
suitable for small-size network.
RIP routing protocol supports the following functions:
14
3.2.2
Supporting IPv4 client multicast routing protocols, IGMPv1, IGMPv2 and IGMPv3.
Supporting PIM-SSM. When multicast source has not been confirmed, it can
directly join in multicast source without registering to Rendezvous Point (RP).
15
Supporting Anycast RP. Multiple RPs exists in a multicast domain. MSDP peers are
set among RPs. Multicast source can choose the nearest RP for registration;
receiver can add the nearest RP to its sharing tree. Hence, RP load sharing can be
implemented. When one RP is invalid, another nearest RP will substitute it to realize
RP redundant backup;
3.3
3.3.1
16
3.3.2
Supporting ordered label control mode and independent label control mode
Supporting mLDP
MPLS L3 VPN
MPLS L3 VPN is a kind of IP VPN based on MPLS technology. It is also called L3VPN,
which applies MPLS technology to routers and switches. MPLS VPN simplifies the route
selection mode of core routers, and it realizes IP virtual private network by means of the
label switching of conventional routing technology.
MPLS VPN can be used to construct broadband Intranet and Extranet, which can satisfy
the requirements of many services cleverly. MPLS VPN can utilize the powerful
17
Work as P, PE or CE.
Supporting dynamic (BGP, RIP, OSPF, and IS-IS) and static (static route) VPN
access.
3.3.3
Supporting HoVPN
MPLS L2 VPN
There are several types of MPLS based L2 VPN services: VPWS (Virtual Private Wire
Service), VPLS (Virtual Private LAN Service), MS-PW (Multi-Segmented PW) and VLSS
(Virtual Local Switch Service).
18
Supporting H-VPLS;
3.3.4
Supporting MS-PW;
Supporting MC-ELAM
TDM Emulation
TDMoE refers to circuit emulation on Ethernet which realizes the delivery of TDM service.
With the help of a tunnel built on the Ethernet, TDM traffic slots which is changed into
packets are transparently transferred via PW built by PWE3 (Pseudo Wire Emulation
Edge-to-Edge) technology to the destination. The traffic packets will be resumed to the
original TDM traffic after it arrives at the destination. TDM equipment at both ends of the
network does not care about its connecting networks.
TDM over Ethernet and MPLS network are a kind of transparent transmission to TDM
service, so it is well compatible with traditional telecomm network. In other words, all the
traditional protocols, signaling, data , voice and video service can use this new
technology; in addition, without changing any existing network, carriers can make full use
of the existing resource to implement tradition TDM service on Ethernet or MPLS
network.
19
3.3.5
3.3.6
Multicast VPN
Multicast VPN is a technology that supports multicast services on the base of BGP/MPLS
IP VPN. This technology accomplishes the multicast data transport between private
networks by encapsulating private network multicast packets and transmitting them on
the multicast tunnels established between sites.
3.3.7
Traffic Engineering
Network congestion is a main problem influencing backbone network performance. The
reason of local congestion may be inadequate network resource or unbalanced network
resource load. TE (Traffic Engineering) resolves congestion caused by unbalanced load.
MPLS TE is a technology combining TE and MPLS. By MPLS TE, service provider can
accurately control the path traffic goes through so as to avoid the nodes with congestion
and solve the problem of part of path being overloaded while the other part of path being
idle; so that fully utilize the current bandwidth resource. Meanwhile, MPLS TE can
reserve resource during the process of LSP tunnel establishment in order to ensure QoS.
MPLS TE use CSPF (Constrained Shortest Path First) algorithm to calculate the shortest
path to certain node.
ZXCTN 9000-E supports MPLS TE technology providing the following features:
20
RSVP
DS-TE functions including uni-CT and multi-CT DS-TE tunnel; and MAM, RDM
bandwidth models.
RSVP-TE MIB
3.4
IP VPN
3.4.1
GRE
GRE is a widely used technology that encapsulates PDUs of a network layer protocol in
PDUs of any other network layer protocol. It is usually used to establish a GRE tunnel to
pass through different Layer 3 networks. GRE supports to encapsulate messages of a
protocol in messages of another protocol and transmit the messages on networks. It can
encapsulate the packets of some network layer protocols (such as IP and IPX), so that
the encapsulated packets can be transmitted through another network layer protocol
(such as IP).
3.4.2
IPSec
Internet Protocol Security (IPSec) is a protocol suite for securing Internet Protocol (IP)
communications by authenticating and encrypting each IP packet of a communication
21
session. IPSec includes protocols for establishing mutual authentication between agents
at the beginning of the session and negotiation of cryptographic keys to be used during
the session. IPSec can be used in protecting data flows between a pair of hosts
(host-to-host), between a pair of security gateways (network-to-network), or between a
security gateway and a host (network-to-host).
