Standardised Data centres

Sales presentation

Standardised Data Centres

Motivation

ll

Change of paradigm

lll

Rittals Data centre concept

lV

Benefits

Summary

Sales presentation

Standardised Data Centre


Motivation

Does every data centre really have to be unique?

Sales presentation

Standardised Data Centre


Motivation
50 years of customised, client-specific Data centres

Data Centre EC1020


Humboldt University 1965

Data Centre Google


Douglas County

Data Centre TR440


University Wrzburg 1979

Data Centre 1&1


Lenexa/Kansas (40.000 Server)

Sales presentation

Standardised Data Centre


Motivation

Data Center usually have a homogeneous, modular structure

Sales presentation

Standardised Data Centre

Motivation

ll

Change of paradigm

lll

Rittals Data centre concept

lV

Benefits

Summary

Sales presentation

Standardised Data Centre


Change of paradigm

Data centre construction

Component-based

Data Center module-based

Standardized Data centre


construction

Individual Data centre


construction
Customised Data Centre
Tailored Data Center solutions

Standardised Data Centre


Pre-defined Data Centre modules

Sales presentation

Standardised Data Centre

Motivation

ll

Change of paradigm

lll

Rittals Data centre concept

lV

Benefits

Summary

Sales presentation

RiMatrix
S
Standardised
Data Centre
Paradigmenwechsel
Rittals Data centre concept
The new RiMatrix S.
The revolutionary alternative to customised Data Centre construction.
Standardised products available off the shelf.

Sales
Sales presentation
presentation
Sales presentation

11

Standardised Data Centre


Rittals Data centre concept
RiMatrix

RiMatrix S

Individual products: LCP, UPS


Tailored data centre planning

Pre-defined Data Centre modules


Standardised Data Centre
planning

Every Data Center is unique

All Data centres have the same


structure

Pay as you grow


Client-specific solutions
Custom configurations
Product-specific service

Latest technology

ROI can be calculated


Simplified administration
Simplified service
Short delivery and launchtime

The Data Centre is a


standardised product

Sales presentation

12

RiMatrix S Technology
Mechanics What does this involve: using the Single6 as an
example?
Ready-for-connection
Power
technology/UPS

Power distribution

Electrical performance: 60 kW redundant


Separate climate areas:
IT area
Technical area

19" rack system

Usable U: 294

Pre-configured
Monitoring

Climate control
technology

Three shells:
Standard room
Standard security room
Standard container

Dimensions: L x W x H 7,000 x 2,750 x 2,710 mm = 19.25 m

Cooling output: 60 kW redundant

Cold aisle
containment

Integrated partitions

Fire
detection/fire
extinguishing

Base system

Cable duct
system

PM-IT / RiMatrix S Expert Training - Technology / 062014

13

RiMatrix S Technology
Mechanics Base configuration and most important variants
Single versions
Internal dimensions L x W x H
7,000 x 2,750 x 2,710 mm

Single 6, 60 kW n+1

Single 9, 90 kW n+1

Double versions
Internal dimensions L x W x H
7,000 x 4,776 x 2,710 mm

Double 6, 120 kW n+1

Double 9, 180 kW n+1

PM-IT / RiMatrix S Expert Training - Technology / 062014

14

Standardised Data Centre


Rittals Data centre concept
RiMatrix S (Module Single 6)
Space-saving climatization in the
raised-floor
Two separate microclimate zones
for IT and technology
Consistent separation of cold air
intake and warmer exhaust air
Cable routes at the top

6 server racks, 1 network rack


UPS, battery rack and distribution
enclosure
At double 6, the second module is
a mirror image

Sales presentation

15

Standardised Data Centre


Rittals Data centre concept
RiMatrix S (Module Single 9)
When using a central UPS
One microclimate zone for the
server area

Aisle containment
Raised floor
Climate control in the raised floor
Cable routes at the top

8 server racks, 1 server-/ network


rack
Distribution enclosure
At Double 9, the second module is
a mirror image

Sales presentation

16

Standardised Data Centre


Rittals Data centre concept
RiMatrix S
Consistent arrangement of all
cooling components in the Zero-USpace of the Data centre the
raised floor
Optimum air routing with minimum
deflections
All components are arranged
uncompromisingly according to
physical principles at the optimum
position in the cooling circuit of the
data centre around the heart the
server

