User Manual for Inverters TEM3000A

TEM3000A
PV Off-Grid Inverter with Solar/AC Charger/MPPT

Users Manual

User Manual for Inverters TEM3000A

CONTENTS
1Safety note
2Product introduction ..................................... !
21 Overview ......................................................................... 3
2.1.1 Charging function of battery ....................................... 4
2.1.2 main features of Sine wave inverter power supply ..... 5
22 principle of operation ....................................................... 5
23 Product features .............................................................. 6
2.3.1 Product features ........................................................ 6
3. Safety and operation ................................................................. 6
31 unpacking Storage,Transportation ................................... 8
3.1.1 Unpacking.................................................................. 8
3.1.2 Storage ...................................................................... 8
3.1.3 Transportation............................................................ 8
32 Appearance and structure ............................................... 9
33 Installation and using ................................................... 11
3.3.1 Electric connection ................................................... 11
3.3.2 Operation steps ....................................................... 12
4. Contact .......................................................... !

User Manual for Inverters TEM3000A

1 SAFETY INSTRUCTIONS.
Please note below safety note to prevent being hurt or causing damage of the
product or any other related parts. Please always follow our regulation to use
our product.

1. Please read the user manual carefully, and always follow it to operate.
2. Please always choose the cables according the safety requirement &
certification of your Country, otherwise it might cause problems.
3. Please always cut the power off before you connect the input power
cables.
4. Please always cut the power off before you connect the output cables.
5. Please do not touch the input or output cables when the power is on.
6. Please do now move the devise when the power is on.
7. The system will be shut down by overheat; please do not cover heating
spread system.
8. Please keep the surface of the devise dry and clean, make sure the small
metal articles wont drop into the device.
9. 9The device is still with high voltage inside after cut off the power, please
do not open the case or touch the internal parts, it will be only safe after the
capacitance released.
10. Ground terminal must be connected to the ground,(The resistance is less
than 10),the wider the better for wire diameter, and it shall be as near as
possible to the device, as short as possible.

User Manual for Inverters TEM3000A

2, Product introduction.
2.1 Overview
This device is integrated with PV charger and Inverter, with low power
consumption display panel, Real-time display all the parameters of the PV
charge and inverter.

2.1.1 Charging function of the battery.


PV charger is using three stage charging method, in the battery voltage
detection after boot, it judges the charging mode. When the battery is over
discharged, PV charger will be automatically converted to Trickle charge
mode, after the voltage rise to 48V, it will be switched to MPPT charging. If
the battery voltage detection is >43.2V, MPPT charge will be active directly;
In the process of charging, if the voltage >57.6V, it will be converted to 56V
constant voltage charging mode, if the current of constant voltage charging
is less than 1A, it will be switched to 55.2V floating charging mode,
If the current is less than 0.6A, there will be notice on LCD screen to show
the battery is full. The charger is with below characteristics.
(1) With MPPT Solar charging function.
(2) Automatically switching in charging modes according the status of battery
(Trickle charge mode, MPPT charging mode, constant voltage charging
mode, floating charging mode)
(3) Overvoltage & undervoltage protectionThe life of the battery will be
affected by the long time charging or discharging, TEC3000 is with charging
protection function. Protective action active when <43.2V or >62V.
(4) Backflow prevention function: Charger MCU real-time monitors PV voltage
and the voltage of the battery, disconnect the PV input on time; avoid battery
current intrusion which will damage to the PV panel when the PV voltage is
lower than battery voltage.

User Manual for Inverters TEM3000A

2.1.2 main features of Sine wave inverter power supply


(1) With the high performance macrochip MCU control.
(2) With the SPWM pulse width modulation technology, output pure sine
wave with stable frequency, stable voltage, low distortion
(3) When the voltage of battery is lower than protection value, the invert
stop output, system switches to mains, after the battery recover, the
invert power supply active.
(4) The inverter automatic protects itself according to the overload value.
2.2 principle of operation
Bypass
Mains

AC Charger
AC/DC

Display

PV

PV Charger
DC/DC

DC/DC

BATTER

Pictures

DC/AC

LOAD

User Manual for Inverters TEM3000A

2.3 Product features


2.3.1 Product features
specifications

TEM3000A

Voltage of battery

48V

Pv charging parameters
Max input voltage

100V

Max input current

45A

floating charge voltage

55.2V

over charge alarm voltage

57.6V

Over discharge protection


voltage.

59.6V

MPPT tracking efficiency

99%(>50W)

MPPT tracking voltage


range

50V-88V

Maximum charging current

60A

Capacity of battery

200AH

Charging temperature
compensation

-3~7mV/ @2V

Source switching
AC transfer time

1s

AC standard

220V10%50Hz

parameter of invert circuit


Rated power

3000W

Rated output voltage

220V5%

Rated output current

13.6A

Rated frequency

50Hz0.5%

dynamic voltage transient


range

10%0-100% pure resistance load sudden changes

Instant recovery time of


Dynamic voltage

100ms when voltage recovery90%

Output current crest factor

3:1

THD(rated)

3%Pure impedance load,5%capacitive load

overload capacity

101~105% Warning without shut down(Pure impedance


load), 106~125% protects in 60S, cut-off input with
warning(Pure impedance load), 150% protects in
10s,cut-off input with warning(Pure impedance load)
151~200% protects in 10s ,cut-off input with warning(Pure
impedance load)

Surge capacity

200% Protects in 1s @25, cut-off input with


warning(Pure impedance load),

short-circuit capacity

Protects in 1ms, cut-off output with warning

User Manual for Inverters TEM3000A

connection phases

Single phase

output waveform

Pure sine wave

under-voltage protection v

43.2V

Minimum powered up v

48V

voltage of under voltage


recovery

50V

voltage of overvoltage
recovery

56V

voltage of overvoltage
protection

62V

Protection
input polarity reverse
protection

Battery under voltage


protection

Battery over-voltage
protection

overload protection

Output short circuit


protection

thermal protection

General Data
Dimension(WxHxD)

370*140*545mm

Weight

17kg

Operating temperature
range.