3.5
Network Availability
3.5.1
Graceful Restart
Graceful Restart (GR) is a mechanism aiming at minimizing the impact of routing protocol
restart. It tries to reduce route jitter caused by router restart as much as possible and
diminish the influence of routing protocol restart. When routing protocol restarts, the
restarting router implements its routing information synchronization with the neighbor
router as soon as possible. Then it updates local routing information without redoing
controlling layer. The routing protocols with GR capability are as follows. Although each
protocol implements uniquely, they have similar basic principle.
GR supported by ZXCTN 9000-E includes:
22
BGP GR
IGP GR
LDP GR
RSVP GR
3.5.2
PIM GR
L3/L2 VPN GR
NSR
NSR (Nonstop routing) ensures that the route between the forwarding plane and the
control plane is not interrupted after the switchover between the active/standby control
planes. With this function, the device faults almost have no influence on the whole
network.
The device with the NSR function synchronizes the information in real time between the
processing units of the active/standby control planes, which ensures that the statuses
and processing logics of the processing units of the active/standby control planes are the
same. When the processing unit of the active control plane is faulty, the active/standby
switchover happens. The processing unit of the standby control plane immediately
becomes active. In this case, the services of both the forwarding plane and the control
plane are not interrupted, and extra protocol recovery procedures with its neighbors are
not required.
3.5.3
OSPF NSR
ISIS NSR
BGP NSR
LDP NSR
RSVP NSR
BFD NSR
PIM NSR
VRRP
VRRP protocol implements gateway backup function in the multiple-access LAN (such
as Ethernet) by providing a set of checking and election mechanism. VRRP maintains
uninterruptible service of network system for accessed host equipment by backup of
23
gateway equipment in LAN. That is to say, VRRP backups route next-hop equipment of
accessed host equipment.
VRRP protocols supported by ZXCTN 9000-E have the following features:
3.5.4
FRR
FRR make secondary path before break. So router who detects link or node fault can
switch traffic to backup path immediately.
24
Supporting IP FRR
Supporting TE hot-standby
Supporting DNI-PW
3.5.5
BFD
One important performance of network equipment is to quickly detect the fault between
adjacent systems, and to create other path as soon as possible. BFD (Bidirectional
Forwarding Detection) just perfectly fulfill this aim. The main function of BFD is to provide
a light-loaded fast failure detection mechanism for neighboring forwarding engine.
Millisecond-level link detection and route switching function can be realized by combining
BFD and FRR.
BFD supported by ZXCTN 9000-E has the following features:
3.5.6
MPLS OAM
MPLS Operation, Administration and Maintenance (OAM) technology provides a set of
mechanisms for failure detection on MPLS network.
Supporting VCCV
25
3.5.7
Ethernet OAM
Ethernet OAM helps to install, monitor and troubleshoot Ethernet network.
3.5.8
3.6
QoS
3.6.1
26
can be the criteria for the next classification, and the mark also can be carried to other
devices by the packet.
3.6.2
3.6.3
Supporting srTCM
Supporting trTCM
Supporting GTS
Queue
Basic queue scheduling algorithms supported by ZXCTN 9000-E include:
3.6.4
PQPriority Queue
Congestion Management
Random Early Detection (RED) can be adopted as an avoiding mechanism preventing
congestion problem at bandwidth bottleneck. WRED (Weighted Random Early Detection)
combines IP priority level determined by weighted calculation and RED algorithm. WRED
provides a statistics tool to maintain effective link utilization.
Congestion management algorithms that ZXCTN 9000-E supports are:
27
3.6.5
H-QoS
Hierarchical QoS specifies QoS behavior at multiple policy levels, which provides a high
degree of granularity in traffic management.
3.6.6
QPPB
QoS Policy Propagation through the Border Gateway Protocol (QPPB) technology is a
QoS technology deployed through Border Gateway Protocol (BGP) routing policies. On
the base of BGP routes (such as community, AS paths list, and prefix list), QPPB
classifies routes and applies different QoS policies for different classes.
With QPPB technology, routes can be classified in advance by setting BGP routes on
BGP route senders. This simplifies route modification on route receivers.
3.6.7
Priority Inheritance
Priority inheritance is used to accomplish priority inheritance among different types of
packets (including common IP packets, VLAN packets and MPLS packets), that is, the
conversion among IP-Precedence, VLAN-802.1p, and MPLS-EXP.
28
3.7
Security Features
3.7.1
3.7.2
Local authentication
ZXCTN 9000-E implements complete protocol security authentication for protocols such
as SSH, PPP, routing protocols and SNMP based on different requirements of protocol
security authentication.
