EMC VNX Series


Replacing a disk in a 25-drive enclosure
November, 2014
This document describes how to replace a disk in an EMC VNX5300 25-drive enclosure.
Note

Do not completely remove assembly- or enclosure-level hardware from the system or rack
unless specifically directed. Figures in this procedure depict hardware completely removed
to increase their clarity.
For additional details on the locations of orderable parts, and their part number labels,
refer to the parts location guide for your specific VNX model. EMC posts and maintains
parts location guides online on the Related Documents section of https://
mydocs.emc.com/VNX. On the Related Documents page, under the VNX Hardware Parts
heading, click on the desired guide.
Topics include:
l
l
l
l

Before you begin........................................................................................................ 2


Preparing the system................................................................................................. 4
Running the Disk Replacement wizard........................................................................7
Finishing up............................................................................................................... 7

Before you begin


Before you begin this maintenance activity, refer to the component handling instructions.
You should also review the entire procedure prior to beginning any maintenance activity
on the system.

Handling replaceable units


This section describes the precautions that you must take and the general procedures
that you must follow when removing, installing, and storing any replaceable unit. The
procedures in this section apply to replaceable unit handling during hardware upgrades
as well as during general replacement.

Avoiding electrostatic discharge (ESD) damage


When replacing or installing hardware units, you can inadvertently damage the sensitive
electronic circuits in the equipment by simply touching them. Electrostatic charge that
has accumulated on your body discharges through the circuits.
Read and understand the following instructions:
l

Provide enough room to work on the equipment.

Clear the work site of any unnecessary materials or materials that naturally build up
electrostatic charge, such as foam packaging, foam cups, cellophane wrappers, and
similar items.

Do not remove replacement or upgrade units from their antistatic packaging until you
are ready to install them.

Gather the ESD kit and all other materials before servicing any units.

After servicing begins, avoid moving away from the work site; otherwise, you might
build up an electrostatic charge.

Use the ESD kit when handling any units.

If an emergency arises and the ESD kit is not available, follow the procedures in
Emergency procedures (without an ESD kit) on page 2

Use the ESD wristband that is supplied with the server.

To use it, attach the clip of the ESD wristband (strap) to any bare (unpainted) metal
on the cabinet or enclosure, and then put the wristband around your wrist with the
metal button against your skin.

Emergency procedures (without an ESD kit)


In an emergency when an ESD kit is not available, use the following procedures to reduce
the possibility of an electrostatic discharge by ensuring that your body and the
subassembly are at the same electrostatic potential.
CAUTION

These procedures are not a substitute for the use of an ESD kit. Follow them only in the
event of an emergency.

Before touching any unit, touch a bare (unpainted) metal surface of the enclosure.

Before removing any unit from its antistatic bag, place one hand firmly on a bare
metal surface of the enclosure, and at the same time, pick up the unit while it is still
sealed in the antistatic bag. Once you have done this, do not move around the room
or touch other furnishings, personnel, or surfaces until you have installed the unit

Replacing a disk in a 25-drive enclosure

When you remove a unit from the antistatic bag, avoid touching any electronic
components and circuits on it.

If you must move around the room or touch other surfaces before installing a unit,
first place the unit back in the antistatic bag. When you are ready again to install the
unit, repeat these procedures.

Removing, installing, or storing CRUs


Use the following precautions when removing, handling, or storing CRUs:
l

Do not remove a faulty CRU from the cabinet until you have the replacement
available.

Handle a CRU only when wearing an ESD wristband (strap).


n

Attach the clip of the ESD wristband to the ESD bracket or bare metal on a cabinet
enclosure.

Wrap the ESD wristband around your wrist with the metal button against your
skin.

Handle a CRU gently. A sudden jar, drop, or vibration can permanently damage some
CRUs.

Never use excessive force to remove or install a CRU. Take time to read the
instructions carefully.
CAUTION

For a module that must be installed into a slot in an enclosure, examine the rear
connectors on the module for any damage before attempting its installation.
l

Store a CRU in the antistatic bag and the specially designed shipping container in
which you received it. Use the antistatic bag and special shipping container when you
need to return the CRU.
CAUTION

A sudden jar, drop, or even a moderate vibration can permanently damage some
sensitive FRUs.
CAUTION

Some CRUs have the majority of their weight in the rear of the component. Ensure that
the back end of the CRU is supported while installing or removing it. Dropping a CRU
could result in personal injury or damage to the equipment.

Handling disks
Disks are extremely sensitive electronic components. Always handle a disk gently, and
observe the following guidelines:
l

Follow the instructions in the section on handling replaceable units in this document.

Always wear a properly attached ESD wristband when removing or replacing a disk.

Avoid touching any exposed electronic components and circuits on the disk.

