Learn how to measure load, pressure, and torque using a Wheatstone bridge as the guiding principle.
This document is part of the How-To Guide for Most Common Measurements centralized resource portal.
Table of Contents
Most strain gage measuring solutions provide an option to measure quarter-, half-, and full-bridge configurations.
Consider an example, shown below in Figure 1, of an NI CompactDAQ system with an NI 9237 four-channel simultaneous bridge
module.
www.ni.com
You can use MAX to quickly verify the accuracy of your measurement system setup. Using an NI-DAQmx global virtual channel,
you can configure a bridge measurement without any programming. A virtual channel is a concept of the NI-DAQmx driver
architecture used to represent a collection of device property settings that can include a name, a physical channel, input terminal
connections, the type of measurement or generation, and scaling information.
Follow these steps to begin:
1. With MAX open, select Data Neighborhood and click Create New.
2. Select NI-DAQmx Global Virtual Channel and click Next.
3. Select Acquire SignalsAnalog InputForceForce (Bridge).
www.ni.com
www.ni.com
The next step is to physically connect the sensor to your DAQ device.
9. Click the Connection Diagram tab in MAX to continue.
With NI-DAQmx global virtual channels, you can preview your measurements.
10. With MAX still open, click back on the NI-DAQmx Global Channel tab and click on the Run button. You see the value of your
measurement displayed at the top of the screen.
4/7
www.ni.com
Now that you have configured your measurement device, connected the sensor, and tested the signal, you are ready to make a
measurement using LabVIEW. Included in the attachments section are two VIs for measuring bridge-based sensors continuously.
You can find these in LabVIEW by going to HelpFind Examples... to open the NI Example Finder. The settings on the front panel
are configured in the same way that you set up the global virtual channel above.
Requirements
Bridge - Continuous Input for NI LabVIEW 2012
NI LabVIEW 2012 or Later and NI-DAQmx
5/7
www.ni.com
www.ni.com
7/7