29
RIP v2, OSPF, IS-IS, and BGP support MD5-based cipher text authentication.
3.7.3
30
3.7.4
Port Mirroring
With the port mirroring function, partial or all traffic of the source ports can be copied to a
specified mirroring port or a destination port. When the normal throughput of the source
ports is not affected seriously, the mirroring port is used to monitor the traffic of the
network.
3.7.5
Netflow
ZXCTN 9000-E supports netflow, which is a kind of technology based on sampling and
designed to monitor the network. Main features of netflow are:
3.8
Clock Synchronization
3.8.1
System Clock
Clock synchronization module serves to precisely transmit synchronization timing signals
from a reference clock to each clock node in a communication network. In this way,
clocks at various nodes are adjusted to maintain clock synchronization, so as to meet the
31
Supporting synchronization from BITS, POS, Ethernet, GPS, 1PPS+TOD and IEEE
1588
3.8.2
NTP
Network Time Protocol (NTP) is a time synchronization protocol applied to different
network members. The NTP devices synchronize their clock by exchanging NTP packets,
thus to keep their clocks consistent.
3.8.3
Synchronous Ethernet
ZXCTN 9000-E supports synchronous Ethernet technology.
To generate high-precision system clock, Synchronous Ethernet adopts an external
high-precision clock (2MBits, 2MHz) for reference, and the generated system clock is
distributed to all line cards. Furthermore, GPS can be used for clock reference.
3.8.4
IEEE 1588v2
ZXCTN 9000-E supports IEEE 1588v2 protocol. 1588v2 protocol provides a set of
precise time synchronization program -PTP (Precision Time Protocol), which supports
time and frequency synchronization, providing sub-microsecond time synchronization
accuracy. In 1588v2 protocol, PTP packets can have a variety of packages, such as UDP
32
(IPV4, IPV6), Ethernet and so on. At the same time, PTP packets can be transmitted by
multicast mode or unicast mode.
To the communication, clock can be divided into the master clock and the slave clock. In
theory, any clock can serve as the master clock and slave clock, but a PTP
communication subnet can have only one master clock. Optimal clock throughout the
system clock is the GMC (Grandmaster Clock), which is the best stability, accuracy,
reliability and so on. According to the precision and level of the clock on each node, and
traceability of UTC (Universal Time Clock), the best master clock algorithm automatically
selects the subnet master clock; in only one subnet system, the master clock is the GMC.
Each system has only one GMC, and each subnet has only one master clock, slave clock
should keep pace with the master clock.
Supporting BMC
33
3.9
3.9.1
34
get timely service quality report and give prompt evaluations and adjustment on
entire network resource configuration.
35
3.9.2
SNMP
Administrators use SNMP as a main way to operate, control and maintain the router. In
order to perform network management, users use NMS software to send and receive
SNMP packets between the managed network elements and the management station.
36
3.9.3
Connection Management
ZXCTN 9000-E series equipment provides multiple equipment login and management
configuration modes, which enables user to choose the optimal way to configuring its
connections. It makes the equipment maintenance easier.
3.9.4
LLDP
Link Layer Discovery Protocol (LLDP) is a protocol defined by IEEE 802.1AB. Network
management systems can know the topology and changes of L2 networks through LLDP.
LLDP organizes local device information into Type/Length/Value (TLV) and encapsulates
it in a Link Layer Discovery Protocol Data Unit (LLDPDU) to send it to the
direct-connected neighbor. At the same time, LLDP saves the LLDPPDU sent by
neighbors in the standard MIB, so that network management systems can query and
determine the communication states of links.
3.9.5
37
Equipment Policing:
There are indicators on power supply module, fan, MPU and all LICs. They show
the operating status of these components;
Fan monitoring is done by special fan module which can test the operation and
status. Besides, it is also capable of intelligent fan speed adjustment.
When the fan, power supply or temperature goes working, the voice awarding and
software warning will be generated;
The MPU switchover and hot swappable records are kept for reference;
The system monitors the operating status of the software, when abnormity happens,
the LIC will be restarted and MPU switchover will be implemented as well;
38
Via CLI, user can check the basic information of all MPU, LIC, and optical modules;
User can decide if console login require user name and password or not;
3.9.6
Supporting RMON
Supporting SYSLOG
Support the display of status of internal register of line card and memory
address
39
Ping and Trace Route: by inspecting if the network connection is reachable, the
transport path of the online record packet acts as the reference;
Debug: rich debug commands are provided to each of software. Every debug
command supports multiple debugging parameters, so it can be controlled flexibly.
Via debug command, specific information on the progress, message processing
and tolerance inspection of the service in the course of operation can be displayed;
Mirroring image service: it supports interface-based mirroring image, via which the
incoming, outgoing or bidirectional messages are replicated to the observed
interface.
