Professional Documents
Culture Documents
Conduit and Tubing Fill Tables for Conductors and Fixture Wires of the Same Size
21
(34)
27
(1)
35
(114)
41
(112)
53
(2)
63
(212)
78
(3)
91
(312)
103
(4)
14
12
10
8
6
4
3
2
1
1
7
6
5
2
1
11
9
8
4
3
20
17
13
7
5
27
23
18
9
8
46
38
30
16
13
80
66
53
28
22
120
100
81
42
34
157
131
105
55
44
201
167
135
70
56
4
3
2
1
1
1
1
0
1
1
1
1
2
1
1
1
4
4
3
1
6
5
4
3
10
9
7
5
17
15
13
9
26
23
20
13
34
30
26
17
44
38
33
22
1/0
2/0
3/0
4/0
0
0
0
0
1
1
0
0
1
1
1
1
1
1
1
1
2
2
1
1
4
4
3
3
7
6
5
5
11
10
8
7
15
13
11
9
19
17
14
12
250
300
350
400
500
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
0
1
1
1
1
1
1
1
1
1
1
3
3
3
2
2
5
5
4
4
3
7
6
6
5
4
9
8
7
7
6
600
700
750
800
900
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0
0
0
0
1
1
1
1
1
1
1
1
1
1
3
2
2
2
1
4
3
3
3
3
5
4
4
4
3
1000
1250
1500
1750
2000
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0
0
0
0
1
1
1
1
1
1
1
1
1
1
2
1
1
1
1
3
2
1
1
1
TW
14
12
10
8
8
6
5
2
15
11
8
5
25
19
14
8
43
33
24
13
58
45
33
18
96
74
55
30
168
129
96
53
254
195
145
81
332
255
190
105
424
326
243
135
RHH*, RHW*,
RHW-2*,
THHW, THW,
THW-2
14
10
16
28
39
64
112
169
221
282
RHH*, RHW*,
RHW-2*,
THHW, THW
12
13
23
31
51
90
136
177
227
10
10
18
24
40
70
106
138
177
RHH*, RHW*,
RHW-2*,
THHW, THW,
THW-2
10
14
24
42
63
83
106
RHH*, RHW*,
RHW-2*, TW,
THW, THHW,
THW-2
6
4
3
2
1
1
1
1
1
1
3
1
1
1
1
4
3
3
2
1
8
6
5
4
3
11
8
7
6
4
18
13
12
10
7
32
24
20
17
12
48
36
31
26
18
63
47
40
34
24
81
60
52
44
31
Type
RHH, RHW,
RHW-2
(Continues)
2011
1353
Informative Annex C
Conduit and Tubing Fill Tables for Conductors and Fixture Wires of the Same Size
Type
THHN,
THWN,
THWN-2
FEP, FEPB,
PFA, PFAH,
TFE
1354
Conductor
Size (AWG
kcmil)
16
(12)
21
(34)
27
(1)
35
(114)
1/0
2/0
3/0
4/0
0
0
0
0
1
1
1
0
1
1
1
1
2
1
1
1
250
300
350
400
500
0
0
0
0
0
0
0
0
0
0
1
1
0
0
0
600
700
750
800
900
0
0
0
0
0
0
0
0
0
0
1000
1250
1500
1750
2000
0
0
0
0
0
14
12
10
8
6
41
(112)
53
(2)
63
(212)
78
(3)
91
(312)
103
(4)
3
3
2
1
6
5
4
3
10
9
7
6
16
13
11
9
20
17
15
12
26
22
19
16
1
1
1
1
1
1
1
1
1
1
3
2
1
1
1
5
4
4
3
3
7
6
6
5
4
10
8
7
7
6
13
11
10
9
7
0
0
0
0
0
1
0
0
0
0
1
1
1
1
0
1
1
1
1
1
2
1
1
1
1
3
3
3
3
2
4
4
4
3
3
6
5
5
5
4
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
0
0
1
1
1
1
1
2
1
1
1
1
3
2
1
1
1
4
3
2
2
1
12
9
5
3
2
22
16
10
6
4
35
26
16
9
7
61
45
28
16
12
84
61
38
22
16
138
101
63
36
26
241
176
111
64
46
364
266
167
96
69
476
347
219
126
91
608
443
279
161
116
4
3
2
1
1
1
1
1
2
1
1
1
4
3
3
1
7
6
5
4
10
8
7
5
16
13
11
8
28
24
20
15
43
36
30
22
56
47
40
29
71
60
51
37
1/0
2/0
3/0
4/0
1
0
0
0
1
1
1
1
1
1
1
1
3
2
1
1
4
3
3
2
7
6
5
4
12
10
8
7
19
16
13
11
25
20
17
14
32
26
22
18
250
300
350
400
500
0
0
0
0
0
0
0
0
0
0
1
1
1
0
0
1
1
1
1
1
1
1
1
1
1
3
3
2
1
1
6
5
4
4
3
9
7
6
6
5
11
10
9
8
6
15
13
11
10
8
600
700
750
800
900
1000
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
0
0
0
0
1
1
1
1
1
1
1
1
1
1
1
1
2
2
1
1
1
1
4
3
3
3
3
2
5
4
4
4
3
3
7
6
5
5
4
4
14
12
10
8
12
9
6
3
21
15
11
6
34
25
18
10
60
43
31
18
81
59
42
24
134
98
70
40
234
171
122
70
354
258
185
106
462
337
241
138
590
430
309
177
2011
Informative Annex C
Conduit and Tubing Fill Tables for Conductors and Fixture Wires of the Same Size
21
(34)
27
(1)
35
(114)
41
(112)
53
(2)
63
(212)
78
(3)
91
(312)
103
(4)
6
4
3
2
2
1
1
1
4
3
2
1
7
5
4
3
12
9
7
6
17
12
10
8
28
20
16
13
50
35
29
24
75
53
44
36
98
69
57
47
126
88
73
60
PFA, PFAH,
TFE
16
25
33
42
PFAH, TFE
PFA, PFAH,
TFE, Z
1/0
2/0
3/0
4/0
1
0
0
0
1
1
1
1
1
1
1
1
3
3
2
1
5
4
3
2
8
6
5
4
14
11
9
8
21
17
14
11
27
22
18
15
35
29
24
19
14
12
10
8
6
14
10
6
4
3
25
18
11
7
5
41
29
18
11
8
72
51
31
20
14
98
69
42
27
19
161
114
70
44
31
282
200
122
77
54
426
302
185
117
82
556
394
241
153
107
711
504
309
195
137
4
3
2
1
1
1
1
1
3
2
1
1
5
4
3
2
9
7
6
4
13
9
8
6
21
15
13
10
37
27
22
18
56
41
34
28
74
54
45
36
94
69
57
46
14
12
10
8
8
6
5
2
15
11
8
5
25
19
14
8
43
33
24
13
58
45
33
18
96
74
55
30
168
129
96
53
254
195
145
81
332
255
190
105
424
326
243
135
6
4
3
2
1
1
1
1
3
2
1
1
6
4
3
3
10
7
6
5
14
10
8
7
22
16
14
11
39
28
24
20
60
43
36
31
78
56
48
40
100
72
61
51
1
1/0
2/0
3/0
4/0
1
1
0
0
0
1
1
1
1
1
1
1
1
1
1
4
3
2
1
1
5
4
3
3
2
8
7
6
5
4
15
13
10
9
7
23
19
16
13
11
30
25
21
17
14
38
32
27
22
18
250
300
350
400
500
600
700
750
800
900
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
0
0
0
0
0
0
0
1
1
1
1
1
1
0
0
0
0
1
1
1
1
1
1
1
1
1
1
3
3
2
1
1
1
1
1
1
1
6
5
4
4
3
2
2
1
1
1
9
8
7
6
5
4
3
3
3
3
12
10
9
8
6
5
4
4
4
3
15
13
11
10
8
6
6
5
5
4
1000
1250
1500
1750
2000
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
0
0
1
1
1
1
1
2
1
1
1
1
3
2
1
1
1
4
3
3
2
1
Type
XHH, XHHW,
XHHW-2, ZW
XHH, XHHW,
XHHW-2
(Continues)
2011
1355
Informative Annex C
Conduit and Tubing Fill Tables for Conductors and Fixture Wires of the Same Size
Conductor
Size (AWG/
kcmil)
16
(12)
21
(34)
27
(1)
35
(114)
41
(112)
53
(2)
FFH-2, RFH-2,
RFHH-3
18
16
8
7
14
12
24
20
41
34
56
47
92
78
SF-2, SFF-2
18
16
14
10
8
7
18
15
12
30
25
20
52
43
34
71
58
47
116
96
78
SF-1, SFF-1
18
18
33
53
92
125
206
RFH-1, RFHH-2,
TF, TFF, XF, XFF
18
14
24
39
68
92
152
16
11
19
31
55
74
123
XF, XFF
14
15
25
43
58
96
TFN, TFFN
18
16
22
17
38
29
63
48
108
83
148
113
244
186
18
16
14
21
16
12
36
28
21
59
46
34
103
79
60
140
108
81
231
179
134
18
16
14
27
20
14
47
35
25
77
56
41
133
98
72
181
133
98
298
220
161
KF-2, KFF-2
18
16
14
12
10
39
27
19
13
8
69
48
33
23
15
111
78
54
37
25
193
136
93
64
43
262
185
127
87
58
433
305
209
144
96
KF-1, KFF-1
18
16
14
12
10
46
33
22
14
9
82
57
38
25
16
133
93
63
41
27
230
161
108
72
47
313
220
148
98
64
516
362
244
161
105
XF, XFF
12
10
4
3
8
6
13
10
23
18
31
24
51
40
Type
Notes:
1. This table is for concentric stranded conductors only. For compact stranded conductors, Table C.1(A)
should be used.
2. Two-hour fire-rated RHH cable has ceramifiable insulation which has much larger diameters than other
RHH wires. Consult manufacturers conduit fill tables.
*Types RHH, RHW, and RHW-2 without outer covering.
1356
2011
Informative Annex C
Conduit and Tubing Fill Tables for Conductors and Fixture Wires of the Same Size
Type
THW, THW-2,
THHW
THHN,
THWN,
THWN-2
XHHW,
XHHW-2
Conductor
Size (AWG/
kcmil)
16
(12)
21
(34)
27
(1)
35
(114)
41
(112)
53
(2)
63
(212)
78
(3)
91
(312)
103
(4)
8
6
4
2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
700
750
900
1000
8
6
4
2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
700
750
900
1000
8
6
4
2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
700
750
900
1000
2
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
2
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
3
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
4
3
2
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
4
3
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
5
4
3
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
6
5
4
3
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
7
4
3
2
1
1
1
1
1
1
1
1
0
0
0
0
0
0
8
6
4
3
2
1
1
1
1
1
1
1
1
0
0
0
0
0
0
11
9
6
5
3
3
2
1
1
1
1
1
1
1
1
1
0
0
0
13
8
6
4
3
3
2
1
1
1
1
1
1
1
1
1
0
0
15
11
8
6
4
3
3
2
1
1
1
1
1
1
1
1
1
0
0
16
12
9
7
4
4
3
3
2
1
1
1
1
1
1
1
1
1
1
18
11
8
6
5
4
3
3
1
1
1
1
1
1
1
1
1
1
20
15
11
8
6
5
4
3
3
2
1
1
1
1
1
1
1
1
1
26
20
15
11
8
7
5
5
4
3
3
2
1
1
1
1
1
1
1
29
18
13
10
8
7
6
5
4
3
3
2
1
1
1
1
1
1
34
25
18
13
10
8
7
6
5
4
3
3
2
1
1
1
1
1
1
46
35
26
19
13
12
10
8
7
5
5
4
4
3
2
2
1
2
1
52
32
23
17
14
12
10
8
6
5
5
4
4
3
2
2
2
1
59
44
32
23
17
14
12
10
8
7
6
5
4
4
3
2
2
2
1
69
53
40
29
21
18
15
13
11
8
7
6
6
5
4
3
3
3
2
78
48
34
26
22
18
15
12
10
8
7
6
5
4
4
4
3
3
90
66
48
34
26
22
18
15
13
10
9
8
7
6
4
4
3
3
3
90
70
52
38
27
23
20
17
14
11
9
8
8
6
5
4
4
4
3
102
63
45
34
29
24
20
16
13
11
10
9
7
6
5
5
4
3
117
87
63
45
34
29
24
20
17
13
11
10
9
7
6
5
5
4
4
115
89
67
49
34
30
25
21
18
14
12
11
10
8
7
6
5
5
4
130
81
58
43
37
30
25
21
16
14
12
11
9
7
7
6
5
4
149
111
81
58
43
37
31
25
21
17
14
13
11
9
8
7
6
5
5
Definition: Compact stranding is the result of a manufacturing process where the standard conductor is
compressed to the extent that the interstices (voids between strand wires) are virtually eliminated.
2011
1357
Informative Annex C
Conduit and Tubing Fill Tables for Conductors and Fixture Wires of the Same Size
21
(34)
27
(1)
35
(114)
41
(112)
14
12
10
8
6
3
2
1
1
1
6
5
4
1
1
10
9
7
3
3
19
16
13
6
5
26
22
17
9
7
43
36
29
15
12
4
3
2
1
1
1
0
0
1
1
1
1
2
1
1
1
4
3
3
1
6
5
4
3
9
8
7
5
1/0
2/0
3/0
4/0
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
2
1
1
1
4
3
3
2
250
300
350
400
500
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
0
1
1
1
1
1
1
1
1
1
1
600
700
750
800
900
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0
0
0
0
1
1
1
1
1
1000
1250
1500
1750
2000
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0
0
0
0
TW
14
12
10
8
7
5
4
1
13
10
7
4
22
17
13
7
40
31
23
13
55
42
32
17
92
71
52
29
RHH*, RHW*,
RHW-2*, THHW,
THW, THW-2
14
15
27
37
61
RHH*, RHW*,
RHW-2*, THHW,
THW
12
12
21
29
49
10
17
23
38
RHH*, RHW*,
RHW-2*, THHW,
THW, THW-2
10
14
23
RHH*, RHW*,
RHW-2*, TW,
THW, THHW,
THW-2
6
4
3
2
1
1
1
1
1
0
2
1
1
1
1
4
3
2
2
1
7
5
5
4
3
10
8
7
6
4
17
13
11
9
6
Type
RHH, RHW,
RHW-2
1358
53
(2)
2011
Informative Annex C
Conduit and Tubing Fill Tables for Conductors and Fixture Wires of the Same Size
Type
THHN, THWN,
THWN-2
Conductor
Size (AWG/
kcmil)
21
(34)
27
(1)
35
(114)
41
(112)
53
(2)
1/0
2/0
3/0
4/0
0
0
0
0
1
1
0
0
1
1
1
1
2
1
1
1
3
3
2
1
5
5
4
3
250
300
350
400
500
0
0
0
0
0
0
0
0
0
0
1
0
0
0
0
1
1
1
1
1
1
1
1
1
1
2
2
1
1
1
600
700
750
800
900
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
0
1
1
1
1
1
1000
1250
1500
1750
2000
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
0
0
0
14
12
10
8
6
10
7
4
2
1
18
13
8
5
3
32
23
15
8
6
58
42
26
15
11
80
58
36
21
15
132
96
60
35
25
4
3
2
1
1
1
1
1
1
1
1
1
4
3
2
1
7
5
5
3
9
8
6
5
15
13
11
8
1/0
2/0
3/0
4/0
0
0
0
0
1
1
1
0
1
1
1
1
3
2
1
1
4
3
3
2
7
5
4
4
250
300
350
400
500
0
0
0
0
0
0
0
0
0
0
1
1
0
0
0
1
1
1
1
1
1
1
1
1
1
3
2
2
1
1
600
700
750
800
900
1000
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0
0
0
0
0
1
1
1
1
1
0
1
1
1
1
1
1
14
12
10
8
10
7
5
3
18
13
9
5
31
23
16
9
56
41
29
17
77
56
40
23
128
93
67
38
(Continues)
2011
1359
Informative Annex C
Conduit and Tubing Fill Tables for Conductors and Fixture Wires of the Same Size
21
(34)
27
(1)
6
4
3
2
1
1
1
1
4
2
1
1
1/0
2/0
3/0
4/0
Type
XHH, XHHW,
XHHW-2, ZW
XHH, XHHW,
XHHW-2
1360
35
(114)
41
(112)
53
(2)
6
4
4
3
12
8
7
5
16
11
9
8
27
19
16
13
0
0
0
0
1
1
1
1
1
1
1
1
3
2
1
1
4
4
3
2
7
6
5
4
14
12
10
8
6
12
8
5
3
1
22
15
9
6
4
38
27
16
10
7
68
48
29
18
13
93
66
40
25
18
154
4
3
2
1
1
1
1
1
3
1
1
1
5
3
3
2
9
6
5
4
12
9
7
6
20
15
12
10
14
12
10
8
6
7
5
4
1
1
13
10
7
4
3
22
17
13
7
5
40
31
23
13
9
55
42
32
17
13
92
71
52
29
21
4
3
2
1
1
1
1
1
1
4
3
2
7
6
5
9
8
6
15
13
11
1
1/0
2/0
3/0
4/0
1
0
0
0
0
1
1
1
1
0
1
1
1
1
1
3
3
2
1
1
5
4
3
3
2
8
7
6
5
4
250
300
350
400
500
0
0
0
0
0
0
0
0
0
0
1
1
1
0
0
1
1
1
1
1
1
1
1
1
1
3
3
2
1
1
600
700
750
800
900
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0
0
0
0
1
1
1
1
1
1
1
1
1
1
1000
1250
1500
1750
2000
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
0
0
109
67
42
30
2011
Informative Annex C
Conduit and Tubing Fill Tables for Conductors and Fixture Wires of the Same Size
Type
Conductor
Size (AWG/
kcmil)
21
(34)
27
(1)
35
(114)
41
(112)
53
(2)
FFH-2, RFH-2,
RFHH-3 SF-2,
SFF-2
18
16
6
5
12
10
21
18
39
32
53
45
88
74
18
16
14
8
7
5
15
13
10
27
22
18
49
40
32
67
55
45
111
92
74
SF-1, SFF-1
18
15
28
48
86
119
197
RFH-1, RFHH-2,
TF, TFF, XF, XFF
18
11
20
35
64
88
145
16
16
29
51
71
117
XF, XFF
14
13
22
40
55
92
TFN, TFFN
18
16
18
13
33
25
57
43
102
78
141
107
233
178
18
16
14
17
13
10
31
24
18
54
42
31
97
75
56
133
103
77
221
171
128
18
16
14
22
16
12
40
29
22
70
51
38
125
92
68
172
127
93
285
210
154
KF-2, KFF-2
18
16
14
12
10
31
22
15
10
7
58
41
28
19
13
101
71
49
33
22
182
128
88
60
40
250
176
121
83
55
413
291
200
138
92
KF-1, KFF-1
18
16
14
12
10
38
26
18
12
7
69
49
33
22
14
121
85
57
38
24
217
152
102
68
44
298
209
141
93
61
493
346
233
154
101
XF, XFF
12
10
3
3
7
5
12
9
21
17
29
23
49
38
Notes:
1. This table is for concentric stranded conductors only. For compact stranded conductors, Table C.2(A)
should be used.
