You are on page 1of 5

11/01/2016

KaimannThermalCalculationResults

Results Summary
Kaimann Thermal Calculation Suite

Data entered by: Vasco

Project ref: Vasco

Mon Jan 11 2016 11:41:27 GMT+0000 (Hora padro de GMT)

Ambient Temperature:

Line Temperature:

30

Orientation:

Horizontal

External Emissivity:

0.9

Wind Speed:

m/s

Heat Flow: W/m


Insulation cant eliminate energy loss entirely but it can reduce it dramatically. In the table below each column represents
a different insulation thickness and the cells in that column show the heat ow (energy loss) in W/m when that insulation
thickness has been applied. As the thickness increases the energy loss is reduced but the most dramatic reductions
occur when the rst few mm of insulation are applied.
Steel

Kaiex ST Class O

Pipe O.D

Pipe N.B

13

19

25

32

mm

mm

mm

mm

mm

mm

mm

mm

17.2

14

17.19

6.01

5.05

4.24

3.74

3.36

21.3

15

20.63

6.94

5.78

4.79

4.2

3.75

26.7

20

24.95

8.12

6.7

5.49

4.77

4.22

33.4

25

30.25

9.59

7.83

6.35

5.47

4.8

42.4

34

37.15

11.53

9.33

7.48

6.38

5.55

48.3

40

41.57

12.78

10.3

8.2

6.97

6.04

60.3

50

50.36

15.32

12.25

9.67

8.15

76.1

70

61.71

18.63

14.79

11.57

9.68

8.25

88.9

80

70.64

21.28

16.84

13.1

10.9

9.25

114.3

100

87.96

26.51

20.87

16.11

13.31

11.22

http://www.kaiflex.co.uk/tools/ThermalResults.htm

1/5

11/01/2016

KaimannThermalCalculationResults

141.3

125

105.97

32.03

25.12

19.29

15.86

13.29

168.3

150

123.62

37.51

29.35

22.45

18.39

15.35

219.1

200

156.16

47.76

37.27

28.37

23.13

19.19

273

250

189.81

58.55

45.62

34.62

28.13

23.25

323.9

300

221.09

68.69

53.47

40.5

32.83

27.08

355.6

350

240.9

75.03

58.37

44.17

35.77

29.46

406.4

400

271.5

85.08

66.17

50.01

40.45

33.26

457

450

301.66

95.06

73.91

55.82

45.1

37.04

508

500

331.75

105.09

81.7

61.66

49.78

40.85

610

600

391.2

125.06

97.23

73.32

59.13

48.44

660.4

641.4

419.88

134.86

104.85

79.06

63.73

52.18

711.2

692.2

449.01

144.76

112.55

84.85

68.37

55.96

762

743

510.5

154.63

120.24

90.63

73.01

59.73

812.8

793.8

544.54

164.49

127.92

96.41

77.65

63.5

863.6

844.6

578.57

174.34

135.59

102.18

82.28

67.27

914.4

895.4

612.6

184.17

143.25

107.95

86.91

71.03

1066.8

946.2

705.49

216.94

165.75

124.97

100.62

82.21

1117.6

1098.6

748.74

227.96

176.27

130.97

105.4

86.07

1498.6

1479.6

1004

304.86

235.5

176.31

141.32

115.02

1524

1505

1021.02

309.99

239.45

179.26

143.67

116.93

Surface temperatures: C
The surface temperature of insulation is different from the surface temperature of the pipe to which they are applied. As
the thickness of insulation is increased the surface temperature will become closer to the ambient temperature. In the
table below each column represents a different insulation thickness and the cells in that column show the surface
temperature when that insulation thickness has been applied.
Steel

