You are on page 1of 20

BTS3900 Series BTS Monitoring Cable Installation Guide for Telenor SBR V1.

BTS3900 Series BTS Monitoring Cable


Installation Guide for Telenor SBR
Version 1.1

Date

Revision

Description

Author

2010-1014

V1.0

Completed the initial draft.

Zhang Youfang

2009-1020

V1.1

Added the configuration contents.

Zhang Youfang

-1-

BTS3900 Series BTS Monitoring Cable Installation Guide for Telenor SBR V1.1

1 Summary
1. There is only one monitoring cable between the 2 cabinet. Refer to the Chapter 4.
2. ONLY straight through cable can be used.
3. We configure the 3G BTS type the same as the 2G.

2 Overview of BTS3900A Cabinet


2.1 Exterior and configurations of the APM30H

No.

Module
1 Fan box

Description
The fan box is configured with the fan, the Hert Power Monitoring
Interface unit (HPMI), and the Central Monitoring Unit type A
(CMUA), dissipating the heat in the cabinet.

2 SLPU

The Signal Lightning Protection Unit (SLPU) is a mandatory


component installed in the top 1 U space of the cabinet, providing
protection for trunk signals.

3 EPS subrack

The EPS subrack provides functions of AC power distribution and


DC power distribution for the cabinet.
The BBU3900 processes the baseband signals and enables
interaction between the base station and the BSC or RNC.
The Power Supply Unit (PSU) converts 110 V AC or 220 V AC
power into -48 V DC power.
The Power Monitoring Unit (PMU) provides the functions of power
system and battery management, power monitoring, and alarm
reporting

4 BBU3900
5 PSU
(AC/DC)
6 PMU

-2-

BTS3900 Series BTS Monitoring Cable Installation Guide for Telenor SBR V1.1

2.2 Exterior and configurations of the RFC

No.

Module
1 DCDU-01
2 Fan box

3 RFU

Description
The Direct Current Distribution Unit-01 (DCDU-01) supplies power
to each component in the cabinet.
The fan box is configured with the fan and CMUA. The fan
dissipates the heat in the cabinet, and the CMUA provides the
functions of the temperature control, Boolean alarm detection, and
ELU identification of the cabinet.
The Radio Frequency Unit (RFU) performs modulation and
demodulation between baseband signals and RF signals,
processes data, and combines and divides signals.

2.3 Exterior and configurations of the TMC11H

No.

Module
1 Fan box
3 DCDU-03

Description
The fan box is configured with the fan, HPMI, and CMUA,
dissipating the heat in the cabinet.
The Direct Current Distribution Unit-03 (DCDU-03) supplies power
to each component in the TMC11H.

2.4 Exterior and configurations of the IBBS200D

-3-

BTS3900 Series BTS Monitoring Cable Installation Guide for Telenor SBR V1.1

No.

Module
1 Fan

3 Power
distribution
box

Description
The fan is installed on the front door of the cabinet, dissipating the
heat in the cabinet.
The CMUA provides the functions of the temperature control,
Boolean alarm detection, and ELU identification of the cabinet.
The power distribution box is installed on the upper right of the
cabinet, transferring the distributing the power to the TEC cooler or
fan and to the batteries.

4 Battery

The battery provides long-duration backup power for a base station

2 CMUA

2.5 Exterior and configurations of the IBBS200T

No.

Module
1 TEC cooler

Description
The TEC cooler is installed in the protecting hood for the TEC
cooler on the front door of the cabinet. The TEC cooler consists of
the TEC, inner air circulation fan, outer air circulation fan, heatdissipation piece, and monitoring board

2 CMUA
3 Power
distribution
box

The CMUA provides the functions of the temperature control,


Boolean alarm detection, and ELU identification of the cabinet.
The power distribution box is installed on the upper right of the
cabinet, transferring the distributing the power to the TEC cooler or
fan and to the batteries.

4 Battery

The battery provides long-duration backup power for a base station

3 Monitoring Cable and Port Position


3.1 Monitoring cable
ONLY straight through cable can be used.
The monitoring signal cable connects two CMUAs.

-4-

BTS3900 Series BTS Monitoring Cable Installation Guide for Telenor SBR V1.1

(1) RJ-45 connector


Table 1 Pin assignment for the wires of the FE/GE cable
Pin on the RJ-45 Connector

Wire Color

X1.2

Orange

X1.1

White and orange

X1.6

Green

X1.3

White and green

X1.4

Blue

X1.5

White and blue

X1.8

Brown

X1.7

White and brown

Wire Type

Pin on the RJ-45 Connector

Twisted pair X2.2


X2.1
Twisted pair X2.6
X2.3
Twisted pair X2.4
X2.5
Twisted pair X2.8
X2.7

3.2 APM30H
COM_IN: RS485 signal port connected to the BBU or upper-level CMUA and used to report
monitoring information
COM_485: RS485 signal port communicating with the battery cabinet
MON0: No.0 RS485 signal input port