System Architecture
4.1
Product layout
ZXCTN 9000 series product uses chassis-based architecture that is popular in the
industry. Adopting all-in-one chassis and modular architecture, ZXCTN 9000 can provide
flexible scalability.
The entire equipment is mainly composed by chassis, fan tray, air intake plane,
backplane, power supply module, management processor unit, switch fabric unit and
service line cards.
The chassis is made by sheet metal. It is an entire architecture composed by two-side
boards, soleplate, top plate, and structure tracks. The module insert and cabling can be
done in the front of chassis. The power supply module and fan tray are designed in
modular architecture. The entire device is 19 inch which totally goes in line with the
industry standard; as a result, it can be put in IEC 297 or ETSI standard racks.
40
4.1.1
Figure 4-1
5. Dust screen
6. Air inlet
3. Ant-dust Panel
7. Dust screen
41
Figure 4-2
LPC+LIC
PFU+PIU
LPC+LIC
PFU+PIU
PFU+PIU
LPC+LIC
PFU+PIU
LPC+LIC
MPU
MC
PFU+PIU
LPC+LIC
LPC+LIC
SFU
LPC+LIC
SFU
LPC+LIC
SFU
SFU
LPC+LIC
26
Air filter
Air inlet
PFU+PIU
SC
PFU+PIU
SC
PFU+PIU
SC
PFU+PIU
SC
PFU+PIU
SC
PFU+PIU
SC
PFU+PIU
SC
PFU+PIU
SC
18
19
20
21
22
23
24
25
Air inlet
Air filter
PFU+PIU
LPC+LIC
PFU+PIU
LPC+LIC
LPC+LIC
PFU+PIU
LPC+LIC
PFU+PIU
PFU+PIU
LPC+LIC
MPU
MC
PFU+PIU
LPC+LIC
LPC+LIC
PFU+PIU
10 11 12 13 14 15 16 17
LPC+LIC
PFU+PIU
PFU+PIU
LPC+LIC
27
The chassis of ZR10 9000-18E is 41U (1U=44.45mm) high and its entire size goes like
442mm*634mm*1819.6mm (W*D*H). With vertical slots, ZXCTN 9000-18E is designed
with 28 slots including 18 service line card slots, 2 MC (Main Control unit) and 8 SC
(switch unit). The MC is designed in 1:1 redundant backup and SC is in 6+2 redundant
backup.
The power supply module is designed to work in N+1 or N+N mode to enhance the
reliability of the entire power supply system. In N+1 DC mode, the system supports a
maximum of 12 (11+1) power supply modules. In N+N mode, the system supports a
maximum of 16 power supply modules (8+8).
The ZXCTN 9000-18E has 12 fan modules, including 10 for LPC boards and two for MC
boards. These modules are installed at the air outlet of the system, and dissipate heat by
air exhaust. The cool air enters the chassis from the middle lateral sides of the chassis
42
and passes by the boards, and then the fans blow the hot air out of the chassis from the
rear top, bottom, and left side of the chassis.
4.1.2
Figure 4-3
7. Air inlet
1. Air inlet
2. Fan module
3. Power Supply module
43
Figure 4-4
Cable bracket
LP PF CU + LIC
PIU
LP PF CU + LIC
PIU
LP PF CU + LIC
PIU
MS SF CU
1110
77
LP PF CU + LIC
PIU
LP PF CU + LIC
PIU
LP PF CU + LIC
PIU
10
LP PF CU + LIC
PIU
LP PF CU + LIC
PIU
MS SF CU
S CF
00
SC
FAN
Air inlets
The chassis of ZR10 9000-8E is 14U (1U=44.45mm) high and its entire size goes like
441mm*619.5mm*749.4mm (W*H*D). With vertical slots, ZXCTN 9000-8E is designed
with 12 slots including 8 service line card slots, 2 MSC (main switch & control unit) and 2
SC (switch fabric unit). The MC is designed in 1:1 redundant backup and SC is in 3+1
redundant backup.
The power supply module is designed in online backup mode. It is capable of providing
-48V DC modes. DC power supply mode is in 2+2 design to enhance the reliability of the
entire power supply system.
There are five groups of fans trays on the top-back part of the chassis respectively. So,
the air enters the device from the front bottom and lateral bottoms, and leaves the device
from the back top.
One set of cable brackets on the top part of the line card, which gives conveniences for
cabling.
