You are on page 1of 4

Example: Design of a cold-formed steel lipped channel wall stud in compression

Discuss me ...

CALCULATION SHEET

Document Ref:

SX024a-EN-EU

Title

Example: Design of a cold-formed steel lipped channel wall


stud in compression

Eurocode Ref

EN 1993-1-3

Made by

V. Ungureanu, A. Ruff

Date

Jan 2006

Checked by

D. Dubina

Date

Jan 2006

Sheet

of

Example: Design of a cold-formed steel lipped


channel wall stud in compression
This example deals with the design of a pinned wall stud subjected to
compression. The stud is composed of a cold-formed lipped channel section
where boards are attached to both flanges and they prevent buckling in the
weak direction and torsional buckling.
For practical design of light gauge sections to EN1993, designers will normally use software
or refer to manufacturers data. This example is presented for illustrative purposes

Created on 23 May 2013


This material is copyright - all rights reserved. Use of this document is subject to the terms and conditions of the Steelbiz Licence Agreement

Basic Data
Height of stud

H = 2,75 m

Spacing between studs

S = 0,6 m

Span of floor

L=5m

Spacing between floor joists

S = 0,6 m

Distributed loads applied to the floor:


dead load lightweight slab

1,00 kN m 2
qG = 1,00 0,6 = 0,60 kN m

imposed load

2,50 kN m 2
qQ = 2,50 0,6 = 1,50 kN m

ULS Limit State concentrated load from upper level and roof: Q = 10,0 kN
The dimensions of one cross-section and the material properties are:
Total height

h = 100 mm

Total width of flange

b = 40 mm

Total width of edge fold

c = 15 mm

Internal radius

r = 3 mm

Nominal thickness

t nom = 1 mm

Steel core thickness

t = 0,96 mm

Basic yield strength

f yb = 350 N mm 2

Modulus of elasticity

E = 210000 N mm 2

Poissons ratio

= 0,3

Shear modulus

G=

E
= 81000 N mm 2
2(1 + )

Example: Design of a cold-formed steel lipped channel wall stud in compression


Discuss me ...

CALCULATION SHEET

Document Ref:

SX024a-EN-EU

Title

Example: Design of a cold-formed steel lipped channel wall


stud in compression

Eurocode Ref

EN 1993-1-3

Made by

V. Ungureanu, A. Ruff

Date

Jan 2006

Checked by

D. Dubina

Date

Jan 2006

Partial factors

Sheet

of

EN1993-1-3
2(3)

M0 = 1,0

M1 = 1,0
G = 1,35

permanent loads

Q = 1,50

variable loads

EN1990

Derived data (section properties and action effects)


Properties of the gross cross-section
Gross cross-section area:

A = 198 mm 2

Position of z-z axis of the gross cross section with respect to the web:

yc = 12,88 mm

Created on 23 May 2013


This material is copyright - all rights reserved. Use of this document is subject to the terms and conditions of the Steelbiz Licence Agreement

Properties of the effective cross-section


Effective area of the cross-section in compression:

Aeff = 118 mm 2

Position of z-z axis of the effective cross-section with respect to the web:
y c,eff = 15,92 mm

Effective section modulus for bending about weak axis:


Weff, z, com = 1274 mm 3

EN1993-1-3
5.5.3.1
5.5.3.2
EN1993-1-5
4.4, and
SX022,
SX023

Weff, z, ten = 2585 mm 3

The applied concentrated load on the stud (only compression)

N Ed = ( G qG + Q qQ )L + Q = (1,35 0,6 + 1,50 1,50 ) 5 + 10 = 25,3 kN

EN1990

Resistance check of the cross-section


The following condition should be satisfied:
M
+ M z,Ed
N Ed
+ z,Ed
1
N c,Rd
M cz,Rd,com

EN1993-1-3
6.1.9(1)

Example: Design of a cold-formed steel lipped channel wall stud in compression


Discuss me ...

CALCULATION SHEET

Document Ref:

SX024a-EN-EU

Title

Example: Design of a cold-formed steel lipped channel wall


stud in compression

Eurocode Ref

EN 1993-1-3

Made by

V. Ungureanu, A. Ruff

Date

Jan 2006

Checked by

D. Dubina

Date

Jan 2006

Sheet

where:

6.1.4

M cz, Rd, com = Weff, com f yb / M0


M z,Ed = N Ed eNz

EN1993-1-3
6.1.9 (2)

eNz is the shift of centroidal z-z axis


M z,Ed = 0
eNz = yc,eff yc = 15,92 15,5 = 3,04 mm

The resistance check is:

Created on 23 May 2013


This material is copyright - all rights reserved. Use of this document is subject to the terms and conditions of the Steelbiz Licence Agreement

of

EN1993-1-3
6.1.3

N c, Rd = Aeff f yb M0

25300
0 + 25300 3,04
+
= 0,785 < 1
118 350 1,0 1274 350 1,0

OK

Example: Design of a cold-formed steel lipped channel wall stud in compression


Discuss me ...

Example: Design of a cold-formed steel lipped channel wall stud in compression


SX024a-EN-EU

Quality Record
RESOURCE TITLE

Example: Design of a cold-formed steel lipped channel wall stud in


compression

Reference(s)
ORIGINAL DOCUMENT
Name

Company

Date

Created by

V. Ungureanu, A. Ruff

BRITT Ltd. Timisoara,


Romania

Technical content checked by

D. Dubina

BRITT Ltd. Timisoara,


Romania

1. UK

G W Owens

SCI

12/4/06

2. France

A Bureau

CTICM

12/4/06

3. Sweden

B Uppfeldt

SBI

11/4/06

4. Germany

C Mller

RWTH

11/4/06

5. Spain

J Chica

Labein

12/4/06

G W Owens

SCI

19/7/06

Editorial content checked by

Created on 23 May 2013


This material is copyright - all rights reserved. Use of this document is subject to the terms and conditions of the Steelbiz Licence Agreement

Technical content endorsed by the


following STEEL Partners:

Resource approved by Technical


Coordinator
TRANSLATED DOCUMENT
This Translation made and checked by:
Translated resource approved by:

You might also like