Contenido
INTRODUCCION................................................................................................... 3
DISEO DE COLUMNAS........................................................................................ 4
COLUMNAS...................................................................................................... 4
ESBELTEZ........................................................................................................ 5
EFECTOS LOCALES DE ESBELTEZ...................................................................5
EFECTOS GLOBALES DE ESBELTEZ.................................................................7
DISEO.......................................................................................................... 10
DISEO POR FLEXOCOMPRESION.................................................................10
HIPOTESIS DE DISEO................................................................................. 10
DISEO POR FLEXOCOMPRESION UNIAXIAL................................................10
DIAGRAMA DE INTERACCION......................................................................10
CONSTRUCCION DEL DIAGRAMA DE INTERACCION......................................10
LIMITES EN EL DIAGRAMA DE INTERACCION PARA EFECTOS DE DISEO.......12
USO DE ABACOS CON DIAGRAMAS DE INTERACCION...................................13
DISEO EN FLEXOCOMPRESION BIAXIAL.....................................................14
DISEO BIAXIAL SEGUN LA NORMA PERUANA.............................................14
LIMITES DEL REFUERZO PARA ELEMENTOS EN COMPRESION........................15
LIMITES
INTRODUCCION
Las columnas son miembros verticales a compresin de los marcos estructurales, que
sirven para apoyar a las vigas cargadas. Trasmiten a las cargas a los pisos superiores hasta
la planta y despus al suelo, a travs de la cimentacin. Puesto que las columnas son
elementos a compresin, la falla de una columna en un lugar crtico puede causar el
colapso progresivo de los pisos concurrentes y el colapso total ltimo de la estructura
completa.
La falla estructural de una columna es un evento de principal importancia. Es por esto que
debe de tener cuidado extremo en el diseo de las columnas, que deben tener una reserva
de resistencia ms alta que las vigas o cualquier otro elemento estructural horizontal,
especialmente porque las fallas de compresin proporcionan muy poca advertencia visual.
El reglamento ACI requiere que en el diseo de miembros a compresin se utilicen
factores de la resistencia , considerable menores que los factores para la flexin. El
cortante o la torsin.
En el caso de las vigas, la cantidad de refuerzo se controla para obtener un
comportamiento de falla dctil. En el caso de columnas, ocasionalmente dominara la carga
axial momento flexinante.
A medida que la carga en una columna se incrementa, el agrietamiento se intensifica en los
lugares de los amarres transversales, en toda su altura. En el estado lmite de falla, el
recubrimiento de concreto de las columnas con estribos o la capa de concreto que cubre los
espirales de la columna confinadas con espirales, se desprende y las varillas longitudinales
individuales , en las partes sin soporte entre los estribos . Se debe notar que en el estado
lmite de falla, el recubrimiento de concreto del refuerzo se desprende primero antes de
que se destruya la adherencia.
DISEO DE COLUMNAS
COLUMNAS
Las columnas son elementos que sostienen principalmente cargas a compresin. En
general, las columnas tambin soportan momentos flectores con respecto a uno o a los dos
ejes de la seccin transversal y esta accin puede producir fuerzas de tensin sobre una
parte de la seccin transversal.
Es por eso que en este trabajo se realizaran los diseos teniendo en cuenta diferentes
condiciones de diseo como columnas de tipo cortas con carga axial y un porcentaje de
diez, para el momento a la flexin; as haciendo la columna con momento an ms segura.
En el estudio de la flexin del concreto armado se introdujo el concepto de seccin
transformada fisurada y para ello se utiliz el ejemplo de las columnas cargadas
axialmente. El lector debe revisar nuevamente este concepto para entender la metodologa
de trabajo en el diseo de columnas de concreto armado. De la revisin de los temas
anteriores se concluye que: la resistencia de una columna cargada axialmente se determina
de ecuacin 9.1, con la inclusin de un factor de reduccin de resistencia . Los
factores que afectan la resistencia de las columnas son ms bajos que los de vigas ya que
las columnas, a diferencia de estas, son parte vital de la estabilidad de una estructura (la
falla de una viga es localizada y no produce colapso de la estructura, por el contrario la
falla de una columna la afecta parcial o totalmente con una alta posibilidad de colapso).
ESBELTEZ
(l)
: que afectan
individuales.
l =
Cm
1 - Pu
Pc
1.0
96
Dnde:
95
Pc = 2 E I
ln2
Si existen cargas laterales entre los apoyos del elemento Cm = 1, en caso
contrario :
Cm = 0.6 + 0.4 M1 / M2 > 0.4
( Ec Ig / 5 ) + Es
Ise
IE=
conservadoramente:
( 1 + d )
Ec Ig
2.5
( 1 + d )
IE=
Donde:
M1 : Momento flector menor de diseo en el extremo, es positivo si el
elemento est flexionado en curvatura simple y negativo si est
flexionado en doble curvatura.