2. Two-hour fire-rated RHH cable has ceramifiable insulation which has much larger diameters than other
RHH wires. Consult manufacturers conduit fill tables.
*Types RHH, RHW, and RHW-2 without outer covering.
2011
1361
Informative Annex C
Conduit and Tubing Fill Tables for Conductors and Fixture Wires of the Same Size
Type
THW, THW-2,
THHW
THHN, THWN,
THWN-2
XHHW, XHHW-2
Conductor
Size (AWG/
kcmil)
16
(12)
21
(34)
27
(1)
35
(114)
41
(112)
53
(2)
8
6
4
2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
700
750
900
1000
8
6
4
2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
700
750
900
1000
8
6
4
2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
700
750
900
1000
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
2
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
3
2
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
4
2
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
4
3
2
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
6
4
3
2
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
7
4
3
2
1
1
1
1
1
1
1
0
0
0
0
0
0
0
8
6
4
3
2
1
1
1
1
1
1
1
1
0
0
0
0
0
0
11
8
6
4
3
3
2
1
1
1
1
1
1
1
1
0
0
0
0
12
7
5
4
3
3
2
1
1
1
1
1
1
1
1
1
0
0
14
10
7
5
4
3
3
2
1
1
1
1
1
1
1
1
1
0
0
15
11
8
6
4
4
3
3
2
1
1
1
1
1
1
1
1
1
0
17
10
7
5
5
4
3
2
1
1
1
1
1
1
1
1
1
1
19
14
10
7
5
5
4
3
3
1
1
1
1
1
1
1
1
1
1
25
19
14
10
7
6
5
4
4
3
2
2
1
1
1
1
1
1
1
28
17
12
9
8
6
5
4
3
3
2
2
1
1
1
1
1
1
32
24
17
12
9
8
7
5
4
3
3
3
2
1
1
1
1
1
1
Definition: Compact stranding is the result of a manufacturing process where the standard conductor is
compressed to the extent that the interstices (voids between strand wires) are virtually eliminated.
1362
2011
Informative Annex C
Conduit and Tubing Fill Tables for Conductors and Fixture Wires of the Same Size
TABLE C.3 Maximum Number of Conductors or Fixture Wires in Flexible Metal Conduit
(FMC) (Based on Table 1, Chapter 9)
CONDUCTORS
Conductor
Size (AWG/
kcmil)
21
(34)
27
(1)
35
(114)
41
(112)
53
(2)
63
(212)
78
(3)
91
(312)
103
(4)
14
12
10
8
6
4
3
2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
700
750
800
900
1000
1250
1500
1750
2000
14
12
10
8
4
3
3
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
9
7
5
3
7
6
5
2
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
15
11
8
5
11
9
7
4
3
2
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
23
18
13
7
17
14
11
6
5
4
3
3
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
36
28
21
11
25
21
17
9
7
5
5
4
2
2
1
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
53
41
30
17
44
37
30
15
12
10
8
7
5
4
3
3
2
1
1
1
1
1
1
1
1
1
1
1
0
0
0
0
94
72
54
30
67
55
45
23
19
14
13
11
7
6
5
5
4
3
2
2
1
1
1
1
1
1
1
1
1
1
1
0
141
108
81
45
96
80
64
34
27
21
18
16
10
9
8
7
6
4
4
3
3
3
2
1
1
1
1
1
1
1
1
1
203
156
116
64
131
109
88
46
37
29
25
22
14
12
11
9
8
6
5
5
4
4
3
3
2
2
2
1
1
1
1
1
277
212
158
88
171
142
115
60
48
37
33
28
19
16
14
12
10
8
7
6
6
5
4
3
3
3
3
3
1
1
1
1
361
277
207
115
RHH*, RHW*,
RHW-2*,
THHW, THW,
THW-2
RHH*, RHW*,
RHW-2*,
THHW, THW
14
10
15
24
35
62
94
135
184
240
12
12
19
28
50
75
108
148
193
10
10
15
22
39
59
85
115
151
RHH*, RHW*,
RHW-2*,
THHW, THW,
THW-2
RHH*, RHW*,
RHW-2*, TW,
THW, THHW,
THW-2
13
23
35
51
69
90
6
4
3
2
1
1
1
1
1
1
3
1
1
1
1
4
3
3
2
1
7
5
4
4
2
10
7
6
5
4
18
13
11
10
7
27
20
17
14
10
39
29
25
21
15
53
39
34
29
20
69
51
44
37
26
Type
RHH, RHW,
RHW-2
TW
(Continues)
2011
1363
Informative Annex C
Conduit and Tubing Fill Tables for Conductors and Fixture Wires of the Same Size
Type
THHN,
THWN,
THWN-2
FEP, FEPB,
PFA, PFAH,
TFE
1364
Conductor
Size (AWG/
kcmil)
21
(34)
27
(1)
35
(114)
41
(112)
53
(2)
63
(212)
78
(3)
91
(312)
103
(4)
1/0
2/0
3/0
4/0
250
300
350
400
500
600
700
750
800
900
1000
1250
1500
1750
2000
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
3
3
2
1
1
1
1
1
1
1
1
1
1
0
0
0
0
0
0
6
5
4
3
3
2
1
1
1
1
1
1
1
1
1
1
0
0
0
9
7
6
5
4
3
3
3
2
1
1
1
1
1
1
1
1
1
1
12
10
9
7
6
5
4
4
3
3
2
2
1
1
1
1
1
1
1
17
14
12
10
8
7
6
6
5
4
3
3
3
3
2
1
1
1
1
22
19
16
13
11
9
8
7
6
5
4
4
4
3
3
2
1
1
1
14
12
10
8
6
4
3
2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
700
750
800
900
1000
13
9
6
3
2
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
22
16
10
6
4
2
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
33
24
15
9
6
4
3
3
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
52
38
24
14
10
6
5
4
3
2
1
1
1
1
1
1
1
1
0
0
0
0
0
0
76
56
35
20
14
9
7
6
4
4
3
2
1
1
1
1
1
1
1
1
1
1
0
0
134
98
62
35
25
16
13
11
8
7
6
5
4
3
3
2
1
1
1
1
1
1
1
1
202
147
93
53
38
24
20
17
12
10
9
7
6
5
4
3
3
2
1
1
1
1
1
1
291
212
134
77
55
34
29
24
18
15
12
10
8
7
6
5
5
4
3
3
2
2
1
1
396
289
182
105
76
46
39
33
24
20
17
14
12
9
8
7
6
5
4
4
3
3
3
3
518
378
238
137
99
61
51
43
32
27
22
18
15
12
11
9
8
7
5
5
4
4
4
3
14
12
10
8
12
9
6
4
21
15
11
6
32
24
17
10
51
37
26
15
74
54
39
22
130
95
68
39
196
143
103
59
282
206
148
85
385
281
201
115
502
367
263
151
2011
Informative Annex C
Conduit and Tubing Fill Tables for Conductors and Fixture Wires of the Same Size
21
(34)
27
(1)
35
(114)
41
(112)
53
(2)
63
(212)
78
(3)
91
(312)
103
(4)
6
4
3
2
2
1
1
1
4
3
2
1
7
5
4
3
11
7
6
5
16
11
9
7
28
19
16
13
42
29
24
20
60
42
35
29
82
57
48
39
107
75
62
51
14
20
27
36
1/0
2/0
3/0
4/0
1
1
0
0
1
1
1
1
1
1
1
1
3
2
1
1
4
3
3
2
8
6
5
4
11
9
8
6
17
14
11
9
23
19
15
13
30
24
20
16
14
12
10
8
6
4
3
2
1
15
11
6
4
3
1
1
1
1
25
18
11
7
5
3
2
1
1
39
28
17
11
7
5
4
3
2
61
43
26
17
12
8
6
5
4
89
63
39
24
17
12
8
7
6
157
111
68
43
30
21
15
12
10
236
168
103
65
45
31
23
19
15
340
241
148
93
65
45
33
27
22
463
329
201
127
89
61
45
37
30
605
429
263
166
117
80
58
49
39
XHH, XHHW,
XHHW-2, ZW
14
12
10
8
6
4
3
2
9
7
5
3
1
1
1
1
15
11
8
5
3
2
1
1
23
18
13
7
5
4
3
3
36
28
21
11
8
6
5
4
53
41
30
17
12
9
7
6
94
72
54
30
22
16
13
11
141
108
81
45
33
24
20
17
203
156
116
64
48
34
29
24
277
212
158
88
65
47
40
33
361
277
207
115
85
61
52
44
XHH, XHHW,
XHHW-2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
700
750
800
900
1000
1250
1500
1750
2000
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
3
2
2
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
5
4
3
3
2
1
1
1
1
1
1
1
1
1
0
0
0
0
0
0
8
7
6
5
4
3
3
2
1
1
1
1
1
1
1
1
1
1
0
0
13
10
9
7
6
5
4
4
3
3
1
1
1
1
1
1
1
1
1
1
18
15
13
10
9
7
6
5
5
4
3
3
2
2
1
1
1
1
1
1
25
21
17
14
12
10
8
7
6
5
4
4
3
3
3
3
1
1
1
1
32
27
23
19
15
13
11
9
8
7
5
5
4
4
4
3
3
2
1
1
Type
PFA, PFAH,
TFE
PFA, PFAH,
TFE, Z
(Continues)
2011
1365
Informative Annex C
Conduit and Tubing Fill Tables for Conductors and Fixture Wires of the Same Size
Type
FFH-2, RFH-2,
RFHH-3
SF-2, SFF-2
SF-1, SFF-1
RFH-1, RFHH-2,
TF, TFF, XF, XFF
RFHH-2, TF, TFF,
XF, XFF
XF, XFF
TFN, TFFN
PF, PFF, PGF,
PGFF, PAF, PTF,
PTFF, PAFF
ZF, ZFF, ZHF, HF,
HFF
KF-2, KFF-2
KF-1, KFF-1
XF, XFF
Conductor
Size (AWG/
kcmil)
16
(12)
21
(34)
18
16
18
16
14
18
18
8
7
11
9
7
19
14
14
12
18
15
12
32
24
16
11
14
18
16
18
16
14
18
16
14
18
16
14
12
10
18
16
14
12
10
12
10
9
23
17
22
17
12
28
20
15
41
28
19
13
9
48
34
23
15
10
5
4
27
(1)
35
(114)
41
(112)
53
(2)
22
19
28
23
19
50
37
35
29
44
36
29
78
58
51
43
64
53
43
114
84
90
76
113
94
76
201
148
19
30
47
68
120
15
38
29
36
28
21
47
35
25
68
48
33
23
15
82
57
38
25
16
8
6
23
59
45
56
43
32
72
53
39
105
74
51
35
23
125
88
59
39
25
12
10
36
93
71
88
68
51
113
83
61
164
116
80
55
36
196
138
93
61
40
19
15
53
135
103
128
99
74
165
121
89
239
168
116
80
53
285
200
135
89
58
28
22
94
237
181
225
174
130
290
214
157
421
297
204
140
94
503
353
237
157
103
50
39
Notes:
1. This table is for concentric stranded conductors only. For compact stranded conductors, Table C.3(A)
should be used.
2. Two-hour fire-rated RHH cable has ceramifiable insulation which has much larger diameters than other
RHH wires. Consult manufacturers conduit fill tables.
*
Types RHH, RHW, and RHW-2 without outer covering.
1366
2011
Informative Annex C
Conduit and Tubing Fill Tables for Conductors and Fixture Wires of the Same Size
Type
THW, THHW,
THW-2
THHN,
THWN,
THWN-2
XHHW,
XHHW-2
Conductor
Size (AWG/
kcmil)
16
(12)
21
(34)
27
(1)
35
(114)
41
(112)
53
(2)
63
(212)
78
(3)
91
(312)
103
(4)
8
6
4
2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
700
750
900
1000
8
6
4
2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
700
750
900
1000
8
6
4
2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
700
750
900
1000
2
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
3
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
3
2
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
4
3
2
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
4
3
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
5
4
3
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
6
5
3
2
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
7
4
3
2
1
1
1
1
1
1
1
1
0
0
0
0
0
0
8
6
4
3
2
1
1
1
1
1
1
1
1
0
0
0
0
0
0
10
7
5
4
3
2
1
1
1
1
1
1
1
1
0
0
0
0
0
11
7
5
3
3
2
1
1
1
1
1
1
1
1
0
0
0
0
13
9
7
5
3
3
2
1
1
1
1
1
1
1
1
0
0
0
0
14
11
8
6
4
3
3
2
1
1
1
1
1
1
1
1
1
1
0
16
10
7
5
4
4
3
2
1
1
1
1
1
1
1
1
1
0
19
14
10
7
5
4
4
3
2
1
1
1
1
1
1
1
1
1
1
25
20
15
11
7
6
5
4
4
3
2
2
1
1
1
1
1
1
1
29
18
13
9
8
6
5
4
3
3
3
2
1
1
1
1
1
1
33
24
18
13
9
8
7
5
4
4
3
3
2
1
1
1
1
1
1
38
29
22
16
11
10
8
7
6
4
4
3
3
3
1
1
1
1
1
43
27
19
14
12
10
8
7
5
5
4
3
3
2
1
1
1
1
50
37
27
19
14
12
10
8
7
5
5
4
4
3
2
1
1
2
1
55
43
32
23
16
14
12
10
8
7
6
5
5
4
3
3
2
2
1
62
38
28
21
17
14
12
10
8
7
6
5
4
3
3
3
2
1
71
53
38
28
21
17
15
12
10
8
7
6
5
4
3
3
3
2
2
75
58
43
32
22
19
16
14
11
9
8
7
6
5
4
4
3
3
3
85
52
38
28
24
20
17
14
11
9
8
7
6
5
4
4
3
3
97
72
52
38
28
24
20
17
14
11
9
8
7
6
5
4
4
3
3
98
76
57
42
29
25
21
18
15
12
10
9
8
7
6
5
5
4
4
111
69
49
37
31
26
22
18
14
12
10
9
8
6
6
5
4
4
127
95
69
49
37
31
26
22
18
14
12
11
10
8
6
6
5
4
4
Definition: Compact stranding is the result of a manufacturing process where the standard conductor is
compressed to the extent that the interstices (voids between strand wires) are virtually eliminated.
