Professional Documents
Culture Documents
ff
Integrated energy management system with
5kW power capacity and a capacity of 4.4kWh
up to 13.2kWh
ff
Feed-in with efficiency factor of 97.7%
ff
High-performance lithium ion batteries
ff
Highly efficient DC coupling
*
The BPT-S 5 Hybrid allows flexible use of solar power by storing the surplus energy. Along with feeding
solar power into the public grid with the highest level of efficiency, it also ensures the optimum use of
self-generated power and bridge power outage events.
Integrated energy management system
grid.
used.
System
4.4 kWh
6.6 kWh
8.8 kWh
11 kWh
13.2 kWh
Input Data
Recommended DC output
5 kW
5 kW
5 kW
5 kW
5 kW
940 V
940 V
940 V
940 V
940 V
240 V
240 V
240 V
240 V
240 V
750 V
750 V
750 V
750 V
750 V
275 V
275 V
275 V
275 V
275 V
19 A
19 A
19 A
19 A
19 A
Design of connection
Number of DC inputs
MPP precision
> 99 %
> 99 %
> 99 %
> 99 %
> 99 %
230 V
230 V
230 V
230 V
230 V
22 A
22 A
22 A
22 A
22 A
5 kVA1,2
5 kVA1,2
5 kVA1,2
5 kVA1,2
5 kVA1,2
5 kVA1,2
5 kVA1,2
5 kVA1,2
5 kVA1,2
5 kVA1,2
50 Hz
50 Hz
50 Hz
50 Hz
50 Hz
51.5 Hz/47.5 Hz
51.5 Hz/47.5 Hz
51.5 Hz/47.5 Hz
51.5 Hz/47.5 Hz
51.5 Hz/47.5 Hz
Type of infeed
single-phase
single-phase
single-phase
single-phase
Design of connection
TN grid/TT grid
TN grid/TT grid
TN grid/TT grid
TN grid/TT grid
TN grid/TT grid
3%
3%
3%
3%
3%
97.7 %
97.7 %
97.7 %
97.7 %
97.7 %
90 %
90 %
90 %
90 %
90 %
94 %
94 %
94 %
94 %
94 %
Output Data
single-phase
Efficiency
Battery Data
Nominal voltage (Vdc,r)
96 V
144 V
192 V
240 V
288 V
112 V
168 V
224 V
280 V
336 V
Storage capacity
4.4 kWh
6.6 kWh
8.8 kWh
11 kWh
13.2 kWh
Battery type
DOD
50 %
50 %
50 %
50 %
50 %
2.5 kW
3.75 kW
5 kW
5 kW
5 kW
restricted4
restricted4
Yes
Yes
Yes
Nominal voltage
230 V
230 V
230 V
230 V
230 V
Nominal current
13 A
13 A
13 A
13 A
13 A
22 A
22 A
22 A
22 A
22 A
2.5 kW
3,75 kW
5 kW
5 kW
5 kW
50 Hz
50 Hz
50 Hz
50 Hz
50 Hz
24 V DC / 0.5 A
24 V DC / 0.5 A
24 V DC / 0.5 A
24 V DC / 0.5 A
24 V DC / 0.5 A
Design of connection
Type of infeed
single-phase
single-phase
single-phase
single-phase
single-phase
System
4.4 kWh
6.6 kWh
8.8 kWh
11 kWh
13.2 kWh
230 V
230 V
230 V
230 V
230 V
Stand-by supply
Nominal voltage
Nominal frequency
50 Hz
50 Hz
50 Hz
50 Hz
50 Hz
6.0 VA
6.0 VA
6.0 VA
6.0 VA
6.0 VA
Design of connection
Environmental conditions
Temperature range
-10C/+40C
-10C/+40C
-10C/+40C
-10C/+40C
-10C/+40C
+40C
+40C
+40C
+40C
+40C
070 %
070 %
070 %
070 %
070 %
2,000 m
2,000 m
2,000 m
2,000 m
2,000 m
Type of protection
IP 20
IP 20
IP 20
IP 20
IP 20
Protection class
Yes
Yes
Safety/protection equipment
Yes
Overload behaviour
Yes
Derating
Derating
Derating
Derating
Derating
Switch off
Switch off
Switch off
Switch off
Switch off
Yes
Yes
Yes
Yes
DC circuit breaker
10 sec
10 sec
Yes
Grid monitoring
Switch time to emergency power mode
10 sec
10 sec
Fulfilled requirements/clearance at
hand
Standards
Interference emission (EMV)
DIN EN 61000-6-3:2011-09
Interference-resistance (EMV)
DIN EN 61000-6-2:2006-03
System perturbation
System
Battery
CE / RCM compliant
Yes
Yes
Yes
Yes
Yes
BG test mark
Yes
Yes
Yes
Yes
Yes
transformerless
transformerless
Other
Display
Communications interfaces
Topology
transformerless
Voluntary warranties
transformerless
transformerless
Dimensions/weight
Dimensions in mm (WxHxD)
597x1,693x706
597x1,693x706
597x1,693x706
597x1,693x706
597x1,693x706
222 kg
242 kg
262 kg
280.5 kg
299 kg
Function
Morning
1
2
3
4
Afternoon
PV generator
BPT-S 5 Hybrid
Integrated storage
Allocation and counter
Night
Evening
Graphical
User
Interface
Energy
Management
System
Inverter
240 V 940 V DC
DC
DC
DC
Filter
DC
230 V AC / 50 Hz/ 1~
AC
Filter
230 V AC / 50 Hz/ 1~
DC
Battery
Management
System
DC
LI-Ion Battery
AC
Filter
AC
Battery Converter
available at
Locked Bag 66
Clayton Victoria 3169, Australia
Ph: 03-9541-7048
Fax: 03-9541-7766
Info.BoschPowerTec@au.bosch.com
www.bosch-power-tec.com
Td_Bo-BPT_S_5Hybrid-DeEnAUenItFr-1409 | Subject to technical modification without notice | 2014Bosch Power Tec GmbH
Backup Line
kWh