M2 : Momento flector mayor de diseo en el extremo, es positivo siempre.
d : Relacin entre momento mximo de carga muerta y el momento mximo
de carga axial.
Ig
: Inercia de la seccin total no agrietada del concreto.
Ise
: Inercia del acero de refuerzo respecto al eje centroidal de la seccin.
Los efectos locales de esbeltez pueden ser despreciados si : ln/r es menor que 34
-12 M1/M2.
In
r
Ln
(cm)
270
r
(cm)
12
Ln/r
22.50
yy
260
18
21.67
Como se podr ver en los resultados del anlisis vertical, siempre habr
curvatura doble en los elementos, por lo que M1 va a ser negativo, por consiguiente el
miembro de la derecha siempre va a ser mayor que 34, por lo que se puede despreciar
los efectos locales de esbeltez.
g =
1
1-Q
B)
g =
Cm
1 - Pu
Pc
u
: deformacin relativa entre el nivel superior y el inferior del entrepiso
considerado, debido a las fuerzas laterales amplificadas y calculadas de acuerdo al anlisis
elstico de primer orden. Para el caso de las fuerzas laterales del sismo, u deber
multiplicarse por el factor de reduccin por ductilidad considerado en la determinacin de
estas fuerzas.
Cm
= 1
98
Pc =
(k . ln )2
2 E I
[Escriba aqu]
Donde:
EI
K
Pu
(ton)
u
(m)
Vu
(ton)
h
(m)
Qx
914.59
0.005373
131.43
3.20
0.047
1.000
1870.66
0.005856
244.26
3.20
0.056
1.000
2826.81
0.006272
343.36
3.20
0.065
1.069
3782.81
0.006574
428.74
3.20
0.073
1.078
4738.89
0.006641
500.38
3.20
0.079
1.085
5694.96
0.006368
558.29
3.20
0.081
1.088
6651.04
0.005653
602.48
3.20
0.078
1.085
7607.11
0.004383
532.94
3.20
0.066
1.070
8583.13
0.002586
650.10
3.90
0.035
1.000
NIVEL
Pu
(ton)
u
(m)
Vu
(ton)
h
(m)
Qy
1126.03
0.004295
155.44
3.20
0.039
1.0
2318.88
0.004484
288.88
3.20
0.045
1.0
3411.74
0.004586
406.08
3.20
0.050
1.0
4704.59
0.004590
507.04
3.20
0.053
1.0
5897.45
0.004436
591.78
3.20
0.055
1.0
7090.30
0.004088
660.28
3.20
0.055
1.0
8283.15
0.003503
712.54
3.20
0.051
1.0
9476.01
0.002650
748.57
3.20
0.042
1.0
10692.79
0.001636
768.87
3.90
0.023
1.0
DISEO
DISEO POR FLEXOCOMPRESION
En elementos sujetos a flexo compresin con cargas de diseo Pn menores a 0.1f
c Ag Pb (la menor), el porcentaje de refuerzo mximo proporcionado debe cumplir con
lo indicado para elementos sometidos a esfuerzos de flexin pura. Siendo Pb la resistencia
nominal a carga axial en condiciones de deformacin balanceada, como se ver ms
adelante.
HIPOTESIS DE DISEO
El diseo de un elemento sometido a flexo compresin se hace en base a las mismas
hiptesis de diseo en flexin, considerando adicionalmente el problema de esbeltez.
DISEO POR FLEXOCOMPRESION UNIAXIAL
Toda seccin sujeta a flexo compresin se disear de manera que siempre la combinacin
de esfuerzos actuantes, sea menor que las combinaciones de momento flector y carga axial
resistentes, representadas en un diagrama de interaccin.
DIAGRAMA DE INTERACCION
Si se analiza una seccin transversal sometida a flexo compresin, para una determinada
distribucin de acero, se puede obtener diferentes valores de Carga y Momento resistentes,
conforme se vare la posicin del eje neutro. A la curva que indica esta resistencia, teniendo
como ordenada la Carga Axial y como abscisa el Momento, se le denomina Diagrama de
Interaccin.
Para su construccin bastar analizar el equilibrio de la seccin variando la ubicacin del eje
neutro.
CONSTRUCCION DEL DIAGRAMA DE INTERACCION
Si se tiene que el momento es nulo, el valor de la carga axial, es mxima y se denomina Po
(ver figura 7.1). Esta se obtiene considerando la carga mxima del concreto y del acero
longitudinal colocado en el elemento. As tenemos:
Po = [0.85 fc Ac + As fy]
Donde:
= 0.70
Para columnas con estribos.