2011
1367
Informative Annex C
Conduit and Tubing Fill Tables for Conductors and Fixture Wires of the Same Size
Type
RHH, RHW,
RHW-2
RHH, RHW,
RHW-2
TW
RHH*, RHW*,
RHW-2*,
THHW, THW,
THW-2
RHH*, RHW*,
RHW-2*,
THHW, THW
RHH*, RHW*,
RHW-2*,
THHW, THW,
THW-2
RHH*, RHW*,
RHW-2*, TW,
THHW, THW,
THW-2
1368
Conductor
Size (AWG/
kcmil)
16
(12)
21
(34)
27
(1)
35
(114)
41
(112)
53
(2)
63
(212)
78
(3)
91
(312)
103
(4)
14
12
10
8
6
4
3
2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
700
750
800
900
1000
1250
1500
1750
2000
14
12
10
8
14
4
4
3
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
10
7
5
3
6
8
6
5
3
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
17
13
9
5
11
13
11
8
4
3
3
2
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
27
21
15
8
18
22
18
15
8
6
5
4
3
2
1
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
47
36
27
15
31
30
25
20
10
8
6
6
5
3
3
2
1
1
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
64
49
36
20
42
49
41
33
17
14
11
9
8
5
4
4
3
3
1
1
1
1
1
1
1
1
1
1
1
1
0
0
0
104
80
59
33
69
70
58
47
24
19
15
13
11
7
6
6
5
4
3
3
2
2
1
1
1
1
1
1
1
1
1
1
1
147
113
84
47
98
108
89
72
38
30
23
21
18
12
10
9
7
6
5
4
4
3
3
2
2
1
1
1
1
1
1
1
1
228
175
130
72
151
144
120
97
50
40
31
28
24
16
14
12
10
9
6
6
5
5
4
3
3
3
3
2
2
1
1
1
1
304
234
174
97
202
186
154
124
65
52
41
36
31
20
18
15
13
11
8
7
7
6
5
4
4
4
3
3
3
2
1
1
1
392
301
224
124
261
12
14
25
34
56
79
122
163
209
10
11
19
26
43
61
95
127
163
12
16
26
37
57
76
98
12
20
28
43
58
75
15
21
32
43
56
2011
Informative Annex C
Conduit and Tubing Fill Tables for Conductors and Fixture Wires of the Same Size
Type
RHH*, RHW*,
RHW-2*, TW,
THW, THHW,
THW-2
THHN,
THWN,
THWN-2
Conductor
Size (AWG/
kcmil)
21
(34)
27
(1)
35
(114)
3
2
1
1/0
2/0
3/0
4/0
1
1
1
1
0
0
0
1
1
1
1
1
1
1
3
3
1
1
1
1
1
6
5
3
3
2
1
1
250
300
350
400
500
0
0
0
0
0
0
0
0
0
0
1
1
1
0
0
600
700
750
800
900
0
0
0
0
0
0
0
0
0
0
1000
1250
1500
1750
2000
0
0
0
0
0
14
12
10
8
6
41
(112)
53
(2)
63
(212)
78
(3)
91
(312)
103
(4)
8
6
4
4
3
3
2
13
11
7
6
5
4
4
18
15
11
9
8
6
5
28
23
16
14
12
10
8
37
31
22
19
16
13
11
48
41
28
24
20
17
14
1
1
1
1
1
1
1
1
1
1
3
2
2
1
1
4
4
3
3
2
7
6
5
4
4
9
8
7
6
5
12
10
9
8
7
0
0
0
0
0
1
0
0
0
0
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
3
3
2
2
2
4
4
3
3
3
5
5
4
4
4
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
0
0
1
1
1
1
1
1
1
1
1
1
3
1
1
1
1
3
3
2
1
1
14
10
6
3
2
24
17
11
6
4
39
29
18
10
7
68
49
31
18
13
91
67
42
24
17
149
109
68
39
28
211
154
97
56
40
326
238
150
86
62
436
318
200
115
83
562
410
258
149
107
4
3
2
1
1
1
1
1
3
2
1
1
4
4
3
2
8
6
5
4
10
9
7
5
17
15
12
9
25
21
17
13
38
32
27
20
51
43
36
27
66
56
47
35
1/0
2/0
3/0
4/0
1
1
0
0
1
1
1
1
1
1
1
1
3
3
2
1
4
4
3
2
8
6
5
4
11
9
7
6
17
14
12
9
23
19
16
13
29
24
20
17
250
300
350
400
500
0
0
0
0
0
0
0
0
0
0
1
1
1
1
0
1
1
1
1
1
1
1
1
1
1
3
3
2
2
1
5
4
4
3
3
8
7
6
5
4
10
9
8
7
6
13
12
10
9
7
600
700
750
800
900
1000
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
0
0
0
1
1
1
1
1
1
1
1
1
1
1
1
2
1
1
1
1
1
3
3
3
3
2
2
5
4
4
4
3
3
6
5
5
5
4
4
(Continues)
2011
1369
Informative Annex C
Conduit and Tubing Fill Tables for Conductors and Fixture Wires of the Same Size
Type
FEP, FEPB,
PFA, PFAH,
TFE
PFA, PFAH,
TFE
PFA, PFAH,
TFE, Z
XHH, XHHW,
XHHW-2, ZW
XHH, XHHW,
XHHW-2
1370
Conductor
Size (AWG/
kcmil)
21
(34)
27
(1)
35
(114)
41
(112)
53
(2)
63
(212)
78
(3)
91
(312)
103
(4)
14
12
10
8
6
4
3
2
1
13
10
7
4
3
1
1
1
1
23
17
12
7
5
3
3
2
1
38
28
20
11
8
5
4
4
2
66
48
34
19
14
10
8
6
4
89
65
46
26
19
13
11
9
6
145
106
76
43
31
21
18
15
10
205
150
107
61
44
30
25
21
14
317
231
166
95
67
47
39
32
22
423
309
221
127
90
63
52
43
30
545
398
285
163
116
81
68
56
39
1/0
2/0
3/0
4/0
14
12
10
8
6
4
3
2
1
14
12
10
8
6
4
3
2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
700
750
800
900
1000
1250
1500
1750
2000
1
1
0
0
16
11
7
4
3
1
1
1
1
10
7
5
3
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
28
20
12
7
5
3
2
1
1
17
13
9
5
4
3
2
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
46
32
20
12
9
6
4
3
3
27
21
15
8
6
4
4
3
2
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
4
3
2
1
79
56
34
21
15
10
7
6
5
47
36
27
15
11
8
7
5
4
3
3
2
1
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
5
4
3
3
107
76
46
29
20
14
10
8
7
64
49
36
20
15
11
9
7
5
5
4
3
2
1
1
1
1
1
1
1
1
1
1
1
0
0
0
0
8
7
6
5
175
124
76
48
33
23
17
14
11
104
80
59
33
24
18
15
12
9
8
6
5
4
3
3
3
2
1
1
1
1
1
1
1
1
1
1
0
12
10
8
7
247
175
107
68
47
33
24
20
16
147
113
84
47
35
25
21
18
13
11
9
7
6
5
4
4
3
3
2
1
1
1
1
1
1
1
1
1
19
15
13
10
381
271
166
105
73
50
37
30
25
228
175
130
72
53
39
33
27
20
17
14
12
10
8
7
6
5
4
3
3
3
3
2
2
1
1
1
1
25
21
17
14
510
362
221
140
98
67
49
41
33
304
234
174
97
71
52
44
37
27
23
19
16
13
11
9
8
7
6
5
4
4
4
3
3
2
1
1
1
32
27
22
18
657
466
285
180
127
87
63
53
43
392
301
224
124
92
67
56
47
35
30
25
20
17
14
12
10
9
8
6
5
5
5
4
4
3
2
2
1
2011
Informative Annex C
Conduit and Tubing Fill Tables for Conductors and Fixture Wires of the Same Size
Type
FHH-2, RFH-2,
RFHH-3
SF-2, SFF-2
SF-1, SFF-1
RFH-1, RFHH-2,
TF, TFF, XF, XFF
RFH-2, TF, TFF,
XF, XFF
XF, XFF
TFN, TFFN
PF, PFF, PGF,
PGFF, PAF, PTF,
PTFF, PAFF
ZF, ZFF, ZHF, HF,
HFF
KF-2, KFF-2
KF-1, KFF-1
XF, XFF
Conductor
Size (AWG/
kcmil)
16
(12)
21
(34)
27
(1)
35
(114)
41
(112)
53
(2)
18
16
18
16
14
18
18
9
8
12
10
8
21
15
16
13
20
17
13
36
26
26
22
33
27
22
59
43
45
38
57
47
38
101
75
61
51
77
64
51
137
101
100
84
126
104
84
223
165
16
12
21
35
60
81
133
14
18
16
18
16
14
18
16
14
10
25
19
23
18
13
30
22
16
17
42
32
40
31
23
52
38
28
27
69
53
66
51
38
85
63
46
47
119
91
113
87
66
146
108
79
64
161
123
153
118
89
197
145
107
104
264
201
250
193
145
322
238
175
18
16
14
12
10
18
16
14
12
10
12
10
44
31
21
14
10
52
37
25
16
10
5
4
75
53
36
25
17
90
63
42
28
18
9
7
123
87
60
41
27
147
103
69
46
30
14
11
212
149
103
70
47
253
178
119
79
52
25
19
287
202
139
95
64
342
240
161
107
70
34
26
468
330
227
156
104
558
392
264
175
114
56
43
Notes:
1. This table is for concentric stranded conductors only. For compact stranded conductors, Table C.4(A)
should be used.
2. Two-hour fire-rated RHH cable has ceramifiable insulation which has much larger diameters than other
RHH wires. Consult manufacturers conduit fill tables.
*
Types RHH, RHW, and RHW-2 without outer covering.
2011
1371
Informative Annex C
Conduit and Tubing Fill Tables for Conductors and Fixture Wires of the Same Size
Type
THW, THW-2,
THHW
THHN,
THWN,
THWN-2
XHHW,
XHHW-2
Conductor
Size (AWG/
kcmil)
16
(12)
21
(34)
27
(1)
35
(114)
41
(112)
53
(2)
63
(212)
78
(3)
91
(312)
103
(4)
8
6
4
2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
700
750
900
1000
8
6
4
2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
700
750
900
1000
8
6
4
2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
700
750
900
1000
2
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
3
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
3
2
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
4
3
2
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
5
3
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
6
4
3
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
7
6
4
3
1
1
1
1
1
1
1
1
1
0
0
0
0
0
0
8
5
3
3
2
1
1
1
1
1
1
1
1
0
0
0
0
0
9
7
5
3
3
2
1
1
1
1
1
1
1
1
0
0
0
0
0
13
10
7
5
4
3
3
2
1
1
1
1
1
1
1
1
1
0
0
14
9
6
5
4
3
3
2
1
1
1
1
1
1
1
1
0
0
16
12
9
6
5
4
3
3
2
1
1
1
1
1
1
1
1
0
0
17
13
10
7
5
4
4
3
2
1
1
1
1
1
1
1
1
1
1
19
12
8
6
5
4
4
3
2
1
1
1
1
1
1
1
1
1
22
16
12
8
6
5
4
4
3
2
1
1
1
1
1
1
1
1
1
28
22
16
12
8
7
6
5
4
3
3
2
2
1
1
1
1
1
1
32
20
14
10
9
7
6
5
4
3
3
2
2
1
1
1
1
1
37
27
20
14
10
9
7
6
5
4
3
3
3
2
1
1
1
1
1
40
31
23
17
12
10
9
7
6
5
4
4
3
3
2
1
1
1
1
45
28
20
15
13
10
9
7
6
5
4
4
3
2
2
1
2
1
52
38
28
20
15
13
11
9
7
6
5
4
4
3
2
2
1
2
1
62
48
36
26
18
16
13
11
9
7
6
6
5
4
3
3
3
2
2
70
43
31
23
20
16
14
11
9
7
7
6
5
4
3
3
3
2
80
59
43
31
23
20
17
14
11
9
8
7
6
5
4
3
3
3
2
83
64
48
35
25
21
18
15
13
10
9
8
7
6
5
4
4
3
3
93
58
41
31
26
22
18
15
12
10
9
8
7
5
5
4
3
3
107
80
58
41
31
26
22
18
15
12
10
9
8
7
5
5
4
4
3
107
82
62
45
32
27
23
20
16
13
11
10
9
8
6
5
5
4
4
120
74
53
40
34
28
24
19
15
13
11
10
9
7
6
6
5
4
138
103
74
53
40
34
29
24
20
16
13
12
11
9
7
6
6
5
4
Definition: Compact stranding is the result of a manufacturing process where the standard conductor is
compressed to the extent that interstices (voids between strand wires) are virtually eliminated.
1372
2011
Informative Annex C
Conduit and Tubing Fill Tables for Conductors and Fixture Wires of the Same Size
Type
RHH, RHW,
RHW-2
TW
RHH, RHW,
RHW-2 , THHW,
THW, THW-2
RHH , RHW ,
RHW-2 , THHW,
THW
RHH , RHW ,
RHW-2 , THHW,
THW, THW-2
RHH, RHW,
RHW-2, TW,
THW, THHW,
THW-2
Conductor
Size (AWG/
kcmil)
12
(38)
16
(12)
21
(34)
27
(1)
35
(114)
41
(112)
53
(2)
14
12
10
8
6
4
3
2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
700
750
800
900
1000
1250
1500
1750
2000
14
12
10
8
2
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
5
4
3
1
4
3
3
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
9
7
5
3
7
6
5
2
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
15
12
9
5
12
10
8
4
3
2
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
25
19
14
8
21
17
14
7
6
4
4
3
1
1
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
44
33
25
14
27
22
18
9
7
6
5
4
3
2
1
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
57
43
32
18
844
36
29
15
12
9
8
7
5
4
3
3
2
1
1
1
1
1
1
1
1
1
1
1
0
0
0
0
93
71
53
29
14
10
16
29
38
62
12
10
3
1
5
3
8
6
13
10
23
18
30
23
50
39
11
14
23
11
18
13
11
(Continues)
2011
1373
Informative Annex C
Conduit and Tubing Fill Tables for Conductors and Fixture Wires of the Same Size
Type
RHH , RHW ,
RHW-2 , TW,
THW, THHW,
THW-2
THHN, THWN,
THWN-2
1374
Conductor
Size (AWG/
kcmil)
12
(38)
16
(12)
21
(34)
27
(1)
35
(114)
41
(112)
53
(2)
2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
700
750
800
900
1000
1250
1500
1750
2000
14
12
10
8
6
4
3
2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
700
750
800
900
1000
14
12
10
8
6
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
8
5
3
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
7
5
4
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
13
9
6
3
2
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
12
9
6
3
2
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
22
16
10
6
4
2
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
21
15
11
6
4
2
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
36
26
16
9
7
4
3
3
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
35
25
18
10
7
4
3
2
2
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
63
46
29
16
12
7
6
5
4
3
2
1
1
1
1
1
1
1
1
1
0
0
0
0
61
44
32
18
13
6
4
3
3
2
1
1
1
1
1
1
1
1
1
1
0
0
0
0
0
0
81
59
37
21
15
9
8
7
5
4
3
3
2
1
1
1
1
1
1
1
1
1
1
0
79
57
41
23
17
9
7
6
5
4
3
3
2
1
1
1
1
1
1
1
1
1
1
0
0
0
133
97
61
35
25
15
13
11
8
7
6
5
4
3
3
2
1
1
1
1
1
1
1
1
129
94
68
39
27
2011
Informative Annex C
Conduit and Tubing Fill Tables for Conductors and Fixture Wires of the Same Size
16
(12)
21
(34)
27
(1)
35
(114)
41
(112)
53
(2)
4
3
2
1
1
1
1
1
1
3
2
1
5
4
3
9
7
6
12
10
8
19
16
13
1
1/0
2/0
3/0
4/0
0
0
0
0
0
1
1
1
0
0
1
1
1
1
1
2
1
1
1
1
4
3
3
2
1
5
4
4
3
2
9
7
6
5
4
14
12
10
8
6
4
3
2
1
9
6
4
2
1
1
1
0
0
15
10
6
4
3
1
1
1
1
26
18
11
7
5
3
2
1
1
42
30
18
11
8
5
4
3
2
73
52
32
20
14
9
7
6
5
95
67
41
26
18
12
9
7
6
156
111
68
43
30
20
15
12
10
XHH, XHHW,
XHHW-2, ZW
14
12
10
8
6
4
3
2
5
4
3
1
1
1
1
1
9
7
5
3
1
1
1
1
15
12
9
5
3
2
1
1
25
19
14
8
6
4
3
3
44
33
25
14
10
7
6
5
57
43
32
18
13
9
8
7
93
71
53
29
22
16
13
11
XHH, XHHW,
XHHW-2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
700
750
800
900
1000
1250
1500
1750
2000
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
4
3
2
1
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
5
4
3
3
2
1
1
1
1
1
1
1
1
1
1
0
0
0
0
0
8
7
6
5
4
3
3
2
1
1
1
1
1
1
1
1
1
1
0
0
Type
(Continues)
2011
1375
Informative Annex C
Conduit and Tubing Fill Tables for Conductors and Fixture Wires of the Same Size
Type
FFH-2, RFH-2
SF-2, SFF-2
SF-1, SFF-1
RFH-1, RFHH-2,
TF, TFF, XF, XFF
RFHH-2, TF, TFF,
XF, XFF
XF, XFF
TFN, TFFN
PF, PFF, PGF,
PGFF, PAF, PTF,
PTFF, PAFF
HF, HFF, ZF, ZFF,
ZHF
KF-2, KFF-2
KF-1, KFF-1
XF, XFF
Conductor
Size (AWG/
kcmil)
12
(38)
16
(12)
21
(34)
27
(1)
35
(114)
41
(112)
53
(2)
18
16
18
16
14
18
18
5
4
6
5
4
11
8
8
7
11
9
7
19
14
15
12
19
15
12
33
24
24
20
30
25
20
53
39
42
35
53
44
35
94
69
54
46
69
57
46
122
90
89
75
113
93
75
199
147
16
11
20
32
56
72
119
14
18
16
18
16
14
18
16
14
18
16
14
12
10
18
16
14
12
10
12
10
5
14
10
13
10
7
17
12
9
24
17
12
8
5
29
20
14
9
6
3
1
9
23
17
21
16
12
28
20
15
40
28
19
13
9
48
34
23
15
10
5
3
15
39
30
37
29
21
48
35
26
70
49
34
23
15
83
58
39
26
17
8
6
25
63
48
60
46
35
77
57
42
112
79
54
37
25
134
94
63
42
27
13
10
44
111
85
105
81
61
136
100
73
197
139
95
65
44
235
165
111
73
48
23
18
57
144
110
136
105
79
176
129
95
255
180
123
85
57
304
214
144
95
62
30
23
93
236
180
223
173
129
288
212
156
418
295
202
139
93
499
350
236
156
102
50
39
Notes:
1. This table is for concentric stranded conductors only. For compact stranded conductors, Table C.5(A)
should be used.