4.1.3
44
Figure 4-5
1. Dust screen
2. Lateral air inlet
3. Fan module
4. Air outlet
Figure 4-6
45
1. Dust screen
2. Air inlet
3. Fan module
4. Power supply module
Figure 4-7
LPC+LIC
LPC+LIC
LPC+LIC
MSC
MSC
LPC+LIC
LPC+LIC
AC Power Supply
Figure 4-8
AC Power Supply
LPC+LIC
LPC+LIC
LPC+LIC
MSC
MSC
LPC+LIC
LPC+LIC
The chassis of ZXCTN 9000-5E AC is 8U (1U=44.45mm) high and its entire size goes
like 442mm*352.8mm*740mm (W*H*D). And the chassis of ZXCTN 9000-5E DC is 7U
high and its entire size goes like 442mm*308.3mm*740mm (W*H*D).
46
With horizontal slots, ZXCTN 9000-5E is designed with7 slots including 5 service line
cards and 2 MSCT. The MSC is designed in 1:1 redundant backup and Switch Fabric
Unit is in 1+1 redundant backup.
The power supply module is designed in hot backup mode. It is capable of providing -48V
DC or 110/220V AC modes. DC power supply mode is in 1+1 design, which enables 2
groups of -48V DC offer electricity at the same time. AC power supply mode uses 1+1
backup to enhance the reliability of the entire power supply system.
Air filter prevents dusts from falling down to the chassis. The air enters the device from
the right side, and the air leaves the device from the back.
Two sets of cable brackets on the both sides, which give conveniences for cabling.
4.1.4
Figure 4-9
47
1. Dust screen
2. Lateral air inlet
3. Fan module
4. Air outlet
Figure 4-10
1. Dust screen
2. Air inlet
3. Fan module
4. Power supply module
48
Figure 4-11
LPC+LIC
LPC+LIC
LPC+LIC
MC
AC Power Supply
Figure 4-12
AC Power Supply
LPC+LIC
LPC+LIC
LPC+LIC
MC
MC
MC
The chassis of ZXCTN 9000-3E AC is 5U (1U=44.45mm) high and its entire size goes
like 442mm*219.4mm*738mm (W*H*D). And the chassis of ZXCTN 9000-3E DC is 4U
high and its entire size goes like 442mm*175mm*738mm (W*H*D). With horizontal slots,
ZXCTN 9000-3E is designed with 5 slots including 3 service line cards and 2 MC. The
MC is designed in 1:1 redundant backup.
The power supply module is designed in hot backup mode. It is capable of providing -48V
DC or 110/220V AC modes. DC power supply mode is in 1+1 design, which enables 2
groups of -48V DC offer electricity at the same time. AC power supply mode uses 1+1
backup to enhance the reliability of the entire power supply system.
Air filter prevents dusts from falling down to the chassis. There are two groups of fans
trays on the back part of the chassis. The air enters the device from the right side, and
the air leaves the device from the back.
Two sets of cable brackets on the both sides, which give conveniences for cabling.
49
4.1.5
Figure 4-13
3. Cable tray
2. Handle
4. Board area
Figure 4-14
F
A
N
LIC
PFU+PIU
6
LIC
LIC
PFU+PIU
4
LIC
PFU+PIU
LPC
11
PFU+PIU
LPC
10
LIC
PFU+PIU
2
LIC
LIC
PFU+PIU
0
LIC
MC
PFU+PIU
8
MC
POWER1 PFU+PIU
POWER2
The chassis of ZR10 9000-2E10 is 5U (1U=44.45mm) high and its entire size goes like
219.4mm*442mm*220mm (H*W*D). With horizontal slots, ZXCTN 9000-2E10 is
designed with 12 slots including 2 service line card slots, 2 MC (Main Control unit) and 8
interface card slots. The MC is designed in 1:1 redundant backup.
ZXCTN 9000-2E10 supports 1+1 redundancy for power supply modules. The DC power
supply modules are installed on the front side of the chassis.
50
ZXCTN 9000-2E10 chassis has one fan module installed at the air outlet of the system,
which dissipates heat by air exhaust. The cool air enters the chassis from the right side of
the chassis and passes by the boards and power supply modules, and then the fans blow
the hot air out of the chassis from the left side of the chassis.
4.1.6
Figure 4-15
Figure 4-16
F
A
N
PFU+PIU
LPC
LIC
PFU+PIU
0
LIC
MC
PFU+PIU
2
MC
POWER1 PFU+PIU
POWER2
The chassis of ZR10 9000-2E4 is 3U (1U=44.45mm) high and its entire size goes like
130.5mm*442mm*220mm (H*W*D). With horizontal slots, ZXCTN 9000-2E4 is designed
with 6 slots including 2 service line card slots, 2 MC (Main Control unit) and 2 interface
card slots. The MC is designed in 1:1 redundant backup.
51
ZXCTN 9000-2E10 supports 1+1 redundancy for power supply modules. The DC power
supply modules are installed on the front side of the chassis.