-5-

BTS3900 Series BTS Monitoring Cable Installation Guide for Telenor SBR V1.1

3.3 RFC
COM_IN: RS485 signal port connected to the BBU or upper-level CMUA and used to report
monitoring information
COM_OUT: RS485 signal port connected to the PMU or lower-level CMUA and used to receive
monitoring information

3.4 TMC11H
COM_IN: RS485 signal port connected to the BBU or upper-level CMUA and used to report
monitoring information

3.5 IBBS200D/IBBS200T
COM_IN: RS485 signal port connected to the BBU or upper-level CMUA and used to report
monitoring information

-6-

BTS3900 Series BTS Monitoring Cable Installation Guide for Telenor SBR V1.1
COM_OUT: RS485 signal port connected to the PMU or lower-level CMUA and used to receive
monitoring information

4 Monitoring cable Installation


All the monitoring cables which are mentioned in this chapter need to be connected on site.

4.1 BTS3900A DC 1*TMC11H+1*RFC


Connection:
None monitoring cable need to be connected.

Date configuration:

-7-

BTS3900 Series BTS Monitoring Cable Installation Guide for Telenor SBR V1.1
No.0 TMC11H (0)

(1; 7)

(0; 22)
RFC0 (1)

(0; 14)

BTS Type:
2G: BTS3900A (DC)
3G: BTS3900A (DC) + RRU
Cabinet ID (Cabinet
Name)

Part ID (Part
Name)

No.0 TMC11H

Cabinet ID

Subrack ID

Slot ID

Connected Serial No.

Communication Address

TCU0

RFC0

FMU0

11

14

No.0 TMC11H

GATM0

50

22

4.2 BTS3900A DC 1*TMC11H+2*RFC


Connection:
1. COM_OUT(RFC) to COM_IN(Extension RFC)

-8-

BTS3900 Series BTS Monitoring Cable Installation Guide for Telenor SBR V1.1

Date configuration:
No.0 TMC11H (0)

(1; 7)

(0; 22)
RFC0 (1)

(0; 15)

(0; 14)

RFC1 (2)

BTS Type:
2G: BTS3900A (DC)
3G: BTS3900A (DC) + RRU
Cabinet ID (Cabinet
Name)

Part ID (Part
Name)

No.0 TMC11H
RFC0

Cabinet ID

Subrack ID

Slot ID

Connected Serial No.

Communication Address

TCU0

FMU0

11

14

-9-

BTS3900 Series BTS Monitoring Cable Installation Guide for Telenor SBR V1.1
RFC1

FMU1

11

15

No.0 TMC11H

GATM0

50

22

4.3 BTS3900A AC 1*APM30H+1*RFC+1*IBBS200


Connection:
1. COM_485(APM30H) -- COM_IN(IBBS)

Date configuration:
IBBS0 (9)

(1; 3)

No.0 APM30 (0)

(1; 23)

(0; 22)
RFC0 (1)

(0; 14)

BTS Type:

- 10 -

(1; 7)

BTS3900 Series BTS Monitoring Cable Installation Guide for Telenor SBR V1.1
2G: BTS3900A (AC)
3G: BTS3900A (AC)
Cabinet ID (Cabinet
Name)

Part ID (Part
Name)

referenced Cabinet ID
(BSC6900)

Subrack
ID

Slot
ID

Connected Serial
Port ID

Communication
Address

No.0 APM30

PMU0

No.0 APM30

TCU0

RFC0

FMU0

11

14

No.0 APM30 BBC0

BBC TCU0

23

No.0 APM30

GATM0

50

22

4.4 BTS3900A+DBS3900 AC 2*APM30H+1*RFC+2*IBBS200


Connection:
1. MON0(APM30H UEIU) -- COM_IN(Extension APM30H );
2. COM_485(APM30H) -- COM_IN(IBBS200);
3. COM_485(Extension APM30H) -- COM_IN(Extension IBBS200);

Date configuration:
IBBS0 (9)

(1; 3)

No.0 APM30 (0)

(1; 7)

No.1 APM30 (5)


(0; 7)

(1; 23)

IBBS1 (11)
(0; 3)
(0; 23)

(0; 22)
RFC0 (1)

(0; 14)

BTS Type:
2G: BTS3900A (AC)
3G: BTS3900A (AC) +RRU

- 11 -

BTS3900 Series BTS Monitoring Cable Installation Guide for Telenor SBR V1.1

Cabinet ID (Cabinet
Name)

