RS485 is the only differential interface allowing for robust data


transmission over miles -- long distances at reasonably high data rates of
up to 100kbps. Preferably bus nodes are connected by daisy-chain, or a
single cable run that connects one node to the next. Because each node
receives its power supply from a different point in the electrical installation, ground potential
differences (GPDs) between bus nodes are common.
Figure 1

What is low-side current sensing?


3 comments
A quick reminder, low-side current-sensing is where the
sense element, or shunt resistor, is placed in series with the
load between the load and ground
Intrinsic op amp noise in a nut shell
For those wanting a quick and simple method to minimize
noise, this article is for you.
Common-mode voltage for industrial transceivers
1 Comment
Most differential field bus technologies, like CAN and RS485,
specify a parameter called common-mode voltage. Commonmode voltage refers to the range of bus input voltages, with
respect to the transceivers ground, within which the
transceiver maintains consistent input receiver thresholds.
SIGNAL CHAIN BASICS (Part 104): Understanding noise in
ADCs
1 Comment
As a data converter supplier, we are sometimes asked, which
is our lowest noise analog-to-digital converter (ADC)?

RS485 bus with ground potential differences between bus nodes

These GPDs increase the common-mode voltage on the bus and can cause data errors or
device damage, if not properly dealt with. RS485-compliant transceivers tolerate GPDs of up to
7V. Higher GPDs however require special transceivers with a higher input voltage range, or
galvanically isolated transceivers.
Some engineers use ground wires between bus nodes in order to tie the transceiver grounds
to a defined voltage potential. This method can have dangerous outcomes as it shortens
multiple ground potential differences together causing prohibitively large ground currents that
literally burn ground wires.

SIGNAL CHAIN BASICS (Part 103): Integer Boundary Spurs


The phase-locked loop (PLL) in Figure 1 works by starting
with a stable input frequency (fOSC). It is divided down by R to
get the phase detector frequency (fPD), then multiplied by N to
get the voltage-controller oscillator (VCO) frequency (fVCO).
Finally, it is divided down by D to get the output frequency
(fOUT). The output divider, D, is typically an integer, but it is
possible for the N divider to be fractional. Devices can exist
with multipliers on the input path, effectively making R
fractional.
MORE FROM SIGNAL CHAIN BASICS

On the basis of a single point-to-point interface, this article shows that differential transceivers
are designed to operate without ground wires.
The differential driver has a H-bridge output stage that drives current from terminal A to
terminal B and vice versa, depending on the logic states at data input, D (Figure 2).
Figure 2

SPONSORED CONTENT
100 data converter technical resources at your
fingertips
TIs new Data Converter Learning Center
organizes more than 100 technical articles, blog posts
and videos by topics, such as precision, high-speed,
input signal conditioning, data input/output, power
management and more.
converted by W eb2PDFConvert.com

Sponsored By Texas Instruments

flash poll
This will be a problem by 2020 since
projected STEM-related job growth
increases will be 62% for Biomedical
Engineers, 36% Medical Scientists, 32%
for System Software Developers, 22% for
Computer Systems Analysts, and 16% in
Mathematics. How can we get young
potential people interested?
More Government STEM funding in preschool
through 12th grade
Increasing public and youth engagement in STEM
programs by government and industry
H-bridge output stage

Improve STEM experiences for undergrads

Because the line voltages, VA and VB, switch between two positive potentials, the driver can be
modeled as a signal source with a common-mode output offset, VOS, and a superimposed
differential voltage of VOD/2 (Figure 3).

Increase interest and awareness in STEM groups


now underrepresented in STEM fields
Design graduate education towards a stronger
STEM workforce

Figure 3

More industry involvement in STEM


Submit
All polls

Driver model and line voltages

The differential receivers input stage consists of a resistor network that attenuates large input
signals and biases the comparator inputs with respect to receiver ground (Figure 4). By
referencing the inputs to receiver ground, the receiver can build the voltage difference
between VA and VB without a ground connection between driver and receiver ground.
Figure 4

educational resources
1.4GHz Low Jitter PLL with Clock Distribution Solves
Difficult Clocking Problems
Best Practical Jitter Tolerance Testing with MP1800A
TI Vision SDK, Optimized Vision Libraries for ADAS
Systems
Challenges in Temperature Sensor Measurement Solved
by Precision Temperature-to-Bits Converter
New Linear Regulators Solve Old Problems
Dynamic power path management in battery chargers: a
highly integrated implementation
uModule Buck-Boost Regulators Offer a Simple Solution for
Wide Input/Output Voltage Range Applications
Differential receiver input stage

Voltage divider action between the input resistors (Rin) and the bias resistors (Rb) attenuates
the input signal (common-mode and differential voltage components likewise) by a factor of
ten. This prevents the comparator inputs from saturation (Figure 5).