Disks are sensitive to the extreme temperatures sometimes encountered during


shipping. We recommend that you leave new disks in their shipping material, and
expose the package to ambient temperature for at least four hours before attempting
to use the new disks in your storage system.
Handling disks

Do not remove a faulty disk until you have a replacement disk (with the same part
number or the part number of an approved replacement for the disk). The part
number (PN005xxxxxx) appears on the disk. A replacement disk should be the same
type (SAS, SATA, FLASH) and have the same capacity (size and speed) as the disk it is
replacing.

When removing a disk, pull the disk partially out of the slot, then wait 30 seconds for
the drive to spin down before removing it.

When installing multiple disks in a powered up system, wait at least 10 seconds


before sliding the next disk into position.

Place disks on a soft, antistatic surface, such as an industry-standard antistatic foam


pad or the container used to ship the disk. Never place a disk directly on a hard
surface.

Never hit disks, stack disks, or allow them to tip over or fall.

Summary of tasks for replacing a disk in a 25-disk enclosure


To replace a disk in a 25-drive enclosure, you must complete the tasks below in the order
in which they appear. This document provides instructions for completing each task.
1. Disabling notifications.
2. Diagnose and identify the CRU to replace.
3. Download and install the USM.
4. Run the Disk Replacement wizard, which will guide you to:
l

Open the console.

Unlock and remove the front bezel.

Remove a faulted disk.

Install a new or replacement disk.

Install and lock the front bezel.

Close the console.

5. Verify the operation of the replacement part in Unisphere.


6. Check system status.
7. Enabling notifications.
8. Return the failed part.

Preparing the system


Take the following actions to prepare the system for this maintenance activity.

Disabling Connect Home and email notifications


Use the following steps to disable Connect Home and email notification.

Replacing a disk in a 25-drive enclosure

Opening a serial connection with CS 0


Procedure
1. At the rear of the cabinet, connect the null modem cable from the serial port on the
management console to the serial port on the primary Control Station (Figure 1 on
page 5).
Figure 1 Control station serial connection

Serial port

2. Open a terminal emulation program (For example, HyperTerminal or PuTTy) and use
the following settings to create a serial connection to CS 0:
l

Bits per second: 19200

Data bits: 8

Parity: None

Stop bits: 1

Flow control: None

Emulation: Auto Detect

Telnet terminal ID: ANSI

3. Login as nasadmin.
4. Become the root user:
$ su root
Password:

Disable Connect Home and email notification


Use the open console session to disable Connect Home:
Procedure
1. As the root user, disable Connect Home:
# /nas/sbin/nas_connecthome -service stop
2. Disable the email notification service:
# /nas/bin/nas_emailuser -modify -enabled no
3. Verify that the email notification service has stopped (is not enabled):
# /nas/bin/nas_emailuser -info

Disabling Connect Home and email notifications

Results
Connect Home and email notifications are now disabled. After completing the procedure,
be sure to enable Connect Home and email notifications.

Checking the system for faulted hardware


Follow the steps below to verify the status of the system's hardware components.

Diagnosing faulted storage system hardware components


Use this procedure to log in to EMC Unisphere and check for any faulted hardware
components in the storage system.
Procedure
1. Start Unisphere for the storage system by entering the primary Control Station IP
address in a browser window.
2. In the system drop-down list on the menu bar, select the system in which you may
have a faulted hardware component.
3. Select System > Hardware > Storage Hardware.
4. Check for any faulted storage hardware components.

Running the Verify Storage System wizard


Use the Verify Storage System wizard to perform a health check on the storage system.
Procedure
1. Start the Unisphere Service Manager by doing either one of the following:
l

Click the Unisphere Service Manager icon on your desktop

Select Start > All Programs or Start > Programs, then select EMC > Unisphere
Service Manager > Unisphere Service Manager

From the System screen in Unisphere, click Launch USM in the right-hand taskbar
located under Service Tasks

2. Log in to your system.


3. From the System screen, select Diagnostics > Verify Storage System to run the storage
system health check wizard.

Replacing a disk in a 25-drive enclosure

Running the Disk Replacement wizard


CAUTION

Disk modules are extremely sensitive electronic components. Always handle a disk
module gently, and observe the following guidelines:
l

Always wear a properly attached ESD wristband when removing or replacing a disk
module.

Disk modules are sensitive to the extreme temperatures sometimes encountered


during shipping. We recommend that you leave new disk modules in their shipping
material and expose the package to ambient temperature for at least four hours
before attempting to use the new modules in your system.

When removing a disk module, pull the module part way out of the slot, then wait 30
seconds for the drive to spin down before removing it.

When installing multiple disks in a powered up system, wait at least 10 seconds


before sliding the next disk into position.

Place modules on a soft, antistatic surface, such as an industry-standard antistatic


foam pad or the container used to ship the module. Never place a disk module
directly on a hard surface.

Never hit modules, stack modules, or allow them to tip over or fall.

Avoid touching any exposed electronic components and circuits on the disk module.