2. Two-hour fire-rated RHH cable has ceramifiable insulation which has much larger diameters than other
RHH wires. Consult manufacturers conduit fill tables.
*
Corresponds to 356.2(2).
1376
2011
Informative Annex C
Conduit and Tubing Fill Tables for Conductors and Fixture Wires of the Same Size
Type
THW, THW-2,
THHW
THHN, THWN,
THWN-2
XHHW, XHHW-2
Conductor
Size (AWG/
kcmil)
12
(38)
16
(12)
21
(34)
27
(1)
35
(114)
41
(112)
53
(2)
8
6
4
2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
700
750
900
1000
8
6
4
2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
700
750
900
1000
8
6
4
2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
700
750
900
1000
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
2
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
2
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
3
2
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
4
3
2
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
4
3
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
5
4
3
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
7
5
4
3
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
7
4
3
2
1
1
1
1
1
1
1
1
0
0
0
0
0
0
9
6
4
3
2
1
1
1
1
1
1
1
1
0
0
0
0
0
0
12
9
7
5
3
3
2
1
1
1
1
1
1
1
1
1
0
0
0
13
8
6
4
4
3
2
1
1
1
1
1
1
1
1
1
0
0
15
11
8
6
4
4
3
2
1
1
1
1
1
1
1
1
1
0
0
15
12
9
6
4
4
3
3
2
1
1
1
1
1
1
1
1
1
1
17
11
7
6
5
4
3
3
1
1
1
1
1
1
1
1
1
1
20
15
11
7
6
5
4
3
3
1
1
1
1
1
1
1
1
1
1
25
19
14
11
7
6
5
4
4
3
2
2
1
1
1
1
1
1
1
28
17
12
9
8
6
5
4
3
3
2
2
1
1
1
1
1
1
33
24
17
12
9
8
7
5
4
3
3
3
2
1
1
1
1
1
1
Corresponds to 356.2(2).
Definition: Compact stranding is the result of a manufacturing process where the standard conductor is
compressed to the extent that the interstices (voids between strand wires) are virtually eliminated.
2011
1377
Informative Annex C
Conduit and Tubing Fill Tables for Conductors and Fixture Wires of the Same Size
Type
RHH, RHW,
RHW-2
TW
RHH, RHW,
RHW-2, THHW,
THW, THW-2
RHH , RHW ,
RHW-2 , THHW,
THW
RHH , RHW ,
RHW-2 , THHW,
THW, THW-2
RHH, RHW,
RHW-2, TW, THW,
THHW, THW-2
1378
Conductor
Size (AWG/
kcmil)
12
(38)
16
(12)
21
(34)
27
(1)
35
(114)
41
(112)
53
(2)
14
12
10
8
6
4
3
2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
700
750
800
900
1000
1250
1500
1750
2000
14
12
10
8
14
2
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
5
4
3
1
3
4
3
3
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
9
7
5
3
6
7
6
5
2
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
15
12
9
5
10
11
9
8
4
3
2
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
24
19
14
8
16
20
17
13
7
5
4
4
3
1
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
43
33
24
13
28
27
23
18
9
7
6
5
4
3
2
1
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
58
44
33
18
38
45
38
30
16
13
10
8
7
5
4
4
3
3
1
1
1
1
1
1
1
1
1
1
1
0
0
0
0
96
74
55
30
64
12
10
3
1
4
3
8
6
13
10
23
18
31
24
51
40
10
14
24
6
4
3
2
1
1/0
2/0
3/0
4/0
1
1
1
0
0
0
0
0
0
1
1
1
1
1
0
0
0
0
3
1
1
1
1
1
1
1
0
4
3
3
2
1
1
1
1
1
8
6
5
4
3
2
1
1
1
11
8
7
6
4
3
3
2
1
18
13
11
10
7
6
5
4
3
2011
Informative Annex C
Conduit and Tubing Fill Tables for Conductors and Fixture Wires of the Same Size
Type
THHN, THWN,
THWN-2
Conductor
Size (AWG/
kcmil)
12
(38)
16
(12)
21
(34)
27
(1)
35
(114)
41
(112)
53
(2)
250
300
350
400
500
600
700
750
800
900
1000
1250
1500
1750
2000
14
12
10
8
6
4
3
2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
700
750
800
900
1000
14
12
10
8
6
4
3
2
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
8
5
3
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
7
5
4
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
13
9
6
3
2
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
12
9
6
3
2
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
22
16
10
6
4
2
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
21
15
11
6
4
3
2
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
35
25
16
9
6
4
3
3
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
34
25
18
10
7
5
4
3
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
62
45
28
16
12
7
6
5
4
3
2
1
1
1
1
1
1
1
1
1
0
0
0
0
60
44
31
18
13
9
7
6
1
1
1
1
1
1
1
1
1
0
0
0
0
0
0
83
60
38
22
16
9
8
7
5
4
3
3
2
1
1
1
1
1
1
1
1
1
1
0
80
59
42
24
17
12
10
8
3
2
1
1
1
1
1
1
1
1
1
1
1
0
0
137
100
63
36
26
16
13
11
8
7
6
5
4
3
3
2
1
1
1
1
1
1
1
1
133
97
70
40
28
20
16
13
9
(Continues)
2011
1379
Informative Annex C
Conduit and Tubing Fill Tables for Conductors and Fixture Wires of the Same Size
Type
Conductor
Size (AWG/
kcmil)
16
(12)
21
(34)
27
(1)
35
(114)
41
(112)
53
(2)
1/0
2/0
3/0
4/0
0
0
0
0
1
1
0
0
1
1
1
1
1
1
1
1
3
3
2
1
5
4
3
2
8
6
5
4
14
12
10
8
6
4
3
2
1
9
6
4
2
1
1
1
1
1
15
10
6
4
3
1
1
1
1
25
18
11
7
5
3
2
1
1
41
29
18
11
8
5
4
3
2
72
51
31
20
14
9
7
6
4
97
69
42
26
18
13
9
8
6
161
114
70
44
31
21
15
13
10
XHH, XHHW,
XHHW-2, ZW
14
12
10
8
6
4
3
2
5
4
3
1
1
1
1
1
9
7
5
3
1
1
1
1
15
12
9
5
3
2
1
1
24
19
14
8
5
4
3
3
43
33
24
13
10
7
6
5
58
44
33
18
13
10
8
7
96
74
55
30
22
16
14
11
XHH, XHHW,
XHHW-2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
700
750
800
900
1000
1250
1500
1750
2000
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
4
3
2
1
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
5
4
3
3
2
1
1
1
1
1
1
1
1
1
1
0
0
0
0
0
8
7
6
5
4
3
3
2
1
1
1
1
1
1
1
1
1
1
0
0
1380
2011
Informative Annex C
Conduit and Tubing Fill Tables for Conductors and Fixture Wires of the Same Size
Type
FFH-2, RFH-2,
RFHH-3
SF-2, SFF-2
SF-1, SFF-1
RFH-1, RFHH-2,
TF, TFF, XF, XFF
RFHH-2, TF, TFF,
XF, XFF
XF, XFF
TFN, TFFN
PF, PFF, PGF,
PGFF, PAF, PTF,
PTFF, PAFF
HF, HFF, ZF, ZFF,
ZHF
KF-2, KFF-2
KF-1, KFF-1
XF, XFF
Conductor
Size (AWG/
kcmil)
12
(38)
16
(12)
21
(34)
27
(1)
35
(114)
41
(114)
53
(2)
18
16
18
16
14
18
18
5
4
6
5
4
12
8
8
7
11
9
7
19
14
14
12
18
15
12
33
24
23
20
29
24
20
52
39
41
35
52
43
35
92
68
55
47
70
58
47
124
91
92
77
116
96
77
205
152
16
11
19
31
55
74
122
14
18
16
18
16
14
18
16
14
18
16
14
12
10
18
16
14
12
10
12
10
5
14
10
13
10
7
17
12
9
25
17
12
8
5
29
21
14
9
6
3
1
9
22
17
21
16
12
27
20
15
40
28
19
13
9
48
33
22
15
10
4
3
15
39
29
37
28
21
47
35
25
69
48
33
23
15
82
57
39
25
17
8
6
24
62
47
59
45
34
76
56
41
110
77
53
36
24
131
92
62
41
27
13
10
43
109
83
103
80
60
133
98
72
193
136
94
64
43
231
162
109
72
47
23
18
58
146
112
139
107
80
179
132
97
260
183
126
86
58
310
218
146
97
63
31
24
96
243
185
230
178
133
297
219
161
431
303
209
143
96
514
361
243
161
105
51
40
Notes:
1. This table is for concentric stranded conductors only. For compact stranded conductors, Table C.6(A)
should be used.
2. Two-hour fire-rated RHH cable has ceramifiable insulation which has much larger diameters than other
RHH wires. Consult manufacturers conduit fill tables.
*
Corresponds to 356.2(1).
2011
1381
Informative Annex C
Conduit and Tubing Fill Tables for Conductors and Fixture Wires of the Same Size
Type
THW, THW-2,
THHW
THHN, THWN,
THWN-2
XHHW, XHHW-2
Conductor
Size (AWG/
kcmil)
12
(38)
16
(12)
21
(34)
27
(1)
35
(114)
41
(114)
53
(2)
8
6
4
2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
700
750
900
1000
8
6
4
2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
700
750
900
1000
8
6
4
2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
700
750
900
1000
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
2
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
2
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
3
2
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
4
3
2
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
4
3
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
5
4
3
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
6
5
4
3
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
7
4
3
2
1
1
1
1
1
1
1
1
0
0
0
0
0
0
8
6
4
3
2
1
1
1
1
1
1
1
1
0
0
0
0
0
0
11
9
7
5
3
3
2
1
1
1
1
1
1
1
1
1
0
0
0
13
8
6
4
3
3
2
1
1
1
1
1
1
1
1
1
0
0
15
11
8
6
4
3
3
2
1
1
1
1
1
1
1
1
1
0
0
16
12
9
6
4
4
3
3
2
1
1
1
1
1
1
1
1
1
1
18
11
8
6
5
4
3
3
1
1
1
1
1
1
1
1
1
1
20
15
11
8
6
5
4
3
3
2
1
1
1
1
1
1
1
1
1
26
20
15
11
8
7
5
5
4
3
3
2
1
1
1
1
1
1
1
29
18
13
10
8
7
6
5
3
3
3
2
1
1
1
1
1
1
34
25
18
13
10
8
7
6
5
4
3
3
2
1
1
1
1
1
1
Corresponds to 356.2(1).
Definition: Compact stranding is the result of a manufacturing process where the standard conductor is
compressed to the extent that the interstices (voids between strand wires) are virtually eliminated.
1382
2011
Informative Annex C
Conduit and Tubing Fill Tables for Conductors and Fixture Wires of the Same Size
Type
RHH, RHW,
RHW-2
TW
RHH*, RHW*,
RHW-2*,
THHW, THW,
THW-2
RHH*, RHW*,
RHW-2*,
THHW, THW
RHH*, RHW*,
RHW-2*,
THHW, THW,
THW-2
RHH*, RHW*,
RHW-2*, TW,
THW, THHW,
THW-2
Conductor
Size (AWG/
kcmil)
21
(34)
27
(1)
35
(114)
41
(112)
53
(2)
63
(212)
78
(3)
91
(312)
103
(4)
14
12
10
8
6
4
3
2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
700
750
800
900
1000
1250
1500
1750
2000
14
12
10
8
14
4
3
3
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
9
7
5
3
6
7
6
5
2
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
15
12
9
5
10
12
10
8
4
3
2
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
25
19
14
8
16
21
17
14
7
6
4
4
3
1
1
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
44
33
25
14
29
27
22
18
9
7
6
5
4
3
2
1
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
57
43
32
18
38
44
36
29
15
12
9
8
7
5
4
3
3
2
1
1
1
1
1
1
1
1
1
1
1
0
0
0
0
93
71
53
29
62
66
55
44
23
18
14
13
11
7
6
5
4
4
3
2
2
1
1
1
1
1
1
1
1
1
1
1
0
140
108
80
44
93
102
84
68
36
28
22
19
17
11
10
8
7
6
4
4
3
3
3
2
1
1
1
1
1
1
1
1
1
215
165
123
68
143
133
110
89
46
37
29
25
22
14
13
11
9
8
6
5
5
4
4
3
3
2
2
2
1
1
1
1
1
280
215
160
89
186
173
144
116
61
48
38
33
29
19
16
14
12
10
8
7
6
6
5
4
3
3
3
3
3
1
1
1
1
365
280
209
116
243
12
13
23
30
50
75
115
149
195
10
10
18
23
39
58
89
117
152
11
14
23
35
53
70
91
6
4
3
2
1
1
1
1
1
1
3
1
1
1
1
5
3
3
2
1
8
6
5
4
3
11
8
7
6
4
18
13
11
9
7
27
20
17
14
10
41
30
26
22
15
53
40
34
29
20
70
52
44
38
26
(Continues)
2011
1383
Informative Annex C
Conduit and Tubing Fill Tables for Conductors and Fixture Wires of the Same Size
Type
THHN,
THWN,
THWN-2
FEP, FEPB,
PFA, PFAH,
TFE
1384
Conductor
Size (AWG/
kcmil)
21
(34)
27
(1)
35
(114)
1/0
2/0
3/0
4/0
0
0
0
0
1
1
1
0
1
1
1
1
2
2
1
1
250
300
350
400
500
600
700
750
800
900
1000
1250
1500
1750
2000
14
12
10
8
6
4
3
2
1
1/0
2/0
3/0
4/0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
13
9
6
3
2
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
22
16
10
6
4
2
1
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
36
26
16
9
7
4
3
3
1
1
1
1
1
250
300
350
400
500
0
0
0
0
0
0
0
0
0
0
600
700
750
800
900
1000
14
12
10
8
6
0
0
0
0
0
0
12
9
6
3
2
0
0
0
0
0
0
21
15
11
6
4
41
(112)
53
(2)
63
(212)
78
(3)
91
(312)
103
(4)
3
3
2
1
6
5
4
3
8
7
6
5
13
11
9
8
17
15
12
10
23
19
16
13
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
63
46
29
16
12
7
6
5
4
3
2
1
1
1
1
1
1
1
1
1
1
1
0
0
0
0
0
0
81
59
37
21
15
9
8
7
5
4
3
3
2
3
2
1
1
1
1
1
1
1
1
1
1
0
0
0
133
97
61
35
25
15
13
11
8
7
6
5
4
4
3
3
3
2
1
1
1
1
1
1
1
1
1
1
201
146
92
53
38
23
20
17
12
10
8
7
6
6
5
5
4
3
3
2
2
2
1
1
1
1
1
1
308
225
141
81
59
36
30
26
19
16
13
11
9
8
7
6
6
5
4
3
3
3
3
2
1
1
1
1
401
292
184
106
76
47
40
33
25
21
17
14
12
11
9
8
7
6
5
4
4
4
3
3
2
2
1
1
523
381
240
138
100
61
52
44
32
27
23
19
15
1
1
1
0
0
1
1
1
1
1
1
1
1
1
1
3
3
2
1
1
5
4
3
3
2
7
6
5
5
4
10
8
7
6
5
12
11
9
8
7
0
0
0
0
0
0
35
25
18
10
7
1
1
0
0
0
0
61
44
32
18
13
1
1
1
1
1
0
79
57
41
23
17
1
1
1
1
1
1
129
94
68
39
27
1
1
1
1
1
1
195
142
102
58
41
3
3
3
2
2
1
299
218
156
89
64
4
4
3
3
3
3
389
284
203
117
83
6
5
5
4
4
3
507
370
266
152
108
2011
Informative Annex C
Conduit and Tubing Fill Tables for Conductors and Fixture Wires of the Same Size
Type
PFA, PFAH,
TFE
PFA, PFAH,
TFE, Z
XHH, XHHW,
XHHW-2, ZW
XHH, XHHW,
XHHW-2
Conductor
Size (AWG/
kcmil)
21
(34)
27
(1)
4
3
2
1
1
1
1
1
3
2
1
1
5
4
3
2
1/0
2/0
3/0
4/0
14
12
10
8
6
4
3
2
1
14
12
10
8
6
1
1
0
0
20
14
8
5
4
2
2
1
1
9
7
5
3
1
1
1
1
1
26
18
11
7
5
3
2
1
1
15
12
9
5
3
4
3
2
1
1
1
1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
700
750
800
900
1000
1250
1500
1750
2000
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
35
(114)
41
(112)
53
(2)
63
(212)
78
(3)
91
(312)
103
(4)
9
7
6
4
12
10
8
5
19
16
13
9
29
24
20
14
44
37
30
21
58
48
40
28
75
63
52
36
1
1
1
1
42
30
18
11
8
5
4
3
2
25
19
14
8
6
3
3
2
1
73
52
32
20
14
9
7
6
5
44
33
25
14
10
4
4
3
2
95
67
41
26
18
12
9
7
6
57
43
32
18
13
7
6
5
4
156
111
68
43
30
20
15
12
10
93
71
53
29
22
11
9
8
6
235
167
102
64
45
31
23
19
15
140
108
80
44
33
18
14
12
10
360
255
156
99
69
48
35
29
23
215
165
123
68
50
23
19
16
13
469
332
203
129
90
62
45
38
30
280
215
160
89
66
30
25
20
17
611
434
266
168
118
81
59
49
40
365
280
209
116
86
2
1
1
4
3
3
7
6
5
9
8
7
16
13
11
24
20
17
36
31
26
48
40
34
62
52
44
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
4
3
2
1
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
5
4
3
3
2
1
1
1
1
1
1
1
1
1
1
0
0
0
0
0
8
7
6
5
4
3
3
2
1
1
1
1
1
1
1
1
1
1
0
0
12
10
9
7
6
5
4
3
3
2
1
1
1
1
1
1
1
1
1
1
19
16
13
11
9
7
6
5
5
4
3
3
3
2
2
1
1
1
1
1
25
21
17
14
12
10
8
7
6
5
4
4
3
3
3
3
1
1
1
1
33
28
23
19
16
13
11
10
8
7
6
5
5
4
4
3
3
2
2
2
(Continues)
2011
1385
Informative Annex C
Conduit and Tubing Fill Tables for Conductors and Fixture Wires of the Same Size
Type
FFH-2, RFH-2,
RFHH-3
SF-2, SFF-2
SF-1, SFF-1
RFH-1, RFHH-2,
TF, TFF, XF, XFF
RFHH-2, TF, TFF,
XF, XFF
XF, XFF
TFN, TFFN
PF, PFF, PGF,
PGFF, PAF, PTF,
PTFF, PAFF
HF, HFF, ZF, ZFF,
ZHF
KF-2, KFF-2
KF-1, KFF-1
XF, XFF
Conductor
Size (AWG/
kcmil)
16
(12)
21
(34)
27
(1)
35
(114)
41
(112)
53
(2)
18
16
18
16
14
18
18
8
7
11
9
7
19
14
15
12
19
15
12
33
24
24
20
30
25
20
53
39
42
35
53
44
35
94
69
54
46
69
57
46
122
90
89
75
113
93
75
199
147
16
11
20
32
56
72
119
14
18
16
18
16
14
18
16
14
18
16
14
12
10
18
16
14
12
10
12
10
9
23
17
21
16
12
28
20
15
40
28
19
13
9
48
34
23
15
10
5
3
15
39
30
37
29
21
48
35
26
70
49
34
23
15
83
58
39
26
17
8
6
25
63
48
60
46
35
77
57
42
112
79
54
37
25
134
94
63
42
27
13
10
44
111
85
105
81
61
136
100
73
197
139
95
65
44
235
165
111
73
48
23
18
57
144
110
136
105
79
176
129
95
255
180
123
85
57
304
214
144
95
62
30
23
93
236
180
223
173
129
288
212
156
418
295
202
139
93
499
350
236
156
102
50
39
Notes:
1. This table is for concentric stranded conductors only. For compact stranded conductors, Table C.7(A)
should be used.
