You are on page 1of 5

CARD IN RNC 2600

(A)

RSMU :- (2N) RESOURCE & SWITCH MANAGEMENT UNIT

1) CONTROLS THE SWITCH FABRICS IN RNC


2) ESTABLISH CONNECTION FOR CALL ACCORDING TO REQUEST FROM SIGNALLING
3) HANDLE DSP RESOURCE MANAGEMENT
4) ATM SWITCHING MANAGENENT FUNCTION
5) ESTABLISH OF BOTH INTERNAL & EXTERNAL CONNECTION VIA SFU
(B)

ICSU :-(N+1) INTERFACE CONTROL & SIGNALLING UNIT

1) SIGNALLING TO OTHER NETWORK ELEMENT & DISTRIBUTED RADIO RESOURCE


2) HANDLES SIGNALLING TRANSACTION & RRM FUNCTION
3) MONITORING & RECOVERY OF SIGNALLING LINK
4) DISTRIBUTED RRM FUNCATIONS
(C)

DMCU :- (SN+) DATA MICRODIVERCITY COMBINING UNIT

1) GTP TERMINATION (GPRS TUNNILING PROTOCOL)


2) PDCP PROTOCOL PROCESSING( PACKET DATA CONVERENCE PROTOCOL)
2) MAC-C & MAC-D PROTOCOL PROCESSING
(D)

NPS1 :- (NONE OR 2 N) NETWORK PROCESSOR INTERFACE UNIT STM-1

1) TRANSLATS ATM HEADER


2) PERFORM AAL2 MINIPACKET SWITCHING
3) MAPS ATM CELLS TO/ FROM TRANSMISSION FRAME STRUCTURE OF SDH/SONET
(E) NPGE :-(NONE OR 2N) NETWORK PROCESSOR INTERFACE UNIT GIGABIT
ETHERNET
1) TRANSLATE IP HEADER
2) MAP IP PACKET TO /FROM TRANSMISSION FRAME STRUCTURE OF ETHERNET
3)PROVIDE ETHERNET INTERFACE & HANDLES MUTIPROTOCOL PACKET PROCESSING AT
WIRE SPEED
(F) SFU :- (2N) SWITCHINGFABRIC UNIT
1) PROVIDES A PART OF THE CELL SWITCHING FUNCTION

2) CONNECT NETWORK INTERFACE TO MXU


(G)

MXU :- (2N) MULTIPLEXING UNIT

1) CONNECT NETWORK INTERFACE UNIT,SIGNALLING INTERFACE UNIT TO MAIN


FABRIC

(H)

A2SU :- (SN+) AALTUPE 2 SWITCHINGUNIT

1) PERFORM MINIPACKET SWITCHING OF AAL2 CPS


2) COLLECT AAL2 LAYER STATICS
(I)

TBU :- (2) TIMING & BUFFERING UNIT

1) RESPONSIBLE FOR THE NETWORK ELEMENT SYNCHRONIZATION


2) OPERATES IN PLESIOCHRONOUS MODE, IF ALL SYNCHRONISATION ARE LOST
(J)

NEMU :- NETWOK ELEMENT MANAGEMENT UNIT


1) LOCAL USER INTERFACE
2) PROVIDE INTERFACE TO HIGHER LEVEL CONTROL

(K) OMS :- (SN+) OPERATION & MAINTANCE SERVER


1) GRAPHICAL INTERFACE
2) NMS INTERFACE
INTERFACE USE IN RNC
1) PHYSICAL INTERFACE :-

NPS1 OPTICAL INTERFACE & NPGE ETHERNET INTERFACE

2) TIMING& SYNCHRONISATION INTERFACE


3)LAN/ ETHERNET INTERFACE
UTRAN
NETWORK(CN)
NODEB+ RNC
GMSC+EIR+HLR/AC
INTERFACE BETWEEN SGSN & GGSN------ Gn

CORE
SGSN+GGSN & MSC/VLR+

INTERFACE BETWEEN GGSN & PDN-------- Gi


INTERFACE BETWEEN SGSN & MSC/VLR---- Gs
INTERFACE BETWEEN SGSN & EIR, HLR, SCP------ Gf
INTERFACE BETWEEN GGSN & HLR/AC-------INTERFACE BETWEEN MSC & RNC--------- IUCS
INTERFACE BETWEEN SGSN & RNC---------- IUPS
INTERFACE BETWEEN RNC & CELL OROADCAST CENTRE(CBC)---IU-BC
The RNC2600 can be equipped for three different hardware configuration steps
1) RNC2600/1540 (Step 1) :- consists of 1 cabinet with all the sub racks fully equipped

2) RNC2600/2520 (Step 2):-consists of 2 cabinets - cabinet 1 with all sub racks fully
equipped and cabinet 2 with
the first two sub racks fully equipped

3) RNC2600/3500 (Step 3):-consists of 2 cabinets - cabinet 1 with all sub racks fully
equipped and cabinet 2 with
all the sub racks fully equipped
STEPS
DMCU

STM-1
MXU

GE ETHERNET

1
18

48 OR 24+24
8

16 OR 8+8

2
28

80 OR 40+40
12

24 OR 12+24

3
38

112 OR 56+56
16

32 OR 16+16

Functional Unit
DMCU
for one active unit

NPS1/P
6
10
14

NPGE/P

ICSU

14

12

26

16

38

Redundancy Principle
SN+

EHU

NONE

ICSU

N+1

Duplication (2N):-

one spare unit designated

MXU

2N

OMS
NONE
Replacement (N+1) :- one or more units
designated to be spare units for a group
OMU

2N

RSMU

2N

SFU
2N
group acts as a resource pool
TBU

2N

WDU

2N

OMS HDD

Load sharing (SN+):-

2N

NPS1
NONE
requirements for reliability

NONE :-

NPGE

NONE

NPS1P

2N (MSP 1+1/APS1+1)

NPGEP

2N (MSP 1+1/APS1+1)

Unit type

Plug in Unit type

SFU

SF20H

MXU

MX1G6-A

OMU

CCP18-A

OMS
MCP18-B
SWU

ESA24

ICSU

CCP18-C

RSMU

CCP18-C

DMCU
WDU (OMU)

no spare units,

CDSP-DH
WDW73

No redundancy no special

HDD (OMS)
NPGEP/NPGE 0

WDW73
NP2GE-B

NPS1P/NPS1 0

NPS1P/NPS1 0

TBU/TBUF

TSS3
PD30

SUBRACK PWR

You might also like