Do not remove a faulty disk module until you have a replacement module (with the
same part number) or a filler module available. The part number (PN005xxxxxx)
appears on the top or bottom of the module. A replacement disk module should have
the same format (bytes per sector) and the same capacity (size and speed) as the
module it is replacing.

Procedure
1. Start the Unisphere Service Manager by doing either one of the following:
l

Click the Unisphere Service Manager icon on your desktop, or

Select Start > All Programs or Start > Programs, then select EMC > Unisphere >
Unisphere Service Manager > Unisphere Service Manager.

2. From the System screen, select Hardware > Hardware Replacement > Replace Faulted
Disk.
3. Follow the instructions that appear.

Finishing up
After completing the maintenance activity, follow the tasks in this section to return the
system to production ready.

Checking the system for faulted hardware


Follow the steps below to verify the status of the system's hardware components.

Running the Disk Replacement wizard

Checking system status


From the open terminal emulation session, view the system state:
# /nas/bin/nas_checkup
The nas_checkup command runs health checks on the File components as well as the
storage system. If the output of the nas_checkup command indicates any Errors (for
example, if a check does not pass), correct the error, following the instructions provided,
and then re-run the command before continuing.
Note

It is not required that you correct the Warnings or Information notifications at this time,
though it is recommended that these notifications be reviewed.

Running the Verify Storage System wizard


Use the Verify Storage System wizard to perform a health check on the storage system.
Procedure
1. Start the Unisphere Service Manager by doing either one of the following:
l

Click the Unisphere Service Manager icon on your desktop

Select Start > All Programs or Start > Programs, then select EMC > Unisphere
Service Manager > Unisphere Service Manager

From the System screen in Unisphere, click Launch USM in the right-hand taskbar
located under Service Tasks

2. Log in to your system.


3. From the System screen, select Diagnostics > Verify Storage System to run the storage
system health check wizard.

Verifying the operation of a new or replacement part with Unisphere


Procedure
1. Start EMC Unisphere for the storage system by entering the IP address in a browser
window.
2. In the system drop-down list on the menu bar, select the system in which you
installed or replaced the part.
3. Select System > Hardware > Storage Hardware.
4. Expand the enclosure in which you installed or replaced the part, and navigate to the
part.
5. Verify that the part is in the enclosure and that it is not faulted.

Enabling ConnectHome and email notifications


Results
Use the procedure in the section that follows to enable ConnectHome and email
notification.

Re-enable Connect Home and email notification


Use the open console session with the primary CS to re-enable Connect Home and email
notification:
8

Replacing a disk in a 25-drive enclosure

Procedure
1. As the root user, clear any existing Connect Home files and enable Connect Home:
# /nas/sbin/nas_connecthome -service start -clear
2. From the Connect Home configuration, determine the connections that are enabled:
# /nas/sbin/nas_connecthome -i
3. Verify that Connect Home works with the /nas/sbin/nas_connecthome -test
<connection_name> command for each enabled connection.
For example:
# /nas/sbin/nas_connecthome -t -email_1

or
# /nas/sbin/nas_connecthome -t -email_2

or
# /nas/sbin/nas_connecthome -t -https

or
# /nas/sbin/nas_connecthome -t -modem_1

4. Verify email notifications is configured:


# /nas/bin/nas_emailuser -info
If the Recipient Address(es) field is empty, email notifications has not been
configured and does not need to be enabled. If you want to configure email
notifications, use the /nas/bin/nas_emailuser command or Unisphere to
configure it.
If the Recipient Address(es) field is populated, email notifications was enabled. Reenable email notifications:
a. Enable email notifications:
# /nas/bin/nas_emailuser -modify -enabled yes
b. Verify that email notification works:
# /nas/bin/nas_emailuser -info
c. Test the configuration and verify that the configured Recipient Address(es)
received the test email:
# /nas/bin/nas_emailuser -test

Returning the failed part


Ship the failed part to your service provider as described in the instructions that were
included with the replacement part.

Your comments
Your suggestions will help us continue to improve the accuracy, organization, and overall
quality of the user publications.
Returning the failed part

Please send your opinion of this document to:


techpubcomments@EMC.com

10

Replacing a disk in a 25-drive enclosure

Copyright 2011-2014 EMC Corporation . All rights reserved. Published in USA.


Published November, 2014
EMC believes the information in this publication is accurate as of its publication date. The information is subject to change without
notice.
The information in this publication is provided as is. EMC Corporation makes no representations or warranties of any kind with
respect to the information in this publication, and specifically disclaims implied warranties of merchantability or fitness for a
particular purpose. Use, copying, and distribution of any EMC software described in this publication requires an applicable software
license.
EMC, EMC, and the EMC logo are registered trademarks or trademarks of EMC Corporation in the United States and other countries.
All other trademarks used herein are the property of their respective owners.
For the most up-to-date regulatory document for your product line, go to EMC Online Support (https://support.emc.com).
Returning the failed part