-10~+50derating if above 45

Quiescent current

60mA

No-load current of inverter

1A

Insulating strength

1500V 10S

Noise

50dB

Cooling concept

Intelligent air cooling

IP degree

IP43

Designed Life time

10 years.

Application
Relative humidity
range(Non-condensation)

0%~95%

Max operating altitude


above MSL

<1500m(when above 2000m derating according


GB/T3859.2 standard)

Features
Display

LCD/LED

Communication

RS485

Certification

CE

User Manual for Inverters TEM3000A

3.Installation and operation


3.1 unpacking Storage, Transportation
3.1.1

Unpacking
The device has passed strictly inspect before shipment, but it
could be damaged in transportation. So please check if all the
parts below are complete, also please check the model according
the purchase order.

Inverter TEM3000
User manual
Warranty card
Qualification
Parts related the device and other accessory according PO.
3.1.2 Storage
The storage of the device must be according below point to prevent the
harmful effect.
Device must be in a clean, dry and ventilated place.
Environment temperature between -2050
Environment humidity must be below 90%, and no condensation.
Must be away from corrosive gas or liquid
The device must be power on each six months at least to prevent the
electrolytic capacitor inside the device dried-up.

3.1.3 Transportation
The device must be avoided vibration, drop and knock; it is also strictly
prohibited to invert or incline the packing box.

User Manual for Inverters TEM3000A

3.2 Appearance and structure

Dimension of front and rear panel


LCD Display
Auxiliary power switch
RS485 port
DC input and output terminal.
AC input and output terminal

User Manual for Inverters TEM3000A

Power indicator
Charging indicator
Inverter indicator
Mains indicator
Fault indicator

PWR

CHA

INV

AC

FAU

T-SOL
ESC

ESC
Enter
Left & right
Up & down
The description of the indicatorS and buttons

User Manual for Inverters TEM3000A

3.3 Installation and using


3.3.1 Electric connection
a) Please check the case, and contact us if the case is out of shape.
b) Please check and prepare the breaker as below parts before
Wiring.
PV

Breaker 63A

Battery Breaker 125A


AC Breaker 20A

Please connect the terminal cables according below picture.


1. PV+PV-BAT+BAT- terminals set accordingly as below picture:

Note: Do not opposite the anode and cathode


2. 220V AC connects output L, N terminal, as over picture.

User Manual for Inverters TEM3000A

3.3.2 Operation steps


After connect the cables, close the breaker of PV and battery, and turn on
the power supply, the PWR lamp on, LCD screen on, after T-SOL log
apparent, it enters main interface.

CHA&INV: OFF
CHARGE : OFF
INVERT : OFF
STOP
Mode section
PV charge and inverter are working at the same time.
CHARGE

PV charger works alone.

INVERT

Inverter works alone.

Users select the work mode according to their own needs; Default option
is CHA&INV, press enter, to start work after self-checking, CHA and INV
lamps on. LCD screen shows parameter Interface. Charge and Invert
parameter display alternately.

PV VOLT72.3V
BAT VOLT54.2V
Chg Curr29.7A

Out Volt:220.4V
Out Cur : 1.1A
Frequent:50.0Hz
Loadrate:10.0%

To choose PV Charger mode, put the cursor on CHARGE, press Enter, to


start work after self-checking, CHA lamp on, LCD screen shows charging
parameter interface.
To choose invert mode, put the cursor on INVERT, press Enter, to start
work after self-checking, INV lamp on, LCD screen shows invert parameter
interface.
If there is fault in self-checking, the reason will be shown on LCD screen,

User Manual for Inverters TEM3000A

but wont affect the work of other part, example: self-checking PV voltage is
low, charger stop working, stand by; inverter part is ok, then only the
inverter starts, after PV voltage is right, the charger will be started again.

Mode switching,
Users press ESC button to switch to other mode when the devise is on, put
the cursor on target mode, press enter, the device switches to target mode.
1Shut down: press ESC button, return to last menu, put cursor on
STOP, press

, device stop working, and then cut down the

power.
5Fault indicator : Its on when the device has fault.
(Note: detail menu please refer to accessory )
4.

Contact

Ten Sources Solar Electricity Limited has new information about the products and new
model, please check the website.
Ten Sources Solar Electricity Limited
HQ: Room 10-11, 6/F, Kwong Sang Hong Centre, 151-153 Hoi Bun Road, Kwun Tong,
Kowloon, Hong Kong
Tel: 852-2790 5566
Fax: 852-2342 0146
http://www.tsolpv.com
Huizhou Ten Sources Solar Electricity Limited
Address: Dongjiang Industrial Estate, Shuikou Street, Huizhou City, Guangdong, China
Tel: 86-752-2312 888
Fax: 86-752-2313 888
Post code: 516005
Email: tsolmkt@tenpao.com

Note: This sample device has no other accessory; we are looking forward to
your feedback, it helps us to improve our performance and quality.