2. Two-hour fire-rated RHH cable has ceramifiable insulation which has much larger diameters than other
RHH wires. Consult manufacturers conduit fill tables.
*
Types RHH, RHW, and RHW-2 without outer covering.
1386
2011
Informative Annex C
Conduit and Tubing Fill Tables for Conductors and Fixture Wires of the Same Size
Type
THW, THW-2,
THHW
THHN,
THWN,
THWN-2
XHHW,
XHHW-2
Conductor
Size (AWG/
kcmil)
8
6
4
2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
700
750
900
1000
8
6
4
2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
700
750
900
1000
8
6
4
2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
700
750
900
1000
27
(1)
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
7
5
4
3
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
7
4
3
2
1
1
1
1
1
1
1
1
0
0
0
0
0
0
9
6
4
3
2
1
1
1
1
1
1
1
1
0
0
0
0
0
0
2
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
2
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
3
2
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
4
3
2
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
4
3
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
5
4
3
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
35
41
(114) (112)
12
9
7
5
3
3
2
1
1
1
1
1
1
1
1
1
0
0
0
13
8
6
4
4
3
2
1
1
1
1
1
1
1
1
1
0
0
15
11
8
6
4
4
3
2
1
1
1
1
1
1
1
1
1
0
0
15
12
9
6
4
4
3
3
2
1
1
1
1
1
1
1
1
1
1
17
11
7
6
5
4
3
3
1
1
1
1
1
1
1
1
1
1
20
15
11
7
6
5
4
3
3
1
1
1
1
1
1
1
1
1
1
53
(2)
63
(212)
78
(3)
25
19
14
11
7
6
5
4
4
3
2
2
1
1
1
1
1
1
1
28
17
12
9
8
6
5
4
3
3
2
2
1
1
1
1
1
1
33
24
17
12
9
8
7
5
4
3
3
3
2
1
1
1
1
1
1
38
29
22
16
11
10
8
7
6
4
4
3
3
3
1
1
1
1
1
43
26
19
14
12
10
8
7
5
4
4
3
3
2
1
1
1
1
49
37
26
19
14
12
10
8
7
5
5
4
4
3
2
1
1
2
1
58
45
34
25
17
15
13
11
9
7
6
5
5
4
3
3
3
2
1
66
41
29
22
19
15
13
10
8
7
6
5
5
4
3
3
2
2
76
56
41
29
22
19
16
13
11
8
7
6
6
5
4
3
3
2
2
91 103
(312) (4)
76
59
44
32
23
20
16
14
12
9
8
7
6
5
4
4
3
3
3
86
53
38
28
24
20
17
14
11
9
8
7
6
5
4
4
3
3
98
73
53
38
28
24
20
17
14
11
9
8
7
6
5
4
4
3
3
99
77
57
42
30
26
21
18
15
12
10
9
8
7
6
5
5
4
4
112
69
50
37
32
26
22
18
14
12
11
9
8
6
6
5
4
4
129
95
69
50
37
32
27
22
18
15
12
11
10
8
6
6
5
4
4
Definition: Compact stranding is the result of a manufacturing process where the standard conductor is
compressed to the extent that the interstices (voids between strand wires) are virtually eliminated.
2011
1387
Informative Annex C
Conduit and Tubing Fill Tables for Conductors and Fixture Wires of the Same Size
TABLE C.8 Maximum Number of Conductors or Fixture Wires in Rigid Metal Conduit
(RMC) (Based on Table 1, Chapter 9)
CONDUCTORS
Type
RHH, RHW,
RHW-2
TW
RHH*, RHW*,
RHW-2*
THHW, THW,
THW-2
RHH*, RHW*,
RHW-2*,
THHW, THW
RHH*, RHW*,
RHW-2*,
THHW, THW,
THW-2
RHH*, RHW*,
RHW-2*, TW,
THW, THHW,
THW-2
1388
Conductor
Size (AWG/ 16 21 27
(12) (34) (1)
kcmil)
53
63
78
91 103 129
(2) (212) (3) (312) (4) (5)
155
(6)
276
229
185
97
77
60
53
46
30
26
23
20
17
13
11
10
9
8
6
6
5
5
5
4
3
3
2
2
581
446
332
185
387
398
330
267
139
112
87
76
66
44
38
33
28
24
18
16
15
13
11
9
8
8
7
7
6
5
4
4
3
839
644
480
267
558
14
12
10
8
6
4
3
2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
700
750
800
900
1000
1250
1500
1750
2000
14
12
10
8
14
4
3
3
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
9
7
5
3
6
7
6
5
2
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
15
12
9
5
10
12
10
8
4
3
2
2
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
25
19
14
8
17
21
17
14
7
6
4
4
3
1
1
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
44
33
25
14
29
28
23
19
10
8
6
5
4
3
2
2
1
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
59
45
34
19
39
46 66
38 55
31 44
16 23
13 18
10 14
9 12
7 11
5
7
4
6
4
5
3
4
3
4
1
3
1
2
1
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
0
1
0
1
0
1
0
0
98 140
75 107
56 80
31 44
65 93
102
85
68
36
29
22
19
17
11
10
8
7
6
4
4
4
3
3
2
1
1
1
1
1
1
1
1
1
216
165
123
68
143
136
113
91
48
38
30
26
23
15
13
11
10
8
6
5
5
4
4
3
3
3
2
2
1
1
1
1
1
288
221
164
91
191
176
146
118
61
49
38
34
29
19
17
14
12
11
8
7
6
6
5
4
4
3
3
3
3
1
1
1
1
370
284
212
118
246
12
13
23
32
52
75
115 154
198 311
448
10
10
18
25
41
58
90 120
154 242
350
11
15
24
35
54
72
92 145
209
6
4
3
2
1
1
1
1
1
1
3
1
1
1
1
5
3
3
2
1
8
6
5
4
3
11
8
7
6
4
18
14
12
10
7
27
20
17
14
10
41
31
26
22
15
55
41
35
30
21
71 111
53 83
45 71
38 60
27 42
160
120
103
87
61
2011
Informative Annex C
Conduit and Tubing Fill Tables for Conductors and Fixture Wires of the Same Size
Type
THHN, THWN,
THWN-2
FEP, FEPB,
PFA, PFAH,
TFE
Conductor
Size (AWG/ 16 21 27
(12) (34) (1)
kcmil)
1/0
2/0
3/0
4/0
250
300
350
400
500
600
700
750
800
900
1000
1250
1500
1750
2000
14
12
10
8
6
4
3
2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
700
750
800
900
1000
14
12
10
8
6
4
3
2
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
13
9
6
3
2
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
12
9
6
3
2
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
22
16
10
6
4
2
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
22
16
11
6
4
3
2
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
36
26
17
9
7
4
3
3
1
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
35
26
18
10
7
5
4
3
3
3
2
1
1
1
1
1
1
1
1
1
1
1
0
0
0
0
0
85
62
39
22
16
10
8
7
5
4
3
3
2
1
1
1
1
1
1
1
1
1
1
1
83
60
43
25
17
12
10
8
53
63
78
91 103 129
(2) (212) (3) (312) (4) (5)
6
5
4
3
3
2
1
1
1
1
1
1
1
1
1
1
1
0
0
140
102
64
37
27
16
14
11
8
7
6
5
4
3
3
2
2
1
1
1
1
1
1
1
136
99
71
41
29
20
17
14
8
7
6
5
4
3
3
3
2
1
1
1
1
1
1
1
1
1
1
200
146
92
53
38
23
20
17
12
10
8
7
6
5
4
3
3
2
1
1
1
1
1
1
194
142
102
58
41
29
24
20
13
11
9
8
6
5
5
4
3
3
2
2
2
1
1
1
1
1
1
309
225
142
82
59
36
31
26
19
16
13
11
9
7
6
5
5
4
3
3
3
2
2
1
300
219
157
90
64
44
37
31
18
15
13
10
8
7
6
6
5
4
3
3
3
3
2
1
1
1
1
412
301
189
109
79
48
41
34
25
21
18
15
12
10
8
7
7
5
4
4
4
3
3
3
400
292
209
120
85
59
50
41
23
19
16
14
11
9
8
7
6
5
4
4
4
4
3
2
2
1
1
531
387
244
140
101
62
53
44
33
27
23
19
16
13
11
10
8
7
6
5
5
4
4
4
515
376
269
154
110
77
64
53
155
(6)
36
52
31
44
26
37
21
31
17
25
15
22
13
19
12
17
10
14
8
12
7
10
7
10
6
9
6
8
5
8
4
6
3
5
3
4
3
4
833 1202
608 877
383 552
221 318
159 230
98 141
83 120
70 100
51
74
43
63
36
52
30
43
25
36
20
29
17
25
15
22
13
20
11
16
9
13
8
11
7
11
7
10
6
9
6
8
808 1166
590 851
423 610
242 350
172 249
120 174
100 145
83 120
(Continues)
2011
1389
Informative Annex C
Conduit and Tubing Fill Tables for Conductors and Fixture Wires of the Same Size
Type
PFA, PFAH,
TFE
PFA, PFAH,
TFE, Z
XHH, XHHW,
XHHW-2, ZW
XHH, XHHW,
XHHW-2
1390
Conductor
Size (AWG/ 16 21 27
(12) (34) (1)
kcmil)
53
63
78
91 103 129
(2) (212) (3) (312) (4) (5)
14
21
28
37
1/0
2/0
3/0
4/0
14
12
10
8
6
4
3
2
1
14
12
10
8
6
4
3
2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
700
750
800
900
1000
1250
1500
1750
2000
1
1
0
0
15
10
6
4
3
1
1
1
1
9
7
5
3
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
26
18
11
7
5
3
2
1
1
15
12
9
5
3
2
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
42
30
18
11
8
5
4
3
2
25
19
14
8
6
4
3
3
1
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
3
3
2
1
73
52
32
20
14
9
7
6
5
44
33
25
14
10
7
6
5
4
3
2
1
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
5
4
3
2
100
71
43
27
19
13
9
8
6
59
45
34
19
14
10
8
7
5
4
3
3
2
1
1
1
1
1
1
1
1
1
1
1
0
0
0
0
8
6
5
4
164
116
71
45
31
22
16
13
10
98
75
56
31
23
16
14
12
9
7
6
5
4
3
3
2
2
1
1
1
1
1
1
1
1
1
0
0
11
9
8
6
234
166
102
64
45
31
22
19
15
140
107
80
44
33
24
20
17
12
10
9
7
6
5
4
3
3
2
1
1
1
1
1
1
1
1
1
1
18
14
12
10
361
256
157
99
69
48
35
29
23
216
165
123
68
51
37
31
26
19
16
13
11
9
7
6
6
5
4
3
3
3
2
2
1
1
1
1
1
24
19
16
13
482
342
209
132
93
64
47
39
31
288
221
164
91
68
49
41
35
26
22
18
15
12
10
9
7
7
5
4
4
4
3
3
3
2
1
1
1
30
25
21
17
621
440
269
170
120
82
60
50
40
370
284
212
118
87
63
53
45
33
28
23
19
16
13
11
10
9
7
6
5
5
4
4
4
3
2
1
1
57
155
(6)
83
48
69
40
57
33
47
27
39
974 1405
691 997
423 610
267 386
188 271
129 186
94 136
78 113
63
92
581 839
446 644
332 480
185 267
137 197
99 143
84 121
70 101
52
76
44
64
37
53
30
44
25
36
20
30
18
25
15
22
14
20
11
16
9
13
8
11
7
11
7
10
6
9
6
8
4
6
4
5
3
5
3
4
2011
Informative Annex C
Conduit and Tubing Fill Tables for Conductors and Fixture Wires of the Same Size
Type
FFH-2, RFH-2,
RFHH-3
SF-2, SFF-2
SF-1, SFF-1
RFH-1, RFHH-2,
TF, TFF, XF, XFF
RFHH-2, TF, TFF,
XF, XFF
XF, XFF
TFN, TFFN
PF, PFF, PGF,
PGFF, PAF, PTF,
PTFF, PAFF
HF, HFF, ZF, ZFF,
ZHF
KF-2, KFF-2
KF-1, KFF-1
XF, XFF
Conductor
Size (AWG/
kcmil)
16
(12)
21
(34)
27
(1)
35
(114)
41
(112)
53
(2)
18
16
18
16
14
18
18
8
7
11
9
7
19
14
15
12
19
15
12
33
25
24
20
31
25
20
54
40
42
35
53
44
35
94
69
57
48
72
59
48
127
94
94
79
118
98
79
209
155
16
11
20
32
56
76
125
14
18
16
18
16
14
18
16
14
18
16
14
12
10
18
16
14
12
10
12
10
9
23
17
21
16
12
28
20
15
40
28
19
13
9
48
34
23
15
10
5
3
15
40
30
38
29
22
48
36
26
71
50
34
23
15
84
59
40
26
17
8
6
25
64
49
61
47
35
79
58
42
114
80
55
38
25
136
96
64
42
28
13
10
44
111
84
105
81
61
135
100
73
197
138
95
65
44
235
165
111
73
48
23
18
59
150
115
143
110
83
184
136
100
267
188
129
89
59
318
224
150
100
65
32
25
98
248
189
235
181
136
303
223
164
439
310
213
146
98
524
368
248
164
107
52
41
Notes:
1. This table is for concentric stranded conductors only. For compact stranded conductors, Table C.8(A)
should be used.
2. Two-hour fire-rated RHH cable has ceramifiable insulation which has much larger diameters than other
RHH wires. Consult manufacturers conduit fill tables.
*Types RHH, RHW, and RHW-2 without outer covering.