Part ID (Part
Name)

referenced Cabinet ID
(BSC6900)

Subrack
ID

Slot
ID

Connected Serial
Port ID

No.0 APM30

PMU0

No.1 APM30

PMU1

No.0 APM30

TCU0

No.1 APM30

TCU1

RFC0

FMU0

11

14

No.0 APM30 BBC0

BBC TCU0

23

No.1 APM30 BBC0

BBC TCU0

11

23

No.0 APM30

GATM0

50

22

4.5 BTS3900A AC 2*APM30H+2*RFC+2*IBBS200


Connection:
1. MON0(APM30H UEIU) -- COM_IN(Extension APM30H );
2. COM_OUT(RFC) -- COM_IN(Extension RFC);
3. COM_485(APM30H) -- COM_IN(IBBS200);
4. COM_485(Extension APM30H) -- COM_IN(Extension IBBS200);

Date configuration:

- 12 -

Communication
Address

BTS3900 Series BTS Monitoring Cable Installation Guide for Telenor SBR V1.1

IBBS0 (9)

(1; 3)

No.0 APM30 (0)

(1; 7)

No.1 APM30 (5)


(0; 7)

IBBS1 (11)
(0; 3)

(1; 23)

(0; 23)

(0; 22)
RFC0 (1)

(0; 15)

(0; 14)

RFC1 (2)

BTS Type:
2G: BTS3900A (AC)
3G: BTS3900A (AC) +RRU
Cabinet ID (Cabinet
Name)

Part ID (Part
Name)

referenced Cabinet ID
(BSC6900)

Subrack
ID

No.0 APM30

PMU0

No.1 APM30

PMU1

No.0 APM30

TCU0

No.1 APM30

TCU1

RFC0

FMU0

11

14

RFC1

FMU1

11

15

No.0 APM30 BBC0

BBC TCU0

23

No.1 APM30 BBC0

BBC TCU0

11

23

No.0 APM30

GATM0

50

22

4.6 DBS3900 AC 1*APM30H+1*IBBS200


Connection:
1. COM_485(APM30H) -- COM_IN(IBBS200);

Date configuration:

- 13 -

Slot
ID

Connected Serial
Port ID

Communication
Address

BTS3900 Series BTS Monitoring Cable Installation Guide for Telenor SBR V1.1

IBBS0 (9)

(1; 3)

No.0 APM30 (0)

(1; 7)

(1; 23)

(0; 22)

BTS Type:
3G: DBS3900
Cabinet ID (Cabinet
Name)

Cabinet ID
(BSC6900)

referenced Cabinet ID
(BSC6900)

Subrack
ID

Slot
ID

Connected Serial
Port ID

No.0 APM30

PMU0

No.0 APM30

TCU0

No.0 APM30 BBC0

BBC TCU0

23

4.7 BTS3900A AC 1*APM30H+1*TMC11H+1*RFC+1*IBBS200


Connection:
1. COM_OUT(RFC) COM_IN(TMC11H)
2. COM_485(APM30H) -- COM_IN(IBBS)

Date configuration:

- 14 -

Communication
Address

BTS3900 Series BTS Monitoring Cable Installation Guide for Telenor SBR V1.1

IBBS0 (9)

(1; 3)

No.0 APM30 (0)

(1; 7)

TMC11H (8)
(0; 6)

(1; 23)

(0; 22)
RFC0 (1)

(0; 14)

BTS Type:
2G: BTS3900A (AC)
3G: BTS3900A (AC) +RRU
Cabinet ID (Cabinet
Name)

Part ID (Part
Name)

referenced Cabinet ID
(BSC6900)

Subrack
ID

Slot
ID

Connected Serial
Port ID

Communication
Address

No.0 APM30

PMU0

No.0 APM30

TCU0

TMC11H

TCU3

RFC0

FMU0

11

14

No.0 APM30 BBC0

BBC TCU0

23

No.0 APM30

GATM0

50

22

5 Default Internal monitoring Cable


All the monitoring cables which are mentioned in this chapter have been connected in the factory. We
dont need to connect these cable on site.
If any module in the APM30H has been reallocated, these monitoring cables must be checked.