Sales presentation

17

RiMatrix S Technology
Mechanics

Base system

Standard raised floor system


Height: 510 mm
Modular dimensions: 600 x 600 mm
Supporting load: 6 kN
ZUCS in raised floor
Half rack assembly
Same raised floor in Standard Room,
Standard Security Room and Container

Side view

Raised floor layout

PM-IT / RiMatrix S Expert Training - Technology / 062014

18

RiMatrix S Technology
Mechanics

Base system

Raised floor

Warm aisle
grating
Normal raised floor
plates

Ventilation duct for


air/water heat
exchanger
(ZUCS)

Grating
cold aisle
with fan

PM-IT / RiMatrix S Expert Training - Technology / 062014

19

RiMatrix S Technology
Climate control Internal/external principle
ZUCS in RiMatrix S

Pipework

Climate control
technology

Cold water supply

Exterior:
cooling container
or
provided on site
(existing or supplied)

PM-IT / RiMatrix S Expert Training - Technology / 062014

20

RiMatrix S Technology
Climate control Cooling container (70 kW, 100 kW)

Climate control
technology

Air-cooled
chiller 70 kW

Free cooler 70kW


Hydraulic
station

PM-IT / RiMatrix S Expert Training - Technology / 062014

21

RiMatrix S Technology
Climate control Cooling container (70 kW, 100 kW)

Climate control
technology

Integrated switchgear /
pump station
Switchgear
and
control

RiMatrix S service
commitment

PM-IT / RiMatrix S Expert Training - Technology / 062014

22

RiMatrix S Technology
Climate control Cooling container (70 kW, 100 kW)

Climate control
technology

Prototype pictures

Main components

Free cooler
Chiller
Switchgear
Pump station

PM-IT / RiMatrix S Expert Training - Technology / 062014

23

RiMatrix S Technology
Power distribution principle
Server enclosures, each 1 x PDU
phase A + 1 x PDU phase B

Power
distribution

Network enclosure,
1 x PDU phase A +
1 x PDU phase B

UPS + battery
enclosure

Power distribution
enclosure

Main power supply


provided by the
customer

PM-IT / RiMatrix S Expert Training - Technology / 062014

24

RiMatrix S Technology
Power distribution principle
Power
distribution

PDU 7955.132: 24x C13 + 6x C19, 3-phased, 16 A

PM-IT / RiMatrix S Expert Training - Technology / 062014

25

RiMatrix S Technology
Option: Efficiency package

Monitoring

Additional monitoring and measurement option

The efficiency package extends the monitoring and management functions of


the RiMatrix S

More components with measuring functions:


Metered PDU
Universal power measurement system
DCIM Software RiZone

The connection of third-party components is


carried out via RiZone

The characteristics for automation are defined:


Workflow-editor, alarm management, reports
Connection to IT or building service management /
industrial management systems

PM-IT / RiMatrix S Expert Training - Technology / 062014

26

RiMatrix S Technology
Option: Efficiency package

Monitoring

Measurement points
Water in
temperature
[C]

Server out
temperatures
[C]

Flow rate
[l/min]

IT load [kW]

Fan speed [%]

Infrastructure
load [kW]

Server in
temperatures
[C]

Total load [kW]

PM-IT / RiMatrix S Expert Training - Technology / 062014

27

RiMatrix S Technology
Security Shells
Protection
classes

Standard room

Standard security
room

Standard container

Fire protection

EI 90 / F90

EI 30

Shock test

3.000 Nm energy after


30 minutes inflame

Water and dusttightness

IP 56

IP 55

Acrid gas-tightness

Yes, based on EN
1634-3

Vandalism /
resistance class

WK II

RC II

EMC

Basic EMC protection

Basic EMC protection

PM-IT / RiMatrix S Expert Training - Technology / 062014

28

Standardised Data Centre


Rittals Data centre concept
RiMatrix S

The Data Centre modules have a complete, measured and TUV-confirmed


data sheet

Guaranteed partial PUE when using the Rittal cooling and control
Partial PUE 1.09.. 1.2 achieved with aid of:
Water inlet:

20 C

Server intake air:

26 C

Fan speed:

< 61 %

Delta T (air side): <18 K

Sales presentation

29

RiMatrix S Technology
Option: Efficiency package

Monitoring

Additional monitoring and measurement option

The efficiency package extends the monitoring and management functions of


the RiMatrix S

More components with measuring functions:


Metered PDU
Universal power measurement system
DCIM Software RiZone

The connection of third-party components is


carried out via RiZone

The characteristics for automation are defined:


Workflow-editor, alarm management, reports
Connection to IT or building service management /
industrial management systems

PM-IT / RiMatrix S Expert Training - Technology / 062014

30

RiMatrix S Technology
Option: Efficiency package

Monitoring

Measurement points
Water in
temperature
[C]

Server out
temperatures
[C]

Flow rate
[l/min]

IT load [kW]

Fan speed [%]

Infrastructure
load [kW]

Server in
temperatures
[C]

Total load [kW]

PM-IT / RiMatrix S Expert Training - Technology / 062014

31

Standardised Data Centre


Rittals Data centre concept
RiMatrix S
All RiMatrix S modules may be
scaled to almost any output
between 20 and 450 kW

The Container solution is limited to


scaling with the Single 6 and Single
9 modules, due to the spacial
conditions inside the containers.

Sales presentation

32

Standardised Data Centre


Rittals Data centre concept
RiMatrix S
One solution for existing property, security room and container

Sales presentation

33

Standardised Data Centre


Rittals Data centre concept
RiMatrix S
One item number for
RiMatrix S in existing
properties.

Single 6
Double 6
Single 9

Double 9

Sales presentation

34

Standardised Data Centre


Rittals Data centre concept
RiMatrix S
One item number for
RiMatrix S in security rooms
and containers.

Single 6
Double 6

Single 9
Double 9

Sales presentation

35

Standardised Data Centre


Rittals Data centre concept
RiMatrix S
Flexibility with optional packages

A few intelligent optional packages ensure the flexibilty at customer projects:

Efficiency package RiZone (Data Centre Infrastructure Management


Software), PDU (Power Distribution Unit), UMG (universal measuring
device) in ISV (distribution enclosure)

Redundant infeed for extend to TIER III for TV-certification

VESDA extinguishing system

Humidification and dehumidification for container-based version using in


critical climate zones

Sales presentation

36

Standardised Data Center

Motivation

ll

Change of paradigm

lll

Rittals Data centre concept

lV

Benefits

Summary

Sales presentation

Standardised Data Center


Benefits

What are the buying factors?

Costs

Time
Client

Quality

Service
Sales presentation

38

Standardised Data Center


Benefits
Cost benefits

Significantly simplified, shortened planning phase

Lower planning and implementation phase investments

Lower operating costs

Lower personnel costs

Simplified service- and administration processes

Sales presentation

39

Standardised Data Center


Benefits
Time benefits

Shortened planning time

Very short delivery time

Quick to go-live

Hotline

Service response time

Sales presentation

40

Standardised Data Center


Benefits
Quality benefits

Solution based on proven standard products

Fully documented

Certificates and approvals

Testing and acceptance tests

System tests

Sales presentation

41

Standardised Data Center


Benefits
Service benefits

Professional advice in quotation phase

Support during configuration, design and integration

Project manager/build manger during installation/going live

Service/fast response times/quick build times/availability of replacement


parts

Sales presentation

42

Standardised Data Center


Benefits
RiMatrix S service commitment

Product

Process

With a turnkey solution, the client also expects turnkey processes throughout the
project!

Sales presentation

43

Standardised Data Center

Motivation

ll

Change of paradigm

lll

Rittals Data centre concept

lV

Benefits

Summary

Sales presentation

Standardised Data Center


Summary
The facts at a glance
Data centres can be built from standardised modules

This applies for container and security rooms, but also for existing property
(buildings)
The Data centre is a product with one item number
The Data centre has a data sheet, The PUE and power consumption are
predictable
Complete ROI calculation can be made in the planning
All processes are simplified, so that the data centre is delivered and
commissioned in next to no time

Sales presentation

45

IT goes IE
RiMatrix S reference
RiMatrix S
Wollschlger Group buys off-the-peg data centre
The Wollschlger Group, one of
Germany's leading commercial enterprises
in the precision tools business.

Customer-Feedback :
To avoid long planning phases, we rely on the new concept for the standardised Rittal
data centre construction, says Stefan Wrder, Head of IT and Project Management at
Wollschlger. We were impressed by the functions of RiMatrix S and found that it was
exactly the right solution for Wollschlger. It completely fulfilled our requirements for both
energy efficiency and high availability, as well as for our future expansion opportunities.

Sales presentation