2011
1391
Informative Annex C
Conduit and Tubing Fill Tables for Conductors and Fixture Wires of the Same Size
TABLE C.8(A) Maximum Number of Compact Conductors in Rigid Metal Conduit (RMC)
(Based on Table 1, Chapter 9)
COMPACT CONDUCTORS
Type
THW, THW-2,
THHW
THHN,
THWN,
THWN-2
XHHW,
XHHW-2
Conductor
Size (AWG/ 16 21 27
(12) (34) (1)
kcmil)
8
6
4
2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
700
750
900
1000
8
6
4
2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
700
750
900
1000
8
6
4
2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
700
750
900
1000
2
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
2
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
3
2
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
4
3
2
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
5
3
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
5
4
3
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
7
5
4
3
1
1
1
1
1
1
1
1
1
0
0
0
0
0
0
8
5
3
2
1
1
1
1
1
1
1
1
0
0
0
0
0
0
9
6
5
3
2
1
1
1
1
1
1
1
1
0
0
0
0
0
0
13
8
6
4
4
3
2
1
1
1
1
1
1
1
1
1
0
0
15
11
8
6
4
4
3
2
1
1
1
1
1
1
1
1
1
0
0
16
12
9
7
5
4
3
3
2
1
1
1
1
1
1
1
1
1
1
18
11
8
6
5
4
3
3
2
1
1
1
1
1
1
1
1
1
21
15
11
8
6
5
4
3
3
2
1
1
1
1
1
1
1
1
1
53
63
78
91 103 129
(2) (212) (3) (312) (4) (5)
155
(6)
26
20
15
11
8
7
6
5
4
3
3
2
1
1
1
1
1
1
1
30
18
13
10
8
7
6
5
4
3
3
2
1
1
1
1
1
1
34
25
18
13
10
8
7
6
5
4
3
3
2
1
1
1
1
1
1
228
176
132
97
68
59
50
42
35
28
24
22
20
17
13
12
11
9
9
258
159
114
86
73
60
51
42
33
28
25
22
19
15
13
13
9
9
296
220
159
114
86
73
62
51
42
34
29
25
23
19
15
13
12
10
10
38
29
22
16
11
10
8
7
6
4
4
3
3
3
1
1
1
1
1
43
26
19
14
12
10
8
7
5
4
4
3
3
2
1
1
1
1
49
36
26
19
14
12
10
8
7
5
5
4
4
3
2
1
1
2
1
59
45
34
25
17
15
13
11
9
7
6
5
5
4
3
3
3
2
1
66
41
29
22
19
15
13
10
8
7
6
5
5
4
3
3
2
2
76
56
41
29
22
19
16
13
11
8
7
6
6
5
4
3
3
2
2
78
60
45
33
23
20
17
14
12
9
8
7
7
5
4
4
4
3
3
88
55
39
29
25
21
17
14
11
10
8
7
6
5
4
4
3
3
101
75
55
39
29
25
21
17
14
11
10
9
8
6
5
4
4
3
3
101
78
58
43
30
26
22
19
15
12
11
9
8
7
6
5
5
4
4
114
70
50
38
32
26
22
18
14
12
11
10
8
6
6
5
4
4
130
97
70
50
38
32
27
22
19
15
13
11
10
8
7
6
5
5
4
158
122
91
67
47
41
34
29
24
19
17
15
13
11
9
8
7
6
6
179
110
79
60
51
42
35
29
23
20
17
15
13
10
9
9
6
6
205
152
110
79
60
51
43
35
29
23
20
18
16
13
10
9
8
7
7
Definition: Compact stranding is the result of a manufacturing process where the standard conductor is
compressed to the extent that the interstices (voids between strand wires) are virtually eliminated.
1392
2011
Informative Annex C
Conduit and Tubing Fill Tables for Conductors and Fixture Wires of the Same Size
TABLE C.9 Maximum Number of Conductors or Fixture Wires in Rigid PVC Conduit,
Schedule 80 (Based on Table 1, Chapter 9)
CONDUCTORS
Type
RHH, RHW,
RHW-2
TW
RHH*, RHW*,
RHW-2*,
THHW, THW,
THW-2
RHH*, RHW*,
RHW-2*,
THHW, THW
RHH*, RHW*,
RHW-2*,
THHW, THW,
THW-2
RHH*, RHW*,
RHW-2*, TW,
THW, THHW,
THW-2
Conductor
Size (AWG/ 16 21 27
(12) (34) (1)
kcmil)
53
63
78
91 103 129
(2) (212) (3) (312) (4) (5)
14
12
10
8
6
4
3
2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
700
750
800
1000
1250
1500
1750
2000
14
12
10
8
14
3
2
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
6
5
3
1
4
5
4
3
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
11
9
6
3
8
9
7
6
3
2
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
20
15
11
6
13
17
14
11
6
4
3
3
3
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
35
27
20
11
23
23
19
15
8
6
5
4
4
2
1
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
49
38
28
15
32
39 56
32 46
26 37
13 19
11 16
8 12
7 11
6
9
4
6
3
5
3
4
3
4
2
3
1
2
1
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
0
1
0
1
0
0
0
0
82 118
63 91
47 67
26 37
55 79
12
10
19
26
44
63
10
15
20
34
12
6
4
3
2
1
1
1
1
1
0
1
1
1
1
1
3
3
2
1
1
7
5
4
3
2
9
7
6
5
3
88
73
59
31
24
19
17
14
9
8
7
6
5
4
3
3
3
2
1
1
1
1
1
1
1
1
1
185
142
106
59
123
118
98
79
41
33
26
23
20
13
11
10
8
7
5
5
4
4
3
3
2
2
2
1
1
1
1
1
250
192
143
79
166
153
127
103
54
43
33
29
25
17
15
13
11
9
7
6
5
5
4
3
3
3
3
2
1
1
1
1
324
248
185
103
215
155
(6)
243
202
163
85
68
53
47
41
27
23
20
17
15
11
10
9
8
7
6
5
5
4
4
3
2
2
1
514
394
294
163
341
349
290
234
122
98
77
67
58
38
33
29
25
21
16
14
13
12
10
8
7
7
7
5
4
4
3
3
736
565
421
234
490
99
394
49
77
307
20
29
46
62
81 128
184
16
12
10
8
6
22
17
14
12
8
35
26
22
19
13
48
35
30
26
18
62
46
39
33
23
141
105
90
77
54
98
73
63
53
37
(Continues)
2011
1393
Informative Annex C
Conduit and Tubing Fill Tables for Conductors and Fixture Wires of the Same Size
Type
THHN,
THWN,
THWN-2
FEP, FEPB,
PFA, PFAH,
TFE
1394
Conductor
Size (AWG/ 16 21 27
(12) (34) (1)
kcmil)
1/0
2/0
3/0
4/0
250
300
350
400
500
600
700
750
800
900
1000
1250
1500
1750
2000
14
12
10
8
6
4
3
2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
700
750
800
900
1000
14
12
10
8
6
4
3
2
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
9
6
4
2
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
8
6
4
2
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
17
12
7
4
3
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
16
12
8
5
3
2
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
28
20
13
7
5
3
3
2
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
27
20
14
8
6
4
3
3
3
2
1
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
70
51
32
18
13
8
7
6
4
3
3
2
1
1
1
1
1
1
1
1
1
1
0
0
68
50
36
20
14
10
8
7
53
63
78
91 103 129
(2) (212) (3) (312) (4) (5)
5
4
3
3
2
1
1
1
1
1
1
1
1
1
1
1
0
0
0
118
86
54
31
22
14
12
10
7
6
5
4
3
3
2
1
1
1
1
1
1
1
1
1
115
84
60
34
24
17
14
12
7
6
5
4
3
3
2
2
1
1
1
1
1
1
1
1
1
1
0
170
124
78
45
32
20
17
14
10
9
7
6
5
4
3
3
3
2
1
1
1
1
1
1
164
120
86
49
35
24
20
17
11
10
8
7
5
5
4
4
3
2
2
1
1
1
1
1
1
1
1
265
193
122
70
51
31
26
22
16
14
11
9
8
6
5
5
4
3
3
2
2
2
1
1
257
188
135
77
55
38
32
26
15
13
11
9
7
6
6
5
4
3
3
3
3
2
2
1
1
1
1
358
261
164
95
68
42
35
30
22
18
15
13
10
8
7
6
6
5
4
3
3
3
3
2
347
253
182
104
74
52
43
35
20
17
14
12
9
8
7
7
5
4
4
4
3
3
3
2
1
1
1
464
338
213
123
89
54
46
39
29
24
20
17
14
11
9
8
7
6
5
4
4
4
3
3
450
328
235
135
96
67
56
46
155
(6)
32
46
27
39
23
33
19
27
15
22
13
19
12
17
10
15
9
13
7
10
6
9
6
8
6
8
5
7
5
7
4
5
3
4
3
4
2
3
736 1055
537 770
338 485
195 279
141 202
86 124
73 105
61
88
45
65
38
55
32
46
26
38
22
31
18
25
15
22
13
19
12
17
10
14
8
12
7
10
7
9
6
9
6
8
5
7
714 1024
521 747
374 536
214 307
152 218
106 153
89 127
73 105
2011
Informative Annex C
Conduit and Tubing Fill Tables for Conductors and Fixture Wires of the Same Size
Type
PFA, PFAH,
TFE
PFA, PFAH,
TFE, Z
XHH, XHHW,
XHHW-2, ZW
XHH, XHHW,
XHHW-2
Conductor
Size (AWG/ 16 21 27
(12) (34) (1)
kcmil)
1/0
2/0
3/0
4/0
14
12
10
8
6
4
3
2
1
14
12
10
8
6
4
3
2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
700
750
800
900
1000
1250
1500
1750
2000
0
0
0
0
10
7
4
3
2
1
1
1
0
6
5
3
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
0
19
14
8
5
4
2
2
1
1
11
9
6
3
2
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
33
23
14
9
6
4
3
2
2
20
15
11
6
4
3
3
2
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
3
2
1
1
59
42
26
16
11
8
5
5
4
35
27
20
11
8
6
5
4
3
2
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
4
3
2
1
82
58
36
22
16
11
8
6
5
49
38
28
15
11
8
7
6
4
3
3
2
1
1
1
1
1
1
1
1
1
1
0
0
0
0
0
0
53
63
78
91 103 129
(2) (212) (3) (312) (4) (5)
8
11
18
25
32
7 10
5
8
4
6
4
5
138 198
98 141
60 86
38 54
26 38
18 26
13 19
11 16
9 13
82 118
63 91
47 67
26 37
19 28
14 20
12 17
10 14
7 10
6
9
5
7
4
6
3
5
3
4
2
3
1
3
1
3
1
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
0
1
0
1
0
1
15
12
10
8
310
220
135
85
60
41
30
25
20
185
142
106
59
43
31
26
22
16
14
11
9
8
6
5
5
4
3
3
2
2
1
1
1
1
1
1
20
17
14
11
418
297
182
115
81
55
40
33
27
250
192
143
79
59
42
36
30
22
19
16
13
11
9
7
6
6
5
4
3
3
3
3
2
1
1
1
1
27
22
18
15
542
385
235
149
104
72
52
43
35
324
248
185
103
76
55
47
39
29
24
20
17
14
11
10
8
7
6
5
4
4
4
3
3
2
1
1
1
51
155
(6)
73
42
61
35
50
29
41
24
34
860 1233
610 875
374 536
236 339
166 238
114 164
83 119
69
99
56
80
514 736
394 565
294 421
163 234
121 173
87 125
74 106
62
89
46
66
39
56
32
46
27
38
22
32
18
26
15
22
14
20
12
17
10
14
8
11
7
10
6
9
6
9
5
8
5
7
4
6
3
5
3
4
2
4
(Continues)
2011
1395
Informative Annex C
Conduit and Tubing Fill Tables for Conductors and Fixture Wires of the Same Size
Type
FFH-2, RFH-2,
RFHH-3
SF-2, SFF-2
SF-1, SFF-1
RFH-1, RFHH-2,
TF, TFF, XF, XFF
RFHH-2, TF, TFF,
XF, XFF
XF, XFF
TFN, TFFN
PF, PFF, PGF,
PGFF, PAF, PTF,
PTFF, PAFF
HF, HFF, ZF, ZFF,
ZHF
KF-2, KFF-2
KF-1, KFF-1
XF, XFF
Conductor
Size (AWG/
kcmil)
16
(12)
21
(34)
27
(1)
35
(114)
41
(112)
53
(2)
18
16
18
16
14
18
18
6
5
7
6
5
13
10
11
9
14
11
9
25
18
19
16
24
20
16
42
31
34
28
43
35
28
76
56
47
39
59
49
39
105
77
79
67
100
82
67
177
130
16
15
25
45
62
105
14
18
16
18
16
14
18
16
14
18
16
14
12
10
18
16
14
12
10
12
10
6
16
12
15
11
8
19
14
10
28
19
13
9
6
33
23
16
10
7
3
2
11
29
22
28
22
16
36
27
19
53
37
25
17
11
63
44
29
19
13
6
5
20
50
38
47
36
27
61
45
33
88
62
43
29
20
106
74
50
33
21
10
8
35
90
68
85
66
49
110
81
59
159
112
77
53
35
190
133
90
59
39
19
15
49
124
95
118
91
68
152
112
82
220
155
107
73
49
263
185
124
82
54
26
20
82
209
159
198
153
115
255
188
138
371
261
179
123
82
442
310
209
138
90
44
34
Notes:
1. This table is for concentric stranded conductors only. For compact stranded conductors, Table C.9(A)
should be used.
2. Two-hour fire-rated RHH cable has ceramifiable insulation which has much larger diameters than other
RHH wires. Consult manufacturers conduit fill tables.
*Types RHH, RHW, and RHW-2 without outer covering.
1396
2011
Informative Annex C
Conduit and Tubing Fill Tables for Conductors and Fixture Wires of the Same Size
Type
THW, THW-2,
THHW
THHN, THWN,
THWN-2
XHHW,
XHHW-2
Conductor
Size (AWG/ 16 21 27
(12) (34) (1)
kcmil)
8
6
4
2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
700
750
900
1000
8
6
4
2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
700
750
900
1000
8
6
4
2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
700
750
900
1000
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
3
2
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
3
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
4
3
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
5
4
3
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
6
3
2
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
7
5
3
2
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
11
6
5
3
3
2
1
1
1
1
1
1
1
1
0
0
0
0
12
9
6
5
3
3
2
1
1
1
1
1
1
1
1
0
0
0
0
13
10
7
5
4
3
3
2
1
1
1
1
1
1
1
1
1
0
0
15
9
6
5
4
3
3
2
1
1
1
1
1
1
1
1
0
0
17
13
9
6
5
4
3
3
2
1
1
1
1
1
1
1
1
1
0
53
63
78
91 103 129
(2) (212) (3) (312) (4) (5)
155
(6)
22
17
13
9
6
6
5
4
3
2
2
1
1
1
1
1
1
1
1
25
15
11
8
7
6
5
4
3
3
2
1
1
1
1
1
1
1
29
21
15
11
8
7
6
5
4
3
3
2
1
1
1
1
1
1
1
200
155
116
85
60
52
44
37
31
25
21
19
17
14
12
10
10
8
8
226
140
100
75
64
53
44
37
29
25
22
19
16
13
12
11
8
8
260
193
140
100
75
64
54
44
37
30
25
22
20
17
13
12
11
8
8
32
25
18
13
9
8
7
6
5
4
3
3
3
2
1
1
1
1
1
36
22
16
12
10
8
7
6
4
4
3
3
2
1
1
1
1
1
42
31
22
16
12
10
8
7
6
5
4
3
3
2
1
1
1
1
1
50
39
29
21
15
13
11
9
8
6
5
5
4
3
3
2
2
2
1
57
35
25
19
16
13
11
9
7
6
5
5
4
3
3
3
2
1
65
48
35
25
19
16
13
11
9
7
6
5
5
4
3
3
2
2
1
68
52
39
29
20
17
15
12
10
8
7
6
6
5
4
3
3
3
2
77
47
34
25
22
18
15
12
10
8
7
6
5
4
4
4
3
3
88
65
47
34
25
22
18
15
12
10
8
7
7
5
4
4
3
3
3
88
68
51
37
26
23
19
16
13
11
9
8
7
6
5
4
4
4
3
99
61
44
33
28
23
19
16
12
11
9
8
7
6
5
5
4
3
114
85
61
44
33
28
24
19
16
13
11
10
9
7
6
5
5
4
3
140
108
81
60
42
36
30
26
22
17
15
13
12
10
8
7
7
6
5
158
98
70
53
45
37
31
25
20
17
15
13
11
9
8
8
6
5
181
134
98
70
53
45
38
31
26
21
17
15
14
11
9
8
7
6
6
Definition: Compact stranding is the result of a manufacturing process where the standard conductor is
compressed to the extent that the interstices (voids between strand wires) are virtually eliminated.
