You are on page 1of 3

CARLOS,NOSCAL,ULANDAY,VENUS

GROUP 2
ELECTRONICS_5
OCTOBER 6, 2015
1.

The op-amp integrator uses


B. A positive reference voltage

A. Inductors
C. The dc supply voltage
B. The Miller effect
D. A negative reference voltage
C. Sinusoidal inputs
D. Hysteresis

6. In an ac amplifier using an op amp with


coupling and

2.

bypass capacitors, the output offset voltage is

A thermistor converts

A. Light to resistance

A. Zero

B. Temperature to resistance

B. Minimum

C. Voltage to sound

C. Maximum

D. Current to voltage

D. Unchanged

3.

7.

A D/A converter is an application of the

To use an op amp, you need at least

A. Adjustable bandwidth circuit

A. One supply voltage

B. Noninverting amplifier

B. Two supply voltages

C. Voltage-to-current converter

C. One coupling capacitor

D. Summing amplifier

D. One bypass capacitor

4. In an op-amp integrator, the current


through the input

8. With zero volts on both inputs, an op-amp


ideally should

resistor flows into the


have an output equal to
A. Inverting input
A. the positive supply voltage
B. Noninverting input
B. the negative supply voltage
C. Bypass capacitor
C. zero
D. Feedback capacitor
D. the CMRR
5. To use a comparator for zero-level
detection, the inverting input is connected to

9.

A. Ground

A. resistor

In an integrator, the feedback element is a

CARLOS,NOSCAL,ULANDAY,VENUS
GROUP 2
ELECTRONICS_5
OCTOBER 6, 2015
B. capacitor

B. DMM

C. zener diode

C. Oscilloscope

D. voltage divider

D. Telescope

10. For a step input, the output of an integrator


is
A. a pulse

14. What piece of equipment in an


oscilloscope is used to indicate pulse condition
in a

B. a triangular waveform
digital logic circuit?
C. a spike
A. Probe
D. a ramp
B. Test prods
11. What refers to the application of electronic
theory, technology, instrumentation, and
computing system to biological research and
medical problems?
A. Medical electronics

C. Connector
D. Logic probe
15. What instrument is used to measure the
amount of active ingredients in the electrolyte
of

B. Genetics electronics
a battery?
C. Biomedical engineering
A. Hygrometer
D. Biomedical electronics
B. Voltmeter
12. What instrument is used for measuring the
amount of current flowing in a circuit?

C. Electrometer

A. Voltmeter

D. Hydrometer

B. Ammeter

16. What is concerned with the measurement


of electric signals on the scalp with arise from

C. Oscilloscope
D. Meter amperage
13. What instrument is used for observing
voltage and current waveforms?

the underlying neural activity in the brain


(including synaptic sources)?
A. ECG
B. EEG

A. Multimeter

CARLOS,NOSCAL,ULANDAY,VENUS
GROUP 2
ELECTRONICS_5
OCTOBER 6, 2015
C. Ultrasound
D. Hydraulic
D. EKG
17. What ammeter is used to measure highfrequency currents?
A. Hot-wire
B. Moving-iron
C. Dynamometer
D. Thermocouple
18. A user-program that has the ability to move
a robot axis to any position within its range
A. Point-to-point
B. Continuous path
C. Positive stop
D. Pick-and-place
19. _________ includes two of the actuator
type used in industrial robots
A. Pneumatic and jointed arm
B. Hydraulic and pneumatic
C. Electric and spherical
D. Hydraulic and cylindrical
20. What type of actuator of industrial robots
has a great force capability and great holding
strength when stopped?
A. Pneumatic
B. Steam
C. Electric

You might also like