ZXCTN 9000-2E4 chassis has one fan module installed at the air outlet of the system,
which dissipates heat by air exhaust. The cool air enters the chassis from the right side of
the chassis and passes by the boards and power supply modules, and then the fans blow
the hot air out of the chassis from the left side of the chassis.
4.2
4.2.1
52
Figure 4-17
Totally independent data forwarding platform, local control platform, remote control
plane enable isolated physical tunnels for delivering control plane message and
control plane configuration information. This method ensures the independent
operation of data plane and control platform.
Advanced switching fabric architecture via VOQ (Virtual Output Queue) technology
realizes multiple virtual output queues in one physical tunnel, which realizes
end-to-end traffic control and QoS in switching plane. It realizes real non-blocking
service.
Line Process Card (LPC) uses high-performance network processor, together with
traffic management chip and large-capacity TCAM to realize processing over
high-speed interface. The adequate flexible management hardware queue can
53
support multi-level HQOS scheduling, which matches precise users demands for
multi-service and QoS management.
LPC also supports local FLASH to save image file, which greatly shortens the
version download in the course of system initiation.
Line Interface Card (LIC) flexible subcard enables the PFU to support hybrid
interface cards with different speed and types. It gives conveniences to flexible
networking.
4.2.2
54
4.2.3
4.2.3.1
Management and maintenance of the whole router; ensuring that all line interface
boards function properly, so that IP packets can be successfully routed and
forwarded.
Providing the reset function for the MSCT (Switch Fabric Unit), LPC (Packet
Forwarding Unit), ESU (Ethernet Switch Unit), and interface boards of the router.
Providing the operation and management interface for the router system; router
maintenance, configuration and management are implemented at the interface.
Providing the 1588 clock function. (There are two kinds of MCT. One supports 1588;
the other one doesnt support 1588.)
The active and standby MCT communicate with each other via special internal
communication tunnel. A dedicated circuit on MCT monitors the operation status of CPU
in real time, so when serious fault like storage ECC verifying error and the breakdown of
Ethernet switching chip, the hardware will implement the switchover of main and standby
MPUs.
55
4.2.3.2
To ensure the reliability and redundancy of the switching system, ZXCTN 9000 uses
N+1 load sharing and redundant design, plus all SFUs working at the same time.
When 1 MSCT breaks down, the rest still can provide adequate switching capacity
for entire system switching process.
Monitoring and test bus independent from service has independent power supply,
providing the monitoring information on the power, voltage, current, temperature of
MSCT, the control of hot swappable module, reset and boot-up, etc.
4.2.3.3
Management and maintenance of the whole router; ensuring that all line interface
boards function properly, so that IP packets can be successfully routed and
forwarded.
56
Providing the reset function for the MSCT (Switch Fabric Unit), LPC (Packet
Forwarding Unit), ESU (Ethernet Switch Unit), and interface boards of the router.
Providing the operation and management interface for the router system; router
maintenance, configuration and management are implemented at the interface.
Providing the 1588 clock function. (There are two kinds of MCT. One supports 1588;
the other one doesnt support 1588.)
4.2.3.4
4.2.3.5
57
Working together with different service licenses, ZXCTN 9000 can offer services
like CGN (Carrier Grade NAT), Netflow, L2TP, and so on.
4.3
Multiple services can be loaded on the same service processing unit card.
Software Architecture
Based upon ZTEs self-researched route operation system ZXROSng, ZXCTN 9000-E
can be adaptive to all kinds of network in any high-performance and complicated
commercial environment. This software has the most integrated network features built
based upon international standard. The entire software architecture is as shown as
following:
Figure 4-18
IP Routing Subsystem
L2 Protocol Subsystem
Network Management
Subsystem
Multicast Routing
Protocol
Subsystem
SNMP Subsystem
Unicast Routing
Protocol Subsystem
Statistical Alarm
Subsystem
Support Protocol
Subsystem
The Security
Subsystem
MPLS Protocol
Subsystem
The Security
Subsystem
Hardware & Drive Subsystem: Provide drives for the software of MCT, line card,
backplane, fan and power supply module;
Distributed Operation System Support Platform: As the core of ZXCTN 9000 series
software system, it provides real-time operation system. Downstream, it is
responsible for the entire hardware system of the routing switch, and upstream it
offers a unified operating platform to the operating program of the entire software
system. It features high reliability, real-time service, self-healing, maintainability,
and encapsulation;
58
Unicast Routing Protocol Subsystem: it forms unicast forwarding routing table for
lower layers to forward unicast packet.
Multicast Routing Protocol Subsystem: it forms multicast forwarding routing table for
lower layers to forward multicast packet.
MPLS Protocol Subsystem: implement LDP, RSVP-TE, and L2/L3 VPN. Provide
basic MPLS services and label forwarding service.