2011
1397
Informative Annex C
Conduit and Tubing Fill Tables for Conductors and Fixture Wires of the Same Size
TABLE C.10 Maximum Number of Conductors or Fixture Wires in Rigid PVC Conduit,
Schedule 40 and HDPE Conduit (Based on Table 1, Chapter 9)
CONDUCTORS
Type
RHH, RHW,
RHW-2
TW
RHH*, RHW*,
RHW-2*,
THHW, THW,
THW-2
RHH*, RHW*,
RHW-2*,
THHW, THW
RHH*, RHW*,
RHW-2*,
THHW, THW,
THW-2
RHH*, RHW*,
RHW-2* TW,
THW, THHW,
THW-2
1398
Conductor
Size (AWG/ 16 21 27
(12) (34) (1)
kcmil)
53
63
78
91 103 129
(2) (212) (3) (312) (4) (5)
155
(6)
269
224
181
94
76
59
52
45
29
26
22
19
16
12
11
10
9
8
6
6
5
5
5
4
3
3
2
2
568
436
325
181
378
390
323
261
137
109
85
75
65
43
37
32
28
24
18
16
14
13
11
9
8
8
7
7
6
5
4
3
3
822
631
470
261
546
14
12
10
8
6
4
3
2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
700
750
800
900
1000
1250
1500
1750
2000
14
12
10
8
14
4
3
2
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
8
6
4
2
5
7
5
4
2
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
14
11
8
4
9
11
9
7
4
3
2
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
24
18
13
7
16
20
16
13
7
5
4
4
3
1
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
42
32
24
13
28
27
22
18
9
7
6
5
4
3
2
1
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
57
44
32
18
38
45
37
30
15
12
10
8
7
5
4
3
3
2
1
1
1
1
1
1
1
1
1
1
1
0
0
0
0
94
72
54
30
63
64
53
43
22
18
14
12
10
7
6
5
4
4
3
2
2
1
1
1
1
1
1
1
1
1
1
1
0
135
103
77
43
90
99
82
66
35
28
22
19
16
11
9
8
7
6
4
4
3
3
3
2
1
1
1
1
1
1
1
1
1
209
160
119
66
139
133
110
89
46
37
29
25
22
14
13
11
9
8
6
5
5
4
4
3
3
2
2
2
1
1
1
1
1
280
215
160
89
186
171
142
115
60
48
37
33
28
19
16
14
12
10
8
7
6
6
5
4
3
3
3
3
3
1
1
1
1
361
277
206
115
240
12
12
22
30
50
72
112 150
193 304
439
10
10
17
24
39
56
87 117
150 237
343
10
14
23
33
52
70
90 142
205
6
4
3
2
1
1
1
1
1
0
2
1
1
1
1
4
3
3
2
1
8
6
5
4
3
11
8
7
6
4
18
13
11
10
7
26
19
16
14
10
40
30
25
22
15
53
40
34
29
20
69 109
51 81
44 69
37 59
26 41
157
117
100
85
60
2011
Informative Annex C
Conduit and Tubing Fill Tables for Conductors and Fixture Wires of the Same Size
Type
THHN, THWN,
THWN-2
FEP, FEPB,
PFA, PFAH,
TFE
Conductor
Size (AWG/ 16 21 27
(12) (34) (1)
kcmil)
1/0
2/0
3/0
4/0
250
300
350
400
500
600
700
750
800
900
1000
1250
1500
1750
2000
14
12
10
8
6
4
3
2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
700
750
800
900
1000
14
12
10
8
6
4
3
2
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
11
8
5
3
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
11
8
6
3
2
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
21
15
9
5
4
2
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
20
15
10
6
4
3
2
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
34
25
15
9
6
4
3
3
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
33
24
17
10
7
5
4
3
3
3
2
1
1
1
1
1
1
1
1
1
1
0
0
0
0
0
0
82
59
37
21
15
9
8
7
5
4
3
3
2
1
1
1
1
1
1
1
1
1
1
0
79
58
41
24
17
12
10
8
53
63
78
91 103 129
(2) (212) (3) (312) (4) (5)
6
5
4
3
3
2
1
1
1
1
1
1
1
1
1
1
1
0
0
135
99
62
36
26
16
13
11
8
7
6
5
4
3
3
2
1
1
1
1
1
1
1
1
131
96
69
39
28
19
16
13
8
7
6
5
4
3
3
3
2
1
1
1
1
1
1
1
1
1
1
193
141
89
51
37
22
19
16
12
10
8
7
6
4
4
3
3
2
1
1
1
1
1
1
188
137
98
56
40
28
23
19
13
11
9
8
6
5
5
4
3
3
2
2
2
1
1
1
1
1
1
299
218
137
79
57
35
30
25
18
15
13
11
9
7
6
5
5
4
3
3
2
2
2
1
290
212
152
87
62
43
36
30
17
15
12
10
8
7
6
6
5
4
3
3
3
3
2
1
1
1
1
401
293
184
106
77
47
40
33
25
21
17
14
12
10
8
7
6
5
4
4
3
3
3
3
389
284
204
117
83
58
48
40
22
19
16
13
11
9
8
7
6
5
4
4
4
3
3
2
1
1
1
517
377
238
137
99
61
51
43
32
27
22
18
15
12
11
9
8
7
5
5
4
4
4
3
502
366
263
150
107
75
62
51
155
(6)
35
51
30
43
25
36
21
30
17
25
15
21
13
19
12
17
10
14
8
11
7
10
6
10
6
9
6
8
5
7
4
6
3
5
3
4
3
4
815 1178
594 859
374 541
216 312
156 225
96 138
81 117
68
98
50
73
42
61
35
51
29
42
24
35
20
28
17
24
15
21
13
19
11
16
9
13
8
11
7
11
7
10
6
9
6
8
790 1142
577 834
414 598
237 343
169 244
118 170
98 142
81 117
(Continues)
2011
1399
Informative Annex C
Conduit and Tubing Fill Tables for Conductors and Fixture Wires of the Same Size
Type
PFA, PFAH,
TFE
PFA, PFAH,
TFE, Z
XHH, XHHW,
XHHW-2, ZW
XHH, XHHW,
XHHW-2
1400
Conductor
Size (AWG/ 16 21 27
(12) (34) (1)
kcmil)
53
63
78
91 103 129
(2) (212) (3) (312) (4) (5)
13
20
28
36
1/0
2/0
3/0
4/0
14
12
10
8
6
4
3
2
1
14
12
10
8
6
4
3
2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
700
750
800
900
1000
1250
1500
1750
2000
1
0
0
0
13
9
6
3
2
1
1
1
1
8
6
4
2
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
24
17
10
6
4
3
2
1
1
14
11
8
4
3
2
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
40
28
17
11
7
5
4
3
2
24
18
13
7
5
4
3
3
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
3
3
2
1
70
49
30
19
13
9
6
5
4
42
32
24
13
10
7
6
5
3
3
2
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
4
4
3
2
95
68
41
26
18
12
9
7
6
57
44
32
18
13
9
8
7
5
4
3
3
2
1
1
1
1
1
1
1
1
1
1
0
0
0
0
0
8
6
5
4
158
112
69
43
30
21
15
12
10
94
72
54
30
22
16
13
11
8
7
6
5
4
3
3
2
1
1
1
1
1
1
1
1
1
1
0
0
11
9
7
6
226
160
98
62
43
30
22
18
14
135
103
77
43
32
23
19
16
12
10
8
7
6
5
4
3
3
2
1
1
1
1
1
1
1
1
1
1
17
14
12
9
350
248
152
96
67
46
34
28
23
209
160
119
66
49
35
30
25
19
16
13
11
9
7
6
5
5
4
3
3
2
2
2
1
1
1
1
1
23
19
16
13
469
333
204
129
90
62
45
38
30
280
215
160
89
66
48
40
34
25
21
17
14
12
10
8
7
6
5
4
4
3
3
3
3
1
1
1
1
30
24
20
16
605
429
263
166
116
80
58
49
39
361
277
206
115
85
61
52
44
32
27
23
19
15
13
11
9
8
7
5
5
4
4
4
3
3
2
1
1
56
155
(6)
81
47
68
39
56
32
46
26
38
952 1376
675 976
414 598
261 378
184 265
126 183
92 133
77 111
62
90
568 822
436 631
325 470
181 261
134 193
97 140
82 118
69
99
51
74
43
62
36
52
30
43
24
35
20
29
17
25
15
22
13
19
11
16
9
13
8
11
7
11
7
10
6
9
6
8
4
6
4
5
3
5
3
4
2011
Informative Annex C
Conduit and Tubing Fill Tables for Conductors and Fixture Wires of the Same Size
Type
FFH-2, RFH-2,
RFHH-3
SF-2, SFF-2
SF-1, SFF-1
RFHH-2, TF, TFF,
XF, XFF RFH-1,
RFHH-2, TF, TFF,
XF, XFF
XF, XFF
TFN, TFFN
PF, PFF, PGF,
PGFF, PAF, PTF,
PTFF, PAFF
HF, HFF, ZF, ZFF,
ZHF
KF-2, KFF-2
KF-1, KFF-1
XF, XFF
Conductor
Size (AWG/
kcmil)
16
(12)
21
(34)
27
(1)
35
(114)
41
(112)
53
(2)
18
16
18
16
14
18
18
8
6
10
8
6
17
13
14
12
17
14
12
31
23
23
19
29
24
19
51
38
40
33
50
42
33
89
66
54
46
69
57
46
122
90
90
76
114
94
76
202
149
16
10
18
30
53
73
120
14
18
16
18
16
14
18
16
14
18
16
14
12
10
18
16
14
12
10
12
10
8
20
16
19
15
11
25
18
13
36
26
17
12
8
43
30
20
13
9
4
3
14
37
28
35
27
20
45
33
24
65
46
31
22
14
78
55
37
24
16
8
6
24
60
46
57
44
33
74
54
40
107
75
52
35
24
128
90
60
40
26
12
10
42
105
80
100
77
58
129
95
70
187
132
90
62
42
223
157
105
70
45
22
17
57
144
110
137
106
79
176
130
95
256
180
124
85
57
305
214
144
95
62
30
24
94
239
183
227
175
131
292
216
158
424
299
205
141
94
506
355
239
158
103
50
39
Notes:
1. This table is for concentric stranded conductors only. For compact stranded conductors, Table C.10(A)
should be used.
2. Two-hour fire-rated RHH cable has ceramifiable insulation which has much larger diameters than other
RHH wires. Consult manufacturers conduit fill tables.
*Types RHH, RHW, and RHW-2 without outer covering.
2011
1401
Informative Annex C
Conduit and Tubing Fill Tables for Conductors and Fixture Wires of the Same Size
Type
THW, THW-2,
THHW
THHN, THWN,
THWN-2
XHHW,
XHHW-2
Conductor
Size (AWG/ 16 21 27
(12) (34) (1)
kcmil)
8
6
4
2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
700
750
900
1000
8
6
4
2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
700
750
900
1000
8
6
4
2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
700
750
900
1000
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
2
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
3
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
4
3
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
4
2
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
5
4
2
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
6
5
3
2
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
7
4
3
2
1
1
1
1
1
1
1
1
0
0
0
0
0
0
8
6
4
3
2
1
1
1
1
1
1
1
1
0
0
0
0
0
0
13
8
5
4
3
3
2
1
1
1
1
1
1
1
1
1
0
0
14
11
8
5
4
3
3
2
1
1
1
1
1
1
1
1
1
0
0
15
12
9
6
4
4
3
3
2
1
1
1
1
1
1
1
1
1
1
17
11
8
6
5
4
3
3
1
1
1
1
1
1
1
1
1
1
20
15
11
8
6
5
4
3
3
1
1
1
1
1
1
1
1
1
1
53
63
78
91 103 129
(2) (212) (3) (312) (4) (5)
155
(6)
26
20
15
11
7
6
5
5
4
3
2
2
1
1
1
1
1
1
1
29
18
13
9
8
7
5
4
3
3
3
2
1
1
1
1
1
1
33
25
18
13
9
8
7
5
5
4
3
3
2
1
1
1
1
1
1
224
173
129
95
67
58
49
42
35
27
24
21
19
16
13
12
11
9
9
253
156
112
84
72
59
50
41
32
28
24
22
18
15
13
12
9
9
290
215
156
112
84
72
60
50
42
33
28
25
22
18
15
13
12
9
9
37
28
21
15
11
9
8
7
5
4
4
3
3
2
1
1
1
1
1
41
25
18
14
12
9
8
6
5
4
4
3
3
2
1
1
1
1
47
35
25
18
14
12
10
8
7
5
4
4
3
3
2
1
1
1
1
57
44
33
24
17
15
12
10
9
7
6
5
5
4
3
3
2
2
1
64
40
28
21
18
15
12
10
8
7
6
5
4
4
3
3
2
2
73
55
40
28
21
18
15
12
10
8
7
6
5
4
4
3
3
2
2
76
59
44
32
23
20
16
14
12
9
8
7
6
5
4
4
3
3
3
86
53
38
29
24
20
17
14
11
9
8
7
6
5
4
4
3
3
99
73
53
38
29
24
20
17
14
11
9
8
7
6
5
4
4
3
3
98
76
57
42
29
25
21
18
15
12
10
9
8
7
5
5
5
4
4
111
68
49
37
31
26
22
18
14
12
10
9
8
6
5
5
4
4
127
94
68
49
37
31
26
22
18
14
12
11
10
8
6
5
5
4
4
155
119
89
66
46
40
34
29
24
19
16
15
13
11
9
8
7
6
6
175
108
77
58
49
41
34
28
22
19
17
15
13
10
9
8
6
6
200
149
108
77
58
49
42
34
29
23
19
17
15
13
10
9
8
6
6
Definition: Compact stranding is the result of a manufacturing process where the standard conductor is
compressed to the extent that the interstices (voids between strand wires) are virtually eliminated.