= 0.75
Po
0.85 fc
Esfuerzos
fy
As3
As2
x1
x2
y=0.0021
x2
fs3=fy
s2
s1
c= 0.003
fs2
0.85fc
fs1 = fy
Cc
( a = 1. c )
fs1 = fy
s2 < y = 0.0021
fs2
fs3 = fy
Tenemos que
F s2 = s2 Es As2
- Fierro del extremo en traccin As3:
Asumimos que s3 = y = 0.0021
F s3 = 4200 As3
s2 Es As2 (0)
1
Pnx
1
Pny
1
Pno
Donde:
Pu
= R e s i s t e n ci a ltima en flexin biaxial
Pnx = R e s i s t e n ci a de diseo para la misma columna bajo la
accin de momento nicamente en X ( ey = 0 ).
Pnx = R e s i s t e n ci a de diseo para la misma columna bajo la
accin de momento nicamente en Y ( ex = 0 ).
Pno = R e s i s t e n ci a de diseo para la misma columna bajo la
accin de carga axial nicamente (ex = ey = 0 ).
Esta ecuacin es vlida para valores de ( Pu/ Pno ) 0.1 ; para valores
menores a 0.1 la ecuacin pierde aproximacin, por lo cual la Norma
recomienda la siguiente expresin:
Mux
Mnx
Muy
Mny
Los requisitos de esta seccin son aplicables si la carga de diseo Pn excede de 0.1
fc Ag Pb (la menor). En caso contrario, el elemento deber cumplir los
requisitos para elementos en flexin.
La resistencia especfica del concreto (fc) no ser menor que 210 kg/cm2.
La calidad del acero de refuerzo no exceder de lo especificado para acero ARN
420.
El ancho mnimo de las columnas ser de 25 cm.
La relacin de la dimensin menor a la mayor de la seccin transversal de la columna
no ser menor que 0.4.
La cuanta de refuerzo longitudinal no ser menor que 0.01 ni mayor que 0.06.
Cuando la cuanta exceda 0.04 los planos debern incluir detalles constructivos de la
armadura en la unin viga columna.
La resistencia a la flexin de las columnas debern satisfacer la ecuacin:
Mnc > 1.4 Mnv
Donde:
Mnc : Es la suma de momentos, al centro del nudo
correspondiente a la resistencia nominal en flexin de las columnas que
forman dicho nudo.
Mnv : Es la suma de momentos, al centro del nudo
correspondiente a la resistencia nominal en flexin de las vigas que
forman dicho nudo.
El objetivo de esta exigencia es que las columnas tengan una mayor capacidad resistente en
flexin que las vigas concurrentes en el nudo, para asegurar que las rtulas plsticas se
formen en las vigas y no en las columnas.
Sin embargo en estructuras conformadas por mixtos de prticos y muros de corte
importantes, esta exigencia ya no es tan importante, pues los muros controlan la
deformacin lateral de la edificacin.
DISEO POR CORTE
Siguiendo el mismo criterio de buscar una falla por flexin en lugar de una por corte, la
fuerza cortante (Vu) de los elementos en flexo compresin deber determinarse a partir de
la resistencias nominales en flexin (Mn), en los extremos de la luz libre del elemento,
asociadas a la fuerza axial Pu que d como resultado el mayor momento nominal posible.
Debern colocarse en ambos extremos del elemento estribos cerrados sobre una
longitud, medida desde la cara del nudo (zona de confinamiento) que no sea menor que:
a) Un sexto de la luz libre del elemento.
b) La mxima de la seccin transversal del elemento.
c) 45 cm.
Estos estribos tendrn un espaciamiento que no debe exceder del menor de los
siguientes valores, a menos que las exigencias de diseo por esfuerzo cortante sean
mayores:
a) La mitad de la seccin ms pequea de la seccin transversal del elemento.
b) 10 cm. El primer estribo deber ubicarse a no ms de 5 cm. de la cara del nudo.
El espaciamiento del refuerzo transversal fuera de la zona de confinamiento, no
deber exceder de 16 veces el dimetro de la barra longitudinal de menor dimetro, la
menor dimensin del elemento 30 cm. a menos que las exigencias por diseo de esfuerzo
cortante sean mayores.
El rea mnima del refuerzo transversal que deber proporcionarse dentro del nudo,
deber cumplir con:
AV 7.0
b.s
fy
fc . bw . d (1 + 0.0071 +
Pu )
Ag
Vs
Av
fv
d
s
CUADRO DE COLUMNAS
CALIDAD EN LA CONSTRUCCINPgina 20
BIBLIOGRAFIA
CALIDAD EN LA CONSTRUCCINPgina 21
FIGURA 2
Curvas de esfuerzo en concreto y acero.