Statistical Alarm Subsystem: maintain all sorts of statistical alarm and configuration
information, store all kinds of statistical information, and provide query interface
System
Management
subsystem:
provide
file
management,
equipment
SNMP Subsystem: implement SNMP AGENT service; support all the protocol
operations of SNMP agent made in SNMP V1 /V2/V3
59
Encapsulation
Support multiple operating systems and the smooth upgrade of the operating
system.
Monitoring
Monitor the working status of power supply module, fan, voltage, current, and
working temperature.
Provide fast failure location to guarantee high reliability of the product version.
Modular Components
60
Implement E-Line, E-LAN, E-Tree multiple connection modes. Realize the safe
and flexible deployment of hierarchical network.
Support L2/L3 VPN, support multicast VPN service and realize rapid VPN
deployment via unified network management system.
5
5.1
Technical Specifications
Physical Indices
Table 5-1 9000-18E/8E/5E/3E Physical Indices
Item
Dimensio
Input
Power
9000-5E
442*619.5*74
442*308.3*7
442*1819.6*
9.4
40
634
442*797.3*74
442*352.8*7
442*219.4*7
9.4
40
38
AC
DC
Power
9000-8E
DC
n(W*H*D
mm)
9000-18E
442*175*738
-72V-38V
90V286V
100V127V AC/200V240V
4566Hz
4367Hz
HVDC
192V380V
216V312V
DC
2407.5W
2650W
AC
2675W
AC
9000-3E
Module
Output
DC:
Power Module
Redundancy
DC: 2+2
DC: 1+1
DC: 1+1
AC: 1+1
AC: 1+1
<9300W
<4000W
<2500W
<1600W
<250kg
<95kg
<55kg
<35kg
11+1 | 8+8
AC: 8+8
Typical Power
Consumption
Weight
61
Item
9000-18E
9000-8E
9000-5E
9000-3E
Total
28
12
Service
18
Slot
MPU Redundancy
1:1
Fabric Redundancy
6+2
3+1
1+1
Full-meshed
Switching Capacity
28Tbps
12.4Tbps
5.8Tbps
2.32Tbps
Backplane Capacity
57.6Tbps
25.6Tbps
8Tbps
2.4Tbps
Hot Swapping
MTBF
>400,000 hr
MTTR
<0.5 hr
Reliability
>99.999%
Fan Tray
12
Fan
34
10
Redundancy
1+1
1+1
1+1
1+1
Heat
Fan Speed
Linear
Linear
Linear
Linear
Dissipatio
Control
Regulation
Regulation
Regulation
Regulation
DC:
DC:
9084BTU/hr
5908BTU/hr
AC:
AC:
9650BTU/hr
6311BTU/hr
n
Heat
Dissipation
73733BTU/hr
Operating
Temperature
-545
Condition
Humidity
5%~90%
Altitude
5000m
Storage
Temperature
-4070
Condition
Humidity
0%~95%
Altitude
5000m
14633BTU/hr
62
9000-2E10
9000-2E4
442*219.4*220
442*131.5*220
Power Input
-72V-38V DC
-72V-38V DC
1300W
1300W
1+1
1+1
Item
9000-2E10
Weight
9000-2E4
<21kg
<14kg
Total
12
MPU
1: 1
1: 1
PFU
1+1
1+1
PIU
Switching Capacity
320Gbps
240Gbps
Backplane Capacity
1.6Tbps
800Gbps
Hot Swapping
MTBF
>200,000 hr
>200,000 hr
MTTR
<0.5 hr
<0.5 hr
Reliability
>99.999%
>99.999%
Fan Tray
Fan
5+1
3+1
Linear Regulation
Linear Regulation
4098BTU/hr
2117.5BTU/hr
-10~45
-40~65
Humidity
5%~95%
5%~95%
Altitude
5000m
5000m
-45~70
-45~70
Humidity
5%~100%
5%~100%
Altitude
5000m
5000m
Slot
Redundan
Heat Dissipation
cy
Fan Speed
Control
Heat
Dissipation