1402
2011
Informative Annex C
Conduit and Tubing Fill Tables for Conductors and Fixture Wires of the Same Size
TABLE C.11 Maximum Number of Conductors or Fixture Wires in Type A, Rigid PVC
Conduit (Based on Table 1, Chapter 9)
CONDUCTORS
Type
RHH, RHW,
RHW-2
TW
RHH*, RHW*,
RHW-2*,
THHW, THW,
THW-2
RHH*, RHW*,
RHW-2*,
THHW, THW
RHH*, RHW*,
RHW-2*,
THHW, THW,
THW-2
RHH*, RHW*,
RHW-2*, TW,
THHW, THW,
THW-2
Conductor
Size (AWG/
kcmil)
16
(12)
21
(34)
27
(1)
35
(114)
14
12
10
8
6
4
3
2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
700
750
800
900
1000
1250
1500
1750
2000
14
12
10
8
14
5
4
3
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
11
8
6
3
7
9
7
6
3
2
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
18
14
10
6
12
15
12
10
5
4
3
3
2
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
31
24
18
10
20
12
10
10
41
(112)
53
(2)
63
(212)
78
(3)
91
(312)
103
(4)
24
20
16
8
6
5
4
4
2
2
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
51
39
29
16
34
31
26
21
11
9
7
6
5
3
3
2
1
1
1
1
1
1
1
1
1
1
1
0
0
0
0
0
0
67
51
38
21
44
49
41
33
17
14
11
9
8
5
5
4
3
3
1
1
1
1
1
1
1
1
1
1
1
1
0
0
0
105
80
60
33
70
74
61
50
26
21
16
14
12
8
7
6
5
4
3
3
2
2
1
1
1
1
1
1
1
1
1
1
1
157
120
89
50
104
112
93
75
39
31
24
21
18
12
10
9
8
7
5
4
4
4
3
2
2
1
1
1
1
1
1
1
1
235
181
135
75
157
146
121
98
51
41
32
28
24
16
14
12
10
9
7
6
5
5
4
3
3
3
3
2
2
1
1
1
1
307
236
176
98
204
187
155
125
65
52
41
36
31
20
18
15
13
11
8
7
7
6
5
4
4
4
3
3
3
2
1
1
1
395
303
226
125
262
16
27
35
56
84
126
164
211
13
21
28
44
65
98
128
165
12
16
26
39
59
77
98
13
20
30
45
59
75
(Continues)
2011
1403
Informative Annex C
Conduit and Tubing Fill Tables for Conductors and Fixture Wires of the Same Size
Type
RHH*, RHW*,
RHW-2*, TW,
THW, THHW,
THW-2
THHN,
THWN,
THWN-2
FEP, FEPB,
PFA, PFAH,
TFE
1404
Conductor
Size (AWG/
kcmil)
16
(12)
21
(34)
27
(1)
35
(114)
4
3
2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
700
750
800
900
1000
1250
1500
1750
2000
14
12
10
8
6
4
3
2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
700
750
800
900
1000
14
12
10
8
6
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
16
11
7
4
3
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
15
11
8
4
3
2
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
27
19
12
7
5
3
2
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
26
19
13
8
5
4
4
3
1
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
44
32
20
12
8
5
4
3
2
2
1
1
1
1
1
1
1
1
0
0
0
0
0
0
43
31
22
13
9
7
6
5
3
3
2
1
1
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
73
53
33
19
14
8
7
6
4
4
3
2
1
1
1
1
1
1
1
1
1
1
0
0
70
51
37
21
15
41
(112)
53
(2)
63
(212)
78
(3)
91
(312)
103
(4)
9
8
7
5
4
3
3
2
1
1
1
1
1
1
1
1
1
1
1
0
0
0
0
96
70
44
25
18
11
9
8
6
5
4
3
3
2
1
1
1
1
1
1
1
1
1
1
93
68
48
28
20
15
13
11
7
6
5
4
4
3
2
2
1
1
1
1
1
1
1
1
1
1
0
0
150
109
69
40
28
17
15
12
9
8
6
5
4
3
3
2
2
1
1
1
1
1
1
1
146
106
76
44
31
22
19
16
11
10
8
7
6
4
4
3
3
2
1
1
1
1
1
1
1
1
1
1
225
164
103
59
43
26
22
19
14
11
10
8
6
5
4
4
3
3
2
1
1
1
1
1
218
159
114
65
46
33
29
24
17
14
12
10
9
7
6
5
5
4
3
3
3
2
2
1
1
1
1
1
338
246
155
89
64
39
33
28
21
17
14
12
10
8
7
6
5
4
3
3
3
3
2
2
327
239
171
98
70
44
37
32
22
19
16
13
11
9
8
7
6
5
4
4
3
3
3
3
1
1
1
1
441
321
202
117
84
52
44
37
27
23
19
16
13
10
9
8
7
6
5
4
4
4
3
3
427
312
224
128
91
56
48
41
29
24
21
17
14
12
10
9
8
7
5
5
4
4
4
3
3
2
1
1
566
412
260
150
108
66
56
47
35
29
24
20
17
14
12
10
9
7
6
5
5
5
4
4
549
400
287
165
117
2011
Informative Annex C
Conduit and Tubing Fill Tables for Conductors and Fixture Wires of the Same Size
Type
PFA, PFAH,
TFE
PFA, PFAH,
TFE, Z
XHH, XHHW,
XHHW-2, ZW
XHH, XHHW,
XHHW-2
Conductor
Size (AWG/
kcmil)
21
(34)
27
(1)
35
(114)
41
(112)
53
(2)
63
(212)
78
(3)
91
(312)
103
(4)
4
3
2
1
1
1
1
1
4
3
2
1
6
5
4
3
10
8
7
5
14
11
9
6
21
18
15
10
32
27
22
15
49
40
33
23
64
53
44
30
82
68
56
39
1/0
2/0
3/0
4/0
14
12
10
8
6
4
3
2
1
14
12
10
8
6
4
3
2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
700
750
800
900
1000
1250
1500
1750
2000
1
1
1
0
18
13
8
5
3
2
1
1
1
11
8
6
3
2
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
31
22
13
8
6
4
3
2
1
18
14
10
6
4
3
2
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
2
1
1
1
52
37
22
14
10
7
5
4
3
31
24
18
10
7
5
4
3
3
2
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
4
3
3
2
85
60
37
23
16
11
8
7
5
51
39
29
16
12
8
7
6
4
4
3
2
1
1
1
1
1
1
1
1
1
1
0
0
0
0
0
0
5
4
3
3
112
79
48
30
21
15
11
9
7
67
51
38
21
15
11
9
8
6
5
4
3
3
2
1
1
1
1
1
1
1
1
1
1
0
0
0
0
8
7
6
5
175
124
76
48
34
23
17
14
11
105
80
60
33
24
18
15
12
9
8
6
5
4
3
3
3
2
1
1
1
1
1
1
1
1
1
1
0
13
10
9
7
263
186
114
72
50
35
25
21
17
157
120
89
50
37
26
22
19
14
12
10
8
7
5
5
4
3
3
2
1
1
1
1
1
1
1
1
1
19
16
13
11
395
280
171
108
76
52
38
32
26
235
181
135
75
55
40
34
28
21
18
15
12
10
8
7
6
5
4
3
3
3
3
2
2
1
1
1
1
25
21
17
14
515
365
224
141
99
68
50
41
33
307
236
176
98
72
52
44
37
28
23
19
16
13
11
9
8
7
6
5
4
4
4
3
3
2
1
1
1
32
27
22
18
661
469
287
181
127
88
64
53
43
395
303
226
125
93
67
57
48
35
30
25
20
17
14
12
10
9
8
6
5
5
5
4
4
3
2
2
1
(Continues)
2011
1405
Informative Annex C
Conduit and Tubing Fill Tables for Conductors and Fixture Wires of the Same Size
Type
FFH-2, RFH-2,
RFHH-3
SF-2, SFF-2
SF-1, SFF-1
RFH-1, RFHH-2,
TF, TFF, XF, XFF
RFHH-2, TF, TFF,
XF, XFF
XF, XFF
TFN, TFFN
PF, PFF, PGF,
PGFF, PAF, PTF,
PTFF, PAFF
HF, HFF, ZF, ZFF,
ZHF
KF-2, KFF-2
KF-1, KFF-1
XF, XFF
Conductor
Size (AWG/
kcmil)
16
(12)
21
(34)
18
16
18
16
14
18
18
10
9
13
11
9
23
17
18
15
22
18
15
40
29
16
14
14
18
16
18
16
14
18
16
14
18
16
14
12
10
18
16
14
12
10
12
10
11
28
21
26
20
15
34
25
18
49
35
24
16
11
59
41
28
18
12
6
4
27
(1)
35
(114)
41
(112)
53
(2)
30
25
37
31
25
66
49
48
41
61
51
41
108
80
64
54
81
67
54
143
105
100
85
127
105
85
224
165
24
39
65
85
134
18
47
36
45
34
26
58
42
31
84
59
40
28
18
100
70
47
31
20
10
8
31
79
60
74
58
43
96
71
52
140
98
67
46
31
167
117
79
52
34
16
13
51
128
98
122
94
70
157
116
85
228
160
110
76
51
272
191
128
85
55
27
21
67
169
129
160
124
93
206
152
112
300
211
145
100
67
357
251
169
112
73
35
28
105
265
202
251
194
146
324
239
175
470
331
228
157
105
561
394
265
175
115
56
44
Notes:
1. This table is for concentric stranded conductors only. For compact stranded conductors, Table C.11(A)
should be used.
2. Two-hour fire-rated RHH cable has ceramifiable insulation which has much larger diameters than other
RHH wires. Consult manufacturers conduit fill tables.
*Types RHH, RHW, and RWH-2 without outer covering.
1406
2011
Informative Annex C
Conduit and Tubing Fill Tables for Conductors and Fixture Wires of the Same Size
Type
THW, THW-2,
THHW
THHN,
THWN,
THWN-2
XHHW,
XHHW-2
Conductor
Size (AWG/
kcmil)
16
(12)
21
(34)
27
(1)
35
(114)
41
(112)
53
(2)
63
(212)
78
(3)
91
(312)
103
(4)
8
6
4
2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
700
750
900
1000
8
6
4
2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
700
750
900
1000
8
6
4
2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
700
750
900
1000
3
2
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
3
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
4
3
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
5
4
3
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
5
3
2
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
6
5
3
2
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
8
6
5
3
2
1
1
1
1
1
1
1
1
1
0
0
0
0
0
9
6
4
3
2
1
1
1
1
1
1
1
1
0
0
0
0
0
11
8
6
4
3
2
1
1
1
1
1
1
1
1
0
0
0
0
0
14
10
8
6
4
3
3
2
1
1
1
1
1
1
1
1
1
0
0
15
9
7
5
4
3
3
2
1
1
1
1
1
1
1
1
1
0
18
13
9
7
5
4
3
3
2
1
1
1
1
1
1
1
1
1
0
18
14
10
7
5
4
4
3
3
1
1
1
1
1
1
1
1
1
1
20
12
9
7
6
5
4
3
2
1
1
1
1
1
1
1
1
1
23
17
12
9
7
6
5
4
3
2
1
1
1
1
1
1
1
1
1
28
22
16
12
8
7
6
5
4
3
3
2
2
1
1
1
1
1
1
32
20
14
10
9
7
6
5
4
3
3
2
2
1
1
1
1
1
37
27
20
14
10
9
7
6
5
4
3
3
3
2
1
1
1
1
1
42
33
24
18
13
11
9
8
6
5
4
4
3
3
2
1
1
2
1
48
30
21
16
13
11
9
8
6
5
4
4
3
3
2
2
2
1
55
41
30
21
16
13
11
9
8
6
5
5
4
3
3
2
2
2
1
64
49
37
27
19
16
14
12
10
8
7
6
5
4
3
3
3
2
2
72
45
32
24
20
17
14
11
9
8
7
6
5
4
3
3
3
2
83
62
45
32
24
20
17
14
12
9
8
7
6
5
4
3
3
3
2
84
65
48
36
25
21
18
15
13
10
9
8
7
6
5
4
4
3
3
94
58
42
31
27
22
18
15
12
10
9
8
7
5
5
4
4
3
108
80
58
42
31
27
22
18
15
12
10
9
8
7
5
5
4
4
3
107
83
62
46
32
28
23
20
17
13
11
10
9
8
6
5
5
4
4
121
75
54
40
34
28
24
19
15
13
11
10
9
7
6
6
5
4
139
103
75
54
40
34
29
24
20
16
13
12
11
9
7
6
6
5
4
Definition: Compact stranding is the result of a manufacturing process where the standard conductor is
compressed to the extent that the interstices (voids between strand wires) are virtually eliminated.
2011
1407
Informative Annex C
Conduit and Tubing Fill Tables for Conductors and Fixture Wires of the Same Size
TABLE C.12 Maximum Number of Conductors in Type EB, PVC Conduit (Based on
Table 1, Chapter 9)
CONDUCTORS
Type
RHH, RHW,
RHW-2
TW
RHH*, RHW*,
RHW-2*, THHW,
THW, THW-2
RHH*, RHW*,
RHW-2*, THHW,
THW
RHH*, RHW*,
RHW-2*, THHW,
THW, THW-2
RHH*, RHW*,
RHW-2*, TW,
THW, THHW,
THW-2
1408
Conductor
Size (AWG/
kcmil)
53
(2)
78
(3)
91
(312)
103
(4)
129
(5)
155
(6)
14
12
10
8
6
4
3
2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
700
750
800
900
1000
1250
1500
1750
2000
14
12
10
8
14
53
44
35
18
15
11
10
9
6
5
4
4
3
2
1
1
1
1
1
1
1
1
1
1
1
0
0
0
111
85
63
35
74
119
98
79
41
33
26
23
20
13
11
10
8
7
5
5
4
4
3
3
2
2
2
1
1
1
1
1
1
250
192
143
79
166
155
128
104
54
43
34
30
26
17
15
13
11
9
7
6
5
5
4
3
3
3
3
2
2
1
1
1
1
327
251
187
104
217
197
163
132
69
55
43
38
33
21
19
16
14
12
9
8
7
6
5
4
4
4
4
3
3
2
1
1
1
415
319
238
132
276
303
251
203
106
85
66
58
50
33
29
25
22
18
14
12
11
10
9
7
6
6
6
5
5
3
3
3
2
638
490
365
203
424
430
357
288
151
121
94
83
72
47
41
36
31
26
20
17
16
14
12
10
9
9
8
7
7
5
4
4
3
907
696
519
288
603
12
59
134
175
222
341
485
10
46
104
136
173
266
378
28
62
81
104
159
227
6
4
3
2
1
1/0
2/0
3/0
4/0
21
16
13
11
8
7
6
5
4
48
36
30
26
18
15
13
11
9
62
46
40
34
24
20
17
14
12
79
59
51
43
30
26
22
18
15
122
91
78
66
46
40
34
28
24
173
129
111
94
66
56
48
40
34
2011
Informative Annex C
Conduit and Tubing Fill Tables for Conductors and Fixture Wires of the Same Size
Type
THHN, THWN,
THWN-2
Conductor
Size (AWG/
kcmil)
78
(3)
91
(312)
103
(4)
129
(5)
155
(6)
250
300
350
400
500
600
700
750
800
900
1000
1250
1500
1750
2000
3
3
2
2
1
1
1
1
1
1
1
1
1
1
0
7
6
6
5
4
3
3
3
3
2
2
1
1
1
1
10
8
7
7
5
4
4
4
3
3
3
2
1
1
1
12
11
9
8
7
6
5
5
4
4
4
3
2
2
1
19
17
15
13
11
9
8
7
7
6
6
4
4
3
3
27
24
21
19
16
13
11
11
10
9
8
6
6
5
4
14
12
10
8
6
4
3
2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
700
750
800
900
1000
159
116
73
42
30
19
16
13
10
8
7
5
4
4
3
3
2
1
1
1
1
1
1
1
359
262
165
95
68
42
36
30
22
18
15
13
10
8
7
6
6
5
4
3
3
3
3
2
468
342
215
124
89
55
46
39
29
24
20
17
14
11
10
8
7
6
5
4
4
4
3
3
595
434
274
158
114
70
59
50
37
31
26
21
18
14
12
11
10
8
6
6
5
5
4
4
915
667
420
242
175
107
91
76
57
48
40
33
27
22
19
17
15
12
10
9
8
8
7
6
1300
948
597
344
248
153
129
109
80
68
56
47
39
31
27
24
21
18
14
12
12
11
10
9
14
12
10
8
155
113
81
46
348
254
182
104
454
332
238
136
578
422
302
173
888
648
465
266
1261
920
660
378
6
4
3
2
33
23
19
16
74
52
43
36
97
68
56
46
123
86
72
59
189
132
110
91
269
188
157
129
(Continues)
2011
1409
Informative Annex C
Conduit and Tubing Fill Tables for Conductors and Fixture Wires of the Same Size
Type
Conductor
Size (AWG/
kcmil)
78
(3)
91
(312)
103
(4)
129
(5)
155
(6)
1
1/0
2/0
3/0
4/0
11
9
7
6
5
25
20
17
14
11
32
27
22
18
15
41
34
28
23
19
63
53
43
36
29
90
75
62
51
42
14
12
10
8
6
4
3
2
1
186
132
81
51
36
24
18
15
12
419
297
182
115
81
55
40
34
27
547
388
238
150
105
72
53
44
36
696
494
302
191
134
92
67
56
45
1069
759
465
294
206
142
104
86
70
1519
1078
660
417
293
201
147
122
99
XHH, XHHW,
XHHW-2, ZW
14
12
10
8
6
4
3
2
111
85
63
35
26
19
16
13
250
192
143
79
59
42
36
30
327
251
187
104
77
56
47
39
415
319
238
132
98
71
60
50
638
490
365
203
150
109
92
77
907
696
519
288
213
155
131
110
XHH, XHHW,
XHHW-2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
700
750
800
900
1000
1250
1500
1750
2000
10
8
7
6
5
4
3
3
2
1
1
1
1
1
1
1
1
1
1
0
22
19
16
13
11
9
7
6
6
5
4
3
3
3
3
2
1
1
1
1
29
25
20
17
14
11
10
9
8
6
5
4
4
4
3
3
2
1
1
1
37
31
26
22
18
15
12
11
10
8
6
6
5
5
4
4
3
3
2
1
58
48
40
33
27
22
19
17
15
12
10
9
8
8
7
6
5
4
4
3
82
69
57
47
39
32
28
24
22
18
14
12
12
11
10
9
7
6
5
5
Notes:
1. This table is for concentric stranded conductors only. For compact stranded conductors, Table C.12(A)
should be used.
2. Two-hour fire-rated RHH cable has ceramifiable insulation which has much larger diameters than other
RHH wires. Consult manufacturers conduit fill tables.
*
Types RHH, RHW, and RHW-2 without outer covering.
1410
2011
Informative Annex C
Conduit and Tubing Fill Tables for Conductors and Fixture Wires of the Same Size
TABLE C.12(A) Maximum Number of Compact Conductors in Type EB, PVC Conduit
(Based on Table 1, Chapter 9)
COMPACT CONDUCTORS
Type
THW, THW-2,
THHW
THHN, THWN,
THWN-2
XHHW, XHHW-2
Conductor
Size (AWG/
kcmil)
53
(2)
78
(3)
91
(312)
103
(4)
129
(5)
155
(6)
8
6
4
2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
700
750
900
1000
8
6
4
2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
700
750
900
1000
8
6
4
2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
700
750
900
1000
30
23
17
13
9
8
6
5
4
3
3
3
2
1
1
1
1
1
1
34
21
15
11
9
8
6
5
4
4
3
3
2
1
1
1
1
1
39
29
21
15
11
9
8
6
5
4
4
3
3
2
1
1
1
1
1
68
52
39
29
20
17
15
12
10
8
7
6
6
5
4
3
3
3
2
77
47
34
25
22
18
15
12
10
8
7
6
5
4
4
4
3
3
88
65
47
34
25
22
18
15
12
10
8
7
7
5
4
4
3
3
3
89
69
51
38
26
23
19
16
14
11
9
8
7
6
5
4
4
4
3
100
62
44
33
28
23
20
16
13
11
9
8
7
6
5
5
4
3
115
85
62
44
33
28
24
20
16
13
11
10
9
7
6
5
5
4
4
113
87
65
48
34
29
24
21
17
14
12
11
10
8
6
6
5
5
4
128
79
57
42
36
30
25
20
16
14
12
11
9
7
6
6
5
4
146
109
79
57
42
36
30
25
21
17
14
12
11
9
7
6
6
5
5
174
134
100
74
52
45
38
32
27
21
19
17
15
12
10
9
8
7
7
196
121
87
65
56
46
38
32
25
22
19
17
14
11
10
9
7
7
225
167
121
87
65
56
47
38
32
26
22
19
17
14
11
10
9
7
7
247
191
143
105
74
64
54
46
38
30
26
24
21
18
14
13
12
10
9
279
172
124
93
79
65
55
45
35
31
27
24
20
16
14
14
10
10
320
238
172
124
93
79
67
55
46
37
31
28
25
20
16
14
13
10
10
Definition: Compact stranding is the result of a manufacturing process where the standard conductor is
compressed to the extent that the interstices (voids between strand wires) are virtually eliminated.
2011
1411