5.1.1 BTS3900A DC
1. MON1 (TMC11H UPEU) -- COM_IN(TMC11H)
2. MON0 (TMC11H UPEU) -- COM_IN(RFC)

- 15 -

BTS3900 Series BTS Monitoring Cable Installation Guide for Telenor SBR V1.1

5.1.2 BTS3900A AC
1. MON1 (APM30H UPEU) -- COM_IN(APM30H)
2. MON0 (APM30H UPEU) -- COM_IN(RFC)
3. COM_OUT(APM30H) COM_IN(PMU)

5.1.3 DBS3900
1. MON1 (APM30H UPEU) -- COM_IN(APM30H)
2. COM_OUT(APM30H) COM_IN(PMU)

- 16 -

BTS3900 Series BTS Monitoring Cable Installation Guide for Telenor SBR V1.1

5.1.4 BTS3900L
1. S1: MON0 (BBU UPEU) -- COM_IN(Lower FMU)
2. S3: COM_OUT(Lower FMU) COM_IN(Upper FMU)

- 17 -

BTS3900 Series BTS Monitoring Cable Installation Guide for Telenor SBR V1.1

5.1.5 GATM
The GATM panel is as below:

Port ID
ANT0 to
ANT5
COM1
COM2
-48 V

Connector
SMA female
connector
RJ-45
connector
RJ-45
connector
3V3 power
connector

Function
Providing power and transmitting control signals for the RET
antenna
Connecting to the BBU
Serving as an extended RS485 port for connecting to other devices
Feeding -48 V DC power

The GATM monitoring cable is connected in the factory.


Outdoor BTS3900A
1. MON0 (APM30H UPEU) -- COM1(GATM)
2. COM2(GATM) -- COM_IN(RFC)

Indoor BTS3900L
1. MON0 (APM30H UPEU) -- COM1(GATM)
2. COM2(GATM) -- COM_IN(FMU0)
3. COM_OUT(FMU0) COM_IN(FMU1)

- 18 -

BTS3900 Series BTS Monitoring Cable Installation Guide for Telenor SBR V1.1

6 Cabinet Configuration
BTS3900A AC
BTS3900A Actual Physical Configuration

Parameters to Be Configured During Site Construction

Cabinet ID (Cabinet
Name)

Part ID (Part
Name)

referenced Cabinet ID
(BSC6900)

No.0 APM30

PMU0

No.1 APM30

PMU1

No.2 APM30

PMU2

No.0 APM30

TCU0

No.1 APM30

TCU1

No.2 APM30

TCU2

TMC11H

TCU3

RFC0

FMU0

11

14

RFC1

FMU1

11

15

RFC2

FMU2

11

14

RFC3

FMU3

11

15

No.0 APM30 BBC0

BBC TCU0

23

No.0 APM30 BBC1

BBC TCU1

10

24

No.1 APM30 BBC0

BBC TCU0

11

23

No.1 APM30 BBC1

BBC TCU1

12

24

No.2 APM30 BBC0

BBC TCU0

13

25

No.2 APM30 BBC1

BBC TCU1

14

26

No.0 APM30

GATM0

50

22

No.0 APM30

GATM1

51

22

Subrack
ID

Slot
ID

Connected Serial
Port ID

Communication
Address

BTS3900A DC
BTS3900A DC Actual Physical
Configuration
Cabinet ID (Cabinet
Part ID (Part
Name)
Name)

Parameters to Be Configured During Site Construction


referenced Cabinet ID
(BSC6900)

Subrack
ID

Slot
ID

Connected Serial
Port ID

Communication
Address

No.0 TMC11H

TCU0

RFC0

FMU0

11

14

RFC1

FMU1

11

15

No.0 TMC11H

GATM0

50

22

No.0 TMC11H

GATM1

51

22

DBS3900
DBS3900 Actual Physical Configuration

Parameters to Be Configured During Site Construction

Cabinet ID (Cabinet
Name)

Cabinet ID
(BSC6900)

referenced Cabinet ID
(BSC6900)

No.0 APM30

PMU0

No.1 APM30

PMU1

No.0 APM30

TCU0

No.1 APM30

TCU1

- 19 -

Subrack
ID

Slot
ID

Connected Serial
Port ID

Communication
Address

BTS3900 Series BTS Monitoring Cable Installation Guide for Telenor SBR V1.1
TMC11H

TCU2

No.0 APM30 BBC0


No.0 APM30 BBC1

BBC TCU0

23

BBC TCU1

10

24

No.1 APM30 BBC0

BBC TCU0

11

23

No.1 APM30 BBC1

BBC TCU1

12

24

BTS3900L
BTS3900L Actual Physical Configuration

Parameters to Be Configured During Site Construction

Cabinet ID (Cabinet Name)

Part ID (Part Name)

Cabinet ID

Subrack ID

Slot ID

Connected Serial No.

No.0 BTS3900L

FMU0

11

14

No.0 BTS3900L

FMU1

12

15

No.0 BTS3900L

GATM0

50

22

No.0 BTS3900L

GATM1

51

22

- 20 -