Temperatu
re
Operating Conditions
Temperatu
re
Storage Conditions
63
5.2
Board
5.2.1
LPC
Table 5-1
Code
Notes
P90E-LPC1001
4 1/4 sub-slots
P90E-LPC4001
2 1/2 sub-slots
P90E-LPC2008
2 1/2 sub-slots
P90E-LPC4008
2 1/2 sub-slots
P90E-LPC10008
2 1/2 sub-slots
P90E-LPC1108
4 1/4 sub-slots
P90E-LPC5208
4 1/4 sub-slots
P90E-LPC5108
P90E-LPC10108
P90E-LPC20108
Table 5-2
sub-slots or 1 full-height
sub-slots
2 1/2 sub-slots or 1 full-height
sub-slots
2 1/2 sub-slots or 1 full-height
sub-slots
Code
64
Description
Description
Notes
P90E-LPCA-4XG
LPCA Line
T-SFP+
Process Card
10GE(SFP+)
P90E-LPCB-4XG
LPCB Line
16GT-SFP+
Process Card
P90E-LPCC-4XG
LPCC Line
16GT-SFP+RJ
Process Card
5.2.2
LIC
Table 5-3
LPC
P90E-8GET-SFP
P90E-8GET-RJ
P90E-4OC48-SFP
P90E-8OC3/OC12-SFP
P90E-LPC1001
P90E-4OC3/OC12-SFP
P90E-4COC3-SFP
P90E-24CE1-DB50
P90E-8OC3/2OC12-SFP
P90E-4OC3/1OC12-SFP
P90E-8COC3A-SFP
P90E-8COC3-SFP
P90E-4COC3A-SFP
P90E-4COC3-SFP-A
P90E-LPC1108
P90E-LPC5208
P90E-24CE1A-DB50-120
P90E-24CE1-DB50-120
P90E-24CE1A-DB50-75
P90E-24CE1-DB50-75
P90E-1XGET-SFP+
P90E-LPC2008
P90E-12GET-SFP
P90E-LPC4008
P90ES-2XGET-SFP+
P90ES-1XGET-SFP+
P90ES-20GET-SFP
P90ES-12GET-SFPRJ
P90ES-2OC192-XFP-O
P90E-LPC4001
P90ES-1OC192-XFP-O
P90ES-8OC48-SFP
P90ES-4OC48A-SFP
P90E-2XGET-SFP+
P90E-24GET-SFP
P90E-20GET-SFP
P90E-LPC4008
P90E-20GET-RJ
P90E-4XGET-SFP+
P90E-2XGET-SFP+-B
P90E-5XGET-XFP-B
P90E-4XGET-XFP
P90E-LPC5108
P90E-LPC10108
P90E-LPC20108
65
Code of LIC
LPC
P90E-2XGET-XFP-B
P90E-1XGET-XFP-B
P90E-2XGE10GET-SFP+
P90E-24GET-SFP-B
P90E-20GET-SFP-B
P90E-12GET-SFP-B
P90E-2XGE16GET-SFP+RJ
P90E-16GET-RJ
P90E-2XGET-SFP+-C
P90E-8GET-SFP-B
P90E-LPC5208
P90E-8GET-RJ-B
P90E-1CGET-CFP-A
P90E-1XLGET-CFP-A
P90E-5XGET-XFP
P90E-5XGET-SFP+
P90E-1OC768-PIN300
P90E-LPC10008
P90E-4OC192-XFP
P90E-2OC192-XFP-O
P90E-1OC192-XFP-O
P90E-1XLGET-CFP
P90E-6XGET-SFP+
P90E-6XGET-XFP
P90E-4XGE20GET-SFP+
P90E-LPC10108/
P90E-LPC20108
P90E-4XGE16GET-SFP+RJ
P90E-1CGET-CFP
P90E-3XLGET-QSFP+
P90E-12XGET-SFP+
P90E-LPC20108
P90E-10XGET-SFP+
P90E-8XGE16GET-SFP+
5-4
LPC
P90EN-2XGET-SFP+
P90EN-8GET-SFP
P90EN-8GET-RJ
P90EN-4A3-SFP
P90EN-8OC3/2OC12-SFP
P90E-LPCA-4XGT-SFP+
P90E-LPCB-4XG16GT-SFP+
P90E-LPCC-4XG16GT-SFP+RJ
P90EN-4OC3/1OC12-SFP
66
Code of LIC
LPC
P90EN-8COC3A-SFP
P90EN-4COC3A-SFP
P90EN-8COC3-SFP
P90EN-4COC3-SFP
P90EN-24CE1A-DB50-120
P90EN-24CE1-DB50-120
P90EN-24CE1A-DB50-75
P90EN-24CE1-DB50-75
5.2.3
MSU
Description
Code
P90E-MSU01
Notes
Multi-service Unit 01
P90E-MIU01-I
Multi-service interface
Unit
1/2 size.
01-I
Typical Scene
6.1
IPRAN
In IPRAN network, ZXCTN 9000-E provides various high speed physical interfaces and
line process cards, supports high availability and fast recovery mechanisms.
67
Figure 6-1
IPRAN network
TDM E1
BTS
NMS
BSC/RNC
MSC
IMA E1/FE
NodeB
SGSN
IMA E1/FE
AGW
MGW
NodeB
GE
eNB
6.2
FMC
Figure 6-2
68
FMC network