RF/IF Amplifiers with OIP3 of 47dBm/50dBm at 240MHz


Ease Implementation, Guarantee Performance
CHALLENGES IN THE INTERNET OF THINGS (IOT)
Top 5 Challenges for RF Products

Figure 5

Improving Emulation Throughput for Multi-Project SoC


Designs
converted by W eb2PDFConvert.com

EDN Must Reads: Power Integration


An Improved and Simplified Interface Protocol for DDR
Memory
Bi-Directional Supercap Charger Integrates Backup &
Balancing
Automotive Designs Demand Low EMI Synchronous Buck
Converters
42V Quad Monolithic Synchronous Step-Down Regulator
with 30A Quiescent Current
Best Practices for Low Power RTL Design
Enhancing Automotive Electronics Reliability Checking
Design, Test & Repair Methodology for FinFET-Based
Memories
Selecting Current Sensors and Transformers: Choosing
the right current sensor does not need to be guesswork
Design Considerations for High-Speed RS-485 Data Links
Top 5 Challenges for Testing Todays Consumer
Electronics
Methods to Fine-Tune Power Consumption of PCIe devices
Addressing the need for ultra-small Ambient Light Sensors
in wearable products
Resistor network attenuates differential and common-mode signals

Device to Device Communication in LTE

Voltage divider action between the bias resistors biases the comparator inputs with VCC/2
potential, thus enabling the receiver to work from a single-supply voltage.

follow Planet Analog on Twitter


Page 1 / 2 Next >

Planet Analog @PlanetAnalog


7h
Function Generator Circuit Concepts,
Part 1: First-Generation Function
Generators (FGs) ubm.io/1SEkPei

Email This Print Comment

comments

NEWEST FIRST | OLDEST FIRST | THREADED VIEW


PAGE 1 / 2 > >>

TKUG
12/11/2013 10:57:19 AM
User Rank TEACHER

Login
Re: XFMR coupled manchester data over 485
actually I use Manchester coding for getting hihg data rates across long
cable runs. typically the higher cable capacitance cause increased
loading and ISI (inter-symbol interference) can close eyes quickly. Using 100% 0%
a clock and XOR-ing it with data gives you manchester encoded data. on
the receive side you either need to use a clock recovery circuit (typically
with 6 to 8 times higher frequency) for decoding, or you simply use a
second differential link for getting the clock to the receiver.

With a small RS422 IC, such as a dual driver and dual receiver IC, one
can accomplish this task quite easily. On the receiver side you simply
use another XOR to decode the encoded data with the received clock to
get to the original data. - Thomas

Planet Analog @PlanetAnalog 5 Nov


What is low-side current sensing?
ubm.io/1PqHlYh

Guido Burger @guido_burger 4 Nov


Planet Analog - Divya Thukkaram BNO055: A Sensor for the Makers
Community
planetanalog.com/author.asp?doc
via @PlanetAnalog
Retweeted by Thomas Block
Expand

Reply Post Message Messages List Start a Board


Re: XFMR coupled manchester data over 485
@William, thanks for the comment about the Alternate Mark Inversion
line coding. BR, Victor
Victor Lorenzo
12/10/2013 1:52:03 AM
User Rank BLOGGER

Login

Guido Burger @guido_burger 4 Nov


Planet Analog - Divya Thukkaram -

like us on facebook
50% 50%

Reply Post Message Messages List Start a Board

Planet Analog
3,801 likes

BillWM
12/9/2013 5:35:46 PM
User Rank BLOGGER

Re: XFMR coupled manchester data over 485


There are other line codings, as well as drive types -- T1/E1 uses
Alternate Mark Inversion to drive the transformer for example rather than
Manchester (tri-level signal) done with 485 this is either 1, Z, or 0 for
drive with 1, and 0 representing a Logic High and Z representing logic 0

Login
50% 50%

Reply Post Message Messages List Start a Board

Victor Lorenzo
12/9/2013 4:26:24 PM
User Rank BLOGGER

Re: XFMR coupled manchester data over 485


@Thomas, thanks for pointing us to the SN65HVD82 datasheet, as you
say, it contains usefull information about transients and their
suppression.

