You are on page 1of 3

DETAILED ANALYSIS

according to Eurocode 3 (EN 1993-1-5:2005)


for member no. 1 Bar_1

SECTION PARAMETERS: UB 356x171x45


ht=351 mm
bf=171 mm
tw=7 mm
tf=10 mm

Ay=3319 mm2
Iy=120700000 mm4
Wely=686966 mm3

Az=2460 mm2
Iz=8110000 mm4
Welz=94798 mm3

Ax=5730 mm2
Ix=158000 mm4

TRANSVERSE STIFFENERS
Stiffener positions: 2.92; 3.07
Translation: a = 0.00 m; b = 0.00 m
Stiffener 1
bilateral
ts = 7 mm
Stiffener 2
bilateral
ts = 7 mm

real coordinates
hs = 332 mm
hs = 332 mm

CONCENTRATED FORCES
Force positions: 0.00; 3.00; 6.00;
Force 1
F1 = 0.00 kN
Force 2
F2 = -25.00 kN
Force 3
F3 = 0.00 kN

real coordinates
ss1 = 125 mm
ss2 = 0 mm
ss3 = 125 mm

SHEAR BUCKLING RESISTANCE (EC3 art. 5)


Symbols:
Lam_w
kT
Xw
Xf
Xv
Mf,Rd
VEd

- relative web slenderness


- local buckling coefficient for shear
- Influence factor for shear resistance (web)
- Influence factor for shear resistance (flange)
- Instability factor for shear
- Design resistance of section flanges
- Maximum shear force in a panel

[5.2.(5)]
[A.3.(1)]
[5.3.(1)]
[5.4.(1)]
[5.2.(1)]
[5.4.(1)]
[5.2.(1)]

Vb,Rd

- Design shear buckling resistance

[5.2.(1)]

Panel coordinates A
x = (0.00 ; 0.49)
Panel A
Point x = 0.00 m
According to paragraph 5.1.(2), it is not necessary to check resistance to local shear buckling.
Panel coordinates B
x = (0.49 ; 0.51)
Panel B
Point x = 2.92 m
According to paragraph 5.1.(2), it is not necessary to check resistance to local shear buckling.
Panel coordinates C
x = (0.51 ; 1.00)
Panel C
Point x = 3.07 m
According to paragraph 5.1.(2), it is not necessary to check resistance to local shear buckling.

RESISTANCE OF WEBS TO TRANSVERSE FORCES (EC3 art.5.7)


Symbols:
ss
m1
m2
kF
Xf
Leff
FRd
Sigx.Ed
Sigz.Ed
Tau.Ed

- Length of stiff bearing


- Reduction factor Leff
- Reduction factor Leff
- Web buckling coefficient
- Reduction factor Leff
- Effective length of web
- Web resistance for local buckling
- Local stresses due to moment and axial force
- Local stresses due to transversal load
- Shear stress under a concentrated force

[Figure 6.2]
[6.5.(1)]
[6.5.(1)]
[Figure 6.1]
[6.4.(1)]
[6.2.(1)]
[6.2.(1)]
[EN 1993-1-1 &6.2.1.(5)]
[EN 1993-1-1 &6.2.1.(5)]
[EN 1993-1-1 &6.2.1.(5)]

Web stability under force FEd,1


Point x = 3.00 m
Governing load case: Manual Verification
Web resistance under a concentrated force (EC3 section 6.6.1)
ss = 0 mm
m1 = 24.44
m2 = 0.00
kF = 15.80
LamF = 0.25
Xf = 1.00
Leff = 115 mm
Frd = 189.69 kN
Check condition: (6.14)
FEd,1 = 25.00 kN < FRd = 189.69 kN
OK!
Interaction of transversal force, moment and axial force (EC3 section 7.2.(1))
Web in plane stress (EC3 art. 6.2.1.(5))
Sigx,Ed = 0.00 MPa
Sigx,Ed = 184.09 MPa Tau,Ed = 0.00 MPa
Check condition: (EN 1993-1-1 &6.2.1.(5))
(Sigx.Ed/(fy/g0))^2 + (Sigz.Ed/(fy/g0))^2 - (Sigx.Ed/(fy/g0))*(Sigz.Ed/(fy/g0)) + 3.0*(Tau,Ed/(fy/g0))^2 = 0.61 <
1.0 OK!

INTERACTION SHEAR/BENDING/AXIAL FORCE (EC3 art. 7.1)


Symbols:
My,Ed
Mz,Ed
NEd
VEd
Mf.Rd
My,pl.Rd
Vb.Rd
Panel A

- Design bending moment


- Design bending moment
- Design axial force
- Design shear force
- Design plastic moment resistance of a section consisting of flanges
[7.1.(1)]
- Design beam resistance at bending
[7.1.(1)]
- Design shear buckling resistance
[5.2.(1)]
Panel coordinates A

x = (0.00 ; 0.49)

Point x = 0.00 m
According to [7.1.(1)] checking of NTM interaction is not necessary (VEd/Vb,Rd < 0.5 );
Panel coordinates B
x = (0.49 ; 0.51)
Panel B
Point x = 2.92 m
According to [7.1.(1)] checking of NTM interaction is not necessary (VEd/Vb,Rd < 0.5 );
Panel coordinates C
x = (0.51 ; 1.00)
Panel C
Point x = 3.07 m
According to [7.1.(1)] checking of NTM interaction is not necessary (VEd/Vb,Rd < 0.5 );

TRANSVERSE STIFFENER RESISTANCE (EC3 art. 9)


Symbols:
bw
Ast
Ist
Sig,cr,c
Sig,cr,p
u
Sigm
Ist,min
Ip
It
Nst,Ed
Mst,Ed
Lam,st
Xst
Nst,b,Rd
eN
Mst,Rd

- Effective web width


[9.1.(2)]
- Stiffener area
[9.1.(2)]
- Moment of inertia of stiffener
[9.1.(2)]
- Critical Euler stress (column model)
[9.1.(5)]
- Critical Euler stress (plate model)
[9.1.(5)]
- Coefficient for calculations of Ist,min
[9.1.(5)]
- Stress due to lateral actions
[9.1.(5)]
- Minimum stiffness due to panel actions
[9.1.(5)]
- Polar moment of inertia of a stiffener
[9.1.(7)]
- Torsional moment of inertia of a stiffener
[9.1.(7)]
- Stiffener compressive force
[9.3.3.(3)]
- Additional moment due to lateral actions of panels
[9.1.(6)]
- Non-dimensional slenderness of stiffener due to buckling
[9.4.(2)]
- Stiffener buckling coefficient
[9.4.(2)]
- Stiffener buckling capacity
[9.1.(3)]
- Eccentricity of a compressive force acting on unilateral stiffener [9.4.(3)]
- Stiffener resistance for bending in the plane perpendicular to web
[9.4.(3)]

Stiffener 1
Point x = 2.92 m
ATTENTION! According to the (5.63) formulae it is not necessary to check a stiffener subjected to buckling.
Point x = 3.07 m
Stiffener 2
ATTENTION! According to the (5.63) formulae it is not necessary to check a stiffener subjected to buckling.

STABILITY OF COMPRESSIVE FLANGE (EC3 art. 8.1)


Symbols:
k
Aw
Afc

- Factor depending on section class


- Area of stiffener
- Area of compressive flange

k = 0.30
Aw = 2324 mm2
Check condition: (8.1)
D/tw = 47.43 < k(E/fyf)*[Aw/Afc]^0.5 = 317.23

[8.(1)]
[8.(1)]
[8.(1)]
Afc = 1660 mm2
OK!

Analyzed beam meets the Eurocode 3 requirements