Kaiex ST Class O

Pipe O.D

Pipe N.B

13

19

25

32

mm

mm

mm

mm

mm

mm

mm

mm

http://www.kaiflex.co.uk/tools/ThermalResults.htm

2/5

11/01/2016

KaimannThermalCalculationResults

17.2

14

30

11

9.4

8.1

7.4

6.8

21.3

15

30

11.3

9.6

8.3

7.5

6.9

26.7

20

30

11.5

9.8

8.4

7.6

7.1

33.4

25

30

11.8

10.1

8.6

7.8

7.2

42.4

34

30

12

10.3

8.8

7.3

48.3

40

30

12.1

10.4

8.9

7.4

60.3

50

30

12.4

10.6

9.1

8.2

7.5

76.1

70

30

12.6

10.8

9.3

8.3

7.7

88.9

80

30

12.7

10.9

9.4

8.4

7.7

114.3

100

30

12.9

11.1

9.5

8.6

7.9

141.3

125

30

13.1

11.3

9.7

8.7

168.3

150

29.9

13.2

11.4

9.8

8.8

8.1

219.1

200

29.9

13.4

11.5

9.9

8.9

8.2

273

250

29.9

13.5

11.7

10

9.1

8.3

323.9

300

29.9

13.6

11.8

10.1

9.1

8.4

355.6

350

30

13.7

11.8

10.2

9.2

8.4

406.4

400

30

13.8

11.9

10.2

9.2

8.4

457

450

30

13.8

12

10.3

9.3

8.5

508

500

30

13.9

12

10.3

9.3

8.5

610

600

30

14

12.1

10.4

9.4

8.6

660.4

641.4

30

14

12.1

10.4

9.4

8.6

711.2

692.2

30

14.1

12.2

10.5

9.4

8.6

762

743

30

14.1

12.2

10.5

9.5

8.7

812.8

793.8

30

14.1

12.2

10.5

9.5

8.7

863.6

844.6

30

14.2

12.3

10.6

9.5

8.7

914.4

895.4

30

14.2

12.3

10.6

9.5

8.7

1066.8

946.2

29.7

13.9

12.3

10.6

9.6

8.8

http://www.kaiflex.co.uk/tools/ThermalResults.htm

3/5

11/01/2016

KaimannThermalCalculationResults

1117.6

1098.6

30

14

12.1

10.6

9.6

8.8

1498.6

1479.6

30

14

12.1

10.5

9.5

8.7

1524

1505

30

14

12.1

10.5

9.5

8.7

Calculated -Value: W/mK


The thermal conductivity (-value) of insulation is temperature dependent and will change as the temperature changes. In
the table below each column represents a different insulation thickness and the cells in that column show the calculated
thermal conductivity when that insulation thickness has been applied (given the exact calculated temperature of the
insulation).
Steel

Kaiex ST Class O

Pipe O.D

Pipe N.B

13

19

25

32

mm

mm

mm

mm

mm

mm

mm

mm

17.2

14

0.037

0.036

0.036

0.0359

0.0359

0.0358

21.3

15

0.037

0.0361

0.036

0.0359

0.0359

0.0358

26.7

20

0.037

0.0361

0.036

0.0359

0.0359

0.0359

33.4

25

0.037

0.0361

0.036

0.0359

0.0359

0.0359

42.4

34

0.037

0.0361

0.036

0.0359

0.0359

0.0359

48.3

40

0.037

0.0361

0.036

0.0359

0.0359

0.0359

60.3

50

0.037

0.0361

0.036

0.036

0.0359

0.0359

76.1

70

0.037

0.0361

0.036

0.036

0.0359

0.0359

88.9

80

0.037

0.0361

0.036

0.036

0.0359

0.0359

114.3

100

0.037

0.0361

0.0361

0.036

0.0359

0.0359

141.3

125

0.037

0.0362

0.0361

0.036

0.0359

0.0359

168.3

150

0.037

0.0362

0.0361

0.036

0.0359

0.0359

219.1

200

0.037

0.0362

0.0361

0.036

0.0359

0.0359

273

250

0.037

0.0362

0.0361

0.036

0.036

0.0359

323.9

300

0.037

0.0362

0.0361

0.036

0.036

0.0359

355.6

350

0.037

0.0362

0.0361

0.036

0.036

0.0359

406.4

400

0.037

0.0362

0.0361

0.036

0.036

0.0359

http://www.kaiflex.co.uk/tools/ThermalResults.htm

4/5

11/01/2016

KaimannThermalCalculationResults

457

450

0.037

0.0362

0.0361

0.036

0.036

0.0359

508

500

0.037

0.0362

0.0361

0.036

0.036

0.0359

610

600

0.037

0.0362

0.0361

0.036

0.036

0.0359

660.4

641.4

0.037

0.0362

0.0361

0.036

0.036

0.0359

711.2

692.2

0.037

0.0362

0.0361

0.036

0.036

0.0359

762

743

0.037

0.0362

0.0361

0.036

0.036

0.0359

812.8

793.8

0.037

0.0362

0.0361

0.036

0.036

0.0359

863.6

844.6

0.037

0.0362

0.0361

0.036

0.036

0.0359

914.4

895.4

0.037

0.0362

0.0361

0.036

0.036

0.0359

1066.8

946.2

0.037

0.0362

0.0361

0.036

0.036

0.0359

1117.6

1098.6

0.037

0.0362

0.0361

0.036

0.036

0.0359

1498.6

1479.6

0.037

0.0362

0.0361

0.036

0.036

0.0359

1524

1505

0.037

0.0362

0.0361

0.036

0.036

0.0359

All thermal insulation calculations are made in accordance with EN ISO 12241 and other industry standard methods where applicable. These standardised
methods may not take into account all variables and are highly reliant on the quality of the variables entered. As such results should be considered indicative
only and Kaimann cannot be held liable for the use of recommendations given by this program alone.

http://www.kaiflex.co.uk/tools/ThermalResults.htm

5/5