Like Page

Share

Be the first of your friends to like this


Login
50% 50%

Reply Post Message Messages List Start a Board

our partners

Login
Re: XFMR coupled manchester data over 485
1) sorry for my delayed response. I'm currently travelling through Asia. 2)
I do not have an application note for transformer isolation with
Manchester encoding. 3) transformer isolation is usually appllied on the 50% 50%
converted by W eb2PDFConvert.com

TKUG
12/9/2013 3:40:14 PM
User Rank TEACHER

bus side while isolation through opto-couplers is installed on the


control or logic side of the transceiver, i.e. between transceiver and
UART or MCU. Optos can be used at low data rates up to 100 kbps, as
they are dirt cheap (4 to 5 cents). At higher data rates, such as highspeed MODBUS or Profibus applications, RS-485 transceivers with
integrated digital (capacitive or magnetic) isolation are used.
Isolation prevents high common-mode voltages from corrupting your
data traffic, i.e. by preventing the flow of ground loop currents. Isolation
does NOT protect your bus node against fast transients from ESD or
EFT or Surge. TI has worked with Bourns on transient protection circuits
for RS-485 bus nodes. Please refer to the application section in the in
the SN65HVD82 data sheet on www.ti.com. I provide a lot of information
on the individual transient energies and their suppression. Figure 23 in
the data sheet has a detailed application circuit that should simplify your
protection design for an isolated bus node. Regards, Thomas
Reply Post Message Messages List Start a Board

Victor Lorenzo
12/9/2013 10:02:49 AM
User Rank BLOGGER

Re: XFMR coupled manchester data over 485


@William, Please, feel free to correct me if I'm wrong. At both ends of
the twisted pair we put termination resistors, and we tend to make both
wires of the twisted pair of almost the same length. In principle, the
voltage developed across both wires due to bias currents should be
almost identical but opposite in polarity.

Login
50% 50%

The wires resistance contributes to reducing the effective dynamic


range, but if you manage to use effectively isolated input/output stages
(floating, like in the LTC1535 isolated RS485 transceived, for citing one)
the effect of sending long strings of 0's or 1's should be minimum
provided that you're connecting directly to the bus. If isolation is
accomplished using transformers the DC ballance does show up as
the transformer blocks the DC level, in which case we need data
encodings like Manchester.
Have you used another encoding besides Manchester with isolation
transformers?
Reply Post Message Messages List Start a Board

BillWM
12/9/2013 7:45:55 AM
User Rank BLOGGER

Login
Re: XFMR coupled manchester data over 485
The real issue without the Manchester/Transformer arrangement is the
DC ballance issue where a long string on 1's or 0's causes a shift in the
voltage level on the reciever inputs when long wires with resistance are 50% 50%
used -- this can cause data to be interpreted as the wrong value or level
when no transformer / manchester code is used.

Reply Post Message Messages List Start a Board


Re: XFMR coupled manchester data over 485
@DaeJ, "Opto isolator (chip) has a limited voltage range, but cost is
inexpensive"
Victor Lorenzo
12/9/2013 7:40:23 AM
User Rank BLOGGER

Login
50% 50%

It all depends on many factors, there's a number of pulse transformers


with a fairly small footprint and relatively high bandwith (although this is
probably not the most appropiate term) available for less than 3$, and
'good' optocouplers with high isolation voltaje and rated at 5V/us or
more for industrial applications tend to be in the range from 2$ and up.
I think at the end its all up-to the application we're working on. The good
news here is we have plenty of options to chose from.
Reply Post Message Messages List Start a Board
Login

Re: XFMR coupled manchester data over 485


@William: "Do you know of any good app notes for XFMR coupled
manchester data over RS485"
Victor Lorenzo
12/9/2013 7:29:51 AM
User Rank BLOGGER

50% 50%

I'm just curious about that. Would you please comment a little bit about
it, specially about the need for the XFMR?
Reply Post Message Messages List Start a Board

Victor Lorenzo
12/9/2013 7:20:53 AM
User Rank BLOGGER

Good Post!
@Thomas, thanks for the post, it covers several key aspects about
RS485 and mentions several core concepts when interconnecting data
networks with this type of interface.

Login
50% 50%

The only part I miss here is the inputs protection, which is imperative to
be addressed by the designer.
Reply Post Message Messages List Start a Board
PAGE 1 / 2 > >>

converted by W eb2PDFConvert.com

PLANET ANALOG
ABOUT US CONTACT US HELP REGISTER TWITTER FACEBOOK RSS

Terms of Service | Privacy Statement | Copyright 2013 UBM Tech, All rights reserved

converted by W eb2PDFConvert.com

You might also like